Essential supplies - AMCO Instruments, SRL
Essential supplies - AMCO Instruments, SRL
Essential supplies - AMCO Instruments, SRL
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
www.perkinelmer.com/<strong>supplies</strong><br />
Consumables and Accessories<br />
2006-2007 Catalog<br />
<strong>Essential</strong> <strong>supplies</strong><br />
for your analytical instruments<br />
Atomic Absorption<br />
Elemental Analysis<br />
Gas Chromatography<br />
Inductively Coupled Plasma – MS<br />
Inductively Coupled Plasma – OES<br />
Infrared Spectroscopy<br />
Liquid Chromatography<br />
Thermal Analysis<br />
UV Visible
Proven Quality, Reliability and Results<br />
Why Order from PerkinElmer?<br />
PerkinElmer Consumables and Accessories Reliability and Results<br />
In today’s demanding and often fast-paced laboratory<br />
environments, both scientists and administrators face<br />
a variety of challenges. Expanding workloads, limited<br />
resources, condensed timelines and increasingly<br />
complex regulations must be managed – without<br />
impact on accuracy and quality. Every element of<br />
your laboratory must be in sync… right down to the<br />
consumables for your instruments. This means that<br />
your suppliers must have systems in place that make your<br />
job easier by saving you time and money.<br />
Reliable performance<br />
At PerkinElmer, we’ve been serving a number of<br />
dynamic and diverse industries for over fifty years,<br />
and have a deep understanding of a laboratory’s<br />
requirements. With our precision-designed products,<br />
simple ordering process and best-in-class customer<br />
service, you can enjoy the peace of mind that comes<br />
with solid, reliable support. You’ll get the results you<br />
need – accurately and on time – with confidence.<br />
Plus, PerkinElmer consumables and accessories are<br />
guaranteed for PerkinElmer instruments, and many<br />
can be used with other manufacturers’ instruments.<br />
Superior quality and support<br />
We at PerkinElmer understand the ever-changing<br />
and evolving needs of your laboratory and business,<br />
and we continuously work to develop greater<br />
technological innovations to support your needs.<br />
Our instruments are backed by superior-quality<br />
service and support to provide you with peace of<br />
mind that your laboratory will operate smoothly.<br />
From routine sample testing to those “eureka”<br />
moments of unimaginable scientific breakthroughs,<br />
you can count on PerkinElmer to help you achieve<br />
your goals.<br />
How To Use This Catalog<br />
Product categories in the catalog are color-coded for quick<br />
reference (see below). Please use the Table of Contents on the<br />
next page to locate the product category you are looking for.<br />
Atomic Absorption<br />
Elemental Analysis<br />
Gas Chromatography<br />
Inductively Coupled Plasma – MS<br />
Inductively Coupled Plasma – OES<br />
Infrared Spectroscopy<br />
Liquid Chromatography<br />
Thermal Analysis<br />
UV Visible<br />
www.perkinelmer.com/<strong>supplies</strong><br />
See pages 2-4 for ordering information.<br />
On the edge of each page are color-coded VERTICAL<br />
bars that provide you with a quick reference for locating<br />
product categories AND the specific products you can find<br />
on that page. In addition, products are alphabetized by<br />
category, subcategory and family.<br />
For your reference there are two INDEX options:<br />
1. Alphabetical INDEX – See page 429<br />
2. Part Number INDEX – See page 406<br />
For advanced shopping features (such as accessing<br />
product availability dates or scheduling standing orders),<br />
refer to the ADVANCED Guide to Online Ordering in the back<br />
of this catalog on page 401.<br />
At PerkinElmer, we’ve made ordering easy. You can place<br />
your order by phone, fax, e-mail or mail. Simply contact<br />
your local office directly (see pages 2-4 for local office<br />
listings), and be sure to ask if online ordering is available<br />
in your area.
Table of Contents<br />
Product Category<br />
Page<br />
Atomic Absorption 5-72<br />
Elemental Analysis 73-84<br />
Gas Chromatography 85-184<br />
Inductively Coupled Plasma – MS 185-212<br />
Inductively Coupled Plasma – OES 213-236<br />
Infrared Spectroscopy 237-266<br />
Liquid Chromatography 267-332<br />
Thermal Analysis 333-376<br />
UV Visible 377-400<br />
ADVANCED Guide to Online Ordering 401-405<br />
INDEX: Alphabetical INDEX 429-443<br />
Part Number INDEX 406-428<br />
Terms and Conditions 444-448<br />
Table of Contents PerkinElmer Consumables and Accessories
Global Expertise... Local Support<br />
Personalized Service from a PerkinElmer Office Near You<br />
PerkinElmer Consumables and Accessories Local Support<br />
AFRICA<br />
ALGERIA • BENIN • BURKINA<br />
BURUNDI • CAMEROON<br />
CAPE VERDE<br />
CENTRAL AFRICAN REPUBLIC<br />
CHAD • COMOROS • CONGO<br />
DEMOCRATIC REPUBLIC OF CONGO<br />
DSCHIBUTI REPUBLIC<br />
EQUATORIAL GUINEA<br />
GABON • GAMBIA • GUINEA<br />
GUINEA – BISSAU • IVORY COAST<br />
MADAGASCAR • MALI • MAURITANIA<br />
MOROCCO • NIGER • REUNION<br />
RWANDA • SENEGAL • SEYCHELLES<br />
TOGO • TUNISIA • WESTERN SAHARA<br />
HTDS<br />
Tel: 33 1 64 86 28 28<br />
Fax: 33 1 69 07 69 54<br />
Email: philippe.lelievre@htds.fr<br />
ANGOLA • BOTSWANA • LESOTHO<br />
MALAWI • MAURITIUS<br />
MOZAMBIQUE • NAMIBIA<br />
SOUTH AFRICA • SWAZILAND<br />
ZAMBIA • ZIMBABWE<br />
Life and Analytical Sciences (PTY) Ltd.<br />
Tel: 27 (0)11 794 4430<br />
Fax: 27 (0)11 794 2160<br />
Email: sales@perkinelmersa.co.za<br />
BRITISH INDIAN OCEAN<br />
ERITREA • ETHIOPIA • GHANA<br />
KENYA • LIBERIA • NIGERIA<br />
SIERRE LEONE • SOMALIA<br />
SUDAN • TANZANIA<br />
UGANDA • WESTERN SAHARA<br />
HTDS-International<br />
Tel: 202 290 5306<br />
Fax: 202 290 5307<br />
Email: Nagui.Sadek@htds.fr<br />
IA<br />
ASIA<br />
BANGLADESH<br />
Overseas Marketing Corporation<br />
(Pvt.) Ltd<br />
Tel: 880-2-8154510<br />
Fax: 880-2-8156739<br />
Email: analytical@omcbd.com<br />
CHINA<br />
Beijing<br />
Tel: 86-10-6566 8166<br />
Fax: 86-10-6566 8155<br />
Chengdu<br />
Tel: 86-28-8678 2887<br />
86-28-8678 2662<br />
Fax: 86-28-8678 2522<br />
Guangzhou<br />
Tel: 86-20-8363 3176<br />
86-20-8363 3177<br />
86-20-8363 3179<br />
Fax: 86-20-8363 3579<br />
Shanghai<br />
Tel: 86-21-6391 2388<br />
Fax: 86-21-6391 2822<br />
Shenyang<br />
Tel: 86-24-2256 6158<br />
Fax: 86-24-2256 6153<br />
Wuhan<br />
Tel: 86-27-8732 2732<br />
86-27-8732 2826<br />
86-27-8712 8756<br />
Fax: 86-27-8732 2685<br />
HONG KONG<br />
Tel: 852-2620-1881<br />
Fax: 852-2620-1238<br />
INDIA<br />
PerkinElmer India (Pvt.) Ltd.<br />
Tel: 91 22 2570 1101<br />
91 22 2570 1102<br />
91 22 2570 1103<br />
Fax: 91 22 2570 1105<br />
Email: ramani.gopi@perkinelmer.com<br />
INDONESIA<br />
Tel: 62-21-55960248<br />
Fax: 62-21-55960247<br />
JAPAN<br />
Tel: 81-45-314-8381<br />
Fax: 81-45-314-5142<br />
KOREA<br />
Tel: 82-2-592-2998<br />
Fax: 82-2-3478-7979<br />
MALAYSIA<br />
Tel: 60-3-7958-1118<br />
Fax: 60-3-7958-5688<br />
NEPAL<br />
Associated Enterprises<br />
Tel: 977 1 4250934<br />
Fax: 977 1 4261744<br />
Email: info@asoent.com<br />
PAKISTAN<br />
Analytical Measuring Systems<br />
(Pvt.) Limited<br />
Tel: 92-21-5345581<br />
Fax: 92-21-5345582<br />
Email: amsana@cyber.net.pk<br />
Zahid.Mustafa@amspvtltd.com<br />
PHILIPPINES<br />
Tel: 63-2-6370180<br />
Fax: 63-2-9101168<br />
SINGAPORE<br />
Tel: 65-67799555<br />
Fax: 65-68726595<br />
SRI LANKA<br />
Colombo Traders<br />
Tel: 94 11 269 6121<br />
Fax: 94 11 269 8832<br />
Email: gpedris@sltnet.lk<br />
TAIWAN<br />
Kaohsiung<br />
Tel: 886-7-552-1030<br />
Fax: 886-7-554-3402<br />
Taipei<br />
Tel: 886-2-2764-7199<br />
Fax: 886-2-2764-7209<br />
THAILAND<br />
Tel: 662-3197901<br />
Fax: 662-3197900<br />
VIETNAM<br />
Saigon Instrumentation Joint<br />
Stock Company<br />
Tel: 844-747-2258<br />
Fax: 844-747-2260<br />
EUROPE<br />
ALBANIA • MACEDONIA<br />
Interlab d.o.o<br />
Tel: 389 2 3298 810<br />
Fax: 389 2 3118 279<br />
Email: interlab@mt.net.mk<br />
ARMENIA • AZERBAIJAN • BELARUS<br />
GEORGIA • KAZAKHSTAN<br />
KYRGYZSTAN • MOLDAVIA<br />
MONGOLIA • RUSSIA • TAJIKISTAN<br />
TURKMENISTAN • UKRAINE<br />
UZBEKISTAN<br />
Scheltec AG<br />
Tel: 7 095 935 8888<br />
Fax: 7 095 564 8787<br />
Email: info@scheltec.ru<br />
BOSNIA-HERZEGOVINA<br />
Analitika d.o.o<br />
Tel: 387 33 712 062<br />
Fax: 387 33 712 061<br />
Email: analitika_sa@bih.net.ba<br />
BULGARIA<br />
Chroma Ltd<br />
Tel: 359 2 952 0301<br />
Fax: 359 2 952 3784<br />
Email: chroma@spnet.net<br />
CROATIA<br />
Hebe d.o.o<br />
Tel: 385 1 2001 767<br />
Fax: 385 1 2001 724<br />
Email: zoran.tomaskovic@hebe.hr<br />
CYPRUS<br />
C & V Kriticos Suppliers Ltd<br />
Tel: 357 (22) 33 82 34<br />
Fax: 357 (22) 33 82 32<br />
Email: vasso@kriticos.com.cy<br />
CZECH REPUBLIC<br />
PE Systems s.r.o<br />
Tel: 420 241 430 534<br />
Fax: 420 241 430 535<br />
Email: pavel.choc@pesystems.cz<br />
DENMARK<br />
Tel: 808 8 42 36<br />
Fax: 808 8 42 37<br />
Email: cc.denmark@perkinelmer.com<br />
ESTONIA<br />
Peai-Est OU<br />
Tel: 372 7 383 330<br />
Fax: 372 7 383 360<br />
Email: lploom@hot.ee<br />
2 www.perkinelmer.com/<strong>supplies</strong>
Global Expertise... Local Support<br />
Personalized Service from a PerkinElmer Office Near You<br />
GREECE<br />
Antisel (A. Selidis Bros. S. A.)<br />
Tel: 30 210 779 5980<br />
Fax: 30 210 771 6932<br />
Email: aaidini@antisel.gr<br />
HUNGARY<br />
Per-Form Hungaria KFT<br />
Tel: 361 251 1116-2163-0230<br />
Fax: 361 251 1461<br />
Email: liptak.miklos@per-form.hu<br />
ICELAND<br />
Groco ehf<br />
Tel: 354 568 8533<br />
Fax: 354 568 0304<br />
Email: eirikur@groco.is<br />
LATVIA<br />
Adrona Sia<br />
Tel: 371 755 1894<br />
Fax: 371 755 1976<br />
Email: agris@adrona.lv<br />
LITHUANIA<br />
Linea Libera<br />
Tel: 370 5 2729 054<br />
Fax: 370 5 2729 067<br />
Email: paulius.jurgutis@mega.mii.lt<br />
MALTA<br />
Technoline Ltd<br />
Tel: 00356 21 344 345<br />
Fax: 00356 21 343 952<br />
Email: sdebono@technoline-mt.com<br />
NORWAY<br />
Tel: 800 18 854<br />
Fax: 800 18 855<br />
Email: cc.norway@perkinelmer.com<br />
POLAND<br />
PerkinElmer Polska Sp. z o.o.<br />
Tel: 48 22 607 05 60<br />
Fax: 48 22 607 05 70<br />
Email: andrzej.lechotycki@<br />
perkinelmer.com<br />
PORTUGAL<br />
ILC Instrumentos de<br />
Laboratório e Científicos Lda<br />
Tel: 351 21 782 60 30<br />
Fax: 351 21 782 60 39<br />
Email: ilc@ilc.pt<br />
REPUBLIC OF IRELAND AND<br />
NORTHERN IRELAND<br />
Foss Ireland<br />
Tel: 353 1 250 1100<br />
Fax: 353 1 250 1199<br />
Email: aoreilly@foss.ie<br />
ROMANIA<br />
SC Cromatec Plus Srl<br />
Tel: 40 21 316 2876<br />
40 21 316 2877<br />
40 21 316 2878<br />
Fax: 40 21 316 2876<br />
40 21 316 2877<br />
40 21 316 2878<br />
Email: office@cromatec.ro<br />
SLOVAKIA<br />
Medic Labor S.r.o<br />
Tel: 421 48 4155008<br />
Fax: 421 48 4155007<br />
Email: slaszlo@medic-labor.sk<br />
SLOVENIA<br />
Omega d.o.o<br />
Tel: 386 1 427 3213<br />
Fax: 386 1 427 3191<br />
Email: omega@omega.si<br />
SWEDEN<br />
Tel: 0200 - 88 75 20<br />
Fax: 0200 - 88 75 21<br />
Email: cc.sweden@perkinelmer.com<br />
SWITZERLAND<br />
Tel: 0800000015<br />
Fax: 0800000016<br />
Email: cc.switzerland@<br />
perkinelmer.com<br />
TURKEY<br />
Tetra Teknolojik Sistemler Ltd<br />
Tel: 90 212 212 5566<br />
Fax: 90 212 212 2829<br />
Email: istanbul@tetratek.com.tr<br />
UNITED KINGDOM<br />
Tel: 0800-89 60 46<br />
Fax: 0800-89 17 14<br />
Email: cc.uk@perkinelmer.com<br />
YUGOSLAVIA<br />
Interlab d.o.o<br />
Tel: 381 11 2404 385<br />
Fax: 381 11 2404 385<br />
Email: interlab@eunet.yu<br />
MIDDLE EAST<br />
BAHRAIN<br />
Yousuf Mahmood Husain<br />
Tel: 973 17 276176<br />
Fax: 973 17 275819<br />
Email: reji@ymh.com.bh<br />
GAZA STRIP • IRAQ<br />
JORDAN • LEBANON • LIBYA<br />
NEUTRAL ZONE (IQ/SA)<br />
SYRIA • WEST BANK<br />
PerkinElmer Egypt Limited<br />
Tel: 20 2 391 7261<br />
Fax: 20 2 392 1162<br />
Email: sadekna@ie-eg.com<br />
EGYPT<br />
Optima Scientific Egypt HTDS<br />
Tel: 202 418 8606<br />
Fax: 202 290 5307<br />
Email: sadekna@ie-eg.com<br />
ISRAEL<br />
Saifan Precision <strong>Instruments</strong> Ltd<br />
Tel: 972-3-7565000<br />
Fax: 972-3-7565007<br />
Email: john@saifan.co.il<br />
KUWAIT<br />
Bader Sultan & Bros Co. W.L.L.<br />
Tel: 965 43325555 (Ext. 326)<br />
Fax: 965 4334217<br />
Email: hisham@sultan.com.kw<br />
OMAN<br />
Business International Group L.L.C.<br />
Tel: 968 248 14752<br />
Fax: 968 248 13924<br />
Email: bigllc@omantel.net.om<br />
PALESTINE<br />
Techno-Line<br />
Tel: 972-2-6560077<br />
Fax: 972-2-6568796<br />
Email: a.imam@techno-line.com<br />
QATAR • UNITED ARAB EMIRATES<br />
Emphor FZCO<br />
Tel: 971 4 883 0233<br />
Fax: 971 4 883 0133<br />
Email: nilesh@emphor.biz<br />
SAUDI ARABIA<br />
Abdulrehman AlgoSaibi G.T.B.<br />
Tel: 966 672 0888<br />
Fax: 966 672 5664<br />
Email: ielhajj@algosaibi-gtb.com<br />
YEMEN<br />
Alfalah Trading<br />
Tel: 967 234 5073<br />
Fax: 967 234 0504<br />
Email: direct@alfalahye.net<br />
NORTH AMERICA<br />
CANADA<br />
Montreal, Quebec<br />
Tel: 514-937-9949<br />
800-293-4501 (Canada Only)<br />
Fax: 514-937-0777<br />
Email: orders.lscanada@<br />
perkinelmer.com<br />
Woodbridge, Ontario<br />
Tel: 905-851-4585<br />
800-561-4646<br />
Fax: 905-851-1814<br />
Email: orders.lscanada@<br />
perkinelmer.com<br />
COSTA RICA<br />
Analytical <strong>Instruments</strong>, S.A<br />
Tel: 506-272-47-00<br />
Fax: 506-272-97-00<br />
Email: vargasjf@ai.co.cr<br />
DOMINICAN REPUBLIC<br />
Inversiones Tecnicas<br />
Dominicanas S.A.<br />
Tel: 809-688-4927<br />
Fax: 809-682-9506<br />
EL SALVADOR<br />
Comercio Y Representaciones, S.A.<br />
Tel: (503) 2249-7777<br />
(503)-2249-7774<br />
Fax: (503) 2249-7788<br />
Email: coresa@salnet.net<br />
GUATEMALA<br />
Anaqui Analítica Química, S.A.<br />
Tel: 502-2433-6030<br />
502-2435-5360<br />
Fax: 502-435-4464<br />
Email: arturo-avila@salnet.net<br />
HONDURAS<br />
Representaciones Handal’s<br />
Tel: 504-220-4700<br />
Fax: 504-220-5426<br />
Email: rhandals@rhandals.hn<br />
MEXICO<br />
Tel: (52) 55-53-37-07-00<br />
(52) 55-56-51-70-77<br />
Fax: (52) 55-55-93-62-23<br />
Email:<br />
daniel.zavalza@perkinelmer.com<br />
NICARAGUA<br />
Sinter S.A.<br />
Tel: 505-278-0177<br />
Fax: 505-278-0252<br />
Email: amonge@sinter.com.ni<br />
Local Support PerkinElmer Consumables and Accessories<br />
For a complete listing of all local offices and mailing addresses,<br />
go to www.perkinelmer.com/lasoffices<br />
3
Global Expertise... Local Support<br />
Personalized Service from a PerkinElmer Office Near You<br />
PerkinElmer Consumables and Accessories Local Support<br />
NORTH AMERICA (cont)<br />
PANAMA<br />
Nes Scientific, S.A.<br />
Tel: 507-221-1426<br />
507-221-1455<br />
Fax: 507-221-96-27<br />
Email: nesscien@cwpanama.net<br />
PUERTO RICO<br />
Tel: 787-783-3067<br />
Fax: 787-793-7198<br />
OCEANIA<br />
AUSTRALIA<br />
Tel: 1-800 033 391<br />
Fax: 61-3-9212-8595<br />
NEW ZEALAND<br />
New Zealand Scientific Ltd<br />
Tel: 0800 776 767<br />
Fax: 0800 776 000<br />
SOUTH AMERICA<br />
ARGENTINA<br />
Tel: 5411-4554-4004<br />
Fax: 5411-4554-2807<br />
Email: alejandro.auffenfeld@<br />
perkinelmer.com.ar<br />
BOLIVIA<br />
Beco Internacional, LTDA.<br />
Tel: (59) 12-241-5446<br />
Fax: (59) 12-241-0639<br />
Email: beco@caoba.entelnet.bo<br />
BRAZIL<br />
Tel: 55-11-3868-6200<br />
Fax: 55-11-3872-0548<br />
Email: denise.schwartz@<br />
perkinelmer.com<br />
CHILE<br />
Tel: 56-2-655-1600<br />
Fax: 56-2-269-8070<br />
Email: hector.moncada@<br />
perkinelmer.com<br />
COLOMBIA<br />
Polco, S.A.<br />
Tel: (574) 230-57-67<br />
Fax: (574) 230-56-04<br />
Email: polco@epm.net.co<br />
ECUADOR<br />
Proinstra, S.A.<br />
Tel: (593)-22-263-937<br />
(593)-22-444-363<br />
Fax: (593) 22-922-267<br />
Email: proinstra@ecutel.net<br />
PARAGUAY<br />
Tel: 5411-4554-4004<br />
Fax: 5411-4554-2807<br />
Email: alejandro.auffenfeld@<br />
perkinelmer.com.ar<br />
PERU<br />
Científica Andina S.A.<br />
Tel: (5114) 444-9993<br />
(5114) 444-9983<br />
Fax: (5114) 444-9937<br />
Email: caballca@<br />
científica-andina.com.pe<br />
URUGUAY<br />
Coasin <strong>Instruments</strong><br />
Tel: 598-2-708-5866<br />
Fax: 598-2-709-0988<br />
Email: sirexur@adinet.com.uy<br />
VENEZUELA<br />
Corporación Científica<br />
Venezolana CA<br />
Tel: 58-212-7615-221<br />
58-212-7616-239<br />
Fax: 58-212-762-3050<br />
Email: ccvivanj@telcel.net.ve<br />
Order by Phone, Fax or E-mail<br />
Please contact your local PerkinElmer Customer Care<br />
Representative. See local office listings to the left and on<br />
the prior two pages.<br />
Order by Mail<br />
Visit us online at www.perkinelmer.com/lasoffices to obtain<br />
the correct address for mailing your company Purchase Order.<br />
You can also call or e-mail your local PerkinElmer Customer<br />
Care Representative. See local phone number and e-mail<br />
listings to the left and on the prior two pages.<br />
Order Online<br />
Place your order online at: www.perkinelmer.com/<strong>supplies</strong><br />
As of catalog press time, online ordering is available in the<br />
United States, Canada and the United Kingdom. Call your local<br />
office to find out if or when online ordering will be available<br />
in your local language or region. See local office listings to the<br />
left and on the prior two pages.<br />
Technical Support<br />
For technical assistance, please contact your local PerkinElmer<br />
Customer Care Representative. See local office listings to the<br />
left and on the prior two pages.<br />
Check with your local PerkinElmer Customer Care center for current pricing.<br />
PerkinElmer is a registered trademark of PerkinElmer, Inc. All other product and company names mentioned herein may be the trademarks or registered trademarks<br />
of their respective owners.<br />
PerkinElmer is not responsible for typographical or photographic errors that may appear in this catalog. We reserve the right to make adjustments or corrections due<br />
to changing market conditions, product discontinuations, or typographical or photographic errors in advertisements or product descriptions. Policies and item<br />
availability are subject to change without notice.<br />
For details on our terms and conditions, including warranties, please see pages 444-448 or visit our website at: www.perkinelmer.com/terms<br />
4<br />
www.perkinelmer.com/<strong>supplies</strong>
PerkinElmer, the undisputed leader in Atomic<br />
Absorption (AA), is the preferred choice for atomic<br />
spectroscopy solutions and services in thousands<br />
of laboratories globally, helping you advance<br />
research and development, control product<br />
quality and improve the environment.<br />
With a product line that features flame AA,<br />
high-performance graphite furnace, standardsetting<br />
WinLab32 software and a wide array<br />
of consumables and accessories, PerkinElmer<br />
AA’s are designed to meet your most demanding<br />
requirements for productivity, flexibility,<br />
ruggedness and performance.<br />
Atomic Absorption
Atomic Absorption<br />
QUICK-FIND INDEX Page #<br />
Autosampler Sample Cups 11<br />
Autosampler Sample Probes 9<br />
Burner Heads and Components 13<br />
Electrodeless Discharge Lamps 46<br />
Filters, Regulators, and<br />
Supplies 36<br />
Flow Injection Sampling<br />
Supplies 21<br />
HGA Graphite Tubes and<br />
Contact Cylinders 31<br />
Lumina Hollow Cathode Lamps 39<br />
Matrix Modifiers 67<br />
MHS System and Supplies 49<br />
Sample Preparation Supplies 50<br />
Nebulizers 16<br />
Standards 65<br />
THGA Graphite Tubes and<br />
Contact Cylinders 34<br />
WinLab32 Software for AA 70<br />
PerkinElmer offers a wide selection of superior quality products designed to work with<br />
your PerkinElmer instruments. Our precision-designed products deliver the peace of<br />
mind that comes from knowing that you’ll get the results you need.<br />
The Quick Find Index to the left will help you find products fast. For your convenience,<br />
products are alphabetized by category, sub-category, and family. There is also a more<br />
complete Alphabetical INDEX on page 429 and a Part Number INDEX on page 407.<br />
HGA Graphite Tubes and Supplies<br />
Lumina Hollow Cathode Lamps<br />
Standards<br />
PerkinElmer tubes are manufactured to the highest quality<br />
specifications. To ensure high quality and consistency, a<br />
specific grade of high-density base graphite material has<br />
been developed for PerkinElmer’s exclusive use. This base<br />
graphite material is used for the manufacturing of all<br />
PerkinElmer graphite tubes.<br />
Page 31<br />
Every genuine PerkinElmer Lumina lamp is designed<br />
for use with, and tested on, our spectrometers to<br />
assure compatibility and the highest performance.<br />
PerkinElmer offers a wide range of single-element and<br />
multi-element HCLs, which are ideal for determining most<br />
elements by atomic absorption spectroscopy.<br />
Page 39<br />
PerkinElmer offers a wide selection of atomic absorption<br />
calibration standards. Each solution is supplied with a<br />
comprehensive Certificate of Analysis that documents<br />
the quality. To ensure that your measurements are<br />
accurate, you can rely on our certificates to provide<br />
complete information.<br />
Page 65<br />
THGA Graphite Tubes and Supplies<br />
Our exclusive design ensures even heating over the entire<br />
length of the tube. PerkinElmer’s unique, transversely<br />
heated graphite tube includes an integrated platform. The<br />
exceptionally uniform temperature distribution obtained<br />
with transverse heating significantly reduces or eliminates<br />
condensation of the sample matrix components and<br />
“memory” effects, and improves the atomization<br />
efficiency for refractory elements.<br />
Page 34
The World Leader in<br />
Atomic Absorption<br />
OVER 40 YEARS OF EXPERTISE<br />
With over 40 years experience and a product line that<br />
includes flame AA systems, high-performance graphite<br />
furnace AA systems, flexible ICP-OES systems, and the<br />
most powerful ICP-MS systems, PerkinElmer is the<br />
undisputed leader in inorganic analysis. We have<br />
placed over 40,000 systems throughout the world,<br />
performing inorganic analyses every hour of every day.<br />
AAnalyst 200<br />
PerkinElmer is a world leader in chemical analysis. Our<br />
analytical instrument technologies serve the rapidly<br />
evolving pharmaceutical, chemical, environmental,<br />
forensics, and semiconductor industries, providing<br />
integrated solutions – from sample handling and<br />
analysis – to communication of test results.<br />
AAnalyst 200<br />
The AAnalyst 200 dramatically changes<br />
the way instruments are used and serviced,<br />
while maintaining all of the performance<br />
users have come to expect from PerkinElmer.<br />
The system incorporates innovations<br />
typically only offered on expensive researchgrade<br />
instrumentation. True double-beam<br />
Echelle optics combined with the power of<br />
a solid state detector delivers performance<br />
levels not typically available with flame<br />
AA. Plus, fully automated gas controls<br />
and integrated safety checks yield the<br />
safest flame AA system available today.<br />
Features:<br />
■ Intuitive touch screen is easy-to-use —<br />
no training required<br />
■ Snap-in, snap-out parts are easily<br />
replaced, so there is no downtime<br />
■ Rugged design can handle the toughest matrices<br />
■ PerkinElmer reliability and performance<br />
at an affordable price<br />
■ Features the first true double-beam<br />
Echelle optical system<br />
AAnalyst 400<br />
The AAnalyst 400 system is designed for<br />
the rigorous needs of today’s analytical<br />
laboratory, with proven WinLab32<br />
software providing all the flexibility<br />
and power you need in an easy-to-use,<br />
easy-to-learn package.<br />
AAnalyst 600<br />
The AAnalyst 600, a dedicated<br />
transversely heated graphite atomizer<br />
(THGA) system, offers the best in<br />
graphite furnace. With Zeeman<br />
background correction, the AAnalyst<br />
600 exceeds the requirements of today’s<br />
laboratories, whether analyzing difficult<br />
samples or for achieving the lowest<br />
detection levels. The high-lightthroughput<br />
optical system combined<br />
with a solid-state detector, provides<br />
the highest quality efficiency and<br />
signal-to-noise performance of any<br />
AA system on the market.<br />
AAnalyst 700<br />
The AAnalyst 700 Atomic Absorption<br />
Spectrometer offers productivity<br />
enhancing features for flame and furnace<br />
atomic absorption in a proven costeffective<br />
design. The fully integrated<br />
benchtop system includes flame and<br />
heated graphite furnace atomizers<br />
(HGA) with continuum source<br />
background correction.<br />
AAnalyst 800<br />
For laboratories that need the best in both<br />
flame and THGA furnace, the AAnalyst<br />
800 provides a fully integrated benchtop<br />
system with superior performance. With<br />
the AAnalyst 800, switching between<br />
flame and furnace is as simple as a click<br />
of the mouse and includes automatic<br />
alignment for optimum performance.<br />
The high-light-throughput optical system<br />
combined with a solid-state detector,<br />
provides the highest quality efficiency<br />
and signal-to-noise performance of any<br />
AA system on the market.<br />
7
Atomic Absorption Autosampler Supplies and Accessories<br />
Autosampler Supplies and Accessories<br />
Autosampler Flame/FIAS Trays and Vessels<br />
Accessories<br />
Description Part No. Each (€)<br />
AS-91 Plexiglass Cover B3000111 1103<br />
AS-93plus Dust Cover B3140770 1001<br />
Plexiglass cover for reduced contamination<br />
of samples from ambient particulates<br />
Adapter Plate for Gilson Racks for AS-93plus B3140647 48<br />
Required in order to use Gilson racks on an AS-93<br />
Rinsing Kits<br />
AS-93plus Rinsing Kit<br />
Includes: Part No. Each (€)<br />
Adapter M B0507919 15<br />
Connector B3140715 2<br />
Pump Tube - 1.14 mm i.d., (pkg. 6) B3140730 57<br />
Pump Tube - 2.79 mm i.d., (pkg. 6) B3140721 60<br />
PVC Rinse Liquid Feed Tube - 2 m B0048139 1<br />
Tygon ® Drain Tube - 2 m B0509650 16<br />
Rinsing Port B3140622 36<br />
AS-90plus Rinsing Kit<br />
Includes the rinse vessel (B300-0156) and the appropriate<br />
adapter and tubing. The vessel may not<br />
fit trays manufactured prior to 1996. Part No. Each (€)<br />
Sample Trays<br />
AS-90/90A/90plus<br />
Capacity Sample Vessel Size Part No. Each (€)<br />
Tray A-144 4.5 mL, 6 mL, 8 mL B3000133 338<br />
Tray B-98* 15 mL, 16 mL B3000132 113<br />
Tray C-36 50 mL B3000135 338<br />
Blank Tray B0501056 421<br />
*Polypropylene sample tray.<br />
AS-91<br />
Capacity Sample Vessel Size Part No. Each (€)<br />
Tray E-218 4.5 mL, 6 mL, 8 mL B0509554 440<br />
Tray F-152 15 mL, 16 mL B0509555 440<br />
Tray G-55 50 mL B0508520 440<br />
Trays A, C, E, F, and G are powder-coated, corrosion-resistant aluminum.<br />
AS-93plus<br />
Capacity Sample Vessel Size Part No. Each (€)<br />
9/29 50 mL/15 mL B3001647 26<br />
30 50 mL B3140621 26<br />
60 15 mL, 16 mL B3140618 26<br />
90 4.5 mL, 6 mL, 8 mL B3140617 26<br />
AS-93plus sample trays are polypropylene.<br />
Part No.<br />
Each (€)<br />
B3140236 292<br />
B3000166 185<br />
Sample Vessels<br />
AS-90/90A/<br />
90plus/91/93plus<br />
Translucent polypropylene<br />
vessels with excellent<br />
chemical resistance.<br />
Sample Vessel Volume Quantity Part No. Each (€)<br />
4.5 mL 1000 N9301204 75<br />
6 mL** 500 B0193235 325<br />
8 mL 1000 B0508901 453<br />
15 mL** 500 B0193233 325<br />
16 mL 1000 N9301205 93<br />
50 mL** 500 B0193234 257<br />
** Includes screw caps.<br />
Caps, for 8 mL Vessels<br />
Package of 1000.<br />
AS-90/91 Wash Vessel, Polypropylene<br />
Includes cover (250 mL).<br />
Tubes and Beakers<br />
AS-50/51<br />
AS-93plus<br />
Part No.<br />
Each (€)<br />
B0508902 153<br />
Part No.<br />
Each (€)<br />
B0501258 36<br />
Description Part No. Each (€)<br />
Polystyrene Test Tubes 00471441 32<br />
Cone-shaped bottoms permit use of small<br />
samples. Clear, affordable polystyrene is<br />
recommended for use with most aqueous<br />
solutions (125 test tubes)<br />
Berzelius Tall-form Beaker 00471440 6<br />
Pyrex ® beaker (400 mL) used as a wash<br />
vessel for the autosampler<br />
8
Sampling Probe Assemblies,<br />
AS-90/90A/90plus/91/93plus<br />
Autosamplers automate standard and sample introduction<br />
for instrument calibration and sample analysis via software<br />
commands, extending the spectrometer’s capabilities to<br />
those of a fully-automated analytical workstation.<br />
Stainless Steel Probe<br />
Part No. B3000152<br />
Stainless Steel<br />
Description Part No. Each (€)<br />
Sampling Probe Assembly, B3000159 198<br />
0.6 mm i.d.<br />
Stainless steel sampling probe and screw fitting, B3000152,<br />
and flame capillary tubing assembly, B3000157.<br />
Sampling Probe Assembly, B3000160 198<br />
0.6 mm i.d.<br />
Stainless steel sampling probe and screw fitting, B3000152<br />
and FIAS TM capillary tubing assembly B3000158.<br />
Standard Sampling Probe Assembly, B3000161 198<br />
1.0 mm i.d.<br />
Stainless steel sampling probe and screw fitting, probe B3000152,<br />
and FIAS capillary tubing assembly B0191060.<br />
Corrosion-Resistant<br />
Description Part No. Each (€)<br />
Flame Sampling Probe Assembly, B3001770 217<br />
0.6 mm i.d.*<br />
Corrosion-resistant probe, suitable for inorganic acids and most organic<br />
solvents, except NMP. Includes sampling probe with FEP tube and screw<br />
fitting (B3000055) and capillary tubing assembly (B3000157).<br />
Sampling Probe Assembly, B3001771 198<br />
0.6 mm i.d.*<br />
Corrosion-resistant probe, suitable for inorganic acids and most organic<br />
solvents, except NMP. Includes sampling probe with FEP tube and screw<br />
fitting (B3000055) and capillary tubing assembly (B3000158).<br />
Standard Sampling Probe Assembly, B3001772 217<br />
1.0 mm i.d.*<br />
Corrosion-resistant probe, suitable for inorganic acids and most organic<br />
solvents, except NMP. Includes sampling probe with FEP tube and screw<br />
fitting (B3001769), and capillary tubing assembly (B0191060).<br />
* Probe cannot be used with AS-90s, which have the older sampling probe holder.<br />
Autosampler Supplies and Accessories<br />
Autosampler Flame/FIAS Probes<br />
Sampling Probe Assembly Components,<br />
AS-90/90A/90plus/91/93plus<br />
Corrosion-Resistant Sampling Probes<br />
with Screw Fitting<br />
Suitable for inorganic acids and most organic solvents,<br />
except NMP. Requires, but does not include, one of the<br />
capillary tubing assemblies described below.<br />
Description ID Part No. Each (€)<br />
Corrosion-Resistant Sampling Probe 0.6 mm B3000055 134<br />
Corrosion-Resistant Sampling Probe 1.0 mm B3001769 97<br />
Stainless Steel Sampling Probe w/Screw Fitting<br />
Requires, but does not include,<br />
one of the capillary tubing<br />
assemblies described below.<br />
Capillary Tubing Assembly<br />
Depending on the autosampler application, the sampling<br />
probe can be equipped with any of three types of capillary<br />
tubing assembly, which have different tubing diameters and<br />
either one or two screw fittings.<br />
Description Part No. Each (€)<br />
1 m length, 0.6 mm i.d., one fitting B3000157 40<br />
1 m length, 0.6 mm i.d., two fittings B3000158 18<br />
1 m length, 1.0 mm i.d., two fittings B0191060 19<br />
Used Oil Autosampler Probe<br />
Autosampler probe for the AS-90plus and the AS-93plus<br />
Autosamplers. The probe includes a<br />
particulate filter on the tip to remove<br />
fibers. For use in used oil analysis.<br />
Part No.<br />
N0771529<br />
Each (€)<br />
249<br />
Sampling Probes, AS-50/51<br />
Stainless Steel Sampling Probe<br />
For use with both aqueous<br />
and organic samples. (pkg. 5)<br />
Platinum/Rhodium Sampling Probe**<br />
Accessory probe recommended for use<br />
when samples corrosive to stainless<br />
steel are being analyzed. (pkg. 1)<br />
Quartz Sampling Probes***<br />
Probe recommended for use when<br />
samples corrosive to stainless steel<br />
are being analyzed. (pkg. 5)<br />
Sampling Probe Cleaning Wire (1 M)<br />
For AS-90/91/90plus/93plus probe.<br />
Part No.<br />
Part No.<br />
Each (€)<br />
B3000152 143<br />
Part No.<br />
** Not recommended for use with samples containing aqua regia.<br />
*** Cannot be used with samples containing hydrofluoric acid or other<br />
reagents corrosive to quartz.<br />
Sampling Probe Supplies<br />
Each (€)<br />
00471422 18<br />
Part No.<br />
Each (€)<br />
00471420 363<br />
Part No.<br />
Each (€)<br />
N0580540 112<br />
Each (€)<br />
B0505962 42<br />
Autosampler Supplies and Accessories Atomic Absorption<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
9
Atomic Absorption Autosampler Supplies and Accessories<br />
Autosampler Supplies and Accessories<br />
Dilution System Supplies<br />
AutoPrep 50<br />
1<br />
1<br />
2<br />
AutoPrep 50 Tubing<br />
4 4<br />
5<br />
3<br />
AutoPrep 50<br />
The AutoPrep TM 50 provides automatic, intelligent on-line<br />
dilution capabilities for flame Atomic Absorption.<br />
Key features of the AutoPrep 50 include:<br />
■ Fully automatic sample introduction<br />
■ Automatic intelligent selection of dilution range<br />
■ Automatic preparation of multiple standards from<br />
a single stock solution<br />
■ Integrated software control<br />
Diluter Parts<br />
Description Part No. Each (€)<br />
Pump Assembly, 5 mL B3141052 103<br />
(includes pump head and piston assembly)<br />
Sample Holding Coil, 5 mL B3140123 117<br />
Valve 1 (V1, 3-port with red mark) B3002072 40<br />
Valve 2 (V2, 3-port with yellow mark) B3002094 40<br />
Valve 3 (V3, 3-port with black mark) B3002076 41<br />
Valve 4 (V4, 3-port with black mark) B3002091 40<br />
T-union (T1, black mark) B3002097 45<br />
Thumbscrew for Valves and T-union B3140211 26<br />
Thumbscrew for Sample Holding Coil B3140210 26<br />
Sampling Probe for AS 90/91, complete, B3140244 124<br />
connects AS 90/91 to AutoPrep 50 Valve 3<br />
Nuts and Ferrules<br />
Description Part No. Each (€)<br />
Front Ferrule for 2.4 mm o.d. tubing (B0017998) B3001333 11<br />
Back Ferrule for 2.4 mm o.d. tubing (B0017998) B3001334 10<br />
Nut for 2.4 mm o.d. tubing (B0017998) B3001335 7<br />
Front Ferrule for 1.6 mm o.d. tubing (B0029792) 09920123 19<br />
Back Ferrule for 1.6 mm o.d. tubing (B0029792) 09920124 16<br />
Nut for 1.6 mm o.d. tubing (B0029792) B0080333 7<br />
Tubing<br />
1<br />
2<br />
3<br />
4<br />
5<br />
Description Part No. Each (€)<br />
Diluent and Waste Tube B3140226 40<br />
(connects to V1 or V4), complete,<br />
1.7 mm i.d., 2.4 mm o.d., 1.2 m long<br />
Diluent Feed Tube (connects to V2), B3140227 34<br />
complete 1.0 mm i.d.,<br />
1.6 mm o.d., 0.7 m long<br />
PTFE Tubing B0509652 3<br />
(connects the T-union with the<br />
nebulizer) 0.56 mm i.d., 1.67 mm o.d.<br />
PTFE Tubing, used to interconnect B0029792 2<br />
valves, 1.0 mm i.d., 1.6 mm o.d.<br />
PTFE Tubing, used to connect the<br />
sample pump to the valve (V1), B0017998 3<br />
1.7 mm i.d., 2.4 mm o.d.<br />
Tubing Cutter B3000019 43<br />
10
Autosampler Sample Cups<br />
■<br />
■<br />
Autosampler Supplies and Accessories<br />
Graphite Furnace Autosampler Supplies for the AS-40/60/70/71/72/800<br />
Heavy-duty construction prevents cracking or tipping<br />
Conical design allows for use of entire sample<br />
Your choice of materials:<br />
Polystyrene – Clear, recommended for use with most<br />
aqueous solutions.<br />
Polyethylene – Translucent, low density, recommended<br />
for use with most aqueous and organic solutions.<br />
Teflon ® – Recommended for use with most concentrated<br />
acids including HF and for analyses where the lowest<br />
detection levels are required.<br />
Polypropylene – Translucent. No known solvent at<br />
room temperature.<br />
Graphite Furnace Autosampler Cups<br />
Volume Composition Qty. Part No. Each (€)<br />
7 mL**** Polypropylene 100 B3001567 33<br />
3.5 mL** Polystyrene 100 B0129303 34<br />
2.5 mL** Polypropylene 1000 B3001566 47<br />
2 mL* Polyethylene 1000 B0087056 53<br />
2 mL* Polystyrene 1000 B0119079 82<br />
2 mL* Teflon 30 B0087600 242<br />
1.2 mL*** Polypropylene 2000 B0510397 61<br />
* For use with AS-40/60/70/71/72/800 *** For use with AS-71/72/800<br />
** For use with AS-60/70/71/72/800 **** For use with AS-800<br />
Pliers<br />
For 1.2 mL sample cups.<br />
148-Position Tray, Polypropylene<br />
(For Model AS-800)<br />
Part No. B3001506<br />
Part No.<br />
Each (€)<br />
B0510398 11<br />
88-Position Tray, Polypropylene<br />
(For Model AS-800)<br />
Part No. B3001507<br />
Autosampler Trays<br />
Description Part No. Each (€)<br />
For Model AS-40<br />
Sample Tray B0101045 459<br />
For Models AS-60/70<br />
Sample Tray* B0510417 66<br />
For Models AS-71/72<br />
40-Position Tray, Plastic B0510417 66<br />
35 sample locations for 2 or 3.5 mL sample cups*<br />
80-Position Tray, Plastic B0510404 41<br />
75 sample locations for 1.1 mL sample cups*<br />
Sample Tray Cover B3001330 23<br />
For Model AS-800<br />
88-Position Tray, Polypropylene B3001507 21<br />
80 sample locations for 2, 2.5, or 3.5 mL sample<br />
cups. Each sample tray also has eight positions<br />
for 7 mL reagent containers.<br />
148-Position Tray, Polypropylene B3001506 21<br />
132 sample locations for 1.1 mL sample cups<br />
and eight locations for 2.5 or 3.5 mL sample<br />
cups. Each sample tray also has eight positions<br />
for 7 mL reagent containers.<br />
AS-800 Supplies<br />
Arm B3002046 8<br />
Sampling Arm Collar B3001465 14<br />
Set Screw for Collar B0055900 1<br />
Sample Tray Cover B3001505 17<br />
* Each sample tray has five positions for 30 mL<br />
cloverleaf-shaped reagent containers<br />
Check Valves<br />
Description Part No. Each (€)<br />
Inlet (complete) B3002007 267<br />
Includes ferrules and connector<br />
Outlet (complete) B3002006 267<br />
Includes ferrules and connector<br />
Solvent-Resistant Check Valves<br />
Description Part No. Each (€)<br />
Inlet B0105973 437<br />
Outlet B0105974 359<br />
Autosampler Supplies and Accessories Atomic Absorption<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
11
Autosampler Supplies and Accessories<br />
Atomic Absorption Autosampler Supplies and Accessories<br />
Graphite Furnace Autosampler Supplies for the AS-40/60/70/71/72/800<br />
AS-800 Autosampler<br />
Ferrule Kits<br />
Rinse Tubing Ferrules<br />
Description Size Part No. Each (€)<br />
Front Ferrule 2.45 mm i.d. B3001333 11<br />
Rear Ferrule 2.45 mm i.d. B3001334 10<br />
Sample Tubing Ferrule Kit (1.6 mm i.d.)<br />
Used with B0129258 and<br />
B0101161 sampling capillaries.<br />
Contains 5 front and 5 rear ferrules.<br />
Tubing Only (PTFE)*<br />
Description Size Part No. Each (€)<br />
Rinse Tubing 1.6 mm o.d. B0029792 2<br />
Sample Tubing 2.45 mm o.d. B0017998 3<br />
* Order per meter.<br />
Part No.<br />
Each (€)<br />
B0086142 68<br />
Sampling Capillary<br />
(For Models AS-60/70/71/72/800)<br />
Part No. B0129258<br />
Reagent Containers<br />
For Models AS-40/60/70/71/72<br />
Round Reagent Containers<br />
For blank solutions, reagent solutions, or matrix modifiers.<br />
Volume Composition Part No. Each (€)<br />
20 mL PTFE* B0103037 40<br />
20 mL Polypropylene** B0101164 10<br />
25 mL Polystyrene*** B0102332 5<br />
* Solvent-resistant (AS-40 only)<br />
** Suitable for organic solutions<br />
*** Not suitable for organic solutions<br />
For Models AS-60/70/71/72<br />
Cloverleaf-Shaped<br />
Reagent Containers<br />
30 mL polypropylene.<br />
■ Resists most acid solutions<br />
■ Provides more reagent volume, yet<br />
occupies only one sample space<br />
■ Allows you to insert up to five<br />
different reagent solutions<br />
or matrix modifiers for one run<br />
Rinse Solution Bottle (2 L)<br />
Waste Solution Bottle (2 L)<br />
Sampling Capillaries<br />
■<br />
■<br />
■<br />
Solvent- and acid-resistant sampling components<br />
PTFE pipette tips and capillaries for reduced contamination<br />
Easy replacement<br />
Part No.<br />
Each (€)<br />
B0132799 34<br />
Part No.<br />
Each (€)<br />
B0104281 110<br />
Part No.<br />
Each (€)<br />
B0104987 41<br />
Description Part No. Each (€)<br />
For Model AS-40<br />
Sampling Capillary B0101161 242<br />
For Models AS-60/70/71/72/800<br />
Sampling Capillary B0129258 242<br />
12
Burner System Components<br />
AAnalyst 100/200/300/400/700/800<br />
Burner Heads<br />
AAnalyst Burner Heads cannot be used with other PerkinElmer<br />
AA Spectrometers.<br />
A Single-Slot Nitrous Oxide-Acetylene<br />
The 5 cm nitrous oxide burner head is required<br />
for nitrous oxide-acetylene operation. This<br />
burner head can also be<br />
used with air-acetylene<br />
or rotated to provide<br />
reduced sensitivity.<br />
Part No.<br />
N0400100<br />
Each (€)<br />
982<br />
A<br />
A<br />
A<br />
Single-Slot Air-Acetylene<br />
The 10 cm burner head is designed to be used<br />
with the air-acetylene flame. Because of its<br />
long burner path length, it provides the best<br />
sensitivity for airacetylene<br />
elements.<br />
Part No. Each (€)<br />
N0400102 982<br />
Three-Slot Air-Acetylene<br />
The three-slot burner head (10 cm) is designed<br />
to be used when analyzing samples with high<br />
concentrations of dissolved solids. The threeslot<br />
burner head is not<br />
compatible with some<br />
older gas control systems.<br />
Part No.<br />
N0400103<br />
Each (€)<br />
982<br />
Single-Slot Air-Acetylene<br />
A 5 cm air-acetylene burner head (5 cm) is<br />
available for applications in which reduced<br />
sensitivity is required. It can be rotated to<br />
provide further sensitivity<br />
reduction, and it has a wide<br />
slot to prevent clogging.<br />
Part No.<br />
N0400101<br />
Each (€)<br />
982<br />
Burner Head Cleaning Tool<br />
6<br />
G1<br />
7<br />
2<br />
2<br />
5<br />
3<br />
1<br />
4<br />
3<br />
D<br />
G2<br />
Part No.<br />
Each (€)<br />
03031573 3<br />
F<br />
E<br />
A<br />
C<br />
B<br />
Burner System Components<br />
B<br />
C<br />
D<br />
E<br />
F<br />
G1<br />
G2<br />
Components Part No. Each (€)<br />
Viton Burner Head O-Ring 09902219 2<br />
Burner Mixing Chamber Assembly 00570948 402<br />
Clamping Ring N0401171 26<br />
Flow Spoiler 00572561 20<br />
End Cap O-Ring<br />
Aqueous (Viton) 09902147 2<br />
Organics (Corkprene) 00472014 3<br />
Aqueous and Organics (KALREZ ® )* 09921044 266<br />
End Cap Assembly N0370392 287<br />
Used with the following nebulizers:<br />
03030352, 03030404, 03030299.<br />
End Cap Assembly 00570984 440<br />
Used with the following nebulizers:<br />
B0505480, B0505590, N0370394,<br />
N0370393, N3150188.<br />
* Recommended for use when determination of organic and acid based<br />
solutions required<br />
Impact Bead and Retainer Assembly<br />
This can only be used with the End Cap Assembly<br />
(Part No. 00570984).<br />
Description Part No. Each<br />
1<br />
2<br />
3<br />
4<br />
5<br />
6<br />
7<br />
Seal Plug 00572624 38<br />
Large Impact Bead O-Ring 09902240 3<br />
O-Ring (1/8 in.) 09902236 2<br />
Impact Bead 00572615 70<br />
Impact Retainer 00572695 30<br />
Split Lockwasher 09911286 1<br />
Binding Head Screw 09910148 1<br />
Burner Gasket Kit 00470988 71<br />
Includes: Kit Qty. Part No. Each (€)<br />
Corkprene End Cap O-Ring 5 00472014 3<br />
Viton End Cap O-Ring 3 09902147 2<br />
Viton Burner Head O-Ring 1 09902219 2<br />
Small Impact Bead O-Ring 3 09902236 2<br />
Large Impact Bead O-Ring 3 09902240 3<br />
Magnet Assembly for AAnalyst N2010381 32<br />
700/800<br />
Magnet Assembly for AAnalyst N1010215 32<br />
100/200/300/400<br />
Drain Components<br />
Components Part No. Each (€)<br />
Drain Tubing, AAnalyst 100/200/300/400/700/800 02507987 22<br />
AAnalyst 700/800 Drain Assembly N2011074 1346<br />
AAnalyst 100/300 Drain Assembly N0400058 779<br />
Drain Bottle 09904991 112<br />
(€)<br />
Burner System Components Atomic Absorption<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
13
Burner System Components<br />
Models 2280, 2380, 3030(B), 3100, 3110, 3300, 4000*, 5000*, and 5100 PC<br />
Burner Heads<br />
Burner Gasket Kit<br />
Part No. Each (€)<br />
00470988 71<br />
Atomic Absorption Burner System Components<br />
E1<br />
E2<br />
E3<br />
E1<br />
Single-slot Burner Head 00400266 893<br />
The 10 cm burner head is designed to be used with the<br />
air-acetylene flame. Because of its long burner path length,<br />
it provides the best sensitivity for air-acetylene elements.<br />
Nitrous Oxide Burner Head 00400277 867<br />
The 5 cm nitrous oxide burner head is required for nitrous<br />
oxide-acetylene operation. This burner head can also be used<br />
with air-acetylene or rotated to provide reduced sensitivity.<br />
Three-slot Burner Head 00400289 867<br />
The three-slot burner head is designed to be used when<br />
analyzing samples with high concentrations of dissolved solids.<br />
The three-slot burner head is not compatible with<br />
some older gas control systems.<br />
Burner Head Cleaning Tool 03031573 3<br />
Burner System Components<br />
1<br />
2<br />
3<br />
4<br />
5<br />
A<br />
B<br />
C<br />
Components Part No. Each (€)<br />
Viton Burner Head O-Ring 09902219 2<br />
Aqueous Viton End Cap O-Ring 09902147 2<br />
Organic (Corkprene) End Cap O-Ring 00472014 3<br />
Aqueous/Organic (Kalrez) 09921044 266<br />
End Cap O-Ring<br />
Clamping Ring 00572616 78<br />
Stainless Steel Locking Ring 00572737 107<br />
Use N0371071 for Models 3300,<br />
3110, and 3100<br />
End Cap Assembly** 00570984 440<br />
Flow Spoiler 00572561 20<br />
Burner Mixing Chamber 00570948 402<br />
Impact Bead Assembly<br />
D<br />
6<br />
7<br />
8<br />
9<br />
10<br />
11<br />
Impact Bead 00572615 70<br />
Seal Plug 00572624 38<br />
O-Ring (1/4 in./6 mm i.d.) 09902240 3<br />
O-Ring (1/8 in./3 mm i.d.) 09902236 2<br />
Impact Retainer 00572695 30<br />
Split Lockwasher 09911286 1<br />
Binding Head Screw 09910148 1<br />
* For use on models 4000 and 5000 shipped after May 1980<br />
** A different end cap assembly, N0370392, is required for use<br />
with the high-sensitivity nebulizer<br />
E3<br />
E2<br />
Includes: Kit Qty. Part No. Each (€)<br />
Corkprene End Cap O-Ring 5 00472014 3<br />
Viton End Cap O-Ring 3 09902147 2<br />
Viton Burner Head O-Ring 1 09902219 2<br />
Small Impact Bead O-Ring 3 09902236 2<br />
Large Impact Bead O-Ring 3 09902240 3<br />
Burner Drain Assembly 00470391 236<br />
Includes Drain Loop and Interlock only, for Models 2280, 2380, 3030(B),<br />
4000, 5000, and 5100 PC.<br />
Burner Drain Assembly N0370149 252<br />
Includes Drain Loop and interlock only, for Models 3100, 3110, and 3300.<br />
Cable and Pin Assemblies<br />
Components Part No. Each (€)<br />
For Air-Acetylene Burner Head (short pin) 00400276 56<br />
For Nitrous Oxide Burner Head (long pin) 00400275 56<br />
Hold Down Cable 03030130 10<br />
A<br />
11<br />
2<br />
10<br />
7<br />
3<br />
4<br />
B<br />
9<br />
7<br />
8<br />
6<br />
1<br />
8<br />
C<br />
D<br />
5<br />
E<br />
14
Burner System Components<br />
Models 1100(B), 2100, and 4100<br />
Burner Heads<br />
E<br />
E<br />
Single-Slot Burner Head B0162668 918<br />
The 10 cm burner head is designed to be used with<br />
the air-acetylene flame. Because of its long burner<br />
path length, it provides the best sensitivity for<br />
air-acetylene elements.<br />
Nitrous Oxide Burner Head B0162669 1530<br />
The 5 cm nitrous oxide burner head is required for<br />
nitrous oxide-acetylene operation. This burner head<br />
can also be used with air-acetylene or rotated to<br />
provide reduced sensitivity.<br />
Burner Head Cleaning Tool 03031573 3<br />
Burner System Components<br />
Components Part No. Each (€)<br />
91 Viton Burner Head O-Ring 09902219 2<br />
10 2 Aqueous End Cap O-Ring B0158690 11<br />
11 3 Organic (Corkprene) End Cap O-Ring B0158598 7<br />
4 Hold Down Wire (Pkg. 1, not shown) B0160697 47<br />
B5 Flow Spoiler 00572561 20<br />
C6 Burner Mixing Chamber B0153250 523<br />
F7 Impact Bead Assembly B0151579 580<br />
G8 Impact Bead, Ceramic B0158616 79<br />
A H End Cap and Drain Interlock Assembly B0151573 561<br />
BI<br />
Insert B0157117 38<br />
JC Clamping Ring B0162671 226<br />
Aqueous Burner Gasket Kit Assembly B0155546 210<br />
For Aqueous Solutions.<br />
Includes: Kit Qty. Part No. Each (€)<br />
Viton Burner Head O-Ring 1 09902219 2<br />
Aqueous End Cap O-Ring 1 B0158690 11<br />
Corkprene End Cap O-Ring 5 B0158598 7<br />
Plug O-Ring (Aqueous) 2 B0151697 1<br />
O-Ring between End Cap and Drain Vessel 1 B0129926 1<br />
Organic Burner Gasket Kit Assembly B0173404 848<br />
For Organic Solutions. Includes Gaskets, O-Rings, and Seals for the<br />
Models 4100, 2100, or 1100(B). Delivered in convenient storage box.<br />
Includes: Kit Qty. Part No. Each (€)<br />
Plug O-Ring 3 B0174378 56<br />
O-Ring and Drain 1 B0174379 50<br />
End Cap Gasket 1 B0174380 45<br />
O-Ring and Bead Holder Assembly 1 B0181842 57<br />
O-Ring on Nebulizer Venturi 1 B0190001 45<br />
O-Ring, High-Sensitivity Nebulizer 1 B0190672 29<br />
Drain Tube (2 m) 1 B0102949 12<br />
H<br />
10<br />
11<br />
J<br />
B<br />
Burner Head Cleaning Tool<br />
Part No. 03031573<br />
F<br />
9<br />
I<br />
C<br />
E<br />
G<br />
Burner System Components Atomic Absorption<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
15
Burner System Components<br />
Nebulizers<br />
Atomic Absorption Burner System Components<br />
PerkinElmer nebulizers are available in a variety of<br />
configurations to meet all of your analytical needs.<br />
The nebulizer is one of the most important components in<br />
a flame AA spectrometer. Sample solutions, with differing<br />
physical properties, must be converted into an aerosol of<br />
small, similarly sized droplets. This places great demands<br />
on the design of the nebulizer.<br />
All PerkinElmer nebulizer assemblies are adjustable for<br />
optimized performance and include easily interchanged<br />
capillary assemblies for simple, reduced-cost maintenance.<br />
PerkinElmer nebulizers are manufactured to exacting tolerances<br />
to provide maximum sensitivity. Universal, or “standard,”<br />
nebulizers are less expensive than the corresponding highsensitivity<br />
nebulizers and provide a lower level of sensitivity.<br />
The universal, or “standard,” nebulizers typically provide<br />
better precision and reduced “carryover” interference when<br />
used with solutions that contain high dissolved solids and<br />
content of higher analyte concentrations.<br />
Corrosion-Resistant Nebulizer<br />
For all solutions containing hydrofluoric acid or aqua regia<br />
For all solutions containing high concentrations of<br />
dissolved solids<br />
All internal components in contact with solutions are<br />
constructed of plastic to resist corrosion from<br />
concentrated acids<br />
Reduced performance compared with stainless steel or<br />
platinum/rhodium nebulizers<br />
GemTip Nebulizer<br />
Corrosion-resistant and can be used to aspirate almost<br />
all solutions, even those solutions containing a high<br />
percentage of acids<br />
Designed to obtain optimum sensitivity, detection limits,<br />
and precision with flame atomic absorption for both<br />
air-acetylene and nitrous oxide-acetylene flames<br />
High-Sensitivity Nebulizers<br />
Provide maximum sensitivity, precision, and freedom<br />
from analytical interferences<br />
The high-sensitivity nebulizer with platinum/iridium<br />
capillary is for most solutions, but not for precious metal<br />
samples containing aqua regia<br />
High-sensitivity nebulizer with tantalum capillary used<br />
for solutions containing aqua regia<br />
Platinum Alloy Nebulizer<br />
Recommended for most concentrated acids<br />
containing >5% acid<br />
Includes a platinum alloy needle assembly and a<br />
tantalum venturi<br />
Provides maximum chemical resistance<br />
Not suitable for use with aqua regia or hydrofluoric acid<br />
Stainless Steel Nebulizer<br />
For most solutions containing
Burner System Components<br />
Nebulizer Assemblies and Components Quick Reference<br />
Plastic Body Nebulizers<br />
For AAnalyst 100/300/700/<br />
For AAnalyst 800, Models 3100/3110/3300/<br />
200/400 5000/5100 PC and Earlier AAs 1100(B)/2100/4100<br />
GemTip Nebulizer (see page 18) Part No. Each (€) Part No. Each (€) Part No. Each (€)<br />
D<br />
F<br />
E<br />
A<br />
D<br />
F<br />
C<br />
E<br />
Stainless Steel Body Nebulizers<br />
A<br />
B<br />
A<br />
B<br />
A<br />
GemTip Nebulizer Assembly 3 N0370394 663<br />
High-Sensitivity GemTip Nebulizer Assembly 3 N0370393 1167<br />
High-Sensitivity Nebulizer with Pt/Ir Capillary 4 (see page 19) Part No. Each (€) Part No. Each (€) Part No. Each (€)<br />
C<br />
Nebulizer Assembly 3 N3150188 423 B0505480 1518 B0501029 1518<br />
Nebulizer End Cap Nut B0501026 7 B0501026 7<br />
Nebulizer Spacer 09902015 6<br />
Nebulizer Body B0506666 166 B0506668 166<br />
Impact Bead B0505086 63 B0505086 63 B0505086 63<br />
Locking Ring B0501025 7 B0501025 7<br />
Capillary Assembly B0501022 242 B0501022 242<br />
High-Sensitivity Nebulizer with Tantalum Capillary 4 (see page 19) Part No. Each (€) Part No. Each (€) Part No. Each (€)<br />
A<br />
Nebulizer Assembly 3 B0505590 1734 B0505589 1734<br />
Nebulizer End Cap Nut B0501026 7 B0501026 7<br />
Nebulizer Body B0506666 166 B0506668 166<br />
Capillary Assembly B0505588 599 B0505588 599<br />
Impact Bead B0505086 63 B0505086 63<br />
Locking Ring B0501025 7 B0501025 7<br />
Corrosion-Resistant Nebulizer 1 Part No. Each (€) Part No. Each (€) Part No. Each (€)<br />
Nebulizer Assembly 03030404 752 N3110110 1167<br />
Capillary Assembly 03030402 242 03030402 242<br />
Capillary Assembly for AS-51 or AS-50 00570957 236 00570957 236<br />
O-Ring Kit N9300065 84 N9300066 84<br />
Venturi 03031920 134 03031920 134<br />
Platinum Alloy Nebulizer 1 Part No. Each (€) Part No. Each (€) Part No. Each (€)<br />
Nebulizer Assembly 03030299 1059 N3110111 1518<br />
Capillary Assembly 2 03030433 395 03030433 395<br />
O-Ring Kit N9300065 84 N9300066 84<br />
Venturi 03033124 536 N3111158 854<br />
Stainless Steel Nebulizer 1 (see page 20) Part No. Each (€) Part No. Each (€) Part No. Each (€)<br />
Nebulizer Assembly 03030352 606 N3110109 1001<br />
Capillary Assembly 03030354 134 03030354 134<br />
O-Ring Kit N9300065 84 N9300066 84<br />
B Venturi 03031810 134 B0166503 111<br />
1 - Stainless steel body 2 - Etched with a “P” for identification 3 - Requires End Cap Assembly (N0370392) 4 - Inert plastic body with red adjusting ring<br />
Burner System Components Atomic Absorption<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
17
Burner System Components<br />
Nebulizers and Components<br />
Accessories<br />
Atomic Absorption Burner System Components<br />
Nebulizer Capillary Tubing<br />
10 ft. (3 m) length of 0.58 mm i.d.<br />
polyethylene tubing, for use with<br />
the stainless steel, platinum/<br />
rhodium and GemTip TM Nebulizers.<br />
Not suitable for corrosion-resistant<br />
nebulizers where capillary tubing is<br />
part of capillary<br />
Part No. Each (€)<br />
assembly. Not<br />
compatible with N3150188 Nebulizer. 09908265 29<br />
Nebulizer Cleaning Wires<br />
GemTip Nebulizers<br />
GemTip Nebulizer<br />
1<br />
2<br />
3<br />
4<br />
11<br />
5<br />
10<br />
Made of soft alloy copper,<br />
these cleaning wires are<br />
specially deburred to prevent<br />
scratching of the orifices and<br />
internal components of the<br />
nebulizers while cleaning.<br />
Use only PerkinElmer<br />
cleaning wires to clean<br />
nebulizers. (pkg. 5)<br />
6<br />
9 8<br />
13<br />
Part No.<br />
12<br />
7<br />
Each (€)<br />
03030135 17<br />
For AAnalyst TM 100/300/700/800*<br />
Description Part No. Each (€)<br />
Universal GemTip Assembly Complete** N0370394 663<br />
High-Sensitivity GemTip Assembly Complete** N0370393 1167<br />
1<br />
2<br />
3<br />
4<br />
5<br />
6<br />
7<br />
8<br />
9<br />
10<br />
11<br />
12<br />
13<br />
Nebulizer Grease<br />
A small quantity of Apiezon ® -L<br />
grease helps to lubricate the<br />
O-Ring seals for reassembly and<br />
ensures leak-proof operation. A<br />
tube of grease is supplied with<br />
each complete nebulizer assembly.<br />
However, you should order the tube if you purchase separate<br />
capillary and venturi sections.<br />
Part No. Each (€)<br />
03030405 9<br />
Component Part No. Each (€)<br />
Capillary Tubing 09908265 29<br />
Adjustment Nut N0371492 25<br />
Gland Nut N0371505 13<br />
Teflon Tubing 09985708 7<br />
Capillary Holding Assembly*** N0371520 223<br />
Capillary Holding Assembly**** N0371522 223<br />
O-Ring 09926083 10<br />
Impact Bead***** B0505086 63<br />
O-Ring 09902015 6<br />
O-Ring****** B0174378 56<br />
Body Assembly*** N0370398 402<br />
Body Assembly**** N0370399 427<br />
Locking Nut N0371493 12<br />
Spring 09902473 1<br />
Connector Nut N0371485 13<br />
Magnet Holder Assembly N1010215 32<br />
* Shipped before Fall 1999<br />
** Requires End Cap Assembly (N0370392)<br />
*** For Universal GemTip Nebulizers<br />
**** For high-sensitivity GemTip Nebulizers<br />
***** Included with high-sensitivity GemTip Nebulizer only<br />
****** Organic Resistant<br />
18
Burner System Components<br />
Nebulizers and Components<br />
High-Sensitivity Nebulizers*<br />
For Models AAnalyst 100/300/700/800/<br />
1100(B)/2100/3100/3110/4100/5100 PC<br />
Description Part No. Each (€)<br />
High-Sensitivity Nebulizer Assembly with<br />
Pt/Ir Capillary B0505480 1518<br />
High-Sensitivity Nebulizer Assembly with<br />
Tantalum Capillary B0505590 1734<br />
Components Part No. Each (€)<br />
21 O-Ring B0174378 56<br />
22 Spring B0165332 3<br />
23 O-Ring B0190672 29<br />
A / C / D / E / F See chart on page 17<br />
* Requires End Cap (N0370392)<br />
High-Sensitivity Nebulizer<br />
with Pt/Ir Capillary<br />
For Models AAnalyst 200/400/700*/800*<br />
Description Part No. Each (€)<br />
High-Sensitivity Nebulizer Assembly with<br />
Pt/Ir Capillary N3150188 423<br />
C<br />
1<br />
Components Part No. Each (€)<br />
Impact Bead Structure B0505086 63<br />
Nebulizer Spacer 09902015 6<br />
* Requires End Cap Assembly (N0370392)<br />
High-Sensitivity Nebulizer<br />
C 21 F<br />
22<br />
23 A E<br />
High-Sensitivity Nebulizer with Pt/Ir Capillary<br />
1<br />
C<br />
D<br />
Burner System Components Atomic Absorption<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
19
Burner System Components<br />
Nebulizers and Components<br />
Stainless Steel Body<br />
Nebulizers and Parts<br />
Atomic Absorption Burner System Components<br />
Stainless Steel Nebulizer<br />
1<br />
