Pumps11<strong>Compact</strong> <strong>hydraulic</strong> <strong>power</strong> <strong>packs</strong><strong>type</strong> <strong>HK</strong>, <strong>HK</strong>F, <strong>HK</strong>LBecause of the unique integrated fan configuration, the ”ready forconnection” <strong>hydraulic</strong> <strong>power</strong> <strong>packs</strong> are ideal for continuous operation.Another version for temperature sensitive applications features anauxiliary blower, thereby gaining improved cooling (approx. 25%).This <strong>type</strong> is available for single circuit operation (radial piston or gearpump), dual circuit operation (radial piston and/or gear pump) or triplecircuit operation (radial piston pump only). Both single and dual circuitpumps are also available as a horizontal version (<strong>type</strong> <strong>HK</strong>L).Complete <strong>hydraulic</strong> control systems canbe created by directly mounting variouscombinations of connection blocks andvalve banks to the <strong>hydraulic</strong> <strong>power</strong> pack.These <strong>hydraulic</strong> <strong>power</strong> <strong>packs</strong> are usedfor machine tools (lathes and millingmachines), jigs or general machineapplications, making a commonly usedexternal radiator superfluous.Nomenclature:Design:p max :Q max :Radial piston pump and/orgear pump withintegrated motor(Version for 3-phase mains)Oil immersed compact<strong>hydraulic</strong> <strong>power</strong> pack forpermanent and intermittentoperation (S1/S6 service)700 bar (radial piston pump)180 bar (gear pump)Radial piston pumpapprox. 13 lpm (high press.)(V g = 9.15 cm 3 /rev)Gear pump16 lpm (low pressure)(V g = 11.0 cm 3 /rev)V usable max :approx. 11.1 lBasic <strong>type</strong>s and general parametersBasic <strong>type</strong>and sizeStandard versionParameters: Delivery flow Q pu (lpm), approximate referencevalue and max. pressure P max (bar) with S 6 operation 1 )Radial piston pumpGear pumpSingle circuit pump:<strong>HK</strong> 24<strong>HK</strong> 33<strong>HK</strong> 34<strong>HK</strong> 43, <strong>HK</strong>F 43<strong>HK</strong> 44, <strong>HK</strong>F 44<strong>HK</strong>F 48Dual circuit pump:<strong>HK</strong> 44, <strong>HK</strong>F 44<strong>HK</strong>F 48Triple circuit pump:<strong>HK</strong> 44, <strong>HK</strong>F 44<strong>HK</strong>F 48Horizontal version:<strong>HK</strong>L 34, <strong>HK</strong>LW 34<strong>HK</strong>L 32, <strong>HK</strong>LW 32Q max H 0,46p max 700Q max H 1,25p max 560Q max H 1,25p max 700Q max H 2,08p max 610Q max H 2,08p max 700Q max H 0,9p max 700Q max H 0,83p max 700Q max H 1,65p max 700H 0,70570H 2,5270H 2,5440H 2,6470H 2,6650H 1,5700H 1,6500H 3,35560H 1,08380H 3,6190H 3,6310H 7,0180H 7,0250H 3,6350H 2,4350H 4,80390H 1,77220H 6,5100H 6,5170H 13,190H 13,1130H 6,5190H 4,4190H 8,70220Z 2,7170Z 2,7170Z 4,5170Z 4,5170Z 2,7170Z 2,7170Z 4,5160Z 4,5170Z 11,3110Z 11,3130Z 4,5170Z 4,5170Z 6,9100Z 6,9160Z 1680Z 16110Z 1690Z 11,31301) The parameterlisted here representonly a choicefrom a variety ofpossibilities.<strong>HK</strong>L 381.1-16 2009


