Electrical Data - Cooling Only (R22)MODELINDOOR UNITMMSD1010AMMSD1515AOUTDOOR UNIT2 x MCK010C 2 x MCK015CINSULATION GRADECLASS EPOWER SOURCEV/Ph/Hz220 ~ 240 / 1 / 50INDOOR MOTORRATED INPUT POWER W 54 60RATED RUNNING CURRENT A 0.23 0.27MOTOR OUTPUT W 16 18POLES 6INSULATION GRADECLASS EPOWER SOURCEV/Ph/Hz220 ~ 240 / 1 / 50OUTDOOR MOTOR RATED INPUT POWERW170RATED RUNNING CURRENTA0.72MOTOR OUTPUTW70INSULATION GRADEN/APOWER SOURCEV/Ph/Hz220 ~ 240 / 1 / 50COMPRESSORCAPACITORmF30RATED INPUT POWER W 821 1259RATED RUNNING CURRENT A 3.64 5.58LOCKED ROTOR AMP. A 20 25MODELINDOOR MOTOROUTDOOR MOTORCOMPRESSORINDOOR UNITMMSD1015AOUTDOOR UNIT MCK010C MCK015CINSULATION GRADECLASS EPOWER SOURCEV/Ph/Hz220 ~ 240 / 1 / 50RATED INPUT POWER W 54 60RATED RUNNING CURRENT A 0.23 0.27MOTOR OUTPUT W 16 18POLES 6INSULATION GRADEPOWER SOURCEV/Ph/HzRATED INPUT POWERWCLASS E220 ~ 240 / 1 / 50170RATED RUNNING CURRENTA0.72MOTOR OUTPUTW70INSULATION GRADEN/APOWER SOURCEV/Ph/Hz220 ~ 240 / 1 / 50CAPACITORmF30RATED INPUT POWER W 821 1259RATED RUNNING CURRENT A 3.64 5.58LOCKED ROTOR AMP. A 20 251) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.170
Electrical Data - Cooling Only (R22)MODELINDOOR UNITMMSD1020AOUTDOOR UNITMCK010CMCK020CINSULATION GRADECLASS EPOWER SOURCEV/Ph/Hz220 ~ 240 / 1 / 50INDOOR MOTORRATED INPUT POWER W 54 72RATED RUNNING CURRENT A 0.23 0.32MOTOR OUTPUT W 16 22POLES 6INSULATION GRADECLASS EPOWER SOURCEV/Ph/Hz220 ~ 240 / 1 / 50OUTDOOR MOTOR RATED INPUT POWERW222RATED RUNNING CURRENTA0.98MOTOR OUTPUTW50INSULATION GRADEN/APOWER SOURCEV/Ph/Hz220 ~ 240 / 1 / 50COMPRESSORCAPACITOR mF 30 45RATED INPUT POWER W 821 1804RATED RUNNING CURRENT A 3.64 9.00LOCKED ROTOR AMP. A 20 56MODELINDOOR MOTOROUTDOOR MOTORCOMPRESSORINDOOR UNITMMSD1520AOUTDOOR UNIT MCK015C MCK020CINSULATION GRADECLASS EPOWER SOURCEV/Ph/Hz220 ~ 240 / 1 / 50RATED INPUT POWER W 60 72RATED RUNNING CURRENT A 0.27 0.32MOTOR OUTPUT W 18 22POLES 6INSULATION GRADEPOWER SOURCEV/Ph/HzRATED INPUT POWERWCLASS E220 ~ 240 / 1 / 50222RATED RUNNING CURRENTA0.98MOTOR OUTPUTW50INSULATION GRADEN/APOWER SOURCEV/Ph/Hz220 ~ 240 / 1 / 50CAPACITOR mF 30 45RATED INPUT POWER W 1259 1804RATED RUNNING CURRENT A 5.58 9.00LOCKED ROTOR AMP. A 25 561) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.171
- Page 121 and 122: Components Data - Cooling Only (R22
- Page 123 and 124: Components Data - Cooling Only (R22
- Page 125 and 126: Components Data - Cooling Only (R22
- Page 127 and 128: Components Data - Cooling Only (R22
- Page 129 and 130: Components Data - Cooling Only (R22
- Page 131 and 132: Components Data - Cooling Only (R22
- Page 133 and 134: Components Data - Cooling Only (R22
- Page 135 and 136: Components Data - Heatpump (R22)1)
- Page 137 and 138: Components Data - Heatpump (R22)1)
- Page 139 and 140: Components Data - Cooling Only (R40
- Page 141 and 142: Components Data - Heatpump (R407C)1
- Page 143 and 144: Components Data - Heatpump (R407C)1
- Page 145 and 146: Capacity Data - Heatpump (R22)Cooli
- Page 147 and 148: Capacity Data - Heatpump (R407C)OUT
- Page 149 and 150: Capacity Data - Cooling Only (R22)O