2<br />
6<br />
7<br />
11<br />
12<br />
16<br />
17<br />
8<br />
18<br />
3<br />
13<br />
1<br />
A<br />
11<br />
A<br />
B<br />
9<br />
B<br />
19<br />
4<br />
10<br />
14<br />
20<br />
5<br />
15<br />
For Models AAnalyst 100/300/700/800,* 5100 PC,<br />
5000, 3300, 3110, 3100, and Earlier AAs**<br />
Description Part No. Each (€)<br />
Stainless Steel Nebulizer Assembly 03030352 606<br />
1<br />
2<br />
3<br />
4<br />
5<br />
6<br />
7<br />
8<br />
9<br />
10<br />
A<br />
Description Part No. Each (€)<br />
O-Ring 09902005 1<br />
Insert 03031812 68<br />
Nebulizer Body 03030353 64<br />
Front End Cap 03031808 14<br />
O-Ring 09902239 1<br />
Adjustment Nut 03031460 41<br />
Locking Ring 03031456 9<br />
Washer 03031802 4<br />
O-Ring 09902102 1<br />
Spring 03031806 5<br />
/ B See chart on page 17<br />
* For AAnalyst spectrometers shipped starting Fall 1999<br />
** May be used on AAnalyst 200/400. Requires End Cap (00570984)<br />
For Models 4100, 2100, and 1100(B)<br />
Description Part No. Each (€)<br />
Stainless Steel Nebulizer Assembly N3110109 1001<br />
11<br />
12<br />
13<br />
14<br />
15<br />
16<br />
17<br />
18<br />
19<br />
20<br />
A<br />
Description Part No. Each (€)<br />
O-Ring B0045095 1<br />
Insert B0057336 31<br />
Nebulizer Body B0152456 88<br />
B0166507 159<br />
Front End Cap B0166502 15<br />
O-Ring B0148651 3<br />
Adjustment Nut B0166505 32<br />
B0057408 41<br />
Locking Ring B0166506 13<br />
B0057409 15<br />
Washer B0057334 6<br />
O-Ring B0057761 2<br />
Spring B0057410 5<br />
/ B See chart on page 17<br />
20
Flow Injection Sampling Supplies<br />
Flow Injection Analysis and Mercury Systems<br />
Flow Injection<br />
Analysis Systems (FIAS TM )<br />
PerkinElmer pioneered the use of flow injection techniques<br />
with atomic spectroscopy. The use of flow injection with<br />
AA, ICP, and ICP-MS saves time, costs and manpower,<br />
while at the same time extending your analytical flexibility<br />
and capabilities.<br />
The overall benefits include:<br />
Increased sample throughput<br />
Reduced reagent consumption<br />
Reduced sample volume<br />
Automated cold vapor mercury determinations using U.S.<br />
Environmental Protection Agency-approved methodology<br />
Automated hydride generation determinations<br />
Automated analyte preconcentration<br />
Matrix removal<br />
Automated sample dilution and reagent addition<br />
Enhanced performance for samples<br />
with high dissolved solids content<br />
Flow Injection<br />
Mercury Systems (FIMS TM )<br />
FIMS Tubing Diagram<br />
The Flow Injection Mercury System (FIMS) is an extremely<br />
small and easy-to-operate atomic absorption instrument<br />
dedicated to trace mercury determination. Based on flow<br />
injection techniques, it is fully automated, fast, and costeffective.<br />
FIMS provides exceptional sensitivity, precision,<br />
and detection limits.<br />
FIAS 100<br />
FIMS and Autosampler<br />
Flow Injection Sampling Supplies Atomic Absorption<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
21
Flow Injection Sampling Supplies<br />
FIAS and FIMS Parts and Supplies<br />
Atomic Absorption Flow Injection Sampling Supplies<br />
FIAS Cells and Supplies<br />
Quartz Cell 2 for FI-MHS<br />
Quartz Window<br />
Quartz Window Assembly<br />
Part of Quartz Cell 2.<br />
Universal Quartz Cell Holder<br />
Allows mounting of the FIAS-100/400<br />
Quartz Cell to Models 5100, 3030, 2380,<br />
3300, 3110, 3100, and AAnalyst series.<br />
For use with the electrically heated<br />
cell assembly or an air-acetylene<br />
flame with<br />
suitable mount.<br />
Part No. Each (€)<br />
B0507486 854<br />
Note: If both NaBH 4 and SnCl 2 are to be used as reducing agents with FIAS<br />
systems configured for Hg/hydride determinations, it is strongly recommended<br />
that separate mixing manifolds, gas-liquid separators, quartz cells, and<br />
required tubing and connectors be dedicated for use with each<br />
reducing agent.<br />
FIMS Cells and Supplies<br />
See page 25 for a complete listing of fittings, tubing, and flow injection <strong>supplies</strong>.<br />
Absorption Cell Body<br />
Quartz Window Assembly<br />
Kit Includes: Part No. Each (€)<br />
Window B0066549 21<br />
Holder B3000243 12<br />
FIMS Source Mercury Lamp<br />
Mercury Lamp Extractor<br />
For removing mercury lamp.<br />
Silicone Sleeve<br />
For FIMS Cell Sample Inlet.<br />
Part No.<br />
Each (€)<br />
B0066549 21<br />
Part No.<br />
Each (€)<br />
B0507487 140<br />
Part No.<br />
Each (€)<br />
B3000350 338<br />
Part No.<br />
Part No.<br />
Each (€)<br />
B0510370 84<br />
Each (€)<br />
B0510487 214<br />
Part No.<br />
Each (€)<br />
B3000243 12<br />
Part No.<br />
Each (€)<br />
B0018283 11<br />
Silicone Tubing<br />
For FIMS Cell Exhaust Outlet, 3 m.<br />
Hg Scrubber Kit<br />
Traps mercury vapor from the FIMS system. Eliminates the<br />
need for an expensive exhaust vent.<br />
Recommended by the U.S. EPA.<br />
Included with FIMS-100/400.<br />
Part No.<br />
B3000277<br />
Each (€)<br />
134<br />
Hg Replacement Filter<br />
Gas/Liquid Separator Consumables<br />
Gas/Liquid Separator<br />
Modular ‘building block’-type gas-liquid separator<br />
made from chemically resistant plastic. An<br />
exchangeable PTFE membrane in the screw cap<br />
of the separator prevents liquid from being carried<br />
into the quartz cell or ICP torch when working<br />
with strongly foaming samples.<br />
Part No. Each (€)<br />
(For ICP-MS use B0193772.)<br />
B0507959 147<br />
Mixing Manifold<br />
Modular ‘building block’-type mixing manifold with one<br />
mixing channel and three connections; two inlet, and one<br />
outlet. Made from chemically resistant plastic. Several of these<br />
blocks can be ‘plugged’ together easily<br />
to create a single unit with enhanced<br />
mixing capabilities. Part of B0507957.<br />
Part No.<br />
B0507962<br />
Each (€)<br />
50<br />
Mixing/Separation Assembly<br />
Complete modular unit, consisting of two mixing manifolds<br />
with tubing adapters K and M, a gas-liquid separator with a<br />
PTFE membrane, five spare PTFE<br />
membranes, one PTFE tube (110 mm<br />
long), and one PTFE tube (300 mm long).<br />
Part No.<br />
B0507957<br />
Each (€)<br />
504<br />
Chemifold<br />
For use with Glass Gas/Liquid Separator.<br />
Gas/Liquid Separator Holder<br />
for Glass Separator<br />
Glass Gas/Liquid Separator<br />
PTFE Membrane<br />
For use with the B0507959<br />
Gas/Liquid Separator. (pkg. 50)<br />
Plug Connector<br />
For connection of the mixing manifold<br />
and gas/liquid separator blocks.<br />
Part No.<br />
Each (€)<br />
B0046948 3<br />
Part No.<br />
Each (€)<br />
B3000274 107<br />
Part No.<br />
Each (€)<br />
B0187258 402<br />
Part No.<br />
Each (€)<br />
B0509479 377<br />
Part No.<br />
Each (€)<br />
B0193772 204<br />
Part No.<br />
Each (€)<br />
B0508306 319<br />
Part No.<br />
Each (€)<br />
B0507960 13<br />
22
Flow Injection Sampling Supplies<br />
FIAS and FIMS Parts and Supplies<br />
Pump Magazines<br />
Magazine for Peristaltic Pump<br />
One wide (>2 mm) tubing channel.<br />
Magazine for Peristaltic Pump<br />
Two narrow (
Flow Injection Sampling Supplies<br />
FIAS and FIMS Tubing Adapters and Connectors<br />
Flow Injection Sampling Supplies<br />
Adapters with External Threads<br />
Type Description Part No. Each (€)<br />
K / L<br />
1/4 in. (6.4 mm)<br />
External Screw Thread,<br />
K = 1.8 mm o.d. Nipple. B0507918 14<br />
L = 2.8 mm o.d. Nipple. B0507920 16<br />
M 1/4 in. (6.4 mm) B0507919 15<br />
External Screw Thread,<br />
4 mm o.d. Nipple.<br />
N 1/4 in. (6.4 mm) External B0507949 40<br />
Screw Thread, 0.7 mm o.d.<br />
Pt/lr Capillary Nipple.<br />
Screw Plug B0507921 9<br />
1/4 in. (6.4 mm)<br />
External Screw Thread.<br />
Adapters with Internal Threads<br />
Type Description Part No. Each (€)<br />
Connectors<br />
Type Description Part No. Each (€)<br />
IA Connector with Nipples B0199233 4<br />
for 1.7 to 3.2 mm<br />
i.d. tubes.<br />
IB Connector with Nipples B0196882 1<br />
for 2.4 to 3.2 mm<br />
i.d. tubes.<br />
II Connector with 1/4 in. B0196704 3<br />
(6.4 mm) Internal<br />
Screw Thread.<br />
IIIA T-piece with Nipples B0199035 14<br />
for 1.5 to 2.5 mm<br />
i.d. tubes.<br />
IIIB T-piece with Nipples B0198201 17<br />
for 3.5 to 4.5 mm<br />
i.d. tubes.<br />
A / B<br />
1/4 in. (6.4 mm)<br />
Internal Screw Thread,<br />
A = 1.8 mm o.d. Nipple. B0193342 12<br />
B = 3.3 mm o.d. Nipple. B0506716 40<br />
Screw Connector Tightening Tool<br />
For convenient tightening and loosening<br />
of the screw connectors used with<br />
PTFE tubing assemblies.<br />
Part No. Each (€)<br />
B0501315 47<br />
C 1/4 in. (6.4 mm) B0196850 38<br />
Internal Screw Thread,<br />
4 mm o.d. Nipple.<br />
E 1/4 in. (6.4 mm) B0196857 38<br />
Internal Screw Thread,<br />
for the Quartz Cell.<br />
F 1/4 in. (6.4 mm) Internal B0193873 57<br />
Screw Thread, 0.7 mm o.d.<br />
Pt/lr Capillary Nipple.<br />
G 1/4 in. (6.4 mm) Internal B0501580 71<br />
Screw Thread, Two Nipples<br />
to connect tubes to the<br />
Preconcentration Accessory.<br />
K<br />
II<br />
II<br />
E<br />
I<br />
FIAS-400<br />
K<br />
24
Flow Injection Sampling Supplies<br />
FIAS and FIMS Tubing and Supplies<br />
Peristaltic Pump Tubing<br />
Peristaltic Pump Tubing<br />
Peristaltic pump tubing has a wall thickness of 0.84 mm unless<br />
noted otherwise. Part numbers are for a package of 12 pieces.<br />
i.d. (mm) Color Code Part No. Each (€)<br />
0.76 Black/Black B0506058 37<br />
1.14 Red/Red B0193160 37<br />
1.52 Yellow/Blue B0193161 37<br />
2.06 Violet/Violet B0199034 37<br />
3.18 Black/White B0508310 37<br />
Peristaltic Pump Tubing, Solvent-Resistant<br />
White/white, 0.84 mm i.d.<br />
Resistant to organic solvents. (pkg. 12)<br />
PVC Waste Tubing<br />
3 mm i.d. with 1 mm wall thickness,<br />
no fittings. Price per meter.<br />
Silicone Tubing<br />
1 m x 5 mm i.d., no fittings.<br />
PTFE Tubing, Screw<br />
Connectors, and O-Rings<br />
Part No.<br />
Part No.<br />
The following are part numbers for PTFE tubing, O-Rings,<br />
and screw connectors to prepare tubing assemblies.<br />
Each (€)<br />
B0048139 1<br />
Part No.<br />
Each (€)<br />
B0507692 62<br />
Each (€)<br />
B0018283 11<br />
PTFE Tubing<br />
Part No. B0198097<br />
PTFE Tubing Assemblies<br />
Color<br />
i.d (mm) (Screw Fittings) Length (mm) Part No. Each (€)<br />
1.0 Blue 700 B0191059 29<br />
1.0 Blue 110 B0191058 19<br />
1.0 Blue 300 B0198097 19<br />
1.0 Blue 1000 B0191060 19<br />
1.75 Black 250 B0198099 61<br />
1.75 Black 450 B0198100 61<br />
0.35 White 60 B0501594 34<br />
Flanging Tool<br />
Used with PTFE tubing, screw<br />
connectors, and O-Rings to make<br />
tubing assemblies.<br />
Screw Connectors<br />
Color Description Part No. Each (€)<br />
White For 0.35 mm i.d. PTFE Tubing B0502923 1<br />
Red For 0.5 mm i.d. PTFE Tubing B0181354 1<br />
Green For 0.7 mm i.d. PTFE Tubing B0502924 1<br />
Blue For 1.0 mm i.d. PTFE Tubing B0502925 1<br />
Black For 1.75 mm i.d. PTFE Tubing B0502921 1<br />
Note: These connectors are all the same size.<br />
The color code is a universal system to denote the tubing i.d.<br />
O-Rings<br />
Description Part No. Each (€)<br />
For 0.35 - 1.0 mm i.d. Tubing B0507708 1<br />
For 1.75 mm i.d. Tubing B0045472 1<br />
PTFE Tubing (sold by meter)<br />
Tubing i.d. Part No. Each (€)<br />
0.35 mm B0506060 3<br />
0.5 mm B0507020 3<br />
0.7 mm B0507021 2<br />
1.0 mm B0029792 2<br />
1.75 mm B0017998 3<br />
Sample Loops<br />
Description Part No. Each (€)<br />
200 μL B0194048 36<br />
500 μL B0194049 36<br />
1000 μL B0501000 55<br />
3-D Reaction Coil<br />
3-dimensional reactor, 0.35 i.d.<br />
(two flanged ends).<br />
Part No.<br />
Each (€)<br />
B3000001 198<br />
Part No.<br />
Each (€)<br />
B0501595 64<br />
Flow Injection Sampling Supplies Atomic Absorption<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
25
Flow Injection Sampling Supplies<br />
Flow Injection Amalgamation System<br />
Atomic Absorption Flow Injection Sampling Supplies<br />
Amalgamation System and Supplies<br />
1<br />
1<br />
8<br />
7<br />
6 4<br />
5<br />
2<br />
6 9<br />
3<br />
5<br />
8<br />
5<br />
III<br />
Flow Injection Amalgamation System<br />
Provides increased sensitivity for the determination of<br />
mercury by amalgamation of Hg on a Au/Pt gauze. Mercury<br />
collected is quantitatively released by a controlled, rapid<br />
heating of the gauze.<br />
Part No. Each (€)<br />
B0191090 5100<br />
Components Part No. Each (€)<br />
1 Quartz Tube with Au/Pt Gauze B0193793 395<br />
2 Glass Fiber Filter Holder B0507777 363<br />
3<br />
May be used in place of drying tube<br />
Glass Fiber Filter, pkg. 20 B0507779 27<br />
Drying Tube B0198104 54<br />
54<br />
Wash Flask, 10 mL B0505326 105<br />
6III<br />
Connector, “T”-type B0198201 17<br />
7 Sample Loop, 1000 μL B0501000 55<br />
85<br />
PTFE Tubing B0198099 61<br />
1.75 mm i.d., 250 mm length<br />
86<br />
PTFE Tubing B0198100 61<br />
7<br />
1.75 mm i.d., 450 mm length<br />
Silicone Tubing B0018283 11<br />
8<br />
5 mm i.d., 1 m<br />
Silicone Tubing B0070126 9<br />
3 mm i.d., 1 m<br />
Air Filter B0502706 15<br />
9 One-way Valve B0198111 96<br />
26
Flow Injection Sampling Supplies<br />
Flow Injection Furnace Supplies<br />
FIAS-Furnace Coupling Kit and Supplies<br />
The direct coupling of flow injection with a graphite furnace<br />
atomic absorption automates on-line element preconcentration<br />
in the graphite tube, improving detection limits for the hydrideforming<br />
elements and for mercury by a factor of up to 500.<br />
FIAS-Furnace Coupling Kit<br />
For coupling a FIAS-400 with a 4110 ZL, AAnalyst 400<br />
(with HGA-900), AAnalyst 600, AAnalyst 700, AAnalyst<br />
800, or SIMAA TM 6100/6000 Graphite Furnace System.<br />
The kit consists of a sample transfer tube, a quartz pipette<br />
tip, a 50 mL bottle Iridium standard<br />
solution, and a FIAS-Furnace user guide. Part No. Each (€)<br />
HCl<br />
NaBH 4<br />
P1<br />
P2<br />
Waste<br />
Sample<br />
B3140255 654<br />
FIA Valve<br />
FIAS-Furnace Sample<br />
Transfer Tube*<br />
Quartz Pipette Tip*<br />
20 mm. (pkg.1)<br />
Silicone Tube*<br />
1 m.<br />
* Included in the FIAS-Furnace Coupling Kit (B3140255)<br />
Argon<br />
Flow Diagram for FIAS-Furnace Coupling<br />
Gas/Liquid-Separator<br />
Part No.<br />
Capillary<br />
Graphite Tube<br />
Each (€)<br />
B0509612 119<br />
Part No.<br />
Each (€)<br />
B0510032 35<br />
Part No.<br />
Each (€)<br />
B0029796 4<br />
Flow Injection Sampling Supplies Atomic Absorption<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
27
Flow Injection Sampling Supplies<br />
Flow Injection Preconcentration Kit and Supplies<br />
Atomic Absorption Flow Injection Sampling Supplies<br />
Flow Injection Sampling<br />
Valves and Supplies<br />
2<br />
Peristaltic Pump Tubing<br />
Components Part No. Each (€)<br />
FI Sampling Valve, 5-Port B0507914 714<br />
FI Sampling Valve, 8-Port B0509095 1418<br />
Valve Dismantling Tool B0509590 4<br />
Threaded Plug B0500695 468<br />
To close off port on<br />
5-port valve<br />
Peristaltic pump tubing has a wall thickness<br />
of 0.84 mm unless noted otherwise.<br />
7<br />
8<br />
9<br />
Components Part No. Each (€)<br />
Tubing (pkg. 12) B0193161 37<br />
1.52 mm i.d., Yellow/Blue<br />
Tubing (pkg. 12) B0506058 37<br />
0.76 mm i.d., Black/Black<br />
Tubing (pkg. 12) B0507692 62<br />
1 mm i.d., White/White<br />
Resistant to organic solvents<br />
Preconcentration Columns<br />
1<br />
1<br />
1<br />
Components Part No. Each (€)<br />
C 18 Preconcentration Column B0504047 689<br />
PTFE column packed with silica-immobilized<br />
C 18 Material. (Pkg.10)<br />
XAD-8 Preconcentration Column B0504048 689<br />
PTFE column packed with XAD-8 Material. (Pkg.10)<br />
Cr Preconcentration Column B0509561 631<br />
Alumina column for speciation of<br />
Cr (III) and Cr (Vi). (Pkg.10)<br />
A<br />
3<br />
A<br />
3<br />
A<br />
9<br />
PTFE Tubing Assemblies<br />
3<br />
4<br />
5<br />
6<br />
In the PTFE tubing assemblies described<br />
below, the numbers in parentheses refer to<br />
the length of the tubing assembly and the<br />
number of flanged ends with screw fittings.<br />
Components Part No. Each (€)<br />
PTFE Tubing Assembly B0191059 29<br />
Carrier or reagent container to peristaltic<br />
pump tubing, 1 mm i.d. (700 mm x 1 flanged end)<br />
PTFE Tubing Assembly B0191058 19<br />
Manifold to manifold and to tubing adapter C,<br />
1 mm i.d. (110 mm x 2 flanged ends)<br />
PTFE Tubing Assembly B0501594 34<br />
Valve to preconcentration column,<br />
0.35 mm i.d. (60 mm x 2 flanged ends)<br />
PTFE Tubing Assembly B0501595 64<br />
3-dimensional reactor, 0.35 mm i.d.<br />
(two flanged ends)<br />
Tubing Adapters and Connectors<br />
7<br />
A<br />
C<br />
G<br />
II<br />
A<br />
5<br />
4<br />
1<br />
2<br />
8 C<br />
5<br />
G<br />
Components Part No. Each (€)<br />
Tubing Adapter A B0193342 12<br />
Connects thin (1 to 2 mm i.d.) peristaltic<br />
pump tubing with the PTFE tubing screw fittings<br />
Tubing Adapter C B0196850 38<br />
Connects to 3 mm waste tubing<br />
Tubing Adapter G B0501580 71<br />
For peristaltic pump tubing to merge<br />
chelate and sample streams<br />
Tubing Connector Type II B0196704 3<br />
Connects two PTFE tubing screw fittings<br />
4<br />
II<br />
C<br />
6<br />
28
Graphite Furnace<br />
Graphite Tubes and Supplies<br />
Trust Your Analysis to<br />
Genuine PerkinElmer Graphite<br />
Rely on PerkinElmer graphite<br />
for consistent analytical results.<br />
Every sample. Every day.<br />
We Start With an Exclusive Grade of Graphite<br />
The production of high-quality graphite<br />
components requires stringent quality control.<br />
Selection and careful control of raw materials are<br />
extremely important.<br />
The composition and the microstructure of the<br />
base graphite material determines the resistivity<br />
of the tube and its heating characteristics. To<br />
ensure high quality and consistency, a specific<br />
high-density base graphite material has been<br />
developed for use with PerkinElmer graphite<br />
furnace systems. This base graphite material is<br />
used exclusively for the manufacturing of<br />
PerkinElmer’s graphite components.<br />
Our Tubes Are Manufactured<br />
and Tested to the Highest<br />
Quality Specifications<br />
During manufacturing, a comprehensive<br />
quality testing program — including<br />
extensive mechanical, electrical,<br />
thermal, and analytical testing<br />
procedures — is strictly followed.<br />
Each lot of graphite tubes is tested to<br />
demanding specifications for lifetime,<br />
sensitivity, and precision.<br />
Extensive testing ensures that all graphite<br />
components shipped by PerkinElmer<br />
provide consistent lot-to-lot performance.<br />
Our Pyrolytic Coating Design<br />
is Critical to Achieving<br />
High Performance<br />
The specified thickness of pyrolytic coating<br />
applied to PerkinElmer graphite improves<br />
the total resistance of the graphite tube and<br />
the temperature distribution within the<br />
tube. Improper pyrolytic coating can<br />
shorten tube lifetime dramatically.<br />
The microstructure and density of the<br />
surface are important parameters for the<br />
atomization kinetics of analyte elements.<br />
Irreproducible surface qualities will cause<br />
changes in the optimal drying, pyrolysis<br />
and atomization temperatures, peak shape<br />
and characteristic mass. PerkinElmer’s<br />
coating specification and quality control<br />
ensure consistency from tube to tube.<br />
You Can Depend on<br />
Our Extensive Experience<br />
PerkinElmer has over three decades<br />
of experience in the design and<br />
development of graphite furnace<br />
systems and materials. Years of<br />
PerkinElmer development have<br />
yielded the best possible graphite<br />
for atomic absorption.<br />
Any other graphite has not been<br />
optimized for use with PerkinElmer<br />
instruments and may yield<br />
inaccurate analytical results.<br />
29
Graphite Furnace<br />
Graphite Tubes and Supplies<br />
Do Not Accept Imitations<br />
Graphite components offered by other companies<br />
often refer to the PerkinElmer part, implying that these<br />
components are made from the same material and provide<br />
equivalent performance. This is misleading, as these<br />
imitation components are not made from the same<br />
base graphite material, nor are they tested to the same<br />
demanding quality control specifications. The different<br />
base graphite material will alter the temperature<br />
calibration, the heating rates, and the performance<br />
characteristics.<br />
Rely on Genuine PerkinElmer Graphite<br />
Today’s analysts expect exceptional analytical performance<br />
from their graphite furnace atomic absorption spectrometers.<br />
That performance must be stable and reproducible from<br />
day to day with respect to sensitivity (characteristic mass),<br />
accuracy, and precision.<br />
The graphite tube, the heart of the graphite furnace, plays<br />
a vital role in the overall stability of an analysis. In order<br />
to assure stable analytical conditions from one atomization<br />
cycle to the next, and from graphite tube to graphite tube,<br />
all graphite parts – contacts, tubes, and platforms –<br />
must be under strict quality control by both the instrument<br />
manufacturer and the graphite manufacturer. PerkinElmer<br />
graphite components continue to set the industry standard<br />
for quality.<br />
The proper performance, maintenance, and serviceability<br />
of your graphite furnace system can be assured only<br />
through the use of genuine, high-quality PerkinElmer<br />
graphite components.<br />
How is High-Quality Graphite Manufactured?<br />
■ Select carefully chosen raw materials that are exclusive to PerkinElmer<br />
■ Mill and mix the components with precision<br />
■ Utilize the proper pressing techniques<br />
■ Employ the correct heat treatments at carefully selected times<br />
■ Purify materials at multiple times throughout the process<br />
■ Apply special coating technology for pyrolytic products<br />
■ Test and qualify graphite against rigorous PerkinElmer standards<br />
■ Machine patented PerkinElmer designs using specialized techniques<br />
30
Contact Cylinders<br />
The graphite contact cylinders used in the HGA ® Graphite<br />
Furnace are engineered for a precise fit so that variations<br />
in electrical contact – which might affect the analytical<br />
performance – are reduced to a minimum. The graphite<br />
contacts are shaped so that they completely encase the<br />
graphite tube. Thus, the graphite tube is located in a<br />
defined inert environment, which ensures uniform<br />
heating conditions and long tube lifetime.<br />
Contact Cylinders for HGA-500/400 Furnaces<br />
Includes left-hand Contact, right-hand Contact, Shield Ring.<br />
Description Part No. Each (€)<br />
5 sets B0180363 492<br />
Contact Cylinders for Zeeman HGA Furnaces<br />
Includes left-hand Contact, right-hand Contact.<br />
Description Part No. Each (€)<br />
1 set B0116823 130<br />
5 sets B0180361 617<br />
Contact Cylinders for<br />
HGA-900/850/800/700/600/300 Furnaces<br />
Includes left-hand Contact, right-hand Contact, Shield Ring.<br />
Description Part No. Each (€)<br />
1 set B0128495 107<br />
5 sets B3130086 506<br />
Contact Cylinders Removal Tool<br />
Description Part No. Each (€)<br />
For HGA-300/400/500/600/700/800 Furnaces B0098258 536<br />
For HGA-600 Zeeman Furnaces B0127431 472<br />
For AAnalyst 700 and HGA-850/900 B3121301 320<br />
Graphite Furnace Tubes and Supplies<br />
HGA Graphite Contact Cylinders, Tubes, and Supplies<br />
For Zeeman HGA Furnaces<br />
Part No. B0120242<br />
Graphite Tube Alignment Tools<br />
Description Part No. Each (€)<br />
For Non-Zeeman Furnaces B0080112 80<br />
For Zeeman HGA Furnaces B0120242 80<br />
L’vov Platforms<br />
The L’vov Platform is a small plate of solid pyrocoated<br />
graphite that is inserted into the graphite tube. It has a slight<br />
depression in the center which can accommodate up to 50 μL<br />
of solution. The function of the L’vov Platform is to isolate<br />
the sample from the tube walls to allow more reproducible<br />
atomization of the sample through indirect heating. The<br />
platform heats primarily by the radiation given off from the<br />
tube walls. Sample vaporization and atomization occur after<br />
the tube reaches a steady-state temperature.<br />
Use of the L’vov Platform provides:<br />
■ Vaporization into a higher temperature gas atmosphere<br />
producing more free atoms, which reduce interferences<br />
■<br />
For Non-Zeeman Furnaces<br />
Part No. B0080112<br />
Longer tube life because aggressive samples are only<br />
in contact with the solid pyrolytic graphite platform<br />
Description Part No. Each (€)<br />
5-pack B0137112 104<br />
20-pack B3001256 394<br />
50-pack B0109324 935<br />
100-pack N3110145 1765<br />
Graphite Furnace Tubes and Supplies Atomic Absorption<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
31
Atomic Absorption Graphite Furnace Tubes and Supplies<br />
Graphite Furnace Tubes and Supplies<br />
HGA Graphite Contact Cylinders, Tubes, and Supplies<br />
Matrix Modifiers for<br />
Graphite Furnace AA<br />
■<br />
■<br />
■<br />
High-purity compounds minimize<br />
the risk of contamination<br />
Optimum graphite furnace program<br />
can be used due to reduced<br />
analyte volatility<br />
Convenient, ready-to-use<br />
Modifier Concentration Volume (mL) Part No. Each (€)<br />
Mg(No 3 ) 2 1% Mg (as nitrate) 100 B0190634 71<br />
Pd 1% Pd (as nitrate) 50 B0190635 249<br />
NH 4 H 2 PO4 10% NH 4 H 2 PO4 100 N9303445 101<br />
Pyrocoated Graphite Tubes (Grooved)<br />
for use with L’vov Platforms<br />
Pyrocoated Graphite Tubes (Grooved)<br />
Internally grooved to accept L’vov Platforms.<br />
Description Part No. Each (€)<br />
5-pack B0137111 237<br />
20-pack B3001254 900<br />
50-pack B0109322 2131<br />
100-pack N3110146 4026<br />
Cross-section of the PerkinElmer HGA graphite tube<br />
with manually inserted L’vov platform.<br />
HGA Furnace Mirror<br />
Part No.<br />
Uncoated Graphite Tubes Part No. B0070699<br />
Each (€)<br />
B0080259 83<br />
Pyrocoated Graphite Tubes<br />
with Integrated Platforms<br />
Graphite tubes with integrated platforms are machined from<br />
one piece of graphite and are totally pyrocoated, providing<br />
exceptional tube-to-tube reproducibility.<br />
The spherically shaped platform<br />
accommodates up to 50 μL of sample.<br />
Pyrocoated Graphite Tubes with<br />
Integrated Platforms Part No. B3001262<br />
Graphite tubes with integrated platforms:<br />
■<br />
■<br />
■<br />
Provide STPF conditions for volatile and nonvolatile refractory<br />
elements due to the significantly higher heating rates of tube<br />
and platform, which can be used for all elements<br />
Offer an extra measure of convenience versus manually<br />
inserting a separate platform<br />
Provide longer life with many aggressive sample matrices,<br />
such as concentrated acids<br />
Cross-section of the PerkinElmer HGA graphite tube<br />
with integrated platform.<br />
Pyrocoated Graphite Tubes with Integrated Platforms<br />
Description Part No. Each (€)<br />
5-pack B3001262 317<br />
20-pack B3001264 1138<br />
100-pack N3110149 5400<br />
Pyrocoated Graphite Tubes*<br />
Description Part No. Each (€)<br />
5-pack B0105197 213<br />
10-pack B0135653 403<br />
20-pack B3000342 765<br />
50-pack B0091504 1808<br />
* Not compatible with L’vov Platforms.<br />
Uncoated Graphite Tubes*<br />
Description Part No. Each (€)<br />
50-pack B0070699 965<br />
* Not compatible with L’vov Platforms.<br />
32
Circulatory Cooling System<br />
HGA Circulatory Cooling System for HGA-800/850/900<br />
Voltage Part No. Each (€)<br />
115 V, 60 Hz B3001124 4323<br />
230 V, 50/60 Hz B3001123 4323<br />
Glycerol<br />
(85% for cooling systems), 1 L<br />
Quartz Windows<br />
The HGA Graphite Furnace Assembly is sealed at both ends<br />
with easily removable quartz windows. This closed-furnace<br />
design is a prerequisite for controlled and reproducible<br />
internal analytical conditions.<br />
Model Window Part No. Each (€)<br />
AAnalyst 700/HGA-850/900 Left- and Right-hand B0080850 109<br />
Model Window (small window) Part No. Each (€)<br />
Zeeman 5X00<br />
Zeeman 3030<br />
HGA-300/400/500<br />
HGA-600/700<br />
HGA-800<br />
Right-hand<br />
Right-hand<br />
Left- and Right-hand<br />
Right-hand<br />
Left-hand<br />
Graphite Furnace Tubes and Supplies<br />
HGA Graphite Cooling Systems and Quartz Windows<br />
B0066549 21<br />
Model Window (large window) Part No. Each (€)<br />
Zeeman 3030, 5X00<br />
HGA-600/700<br />
HGA-800<br />
1<br />
2<br />
3<br />
4<br />
5<br />
Left-hand<br />
Left-hand<br />
Right-hand<br />
Quartz Window Components<br />
Part No.<br />
Each (€)<br />
B3141064 29<br />
B0115576 43<br />
Components Part No. Each (€)<br />
O-Ring B0047209 2<br />
Gasket* B0071145 1<br />
Window B0066549 21<br />
Window B0115576 43<br />
Gasket** B0104342 2<br />
* Use B0147153 on the HGA-800<br />
** Use B0196825 on HGA-600s and HGA-700s installed after May 1990<br />
1<br />
2<br />
HGA Circulatory Cooling System<br />
Part No. B3001124<br />
3<br />
4<br />
5<br />
Graphite Furnace Tubes and Supplies Atomic Absorption<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
33
Atomic Absorption Graphite Furnace Tubes and Supplies<br />
Graphite Furnace Tubes and Supplies<br />
THGA Graphite Contact Cylinders, Tubes, and Supplies<br />
Contact Cylinders<br />
The graphite contact cylinders are engineered for a precise<br />
fit so that variations in electrical contact – which might<br />
affect the analytical performance – are reduced to a<br />
minimum. Contact cylinders with a modified injection<br />
port area help to minimize condensation and improve<br />
analytical performance with difficult matrices.<br />
Standard THGA Contact Cylinders<br />
Description Part No. Each (€)<br />
1 pair B0504035 174<br />
5 pairs B0504036 824<br />
Modified THGA Contact Cylinders<br />
For improved analytical performance with samples that<br />
have a high concentration of dissolved salts or matrices<br />
with a high boiling point with transversely heated<br />
graphite furnaces.<br />
Description Part No. Each (€)<br />
1 pair B3002103 187<br />
5 pairs B3002102 886<br />
Accessories and Spare Parts<br />
Description Part No. Each (€)<br />
O-Ring (behind contact cylinder, front and back) B0500748 1<br />
Contact Cylinder Removal Tools B3120405 402<br />
Graphite Tubes<br />
Standard THGA Graphite Tube<br />
PerkinElmer’s unique, transverselyheated<br />
graphite tube includes an<br />
integrated platform. The exceptionally<br />
uniform temperature distribution<br />
obtained with transverse heating<br />
significantly reduces or eliminates<br />
condensation of the sample matrix<br />
components and “memory” effects, and improves the<br />
atomization efficiency for refractory elements.<br />
Description Part No. Each (€)<br />
5-pack B3000641 600<br />
20-pack B0504033 2156<br />
100-pack N3110147 10200<br />
Standard THGA Graphite Tube with End Cap*<br />
■<br />
■<br />
For improved characteristic<br />
mass with volatile and<br />
medium refractory elements<br />
such as Ag, As, Cd, Co, Cr<br />
Cu, Pb, Se, and Tl, the THGA<br />
graphite tubes with end caps<br />
are recommended.<br />
Improved detection limits for volatile and medium<br />
refractory elements<br />
Faster drying for complex matrices due to enlarged<br />
dosing hole<br />
Description Part No. Each (€)<br />
5-pack B3000653 612<br />
20-pack B3000655 2200<br />
* Not recommended for refractory elements such as V or Ba.<br />
UltraClean THGA Graphite Tube<br />
Cross-section of the<br />
PerkinElmer THGA<br />
transversely-heated<br />
graphite tube with<br />
integrated platform<br />
and end cap<br />
For the lowest possible detection limits, residual contaminant<br />
levels may not be low enough to meet your requirements. For<br />
the most demanding analyses, PerkinElmer offers UltraClean<br />
THGA graphite tubes – delivering exceptionally low levels of<br />
contamination due to advanced high-temperature gas-phase<br />
cleaning procedures. UltraClean graphite tubes offer<br />
unmatched analytical advantages for special applications<br />
such as the determination of extremely low traces of Na,<br />
Ca, Fe, Cr, and Ni in ultra-clean reagents used in the<br />
semiconductor industry, and ultra-trace analyses of<br />
environmental, clinical, or food samples.<br />
Key Benefits<br />
■ UltraClean THGA graphite tubes have the lowest possible<br />
contamination levels due to extensive high-temperature<br />
gas-phase cleaning procedures<br />
■ UltraClean THGA graphite tubes are tested and specified<br />
for blank levels of Cr, Ni, V, Mo, Ti (
Matrix Modifiers for<br />
Graphite Furnace AA<br />
■<br />
■<br />
■<br />
High purity compounds minimize the risk of contamination<br />
Optimum graphite furnace program can be used due to<br />
reduced analyte volatility<br />
Convenient, ready-to-use<br />
Modifier Concentration Volume (mL) Part No. Each (€)<br />
Mg(No 3 ) 2 1% Mg (as nitrate) 100 B0190634 71<br />
Pd 1% Pd (as nitrate) 50 B0190635 249<br />
NH 4 H 2 PO4 10% NH 4 H 2 PO4 100 N9303445 101<br />
Spare Parts and Supplies<br />
Circulatory Cooling System for use<br />
with THGA Furnace Systems<br />
230 V, 50/60 Hz.<br />
Quartz Window for the THGA<br />
O-Ring<br />
For Furnace Window.<br />
Rinse Funnel for Fume Extraction System<br />
Used to aspirate water.<br />
Spare Graphite Tip for the Fume Extraction System<br />
(1 piece).<br />
Graphite Furnace Tubes and Supplies<br />
THGA Graphite Contact Cylinders, Tubes, and Supplies<br />
Part No.<br />
Each (€)<br />
B0198072 3890<br />
Part No.<br />
Part No.<br />
Each (€)<br />
B0198005 120<br />
Each (€)<br />
B0501236 13<br />
Part No.<br />
Each (€)<br />
B0508836 13<br />
Part No.<br />
Each (€)<br />
B0506722 24<br />
THGA Furnace Mirror<br />
Used to optimize drying temperatures<br />
and times.<br />
THGA Graphite Tube Pliers<br />
Part No.<br />
Each (€)<br />
B0851900 85<br />
Part No.<br />
Each (€)<br />
09907925 8<br />
Graphite Furnace Tubes and Supplies Atomic Absorption<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
35
Laboratory Products<br />
Filters, Regulators, and Supplies<br />
Atomic Absorption Laboratory Products<br />
Filters<br />
Balston ® Air Filter Assembly Type A-82<br />
Replacement Air Filter<br />
Specifically designed to<br />
remove water, oil, and dirt<br />
particles down to 0.6 microns<br />
in diameter from compressed<br />
air lines. It is recommended for<br />
use with oil-type compressors,<br />
and for removing moisture and<br />
dirt particles from air supplied<br />
by oil-less compressors.<br />
Wilkerson ® Air Dryer Filter<br />
Provides clean air for burner<br />
controls used with AA<br />
spectrometers. It removes<br />
entrained water, oil, and water<br />
aerosols, and solid particles<br />
from compressed air lines. The<br />
pressure regulator reduces the<br />
air pressure, which decreases<br />
the relative humidity of the<br />
air and prevents further<br />
condensation. The final filter removes aerosols and particles<br />
which are small enough to pass through the pre-filter. Oil,<br />
if present, is collected on the coalescing-type final filter and<br />
drips to the bottom of the bowl. The assembly consists of a<br />
shut-off valve, a pre-filter with automatic drain, a pressure<br />
reducing regulator with pressure gauge, a final filter, and a<br />
final filter indicator.<br />
Part No. Each (€)<br />
Max Inlet Pressure: 150 psig<br />
00470652 555<br />
Replacement Filters<br />
Part No.<br />
Each (€)<br />
N0580531 281<br />
Part No.<br />
Each (€)<br />
N0582251 42<br />
Replacements (Pre-filter) Part No. Each (€)<br />
Filter Elements 09923464 19<br />
Filter Bowls N9302199 25<br />
Replacements (Final Filter) Part No. Each (€)<br />
Filter Elements 09907120 47<br />
Filter Bowls N9302199 25<br />
Bowl O-ring Kit N9302197 45<br />
Balston 95A Acetylene<br />
Acetylene Replacement<br />
Filter Cartridge<br />
Parker Balston 73-099 AA Gas Purifier<br />
Includes a Balston Grade<br />
BQ filter cartridge to remove<br />
liquid and solid contaminants<br />
from the acetylene supply to<br />
99.99% at 0.01 micron.<br />
Max Working Pressure: 15 psig<br />
A wall-mounted system designed<br />
to purify the compressed air and<br />
acetylene gases used in atomic<br />
absorption. It consists of two<br />
independent filtration systems,<br />
one for compressed air and<br />
one for acetylene. The unit<br />
also has a flashback arrestor<br />
on the acetylene line and a<br />
pressure regulator on the<br />
compressed air line.<br />
The two-stage air filtration<br />
assembly consists of a Balston Grade DX coalescing filter and<br />
a Balston Grade BX coalescing filter. Together these filters<br />
remove oil, water, and particulate contamination (99.99% at<br />
0.01 micron) from the compressed air supply.<br />
Replacement Cartridges<br />
Part No.<br />
Each (€)<br />
N9301399 312<br />
Part No.<br />
Each (€)<br />
N9301714 12<br />
Part No.<br />
Each (€)<br />
N9301398 1008<br />
1st Air Filter Part No. Each (€)<br />
Replacement Cartridges N9301710 18<br />
Replacement Seal Sets N9301712 17<br />
2nd Air Filter Part No. Each (€)<br />
Replacement Cartridges N9301711 18<br />
Replacement Seal Sets N9301712 17<br />
Acetylene Filter Part No. Each (€)<br />
Replacement Cartridges N9301714 12<br />
Replacement Seal Sets N9301715 10<br />
36
Laboratory Products<br />
Filters, Regulators, and Supplies<br />
Flash Arrestor<br />
Instrument Filters<br />
Filter Cartridge for Fume Extraction Separator Trap<br />
(pkg. 50)<br />
Part No. Each (€)<br />
B0509065 37<br />
Matheson Flashback Arrestor<br />
Because acetylene is an extremely unstable gas, users<br />
can experience flashbacks at the instrument burner head.<br />
The flash arrestor prevents these potentially dangerous<br />
flashbacks from reaching the regulator or cylinder.<br />
Acetylene Max Operating Pressure: 15 psig<br />
Positive shut-off of gas – checks the reverse flow under all<br />
conditions. Also stops gas supply when a flashback occurs.<br />
Hose Assemblies<br />
Acetylene, Red<br />
Part No. 00570559<br />
Hose Assemblies<br />
Part No.<br />
Air/Argon, Black<br />
Part No. 00570567<br />
Each (€)<br />
N9300068 312<br />
Hose assemblies for connecting fuel, air, and nitrous oxide<br />
from supply to instrument.<br />
Description Part No. Each (€)<br />
Acetylene, red, 3.7 m (12 ft.) long 00570559 80<br />
Air/Argon, black, 3.7 m (12 ft.) long 00570567 80<br />
Nitrous Oxide, blue, 3.7 m (12 ft.) long 00470258 116<br />
Instrument Filters<br />
Description Part No. Each (€)<br />
Filter for AA 100/300 09995097 21<br />
Filter for AA 200/400/600/700/800 B0501696 21<br />
Filter for AA 600/700/800 (80x80) B0502706 15<br />
SIMAA 6100/6000<br />
Rear filter. (pkg. 1)<br />
Square Filter Pads<br />
4100 ZL/4110 ZL, side and<br />
back filters. (pkg. 1)<br />
MiniDispenser<br />
Aqueous and organic solutions as well as acids (including HF)<br />
can be easily dispensed without the risk of sample contamination<br />
when using the high-precision MiniDispenser.<br />
Bottle Holder PP-250<br />
MiniDispenser<br />
Replacement Valve Kit<br />
For replacing MiniDispenser valves.<br />
Part No.<br />
Used to stabilize 250 mL<br />
plastic bottles such as supplied<br />
by Suprapur ® and<br />
Optima chemicals.<br />
Preassembled and tested.<br />
Includes GL45, S40, and<br />
38-430 bottle adapters.<br />
Each (€)<br />
B0502706 15<br />
Part No.<br />
Each (€)<br />
B0501252 3<br />
Part No.<br />
Each (€)<br />
B0511806 59<br />
Part No.<br />
Each (€)<br />
B0511778 201<br />
Part No.<br />
Each (€)<br />
B0511779 130<br />
Laboratory Products Atomic Absorption<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
37
Laboratory Products<br />
Filters, Regulators, and Supplies<br />
Regulators<br />
Acetylene Regulator<br />
Argon/Nitrogen Regulator<br />
Atomic Absorption Laboratory Products<br />
Air Regulator<br />
Venting System<br />
Includes an adapter<br />
so that the pressure<br />
regulator can be<br />
connected to cylinders<br />
requiring either CGA 300<br />
or CGA 510 fittings and<br />
a connector for attaching<br />
the fuel hose assembly<br />
supplied with the<br />
instrument. Includes<br />
hose assembly.<br />
Max Inlet Pressure:<br />
400 psig<br />
Part No.<br />
Regulator to cylinder<br />
CGA no. 590. Includes<br />
hose assembly.<br />
Max Inlet Pressure:<br />
3000 psig<br />
Venting System<br />
Each (€)<br />
03030106 446<br />
Part No.<br />
Each (€)<br />
03030264 446<br />
A venting system is<br />
required to remove fumes<br />
and vapors from the burner<br />
compartment of atomic<br />
absorption instruments.<br />
Includes exhaust hood,<br />
adapter, and blower.<br />
Note: Does not include ducting.<br />
PerkinElmer Service Engineers are<br />
not permitted to install this unit.<br />
Description Part No. Each (€)<br />
Blower and Vent Assembly 03030406 1218<br />
Exhaust Hood 03031910 236<br />
Nitrous Oxide Regulator<br />
Can be used with Argon<br />
or Nitrogen and has<br />
a CGA 580 fitting. A<br />
color-coded hose with<br />
1/4-inch SWAGELOK ®<br />
fittings is also included.<br />
Max Inlet Pressure:<br />
3000 psig<br />
Part No.<br />
Each (€)<br />
03030284 446<br />
For use with gas<br />
cylinders with a CGA 326<br />
connection. Provides<br />
pressure control from<br />
350-520 kPA (50-75 psig)<br />
and contains an integral<br />
thermostatted heater to<br />
prevent freezing of<br />
the regulator diaphragm.<br />
A color-coded hose with<br />
suitable connectors at<br />
each end is supplied<br />
with the regulators to<br />
provide connection to the<br />
instrument gas controls.<br />
Part No.<br />
Each (€)<br />
03030204 848<br />
38
Lamps for Atomic Absorption<br />
Lumina Hollow Cathode Lamps<br />
Genuine PerkinElmer<br />
Hollow Cathode Lamps<br />
for Atomic Absorption<br />
PerkinElmer’s expertise in the design and<br />
manufacture of light sources for atomic<br />
absorption spectrometers traces back to<br />
our original hollow cathode lamps, developed<br />
nearly 40 years ago.<br />
PerkinElmer manufactures a full range of singleelement<br />
and multi-element hollow cathode lamps<br />
and high-intensity electrodeless discharge lamps for<br />
those elements for which they are more effective.<br />
Every genuine PerkinElmer Lumina lamp is designed<br />
for use with, and tested on, our spectrometers to assure<br />
compatibility and the highest performance. To prolong<br />
the life of a Lumina hollow cathode lamp (HCL), we<br />
produce lamps with larger internal volume so that<br />
a greater supply of fill gas at optimum pressure is<br />
available. The larger the lamp, the greater the inert<br />
gas volume — and the longer the lamp lifetime.<br />
PerkinElmer offers a wide range of single-element and<br />
multi-element HCLs, which are ideal for determining<br />
most elements by atomic absorption spectroscopy.<br />
For the Widest Selection of Elements<br />
The basic components of a hollow cathode lamp (HCL) are a sealed glass<br />
cylinder filled with an inert gas (argon or neon), an anode, a cathode, and<br />
either glass or quartz end window. The cathode is a hollow cylinder of<br />
the element whose spectrum is to be produced, or in some cases, an alloy<br />
or carefully selected mixture of metals which do not spectrally interfere.<br />
Hollow cathode lamps emit light by the following process: The fill gas is<br />
ionized when an electrical potential is applied between the anode and<br />
the cathode. The positively charged ions collide with the negatively<br />
charged cathode and dislodge individual metal atoms in a process known<br />
as “sputtering.” These “sputtered” metal atoms are excited through<br />
impact with fill gas ions, and light of the specific wavelengths for that<br />
element is emitted when the atom “decays” from the excited state back<br />
to the more stable state.<br />
PerkinElmer Exclusive 6/24 WARRANTY*<br />
Lumina Hollow Cathode Lamps<br />
1. We warrant that during the first six months or after 5,000 milliampere-hours of operation,<br />
whichever comes first, from initial date of shipment, the lamps will meet or exceed the<br />
intensity and absorption specifications to which all new lamps are tested.<br />
2. All our hollow cathode lamps are warranted to light and emit the spectra of the element<br />
indicated for two years or 5,000 milliampere-hours of operation from the date of the<br />
shipment, whichever comes first.<br />
3. If any lamp fails before the expiration of the warranty period, it will be replaced free of charge.<br />
* The lamp warranty is void for lamps which sustain physical damage or are operated at power<br />
levels substantially above or below the power level recommended on the lamp label. The lamp<br />
warranty may vary in different countries.<br />
Features and Benefits<br />
■ Long Life: PerkinElmer’s larger ■ Quality: Carefully selected<br />
lamp volume results in longer materials used in the<br />
lamp lifetime<br />
manufacturing of our lamps<br />
■ Automation: PerkinElmer coded avoid spectral interference<br />
lamps allow automatic setup ■ Design: Our design provides you<br />
■ Easy Installation: It’s as simple with the low detection limits<br />
as sliding the lamp into the needed for your most difficult<br />
instrument’s lamp bracket<br />
determinations<br />
or turret<br />
■ Selection: PerkinElmer offers<br />
■ Timers: Each Lumina<br />
a wide selection of single-element<br />
hollow cathode lamp includes and multi-element lamps<br />
a milliampere-hour timer in its ■ Easy To Order: It’s easy to find<br />
base to monitor lamp usage the right lamp for your analytical<br />
■ Complete Compatibility: needs – simply use the selection<br />
Lumina hollow cathode lamps charts on page 40<br />
can be used with PerkinElmer’s ■ Warranty: The performance of<br />
entire range of atomic absorption every PerkinElmer lamp is<br />
spectrometers<br />
fully warranted<br />
■ Testing: Every lamp is thoroughly<br />
tested before leaving the factory<br />
39
Lamps for Atomic Absorption<br />
Lumina Hollow Cathode Lamps<br />
Lumina Lamps and Lamps with Adapters<br />
Atomic Absorption Lamps for Atomic Absorption<br />
Lumina coded hollow cathode lamps are available in two<br />
series: with and without an Intensitron adapter cable.<br />
Series N30501XX and N30502XX Lumina lamps<br />
do not include an Intensitron adapter cable and are<br />
designed to be used with PerkinElmer’s AAnalyst TM<br />
series of instruments.<br />
Series N30503XX and N30504XX Lumina lamps<br />
include an adapter cable that allows the lamps to be<br />
recognized by the following instruments: SIMAA TM<br />
6100/6000, 5100 (PC), 4110 ZL, 4100, 4100 ZL, 3300,<br />
2100, and 1100(B).<br />
Lumina hollow cathode lamps may also be used with<br />
all earlier AA spectrometers that do not have automatic<br />
code reading capability by using an appropriate<br />
adapter cable (refer to Adapter Cable on page 44).<br />
Lumina Lamp<br />
Lumina Plus Intensitron ®<br />
Element Element Lamp Adapter<br />
Name Symbol Part No. Each (€) Part No. Each (€)<br />
Aluminum Al* N3050103 483 N3050303 573<br />
Antimony Sb N3050170 573 N3050370 700<br />
Arsenic As N3050105 700 N3050305 828<br />
Barium Ba* N3050109 611 N3050309 738<br />
Beryllium Be* N3050110 802 N3050310 930<br />
Bismuth Bi N3050111 573 N3050311 675<br />
Boron B* N3050108 636 N3050308 764<br />
Cadmium Cd N3050115 547 N3050315 675<br />
Calcium** Ca N3050114 509 N3050314 636<br />
Chromium Cr N3050119 483 N3050319 611<br />
Cobalt Co N3050118 420 N3050318 547<br />
Copper*** Cu N3050121 420 N3050321 509<br />
Dysprosium Dy* N3050122 483 N3050322 663<br />
Erbium Er* N3050123 483 N3050323 663<br />
Europium Eu* N3050124 483 N3050324 611<br />
Gadolinium Gd* N3050129 483 N3050329 611<br />
Gallium Ga N3050128 509 N3050328 611<br />
Germanium Ge* N3050130 573 N3050330 700<br />
Gold Au N3050107 573 N3050307 700<br />
Hafnium Hf* N3050133 509 N3050333 663<br />
Holmium Ho* N3050135 599 N3050335 663<br />
Indium In N3050137 547 N3050337 636<br />
Iridium lr N3050138 802 N3050338 930<br />
Iron Fe N3050126 420 N3050326 509<br />
Lanthanum La* N3050141 636 N3050341 663<br />
Lead Pb N3050157 611 N3050357 738<br />
Lithium Li N3050142 509 N3050342 636<br />
Magnesium** Mg N3050144 483 N3050344 611<br />
Manganese Mn N3050145 509 N3050345 636<br />
Mercury Hg N3050134 547 N3050334 675<br />
Molybdenum Mo N3050146 483 N3050346 573<br />
Neodymium Nd* N3050150 483 N3050350 663<br />
Nickel Ni N3050152 420 N3050352 509<br />
Niobium Nb* N3050149 483 N3050349 573<br />
Palladium Pd N3050158 611 N3050358 738<br />
* This element requires a nitrous oxide-acetylene flame.<br />
** To measure secondary lines below 230 nm, choose the Ca/Mg/Zn lamp<br />
with quartz window.<br />
*** To measure secondary lines below 230 nm, choose the Cu/Fe/Mn/Zn lamp<br />
with quartz window.<br />
40
Lamps for Atomic Absorption<br />
Lumina Hollow Cathode Lamps<br />
Lumina Lamp<br />
Lumina Plus Intensitron ®<br />
Element Element Lamp Adapter<br />
Name Symbol Part No. Each (€) Part No. Each (€)<br />
Phosphorus P* N3050155 738 N3050355 866<br />
Platinum Pt N3050162 675 N3050362 802<br />
Potassium K N3050139 509 N3050339 611<br />
Praseodymium Pr* N3050161 599 N3050361 663<br />
Rhenium Re* N3050165 483 N3050365 759<br />
Rhodium Rh N3050166 675 N3050366 802<br />
Ruthenium Ru N3050168 738 N3050368 866<br />
Samarium Sm* N3050174 490 N3050374 663<br />
Scandium Sc* N3050171 573 N3050371 700<br />
Selenium Se N3050172 611 N3050372 738<br />
Silicon Si* N3050173 547 N3050373 675<br />
Silver Ag N3050102 483 N3050302 573<br />
Sodium Na N3050148 547 N3050348 675<br />
Strontium Sr N3050176 547 N3050376 675<br />
Tantalum Ta* N3050177 483 N3050377 611<br />
Tellurium Te N3050180 611 N3050380 738<br />
Terbium Tb* N3050178 547 N3050378 663<br />
Thallium Tl N3050183 547 N3050383 675<br />
Thulium Tm* N3050184 636 N3050384 764<br />
Tin Sn N3050175 547 N3050375 675<br />
Titanium Ti* N3050182 420 N3050382 547<br />
Tungsten W* N3050187 445 N3050387 547<br />
Vanadium V* N3050186 445 N3050386 573<br />
Ytterbium Yb* N3050190 509 N3050390 663<br />
Yttrium Y* N3050189 483 N3050389 611<br />
Zinc Zn N3050191 573 N3050391 700<br />
Zirconium Zr* N3050192 445 N3050392 573<br />
*This element requires a nitrous oxide-acetylene flame.<br />
Lamps for Atomic Absorption Atomic Absorption<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
41
Lamps for Atomic Absorption<br />
Lumina Hollow Cathode Lamps<br />
Lumina Multi-Element Hollow Cathode Lamps<br />
Atomic Absorption Lamps for Atomic Absorption<br />
Two-Element Lamps<br />
Lumina Lamp<br />
Lumina Lamp<br />
Lumina Plus Intensitron ®<br />
Lumina<br />
Plus Intensitron<br />
Element Element Lamp Adapter<br />
Element Element Lamp Adapter<br />
Name Symbol Part No. Each (€) Part No. Each (€) Name Symbol Part No. Each (€) Part No. Each (€)<br />
Ag-Au N3050201 509 N3050401 614 Ag-Cr-Cu-Fe-Ni N3050213 611 N3050413 802<br />
Silver Ag<br />
Silver Ag<br />
Gold Au<br />
Chromium Cr<br />
Ca-Mg* N3050202 611 N3050402 738 Copper Cu<br />
Calcium Ca<br />
Iron Fe<br />
Magnesium Mg<br />
Nickel Ni<br />
Ca-Zn N3050203 636 N3050403 764 Co-Cr-Cu-Mn-Ni N3050214 611 N3050414 738<br />
Calcium Ca<br />
Cobalt Co<br />
Zinc Zn<br />
Chromium Cr<br />
K-Na N3050204 611 N3050404 700 Copper Cu<br />
Potassium K<br />
Manganese Mn<br />
Sodium Na<br />
Nickel Ni<br />
Pt-Ru N3050205 802 N3050405 930 Co-Cu-Fe-Mn-Mo N3050215 636 N3050415 764<br />
Platinum Pt<br />
Cobalt Co<br />
Ruthenium Ru<br />
Copper Cu<br />
Sn-Te N3050206 611 N3050406 663 Iron Fe<br />
Tin Sn<br />
Manganese Mn<br />
Tellurium Te<br />
Molybdenum Mo<br />
Three-Element Lamps<br />
Al † -Ca-Mg* N3050207 611 N3050407 738<br />
Aluminum Al<br />
Calcium Ca<br />
Magnesium Mg<br />
Ca-Mg-Zn N3050208 675 N3050408 802<br />
Calcium Ca<br />
Magnesium Mg<br />
Zinc Zn<br />
Cu-Fe-Ni N3050209 611 N3050409 738<br />
Copper Cu<br />
Iron Fe<br />
Nickel Ni<br />
Four-Element Lamps<br />
Ag-Cr-Cu-Ni N3050210 636 N3050410 802<br />
Silver Ag<br />
Chromium Cr<br />
Copper Cu<br />
Nickel Ni<br />
Al-Cu-Fe-Ti † N3050211 547 N3050411 675<br />
Aluminum Al<br />
Copper Cu<br />
Iron Fe<br />
Titanium Ti<br />
Cu-Fe-Mn-Zn N3050212 611 N3050412 738<br />
Copper Cu<br />
Iron Fe<br />
Manganese Mn<br />
Zinc Zn<br />
Five-Element Lamps<br />
Six-Element Lamps<br />
Ag-Al † -Cr-Cu-Fe-Mg N3050216 611 N3050416 738<br />
Silver Ag<br />
Alumiunum Al<br />
Chromium Cr<br />
Copper Cu<br />
Iron Fe<br />
Magnesium Mg<br />
Co-Cr-Cu-Fe-Mn-Ni N3050217 611 N3050417 738<br />
Cobalt Co<br />
Chromium Cr<br />
Copper Cu<br />
Iron Fe<br />
Manganese Mn<br />
Nickel Ni<br />
Seven-Element Lamps<br />
Al*-Ca-Cu-Fe-Mg-Si † -Zn N3050218 611 N3050418 738<br />
Aluminum Al<br />
Calcium Ca<br />
Copper Cu<br />
Iron Fe<br />
Magnesium Mg<br />
Silicon Si<br />
Zinc Zn<br />
* To measure secondary lines below 230 nm, choose the Ca/Mg/Zn lamp with<br />
quartz window or the Ag, Al, Cr, Cu, Fe, Mg, or Al, Ca, Cu, Fe, Mg, Si, Zn<br />
lamps with quartz windows.<br />
†<br />
This element requires a Nitrous Oxide-Acetylene flame.<br />
42
Lamps for Atomic Absorption<br />
Lumina Hollow Cathode Lamp Coded Adapters<br />
Coded Lumina Adapters<br />
Element<br />
Element<br />
Symbols Part No. Each (€) Symbols Part No. Each (€)<br />
Ag N3050702 74 Re N3050765 74<br />
Al N3050703 74 Rh N3050766 74<br />
As N3050705 74 Ru N3050768 74<br />
Au N3050707 74 Sb N3050770 74<br />
B N3050708 74 Sc N3050771 74<br />
Ba N3050709 74 Se N3050772 74<br />
Be N3050710 74 Si N3050773 74<br />
Bi N3050711 74 Sn N3050775 74<br />
Ca N3050714 74 Sr N3050776 74<br />
Cd N3050715 74 Ta N3050777 74<br />
Co N3050718 74 Tb N3050778 74<br />
Cr N3050719 74 Te N3050780 74<br />
Cu N3050721 74 Ti N3050782 74<br />
Dy N3050722 74 Tl N3050783 74<br />
Er N3050723 74 V N3050786 74<br />
Fe N3050726 74 W N3050787 74<br />
Ga N3050728 74 Y N3050789 74<br />
Gd N3050729 74 Zn N3050791 74<br />
Ge N3050730 74 Zr N3050792 74<br />
Hg N3050734 74 Ag-Au N3050801 74<br />
Ho N3050735 74 Ca-Mg N3050802 74<br />
In N3050737 74 Ca-Zn N3050803 74<br />
Ir N3050738 74 K-Na N3050804 74<br />
K N3050739 74 Pt-Ru N3050805 74<br />
La N3050741 74 Sn-Te N3050806 74<br />
Li N3050742 74 Al-Ca-Mg N3050807 74<br />
Mg N3050744 74 Ca-Mag-Zn N3050808 74<br />
Mn N3050745 74 Cu-Fe-Ni N3050809 74<br />
Mo N3050746 74 Ag-Cr-Cu-Ni N3050810 74<br />
Na N3050748 74 Al-Cu-Fe-Ti N3050811 74<br />
Nb N3050749 74 Cu-Fe-Mn-Zn N3050812 74<br />
Nd N3050750 74 Ag-Cr-Cu-Fe-Ni N3050813 74<br />
Ni N3050752 74 Co-Cr-Cu-Mn-Ni N3050814 74<br />
P N3050755 74 Co-Cu-Fe-Mn-Mo N3050815 74<br />
Pb N3050757 74 Ag-Al-Cr-Cu-Fe-Mg N3050816 74<br />
Pd N3050758 74 Co-Cr-Cu-Fe-Mn-Ni N3050817 74<br />
Pr N3050761 74 Al-Ca-Cu-Fe-Mg-Si-Zn N3050818 74<br />
Pt N3050762 74<br />
Lamp Adapters<br />
These adapters allow Lumina HCLs to be<br />
used on PerkinElmer’s wide range of atomic<br />
absorption spectrometers.<br />
Lumina Lamp with Intensitron Adapter Cable for use with<br />
Models SIMAA 6100/6000, 5100 (PC), 4110 ZL, 4100,<br />
4100 ZL, 3300, 2100, and 1100(B).<br />
Lamps for Atomic Absorption Atomic Absorption<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
43
Lamps for Atomic Absorption<br />
Non-Coded Hollow Cathode Lamp Adapters<br />
Lamp Plug Adapters<br />
Atomic Absorption Lamps for Atomic Absorption<br />
Coded Intensitron ® Lamp Plug Adapter<br />
Allows coded Intensitron HCLs (N06612XX series, 12 pin)<br />
to be used with PerkinElmer atomic absorption<br />
instruments with non-coded lamp<br />
connectors (9 pin).<br />
Part No. Each (€)<br />
N0660123 147<br />
Lumina Lamp Plug Adapter<br />
Allows Lumina HCLs (N305XXXX series, 4 pin)<br />
to be used with PerkinElmer atomic absorption<br />
instruments with non-coded lamp<br />
connectors (9 pin).<br />
Part No. Each (€)<br />
N3050198 41<br />
Non-Coded Intensitron Lamp Plug Adapter<br />
Allows non-coded Intensitron hollow cathode lamps<br />
(030360XX series, 9 pin) to be used with the Models 5100<br />
(PC), 3300, and 4100ZL (12 pin).<br />
Part No. Each (€)<br />
Non-Coded Intensitron Lamp Plug Adapter<br />
Allows non-coded Intensitron lamps (03036XXX<br />
series, 9 pin) to be used with AAnalyst<br />
instruments (4 pin).<br />
Part No. Each (€)<br />
N3050197 41<br />
Non-Coded Intensitron Lamp Plug Adapter<br />
N0660122 147<br />
Allows non-coded Intensitron HCLs (030360XX<br />
series, 9 pin) to be used with Models 4100, 4100 ZL,<br />
2100, and 1100(B) (12 pin). Not for use<br />
on SIMAA 6100/6000.<br />
Part No. Each (€)<br />
B0156094 236<br />
Universal Coded Intensitron Lamp Plug Adapter<br />
Allows coded lamps (N06612XX series, 12 pin) to be<br />
used with AAnalyst instruments (4 pin); however, an<br />
AAnalyst spectrometer does not recognize<br />
their coding.<br />
Part No. Each (€)<br />
N3050196 45<br />
44
Lamps for Atomic Absorption<br />
Supplies<br />
Background Corrector Sources<br />
For Instrument<br />
Source<br />
Models Type Part No. Each (€)<br />
AAnalyst 100/300, Deuterium N0370119 765<br />
3300, 3110, 3100<br />
AAnalyst 200/400 Deuterium B3150169 304<br />
AAnalyst 700/800 Deuterium B0148615 765<br />
2280, 2380, 280, 380 Deuterium 00570194 695<br />
3030(B)* Deuterium 00570194 695<br />
3030(B)** Deuterium B0127014 318<br />
4000, 5000, 5100, 5100 (PC), Tungsten-halide C0550500 69<br />
Zeeman/5000, Zeeman/5100 (PC)<br />
4100, 2100, 1100(B) Deuterium B0148615 765<br />
For all instruments except the AAnalyst series, we recommend that an<br />
authorized PerkinElmer Service Engineer install your Background Corrector<br />
Source. Installation is not included in the price.<br />
* For instruments with 10-digit serial numbers<br />
** For instruments with 4-digit serial numbers<br />
Supplies<br />
SIMAA 6100/6000 Quick-Change<br />
Lamp Mount Assembly<br />
Small Diameter Lamp Adapter Kit<br />
Permits the use of hollow cathode lamps of smaller diameter<br />
than the PerkinElmer 2 in. diameter hollow cathode lamps<br />
used in PerkinElmer atomic absorption spectrometers.<br />
Red Filter<br />
Part No.<br />
Part No.<br />
Linearizes working curves for potassium, lithium, rubidium,<br />
and cesium. Recommended for Rb and Cs determinations by<br />
flame emission. Passes only wavelengths longer than 650 nm.<br />
Many PerkinElmer atomic absorption spectrometers are<br />
equipped with a filter holder for easy use.<br />
Part No.<br />
Each (€)<br />
B3000656 166<br />
Each (€)<br />
N3051050 152<br />
Each (€)<br />
02901518 70<br />
Background Corrector Source<br />
