Controllers - AGCO Parts
Controllers - AGCO Parts Controllers - AGCO Parts
CCS100 Thermal Transfer Unit Converts anhydrous vapor to liquid for control and accurate application purposes. It installs easily in the NH3 line, without welding or seals. Requires minimal maintenance and cleaning even with stabilized nitrogen. This liquid-to-liquid exchanger requires no vapor lines to the knives. Application rates over 4200 lbs. per hour may require two Thermal Transfer Units. | Part | Description | | AG711541 | Thermal Transfer Unit | Controllers CCS Control with Equalizer NH3 Kit | Part | Description | | AG717224 | CCS 100 Control with | | | Wheel Sensor and EQUALIZER Kit | | AG717223 | CCS 100 Control and | | | EQUALIZER Kit Less Speed Sensor | CCS100 System Control Console CCS100 Control Valve Features a new stainless steel ball valve. Provides high-speed response as ground speed changes (full open to full close in less than two seconds). May be used with liquids, slurries, NH3 or stabilized N. Provides full, no-leak shut off. A hydraulic control and driver can be used to regulate hydraulic motor speed. | Part | Description | | AG711429 | Actuator Only, 3/4" and 1" | | AG711539 | 3/4" Valve Only | | AG711430 | 1" Valve Only | | AG711094 | 2" Valve and Actuator | | AG609787 | 3" Valve and Actuator | | AG609003 | Actuator Valve - driver | | AG609250 | Hydraulic Control Valve 30 GPM with 20 ft Cord | A powerful minicomputer that compares ground speed and application rate and regulates the control valve to maintain a constant rate. This pressure-based system ensures proper spray pattern. Provides a dual digital readout of pressure and pressure per acre (flow rate and lbs. per acre for NH3 and stabilized N application). Features a non-volatile memory so constants will remain stored without power. Provides a plugged nozzle indicator when the optional flow meter is added. A convenient remote system control modules mounts in any convenient location. | Part | Description | | AG711093 | CCS 100 Console | | AG609004 | CCS 100 Remote Switch | 48
CCS100 Flow Sensor Provides information to console for NH3 application rate display. As an optional component for liquid control systems, detects plugged nozzle conditions. | Part | Description | | AG711540 | Flow Sensor | CCS100 Pressure Sensor Designed for reliability and extended pressure range. Liquid 0-100 PSI. CCS100 System Control Components | Part | Description | | AG711309 | CCS100 Wire Harness | | AG711542 | Implement Wire Harness | CCS100 System "Y" Splitter Cables To operate Dickey-john controls on tractors with factory-installed radar gun. | Part | Description | | AG714220 | Cable for Cat Challenger 75C Series | | Part | Description | | AG710420 | Transducer, Nozzle Pressure | CMS100 Custom Monitoring System The CMS100 can be added to the CCS100 liquid or anhydrous control systems to give the operator a fullyinstrumented system. The CMS100 provides touch-switch selection of readouts of actual application rate in gallons per acre, vehicle speed, spraying pressure, gallons applied per field, total gallons applied, gallons remaining in tank, field area covered, total area covered, and area covered per hour. This CMS100 system is meant to be used as a companion unit to the CCS100 to achieve a fully instrumented system. It includes a Y cable that adapts to the DICKEY-john radar speed sensor. Note: The CMS100 is a monitoring instrument and not a controller. | Part | Description | | AG711358 | CMS100 Custom Monitoring System | DjRVS II Radar Sensor A microwave sending and receiving unit that measures true ground speed under actual field conditions. Includes mounting hardware. Controllers | Part | Description | | AG711009 | Dickey-john Radar Sensor with Mounting Bracket | If you live in northern climates where freezing can occur, remember to winterize your sprayer to prevent damage to sprayer components. 49
- Page 1 and 2: AGCO Application Equipment Parts &
- Page 3 and 4: Introduction and Contents Welcome t
- Page 5 and 6: Spray Tips, Drift Guard . . . . .13
- Page 7 and 8: Foam Tank Cleaner Ag-Chem foam tank
- Page 9 and 10: Gauge Adapter Brass 1/8"(M) x 1/4"(
- Page 11 and 12: Manual Booms The Mec Series is a ma
- Page 13 and 14: Vertical Bulk Storage Tanks Ace-ROT
- Page 15 and 16: Pallet Paks Pallet Pak units are de
- Page 17 and 18: Cradles and Bands for Round Horizon
