NEUTRAL<br />

J1 2<br />

SPDT SWITCH (ON-OFF-ON)<br />

S2<br />

120 V, 60 Hz<br />

FROM MAIN<br />

NOTE 1<br />

BK BK TO R = LOW SPEED EXCHANGE<br />

G<br />

BK TO G = HIGH SPEED EXCHANGE<br />

R<br />

NO CONNECTION = OFF<br />

J1 1<br />

J1 8<br />

1<br />

2<br />

3<br />

1<br />

2<br />

3<br />

7. WIRING DIAGRAM<br />

0 ! WARNING<br />

Risk of electrical shocks. Before performing any maintenance or servicing, always disconnect the unit from its<br />

power source. This product employs overload protection (fuse). A blown fuse indicates an overload or short-circuit<br />

situation. If the fuse blows, unplug the product from the outlet. Replace the fuse as per the servicing instructions<br />

(follow product marking for proper fuse rating) and check the product. If the replacement fuse blows, a short-circuit<br />

may be present and the product should be discarded or returned to an authorized service facility for examination<br />

and/or repair.<br />

S1<br />

A1<br />

FAN<br />

MOTOR<br />

NC MED<br />

HIGH<br />

OPTIONAL<br />

NOTE 6<br />

OVERRIDE SWITCH<br />

OVERRIDE SWITCH<br />

OVERRIDE LED<br />

J1 6<br />

J1 4<br />

J1 3<br />

LOW<br />

K2<br />

RELAY<br />

K1<br />

RELAY<br />

-17˚F<br />

-27˚C<br />

Connection<br />

Models : <strong>ERV</strong> <strong>Constructo</strong> 1.5 <strong>Quattro</strong><br />

<strong>ERV</strong> <strong>Constructo</strong> 2.0 <strong>Quattro</strong><br />

Logic<br />

M1<br />

NOTE 4<br />

M2<br />

DAMPER<br />

MOTOR<br />

J1 9<br />

K5<br />

RELAY<br />

X1 M1<br />

GY GY NEUTRAL<br />

O O HIGH<br />

G G FAN MOTOR<br />

NC R BL R MEDIUM<br />

LOW<br />

NOTE 2<br />

A 1<br />

2<br />

1<br />

B<br />

G<br />

C1<br />

BN<br />

BN<br />

R<br />

DEFROST<br />

TEMPERATURE<br />

SENSOR<br />

Y<br />

F F IOCOL<br />

3 4 5 7 8 9<br />

ABCDEFG<br />

-t˚<br />

J4<br />

R 1<br />

J3<br />

T 1<br />

ELECTRONIC ASSEMBLY<br />

GY<br />

R<br />

4<br />

7<br />

FAN<br />

FURNACE<br />

INTERLOCK<br />

KIT<br />

BN<br />

14<br />

J1<br />

3 2 1<br />

GY<br />

NOTES<br />

BL<br />

Y<br />

5, 6<br />

MODEL<br />

O 23˚F -5˚C 5˚F<br />

-15˚C<br />

M2<br />

6<br />

9<br />

BK<br />

W<br />

ELECTRONIC ASSEMBLY<br />

DAMPER MOTOR<br />

X2<br />

Y BL<br />

BL BL<br />

G G<br />

LINE VOLTAGE<br />

LOW VOLTAGE<br />

AND FIELD WIRING<br />

COLOR CODE<br />

FUNCTION TABLE RELAY<br />

K5<br />

K2<br />

K1<br />

MODE<br />

Intermittent<br />

Exchange Low<br />

Exchange High<br />

Defrost Cycle<br />

Off<br />

MAIN EARTHING<br />

POINT<br />

NC<br />

O<br />

R<br />

W<br />

W1<br />

G<br />

NO CONNECTION<br />

ORANGE<br />

RED<br />

WHITE<br />

YELLOW<br />

Y<br />

BLACK<br />

BLUE<br />

BROWN<br />

GREEN<br />

GRAY<br />

BK<br />

BL<br />

BN<br />

G<br />

GY<br />

120V 60 Hz<br />

W<br />

BK<br />

0 = Relay coil is de-energized<br />

1 = Relay coil is energized<br />

NEUTRAL<br />

LINE F1<br />

NOTE 7<br />

1<br />

0<br />

0<br />

1<br />

1<br />

0<br />

0<br />

1<br />

1<br />

0<br />

0<br />

1<br />

1<br />

1<br />

0<br />

NEMA-15P<br />

5-15 PLUG<br />

W<br />

COM NO<br />

BK BK<br />

DOOR INTERLOCK<br />

SWITCH<br />

S1<br />

NOTES<br />

5. FIELD INSTALLED OPTION: USE ONLY<br />

FACTORY-SUPPLIED KIT NO. 12658. FURNACE FAN<br />

CIRCUIT MUST BE CLASS 2 CIRCUIT ONLY.<br />

6. FIELD WIRING MUST COMPLY WITH APPLICABLE<br />

CODES, ORDINANCES AND REGULATIONS.<br />

7. SPECIFIED UL LISTED/CSA CERTIFIED LINE FUSE.<br />

LITTELFUSE (225 003), 2AG FAST-ACTING FUSE,<br />

224/225 SERIES<br />

RATING: 3 A.<br />

1. OPTIONAL CONTROLS AVAILABLE.<br />

2. FACTORY SET WIRING FOR BLOWER SPEED<br />

SELECTION IS HIGH AND LOW. MEDIUM SPEED CAN<br />

BE SELECTED INSTEAD OF LOW SPEED. DISCONNECT<br />

RED WIRE FROM THE MOTOR RED TAP AND CONNECT<br />

TO THE MOTOR BLUE TAP.<br />

3. IF ANY OF THE ORIGINAL WIRE, AS SUPPLIED, MUST<br />

BE REPLACED, USE THE SAME OR EQUIVALENT WIRE.<br />

4. USE FACTORY-SUPPLIED PROTECTIVE TUBING.<br />

VE0141A

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!