Passive <strong>House</strong>-Workshop „URBAN VISIONS IN GUANGZHOU“<br />

„ENERGETIC RESTORATION OF EXISTING BUILDINGS<br />

... and their practical realization“<br />

Prof. Dipl.-Ing. Ludwig <strong>Rongen</strong><br />

architect + town planner BDA<br />

University of applied sciences FH Erfurt, Germany<br />

Visiting Professor Sichuan-University, Chengdu, V. R. China<br />

Visiting Professor Southwest Jiaotong University, Chengdu, V. R. China<br />

w w w . r o n g e n – a r c h i t e k t e n . d e


Field of research / Special experiences<br />

Energy efficiency in building (new building and restoration)<br />

Realisation of a lot of passive houses, e.g. the first old peoples home in<br />

passive house standard in Europe<br />

Series of publications about passive houses<br />

Series of lectures about passive houses<br />

w w w . r o n g e n – a r c h i t e k t e n . d e


Coauthor<br />

“Frick Knöll structural theory”<br />

w w w . r o n g e n – a r c h i t e k t e n . d e


Guestprofessorship<br />

Southwest Jiaotong University, Chengdu (China)<br />

Sichuan University, Chengdu (China)<br />

Home<br />

w w w . r o n g e n – a r c h i t e k t e n . d e


Membership<br />

Chamber of <strong>Architects</strong>, North Rhine-Westphalia<br />

Chamber of <strong>Architects</strong>, Thuringia<br />

German Confederation of <strong>Architects</strong> (BDA)<br />

Community of information of passive houses<br />

Steering communitee cluster “Energy efficiency and solar construction”<br />

Science forum “Energy efficiency in building”<br />

Executive “German – Chinese competencecenter building”<br />

w w w . r o n g e n – a r c h i t e k t e n . d e


w w w . r o n g e n – a r c h i t e k t e n . d e


w w w . r o n g e n – a r c h i t e k t e n . d e


WORKSHOP 2007<br />

w w w . r o n g e n – a r c h i t e k t e n . d e


RESIDENTIAL COMPLEX<br />

Reconstruction and alteration of a former garage from 1960 into a<br />

residential complex in passive house standard<br />

w w w . r o n g e n – a r c h i t e k t e n . d e


GRAPHICAL MODEL<br />

raised roof as timber construction in passive house standard<br />

w w w . r o n g e n – a r c h i t e k t e n . d e


BEFORE<br />

AFTERWARDS<br />

w w w . r o n g e n – a r c h i t e k t e n . d e


BEFORE<br />

AFTERWARDS<br />

w w w . r o n g e n – a r c h i t e k t e n . d e


BEFORE<br />

AFTERWARDS<br />

w w w . r o n g e n – a r c h i t e k t e n . d e


longitudinal section<br />

raised roof as a timber construction in passive house standard<br />

w w w . r o n g e n – a r c h i t e k t e n . d e


ICHNOGRAPHY RAISED ROOF<br />

flat 01<br />

flat 02<br />

w w w . r o n g e n – a r c h i t e k t e n . d e


DETAIL OF THE RAISED ROOF<br />

U- value roof = 0,100<br />

W/m²K<br />

U-Value exterior wall = 0,088 W/m²K<br />

w w w . r o n g e n – a r c h i t e k t e n . d e


thermal insulation the full complement of the rafters<br />

BUILDING SITE<br />

w w w . r o n g e n – a r c h i t e k t e n . d e


Energy consumption before alteration: 141,03 kWh/m²a<br />

Energy consumption after alteration : 13,10 kWh/m²a<br />

Energy saving 90,7% !<br />

and....increase of comfort!<br />

better lightness<br />

better hygiene<br />

Less movement of the air in the rooms<br />

w w w . r o n g e n – a r c h i t e k t e n . d e


afterwards<br />

before<br />

w w w . r o n g e n – a r c h i t e k t e n . d e


THE BUILDING PROJECT UNDER CONSTRUCTION<br />

w w w . r o n g e n – a r c h i t e k t e n . d e


CARITAS-HOUSE NEUWERK<br />

First old peoples home (80 residents) in passive house standard in Europe<br />

w w w . r o n g e n – a r c h i t e k t e n . d e


