General Data - Cooling Only (R22)MODELOUTDOOR UNITMMSD1520AINDOOR UNITMCC015CMCC020CNOMINAL CAPACITYBtu/h 12700 18000W 3720 5280NOMINAL TOTAL INPUT ONE UNIT RUNNING W 1577 2167POWERTWO UNITS RUNNING W3521NOMINAL RUNNING ONE UNIT RUNNING A 7.0 10.6CURRENTEERPOWER SOURCETWO UNITS RUNNING AW/WV/Ph/Hz16.92.56220 ~ 240 / 1 / 50REFRIGERANT TYPE / CONTROLR22 / CAPILLARY TUBECONTROLAIR DISCHARGEDUCTEDOPERATIONSLM WIRED HANDSETHIGHl/s / cfm 241 / 510 241 / 510AIR FLOWMEDIUMl/s / cfm 208 / 440 208 / 440LOWl/s / cfm 170 / 360 170 / 360EXTERNAL STATIC PRESSURE (H/M/L) Pa/in.wg. 49 / 39 / 20 (0.2 / 0.2 / 0.1) 49 / 39 / 20 (0.2 / 0.2 / 0.1)SOUND PRESSURE LEVEL (H/M/L)dBA 37 / 34 / 29 37 / 34 / 29HEIGHTmm/in 261 / 10.3 261 / 10.3UNIT DIMENSIONWIDTHmm/in 905 / 35.6 1065 / 41.9DEPTHmm/in 411 / 16.2 411 / 16.2HEIGHTmm/in 376 / 14.8 376 / 14.8PACKINGDIMENSIONWIDTHmm/in 1091 / 43.0 1251 / 49.3DEPTHmm/in 541 / 21.3 541 / 21.3UNIT WEIGHTkg/lb 21 / 46 22 / 49CONDENSATE DRAIN SIZEAIR FLOWSOUND PRESSURE LEVELmm/inl/s / cfmdBA19.1 / ¾1132.7 / 240056UNIT DIMENSIONPACKINGDIMENSIONUNIT WEIGHTHEIGHTWIDTHDEPTHHEIGHTWIDTHDEPTHmm/inmm/inmm/inmm/inmm/inmm/inkg/lb646 / 25.4840 / 33.1330 / 13.0710 / 28.0982 / 38.7461 / 18.163 / 138.89INDOOR UNITOUTDOOR UNITPIPE CONNECTIONREFRIGERANT CHARGESIZETYPEFLARE VALVELIQUID mm/in2 x 6.35 / 2 x ¼GAS mm/in 9.52 / ⅜ 12.7 / ½kg/lb1.675 / 3.691) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW :a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1.5m BELOW UNIT.(TESTED WITH 2M LENGTH DUCT AT AIR DISCHARGE OUTLET AND 1M DUCT LENGTH AT AIR RETURN INLET.)42

