10.07.2015 Views

QLogic 8 Gb Intelligent Pass-thru Module for IBM BladeCenter ...

QLogic 8 Gb Intelligent Pass-thru Module for IBM BladeCenter ...

QLogic 8 Gb Intelligent Pass-thru Module for IBM BladeCenter ...

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

A12 – Command ReferenceSet Config ThresholdSet Config ThresholdSets the port alarm threshold parameters by which the I/O module monitors portper<strong>for</strong>mance and generates alarms. The changes you make with this commandare not retained when you reset or power cycle the I/O module unless you savethem using the Config Save command.AuthoritySyntaxAdmin session and a Config Edit sessionset config thresholdInitiates a configuration session by which to generate and log alarms <strong>for</strong> selectedevents. The system displays each event, its triggers, and sampling window oneline at a time and prompts you <strong>for</strong> a value. For each parameter, enter a new valueor press the Enter key to accept the current value shown in brackets. Table 12-15describes the port alarm threshold parameters.Table 12-15. Port Alarm Threshold ParametersParameterThreshold Monitoring EnabledCRCErrorsMonitoringEnabledDecodeErrorsMonitoringEnabledISLMonitoringEnabledLoginMonitoringEnabledLogoutMonitoringEnabledLOSMonitoringEnabledRising TriggerFalling TriggerSample WindowDescriptionMaster enable/disable parameter <strong>for</strong> all events.Enables (True) or disables (False) the generationof all enabled event alarms. The default is False.The event type enable/disable parameter. Enables(True) or disables (False) the generation of alarms<strong>for</strong> each of the following events:• CRC errors• Decode errors• ISL connection count• Device login errors• Device logout errors• Loss-of-signal errorsThe event count above which a rising trigger alarmis logged. The I/O module will not generateanother rising trigger alarm <strong>for</strong> that event until thecount descends below the falling trigger and againexceeds the rising trigger.The event count below which a falling trigger alarmis logged. The I/O module will not generateanother falling trigger alarm <strong>for</strong> that event until thecount exceeds the rising trigger and descendsagain below the falling trigger.The time in seconds in which to count events.59245-01 A 12-71

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!