CARITAS-HOUSE NEUWERK – facades<br />

w w w . r o n g e n – a r c h i t e k t e n . d e


w w w . r o n g e n – a r c h i t e k t e n . d e


HOUSING TECHNOLIGY<br />

w w w . r o n g e n – a r c h i t e k t e n . d e


BUILDING SITE<br />

w w w . r o n g e n – a r c h i t e k t e n . d e


HEAT LOST<br />

EARNING HEAT<br />

HEAT REQUIREMENT<br />

YES!<br />

31,3<br />

26,0<br />

5,4<br />

kWh/m²a<br />

kWh/m²a<br />

kWh/m²a<br />

w w w . r o n g e n – a r c h i t e k t e n . d e


DINING HALL<br />

w w w . r o n g e n – a r c h i t e k t e n . d e


INTERIOR IMRPESSIONS<br />

w w w . r o n g e n – a r c h i t e k t e n . d e


DETAILS<br />

w w w . r o n g e n – a r c h i t e k t e n . d e


CARITAS-HOUSE NEUWERK by dawn and night<br />

w w w . r o n g e n – a r c h i t e k t e n . d e


MEDICAL CENTRE, MÖNCHENGLADBACH; GERMANY<br />

Alteration of a former residential home for female nursing students<br />

w w w . r o n g e n – a r c h i t e k t e n . d e


efore alteration<br />

w w w . r o n g e n – a r c h i t e k t e n . d e


The overhanging balconies had been<br />

great thermal bridges up to know<br />

The overhanging balconies will be<br />

integrated into the heated structural shell<br />

w w w . r o n g e n – a r c h i t e k t e n . d e


upper floor (medical practice)<br />

w w w . r o n g e n – a r c h i t e k t e n . d e


A SINGLE FAMILY HOUSE FROM 1961<br />

w w w . r o n g e n – a r c h i t e k t e n . d e


DETAIL OF THE CONTINUOUS ATTIC<br />

BEFORE ALTERATION<br />

w w w . r o n g e n – a r c h i t e k t e n . d e


DETAIL OF THE CONTINUOUS ATTIC<br />

AFTER ALTERATION<br />

ADDITIVELY THERMAL INSULATION<br />

OF THE EXTERIOR WALLS AND THE ROOF<br />

EXTERIOR WALLS FACED WITH NARROW<br />

GALZED LARCH TIMBER PANELS<br />

w w w . r o n g e n – a r c h i t e k t e n . d e


energy consumption before alteration<br />

255,00 kWh/m²a<br />

energy consumption after alteration<br />

82,51 kWh/m²a<br />

saving in energy consumption 67,6% !<br />

w w w . r o n g e n – a r c h i t e k t e n . d e


PASSIVEHOUSE-EXAMPLE – Varieties of design<br />

w w w . r o n g e n – a r c h i t e k t e n . d e


PASSIVEHOUSE-EXAMPLE – Varieties of design<br />

w w w . r o n g e n – a r c h i t e k t e n . d e


INTERIOR IMPRESSIONS<br />

w w w . r o n g e n – a r c h i t e k t e n . d e


PASSIVEHOUSE-EXAMPLE – Varieties of design<br />

w w w . r o n g e n – a r c h i t e k t e n . d e


PASSIVEHOUSE-EXAMPLE – Varieties of design<br />

w w w . r o n g e n – a r c h i t e k t e n . d e


economy<br />

by the example of the Caritas <strong>House</strong> Neuwerk (see above)<br />

w w w . r o n g e n – a r c h i t e k t e n . d e


calculation of profitability<br />

in comparison with a German standard house („low energy house“)<br />

additional costs in comparison with a „low energy house“<br />

about 229.000 €<br />

government grant 128.000 €<br />

grant aided bank credit by KfW-bank<br />

The building owner could have got a grant credit of 4.000.000 €, but he did not need it<br />

8.420 € annually (present value in Nov. 2001)<br />

47.000 €<br />

annually capital costs for bank credit (interest + paying off mortgage) 2.580 €/a<br />

annually saving costs of heating energy in comparison by a „low energy<br />

house“<br />

ca. 11.000 €/a<br />

From the beginning the saving costs of the Caritas <strong>House</strong> Neuwerk in comparison with a<br />

„low energy house“ amounts to<br />

w w w . r o n g e n – a r c h i t e k t e n . d e


In this calculation has been left out of consideration:<br />

Saving in energy consumption because of the very good blower door test (air tightness)<br />

