08.07.2015 Views

IQL13+ Data Sheet - Trend

IQL13+ Data Sheet - Trend

IQL13+ Data Sheet - Trend

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>IQL13+</strong><strong>Data</strong> <strong>Sheet</strong>HARDWARE (continued)InputsIN1 Resistance Input(normally thermistor)IN2 Resistance Input(normally potentiometer)IN3 Resistance InputIN4 Digital InputIN5 Digital Input2122IN1COMIN2COMIN3IN4CIN5Inputs 1, 2, 3Variable resistance (analogue) inputs, 0 to 29 k The use of theinputs is defined by the strategy; the following are examples.Thermistor temperature sensor input (normallyinput 1). Thermistor inputs are scaled for a standard IQsystem thermistor (10 k at 25 °C, 77 °F). Scaling range2.5 °C to 60 °C(36.5 °F to 116 °F). Conversion accuracy±0.25 °C(±0.45 °F) over range (10 to 30 °C, 50 °F to86 °F).Potentiometer input (normally input 2). Scaled forstandard IQ system potentiometer (1 k to 11 k). Apotentiometer input is automatically self calibrating togive 0% to 100% of adjustment over full range ofpotentiometer. If required calibration may be set by turningpotentiometer to both ends of range, and waiting 6 secsat each endpoint.Fan Speed Control input (normally input 3). Inputresistance is set to one of five values by an externalswitch and decoded to give required fan speed selection(Off, Low manual, Medium manual, High manual, andAuto).232425262728terminal numbersIQLDisplayThe RD-IQL/K (Room Display) is a wall mounting temperaturesensor and 3 digit display with control and indication of setpoint.The RD-IQL/KOS also provides an occupation override switchand indication. The RD-IQL/KOSF also provides fan speed controland indication. The RD is connected to IN4. Some IQL configurationparameters must be changed for an IQL to operate with theRD-IQL (see strategy data sheet).Connecting an RD renders some of the normal featuresinoperative:RD-IQL/K: The RD’s potentiometer must be used, not IN2(if a potentiometer is required). A separate sensorconnected to IN1 may be used instead of the RD’s; thisis achieved by maintaining the normal sensor type forIN1. There will be no PIR or pushbutton input. A fan speedswitch connected to IN3 may be used.RD-IQL/KOS: The same as for RD-IQL/K but the /KOSgives use of its pushbutton.RD-IQL/KOSF: The same as for RD-IQL/KOS but the/KOSF gives use of its fan speed switch. A separate fanspeed switch connected to IN3 may be used instead ofthe RD’s; this is achieved by maintaining the normalsensor type for IN3.The SDU-LON (Smart Display Unit) is a wall mountingelectroluminescent display that can be connected to the LONWORKSbus and attached to its IQL. It enables the user to view and adjustselected parameters within the controller. The SDU-LON has areal time clock that can set the controller’s time, it also providesit with a time zone and calendar features (see SDU data sheetTA200559).SensorsThe TB/TS provides a wall mounting thermistor space sensorthat can be connected to the <strong>IQL13+</strong> input 1 (see TB/TS datasheet TA200603). The TB/TS/K also provides setpoint adjustmentto connect to input 2. The TB/TS/KE has the TB/TS/K featuresplus an occupation override pushbutton to connect to input 4.The TB/TS/KEF has the TB/TS/KE features plus a fan speedcontrol switch to connect to input 3.Inputs 4, 5Volt free contact (digital) inputs. 5 Vdc supply via 10 k. Wettingcurrent 0.5 mA. Input 4 provides a TBus connection for use bythe RD-IQL (room display).4 <strong>IQL13+</strong> LonMark Terminal Unit Controller <strong>Data</strong> <strong>Sheet</strong> TA200205 Issue 6, 4/03/2009

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!