(For AAnalyst 100/300 and models<br />
3300, 3110, 3100)<br />
Part No. N0370119<br />
Small Diameter Lamp Adapter Kit Part No. N3051050<br />
Lamps for Atomic Absorption Atomic Absorption<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
45
Lamps for Atomic Absorption<br />
System 2 EDL Lamps<br />
System 2 Electrodeless<br />
Discharge Lamps<br />
Maximum Intensity and Long Life<br />
While hollow cathode lamps are an ideal source<br />
for determining most elements by atomic<br />
absorption, for volatile elements we recommend<br />
the use of electrodeless discharge lamps.<br />
EDLs provide greater light output and longer life than<br />
corresponding HCLs. For certain elements, such as Arsenic<br />
and Selenium, EDLs will also provide improved sensitivity<br />
and lower detection limits. System 2 electrodeless discharge<br />
lamps provide the optimized spectral output needed to get<br />
the maximum performance from PerkinElmer atomic<br />
absorption spectrometers.<br />
PerkinElmer’s System 2 EDLs<br />
Consist of two major components: a dual-channel power supply with<br />
matched dual RF driver assemblies, which allows simultaneous,<br />
independent operation of two EDLs, and the interchangeable lamp<br />
sleeves. The lamp sleeve contains the pre-aligned bulb for the element<br />
of interest. The sleeve has the same exterior dimensions as the<br />
PerkinElmer HCLs, allowing System 2 EDLs to be used in the same<br />
lamp mounts and turrets.<br />
System 2 EDLs are as easy-to-use as an HCL. Just install the lamp, turn it<br />
on, and set the current. Changing lamps requires only seconds because<br />
the pre-aligned bulbs require no additional adjustment.<br />
System 2 EDLs include two coded adapter plugs that allow automatic<br />
spectrometer set-up for those PerkinElmer atomic absorption<br />
spectrometers with automatic lamp code reading capabilities.<br />
To ensure operator safety, a built-in interlock prevents lamp operation if<br />
the lamp is not properly installed.<br />
The PerkinElmer Exclusive WARRANTY*<br />
System 2 Electrodeless Discharge Lamps<br />
1. We warrant that during the first six months or after 500 hours of operation, whichever comes<br />
first, from initial date of shipment, the lamps will meet or exceed the intensity and absorption<br />
specifications to which all new lamps are tested.<br />
2. All our Electrodeless Discharge Lamps are warranted to light and emit the spectra of the<br />
element indicated for two years or 1,000 hours of operation from the date of the shipment,<br />
whichever comes first.<br />
3. If any lamp fails before the expiration of the warranty period, it will be replaced free of charge.<br />
* The lamp warranty is void for lamps that sustain physical damage or are operated at power<br />
levels substantially above or below the power level recommended on the lamp label.<br />
The lamp warranty may vary in different countries.<br />
Electrodeless Discharge Lamps For Greater Brightness<br />
EDLs are typically much brighter and, in some cases,<br />
provide better sensitivity than comparable HCLs. EDLs are<br />
preferred for certain volatile elements. They offer better<br />
precision and lower detection limits for analyses that are<br />
“noisy” due to weak hollow cathode emission. PerkinElmer<br />
System 2 EDLs consist of the element or a salt of the<br />
element sealed in a quartz bulb containing an inert<br />
gas atmosphere. When an RF field of sufficient power is<br />
applied, the inert gas is ionized and the coupled energy<br />
vaporizes the element and excites the atoms inside the bulb,<br />
resulting in the emission of the characteristic spectrum.<br />
Features and Benefits<br />
■ Brightness: EDLs are much brighter and, in some cases, provide better<br />
sensitivity than comparable hollow cathode lamps<br />
■ Precision: EDLs offer lower detection limits and are preferred for<br />
analyses that are “noisy” due to weak hollow cathode emission<br />
■ Long Life: System 2 EDLs are long-lived for exceptional<br />
cost-effectiveness<br />
■ Automation: PerkinElmer coded lamps allow automatic set-up on<br />
systems with automated turret<br />
■ Quality: Carefully selected materials used in the manufacturing of our<br />
lamps avoid spectral interference<br />
■ Testing: Every lamp is thoroughly tested<br />
■ Design: Our design provides you with the low detection limits needed<br />
for your most difficult determinations<br />
■ Warranty: The performance of every PerkinElmer lamp is fully warranted*<br />
46
Lamps for Atomic Absorption<br />
System 2 EDL Lamps<br />
System 2 EDL Lamps and Adapters<br />
AAnalyst<br />
System 2 Coded Intensitron ®<br />
Element Element EDL Adapter<br />
Symbol Name Part No. Each (€) Part No. Each (€)<br />
As Arsenic N3050605 587 N3050860 45<br />
Bi Bismuth N3050611 587 N3050861 45<br />
Cd Cadmium N3050615 587 N3050862 45<br />
Cs Cesium N3050620 587 N3050863 45<br />
Ge* Germanium N3050630 587 N3050864 44<br />
Hg Mercury N3050634 587 N3050865 45<br />
P* Phosphorus N3050655 587 N3050866 45<br />
Pb Lead N3050657 547 N3050867 45<br />
Rb Rubidium N3050664 587 N3050868 45<br />
Sb Antimony N3050670 587 N3050869 45<br />
Se Selenium N3050672 587 N3050870 45<br />
Sn Tin N3050675 587 N3050871 45<br />
Te Tellurium N3050680 587 N3050872 44<br />
Tl Thallium N3050683 587 N3050873 45<br />
Zn Zinc N3050691 587 N3050874 45<br />
* This element requires a Nitrous Oxide-Acetylene flame<br />
Note: System 2 EDLs come with two coding plugs: a coding plug compatible<br />
with the AAnalyst series of instruments and a coding plug compatible with<br />
earlier instruments having coding capability; for example, the Models SIMAA<br />
6100/6000, 5100 (PC), 4110 ZL, 4100 ZL, 4100, 3300, 2100, and 1100(B).<br />
EDL lamps are compatible with all PerkinElmer atomic absorption<br />
spectrometers except the Models 103, 107, 290, 290B, and 280.<br />
System 2 Electrodeless Discharge Lamps<br />
The PerkinElmer Exclusive WARRANTY*<br />
1. We warrant that during the first six months or after 500 hours of operation, whichever comes first, from initial date of shipment, the lamps<br />
will meet or exceed the intensity and absorption specifications to which all new lamps are tested.<br />
2. All our Electrodeless Discharge Lamps are warranted to light and emit the spectra of the element indicated for two years or 1,000 hours<br />
of operation from the initial date of shipment, whichever comes first.<br />
3. If any lamp fails before the expiration of the warranty period, it will be replaced free of charge.<br />
* The lamp warranty is void for lamps that sustain physical damage or are operated at power levels substantially above or below the power level<br />
recommended on the lamp label. The lamp warranty may vary in different countries.<br />
Lamps for Atomic Absorption Atomic Absorption<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
47
Lamps for Atomic Absorption<br />
System 2 EDL Lamp Supplies and Accessories<br />
EDL Accessories<br />
Atomic Absorption Lamps for Atomic Absorption<br />
EDL Driver Assembly<br />
Part No. 03030997<br />
System 2 EDL Power Supply<br />
Part No. 03030952<br />
Driver Assembly Adapter Cable<br />
Allows System 2 EDL drivers<br />
(03030793 and 03030997) to be<br />
used on an AAnalyst 200/400.<br />
Extension Cable<br />
Increases length of cable on the<br />
AAnalyst 600/700/800, SIMAA<br />
6100/6000, and 4110 ZL System 2 EDL<br />
Driver Assembly to the same length as<br />
those on “standard” driver assemblies.<br />
System 2 EDL Modulation Cable<br />
Connects the power supply to the instrument.<br />
(Included with System 2 EDL Power Supply.)<br />
Description Part No. Each (€)<br />
For all instruments (except AAnalyst 100/300) 03030791 185<br />
requiring external EDL modulation<br />
For AAnalyst 100/300 N0410100 153<br />
Included with System 2 Power Supply<br />
EDL Driver Assemblies<br />
EDL Driver Assemblies<br />
Description Part No. Each (€)<br />
For AAnalyst 200/400 N3150131 886<br />
For AAnalyst 600/700/800, SIMAA 4110 ZL 03030997 886<br />
(short cable)<br />
For all models except AAnalyst 600/700/800, 03030793 976<br />
SIMAA 4110 ZL (long cable)<br />
System 2 EDL Power Supply<br />
For use with systems that do not have built-in power<br />
<strong>supplies</strong>. Provides both continuous or modulated operation<br />
of System 2 EDLs. Includes two independently powered<br />
channels with continuously adjustable power output<br />
for each channel, two driver assemblies (03030793),<br />
and modulation cables (03030791 and N0410100).<br />
Description Part No. Each (€)<br />
Power Supply 115 V, 50/60 Hz FCC/VDE approved 03030952 3686<br />
Power Supply 230 V, 50 Hz VDE approved 03030972 3686<br />
Note: EDL System 2 Power Supplies are not<br />
compatible with earlier “System 1” EDLs<br />
Part No.<br />
Each (€)<br />
N3150303 29<br />
Part No.<br />
Each (€)<br />
03030998 74<br />
48
Mercury/Hydride System<br />
MHS-15<br />
Mercury/Hydride Systems are well proven accessories for<br />
high-sensitivity determinations of mercury and metallic<br />
hydride-forming elements, including As, Se, Sb, Te, Bi<br />
and Sn by atomic absorption spectroscopy.<br />
MHS-15 Detection Limits<br />
■<br />
■<br />
■<br />
■<br />
Mercury/Hydride Systems and Supplies<br />
Complete separation of the<br />
element being studied<br />
from its sample matrix<br />
Simple, highly specific<br />
operating procedures<br />
Reliable pneumatic control<br />
of carrier gas and transport<br />
of metallic vapors to the<br />
quartz cell<br />
Conveniently stands<br />
adjacent to the sample<br />
compartment of the<br />
AA spectrometer<br />
Detection Limit* Detection Limit*<br />
Absolute (ng)<br />
Relative (μg/L)<br />
Element (in 10 mL volume) (in 50 mL volume)<br />
As 1.0 0.02<br />
Se 1.0 0.02<br />
Bi 2.0 0.10<br />
Sb 5.0 0.10<br />
Te 2.0 0.05<br />
Hg 1.0 0.02<br />
* EDL lamps were used for all elements.<br />
MHS-15 Mercury/Hydride System<br />
Manually operated system for the high-sensitivity<br />
determination of Hg and hydride-forming elements.<br />
Includes analyzer with sample flask, reagent reservoir,<br />
quartz cell, and cell holder. Switch allows selection of<br />
NaBH 4 or SnCl 2 reductant solution. No electrical<br />
connections are required.<br />
Part No. Each<br />
(€)<br />
B3140760 2439<br />
Quartz Cells<br />
Quartz Cell for MHS-10/15<br />
Part No. B0094415<br />
MHS, Quartz Cells, and Supplies<br />
Quartz Cell for MHS-10 and MHS-15<br />
Complete with graphite cooling<br />
rings and silicone rubber sleeves.<br />
Quartz Cell for MHS-20<br />
Description Part No. Each (€)<br />
With Windows B0097693 1339<br />
Without Windows B0097694 912<br />
Quartz Window for<br />
MHS-20 Quartz Cells<br />
Universal Quartz Cell Holder<br />
To mount MHS-10 or MHS-15 quartz<br />
cell on burner system.<br />
Supplies<br />
For MHS-10/15/20<br />
Quartz Cell for MHS-20<br />
Part No. B0097693<br />
Part No.<br />
Part No.<br />
Each (€)<br />
B3000350 338<br />
Description Part No. Each (€)<br />
Flashback Arrestor B0098640 74<br />
Graphite Cooling Ring for Quartz Cells* B0094413 37<br />
Immersion Tube (Pipette Tip) B0094138 21<br />
Reductant Reservoir (with cap) B0087354 147<br />
Reductant Reservoir (without cap) B0094032 16<br />
Sample Flask** B0094321 38<br />
Silicone Sleeve for Quartz Cells B0098453 1<br />
Transfer Hose B0094140 8<br />
* For MHS-10 and MHS-15 only.<br />
** Specially formed polypropylene reaction vessel with cover.<br />
Each (€)<br />
B0094415 386<br />
Part No.<br />
Each (€)<br />
B0098452 338<br />
Mercury/Hydride Systems and Supplies Atomic Absorption<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
49
Sample Preparation Systems<br />
High Pressure Asher System<br />
Sample Preparation Systems<br />
High Pressure Asher<br />
System Supplies<br />
The Anton Paar HPA-S is a high-performance digestion<br />
system. Using hermetically closed vessels and applying<br />
a maximum temperature of up to 320 °C, the HPA-S<br />
rapidly decomposes even the most complex samples.<br />
The HPA-S provides superior digestion quality.<br />
■ Complete sample mineralization<br />
■ Minimum organic residue<br />
■ No elemental losses<br />
■ No contamination<br />
The HPA-S can be used with a variety of different sized<br />
vessels, making it ideally suited for many different<br />
sample types and analytical applications.<br />
The HPA-S can digest up to 21 samples simultaneously.<br />
The high temperature and pressure is applied in a<br />
hermetically closed system, and the quick and efficient<br />
cooling at the end of the digestion keeps the total<br />
digestion time short.<br />
The samples and reagents are placed in vessels which<br />
are then inserted into the heating block and placed into<br />
the autoclave chamber of the HPA-S. The chamber is then<br />
hermetically closed with a quick-lock lid and pressurized<br />
with nitrogen. Starting at 100 bar (1475 psi), the pressure<br />
rises with increasing temperature up to 130 bar (1920 psi).<br />
This pressure ensures a tight seal during decomposition,<br />
despite the rapidly increasing pressure due to the reaction<br />
process. The system is conventionally heated using a<br />
preselected temperature program.<br />
Atomic Absorption<br />
50
Sample Preparation Systems<br />
High Pressure Asher System Supplies<br />
Heat Trays<br />
Reaction Vessel Racks<br />
Heat trays are heating blocks for insertion of reaction<br />
vessels into the HPA-S pressure chamber.<br />
Heat Tray for 5 Vessels<br />
Aluminum block for insertion of five<br />
quartz digestion vessels — 90 mL.<br />
Heat Tray for 6 Vessels<br />
Aluminum block for insertion of six<br />
(glassy carbon) digestion vessels — 20 mL.<br />
Heat Tray for 7 Vessels<br />
Aluminum block for insertion of seven<br />
quartz digestion vessels — 50 mL.<br />
Heat Tray for 14 Vessels<br />
Aluminum block for insertion of<br />
14 quartz digestion vessels — 15 mL.<br />
Heat Tray for 21 Vessels<br />
Aluminum block for insertion of<br />
21 quartz digestion vessels — 15 mL.<br />
Reaction Vessels and Lids<br />
Part No.<br />
Part No.<br />
Part No.<br />
Each (€)<br />
B0511601 627<br />
Each (€)<br />
B0511523 375<br />
Part No.<br />
Each (€)<br />
B0511602 627<br />
Each (€)<br />
B0511522 604<br />
Part No.<br />
Each (€)<br />
B0511603 710<br />
Reaction Vessel Part No. Each (€) Req.Lid Part No. Each (€)<br />
15 mL Quartz B0511516 76 16 mm B0511517 42<br />
50 mL Quartz B0511514 156 22 mm B0511515 69<br />
90 mL Quartz B0511513 196 22 mm B0511515 69<br />
20 mL Glassy Carbon B0511518 330 B0511519 70<br />
Reaction vessel racks are made of PVC and are<br />
used to hold reaction vessels.<br />
15 mL Reaction Vessel Rack<br />
PVC rack for holding up to 14<br />
15 mL reaction vessels.<br />
20 mL Reaction Vessel Rack<br />
PVC rack for holding up to six 20 mL<br />
glassy carbon reaction vessels.<br />
50 mL Reaction Vessel Rack<br />
PVC rack for holding up to seven<br />
50 mL (or older 30 mL) reaction vessels.<br />
90 mL Reaction Vessel Rack<br />
PVC rack for holding up to five<br />
90 mL reaction vessels.<br />
Reaction Vessel Sets<br />
Reaction vessel sets are complete and include reaction vessels,<br />
lids, heat tray, vessel rack, and PTFE tape for vessel closure.<br />
5 x 90 mL Quartz Reaction Vessel Set<br />
Used for the digestion of five samples<br />
(maximum weight 1.5 g each) in<br />
90 mL quartz vessels.<br />
6 x 20 mL Glassy Carbon Reaction Vessel Set<br />
Used for the digestion of six samples<br />
(maximum weight 0.8 g each) in<br />
20 mL glassy carbon vessels.<br />
7 x 50 mL Quartz Reaction Vessel Set<br />
Used for the digestion of seven samples<br />
(maximum weight 0.8 g each) in<br />
50 mL quartz vessels.<br />
14 x 15 mL Quartz Reaction Vessel Set<br />
Used for the digestion of 14 samples<br />
(maximum weight 0.2 g each) in<br />
15 mL quartz vessels.<br />
Part No.<br />
Part No.<br />
Part No.<br />
Each (€)<br />
B0511526 98<br />
Each (€)<br />
B0511527 98<br />
Part No.<br />
Each (€)<br />
B0511525 98<br />
Each (€)<br />
B0511524 98<br />
Part No.<br />
Part No.<br />
Part No.<br />
Each (€)<br />
B0511502 1980<br />
Each (€)<br />
B0511505 3040<br />
Part No.<br />
Each (€)<br />
B0511503 2380<br />
Each (€)<br />
B0511504 2582<br />
Sample Preparation Systems Atomic Absorption<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
51
Sample Preparation Systems<br />
High Pressure Asher System Supplies<br />
Supplies<br />
Atomic Absorption Sample Preparation Systems<br />
Back-up Ring for O-Ring<br />
Special back-up ring made of<br />
reinforced PTFE compound located<br />
behind O-Ring B0511528.<br />
Extraction Tool<br />
Tool for removing heat trays from<br />
the HPA-S pressure chamber.<br />
O-Ring 107 x 5 FPM with FEP Coating<br />
Special O-Ring for hermetically sealing<br />
the high-pressure chamber safety lid.<br />
PTFE Tape<br />
Rupture Disk, DN 15<br />
Analytically pure PTFE tape for<br />
positioning the lids on the reaction<br />
vessels. The roll is 6.5 m.<br />
Made of corrosion-resistant Inconel ® alloy with a burst<br />
pressure of 180 bar. This allows for overpressure relief in<br />
case of heavy explosions inside the HPA-S. Replace rupture<br />
disk after approximately 750 cycles.<br />
Part No. Each (€)<br />
Support Ring, PEEK<br />
Located behind the back-up ring (B0511529), this support<br />
ring gives mechanical stability<br />
to the entire seal assembly.<br />
Part No. Each (€)<br />
Wrapping Tool for PTFE Tape<br />
Tool for closing the HPA-S vessels<br />
with their lids using PTFE tape by<br />
applying a special wrapping technique.<br />
Part No.<br />
Each (€)<br />
B0511529 20<br />
Part No.<br />
Each (€)<br />
B0511512 310<br />
Part No.<br />
Each (€)<br />
B0511528 56<br />
Part No.<br />
Each (€)<br />
B0511507 17<br />
B0511511 168<br />
B0511530 117<br />
Part No.<br />
Each (€)<br />
B0511506 890<br />
52
Sample Preparation Systems<br />
Multiwave<br />
Multiwave Accessories and Supplies<br />
The Multiwave can be used with a wide variety of reaction vessels allowing the application of optimum reaction conditions<br />
for almost every type of sample. The table below provides an overview of all the available reaction vessel assemblies.<br />
Operation Maximum Maximum Applicable Typical Sample Maximum Filling<br />
Type* Volume Material Pressure Pressure Temperature Rotor Type Weight Volume Part No. Each (€)<br />
HQ20 20 mL Quartz 75 bar 130 bar 300 ºC 6-position 10-200 mg 6 mL<br />
HQ50 50 mL Quartz 75 bar 130 bar 300 ºC 6-position 100-1000 mg 20 mL B0502197 1721<br />
HF50 50 mL TFM 75 bar 130 bar 260 ºC 6-position 50-500 mg 20 mL B0511677 1041<br />
MF100 100 mL TFM (PFA) 30 bar 70 bar 260 ºC 6-position 100-1500 mg 50 mL B0511541 1180<br />
LF100 100 mL PFA 20 bar 70 bar 230 ºC 12-position 100-1000 mg 50 mL B3140380 545<br />
*Type definition: HQ50<br />
HQ20<br />
Characteristics<br />
Small, high temperature vessel for analysis of<br />
micro-samples of a few mg, for ultratrace analysis<br />
Typical Applications<br />
■ Pharmaceuticals<br />
■ Biological and forensic microsamples<br />
■ Biopolymers<br />
HQ50<br />
Characteristics<br />
High temperature vessel for organic material,<br />
for Hg detection, and for ultratrace analysis<br />
Typical Applications<br />
■ Food (high fat)<br />
■ Plastics, Fibers<br />
■ Oil, Grease, Coal<br />
■ Pigments<br />
HF50<br />
Characteristics<br />
For high pressure (HF) applications<br />
of difficult organics and inorganics<br />
Typical Applications<br />
■ Semiconductor<br />
■ Ceramics<br />
■ Oxides<br />
■ Geological material<br />
Volume: 20, 50, 100 mL<br />
Material: Q…Quartz<br />
F…Fluorpolymer (TFM or PFA)<br />
Pressure: H…High<br />
M…Medium<br />
L…Low<br />
Multiwave – shipped prior to January 2002<br />
MF100<br />
Characteristics<br />
Large vessel for versatile applications,<br />
for combined organic-inorganic samples<br />
Typical Applications<br />
■ Soil, sediments<br />
■ Ashes, slags<br />
■ Metals, ores<br />
■ Glass, quartz<br />
LF100<br />
Characteristics<br />
Vessel with high over-pressure tolerance,<br />
for high throughput of “easy” samples<br />
Typical Applications<br />
■ Water, effluent<br />
■ Metals, alloys<br />
■ Plant material<br />
■ Beverages<br />
Sample Preparation Systems Atomic Absorption<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
53
Sample Preparation Systems<br />
Multiwave<br />
Reaction Vessel Assemblies<br />
Atomic Absorption Sample Preparation Systems<br />
Reaction vessel assemblies include a reaction vessel, screw cap and (where appropriate) liner, support vessel,<br />
plug safety disk, base plate, and jacket.<br />
Item Description HQ20 HQ50 HF50 MF100 LF100 Part No. Each (€)<br />
G<br />
A<br />
O<br />
J<br />
N<br />
P<br />
M<br />
Q<br />
D<br />
F<br />
E<br />
L<br />
H<br />
K<br />
I<br />
B<br />
C<br />
R<br />
Quartz vessel Q20 (20 mL) ■ B0511538 549<br />
Quartz vessel Q50EW (50 mL)* ■ B0511674 643<br />
Liner F50 ■ B0511675 152<br />
Liner F100 ■ A B0511532 102<br />
Liner F100-PFA A ■ B0511678 57<br />
Supporting vessel 50 ■ B0511676 230<br />
Supporting vessel 100 ■ B0511533 168<br />
Supporting vessel with thread ■ B3140382 164<br />
Plug ■ ■ ■ ■ B0502201 123<br />
Plug B ■ B0511539 271<br />
Safety Disk H ■ ■ ■ B0502202 13<br />
Safety Disk M ■ ■ B0511535 12<br />
Seal 25, pkg. 6 ■ ■ ■ B0502203 135<br />
Seal 40, pkg. 6 ■ ■ B0511534 139<br />
Vessel base plate ■ ■ ■ B0502204 148<br />
Bomb jacket PEEK ■ ■ ■ ■ N/A<br />
Screw cap PEEK ■ ■ ■ ■ N/A<br />
Screw cap L PEEK ■ B3140383 234<br />
* B0511674 replaces former B0502198, quartz vessel, 50 mL<br />
■ Part of respective pressure vessel type<br />
A – possible alternative item<br />
E<br />
F<br />
G<br />
I<br />
C<br />
B<br />
H<br />
HQ20 High Pressure Quartz<br />
Reaction Vessel Assembly<br />
E<br />
D<br />
A<br />
C<br />
I<br />
H<br />
B<br />
HQ50 Part No. B0502197<br />
High Pressure Quartz<br />
Reaction Vessel Assembly<br />
D<br />
H<br />
O<br />
I<br />
B<br />
C<br />
P<br />
HF50 Part No. B0511677<br />
High Pressure TFM<br />
Reaction Vessel Assembly<br />
E<br />
D<br />
L<br />
K<br />
J<br />
C<br />
MF100 Part No. B0511541<br />
Medium Pressure (PFA or TFM)<br />
Reaction Vessel Assembly<br />
M<br />
B<br />
L<br />
K<br />
D<br />
N<br />
R<br />
Q<br />
LF100 Part No. B3140380<br />
Low Pressure PFA<br />
Reaction Vessel Assembly<br />
54
Sample Preparation Systems<br />
Multiwave<br />
Reaction Vessel Racks<br />
PVC rack for holding up to six reaction vessels.<br />
Description Part No. Each (€)<br />
HQ20 B0511540 154<br />
HQ50 or HF50 B0511546 86<br />
MF100 or LF100 B0511546 86<br />
Rotors and Rotor Assemblies<br />
Reaction<br />
Vessel Type Description Part No. Each (€)<br />
HQ20 Rotor Only B0502196 4017<br />
HF50 Rotor Assembly B0511679 7400<br />
(includes Rotor<br />
and 6 vessels)<br />
Reaction Vessel Assembly B0511677 1041<br />
Rotor Only B0502196 4017<br />
HQ50 Rotor Assembly B0502195 8000<br />
(includes Rotor<br />
and 6 vessels)<br />
Reaction Vessel Assembly B0502197 1721<br />
Rotor Only B0502196 4017<br />
MF100 Rotor Assembly B0511537 9800<br />
(includes Rotor<br />
and 6 vessels)<br />
Reaction Vessel Assembly B0511541 1180<br />
Rotor Only B0502196 4017<br />
LF100 Rotor Assembly B3140386 8600<br />
(includes Rotor,<br />
1sensor vessel, and 11<br />
pressure vessles)<br />
Reaction Vessel Assembly* B3140381 1410<br />
Reaction Vessel Assembly** B3140380 545<br />
Rotor Only B3140387 2656<br />
* Sensor Vessel<br />
** Pressure Vessel<br />
Sample Preparation Systems Atomic Absorption<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
55
Sample Preparation Systems<br />
Multiwave 3000<br />
Atomic Absorption Sample Preparation Systems<br />
Multiwave 3000<br />
The 16-position rotor maximizes productivity.<br />
Rotor 8 for advanced<br />
digestions offers simultaneous<br />
pressure sensing in all vessels.<br />
Multiwave 3000 Accessories<br />
and Supplies<br />
The Multiwave 3000<br />
The Anton Paar Multiwave 3000 is a versatile and powerful<br />
microwave sample preparation system for safe high-pressure<br />
acid digestions of all types of organic and inorganic samples.<br />
The Multiwave 3000 provides dramatically improved sample<br />
capacity, a more powerful dual-magnetron design, superior<br />
sensors requiring no cables and built-in methods. It offers<br />
unique pressure monitoring and a multilevel safety system<br />
that give you the performance and safety you want.<br />
Important user benefits of the Multiwave 3000 are:<br />
■<br />
■<br />
■<br />
■<br />
■<br />
■<br />
■<br />
■<br />
■<br />
■<br />
■<br />
■<br />
Reduced analysis times by fast digestion, using rapid<br />
microwave heating and short cool-down times<br />
Superior digestion quality using closed vessels and<br />
simultaneous high pressure and high temperature<br />
Time-saving, easy operation by simplified method<br />
development and easy, intuitive software<br />
Maximum safety provided by easy handling, sophisticated<br />
sensors, and a library of tested methods<br />
1400 W microwave power ensures fast heating<br />
Unpulsed microwave power from 0 to 1400 W<br />
for precise control of critical reactions<br />
Reliable remote sensors for convenient operation<br />
Fast, built-in cooling system to reduce total cycle time<br />
resulting in improved productivity<br />
Intuitive software for easy routine operation<br />
and documentation<br />
Large PTFE-coated cavity for rough laboratory environments<br />
Proven safety system to minimize hazards from<br />
violent reactions<br />
Modular, industrial-type design offers individual<br />
choice of configurations<br />
Multiwave is a trademark of Anton Paar, GmbH<br />
56
Sample Preparation Systems<br />
Multiwave 3000 Digestion Rotors<br />
Rotor 8 Consumables and Vessels<br />
Pressure Vessel XF100<br />
Complete reaction vessel for various<br />
applications at elevated pressure<br />
and temperature.<br />
Specifications<br />
Part No.<br />
Each (€)<br />
N3142345 960<br />
Volume:<br />
100 mL<br />
Working pressure:<br />
60 bar (870 psi)<br />
Opening pressure:<br />
120 bar (1740 psi)<br />
Max. temperature: 260 °C<br />
Components Part No. Each (€)<br />
1 PEEK Protective Cap N3142353 39<br />
2 Safety Disk Holder X N3142350 27<br />
3 Safety Disk X N3142349 11<br />
4 PEK Seal Holder N3142351 141<br />
5 PEEK Center Ring N3142354 25<br />
6 Syringe Connector N3141022 17<br />
7 Venting Screw N3141021 21<br />
8 PTFE-TFM Seal N3141015 72<br />
9 100 mL TFM liner N3141014 130<br />
10 H100 Ceramics Jacket N3141019 388<br />
11 PEEK Protective Casing N3142352 115<br />
Pressure Vessel XQ80<br />
Complete pressure vessel for<br />
digestions at extreme conditions.<br />
Specifications<br />
Part No.<br />
Each (€)<br />
N3142346 1310<br />
Volume:<br />
80 mL<br />
Working pressure:<br />
80 bar (1160 psi)<br />
Opening pressure:<br />
120 bar (1740 psi)<br />
Max. temperature: 300 °C<br />
Components Part No. Each (€)<br />
1 PEEK Protective Cap N3142353 39<br />
2 Safety Disk Holder X N3142350 27<br />
3 Safety Disk X N3142349 11<br />
4 PEK Seal Holder N3142351 141<br />
5 PEEK Center Ring N3142354 25<br />
6 Syringe Connector N3141022 17<br />
7 Venting Screw N3141021 21<br />
11 PEEK Protective Casing N3142352 115<br />
12 PTFE-TFM Seal XQ N3142348 121<br />
13 Quartz Vessel N3142347 820<br />
XF100<br />
1<br />
2<br />
3<br />
4<br />
5<br />
XQ80<br />
1<br />
2<br />
3<br />
4<br />
5<br />
6<br />
7<br />
8<br />
9<br />
10<br />
11<br />
6<br />
7<br />
12<br />
13<br />
11<br />
Sample Preparation Systems Atomic Absorption<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
57
Sample Preparation Systems<br />
Multiwave 3000 Digestion Rotors<br />
Atomic Absorption Sample Preparation Systems<br />
1<br />
1<br />
2<br />
Immersion Tube<br />
with Seal XF<br />
2<br />
Immersion Tube<br />
with Seal XQ<br />
3<br />
4<br />
6<br />
7<br />
8<br />
3<br />
4<br />
9<br />
7<br />
8<br />
5<br />
5<br />
Rotor 8 Consumables and Vessels<br />
Immersing Temperature Probe T-Probe for Rotor 8<br />
Immersion Tube with Seal XF<br />
Assembly of a special seal holder<br />
with seal for XF100-vessels.<br />
Immersion Tube with Seal XQ<br />
Assembly of a special seal holder<br />
with seal for XQ80-vessels.<br />
Immersing temperature probe<br />
for precise measurement of the<br />
solution temperature in Rotor<br />
8XF100 and XQ80. The sensor<br />
head includes a gas-bulb<br />
thermometer for monitoring<br />
the decomposition<br />
temperature up to 280 °C.<br />
The sensor is hermetically<br />
shielded by a sapphire<br />
thermowell. Its microwavetransparent<br />
design does not<br />
interfere with the microwave<br />
field. The installation is very<br />
easy and does not require any<br />
electrical connections, cables<br />
or hoses. Requires Immersion<br />
Tube with either Seal XQ<br />
(N3142410) or Seal XF<br />
(N3142411).<br />
Part No. Each (€)<br />
N3142409 2190<br />
Part No.<br />
Each (€)<br />
N3142411 980<br />
Part No.<br />
Each (€)<br />
N3142410 980<br />
Components Part No. Each (€)<br />
1 Safety Disk Holder X N3142350 27<br />
2 Safety Disk X N3142349 11<br />
3 Syringe Connector N3141022 17<br />
4 Seal Holder X for T-Probe N3142415 141<br />
5 Venting Screw N3141021 21<br />
6 Seal XF* N3141016 92<br />
7 Husk N3142416 7<br />
8 Immersion Tube Sapphire X N3142413 653<br />
9 Seal XQ for T-Probe N3142412 133<br />
* Also used for Rotor 16 Pressure/Temperature Sensor.<br />
58
Sample Preparation Systems<br />
Multiwave 3000 Digestion Rotors<br />
Rotor 8 Spare Parts<br />
Rotor 8 (without Vessels)<br />
Complete 8 position rotor<br />
without reaction vessels.<br />
Part No.<br />
Each (€)<br />
N3142355 6700<br />
Components Part No. Each (€)<br />
1<br />
2<br />
1<br />
2<br />
3<br />
4<br />
5<br />
6<br />
7<br />
Rotor 8 Lid<br />
Liner Extractor Bolt 8<br />
Rotor Upper Plate (Assembled)<br />
Fastening Screw<br />
Thumbwheel<br />
Insulating Bushing*<br />
Bottom Guard<br />
N3142364<br />
N3142366<br />
N3142356<br />
N3142485<br />
N3142363<br />
N3142486<br />
N3142357<br />
162<br />
68<br />
5000<br />
99<br />
23<br />
18<br />
290<br />
8<br />
9<br />
10<br />
Bottom Load Ring Al Green<br />
Tension Bar Short<br />
Protection Hose 8<br />
N3142431<br />
N3142430<br />
N3142360<br />
1673<br />
140<br />
13<br />
* Used with Black Rotor 8 upper plates shipped prior to July 2005.<br />
1<br />
Rotor 8 for Advanced Digestions<br />
2<br />
9<br />
10<br />
3<br />
7<br />
4<br />
5<br />
6<br />
8<br />
Sample Preparation Systems Atomic Absorption<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
59
Sample Preparation Systems<br />
Multiwave 3000 Digestion Rotors<br />
11<br />
10<br />
Rotor 16 Consumables and Vessels<br />
Sample Preparation Systems<br />
5<br />
Pressure Vessel MF100<br />
(N3141011) respectively<br />
HF100 (N3141012)<br />
3<br />
8<br />
1<br />
6 7<br />
9<br />
Pressure Vessel MF100 MW3000<br />
Complete reaction vessel for routine<br />
and quality control applications.<br />
Specifications<br />
Volume:<br />
100 mL<br />
Working pressure:<br />
20 bar (290 psi)<br />
Opening pressure:<br />
70 bar (1000 psi)<br />
Max. temperature: 200 °C<br />
Pressure Vessel HF100 MW3000<br />
Complete reaction vessel for<br />
versatile applications.<br />
Specifications<br />
Part No.<br />
Volume:<br />
100 mL<br />
Working pressure:<br />
40 bar (580 psi)<br />
Opening pressure:<br />
70 bar (1000 psi)<br />
Max. temperature: 240 °C<br />
Each (€)<br />
N3141011 386<br />
Part No.<br />
Each (€)<br />
N3141012 660<br />
11<br />
5<br />
12<br />
10<br />
14<br />
13<br />
4<br />
9<br />
Components Part No. Each (€)<br />
1 100 mL TFM Liner N3141014 130<br />
6 M100 PEEK Vessel Jacket N3141018 92<br />
3 PTFE-TFM Seal N3141015 72<br />
5 Safety Disk N3141017 8<br />
8 PEK Screw Cap N3141020 143<br />
7 H100 Ceramics Jacket N3141019 388<br />
9 Venting Screw N3141021 21<br />
Package of 16 Venting Screws N3142452 220<br />
10 Syringe Connector N3141022 17<br />
11 Safety Disk Holder M&H N3141023 25<br />
Pressure/Temperature Sensor Accessory<br />
for Rotor 16<br />
Pressure/Temperature<br />
Sensor Accessory<br />
15<br />
Sensor screw cap for simultaneous<br />
pressure and internal temperature<br />
measurement of one MF or HF vessel.<br />
Part No.<br />
Each (€)<br />
N3141005 3340<br />
Pressure Sensor Accessory for Rotor 16<br />
Atomic Absorption<br />
11<br />
Pressure Sensor<br />
Accessory<br />
5<br />
10<br />
14<br />
13<br />
3<br />
9<br />
Sensor screw cap for pressure<br />
measurement of one MF or HF vessel.<br />
Part No.<br />
Each (€)<br />
N3142418 2200<br />
Components Part No. Each (€)<br />
4 Seal p/T Sensor N3141016 92<br />
12 Immersion Tube Sapphire M&H N3142013 680<br />
13 O-Ring 38x1.5 FPM N3142400 2<br />
14 Seal Holder for p/T Sensor N3142399 153<br />
15 Husk N3142416 7<br />
Husk Assembly Tool N3142456 2<br />
60
Sample Preparation Systems<br />
Multiwave 3000 Digestion Rotors<br />
Rotor 16 Spare Parts<br />
Rotor 16 (without Vessels)<br />
Complete 16-position rotor without<br />
reaction vessels and sensors.<br />
1<br />
2<br />
3<br />
4<br />
5<br />
6<br />
7<br />
8<br />
Part No.<br />
Each (€)<br />
N3141025 1180<br />
Components Part No. Each (€)<br />
Rotor 16 Body N3141026 100<br />
Rotor 16 Lid N3141027 72<br />
Rotor 16 Tray N3141028 139<br />
Rotor Base Ring N3141029 158<br />
Vessel Holder N3141030 45<br />
Seal for Vessel Holder N3141031 17<br />
Cheese Head Screw N3142398 2<br />
Liner Extractor Bolt N3141032 68<br />
Rotor 16 for routine digestions<br />
Spare Parts for the Rotor 16<br />
Rotor 16<br />
2<br />
1<br />
4<br />
7<br />
2<br />
3<br />
8<br />
5<br />
6<br />
1<br />
Sample Preparation Systems Atomic Absorption<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
61
Sample Preparation Systems<br />
Multiwave 3000 Drying and Evaporation Rotors<br />
Rotor 1 DRY Supplies<br />
Atomic Absorption Sample Preparation Systems<br />
1<br />
4<br />
Rotor 8 EVAP Supplies<br />
1 3<br />
9<br />
10<br />
11<br />
12<br />
2<br />
3<br />
2 4<br />
5<br />
6<br />
7<br />
8<br />
13<br />
14<br />
1<br />
2<br />
3<br />
4<br />
1<br />
2<br />
3<br />
4<br />
5<br />
6<br />
7<br />
8<br />
9<br />
10<br />
11<br />
12<br />
13<br />
14<br />
Components Part No. Each (€)<br />
Filter Disk Borosilicate Glass N3142000 9<br />
D=30 Porosity 0<br />
Glass Tube N3142001 274<br />
Desiccator Plate N3142002 102<br />
O-Ring N3142003 2<br />
28.24 x 2.62 Silicone<br />
Components Part No. Each (€)<br />
Hose Connector 8/8 N3142370 131<br />
Connection Hose N3142367 29<br />
Hose Connector Nut N3142371 80<br />
Syringe Filter N3142374 8<br />
Screw Cap EVAP N3142373 96<br />
Seal EVAP N3142372 66<br />
Vessel Holder N3141030 45<br />
Seal for Vessel Holder N3141031 17<br />
Liner Extractor Bolt 16 N3141032 68<br />
Rotor Tray EVAP N3142369 133<br />
Rotor 16 Body N3141026 100<br />
Rotor Base Ring N3141029 158<br />
Cheese Head Screw N3142398 2<br />
Ring Weight N3142368 39<br />
62
Sample Preparation Systems<br />
Multiwave 3000 Solvent Extraction Rotors<br />
Rotor 8 SOLV Consumables<br />
and Vessels<br />
Pressure/Temperature Sensor Accessory SOLV<br />
Sensor screw cap for simultaneous<br />
pressure and temperature measurement<br />
in Pressure Vessels SOLV100.<br />
Specifications<br />
Temperature range: 0-300 °C<br />
Pressure range:<br />
0-86 bar (1250 psi)<br />
1<br />
2<br />
3<br />
4<br />
5<br />
6<br />
7<br />
1<br />
2<br />
3<br />
4<br />
5<br />
6<br />
7<br />
Components Part No. Each (€)<br />
Immersion Tube Sapphire M&H N3142013 680<br />
Seal Holder N3142429 153<br />
for p/T Sensor Accessory SOLV<br />
Safety Disk SOLV N3142427 13<br />
Hose Connector SOLV N3142437 36<br />
Screw PEEK N3142436 3<br />
Seal p/T SOLV N3142425 102<br />
Husk N3142416 7<br />
Pressure/Temperature Sensor Adapter<br />
Used to convert Pressure Temperature Accessory<br />
(N3141005) which is used for acid digestion into a sensor<br />
for solvent extraction.<br />
Specifications<br />
Working pressure:<br />
Opening pressure:<br />
8<br />
18 bar (252 psi)<br />
22 bar (300 psi)<br />
Components Part No. Each (€)<br />
Adapter SOLV N3142420 250<br />
Pressure Vessel SOLV100<br />
Complete reaction vessel for solvent<br />
extraction applications.<br />
Specifications<br />
Part No.<br />
Working pressure:<br />
18 bar (261 psi)<br />
Opening pressure:<br />
22 bar (319 psi)<br />
Max. temperature: 200°<br />
Each (€)<br />
N3142419 3590<br />
Part No.<br />
Each (€)<br />
N3142423 390<br />
Components Part No. Each (€)<br />
PEEK Screw N3142436 3<br />
Hose Connector N3142437 36<br />
Safety Disk N3142427 13<br />
PEK Screw Cap N3142428 143<br />
Seal SOLV N3142424 82<br />
Liner F100TFM N3141014 130<br />
Vessel Jacket M100 PEEK N3141018 92<br />
1<br />
2<br />
3<br />
4<br />
7<br />
8<br />
{<br />
7<br />
1<br />
5<br />
6<br />
4<br />
5<br />
3<br />
6<br />
2<br />
Sample Preparation Systems Atomic Absorption<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
63
Sample Preparation Systems<br />
Multiwave 3000 Solvent Extraction Rotors and System Spare Parts<br />
Rotor 8 SOLV Spare Parts<br />
Atomic Absorption Sample Preparation Systems<br />
Seal Forming Device<br />
For Rotor XQ80<br />
For Rotor MF100,<br />
HF100, XF100<br />
1<br />
2<br />
3<br />
4<br />
5<br />
6<br />
7<br />
1<br />
2<br />
3<br />
4<br />
5<br />
6<br />
7<br />
System Spare Parts<br />
Exhaust Silencer<br />
Seal Forming Device for<br />
8 Caps<br />
Keyboard USA<br />
Quartz Lifting Hook<br />
Quartz Weighing Scoop<br />
Rack 16<br />
Components Part No. Each (€)<br />
Rotor 16 Lid N3141027 72<br />
Level Indicator N3142438 33<br />
Liner Extractor Bolt 16 N3141032 68<br />
Rotor Tray 8SOLV N3142435 150<br />
Vessel Holder N3141030 45<br />
Seal for Vessel Holder N3141031 17<br />
Rotor 16 Body N3141026 100<br />
Sound Insulator Hood<br />
Part No.<br />
Each (€)<br />
N3142453 360<br />
Part No.<br />
Each (€)<br />
N3141009 310<br />
Part No.<br />
Each (€)<br />
N3141010 170<br />
Part No.<br />
Each (€)<br />
N3142451 78<br />
Part No.<br />
Each (€)<br />
N3142450 96<br />
Part No.<br />
Each (€)<br />
N3142449 98<br />
Part No.<br />
Each (€)<br />
N3142454 98<br />
64
Standards<br />
PerkinElmer Pure Atomic Spectroscopy Standards<br />
Whatever your application,<br />
you can depend on PerkinElmer Pure<br />
standards to yield reliable, accurate results.<br />
PerkinElmer offers a wide selection of atomic absorption<br />
calibration standards. Each solution is supplied with a<br />
comprehensive Certificate of Analysis that documents the<br />
quality. To ensure that your measurements are accurate, you<br />
can rely on our certificates to provide complete information.<br />
Quality<br />
PerkinElmer Pure standards are prepared gravimetrically<br />
from high-purity metals and salts, using high-purity reagents.<br />
■ ASTM Type I, filtered water minimizes cations, anions, and colloids;<br />
resistivity is maintained in the 18-megohm range.<br />
■ Acids used are the highest purity.<br />
■ Semi-micro analytical balances and Class A volumetric<br />
glassware are used, and the bottles are subjected to a stringent<br />
leaching/cleaning process.<br />
■ Following preparation, standards are analyzed for the major element<br />
as well as trace impurities. The results of the analysis are provided<br />
on the Certificate of Analysis.<br />
Reliability<br />
Single-element standards are<br />
measured by three methods:<br />
1. DC arc analysis of starting materials for<br />
trace impurities (semi-quantitative).<br />
2. Gravimetric, “wet” assay for<br />
major constituents.<br />
3. ICP check of the final solution.<br />
The results of these three<br />
analyses are reported on<br />
the Certificate of Analysis.<br />
NIST or NBS SRMs used for the ICP check<br />
are also reported on the Certificate of Analysis.<br />
Safety<br />
We ship standards to comply with both DOT and<br />
IATA regulations to ensure their safe delivery to you.<br />
PerkinElmer Pure Atomic<br />
Spectroscopy Standards are<br />
manufactured for PerkinElmer<br />
to the highest quality standards.<br />
Features<br />
■ ISO 9001 accredited by Underwriters Laboratories including<br />
comprehensive continuous improvement, product recall, corrective action<br />
request, and other quality maintenance and improvement programs<br />
■ Accreditation by NVLAP/NIST as an EPA performance testing provider<br />
■ Product labeling meets OSHA and California labeling standards<br />
■ Bottles are low-density polyethylene from industry standard Nalge<br />
Corporation and are pre-leached and pre-treated for increased product<br />
stability and purity<br />
■ High-purity acids and ASTM Type I water used in all manufacturing,<br />
as reported on the Certificate of Analysis<br />
■ Traceability directly to NIST standard reference materials, not independent<br />
sources or secondary NIST SRMs and reported on the Certificate of Analysis<br />
■ Wet assays on all single-element products via standard, accepted wet<br />
methods and traceable directly to NIST SRM to +/-0.5% of true value<br />
and reported on the Certificate of Analysis<br />
■ All solutions tested and confirmed for the absence of interfering anions,<br />
e.g. chloride, bromide, etc.<br />
■ Twelve months guaranteed stability +/-0.5% for all major analytes<br />
for all products<br />
65
Standards<br />
PerkinElmer Pure Atomic Absorption Standards<br />
Atomic Absorption Standards<br />
Alternate Trace Metal Drinking<br />
Pollution and Wastewater Standards<br />
Alternate Metals I<br />
Matrix/Vol. Concentration of Element Part No. Each (€)<br />
2% HNO 3 /100 mL 20 μg/mL Aluminum N9300214 190<br />
5 μg/mL Antimony<br />
5 μg/mL Beryllium<br />
10 μg/mL Cobalt<br />
10 μg/mL Copper<br />
20 μg/mL Iron<br />
10 μg/mL Manganese<br />
10 μg/mL Nickel<br />
5 μg/mL Thallium<br />
20 μg/mL Vanadium<br />
10 μg/mL Zinc<br />
Alternate Metals II<br />
Matrix/Vol. Concentration of Element Part No. Each (€)<br />
2% HNO 3 /100 mL 500 μg/mL Calcium N9300215 114<br />
100 μg/mL Magnesium<br />
100 μg/mL Potassium<br />
500 μg/mL Sodium<br />
GFAAS Mixed Standard<br />
Matrix/Vol. Concentration of Element Part No. Each (€)<br />
5% HNO 3 100 μg/mL Aluminum N9300244 228<br />
w/trace of HF/100 mL 100 μg/mL Antimony<br />
100 μg/mL Arsenic<br />
50 μg/mL Barium<br />
5 μg/mL Beryllium<br />
5 μg/mL Cadmium<br />
20 μg/mL Chromium<br />
50 μg/mL Cobalt<br />
50 μg/mL Copper<br />
20 μg/mL Iron<br />
100 μg/mL Lead<br />
20 μg/mL Manganese<br />
50 μg/mL Nickel<br />
100 μg/mL Selenium<br />
10 μg/mL Silver<br />
100 μg/mL Thallium<br />
CLP Standards<br />
Instrument Calibration Standards<br />
All the solutions you need for daily calibration of your ICP<br />
and HGA ® for CLP analyses<br />
Remember to prepare your calibration standards fresh for<br />
each analysis and discard after use<br />
Dilute with high-purity 5% HNO 3<br />
Instrument Calibration Standard 1<br />
Matrix/Vol. Concentration of Element Part No. Each (€)<br />
5% HNO 3 /100 mL 5,000 μg/mL Calcium N9300218 190<br />
5,000 μg/mL Magnesium<br />
5,000 μg/mL Potassium<br />
5,000 μg/mL Sodium<br />
Instrument Calibration Standard 2<br />
Matrix/Vol. Concentration of Element Part No. Each (€)<br />
5% HNO 3 /100 mL 100 μg/mL Chromium N9300219 126<br />
150 μg/mL Manganese<br />
400 μg/mL Nickel<br />
100 μg/mL Silver<br />
200 μg/mL Sodium<br />
Instrument Calibration Standard 3<br />
Matrix/Vol. Concentration of Element Part No. Each (€)<br />
5% HNO 3 /100 mL 2,000 μg/mL Aluminum N9300220 165<br />
2,000 μg/mL Barium<br />
50 μg/mL Beryllium<br />
500 μg/mL Cobalt<br />
250 μg/mL Copper<br />
1,000 μg/mL Iron<br />
500 μg/mL Vanadium<br />
Instrument Calibration Standard 4<br />
Matrix/Vol. Concentration of Element Part No. Each (€)<br />
5% HNO 3 /100 mL 100 μg/mL Arsenic N9300221 114<br />
50 μg/mL Cadmium<br />
50 μg/mL Lead<br />
50 μg/mL Selenium<br />
100 μg/mL Titanium<br />
Instrument Calibration Standard 5<br />
Matrix/Vol. Concentration of Element Part No. Each (€)<br />
2% HNO 3 /500 mL 1,000 μg/mL Antimony N9300101 101<br />
Instrument Calibration Standard 6<br />
Matrix/Vol. Concentration of Element Part No. Each (€)<br />
10% HNO 3 /500 mL 1,000 μg/mL Mercury N9300133 101<br />
66
Standards<br />
PerkinElmer Pure Atomic Absorption Standards<br />
Contract Required Detection Limits<br />
(CRDL) Standard<br />
Used for Initial Calibration Verification (ICV). Contains all the elements on<br />
the Inorganic Target Analyte List (TAL) in one solution. Select only those<br />
elements for verification that you will subsequently determine. Dilute<br />
10-fold prior to use for ICP analysis. Dilute 500-fold prior to use for<br />
graphite furnace analysis.<br />
Initial Calibration Verification Standard<br />
Matrix/Vol. Concentration of Element Part No. Each (€)<br />
5% HNO 3 /500 mL 200 μg/mL Aluminum N9300224 738<br />
60 μg/mL Antimony<br />
10 μg/mL Arsenic<br />
200 μg/mL Barium<br />
5 μg/mL Cadmium<br />
500 μg/mL Calcium<br />
10 μg/mL Chromium<br />
50 μg/mL Cobalt<br />
25 μg/mL Copper<br />
100 μg/mL Iron<br />
3 μg/mL Lead<br />
500 μg/mL Magnesium<br />
15 μg/mL Manganese<br />
40 μg/mL Nickel<br />
500 μg/mL Potassium<br />
5 μg/mL Selenium<br />
10 μg/mL Silver<br />
500 μg/mL Sodium<br />
10 μg/mL Thallium<br />
50 μg/mL Vanadium<br />
20 μg/mL Zinc<br />
AA Test Mix. Recommended for use in checking sensitivity for eight<br />
elements commonly determined by Flame AA.<br />
Contract Required Detection Limits (CRDL) Standard<br />
Matrix/Vol. Concentration of Element Part No. Each (€)<br />
2% HCL/100 mL 50 μg/mL Calcium 02900540 126<br />
50 μg/mL Chromium<br />
50 μg/mL Copper<br />
50 μg/mL Iron<br />
50 μg/mL Nickel<br />
20 μg/mL Potassium<br />
10 μg/mL Sodium<br />
10 μg/mL Zinc<br />
Groundwater and Wastewater<br />
Pollution Control Check Standards<br />
Use as a daily control standard<br />
Check the accuracy and precision of your analysis<br />
Refer to U.S. EPA methods manual 600/4-79-020, “Methods for Chemical<br />
Analysis of Water and Wastes”: Trace metals I, II, and III methods.<br />
Trace Metals I<br />
Matrix/Vol. Concentration of Element Part No. Each (€)<br />
5% HNO 3 /100 mL 500 μg/mL Aluminum N9300211 228<br />
100 μg/mL Arsenic<br />
100 μg/mL Beryllium<br />
25 μg/mL Cadmium<br />
100 μg/mL Chromium<br />
100 μg/mL Cobalt<br />
100 μg/mL Copper<br />
100 μg/mL Iron<br />
100 μg/mL Lead<br />
100 μg/mL Manganese<br />
5 μg/mL Mercury<br />
100 μg/mL Nickel<br />
25 μg/mL Selenium<br />
250 μg/mL Vanadium<br />
100 μg/mL Zinc<br />
Trace Metals II<br />
Matrix/Vol. Concentration of Element Part No. Each (€)<br />
2% HNO 3 /100 mL 20 μg/mL Antimony N9300212 88<br />
10 μg/mL Silver<br />
20 μg/mL Thallium<br />
Trace Metals III<br />
Matrix/Vol. Concentration of Element Part No. Each (€)<br />
2% HNO 3 /100 mL 500 μg/mL Barium N9300213 152<br />
500 μg/mL Calcium<br />
100 μg/mL Magnesium<br />
500 μg/mL Molybdenum<br />
100 μg/mL Potassium<br />
500 μg/mL Sodium<br />
Reagents<br />
Antifoaming Silicone Emulsion B0507226 91<br />
Dow Corning DB 110 A, 500 mL. Controls foaming during<br />
reaction when using the MHS-10, MHS-15, or MHS-20.<br />
Triton X-100 Wetting Agent N9300260 24<br />
Glycerol B3141064 29<br />
Matrix Modifiers for Graphite Furnace AA<br />
Modifier Concentration Volume Part No. Each (€)<br />
Mg(NO 3 ) 2 1% Mg (as nitrate) 100 B0190634 71<br />
Pd 10% Pd (as nitrate) 50 B0190635 249<br />
NH 4 H 2 PO 4 10% NH 4 H 2 PO 4 100 N9303445 101<br />
High-purity compounds minimize the risk of contamination<br />
Optimum graphite furnace program can be used due to<br />
reduced analyte volatility<br />
Convenient, ready-to-use<br />
Standards Atomic Absorption<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
67
Standards<br />
PerkinElmer Pure Atomic Absorption Standards<br />
Single-Element Calibration Standards<br />
The single-element standards listed have a concentration of 1,000 μg/mL in aqueous solution. All<br />
are available in volumes of 500 mL, while selected standards are also available in 100 mL volumes.<br />
Atomic Absorption Standards<br />
Starting 500 mL 100 mL<br />
Element Symbol Matrix Material Part No. Each (€) Part No. Each (€)<br />
Aluminum Al 2% HNO 3 Al(NO 3 ) 3<br />
•9H 2 O N9300100 101 N9300184 50<br />
Antimony Sb 2% HNO 3 Sb 2 O 3 N9300101 101 N9300207 50<br />
Arsenic As 2% HNO 3 H 3 AsO 4<br />
• 1⁄2 H 2 0 N9300102 101 N9300180 50<br />
Barium Ba 2% HNO 3 BaCO 3 N9300103 101 N9300181 50<br />
Beryllium Be 2% HNO 3 Be 4 O(C 2 H 3 O 2 ) 6 N9300104 101 N9300172 50<br />
Bismuth Bi 10% HNO 3 Bi N9300105 101 N9303761 50<br />
Boron B H 2 O (NH 4 ) 2 B 4 O 7<br />
•4H 2 O N9300106 101<br />
Cadmium Cd 2% HNO 3 Cd N9300107 101 N9300176 50<br />
Calcium Ca 2% HNO 3 CaCO 3 N9300108 101 N9303763 50<br />
Cerium Ce 2% HNO 3 Ce(NO 3 ) 3<br />
•6H 2 O N9300110 101<br />
Cesium Cs 2% HNO 3 CsNO 3 N9300111 114<br />
Chromium Cr 2% HNO 3 Cr(NO 3 ) 3<br />
•9H 2 O N9300112 101 N9300173 50<br />
Cobalt Co 2% HNO 3 CoCO 3 N9300113 101 N9303766 50<br />
Copper Cu 2% HNO 3 Cu N9300114 101 N9300183 50<br />
Dysprosium Dy 2% HNO 3 Dy 2 O 3 N9300115 114<br />
Erbium Er 2% HNO 3 Er 2 O 3 N9300116 114<br />
Europium Eu 2% HNO 3 Eu 2 O 3 N9300117 114<br />
Gadolinium Gd 2% HNO 3 Gd 2 O 3 N9300118 114<br />
Gallium Ga 2% HNO 3 Ga N9300119 114<br />
Germanium Ge H 2 O (NH 4 ) 2 Ge(C 2 O 4 ) 3<br />
•XH 2 O N9300120 114<br />
Gold Au 10% HCl Au N9300121 228 N9303759 126<br />
Hafnium Hf 2% HCl HfOCl 2<br />
•8H 2 O N9300122 114 N9303775 50<br />
Holmium Ho 2% HNO 3 Ho 2 O 3 N9300123 114<br />
Indium In 2% HNO 3 In N9300124 114<br />
Iridium Ir 10% HCl IrCl 3<br />
•3H 2 O N9300125 228<br />
Iron Fe 2% HNO 3 Fe N9300126 101 N9303771 50<br />
Lanthanum La 2% HNO 3 La 2 O 3 N9300127 101<br />
Lead Pb 2% HNO 3 Pb N9300128 101 N9300175 50<br />
Lithium Li 2% HNO 3 Li 2 CO 3 N9300129 101<br />
Lutetium Lu 2% HNO 3 Lu 2 O 3 N9300130 381<br />
Magnesium Mg 2% HNO 3 Mg N9300131 101 N9300179 50<br />
Manganese Mn 2% HNO 3 Mn(C 2 H 3 O 2 ) 3<br />
•2H 2 O N9300132 101 N9303783 50<br />
Mercury* Hg 10% HNO 3 Hg N9300133 101 N9300174 50<br />
* Also available at 10 μg/mL as Part No. N9300253.<br />
68
Standards<br />
PerkinElmer Pure Atomic Absorption Standards<br />
Starting 500 mL 100 mL<br />
Element Symbol Matrix Material Part No. Each (€) Part No. Each (€)<br />
Molybdenum Mo H 2 O (NH 4 )6Mo 7 O 24<br />
•4H 2 O N9300134 101 N9303784 50<br />
Neodymium Nd 2% HNO 3 Nd 2 O 3 N9300135 114<br />
Nickel Ni 2% HNO 3 Ni N9300136 101 N9300177 50<br />
Niobium Nb H 2 O NH 4 NbF6 N9300137 114<br />
Palladium Pd 10% HCl (NH 4 ) 2 PdCl 4 N9300138 228 N9303789 126<br />
Phosphorus P H 2 O NH 4 H 2 PO 4 N9300139 101 N9303788 50<br />
Platinum Pt 10% HCl H2PtCl6•XH 2 O N9300140 228<br />
Potassium K 2% HNO 3 KNO 3 N9300141 101 N9303779 50<br />
Praseodymium Pr 2% HNO 3 Pr 6 O 11 N9300142 114<br />
Rhenium Re H 2 O (NH 4 )2ReO 4 N9300143 228<br />
Rhodium Rh 10% HCl RhCl3•3H 2 O N9300144 381<br />
Rubidium Rb 2% HNO 3 RbNO 3 N9300145 101<br />
Ruthenium Ru 10% HCl RuCl 3<br />
•3H 2 O N9300146 228<br />
Samarium Sm 2% HNO 3 Sm 2 O 3 N9300147 114<br />
Scandium Sc 2% HNO 3 Sc 2 O 3 N9300148 228<br />
Selenium Se 2% HNO 3 Se N9300149 101 N9300182 50<br />
Silicon Si H 2 O (NH 4 )2SiF 6 N9300150 114 N9303799 50<br />
Silver Ag 2% HNO 3 Ag N9300151 101 N9300171 50<br />
Sodium Na 2% HNO 3 Na 2 CO 3 N9300152 101 N9303785 50<br />
Strontium Sr 2% HNO 3 Sr(NO 3 ) 2 N9300153 101<br />
Sulfur S H 2 O (NH 4 ) 2 SO 4 N9300154 101<br />
Tantalum Ta H 2 O NH 4 TaF 6 N9300155 114<br />
Tellurium Te 5% HNO 3 Te N9300156 114<br />
Terbium Tb 2% HNO 3 Tb 4 O 7 N9300157 114<br />
Thallium Tl 2% HNO 3 TlNO 3 N9300158 101 N9300170 50<br />
Thulium Tm 2% HNO 3 Tm 2 O 3 N9300160 152<br />
Tin Sn 20% HCl Sn N9300161 152 N9303801 89<br />
Titanium Ti H 2 O (NH 4 ) 2 TiF 6 N9300162 114 N9303806 50<br />
Tungsten W H 3 O (NH 4 ) 2 WO 4 N9300163 114<br />
Vanadium V 2% HNO 3 NH 4 VO 3 N9300165 101<br />
Ytterbium Yb 2% HNO 3 Yb 2 O 3 N9300166 114<br />
Yttrium Y 2% HNO 3 Y 2 O 3 N9300167 114 N9303810 50<br />
Zinc Zn 2% HNO 3 Zn N9300168 101 N9300178 50<br />
Zirconium Zr 2% HNO 3 ZrO(NO 3 ) 2 N9300169 114 N9303812 50<br />
Standards Atomic Absorption<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
69
WinLab32 Software for AA<br />
Software for Atomic Absorption<br />
WinLab32 Software for AA<br />
Combines Ease of<br />
Use and Flexibility to<br />
Improve Productivity<br />
WinLab32 for AA redefines the software<br />
standard for high-performance atomic<br />
absorption instruments. Designed for<br />
the rigorous needs of today’s analytical<br />
laboratory, WinLab32 gives you all the<br />
flexibility and power you need in an easyto-use,<br />
easy-to-learn package. WinLab32<br />
for AA software provides you with tools and<br />
features needed to quickly start running<br />
samples your way. Only WinLab32 for AA<br />
combines flexibility and ease of use to bring<br />
a new level of productivity to your laboratory.<br />
A suite of task-oriented windows can be displayed.<br />
Key Features:<br />
■ Common look and feel with WinLab32 for ICP for<br />
easy cross-platform use<br />
■ Flexibility for the most demanding needs<br />
■ Extensive QC options ensure data quality<br />
■ Wizards, Multi-language Tool Tips and Tip of<br />
the Day make WinLab32 for AA easy to learn,<br />
easy to use<br />
■ Data Export allows selected data results to be<br />
transfered to a network computer<br />
■ Powerful Examine Transient Peaks accelerates<br />
method development<br />
■ Check sums and Windows ® 2000 security ensure<br />
integrity for regulatory requirements<br />
Easy to Learn and Use — By Design<br />
WinLab32 for AA was not simply<br />
designed by PerkinElmer’s team of<br />
applications experts, programmers and<br />
graphic designers, it was designed by<br />
laboratory managers and AA users from<br />
around the world. The result is software<br />
that you have to see in operation to fully<br />
appreciate just how easy it is to learn and<br />
use. A few of the highlights that make<br />
WinLab32 easy to learn and use include:<br />
■ Wizards<br />
■ Extensive checking<br />
■ Tip of the Day<br />
■ Tool Tips<br />
■ Status panels<br />
■ Automated shutdown<br />
■ Analysis List<br />
■ Context-sensitive Help<br />
Data Reprocessing allows you to change parameters<br />
and recalculate results.<br />
70
WinLab32 Software for AA<br />
Software for Atomic Absorption Analysis<br />
Maximize Productivity<br />
In addition to the numerous ease-of-use characteristics,<br />
WinLab32 has the features you need to enhance productivity<br />
in your laboratory.<br />
■ WinLab32 Offline allows you to create methods, enter sample information,<br />
review or reprocess data — all without interrupting the active analysis<br />
■ Recall Calibration or Initial Calibration Options in the Method Editor<br />
can be used to manually or automatically recall a calibration previously<br />
stored with the method, eliminating the need to reconstruct the curve<br />
prior to sample analysis<br />
■ Edit Calibration gives you complete control over the quality of your<br />
calibration curve before you proceed with QC and sample analysis<br />
■ Data Reprocessing allows you to change many method and sample<br />
information parameters after you have collected the data and to recalculate<br />
the results to determine if the changes are appropriate for your samples<br />
■ Priority Sample and Append to Analysis List allows you to add<br />
samples anytime without interrupting the current analysis<br />
Helping to Meet Regulated Laboratory Requirements<br />
Many laboratories must comply with a variety of regulations<br />
imposed upon them by government agencies or quality<br />
protocols. WinLab32 contains a number of features needed<br />
to help your laboratory meet the regulations, including<br />
21 CFR Part II.<br />
WinLab32 Makes it Easy to Work with Data<br />
Once you have performed analyses, you should be free to<br />
report, change, send, archive, move, or export your data in<br />
any way you wish without following someone else’s rigid<br />
protocols. WinLab32 provides a number of tools to help you<br />
work with your data.<br />
■ Data Reporting Wizard<br />
■ Data Export Wizard<br />
■ Archive and restore functions<br />
■ Maintenance functions<br />
WinLab32 includes a variety of ways to export data,<br />
including parameters such as peak profiles, sample<br />
concentrations, etc.<br />
Worldwide Support<br />
WinLab32 for AA is backed by the largest worldwide<br />
technical support network in the industry — just what<br />
you would expect from the leader in analytical<br />
instrumentation for more than 40 years.<br />
Description Part No. Each (€)<br />
WinLab32 Controller Assembly for AA N1010202 4787<br />
Includes computer, 17" flat panel monitor, and<br />
Software Assembly. Contact us for current<br />
models and specifications<br />
WinLab32 Software Assembly for AA N1010200 3059<br />
Includes CD, printer cable, and an IEEE-488<br />
computer interface<br />
WinLab32 Enhanced Security Software Add-on for AA N1010230 3035<br />
Requires WinLab32 Controller or Software Assembly<br />
Wizards make complex tasks easy.<br />
Data Reporting Wizard allows you to report your data<br />
in a variety of formats.<br />
www.perkinelmer.com/<strong>supplies</strong><br />
71
Just touch<br />
and go.<br />
There, that’s all the training you need.<br />
Walk up to the AAnalyst 200 and let the touch screen guide you through everything<br />
from setup to analysis. It practically tells you what to do—and in your own<br />
language. All instrument controls are right there on the screen, available at your<br />
fingertips. Even troubleshooting and repairs are easier, with quick-change parts<br />
you simply snap out and snap in. No service visit, no down time. As rugged and<br />
reliable as ever, our newest AAnalyst is a better way to do AA. Experience it for<br />
yourself. Talk to a PerkinElmer inorganic analysis specialist today.<br />
© 2005 PerkinElmer, Inc. 400012A<br />
800-762-4000 (U.S. and Canada)<br />
(+1) 203-925-4602<br />
www.perkinelmer.com
Elemental Analysis<br />
For over 35 years, PerkinElmer has been a leader in organic<br />
elemental analysis, providing customers with reliable instrumentation<br />
that is easy to use and delivers fast, accurate results.<br />
The PerkinElmer 2400 Series II Elemental Analyzers<br />
supply speed, precision, ease of use and proven<br />
performance to your lab, and are based on the<br />
classical organic analysis techniques of Pregl and<br />
Dumas. Flexibility is a key feature of the 2400 Series II,<br />
offering you multiple analysis options including Carbon,<br />
Hydrogen, Nitrogen, Sulfur and Oxygen (CHN or CHNS<br />
and O2 analysis.) Plus, the analyzers are backed by<br />
PerkinElmer’s legendary worldwide service and support.