(n 50 -value = 0,4 h -1 )<br />

Increase of energy costs between Nov. 2001 and Jan. 2008<br />

originally calculated saving costs: 8.420 € annually (present value Nov. 2001)<br />

n 50 = 0,4 h -1 > 11,9 % saving in energy consumption<br />

increase in energy costs between Nov. 2001 and Jan. 2008 > 121 %<br />

ACTUAL SAVING COSTS (present value March 2008):<br />

20.823 € annually<br />

11,9 %<br />

121 %<br />

9.422 € annually<br />

20.823 € annually<br />

w w w . r o n g e n – a r c h i t e k t e n . d e


Nov. 2001: calculated saving costs 8.420 € annually<br />

Jan. 2008: real saving costs<br />

20.823 € annually<br />

present value: 02.01.2008<br />

98,9 US $/Barrel<br />

present value: 04.11.2007<br />

92,5 US $/Barrel<br />

present value: 10.08.2006<br />

78 US $/Barrel<br />

present value: 30.07.2005<br />

60 US $/Barrel<br />

Quelle: www.tecson.de TECSON GmbH PRICE DEVELOPMENT OF CRUDE OIL<br />

w w w . r o n g e n – a r c h i t e k t e n . d e


<strong>House</strong> Hanssen Höppener<br />

<strong>Rongen</strong> <strong>Architects</strong><br />

w w w . r o n g e n – a r c h i t e k t e n . d e


w w w . r o n g e n – a r c h i t e k t e n . d e


w w w . r o n g e n – a r c h i t e k t e n . d e


w w w . r o n g e n – a r c h i t e k t e n . d e


w w w . r o n g e n – a r c h i t e k t e n . d e


EG OG<br />

w w w . r o n g e n – a r c h i t e k t e n . d e


Tag des Passivhauses<br />

w w w . r o n g e n – a r c h i t e k t e n . d e


<strong>House</strong> <strong>Engels</strong> <strong>Houben</strong><br />

<strong>Rongen</strong> <strong>Architects</strong><br />

w w w . r o n g e n – a r c h i t e k t e n . d e


w w w . r o n g e n – a r c h i t e k t e n . d e


w w w . r o n g e n – a r c h i t e k t e n . d e


w w w . r o n g e n – a r c h i t e k t e n . d e


EG OG<br />

w w w . r o n g e n – a r c h i t e k t e n . d e


<strong>House</strong> Dres. Sander<br />

<strong>Rongen</strong> <strong>Architects</strong><br />

w w w . r o n g e n – a r c h i t e k t e n . d e


w w w . r o n g e n – a r c h i t e k t e n . d e


w w w . r o n g e n – a r c h i t e k t e n . d e


w w w . r o n g e n – a r c h i t e k t e n . d e


w w w . r o n g e n – a r c h i t e k t e n . d e


w w w . r o n g e n – a r c h i t e k t e n . d e


w w w . r o n g e n – a r c h i t e k t e n . d e


w w w . r o n g e n – a r c h i t e k t e n . d e


w w w . r o n g e n – a r c h i t e k t e n . d e


w w w . r o n g e n – a r c h i t e k t e n . d e


w w w . r o n g e n – a r c h i t e k t e n . d e


Prof. Dipl.-Ing. Ludwig <strong>Rongen</strong><br />

architect +town planner BDA<br />

University of applied sciences, FH Erfurt, Germany<br />

Visiting Professor Sichuan-University, Chengdu, V. R. China<br />

Visiting Professor Southwest Jiaotong University, Chengdu, V. R. China<br />

THANK YOU FOR YOUR ATTENTION !<br />

Glockengasse 31<br />

99084 Erfurt<br />

Germany<br />

Fon: 004936/5615770<br />

Fax: 004936/5615771<br />

Propsteigasse 2<br />

41849 Wassenberg<br />

Germany<br />

Fon: 00492432/3094<br />

Fax: 0049/2432/4304<br />

RONGEN ARCHITEKTEN<br />

Dr.-Overhues-Allee 40<br />

52355 Düren<br />

Germany<br />

Fon: 0049/242/207461<br />

Fax: 0049/242/62654<br />

w w w . r o n g e n – a r c h i t e k t e n . d e

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!