General Data - Cooling Only (R22)MODELOUTDOOR UNITMMSD1015AINDOOR UNITMCC010CMCC015CNOMINAL CAPACITYBtu/h 9500 12700W 2780 3270NOMINAL TOTAL INPUT ONE UNIT RUNNING W 1059 1525POWERTWO UNITS RUNNING W2417NOMINAL RUNNING ONE UNIT RUNNING A 4.7 6.7CURRENTEERPOWER SOURCETWO UNITS RUNNING AW/WV/Ph/Hz10.72.69220 ~ 240 / 1 / 50REFRIGERANT TYPE / CONTROLR22 / CAPILLARY TUBECONTROLAIR DISCHARGEDUCTEDOPERATIONSLM WIRED HANDSETHIGHl/s / cfm 142 / 300 241 / 510AIR FLOWMEDIUMl/s / cfm 123 / 260 208 / 440LOWl/s / cfm 104 / 220 170 / 360EXTERNAL STATIC PRESSURE (H/M/L) Pa/in.wg. 49 / 39 / 29 (0.2 / 0.2 / 0.1) 49 / 39 / 20 (0.2 / 0.2 / 0.1)SOUND PRESSURE LEVEL (H/M/L)dBA 33 / 30 / 26 37 / 34 / 29HEIGHTmm/in 261 / 10.3 261 / 10.3UNIT DIMENSIONWIDTHmm/in 765 / 30.1 905 / 35.6DEPTHmm/in 411 / 16.2 411 / 16.2HEIGHTmm/in 376 / 14.8 376 / 14.8PACKINGDIMENSIONWIDTHmm/in 951 / 37.4 1091 / 43.0DEPTHmm/in 535 / 21.3 541 / 21.3UNIT WEIGHTkg/lb 17 / 38 21 / 46CONDENSATE DRAIN SIZEAIR FLOWSOUND PRESSURE LEVELmm/inl/s / cfmdBA19.1 / ¾660.8 / 40056UNIT DIMENSIONPACKINGDIMENSIONUNIT WEIGHTHEIGHTWIDTHDEPTHHEIGHTWIDTHDEPTHmm/inmm/inmm/inmm/inmm/inmm/inkg/lb646 / 25.4840 / 33.1330 / 13.0710 / 28.0982 / 38.7461 / 18.163 / 138.89INDOOR UNITOUTDOOR UNITPIPE CONNECTIONREFRIGERANT CHARGESIZETYPEFLARE VALVELIQUID mm/in2 x 6.35 / 2 x ¼GAS mm/in 9.52 / ⅜ 12.7 / ½kg/lb1.675 / 3.691) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW :a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1.5m BELOW UNIT.(TESTED WITH 2M LENGTH DUCT AT AIR DISCHARGE OUTLET AND 1M DUCT LENGTH AT AIR RETURN INLET.)40
General Data - Cooling Only (R22)MODELOUTDOOR UNITMMSD1020AINDOOR UNITMCC010CMCC020CNOMINAL CAPACITYBtu/h 9500 18000W 2780 5280NOMINAL TOTAL INPUT ONE UNIT RUNNING W 1111 2167POWERTWO UNITS RUNNING W3191NOMINAL RUNNING ONE UNIT RUNNING A 4.9 10.6CURRENTEERPOWER SOURCETWO UNITS RUNNING AW/WV/Ph/Hz15.02.53220 ~ 240 / 1 / 50REFRIGERANT TYPE / CONTROLR22 / CAPILLARY TUBECONTROLAIR DISCHARGEDUCTEDOPERATIONSLM WIRED HANDSETHIGHl/s / cfm 142 / 300 241 / 510AIR FLOWMEDIUMl/s / cfm 123 / 260 208 / 440LOWl/s / cfm 104 / 220 170 / 360EXTERNAL STATIC PRESSURE (H/M/L) Pa/in.wg. 49 / 39 / 29 (0.2 / 0.2 / 0.1) 49 / 39 / 20 (0.2 / 0.2 / 0.1)SOUND PRESSURE LEVEL (H/M/L)dBA 33 / 30 / 26 37 / 34 / 29HEIGHTmm/in 261 / 10.3 261 / 10.3UNIT DIMENSIONWIDTHmm/in 765 / 30.1 1065 / 41.9DEPTHmm/in 411 / 16.2 411 / 16.2HEIGHTmm/in 376 / 14.8 376 / 14.8PACKINGDIMENSIONWIDTHmm/in 951 / 37.4 1251 / 49.3DEPTHmm/in 535 / 21.3 541 / 21.3UNIT WEIGHTkg/lb 17 / 38 22 / 49CONDENSATE DRAIN SIZEAIR FLOWSOUND PRESSURE LEVELmm/inl/s / cfmdBA19.1 / ¾1132.7 / 240056UNIT DIMENSIONPACKINGDIMENSIONUNIT WEIGHTHEIGHTWIDTHDEPTHHEIGHTWIDTHDEPTHmm/inmm/inmm/inmm/inmm/inmm/inkg/lb646 / 25.4840 / 33.1330 / 13.0710 / 28.0982 / 38.7461 / 18.163 / 138.89INDOOR UNITOUTDOOR UNITPIPE CONNECTIONREFRIGERANT CHARGESIZETYPEFLARE VALVELIQUID mm/in2 x 6.35 / 2 x ¼GAS mm/in 9.52 / ⅜ 12.7 / ½kg/lb1.675 / 3.691) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW :a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1.5m BELOW UNIT.(TESTED WITH 2M LENGTH DUCT AT AIR DISCHARGE OUTLET AND 1M DUCT LENGTH AT AIR RETURN INLET.)41
- Page 1: CatalogMMS - 2008Multi-Split System
- Page 8: OUTDOORINDOORCooling : MWM 010/015G
- Page 14 and 15: MODEL :MMSH8K8A12
- Page 16 and 17: MODEL :MMSH66K66A14
- Page 18 and 19: MODEL :MMSD/M4MSD 1010 / 1015 / 151
- Page 20 and 21: ControllersG7 Remote Controller146T
