Multi-Split Systems - McQuay
Multi-Split Systems - McQuay Multi-Split Systems - McQuay
General Data - Heatpump (R22)1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW :a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOORb) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT AND1m BELOW THE UNIT.50
General Data - Heatpump (R22)1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW :a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOORb) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT AND1m BELOW THE UNIT.51
- Page 1: CatalogMMS - 2008Multi-Split System
- Page 8: OUTDOORINDOORCooling : MWM 010/015G
- Page 14 and 15: MODEL :MMSH8K8A12
- Page 16 and 17: MODEL :MMSH66K66A14
- Page 18 and 19: MODEL :MMSD/M4MSD 1010 / 1015 / 151
- Page 20 and 21: ControllersG7 Remote Controller146T
- Page 22 and 23: SLM Operating InstructionsSLM1. “
- Page 24 and 25: Operating State and Fault TableWire
- Page 26 and 27: Installation In Zone Exposed To Str
- Page 28 and 29: 2) MMST / M4MST3) MMSH26
- Page 30 and 31: Diagram 1Additional Charge (For Fla
- Page 32 and 33: c) Ensure that the compressor is no
- Page 34 and 35: d) When charging R410A, ensure that
- Page 36 and 37: Engineering and Physical DatataMMSD
- Page 38 and 39: General Data - Cooling Only (R22)1)
- Page 40 and 41: General Data - Cooling Only (R22)1)
- Page 42 and 43: General Data - Cooling Only (R22)MO
- Page 44 and 45: General Data - Cooling Only (R22)MO
- Page 46 and 47: General Data - Cooling Only (R22)MO
- Page 48 and 49: General Data - Cooling Only (R22)MO
- Page 50 and 51: General Data - Cooling Only (R22)MO
- Page 54 and 55: General Data - Cooling Only (R407C)
- Page 56 and 57: General Data - Heatpump (R407C)1) A
- Page 58 and 59: Components Data - Cooling Only (R22
- Page 60 and 61: Components Data - Cooling Only (R22
- Page 62 and 63: Components Data - Cooling Only (R22
- Page 64 and 65: Components Data - Cooling Only (R22
- Page 66 and 67: Components Data - Cooling Only (R22
- Page 68 and 69: Components Data - Cooling Only (R22
- Page 70 and 71: Components Data - Cooling Only (R22
- Page 72 and 73: Components Data - Cooling Only (R22
- Page 74 and 75: Components Data - Heatpump (R22)1)
- Page 76 and 77: Components Data - Cooling Only (R40
- Page 78 and 79: Components Data - Heatpump (R407C)1
- Page 80 and 81: MMSTGeneral Data - Cooling Only (R2
- Page 82 and 83: General Data - Cooling Only (R22)1)
- Page 84 and 85: General Data - Cooling Only (R22)1)
- Page 86 and 87: General Data - Cooling Only (R22)1)
- Page 88 and 89: General Data - Cooling Only (R22)1)
- Page 90: General Data - Cooling Only (R22)MO
- Page 93 and 94: General Data - Cooling Only (R22)OU
- Page 95 and 96: General Data - Cooling Only (R22)MO
- Page 97 and 98: General Data - Cooling Only (R22)IN
- Page 99 and 100: General Data - Cooling Only (R22)IN
- Page 101 and 102: General Data - Cooling Only (R22)OU
General Data - Heatpump (R22)1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW :a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOORb) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT AND1m BELOW THE UNIT.50