Anue 5273 Net Tool Optimizer Specifications - messkom.de
Anue 5273 Net Tool Optimizer Specifications - messkom.de
Anue 5273 Net Tool Optimizer Specifications - messkom.de
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
<strong>Anue</strong> <strong>5273</strong> <strong>Net</strong> <strong>Tool</strong><br />
<strong>Optimizer</strong> <strong>Specifications</strong><br />
Service Provi<strong>de</strong>r <strong>Net</strong>work Visibility Systems<br />
for Advanced <strong>Net</strong>work Monitoring<br />
■ OVERVIEW<br />
Telecommunication and cable service provi<strong>de</strong>rs face many<br />
challenges monitoring and managing their operational<br />
networks. The <strong>Anue</strong> <strong>5273</strong>, a carrier class, NEBS Level<br />
3 compliant system, helps service provi<strong>de</strong>rs achieve<br />
optimal network performance while still meeting increased<br />
bandwidth needs required by growing mobile and vi<strong>de</strong>o<br />
content. This new addition to the 5200 family, aggregates<br />
data from multiple visibility points in a network and ensures<br />
that critical network traffic is always <strong>de</strong>livered to essential<br />
monitoring tools for complete network visibility. Enhancing<br />
the power of network monitoring tools improves network<br />
performance, increases operations’ team productivity and<br />
reduces potential risk of network outages. The <strong>Anue</strong> <strong>5273</strong><br />
can also be used in enterprise data centers where highavailability<br />
is essential.<br />
■ HIGH-AVAILABILITY FEATURES<br />
• NEBS Level 3 Compliant Product (without exceptions)<br />
• Redundant, Hot-Swappable Power Supply / Fan Modules<br />
• -48V DC or 120-240VAC Power Input<br />
• Front to Back Air Flow<br />
• Local and Remote Alarm Relay Support<br />
• Redundant Management Ports<br />
• Craft Interface for Emergency Out-of-Band Reset<br />
■ PERFORMANCE<br />
• 10 Mb to 10 Gb Ethernet support<br />
• Non-blocking architecture; 244Gb/s total bandwidth<br />
• Full line rate across all ports with filtering enabled<br />
• Port reconfiguration with no performance impact<br />
■ PORT FLEXIBILITY<br />
• Up to 28 ports available<br />
• Ports 1-20: 1Gb (SFP) or 10Gb (SFP+)<br />
• Ports 21-24: Up to 1Gb copper (RJ45)<br />
• Modular Ports 1-4: 1Gb SFP+, 10Gb CX-4,<br />
10Gb XFP or 10Gb SFP+<br />
• Ingress/Egress port programmability<br />
• Software port licensing<br />
• Flexible Port Interconnections with additional <strong>Anue</strong> 5200<br />
series products<br />
■ MANAGEMENT<br />
• SNMP v1, v2, v3 support<br />
• TACACS+ support (members and groups)<br />
• Granular access control features<br />
• Event logging<br />
• Syslog<br />
• IT Automation control<br />
• Dual IP based management ports (RJ45 – 10/100/1000)<br />
■ FILTERING<br />
• Centralized filter templates<br />
• Overlapping Filter Engine<br />
• Filter parameters (Layer 2-4)<br />
- MAC Source/Dest addresses<br />
- VLAN and Ethertypes<br />
- IP protocol and DSCP/TOS<br />
- Source/Dest IP (IPv4/IPv6)<br />
- UDP, TCP Ports<br />
WWW.ANUESYSTEMS.COM
Physical Specification<br />
■ SIZE AND WEIGHT<br />
