Sealed <strong>Quotation</strong> are invited from reputed contractor for L.P.G. Cremator at<br />
Majiwada Smashanbhoomi for below mentioned work from 25.03.2013 to<br />
01.04.2013 upto 16.00Hrs. in <strong>of</strong>fice hours in the <strong>of</strong>fice <strong>of</strong> Executive Engineer<br />
Officer, P.W.Department, Majiwada Manpada Ward Office, 1 st Floor, <strong>Thane</strong><br />
<strong>Municipal</strong> <strong>Corporation</strong>, <strong>Thane</strong> – W.<br />
No Item Description Rate Unit Amount<br />
Rs.<br />
1 Cremator Furnace:<br />
Cremator furnace shell consisting <strong>of</strong><br />
combustion chamber dully lined with<br />
refractory bricks <strong>of</strong> high alumina<br />
content <strong>of</strong> over 40 % AL2O3 and<br />
backed by insulating bricks, with<br />
back up insulation <strong>of</strong> 25 mm thick<br />
ceramic wool provided inside outer<br />
cover panels and operator view glass<br />
and body loading at 900 mm height<br />
from the ground level. Heavy duty<br />
rolled M.S. sections and good quality<br />
fabrication with hearth provided with<br />
refractory cast slabs. Wielding done<br />
up side down to prevent leakages and<br />
225 mm size taper refractory bricks<br />
are used to provide the crown or arch<br />
weighing about 8.5 tons etc.<br />
complete. Outer dimensions <strong>of</strong> the<br />
cremator are 3.35 M long, 1.52 M<br />
wide and 1.83 M tall. Inside<br />
dimensions <strong>of</strong> the cremator are 2.44<br />
M long, 0.99 M wide and 0.60 M tall<br />
necessary N.O.C. & permissions<br />
taken from various department for<br />
L.P.G. cremator installation &<br />
operation.<br />
1<br />
unit<br />
2 Burner:<br />
Gas burner <strong>of</strong> North American design<br />
suitable for 30 kgs/hr capacity<br />
345000 Kgcal/ Hour for LPG with<br />
Auxiliary burner complete with<br />
refractory burner blocks <strong>of</strong> 300 mm x<br />
300 mm, atomizing arrangement with<br />
gas and air lines duly connected etc.<br />
complete<br />
3 Blowers:<br />
Blowers with air lining flange welded<br />
construction. Blowers are<br />
interconnected to facilitate supplying<br />
air from either blowers to the burner<br />
in case <strong>of</strong> emergency. The blowers<br />
2<br />
units<br />
3<br />
units
are fitted 3 phase, 3 HP induction<br />
electric motors and are <strong>of</strong> 300 CFM<br />
capacity with over load relays and<br />
contactors and separate switches and<br />
fuses etc. complete<br />
4 Reticulation:<br />
Gas reticulation for supplying the LP<br />
Gas to the cremator from the gas<br />
cylinders storage shed with pig tails,<br />
regulators for 48 cylinders, shut <strong>of</strong>f<br />
valves, ‘C” class quality seamless<br />
pipe <strong>of</strong> 25 mm dia, pressure gauges,<br />
change over valve, solenoid valves,<br />
shut <strong>of</strong>f valves etc. complete<br />
5 Door Assembly:<br />
Door assembly lined like the main<br />
furnace body <strong>of</strong> the cremator with<br />
1.5” thich asbestos rope as sealent<br />
with male female refractory seal.<br />
Supported on 3 nos Plummer blocks,<br />
with counter weight type<br />
arrangement and chain pulley blocks<br />
for easy operation. Door weighs 0.5<br />
tones etc. complete<br />
6 Body loading mechanism:<br />
Body loading mechanism with 10<br />
guage high carbon steel metal mesh<br />
belt with sprocket and chain<br />
arrangement with a geared reduction<br />
motor and separate traveling Crain<br />
type cable suspended from above for<br />
ease in operation etc. complete<br />
7 Control panel:<br />
Electric control panel with 3 nos <strong>of</strong><br />
pilot lamps, 3 MCB’s, 100 amps bus<br />
bar, and one number <strong>of</strong> temperature<br />
indicator <strong>of</strong> digital dancing type<br />
characters with contactors and relays<br />
for each motor. Separately in M.S.<br />
fabricated unit dully wired etc.<br />
complete<br />
8 Chimney:<br />
30 Meter self supporting type M.S.<br />
chimney with pilot lamps, lightning<br />
arrestor, dully painted with<br />
temperature resistant (400 Degree C)<br />
900 mm dia at bottom and 300 mm<br />
on top. Each section joined with<br />
flanges etc. complete<br />
1<br />
unit<br />
1<br />
unit<br />
1<br />
unit<br />
1<br />
unit<br />
1<br />
unit
9 Water scrubber:<br />
S.S. 304 ventury type water scrubber<br />
<strong>of</strong> 1000 mm dia, with 5 mm thick<br />
S.S. 304 partition, necessary ducting<br />
up to the chimney. 6000 litres<br />
capacity water tank with pump and<br />
plumbing etc. complete<br />
10 Generator:<br />
7.5 KVA 3 phase generator duly<br />
coupled with alternator, mechanical<br />
change over, cabling, control panel ,<br />
air cooled 10 hp diesel engine with 4<br />
nos <strong>of</strong> anti vibratory mounts etc.<br />
complete<br />
11 Fire Fighting:<br />
Fire fighting equipments Dry<br />
Chemical Powder (DCP) 7.5 Kgs<br />
capacity 2 nos and Carbon Di Oxide<br />
(CO2) 2 nos. <strong>of</strong> fire extinguishers<br />
along with 2 nos. <strong>of</strong> sand buckets<br />
1<br />
unit<br />
1<br />
1<br />
12 Deposit <strong>of</strong> LPG cylinder 48<br />
13 LPG cylinder <strong>of</strong> 19 Kgs each 48<br />
14 Operation <strong>of</strong> the cremator for first 1<br />
year (12 months) from the date <strong>of</strong><br />
commissioning <strong>of</strong> the cremator.<br />
3 + 1= 4 workers and 1 supervisor<br />
15 TOTAL<br />
Per month<br />
12<br />
months<br />
The sealed <strong>Quotation</strong> will be opened in the <strong>of</strong>fice <strong>of</strong> Executive<br />
Engineer on 01.04.2013 at 16.30pm in front <strong>of</strong> Contractor or their<br />
representative if possible.<br />
Executive Engineer<br />
P.W.Department,<br />
Majiwada Manpada Ward Office,<br />
<strong>Thane</strong> <strong>Municipal</strong> <strong>Corporation</strong>, <strong>Thane</strong>