10.07.2015 Views

HVAC Pages 2-51 - Supco

HVAC Pages 2-51 - Supco

HVAC Pages 2-51 - Supco

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

ATFLATAdjustable AT Series• Series covers almost 95% of heater and dryer applications• Dial knob• 40° adjustable rangeAdjustable ThermostatsPART NO.STANDARD FLUSH ADJUSTABLEMOUNT MOUNT RANGE DIFFERENTIALAT012 FLAT012 135 175 20AT013 FLAT013 175 215 40AT014 FLAT014 210 250 40AT015 FLAT015 250 290 40Open on temperature riseThermostats• 1/4" quick connect terminals• Use 60T Electrical Ratings®Adjustable Airflow ThermostatsPART NO.STANDARD FLUSH ADJUSTABLEMOUNT MOUNT RANGE DIFFERENTIALAT021 FLAT021 90 130 20AT022 FLAT022 140 180 20Close on temperature riseSHFSHLFan Control* - Close on RisePART CUT CUTNO. DESCRIPTION OUT IN DIFFERENTIALSHF90 Fan 80 90 10SHF110 Fan 90 110 20SHF110DC Fan - Deep Cup 90 110 20SHF120 Fan 110 120 10SHF130 Fan 115 130 15SHF140 Fan 120 140 20SHF150 Fan 130 150 20SHF160 Fan 140 160 20SHF170 Fan 150 170 20SHF180 Fan 160 180 20SHF200 Fan 180 200 20SHF250 Fan 220 250 30*Adapter Flange Plate included with each thermostat.*Use 60T Electrical Ratings Page 44Limit Control* - Open on RisePART CUT CUTNO. DESCRIPTION OUT IN DIFFERENTIALSHL120 Limit - Open on Rise 120 110 10SHL140 Limit - Open on Rise 140 100 40SHL150 Limit - Open on Rise 150 110 40SHL160 Limit - Open on Rise 160 120 40SHL170 Limit - Open on Rise 170 130 40SHL180 Limit - Open on Rise 180 140 40SHL190 Limit - Open on Rise 190 150 40SHL200 Limit - Open on Rise 200 160 40SHL210 Limit - Open on Rise 210 130 80SHL230 Limit - Open on Rise 230 190 40SHL250 Limit - Open on Rise 250 210 40SHL300 Limit - Open on Rise 300 250 50SHL325 Limit - Open on Rise 325 275 50*Adapter Flange Plate included with each thermostat.*Use 60T Electrical Ratings Page 44Suspended Limit Thermostats (Terminal Suspended)RANGEPART No. DESCRIPTION OPEN°F CLOSE°F DIFF°F BRAND OEM NO.SAL105 Airflow Limit - Open on Rise 105 90 15 Janitrol B1340104SAL115 Airflow Limit - Open on Rise 115 100 15 Janitrol B1340101SAL120 Airflow Limit - Open on Rise 120 105 15 Janitrol B1340102SAL135 Airflow Limit - Open on Rise 135 120 15 GE 08-1912-0008-2399-00WP28X55Janitrol B1340103TOD 312547313611Direct Replacement ThermistorsPART NO. DESCRIPTION RANGE BRAND OEM NO.TH7001 Thermistor 1K @ 70°F Maytag 307208TH7010 Thermister 10K @ 70°F Maytag 306056Deep Cup Limit ThermostatsRANGEPART NO. OPEN°F CLOSE°F DIFF°F BRAND OEM NO.L135DC 135 120 15 Electrolux 5308013213L145DC 145 125 20 Electrolux 5308015847L210DC 210 170 40 Armstrong 018<strong>51</strong>A-02<strong>51</strong>8J3718<strong>51</strong>A18J3701*Use 60T Electrical Ratings Page 44<strong>HVAC</strong> Flush Mount Staging ThermostatsPARTNO. DESCRIPTION OPEN CLOSE DIFFERENTIALFL50 <strong>HVAC</strong> Staging Thermostat 50 35 15FL60 <strong>HVAC</strong> Staging Thermostat 60 45 154141

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!