<strong>Compact</strong> <strong>hydraulic</strong> <strong>power</strong> <strong>packs</strong>SymbolsSingle stage pump(radial piston pump,gear pump)Dual stage pump(radial piston/radial piston pump,(gear pump/gear pump, radial piston pump/gear pump)Triple circuit pump(only radial piston pump)Joint pump pedestalSeparate pump pedestalsSeparate pump pedestalsAdditional parameterBasic <strong>type</strong>Rev. ratingP NV usable maxNom. voltageand sizen N (rpm)(kW) 2 )(l)<strong>HK</strong> 2414000.550.853 + 230/400V /! 50 Hz 3 )<strong>HK</strong> 33, <strong>HK</strong> 33814100.81.45/2.93 + 500V ! 50 Hz<strong>HK</strong>L(W) 32(9), <strong>HK</strong>L(W) 328(9) 4 )28401.81.7/2.6 (8.2/9.1)<strong>HK</strong>L(W) 34(9), <strong>HK</strong>L(W) 348(9) 4 )<strong>HK</strong> 34, <strong>HK</strong> 348<strong>HK</strong> 36, <strong>HK</strong> 368<strong>HK</strong>(F) 43, (438, 435, 439)<strong>HK</strong>(F) 44, (448, 445, 449)<strong>HK</strong>(F) 485, (489, 482)<strong>HK</strong>L 38(9), <strong>HK</strong>L 388(9)14101400275014251410146014501.81.12.21.52.232.21.7/2.6 (8.2/9.1)1.45/2.91.45/2.92.4/4.6/1.8/5.52.4/4.6/1.8/5.51.8/5.5/11.11.7/2.6 (8.2/9.1)2 ) The actual <strong>power</strong> input is dependson the respective operation pressureand can be up to 1.5 x P N3 ) Also suitable for mains3 + 265/460V /! 60 Hz4 ) The motors of the single phaseversion (<strong>type</strong> <strong>HK</strong>LW) are availablefor 1 + 230V / 50 Hz and1 + 115V / 60 HzAdditional versions• Temperature and fluid level switches• Version with plug Co. HARTING• Version with additional leakage port (<strong>type</strong> <strong>HK</strong> 4.L)• Version with internal gear pump• Version with moulded motor• Various oil filler neck designs• Completion with connection block and valve banks(see also “Additional information”)Order examples<strong>HK</strong> 34 T/1 - H 3,6 - AS1/260 - BWN1F - H H5 R - 1 - 1 - G24<strong>Compact</strong> <strong>hydraulic</strong> <strong>power</strong> pack<strong>type</strong> <strong>HK</strong> 34 with temperatureswitch (coding T), radial pistonpump H 3,6, connection block(<strong>type</strong> A 1/260) with pressure limitingvalve (260 bar) and idle circulationvalve as well as directlymounted valve bank <strong>type</strong> BWN 1<strong>HK</strong> 44 /1 - H 2,5 - Z 6,9 - AS1/400 - AS1/110 - G24<strong>Compact</strong> <strong>hydraulic</strong> <strong>power</strong> pack <strong>type</strong> <strong>HK</strong> 44 with radial piston pump H 2,5and gear pump Z 6,9, pressure outlet on separate pump pedestals, twoconnection blocks (<strong>type</strong> AS1/..) with pressure limiting valve (400 barand 110 bar) and idle circulation valve (direct connection of valve bankspossible)20091.1-17


Pumps11DimensionsType <strong>HK</strong>..(illustrated version acc. to the example circuit on next page)Type <strong>HK</strong>L..Basic <strong>type</strong>H maxBTm (kg)<strong>HK</strong> 2434019619613<strong>HK</strong> 33, <strong>HK</strong> 3440521221220.5<strong>HK</strong> 3.849521221222.2<strong>HK</strong>L(W) 32, <strong>HK</strong>L(W) 3425136819619.2<strong>HK</strong>L(W) 3.825148619620.5<strong>HK</strong>L(W) 3.935850319622All dimensions in mm, subject to change without notice!<strong>HK</strong>L(W) 3.8935862119623.3<strong>HK</strong>(F) 43, <strong>HK</strong>(F) 4446024024029<strong>HK</strong>(F) 4.858024024034Pump pedestal 2<strong>HK</strong>(F) 4.963024024036Terminal box(only with <strong>type</strong> <strong>HK</strong> 4.)<strong>HK</strong>(F) 4.551324024030<strong>HK</strong>F 48283324024040Pumppedestal 1Additional information• <strong>Compact</strong>-<strong>hydraulic</strong> <strong>power</strong> <strong>packs</strong> <strong>type</strong> <strong>HK</strong>(F) 43 (44) D 7600-4<strong>type</strong> <strong>HK</strong> 33 (34) D 7600-3<strong>type</strong> <strong>HK</strong> 24 D 7600-2<strong>type</strong> <strong>HK</strong>L(W) D 7600-3L• Connection blocks <strong>type</strong> A D 6905 A/1<strong>type</strong> BD 6905 B<strong>type</strong> CD 6905 C• Directly mountable valve banks <strong>type</strong> VB D 7302<strong>type</strong> BWH(N) D 7470 B/1<strong>type</strong> BVZP 1 D 7785 B<strong>type</strong> SWR, SWS D 7450, D 7451, D 7951<strong>type</strong> BA D 7788• see also "Turn-key solutions from our modular system"• see also section "Devices for special applications"(Hydraulics for clamping, Devices for up to 700 bar)For section and page of the additionally listed devices,see <strong>type</strong> index1.1-18 2009


<strong>Compact</strong> <strong>hydraulic</strong> <strong>power</strong> <strong>packs</strong>Circuit example<strong>HK</strong>LW 32 DT/1 - HZ0,57/2,0- NA21F0-A700R/100/V120-WGZ4-1R-WG110Motor voltage 1 + 110V 60 HzNA21-F0-A700R/100/V120<strong>HK</strong> 448/1 - HH1,0/2,8 - H4,4 -- SS - A1/250 - BVZP1F - G22/0- D22/0- CZ2/180/5R- H15H17/20- WN1H/10/5 - 1 - 1- AS1/100 - V2/40 - BWN1F - H5H - 3651 - 1 - G24Motor voltage 3 + 400/230V 50 Hz !/Control circuit withthree speeds- 1 (-1-G24)- WN1H/10/5WGZ4-1R-WG110- H15H17/20<strong>HK</strong>LW32DT/1-HH8,8/5,7Control circuit with two pressure ratings- CZ2/180/5R- 3651 (-1-G24)H- D22/0- H5- BWN1F- G22/0- V2/40- BVZP1F- AS1/100- A1/250<strong>HK</strong>448/1 - HH1,0/2,8 - H4,4 - SS20091.1-19

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!