Elemental Analysis<br />
QUICK-FIND INDEX Page #<br />
2400 Series II Analysis Mode 76<br />
Kits<br />
2400 Tubes & Reagent Kits 78<br />
Autoinjector Spares 81<br />
Cables 77<br />
Calibration Standards 80<br />
Fitting Spares 82<br />
Gas Regulators 77<br />
Printer Supplies 77<br />
Reagents 78<br />
Sample Capsules 80<br />
Sample Handling Accessories 80<br />
Tools 82<br />
Tubes 79<br />
Valve Spares 83<br />
PerkinElmer offers a wide selection of superior quality products designed to work with<br />
your PerkinElmer instruments. Our precision designed products deliver the peace of<br />
mind that comes from knowing that you’ll get the results you need.<br />
The Quick Find Index to the left will help you find products fast. For your convenience,<br />
products are alphabetized by category, sub-category, and family. There is also a more<br />
complete Alphabetical INDEX on page 429 and a Part Number INDEX on page 407.<br />
2400 Series II Analysis Mode Kits<br />
2400 Tubes and Reagent Kits<br />
The 2400 Series II offers multiple analysis options: CHN,<br />
CHNS or Oxygen mode. As a user, you may choose one or<br />
more options to meet your laboratories needs. Analysis<br />
Mode Kits supply all the necessary items to changeover<br />
to a different mode of operation. The optional Column<br />
Switching Accessory (CSA) makes switching to the<br />
Oxygen mode very convenient.<br />
Page 76<br />
Convenient Consumable Kits simplify ordering and eliminate<br />
waste. Kits contain the necessary tubes, reagents and<br />
capsules for a defined quantity of runs. Reordering is easy<br />
and predicting annual costs is straightforward.<br />
Page 78<br />
Reagents<br />
Every genuine PerkinElmer reagent is designed specifically<br />
for your PerkinElmer instrument and will assure consistent,<br />
accurate results. Their high quality has been demonstrated<br />
in PerkinElmer instruments all over the world, for a wide<br />
variety of applications.<br />
Page 78<br />
Tubes<br />
PerkinElmer tubes are composed of high purity fused<br />
quartz, with a low thermal expansion rate. This along with<br />
our stringent dimension specifications guarantees the<br />
integrity of your system. All tubes are pressure-tested to<br />
insure your safety.<br />
Page 79
The PerkinElmer 2410 Series II Nitrogen Analyzer measures<br />
the nitrogen and/or protein content in virtually any material<br />
by an advanced combustion process based upon the classical<br />
Dumas method.<br />
Used primarily in the food and agricultural area, the 2410<br />
Series II replaces the time-consuming, multi-stepped Kjeldahl<br />
method of analyzing feeds, grains, cereals, dairy products,<br />
fish, meats, fruits, nuts, fertilizers, plants, soils, and sediments.<br />
Additional application areas are in the polymer and<br />
petroleum industries.<br />
■ Sample sizes up to 500 mgs<br />
■ Analysis time
2400 Series II Analysis Kits<br />
Analysis Kits<br />
CHNS Analysis Kit<br />
Elemental Analysis 2400 Series II Analysis Kits<br />
2400 Instrument<br />
CHN Analysis Kit<br />
CHN Analysis Kit<br />
For automatic determination of carbon, hydrogen, and<br />
nitrogen in organic substances.<br />
Add this optional kit to simultaneously determine CHN<br />
with your PerkinElmer 2400 Series II Analyzer. The sample<br />
is combusted in an oxygen-rich environment at 925 °C. The<br />
resulting reaction products are converted to carbon dioxide,<br />
water, and nitrogen. All of the<br />
reaction products are then<br />
separated and detected.<br />
Kit includes:<br />
Part No.<br />
N2410506<br />
Each (€)<br />
5806<br />
Components Qty. Part No.<br />
2 g Bottle of Acetanilide 1 02401121<br />
Silver Gauze 2 N2410145<br />
Copper Diffusion Plug 1 N2411333<br />
CHN Kit for 2000 Runs 1 N2410683<br />
CHNS Analysis Kit<br />
For automatic determination of carbon, hydrogen, nitrogen,<br />
and sulfur in organic substances.<br />
Add this optional kit to simultaneously determine CHNS<br />
with your PerkinElmer 2400 Series II Analyzer. The sample<br />
is combusted in an oxygen-rich environment at 975 °C. The<br />
resulting reaction products are converted to carbon dioxide,<br />
water, nitrogen, and sulfur dioxide.<br />
All of the reaction products are then<br />
separated and detected.<br />
Kit includes:<br />
Part No.<br />
N2410507<br />
Each (€)<br />
2652<br />
Components<br />
Part No.<br />
10 g Bottle of Sulfamic Acid N2410501<br />
4 g Bottle of Cystine N2410324<br />
2 g Bottle of Acetanilide 02401121<br />
CHNS Kit for 500 Runs<br />
N2410682<br />
Oxygen Analysis Kit<br />
Oxygen Analysis Kit<br />
For automatic determination of oxygen in organic substances.<br />
Add this optional kit to use with your PerkinElmer 2400 for<br />
oxygen analysis. The sample is pyrolyzed in a hydrogen/<br />
helium mixture at 1000 °C. When the resulting reaction<br />
products which contain oxygen pass over platinized carbon,<br />
they are converted to carbon monoxide. The carbon<br />
monoxide and other gases pass through scrubbers,<br />
where interferences are removed, and<br />
the carbon monoxide is then separated Part No. Each (€)<br />
and determined.<br />
N2410513 4056<br />
Kit includes:<br />
Components<br />
Part No.<br />
Quartz Oxygen Pyrolysis Tube<br />
N2411235<br />
Quartz Reduction Tube<br />
N2411300<br />
10 g Bottle of Platinized Carbon 02400119<br />
Platinum Gauze Strip<br />
N2411273<br />
Oxygen Column<br />
N2420212<br />
Quartz Insert<br />
N2411401<br />
454 g Bottle of Copper Plus, Wire Form 02401362<br />
Scrubber Trap Assembly<br />
N2410189<br />
Acid Gas Scrubber Tube<br />
N2411359<br />
100 g Bottle of Colorcarb 02400115<br />
454 g Bottle of Magnesium Perchlorate 02401119<br />
Silver Gauze Strip<br />
N2410145<br />
4 g Bottle of Benzoic Acid 02401120<br />
Not included, but highly recommended for use<br />
with the Oxygen Analysis Kit (N2410513):<br />
Components Part No. Each (€)<br />
Column Switching Accessory N2410265 1441<br />
76
Cables<br />
Weight Transfer Cables<br />
For connection of AD-4 or AD-6<br />
to 2400/2410. (pkg. 1)<br />
Part No. Each (€)<br />
N2410174 261<br />
Laboratory Products<br />
For the 2400/2410 Series II Analyzers<br />
Pyrolysis Gas Regulator<br />
For high purity carrier gas (5% hydrogen in helium) used<br />
with the 2400 Oxygen Analysis mode. Dual stage, stainless<br />
steel diaphragm regulator for high<br />
precision and non-diffusibility. CGA<br />
350 fitting for connection to cylinder.<br />
Part No.<br />
N2410327<br />
Each (€)<br />
861<br />
For connection of TLB-40<br />
or TLB-60 to 2410.<br />
For connection of Mettler Toledo ®<br />
UMX2 ultramicrobalance to a new<br />
or updated 2400 Series II analyzer.<br />
For connection of Sartorius SE2<br />
ultramicrobalance to a new or<br />
updated 2400 Series II analyzer.<br />
Printer Cable<br />
For connection of dot matrix printer<br />
to 2400/2410. (pkg. 1)<br />
Computer Cable<br />
For connection of a PC to 2400.<br />
Gas Lines<br />
Product Part No. Each (€)<br />
Copper Gas Line Assembly (1/8"), Set of 2 Lines N2410170 217<br />
For carrier and combustion gases with the 2400<br />
Plastic Gas Line Assembly (1/4") N2410147 79<br />
For pneumatic gas with the 2400 and 2410<br />
For carrier and combustion gases with the 2410<br />
Gas Pressure Regulators<br />
Helium or Argon Gas Regulator<br />
For 2400 high purity carrier gas, dual stage, stainless steel<br />
diaphragm regulator for high precision<br />
and non-diffusibility. CGA 580 fitting<br />
for connection to cylinder.<br />
Part No.<br />
N2410172<br />
Each (€)<br />
861<br />
Oxygen Gas Regulator<br />
Part No.<br />
Each (€)<br />
04190226 200<br />
Part No.<br />
Part No.<br />
Each (€)<br />
N2410141 179<br />
Part No.<br />
Each (€)<br />
N2410360 73<br />
Part No.<br />
Each (€)<br />
N2410361 74<br />
Each (€)<br />
N2410365 22<br />
For 2400 and 2410 high purity gas, dual stage, stainless steel<br />
diaphragm regulator for high precision<br />
and non-diffusibility. CGA 540 fitting<br />
for connection to cylinder.<br />
Part No.<br />
02400084<br />
Each (€)<br />
606<br />
Pneumatic Gas Regulator<br />
For driving valves in the 2400 and 2410. Single stage, metal<br />
diaphragm regulator. CGA 590 fitting<br />
for connection to cylinder.<br />
Part No. Each (€)<br />
CO 2 Regulator with Warmer<br />
For high purity CO 2 carrier gas, dual stage, metal diaphragm<br />
regulator. Includes CO 2 warmer which requires an electrical<br />
connection. CGA 320 fitting for connection to cylinder.<br />
Voltage Part No. Each (€)<br />
120 V N2410502 1288<br />
230 V N2410503 1288<br />
Printer Kit and Supplies<br />
PE 2400 Series Printer Kit (100/120 V)<br />
For hard copy printout of 2400/2410<br />
data and diagnostics directly<br />
from instrument.<br />
Kit includes:<br />
Components<br />
Part No.<br />
Printer (100/120 V) 09421018<br />
Printer Accessory Kit<br />
N2410248<br />
Includes:<br />
Serial Interface Board 09421021<br />
Printer Paper (3200 sheets)<br />
N5001409<br />
Printer Cable<br />
N2410141<br />
Connects printer to 2400/2410 Analyzer<br />
PE 2400 Series Printer Kit (230 V)<br />
For hard copy printout of 2400/2410<br />
data and diagnostics directly<br />
from instrument.<br />
Kit includes:<br />
Components<br />
N2410173 504<br />
Part No.<br />
Part No.<br />
Printer (230 V) 09421019<br />
Printer Accessory Kit<br />
N2410248<br />
Includes:<br />
Serial Interface Board 09421021<br />
Printer Paper (3200 sheets)<br />
N5001409<br />
Printer Cable<br />
N2410141<br />
Connects printer to 2400/2410 Analyzer<br />
For Ultramicrobalance Supplies, please see Thermal Analysis Section.<br />
Each (€)<br />
N2410021 2079<br />
Part No.<br />
Each (€)<br />
N2410022 2092<br />
Laboratory Products Elemental Analysis<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
77
Packing Supplies<br />
Reagents, Tubes, and Receptacles<br />
2400 Tubes and Reagent Kits<br />
2400 CHN Combustion Tubes<br />
and Reagents for 2000 Runs<br />
Includes: combustion tubes, EA1000,<br />
silver tungstate on magnesium oxide,<br />
silver vanadate and vial receptacles.<br />
Part No. Each (€)<br />
N2410680 927<br />
Elemental Analysis Packing Supplies<br />
2400 CHN Reduction Tubes<br />
and Reagents for 500 Runs<br />
Includes: reduction tubes,<br />
Copper Plus, and copper oxide.<br />
2400 CHNS Combustion/Reduction Tubes<br />
and Reagents for 500 Runs<br />
Includes: combustion/reduction tubes,<br />
EA600, and copper (wire form).<br />
CHN Kit for 2000 Runs<br />
Includes: combustion and reduction<br />
tube and reagent kits and tin capsules.<br />
CHNS Kit for 2000 Runs<br />
Includes: combustion/reduction tube,<br />
reagent kits, and tin capsules.<br />
CHN Reduction Kit Part No. N2410681<br />
CHNS Combustion/Reduction Kit Part No. N2410682<br />
Part No.<br />
Each (€)<br />
N2410681 548<br />
Part No.<br />
Each (€)<br />
N2410682 2345<br />
Part No.<br />
Each (€)<br />
N2410683 5500<br />
Part No.<br />
Each (€)<br />
N2410684 8900<br />
CHN Combustion Kit Part No. N2410680<br />
Packing Supplies<br />
Product Part No. Each (€)<br />
Silver Gauze Strip, (pkg. 1) N2410145 87<br />
Platinum Gauze Strip, (pkg. 1) N2411273 740<br />
Quartz Wool, (50 g) 02401118 172<br />
Copper Diffusion Plug, (pkg. 1) N2411333 48<br />
Reagents<br />
Product Part No. Each (€)<br />
EA-1000, (50 g) N2410092 217<br />
EA-1000, (3 x 50 g) N2410166 536<br />
Silver Tungstate/Magnesium Oxide, (100 g) 02401344 536<br />
Silver Tungstate/Magnesium Oxide, (3 x 100 g) N2410165 1390<br />
Silver Vanadate, (40 g) 02401117 116<br />
Silver Vanadate, (3 x 40 g) N2410164 281<br />
EA-6000, (50 g) N2410278 269<br />
EA-6000, (5 x 50 g) N2410331 874<br />
Platinized Carbon, (10 g) 02400119 670<br />
Copper Plus, (454 g) 02400117 217<br />
Copper Plus, (10 x 454 g) N2410157 1492<br />
Copper Plus – Wire Form, (454 g) 02401362 236<br />
Copper Plus – Wire Form, (5 x 454 g) N2410332 874<br />
Copper for Nitrogen, (454 g) N2411527 115<br />
Copper for Nitrogen, (10 x 454 g) N2410518 944<br />
Copper Oxide – Wire Form, (454 g) 02401092 134<br />
Aquasorb (25 g) N2410277 77<br />
Colorcarb, (100 g) 02400115 107<br />
Colorcarb, (3 x 100 g) N2410188 395<br />
Magnesium Perchlorate, (454 g) 02401119 217<br />
Magnesium Perchlorate, (3 x 454 g) N2410191 395<br />
Thermolite, (100 g) 02400815 47<br />
78
Packing Supplies<br />
Reagents, Tubes, and Receptacles<br />
Receptacles<br />
Description Part No. Each (€)<br />
Quartz Tube Insert, (pkg. 1) N2411401 56<br />
Vial Receptacle<br />
For use with the 2400 in the CHN<br />
mode and with the 2410. pkg. 1<br />
Vial Receptacle<br />
For use with the 2400 in the CHNS and Oxygen modes.<br />
Recommended in CHN mode when a large amount of<br />
inert material will be left after the organic material has<br />
combusted. pkg. 10<br />
Part No. Each<br />
Tubes<br />
Part No.<br />
Each (€)<br />
N2411335 56<br />
N2410177 370<br />
PerkinElmer tubes are composed of pure fused quartz which<br />
is 99% SiO 2 . Fused quartz has been chosen because of its<br />
very high purity and low thermal expansion rate. Because<br />
we care about your safety, all combustion tubes are pressuretested<br />
to eliminate any tubes which might contain weak<br />
spots. In addition, stringent specifications are used to ensure<br />
that the combustion tubes fit in an airtight connection when<br />
placed in the analyzer.<br />
Type Material Analyzer Mode Qty. Part No. Each (€)<br />
Combustion Quartz 2400 CHN 1 N2411264 185<br />
Combustion Quartz 2400 CHN 3 N2410212 453<br />
Combustion Quartz 2400 CHN 10 N2410153 1301<br />
Combustion/ Quartz 2400 CHNS 1 N2411514 185<br />
Reduction<br />
Combustion/ Quartz 2400 CHNS 5 N2410330 733<br />
Reduction<br />
Combustion Stainless 2410 Nitrogen 1 N2421070 79<br />
or Reduction Steel<br />
Combustion Quartz 2410 Nitrogen 1 N2411487 93<br />
Pyrolysis Quartz 2400 Oxygen 1 N2411235 172<br />
Reduction Quartz 2400 Oxygen 1 N2411300 77<br />
& Sulfur<br />
Reduction Quartz 2400 CHN 1 N2411291 159<br />
Reduction Quartz 2400 CHN 10 N2410154 1269<br />
Scrubber Pyrex ® 2400/ Oxygen 1 N2411359 140<br />
2410 & Nitrogen<br />
(€)<br />
Combustion and Pyrolysis Tubes<br />
Reduction Tubes<br />
Packing Supplies Elemental Analysis<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
79
Sample Handling<br />
Calibration Standards, Capsules, and Supplies<br />
Calibration Standards<br />
Sample Capsules<br />
Elemental Analysis Sample Handling<br />
80<br />
Before using your elemental analyzer to analyze unknown<br />
materials, you must calibrate it. Combustion standards burn<br />
readily, and their known composition of carbon, hydrogen,<br />
nitrogen, oxygen, and sulfur can be used to calibrate your<br />
elemental analyzer.<br />
The PerkinElmer Combustion Standards are stable materials<br />
which are not subject to ambient influences and are<br />
recommended for the PerkinElmer 2400/2410 and Model<br />
240 instruments.<br />
Acetanilide<br />
Is routinely used during the carbon, hydrogen, and nitrogen<br />
operation mode. The sample weight percentages of this<br />
compound are:<br />
Carbon = 71.09%<br />
Hydrogen = 6.71%<br />
Nitrogen = 10.36%<br />
Benzoic Acid<br />
Is used as the combustion standard with the Oxygen<br />
Analysis Kit. The sample weight percentages of this<br />
compound are:<br />
Carbon = 68.85%<br />
Hydrogen = 4.95%<br />
Nitrogen = 0.0%<br />
Oxygen = 26.20%<br />
Cyclohexanone 2, 4 Dinitrophenylhydrazone<br />
Is another recommended standard for CHN analysis.<br />
This compound contains:<br />
Carbon = 51.19%<br />
Hydrogen = 5.07%<br />
Nitrogen = 20.14%<br />
Cystine<br />
Is a standard which is used for sulfur determination.<br />
Its composition is:<br />
Carbon = 29.99%<br />
Hydrogen = 5.03%<br />
Nitrogen = 11.66%<br />
Sulfur = 26.69%<br />
EDTA<br />
Is a standard used routinely for nitrogen analysis<br />
with the PerkinElmer 2410. Its composition is:<br />
Nitrogen = 9.59%<br />
Sulfamic Acid<br />
Is used to condition a new<br />
CHNS analysis tube.<br />
Qty. Part No. Each (€)<br />
2 g 02401121 210<br />
Qty. Part No. Each (€)<br />
4 g 02401120 82<br />
Qty. Part No. Each (€)<br />
1 g 02401347 110<br />
Qty. Part No. Each (€)<br />
4 g N2410324 196<br />
Qty. Part No. Each (€)<br />
100 g N2410325 77<br />
Qty. Part No. Each (€)<br />
10 g N2410501 62<br />
Product Qty. (pkg.) Part No. Each (€)<br />
Tin Capsules<br />
For analysis of nonvolatile solid samples.<br />
Standard Tin Capsule Kit 96 N2411255 102<br />
96 (10 pkgs.) N2410155 861<br />
Large Tin Capsule Kit 250 N2411362 116<br />
Flat Tin Disks<br />
For analyzing 13 or 25 mm filters.<br />
Flat Tin Disks 100 N2411363 98<br />
100 (10 pkgs.) N2410244 797<br />
Aluminum Capsules<br />
For analyzing volatile liquid samples. Requires, but does<br />
not include: Liquid Sample Sealer (B0198093) and Tin<br />
Capsules (N2411255, N2410155, or N2411362).<br />
Aluminum Capsules, 4 μL 1000 02400642 236<br />
Aluminum Capsules, 30 μL 1000 00090709 268<br />
Tin Pans and Covers<br />
For volatile liquid or solid samples, including viscous<br />
materials. Requires, but does not include: Volatile Sample<br />
Sealer (02190061).<br />
Volatile Tin Sample Pans and Covers 400 N2410320 606<br />
Silver Capsules<br />
For analyzing organic substances with Oxygen Analysis.<br />
Silver Capsules 96 N2411364 198<br />
Sample Handling Accessories<br />
Sample Handling Kit<br />
Kit includes:<br />
Description<br />
Part No.<br />
One Hayman Microspatula 02401286<br />
Five Brushes 02401296<br />
One Hook Tweezers 09908138<br />
One Flat Forceps 09908400<br />
One Pedestal for Sample Capsule<br />
N2411267<br />
Sealers<br />
Liquid Sample Sealer<br />
For use with volatile, nonviscous, noncorrosive samples.<br />
Tin/Aluminum Capsules must be ordered separately. Kit<br />
includes: one Capsule Sealing Unit,<br />
one Magazine for 4 and 30 μL Capsules,<br />
and one Instruction Manual.<br />
Part No.<br />
B0198093<br />
Each (€)<br />
1090<br />
Volatile Sample Sealer<br />
For use with volatile, viscous,<br />
noncorrosive samples.<br />
Part No.<br />
Each (€)<br />
N2410146 325<br />
Part No.<br />
Each (€)<br />
02190061 1528
Spare Parts and Tools<br />
Autoinjector and Fitting Spares<br />
Autoinjector Spares<br />
O-Ring, Auto-Injector RAM<br />
Description Part No. Each (€)<br />
For use with 2400 (pkg. 1) 09902048 9<br />
For use with 2410 (pkg. 1) 09902035 3<br />
Spring, Auto-Injector RAM<br />
For use with the 2400 and 2410.<br />
(pkg. 1)<br />
O-Ring, Sample Drop Valve<br />
For use with the 2400 and 2410.<br />
Fittings for Combustion<br />
and Reduction Tubes<br />
Part No.<br />
Each (€)<br />
09920404 3<br />
Part No.<br />
Each (€)<br />
09902123 17<br />
A variety of hardware fittings are required to connect the<br />
glassware to your PerkinElmer Elemental Analyzer. The<br />
nuts, washers, O-Rings, and other fittings listed here are<br />
identical to the parts which were shipped with your<br />
instrument. Use them as replacement parts to ensure<br />
perfect connections.<br />
Components Part No. Each (€)<br />
1 Filter Disk, 11 mm, (pkg. 12) 02400137 48<br />
For use with Crossover Fitting<br />
Bracket Assembly (N2410315)<br />
Filter Disk, 25 mm, (pkg. 12) N2410237 77<br />
For use with Crossover Fitting<br />
Bracket Assembly (N2420214)<br />
2 O-Ring, 25 mm Silicone, (pkg. 1) 09902188 2<br />
3 For use with the<br />
2400 Combustion Tube3<br />
2 O-Ring, 25 mm Viton ® , (pkg. 1) 09902048 9<br />
3 For use with the 2410 Combustion<br />
and Reduction Tube<br />
3<br />
3 Glass Tube Washer, 25 mm, (pkg. 1) N2411118 9<br />
4 Glass Tube Nut, 25 mm, (pkg. 1) N2411117 56<br />
5 25 mm Combustion Tube Ceramic N2411341 38<br />
Ring, (pkg. 1)<br />
6 O-Ring, 11 mm Viton, (pkg. 12) 02401583 14<br />
7 Glass Tube Washer, 11 mm, (pkg. 1) 02401042 5<br />
8 Glass Tube Nut, 11 mm, (pkg. 1) 02401028 28<br />
9 11 mm Reduction Tube Ceramic Ring, N2411342 38<br />
10 (pkg. 1)<br />
10<br />
Crossover Fitting Bracket Assembly<br />
For use with 2400 (pkg. 1) N2410315 798<br />
For use with 2410 (pkg. 1) N2420214 363<br />
1<br />
2<br />
6<br />
7<br />
3<br />
8<br />
4<br />
9<br />
5<br />
Reduction Chamber<br />
Combustion Chamber<br />
8<br />
7<br />
8<br />
6<br />
7<br />
1<br />
6<br />
1<br />
10<br />
PerkinElmer 2400 CHNS/O Combustion and Reduction Tube Connections<br />
Spare Parts and Tools Elemental Analysis<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
81
Spare Parts and Tools<br />
Fittings and Tools<br />
Fittings for Scrubber<br />
Spare Parts for 2400/2410<br />
Elemental Analysis Spare Parts and Tools<br />
1<br />
6<br />
7<br />
8<br />
11<br />
Components Part No. Each (€) Description Part No. Each (€)<br />
Filter Disk, 11 mm, (pkg. 12) 02400137 48<br />
For use with bottom end of<br />
Scrubber Tube (N2411359)<br />
O-Ring, 11 mm Viton, (pkg. 12) 02401583 14<br />
Glass Tube Washer, 11 mm, (pkg. 1) 02401042 5<br />
Glass Tube Nut, 11 mm, (pkg. 1) 02401028 28<br />
Scrubber Tube N2411359 140<br />
For use with 2400 in oxygen analysis<br />
mode as an acid-gas scrubber<br />
For use with 2410 in nitrogen as a<br />
water scrubber<br />
11<br />
8<br />
8<br />
6<br />
7<br />
6<br />
7<br />
1<br />
Upper<br />
Movable<br />
Bracket<br />
PerkinElmer 2400 CHNS/O<br />
Acid-Gas Scrubber Connections<br />
Solenoid In-line Filter Assembly 09903665 56<br />
Solenoid In-line Filter (pkg. 1) 09903673 36<br />
Replacement 10 Micron Filter for (09903665)<br />
Pneumatic Valve N2411019 236<br />
Tools<br />
Product Part No. Each (€)<br />
25 mm Tube Wrench for the 2400/2410 N2411144 21<br />
11 mm Tube Wrench for the 2400/2410 09907204 48<br />
Spanner Wrench for the Normally Open 02401294 10<br />
and Normally Closed Valves<br />
Retrieving Wire for the 2400/2410 N2411274 48<br />
Receptacle Removal<br />
82
Spare Parts and Tools<br />
Valve Spares<br />
Valve Spares<br />
Your elemental analyzer contains several valves that control<br />
the flow of gases which combust your sample and carry it<br />
through the instrument. The valves labeled A, B, D, E, F,<br />
and H are Normally Closed Valves. When rebuilding a<br />
Normally Closed Valve, you should replace the Plunger<br />
(N2411257), Plunger Spring (02401291), and the O-Ring<br />
(02401293). The D and E valves in the Effluent Manifold,<br />
direct the sample gas into the mixing volume portion of the<br />
system. These two valves contain an In-Line Filter<br />
Assembly (09903665), to filter residue or dirt particles<br />
which could affect the valves’ efficiency. The 10-micron<br />
filter (09903673) inside the filter assembly will require<br />
periodic replacement. On the Normally Open C Valve, the<br />
Plunger (02402087), Plunger Spring (N2411374), O-Ring<br />
(02401293), and Adapter Seal (02402089) must be replaced.<br />
To keep your instrument operating efficiently, you should<br />
clean and rebuild valves every year. Certain other parts, too,<br />
will require periodic replacement. The parts offered here can<br />
all be replaced without the assistance of a service engineer.<br />
They are all identical to the parts which were originally<br />
supplied with your analyzer. Instructions for replacing<br />
these parts are included in your operator’s manual.<br />
Normally Closed Valve Assembly<br />
2<br />
1<br />
3<br />
Components Part No. Each (€)<br />
Valve Plunger Spring 02401291 9<br />
Valve Plunger N2411257 38<br />
Valve O-Ring 02401293 9<br />
Normally Open Valve Assembly<br />
6<br />
4<br />
5<br />
3<br />
Part No.<br />
Each (€)<br />
N2411087 172<br />
Part No.<br />
Each (€)<br />
N2411088 230<br />
Components Part No. Each (€)<br />
Valve O-Ring Adapter 02402089 9<br />
Valve Plunger 02402087 65<br />
Valve Plunger Spring N2411374 14<br />
Valve O-Ring 02401293 9<br />
1<br />
3<br />
2<br />
Normally Closed Valve<br />
Part No. N2411087<br />
4<br />
3<br />
5<br />
Normally Open Valve<br />
Part No. N2411088<br />
6<br />
Spare Parts and Tools Elemental Analysis<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
83
Whichever piece of the planet<br />
you’re monitoring, we can help.<br />
PerkinElmer’s global environmental<br />
expertise goes beyond instruments,<br />
software and laboratory information<br />
management systems. Whether your<br />
analyses require organic or inorganic<br />
methods, PerkinElmer has the products—<br />
and the people—to help your lab achieve<br />
greater productivity, efficiency and compliance<br />
with complex regulations.<br />
We incorporate the planet’s best practices<br />
into our products and impart them to<br />
you with our knowledgeable support.<br />
And with over 1,000 factory-trained<br />
professionals worldwide, we provide<br />
rapid service response to maximize<br />
uptime. So no matter what you analyze,<br />
if you want to do it better, smarter and<br />
faster, contact PerkinElmer.<br />
© 2005 PerkinElmer, Inc. 400056_01<br />
800-762-4000 (U.S. and Canada)<br />
(+1) 203-925-4602<br />
For a complete listing of our global offices, visit: www.perkinelmer.com/lasoffices<br />
www.perkinelmer.com
PerkinElmer continues to drive innovation<br />
and performance in Gas Chromatography<br />
(GC) instrumentation and software, with<br />
a strong focus on making your lab more<br />
productive. Backed by our worldwide,<br />
world-class service and support team,<br />
PerkinElmer GC products are a great fit<br />
for your modern, fast-paced lab.<br />
PerkinElmer is the only GC supplier<br />
that manufactures and sells a complete<br />
single-vendor solution – from sample<br />
handling to data handling. This means<br />
you will not struggle to find answers to<br />
applications and service questions – one<br />
company provides the complete solution.<br />
Gas Chromatography
Gas Chromatography<br />
QUICK-FIND INDEX Page #<br />
Autosampler Accessories<br />
Vials, Caps and Septa 89<br />
Autosampler Syringes 88<br />
Capillary Columns Accessories 92<br />
Capillary Columns 91<br />
Capillary Injectors 150<br />
Detectors 131<br />
Ferrules 94<br />
Gas Purification Systems 164<br />
Gas Sampling Supplies 163<br />
Headspace Accessories<br />
and Supplies 143<br />
Filters and Traps 163<br />
Headspace Vials, Caps,<br />
and Septa 148<br />
Hydrogen Generators 165<br />
Injector Liners 157<br />
PerkinElmer offers a wide selection of superior quality products designed to work with<br />
your PerkinElmer instruments. Our precision-designed products deliver the peace of<br />
mind that comes from knowing that you’ll get the results you need.<br />
The Quick Find Index to the left will help you find products fast. For your convenience,<br />
products are alphabetized by category, sub-category, and family. There is also a more<br />
complete Alphabetical INDEX on page 429 and a Part Number INDEX on page 407.<br />
Headspace Vials, Caps, and Septa<br />
PerkinElmer’s patented vial and cap design incorporates<br />
pressure relief features which guarantee safe operation with<br />
the high pressure typically developed during thermostatting.<br />
These vials have a greater wall thickness and round base<br />
which enables them to withstand pressure up to 60 psig.<br />
PerkinElmer septa are designed for the patented pressure<br />
release cap to ensure safe operation at higher temperatures. Available pre-assembled<br />
into caps with starsprings.<br />
Page 148<br />
Capillary Columns<br />
We use only the finest quality of high-strength fused silica in<br />
the manufacture of our columns. Each column is individually<br />
inspected and tested to guarantee you the highest<br />
performance and to maximize reproducibility.<br />
Page 91<br />
Injector Septa 159<br />
Ozone Precursor 180<br />
PerkinElmer TotalChrom<br />
Software 173<br />
Swagelok Fittings 95<br />
Syringes 161<br />
Thermal Desorber Stainless<br />
Steel and Glass Tubes 181<br />
Thermal Desorber Traps<br />
and Fittings 182<br />
Valves 168<br />
Vial Crimping Tools 90<br />
Syringes<br />
PerkinElmer Injector Syringes have been tested and<br />
optimized for use with a 7 cm needle. This is critical for<br />
depositing sample in the optimal zone. Syringes are<br />
individually inspected for accuracy and performance.<br />
Syringes for 0.5 μL to 50 μL capacity in two different point<br />
styles are available. PerkinElmer ultra micro volume syringes are recommended for<br />
sample injection of less than 5 μL.<br />
Page 161<br />
Hydrogen Generators<br />
The patented DBS PG-H 2 series of Hydrogen Pure Gas<br />
Generators is ideal for operation with gas analyzers as a<br />
source of pure hydrogen in plasma chambers and other<br />
isolated environments. Electrolytic membrane technology<br />
is preferred over alternative hydrogen generating techniques<br />
because it is clean, requires less maintenance, and there is<br />
no need to store chemicals to maintain operation.<br />
Page 165
Clarus GC<br />
Sleek design and easy touch screen<br />
revolutionize GC interaction<br />
Gas chromatography started in 1952, with the seminal work of A.J.P.<br />
Martin and A.T. James and, within a few years, it became one of the<br />
most popular analytical techniques. PerkinElmer played a crucial role in<br />
the development of the technique:<br />
Clarus 500 GC<br />
■ Dual-channel, real-time signal display<br />
on the touch screen<br />
■ Flexible configurations with<br />
integrated mass spectrometry,<br />
headspace or thermal desorption<br />
and pyrolysis samplers<br />
■ Temperature-programmable inlets<br />
maximize reproducibility<br />
■ Pneumatic Pressure Controllers (PPC)<br />
provide accurate and highly<br />
reproducible gas controls<br />
■ GC analysis at your fingertips<br />
■ Easy setup/method development<br />
■ Multiple-language support<br />
■ Enhanced Solvent Purge mode<br />
■ Isolation mode<br />
■ High-pressure pulse injection<br />
■ Large-volume injection<br />
■ Petrochemical analysis from Hydrogen<br />
to Asphalt<br />
■ Ozone Precursors analysis<br />
■ Air Toxics analysis<br />
■ Food and Beverage quality control<br />
The sleek Clarus ® Gas Chromatograph<br />
from PerkinElmer offers a whole new<br />
approach to the way you interact with<br />
your GC instrument. An intuitive touchscreen<br />
interface features real-time signal<br />
display and eight-language support.<br />
Available in hundreds of configurations<br />
ranging from dedicated analyzers for<br />
petrochemical and air analysis to powerful<br />
mass spectrometer units, the Clarus GC is<br />
extremely flexible. For applications<br />
requiring mass spectrometer detection,<br />
the Clarus GC can be coupled to the<br />
industry’s easiest-to-use and widestmass-range<br />
quadrupole mass spectrometer.<br />
The Clarus GC features the PerkinElmerexclusive<br />
PreVent operating mode. This<br />
powerful mode uses the combined<br />
features of the temperatureprogrammable<br />
PSS injector and the PPC,<br />
to increase analytical throughput, manage<br />
difficult samples, protect the column and<br />
chromatograph and lower detection limits<br />
PerkinElmer’s award-winning datahandling<br />
software makes managing<br />
data easier than ever.<br />
Combine the Clarus GC with the Clarus<br />
Mass Spectrometer (MS), market-leading<br />
PerkinElmer TurboMatrix samplehandling<br />
accessories, flexible user-friendly<br />
TotalChrom ® software and world-class<br />
service and support for an integrated,<br />
complete analytical solution.<br />
The totally integrated Clarus autosampler<br />
provides flexibility and automation<br />
capability for the gas chromatograph.<br />
The autosampler accommodates three<br />
autosampler syringe sizes (0.5, 5.0, and<br />
50 μL) and three injection speeds (slow,<br />
normal, and fast), for complete application<br />
flexibility. Unobstructed access to either<br />
injection port with one autosampler<br />
permits any combination of analyses<br />
for the most efficient utilization of<br />
the gas chromatograph.<br />
The Clarus MS features a wealth of<br />
innovative technology to provide the most<br />
complete characterization of samples.<br />
PerkinElmer Selected Ion and Full Ion<br />
(SIFI) scanning technology and high<br />
scan speeds increase system accuracy.<br />
The mass spectrometer boasts a fast<br />
scanning speed with the widest mass<br />
range available for GC/MS, providing<br />
capability to analyze a greater scope<br />
of applications.<br />
The combination of a Clarus GC with a<br />
data-handling system provides a total<br />
laboratory solution from data collection<br />
and analysis to reporting and storage.<br />
87
Autosampler Accessories<br />
Syringes and Accessories<br />
Autosampler Replacement Parts<br />
Description Part No. Each (€)<br />
Gas Chromatography Autosampler Accessories<br />
1 Replacement Vial Locator (may require N6101182 14<br />
service installation, not included)<br />
2 Spring (pkg. 1)* N6101183 4<br />
3 Shoulder Screw (pkg. 1)* 09907998 3<br />
* Requires two for complete installation. See illustration.<br />
Miscellaneous Accessories<br />
Autosampler Starter Kit<br />
Includes: 5 μL x 0.63 mm o.d. syringe, 2 mL clear sample<br />
vials (100), 2 mL amber sample vials (100), blue crimp<br />
caps with septa (100), green crimp caps with septa (100),<br />
red crimp caps with septa (100), septa for waste/wash<br />
vials (100), crimper – 11 mm,<br />
decapper – 11 mm, 2 mL vial rack. Part No. Each<br />
Autosampler Thermostatting Accessory<br />
Allows thermostatting of Autosampler tray from 10 to 50 °C.<br />
Accessory includes: tubing, tie wraps,<br />
clamp, and instructions.<br />
(Circulating bath not included.)<br />
Part No.<br />
N6120036<br />
Each (€)<br />
286<br />
AutoSystem XL Autosampler<br />
Add-On Accessory (White Color)<br />
Note: Cannot be installed on an AutoSystem.<br />
Service installation is required.<br />
Spare Autosampler Tray<br />
1<br />
3<br />
2<br />
N6120105 791<br />
Part No.<br />
Each (€)<br />
N6120181 10000<br />
Part No.<br />
(€)<br />
Each (€)<br />
N6120031 287<br />
5 μL Syringe for Autosampler Part No. N6101390<br />
Syringes<br />
Replacement Needles for 0.5 μL Syringes<br />
0.5 μL Syringes<br />
Needle o.d. Part No. Each (€)<br />
0.47 N6101470 74<br />
0.63 N6101469 74<br />
Recommended Use Needle o.d. Part No. Each (€)<br />
Low injection volume. 0.53 capillary 0.47 N6101253 210<br />
on-column injection. Plunger type: Metal<br />
Plunger in needle type<br />
Low injection volume analyses 0.63 N6101252 210<br />
Plunger type: Metal<br />
Plunger in needle type<br />
5 μL Syringes<br />
Recommended Use Needle o.d. Part No. Each (€)<br />
0.53 capillary on-column injection 0.47 N6101380 113<br />
Plunger type: metal. Plunger in barrel<br />
Routine analyses. Plunger type: metal 0.63 N6101251 110<br />
Plunger in barrel<br />
Routine analyses. Shipped standard 0.63 N6101390** 110<br />
with instrument. Plunger type: metal<br />
Plunger in barrel with Teflon ® -tipped seal<br />
** Shipped standard with instrument<br />
50 μL Syringe<br />
Recommended Use Needle o.d. Part No. Each (€)<br />
Metal plunger in barrel type 0.47 N9302799 223<br />
Metal plunger in barrel type 0.63 N6101760 200<br />
88
Autosampler Accessories<br />
Vials, Caps, and Septa<br />
Crimp Caps and Septa<br />
Screw Top Sample Vials and Caps<br />
Crimp Caps<br />
Aluminum crimp caps and<br />
septa for 11 mm sample vial,<br />
Teflon ® /rubber.<br />
Description Part No. Each (€)<br />
Blue Crimp Caps and Septa (pkg. 100) N9302686 41<br />
Green Crimp Caps and Septa (pkg. 100) N9302684 35<br />
Red Crimp Caps and Septa (pkg. 100) N9302685 37<br />
Silver Crimp Caps and Septa (pkg. 100) N9306015 25<br />
Viton ® Septa Crimp Caps<br />
These Viton septa caps are recommended for applications<br />
that require work with chloroform.<br />
Part No. Each (€)<br />
Crimp Top Sample Vials<br />
Amber (11 mm) vial for photosensitive samples,<br />
2 mL volume. Caps and septa not included.<br />
Low-Volume Sample Inserts<br />
N9302784 1035<br />
Part No.<br />
200 μL low volume glass inserts for crimp cap sample vials.<br />
Supports required but not included.<br />
Description Part No. Each (€)<br />
Insert (pkg. 1000) N9302681 471<br />
Support (pkg. 500) N9302682 77<br />
Clear (11 mm) sample<br />
vial, 2 mL volume.<br />
Caps and septa not<br />
included. (pkg. 100)<br />
Each (€)<br />
N9302680 31<br />
Part No.<br />
Each (€)<br />
N9301385 18<br />
These vials are custom designed for the AutoSystem Series<br />
and Clarus GC. (Not to be used with low-volume insert.)<br />
Description Part No. Each (€)<br />
Cap, for Screw Top Vial (pkg. 100) N9303441 10<br />
Septa for Screw Top Cap (pkg. 100) N9303442 22<br />
PTFE-Coated Butyl Rubber<br />
Vial, Clear Glass Screw Top (pkg. 100) N9302945 41<br />
Vial Holder Racks<br />
Keep your samples organized and tip proof! These rugged,<br />
plastic vial racks are great for holding vials while you load<br />
and cap your samples. They stack away neatly when done.<br />
Description Part No. Each (€)<br />
36 vial capacity, 20 mm N9301304 33<br />
50 vial capacity, 11 mm N9301303 33<br />
Waste Vials<br />
Description Part No. Each (€)<br />
Cap for Waste and Wash Vials (15 mm), (pkg. 1) 09923032 1<br />
Clear Waste and Wash Vial 4 mL (15 mm), (pkg. 1) 09923031 1<br />
Septa for Waste Wash Vials N9302780 37<br />
For use with viscous or toxic samples<br />
Diffusers for Waste and Wash Vials<br />
Diffusers are sold exclusively by PerkinElmer. The conical<br />
shape allows the needle to penetrate into solvent or waste.<br />
Reduces spillage and large losses<br />
through evaporation.<br />
Part No. Each (€)<br />
N6101276 1<br />
Autosampler Accessories Gas Chromatography<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
89
Autosampler Accessories<br />
Vial Crimping Tools<br />
Crimping Tools<br />
Gas Chromatography Autosampler Accessories<br />
Benchtop Crimper Part No. N6621006<br />
Electronic Crimper Part No. N9302567 (120 V)<br />
Benchtop Crimper<br />
Sturdy, rugged stand will accept three size jaws.<br />
Jaws required but not included.<br />
Part No.<br />
Jaws for Benchtop Crimpers<br />
Description Part No. Each (€)<br />
AutoSystem GC Vials, 11 mm N6621008 391<br />
Headspace Vials, 20 mm N6621009 344<br />
Electronic Crimpers<br />
Electronic crimpers and decappers are easy to use and<br />
fully rechargeable. Ergonomically designed to alleviate<br />
the potential for Carpal Tunnel Syndrome and provide a<br />
consistent crimp pressure numerous times. The unit comes<br />
with a standard Black and Decker VersaPak ® Gold battery<br />
and charger, and will crimp several hundred vials on<br />
one charge. Crimping pressure is fully adjustable for<br />
precision control.<br />
Description Part No. Each (€)<br />
11 mm Electronic Crimper 120V N9302567<br />
11 mm Electronic Crimper 200V N9302568 700<br />
11 mm Electronic Crimper 230V N9302569 700<br />
11 mm Electronic Crimper 240V N9302570 700<br />
11 mm Electronic Decapper 120V N9302575<br />
11 mm Electronic Decapper 200V N9302576 700<br />
11 mm Electronic Decapper 230V N9302577 700<br />
11 mm Electronic Decapper 240V N9302578 700<br />
Electronic Crimper Replacement Battery N9302585 44<br />
Hand Crimpers<br />
Description Part No. Each (€)<br />
1.5 mL (AutoSystem GC sample vials), 11 mm 00090699 263<br />
6.0 mL and 20.0 mL (headspace vials), 20 mm N9302785 256<br />
Economy Cap Removal Tool<br />
Each (€)<br />
N6621006 1685<br />
Description Part No. Each (€)<br />
11 mm Autosampler Crimp Caps N9301390 64<br />
20 mm Headspace Crimp Caps N9301270 64<br />
90
Capillary Columns<br />
Capillary Columns<br />
Capillary Columns<br />
Top 10 Reasons to Buy<br />
PerkinElmer Elite Series<br />
Capillary Columns<br />
1 Finest quality of high-strength fused silica<br />
2 Each column individually inspected and tested<br />
3 Reproducible results<br />
4 Crosslinked and bonded stationary phase<br />
5 Robust column cage<br />
6 Superior resolution<br />
7 Wide selection of stationary phases available<br />
8 Reduced baseline bleed<br />
9 Lower baseline noise<br />
10 Column lengths from 5 to 105 m<br />
Why choose fused silica?<br />
Many factors influence the quality<br />
of a column. Fused silica is considered<br />
to be the purest form of glass, with fewer<br />
metal oxides (Lewis acid sites) and<br />
hydrogen bonding (surface silanol)<br />
groups. The stationary phase is cross<br />
linked (polymerized) and also bonded<br />
to the surface of the column to provide<br />
a high degree of stability, resulting in<br />
lower bleeding of the stationary phase<br />
at elevated temperatures. The superior<br />
inertness of the column means that<br />
acidic and basic compounds can be<br />
analyzed on the same column.<br />
Selecting the right stationary phase<br />
The inherent efficiency (large number<br />
of theoretical plates) of capillary columns<br />
allows you to choose from relatively few<br />
types of phases, compared to the many<br />
varieties of packed columns previously<br />
required. Perhaps more importantly,<br />
because capillary columns are more<br />
efficient, you will see superior resolution<br />
resulting in narrower, taller peaks that<br />
allow easier integration from your data<br />
system. Identification of small peaks are<br />
facilitated by a reduced baseline bleed<br />
and lower baseline noise. Non-polar<br />
Elite-1 columns from PerkinElmer will<br />
preferentially retain non-polar<br />
compounds, whereas the PerkinElmer<br />
Elite-200 column phase provides<br />
high selectivity for analytes containing<br />
lone pair electrons, such as nitro and<br />
carbonyl groups. Elite-WAX polyethylene<br />
glycol columns are highly selective<br />
toward polar compounds such as alcohols.<br />
What length do I need?<br />
Typically, capillary columns are available<br />
in lengths from 5 to 105 meters. The<br />
longer the column the more resolving<br />
power, but this also increases the analysis<br />
time. Doubling a column length only<br />
increases resolution by approximately<br />
40% but, under isothermal conditions,<br />
will double the analysis time. If using<br />
a temperature programmed analysis,<br />
retention times are more dependent on<br />
the temperature than on the column<br />
length. PerkinElmer provides columns<br />
in the most popular lengths of 5, 10, 12,<br />
15, 25, 30, 50, 60, 75, 100, and 105 m<br />
depending upon the column i.d.<br />
91
Capillary Column Accessories<br />
Adapter Kits<br />
Gas Chromatography Capillary Column Accessories<br />
Adapter Kit Accessories<br />
Detector Receiver<br />
1/8 to 1/16 in. detector receiver for<br />
use when using capillary columns<br />
with FID, ECD, NPD, and FPD.<br />
Flow Accessory 0-20 mL<br />
For use when converting an<br />
AutoSystem flow controller<br />
to low-flow operation.<br />
Flow Accessory 0-100 mL<br />
Shipped as standard with instrument.<br />
Injector/Detector Adapter for<br />
Fused-Silica Capillary Columns<br />
This 1/8 to 1/16 in. stainless steel<br />
reducer can be easily installed. For<br />
use when installing capillary columns<br />
on the 1/8 in. split/splitless injector<br />
and all 1/8 in. detector fittings. The<br />
reducer allows the use of 1/16 in. graphite/vespel ferrules<br />
rather than the larger 1/8 in. ferrule.<br />
(Not compatible with AutoSystem<br />
Part No. Each (€)<br />
or Clarus Series.)<br />
N9300063 130<br />
Wafer Scribe<br />
The ceramic wafer scribe is inexpensive and ideal for<br />
cutting polyimide fused-silica capillary columns. The scribe<br />
is easy to hold and simple to use.<br />
All four sides can be used. (pkg. 10) Part No. Each (€)<br />
Wide-Bore Adapter Kit<br />
AutoSystem GC Adapter Kit<br />
Part No.<br />
Each (€)<br />
N6120020 69<br />
Part No.<br />
Each (€)<br />
N6101377 261<br />
Part No.<br />
Each (€)<br />
N6102190 185<br />
N9301376 59<br />
The 0.53 mm Capillary Column<br />
Adapter Kit from PerkinElmer<br />
contains all the parts necessary to<br />
adapt packed column injectors<br />
quickly and easily for use with<br />
wide-bore capillary columns. For accurate control of the<br />
low flows used in wide-bore capillary columns (down to<br />
1 mL/min.). Kit includes 0-20 mL/min. flow controller<br />
element, wide-bore adapter with 1/16 in. fitting, wide-bore<br />
glass liner and column support hanger. May be used in both<br />
on-column or off-column modes.<br />
(For AutoSystem GC Series only.) Part No. Each (€)<br />
N6120001 523<br />
Wide-Bore Kit<br />
Replacement Parts<br />
Column Nut 1/16 in.<br />
Replacement 1/16 in. column nut.<br />
Connects capillary column to adapter.<br />
Graphite/Vespel 1/16 in. Ferrule<br />
1/16 in. x 0.8 mm i.d. For connecting<br />
capillary columns to adapter liner.<br />
Graphite/Vespel 1/4 in. Ferrule<br />
For installing adapter liner into injector.<br />
Graphite Ferrule<br />
Reverse ferrules used to connect 0.53 mm capillary columns<br />
to wide-bore adapter kit. 1/16 in. fitting. Reverse ferrule<br />
1/16 in. x 0.8 mm i.d. (pkg. 10)<br />
Part No. Each (€)<br />
Graphite/Vespel Ferrule<br />
Reverse ferrules used to connect 0.53 mm capillary columns<br />
to wide-bore adapter kit. 1/16 in. fitting. Reverse ferrule<br />
1/16 in. x 0.8 mm i.d. (pkg. 10)<br />
Part No. Each (€)<br />
Wide-Bore Quartz Liner<br />
AutoSystem GC wide-bore<br />
replacement quartz liner.<br />
Wide-Bore Glass Liner<br />
Replacement glass liner (untreated)<br />
for use with the wide-bore adapter<br />
kit (0.53 mm columns).<br />
Part No.<br />
Part No.<br />
Each (€)<br />
09903392 27<br />
Part No.<br />
Each (€)<br />
09920107 84<br />
Part No.<br />
Each (€)<br />
09903739 21<br />
09920141 59<br />
09920107 84<br />
Each (€)<br />
N6121003 32<br />
Part No.<br />
Each (€)<br />
N6101375 29<br />
92
Capillary Column Accessories<br />
Connectors and Supplies<br />
Column Connectors<br />
Union Connectors<br />
Column i.d. (mm) Qty. Part No. Each (€)<br />
0.25* pkg. 10 N9301167 63<br />
0.32* pkg. 10 N9301169 96<br />
pkg. 5 N9301170 129<br />
0.53* pkg. 10 N9301171 63<br />
pkg. 5 N9301172 24<br />
Reducing Connectors<br />
Column i.d. (mm) Qty. Part No. Each (€)<br />
0.32 to 0.25* pkg. 10 N9301338 129<br />
0.53 to 0.25* pkg. 10 N9301340 129<br />
0.53 to 0.32* pkg. 10 N9301342 63<br />
pkg. 5 N9301341 42<br />
* Note: These connectors are not recommended<br />
for use with aluminum-clad columns.<br />
Tools<br />
Pin Vise and Drill Bits<br />
For enlarging ferrule i.d. for capillary columns. Kit includes<br />
a double-ended pin vise and a set of<br />
12 drill bits, sizes No. 61 (0.99 mm)<br />
through No. 80 (0.343 mm).<br />
Part No.<br />
N9301346<br />
Each (€)<br />
51<br />
Pin Vise and Drill Bit Kit Part No. N9301346<br />
Uncoated Deactivated<br />
Fused-Silica Capillary Tubing<br />
High-quality, uncoated fusedsilica<br />
tubing is available in<br />
standard capillary sizes.<br />
Deactivated tubing is perfect for<br />
making guard columns and<br />
replacement Transfer Lines in HS<br />
and TD samplers retention gaps;<br />
available in 5 m lengths. Use our<br />
SPLITTERS and CONNECTORS<br />
to attach tubing to your<br />
polyimide-coated columns.<br />
Polyimide-Uncoated Deactivated Tubing<br />
Tube i.d. (mm) Length Part No. Each (€)<br />
0.10 5 m N9301355 114<br />
0.18 5 m N9301354 75<br />
0.25 5 m N9301356 37<br />
0.32 5 m N9301357 37<br />
0.53 5 m N9301358 63<br />
Capillary Column Support for PerkinElmer GCs<br />
Column supports delicate fused-silica columns<br />
in the proper oven location for optimum<br />
chromatographic performance.<br />
Description Part No. Each (€)<br />
AutoSystem Series/Clarus N6101070 51<br />
Universal Connectors<br />
Allows for fast, leak-free connections of fused-silica<br />
columns. The new fused-silica tapered design allows<br />
connection of any size column and it’s easy to use.<br />
(0.1 to 0.53 mm columns can be used.)<br />
Description Part No. Each (€)<br />
Polyimide Sealing Resin* (5 g) N9301343 39<br />
Universal Connector* (pkg. 5) N9302149 81<br />
Universal Y Splitter* (pkg. 1) N9303448 96<br />
* Note: These connectors are not recommended<br />
for use with aluminum-clad columns.<br />
Universal Connector<br />
Part No. N9302149<br />
Capillary Column Accessories Gas Chromatography<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
93
Capillary Column Accessories<br />
Ferrules<br />
Gas Chromatography Capillary Column Accessories<br />
Graphite and Vespel Ferrules<br />
Graphite Ferrules<br />
This is the ferrule of choice for high-temperature<br />
applications. Of the three ferrule types available, graphite<br />
is the softest, making it less damaging to capillary columns<br />
when overtightened. Graphite seals easily and does not<br />
stick to glass columns. Recommended for use with capillary<br />
columns. Temperature limit is 450 °C.<br />
Nut Size (in.) Ferrule i.d. (in.) Qty. Part No. Each (€)<br />
1/16 1/16 pkg. 10 02450972 55<br />
1/8 1/8 pkg. 10 09903915 54<br />
1/4 1/4 pkg. 10 09920140 43<br />
Graphite/Vespel Ferrules<br />
Graphite/vespel ferrules (15% graphite/85% polyimide) are<br />
recommended for use with GC/MS systems. Best choice for<br />
glass columns and polyimide-coated, fused-silica capillary<br />
columns. Can usually be removed easily from column.<br />
Temperature limit is 350 °C.<br />
Nut Size (in.) Ferrule i.d. (in.) Qty. Part No. Each (€)<br />
1/16 1/16 pkg. 10 09920127 84<br />
1/8 1/8 pkg. 1 N9302081 84<br />
1/4 1/4 pkg. 10 09903739 21<br />
Vespel Packed Stainless Steel Column Ferrules<br />
Vespel ferrules are not reusable; they tend to stick to<br />
columns after use at upper temperature limit. Not<br />
recommended for fused-silica capillary columns. Use these<br />
vespel ferrules on 1/16 in. metal tubing and glass-lined<br />
receivers (heated or ambient). Temperature limit is 350 °C.<br />
Nut Size (in.) Ferrule i.d. (in.) Qty. Part No. Each (€)<br />
1/8 1/8 pkg. 10 N9301360 64<br />
1/4 1/4 pkg. 10 N9301361 65<br />
Capillary Column Ferrules<br />
Package quantity: 10<br />
Nut Size Column Ferrule Graphite Graphite/Vespel<br />
(in.) i.d. (mm) i.d.(mm) Part No. Each (€) Part No. Each (€)<br />
1/16 0.18-0.25 0.4 N/A 09920104 84<br />
1/16 0.32 0.5 09903700 48 09920105 84<br />
1/16 0.32 0.5 (2-hole) N9306001 55 N9306000 110<br />
1/16 0.53 0.8 09920141 59 09920107 84<br />
1/16 0.18-0.25 0.4 (2-hole) N/A 04972392 19<br />
1/8 0.53 1.0 09903394 48 N/A<br />
1/8 0.32 0.5 (2-hole) 09903395 75 N/A<br />
1/8 0.32 0.5 09903981 48 N/A<br />
Note: 0.25-0.32 mm i.d. columns require 0.5 mm i.d. ferrules;<br />
0.53 mm i.d. columns require 0.8 mm i.d. ferrules.<br />
SilTite Metal Ferrules Nut and Ferrules Kit<br />
SilTite Metal Nut and<br />
Ferrules provide a continuous<br />
leak-free connection and are<br />
perfect for connecting<br />
your column to a GC/MS.<br />
From the SilTite drawing it<br />
can be seen that the taper of the inner nut is designed<br />
specifically for the angle of the SilTite ferrule. This ensures<br />
an even closure of the ferrule around the whole column to<br />
eliminate leaks.<br />
Features and Benefits:<br />
■ No need to re-tighten the nut<br />
■ Eliminate contamination<br />
■ Reusable nut<br />
■ Leak-free seal<br />
■ Starter kit contains 2 SilTite nuts and 10 ferrules<br />
The metal SilTite ferrule and nut are manufactured from<br />
the same material and will therefore not expand and contract<br />
at different coefficient rates. The base of the SilTite ferrule<br />
forms a perfect seal with the MS interface, covering the<br />
whole transfer interface. SilTite metal ferrules have a<br />
temperature limit well above the temperature capacity<br />
of the injector, MS interface or GC oven.<br />
Description Qty. Part No. Each (€)<br />
SilTite Ferrules Starter Kit 0.4 mm pkg. 10 N9306090 83<br />
SilTite Ferrules Starter Kit 0.5 mm pkg. 10 N9306091 83<br />
SilTite Ferrules Starter Kit 0.8 mm pkg. 10 N9306092 83<br />
SilTite Ferrules 0.4 mm pkg. 10 N9306093 57<br />
SilTite Ferrules 0.5 mm pkg. 10 N9306094 57<br />
