Datacomtools.comTM
Datacomtools.comTM
Datacomtools.comTM
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
OTDR’s<br />
OptiFiber® Certifying OTDR<br />
- Boost productivity with an easy-to-use interface & lightweight design.<br />
- Diagnose fiber cabling issues with integrated ChannelMap, Auto<br />
OTDR and fiber endface inspection.<br />
- Certify fiber using integrated Auto OTDR analysis, automated loss and<br />
length measurements and fiber end-face inspection.<br />
- Enhance visibility into premise, campus & metro networks.<br />
- Document fiber with LinkWare data management & report software.<br />
Features OF-500-M OF-500-S OF-500-MS OF-500-M10 OF-500-MS35 OF-500-MS45<br />
Mainframe • • • • • •<br />
MM Module<br />
•<br />
SM Module<br />
•<br />
MM/SM Modules<br />
•<br />
MM OTDR/OPM/LL Module<br />
•<br />
MM/SM OTDR /OPM/LL Module • •<br />
DTX-MFM2/SU & DTX-SFM2/SU<br />
modules<br />
SmartRemote unit components<br />
•<br />
62.5µm & 50µm launch fibers • • •<br />
SM launch fibers • •<br />
Accessories for testing SC & LC • • •<br />
32MB MMC • • •<br />
Battery • • • • • •<br />
USB cable • • • • • Mini-B<br />
AC Adapter • • • • • (2)<br />
LinkWare CD’s and manuals • • • • • •<br />
Calibration certificate • • •<br />
MMC reader • • •<br />
200x/400x inspection camera • • •<br />
Carrying case w/strap • • • soft hard hard<br />
Price $9265.00 $10295.00 $14415.00 $30595.00 $31719.00 $40300.00<br />
Fiber Accessories<br />
NF395 APC/SC Video Probe Adapter Tip $183.00<br />
NF360 MT-RJ Video Probe Adapter Tip $185.00<br />
NF362 LC video Probe Adapter Tip $398.00<br />
NF364 MU Video Probe Adapter Tip $472.00<br />
NF366 E2000 Video Probe Adapter Tip $584.00<br />
NF300R Replacement Tip Set for Video Probe Adapter Tips $320.00<br />
NF232 Patch cable, simplex, SC-SC, 62.5/125, 0.3 meter $101.00<br />
NF234 Patch cable, simplex, SC-SC, 50/125, 0.3 meter $101.00<br />
NF236 Patch cable, simplex, SC-SC, SM, 0.3 meter $101.00<br />
NFK1-LAUNCH SC-SC 62.5/125µm launch cable, 100m $613.00<br />
NFK2-LAUNCH SC-SC 50/125µm Launch cable, 100m $613.00<br />
NFK3-LAUNCH SC-SC SM Launch cable, 130m $613.00<br />
OFBP-LI OptiFiber Li-Ion Battery $613.00<br />
OFCC-HCASE OptiFiber Hard Case $613.00<br />
NF400 Fiber Accessories Carrying Case $52.00<br />
NF-MANDREL-50 MM mandrel for 50/125µm w/3mm jacket red $10.00<br />
NF-MANDREL-625 MM mandrel for 62.5/125µm w/3mm jacket gray $10.00<br />
NFK1-MANDREL-KIT MM mandrel kit containing two red and two gray $27.00<br />
NFA-SC 2 SC adapters for DTX-xFM2 power meter port $201.00<br />
NFA-LC 2 LC adapters for DTX-xFM2 power meter port $201.00<br />
NFA-ST 2 ST adapters for DTX-xFM2 power meter port $201.00<br />
NFA-FC FC test adapters, 2 $201.00<br />
NFK1-DPLX-SC Duplex MM 62.5µm TRC for SC adapter, 2 $201.00<br />
NFK1-DPLX-LC Duplex MM 62.5µm TRC for LC adapter, 2 $195.00<br />
NFK1-DPLX-ST Duplex MM 62.5µm TRC for ST adapter, 2 $201.00<br />
NFK1-DPLX-FC Duplex MM 62.5µm TRC for FC adapter, 2 $201.00<br />
NFK2-DPLX-SC Duplex MM 50µm TRC for SC adapter, 2 $201.00<br />
NFK2-DPLX-LC Duplex MM 50µm TRC for LC adapter, 2 $201.00<br />