- Page 22 and 23: SLM Operating InstructionsSLM1. “
- Page 24 and 25: Operating State and Fault TableWire
- Page 26 and 27: Installation In Zone Exposed To Str
- Page 28 and 29: 2) MMST / M4MST3) MMSH26
- Page 30 and 31: Diagram 1Additional Charge (For Fla
- Page 32 and 33: c) Ensure that the compressor is no
- Page 34 and 35: d) When charging R410A, ensure that
- Page 36 and 37: Engineering and Physical DatataMMSD
- Page 38 and 39: General Data - Cooling Only (R22)1)
- Page 40 and 41: General Data - Cooling Only (R22)1)
- Page 44 and 45: General Data - Cooling Only (R22)MO
- Page 46 and 47: General Data - Cooling Only (R22)MO
- Page 48 and 49: General Data - Cooling Only (R22)MO
- Page 50 and 51: General Data - Cooling Only (R22)MO
- Page 52 and 53: General Data - Heatpump (R22)1) ALL
- Page 54 and 55: General Data - Cooling Only (R407C)
- Page 56 and 57: General Data - Heatpump (R407C)1) A
- Page 58 and 59: Components Data - Cooling Only (R22
- Page 60 and 61: Components Data - Cooling Only (R22
- Page 62 and 63: Components Data - Cooling Only (R22
- Page 64 and 65: Components Data - Cooling Only (R22
- Page 66 and 67: Components Data - Cooling Only (R22
- Page 68 and 69: Components Data - Cooling Only (R22
- Page 70 and 71: Components Data - Cooling Only (R22
- Page 72 and 73: Components Data - Cooling Only (R22
- Page 74 and 75: Components Data - Heatpump (R22)1)
- Page 76 and 77: Components Data - Cooling Only (R40
- Page 78 and 79: Components Data - Heatpump (R407C)1
- Page 80 and 81: MMSTGeneral Data - Cooling Only (R2
- Page 82 and 83: General Data - Cooling Only (R22)1)
- Page 84 and 85: General Data - Cooling Only (R22)1)
- Page 86 and 87: General Data - Cooling Only (R22)1)
- Page 88 and 89: General Data - Cooling Only (R22)1)
- Page 90: General Data - Cooling Only (R22)MO
General Data - Cooling Only (R22)MODELOUTDOOR UNITMMSD1015AINDOOR UNITMCC010CMCC015CNOMINAL CAPACITYBtu/h 9500 12700W 2780 3270NOMINAL TOTAL INPUT ONE UNIT RUNNING W 1059 1525POWERTWO UNITS RUNNING W2417NOMINAL RUNNING ONE UNIT RUNNING A 4.7 6.7CURRENTEERPOWER SOURCETWO UNITS RUNNING AW/WV/Ph/Hz10.72.69220 ~ 240 / 1 / 50REFRIGERANT TYPE / CONTROLR22 / CAPILLARY TUBECONTROLAIR DISCHARGEDUCTEDOPERATIONSLM WIRED HANDSETHIGHl/s / cfm 142 / 300 241 / 510AIR FLOWMEDIUMl/s / cfm 123 / 260 208 / 440LOWl/s / cfm 104 / 220 170 / 360EXTERNAL STATIC PRESSURE (H/M/L) Pa/in.wg. 49 / 39 / 29 (0.2 / 0.2 / 0.1) 49 / 39 / 20 (0.2 / 0.2 / 0.1)SOUND PRESSURE LEVEL (H/M/L)dBA 33 / 30 / 26 37 / 34 / 29HEIGHTmm/in 261 / 10.3 261 / 10.3UNIT DIMENSIONWIDTHmm/in 765 / 30.1 905 / 35.6DEPTHmm/in 411 / 16.2 411 / 16.2HEIGHTmm/in 376 / 14.8 376 / 14.8PACKINGDIMENSIONWIDTHmm/in 951 / 37.4 1091 / 43.0DEPTHmm/in 535 / 21.3 541 / 21.3UNIT WEIGHTkg/lb 17 / 38 21 / 46CONDENSATE DRAIN SIZEAIR FLOWSOUND PRESSURE LEVELmm/inl/s / cfmdBA19.1 / ¾660.8 / 40056UNIT DIMENSIONPACKINGDIMENSIONUNIT WEIGHTHEIGHTWIDTHDEPTHHEIGHTWIDTHDEPTHmm/inmm/inmm/inmm/inmm/inmm/inkg/lb646 / 25.4840 / 33.1330 / 13.0710 / 28.0982 / 38.7461 / 18.163 / 138.89INDOOR UNITOUTDOOR UNITPIPE CONNECTIONREFRIGERANT CHARGESIZETYPEFLARE VALVELIQUID mm/in2 x 6.35 / 2 x ¼GAS mm/in 9.52 / ⅜ 12.7 / ½kg/lb1.675 / 3.691) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW :a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1.5m BELOW UNIT.(TESTED WITH 2M LENGTH DUCT AT AIR DISCHARGE OUTLET AND 1M DUCT LENGTH AT AIR RETURN INLET.)40