SilTite Ferrules 0.8 mm pkg. 10 N9306095 57<br />
SilTite Nuts pkg. 5 N9306096 70<br />
94
Capillary Column Accessories<br />
Fittings<br />
Swagelok Fittings<br />
Swagelok TM Fittings<br />
Swagelok fittings from PerkinElmer are available in brass and stainless steel.<br />
The patented advanced-geometry back ferrule design provides a leak-tight tube connection on all Swagelok stainless<br />
steel tube fittings, in sizes 1/4 to 1/2 in., and 6 to 12 mm. Leak-tight seals that will withstand high-pressure, vibration,<br />
vacuum and temperature changes depend upon close tolerances and consistent, exacting quality control in conjunction<br />
with good design principles.<br />
Ease of installation<br />
Back ferrule axially advances the front ferrule<br />
Vibration fatigue resistance<br />
Wide variety of configurations<br />
Brass<br />
Stainless Steel<br />
Product Qty. Size Part No. Each (€) Part No. Each (€)<br />
Bulkhead Adapter pkg. 1 1/4 in. to 1/4 in. tube N9301267 48<br />
Back Ferrule pkg. 5 1/16 in. N9300040 12 N9300042 29<br />
1/8 in. N9300036 5 N9300038 17<br />
1/4 in. N9300030 6 N9300032 13<br />
Cross Union pkg. 1 1/8 in. N9301259 40<br />
Front Ferrule pkg. 5 1/16 in. N9300041 12 N9300043 30<br />
1/8 in. N9300037 6 N9300039 19<br />
1/4 in. N9300031 6 N9300033 13<br />
Male Adapter pkg. 1 1/4 in. tube to 1/8 in. NPT N9301266 8<br />
Tube to Pipe<br />
Male Connector pkg. 1 1/8 in. to 1/8 in. NPT N9301253 9<br />
1/8 in. to 1/4 in. NPT N9301254 9<br />
1/4 in. to 1/8 in. NPT N9301255 8<br />
1/4 in. to 1/4 in. NPT N9301269 8<br />
Nut pkg. 5 1/16 in. N9300058 14 N9300059 54<br />
1/8 in. N9300056 9 N9300057 33<br />
1/4 in. N9300054 9 N9300055 30<br />
Plug pkg. 1 1/16 in. N9300053 70<br />
1/8 in. N9300060 9 N9300061 44<br />
1/4 in. N9301268 5 N9301233 17<br />
Union pkg. 2 1/16 in. N9300048 31 N9300049 99<br />
1/8 in. N9300046 25 N9300047 69<br />
1/4 in. N9300044 17<br />
Union Tee pkg. 1 1/16 in. N9301221 37<br />
1/8 in. N9301222 27<br />
1/4 in. N9301223 27<br />
Reducing Union pkg. 1 1/8 in. to 1/16 in. N9300051 27 N9301225 47<br />
1/4 in. to 1/8 in. N9300050 22 N9301226 36<br />
1/4 in. to 1/16 in. N9301227 14<br />
Capillary Column Accessories Gas Chromatography<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
95
Capillary Columns<br />
Application Index<br />
Environmental<br />
Subject Column Page No.<br />
Forensic/Clinical Toxicology<br />
Subject Column Page No.<br />
Gas Chromatography Capillary Columns<br />
Amines and Phenols Elite-5Amine 99<br />
EPA Method 508 – Pesticides Elite-5 99<br />
EPA Method 508 –<br />
Organochlorine Pesticides Elite-CLPesticides 100<br />
Elite-CLPesticides2 100<br />
EPA Method 524.2 Elite-624 (GC/MS) 101<br />
EPA Method 551.1 Elite-5 101<br />
EPA Method 551.1 –<br />
Chlorinated Disinfection Byproducts Elite-200 102<br />
EPA Method 8021 –<br />
Volatile Organics Elite-Volatiles 104<br />
EPA Method 8081 –<br />
Pesticides Elite-35 102<br />
EPA Method 8081A –<br />
Organochlorine Pesticides Elite-CLPesticides 103<br />
Elite-CLPesticides2 103<br />
EPA Method 8260B –<br />
Volatile Organics Elite-VMS 105<br />
EPA Method 8260B –<br />
Volatile Organics Elite-VMS 106<br />
EPA Method 8270 –<br />
Semi-Volatile Organics Elite-5 ms 107<br />
<strong>Essential</strong> Oils –<br />
Citronella Java Oil Elite-1 108<br />
Nitrogen Containing Herbicides Elite-5 108<br />
Pesticides Elite-5 109<br />
Synthetic <strong>Essential</strong> Oil Elite-1 109<br />
Food and Flavors<br />
Subject Column Page No.<br />
Brewing – Beer Elite-BAC 110<br />
<strong>Essential</strong> Oils – Lemon Oil Elite-5 110<br />
<strong>Essential</strong> Oils – Native Spearmint Oil Elite-WAX ETR 111<br />
<strong>Essential</strong> Oils –<br />
Synthetic Mushroom Aroma Elite-WAX ETR 111<br />
Sugars – As Alditol Acetates Elite-225 112<br />
TCA in Wine Elite-5 ms 112<br />
Anabolic Steroids – Underivatized Elite-5 113<br />
Blood Alcohol Elite-BAC 114<br />
Cannabinoids – TMS Derivatives Elite-5 113<br />
Cocaine and Metabolites Elite-5 115<br />
Sympathomimetic Amines –<br />
HFBA Derivatives Elite-5 115<br />
Industrial Chemicals<br />
Subject Column Page No.<br />
Alcohols and Aldehydes Elite-WAX ETR 116<br />
Alcohol Mixtures Elite-WAX ETR 116<br />
Aldehydes Elite-WAX 117<br />
Amines & Phenols Elite-5Amine 117<br />
Aromatics Elite-WAX ETR 118<br />
Industrial Solvents Elite-MWAX 118<br />
Industrial Solvents Elite-WAX ETR 118<br />
Petroleum<br />
Subject Column Page No.<br />
Prudhoe Bay Crude Oil Elite-1GC-79 119<br />
Volatile Hydrocarbons Elite-Q PLOT 119<br />
96
Capillary Columns<br />
U.S. EPA Methods<br />
U.S. EPA Drinking Water<br />
Test Methods<br />
U.S. EPA Organic Chemical<br />
Analysis Waste Water Methods<br />
Method Column Recommendations Part No. Each (€) Method Column Recommendations Part No. Each (€)<br />
501.3 Elite-624 30 m x .53 mm i.d., 3.00 μm N9316207 700 601† Elite-624 30 m x .53 mm i.d., 3.00 μm N9316207 700<br />
Elite-624** 75 m x .53 mm i.d., 3.00 μm N9316208 1249<br />
Elite-624** 75 m x .53 mm i.d., 3.00 μm N9316208 1249<br />
Elite-Volatiles** 30 m x .45 mm i.d., 2.55 μm N9316392 764<br />
Elite-Volatiles** 30 m x .45 mm i.d., 2.55 μm N9316392 764<br />
Elite-Volatiles** 75 m x .45 mm i.d., 2.55 μm N9316393 1274<br />
Elite-Volatiles** 75 m x .45 mm i.d., 2.55 μm N9316393 1274<br />
Elite-502.2 105 m x .53 mm i.d., 3.00 μm N9316190 1210<br />
Elite-502.2 105 m x .53 mm i.d., 3.00 μm N9316190 1210<br />
502.2† Elite-624* 30 m x .53 mm i.d., 3.00 μm N9316207 700 602 Elite-624** 30 m x .53 mm i.d., 3.00 μm N9316207 700<br />
Elite-624** 75 m x .53 mm i.d., 3.00 μm N9316208 1249<br />
Elite-Volatiles** 30 m x .45 mm i.d., 2.55 μm N9316392 764<br />
Elite-Volatiles 30 m x .45 mm i.d., 2.55 μm N9316392 764<br />
Elite-502.2 105 m x .53 mm i.d., 3.00 μm N9316190 1210<br />
Elite-Volatiles** 75 m x .45 mm i.d., 2.55 μm N9316393 1274 603 Elite-624 30 m x .53 mm i.d., 3.00 μm N9316207 700<br />
Elite-502.2 105 m x .53 mm i.d., 3.00 μm N9316190 1210<br />
Elite-Volatiles** 30 m x .45 mm i.d., 2.55 μm N9316392 764<br />
503.1 Elite-624 30 m x .53 mm i.d., 3.00 μm N9316207 700 604 Elite-5ms** 30 m x .53 mm i.d., 1.50 μm N9316300 700<br />
Elite-Volatiles** 30 m x .45 mm i.d., 2.55 μm N9316392 764 606 Elite-1 15 m x .53 mm i.d., 1.50 μm N9316046 356<br />
504 Elite-1* 30 m x .32 mm i.d., 0.25 μm N9316023 547 607 Elite-5 30 m x .53 mm i.d., 1.50 μm N9316100 611<br />
Elite-624** 30 m x .53 mm i.d., 3.00 μm N9316207 700<br />
Elite-5ms** 30 m x .53 mm i.d., 1.50 μm N9316300 700<br />
Elite-Volatiles** 30 m x .45 mm i.d., 2.55 μm N9316392 764 608 Elite-608** 30 m x .53 mm i.d., 0.83 μm N9316197 700<br />
505 Elite-1* 30 m x .32 mm i.d., 1.00 μm N9316024 573 609 Elite-5 30 m x .53 mm i.d., 1.50 μm N9316100 611<br />
Elite-17 30 m x .32 mm i.d., 0.50 μm N9316129 547<br />
Elite-5ms** 30 m x .25 mm i.d., 1.00 μm N9316283 611<br />
507 Elite-5* 30 m x .25 mm i.d., 0.25 μm N9316076 509 610 Elite-5 30 m x .32 mm i.d., 0.25 μm N9316086 573<br />
Elite-5ms** 30 m x .25 mm i.d., 0.25 μm N9316282 611<br />
Elite-5ms** 30 m x .32 mm i.d., 0.25 μm N9316293 636<br />
Elite-1701* 30 m x .25 mm i.d., 0.25 μm N9316234 547 611 Elite-5 15 m x .53 mm i.d., 1.50 μm N9316098 356<br />
508 Elite-5* 30 m x .25 mm i.d., 0.25 μm N9316076 509<br />
Elite-5ms** 15 m x .53 mm i.d., 1.50 μm N9316299 434<br />
Elite-5ms** 30 m x .25 mm i.d., 0.25 μm N9316282 611 612 Elite-1 30 m x .32 mm i.d., 1.00 μm N9316024 573<br />
Elite-608** 30 m x .32 mm i.d., 0.50 μm N9316191 547<br />
Elite-5ms** 30 m x .25 mm i.d., 1.00 μm N9316283 611<br />
Elite-1701* 30 m x .25 mm i.d., 0.25 μm N9316234 547 613 Elite-5ms 60 m x .25 mm i.d., 0.10 μm N9316285 1084<br />
513 Elite-5ms 60 m x .25 mm i.d., 0.10 μm N9316285 1084<br />
Elite-5ms** 60 m x .32 mm i.d., 0.10 μm N9316296 1186<br />
Elite-5ms 60 m x .32 mm i.d., 0.10 μm N9316296 1186 615 Elite-608** 30 m x .53 mm i.d., 0.83 μm N9316197 700<br />
515 Elite-1* 30 m x .32 mm i.d., 0.25 μm N9316023 547<br />
Elite-1701 30 m x .53 mm i.d., 1.00 μm N9316255 740<br />
515.2 Elite-5* 30 m x .32 mm i.d., 0.25 μm N9316086 573 619 Elite-17 30 m x .53 mm i.d., 1.00 μm N9316136 636<br />
Elite-5ms** 30 m x .32 mm i.d., 0.25 μm N9316293 636<br />
Elite-35** 30 m x .53 mm i.d., 1.00 μm N9316152 721<br />
Elite-1701* 30 m x .32 mm i.d., 0.25 μm N9316243 573 622 Elite-5ms** 30 m x .53 mm i.d., 1.50 μm N9316300 700<br />
524.2† Elite-624* 30 m x .25 mm i.d., 1.40 μm N9316201 573 624 Elite-624 30 m x .25 mm i.d., 1.40 μm N9316201 573<br />
Elite-624* 30 m x .53 mm i.d., 3.00 μm N9316207 700<br />
Elite-624 30 m x .53 mm i.d., 3.00 μm N9316207 700<br />
Elite-624* 75 m x .53 mm i.d., 3.00 μm N9316208 1249<br />
Elite-624 75 m x .53 mm i.d., 3.00 μm N9316208 1249<br />
Elite-5* 30 m x .32 mm i.d., 1.00 μm N9316087 547<br />
Elite-Volatiles** 30 m x .45 mm i.d., 2.55 μm N9316392 764<br />
Elite-5ms** 30 m x .25 mm i.d., 1.00 μm N9316283 611<br />
Elite-Volatiles** 75 m x .45 mm i.d., 2.55 μm N9316393 1274<br />
Elite-Volatiles** 30 m x .45 mm i.d., 2.55 μm N9316392 764<br />
Elite-502.2 105 m x .53 mm i.d., 3.00 μm N9316190 1210<br />
Elite-Volatiles** 75 m x .45 mm i.d., 2.55 μm N9316393 1274 625 Elite-5ms** 30 m x .32 mm i.d., 0.25 μm N9316293 636<br />
525 Elite-5* 30 m x .32 mm i.d., 0.25 μm N9316086 573 680 Elite-5* 30 m x .32 mm i.d., 0.25 μm N9316086 573<br />
Elite-5ms** 30 m x .25 mm i.d., 1.00 μm N9316283 611<br />
Elite-5ms** 30 m x .32 mm i.d., 0.25 μm N9316293 636<br />
548.1 Elite-5* 30 m x .25 mm i.d., 0.25 μm N9316076 509 1618 Elite-1 30 m x .53 mm i.d., 1.50 μm N9316050 636<br />
Elite-5* 30 m x .32 mm i.d., 0.25 μm N9316086 573<br />
Elite-608** 30 m x .53 mm i.d., 0.83 μm N9316197 700<br />
Elite-5ms** 30 m x .25 mm i.d., 0.25 μm N9316282 611<br />
Elite-1701 30 m x .53 mm i.d., 1.00 μm N9316255 740<br />
Elite-5ms** 30 m x .32 mm i.d., 0.25 μm N9316293 636 1624 Elite-624 75 m x .45 mm i.d., 2.55 μm N9316206 1249<br />
Elite-Volatiles** 30 m x .45 mm i.d., 2.55 μm N9316392 764<br />
Elite-624** 75 m x .53 mm i.d., 3.00 μm N9316208 1249<br />
551 Elite-1* 30 m x .32 mm i.d., 1.00 μm N9316024 573 1625 Elite-5* 30 m x .25 mm i.d., 0.25 μm N9316076 509<br />
Elite-5ms** 30 m x .25 mm i.d., 1.00 μm N9316283 611<br />
Elite-5ms** 30 m x .25 mm i.d., 0.25 μm N9316282 611<br />
552 Elite-1701* 30 m x .32 mm i.d., 0.25 μm N9316243 573 1653 Elite-5* 30 m x .32 mm i.d., 0.25 μm N9316086 573<br />
* Specified in EPA method.<br />
Elite-5ms** 30 m x .32 mm i.d., 0.25 μm N9316293 636<br />
** This column is highly recommended by PerkinElmer for this EPA method.<br />
† The choice of column for this purge-and-trap method may depend on your<br />
sample concentrator to GC interface.<br />
Capillary Columns Gas Chromatography<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
97
Capillary Columns<br />
U.S. EPA Methods<br />
U.S. EPA Solid Waste<br />
Test Methods<br />
Gas Chromatography Capillary Columns<br />
Method Column Recommendations Part No. Each (€)<br />
8010† Elite-624 75 m x .53 mm i.d., 3.00 μm N9316208 1249<br />
Elite-Volatiles** 75 m x .45 mm i.d., 2.55 μm N9316393 1274<br />
8015 Elite-624 30 m x .53 mm i.d., 3.00 μm N9316207 700<br />
Elite-Volatiles** 30 m x .45 mm i.d., 2.55 μm N9316392 764<br />
8020 Elite-624 30 m x .53 mm i.d., 3.00 μm N9316207 700<br />
Elite-Volatiles** 30 m x .45 mm i.d., 2.55 μm N9316392 764<br />
8030 Elite-624 30 m x .53 mm i.d., 3.00 μm N9316207 700<br />
Elite-Volatiles** 30 m x .45 mm i.d., 2.55 μm N9316392 764<br />
8040 Elite-5ms 30 m x .53 mm i.d., 1.50 μm N9316300 700<br />
8060 Elite-1 15 m x .53 mm i.d., 1.50 μm N9316046 356<br />
8080 Elite-608** 30 m x .53 mm i.d., 0.83 μm N9316197 700<br />
8081 Elite-5* 30 m x .53 mm i.d., 1.50 μm N9316100 611<br />
Elite-608** 30 m x .53 mm i.d., 0.83 μm N9316197 700<br />
Elite-1701* 30 m x .53 mm i.d., 1.00 μm N9316255 740<br />
8090 Elite-5 30 m x .53 mm i.d., 1.50 μm N9316100 611<br />
Elite-5ms** 30 m x .53 mm i.d., 1.50 μm N9316300 700<br />
8100 Elite-5 30 m x .32 mm i.d., 0.25 μm N9316086 573<br />
Elite-5ms** 30 m x .32 mm i.d., 0.25 μm N9316293 636<br />
8120 Elite-1 30 m x .32 mm i.d., 1.00 μm N9316024 573<br />
Elite-5ms** 30 m x .25 mm i.d., 1.00 μm N9316283 611<br />
Elite-5ms** 30 m x .32 mm i.d., 1.00 μm N9316294 636<br />
8140 Elite-1 30 m x .53 mm i.d., 1.50 μm N9316050 636<br />
Elite-1701** 30 m x .53 mm i.d., 1.00 μm N9316255 740<br />
8141 Elite-5* 15 m x .53 mm i.d., 1.50 μm N9316098 356<br />
Elite-5ms** 30 m x .53 mm i.d., 1.50 μm N9316300 700<br />
Elite-35** 30 m x .53 mm i.d., 0.50 μm N9316153 611<br />
8150 Elite-608** 30 m x .53 mm i.d., 0.83 μm N9316197 700<br />
Elite-1701 30 m x .53 mm i.d., 1.00 μm N9316255 740<br />
8240† Elite-624 30 m x .53 mm i.d., 3.00 μm N9316207 700<br />
Elite-624 75 m x .53 mm i.d., 3.00 μm N9316208 1249<br />
Elite-Volatiles** 30 m x .45 mm i.d., 2.55 μm N9316392 764<br />
Elite-Volatiles** 75 m x .45 mm i.d., 2.55 μm N9316393 1274<br />
8250 Elite-5 30 m x .53 mm i.d., 1.50 μm N9316100 611<br />
Elite-5ms** 30 m x .53 mm i.d., 1.50 μm N9316300 700<br />
8260 Elite-5* 30 m x .32 mm i.d., 1.00 μm N9316087 547<br />
Elite-624* 30 m x .53 mm i.d., 3.00 μm N9316207 700<br />
Elite-624 75 m x .53 mm i.d., 3.00 μm N9316208 1249<br />
Elite-Volatiles** 30 m x .45 mm i.d., 2.55 μm N9316392 764<br />
Elite-Volatiles** 75 m x .45 mm i.d., 2.55 μm N9316393 1274<br />
Elite-5ms** 30 m x .25 mm i.d., 1.00 μm N9316283 611<br />
8260B Elite-Volatiles** 30 m x .25 mm i.d., 1.40 μm N9316388 638<br />
8270 Elite-5* 30 m x .32 mm i.d., 1.00 μm N9316087 547<br />
Elite-5ms** 30 m x .25 mm i.d., 0.50 μm N9316284 611<br />
8280 Elite-5* 30 m x .25 mm i.d., 0.25 μm N9316076 509<br />
Elite-5ms** 30 m x .25 mm i.d., 1.00 μm N9316283 611<br />
* Specified in EPA method.<br />
** This column is highly recommended by PerkinElmer for this EPA method.<br />
† The choice of column for this purge-and-trap method may depend on your<br />
sample concentrator to GC interface.<br />
98
Capillary Column Applications<br />
Environmental<br />
Amines and Phenols<br />
U.S. EPA Method 508 – Pesticides<br />
1. Etridiazole (50 pg/μL)<br />
2. Chlorneb (1000 pg/μL)<br />
3. Propachlor (1000 pg/μL)<br />
4. Trifluralin (50 pg/μL)<br />
5. a-BHC (20 pg/μL)<br />
6. Hexachlorobenzene (10 pg/μL)<br />
7. b-BHC (20 pg/μL)<br />
8. g-BHC (30 pg/μL)<br />
9. PCNB (impurity) (100 pg/μL)<br />
10. PCNB (IS) (100 pg/μL)<br />
11. d-BHC (20 pg/μL)<br />
12. Chlorothalonil (50 pg/μL)<br />
13. Heptachlor (20 pg/μL)<br />
14. Aldrin (30 pg/μL)<br />
15. DCPA (50 pg/μL)<br />
16. DCB (SS) (5000 pg/μL)<br />
17. Heptachlor Epoxide (30 pg/μL)<br />
18. g-Chlordane (30 pg/μL)<br />
19. Endosulfan I (30 pg/μL)<br />
20. a-Chlordane (30 pg/μL)<br />
Column: Elite-5<br />
Dimensions: 30 m, 0.25 mm i.d., 0.25 μm<br />
Sample: 2.0 μL splitless injection of a pesticide mix<br />
Splitless Hold: 0.75 min.<br />
Oven Temperature: 60 °C to 300 °C @ 4 °C/min.<br />
(hold 10 min.)<br />
Injector: 250 °C<br />
Detector: ECD, 320 °C<br />
Carrier Gas: Helium @ 30 cm/sec.<br />
Part No.<br />
1<br />
2<br />
3<br />
N9316076<br />
4<br />
5<br />
6<br />
7<br />
8<br />
9<br />
10<br />
11<br />
2 4 6 8 10<br />
TIME (MIN.)<br />
12<br />
21. Dieldrin (40 pg/μL)<br />
22. Endrin (30 pg/μL)<br />
23. Endosulfan II (30 pg/μL)<br />
24. Chlorobenzilate (1000 pg/μL)<br />
25. P, P'-DDD (50 pg/μL)<br />
26. Endrin Aldehyde (50 pg/μL)<br />
27. Endosulfan Sulfate (30 pg/μL)<br />
28. P, P'-DDD (120 pg/μL)<br />
29. Methoxychlor (100 pg/μL)<br />
30. cis-Permethrin (1000 pg/μL)<br />
31. trans-Permethrin (1000 pg/μL)<br />
13<br />
1<br />
2 3<br />
4<br />
6<br />
7<br />
4 8 12 16 20 24 28 32 36 40 44 48 52<br />
5<br />
TIME (MIN.)<br />
9 10<br />
8<br />
1. Diethylamine<br />
2. Pyridine<br />
3. Morpholine<br />
4. Phenol<br />
5. Aniline<br />
6. 2-Chlorophenol<br />
7. Diethylenetriamine<br />
8. Octylamine<br />
9. 1-Methyl-2-Pyrrolidinone<br />
10. 2-Nitrophenol<br />
11. 2, 6-Dimethylaniline<br />
12. Nicotine<br />
13. 2-Nitroaniline<br />
Column: Elite-5Amine<br />
Dimensions: 30 m, 0.32 mm i.d., 1.0 μm<br />
Sample: 1.0 μL split injection of<br />
miscellaneous amines<br />
and phenols in water<br />
On-Column Conc.: 22 ng<br />
Oven: 120 °C to 220 °C @ 10 °C/min.<br />
Injector & Detector: 305 °C<br />
Carrier Gas: Hydrogen<br />
Linear Velocity: 38 cm/sec. set @ 120 °C<br />
FID Sensitivity: 6.4 x 10-11 AFS<br />
Split Ratio: 25:1<br />
Part No.<br />
12<br />
16<br />
21<br />
14<br />
15<br />
17<br />
11 19<br />
18<br />
13<br />
N9316677<br />
20 22<br />
26<br />
28<br />
24 25<br />
23<br />
27<br />
29<br />
30 31<br />
Capillary Column Applications Gas Chromatography<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
99
Capillary Column Applications<br />
Environmental<br />
Gas Chromatography Capillary Column Applications<br />
U.S. EPA Method 508 – Organochlorine Pesticides<br />
1<br />
2<br />
3<br />
6 8 10 12 14 16 18 20<br />
TIME (MIN.)<br />
Column: Elite-CLPesticides<br />
Dimensions: 30 m, 0.32 mm i.d., 0.50 μm,<br />
Elite-CLPesticides (N9316664)<br />
Dimensions: 30 m, 0.32 mm i.d., 0.25 μm,<br />
Elite-CLPesticides2 (N9316662)<br />
EPA 508.1 list w/added compounds<br />
Oven: 120 °C (hold 1 min.) to 300 °C @ 9 °C/min.<br />
(hold 10 min.)<br />
Injector: Direct, Uniliner ® inlet liner, 200 °C<br />
Dead Time: 1.797 (Elite-CLPesticides),<br />
1.663 (Elite-CLPesticides2)<br />
Head Pressure: 12 psi (constant)<br />
Carrier Gas: Helium<br />
Flow: 2.1 mL/min. @ 120 °C<br />
Part No.<br />
Part No.<br />
10,11,12<br />
4<br />
5,6<br />
7<br />
8,9<br />
14<br />
13<br />
N9316664<br />
N9316662<br />
15<br />
18,19<br />
16,<br />
17<br />
24,25<br />
22<br />
23<br />
26 28<br />
27 32<br />
20,<br />
21<br />
31<br />
30<br />
29<br />
33<br />
34<br />
35<br />
36<br />
37<br />
38<br />
1<br />
1. Hexachloropentadiene<br />
2. Etridiazole<br />
3. Chlorneb<br />
4. Hexachlorobenzene<br />
5. Propachlor<br />
6. a-BHC<br />
7. Simazine<br />
8. g-BHC<br />
9. Atrazine<br />
10. Trifluralin<br />
11. Pentachloronitrobenzene<br />
12. b-BHC<br />
13. d-BHC<br />
14. Metribuzin<br />
15. Heptachlor<br />
16. Aldrin<br />
17. Chlorothalonil<br />
18. 4, 4'-Dibromobiphenyl<br />
19. Alachlor<br />
2<br />
3<br />
10<br />
5<br />
4 6<br />
8,11 1317<br />
9<br />
7<br />
12<br />
20. Metalachlor<br />
21. DCPA (Dacthal ® )<br />
22. Heptachlor Epoxide<br />
23. g-Chlordane<br />
24. Cyanazine<br />
25. a-Chlordane<br />
26. 4, 4'-DDE<br />
27. Endosulfan I<br />
28. Dieldrin<br />
29. Endrin<br />
30. Chlorobenzilate<br />
31. 4, 4'-DDD<br />
32. Endosulfan II<br />
33. 4, 4'-DDT<br />
34. Endrin Aldehyde<br />
35. Methoxychlor<br />
36. Endosulfan Sulfate<br />
37. cis-Permethrin<br />
38. trans-Permethrin<br />
6 8 10 12 14 16 18 20<br />
TIME (MIN.)<br />
14<br />
16<br />
18,21<br />
24<br />
19<br />
20<br />
22<br />
25 26 27<br />
23<br />
28<br />
31<br />
29,<br />
30<br />
32<br />
33<br />
34<br />
36<br />
35<br />
37<br />
38<br />
100
Capillary Column Applications<br />
Environmental<br />
U.S. EPA Method 524.2<br />
Column: Elite-624 (GC/MS)<br />
Dimensions: 75 m, 0.53 mm i.d., 3.0 μm<br />
Sample: 20 ppm of 502.2 Standards Calibration Mixes 1-6<br />
Oven: 35 °C (hold 8 min.) to 220 °C at 10 °C/min. (hold 3 min.)<br />
Detector: MS, 250 °C<br />
Scan Range: 45-300AMU<br />
Purge: 11 min.<br />
Purge and Trap: Tenax, Silica Gel, charcoal<br />
Desorb Preheat: 220 °C, 2 min. desorb at 225 °C<br />
Desorb Flow Rate: 10 mL/min.<br />
Part No.<br />
Standards used are 524 Volatiles Kit:<br />
1. Dichlorodifluoromethane<br />
2. Chloromethane<br />
3. Vinyl Chloride<br />
4. Bromomethane<br />
5. Chloroethane<br />
6. Trichlorofluoromethane<br />
7. 1, 1-Dichloroethene<br />
8. Methylene Chloride<br />
9. trans-1, 2-Dichloroethene<br />
10. 1, 1-Dichloroethane<br />
11. cis-1, 2-Dichloroethene<br />
12. 2, 2-Dichloropropane<br />
13. Bromochloromethane<br />
14. Chloroform<br />
15. 1, 1, 1-trichloroethane<br />
16. Carbon Tetrachloride<br />
U.S. EPA Method 551.1<br />
1<br />
N9316208<br />
2<br />
3<br />
4<br />
5<br />
6<br />
7<br />
8<br />
1 3<br />
2<br />
17. 1, 1-Dichloropropene<br />
18. Benzene<br />
19. 1, 2-Dichloroethane<br />
20. Trichloroethene<br />
21. 1, 2-Dichloropropane<br />
22. Dibromomethane<br />
23. Bromodichloromethane<br />
24. cis-1, 3-Dichloropropene<br />
25. Toluene<br />
26. trans-1, 3-Dichloropropene<br />
27. 1, 1, 2-Trichloroethane<br />
9<br />
10<br />
11<br />
6<br />
4<br />
5<br />
10 20 30<br />
TIME (MIN.)<br />
14<br />
12<br />
13<br />
15<br />
7<br />
8 9<br />
10<br />
11,12 13 14<br />
15<br />
28. Tetrachloroethene<br />
29. 1, 3-Dichloropropane<br />
30. Dibromochloromethane<br />
31. 1, 2-Dibromoethane<br />
32. Chlorobenzene<br />
33. 1, 1, 1, 2-tetrachloroethane<br />
34. Ethylbenzene<br />
35. m-Xylene<br />
36. p-Xylene<br />
37. o-Xylene<br />
38. Styrene<br />
16,17 18<br />
19<br />
33,34<br />
25<br />
28 32<br />
20<br />
22<br />
30<br />
27<br />
23 24 31<br />
21 26<br />
29<br />
35,36<br />
37,38<br />
39. Bromoform<br />
40. Isopropylbenzene<br />
41. Bromobenzene<br />
42. 1, 1, 2, 2-Tetrachloroethane<br />
43. 1, 2, 3-Trichloropropane<br />
44. Propylbenzene<br />
45. 2-Chlorotoluene<br />
46. 1, 3, 5-Trimethylbenzene<br />
47. 4-Chlorotoluene<br />
48. tert-Butylbenzene<br />
49. 1, 2, 4-Trimethylbenzene<br />
43,44<br />
41,42 54<br />
50<br />
53<br />
40<br />
46 49<br />
48<br />
55<br />
47<br />
5 10 15 20 25<br />
TIME (MIN.)<br />
16<br />
17<br />
18<br />
1. Chloroform<br />
2. 1, 1, 1-Trichloroethane<br />
3. Carbon Tetrachloride<br />
4. Trichloroacetonitrile<br />
5. Trichloroethylene<br />
6. Bromodichloromethane<br />
7. Chloral Hydrate<br />
8. Dichloroacetonitrile<br />
9. 1, 1-Dichloro-2-Propanone<br />
10. 1, 1, 2-Trichloroethane<br />
11. Chloropicrin<br />
19<br />
20<br />
21<br />
39<br />
45<br />
51,52<br />
56<br />
57<br />
58<br />
59 60<br />
50. sec-Butylbenzene<br />
51. 1, 3-Dichlorobenzene<br />
52. p-Isopropyltoluene<br />
53. 1, 4-Dichlorobenzene<br />
54. n-Butylbenzene<br />
55. 1, 2-Dichlorobenzene<br />
56. 1, 2-Dibromo-3-Chloropropane<br />
57. 1, 2, 4-Trichlorobenzene<br />
58. Hexachlorobutadiene<br />
59. Naphthalene<br />
60. 1, 2, 3-Trichlorobenzene<br />
12. Dibromochloromethane<br />
13. 1, 2-Dibromoethane (EDB)<br />
14. Tetrachloroethylene<br />
15. Bromochloroacetonitrile<br />
16. 1, 1, 1-trichloro-2-propanone<br />
17. Bromoform<br />
18. Dibromoacetonitrile<br />
19. 1, 2, 3-Trichloropropane<br />
20. 4-Bromofluorobenzene (I.S.)<br />
21. 1,2-Dibromo-3-Chloropropane (DBCP)<br />
Column: Elite-5<br />
Dimensions: 30 m, 0.25 mm i.d., 1.0 μm<br />
Sample: 1.0 μL split injection, 1 ng on-column concentration<br />
Oven: 35 °C (hold 22 min.) to 200 °C at 10 °C/min.<br />
Injector: 200 °C<br />
Detector: ECD, 290 °C<br />
Carrier: Helium at 30 cm/sec.<br />
Split Ratio: 10:1<br />
Part No.<br />
N9316077<br />
Capillary Column Applications Gas Chromatography<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
101
Capillary Column Applications<br />
Environmental<br />
Gas Chromatography Capillary Column Applications<br />
U.S. EPA Method 551.1 – Chlorinated Disinfection Byproducts<br />
1<br />
3<br />
U.S. EPA Method 8081 – Pesticides<br />
Column: Elite-35<br />
Dimensions: 30 m, 0.32 mm i.d., 0.50 μm<br />
Oven Temperature: 120 °C (hold 1 min.) to 285 °C<br />
@ 8.5 °C/min. (hold 6 min.)<br />
Injector: 200 °C<br />
Detector: ECD, 300 °C<br />
Carrier Gas: Helium<br />
Part No.<br />
2<br />
5,6<br />
4<br />
12<br />
8, 14<br />
7 9<br />
N9316147<br />
10<br />
11,13<br />
1. 2,4,5,6-tetrachloro-m-xylene<br />
2. a-BHC<br />
3. g-GHC (lindane)<br />
4. b-BHC<br />
5. d-BHC<br />
6. Heptachlor<br />
7. Aldrin<br />
8. Heptachlor Epoxide<br />
9. g-Chlordane<br />
10. a-Chlordane<br />
11. 4,4'-DDE<br />
17<br />
10 20 30<br />
15<br />
16<br />
12. Endosulfan I<br />
13. Dieldrin<br />
14. Endrin<br />
15. 4,4'-DDT<br />
16. Endosulfan II<br />
17. 4,4'-DDD<br />
18. Endrin Aldehyde<br />
19. Methoxychlor<br />
20. Endosulfan Sulfate<br />
21. Endrin Ketone<br />
22. Decachlorobiphenyl<br />
18,19<br />
20<br />
1<br />
1. Chloroform<br />
2. 1,1,1-Trichloroethane<br />
3. Carbon Tetrachloride<br />
4. Trichloroacetonitrile<br />
5. Trichloroethylene<br />
6. Bromodichloromethane<br />
7. Chloral Hydrate<br />
8. Dichloroacetonitrile<br />
9. 1,1-Dichloro-2-Propanone<br />
10. 1,1, 2-Trichloroethane<br />
11. Chloropicrin<br />
21<br />
2<br />
3<br />
4<br />
6<br />
5<br />
7<br />
8<br />
9<br />
10<br />
12<br />
11<br />
12 15 18 21 24<br />
13<br />
TIME (MIN.)<br />
12. Dibromochloromethane<br />
13. 1, 2-Dibromoethane (EDB)<br />
14. Tetrachloroethylene<br />
15. Bromochloroacetonitrile<br />
16. 1,1,1-Trichloro-2-Propanone<br />
17. Bromoform<br />
18. Dibromoacetonitrile<br />
19. 1, 2, 3-Trichloropropane<br />
20. 4-Bromofluorobenzene (IS)<br />
21. 1, 2-Dibromo-3-Chloropropane (DBCP)<br />
Column: Elite-200<br />
Dimensions: 30 m, 0.25 mm i.d., 1.0 μm<br />
Sample: 1.0 μL split injection,<br />
1 ng on-column concentration<br />
Oven: 35 °C (hold 22 min.) to 200 °C<br />
@ 10 °C/min.<br />
Injector/Detector: 200 °C/290 °C<br />
Carrier Gas: Helium<br />
Linear Velocity: 30 cm/sec. @ 50 °C<br />
ECD Sensitivity: 20 kHz full scale<br />
Split Ratio: 10:1<br />
TIME (MIN.) Part No. N9316623<br />
16<br />
17<br />
18<br />
14 15<br />
20<br />
19<br />
21<br />
22<br />
102
Capillary Column Applications<br />
Environmental<br />
U.S. EPA Method 8081A – Organochlorine Pesticides<br />
1<br />
1<br />
2<br />
2<br />
3<br />
6,7<br />
4 8<br />
9<br />
10<br />
11 12<br />
16<br />
15<br />
14<br />
13<br />
17 19<br />
20,22<br />
10 15 20 25<br />
TIME (MIN.)<br />
3<br />
5<br />
4<br />
5<br />
6<br />
7<br />
8<br />
9<br />
10<br />
12<br />
11<br />
21<br />
23<br />
24<br />
25<br />
10 15 20 25<br />
TIME (MIN.)<br />
20<br />
13<br />
14<br />
16<br />
15<br />
18<br />
23<br />
17<br />
19<br />
18<br />
22<br />
21<br />
24<br />
26<br />
27<br />
28<br />
26<br />
25 27<br />
28<br />
29<br />
29<br />
1. Dibromochloropropane<br />
2. Hexachlorocyclopentadiene<br />
3. 2, 4, 5, 6-Tetrachloro-m-Xylene<br />
4. Hexachlorobenzene<br />
5. cis-Diallate<br />
6. a-BHC<br />
7. trans-Diallate<br />
8. g-BHC<br />
9. b-BHC<br />
10. d-BHC<br />
11. Heptachlor<br />
12. Aldrin<br />
13. Isodrin<br />
14. Heptachlor Epoxide<br />
15. g-Chlordane<br />
16. a-Chlordane<br />
17. 4, 4'-DDE<br />
18. Endosulfan I<br />
19. Dieldrin<br />
20. Chlorobenzilate<br />
21. Endrin<br />
22. 4,4'-DDD<br />
23. Endosulfan II<br />
24. 4, 4'-DDT<br />
25. Endrin Aldehyde<br />
26. Methoxychlor<br />
27. Endosulfan Sulfate<br />
28. Endrin Ketone<br />
29. Decachlorobiphenyl<br />
Column: Elite-CLPesticides and<br />
Elite-CLPesticides2<br />
Dimensions: 30 m, 0.32 mm i.d., 0.50 μm,<br />
Elite-CLPesticides (N9316664)<br />
Dimensions: 30 m, 0.32 mm i.d., 0.25 μm,<br />
Elite-CLPesticides2 (N9316670)<br />
On-Column Conc.: 16–160 pg<br />
Oven: 80 °C (hold 1 min.) to 300 °C @ 10 °C/min.<br />
(hold 15 min.)<br />
Injector: Direct, Uniliner ® inlet liner<br />
Detector: ECD, 300 °C, with Anode Purge<br />
Dead Time: 1.9 min.<br />
Head Pressure: 8.7 psi (constant)<br />
Flow Rate: Helium @ 1.3 mL/min. @ 120 °C<br />
Part No.<br />
Part No.<br />
N9316664<br />
N9316670<br />
Capillary Column Applications Gas Chromatography<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
103
Capillary Column Applications<br />
Environmental<br />
Gas Chromatography Capillary Column Applications<br />
U.S. EPA Method 8021 – Volatile Organics<br />
Column: Elite-Volatiles<br />
Dimensions: 20 ppb in 5 mL of RO Water. 75 m, 0.45 mm i.d., 2.55 μm<br />
Concentrator: Purge and Trap<br />
Trap: Vocarb 3000<br />
Purge: 11 min. at 40 mL/min.<br />
Dry Purge: 1 min. at 40 mL/min. (MCS bypassed with Silcosteel tubing)<br />
Desorb Preheat: 245 °C<br />
Desorb: 250 °C for 2 min.<br />
Bake: 260 °C for 8 min.<br />
Interface: direct<br />
Transfer Line: 0.32 mm i.d.<br />
Oven: 35 °C (hold 12 min.) to 60 °C at 5 °C/min. (hold 1 min.) to 220 °C at 17 °C/min.<br />
(hold 3 min.)<br />
Carrier: Helium at 9 mL/min.<br />
Detectors: PID/ELCD<br />
PID: makeup 7 mL/min., purge 7 mL/min., set at 0.35 mV base temp 200 °C<br />
ELCD: Reaction Gas 25mL/min.<br />
Reaction Temp.: 940 °C, propanol flow 470 μL/min.<br />
Part No.<br />
PID<br />
3<br />
7<br />
N9316393<br />
1. Dichlorodifluoromethane<br />
2. Chloromethane<br />
3. Vinyl Chloride<br />
4. Bromomethane<br />
5. Chloroethane<br />
6. Trichlorofluoromethane<br />
7. 1, 1-Dichloroethene<br />
8. Methylene Chloride<br />
9. Freon ® 113<br />
10. trans-1, 2-Dichloroethene<br />
11. Methyl-tert-Butyl-Ether<br />
12. 1, 1-Dichloroethane<br />
13. cis-1, 2-Dichloroethene<br />
14. Bromochloromethane<br />
15. Chloroform<br />
16. 2, 2-Dichloropropane<br />
17. 1, 2-Dichloroethane<br />
18. 1, 1, 1-Trichloroethane<br />
19. 1, 1-Dichloropropene<br />
20. Carbon Tetrachloride<br />
21. Benzene<br />
22. Fluorobenzene<br />
23. Dibromomethane<br />
24. 1, 2-Dichloropropane<br />
25. Trichloroethene<br />
26. Bromodichloromethane<br />
27. 2-Chloroethylvinylether<br />
28. cis-1, 3-Dichloropropene<br />
29. trans-1, 3-Dichloropropene<br />
30. 1, 1, 2-Trichloroethane<br />
10<br />
13<br />
11<br />
31. Toluene<br />
32. 1, 3-Dichloropropane<br />
33. Dibromochloromethane<br />
34. 1, 2-Dibromoethane<br />
35. Tetrachloroethene<br />
36. 1, 1, 1, 2-Tetrachloroethane<br />
37. Chlorobenzene<br />
38. Ethyl Benzene<br />
39. m-Xylene<br />
40. p-Xylene<br />
41. Bromoform<br />
42. Styrene<br />
43. 1, 4-Dichlorobutane<br />
44. 1,1, 2, 2-Tetrachloroethane<br />
45. o-Xylene<br />
46. 1, 2, 3-Trichloropropane<br />
47. Isopropyl Benzene<br />
48. Bromobenzene<br />
49. n-Propyl Benzene<br />
50. 2-Chlorotoluene<br />
51. 4-Chlorotoluene<br />
52. 1, 3, 5-Trimethylbenzene<br />
53. tert-Butylbenzene<br />
54. 1, 2, 4-Trimethylbenzene<br />
55. sec-Butylbenzene<br />
56. 1, 3-Dichlorobenzene<br />
57. 1, 4-Dichlorobenzene<br />
58. p-Isopropyl Toluene<br />
59. 1, 2-Dichlorobenzene<br />
60. n-Butylbenzene<br />
19<br />
21<br />
22 25 27 28 29<br />
5 10 15 20 25<br />
31<br />
35<br />
61. 1, 2-Bromo-3-Chloropropane<br />
62. 4-Bromo-1-Chlorobenzene<br />
63. 1, 2, 4-Trichlorobenzene<br />
64. Naphthalene<br />
65. Hexachlorobutadiene<br />
66. 1, 2, 3-Trichlorobenzene<br />
63 64<br />
66<br />
65<br />
ELCD<br />
TIME (MIN.)<br />
7<br />
3<br />
5<br />
1 2 6<br />
4<br />
37<br />
38<br />
39/40<br />
42<br />
45<br />
47<br />
48<br />
51<br />
50<br />
49<br />
52<br />
53<br />
55 56<br />
54<br />
57<br />
58 59 60<br />
22.5 25.0 27.5<br />
8<br />
9<br />
10<br />
15<br />
12<br />
13<br />
14<br />
20<br />
16 17<br />
18<br />
19<br />
enlarged<br />
view from<br />
PID<br />
22<br />
26<br />
24<br />
23<br />
5 10 15 20 25<br />
25<br />
29<br />
28<br />
33<br />
27<br />
34<br />
62<br />
35 36<br />
57<br />
63<br />
66<br />
56<br />
59<br />
30<br />
32 37<br />
44<br />
50 51<br />
46<br />
43<br />
41 48<br />
62<br />
61<br />
65<br />
104
Capillary Column Applications<br />
Environmental<br />
U.S. EPA Method 8260B – Volatile Organics<br />
73-75<br />
76<br />
77,78<br />
11.5 11.6 11.7 11.8 11.9 12.0 12.1 12.2 12.3 12.4 12.5 12.6 12.7 12.8 12.9 13.0<br />
TIME (MIN.)<br />
1. Carbon Dioxide<br />
2. Dichlorodifluoromethane<br />
3. Freon ® 114<br />
4. Chloromethane<br />
5. Vinyl Chloride<br />
6. Bromomethane<br />
7. Chloroethane<br />
8. Trichlorofluoromethane<br />
9. Ethanol<br />
10. Diethyl Ether<br />
11. 1,1-Dichloroethene<br />
12. Lodomethane<br />
13. Carbon Disulfide<br />
14. Freon ® 113<br />
15. Acrolein<br />
16. Allyl Chloride<br />
17. Methylene Chloride<br />
18. Acetone<br />
19. trans-1,2-Dichloroethene<br />
20. Methyl Acetate<br />
21. Methyl tert-Butyl Eether<br />
22. tert-Butyl Alcohol<br />
79 80<br />
Column: Elite-VMS<br />
Dimensions: 40 m, 0.18 mm i.d., 1.0 μm<br />
Conc.: 5 ppb each in 25 mL of RO water<br />
Trap: Vocarb 3000<br />
Purge: 11 min. @ 40 mL/min.<br />
Dry Purge: 1 min. @ 40 mL/min. (MCS by-passed<br />
with Silcosteel ® Tubing)<br />
Desorb Preheat: 245 °C<br />
Desorb: 2 min. @ 250 °C<br />
Desorb Flow Rate: 45 mL/min. Helium<br />
Bake: 8 min. @ 260 °C<br />
Interface: Plumbed through injection port<br />
Part No.<br />
N9316651<br />
81<br />
82<br />
83<br />
2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0 10.0 11.0 12.0 13.0 14.0 15.0<br />
TIME (MIN.)<br />
23. Acetonitrile<br />
24. Diisopropyl Ether<br />
25. Chloroprene<br />
26. 1,1-Dichloroethane<br />
27. Acrylonitrile<br />
28. Vinyl Acetate**<br />
29. Ethyl-tert-Butyl Ether**<br />
30. cis-1, 2-Dichloroethene<br />
31. 2, 2-Dichloropropane<br />
32. Bromochloromethane<br />
33. Chloroform<br />
34. Carbon Tetrachloride<br />
35. Ethyl Acetate<br />
36. Methyl Acrylate<br />
37. Dibromofluoromethane<br />
38. Tetrahydrofuran<br />
39. 1,1,1-Trichloroethane<br />
40. 2-Butanone<br />
41. 1,1-Dichloropropene<br />
42. Benzene<br />
43. Propionitrile<br />
44. Methacrylonitrile<br />
45. Pentafluorobenzene<br />
46. tert-Amyl-Methyl Ether<br />
47. 1, 2-Dichloroethane<br />
48. Isobutyl Alcohol<br />
49. Isopropyl Acetate<br />
50. Trichloroethene<br />
51. 1, 4-Difluorobenzene<br />
52. Dibromomethane<br />
53. 1, 2-Dichloropropane<br />
54. Bromodichloromethane<br />
55. Methyl Methacrylate<br />
56. n-Propyl Acetate<br />
57. 2-Chloroethyl Vinyl Ether<br />
58. cis-1, 3-Dichloropropene<br />
59. Toluene-d8<br />
60. Toluene<br />
61. 2-Nitropropane<br />
62. Tetrachloroethene<br />
63. 4-Methyl-2-Pentanone<br />
64. trans-1, 3-Dichloropropene<br />
65. 2-Bromo-1-Chloropropane<br />
66. 1,1, 2-Trichloroethane<br />
* 2-Chloroethanol in 8260B mix requires lower scan range for identification;<br />
1, 4-Dioxane requires fortification or identification using single-point high-calibration standard.<br />
** Peaks 28 & 29 share ion (43).<br />
84<br />
86-89<br />
85<br />
90-92<br />
93<br />
94<br />
96,97<br />
95<br />
98 99 100<br />
101,102<br />
103<br />
60<br />
59<br />
49 50 58 6972<br />
45<br />
42,43 51<br />
28,29 35-38 46 54 53<br />
40,41<br />
55 57 68 71<br />
70<br />
1<br />
11-13<br />
2 3 5 4<br />
6 7 8 16 17 21<br />
19 20 24 25,26<br />
44<br />
30 31 33 39<br />
47 52 56<br />
10<br />
32 34<br />
14 18<br />
61<br />
9 15 22 23 27<br />
48<br />
104<br />
Transfer Line: Silcosteel ® transfer line<br />
Mount Temperature: 40 °C<br />
Split Ratio: 1:40 split<br />
Injector: 250 °C<br />
Carrier Gas: 1.1 mL/min. Helium, constant flow<br />
Linear Velocity: 32 cm/sec. @ 40 °C<br />
Oven: 35 °C (hold 2 min.) to 60 °C @ 4 °C/min.<br />
(hold 0 min.) to 225 °C @ 40 °C/min.<br />
(hold 5 min.)<br />
Source Temperature: 280 °C<br />
Scan Range: 35–260 amu<br />
Ionization: EI<br />
62-64<br />
66,67<br />
65<br />
67. Ethyl Methacrylate<br />
68. Dibromochloromethane<br />
69. 1, 3-Dichloropropane<br />
70. 1, 2-Dibromoethane<br />
71. n-Butyl Acetate<br />
72. 2-Hexanone<br />
73. Chlorobenzene-d5<br />
74. Chlorobenzene<br />
75. Ethylbenzene<br />
76. 1,1,1, 2-Tetrachloroethane<br />
77. m-Xylene<br />
78. p-Xylene<br />
79. o-Xylene<br />
80. Styrene<br />
81. Bromoform<br />
82. Isopropylbenzene<br />
83. n-Amyl Acetate<br />
84. 4-Bromo-1-Fluorobenzene (ss)<br />
85. cis-1,4-Dichloro-2-Butene<br />
86. n-Propylbenzene<br />
87. Bromobenzene<br />
88. 1, 4-Dichlorobutane<br />
108<br />
106,107 109 110<br />
105<br />
89. 1,1, 2, 2-Tetrachloroethane<br />
90. 2-Chlorotoluene<br />
91. 1, 3, 5-Trimethylbenzene<br />
92. 1, 2, 3-Trichloropropane<br />
93. trans-1, 4-Dichloro-2-Butene<br />
94. 4-Chlorotoluene<br />
95. tert-Butylbenzene<br />
96. Pentachloroethane<br />
97. 1, 2, 4-Trimethylbenzene<br />
98. sec-Butylbenzene<br />
99. p-Isopropyltoluene<br />
100. 1, 3-Dichlorobenzene<br />
101. 1, 4-Dichlorobenzene-d4<br />
102. 1, 4-Dichlorobenzene<br />
103. n-Butylbenzene<br />
104. 1, 2-Dichlorobenzene<br />
105. 1, 2-Dibromo-3-Chloropropane<br />
106. Nitrobenzene<br />
107. Hexachlorobutadiene<br />
108. 1, 2, 4-Trichlorobenzene<br />
109. Naphthalene<br />
110. 1, 2, 3-Trichlorobenzene<br />
Capillary Column Applications Gas Chromatography<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
105
Capillary Column Applications<br />
Environmental<br />
Gas Chromatography Capillary Column Applications<br />
U.S. EPA Method 8260B – Volatile Organics<br />
Column: Elite-Volatiles<br />
Dimensions: 30 m, 0.25 mm i.d., 1.40 μm<br />
Conc.: TurboMatrix 110 Headspace Trap<br />
Trap: Air Monitoring<br />
Thermostating Time: 80 °C<br />
Needle Temperature: 90 °C<br />
Dry Purge: 5 min.<br />
Desorb Temperature: 280 °C<br />
Desorb Time: 0.5 min.<br />
Oven Temperature: 40 °C (hold 2 min.) to 100 °C @ 10 °C/min. (hold 0 min.)<br />
to 240 °C @ 30 °C/min. (hold 5 min.)<br />
Carrier Gas: Helium at 1 mL/min.<br />
Detector: MS<br />
Scan Time: 0.10 sec.<br />
Transfer Line Temperature: 200 °C<br />
Source Temperature: 200 °C<br />
Trap Emission: 75 μA<br />
Part No.<br />
N9316388<br />
1. Dichlorodifluoromethane<br />
2. Chloromethane<br />
3. Vinyl Chloride<br />
4. Bromomethane<br />
5. Chloroethane<br />
6. Trichlorofluoromethane<br />
7. Ethanol (2500 ppb)<br />
8. 1,1-Dichloroethene<br />
9. Carbon Disulfide (40 ppb)<br />
10. Allyl Chloride<br />
11. Methylene Chloride<br />
12. Acetone<br />
13. trans-1, 2-Dichloroethene<br />
14. Methyl tert-Butyl Ether<br />
15. tert-Butyl Alcohol (100 ppb)<br />
16. Disopropyl Ether<br />
17. 1,1-Dichloroethane<br />
18. Acrylonitrile<br />
19. Vinyl Acetate<br />
20. Allyl Alcohol (250 ppb)<br />
21. Ethyl-tert-Buyl Ether<br />
22. cis-1, 2-Dichloroethene<br />
23. 2, 2-Dichloropropane<br />
24. Bromochloromethane<br />
25. Chloroform<br />
26. Ethyl Acetate<br />
27. Carbon Tetrachloride<br />
28. Methyl Acrylate<br />
29. Propargyl Alcohol (500 ppb)<br />
30. Dibromofluoromethane (SMC)<br />
31. Tetrahydrofuran<br />
32. 1,1,1-Trichloroethane<br />
33. 2-Butanone<br />
34. 1,1-Dichloropropene<br />
35. Benzene<br />
36. Pentafluorobenzene (IS)<br />
37. tert-Amyl-Methyl Ether<br />
38. 1, 2-Dichloroethane<br />
39. Isobutyl Alcohol (500 ppb)<br />
40. Isopropyl Acetate<br />
41. Trichloroethene<br />
42. 1, 4-Difluorobenzene (SMC)<br />
43. Dibromomethane<br />
44. 1, 2-Dichloropropane<br />
45. Bromodichloromethane<br />
46. Methyl Methacrylate<br />
47. n-Propyl Acetate<br />
48. 2-Chloroethanol (2500 ppb)<br />
49. cis-1, 3-Dichloropropene<br />
50. Toluene-d8 (SMC)<br />
TIME (MIN.)<br />
51. Toluene<br />
52. Pyridine (250 ppb)<br />
53. Tetrachloroethene<br />
54. 4-Methyl-2-Pentanone<br />
55. trans-1, 3-Dichloropropene<br />
56. 1,1, 2-Trichloroethane<br />
57. Ethyl Methacrylate<br />
58. Dibromochloromethane<br />
59. 1, 3-Dichloropropane<br />
60. 1, 2-Dibromoethane<br />
61. n-Butyl Acetate<br />
62. 2-Hexanone<br />
63. 2-Picoline (250 ppb)<br />
64. Chlorobenzene-D5 (IS)<br />
65. Chlorobenzene<br />
66. Ethylbenzene<br />
67. 1,1,1, 2-Tetrachloroethane<br />
68. m-Xylene<br />
69. p-Xylene<br />
70. o-Xylene<br />
71. Stryrene<br />
72. Bromoform<br />
73. Isopropylbenzene<br />
74. 4-Bromo-1-Fluorobenzene (SMC)<br />
75. Bromobenzene<br />
76. n-Propylbenzene<br />
77. 1,1, 2, 2-Tetrachloroethane<br />
78. 2-Chlorotoluene<br />
79. 1, 3, 5-Trimethylbenzene<br />
80. 1, 2, 3-Trichloropropane<br />
81. 4-Chlorotoluene<br />
82. tert-Butylbenzene<br />
83. Pentachloroethane<br />
84. 1, 2, 4-Trimethylbenzene<br />
85. sec-Butylbenzene<br />
86. p-Isopropyltoluene<br />
87. 1, 3-Dichlorobenzene<br />
88. 1, 4-Dichlorobenzene-d4 (IS)<br />
89. 1, 4-Dichlorobenzene<br />
90. n-Butylbenzene<br />
91. 1, 2-Dichlorobenzene<br />
92. 1, 2-Dibromo-3-Chloropropane<br />
93. Nitrobenzene (250 ppb)<br />
94. Hexachlorobutadiene<br />
95. 1, 2, 4-Trichlorobenzene<br />
96. Naphthalene<br />
97. 1, 2, 3-Trichlorobenzene<br />
106
Capillary Column Applications<br />
Environmental<br />
U.S. EPA Method 8270 – Semi-Volatile Organics<br />
6,7<br />
1,2<br />
8<br />
10,11<br />
1. n-Nitrosodimethylamine<br />
2. Pyridine<br />
3. Methyl Methanesulfonate<br />
4. 2-Fluorophenol<br />
5. Ethyl Methanesulfonate<br />
6. Phenol-d6<br />
7. Phenol<br />
8. Aniline<br />
9. Bis(2-chloroethyl)ether<br />
10. 2-Chlorophenol-d4<br />
11. 2-Chlorophenol<br />
12. 1, 3-Dichlorobenzene<br />
13. 1, 4-Dichlorobenzene-d4<br />
14. 1, 4-Dichlorobenzene<br />
15. Benzyl Alcohol<br />
16. 1, 2-Dichlorobenzene-d4<br />
17. 1, 2-Dichlorobenzene<br />
18. 2-Methylphenol<br />
9<br />
3<br />
4<br />
13,14<br />
12<br />
5<br />
16,17<br />
15<br />
18<br />
19<br />
6,7<br />
10<br />
20 21,22<br />
23 24<br />
25 26<br />
27,28<br />
34<br />
29,30<br />
47<br />
31<br />
32<br />
19. Bis(2-chloroisopropyl)ether<br />
20. 4-Methylphenol/<br />
3-Methylphenol<br />
21. n-Nitroso-di-n-Propylamine<br />
22. Acetophenone<br />
23. Hexachloroethane<br />
24. Nitrobenzene-d5<br />
25. Nitrobenzene<br />
26. Isophorone<br />
27. 2, 4-Dimethylphenol<br />
28. 2-Nitrophenol<br />
29. Benzoic Acid<br />
30. Bis (2-Chloroethoxy) Methane<br />
31. 2, 4-Dichlorophenol<br />
32. 1, 2, 4-Trichlorobenzene<br />
33. Naphthalene-d8<br />
34. Naphthalene<br />
35. 2, 6-Dichlorophenol<br />
33<br />
34<br />
58<br />
38<br />
67<br />
35,36<br />
37<br />
39<br />
81<br />
40<br />
82<br />
86<br />
83<br />
87,88<br />
84<br />
41 42<br />
44<br />
43<br />
85<br />
36. 4-Chloroaniline<br />
37. Hexachloropropene<br />
38. Hexachlorobutadiene<br />
39. 4-Chloro-3-Methylphenol<br />
40. Isosafrole<br />
41. 2-Methylnaphthalene<br />
42. 1-Methylnaphthalene<br />
43. Hexachlorocyclopentadiene<br />
44. 1 ,2, 4, 5-Tetrachlorobenzene<br />
45. 2, 4, 6-Trichlorophenol<br />
46. 2, 4, 5-Trichlorophenol<br />
47. 2-Fluorobiphenyl<br />
48. Safrole<br />
49. 2-Chloronaphthalene<br />
50. 2-Nitroaniline<br />
51. 1, 4-Naphthoquinone<br />
52. Dimethylphthalate<br />
53. 1, 3-Dinitrobenzene<br />
45<br />
47<br />
46<br />
89<br />
90 91<br />
95,96 97<br />
98<br />
48<br />
49<br />
92<br />
94<br />
93<br />
5051 52 53<br />
54<br />
55<br />
59<br />
57<br />
58<br />
60<br />
54. 2, 6-Dinitrotoluene<br />
55. Acenaphthylene<br />
56. 3-Nitroaniline<br />
57. Acenaphthene-d10<br />
58. Acenaphthene<br />
59. 2, 4-Dinitrophenol<br />
60. 4-Nitrophenol<br />
61. Pentachlorobenzene<br />
62. 2,4-Dinitrotoluene<br />
63. Dibenzofuran<br />
64. 2, 3, 4, 6-Tetrachlorophenol<br />
65. Diethyl Phthalate<br />
66. 4-Chlorophenyl Phenyl Ether<br />
67. Fluorene<br />
68. 4-Nitroaniline<br />
69. 4,6-Dinitro-2-Methylphenol<br />
70. Diphenylamine<br />
71. Azobenzene<br />
61<br />
99 100 101<br />
102<br />
103<br />
62,63<br />
64<br />
66<br />
65<br />
67 68,69<br />
70 71 72<br />
72. 2, 4, 6-Tribromophenol<br />
73. Phenacetin<br />
74. 4-Bromophenyl-Phenyl ether<br />
75. Hexachlorobenzene<br />
76. Pentachlorophenol<br />
77. Pentachloronitrobenzene<br />
78. Dinoseb<br />
79. Phenanthrene-d10<br />
80. Phenanthrene<br />
81. Anthracene<br />
82. Di-n-Butylphthalate<br />
83. 4-Nitroquinoline-1-Oxide<br />
84. Isodrin<br />
85. Fluoranthene<br />
86. Benzidine<br />
87. Pyrene<br />
88. Aromite<br />
89. p-Terphenyl-d14<br />
104,105 106<br />
4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24<br />
80 81<br />
74 75<br />
73 77<br />
79<br />
76<br />
78<br />
7.0 7.5 8.0 8.5 9.0 9.5 10.0 10.5 11.0 11.5 12.0 12.5<br />
TIME (MIN.)<br />
Column: Elite-5 ms<br />
Dimensions: 30 m, 0.25 mm i.d., 0.5 μm<br />
Sample: 80 ng splitless injection of CLP standard<br />
Oven: 40 °C (hold 2 min.) to 290 °C at 20 °C/min.<br />
(hold 0 min.) to 303 °C at 2 °C/min. (hold<br />
0 min.) to 330 °C at 6 °C/min. (hold 1 min.)<br />
Injector: 300 °C<br />
Detector: MS, 280 °C, scan range 35-550 AMU<br />
Carrier: Helium at 1.0 mL/min.<br />
Part No.<br />
N9316284<br />
90. Chlorbenzilate<br />
91. Butyl Benzyl Phthalate<br />
92. Kepone<br />
93. Bis(2-ethylhexyl)phthalate<br />
94. 3, 3'-Dichlorobenzidine<br />
95. Benzo (a) Anthracene<br />
96. Chrysene-d12<br />
97. Chrysene<br />
98. Di-n-Octyl Phthalate<br />
99. Benzo (k) Fluoranthene<br />
100. Benzo (b) Fluoranthene<br />
101. Benzo (a) Pyrene<br />
102. Perylene-d12<br />
103. 3-Methylcholanthrene<br />
104. Indeno (1, 2, 3-cd) Pyrene<br />
105. Dibenzo (a, h) Snthracene<br />
106. Benzo (g, h ,i) Perylene<br />
Capillary Column Applications Gas Chromatography<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
107
Capillary Column Applications<br />
Environmental<br />
Gas Chromatography Capillary Column Applications<br />
<strong>Essential</strong> Oils – Citronella Java Oil<br />
1. Limonene<br />
2. Citronellal<br />
3. Linalool<br />
4. Borneol<br />
5. γ-Elemene<br />
6. β-Caryophyllene<br />
7. Neryl Acetate<br />
8. α-Terpineol<br />
9. Germancrene-Δ<br />
10. β-Citronellol<br />
11. Geranyl Acetate<br />
12. δ-Cadenene<br />
13. Nerol<br />
14. Geraniol<br />
15. Eugenol<br />
16. α-Bergamotene<br />
1<br />
3<br />
2<br />
4<br />
8<br />
10<br />
13<br />
14<br />
15<br />
7<br />
11<br />
5<br />
TIME (MIN.)<br />
6<br />
Column: Elite-1<br />
Dimensions: 60 m, 0.25 mm i.d., 0.25 μm<br />
Sample: 1.0 μL split injection of Citronella Java Oil<br />
Oven: 100 °C to 260 °C at 4 °C/min. (hold 1 min.)<br />
Injector: 250 °C<br />
Detector: MS, 280 °C<br />
Carrier: Helium at 30 cm/sec.<br />
Split Vent: 100 cc/min.<br />
Part No.<br />
9<br />
12<br />
16<br />
N9316013<br />
6 8 10 12 14 16 18 20 22 24 26 28<br />
Nitrogen Containing Herbicides<br />
1. Eptam ®<br />
2. Sutan ®<br />
3. Vernam ®<br />
4. Tillam ®<br />
5. Ordram ®<br />
6. Propachlor<br />
7. Ro-Neet ®<br />
8. Treflan ®<br />
9. Balan ®<br />
10. Simazine<br />
11. Atrazine<br />
1<br />
12. Propazine<br />
13. Tolban ®<br />
14. Terbacil<br />
15. Sencor ®<br />
16. Bromacil<br />
17. Dual ®<br />
18. Paarlan ®<br />
19. Prowl ®<br />
20. Oxadiazon<br />
21. GOAL ®<br />
22. Hexazinone<br />
2<br />
3<br />
4<br />
5<br />
6 7<br />
2 4 6 8 10 12 14 16 18<br />
TIME (MIN.)<br />
9<br />
8<br />
12<br />
11<br />
10<br />
13<br />
15<br />
14<br />
16<br />
17 19<br />
18<br />
Column: Elite-5<br />
Dimensions: 30 m, 0.53 mm i.d., 5.0 μm<br />
Sample: 0.2 μL direct injection of nitrogen containing herbicides.<br />
Concentration approximately 10 ng per component.<br />
Oven Temperature: 60 °C (hold 1 min.) to 290 °C @ 15 °C/min.<br />
(hold 5 min.)<br />
Injector: 290 °C<br />
Detector: FID, 290 °C<br />
Carrier Gas: Helium @ 40 cm/sec.<br />
Part No.<br />
20 21<br />
22<br />
N9316102<br />
108
Capillary Column Applications<br />
Environmental<br />
Pesticides<br />
1. Tetrachloro-m-xylene<br />
2. a-BHC<br />
3. g-BHC<br />
4. Heptachlor<br />
5. Aldrin<br />
6. b-BHC<br />
7. d-BHC<br />
8. Heptachlor Epoxide<br />
Synthetic <strong>Essential</strong> Oil Mixture<br />
3,4<br />
20,21<br />
14<br />
27<br />
19<br />
23,24<br />
18<br />
6,7 15<br />
28<br />
22<br />
2<br />
16<br />
1 5 25<br />
8<br />
11,12<br />
10 9 13 26<br />
17<br />
9. Endosulfan I<br />
10. g-Chlordane<br />
11. a-Chlordane<br />
12. P, P'-DDE<br />
13. Dieldrin<br />
14. Endrin<br />
15. P, P'-DDD<br />
16. Endosulfan II<br />
Column: Elite-5<br />
Dimensions: 30 m, 0.53 mm i.d., 5.0 μm<br />
Sample: 1.0 μL direct injection of a pesticide mix.<br />
Concentration: 80-800 ppb (ng/mL)<br />
Oven Temperature: 150 °C (hold 5 min.) to 275 °C<br />
@ 4 °C/min. (hold 5 min.)<br />
Injector: 200 °C<br />
Detector: ECD, 275 °C<br />
Carrier Gas: Helium @ 40 cm/sec.<br />
Part No.<br />
N9316102<br />
29 31<br />
30<br />
35<br />
32,33<br />
34<br />
36<br />
37<br />
38<br />
10 15 20 25 30<br />
TIME (MIN.)<br />
39<br />
1<br />
40<br />
17. P, P'-DDT<br />
18. Endrin Aldehyde<br />
19. Endosulfan Sulfate<br />
20. Methoxychlor<br />
21. Endrin Ketone<br />
22. Decachlorobiphenyl<br />
41<br />
2 3<br />
6<br />
7 4<br />
42<br />
5 8<br />
9<br />
10 11<br />
TIME (MIN.)<br />
13 12 14<br />
16<br />
17<br />
19<br />
15<br />
18<br />
10 20 30<br />
1. Ethyl Butyrate<br />
2. trans-2-Hexenol<br />
3. α-Pinene<br />
4. Benzaldehyde<br />
5. Camphene<br />
6. Octanol<br />
7. β-Myrcene<br />
8. β-Pinene<br />
9. α-Phellandrene<br />
10. p-Cymene<br />
11. l-Limonene<br />
12. Camphor<br />
13. trans-Sabinene Hydrate<br />
14. Linalool<br />
15. Citronellal<br />
16. l-Menthone<br />
17. Menthofuran<br />
18. l-Menthol<br />
19. α-Terpineol<br />
20. Linalyl Acetate<br />
21. β-Citronellol<br />
22. Nerol<br />
23. Carveol<br />
24. Anisaldehyde<br />
25. Carvone<br />
26. Geraniol<br />
27. Anethole<br />
28. Cinnamic Alcohol<br />
29. Eugenol<br />
30. Neryl Acetate<br />
31. Geranyl Acetate<br />
32. Vanillin<br />
33. Coumarin<br />
34. α-Ionone<br />
35. Ethyl Vanillin<br />
36. β-Caryophyllene<br />
37. α-Caryophyllene<br />
38. β-Ionone<br />
39. Valencene<br />
40. Ethyl Laurate<br />
41. Amyl Cinnamic Aldehyde<br />
42. Nootketone<br />
Column: Elite-1<br />
Dimensions: 60 m, 0.25 mm i.d., 0.25 μm<br />
Sample: 1.0 μL split injection of 42 flavor components<br />
Oven: 100 °C to 260 °C at 4 °C/min. (hold 1 min.)<br />
Injector: 250 °C<br />
Detector: 280 °C<br />
Carrier: Helium at 30 cm/sec.<br />
Split Vent: 100 cc/min.<br />
Part No.<br />
21<br />
N9316013<br />
20<br />
22<br />
Capillary Column Applications Gas Chromatography<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
109
Capillary Column Applications<br />
Food and Flavors<br />
Gas Chromatography Capillary Column Applications<br />
180<br />
160<br />
140<br />
120<br />
100<br />
80<br />
60<br />
40<br />
20<br />
Brewing – Beer<br />
1. Chloroform<br />
2. 2, 3-Butanedione (Diacetyl)<br />
3. 2, 3-Pentanedione<br />
1<br />
2<br />
0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 2.6 2.8 3.0 3.2 3.4 3.6 3.8<br />
TIME (MIN.)<br />
<strong>Essential</strong> Oils – Lemon Oil<br />
2 3 5<br />
6<br />
7,8<br />
13<br />
12<br />
14 15<br />
17<br />
26<br />
TIME (MIN.)<br />
3<br />
Column: Elite BAC-1<br />
Dimensions: 30 m x 0.32 mm x 1.8 μm<br />
Instrument: Headspace TurboMatrix 40<br />
Table 2: HS Conditions<br />
Sample Temperature: 60 °C<br />
Needle Temperature: 80 °C<br />
Transfer Line Temperature: 100 °C<br />
Equilibration Time: 15 min.<br />
Pressurization Time: 1.0 min.<br />
Injection Time: 0.1 min.<br />
Withdrawal Time: 0.0 min.<br />
Carrier Pressure: 35 psi<br />
Table 3: GC with ECD Conditions<br />
Initial Temperature: 45 °C<br />
Time 1: 1.3 min.<br />
Rate 1: 40 °C/min.<br />
Final Temperature: 150 °C<br />
Hold: 0.6 min<br />
Injector Temperature: 100 °C<br />
Liner: Zero Dilution<br />
Split: 25 mL/min.<br />
ECD: 150 °C<br />
ECD Attenuation: 1<br />
Makeup Gas (Argon/Methane) 30 mL/min.<br />
Part No.<br />
10<br />
4 9<br />
20<br />
11<br />
21 22<br />
27,28<br />
1819<br />
23 24 25<br />
31<br />
30<br />
34<br />
1<br />
37<br />
16<br />
2 4 6 8 10 12 14 16 18 20 22 24 26 28<br />
1. Heptanol<br />
2. α-Thujene<br />
3. α-Pinene<br />
4. Camphene<br />
5. Sabinene<br />
6. β-Pinene<br />
7. 6-Methyl-5-Hepten-2-One<br />
8. Myrcene<br />
9. Octanal<br />
10. α-Phellandrene<br />
11. 3-Carene<br />
12. α-Terpinene<br />
13. π-Cymene<br />
14. Limonene<br />
15. γ-Terpinene<br />
16. Octanol<br />
29<br />
17. Terpinolene<br />
18. Linalool<br />
19. Nonanal<br />
20. Citronellal<br />
21. Terpinen-4-ol<br />
22. α-Terpineol<br />
23. Decanol<br />
24. Octyl Acetate<br />
32<br />
33<br />
35<br />
36<br />
38<br />
25. Nerol<br />
26. Neral<br />
27. Carvone<br />
28. Geraniol<br />
29. Geranial<br />
30. Nonyl Acetate<br />
31. Citronellyl Acetate<br />
32. Neryl Acetate<br />
N9316579<br />
Column: Elite-5<br />
Dimensions: 30 m, 0.32 mm i.d., 0.25 μm<br />
Sample: Wet needle split injection of<br />
a neat lemon oil<br />
Oven: 75 °C (hold 8 min.) to 250 °C<br />
at 4 °C/min.<br />
Injector: 250 °C<br />
Detector: FID, 250 °C<br />
Carrier: Hydrogen at 40 cm/sec.<br />
Split Ratio: 100:1<br />
Part No.<br />
N9316086<br />
33. Geranyl Acetate<br />
34. Dodecanal<br />
35. β-Caryophyllene<br />
36. trans-α-Bergamotene<br />
37. α-Humulene<br />
38. β-Bisabolene<br />
110
Capillary Column Applications<br />
Food and Flavors<br />
<strong>Essential</strong> Oils – Native Spearmint Oil<br />
1 2<br />
1. α-Pinene<br />
2. β-Pinene<br />
3. Sabinene<br />
4. Myrcene<br />
5. α-Terpinene<br />
