General Data - Cooling Only (R22)MODELNOMINAL CAPACITYNOMINAL TOTAL INPUT POWERNOMINAL RUNNING CURRENTEERPOWER SOURCEREFRIGERANT TYPE / CONTROLINDOOR UNITOUTDOOR UNITBtu/hWWAW/WV/Ph/HzMMST101015A2 x MCK010C MCK015C31700 (9500 - 31700)9280 (2780 - 9270)3233 (1053 - 3233)14.91 (4.50 - 14.91)2.88220 ~ 240 / 1 / 50R22 / CAPILLARY TUBECONTROLAIR DISCHARGEOPERATION4 WAY AUTOMATIC LOUVER (UP & DOWN)WIRELESS OR WIRED MICROCOMPUTER REMOTE CONTROLAIR FLOWHIGHMEDIUMLOWL/s / CFML/s / CFML/s / CFM194 / 410184 / 390175 / 370EXTERNAL STATIC PRESSURE (H/M/L) Pa (in.wg.)N/ASOUND PRESSURE LEVEL (H/M/L)dBA 44 / 43 / 42 44 / 42 / 41UNIT DIMENSIONPACKINGDIMENSIONHEIGHTWIDTHDEPTHHEIGHTWIDTHDEPTHmm/inmm/inmm/inmm/inmm/inmm/in250 (295) / 9.8 (11.6)570 (640) / 22.4 (25.2)570 (640) / 22.4 (25.2)317 (127) / 12.5 (5).0630 (700) / 24.8 (27.6)630 (700) / 24.8 (27.6)UNIT WEIGHTkg/lb 22 + 2 / 49 + 4 23 + 2 / 51 + 4CONDENSATE DRAIN SIZEAIR FLOWSOUND PRESSURE LEVELmm/inL/s / CFMdBA19.1 / ¾1132.7 / 240061UNIT DIMENSIONPACKINGDIMENSIONHEIGHTWIDTHDEPTHHEIGHTWIDTHDEPTHmm/inmm/inmm/inmm/inmm/inmm/in632 / 24.9960 / 37.8437 / 17.2824 / 32.41,194 / 47.0611 / 24.1INDOOR UNITOUTDOOR UNITUNIT WEIGHTTYPEkg/lb63 / 138.9FLARE VALVEPIPE CONNECTIONREFRIGERANT CHARGESIZELIQUID mm/in3 x 6.35 / 3 x ¼GAS mm/in 2 x 9.52 / 2 x ⅜ 12.7 ½kg/lb 2 x 0.80 / 2 x 1.76 2 x 0.83 x 2 x 1.831) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW :a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1.4m BELOW FACIA.94

General Data - Cooling Only (R22)INDOOR UNITMMST101515AMODELOUTDOOR UNITMCK010C2 x MCK015CBtu/h34900 (9500 - 34900)NOMINAL CAPACITYNOMINAL TOTAL INPUT POWERNOMINAL RUNNING CURRENTEERPOWER SOURCEWWAW/WV/Ph/Hz10220 (2780 - 10220)3756 (1053 - 3756)16.72 (4.50 - 16.72)2.79220 ~ 240 / 1 / 50REFRIGERANT TYPE / CONTROLR22 / CAPILLARY TUBECONTROLAIR DISCHARGEOPERATION4 WAY AUTOMATIC LOUVER (UP & DOWN)WIRELESS OR WIRED MICROCOMPUTER REMOTE CONTROLAIR FLOWHIGHMEDIUMLOWL/s / CFML/s / CFML/s / CFM194 / 410184 / 390175 / 370EXTERNAL STATIC PRESSURE (H/M/L) Pa (in.wg.)N/ASOUND PRESSURE LEVEL (H/M/L)dBA 44 / 43 / 42 44 / 42 / 41UNIT DIMENSIONPACKINGDIMENSIONHEIGHTWIDTHDEPTHHEIGHTWIDTHDEPTHmm/inmm/inmm/inmm/inmm/inmm/in250 (295) / 9.8 (11.6)570 (640) / 22.4 (25.2)570 (640) / 22.4 (25.2)317 (127) / 12.5 (5).0630 (700) / 24.8 (27.6)630 (700) / 24.8 (27.6)UNIT WEIGHTkg/lb 22 + 2 / 49 + 4 23 + 2 / 51 + 4CONDENSATE DRAIN SIZEAIR FLOWSOUND PRESSURE LEVELmm/inL/s / CFMdBA19.1 / ¾1132.7 / 240062UNIT DIMENSIONPACKINGDIMENSIONUNIT WEIGHTHEIGHTWIDTHDEPTHHEIGHTWIDTHDEPTHmm/inmm/inmm/inmm/inmm/inmm/inkg/lb632 / 24.9960 / 37.8437 / 17.2824 / 32.41,194 / 47.0611 / 24.1105 / 231.5INDOOR UNITOUTDOOR UNITTYPEFLARE VALVEPIPE CONNECTIONREFRIGERANT CHARGESIZELIQUID mm/in3 x 6.35 / 3 x ¼GAS mm/in 9.52 / ⅜ 2 X 12.7 / 2 X ½kg/lb 0.80 / 1.76 2 x 0.83 x 2 x 1.831) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW :a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1.4m BELOW FACIA.95