- Page 151 and 152: General Data - Cooling Only (R22)1)
- Page 153 and 154: Components Data - Cooling Only (R22
- Page 155 and 156: Components Data - Cooling Only (R22
- Page 157 and 158: Capacity Data - Cooling Only (R22)O
- Page 159 and 160: MODEL :MMSD 2020ANote : Dimension i
- Page 161 and 162: MODEL :MMSH 8K66 ANote : Dimension
- Page 163 and 164: INDOOR UNITMODEL : MWM 010/015 G/GR
- Page 165 and 166: INDOOR UNITMODEL : MCK 025 AMCK 010
- Page 167 and 168: Electrical Data - Cooling Only (R22
- Page 169 and 170: Electrical Data - Cooling Only (R22
- Page 171: Electrical Data - Cooling Only (R22
- Page 175 and 176: Electrical Data - Heatpump (R22)1)
- Page 177 and 178: Electrical Data - Cooling Only (R40
- Page 179 and 180: MMSTElectrical Data - Cooling Only
- Page 181 and 182: Electrical Data - Cooling Only (R22
- Page 183 and 184: Electrical Data - Cooling Only (R22
- Page 185 and 186: Electrical Data - Cooling Only (R22
- Page 187 and 188: Electrical Data - Cooling Only (R22
- Page 189 and 190: Electrical Data - Cooling Only (R22
- Page 191 and 192: Electrical Data - Cooling Only (R22
- Page 193 and 194: Electrical Data - Heatpump (R22)1)
- Page 195 and 196: Electrical Data - Cooling Only (R40
- Page 197 and 198: Electrical Data - Heatpump (R407C)1
- Page 199 and 200: Electrical Data - Cooling Only (R22
- Page 201 and 202: OUTDOOR UNIT - COOLING ONLYMODEL :
- Page 203 and 204: OUTDOOR UNIT - COOLING ONLYMODEL :
- Page 205 and 206: OUTDOOR UNIT - HEATPUMPMODEL : MMSD
- Page 207 and 208: INDOOR UNIT - COOLING ONLYMODEL : M
- Page 209 and 210: INDOOR UNIT - HEATPUMPMODEL : MWM 0
- Page 211 and 212: INDOOR UNITMODEL : MCK 010CMODEL :M
- Page 213 and 214: INDOOR UNITMODEL : MCC 010CMODEL :M
- Page 215 and 216: Servicing and MaintenanceThe design
- Page 217 and 218: MODEL : MMST 101025 / 101520 / 1015
- Page 219 and 220: Generally, there are two kinds of c
- Page 221 and 222: MODEL : MMSD 1020A / 1520A219
Electrical Data - Cooling Only (R22)MODELINDOOR UNITMMSD1010AMMSD1515AOUTDOOR UNIT2 x MCK010C 2 x MCK015CINSULATION GRADECLASS EPOWER SOURCEV/Ph/Hz220 ~ 240 / 1 / 50INDOOR MOTORRATED INPUT POWER W 54 60RATED RUNNING CURRENT A 0.23 0.27MOTOR OUTPUT W 16 18POLES 6INSULATION GRADECLASS EPOWER SOURCEV/Ph/Hz220 ~ 240 / 1 / 50OUTDOOR MOTOR RATED INPUT POWERW170RATED RUNNING CURRENTA0.72MOTOR OUTPUTW70INSULATION GRADEN/APOWER SOURCEV/Ph/Hz220 ~ 240 / 1 / 50COMPRESSORCAPACITORmF30RATED INPUT POWER W 821 1259RATED RUNNING CURRENT A 3.64 5.58LOCKED ROTOR AMP. A 20 25MODELINDOOR MOTOROUTDOOR MOTORCOMPRESSORINDOOR UNITMMSD1015AOUTDOOR UNIT MCK010C MCK015CINSULATION GRADECLASS EPOWER SOURCEV/Ph/Hz220 ~ 240 / 1 / 50RATED INPUT POWER W 54 60RATED RUNNING CURRENT A 0.23 0.27MOTOR OUTPUT W 16 18POLES 6INSULATION GRADEPOWER SOURCEV/Ph/HzRATED INPUT POWERWCLASS E220 ~ 240 / 1 / 50170RATED RUNNING CURRENTA0.72MOTOR OUTPUTW70INSULATION GRADEN/APOWER SOURCEV/Ph/Hz220 ~ 240 / 1 / 50CAPACITORmF30RATED INPUT POWER W 821 1259RATED RUNNING CURRENT A 3.64 5.58LOCKED ROTOR AMP. A 20 251) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.170