6. L-Limonene<br />
<strong>Essential</strong> Oils – Synthetic Mushroom Aroma<br />
1. Acetone<br />
2. Ethyl Acetate<br />
3. Methylene Chloride<br />
4. Hexanal<br />
5. Amyl Acetate<br />
6. 1-Butanol<br />
7. 3-Methyl-1-Butanol<br />
8. 1-Pentanol<br />
9. 3-Octanone<br />
10. 3-Octanol<br />
11. Nonanal<br />
12. 1-Octen-3-ol<br />
13. Furfural<br />
14. Benzaldehyde<br />
15. Octyl Alcohol<br />
16. Phenylacetaldehyde<br />
17. α-Terpineol<br />
18. 2, 4-Nonadienal<br />
19. 2, 4-Decadienal<br />
20. Benzyl Alcohol<br />
3<br />
4 67<br />
5<br />
13<br />
12<br />
9<br />
8<br />
10 11<br />
1<br />
2<br />
3<br />
14<br />
15<br />
16<br />
4<br />
17<br />
5<br />
6<br />
18<br />
19<br />
20<br />
7<br />
21<br />
22<br />
8<br />
9<br />
23<br />
24<br />
26 27 28<br />
4 6 8 10 12 14 16 18 20 22 24 26 28 30 32<br />
TIME (MIN.)<br />
7. 1, 8-Cineole<br />
8. cis-Ocimene<br />
9. γ-Terpinene<br />
10. p-Cymene<br />
11. Terpinolene<br />
12. 3-Octyl Acetate<br />
25<br />
13. 3-Octanol<br />
14. L-Menthone<br />
15. trans-Sabinenehydrate<br />
16. β-Bourbonene<br />
17. Linalool<br />
18. Terpinene-4-ol<br />
10<br />
11<br />
12<br />
2 4 6 8 10 12 14 16 18 20 22 24 26 28 30<br />
TIME (MIN.)<br />
29<br />
13<br />
Column: Elite-WAX ETR<br />
Dimensions: 60 m, 0.25 mm i.d., 0.25 μm<br />
Sample: 0.2 μL split injection of a neat spearmint oil<br />
Oven: 75 °C (hold 4 min.) to 200 °C at<br />
4 °C/min. (hold 10 min.)<br />
Injector: 250 °C<br />
Detector: FID, 250 °C<br />
Carrier: Hydrogen at 40 cm/sec.<br />
Split Ratio: 100:1<br />
30<br />
19. β-Caryophyllene<br />
20. Dihydrocarvone<br />
21. trans-Dihydrocarvyl Acetate<br />
22. trans-β-Farnesene<br />
23. α-Terpineol<br />
24. Germacrene-Δ<br />
14<br />
15<br />
16<br />
Column: Elite-WAX ETR<br />
Dimensions: 30 m, 0.32 mm i.d., 1.0 μm<br />
Sample: 1.0 μL split injection of a synthetic mushroom aroma,<br />
concentration 10 ng per component<br />
Oven: 40 °C to 220 °C at 6 °C/min.<br />
Injector: 260 °C<br />
Detector: FID, 260 °C<br />
Carrier: Hydrogen at 40 cm/sec.<br />
Split Ratio: 100:1<br />
Part No.<br />
Part No.<br />
N9316557<br />
17<br />
18<br />
N9316551<br />
25. Carvone<br />
26. cis-Carvyl Acetate<br />
27. trans-Carveol<br />
28. cis-Carveol<br />
29. cis-Jasmone<br />
30. Viridiflorol<br />
19<br />
20<br />
Capillary Column Applications Gas Chromatography<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
111
Capillary Column Applications<br />
Food and Flavors<br />
Gas Chromatography Capillary Column Applications<br />
Sugars – As Alditol Acetates<br />
TCA in Wine<br />
TCA 12127<br />
100<br />
%<br />
0<br />
2<br />
1<br />
4<br />
3<br />
TIME (MIN.)<br />
78<br />
5 6<br />
2.5 5 7.5 10 12.5<br />
1. Natural Wine Separation Products<br />
2. TCA<br />
1<br />
1<br />
2<br />
SIR of 2 Channels El+<br />
TIC<br />
35166<br />
1<br />
1<br />
1<br />
1. Rhamnitol<br />
2. Fucitol<br />
3. Ribitol<br />
4. Arabinitol<br />
5. Mannitol<br />
6. Galactitol<br />
7. Glucitol<br />
8. Inositol<br />
Column: Elite-225<br />
Dimensions: 15 m, 0.25 mm i.d., 0.25 μm<br />
Sample: 0.5 μL split injection of alditol<br />
acetate derivatives<br />
Oven: 190 °C (hold 5 min.) to 250 °C<br />
at 8 °C/min. (hold 5 min.)<br />
Injector: 260 °C<br />
Detector: 260 °C<br />
Carrier: Helium at 42 cm/sec.<br />
Split Ratio: 50:1<br />
Part No.<br />
N9316175<br />
Column: Elite-5ms<br />
Dimensions: 30 m x 0.25 mm x 0.25 μm<br />
Instrument: Clarus 500 GC/MS<br />
Oven: 50 °C (hold 4 min.) to 240 °C at<br />
40 °C/min. (hold 5 min.)<br />
Injector: 150 °C<br />
Carrier: Helium (99.999%)<br />
Instrument: TurboMatrix Headspace<br />
HS-40 Trap<br />
Needle Temperature: 75 °C<br />
Transfer Line Temperature: 75 °C<br />
Oven Temperature: 75 °C<br />
Trap Low Temperature: 40 °C<br />
Trap High Temperature: 280 °C<br />
Dry Purge Time: 5 min.<br />
Trap Hold Time: 5 min.<br />
Desorb Pressure Time: 0 min.<br />
Thermostatting Time: 30 min.<br />
Pressurization: 1 min., 3 cycles<br />
Decay Time: 1.2 min.<br />
Vial Pressure: 40 psi<br />
Column Pressure: 25 psi<br />
Trap Sorbent: CarboPack Y<br />
Part No.<br />
4.49 4.69 4.89 5.09 5.29 5.49 5.69 5.89 6.09 6.29 6.49 6.69 6.89 7.09 7.29 7.49 7.69 7.89 8.09<br />
TIME (MIN.)<br />
N9316282<br />
112
Capillary Column Applications<br />
Forensics/Clinical Toxicology<br />
Anabolic Steroids – Underivatized<br />
Cannabinoids – TMS Derivatives<br />
10,11<br />
1<br />
3<br />
5 13<br />
8 14<br />
7 9<br />
6<br />
2<br />
15<br />
4<br />
12 16<br />
18<br />
17<br />
2 4 6 8 10 12 14 16 18<br />
TIME (MIN.)<br />
Column: Elite-5<br />
Dimensions: 15 m, 0.25 mm i.d., 0.25 μm<br />
Sample: 1.0 μL splitless injection of cannabinoids,<br />
concentration 100 μg/mL<br />
Oven: 50 °C (hold 0.5 min.) to 225 °C at 30 °C/min.,<br />
to 325 °C at 10 °C/min.<br />
Injector: 225 °C<br />
Detector: MS, 320 °C<br />
Carrier: Helium at 40 cm/sec.<br />
Splitless Hold Time: 0.75 min.<br />
Scan Range: 40-500 AMU<br />
Part No.<br />
N9316073<br />
1. Cannabidiol<br />
2. Δ 8 -Tetrahydrocannabinol<br />
3. Δ 9 -Tetrahydrocannabinol<br />
4. Cannibinol<br />
5. 11-Hydroxy-Δ 9 -Tetrahydrocannabinol<br />
6. 11-Nor-Δ 9 -Tetrahydrocannabinol Carboxylic Acid<br />
7. 11-Nor-Δ 8 -Tetrahydrocannabinol Carboxylic Acid<br />
1<br />
Column: Elite-5<br />
Dimensions: 30 m, 0.25 mm i.d., 0.10 μm<br />
Sample: 0.5 μL split injection of anabolic steroids<br />
Concentration 1000 ng/μL<br />
Oven: 180 °C to 340 °C at 10 °C/min. (hold 3 min.)<br />
Injector: 280 °C<br />
Detector: FID, 340 °C<br />
Carrier: Helium at 35 cm/sec.<br />
Split Ratio: 50:1<br />
5 6 7 8 9 10 11 12 13 14 15<br />
TIME (MIN.)<br />
19<br />
Part No.<br />
2<br />
3<br />
4<br />
N9316075<br />
1. 5-Androstene-3β,17β-diol<br />
2. 17α-Methyl-5-Androstene-3β,17β-Diol<br />
3. 5α-Androstan-17β-ol-3-One<br />
4. 19-Nortestosterone<br />
5. 17α-Methylandrostan-17β-ol-3-One<br />
6. Mesterolone<br />
7. Testosterone<br />
8. 17α-Methyltestosterone<br />
9. 1-Dehydrotestosterone<br />
10. 1-Dehydro-17α-Methyltestosterone<br />
11. Bolasterone<br />
12. Oxymethalone<br />
13. 19-Nortestosterone-17-Propionate<br />
14. Testosterone Propionate<br />
15. Fluoxymesterone<br />
16. 4-Chlorotestosterone-17-Acetate<br />
17. Testosterone-17β-Cypionate<br />
18. 1-Dehydrotestosterone Benzoate<br />
19. 1-Dehydrotestosterone Undecylenate<br />
5<br />
6<br />
7<br />
Capillary Column Applications Gas Chromatography<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
113
Capillary Column Applications<br />
Forensics/Clinical Toxicology<br />
Gas Chromatography Capillary Column Applications<br />
Blood Alcohol<br />
1<br />
Blood Alcohol<br />
1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 2.6 2.8 3.0<br />
TIME (MIN.)<br />
1<br />
2<br />
2<br />
3<br />
4<br />
3<br />
4<br />
5<br />
5<br />
6<br />
1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 2.6 2.8 3.0<br />
TIME (MIN.)<br />
6<br />
Column: Elite-BAC-1<br />
Dimensions: 30 m x 0.32 mm x 1.8 μm<br />
Sample: 1.0 mL Blood Alcohol Mix<br />
Oven: 40 °C Isothermal<br />
Injector: 200 °C<br />
Carrier: Helium<br />
Sample Equilibration Temperature: 70 °C<br />
Sample Equilibration Time: 15 min.<br />
Vial Pressure: 30 psi<br />
Vial Pressurization Time: 0.15 min.<br />
Vial Sampling Time: 0.01 min.<br />
Transfer Line: 0.32 mm i.d. FS Hydroguard TM Tubing (N9301357)<br />
Transfer Line Temperature: 200 °C<br />
Injection Port Sleeve: 2 mm i.d.<br />
Split Flow: 20 mL per min.<br />
Part No.<br />
N9316579<br />
Conc. w/v<br />
1. Methanol 0.1%<br />
2. Acetaldehyde 0.2%<br />
3. Ethanol 0.2%<br />
4. Isopropanol 0.1%<br />
5. Acetone 0.01%<br />
6. n-Propanol 0.1%<br />
Column: Elite-BAC-2<br />
Dimensions: 30 m x 0.32 mm x 1.2 μm<br />
Sample: 1.0 mL Blood Alcohol Mix<br />
Oven: 40 °C Isothermal<br />
Injector: 200 °C<br />
Carrier: Helium<br />
Sample Equilibration Temperature: 70 °C<br />
Sample Equilibration Time: 15 min.<br />
Vial Pressure: 30 psi<br />
Vial Pressurization Time: 0.15 min.<br />
Vial Sampling Time: 0.01 min.<br />
Transfer Line: 0.32 mm i.d. FS Hydroguard Tubing (N9301357)<br />
Transfer Line Temperature: 200 °C<br />
Injection Port Sleeve: 2 mm i.d.<br />
Split Flow: 20 mL per min.<br />
Part No.<br />
N9316577<br />
Conc. w/v<br />
1. Methanol 0.1%<br />
2. Acetaldehyde 0.2%<br />
3. Ethanol 0.2%<br />
4. Isopropanol 0.1%<br />
5. Acetone 0.01%<br />
6. n-Propanol 0.1%<br />
114
Capillary Column Applications<br />
Forensics/Clinical Toxicology<br />
Cocaine and Metabolites<br />
2 4 6 8 10 12 14 16<br />
TIME (MIN.)<br />
Sympathomimetic Amines – HFBA Derivatives<br />
1. Amphetamine - HFBA<br />
2. Phentermine - HFBA<br />
3. Phenylpropanolamine - HFBA<br />
4. Ephedrine - HFBA<br />
5. Methamphetamine - HFBA<br />
6. Fenfluramine - HFBA<br />
7. Pseudoephedrine - HFBA<br />
8. Methylenedioxyamphetamine - HFBA<br />
9. Methylenedioxymethamphetamine - HFBA<br />
10. Methylphenidate - HFBA<br />
1<br />
2<br />
1<br />
2<br />
3<br />
4<br />
5<br />
6<br />
7<br />
5<br />
4<br />
3<br />
8<br />
1. Ecgonine Methyl Ester (TMS)<br />
2. Ecgonine (TMS)<br />
3. Cocaine<br />
4. Coca Ethylene<br />
5. Benzoylecgonine (TMS)<br />
Column: Elite-5<br />
Dimensions: 30 m, 0.25 mm i.d., 0.25 μm<br />
Sample: 1.0 μL split injection of cocaine<br />
and cocaine metabolites<br />
Oven: 150 °C to 320 °C at 10 °C/min.<br />
Injector: 250 °C<br />
Detector: FID, 300 °C<br />
Carrier: Helium at 30 cm/sec.<br />
Split Ratio: 30:1<br />
Column: Elite-5<br />
Dimensions: 30 m, 0.25 mm i.d., 0.25 μm<br />
Sample: 1.0 μL splitless injection of sympathomimetic amines<br />
Concentration approximately 2.5 ng/μL<br />
Oven: 40 °C (hold 1 min.) to 150 °C at 30 °C/min., to 300 °C at 5 °C/min.<br />
Injector: 225 °C<br />
Detector: MS, 275 °C<br />
Carrier: Helium at 20 cm/sec.<br />
Splitless Hold Time: 1 min.<br />
Part No.<br />
4 6 8 10 12 14 16 18<br />
TIME (MIN.)<br />
9<br />
N9316076<br />
Part No.<br />
10<br />
N9316076<br />
Capillary Column Applications Gas Chromatography<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
115
Capillary Column Applications<br />
Industrial Chemicals<br />
Gas Chromatography Capillary Column Applications<br />
Alcohols and Aldehydes<br />
Column: Elite-WAX ETR<br />
Dimensions: 60 m, 0.53 mm i.d., 1.0 μm<br />
Sample: 1.0 μL split injection of alcohols<br />
and aldehydes<br />
Oven: 45 °C (hold 10 min.) to 250 °C<br />
at 12 °C/min. (hold 20 min.)<br />
Injector: 250 °C<br />
Detector: MS, 285 °C<br />
Carrier: Helium at 50 cm/sec.<br />
Split Ratio: 7:1<br />
Part No.<br />
1<br />
2<br />
Alcohol Mixtures<br />
Column: Elite-WAX ETR<br />
Dimensions: 60 m, 0.53 mm i.d., 1.0 μm<br />
Sample: 1.0 μL split injection of alcohols<br />
Oven: 45 °C (hold 10 min.) to 250 °C<br />
at 12 °C/min. (hold 20 min.)<br />
Injector: 250 °C<br />
Detector: MS (EI), 250 °C<br />
Carrier: Helium at 51 cm/sec.<br />
Split Ratio: 8:1<br />
Part No.<br />
2<br />
3<br />
1<br />
3<br />
1. Pentane<br />
2. Hexane<br />
3. Heptane<br />
4. Ethanol<br />
5. Decane<br />
6. 1-Propanol<br />
N9316571<br />
4<br />
4<br />
N9316571<br />
5<br />
6<br />
7<br />
5 10 15 20 25<br />
TIME (MIN.)<br />
8<br />
7. 1-Butanol<br />
8. Dodecane<br />
9. 1-Pentanol<br />
10. 1-Hexanol<br />
11. Tetradecane<br />
12. 1-Heptanol<br />
9<br />
10<br />
11<br />
12<br />
1. Pentane<br />
2. Heptane<br />
3. Acetaldehyde<br />
4. Dimethoxy Methane<br />
5. Butyraldehyde<br />
6. 3-Pentanol<br />
7. 1-Penten-3-ol<br />
8. 3-Octanol<br />
9. Cyclohexanol<br />
10. Furfural<br />
11. Pentadecane<br />
12. Benzaldehyde<br />
13. Ethylene Glycol and<br />
2-Methyl-2, 4-Pentanediol<br />
14. Furfuryl Alcohol<br />
15. Nonadecane<br />
16. 1, 4-Butanediol<br />
17. Diethylene Glycol<br />
16 18<br />
13<br />
15<br />
17<br />
14<br />
5<br />
5 10 15 20 25<br />
TIME (MIN.)<br />
13. 1-Octanol<br />
14. Hexadecane<br />
15. 1-Nonanol<br />
16. 1-Decanol<br />
17. 1-Undecanol<br />
18. 1-Dodecanol<br />
6<br />
1. Pentane<br />
2. Methanol<br />
3. 2-Methyl-2-Propanol (tert-Butylalcohol)<br />
4. 2-Methyl-3-Buten-2-ol<br />
5. 3-Buten-2-ol<br />
6. Undecane<br />
7. 2, 2-Dimethyl-1-Propanol (Neopentanol)<br />
8. 1-Penten-3-ol<br />
9. 2-Methoxyethanol<br />
10. 2, 2, 2-Trifluoroethanol<br />
1<br />
7<br />
8<br />
9<br />
10<br />
11<br />
2 3 8<br />
9<br />
10<br />
4<br />
12,13<br />
5<br />
6<br />
14<br />
7<br />
11. 2-Ethoxyethanol<br />
12. 1-Pentanol<br />
13. 2-Methyl-1-Pentanol<br />
14. 2, 2-Dimethyl-1-Pentanol<br />
15. Tetradecane<br />
16. trans-2-Hexen-1-ol<br />
17. 1-Octanol<br />
18. Ethylene Glycol<br />
19. 1-Undecanol<br />
20. 1, 4-Butanediol<br />
19<br />
15<br />
16<br />
14<br />
5 10 15 20 25<br />
TIME (MIN.)<br />
11<br />
12<br />
13<br />
15<br />
16<br />
17<br />
17<br />
18<br />
20<br />
116
Capillary Column Applications<br />
Industrial Chemicals<br />
Aldehydes<br />
1<br />
2<br />
Amines and Phenols<br />
1<br />
3<br />
3<br />
2<br />
4<br />
5<br />
6<br />
7<br />
5 10 15 20<br />
TIME (MIN.)<br />
4<br />
5<br />
6<br />
7<br />
8<br />
9<br />
10<br />
11<br />
0 2 4 6 8 10<br />
TIME (MIN.)<br />
12<br />
8<br />
13<br />
9<br />
10<br />
1. Ethanal<br />
2. Propanal<br />
3. Butenal<br />
4. Pentanal<br />
5. Hexanal<br />
6. Heptanal<br />
7. Octanal<br />
8. Nonanal<br />
9. Decanal<br />
10. Undecanal<br />
Column: Elite-WAX<br />
Dimensions: 30 m, 0.25 mm i.d., 0.50 μm<br />
Sample: Split injection of C2-C11 aldehydes mixture,<br />
on-column concentration: 250 ng<br />
Oven: 40 °C (hold 5 min.) to 200 °C at 10 °C/min.<br />
Injector: 200 °C<br />
Detector: 200 °C<br />
Carrier: Hydrogen at 35 cm/sec.<br />
Split Ratio: 100:1<br />
Part No.<br />
N9316404<br />
1. Diethylamine<br />
2. Pyridine<br />
3. Morpholine<br />
4. Phenol<br />
5. Aniline<br />
6. 2-Chlorophenol<br />
7. Diethylenetriamine<br />
8. Octylamine<br />
9. 1-Methyl-2-Pyrrolidinone<br />
10. 2-Nitrophenol<br />
11. 2, 6-Dimethylaniline<br />
12. Nicotine<br />
13. 2-Nitroaniline<br />
Column: Elite-5Amine<br />
Dimensions: 30 m, 0.32 mm i.d., 1.0 μm<br />
Sample: 1.0 μL split injection of miscellaneous<br />
amines and phenols in water<br />
On-Column Conc.: 22 ng<br />
Oven: 120° to 220 °C @ 10 °C/min.<br />
Injector: 305 °C<br />
Linear Velocity: 38 cm/sec. set @ 120 °C<br />
FID Sensitivity: 6.4 x 10-11 AFS<br />
Split Ratio: 25:1<br />
Part No.<br />
N9316677<br />
Capillary Column Applications Gas Chromatography<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
117
Capillary Column Applications<br />
Industrial Chemicals<br />
Gas Chromatography Capillary Column Applications<br />
Aromatics<br />
Column: Elite-WAX ETR<br />
Dimensions: 60 m, 0.53 mm i.d., 1.0 μm<br />
Sample: 1.0 μL split injection of an<br />
aromatics mixture<br />
Oven: 40 °C (hold 10 min.) to 245 °C<br />
at 4 °C/min. (hold 20 min.)<br />
Injector: 250 °C<br />
Detector: MS, 280 °C<br />
Carrier: Helium at 50 cm/sec.<br />
Split Ratio: 7:1<br />
Part No.<br />
N9316571<br />
Industrial Solvents<br />
1. Pentane<br />
2. Hexane<br />
3. Methyl Formate<br />
4. Acetone<br />
5. Tetrahydrofuran<br />
6. 1, 1, 1-Trichloroethane<br />
7. Ethyl Acetate<br />
8. Methanol<br />
9. Methylethyl Ketone<br />
10. Methylene Chloride<br />
11. Chloroform<br />
12. Benzene<br />
13. n-Propyl Alcohol<br />
14. sec-Butyl Alcohol<br />
15. Toluene<br />
16. n-Butyl Acetate<br />
17. Isobutyl Alcohol<br />
18. n-Butyl Alcohol<br />
19. o-Xylene<br />
20. Ethoxyethane<br />
1<br />
1. trans-Decahydronaphthalene<br />
2. 1, 2-Xylene<br />
3. cis-Decahydronaphthalene<br />
4. 1, 3, 5-Trimethylbenzene<br />
5. p-Cymene or p-Isopropyltoluene<br />
6. 1, 2, 4-Trimethylbenzene<br />
7. α-Methyl Benzene<br />
8. 1, 2, 3-Trimethylbenzene 10<br />
7<br />
8<br />
9<br />
2<br />
3<br />
4<br />
5<br />
6<br />
11<br />
TIME (MIN.)<br />
9. Diisopropylbenzene<br />
10. Triethylbenzene<br />
11. Pentadecane<br />
12. Nitrobenzene<br />
13. Nonadecane<br />
14. o-Cresol<br />
15. Bibenzyl<br />
15 20 30 35 40 45 50 55<br />
2<br />
1<br />
8,9<br />
3<br />
5<br />
4<br />
6,7 10,11 15<br />
Column: Elite-MWAX<br />
Dimensions: 30 m, 0.53 mm i.d., 1.0 μm<br />
Sample: Wet needle injection of neat solvents<br />
Oven: 50 °C to 220 °C at 10 °C/min.<br />
Injector: 250 °C<br />
Detector: FID, 250 °C<br />
Carrier: Helium at 20 cm/sec.<br />
13<br />
12<br />
14<br />
16<br />
17 18<br />
19<br />
20<br />
2 4 6 8 10<br />
TIME (MIN.)<br />
Industrial Solvents<br />
1. Pentane<br />
2. Hexane<br />
3. Methyl Formate<br />
4. Acetone<br />
5. Tetrahydrofuran<br />
6. 1, 1, 1-Trichloroethane<br />
7. Ethyl Acetate<br />
8. Methanol<br />
9. Methylethyl Ketone<br />
10. Methylene Chloride<br />
11. Chloroform<br />
12. Benzene<br />
13. n-Propyl Alcohol<br />
14. sec-Butyl Alcohol<br />
15. Toluene<br />
16. n-Butyl Acetate<br />
17. Isobutyl Alcohol<br />
18. n-Butyl Alcohol<br />
19. o-Xylene<br />
20. Ethoxyethane<br />
12<br />
1<br />
2<br />
3<br />
13<br />
6,7<br />
Column: Elite-WAX ETR<br />
Dimensions: 30 m, 0.53 mm i.d., 1.0 μm<br />
Sample: Wet needle injection of neat solvents<br />
Oven: 50 °C to 220 °C at 10 °C/min.<br />
Injector: 250 °C<br />
Detector: 250 °C<br />
Carrier: Helium at 20 cm/sec.<br />
14<br />
15<br />
10,11 15 19<br />
8,9<br />
16<br />
5<br />
14<br />
13 17<br />
4<br />
18<br />
12<br />
2 4 6 8 10<br />
TIME (MIN.)<br />
Part No. N9316478 Part No. N9316569<br />
20<br />
118
Capillary Column Applications<br />
Petroleum<br />
Prudhoe Bay Crude Oil<br />
1. Benzene<br />
2. Heptane<br />
3. Toluene<br />
4. Octane<br />
5. m-Xylene and p-Xylene<br />
6. o-Xylene<br />
7. Nonane<br />
8. Decane<br />
9. Undecane<br />
10. Dodecane<br />
1<br />
2<br />
3<br />
4<br />
Volatile Hydrocarbons<br />
5<br />
6<br />
7<br />
8<br />
9<br />
11. Tridecane<br />
12. Tetradecane<br />
13. Pentadecane<br />
14. Hexadecane<br />
15. Heptadecane<br />
16. Pristane<br />
17. Octadecane<br />
18. Phytane<br />
19. Nonadecane<br />
20. Eicosane<br />
10<br />
11<br />
12<br />
13<br />
14<br />
15<br />
16<br />
21. Heneicosane<br />
22. Docosane<br />
23. Tricosane<br />
24. Tetracosane<br />
25. Pentacosane<br />
26. Hexacosane<br />
27. Heptacosane<br />
28. Octacosane<br />
17<br />
18<br />
19<br />
20<br />
21<br />
22<br />
23<br />
Column: Elite-1<br />
Dimensions: 30 m, 0.53 mm i.d., 3.0 μm<br />
Sample: 0.4 μL split injection of Prudhoe Bay crude oil<br />
Oven: 40 °C to 285 °C at 5 °C/min. (hold 30 min.)<br />
Injector: 285 °C<br />
Detector: 285 °C<br />
Carrier: Hydrogen at 40 cm/sec.<br />
Split Ratio: 50:1<br />
4 8 12 16 20 24 28 32 36 40 44 48 52 56 60 64 68 72 76 80<br />
TIME (MIN.)<br />
1<br />
2,3<br />
4<br />
5 7<br />
6<br />
8,9<br />
13 11<br />
15<br />
12<br />
1 2 3 4 5 6 7 8 9 10 11 12 13 14<br />
TIME (MIN.)<br />
10<br />
14<br />
16<br />
17<br />
24<br />
Part No.<br />
25<br />
26<br />
N9316051<br />
27<br />
1. Methane<br />
2. Ethylene<br />
3. Acetylene<br />
4. Ethane<br />
5. Propylene<br />
6. Propane<br />
7. Cyclopropane<br />
8. Propadiene<br />
9. Propyne<br />
28<br />
10. Isobutane<br />
11. 1, 3-Butadiene<br />
12. 1-Butene<br />
13. n-Butane<br />
14. cis-2-Butene<br />
15. trans-2-Butene<br />
16. Isopentane<br />
17. n-Pentane<br />
Column: Elite-Q PLOT<br />
Dimensions: 30 m, 0.32 mm i.d.<br />
Sample: 300 μL split injection (40:1), 1000 ppm<br />
Oven: 50 °C (2 min.) to 220 °C at 15 °C/min.<br />
Injector: 250 °C<br />
Detector: FID, 250 °C<br />
Carrier: Helium at 42 cm/sec.<br />
Split Flow: 40 mL/min.<br />
Part No.<br />
N9316359<br />
Capillary Column Applications Gas Chromatography<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
119
Capillary Columns<br />
Phase Cross-Reference<br />
Gas Chromatography Capillary Columns<br />
Phase Phase Description Equivalent Phase<br />
Elite-1, Elite-1ht 100% Dimethyl Packed: OV-1, OV-101, SP-2100, DC-200, UC-W982, S 96, CP-Sil 5, SE-30<br />
Capillary: DB-1, DB-1ht, HP-1, HP-101, Ultra-1, SPB-1, CP-Sil 5CB, Cl-Sil5CBMS,<br />
RSL-150, RSL-160, Rtx-1, BP-1, CB-1, OV-1, 007-1(MS), SP-2100, SE-30<br />
Elite-5, Elite-5ht, 5% Diphenyl – 95% Dimethyl Packed: OV-3, OV-73, Dexsil 300, Fluorolube, CP-Sil 8<br />
Elite-5ms<br />
Capillary: DB-5, DB-5ms, DB-5ht, HP-5, Ultra-2, SPB-5, CP-Sil 8CB, RSL-200, Rtx-5,<br />
BP-5, CB-5, OV-5, 007-2(MPS-5), SE-52, SE-54, XTI-5, Rtx-5 ms, PTE-5, HP-5MS<br />
Elite-5Amine 5% Diphenyl – 95% Dimethyl Polysiloxane Rtx-5Amine; PTA-5<br />
Elite-17, Elite-17ht, 50% Phenyl – 50% Methyl Packed: OV-17, OV-11, OV-22, SP-2250, DC-710<br />
Elite-17ms<br />
Capillary: DB-17, DB-17ht, HP-17, RSL-300, Rtx-50, 007-17(MPS-50),<br />
SP-2250, HP-50+<br />
Elite-35, Elite-35ms 35% Phenyl – 65% Methyl Capillary: DB-35, DB-35ms, Rtx-35, SPB-35, AT-35, Sup-Herb<br />
Elite-200 Trifluoropropylmethyl Polysiloxane DB-210; AT-210; VF-200MS; 007-210; Rtx-200<br />
Elite-225 50% Cyanopropylmethyl – Packed: OV-225, Silar 5 CP<br />
50% Phenylmethyl Capillary: DB-225, HP-225, SP-2330, CP-Sil 43CB, RSL-500, Rtx-225,<br />
BP-225, CB-225, OV-225, 007-225<br />
Elite-608<br />
Specialty phase for semivolatile<br />
pesticides (U.S. EPA 608)<br />
Capillary: SPB-608, NON-PAKD Pesticide, DB-608, 007-608, HP-608<br />
Elite-624, Specialty phase for volatiles Capillary: DB-624, DB-VRX, VOCOL, NONPAKD AT-624, Rtx-Volatiles,<br />
Elite-Volatiles (U.S. EPA 624 and 502.2) Rtx-502.2, 007-624, 007-502, HP-624, CP-624, Rtx-624<br />
Elite-1301 6% Cyanopropylphenyl – 94% Methyl Capillary: DB-1301, Rtx-1301, CP-624<br />
Elite-1701 14% Cyanopropylphenyl – 86% Dimethyl Packed: OV-1701<br />
Capillary: DB-1701, SPB-7, CP-Sil 19CB, Rtx-1701, BP-10, CB-1701,<br />
OV-1701, 007-1701<br />
Elite-Alumina PLOT phase for analysis Packed: Alumina<br />
of light hydrocarbons<br />
Capillary: GS-Alumina, Al 2 O 3 /KC1, Al 2 O 3 /Na 2 SO 4 , RT-Alumina<br />
Elite-Betacydex Betacyclodextrin for chiral separations Capillary: Cyclodex-B, LIPODEX C, Chirasil-D/L-Val, Rt-bDEXm<br />
Elite-CLPesticides Specialty phase for chlorinated pesticides Rtx-CLPesticides<br />
Elite-CLPesticides2 Specialty phase for chlorinated pesticides Rtx-CLPesticides<br />
Elite-FFAP Polyethylene Glycol – Acid Modified Packed: OV-351, FFAP, Carbowax 20M-Terephthalic acid<br />
Capillary: DB-WAX, HP-FFAP, Nukol, SUPEROX FA, STABILWAX-DA, 007-FFAP,<br />
OV-351, DB-FFAP<br />
Elite-Molesieve PLOT phase for analysis Packed: Molesieve 5A<br />
of permanent gases<br />
Capillary: GS-Molesieve, Molesieve 5A, #PLT-5A, Rt-Molesieve 5A<br />
Elite-PONA<br />
Dimethylpolysiloxane processed for<br />
detailed analysis of petroleum naphtha Capillary: DB-Petro100, Petrocol DH, HP-PONA, SPB-1, 007-1, Rtx-1 PONA<br />
Elite-Q PLOT phase for analysis Packed: Chomosorb 101, HayeSep Q, Porapak Q<br />
of light gases and hydrocarbons<br />
Capillary: GS-Q, PoraPLOT Q, Rt-QPLOT<br />
Elite-VMS Specialty phase for U.S. EPA Volatile Organics Rtx-VMS<br />
Elite-WAX Polyethylene Glycol Packed: Carbowax 20M, SUPEROX, SUPELCOWAX 10, PEG<br />
Capillary: DB-FFAP, HP-20M, SUPELCOWAX 10, CP-WAX 52CB, SUPEROX II,<br />
CB-WAX, STABILWAX, BP-20, Elite-CW, 007-CW, Carbowax, HP-Innowax<br />
120
Capillary Columns<br />
PerkinElmer Elite Series Capillary Columns<br />
Elite-1 Dimethylpolysiloxane<br />
100% Dimethyl Polysiloxane phase:<br />
The 100% Dimethyl Polysiloxane is a highly versatile phase<br />
that is extremely rugged, exhibiting long column lifetime,<br />
low bleed, and high maximum operating temperatures.<br />
Primary applications:<br />
Elite columns are ideal for the analysis of non-polar<br />
petrochemical samples, such as detailed hydrocarbon<br />
analysis, hydrocarbon gases, petroleum oxygenates,<br />
petroleum aromatics, fuels, waxes, oils, sulfur compounds,<br />
mercaptans, and carbon disulfide. It also is an excellent<br />
phase for solvents, chemicals, flavors, fragrances, essential<br />
oils, air toxins, chlorofluorocarbons, arson analysis, and<br />
high-temperature applications.<br />
Inner Film Temperature<br />
Diameter Length Thickness Limits<br />
(mm i.d.) (m) (μm) (°C) Part No. Each (€)<br />
0.05 10 0.05 -60 to 330/350 N9316056 650<br />
0.05 10 0.20 -60 to 330/350 N9316057 650<br />
0.10 10 0.10 -60 to 330/350 N9316058 574<br />
0.10 20 0.40 -60 to 320/340 N9316061 625<br />
0.18 10 0.18 -60 to 330/350 N9316001 332<br />
0.18 10 0.40 -60 to 320/340 N9316002 332<br />
0.18 20 0.18 -60 to 330/350 N9316003 523<br />
0.18 20 0.40 -60 to 320/340 N9316004 445<br />
0.18 40 0.40 -60 to 320/340 N9316005 944<br />
0.20 12 0.33 -60 to 330/350 N9316062 325<br />
0.20 25 0.33 -60 to 330/350 N9316063 445<br />
0.20 50 0.33 -60 to 330/350 N9316064 738<br />
0.25 15 0.10 -60 to 330/350 N9316006 357<br />
0.25 15 0.25 -60 to 330/350 N9316007 318<br />
0.25 15 1.00 -60 to 320/340 N9316008 318<br />
0.25 30 0.10 -60 to 330/350 N9316009 606<br />
0.25 30 0.25 -60 to 330/350 N9316010 547<br />
0.25 30 1.00 -60 to 330/350 N9316011 547<br />
0.25 60 0.10 -60 to 330/350 N9316012 1046<br />
0.25 60 0.25 -60 to 330/350 N9316013 930<br />
0.25 60 1.00 -60 to 320/340 N9316014 891<br />
0.25 100 0.50 -60 to 300/320 N9316015 1057<br />
0.32 15 0.10 -60 to 330/350 N9316016 381<br />
0.32 15 0.25 -60 to 330/350 N9316017 356<br />
0.32 15 1.00 -60 to 320/340 N9316018 389<br />
0.32 15 3.00 -60 to 280/300 N9316019 389<br />
0.32 15 5.00 -60 to 260/280 N9316020 356<br />
0.32 25 0.52 -60 to 330/350 N9316021 483<br />
0.32 30 0.10 -60 to 330/350 N9316022 573<br />
0.32 30 0.25 -60 to 330/350 N9316023 547<br />
0.32 30 1.00 -60 to 320/340 N9316024 573<br />
0.32 30 3.00 -60 to 280/300 N9316025 573<br />
0.32 30 5.00 -60 to 260/280 N9316026 445<br />
0.32 60 0.10 -60 to 330/350 N9316027 1141<br />
0.32 60 0.25 -60 to 330/350 N9316028 1122<br />
0.32 60 1.00 -60 to 320/340 N9316029 993<br />
0.32 60 3.00 -60 to 280/300 N9316030 1122<br />
0.32 60 5.00 -60 to 260/280 N9316031 993<br />
0.45* 5 4.25 -60 to 260/280 N9316032 147<br />
0.45* 15 0.13 -60 to 340/360 N9316033 402<br />
0.45* 15 0.42 -60 to 310/330 N9316037 402<br />
0.45* 15 1.27 -60 to 310/330 N9316034 402<br />
0.45* 15 2.55 -60 to 270/290 N9316035 402<br />
0.45* 15 4.25 -60 to 260/280 N9316036 402<br />
0.45* 30 0.42 -60 to 310/330 N9316041 721<br />
0.45* 30 1.27 -60 to 310/330 N9316038 721<br />
0.45* 30 2.55 -60 to 270/290 N9316039 721<br />
Inner Film Temperature<br />
Diameter Length Thickness Limits<br />
(mm i.d.) (m) (μm) (°C) Part No. Each (€)<br />
0.45* 30 4.25 -60 to 260/280 N9316040 721<br />
0.45* 60 1.27 -60 to 310/330 N9316042 1148<br />
0.45* 105 2.55 -60 to 270/290 N9316043 1836<br />
0.53 5 5.00 -60 to 270/290 N9316044 147<br />
0.53 15 0.15 -60 to 320/340 N9316045 356<br />
0.53 15 0.50 -60 to 310/330 N9316049 356<br />
0.53 15 1.50 -60 to 310/330 N9316046 356<br />
0.53 15 3.00 -60 to 270/290 N9316047 292<br />
0.53 15 5.00 -60 to 270/290 N9316048 402<br />
0.53 30 0.50 -60 to 310/320 N9316053 636<br />
0.53 30 1.50 -60 to 310/320 N9316050 636<br />
0.53 30 3.00 -60 to 270/290 N9316051 636<br />
0.53 30 5.00 -60 to 270/290 N9316052 636<br />
0.53 60 1.50 -60 to 310/330 N9316054 993<br />
* Ferrule size same as 0.53.<br />
Elite-1ht (High-Temp)<br />
Dimethylpolysiloxane<br />
Inner Film Temperature<br />
Diameter Length Thickness Limits<br />
(mm i.d.) (m) (μm) (°C) Part No. Each (€)<br />
0.25 15 0.10 -60 to 380 N9316268 383<br />
0.25 30 0.10 -60 to 380 N9316269 573<br />
0.32 15 0.10 -60 to 380 N9316270 414<br />
0.32 30 0.10 -60 to 380 N9316271 636<br />
Capillary Columns Gas Chromatography<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
121
Capillary Columns<br />
PerkinElmer Elite Series Capillary Columns<br />
Gas Chromatography Capillary Columns<br />
Elite-5 (5% – Diphenyl) –<br />
Dimethylpolysiloxane<br />
Inner Film Temperature<br />
Diameter Length Thickness Limits<br />
(mm i.d.) (m) (μm) (°C) Part No. Each (€)<br />
0.05 10 0.05 -60 to 325/350 N9316104 650<br />
0.05 10 0.20 -60 to 325/350 N9316105 650<br />
0.10 20 0.10 -60 to 330/350 N9316108 547<br />
0.10 20 0.40 -60 to 320/340 N9316109 625<br />
0.18 20 0.18 -60 to 325/340 N9316068 523<br />
0.18 10 0.18 -60 to 325/340 N9316066 332<br />
0.18 10 0.40 -60 to 315/330 N9316067 292<br />
0.18 20 0.40 -60 to 315/330 N9316069 445<br />
0.18 40 0.40 -60 to 315/330 N9316071 829<br />
0.20 12 0.33 -60 to 320/350 N9316110 325<br />
0.20 25 0.33 -60 to 330/350 N9316111 445<br />
0.20 50 0.33 -60 to 330/350 N9316112 848<br />
0.25 15 0.10 -60 to 330/350 N9316072 357<br />
0.25 15 0.25 -60 to 330/350 N9316073 318<br />
0.25 15 1.00 -60 to 320/340 N9316074 292<br />
0.25 30 0.10 -60 to 330/350 N9316075 573<br />
0.25 30 0.25 -60 to 330/350 N9316076 509<br />
0.25 30 1.00 -60 to 320/340 N9316077 509<br />
0.25 60 0.10 -60 to 330/350 N9316078 1046<br />
0.25 60 0.25 -60 to 330/340 N9316079 891<br />
0.25 60 1.00 -60 to 320/350 N9316080 891<br />
0.32 15 0.10 -60 to 330/350 N9316081 389<br />
0.32 15 0.25 -60 to 330/350 N9316082 356<br />
0.32 15 1.00 -60 to 330/350 N9316083 389<br />
0.32 25 0.52 -60 to 330/350 N9316084 509<br />
0.32 30 0.10 -60 to 330/350 N9316085 547<br />
0.32 30 0.25 -60 to 330/350 N9316086 573<br />
0.32 30 1.00 -60 to 330/350 N9316087 547<br />
0.32 50 1.00 -60 to 330/350 N9316088 828<br />
0.32 60 0.10 -60 to 330/350 N9316089 1141<br />
0.32 60 0.25 -60 to 330/350 N9316090 993<br />
0.32 60 1.00 -60 to 330/350 N9316091 993<br />
0.45* 15 0.42 -60 to 310/330 N9316093 402<br />
0.45* 15 1.27 -60 to 310/330 N9316092 402<br />
0.45* 30 0.42 -60 to 310/330 N9316096 721<br />
0.45* 30 1.27 -60 to 310/330 N9316094 721<br />
0.45* 30 4.25 -60 to 270/290 N9316095 721<br />
0.45* 60 1.27 -60 to 310/330 N9316097 1148<br />
0.53 15 0.50 -60 to 310/330 N9316099 363<br />
0.53 15 1.50 -60 to 310/330 N9316098 356<br />
0.53 30 0.50 -60 to 310/330 N9316102 636<br />
0.53 30 1.50 -60 to 310/330 N9316100 611<br />
0.53 30 5.00 -60 to 270/290 N9316101 636<br />
0.53 60 1.50 -60 to 310/330 N9316103 993<br />
* Ferrule size same as 0.53.<br />
Elite-5Amine<br />
Inner Film Temperature<br />
Diameter Length Thickness Limits<br />
(mm i.d.) (m) (μm) (°C) Part No. Each (€)<br />
0.25 30 0.50 -60 to 300/315 N9316673 675<br />
0.25 15 1.00 -60 to 300/315 N9316674 445<br />
0.25 30 1.00 -60 to 300/315 N9316675 675<br />
0.32 15 1.00 -60 to 300/315 N9316676 458<br />
0.32 30 1.00 -60 to 300/315 N9316677 713<br />
0.32 15 1.50 -60 to 290/305 N9316678 458<br />
0.32 30 1.50 -60 to 290/305 N9316679 713<br />
0.53 30 1.00 -60 to 290/305 N9316680 789<br />
0.53 15 3.00 -60 to 280/305 N9316681 483<br />
0.53 30 3.00 -60 to 280/305 N9316682 789<br />
0.25 15 0.50 -60 to 300/315 N9316684 445<br />
Elite-5ht (High-Temp)<br />
(5% – Diphenyl) –<br />
Dimethylpolysiloxane<br />
Inner Film Temperature<br />
Diameter Length Thickness Limits<br />
(mm i.d.) (m) (μm) (°C) Part No. Each (€)<br />
0.25 15 0.10 -60 to 400 N9316272 383<br />
0.25 30 0.10 -60 to 400 N9316273 611<br />
0.32 15 0.10 -60 to 400 N9316274 356<br />
0.32 30 0.10 -60 to 400 N9316275 611<br />
Elite-5ms (5% – Diphenyl) –<br />
Dimethylpolysiloxane<br />
Inner Film Temperature<br />
Diameter Length Thickness Limits<br />
(mm i.d.) (m) (μm) (°C) Part No. Each (€)<br />
0.18 20 0.18 -60 to 325/340 N9316276 547<br />
0.18 40 0.18 -60 to 325/340 N9316277 930<br />
0.20 12 0.33 -60 to 330/350 N9316301 344<br />
0.20 25 0.33 -60 to 330/350 N9316302 483<br />
0.20 50 0.33 -60 to 330/350 N9316303 828<br />
0.25 15 0.10 -60 to 330/350 N9316278 402<br />
0.25 15 0.25 -60 to 330/350 N9316279 402<br />
0.25 15 1.00 -60 to 325/350 N9316280 402<br />
0.25 30 0.10 -60 to 330/350 N9316281 638<br />
0.25 30 0.25 -60 to 330/350 N9316282 611<br />
0.25 30 1.00 -60 to 325/350 N9316283 611<br />
0.25 30 0.50 -60 to 330/350 N9316284 611<br />
0.25 60 0.10 -60 to 330/350 N9316285 1084<br />
0.25 60 0.25 -60 to 330/350 N9316286 1019<br />
0.25 60 1.00 -60 to 325/350 N9316287 993<br />
0.32 15 0.10 -60 to 330/350 N9316288 421<br />
0.32 15 0.25 -60 to 330/350 N9316289 421<br />
0.32 15 1.00 -60 to 325/350 N9316290 421<br />
0.32 25 0.52 -60 to 330/350 N9316291 561<br />
0.32 30 0.10 -60 to 330/350 N9316292 695<br />
0.32 30 0.25 -60 to 330/350 N9316293 636<br />
0.32 30 1.00 -60 to 325/350 N9316294 636<br />
0.32 30 0.50 -60 to 330/350 N9316295 636<br />
0.32 60 0.10 -60 to 330/350 N9316296 1186<br />
0.32 60 0.25 -60 to 330/350 N9316297 1083<br />
0.32 60 1.00 -60 to 330/350 N9316298 1186<br />
0.53 15 1.50 -60 to 310/330 N9316299 434<br />
0.53 30 1.50 -60 to 310/330 N9316300 700<br />
122
Capillary Columns<br />
PerkinElmer Elite Series Capillary Columns<br />
Elite-17 (50% – Phenyl) –<br />
Methylpolysiloxane<br />
Inner Film Temperature<br />
Diameter Length Thickness Limits<br />
(mm i.d.) (m) (μm) (°C) Part No. Each (€)<br />
0.05 10 0.05 40 to 280/300 N9316138 650<br />
0.05 10 0.10 40 to 280/300 N9316139 650<br />
0.10 10 0.10 40 to 280/300 N9316140 574<br />
0.10 10 0.02 40 to 280/300 N9316141 574<br />
0.10 20 0.10 40 to 280/300 N9316142 625<br />
0.10 20 0.20 40 to 280/300 N9316143 625<br />
0.18 10 0.18 40 to 310/300 N9316113 332<br />
0.18 10 0.30 40 to 300/320 N9316114 332<br />
0.18 20 0.18 40 to 310/330 N9316115 523<br />
0.18 20 0.30 40 to 300/320 N9316116 523<br />
0.25 15 0.15 40 to 300/320 N9316117 357<br />
0.25 15 0.25 40 to 300/320 N9316118 357<br />
0.25 15 0.50 40 to 290/310 N9316119 357<br />
0.25 30 0.15 40 to 300/320 N9316120 606<br />
0.25 30 0.25 40 to 300/320 N9316121 547<br />
0.25 30 0.50 40 to 290/310 N9316122 547<br />
0.25 60 0.25 40 to 290/310 N9316123 891<br />
0.32 15 0.15 40 to 300/320 N9316124 389<br />
0.32 15 0.25 40 to 300/320 N9316125 389<br />
0.32 15 0.50 40 to 290/310 N9316126 389<br />
0.32 30 0.15 40 to 300/320 N9316127 644<br />
0.32 30 0.25 40 to 300/320 N9316128 644<br />
0.32 30 0.50 40 to 290/310 N9316129 547<br />
0.45* 5 1.70 40 to 260/280 N9316130 147<br />
0.45* 15 0.85 40 to 270/290 N9316131 402<br />
0.45* 30 0.85 40 to 270/290 N9316132 721<br />
0.45* 60 0.85 40 to 260/280 N9316133 1148<br />
0.53 5 2.00 40 to 250/270 N9316134 147<br />
0.53 15 1.00 40 to 260/280 N9316135 356<br />
0.53 30 1.00 40 to 260/280 N9316136 636<br />
0.53 60 1.00 40 to 260/280 N9316137 1148<br />
* Ferrule size same as 0.53<br />
Elite-17ht (High-Temp)<br />
(50% – Phenyl) –<br />
Methylpolysiloxane<br />
Inner Film Temperature<br />
Diameter Length Thickness Limits<br />
(mm i.d.) (m) (μm) (°C) Part No. Each<br />
0.25 15 0.15 40 to 300/320 N9316263 383<br />
0.25 30 0.15 40 to 300/320 N9316264 625<br />
0.32 15 0.15 40 to 300/320 N9316265 414<br />
0.32 30 0.15 40 to 300/320 N9316266 676<br />
0.32 60 0.15 40 to 300/320 N9316267 1173<br />
(€)<br />
Elite-17ms (Low Bleed)<br />
(50% – Phenyl) –<br />
Methylpolysiloxane<br />
Inner Film Temperature<br />
Diameter Length Thickness Limits<br />
(mm i.d.) (m) (μm) (°C) Part No. Each (€)<br />
0.18 20 0.18 40 to 320/340 N9316534 599<br />
0.25 15 0.15 40 to 300/320 N9316535 434<br />
0.25 15 0.25 40 to 300/320 N9316536 434<br />
0.25 30 0.15 40 to 300/320 N9316537 611<br />
0.25 30 0.25 40 to 300/320 N9316538 701<br />
0.25 60 0.25 40 to 300/320 N9316539 1205<br />
0.32 15 0.15 40 to 300/320 N9316540 471<br />
0.32 15 0.25 40 to 300/320 N9316541 472<br />
0.32 30 0.15 40 to 300/320 N9316542 759<br />
Elite-35 (35% – Diphenyl) –<br />
Dimethylpolysiloxane<br />
Inner Film Temperature<br />
Diameter Length Thickness Limits<br />
(mm i.d.) (m) (μm) (°C) Part No. Each (€)<br />
0.25 30 0.15 40 to 300/320 N9316144 606<br />
0.25 30 0.25 40 to 300/320 N9316145 606<br />
0.32 30 0.25 40 to 300/320 N9316146 547<br />
0.32 30 0.50 40 to 290/310 N9316147 644<br />
0.45* 15 0.85 40 to 280/300 N9316148 402<br />
0.45* 30 0.42 40 to 290/310 N9316150 721<br />
0.45* 30 0.85 40 to 280/300 N9316149 721<br />
0.53 15 1.00 40 to 260/280 N9316151 402<br />
0.53 30 0.50 40 to 260/280 N9316153 611<br />
0.53 30 1.00 40 to 260/280 N9316152 721<br />
Elite-35ms (35% – Phenyl) –<br />
Methylpolysiloxane<br />
Inner Film Temperature<br />
Diameter Length Thickness Limits<br />
(mm i.d.) (m) (μm) (°C) Part No. Each (€)<br />
0.20 25 0.33 50 to 320/340 N9316446 536<br />
0.25 15 0.25 50 to 320/340 N9316436 402<br />
0.25 30 0.15 50 to 320/340 N9316437 644<br />
0.25 30 0.25 50 to 320/340 N9316438 644<br />
0.25 60 0.25 50 to 320/340 N9316439 1019<br />
0.32 15 0.25 50 to 320/340 N9316440 421<br />
0.32 30 0.25 50 to 320/340 N9316441 636<br />
0.32 60 0.25 50 to 320/340 N9316442 1186<br />
0.53 15 1.00 50 to 290/310 N9316443 434<br />
0.53 30 1.00 50 to 290/310 N9316444 759<br />
0.53 30 0.50 50 to 300/320 N9316445 759<br />
Capillary Columns Gas Chromatography<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
123
Capillary Columns<br />
PerkinElmer Elite Series Capillary Columns<br />
Gas Chromatography Capillary Columns<br />
Elite-200 Trifluoropropylmethyl<br />
Polysiloxane<br />
Inner Film Temperature<br />
Diameter Length Thickness Limits<br />
(mm i.d.) (m) (μm) (°C) Part No. Each (€)<br />
0.18 10 0.20 -20 to 310/330 N9316610 343<br />
0.18 20 0.20 -20 to 310/330 N9316611 522<br />
0.18 40 0.20 -20 to 310/330 N9316612 917<br />
0.18 10 0.40 -20 to 310/330 N9316613 343<br />
0.18 20 0.40 -20 to 310/330 N9316614 522<br />
0.18 40 0.40 -20 to 310/330 N9316615 917<br />
0.25 15 0.10 -20 to 320/340 N9316616 381<br />
0.25 30 0.10 -20 to 320/340 N9316617 611<br />
0.25 15 0.25 -20 to 320/340 N9316618 369<br />
0.25 30 0.25 -20 to 320/340 N9316619 598<br />
0.25 15 0.50 -20 to 310/330 N9316620 369<br />
0.25 30 0.50 -20 to 310/330 N9316621 598<br />
0.25 15 1.00 -20 to 290/310 N9316622 369<br />
0.25 30 1.00 -20 to 290/310 N9316623 598<br />
0.25 60 1.00 -20 to 290/310 N9316624 993<br />
0.32 15 0.25 -20 to 320/340 N9316625 420<br />
0.32 30 0.25 -20 to 320/340 N9316626 636<br />
0.32 15 0.50 -20 to 310/330 N9316627 420<br />
0.32 30 0.50 -20 to 310/330 N9316628 636<br />
0.32 15 1.00 -20 to 290/310 N9316629 420<br />
0.32 30 1.00 -20 to 290/310 N9316630 636<br />
0.32 60 1.00 -20 to 290/310 N9316631 1095<br />
0.32 15 1.50 -20 to 280/300 N9316632 420<br />
0.32 30 1.50 -20 to 280/300 N9316633 636<br />
0.32 60 1.50 -20 to 280/300 N9316634 1095<br />
0.53 15 0.25 -20 to 310/330 N9316635 445<br />
0.53 30 0.25 -20 to 310/330 N9316636 726<br />
0.53 60 0.25 -20 to 310/330 N9316637 1185<br />
0.53 15 0.50 -20 to 300/320 N9316638 445<br />
0.53 30 0.50 -20 to 300/320 N9316639 726<br />
0.53 60 0.50 -20 to 300/320 N9316640 1185<br />
0.53 15 1.00 -20 to 290/310 N9316641 445<br />
0.53 30 1.00 -20 to 290/310 N9316642 726<br />
0.53 60 1.00 -20 to 290/310 N9316643 1185<br />
0.53 15 1.50 -20 to 280/300 N9316644 445<br />
0.53 30 1.50 -20 to 280/300 N9316645 726<br />
0.53 60 1.50 -20 to 280/300 N9316646 1185<br />
0.53 15 3.00 -20 to 260/280 N9316647 445<br />
0.53 30 3.00 -20 to 260/280 N9316648 726<br />
0.53 60 3.00 -20 to 260/280 N9316649 1185<br />
Elite-225 (50% –<br />
Cyanopropylmethyl) –<br />
Phenylmethylpolysiloxane<br />
Inner Film Temperature<br />
Diameter Length Thickness Limits<br />
(mm i.d.) (m) (μm) (°C) Part No. Each<br />
0.05 10 0.05 45 to 220/240 N9316186 636<br />
0.10 20 0.10 45 to 220/240 N9316187 625<br />
0.18 10 0.20 45 to 220/240 N9316172 332<br />
0.18 20 0.20 45 to 220/240 N9316173 523<br />
0.25 15 0.15 45 to 220/240 N9316174 363<br />
0.25 15 0.25 45 to 220/240 N9316175 318<br />
0.25 30 0.15 45 to 220/240 N9316176 619<br />
0.25 30 0.25 45 to 220/240 N9316177 547<br />
0.32 15 0.15 45 to 220/240 N9316178 402<br />
0.32 15 0.25 45 to 220/240 N9316179 402<br />
0.32 30 0.15 45 to 220/240 N9316180 670<br />
0.32 30 0.25 45 to 220/240 N9316181 573<br />
0.45* 15 0.85 40 to 200/220 N9316182 395<br />
0.45* 30 0.85 40 to 200/220 N9316183 740<br />
0.53 15 1.00 40 to 200/220 N9316184 395<br />
0.53 30 1.00 40 to 200/220 N9316185 636<br />
Elite-502.2 Specialty Phase for<br />
Analysis of Volatiles (U.S. EPA 502.2)<br />
Inner Film Temperature<br />
Diameter Length Thickness Limits<br />
(mm i.d.) (m) (μm) (°C) Part No. Each<br />
0.25 60 1.40 0 to 250/270 N9316498 1065<br />
0.45* 105 2.55 0 to 250/270 N9316189 1836<br />
0.45* 75 2.55 0 to 250/270 N9316188 1338<br />
0.53 105 3.00 0 to 250/270 N9316190 1210<br />
Elite-608 Specialty Phase for<br />
Semivolatile Pesticides (U.S. EPA 608)<br />
Inner Film Temperature<br />
Diameter Length Thickness Limits<br />
(mm i.d.) (m) (μm) (°C) Part No. Each (€)<br />
0.32 30 0.50 40 to 290/310 N9316191 547<br />
0.45* 15 0.42 40 to 270/290 N9316194 402<br />
0.45* 15 0.70 40 to 260/280 N9316192 402<br />
0.45* 30 0.42 40 to 270/290 N9316195 721<br />
0.45* 30 0.70 40 to 260/280 N9316193 721<br />
0.53 15 0.50 40 to 270/290 N9316198 402<br />
0.53 15 0.83 40 to 260/280 N9316196 402<br />
0.53 30 0.50 40 to 270/290 N9316199 611<br />
0.53 30 0.83 40 to 260/280 N9316197 700<br />
* Ferrule size same as 0.53<br />
(€)<br />
(€)<br />
124
Capillary Columns<br />
PerkinElmer Elite Series Capillary Columns<br />
Elite-624 Specialty Phase for<br />
Analysis of Volatiles (U.S. EPA 624)<br />
Inner Film Temperature<br />
Diameter Length Thickness Limits<br />
(mm i.d.) (m) (μm) (°C) Part No. Each (€)<br />
Inner Film Temperature<br />
Diameter Length Thickness Limits<br />
(mm i.d.) (m) (μm) (°C) Part No. Each (€)<br />
0.18 20 1.00 -20 to 240 N9316200 510<br />
0.20 25 1.12 -20 to 240 N9316209 445<br />
0.25 30 1.40 -20 to 240 N9316201 573<br />
0.25 60 1.40 -20 to 240 N9316202 1065<br />
0.32 30 1.80 -20 to 240 N9316203 611<br />
0.32 60 1.80 -20 to 240 N9316204 1057<br />
0.45* 30 2.55 -20 to 240 N9316205 829<br />
0.45* 75 2.55 -20 to 240 N9316206 1249<br />
0.53 30 3.00 -20 to 240 N9316207 700<br />
0.53 75 3.00 -20 to 240 N9316208 1249<br />
* Ferrule size same as 0.53<br />
Elite-1301<br />
(6% – Cyanopropylphenyl) –<br />
Methylpolysiloxane<br />
Inner Film Temperature<br />
Diameter Length Thickness Limits<br />
(mm i.d.) (m) (μm) (°C) Part No. Each<br />
0.18 10 0.40 -20 to 280 N9316210 332<br />
0.18 20 0.40 -20 to 280 N9316211 523<br />
0.25 15 0.25 -20 to 280 N9316212 363<br />
0.25 15 1.00 -20 to 260/280 N9316213 363<br />
0.25 30 0.25 -20 to 280 N9316214 619<br />
0.25 30 1.00 -20 to 260/280 N9316215 619<br />
0.25 60 0.25 -20 to 280 N9316216 1065<br />
0.25 60 1.00 -20 to 260/280 N9316217 1065<br />
0.32 15 0.25 -20 to 280 N9316218 402<br />
0.32 30 0.25 -20 to 280 N9316220 670<br />
0.32 60 0.25 -20 to 280 N9316222 1173<br />
0.32 15 1.00 -20 to 260/280 N9316219 402<br />
0.32 30 1.00 -20 to 260/280 N9316221 670<br />
0.32 60 1.00 -20 to 260/280 N9316223 1173<br />
0.45* 15 0.85 -20 to 260/280 N9316224 395<br />
0.45* 30 0.85 -20 to 260/280 N9316225 740<br />
0.53 15 1.00 -20 to 260/280 N9316226 395<br />
0.53 30 1.00 -20 to 260/280 N9316227 636<br />
Elite-1701<br />
(14% – Cyanopropylphenyl) –<br />
Methylpolysiloxane<br />
Inner Film Temperature<br />
Diameter Length Thickness Limits<br />
(mm i.d.) (m) (μm) (°C) Part No. Each (€)<br />
0.05 10 0.05 -20 to 280 N9316257 650<br />
0.05 10 0.20 -20 to 280 N9316258 650<br />
0.10 20 0.10 -20 to 280 N9316259 547<br />
0.10 20 0.40 -20 to 270/280 N9316260 625<br />
0.18 10 0.40 -20 to 270/280 N9316228 332<br />
0.18 20 0.40 -20 to 270/280 N9316229 523<br />
0.25 15 0.15 -20 to 280 N9316230 318<br />
0.25 15 0.25 -20 to 280 N9316231 363<br />
0.25 15 1.00 -20 to 260/280 N9316232 363<br />
0.25 30 0.25 -20 to 260/280 N9316234 547<br />
0.25 30 1.00 -20 to 260/280 N9316235 547<br />
0.25 60 0.15 -20 to 280 N9316236 1065<br />
0.25 60 0.25 -20 to 280 N9316237 1057<br />
(€)<br />
0.25 60 1.00 -20 to 260/280 N9316238 930<br />
0.32 15 0.15 -20 to 280 N9316239 402<br />
0.32 15 0.25 -20 to 280 N9316240 402<br />
0.32 15 1.00 -20 to 260/280 N9316241 402<br />
0.32 30 0.15 -20 to 280 N9316242 573<br />
0.32 30 0.25 -20 to 280 N9316243 573<br />
0.32 30 1.00 -20 to 260/280 N9316244 573<br />
0.32 50 1.00 -20 to 260/280 N9316245 828<br />
0.32 60 0.15 -20 to 280 N9316246 1173<br />
0.32 60 0.25 -20 to 280 N9316247 828<br />
0.32 60 1.00 -20 to 260/280 N9316248 1019<br />
0.45* 15 0.42 -20 to 260/270 N9316250 395<br />
0.45* 15 0.85 -20 to 250/270 N9316249 395<br />
0.45* 30 0.42 -20 to 260/270 N9316252 740<br />
0.45* 30 0.85 -20 to 250/270 N9316251 740<br />
0.53 15 1.00 -20 to 250/270 N9316253 356<br />
0.53 15 0.50 -20 to 260/270 N9316254 395<br />
0.53 30 0.50 -20 to 260/270 N9316256 740<br />
0.53 30 1.00 -20 to 250/270 N9316255 740<br />
Elite-BAC Blood Alcohol Analysis<br />
Columns for GC and High-Speed<br />
Headspace Gas Chromatography<br />
Now using the PerkinElmer Blood Alcohol columns,<br />
standard separations and automated separations of less than<br />
1.5 minutes can be accomplished. Sample concentrations<br />
range from 0.01 to 0.05% with quantitative precision<br />
of
Capillary Columns<br />
PerkinElmer Elite Series Capillary Columns<br />
Elite-CLPesticides<br />
Elite-CLPesticides is specially designed to overcome the<br />
coelutions and analyte breakdown typically encountered in<br />
chlorinated pesticide analyses for U.S. EPA methods 8081,<br />
608, and CLP. Column bleed measured by ECD is extremely<br />
low at temperatures greater than 300 °C, which is critical for<br />
baking out the column to remove high-boiling compounds<br />
commonly found in pesticide/PCB extracts.<br />
Gas Chromatography Capillary Columns<br />
Primary Applications<br />
Chlorinated Pesticides and Herbicides. U.S. EPA Methods<br />
504, 608, 619, 8081, 8151, and CLP.<br />
Features and Benefits:<br />
■ Thermally stable to 340 °C<br />
■ Low column bleed – ideal for ECD or GC/MS analysis<br />
■ Exceeds performance criteria for U.S. EPA Methods<br />
8081, 608, CLP<br />
■ Baseline separation in less than 15 minutes<br />
Inner<br />
Film<br />
Diameter Length Thickness<br />
(mm i.d.) (m) (μm) Part No. Each (€)<br />
0.25 15 0.25 N9316661 432<br />
0.25 30 0.25 N9316662 636<br />
0.32 15 0.50 N9316663 458<br />
0.32 30 0.50 N9316664 687<br />
0.53 15 0.50 N9316665 483<br />
0.53 30 0.50 N9316666 764<br />
Elite-CLPesticides 2<br />
Inner<br />
Film<br />
Diameter Length Thickness<br />
(mm i.d.) (m) (μm) Part No. Each (€)<br />
0.25 15 0.20 N9316667 432<br />
0.25 30 0.20 N9316668 624<br />
0.32 15 0.25 N9316669 483<br />
0.32 30 0.25 N9316670 687<br />
0.53 15 0.42 N9316671 483<br />
0.53 30 0.42 N9316672 764<br />
126
Capillary Columns<br />
PerkinElmer Elite Series Capillary Columns<br />
Elite-FFAP Nitroterephthalic<br />
Acid Modified Polyethylene<br />
Glycol (Bonded)<br />
Inner Film Temperature<br />
Diameter Length Thickness Limits<br />
(mm i.d.) (m) (μm) (°C) Part No. Each (€)<br />
Elite-SimDist<br />
Dimethylpolysiloxane Processed<br />
for Simulated Distillation<br />
Inner Film Temperature<br />
Diameter Length Thickness Limits<br />
(mm i.d.) (m) (μm) (°C) Part No. Each (€)<br />
0.25 15 0.25 40 to 250 N9316351 318<br />
0.25 30 0.25 40 to 250 N9316352 547<br />
0.32 15 0.25 40 to 250 N9316353 356<br />
0.32 30 0.25 40 to 250 N9316354 547<br />
0.45* 15 0.85 40 to 240/250 N9316355 356<br />
0.45* 30 0.85 40 to 240/250 N9316356 721<br />
0.53 15 1.00 40 to 240/250 N9316357 402<br />
0.53 30 1.00 40 to 240/250 N9316358 611<br />
Elite-HT SimDist<br />
for High-Temperature<br />
Simulated Distillation<br />
Inner Film Temperature<br />
Diameter Length Thickness Limits<br />
(mm i.d.) (m) (μm) (°C) Part No. Each (€)<br />
0.53 6 0.15 -60 to 400 N9316572 318<br />
Elite-MTBE Low Polarity<br />
Stationary Phase<br />
Inner Film Temperature<br />
Diameter Length Thickness Limits<br />
(mm i.d.) (m) (μm) (°C) Part No. Each (€)<br />
0.45 30 2.55 10 to 250 N9316520 797<br />
0.53 30 3.00 10 to 250 N9316521 797<br />
Elite-PONA Dimethylpolysiloxane<br />
Processed for Detailed Analysis<br />
of Petroleum Naphtha<br />
Inner Film Temperature<br />
Diameter Length Thickness Limits<br />
(mm i.d.) (m) (μm) (°C) Part No. Each (€)<br />
0.25 100 0.50 -60 to 300/320 N9316015 1057<br />
0.20 50 0.50 -60 to 300/320 N9316065 764<br />
Elite-RX for Analysis<br />
of Drugs of Abuse<br />
Inner Film Temperature<br />
Diameter Length Thickness Limits<br />
(mm i.d.) (m) (μm) (°C) Part No. Each (€)<br />
Phase: Elite-1-RX<br />
0.20 12 0.33 -60 to 330/350 N9316345 325<br />
0.20 25 0.33 -60 to 330/350 N9316346 445<br />
Phase: Elite-5ms-RX<br />
0.20 12 0.33 -60 to 330/350 N9316349 344<br />
0.20 25 0.33 -60 to 330/350 N9316350 483<br />
Phase: Elite-17-RX<br />
0.20 12 0.33 40 to 330/320 N9316347 325<br />
0.20 25 0.33 40 to 330/320 N9316348 445<br />
0.45* 10 2.55 -60 to 360 N9316261 281<br />
0.53 10 3.00 -60 to 360 N9316262 254<br />
Elite-TPH Specialty<br />
Phase for Analysis of<br />
Total Petroleum Hydrocarbons<br />
Inner Film Temperature<br />
Diameter Length Thickness Limits<br />
(mm i.d.) (m) (μm) (°C) Part No. Each (€)<br />
0.32 30 0.25 -10 to 320 N9316386 611<br />
0.45* 30 1.00 -10 to 290 N9316387 752<br />
Elite-VMS<br />
Inner Film Temperature<br />
Diameter Length Thickness Limits<br />
(mm i.d.) (m) (μm) (°C) Part No. Each (€)<br />
0.18 20 1.00 -40 to 240/260 N9316650 547<br />
0.18 40 1.00 -40 to 240/260 N9316651 942<br />
0.25 30 1.40 -40 to 240/260 N9316652 624<br />
0.25 60 1.40 -40 to 240/260 N9316653 1019<br />
0.32 30 1.80 -40 to 240/260 N9316654 675<br />
0.32 60 1.80 -40 to 240/260 N9316655 1121<br />
0.45 30 2.55 -40 to 240/260 N9316656 764<br />
0.45 60 2.55 -40 to 240/260 N9316657 1223<br />
0.53 30 3.00 -40 to 240/260 N9316658 764<br />
0.53 60 3.00 -40 to 240/260 N9316659 1223<br />
0.53 75 3.00 -40 to 240/260 N9316660 1338<br />
Elite-Volatiles Specialty Phase<br />
for Analysis of Volatile<br />
Organic Compounds<br />
Inner Film Temperature<br />
Diameter Length Thickness Limits<br />
(mm i.d.) (m) (μm) (°C) Part No. Each (€)<br />
0.25 30 1.40 -20 to 240 N9316388 638<br />
0.25 60 1.40 -20 to 240 N9316389 802<br />
0.32 30 1.80 -20 to 240 N9316390 714<br />
0.32 60 1.80 -20 to 240 N9316391 1083<br />
0.45* 30 2.55 -20 to 240 N9316392 764<br />
0.45* 75 2.55 -20 to 240 N9316393 1274<br />
* Ferrule size same as 0.53<br />
Capillary Columns Gas Chromatography<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
127
Capillary Columns<br />
PerkinElmer Elite Series Capillary Columns<br />
Gas Chromatography Capillary Columns<br />
Elite-MWAX<br />
Inner Film Temperature<br />
Diameter Length Thickness Limits<br />
(mm i.d.) (m) (μm) (°C) Part No. Each (€)<br />
0.53 30 1.00 20 to 240/250 N9316478 721<br />
Elite-WAX Polyethylene Glycol<br />
Inner Film Temperature<br />
Diameter Length Thickness Limits<br />
(mm i.d.) (m) (μm) (°C) Part No. Each (€)<br />
0.05 10 0.05 20 to 240/250 N9316430 650<br />
0.05 10 0.10 20 to 240/250 N9316431 650<br />
0.10 10 0.10 20 to 240/250 N9316432 574<br />
0.10 10 0.20 20 to 240/250 N9316433 574<br />
0.10 20 0.10 20 to 240/250 N9316434 625<br />
0.10 20 0.20 20 to 240/250 N9316435 625<br />
0.18 10 0.18 20 to 240/250 N9316394 332<br />
0.18 10 0.30 20 to 240/250 N9316395 332<br />
0.18 20 0.18 20 to 240/250 N9316396 523<br />
0.18 40 0.30 20 to 250/260 N9316398 944<br />
0.25 15 0.15 20 to 250 N9316399 357<br />
0.25 15 0.25 20 to 250 N9316400 357<br />
0.25 15 0.50 20 to 250 N9316401 356<br />
0.25 30 0.15 20 to 250 N9316402 606<br />
0.25 30 0.25 20 to 250 N9316403 547<br />
0.25 30 0.50 20 to 250 N9316404 547<br />
0.25 60 0.15 20 to 250 N9316405 1019<br />
0.25 60 0.25 20 to 250 N9316406 738<br />
0.25 60 0.50 20 to 250 N9316407 930<br />
0.32 15 0.15 20 to 250 N9316408 389<br />
0.32 15 0.25 20 to 250 N9316409 389<br />
0.32 15 0.50 20 to 250 N9316410 389<br />
0.32 30 0.15 20 to 250 N9316411 644<br />
0.32 30 0.25 20 to 250 N9316412 573<br />
0.32 30 0.50 20 to 250 N9316413 573<br />
0.32 60 0.25 20 to 250 N9316416 993<br />
0.32 60 0.50 20 to 250 N9316417 993<br />
0.45* 5 1.70 50 to 230 N9316418 147<br />
0.45* 15 0.42 20 to 250 N9316420 402<br />
0.45* 15 0.85 20 to 240/250 N9316419 402<br />
0.45* 30 0.42 20 to 250 N9316422 721<br />
0.45* 30 0.85 20 to 240/250 N9316421 721<br />
0.45* 60 0.85 20 to 240/250 N9316423 1148<br />
0.53 15 0.50 20 to 250 N9316426 402<br />
0.53 15 1.00 20 to 240/2540 N9316425 356<br />
0.53 30 0.50 20 to 250 N9316428 721<br />
0.53 30 1.00 20 to 240/250 N9316427 611<br />
0.53 60 1.00 20 to 240/250 N9316429 1019<br />
Elite-WAX ETR<br />
(Extended Temperature Range)<br />
Polyethylene Glycol<br />
Inner Film Temperature<br />
Diameter Length Thickness Limits<br />
(mm i.d.) (m) (μm) (°C) Part No. Each (€)<br />
0.25 15 0.25 40 to 250 N9316547 363<br />
0.25 15 0.50 40 to 250 N9316548 363<br />
