4.7 COOL DOWN LEAKAGE<br />

<strong>AAC</strong> <strong>SPECIFICATION</strong> <strong>418002</strong><br />

<strong>HYDRAULIC</strong> <strong>HOSE</strong> & FITTINGS FOR USE IN<br />

COAL MINING APPLICATIONS<br />

<strong>ISSUE</strong> 3<br />

COPYRIGHT<br />

All hose end fittings must meet Class 0 cool down leakage performance as per SAE<br />

J1176.<br />

TABLE 2: <strong>HYDRAULIC</strong> SUCTION, PRESSURE AND RETURN LINES<br />

DASH<br />

SIZE<br />

NOMINAL BORE<br />

MM INCH<br />

DESIGN<br />

WORKING<br />

PRESSURE<br />

(MPA)<br />

MINIMUM BEND<br />

RADIUS (MM)<br />

<strong>HYDRAULIC</strong> SUCTION LINES<br />

IMPULSE PERFORMANCE<br />

(CYCLES)<br />

-12 19 ¾ 2,0 64 N/A<br />

-16 25 1 1,7 76 N/A<br />

-20 31 1 ¼ 1,4 102 N/A<br />

-24 38 1 ½ 1,0 125 N/A<br />

-32 51 2 0,7 152 N/A<br />

<strong>HYDRAULIC</strong> PRESSURE AND RETURN LINES 2 BRAID<br />

-4 6 ¼ 40,0 100 200K @ 133% WP<br />

-6 10 ⅜ 34,5 130 200K @ 133% WP<br />

-8 12 ½ 29,5 180 200K @ 133% WP<br />

-12 19 ¾ 21,5 240 200K @ 133% WP<br />

-16 25 1 17,5 300 200K @ 133% WP<br />

-20 31 1 ¼ 15,5 420 200K @ 133% WP<br />

-24 38 1 ½ 12,5 500 200K @ 133% WP<br />

-32 51 2 90,0 630 200K @ 133% WP<br />

<strong>HYDRAULIC</strong> EXTRA HIGH PRESSURE LINES 2 BRAID<br />

-6 10 ⅜ 34,5 130 500K @ 133% WP<br />

-8 12 ½ 29,5 180 500K @ 133% WP<br />

-12 19 ¾ 27,6 240 500K @ 133% WP<br />

-16 25 1 36,0 300 500K @ 133% WP<br />

<strong>HYDRAULIC</strong> HIGH PRESSURE LINES 4 SPIRAL<br />

-6 10 ⅜ 49,0 180 400K @ 133% WP<br />

-8 12 ½ 42,0 230 400K @ 133% WP<br />

-10 16 ⅝ 40,0 250 400K @ 133% WP<br />

<strong>AAC</strong>_SPEC_<strong>418002</strong>03 APPROVED 8 May 1991 Page 6 of 10<br />

Anglo Technical Division accepts no liability for any damage whatsoever that may result from the use of this material or<br />

the information contained therein, irrespective of the cause and quantum thereof.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!