05.07.2015 Views

A223 Action on Hearing Loss Smoke Alarm

A223 Action on Hearing Loss Smoke Alarm

A223 Action on Hearing Loss Smoke Alarm

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

5.2 SHORTENING THE SMOKE DETECTOR CABLE<br />

IMPORTANT: This must always be carried out with the SMOKE<br />

DETECTOR 1 cable unplugged from the JUNCTION<br />

BOX 3 !<br />

In some cases it may be necessary to locate the SMOKE<br />

DETECTOR 1 much closer than 10m from the<br />

BASE UNIT 2 .<br />

In this case the 10m cable supplied can be shortened,<br />

if you wish.<br />

1. Open the cover of the SMOKE DETECTOR 1 and locate<br />

the screw terminal that the cable is attached to.<br />

2. Remove the cable from the screw terminal by unscrewing the<br />

terminal screws.<br />

3. Using wire cutters, shorten the standard 10m cable to the<br />

required length.<br />

4. Strip and rec<strong>on</strong>nect the cable ends to the screw terminal,<br />

making sure that the c<strong>on</strong>necti<strong>on</strong>s are tightened correctly.<br />

5. Make sure that you rec<strong>on</strong>nect the wires correctly, c<strong>on</strong>necting<br />

like to like (i.e positive to positive, negative to negative).<br />

Note: The negative wire is easily identified, it has a black strip.<br />

17

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!