0.25 30 0.25 40 to 250 N9316549 612<br />
0.25 30 0.50 40 to 250 N9316550 612<br />
0.25 60 0.25 40 to 250 N9316551 1071<br />
0.32 15 0.25 40 to 250 N9316552 396<br />
0.32 15 0.50 40 to 250 N9316553 396<br />
0.32 15 1.00 40 to 240/250 N9316554 396<br />
0.32 30 0.25 40 to 260 N9316555 676<br />
0.32 30 0.50 40 to 250 N9316556 676<br />
0.32 30 1.00 40 to 240/250 N9316557 547<br />
0.32 50 1.00 40 to 240/250 N9316558 828<br />
0.32 60 0.25 40 to 250 N9316559 1180<br />
0.32 60 0.50 40 to 250 N9316560 1180<br />
0.32 60 1.00 40 to 240/250 N9316561 993<br />
0.45 5 1.70 40 to 230/250 N9316562 147<br />
0.45 15 0.85 40 to 240 N9316563 396<br />
0.45 30 0.85 40 to 240 N9316564 746<br />
0.45 60 0.85 40 to 240 N9316565 1193<br />
0.53 5 2.00 40 to 220/230 N9316566 147<br />
0.53 15 1.00 40 to 240/250 N9316567 395<br />
0.53 15 2.00 40 to 220/230 N9316568 396<br />
0.53 30 1.00 40 to 240/250 N9316569 611<br />
0.53 30 2.00 40 to 220/230 N9316570 746<br />
0.53 60 1.00 40 to 240/250 N9316571 1192<br />
* Ferrule size same as 0.53<br />
Elite-XLB Specialty Phase<br />
for GC/MS with<br />
Exceptionally Low Bleed<br />
Inner Film Temperature<br />
Diameter Length Thickness Limits<br />
(mm i.d.) (m) (μm) (°C) Part No. Each (€)<br />
0.18 20 0.18 30 to 340/360 N9316480 548<br />
0.20 12 0.33 30 to 340/360 N9316496 351<br />
0.20 25 0.33 30 to 340/360 N9316497 536<br />
0.25 15 0.25 30 to 340/360 N9316481 402<br />
0.25 15 1.00 30 to 340/360 N9316482 402<br />
0.25 30 0.10 30 to 340/360 N9316483 636<br />
0.25 30 0.25 30 to 340/360 N9316484 611<br />
0.25 30 1.00 30 to 340/360 N9316485 636<br />
0.25 60 0.25 30 to 340/360 N9316487 1019<br />
0.32 15 0.25 30 to 340/360 N9316488 421<br />
0.32 30 0.10 30 to 340/360 N9316489 695<br />
0.32 30 0.25 30 to 340/360 N9316490 636<br />
0.32 30 0.50 30 to 340/360 N9316492 674<br />
0.32 30 1.00 30 to 340/360 N9316491 674<br />
0.32 60 0.25 30 to 340/360 N9316493 1057<br />
0.53 15 1.50 30 to 320/340 N9316494 445<br />
0.53 30 1.50 30 to 320/340 N9316495 759<br />
128
Capillary Columns<br />
PerkinElmer Elite Series Guard and PLOT Columns<br />
Elite Guard Columns<br />
Elite-Alumina/KCI* PLOT<br />
Guard Columns<br />
Maintain the integrity of your capillary column<br />
with a fused silica Guard Column.<br />
Using the Elite-Guard or Elite-Siltek Guard Column<br />
lengthens the life of the capillary column and improves the<br />
analyte focusing. The 5 m length of deactivated uncoated<br />
fused silica is connected to the inlet end of the capillary<br />
column and traps nonvolatile residues, preventing them<br />
from collecting at the head of the analytical column. This<br />
length of fused silica contains no stationary phase, adding<br />
only a minimal amount of time to the analysis.<br />
PerkinElmer offers both the Intermediate-polarity deactivated<br />
guard column and the Siltek deactivated guard column<br />
as it is important to match the polarity of the solvent<br />
and the polarity of the surface deactivation. The Elite-Guard<br />
intermediate polarity deactivated column has an operating<br />
temperature up to 325 °C. Siltek deactivation creates a<br />
highly inert surface for very active compounds such as<br />
chlorinated pesticides with a maximum temperature<br />
range up to 380 °C.<br />
Features and Benefits:<br />
■ Increases the life of the capillary column<br />
■ Maintains retention time and resolution on capillary column<br />
■ Traps nonvolatile particles<br />
■ Improves column performance<br />
■ Elite-Guard temperature range to 325 °C<br />
■ Elite-Siltek Guard temperature range to 380 °C<br />
Elite-Guard<br />
Inner<br />
Diameter Length<br />
(mm i.d.) (m) Part No. Each (€)<br />
0.10 5 N9316601 106<br />
0.18 5 N9316602 70<br />
0.25 5 N9316603 56<br />
0.32 5 N9316604 64<br />
0.45 5 N9316605 84<br />
0.53 5 N9316606 84<br />
Elite-Siltek Guard<br />
Inner<br />
Diameter Length<br />
(mm i.d.) (m) Part No. Each (€)<br />
0.25 5 N9316607 70<br />
0.32 5 N9316608 77<br />
0.53 5 N9316609 106<br />
Inner Film Temperature<br />
Diameter Length Thickness Limits<br />
(mm i.d.) (m) (μm) (°C) Part No. Each (€)<br />
0.53 50 N/A up to 200 N9316544 802<br />
* Lower Polarity than Elite Alumina.<br />
Elite-Alumina PLOT Phase for<br />
Analysis of Light Hydrocarbons<br />
Inner Film Temperature<br />
Diameter Length Thickness Limits<br />
(mm i.d.) (m) (μm) (°C) Part No. Each (€)<br />
0.53 30 N/A -60 to 200 N9316304 636<br />
0.53 50 N/A -60 to 200 N9316305 1019<br />
Note: -60 °C is the lowest temperature used on this phase in our lab.<br />
Lower temperatures may be used depending on the sample.<br />
Elite-Cyclosil B PLOT for Chiral Separations<br />
Inner Film Temperature<br />
Diameter Length Thickness Limits<br />
(mm i.d.) (m) (μm) (°C) Part No. Each (€)<br />
0.25 30 0.25 35 to 230 N9316545 650<br />
0.32 30 0.25 35 to 230 N9316546 649<br />
Elite-Molesieve PLOT Phase for<br />
Analysis of Permanent Gases<br />
Inner Film Temperature<br />
Diameter Length Thickness Limits<br />
(mm i.d.) (m) (μm) (°C) Part No. Each (€)<br />
0.53 30 N/A -60 to 300 N9316361 611<br />
Note: -60 °C is the lowest temperature used on this phase in our lab.<br />
Lower temperatures may be used depending on the sample.<br />
Elite-Q PLOT Phase for Analysis of<br />
Light Gases and Hydrocarbons<br />
Inner Film Temperature<br />
Diameter Length Thickness Limits<br />
(mm i.d.) (m) (μm) (°C) Part No. Each (€)<br />
0.32 30 N/A -60 to 250 N9316359 509<br />
0.53 30 N/A -60 to 250 N9316360 636<br />
Note: -60 °C is the lowest temperature used on this phase in our lab.<br />
Lower temperatures may be used depending on the sample.<br />
Capillary Columns Gas Chromatography<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
129
Capillary Columns<br />
PerkinElmer Packed Columns<br />
Packed Columns<br />
Packed Packed Empty Empty<br />
Length o.d. 2 mm i.d. 4 mm i.d. 2 mm i.d. 4 mm i.d.<br />
Instrument Type Material Shape (ft.) (in.) Part No. Each (€) Part No. Each (€) Part No. Each (€) Part No. Each (€)<br />
Gas Chromatography Capillary Columns<br />
AutoSystem GC Stainless 3 1/8 N9305012 126 N9304012 87<br />
Clarus Steel 6 1/8 N9305013 165 N9304013 88<br />
(not on-column) 12 1/8 N9305014 254 N9304014 101<br />
3 1/4<br />
6 1/4 N9305016 228 N9304016 88<br />
12 1/4 N9305017 356 N9304017 134<br />
Glass 3 1/4 N9305018 228 N9304018 114 N9304021 114<br />
6 1/4 N9305019 190 N9305022 292 N9304019 114 N9304022 114<br />
12 1/4 N9304020 325 N9304023 325<br />
AutoSystem GC/XL Glass 3 1/4 N9304046 126<br />
(on-column) 6 1/4 N9305047 255 N9304047 126<br />
12 1/4 N9305048 332 N9304048 268<br />
Note: Stainless steel columns are metal-fitted at both ends to contain the packing.<br />
For on-column applications, please request glass wool plugs instead of metal frits when ordering.<br />
Choose the appropriate part number from table above. Follow form at bottom of page to choose support material, % liquid<br />
phase, and mesh size. This information is required to place an order.<br />
130
Detectors<br />
Electron Capture Detectors (ECD)<br />
Add-On Kit<br />
The ECD is a versatile, nondestructive detector which<br />
responds strongly to halogen-containing compounds as<br />
well as to certain other electron-capturing substances. The<br />
ECD’s high sensitivity and selectivity make it an ideal<br />
choice for pesticide-residue analysis and for detection<br />
of halogen-derivatized compounds.<br />
The ECD has an independent temperature range of 100 -<br />
450 °C. The detector contains thermal protection that<br />
prevents heating the Ni 63 source to temperatures beyond<br />
safe operating limits. Two ECDs can be installed and<br />
operated simultaneously on the AutoSystem Series and<br />
Clarus GCs. Nitrogen or argon/methane is the required<br />
detector operating gas. The base of the detector terminates<br />
in a 1/8 in. fitting.<br />
To Amplifier<br />
ECD Add-On Kit (Manual Pneumatics)<br />
Kit includes all parts necessary to install an ECD on the<br />
AutoSystem Series or Clarus GCs. Includes detector,<br />
heater, sensor, heater block, 1/16 in. makeup gas line,<br />
makeup gas needle valve, and vent tube assembly.<br />
Requires but does not include ECD amplifier (N6120014).<br />
Installation by PerkinElmer Service is recommended.<br />
Voltage Part No. Each (€)<br />
120 V AutoSystem N6120011<br />
240 V AutoSystem N6120026 5400<br />
120 V Clarus N6520020<br />
230 V Clarus N6520021 3136<br />
ECD Amplifier<br />
Required for use with ECD detector<br />
with add-on kit.<br />
Collector Anode<br />
ECD Add-On Kit (PPC Pneumatics)<br />
Kit includes detector, heater, sensor, heater block, and<br />
programmable pneumatic control for makeup gas. Requires,<br />
but does not include, ECD amplifier (N6120014). The<br />
AutoSystem XL or Clarus GCs must be PPC ready. If not,<br />
a PPC upgrade kit (N6120146) is required. (See page 166<br />
for more information.) Installation by PerkinElmer Service<br />
is required, but not included.<br />
Voltage Part No. Each (€)<br />
120 V N6120122<br />
230 V N6120123 4037<br />
Vent Tube Assembly<br />
Flexible tube to safely vent<br />
toxic sample effluent.<br />
Column Adapters<br />
Capillary Column Adapter/Receiver<br />
Ni 63 Foil (Source)<br />
Adapter converts 1/8 in. fitting to<br />
1/16 in. for use with capillary columns.<br />
Note: Glass-lined tubing reduces background from<br />
polyimide coating in high-temperature applications.<br />
Part No.<br />
N6000968<br />
Each (€)<br />
249<br />
Makeup Gas In<br />
Column Connection<br />
Part No.<br />
Each (€)<br />
N6120014 712<br />
PID/ECD Series Operation Kit<br />
Kit for directing effluent from<br />
PID to ECD.<br />
1/4 in. Packed Column Adapter<br />
For use with 1/4 in. packed columns.<br />
1/8 to 1/4 in. adapters fit both injector<br />
and detector ends. (Pkg. 2)<br />
ECD Wipe Test Kit<br />
Part No.<br />
Part No.<br />
Each (€)<br />
N6120059 293<br />
Part No.<br />
Each (€)<br />
N6100161 47<br />
Each (€)<br />
00080100 172<br />
U.S. Federal law requires that all ECDs be wipe-tested<br />
periodically as described in the instrument operator’s<br />
manual. In the U.S., possession and use of ECD is regulated<br />
by N.R.C. and/or state regulatory agencies. Licensing by<br />
regulatory agencies is required. Outside of the U.S., check<br />
with governing bodies for licensing and regulations<br />
covering possession and use. This kit contains everything<br />
necessary to do a complete wipe test. For use on any<br />
model GC ECD.<br />
Part No. Each (€)<br />
00091667 6<br />
Detectors Gas Chromatography<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
131
Detectors<br />
Flame Ionization Detector (FID) Auto-Ignite<br />
Gas Chromatography Detectors<br />
Add-On Kits<br />
Auto-Ignite FID with PPC Add-On Kit<br />
Kit includes detector assembly with heater and sensor,<br />
heater block, igniter, programmable pneumatics, and<br />
controls for detector combustion gases. Requires but does<br />
not include amplifier (N6120162) and AutoSystem XL<br />
firmware revision 3.3 or higher. The AutoSystem XL must<br />
be PPC ready. If not, a PPC upgrade kit (N6120146)<br />
is required.<br />
Note: AutoSystem XL GCs shipped prior to January 1997 require a new<br />
detector cover. Installation by PerkinElmer Service is required, but not included.<br />
Voltage Part No. Each (€)<br />
120 V N6120167<br />
240 V N6120168 3172<br />
Auto-Ignite FID Add-On Kit (Manual Pneumatics)<br />
Kit includes detector assembly with heater and sensor,<br />
heater block, igniter, hydrogen pressure regulator, and<br />
needle valve. Requires, but does not include, amplifier<br />
(N6120162). Requires AutoSystem XL to have firmware<br />
revision 3.3 or higher.<br />
Note: AutoSystem XL GCs shipped prior to January 1997 require a new<br />
detector cover (N6103151).<br />
Voltage Part No. Each (€)<br />
120 V AutoSystem N6120165<br />
240 V AutoSystem N6120166 4158<br />
120 V Clarus N6520018<br />
230 V Clarus N6520019 1762<br />
FID Amplifier<br />
Required for use with<br />
FID Detector Add-On Kit.<br />
Auto-Ignite FID<br />
Replacement Parts<br />
1<br />
2<br />
3<br />
4<br />
5<br />
6<br />
7<br />
8<br />
9<br />
Part No.<br />
Each (€)<br />
N6120162 754<br />
Description Part No. Each (€)<br />
Collector Head Assembly N6100357 1161<br />
Silicone Rubber O-Ring* (not shown) 09902143 1<br />
Polarizer Nozzle N6103167 49<br />
Spring Washer 09907827 1<br />
Nozzle Insulator N6101085 59<br />
Nozzle Collector N6103175 55<br />
FID Jet Contact/Spring N6001204 10<br />
Jet Assembly N6100361 301<br />
FID Body N6100364 573<br />
Nozzle Assembly N6100430 199<br />
Detector Series Operation Kit<br />
TCD/FID Series Operation Kit<br />
Used to direct sample effluent<br />
from the TCD to the FID.<br />
PID/FID Series Operation Kit<br />
Used to direct sample effluent<br />
from the PID to the FID.<br />
FID Miscellaneous Accessories<br />
Description Part No. Each (€)<br />
Auto-Ignite Nozzle Replacement Tool N6103188 17<br />
For removing nozzle from auto-ignite FID body<br />
Auto-Ignite FID Catalytic Reactor Accessory N6120161 612<br />
Capillary Column Adapter N6120020 69<br />
For capillary column use with the<br />
FID 1/8 to 1/16 in. detector adapter<br />
Ceramic Column Cutter N9301376 59<br />
Cotton Applicators N9301272 4<br />
Detector Cover (Brown Color) N6103225 43<br />
Detector Cover (White Color) N6103151 43<br />
Eraser Brush-Pencil 09923078 64<br />
Jet Assembly N6100194 376<br />
Jet Replacement Tool N6101297 51<br />
1/4 in. nut driver for removing jet<br />
from auto-ignite FID body<br />
Quartz Wool N6102354 26<br />
Replacement Stainless Steel Glow Plug N6103089 9<br />
for Auto-ignite FID<br />
Septa, low bleed (pkg. 50)** N9302972 103<br />
1/4 in. Packed Column Adapter 00080100 172<br />
For use with 1/4 in. packed columns. 1/8 to 1/4 in.<br />
adapter fits both injector and detector ends<br />
** For more Septa see page 159.<br />
1<br />
*<br />
8<br />
Part No.<br />
2<br />
3<br />
4<br />
5<br />
6<br />
7<br />
Each (€)<br />
N6120006 166<br />
Part No.<br />
Each (€)<br />
N6120059 293<br />
9<br />
132
Detectors<br />
Flame Ionization Detector (FID) External Igniter<br />
Add-On Kits<br />
2<br />
External Igniter FID with PPC Add-On Kit<br />
Kit includes detector, heater and sensor, heater block,<br />
igniter, programmable pneumatics, and controls for<br />
detector combustion gases. Requires but does not include<br />
FID amplifier (N6120162). The AutoSystem XL must be<br />
PPC ready. If not, PPC upgrade kit (N6120146) is required.<br />
(See page 166 for more information.) Installation by<br />
PerkinElmer Service is required, but not included.<br />
1<br />
*<br />
Voltage Part No. Each (€)<br />
120 V N6120120<br />
230 V N6120121 4489<br />
3<br />
4<br />
External Igniter FID Add-On Kit (Manual Pneumatics)<br />
Kit includes detector assembly with heater and sensor,<br />
heater block, igniter, hydrogen pressure regulator,<br />
and air needle valve. Requires, but does not include,<br />
FID amplifier board (N6120162).<br />
Voltage Part No. Each (€)<br />
120 V N6120010<br />
240 V N6120024 2516<br />
FID Amplifier<br />
Required for use with FID<br />
Detector Add-On Kit.<br />
Replacement Parts<br />
1<br />
2<br />
3<br />
4<br />
5<br />
6<br />
7<br />
8<br />
9<br />
Part No.<br />
Each (€)<br />
N6120162 754<br />
Description Part No. Each (€)<br />
Collector Head Assembly N6100170 574<br />
*Collector Assembly O-Ring (not shown) 09902143 1<br />
Collector Cap N6101037 17<br />
Nozzle Insulator N6101085 59<br />
Nozzle Ring 09912223 1<br />
FID Nozzle N6101100 59<br />
FID Jet Contact N6001204 10<br />
Jet Assembly N6100038 147<br />
Polarizer Replacement Kit N9300089 65<br />
FID Body N6100037 682<br />
Collector Adapter, Teflon ® ** (not shown) N6101547 43<br />
** Note: If instrument was purchased prior to March 1993, the following<br />
items must also be ordered: one each of N6101546 and 09912223.<br />
9<br />
5<br />
6<br />
7<br />
8<br />
Detectors Gas Chromatography<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
133
Detectors<br />
Flame Ionization Detector (FID) Replacement Parts<br />
Gas Chromatography Detectors<br />
Catalytic Reactor Accessory<br />
The catalytic reactor converts CO and CO2 to methane<br />
conveniently and efficiently. The lower detection limit<br />
is extended to well below 0.1 ppm.<br />
The catalytic reactor consists of a special catalytic reactor<br />
base which replaces the FID base. The reactor body<br />
contains a quantity of catalyst held in place by a quartz<br />
wool plug.<br />
Kits include base assembly, reactor tube, and instructions.<br />
External Igniter FID Catalytic<br />
Reactor Accessory<br />
Auto-Ignite FID Catalytic<br />
Reactor Accessory<br />
Catalytic Reactor Replacement Parts<br />
Description Part No. Each (€)<br />
Catalyst N9302698 55<br />
Jet Assembly N6100194 376<br />
Quartz Wool N6102354 26<br />
Catalyst<br />
Part No.<br />
Each (€)<br />
N6120070 810<br />
Part No.<br />
FID Base<br />
Each (€)<br />
N6120161 612<br />
Miscellaneous Accessories<br />
External Ignite Nozzle Replacement Tool<br />
For removing nozzle from<br />
External Ignite FID body.<br />
Hydrogen Regulator<br />
Replacement Kit<br />
Hydrogen/Air Replacement<br />
Needle Valve<br />
Igniter Assembly<br />
Complete replacement igniter<br />
assembly with glow plug.<br />
Replacement Glow Plug<br />
for External Ignite FID<br />
FID Flow Measurement Adapter<br />
Part No.<br />
Each (€)<br />
N6100102 125<br />
Part No.<br />
Each (€)<br />
N6100289 548<br />
Part No.<br />
Each (€)<br />
N6101412 396<br />
Part No.<br />
Each (€)<br />
N6100016 191<br />
Part No.<br />
Each (€)<br />
00091279 6<br />
Part No.<br />
Each (€)<br />
N6101345 29<br />
134
Detectors<br />
Flame Photometric Detector (FPD)<br />
Add-On Kits<br />
The FPD is a highly sensitive and selective detector for both<br />
sulfur and phosphorus compounds. It is especially suitable<br />
for environmental monitoring of H 2 S and sulfur gases in<br />
general and for organophosphorus compounds present at<br />
trace levels in pesticide analysis. Alkyl tin compounds can<br />
also be analyzed by changing the filter assembly. The sulfur<br />
filter is shipped standard.<br />
The FPD mounts in either the front or rear detector position.<br />
This allows many detector combinations, such as FPD/FPD,<br />
FPD/TCD, and FPD/ELCD.<br />
The AutoSystem also includes a linearizer function for the<br />
sulfur mode and convenient control of the photomultiplier<br />
tube from the keyboard.<br />
The FPD is capillary-column compatible. The detector will<br />
accept columns of 0.530 mm i.d. or less. The standard jet<br />
shipped with the FPD does not have a glass-lined tail pipe.<br />
If an all-glass system is required and glass packed columns<br />
will be used, then a glass-lined tail pipe should be ordered<br />
(N6100264). As a reminder, use of packed 1/4 in. columns<br />
requires a 1/8 to 1/4 in. adapter.<br />
Filters<br />
8<br />
Description Part No. Each (€)<br />
Phosphorus Lens (Yellow) N6000981 465<br />
Sulfur Lens* (Blue) N6000637 670<br />
Tin Lens (Orange) L4135472 721<br />
* Shipped standard.<br />
Filter Assembly<br />
5 2<br />
7<br />
Air<br />
1<br />
3<br />
4<br />
6<br />
Hydrogen<br />
FPD Add-On Kit (Manual Pneumatics)<br />
Kit includes detector, heater, sensor, heater block,<br />
hydrogen needle valve, air pressure regulator, and<br />
sulfur photomultiplier filter. Requires but does not<br />
include FPD amplifier (N6120095). Firmware revision<br />
1.6 or greater required. Firmware must be PerkinElmer<br />
Service installed. AutoSystem operator’s manual<br />
(09938559) revision E or higher required.<br />
Voltage Part No. Each (€)<br />
120 V AutoSystem N6120088<br />
240 V AutoSystem N6120089 8900<br />
120 V Clarus N6520028<br />
230 V Clarus N6520029 5400<br />
FPD Amplifier<br />
Firmware revision 1.6 or greater required. Firmware must<br />
be PerkinElmer Service installed. AutoSystem operator’s<br />
manual (09938559) revision E or higher required.<br />
FPD Replacement Parts for AutoSystem Series GCs<br />
1<br />
2<br />
3<br />
4<br />
5<br />
6<br />
7<br />
8<br />
Description Part No. Each (€)<br />
O-Ring 09902247 2<br />
Seal Assembly and Window N9300096 105<br />
(heat shield)<br />
Liner (window) N6003057 34<br />
FPD Body (upper) N6100243 650<br />
Window Holder N6003066 22<br />
FPD Jet, N6100245 128<br />
Glass-lined Jet Tailpipe N6100264 376<br />
(for all-glass system)<br />
FPD Body (lower) N6100244 612<br />
Photomultiplier Tube 09972321 1256<br />
FPD with PPC Add-On Kit<br />
Kit includes detector, heater, sensor, heater block,<br />
programmable pneumatic control for detector combustion<br />
gases, and sulfur photomultiplier filter. Requires but does<br />
not include FPD amplifier (N6120095). AutoSystem XL GC<br />
must be PPC ready. If not, a PPC upgrade kit (N6120146)<br />
is required. (See page 166 for more information.)<br />
Installation by PerkinElmer Service is required,<br />
but not included.<br />
Voltage Part No. Each (€)<br />
120 V N6120128<br />
230 V N6120129 6700<br />
Packed Column Adapter<br />
1/8 to 1/4 in. adapter for use with<br />
1/4 in. packed columns. (Set of 2)<br />
Part No.<br />
Each (€)<br />
N6120095 660<br />
Part No.<br />
Each (€)<br />
00080100 172<br />
Detectors Gas Chromatography<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
135
Detectors<br />
Mass Spectrometer Detector<br />
The Clarus<br />
Mass Spectrometer<br />
The Clarus mass spectrometer is the fastest<br />
sampling and widest-mass-range quadrupole mass<br />
spectrometer available for GC/MS. State-of-the-art<br />
Pentium electronics process more scans across each<br />
peak, resulting in unmatched accuracy and precision,<br />
and better overall spectral fidelity. This, coupled<br />
with unique productivity tools, provides the<br />
functionality necessary to achieve optimum<br />
performance, completing work quickly, easily, and<br />
efficiently. The wide mass range and flexible data<br />
acquisition modes help tackle the most complex<br />
applications while rugged instrument design delivers<br />
maximum uptime, easy maintenance, and lower<br />
operating cost.<br />
Clarus Mass Spectrometer<br />
Combine the Clarus mass spectrometer with the<br />
Clarus gas chromatograph, market-leading<br />
TurboMatrix sample handling accessories, flexible<br />
user-friendly TotalChrom software, and worldclass<br />
service and support for an integrated,<br />
complete analytical solution from one familiar<br />
name – PerkinElmer. Whatever your application –<br />
Environmental, Chemical, Petrochemical, Flavor<br />
and Fragrance, Food, Beverage, Forensic,<br />
Pharmaceutical – PerkinElmer delivers the<br />
accuracy and precision you need.<br />
Flexible Column Choices<br />
Because the Clarus mass spectrometer allows a carrier gas flow of up to 5 mL<br />
per minute in EI, you have more column choices than with other GC/MS systems.<br />
Narrow-, medium-, and wide-bore columns can be used, with almost unlimited choice<br />
of stationary phase, diameter, and analytical method with Clarus mass spectrometer.<br />
Column Internal Diameter Typical Flows Clarus Mass Spectrometer Others<br />
Narrow-bore 0.10 to 0.18 mm i.d. 0.1 to 0.8 mL/min. X X<br />
Medium-bore 0.25 mm i.d 1 to 1.5 mL/min. X X<br />
Wide-bore* 0.32 to 0.53 mm i.d. 3 to 5 mL/min. X<br />
* Columns with low pneumatic impedance may require attachment of additional length of deactivated<br />
fused-silica capillary tubing to provide proper pressure drop from injector to mass spectrometer<br />
(Part Nos. N9301354, N9302149, and N9301343).<br />
Clarus Mass Spectrometer Benefits:<br />
■ Fastest Scan Rates – unprecedented speed with<br />
better chromatographic peak definition ensuring<br />
better quality results. Opens the use of quadrupole<br />
technology to fast GC applications.<br />
■ Widest Mass Range – uncompromised performance<br />
over a wide mass range.<br />
■ SIFI Scanning Mode – selected Ion Monitoring (SIM)<br />
and full scan in the same run resulting in the most<br />
complete characterization of the sample. No need<br />
to run the sample twice.<br />
■ Gold Component Technology – improved stability<br />
and reduced maintenance.<br />
■ Easy Access Ion Source – less than<br />
15-minute changeover.<br />
■ Sealed, Long-Life Photomultiplier – eliminates<br />
expensive replacement costs of electron multipliers.<br />
Better reliability.<br />
136
Detectors<br />
Mass Spectrometer Detector<br />
Cables<br />
Description Part No. Each (€)<br />
Cable, RS232, 7 ft. Length (185 cm) S5010025 46<br />
Personal Computer to AutoSystem XL Integral LINK<br />
(included with TurboMass Gold)<br />
Cable, RS232, 25 ft. Length (660 cm) S5010030 52<br />
Personal Computer to AutoSystem XL Integral LINK<br />
Computer to MS Cable E6400251 672<br />
For use with TurboMass Mass Spectrometers only<br />
Ethernet Cable 09991463 58<br />
For TurboMass Gold Mass and<br />
Clarus 500 Spectrometers only<br />
GC Start/Ready Cable E6400247 599<br />
GC to MS Interface Cable E6400242 1022<br />
Inner Source Replacement Parts<br />
Description Part No. Each (€)<br />
CI Ion Exit Plate E6401214 52<br />
Extra EI Electron Trap E6401220 137<br />
Extra CI Ion Volume E6401208 988<br />
Extra EI Ion Volume E6400211 1784<br />
Extra EI Repeller E6401219 242<br />
Ion Exit Plate E6401213 66<br />
Filament Assembly and Standard Tungsten Filament E6400209 220<br />
For use with TurboMass Spectrometers only<br />
Inner Source Heater Assembly E6400265 255<br />
Inner Source O-Ring Seal E5711272 22<br />
Inner Source Thumbscrew E6070836 6<br />
Standard Rhenium Filament N6470012 191<br />
Trap Contact E6401217 157<br />
Ionizer Replacement Parts<br />
Description Part No. Each (€)<br />
Clarus 500 and TurboMass Extra EI Inner source N6470207 2064<br />
Assembly (Tungsten)<br />
Clarus 500 and TurboMass Gold Extra EI Inner Ion E6400207 2171<br />
Source Assembly (Rhenium)<br />
Clarus 500 and TurboMass Gold Extra PCI/NCI E6400208 1615<br />
Inner Ion Source Assembly (Rhenium)<br />
Requires PCI or PCI/NCI configuration option<br />
Extra Outer Ion Source and Optics Assembly E6400206 4438<br />
Manuals<br />
Description Part No. Each (€)<br />
Clarus 500 MS Manual Set 09934562 179<br />
TurboMass Gold Manual Kit 09934472 257<br />
Includes: User’s Guide-EPCAS software,<br />
User’s Guide-EPCAS hardware, and TurboMass<br />
Gold Tutorial<br />
TurboMass Software User’s Manual S2701610 217<br />
TurboMass Hardware User’s Manual 09936341 96<br />
Miscellaneous Accessories<br />
BTO TM (Bleed Temperature Optimized) Injector Septa<br />
Maximum recommended operating<br />
temperature 300 °C. Low bleed,<br />
high temperature. 11 mm diameter.<br />
GC/MS Sensitivity Test Mix<br />
Includes standard solutions of benzophenone,<br />
hexachlorobenzene, and octafluoronaphthalene<br />
for testing instrument sensitivity.<br />
GC/MS Test Mix Triazine<br />
High molecular weight<br />
test standard. 100 mg.<br />
Forepump Vacuum Filter Kits<br />
Includes: Foreline Adsorption Trap (09923493), Nipple<br />
NW25 Extension Tube (09920864), NW25 Clamp Ring<br />
(09923491), NW25 Centering Ring (09923490), Installation<br />
Instructions (09936442), and<br />
Activated Alumina Reagentreplacement<br />
(09923504).<br />
Part No.<br />
E6420021<br />
Each (€)<br />
912<br />
Outlet Mist Filter<br />
Replacement Parts<br />
Description Part No. Each (€)<br />
Centering Ring 09923490 54<br />
Clamp 09923491 43<br />
Copper Tubing, Precleaned (50 ft.) N9300077 120<br />
FC-43 Tuning Compound N6212407 115<br />
Filament Allen Wrench 09907222 9<br />
Forepump Oil 09923492 117<br />
Gas Purifier for GC/MS N6471025 293<br />
Glass Bulb for Reference Gas E6401384 62<br />
Penning Gauge Spares Kit N6471031 1305<br />
Vacuum line (7 ft.) E6400223 1058<br />
Eraser Brush-Pencil 09923078 64<br />
Ceramic Column Cutter N9301376 59<br />
Cotton Applicators N9301272 4<br />
Septa, low bleed (pkg. 50)* N9302972 103<br />
* For more septa see page 159.<br />
Vent Kit<br />
Part No.<br />
Part No.<br />
Each (€)<br />
N9302972 103<br />
Each (€)<br />
E6401017 59<br />
Part No.<br />
Each (€)<br />
N9301730 107<br />
Part No.<br />
Each (€)<br />
09923518 643<br />
The Mass Spectrometer Vent Kit eliminates the introduction<br />
of oxygen, water vapor, and other airborne contaminants<br />
which can degrade sensitivity and performance of the mass<br />
spectrometer. The Clarus GCs should be vented with UHP<br />
nitrogen (99.9995%). Helium should not be used as Helium<br />
molecules penetrate the glass sleeve on the photomultiplier<br />
tube, compromising the vacuum<br />
and lowering sensitivity.<br />
Part No. Each (€)<br />
N6470045 446<br />
Detectors Gas Chromatography<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
137
Detectors<br />
Mass Spectrometer Detector<br />
Clarus MS<br />
TurboMass Single Additional Workstation License<br />
Allows TurboMass software to be run on one additional<br />
computer. Does not include manuals.<br />
Note: Network setup is the responsibility<br />
of the customer.<br />
Part No.<br />
S2701017<br />
Each (€)<br />
1512<br />
Wiley Mass Spectral Library<br />
Does not include the NIST library.<br />
Part No. Each (€)<br />
E6420003 6400<br />
Gas Chromatography Detectors<br />
MSVent Add-On Kit for the Clarus GC/MS<br />
Includes: all the necessary parts to add an MSVent<br />
accessory to a Clarus GC/MS. Requires a PreVent option<br />
(N6120144) to be already installed<br />
in the Clarus gas chromatograph. Part No. Each (€)<br />
Software<br />
TurboMass 5.1 Software Kit<br />
Includes: the TurboMass 5.1 software<br />
CD, TurboMass User’s Manual CD,<br />
and Utilities CD.<br />
Description Part No. Each (€)<br />
NIST Mass Spectral Library (2002) N6520220 2082<br />
NIST98 to 2002 Upgrade Kit N6520240 878<br />
Pfleger/Maurer/Weber Drug and Pesticide 04308523 4712<br />
Spectral Library<br />
TotalChrom Workstation Reprocess-Only Kit<br />
for TurboMass Mass Spectrometers Only<br />
N6120179 714<br />
Part No. Each (€)<br />
N6520206 1915<br />
Allows data collected from a conventional detector via<br />
TurboMass software to be analyzed with TotalChrom<br />
Workstation Chromatography Data System software.<br />
Includes: CD and 3.5 in. diskette<br />
media, user manuals, mouse pad,<br />
and installation instructions.<br />
Part No.<br />
S2701116<br />
Each (€)<br />
822<br />
Transfer Line<br />
Description Part No. Each (€)<br />
Transfer Line Carrier Tube E6401308 982<br />
Transfer Line O-Ring E5711269 11<br />
Transfer Lines 1/8 in. Nut E6401309 370<br />
Upgrade Kits<br />
EI to PCI/NCI Upgrade<br />
Includes: Cl ion source, reagent gas tubing, flow regulators,<br />
valves and solenoids, and dual-polarity electronic options.<br />
Installation by PerkinElmer Service<br />
is required, but not included.<br />
Part No. Each (€)<br />
TurboMass Gold Computer Upgrade<br />
Upgrade kit includes: Dell GX270 computer plus 17" flat<br />
panel monitor and Windows XP SP2.<br />
TurboMass 5.1 software is included free.<br />
Service installation is not required.<br />
Part No.<br />
N6470070<br />
Each (€)<br />
4285<br />
TurboMass Upgrade Kit<br />
E6420007 8600<br />
Upgrade kit includes: Dell GX270 computer with Windows<br />
XP SP2, 17" flat panel monitor, TurboMass 5.1 software<br />
and manual plus all necessary electronic and hardware<br />
components. Installation by a<br />
PerkinElmer Service professional<br />
is required, but not included.<br />
Part No.<br />
N6470080<br />
Each (€)<br />
10700<br />
138
Detectors<br />
Nitrogen Phosphorus Detector (NPD)<br />
Add-On Kits<br />
Replacement Parts<br />
NPD Add-On Kit (Manual Pneumatics)<br />
Description Part No. Each (€)<br />
The NPD can be used for the analysis of organic compounds<br />
containing nitrogen or phosphorus down to the picogram<br />
level. The NPD has become the detector of choice for<br />
low-level drug and pesticide applications because of its<br />
sensitivity and selectivity.<br />
Kit includes detector, heater, sensor, heater block, air<br />
needle valve, and hydrogen pressure regulator with snubber<br />
and two beads. Requires but does not include amplifier. For<br />
AutoSystem GC Firmware revision 1.4 or greater is required.<br />
Firmware must be PerkinElmer Service installed.<br />
Voltage Part No. Each (€)<br />
120 V AutoSystem N6120090<br />
240 V AutoSystem N6120091 5300<br />
120 V Clarus N6520024<br />
230 V Clarus N6520025 1730<br />
NPD Amplifier<br />
Required for use with<br />
NPD Add-On Kit.<br />
NPD with PPC Add-On Kit<br />
Kit includes detector, heater, sensor, heater block, and<br />
programmable pneumatic control for detector combustion<br />
gases and two beads. Requires but does not include amplifier<br />
(N6120094). The AutoSystem XL or Clarus GC must be PPC<br />
ready. If not, the PPC upgrade kit (N6120146) is required.<br />
(See page 166 for more information.) Installation by<br />
PerkinElmer Service is required, but not included.<br />
Voltage Part No. Each (€)<br />
120 V N6120126<br />
240 V N6120127 3045<br />
Column Adapter<br />
1/4 in. Packed Column Adapter<br />
1/8 to 1/4 in. detector receiver adapter<br />
for use with 1/4 in. packed columns.<br />
Two included (injector/detector).<br />
Part No.<br />
Part No.<br />
Each (€)<br />
N6120094 400<br />
Each (€)<br />
00080100 172<br />
1<br />
2<br />
3<br />
4<br />
Collector Head N6100253 574<br />
Bead Assembly (pkg. 5) N6120093 689<br />
Single pkg. N6120092 185<br />
Jet Assembly N6100038 147<br />
NPD Body N6100228 504<br />
Air in<br />
Hydrogen in<br />
1<br />
Column Connection<br />
2<br />
3<br />
4<br />
Detectors Gas Chromatography<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
139
Detectors<br />
Photoionization Detector (PID)<br />
Gas Chromatography Detectors<br />
Add-On Kits<br />
PID Add-On Kit (Manual Pneumatics)<br />
The PID utilizes a high-intensity ultraviolet light source to<br />
ionize the sample components eluting from the column in<br />
order to generate the chromatographic signal. The PID has<br />
a maximum recommended operating temperature of 250 °C.<br />
The lamp can be replaced with a blanking disk to allow<br />
bake-out operation (up to 350 °C).<br />
Kit includes detector, heater, sensor, makeup gas needle<br />
valve, and all necessary mounting hardware for installation<br />
on an AutoSystem GC. Requires but does not include<br />
amplifier (N6120061) and lamp power supply (N6120062).<br />
Firmware revision 1.2 or greater is required. Firmware must<br />
be PerkinElmer Service installed. AutoSystem operator’s<br />
manual (09908559) is required if not revision ƒ or higher.<br />
Voltage Part No. Each (€)<br />
120 V AutoSystem N6120047<br />
240 V AutoSystem N6120057 8900<br />
120 V Clarus N6520026<br />
230 V Clarus N6520027 7300<br />
PID Amplifier<br />
Required for use with<br />
PID Add-On Kit.<br />
PID Lamp Power Supply<br />
Required for use with<br />
PID Add-On Kit.<br />
PID with PPC Add-On Kit<br />
Part No.<br />
Each (€)<br />
N6120061 396<br />
Part No.<br />
Each (€)<br />
N6120062 398<br />
Kit includes detector, heater, sensor, heater block, and<br />
programmable pneumatic control for makeup gas. Requires<br />
but does not include amplifier (N6120061) and power<br />
supply (N6120062). The GC must be PPC ready. If not, a<br />
PPC upgrade kit (N6120146) is required. (See page 166 for<br />
more information.) Installation by PerkinElmer Service is<br />
required, but not included.<br />
Voltage Part No. Each (€)<br />
120 V N6120130<br />
230 V N6120131 12900<br />
Detector Series Operation Kits<br />
Description Part No. Each (€)<br />
PID/FID, PID/ECD N6120059 293<br />
Series kit for directing effluent<br />
from a PID to an FID or an ECD<br />
Miscellaneous Accessories<br />
Description Part No. Each (€)<br />
Bakeout Disk 03302989 62<br />
Lamp Cleaning Compound 03302775 172<br />
1/4 in. Detector Receiver 03300866 261<br />
1/8 in. Detector Receiver 03300865 261<br />
Replacement Lamps and Parts<br />
1<br />
2<br />
3<br />
4<br />
5<br />
6<br />
7<br />
8<br />
Description Part No. Each (€)<br />
PID Lamp (10.2eV), For most applications 03303599 721<br />
including aromatics, alkenes, and aliphatics<br />
higher than C4. Shipped standard with PID<br />
PID Lamp (9.5eV), Improved selectivity for 03303598 593<br />
multiple ring aromatic, sulfur compounds<br />
PID Lamp Window Seal 03302778 47<br />
PID Lower Lamp Seal 03302777 79<br />
Shoulder Pin 03302976 110<br />
Cap Nut 03303773 46<br />
Base Assembly 03302979 2753<br />
Spring 03302973 13<br />
Cap with Harness<br />
N6101696<br />
5<br />
8<br />
7<br />
4<br />
1<br />
2<br />
3<br />
6<br />
140
Detectors<br />
Thermal Conductivity Detector (TCD)<br />
Add-On Kits<br />
■<br />
■<br />
■<br />
■<br />
Lower Internal Volume and Smaller Overall Size<br />
No Makeup Gas Required with 0.53 mm and 0.32 mm i.d.<br />
Capillary Columns<br />
Series Connection Option<br />
Excellent Sensitivity Over a Wide Dynamic Range<br />
TCD Add-On Kit (Manual Pneumatics)<br />
Kit includes all necessary items to install the TCD into the<br />
instrument: detector, heater, sensor, heater block, 1/16 in.<br />
gas line, and flow controller pneumatics. Requires, but does<br />
not include, amplifier (N6120015). The TCD can only be<br />
installed in the rear detector position.<br />
Voltage Part No. Each (€)<br />
120 V AutoSystem N6120012<br />
240 V AutoSystem N6120027 4260<br />
120 V Clarus N6520022<br />
230 V Clarus N6520023 2400<br />
TCD Amplifier<br />
TCD with PPC Add-On Kit<br />
Kit includes detector, heater, sensor, heater block, and<br />
programmable pneumatic control for reference gas. Requires<br />
but does not include amplifier (N6120015). The TCD can<br />
only be installed in the rear detector position. The GC must<br />
be PPC ready. If not, a PPC upgrade kit (N6120146) is<br />
required. (See page 166 for more information.) Installation<br />
by PerkinElmer Service is required, but not included.<br />
Voltage Part No. Each (€)<br />
120 V N6120124<br />
230 V N6120125 2827<br />
TCD with PPC Makeup Gas Kit<br />
Includes parts required to add PPC controlled makeup<br />
gas to an existing TCD. Includes tubing, tee-piece, PPC<br />
pneumatics module, and PPC frit #4<br />
(N6120155). Requires PPC capability<br />
in the GC.<br />
Part No.<br />
N6120150<br />
Each (€)<br />
1441<br />
Column Adapters<br />
Part No.<br />
Each (€)<br />
N6120015 610<br />
Description Part No. Each (€)<br />
1/8 to 1/4 in. 00080100 172<br />
Column adapter for use with 1/4 in.<br />
packed columns<br />
1/8 to 1/16 in. N6120020 69<br />
Column adapter for use with capillary columns<br />
Thermal Conductivity Detector<br />
TCD/FID Series Operation Kit<br />
TCD and FID series operation kit for<br />
directing effluent from a TCD to an FID.<br />
Part No.<br />
Each (€)<br />
N6120006 166<br />
TCD Detector Makeup Gas Kit (Manual Pneumatics)<br />
For use with TCD (at low flow rates). Required when using<br />
0.25 mm i.d. and recommended when using 0.32 mm i.d.<br />
capillary columns. Kit includes 1 m of 1/16 in. tubing to<br />
connect to gas supply, graphite/vespel<br />
ferrules, manual pneumatics,<br />
and installation instructions.<br />
Part No.<br />
N6120080<br />
Each (€)<br />
510<br />
Detectors Gas Chromatography<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
141
Headspace Accessories and Supplies<br />
Headspace <strong>Instruments</strong><br />
PerkinElmer TurboMatrix<br />
Headspace Samplers<br />
PerkinElmer TurboMatrix Headspace Samplers eliminate tedious and error-producing steps required<br />
in other GC sample preparation techniques, enabling you to analyze volatile compounds in less time.<br />
The intuitive touch-screen graphical user interface provides easy control of the sampler.<br />
TurboMatrix 16<br />
TurboMatrix 40<br />
TurboMatrix<br />
Headspace Trap<br />
The TurboMatrix Headspace (HS)<br />
system is fully self-contained and<br />
can be interfaced to almost any gas<br />
chromatograph, giving you access to<br />
PerkinElmer’s proven headspace<br />
technology, regardless of the brand or<br />
model GC you have in your laboratory.<br />
The TurboMatrix system maximizes<br />
sample throughput. The system can<br />
simultaneously thermostat up to 12<br />
samples, ensuring that the next sample<br />
is always ready for analysis upon<br />
completion of the previous run. This<br />
adds up to a significant time saving since<br />
there is no need to wait for the next<br />
sample to heat.<br />
Volatile compounds in almost any<br />
sample matrix can be analyzed simply<br />
and quickly by headspace gas<br />
chromatography. Only PerkinElmer<br />
headspace samplers utilize a pneumaticpressure-balanced<br />
system, a proven<br />
technology that’s been used in all<br />
PerkinElmer headspace samplers for<br />
more than 35 years. This unique,<br />
patented technique provides higher<br />
sensitivity and better performance<br />
than alternative techniques.<br />
The pressure-balanced sampling technique:<br />
■<br />
■<br />
■<br />
■<br />
■<br />
Produces sharper peaks by rapidly transferring<br />
a narrow sample band to the GC column.<br />
Increases sensitivity since there is no carrier gas<br />
dilution of sample.<br />
Avoids fractionation due to pressure changes<br />
in the syringe.<br />
Eliminates multiport valves that are prone to<br />
adsorption and may introduce dead volumes.<br />
Provides exceptional reproducibility equal to that<br />
obtainable with liquid.<br />
The TurboMatrix system is available<br />
in your choice of entry-level, mid-range,<br />
or high-capacity systems. And, since<br />
upgradeability is built in, you can adapt<br />
your system to changing requirements<br />
by upgrading from one model to the<br />
next or adding accessories that provide<br />
more capabilities.<br />
142
Headspce Add-On Kits<br />
Cryofocusing Add-On Kit, TurboMatrix HS<br />
Adds cryofocusing capability to a TurboMatrix 40 or<br />
TurboMatrix 110 headspace sampler. Includes water trap<br />
to remove the water from headspace samples taken from<br />
aqueous solutions. Note: Requires but does not include,<br />
LN2 Dewar (B0500924). Also requires, but does not include,<br />
an options board to be installed in the TurboMatrix 40<br />
headspace sampler. Installation<br />
by PerkinElmer Service is required, Part No. Each (€)<br />
but not included.<br />
M0413550 3941<br />
HS 40XL Cryofocusing Accessory (White Color)<br />
Consists of cryofocusing module, firmware, required tubing<br />
unions, and water trap to be installed in AutoSystem GC.<br />
Requires liquid nitrogen storage tank.<br />
Installation by PerkinElmer Service<br />
is required, but not included.<br />
Part No.<br />
N1010047<br />
Each (€)<br />
2716<br />
Replacement Water Trap<br />
for Cryofocusing Accessory<br />
Options Board/BCD Output Board, TurboMatrix HS<br />
Required for installation of the following options on<br />
the TurboMatrix 40 headspace sampler – Vial Shaker<br />
and Cryofocusing – and when upgrading a TurboMatrix<br />
16 or 40 headspace sampler to a TurboMatrix 110. Also<br />
provides output of BCD information regarding tube position<br />
numbers and six relays for timed control of external<br />
devices. Installation by PerkinElmer Service is required, but<br />
not included. (Fitted as standard<br />
on TurboMatrix 110 HS).<br />
Part No. Each (€)<br />
HS 40 Options Board<br />
Allows up to six optional control ICs.<br />
Installation by PerkinElmer Service<br />
is required, but not included.<br />
TurboMatrix Headspace PPC Add-On Kit<br />
Includes parts to convert a headspace sampler from manual<br />
pneumatics to electronic Programmable Pneumatic Control<br />
(PPC). Installation by PerkinElmer<br />
Service is required, but not included. Part No. Each (€)<br />
Headspace Accessories and Supplies<br />
Part No.<br />
Each (€)<br />
B4000057 402<br />
M0413551 988<br />
Part No.<br />
Each (€)<br />
B0184142 261<br />
M0413548 3418<br />
Vial Shaker Add-On Kit,<br />
Headspace and Headspace Trap<br />
HS 40XL Shaker Accessory Add-On Kit<br />
Add-On Kits<br />
Adds a Frequency Scanning Shaker to a TurboMatrix 40<br />
or TurboMatrix 110 headspace sampler. Note: Requires,<br />
but does not include, an options board to be installed in<br />
the TurboMatrix 40 headspace sampler. Installation by<br />
PerkinElmer Service is required,<br />
but not included.<br />
Part No. Each (€)<br />
M0413549 1314<br />
Adds Frequency Scanning Shaker to vibrate all samples in<br />
thermostatting chamber. Installation by PerkinElmer Service<br />
is required, but not included.<br />
Color Part No. Each (€)<br />
Blue N1010050 4336<br />
Red B0505475 3941<br />
Headspace Accessories and Supplies Gas Chromatography<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
143
Gas Chromatography Headspace Accessories and Supplies<br />
Headspace Accessories and Supplies<br />
Headspace Accessories<br />
Miscellaneous Accessories<br />
TurboMatrix HS Standard Length<br />
Heated Transfer Line (960 mm)<br />
For operation up to 210 °C.<br />
TurboMatrix HS/HS Trap Long<br />
Heated Transfer Line (1650 mm)<br />
For operation up to 210 °C.<br />
Fused–Silica Capillary Transfer Line<br />
Tube i.d. (mm) Length (m) Part No. Each (€)<br />
0.25 5 N9301356 37<br />
0.32 5 N9301357 37<br />
Siltek Deactivated Fused Silica Transfer Line<br />
Tube i.d. (mm) Length (m) Part No. Each (€)<br />
0.25 5 N9316607 70<br />
0.32 5 N9316608 77<br />
Zero Dilution Inner Liner<br />
To be used with zero dilution outer liner. The powerful<br />
zero dilution liner combination allows you to achieve lower<br />
detection limits, sharpen peak shape, and increase throughput<br />
for many routine analyses. Installed in an AutoSystem Series<br />
or Clarus GC standard capillary or PSS injector, this optional<br />
special hourglass insert connects the fused-silica transfer<br />
line from the headspace sampler to the capillary column,<br />
permitting undiluted and efficient sample transfer. The<br />
insert provides the advantages of a<br />
direct connection, while maintaining Part No. Each (€)<br />
the capability to perform split injections.<br />
N1011446 41<br />
Zero Dilution Capillary Injector Outer Liner<br />
To be used with zero dilution inner liner. The powerful<br />
zero dilution liner combination allows you to achieve lower<br />
detection limits, sharpen peak shape, and increase throughput<br />
for many routine analyses. Installed in an AutoSystem Series<br />
or Clarus GC standard capillary injector, this optional special<br />
hourglass insert connects the fused-silica transfer line from<br />
the headspace sampler to the capillary column, permitting<br />
undiluted and efficient sample transfer. The insert provides<br />
the advantages of a direct connection,<br />
while maintaining the convenience of Part No. Each (€)<br />
using a split injector as an interface.<br />
N1011445 74<br />
Zero Dilution PSS<br />
Injector Outer Liner<br />
Part No.<br />
Gas Chromatography – Theory and Practice,<br />
Static Headspace Book by L. Ettre and B. Kolb<br />
Each (€)<br />
M0413643 1314<br />
Part No.<br />
Each (€)<br />
M0413552 2168<br />
Part No.<br />
Part No.<br />
Each (€)<br />
N1011447 90<br />
Each (€)<br />
N1011210 153<br />
TurboMatrix HS Trap Cold Trap Tube (Carbotrap C)<br />
Standard cold trap (M0410094)<br />
packed with Carbopack C.<br />
O-Ring<br />
7 mm<br />
TurboMatrix Headspace<br />
Sampler User’s Manual<br />
Cool Platen<br />
For storage of vials below ambient down to +5 °C. Contains<br />
cool platen and tubing. Requires a thermostatted external<br />
cooling circulation water bath. Installation by PerkinElmer<br />
Service is required, but not included.<br />
Note: Requires, but does not include,<br />
Cryostat Liquid Immersion Cooler.<br />
Part No.<br />
B0500778<br />
Each (€)<br />
2270<br />
Extended Transfer Line (1650 mm HS 40/40XL)<br />
Extra-long transfer line to allow installation of HS 40XL on<br />
the right side of the AutoSystem Series/Clarus GC or to any<br />
gas chromatograph where the HS 40XL<br />
is situated at an extended distance. Part No. Each (€)<br />
High Pressure Sampling Accessory<br />
Used for operation with capillary columns requiring a<br />
low head pressure. Also used for carrier gas flow control.<br />
Accessory includes high-pressure sampling module with<br />
pressure regulator, gauge, firmware, tubing, and unions.<br />
Installation by PerkinElmer Service<br />
is required, but not included.<br />
Part No. Each (€)<br />
Note: Requires, but does not include, Options Board.<br />
HS 40XL to AutoSystem Series<br />
Left Side Mounting Kit (White Color)<br />
For connecting the HS 40XL transfer line through the left<br />
side of the AutoSystem XL GC directly to the column in the<br />
oven instead of via the injection port. Includes a new GC<br />
side panel and parts for attaching the transfer line to the<br />
GC. Requires, but does not include, some type of zero dead<br />
volume connector to connect to the column (for example,<br />
a universal capillary column connector,<br />
N9302149). Installation by PerkinElmer Part No. Each (€)<br />
Service is recommended.<br />
N1010048 510<br />
HS 40XL Instruction Manual<br />
Part No.<br />
Each (€)<br />
N6200150 317<br />
Part No.<br />
Each (€)<br />
09200091 30<br />
Part No.<br />
Each (€)<br />
M0413401 93<br />
B4000046 2168<br />
B0505271 3278<br />
Part No.<br />
Each (€)<br />
09935404 73<br />
144
Internal Carrier Gas Pressure Control<br />
For carrier gas control. Includes regulator, gauge, tubing, and<br />
unions. Installation by PerkinElmer<br />
Service is required, but not included. Part No. Each (€)<br />
Recycle Mode Accessory<br />
Continuously repeats sequence with setup method. Installation<br />
by PerkinElmer Service is required, but not included.<br />
Note: Requires, but does not include, Options Board.<br />
Remote Control Software (RCS)<br />
HS 40XL Control Software<br />
Windows ® -based, flexible, easy-to-use external control software<br />
for the HS 40 and HS 40XL. The user can develop and store<br />
methods and sequences. Run reports can be obtained, stored,<br />
and printed. On-screen, context sensitive help available. Can<br />
be operated in combination with PerkinElmer TotalChrom TM<br />
Software. Requires RS-232<br />
Interface for the HS 40XL.<br />
Part No. Each (€)<br />
TurboMatrix HS PC (RCS) v1.1 for WIN NT<br />
NOTE: This software version is only supported under Windows ® NT4.0 Service<br />
Pack 6a. Windows 2000 users should order Version 1.2 (see Part Number<br />
N6200200 below). This software requires the HS unit to have firmware<br />
version 1.87 or earlier. Provides full external control of a TurboMatrix<br />
headspace sampler from a personal computer running under Windows 95, 98<br />
or NT. Methods and sequences can be generated, stored, edited, printed and<br />
executed. Functions include setup, diagnostics, user<br />
defined access levels and run reports. On-screen Part No. Each (€)<br />
interactive help function is available. Cable included.<br />
M0413348 822<br />
TurboMatrix HS PC (RCS) v1.2 for WIN 2000<br />
NOTE: This software requires the HS unit to have firmware version 1.87 or<br />
earlier. Provides full external control of a TurboMatrix headspace sampler<br />
from a personal computer running under Windows 2000 SP2. Methods and<br />
sequences can be generated, stored, edited, printed and executed. Functions<br />
include setup, diagnostics, user defined access<br />
levels and run reports. On-screen interactive help<br />
function is available. Cable included.<br />
Part No.<br />
N6200200<br />
Each (€)<br />
819<br />
Headspace Accessories and Supplies<br />
B0505268 1314<br />
Part No.<br />
Each (€)<br />
B0197336 606<br />
B0510984 844<br />
TurboMatrix HS Trap PC (RCS) v2.0<br />
Headspace Accessories<br />
NOTE: This software requires the HS unit to have firmware version 2.00.<br />
