AR/GE/FE/U 80/80X <strong>Installation</strong> <strong>Manual</strong><br />
At this point, open the Status page from the unit’s NMS interface and ensure the Radio TX and RX<br />
is operating at 1000 Mbps for both radios.<br />
Click the refresh button a few times to ensure it is a good reading.<br />
If all indicators are good, then go to the next steps. If not, then go<br />
back to step 1 or contact BridgeWave Technical Support for<br />
assistance.<br />
5. Go to Statistics page and reset the stats for each radio end.<br />
6. Perform a ping test. Open two command line windows and ping the local and remote<br />
management agent. Factory default IPs are; 192.168.0.1 for lowband and 192.168.0.2 for<br />
highband and perform a ping to both ends and wait a few minutes, ensure you are getting<br />
responses from the local and remote management agents.<br />
7. Review statistics page results and ensure packets are being transmitted, received, and there<br />
are no excessive error conditions.<br />
8. If all is performing well, you must now 'disable' the <strong>Installation</strong>Auto Calibration option on<br />
the Setup page of each radio.<br />
3.10.2 <strong>Installation</strong> AutoCalibration Feature (AdaptRate models only):<br />
This feature should be disabled only after the radio system has been completely installed and<br />
calibrated as described above.<br />
In the NMS ‘Setup’ screen, select <strong>Installation</strong> AutoCalibration to ‘Disable’ and press the ‘Submit<br />
new Values button at the bottom of the screen<br />
Figure 3.10.21:<br />
<strong>Installation</strong> AutoCalibration Setting<br />
(AUTO CALIBRATION FINISHED)<br />