<strong>Thermal</strong> <strong>Solutions</strong> ProtoNode Start Up guide Page 3 of 32<br />

TABLE OF CONTENTS<br />

1 Introduction ........................................................................................................................................... 5<br />

1.1 BTL Mark – BACnet Testing Laboratory...................................................................................................... 5<br />

1.2 LonMark Certification ................................................................................................................................... 5<br />

2 Bacnet/LONWorks Setup through Protocessor Protonode RER/LER ..................................................... 6<br />

2.1 Installation steps for the customer ................................................................................................................. 6<br />

2.2 Record Identification Data ............................................................................................................................. 6<br />

2.3 Configure the A, B, and S Bank of DIP Switches ......................................................................................... 7<br />

2.3.1 Setting Device Node-ID’s and Serial Settings of the TSBC <strong>Controller</strong>s .................................................. 7<br />

2.3.2 Setting the MAC Address (DIP Switch A0 – A7) for BACnet MS/TP ....................................................... 7<br />

2.3.3 Setting the Node-ID/Device Instance for Metasys N2, BACnet/IP, and Modbus TCP ............................ 7<br />

2.3.4 Setting the Serial Baud Rate (DIP Switch B0 – B3) for BACnet MS/TP .................................................. 8<br />

2.3.5 Using S0 – S3 bank of DIP Switches Selects Field Protocol, Auto-Discovers TSBCS <strong>Controller</strong>s, and<br />

loads Configuration File ....................................................................................................................................... 8<br />

2.3.6 Auto-Discover All <strong>Thermal</strong> <strong>Solutions</strong> <strong>Boiler</strong> <strong>Controller</strong>s, Build and Automatically Loads<br />

Configuration File ................................................................................................................................................. 9<br />

3 Interfacing the ProtoNode to <strong>Thermal</strong> <strong>Solutions</strong> TSBC <strong>Boiler</strong> controller .............................................. 10<br />

3.1 ProtoNode RER and LER showing connection ports .................................................................................. 10<br />

3.2 Wiring Connections to ProtoNode RER and LER ....................................................................................... 10<br />

3.2.1 Connecting TSBC <strong>Boiler</strong> <strong>Controller</strong>s to the ProtoNode’s RS485 .......................................................... 11<br />

3.3 Wiring the ProtoNode RER to RS-485 Field Protocol ................................................................................ 12<br />

3.4 Wiring the ProtoNode LER Field Port to a LonWorks network .................................................................. 13<br />

3.5 Power-Up the ProtoNode RER or LER ....................................................................................................... 13<br />

3.6 Commissioning the ProtoNode LER on a LonWorks network .................................................................... 14<br />

4 Connect the ProtoNode’s Web GUI to Setup ip Address for BACnet/IP ................................................ 15<br />

4.1 Connect the PC to the ProtoNode via the Ethernet port ............................................................................... 15<br />

4.2 Use the ProtoNode Web GUI to Connect to the ProtoNode ........................................................................ 16<br />

4.3 Set IP Address for BACnet/IP or Modbus TCP ........................................................................................... 16<br />

Appendix A. Troubleshooting Tips if the Unit is Not Working ..................................................................... 18<br />

Appendix A.1. Take Log With Our FieldServer Utilities ........................................................................................ 18<br />

Appendix A.2. LED Diagnostics for Modbus RTU Communications between the ProtoNode and the TSBC ..... 21<br />

A.2.1 ProtoNode RER LEDs ............................................................................................................................... 21<br />

A.2.2 ProtoNode LER Main Board LEDs ........................................................................................................... 21<br />

Appendix B. Vendor Information ................................................................................................................. 22<br />

Appendix B.1. <strong>Thermal</strong> <strong>Solutions</strong> TSBC Modbus RTU COM Settings .................................................................. 22<br />

Appendix B.2. MAC Address DIP Switch Settings For BACnet MS/TP ................................................................ 22<br />

Appendix B.3. TSBC Modbus RTU Mappings to BACnet MSTP and BACnet IP. ............................................... 27<br />

Appendix B.4. TSBC Modbus RTU Mappings to LonWorks. ................................................................................ 29<br />

Appendix C. Reference................................................................................................................................. 31<br />

Appendix C.1. Specifications .................................................................................................................................. 31<br />

Appendix C.1.1. Compliance with UL Regulations ........................................................................................... 31<br />

Appendix D. Limited 2 year Warranty ......................................................................................................... 32<br />

ProtoCessor 1991 Tarob Court Milpitas, California 95035 USA Web: www.protocessor.com<br />

Tel: (408) 964 4444 Fax: (408) 964 4425 <strong>To</strong>ll Free: (800) 317 8319 x141 email: support@protocessor.com