- Page 19 and 20: Cone Bottom Tanks Cone Bottom Tanks
- Page 21 and 22: Safety Tank FDA approved, 9-gallon,
- Page 23 and 24: Banjo Tank Fittings Double threaded
- Page 25 and 26: Falcon ® II Controller The Falcon
- Page 27 and 28: Envizio PRO The Envizio Pro multi-f
- Page 29 and 30: CAN SmarTrax/SmarTrax 3D CAN SmarTr
- Page 31 and 32: AutoBoom CAN UltraGlide AutoBoom Ul
- Page 33 and 34: SmartBoom Ravens SmartBoom is a sim
- Page 35 and 36: Switch Pro Switch Pro provides a st
- Page 37 and 38: SCS 440 and 450 Carrier Control Aut
- Page 39 and 40: SCS-Sidekick Direct Injection Syste
- Page 41 and 42: Raven Control Cables | Part | Descr
- Page 43 and 44: Calc-An-Acre II The Calc-An-Acre II
- Page 45 and 46: RFM60S Flowmeter RFM100 Repair Part
- Page 47 and 48: RFM400 Repair Parts Accu-Flow Kits
- Page 49: CCS100 Custom Control System Liquid
- Page 53 and 54: AA144A DirectoValve Repair Parts No
- Page 55 and 56: Raven ® Electric Shut-Off Valves 1
- Page 57 and 58: QC3-Stack Valves Stack up to 10 val
- Page 59 and 60: Polypropylene Union Ball Valve A qu
- Page 61 and 62: All Stainless Steel Valves A qualit
- Page 63 and 64: Centerline Butterfly Valves Notes:
- Page 65 and 66: ACE 150 Series Repair Parts Note: V
- Page 67 and 68: ACE FMC-HYD Repair Parts Repair Par
- Page 69 and 70: SpraCoupe Replacement Pump Ace's ne
- Page 71 and 72: PTO Belt Driven Pumps Cast iron 1-1
- Page 73 and 74: Hypro Series 9303P Pumps Hydraulica
- Page 75 and 76: 9000 Series Centrifugal Pump Repair
- Page 77 and 78: Torque Bar and Chain Anchors pump d
- Page 79 and 80: Hypro D135 Diaphragm Pump Hypro low
- Page 81 and 82: 6500 Series Roller Pump • Max flo
- Page 83 and 84: Hydraulically-Driven Pressure Washe
- Page 85 and 86: 12V Motor Speed Control Controller
- Page 87 and 88: Repair Parts for Scot 2" Pump Scot
- Page 89 and 90: Ace GE-Series Pumps Ace's GE-Series
- Page 91 and 92: Type 316 Stainless Steel Pedestal P
- Page 93 and 94: Pacer Hand Pump Heavy-duty, double-
- Page 95 and 96: GREEN XLPE for Chemical Transfer Fo
- Page 97 and 98: Dry Poppet Coupling Type B Female c
- Page 99 and 100: Viton Gaskets Note: AG009979 gasket
CCS100 Thermal Transfer Unit<br />
Converts anhydrous vapor to liquid for control and accurate application purposes. It installs easily in the NH3 line, without<br />
welding or seals. Requires minimal maintenance and cleaning even with stabilized nitrogen. This liquid-to-liquid<br />
exchanger requires no vapor lines to the knives. Application rates over 4200 lbs. per hour may require two Thermal<br />
Transfer Units.<br />
| Part | Description |<br />
| AG711541 | Thermal Transfer Unit |<br />
<strong>Controllers</strong><br />
CCS Control with Equalizer NH3 Kit<br />
| Part | Description |<br />
| AG717224 | CCS 100 Control with |<br />
| | Wheel Sensor and EQUALIZER Kit |<br />
| AG717223 | CCS 100 Control and |<br />
| | EQUALIZER Kit Less Speed Sensor |<br />
CCS100 System Control Console<br />
CCS100 Control Valve<br />
Features a new stainless<br />
steel ball valve. Provides high-speed response as<br />
ground speed changes (full open to full close in<br />
less than two seconds). May be used with liquids,<br />
slurries, NH3 or stabilized N. Provides full, no-leak shut off. A hydraulic<br />
control and driver can be used to regulate hydraulic motor speed.<br />
| Part | Description |<br />
| AG711429 | Actuator Only, 3/4" and 1" |<br />
| AG711539 | 3/4" Valve Only |<br />
| AG711430 | 1" Valve Only |<br />
| AG711094 | 2" Valve and Actuator |<br />
| AG609787 | 3" Valve and Actuator |<br />
| AG609003 | Actuator Valve - driver |<br />
| AG609250 | Hydraulic Control Valve 30 GPM with 20 ft Cord |<br />
A powerful minicomputer<br />
that compares ground<br />
speed and application rate and regulates<br />
the control valve to maintain a<br />
constant rate. This pressure-based<br />
system ensures proper spray pattern. Provides a dual digital readout of<br />
pressure and pressure per acre (flow rate and lbs. per acre for NH3 and<br />
stabilized N application). Features a non-volatile memory so constants<br />
will remain stored without power. Provides a plugged nozzle indicator<br />
when the optional flow meter is added. A convenient remote system<br />
control modules mounts in any convenient location.<br />
| Part | Description |<br />
| AG711093 | CCS 100 Console |<br />
| AG609004 | CCS 100 Remote Switch |<br />
48