Multi-Split Systems - McQuay

Multi-Split Systems - McQuay Multi-Split Systems - McQuay

09.07.2015 Views

Operating State and Fault TableWireless Remote ControlCooling : LED Indicator Light DisplayHeatpump : LED Indicator DisplayPOWER TIMER SLEEP POWER TIMER HEATPOWER TIMER SLEEP HEAT Normal Operation / Fault IndicationCool ModeTimer OnSleep Mode OnHeat ModeAuto Mode - CoolAuto Mode - Heat1 Time2 Times3 Times1 Time2 Times3 TimesCompressor - OverloadPump FaultGas LeakRoom Sensor Open Or ShortIndoor Coil Sensor Open Or ShortOutdoor Coil Sensor Open Or Short - ON /• - ON or OFF - BlinkingWired Remote Control (Universal)Cooling / Heatpump ModelError Code at 7 Segment DisplayBlink E1Blink E2Blink E3Blink E4Blink E5Blink E6Blink Heat LEDOperation / Faulty IndicationRoom sensor contact open or shortIndoor coil sensor contact openOutdoor coil sensor contact openCompressor overload /Indoor coil sensor short /Outdoor coil sensor shortGas leakWater pump faultyOutdoor defrost (for Heatpump only)22

Precaution And InstallationLocation For Installation Of The Condensing UnitsAs condensing temperature rises, evaporating temperature rises and cooling capacity drops. In order to achievemaximum cooling capacity, the location selected for outdoor unit should fulfill the following requirements :Install the condensing (outdoor) unit in a way such that hot air distributed by the outdoor condensing unitcannot be drawn in again (as in the case of short circuit of hot discharge air). Allow sufficient space formaintenance around the unit.Ensure that there is no obstruction of air flow into or out of the unit. Remove obstacles which block air intakeor discharge.The location must be well ventilated, so that the unit can draw in and distribute plenty of air thus loweringthe condensing temperature.A place capable of bearing the weight of the outdoor unit and isolating noise and vibration.A place protected from direct sunlight. Otherwise use an awning for protection, if necessary.The location must not be susceptible to dust or oil mist.CAUTION : If the condensing unit is operated in an atmosphere containing oils (including machineoils), salt (coastal area), sulphide gas (near hot spring, oil refinery plant), such substancesmay lead to failure of the unit.23

Operating State and Fault TableWireless Remote ControlCooling : LED Indicator Light DisplayHeatpump : LED Indicator DisplayPOWER TIMER SLEEP POWER TIMER HEATPOWER TIMER SLEEP HEAT Normal Operation / Fault IndicationCool ModeTimer OnSleep Mode OnHeat ModeAuto Mode - CoolAuto Mode - Heat1 Time2 Times3 Times1 Time2 Times3 TimesCompressor - OverloadPump FaultGas LeakRoom Sensor Open Or ShortIndoor Coil Sensor Open Or ShortOutdoor Coil Sensor Open Or Short - ON /• - ON or OFF - BlinkingWired Remote Control (Universal)Cooling / Heatpump ModelError Code at 7 Segment DisplayBlink E1Blink E2Blink E3Blink E4Blink E5Blink E6Blink Heat LEDOperation / Faulty IndicationRoom sensor contact open or shortIndoor coil sensor contact openOutdoor coil sensor contact openCompressor overload /Indoor coil sensor short /Outdoor coil sensor shortGas leakWater pump faultyOutdoor defrost (for Heatpump only)22

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!