NFK2-DPLX-ST Duplex MM 50µm TRC for ST adapter, 2 $201.00<br />
NFK2-DPLX-FC Duplex MM 50µm TRC for FC adapter, 2 $201.00<br />
NFK3-DPLX-SC Duplex SM TRC for SC adapter, 2 $201.00<br />
NFK3-DPLX-LC Duplex SM TRC for LC adapter, 2 $201.00<br />
NFK3-DPLX-ST Duplex SM TRC for ST adapter, 2 $201.00<br />
NFK3-DPLX-FC Duplex SM TRC for FC adapter, 2 $201.00<br />
OTDR’s<br />
M700 Singlemode Compact OTDR<br />
- LSA Measurements in Expert mode<br />
- Pass/Fail Event and Link Thresholds settings<br />
- OTDR results saved as industry standard (GR-196) .SOR files<br />
- Stores results & displays up to three wavelengths simultaneously<br />
- Large, high bright, sunlight readable, touchscreen<br />
Compact, full featured, single-mode OTDR includes an integrated Visual Fault Locator (VFL), an Optical<br />
Power Meter (OPM) displaying up to three wavelengths simultaneously, and a large transflective touch<br />
screen display suitable for both indoor and outdoor operation.<br />
The M700 OTDR supports Real-Time, Full-Auto, and Expert modes, precision event analysis, dualwavelength<br />
testing, rich file naming, and an intuitive job set-up functionality. In addition to OTDR event<br />
analysis, pass/fail acceptance values, and marginal warning, specific values can be set to alert the test<br />
operator of failing or marginal events. Using one of the Least Squares Approximation (LSA) loss methods,<br />
events may be added or deleted manually.<br />
M700-20U-01 M700 OTDR, SM 1310/1550nm, Soft case $7500.00<br />
M700-21U-01 M700 OTDR, SM, 1310/1550/1625nm, Soft case $9879.00<br />
Contains:<br />
- M700 SM OTDR<br />
- OTDR trace analysis/OPM loss<br />
- Reporting software<br />
- AC adapter & USB drive<br />
- 1.25/2.5mm VFL/OPM<br />
- Universal adapters<br />
- SC/FC/LC OTDR adapter<br />
- Soft case<br />
General M700 Specifications<br />
Emitter Type<br />
Laser<br />
Safety Class Class 1 FDA 21 CFR 1040.0 & 1040.11<br />
Center Wavelengths 1310/1550nm<br />
Dynamic Range (SNR=1) 38/36dB (1310/1550nm)<br />
Event Dead Zone 0.9m<br />
Attenuation Dead Zone 5.5m<br />
Pulse Widths 5, 10, 30, 100, 300ns, 1, 3, 10, 20µs<br />
Distance Sampling Points Max. 64,000 points<br />
Data Point Spacing 0.125m, 0.25m, 0.5m, range/# of data points<br />
Range Settings<br />
250m to 256km<br />
Group Index of Refraction 1.4000 to 1.6000<br />
Distance Uncertainty (1+0.0005% x distance = data point spacing)<br />
Trace File Format Bellcore GR-196 Version 1.1<br />
Trace File Storage Media Internal flash memory, USB flash drive, downloadable<br />
from OTDR directly to PC<br />
Trace File Storage Capacity Internal 1000 fibers<br />
OTDR Modes<br />
Full Auto, Real Time, Expert<br />
Tool Free Adapters Modular cleanable SC/ST/FC/LC<br />
OTDRs<br />
M200 Handheld OTDR<br />
The Noyes M200 offers unmatched OTDR capabilities in a handheld<br />
package weighing less than 1 kg (2 lb). Multimode, Single-mode, and<br />
‘Quad’ wavelength models are offered. With short dead zone and<br />
intermediate range specifications, the M200 is ideal for Tier 2 testing<br />
of premises (building and campus) networks or certification and<br />
