West Penn Power AMENDED Program Year 3 Final Annual Report
West Penn Power AMENDED Program Year 3 Final Annual Report
West Penn Power AMENDED Program Year 3 Final Annual Report
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Table 7-2: Limited Income Energy Efficiency <strong>Program</strong> (LIEEP) Sampling Strategy for PY3<br />
Stratum<br />
Low Income<br />
Home<br />
Check-up<br />
<strong>Program</strong><br />
Total<br />
Strata<br />
Boundaries<br />
Population<br />
Size<br />
Assumed<br />
Coefficient of<br />
Variation (Cv)<br />
or Proportion<br />
in Sample<br />
Design<br />
Target Levels<br />
of Confidence<br />
& Precision<br />
. n/a 5,020 0.5 90%, +/- '<br />
, 22<br />
n/a<br />
7.9%<br />
5,020 0.5 90%, +/-<br />
7.9%<br />
Target<br />
Sample Size<br />
Achieved<br />
Sample Size<br />
Evaluation Activity<br />
105 115 Phone survey, savings<br />
calculations review,<br />
and tracking file<br />
review<br />
105 115<br />
Table 7-3: PY3 Limited Income Energy Efficiency <strong>Program</strong> (LIEEP) Summary of Evaluation Results for<br />
Energy<br />
Observed<br />
Coefficient of<br />
Stratum<br />
<strong>Report</strong>ed Gross<br />
Energy Savings<br />
Energy Realization<br />
Rate<br />
Variation (C v) or<br />
Proportion<br />
Relative Precision<br />
Verified Gross<br />
Energy Savings<br />
Low Income<br />
Home Checkup<br />
8,118 80.0% 0.4 0.05 6,494<br />
<strong>Program</strong> Total 8,118 80.0% 0.4 0.05 6,494<br />
Table 7-4: PY3 Limited Income Energy Efficiency <strong>Program</strong> (LIEEP) Summary of Evaluation Results for<br />
Demand<br />
Observed<br />
Stratum<br />
<strong>Report</strong>ed Gross<br />
Demand Reduction<br />
Demand<br />
Realization Rate<br />
Coefficient of<br />
Variation (CJ or<br />
Proportion<br />
Relative Precision<br />
Verified Gross<br />
Demand<br />
Reduction<br />
Low Income<br />
Home Checkup<br />
1.41 80.0% 0.4 0.05 1.13<br />
<strong>Program</strong> Total 1.41 80.0% 0.4 0.05 1.13<br />
7.3 Impact Evaluation Net Savings<br />
Act 129 compliance is based on gross savings, but the Company's Evaluators are presently finalizing a<br />
portfolio-level net to gross survey to inform the program planning for Phase II of Act 129. The<br />
evaluation of the legacy FirstEnergy companies included net-to-gross research based on <strong>Program</strong> <strong>Year</strong> 3<br />
22<br />
Strata boundaries for this sampling design are not applicable as a random sample was pulled for each measure's<br />
population that included all participants.<br />
<strong>West</strong> <strong>Penn</strong> <strong>Power</strong> Company | Page 55