GE Definite Purpose ContactorsFeatures/Benefits• Designed to control air conditioning, refrigeration and resistance heating loads.• Ranges: 20 to 90 Full Load Amps (FLA)• Poles: 1-1/2 to 3• Coil Voltages: 24, 120, 208/240 & 480• Universal mounting base allows easy replacement of other manufacturer’s devices(refer to SUPCO Contactor cross-reference).• Molded enclosed, replaceable coil structures.• Optional field installed auxiliary contacts available.Contactors®CR453C Series Coil Selection.Part No Digit 9 Denotes Coil VoltageCR453C Series20-to 40 Full Load Amps/ 1.5 & 2 polesFeatures• The coil and each power pole are suppliedwith two ¼” quick connect terminals.• Standard 20 – 30 FLA contactors featurehex screws with #2 Phillips / slottedheads.• Standard 40 FLA contactors include boxlugs.PART NO. DIGIT H A B FCOIL VOLTAGE 60 Hz 24 110-120 208-240 277COIL VOLTAGE 50 Hz 24 110-120 208-240 ***FULL RESISTIVE LRA SINGLE PHASE 50/60 HzPART LOAD AMPS 240/ COILNO. POLES AMPS PER POLE 277V 480V 600V VOLTAGECR453CB3HAA 1.5 25 35 150 125 100 24CR453CB3AAA 1.5 25 35 150 125 100 120CR453CB3BAA 1.5 25 35 150 125 100 208/240CR453CC3HAA 1.5 30 40 180 150 120 24CR453CC3AAA 1.5 30 40 180 150 120 120CR453CC3BAA 1.5 30 40 180 150 120 208/240CR453CA2HAA 2 20 30 120 100 80 24CR453CA2AAA 2 20 30 120 100 80 120CR453CA2BAA 2 20 30 120 100 80 208/240CR453CB2HAA 2 25 35 150 125 100 24CR453CB2AAA 2 25 35 150 125 100 120CR453CB2BAA 2 25 35 150 125 100 208/240CR453CC2HAA 2 30 40 180 150 120 24CR453CC2AAA 2 30 40 180 150 120 120CR453CC2BAA 2 30 40 180 150 120 208/240CR453CE2HBB 2 40 50 240 200 160 24CR453CE2ABB 2 40 50 240 200 160 120CR453CE2BBB 2 40 50 240 200 160 208/240CR453A Series25 to 0 Full Load Amps/ 3 PoleFeatures• 3 pole contactors• The coil and each power poleare supplied with two ¼” quickconnect terminals.• Standard 25 and 30 FLAcontactors feature hex screwswith #2 Phillips / slotted headsand short covers.• Standard 40 FLA contactorsinclude box lugs and longcovers.FULL RESISTIVE THREE PHASE 50/60Hz SINGLE PHASE 50/60 HzPART LOAD AMPS 240V 480V 600V HP@ HP@ COILNO. AMPS PER HP/LRA HP/LRA HP/LRAv 20V 24V VOLTAGECR453AB3HAA 25 35 7.5 / 150 10 / 125 10 / 100 2 3 24CR453AB3AAA 25 35 7.5 / 150 10 / 125 10 / 100 2 3 120CR453AB3CAA 25 35 7.5 / 150 10 / 125 10 / 100 2 3 480CR453AB3BAA 25 35 7.5 / 150 10 / 125 10 / 100 2 3 208/240CR453AC3HAA 30 40 10 / 180 15 / 150 15 / 120 2 5 24CR453AC3AAA 30 40 10 / 180 15 / 150 15 / 120 2 5 120CR453AC3CAA 30 40 10 / 180 15 / 150 15 / 120 2 5 480CR453AC3BAA 30 40 10 / 180 15 / 150 15 / 120 2 5 208/240CR453AD3HBB 40 50 10 / 240 20 / 200 20 / 160 3 7.5 24CR453AD3ABB 40 50 10 / 240 20 / 200 20 / 160 3 7.5 120CR453AD3CBB 40 50 10 / 240 20 / 200 20 / 160 3 7.5 480CR453AD3BBB 40 50 10 / 240 20 / 200 20 / 160 3 7.5 208/240CR453A Coil Selection.Part Number Digit 9 Denotes Coil Voltage*For other contactors, configurations and accessories, contact SUPCO.PART NO. DIGIT E H A B F C DCOIL VOLTAGE 60 Hz 12 24 110-120 208-240 277 460-480 575-600COIL VOLTAGE 50 Hz 12 24 110-120 208-240 *** 380-415 550-60077