10.07.2015 Views

HVAC Pages 2-51 - Supco

HVAC Pages 2-51 - Supco

HVAC Pages 2-51 - Supco

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

GE Definite Purpose ContactorsFeatures/Benefits• Designed to control air conditioning, refrigeration and resistance heating loads.• Ranges: 20 to 90 Full Load Amps (FLA)• Poles: 1-1/2 to 3• Coil Voltages: 24, 120, 208/240 & 480• Universal mounting base allows easy replacement of other manufacturer’s devices(refer to SUPCO Contactor cross-reference).• Molded enclosed, replaceable coil structures.• Optional field installed auxiliary contacts available.Contactors®CR453C Series Coil Selection.Part No Digit 9 Denotes Coil VoltageCR453C Series20-to 40 Full Load Amps/ 1.5 & 2 polesFeatures• The coil and each power pole are suppliedwith two ¼” quick connect terminals.• Standard 20 – 30 FLA contactors featurehex screws with #2 Phillips / slottedheads.• Standard 40 FLA contactors include boxlugs.PART NO. DIGIT H A B FCOIL VOLTAGE 60 Hz 24 110-120 208-240 277COIL VOLTAGE 50 Hz 24 110-120 208-240 ***FULL RESISTIVE LRA SINGLE PHASE 50/60 HzPART LOAD AMPS 240/ COILNO. POLES AMPS PER POLE 277V 480V 600V VOLTAGECR453CB3HAA 1.5 25 35 150 125 100 24CR453CB3AAA 1.5 25 35 150 125 100 120CR453CB3BAA 1.5 25 35 150 125 100 208/240CR453CC3HAA 1.5 30 40 180 150 120 24CR453CC3AAA 1.5 30 40 180 150 120 120CR453CC3BAA 1.5 30 40 180 150 120 208/240CR453CA2HAA 2 20 30 120 100 80 24CR453CA2AAA 2 20 30 120 100 80 120CR453CA2BAA 2 20 30 120 100 80 208/240CR453CB2HAA 2 25 35 150 125 100 24CR453CB2AAA 2 25 35 150 125 100 120CR453CB2BAA 2 25 35 150 125 100 208/240CR453CC2HAA 2 30 40 180 150 120 24CR453CC2AAA 2 30 40 180 150 120 120CR453CC2BAA 2 30 40 180 150 120 208/240CR453CE2HBB 2 40 50 240 200 160 24CR453CE2ABB 2 40 50 240 200 160 120CR453CE2BBB 2 40 50 240 200 160 208/240CR453A Series25 to 0 Full Load Amps/ 3 PoleFeatures• 3 pole contactors• The coil and each power poleare supplied with two ¼” quickconnect terminals.• Standard 25 and 30 FLAcontactors feature hex screwswith #2 Phillips / slotted headsand short covers.• Standard 40 FLA contactorsinclude box lugs and longcovers.FULL RESISTIVE THREE PHASE 50/60Hz SINGLE PHASE 50/60 HzPART LOAD AMPS 240V 480V 600V HP@ HP@ COILNO. AMPS PER HP/LRA HP/LRA HP/LRAv 20V 24V VOLTAGECR453AB3HAA 25 35 7.5 / 150 10 / 125 10 / 100 2 3 24CR453AB3AAA 25 35 7.5 / 150 10 / 125 10 / 100 2 3 120CR453AB3CAA 25 35 7.5 / 150 10 / 125 10 / 100 2 3 480CR453AB3BAA 25 35 7.5 / 150 10 / 125 10 / 100 2 3 208/240CR453AC3HAA 30 40 10 / 180 15 / 150 15 / 120 2 5 24CR453AC3AAA 30 40 10 / 180 15 / 150 15 / 120 2 5 120CR453AC3CAA 30 40 10 / 180 15 / 150 15 / 120 2 5 480CR453AC3BAA 30 40 10 / 180 15 / 150 15 / 120 2 5 208/240CR453AD3HBB 40 50 10 / 240 20 / 200 20 / 160 3 7.5 24CR453AD3ABB 40 50 10 / 240 20 / 200 20 / 160 3 7.5 120CR453AD3CBB 40 50 10 / 240 20 / 200 20 / 160 3 7.5 480CR453AD3BBB 40 50 10 / 240 20 / 200 20 / 160 3 7.5 208/240CR453A Coil Selection.Part Number Digit 9 Denotes Coil Voltage*For other contactors, configurations and accessories, contact SUPCO.PART NO. DIGIT E H A B F C DCOIL VOLTAGE 60 Hz 12 24 110-120 208-240 277 460-480 575-600COIL VOLTAGE 50 Hz 12 24 110-120 208-240 *** 380-415 550-60077

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!