General Data - Cooling Only (R22)MODELNOMINAL CAPACITYNOMINAL TOTAL INPUT POWERNOMINAL RUNNING CURRENTEERPOWER SOURCEREFRIGERANT TYPE / CONTROLINDOOR UNITOUTDOOR UNITBtu/hWWAW/WV/Ph/HzMMST101015A2 x MCK010C MCK015C31700 (9500 - 31700)9280 (2780 - 9270)3233 (1053 - 3233)14.91 (4.50 - 14.91)2.88220 ~ 240 / 1 / 50R22 / CAPILLARY TUBECONTROLAIR DISCHARGEOPERATION4 WAY AUTOMATIC LOUVER (UP & DOWN)WIRELESS OR WIRED MICROCOMPUTER REMOTE CONTROLAIR FLOWHIGHMEDIUMLOWL/s / CFML/s / CFML/s / CFM194 / 410184 / 390175 / 370EXTERNAL STATIC PRESSURE (H/M/L) Pa (in.wg.)N/ASOUND PRESSURE LEVEL (H/M/L)dBA 44 / 43 / 42 44 / 42 / 41UNIT DIMENSIONPACKINGDIMENSIONHEIGHTWIDTHDEPTHHEIGHTWIDTHDEPTHmm/inmm/inmm/inmm/inmm/inmm/in250 (295) / 9.8 (11.6)570 (640) / 22.4 (25.2)570 (640) / 22.4 (25.2)317 (127) / 12.5 (5).0630 (700) / 24.8 (27.6)630 (700) / 24.8 (27.6)UNIT WEIGHTkg/lb 22 + 2 / 49 + 4 23 + 2 / 51 + 4CONDENSATE DRAIN SIZEAIR FLOWSOUND PRESSURE LEVELmm/inL/s / CFMdBA19.1 / ¾1132.7 / 240061UNIT DIMENSIONPACKINGDIMENSIONHEIGHTWIDTHDEPTHHEIGHTWIDTHDEPTHmm/inmm/inmm/inmm/inmm/inmm/in632 / 24.9960 / 37.8437 / 17.2824 / 32.41,194 / 47.0611 / 24.1INDOOR UNITOUTDOOR UNITUNIT WEIGHTTYPEkg/lb63 / 138.9FLARE VALVEPIPE CONNECTIONREFRIGERANT CHARGESIZELIQUID mm/in3 x 6.35 / 3 x ¼GAS mm/in 2 x 9.52 / 2 x ⅜ 12.7 ½kg/lb 2 x 0.80 / 2 x 1.76 2 x 0.83 x 2 x 1.831) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW :a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1.4m BELOW FACIA.94

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!