5.2 SHORTENING THE SMOKE DETECTOR CABLE<br />
IMPORTANT: This must always be carried out with the SMOKE<br />
DETECTOR 1 cable unplugged from the JUNCTION<br />
BOX 3 !<br />
In some cases it may be necessary to locate the SMOKE<br />
DETECTOR 1 much closer than 10m from the<br />
BASE UNIT 2 .<br />
In this case the 10m cable supplied can be shortened,<br />
if you wish.<br />
1. Open the cover of the SMOKE DETECTOR 1 and locate<br />
the screw terminal that the cable is attached to.<br />
2. Remove the cable from the screw terminal by unscrewing the<br />
terminal screws.<br />
3. Using wire cutters, shorten the standard 10m cable to the<br />
required length.<br />
4. Strip and rec<strong>on</strong>nect the cable ends to the screw terminal,<br />
making sure that the c<strong>on</strong>necti<strong>on</strong>s are tightened correctly.<br />
5. Make sure that you rec<strong>on</strong>nect the wires correctly, c<strong>on</strong>necting<br />
like to like (i.e positive to positive, negative to negative).<br />
Note: The negative wire is easily identified, it has a black strip.<br />
17