The dedicaTed soluTion for moTion<br />
managemenT
Product description<br />
c-rad sentinel is an easy-to-use, laser based optical<br />
surface scanning system that monitors the patient for<br />
motion during treatment and optionally assists in quick<br />
re-positioning whenever a large movement has been<br />
detected.<br />
The system checks the patient’s position more than once<br />
every second with sub-millimeter accuracy. Being completely<br />
non-invasive, no markers will need to be placed on<br />
the patient or the couch. a detected deviation outside of set<br />
tolerances will clearly be indicated by an audible and visual<br />
alarm.<br />
The sentinel monitor in the control area will give a clear<br />
indication on what part of the patient has moved, which will<br />
assist the therapist in deciding whether the patient needs<br />
to be repositioned or the treatment can continue.<br />
Workflows<br />
Intra-fraction motion detection<br />
• The patient is set up according to tattoos and room<br />
lasers.<br />
• a cone-beam cT scan is performed and the resulting<br />
computed couch shift is applied.<br />
• The sentinel starts scanning the patient continuously,<br />
and will during the first breathing cycles record the<br />
initial position and normal respiratory range.<br />
• monitoring of the patient continues to detect any motion<br />
outside of the initial respiratory range.<br />
• Treatment delivery begins.<br />
• in case of motion outside of set tolerances, an audible<br />
and visual alarm will be triggered and the therapist can<br />
decide whether to stop the beam.<br />
With today’s advanced treatment techniques, detecting and reacting on<br />
intra-fraction patient motion has become more important than ever. Even<br />
so, this task is largely done the same way as decades ago, where the<br />
therapist is watching the patient on TV monitors connected to the in-room<br />
camera system. While large movements can be detected, gradual shifts in<br />
patient position are almost impossible to recognize.<br />
Patient positioning and intra-fraction motion detection<br />
• The patient is setup within 5 cm of the treatment position.<br />
• The sentinel scans the patient and computes the<br />
required couch shift, based on a reference position recorded<br />
during an earlier session. The couch shift is then<br />
applied manually or automatically.<br />
• The sentinel starts scanning the patient continuously,<br />
and will during the first breathing cycles record the<br />
initial position and normal respiratory range.<br />
• monitoring of the patient continues to detect any motion<br />
outside of the initial respiratory range.<br />
• Treatment delivery begins.<br />
• in case of motion outside of set tolerances, an audible<br />
and visual alarm will be triggered and the therapist can<br />
decide whether to stop the beam.<br />
• a sentinel positioning can be triggered to quickly find<br />
the required couch shift to bring the patient back in<br />
position and continue treatment.
Configurations<br />
Basic package<br />
The basic sentinel package consists of a single ceiling<br />
mounted scanner unit placed above the foot end of the<br />
couch, and a workstation Pc which runs the user-friendly<br />
application software. The system can be operated both<br />
from within the treatment room using the sentinel<br />
remote control, or by using the mouse and keyboard in the<br />
control area.<br />
Options:<br />
DICOM and patient synchronization<br />
With the dicom and patient synchronization option enables<br />
import of patient data from the treatment planning system,<br />
thus minimizing manual data entry. in the treatment room,<br />
the sentinel will also interface to the r&V or linac software<br />
to detect the currently selected patient. This means<br />
that the correct settings will be called up automatically,<br />
without the need for manual selection.<br />
Patient positioning<br />
adding the option for patient positioning will enable the<br />
system to compare the current patient position against<br />
a previously stored reference position and produce the<br />
required couch shift to bring the patient to the treatment<br />
position. depending on the capabilities of the r&V, linac,<br />
and couch control systems, the computed couch correction<br />
may be applied automatically through auto-setup.<br />
Networking<br />
adding the networking option will keep all the patient data<br />
in a central database, ensuring that the correct settings<br />
are always available even if the patient needs to be treated<br />
in a different room. it is possible to add more sentinel<br />
client workstations to the network so that data can be<br />
accessible from e.g. the treatment planning room or<br />
physicists’s office.<br />
4DCT<br />
(Works in progress. not for sale in the us)<br />
With this option, a sentinel system installed in the cT<br />
room will be usable as a respiratory gating device for<br />
prospectively gated as well as retrospectively gated imaging<br />
(aka 4dcT) on modern oncology cTs. The respiratory<br />
motion is measured optically on the patient’s skin, without<br />
requiring any markers or other equipment to be placed on<br />
the patient. Two detection points can be selected which<br />
enables both thoracic and abdominal breathing motion to<br />
be detected in parallel.
WORLD WIDE SERVICE AND SUPPORT<br />
complies with the iec-60825-1<br />
standard, safety of laser products.<br />
complies with fda performance<br />
standards for laser products except for<br />
deviations pursuant to laser notice<br />
no. 50, dated June 24, 2007.<br />