• 2U high rack mountable enclosure<br />
• Dimensions: 17.3W x 18.3L x 3.35H (inches)<br />
• Weight: 19.0lb (8.6 kg)<br />
■ POWER AC<br />
• Input AC Voltage: 85-240 VAC RMS auto-switching<br />
• Frequency: 50-60Hz<br />
• Nominal power requirement: 2A @ 120 VAC, 230W<br />
• Maximum power requirement: 5A @ 85 VAC, 432W<br />
• Heat/Power Dissipation: 786 BTU/hr (typical)<br />
1475 BTU/hr (max)<br />
■ POWER DC<br />
• Operating input voltage: -36 to -75 VDC<br />
• Maximum operating input current: 13A @ -36 VDC, 397W<br />
• Nominal current: 3.6A @ -48V, 173W<br />
• Heat/Power Dissipation: BTU/hr (typical),<br />
1356 BTU/hr (max)<br />
Operating <strong>Specifications</strong><br />
Operational Environment<br />
■ TEMPERATURE<br />
• Operating: -5°C to 40°C<br />
• Short-term*: -5°C to 55°C (*not to exceed 96 hours)<br />
• Short-term* with fan failure: -5°C to 40°C (*not to<br />
exceed 96 hours)<br />
■ HUMIDITY<br />
• Operating: 5% to 85%, (non-con<strong>de</strong>nsing)<br />
• Short-term*: 5% to 90% (non-con<strong>de</strong>nsing, *not to<br />
exceed 96 hours)<br />
■ SHOCK AND VIBRATION<br />
• ETSI 300 019<br />
Regulatory/Safety<br />
North American Safety<br />
UL 60950-1, 2nd Edition<br />
CSA C22.2 No. 60950-1, 2nd Edition<br />
GR-1089-CORE, Issue 5, August 2009<br />
European Safety<br />
EN60950-1<br />
International Safety<br />
CB Scheme : IEC 60950-1:2005 First Edition<br />
North American Safety<br />
UL 60950-1, 2nd Edition<br />
CSA C22.2 No. 60950-1, 2nd Edition<br />
GR-1089-CORE, Issue 5, August 2009<br />
EMI/EMC<br />
North American EMC<br />
FCC part 15, Class A (USA)<br />
ICES-003 Issue 4, Class A (Canada)<br />
GR-1089-CORE, Issue 5, August 2009<br />
European EMC<br />
EN55022 2006 Class A (Emissions)<br />
EN55024 1998 w/A2 (Immunity)<br />
EN61000-3-2:2006(Harmonics)<br />
EN61000-3-3 1995 w/A2(Flicker)<br />
ETSI EN 300 386:2005-4<br />
IEC/International EMC<br />
IEC/EN 61000-4-2:2001 Electrostatic Discharge Immunity<br />
IEC/EN 61000-4-3:2006 Radiated Immunity<br />
IEC/EN 61000-4-4:2004 Transient/Burst Immunity<br />
EN61000-3-3 1995 w/A2(Flicker)<br />
IEC/EN 61000-4-5:2005 Surge Immunity<br />
IEC/EN 61000-4-6:2007 Conducted Radio Frequency<br />
Immunity<br />
IEC/EN 61000-4-11:2004 Voltage Dips, Interruptions and<br />
Variations<br />
North American Safety<br />
UL 60950-1, 2nd Edition<br />
CSA C22.2 No. 60950-1, 2nd Edition<br />
GR-1089-CORE, Issue 5, August 2009<br />
Environmental<br />
EN 300 019-2-3 (Operational Tests, Class T3.2)<br />
EN 300 019-2-2 (Transportation Tests, Class T2.3)<br />
EN 300 019-2-1 (Storage Tests, Class T1.2)<br />
GR-63-CORE, Issue 3, March 2006<br />
Inclu<strong>de</strong>d Accessories<br />
• AC power cord<br />
• USB flash drive with activation license key<br />
• Rack Mount Kit<br />
WWW.ANUESYSTEMS.COM
■ COMPLETE SYSTEMS<br />
ORDERING INFORMATION<br />
SYS-<strong>5273</strong>-ONE-DC DC Version - base system with five 1Gb SFP ports enabled<br />
SYS-<strong>5273</strong>-TEN-DC DC Version – base system with five 10Gb SFP+ ports enabled<br />
SYS-<strong>5273</strong>-ALL-DC DC Version - base system with all ports enabled<br />