General Data - Cooling Only (R22)MODELOUTDOOR UNITMMSD2020AINDOOR UNIT2 x MCC020CNOMINAL CAPACITYBtu/h 2 x 18000W 2 x 5280NOMINAL TOTAL INPUT ONE UNIT RUNNING W 2173POWERTWO UNITS RUNNING W 4762NOMINAL RUNNING ONE UNIT RUNNING A 10.6CURRENTTWO UNITS RUNNING A 22.7EERW/W 2.22POWER SOURCEV/Ph/Hz 220 ~ 240 / 1 / 50REFRIGERANT TYPE / CONTROLR22 / CAPILLARY TUBECONTROLAIR DISCHARGEDUCTEDOPERATIONSLM WIRED HANDSETHIGHl/s / cfm 241 / 510AIR FLOWMEDIUMl/s / cfm 208 / 440LOWl/s / cfm 170 / 360EXTERNAL STATIC PRESSURE (H/M/L) Pa/in.wg. 49 / 39 / 20 (0.2 / 0.2 / 0.1)SOUND PRESSURE LEVEL (H/M/L)dBA 37 / 34 / 29HEIGHTmm/in 261 / 10.3UNIT DIMENSIONWIDTHmm/in 1065 / 41.9DEPTHmm/in 411 / 16.2HEIGHTmm/in 376 / 14.8PACKINGDIMENSIONWIDTHmm/in 1251 / 49.3DEPTHmm/in 541 / 21.3UNIT WEIGHTkg/lb 22 / 49CONDENSATE DRAIN SIZEmm/in19.1 / ¾AIR FLOWl/s / cfm 1132.7 / 2400SOUND PRESSURE LEVELdBA 61HEIGHTmm/in 632 / 24.9UNIT DIMENSIONWIDTHmm/in 690 / 37.8DEPTHmm/in 437 / 17.2HEIGHTmm/in 824 / 32.4PACKINGDIMENSIONWIDTHmm/in 1194 / 47.0DEPTHmm/in 611 / 24.1UNIT WEIGHTTYPEkg/lb 106 / 234FLARE VALVEPIPE CONNECTIONSIZELIQUID mm/in 2 X 2.4 / 2 X ¼GAS mm/in 2 X 15.9 / 2 X ⅝REFRIGERANT CHARGEkg/lb 2 X 1.83 / 2 X 4.03INDOOR UNITOUTDOOR UNIT1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW :a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1.5m BELOW UNIT.(TESTED WITH 2M LENGTH DUCT AT AIR DISCHARGE OUTLET AND 1M DUCT LENGTH AT AIR RETURN INLET.)43

General Data - Cooling Only (R22)MODELOUTDOOR UNITMMSD2020AINDOOR UNIT2 x MCC020CNOMINAL CAPACITYBtu/h 2 x 18000W 2 x 5280NOMINAL TOTAL INPUT ONE UNIT RUNNING W 2173POWERTWO UNITS RUNNING W 4762NOMINAL RUNNING ONE UNIT RUNNING A 10.6CURRENTTWO UNITS RUNNING A 22.7EERW/W 2.22POWER SOURCEV/Ph/Hz 220 ~ 240 / 1 / 50REFRIGERANT TYPE / CONTROLR22 / CAPILLARY TUBECONTROLAIR DISCHARGEDUCTEDOPERATIONSLM WIRED HANDSETHIGHl/s / cfm 241 / 510AIR FLOWMEDIUMl/s / cfm 208 / 440LOWl/s / cfm 170 / 360EXTERNAL STATIC PRESSURE (H/M/L) Pa/in.wg. 49 / 39 / 20 (0.2 / 0.2 / 0.1)SOUND PRESSURE LEVEL (H/M/L)dBA 37 / 34 / 29HEIGHTmm/in 261 / 10.3UNIT DIMENSIONWIDTHmm/in 1065 / 41.9DEPTHmm/in 411 / 16.2HEIGHTmm/in 376 / 14.8PACKINGDIMENSIONWIDTHmm/in 1251 / 49.3DEPTHmm/in 541 / 21.3UNIT WEIGHTkg/lb 22 / 49CONDENSATE DRAIN SIZEmm/in19.1 / ¾AIR FLOWl/s / cfm 1132.7 / 2400SOUND PRESSURE LEVELdBA 61HEIGHTmm/in 632 / 24.9UNIT DIMENSIONWIDTHmm/in 690 / 37.8DEPTHmm/in 437 / 17.2HEIGHTmm/in 824 / 32.4PACKINGDIMENSIONWIDTHmm/in 1194 / 47.0DEPTHmm/in 611 / 24.1UNIT WEIGHTTYPEkg/lb 106 / 234FLARE VALVEPIPE CONNECTIONSIZELIQUID mm/in 2 X 2.4 / 2 X ¼GAS mm/in 2 X 15.9 / 2 X ⅝REFRIGERANT CHARGEkg/lb 2 X 1.83 / 2 X 4.03INDOOR UNITOUTDOOR UNIT1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW :a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1.5m BELOW UNIT.(TESTED WITH 2M LENGTH DUCT AT AIR DISCHARGE OUTLET AND 1M DUCT LENGTH AT AIR RETURN INLET.)43

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!