troubleshooting of FTTX PON networks. And its bright, transflective<br />
display makes it suitable for both indoor and outdoor operation.<br />
Features:<br />
- Handheld, 0.9kg (2lbs)<br />
- 22dB(MM), 26dB(SM) dynamic<br />
range<br />
- Integrated VFL (650mm)<br />
- Tool-free, switchable adapters<br />
- Transflective (indoor/outdoor)<br />
touchscreen display<br />
- USB Host and Function ports<br />
Applications:<br />
- Tier 2 testing of premises<br />
networks<br />
- FTTX PON certification and<br />
troubleshooting<br />
- Fast fault location<br />
- Splice verification<br />
- Network Documentation<br />
The M200 is based on a new hardware/software platform that supports automatic and manual setup,<br />
precision event analysis, dual-wavelength testing, rich file naming and folder setup, 6- hour battery life,<br />
internal and removable media data storage, and USB connectivity. Test ports are equipped with tool-free<br />
adapters, which can be changed in seconds. A custom-designed polycarbonate case and shock-absorbing<br />
boot make it our most rugged OTDR ever. Results are saved as industry standard .SOR files, which can be<br />
viewed, printed, and analyzed on a PC using free-ware available to you and your customers. Unit firmware,<br />
user settings, and test results are saved in non-volatile memory. Thus the M200 may be stored with<br />
battery removed for an extended period of time and still be up and running in seconds when needed.<br />
New Feature: By using a standard USB Flash Drive to transfer traces, the user no longer needs a USB<br />
Cable, ActiveSync or a Compact Flash reader. Thousands of files will fit on a 64 MB.<br />
M200-K-QUAD 850/1300nm Multimode & 1310/1550nm Singlemode OTDR $7935.00<br />
M200-K-SM 1310/1550nm Singlemode OTDR $5290.00<br />
M200-K-MM 850/1300nm Multimode OTDR $5555.00<br />
General M200 Handheld OTDR Specifications<br />
Multimode<br />
Emitter Type<br />
Laser<br />
Safety Class<br />
Singlemode<br />
Class I FDA 21 CFR 1040.10 & 1040.11 IEC<br />
EN608825-1:2007-03<br />
Center Wavelengths 850/1300nm 1310/1550nm<br />
Wavelength Tolerance ± 20/±30nm ± 20/±30nm<br />
Dynamic Range (SNR=1) 22dB 26dB<br />
Event Dead Zone 1.5m 1.5m<br />
Attenuations Dead Zone 9m 9m<br />
Pulse Widths 10, 30, 100, 300ns, 1,<br />
3µm<br />
10, 30, 100, 300ns, 1,<br />
3, 10µm<br />
Range Settings 250m to 32km 250m to 208km<br />
Data Points Up to 16,000 Up to 16,000<br />
Data Point Spacing 0.25m (range ≤ 4km) Range/16000 (range ≥ 8km)<br />
Group Index of Refraction 1.4000 to 1.6000<br />
Distance Uncertainty ± (1+0.005% x distance + data point spacing<br />
Trace File Format Bellcore GR-196<br />
Trace File Storage Medium thousands on compact flash or USB flash drive<br />
Trace File Storage Capacity > 100 internal; thousands on compact flash or<br />
USB drive<br />
Trace File Transfer to PC<br />
USB flash drive type 1.1, Compact flash or mini usb<br />
cable with ActiveSync<br />
42<br />
TM<br />
<strong>Datacomtools</strong>.com<br />
Free Ground Shipping on Orders over $99.00. In the contiguous states, certain items may not apply