• Inclu<strong>de</strong>s two MOD-P5200-X2D-PLUS<br />
SYS-<strong>5273</strong>-SPARE-DC SYS-<strong>5273</strong>-SPARE-DC - DC Version - cold spare system<br />
SYS-<strong>5273</strong>-ONE-AC AC Version - base system with five 1G SFP ports enabled<br />
SYS-<strong>5273</strong>-TEN-AC AC Version – base system with five 10G SFP+ ports enabled<br />
SYS-<strong>5273</strong>-ALL-AC AC Version - base system with all ports enabled<br />
• Inclu<strong>de</strong>s two MOD-P5200-X2D-PLUS<br />
SYS-<strong>5273</strong>-SPARE-AC AC Version - cold spare system<br />
■ OPTIONS, UPGRADES, & ACCESSORIES<br />
MOD-<strong>5273</strong>-ACMOD Additional AC power module (redundant)<br />
MOD-<strong>5273</strong>-DCMOD Additional DC power module (redundant)<br />
MOD-<strong>5273</strong>-FANMOD Additional Fan module<br />
ACC-<strong>5273</strong>-FILTER 1 year supply of air filters for the <strong>5273</strong> chassis (4x filters)<br />
■ 1 GIG COPPER LICENSES<br />
LIC-P5200-G1C 1Gb Copper, RJ-45 Port – 10/100/1000 Base-T, quantity One<br />
LIC-P5200-G4C 1Gb Copper, RJ-45 Ports – 10/100/1000 Base-T, quantity Four<br />
■ 1 GIG OPTICAL LICENSES<br />
LIC-P5200-G1D 1Gb SFP Port – quantity One<br />
LIC-P5200-G4D 1Gb SFP Ports – quantity Four<br />
LIC-P5200-G8D 1Gb SFP Ports – quantity Eight<br />
LIC-P5200-G15D 1Gb SFP Ports – quantity Fifteen<br />
■ 10 GIG OPTICAL LICENSES<br />
LIC-P5200-X1D 10Gb SFP+ Port – quantity One<br />
LIC-P5200-X4D 10Gb SFP+ Ports – quantity Four<br />
LIC-P5200-X8D 10Gb SFP+ Ports – quantity Eight<br />
LIC-P5200-X15D 10Gb SFP+ Ports – quantity Fifteen<br />
■ 1G TO 10G UPGRADE LICENSE<br />
LIC-P5200-X1D-UP Upgra<strong>de</strong> 1Gb SFP port to 10Gb/1Gb SFP+ port<br />
■ 1G MODULE CARDS<br />
MOD-P5200-G2D-PLUS<br />
LIC-P5200-PLUS-UP<br />
1Gb Optical SFP Ethernet Ports - quantity two. Upgradable to 10Gb SFP+ ports<br />
with the LIC-P5200-PLUS-UP. Ports can be used with SFP transceivers.<br />
Upgra<strong>de</strong> MOD-P5200-G2D-PLUS Plug-in module (2x ports) from 1G SFP to<br />
10Gb/1Gb SFP+<br />
WWW.ANUESYSTEMS.COM
■ 10G MODULE CARDS<br />
MOD-P5200-X2C<br />
MOD-P5200-X2O-X - 10G<br />
MOD-P5200-X2D-PLUS<br />
■ 1G SFP TRANSCEIVERS<br />
ORDERING INFORMATION<br />
10Gb Copper CX4 Ethernet Ports - quantity two. 10m distance. Transceivers<br />
integrated with port.<br />
10Gb Optical XFP Ethernet Ports - quantity two. Ports can be set as XFP-SR,<br />
and XFP-LR with transceivers<br />
10Gb or 1Gb Optical SFP/SFP+ Ethernet Ports - quantity two. Ports can be used<br />
with SFP or SFP+ transceivers<br />
MM850 1Gb SFP optical transceiver – SX 850nm (550 meters)<br />
SM1310 1Gb SFP optical transceiver – LX 1310nm (10km)<br />
CGI 1Gb SFP copper transceiver<br />
■ 10G SFP+ TRANSCEIVERS<br />
MM850-PLUS MM850-PLUS - 10G SFP+ optical transceiver – SR 850nm (300 meters)<br />
SM1310-PLUS 10Gb SFP+ optical transceiver – LR 1310nm (10km)<br />
■ 10G XFP TRANSCEIVERS<br />
XMM850-E 10Gb XFP Ethernet only optical transceiver – SR 850nm (300 meters)<br />
XSM1310 10Gb XFP optical transceiver – LR 1310nm (10km)<br />
© 2002-2011 <strong>Anue</strong> Systems Inc.<br />
<strong>Anue</strong> Systems <strong>5273</strong>DS 0511