Provides full external control of a TurboMatrix headspace sampler from a<br />
personal computer running under Windows XP SP1 or Windows 2000 SP3.<br />
Methods and sequences can be generated, stored, edited, printed and executed.<br />
Functions include setup, diagnostics, user defined access levels and run<br />
reports. Includes control of the TurboMatrix Trap if present on the HS unit. Onscreen<br />
interactive help function is available. Cable included. RCS version 2.0<br />
is available for those who do not wish to update from TotalChrom (TC) 6.2.1<br />
and/or for those who need to use a TurboMatrix<br />
HS unit with revision 2.0 or lower firmware.<br />
Part No. Each (€)<br />
Sample Trays<br />
TurboMatrix 40 Mid-Range Sample Tray<br />
40-position sample tray for use on<br />
the mid-range headspace sampler.<br />
TurboMatrix 110 High-Capacity Sample Tray<br />
110-position sample tray for use on<br />
the high-capacity headspace sampler.<br />
Tools<br />
O-Ring Removal Tool<br />
For replacing O-Rings in upper<br />
and lower seal assemblies.<br />
Headspace Vial Gauge<br />
Used to check 20 mL headspace<br />
vials for correct dimensions.<br />
Adapter Sleeve Torsion Bar<br />
For loosening upper seal.<br />
Thumbscrew Removal Tool<br />
For removing lower seal assembly.<br />
Spigot Key<br />
For loosening lower seal.<br />
Open End Wrench, 1/4 - 5/16 in.<br />
For use in mounting the Transfer Line.<br />
N6700200 745<br />
Part No.<br />
Part No.<br />
Each (€)<br />
B0147449 20<br />
Part No.<br />
Each (€)<br />
B0151737 102<br />
Part No.<br />
Each (€)<br />
B0135485 26<br />
Part No.<br />
Each (€)<br />
B0131410 20<br />
Part No.<br />
Each (€)<br />
B0500843 39<br />
Part No.<br />
Each (€)<br />
M0413592 112<br />
Part No.<br />
Each (€)<br />
M0413593 332<br />
Each (€)<br />
09907233 23<br />
Headspace Accessories and Supplies Gas Chromatography<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
145
Gas Chromatography Headspace Accessories and Supplies<br />
Headspace Accessories and Supplies<br />
Headspace Accessories<br />
Open End Wrench, Sw-7<br />
Transfer Line End Cap<br />
PE Injector Transfer Line Adapter<br />
TurboMatrix and HS 40XL<br />
Adapter Kits for Non-PerkinElmer<br />
Gas Chromatographs<br />
All kits include a Modified Septum Nut Adapter and the instructions for<br />
physical installation and interfacing of the two instruments. Use the standard<br />
PerkinElmer cables (N1011206, 2 needed) for ready/run connections.<br />
Headspace Adapter Kit for Carlo Erba<br />
For connecting a TurboMatrix or HS 40<br />
(XL) headspace sampler to a Carlo Erba<br />
Mega or Vega gas chromatograph.<br />
Headspace Adapter Kit for Fisons Series 8000<br />
For connecting a TurboMatrix or HS<br />
40 (XL) headspace sampler to a Fisons<br />
Series 8000 gas chromatograph.<br />
Headspace Adapter Kit for Gerstel CIS Injector<br />
For connecting a TurboMatrix or HS 40 (XL) headspace<br />
sampler to a Gerstel Cooled Injector System Inlet. As the<br />
Gerstel injector can be installed on several GC models,<br />
customer should contact the GC<br />
manufacturer for the appropriate<br />
“Remote Start/Stop Cable.”<br />
Part No.<br />
B0506539<br />
Each (€)<br />
198<br />
Headspace Adapter Kit for HP 6890,<br />
HP 6850, or HP 5890 On-Column<br />
Part No.<br />
Part No.<br />
Each (€)<br />
B0506603 147<br />
Part No.<br />
Each (€)<br />
B0510251 10<br />
Part No.<br />
Each (€)<br />
B0510403 53<br />
Part No.<br />
Each (€)<br />
B0505266 186<br />
Each (€)<br />
B4000012 140<br />
For connecting a TurboMatrix or HS 40 (XL) headspace<br />
sampler to an on-column injector of an HP 6890, HP 6850,<br />
HP 5890, or HP 5890 Series 2 gas chromatograph.<br />
Note: Installation on HP 6890 and HP 6850 requires a TurboMatrix/HS 40 (XL)<br />
to HP 6890/6850 GC Ready/Start Cable (N610-0410). For installation on<br />
HP 5890, customer should contact Hewlett-Packard<br />
for the appropriate “Remote Start/Stop Cable.” Part No. Each (€)<br />
B0507944 140<br />
Headspace Adapter Kit for Shimadzu<br />
For connecting a TurboMatrix or HS 40 (XL) headspace<br />
sampler to the following Shimadzu gas chromatographs:<br />
GC 9a for capillary columns, 14A<br />
packed columns, 14B packed columns,<br />
17A packed, and capillary columns.<br />
Part No.<br />
B0505889<br />
Each (€)<br />
140<br />
Headspace Adapter Kit for Shimadzu GC14A/B<br />
For connecting a TurboMatrix or HS 40 (XL) headspace<br />
sampler to a Shimadzu GC 14A/14B gas<br />
chromatograph with capillary columns. Part No. Each (€)<br />
Headspace Adapter Kit for Shimadzu GC16<br />
For connecting a TurboMatrix or<br />
HS 40 (XL) headspace sampler to a<br />
Shimadzu GC 16 gas chromatograph.<br />
Headspace Adapter Kit for Thermo Trace GC<br />
For connecting a TurboMatrix or<br />
HS 40(XL) headspace sampler to a<br />
Thermo Trace gas chromatograph.<br />
Headspace Adapter Kit<br />
for Varian Capillary Column Injector<br />
For connecting a TurboMatrix or HS 40(XL) headspace<br />
sampler to a Varian 3400 or 3800 gas chromatograph<br />
capillary column injector. Customer<br />
should contact Varian for the<br />
appropriate “Remote Start/Stop Cable.”<br />
Part No.<br />
N6201001<br />
Each (€)<br />
168<br />
Headspace Adapter Kit<br />
for Varian Packed Column Injector<br />
For connecting a TurboMatrix or HS 40(XL) headspace<br />
sampler to a Varian 3400 or 3800 gas chromatograph<br />
packed column injector. Customer<br />
should contact Varian for the<br />
appropriate “Remote Start/Stop Cable.”<br />
Part No.<br />
B0505978<br />
Each (€)<br />
140<br />
Headspace Adapter Kit for Varian/Finnigan ITS40<br />
For connecting a TurboMatrix or<br />
HS 40(XL) headspace sampler to a<br />
Varian/Finnigan ITS40 GC/MS System.<br />
Installation Instructions: Headspace to<br />
Non-PerkinElmer Gas Chromatographs<br />
B4000033 147<br />
Part No.<br />
Each (€)<br />
B0508521 147<br />
Part No.<br />
Each (€)<br />
N6201030 143<br />
Part No.<br />
Each (€)<br />
B0507942 217<br />
Instructions for physical installation and interfacing<br />
of the TurboMatrix or HS 40(XL) headspace sampler<br />
to non-PerkinElmer GCs.<br />
Note: This kit is intended for GC’s not listed above.<br />
Part No. Each (€)<br />
B0508738 77<br />
146
TurboMatrix Headspace to HP 6890<br />
GC Ready Start Cable<br />
Connects a TurboMatrix Headspace Sampler to an<br />
HP 6890 or HP 6850 GC.<br />
Note: Customer should contact gas chromatograph manufacturer for the<br />
appropriate “Remote Start/Stop Cable.”<br />
Part No. Each (€)<br />
Start/Ready Cables<br />
Description Part No. Each (€)<br />
HS 40XL to Agilent 6890 GC N6100410 149<br />
For all PerkinElmer GCs and HP 5890 (2 needed) N1011206 35<br />
TurboMatrix Headspace/HS 40/<br />
HS 40XL Replacement Parts<br />
and Needle Identification<br />
Needle Identification<br />
The number of rings engraved into the needle top<br />
in various types of needles.<br />
Number of Rings Number of Rings<br />
Needle Type for Stainless Steel for Platinum Iridium<br />
Wide-Bore none 1<br />
Small-Bore none 2<br />
Jet 3 4<br />
Replacement Parts<br />
1<br />
2<br />
3<br />
4<br />
5<br />
6<br />
7<br />
8<br />
9<br />
Headspace Accessories and Supplies<br />
N6100410 149<br />
Description Part No. Each (€)<br />
Platinum/Iridium Needle, Wide-Bore B0144169 2371<br />
Platinum/Iridium Needle, Small-Bore B0500959 2032<br />
Platinum/Iridium Needle, Jet B0510364 1084<br />
Silcosteel Needle, for Headspace Trap Only N6700130 994<br />
Stainless Steel Needle, Wide-Bore B0131385 268<br />
Stainless Steel Needle, Small-Bore B0500987 1024<br />
Stainless Steel Needle, Jet (ships with instrument) B4000011 547<br />
Needle Seal Assembly (without O-Rings) B0500833 74<br />
O-Ring for Needle Seal Assembly (pkg. 10) B0198110 42<br />
Vespel Ferrule 1⁄16 in. (pkg. 10) 09920127 84<br />
Male Nut 1⁄16 in. N9302832 5<br />
GLT Adapter Tube B0503956 207<br />
GLT Adapter Tube, Silcosteel N6700113 529<br />
Graphite/Vespel Ferrule 1⁄16 in. x 0.4 mm 09920104 84<br />
(for use with 0.25 mm i.d. transfer line, pkg. 10)<br />
Graphite/Vespel Ferrule 1⁄16 in. x 0.5 mm 09903700 48<br />
(for use with 0.32 mm i.d. transfer line, pkg. 10)<br />
Nut 1⁄ 16 in. Swagelok N9300059 54<br />
Fused-Silica Capillary Transfer Line:<br />
0.25 mm i.d. x 5 m length N9301356 37<br />
0.32 mm i.d. x 5 m length N9301357 37<br />
TurboMatrix Upgrade Kits<br />
Headspace Accessories<br />
TurboMatrix 16 to 40 Upgrade Kit (Headspace Only)<br />
Includes parts to upgrade an entry-level headspace sampler<br />
to a mid-range headspace sampler that can perform automated<br />
analysis of up to 40 vials with overlapping themostatting of<br />
up to 12 vials. Installation by<br />
PerkinElmer Service is required,<br />
but not included.<br />
Part No.<br />
M0413545<br />
Each (€)<br />
5300<br />
TurboMatrix 16 to 110 Upgrade Kit (Headspace Only)<br />
Includes parts to upgrade an entry-level headspace sampler<br />
to a high-capacity headspace sampler that can perform<br />
automated analysis of up to 110 vials with overlapping<br />
themostatting of up to 12 vials.<br />
Installation by PerkinElmer Service<br />
is required, but not included.<br />
Part No.<br />
M0413546<br />
Each (€)<br />
18400<br />
TurboMatrix 40 to 110 Upgrade Kit<br />
(Headspace and Headspace Trap)<br />
Includes parts to upgrade a mid-range headspace sampler<br />
to a high-capacity headspace sampler that can perform<br />
automated analysis of up to 1100 vials with overlapping<br />
themostatting of up to 12 vials.<br />
Installation by PerkinElmer Service<br />
is required, but not included.<br />
Part No.<br />
M0413547<br />
Each (€)<br />
15100<br />
Note: Requires, but does not include, an options board (M0413551) to be installed<br />
in the headspace sampler. Installation by PerkinElmer Service is required,<br />
but not included.<br />
9<br />
8<br />
7<br />
6 5<br />
4<br />
1<br />
2<br />
3<br />
2<br />
3<br />
Headspace Accessories and Supplies Gas Chromatography<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
147
Gas Chromatography Headspace Accessories and Supplies<br />
Headspace Accessories and Supplies<br />
Headspace Vials, Caps, and Septa<br />
Headspace Caps and Septa<br />
Patented safety springs and caps designed to<br />
release at vial headspace pressures above 73 psi.<br />
Aluminum-Coated Silicone<br />
Rubber Headspace Septa<br />
Includes caps and starsprings<br />
(19 mm diameter). Maximum<br />
temp. 120 °C.<br />
Description Part No. Each (€)<br />
pkg. 100 B0104243 101<br />
pkg. 1000 B0104244 906<br />
pkg. 1000 (preassembled) B4000028 952<br />
Butyl Rubber Headspace Septa<br />
Includes caps and starsprings<br />
(19 mm diameter). Maximum<br />
temp. 100 °C.<br />
Description Part No. Each (€)<br />
pkg. 100 B0159356 51<br />
pkg. 1000 B0159357 460<br />
pkg. 1000 (preassembled) N1010070 507<br />
PTFE-Coated Butyl Rubber<br />
Headspace Septa<br />
Includes caps and starsprings<br />
(19 mm diameter). Maximum<br />
temp. 100 °C.<br />
Description Part No. Each (€)<br />
pkg. 100 B0104239 68<br />
pkg. 1000 B0104240 614<br />
pkg. 1000 (preassembled) B4000025 645<br />
PTFE-Coated Silicone Rubber<br />
Headspace Septa<br />
Includes caps and starsprings<br />
(19 mm diameter). Maximum<br />
temp. 210 °C.<br />
Description Part No. Each (€)<br />
pkg. 100 B0104241 86<br />
pkg. 1000 B0104242 772<br />
pkg. 1000 (preassembled) B4000022 810<br />
Headspace Septa Recommended<br />
Temperature Chart<br />
Upper Temperature<br />
Material Limit at Vial Inertness<br />
Butyl Rubber 100 °C Poor<br />
PTFE-Coated Butyl Rubber 100 °C Good<br />
Aluminum-Coated Silicone 120 to 210 °C Good<br />
PTFE-Coated Silicone 210 °C Good<br />
Headspace Vials<br />
Headspace Starter Kit<br />
Consisting of 1000 vials (B0104236), two sets of septa,<br />
each with aluminum caps and starsprings: 200 PTFE-coated<br />
butyl rubber septa (B0104239), 200 PTFE-coated silicon<br />
rubber septa (B0104241). Also included are: hand crimper<br />
(N9302785), pressure gauge with needle for vials<br />
(B0501377), two needle seal assemblies (B0500833),<br />
10 O-Rings (B0198110), and a book by B. Kolb and L.S.<br />
Ettre, Static Headspace Gas Chromatography Theory and<br />
Practice (N1011210).<br />
Part No. Each (€)<br />
Headspace Safety Sample Vials<br />
B0505601 1339<br />
Description Part No. Each (€)<br />
pkg. 1000 B0104236 370<br />
148
Vial Crimping Tools<br />
Benchtop Crimper<br />
The PerkinElmer Benchtop Crimper with interchangeable<br />
jaws provides a fast and consistent crimp on each vial, every<br />
time. Once crimping pressure is set, the lever action will<br />
repeatedly afford the user a perfectly crimped vial, with little<br />
effort. Jaws and decrimping jaws are available for 11 mm<br />
and 20 mm crimp caps.<br />
Description Part No. Each (€)<br />
Benchtop Crimper with 20 mm Jaw N6620065 1685<br />
Benchtop Crimper without Jaws N6621006 1685<br />
Jaws for Benchtop Crimper, 11 mm N6621008 391<br />
Jaws for Benchtop Crimper, 20 mm N6621009 344<br />
Headspace Accessories and Supplies<br />
Headspace Vials, Caps, and Septa<br />
Electronic Crimpers<br />
New from PerkinElmer, the 20 mm electronic crimpers<br />
and decappers are easy to use and fully rechargeable.<br />
Ergonomically designed to alleviate the potential for Carpal<br />
Tunnel Syndrome and provide a consistent crimp pressure<br />
numerous times. The electronic crimper is provided with<br />
a standard Black and Decker VeraPak ® Gold battery and<br />
charging unit. This hand-held device will crimp several<br />
hundred vials from one charge. Crimping pressure is fully<br />
adjustable for precision control. Also available in 11 mm.<br />
See page 90.<br />
Features and Benefits:<br />
■ Precision control crimping<br />
■ Ergonomically designed grip<br />
■ Numerous reproducible crimps from a single charge<br />
■ Includes standard Black and Decker VersaPak Gold<br />
battery and charger<br />
Description Part No. Each (€)<br />
20 mm Electronic Hand Crimper, 120 V N9302571<br />
20 mm Electronic Hand Crimper, 200 V N9302572 700<br />
20 mm Electronic Hand Crimper, 230 V N9302573 700<br />
20 mm Electronic Hand Crimper, 240 V N9302574 700<br />
20 mm Electronic Hand Decapper, 120 V N9302579<br />
20 mm Electronic Hand Decapper, 200 V N9302580 700<br />
20 mm Electronic Hand Decapper, 230 V N9302581 700<br />
20 mm Electronic Hand Decapper, 240 V N9302585 700<br />
Electronic Crimper Battery N9302582 44<br />
Hand Crimpers<br />
Hand Crimper<br />
Part No. N9302571<br />
Description Part No. Each (€)<br />
Hand Held Crimper, 20 mm N9302785 256<br />
Hand Held Decapper, 20 mm N9301270 64<br />
Headspace Accessories and Supplies Gas Chromatography<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
149
Injectors<br />
Capillary Injectors<br />
Injector Replacement Parts<br />
Components Part No. Each (€)<br />
Gas Chromatography Injectors<br />
18<br />
Manual Gas Control<br />
11<br />
17<br />
6<br />
1<br />
2<br />
3<br />
4<br />
6<br />
8<br />
10<br />
14<br />
15<br />
16<br />
19<br />
1<br />
2<br />
3<br />
4<br />
5<br />
6<br />
8<br />
10<br />
11<br />
12<br />
13<br />
14<br />
15<br />
16<br />
17<br />
18<br />
19<br />
Injector Cover N6101482 21<br />
Septum Cap N6100153 96<br />
Thermogreen TM Septum (pkg. 50)* N6621028 202<br />
Injector Top Nut N6101358 96<br />
Injector Head N6100158 421<br />
O-Ring, Silicone for Glass Liner (pkg. 10) N6101374 9<br />
Maximum injector temperature 250 °C,<br />
O-Ring, Graphite for Glass Liner (pkg. 5) N6101378 21<br />
Maximum injector temperature 450 °C.<br />
O-Ring, KALREZ ® for Glass Liner (pkg. 1) N9302782 37<br />
Maximum injector temperature 450 °C.<br />
O-Ring, Viton ® for Glass liner (pkg. 1) N9302783 4<br />
Maximum injector temperature 250 °C,<br />
recommended for use with Mass Spec.<br />
ships with instrument<br />
Quartz Liner (2 mm) for Splitless Operation N6121002 22<br />
Quartz Liner (4 mm) for Split Operation N6121001 34<br />
or Large Volume Splitless Injection<br />
Glass Liner (2 mm) for Splitless Operation N6101372 31<br />
Glass Liner (4 mm) for Split Operation N6101052 29<br />
Deactivated Liner for Splitless Operation N6121021 109<br />
2 mm, packed with wool. (pkg. 5)<br />
Deactivated Liner for Split Operation N6121020 236<br />
4 mm, packed with wool. (pkg. 5)<br />
Deactivated Uniliner N6121022 331<br />
4 mm, packed with wool. (pkg. 5)<br />
Injector Body N6100047 306<br />
1/8 in. Swagelok TM Nut Brass (pkg. 5) N9300056 9<br />
Restrictor N6101034 55<br />
1/8 in. Graphite/Vespel Ferrule (pkg. 10) 09920301 84<br />
1/4 in. Graphite Ferrule (pkg. 10) 09920140 43<br />
1/4 in. Swagelok Nut, Stainless Steel (pkg. 5) N9300055 30<br />
Injector Adapter N6100157 105<br />
Charcoal Trap N6100275 242<br />
Charcoal Trap for PPC Version** N6100331 553<br />
Split Vent Tube N6100159 42<br />
Column Nut 1/16 in. Long length 09903392 27<br />
for reversed ferrule (pkg. 5)<br />
* For more septa, see page 159.<br />
** Not shown.<br />
Miscellaneous Accessories<br />
Description Part No. Each (€)<br />
2 oz. Replacement Charcoal (30/60 mesh) 03300904 20<br />
5 g. Quartz Wool (Untreated) N6102354 26<br />
Column Ferrule Graphite/Vespel 09920105 84<br />
Liner Removal Tool N6100102 125<br />
Merlin Microseal Adapter Kit N9303344 434<br />
Includes: 2 Merlin Microseal septa,<br />
1 nut, and 1 injection port adapter<br />
Merlin Microseal Septa N9303345 181<br />
Zero Dilution Liner (Inner) N1011446 41<br />
Zero Dilution Liner (Outer) N1011445 74<br />
150
Injectors<br />
Capillary Injectors<br />
Split/Splitless Injector Add-On Kits<br />
Capillary Injector with PPC<br />
Kit includes split/splitless injector with programmable<br />
pneumatic control for carrier gas, split vent, heater, sensor,<br />
and heater block. The AutoSystem XL must be PPC ready.<br />
If not, a PPC upgrade kit (N6120146) is required. (See page<br />
166 for more information.) Installation by PerkinElmer<br />
Service is required, but not included.<br />
Voltage Part No. Each (€)<br />
120 V N6120138<br />
240 V N6120139 3128<br />
Complete Capillary Injector Add-On Kits<br />
Kit includes split/splitless injector in module with heater<br />
and sensor, 0-60 psig pressure regulator, and transducer for<br />
pressure readout. For manual gas control.<br />
Voltage Part No. Each (€)<br />
120 V AutoSystem N6120009<br />
240 V AutoSystem N6120022 3329<br />
120 V Clarus N6520012<br />
230 V Clarus N6520013 1916<br />
Dual Capillary Column Adapter Kit<br />
Kit includes all necessary hardware to install two capillary<br />
columns to a capillary injector. Note: Kit does not include<br />
appropriate 1/8 in. 2-hole ferrule. (See page 94) For manual<br />
gas control.<br />
Voltage Part No. Each (€)<br />
120 V N6120050 122<br />
Split/Splitless Injector Starter Kit<br />
for Manual Gas Control<br />
Includes: 2 mm i.d. quartz liner, 4 mm i.d. quartz liner,<br />
silicone O-Rings (10), Thermogreen septa (50), 0.5 mm<br />
graphite ferrules (10), 0.8 mm graphite ferrules (10), 1/16 in.<br />
stainless steel nuts (5), untreated quartz wool, packing rod,<br />
and wafer scribes (10).<br />
Part No. Each (€)<br />
N6120101 574<br />
Injectors Gas Chromatography<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
151
Injectors<br />
Packed Column Injector<br />
Add-On Kits<br />
Injector Replacement Parts<br />
Gas Chromatography Injectors<br />
Packed Column Injector Kit with Manual Pneumatics<br />
Includes: complete injector assembly with heater and sensor,<br />
0-100 mL flow controller, and column head pressure gauge<br />
for installation into the AutoSystem.<br />
Voltage Part No. Each (€)<br />
120 V* N6120007<br />
240 V* N6120023 2245<br />
Packed Column Injector Kit with PPC<br />
The kit includes complete injector assembly with<br />
programmable pneumatic control, heater, sensor, and<br />
heater block. The GC must be PPC ready. If not, a PPC<br />
upgrade kit (N6120146) is required. (See page 166 for<br />
more information.)<br />
Voltage Part No. Each (€)<br />
120 V* N6120136<br />
240 V* N6120137 2288<br />
Packed Column Injector Kit<br />
with Screen Readout and Manual Pneumatics<br />
Includes: complete injector assembly with heater and sensor,<br />
0-100 mL flow controller and column head pressure gauge,<br />
and transducer for screen readout of column carrier flow.<br />
Voltage Part No. Each (€)<br />
120 V* AutoSystem N6120008<br />
240 V* AutoSystem N6120025 2729<br />
120 V* Clarus N6520010<br />
230 V* Clarus N6520011 1398<br />
Packed Column Injector Kit AutoSystem XL and Clarus<br />
The kit includes complete injector, heater, sensor,<br />
and heater block. (Does not include pneumatics.)<br />
Voltage Part No. Each (€)<br />
120 V* N6120071<br />
240 V* N6120072 1824<br />
Packed Column Injector Starter Kit<br />
Includes glass liner, needle guide,<br />
Thermogreen septa (50), untreated<br />
quartz wool, and packing rod.<br />
Packed On-Column Injector for 1/4 in.<br />
(Long-Legged) Glass Columns<br />
Part No.<br />
Each (€)<br />
N6120100 389<br />
For use with 1/4 in. (long-legged) on-column glass column.<br />
Includes: complete injector, heater, and sensor and heater<br />
block. Does NOT include pneumatics.<br />
Voltage Part No. Each (€)<br />
120 V* N6520016<br />
240 V* N6520017 1970<br />
* Service installation required.<br />
1<br />
2<br />
3<br />
4<br />
5<br />
Description Part No. Each (€)<br />
Septum Cap N6100153 96<br />
Septa Thermogreen (pkg. 50)** N6621028 202<br />
Needle Guide N6101050 48<br />
Glass Liner N6101048 57<br />
Quartz Liner N6121000 124<br />
Packed Injector Assembly N6100048 536<br />
** For more septa see page 159.<br />
1<br />
2<br />
3<br />
4<br />
5<br />
152
Injectors<br />
Packed Column Injector<br />
Miscellaneous Accessories<br />
Injector/Detector Adapter 1/4 in.<br />
Adapter fits on injector and detector<br />
outlet (inside oven) for use with<br />
1/4 in. columns.<br />
Liner Removal Tool<br />
Allows easy removal of glass<br />
liners from injector port.<br />
Part No. Each (€)<br />
00080100 172<br />
Part No. Each (€)<br />
N6100102 125<br />
Quartz Wool<br />
Quartz wool (untreated) for<br />
packing glass liners. (5 g.)<br />
Silanized Glass Wool<br />
Packing for wide-bore glass liners.<br />
(2 oz.)<br />
Wide-Bore Adapter Kit<br />
0.53 Capillary Column Adapter Kit<br />
Part No.<br />
Each (€)<br />
N6102354 26<br />
Part No.<br />
Each (€)<br />
03300905 34<br />
Silanized Glass Wool<br />
Part No. 03300905<br />
The AutoSystem Wide-Bore Adapter Kit allows conversion<br />
of the packed inlet for 0.53 mm capillary column operation.<br />
The kit includes 0-20 mL flow control element, wide-bore<br />
adapter with 1/16 in. fitting, wide-bore glass liner, and<br />
column support hanger. Can be used in both on-column<br />
and off-column modes of operation.<br />
Part No. Each (€)<br />
N6120001 523<br />
Injectors Gas Chromatography<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
153
Injectors<br />
POC Injector<br />
POC Replacement Parts<br />
1<br />
2<br />
3<br />
4<br />
5<br />
Components Part No. Each (€)<br />
Septum Cap N6100153 96<br />
Septa (pkg. 50)** N6621028 202<br />
Needle Guide N6101702 66<br />
Liner/Hour Glass N6101703 37<br />
Body Assembly N6100256 555<br />
** For more septa see page 159.<br />
Programmed-Temperature<br />
On-Column Injector System<br />
The Programmed-Temperature On-Column (POC) Inlet is<br />
designed to be used with fused-silica capillary columns.<br />
The sample is injected onto the column while the inlet is<br />
cool.After the injection, the inlet begins to heat. This delay<br />
in heating avoids the flash vaporization associated with a<br />
normal injection. This explosive vaporization can cause<br />
thermal breakdown and/or discrimination of certain<br />
analytes, which can be avoided by using the POC.<br />
Gas Chromatography Injectors<br />
2<br />
3<br />
4<br />
1<br />
5<br />
The POC Injector is best used to achieve recovery of compounds<br />
of greater than C 60 (e.g., polywaxes). The POC utilizes flow<br />
control, producing the best recovery out to C 100 or greater.<br />
POC Injector with Manual Flow Controller<br />
and Head Pressure Gauge<br />
Kit includes all necessary hardware to install injector into<br />
AutoSystem Series or Clarus Series.<br />
Voltage Part No. Each (€)<br />
120 V* N6120076<br />
240 V* N6120077 2436<br />
POC Injector with Manual Flow Controller and Head<br />
Pressure Gauge with Flow Readout on Screen<br />
Kit includes all necessary hardware to install injector into<br />
AutoSystem Series or Clarus Series.<br />
Voltage Part No. Each (€)<br />
120 V* N6120082<br />
240 V* N6120083 3354<br />
POC Injector with PPC Add-On Kit<br />
Kit includes injector with programmable pneumatic control,<br />
heater, sensor, and heater block. The AutoSystem XL or Clarus<br />
GC must be PPC TM ready. If not, a PPC upgrade kit (N6120146)<br />
is required. (See page 166 for more information.) Installation<br />
by PerkinElmer Service is required, but not included.<br />
Voltage Part No. Each (€)<br />
120 V* N6120142<br />
240 V* N6120143 3219<br />
POC Injector Starter Kit<br />
Includes: needle guides (5), universal connectors (5),<br />
0.53 mm i.d. deactivated fused silica (5 m), 1/16 in.<br />
stainless steel nuts (5), 0.8 mm graphite ferrules (10),<br />
Thermogreen septa (50),<br />
and wafer scribes (10).<br />
Part No. Each (€)<br />
* Service installation suggested. AutoSystem firmware revision 1.7<br />
or higher. Operator’s manual (09938559) revision F or greater.<br />
N6120098 625<br />
154
Injectors<br />
PSS Injector<br />
Programmed-Temperature<br />
Split/Splitless Injector System<br />
PSS Injector Add-On Kits with Manual Pneumatics<br />
The programmed-temperature split/splitless (PSS) inlet<br />
allows accurate sample delivery to a capillary column.<br />
The PSS allows the analysis of thermally labile compounds,<br />
while eliminating the discrimination of high-boiling<br />
compounds. One of the major advantages of the PSS is<br />
that any nonvolatile material will remain in the inlet<br />
liner and not on the front of the column.<br />
PSS with pneumatics and pressure readout on screen. Kit<br />
includes all necessary hardware to install injector into GC.<br />
Voltage Part No. Each (€)<br />
120 V* AutoSystem N6120074<br />
240 V* AutoSystem N6120075 4795<br />
120 V* Clarus N6520014<br />
230 V* Clarus N6520015 2076<br />
PSS Injector with PPC<br />
Kit includes injector with programmable pneumatic control,<br />
heater, sensor, and heater block. The GC must be PPC<br />
ready. If not, a PPC upgrade kit (N6120146) is required.<br />
(See page 166 for more information.)<br />
Voltage Part No. Each (€)<br />
120 V* N6120140<br />
240 V* N6120141 3326<br />
PSS Injector Starter Kit<br />
Includes: universal connectors (5), 0.53 mm i.d. deactivated<br />
fused-silica (5 m), 2 mm i.d. quartz liner, 1 mm i.d. quartz<br />
liner, glass hourglass liner, 1/16 in. stainless steel nuts (5),<br />
0.5 mm i.d. graphite ferrules (10), 0.8 mm i.d. graphite<br />
ferrules (10), Viton ® O-Rings (6), graphite O-Rings (5),<br />
untreated quartz wool, wafer scribes<br />
(10), and Thermogreen septa (50).<br />
Part No. Each (€)<br />
Zero Dilution Liners<br />
Used together as set.<br />
N6120102 956<br />
Description Part No. Each (€)<br />
Inner Liner N1011446 41<br />
Outer Liner N1011447 90<br />
* Service installation suggested.<br />
PSS Replacement Parts<br />
1<br />
2<br />
3<br />
4<br />
5<br />
6<br />
7<br />
8<br />
9<br />
10<br />
11<br />
12<br />
13<br />
14<br />
13<br />
12<br />
Description Part No. Each (€)<br />
Septum Cap N6100153 96<br />
Injector Cover N6101482 21<br />
Septa** (pkg. 50) N6621028 202<br />
Trap, Charcoal – non PPC version N6100275 242<br />
PPC version (not shown) N6100331 553<br />
Nut N6101715 179<br />
Septum Purge N6100260 548<br />
O-Ring Viton (pkg. 10) max. temp N6101747 11<br />
250 °C, recommended for use with<br />
mass spec. Shipped with instrument.<br />
O-Ring KALREZ ® (pkg. 1) 09921004 33<br />
max. temp. 450 °C<br />
O-Ring Graphite (pkg. 5) N6101751 23<br />
max. temp. 450 °C<br />
Quartz Liner, 2 mm Split Mode N6121004 17<br />
Shipped with instrument.<br />
Quartz Liner, 1 mm Splitless Mode N6121006 108<br />
On-column liner N6101539 47<br />
Body Assembly N6100261 765<br />
Ferrule 1/8 in. x 1/16 in. (pkg. 10) 09920301 84<br />
Nut 1/8 in. 09903128 1<br />
Split Vent Line N6100159 42<br />
Purge Restrictor N6101034 55<br />
Nut 09903392 27<br />
** For more septa see page 159.<br />
11<br />
10<br />
Manual Pneumatic Control (non-PPC)<br />
1 3<br />
2<br />
4<br />
5<br />
6<br />
7<br />
8<br />
9<br />
14<br />
Injectors Gas Chromatography<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
155
Injectors<br />
PreVent<br />
Gas Chromatography Injectors<br />
Enhanced Large Volume Injection<br />
Allows the use of chlorinated solvents with<br />
an electron capture detector.<br />
PreVent Time-Saver Mode<br />
Conventional<br />
C5<br />
100 C4 C6<br />
0<br />
Analyze<br />
Cleanup<br />
Equilibrate<br />
PreVent<br />
100<br />
Analyze<br />
Cleanup<br />
Equilibrate<br />
2 μl of 20 pg/μl Pesticide Solution in n-Hexane<br />
50 μl of 20 pg/μl Solution in Methylene Chloride<br />
0<br />
10 30 50 70<br />
10 30 50 70<br />
Three Successive Injections of Diesel Oil<br />
Normal Injection<br />
Septum changed and liner inspected during run<br />
Normal Injection<br />
PreVent<br />
Isolation Mode<br />
Eliminates downtime during routine injector<br />
maintenance. Can provide approximately 100 extra<br />
analytical hours of productivity per system per year.<br />
ELVI Mode<br />
Facilitates manual injection volumes up to 150 μL<br />
and automatic injection volumes up to 50 μL<br />
without solvent reaching the column or detector.<br />
Time-Saver Mode<br />
Prevents unwanted, high molecular weight material<br />
from reaching the detector. Shortens analysis time,<br />
facilitates isothermal chromatography and protects<br />
the detector from contamination.<br />
ProTect Mode<br />
Eliminates contamination by preventing heavy<br />
components in the sample from reaching the<br />
expensive and retentive chromatographic column.<br />
Allows backflushing during chromatographic run.<br />
PreVent Add-On Kit<br />
Kit includes all necessary hardware to add PreVent capability<br />
to an existing PSS injector with PPC or to a capillary<br />
injector with PPC. Includes restrictor<br />
and mid-point PPC module.<br />
Part No. Each (€)<br />
PreVent Hourglass Guide<br />
PreVent Restrictor<br />
Description Part No. Each (€)<br />
0.06 mm i.d., 108 mm Length N6103080 23<br />
0.06 to 0.25 mm i.d., 104 mm Length N6100342 7<br />
PreVent Spacer<br />
ProTect Add-On Kit<br />
Includes all the necessary parts to add<br />
a ProTect accessory to a Clarus GC.<br />
Includes one ProTect column.<br />
ProTect Replacement Column<br />
MSVent Add-On Kit for the Clarus 500 GC/MS<br />
Includes all the necessary parts to<br />
add an MSVent accessory to a<br />
Clarus GC/MS.*<br />
Part No.<br />
* Requires a PreVent option (N6120144) to be already installed<br />
in the Clarus 500 GC gas chromatograph.<br />
N6120144 2093<br />
Part No.<br />
Each (€)<br />
N6120163 650<br />
Part No.<br />
Each (€)<br />
N6103196 254<br />
Part No.<br />
Each (€)<br />
N6103082 63<br />
Part No.<br />
Each (€)<br />
N6103079 103<br />
Each (€)<br />
N6120179 714<br />
156
Injector Supplies<br />
Injector Liners<br />
Glass Inlet Liners<br />
Inlet liners for split injection have mixing chambers with tortuous flow paths to allow full vaporization of the sample.<br />
Deactivating the surface of these liners prevents active compounds from degrading. Packing the liner with wool will trap<br />
non-volatile residue and prevent column contamination when analyzing dirty samples.<br />
Inlet liners for splitless injection are generally designed as straight tubes, although new designs such as the gooseneck will<br />
help contain the sample in the injector. Packing these liners with wool will also help trap non-volatile residue and prevent<br />
column contamination.<br />
Capillary Split/Splitless Injector Liners<br />
ID OD Length Pk<br />
Description mm mm mm Size Part No. Each (€)<br />
NEW! PSS Splitless Glass Liner Siltek Deactivated Surface Liner (with wool) – 2 4 86.2 5 N6502001 251<br />
General purpose use, ideal for chlorinated pesticides analyses<br />
Split Glass Liner Siltek Deactivated Surface Liner (with wool) – Universal liner for general 4 6.2 92.1 5 N6121020 236<br />
purpose analyses. Surface provides inertness over a wide sample pH range. Wool can<br />
be adsorptive if fibers are broken<br />
NEW! Split Glass Liner (with wool) – 4 6 92.1 5 N6502009 131<br />
Universal liner for general purpose analyses<br />
NEW! Split Siltek Deactivated Glass Liner (with wool) – Universal liner for general purpose 4 6 92.1 5 N6502010 203<br />
analyses. Deactivated surface provides minimal bleed and inertness over a wide<br />
sample pH range<br />
NEW! Clarus Cup Split Glass Liner – Good for both high and low molecular weight 4 6 92.1 5 N6502011 267<br />
compounds. Sample vaporization is aided by tortuous flow path and minimizes<br />
molecular weight discrimination. Difficult to clean<br />
NEW! Clarus Cyclosplitter Glass Liner – Patented cylindrical design for dirty samples, 4 6 92.1 5 N6502012 254<br />
easy to clean and allows many injections before cleaning is required. Not recommended<br />
for large volume injections<br />
Uniliner Deactivated Glass Liner (with wool) – 4 6.2 92.1 5 N6121022 331<br />
Universal liner for general purpose analyses<br />
NEW! Clarus Splitless Glass Liner – Low volume sample analyses, beneficial with 1 6.2 92.1 5 N6502006 164<br />
headspace and purge/trap<br />
Quartz Liner for Splitless Operation (ships with instrument) – 2 6.2 92.1 1 N6121002 22<br />
Standard injector liner<br />
Glass Liner for Splitless Operation – 2 6.2 92.1 1 N6101372 31<br />
Universal liner for general purpose analyses<br />
Deactivated Glass Liner for Splitless Operation (with wool) – 2 6.2 92.1 5 N6121021 109<br />
Good for analyses of trace samples<br />
NEW! Siltek Deactivated Liner (with wool) for Splitless Operation – Optimum sample 2 6.2 92.1 5 N6502004 177<br />
dispertion for active samples. Surface provides inertness over a wide sample pH range.<br />
Wool can be adsorptive if fibers are broken<br />
Quartz Liner for Split Operation – 4 6.2 92.1 1 N6121001 34<br />
Good for large volume injection samples<br />
Glass Liner for Split Operation – 4 6.2 92.1 1 N6101052 29<br />
Universal liner for general purpose analyses<br />
NEW! Siltek Deactivated Double Gooseneck Glass Liner (with wool) – Optimum sample 4 6.2 92.1 5 N6502003 134<br />
dispertion for active samples. Decreases breakdown of active compounds such as<br />
endrin and DDT. Chamber contains sample vaporization cloud. Not suitable for PPC systems<br />
NEW! Cyclo Double Gooseneck Liner for Split Operation – Cylindrical design for large 4 6.2 92.1 5 N6502005 246<br />
volume and trace dirty samples. Decreases injection port discrimination. Cannot be<br />
packed with wool and more difficult to clean<br />
Zero Dilution Glass Outer Liner – Ideal for trace HS work. 2 6.3 90 1 N1011445 74<br />
Use in conjunction with N1011446<br />
Zero Dilution Glass Inner Liner – Ideal for trace HS work. 2 6.3 90 1 N1011446 41<br />
Use in conjunction with N1011445<br />
Column installs at<br />
left side of image.<br />
Injector Supplies Gas Chromatography<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
157
Injector Supplies<br />
Injector Liners<br />
Programmed Temperature Split/Splitless (PSS) Injector Liners<br />
Column installs at<br />
left side of image.<br />
ID OD Length Pk<br />
Description mm mm mm Size Part No. Each (€)<br />
Gas Chromatography Injector Supplies<br />
Packed Column Injector Liners<br />
Column installs at<br />
left side of image.<br />
Quartz Liner for Splitless operation (ships with instrument) – 1 4 86.2 1 N6121006 108<br />
Excellent liner for low volume analyses<br />
NEW! Siltek Deactivated Glass PSS Liner – 1 4 86.2 5 N6502000 343<br />
Used for low volume trace sample analyses<br />
Quartz Liner for Split operation (ships with instrument) – 2 4 86.2 1 N6121004 17<br />
Approved PerkinElmer standard injector liner<br />
NEW! Siltek Deactivated Glass Liner for Split operation 2 4 86.2 5 N6502001 251<br />
(with wool) – Maximum inertness and packed with wool gives<br />
optimum sample dispersion. Surface provides inertness over wide<br />
sample pH range. Wool can be adsorptive if fibers are broken<br />
NEW! Siltek Deactivated Glass Liner for Split operation – Max. 2 4 86.2 5 N6502002 216<br />
inertness gives optimum sample dispersion. Deactivated surface<br />
provides minimal bleed and inertness over a wide sample pH range<br />
Zero Dilution Outer Liner – 2.8 4 83 1 N1011447 90<br />
Use in conjunction with N1011446<br />
Zero Dilution Inner Liner – 2 73 1 N1011446 41<br />
Use in conjunction with N1011447<br />
On-column Glass Liner 2.4 4 86.2 1 N6101539 47<br />
Liner/Hour Glass for POC Injector 2.4 4 19.05 1 N6101703 37<br />
ID OD Length Pk<br />
Description mm mm mm Size Part No. Each (€)<br />
Drilled Uniliner (hole on top) – Excellent liner for high sample 4 6.2 92.1 5 N6121022 331<br />
recovery and linearity, recommended for aqueous injections.<br />
Good for PPC equipped GCs<br />
NEW! Drilled Uniliner (hole on bottom) – Recommended for analysis 4 6.2 92.1 5 N6502013 471<br />
in which compounds of interest could be affected by a tailing<br />
solvent peak. Good for PPC equipped GCs<br />
NEW! Gooseneck Drilled Uniliner (hole on top) – Use for trace, active 4 6.2 92.1 5 N6502014 407<br />
samples, high recovery and linearity<br />
NEW! Gooseneck Drilled Uniliner (hole on bottom) – Use for trace, 4 6.2 92.1 5 N6502015 407<br />
active samples, high recovery and linearity<br />
NEW! Open Top Uniliner (with wool) – Packed with fused silica wool, 4 6.2 92.1 5 N6502016 241<br />
highly recommended for high molecular weight active samples.<br />
The fused silica wool traps dirt and sample residue<br />
NEW! Cyclo Uniliner – Cylindrical design for high molecular weight 4 6.2 92.1 5 N6502017 305<br />
samples provides an excellent vaporization surface. Spiral traps<br />
dirt reducing further residue sample interaction<br />
Wide-Bore Column Glass Liner 6 4 92.1 1 N6101375 29<br />
Wide-Bore Column On/Off Quartz Liner 6 4 92.1 1 N6121003 32<br />
158
Injector Supplies<br />
Injector Septa<br />
Merlin MicroSeal<br />
Merlin MicroSeal Adapter Kit<br />
Increase lifetime with over 2000 injections<br />
2 Step sealing system<br />
Temperature ranges up to 325 °C<br />
Pressure ranges 40 to 100 psi<br />
Low bleed, long life alternative for injector port septa<br />
Quick and easy installation<br />
The Merlin MicroSeal Septa is a unique replacement<br />
septa employing a two-step sealing system and an advanced<br />
elastomer material. Because the syringe needle does not<br />
pierce the septa, there is no debris and ghost peaks are<br />
greatly reduced. The MicroSeal Septa also reduces the<br />
incidence of bent syringe needles and liner contamination.<br />
Usable in either manual or autosampler applications, this<br />
septa can improve your productivity and run reliability.<br />
Designed to be used with 23 gauge straight needle syringes.<br />
Pressure ranges from 4 to 100 psi and injection port<br />
temperatures up to 325 °C. Easy installation on most<br />
PerkinElmer chromatographs.<br />
Merlin MicroSeal Nut<br />
Merlin MicroSeal<br />
Adaptor<br />
High Pressure Merlin MicroSeal Kit:<br />
Includes: 2 Merlin MicroSeal septa,<br />
1 nut, and 1 injection port adapter.<br />
Merlin MicroSeal Septum<br />
Merlin MicroSeal Septa. (pkg 1)<br />
Septa for Use with All Injectors<br />
PTFE-Silicone Injector Septa<br />
Merlin MicroSeal<br />
Septum<br />
Part No.<br />
Maximum recommended operating temperature 300 °C.<br />
11 mm diameter.<br />
Each (€)<br />
N9303344 434<br />
Part No.<br />
Each (€)<br />
N9303345 181<br />
Description Part No. Each (€)<br />
Package of 12 00091357 14<br />
Package of 50 00090652 58<br />
Merlin MicroSeal Septum Cut-Away View<br />
Syringe needle<br />
Syringe needle wiper<br />
O-rings seal needle<br />
during injection<br />
Microseal septum<br />
Duckbill opens easily, seals reliably<br />
BTO TM (Bleed Temperature Optimized) Injector Septa<br />
Maximum recommended operating temperature 300 °C.<br />
Low bleed, high temperature. 11 mm diameter.<br />
Description Part No. Each (€)<br />
Package of 50 N9302972 103<br />
Thermogreen Injector Septa<br />
Maximum recommended operating temperature 350 °C.<br />
Low bleed, high temperature. 11 mm diameter.<br />
Description Part No. Each (€)<br />
Package of 50 N6621028 202<br />
Low Bleed Injector Septa<br />
Maximum recommended operating temperature 320 °C.<br />
11 mm diameter.<br />
Description Part No. Each (€)<br />
Package of 50 N9303343 81<br />
Silicone Injector Septa<br />
Septum nut aligns needle<br />
Septum cup<br />
Spring<br />
Maximum recommended operating temperature 250 °C.<br />
11 mm diameter.<br />
Description Part No. Each (€)<br />
Package of 50 54019985 36<br />
Injector Supplies Gas Chromatography<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
159
Injector Supplies<br />
Subambient Accessories<br />
Gas Chromatography Injector Supplies<br />
PerkinElmer offers subambient systems which are<br />
microprocessor controlled. This control allows precise<br />
injection of coolant for the greatest accuracy. Our design<br />
assures you of minimum thermal gradients, thereby<br />
eliminating the peak splitting often found in<br />
other systems.<br />
NOTE: All of the subambient systems require, but do not include,<br />
PerkinElmer Service installation.<br />
Pressure Ratings<br />
LN 2 20 – 30 psi<br />
CO 2 50 –70 psi<br />
AutoSystem<br />
Subambient Accessories<br />
Liquid Carbon Dioxide (CO 2 ) Subambient Accessory<br />
Contains all of the necessary hardware to add subambient<br />
capability. Capable of operating down to -50 °C. Installation<br />
by PerkinElmer Service is required, but not included.<br />
Part No.<br />
Liquid Nitrogen (LN 2 ) Subambient Accessory<br />
Contains all of the necessary hardware to add subambient<br />
capability. Capable of operating down to -99 °C. Installation<br />
by PerkinElmer Service is required, but not included.<br />
Liquid Nitrogen (LN 2 ) Subambient Accessory<br />
for Temperature Programmable Injectors<br />
Each (€)<br />
N6120017 1977<br />
Part No.<br />
Each (€)<br />
N6120016 1671<br />
Contains all of the necessary hardware to add subambient<br />
capability to two temperature programmable injectors<br />
(PSS/Program Split Splitless, POC/Program On-Column)<br />
on one Gas Chromatograph. Capable of operation down to<br />
-99 °C. Requires but does not include oven LN 2 subambient.<br />
Installation by PerkinElmer Service<br />
is required, but not included.<br />
Part No. Each (€)<br />
N6120078 727<br />
Subambient Accessories<br />
Liquid Carbon Dioxide (CO 2 ) Subambient Accessory<br />
Contains all the necessary hardware to add subambient<br />
capability to AutoSystem XL or Clarus GC. Operating<br />
temperature range down to -50 °C.<br />
Installation by PerkinElmer Service<br />
is required, but not included.<br />
Part No.<br />
N6120159<br />
Each (€)<br />
1231<br />
Liquid Nitrogen (LN 2 ) Subambient Accessory<br />
Contains all the necessary hardware to add subambient<br />
capability to AutoSystem XL or Clarus GC. Operating<br />
temperature range down to -99 °C.<br />
Installation by PerkinElmer Service<br />
is required, but not included.<br />
Part No.<br />
N6120158<br />
Each (€)<br />
1352<br />
160
Injector Supplies<br />
Syringes<br />
Autosampler Syringes<br />
Replacement<br />
Syringe<br />
Needle<br />
Description Volume/o.d. Part No. Each (€) Part No. Each (€)<br />
Low injection volume analysis. 0.5 μL/0.63 N6101252 210 N6101469 74<br />
Plunger type: metal plunger in needle.<br />
Routine analysis. Shipped with instrument. 5 μL/0.63 N6101390 110<br />
Plunger metal plunger in barrel with Teflon ® -tipped seal.<br />
0.53 capillary column on-column injection. 5 μL/0.47 N6101380 113<br />
Plunger type: metal plunger in barrel.<br />
Low injection volume. 0.53 capillary on-column injection. 5 μL/0.47 N6101253 210 N6101470 74<br />
Plunger type: metal plunger in needle.<br />
Routine analysis, plunger type: metal plunger in barrel. 5 μL/0.63 N6101251 110<br />
Metal plunger in barrel type 50 μL/0.47 N9302799 223<br />
50 μL/0.63 N6101760 200<br />
Needle Syringes<br />
Why a 7 cm Needle?<br />
All PerkinElmer injectors have been tested and optimized<br />
for use with a 7 cm needle. A 7 cm needle is critical to be<br />
sure your sample is deposited in the optimal zone.<br />
Point Style 2<br />
General-purpose point style designed for septum penetration<br />
in all chromatographic techniques. The needle has a 22°<br />
bevel with the tip slightly bent to minimize coring and<br />
needle plugging.<br />
Point Style 3<br />
Needle has a 90° bevel. Point style 3 is recommended<br />
when the syringe is used for accurate pipetting of liquids.<br />
Excellent for mixing standards of very small volume.<br />
Fixed Needle Syringes<br />
Syringe P.S. #2 P.S. #3<br />
Capacity Part No. Each (€) Part No. Each (€)<br />
10 μL 00230113 47<br />
10 μL* 00230523 47<br />
25 μL N9302202 52 09904823 52<br />
50 μL N9302203 61 09904941 60<br />
100 μL N9302204 61 09904822 62<br />
Fixed Needle Syringe Six Pack<br />
Contains six syringes (10 μL, fixed<br />
needle, point style #2, 00230523).<br />
Fitted with 7 cm needle.<br />
Removable Needle Syringes (RN)<br />
Part No.<br />
Each (€)<br />
N9302230 236<br />
Syringe P.S. #2<br />
Capacity Part No. Each (€)<br />
10 μL* N9302210 71<br />
25 μL N9302211 78<br />
50 μL N9302212 83<br />
100 μL N9302213 94<br />
250 μL N9302214 110<br />
500 μL N9302215 123<br />
* Standard syringe but fitted with 7 cm needle for PerkinElmer injectors.<br />
Injector Supplies Gas Chromatography<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
161
Injector Supplies<br />
Syringes<br />
Gas Chromatography Injector Supplies<br />
Replacement Needles<br />
for Removable Needle Syringes (RN)<br />
Syringe P.S. #2<br />
Capacity Gauge Length Qty. Part No. Each (€)<br />
10 μL** 26S 7 cm pkg. 3 N9302220 35<br />
10 μL 26S 2 in. pkg. 3 N9302222 35<br />
25 μL 22S 2 in. pkg. 3 N9302224 35<br />
50 μL 22S 2 in. pkg. 3 N9302224 35<br />
100 μL 22S 2 in. pkg. 3 N9302226 35<br />
Replacement Needles for RN Syringes<br />
Needle Gauge Volume Part No. Each (€)<br />
26S 10 μL N9302222 35<br />
22S 25, 50, 100 μL N9302224 35<br />
22S 250 μL N9302226 35<br />
P.S. = Point Style<br />
** Recommended for PerkinElmer injectors.<br />
Syringes – Gas Tight<br />
Fixed<br />
Removable<br />
Syringe Needle (N) Needle (RN)<br />
Capacity Part No. Each (€) Part No. Each (€)<br />
10 μL N9302240 61 N9302241 83<br />
25 μL N9302242 59 N9302243 75<br />
50 μL N9302244 71 N9302245 94<br />
100 μL N9302247 75<br />
250 μL N9302250 78 N9302251 94<br />
500 μL N9302253 78 N9302254 94<br />
1.0 mL N9302256 99 N9302257 111<br />
2.5 mL N9302259 75<br />
5.0 mL N9302262 94<br />
10 mL N9302265 120 N9302266 140<br />
10 mL Gas Tight Syringe Part No. N9302266<br />
Ultramicro Volume Syringes<br />
Recommended for liquid sample injections of less than<br />
5 μL for gas chromatography. Syringes come standard with<br />
needle length of 7 cm – optimum for PerkinElmer injectors.<br />
Syringe Needle Syringe<br />
Capacity Gauge Part No. Each (€)<br />
0.5 μL 25 N9302231 134<br />
1.0 μL 26* 00230111 106<br />
1.0 μL 22 00230177 106<br />
2.0 μL 25 N9302235 123<br />
2.0 μL 23 N9302237 143<br />
5.0 μL 24 00230178 123<br />
* Recommended for PerkinElmer Wide-Bore Capillary Adapter.<br />
162
Laboratory Supplies<br />
Gas Sampling Supplies<br />
Filters and Traps<br />
Carrier Gas Filter for GC/MS<br />
21 in. long with 1/8 in. fitting.<br />
Gas In-line Filter<br />
This in-line filter<br />
removes moisture,<br />
oil, and particulate<br />
from gas <strong>supplies</strong>. Large capacity filter requires fewer filter<br />
changes, and improves baseline stability and chromatographic<br />
results. Free-standing model also available. Maximum<br />
pressure 100 psig. Trap packing can be refilled. Approximate<br />
dimensions: 2 1/4 x 17 in. with 1/8 in. fittings.<br />
Description Part No. Each (€)<br />
Base-Mount Filter N9301177 299<br />
In-line Gas Filter N9301178 200<br />
Packing Refill Kit (sufficient for two refills) N9301176 29<br />
Hydrocarbon Trap<br />
Use our activated charcoal<br />
in-line trap to remove<br />
gaseous hydrocarbons<br />
from carrier gas supply.<br />
This trap will remove all hydrocarbons at room temperature<br />
except methane. <strong>Essential</strong> for purge- and-trap systems, or<br />
high-sensitivity FID operation when contamination is a<br />
problem. Maximum pressure 1000 psig. Frits at the end<br />
prevent any particles from entering the gas stream. Trap is<br />
purged with nitrogen and should be purged with the gas you<br />
plan to use. Approximate dimensions:<br />
2 x 14 in. with 1/8 in. fittings.<br />
Part No. Each (€)<br />
Indicating Oxygen Trap<br />
Indicating trap has a<br />
capacity of 40 cc of<br />
pure oxygen. The trap<br />
has a maximum pressure of 100 psig. The trap is shipped in<br />
the active state purged with hydrogen. It is recommended<br />
that you purge the trap with the gas you will be using.<br />
Approximate dimensions: 1 3/8 x 10 1/4 in. Includes<br />
1/8 in. fittings. It is recommended that<br />
the indicating trap be used downstream Part No. Each (€)<br />
of the high-capacity oxygen trap.<br />
N9301191 159<br />
Gas Flow<br />
High-Capacity<br />
Oxygen Filter<br />
Indicating Oxygen Filter<br />
Indicating<br />
Packing<br />
Part No.<br />
Each (€)<br />
N6471025 293<br />
N9301192 147<br />
Gas Flow<br />
Oxygen Trap<br />
High efficiency oxygen<br />
trap has a capacity of 2.5<br />
liters at room temperature.<br />
It is also effective for removing sulfur compounds such as<br />
hydrogen sulfide and mercaptans. This oxygen trap is for use<br />
with nonoxidizing gases such as; He, Ar, N 2 , and CH 4 . Oxygen<br />
removal to below 70 ppb using normal GC flow rates. The<br />
catalyst is a copper-based material that forms copper oxide<br />
in the presence of oxygen; no gas is produced from this<br />
reaction. This trap is intended for use with gases containing<br />
less than 1% oxygen. The trap is delivered active purged<br />
with nitrogen. (Purging with the gas you will be using is<br />
recommended.) Maximum pressure 1000 psig. Approximate<br />
dimensions: 2 x 14 in. including<br />
fitting end; fittings are 1/8 in.<br />
Part No. Each (€)<br />
Safe Glass Moisture Trap<br />
N9301179 262<br />
In-line moisture trap.<br />
Drierite indicating agent<br />
and Molecular Sieve 5A<br />
are packed in glass which is enclosed in a safety plastic tube<br />
in the event the glass breaks. Unique loading design allows<br />
operation in any orientation without channeling. For use with<br />
pressures up to 100 psig. Designed for use with GC detectors<br />
that require high-purity gases. Recommended for ELCD and<br />
ECD systems in which moisture and contamination are a<br />
problem. Trap is shipped active and purged with nitrogen.<br />
It is recommended that you purge the trap with the gas you<br />
plan to use. Approximate dimensions:<br />
1 3/8 x 10 1/4 in. with 1/8 in. end fittings. Part No. Each (€)<br />
Recommended Filters<br />
N9301193 159<br />
Detector Carrier Gas H 2 Air<br />
ECD Moisture Trap<br />
and Oxygen Trap<br />
ELCD Hydrocarbon Trap* Hydrocarbon Trap<br />
FID Hydrocarbon Trap* Moisture Trap Moisture Trap<br />
FPD Hydrocarbon Trap* Moisture Trap Moisture Trap<br />
MS Indicating Oxygen Trap<br />
NPD Hydrocarbon Trap* Moisture Trap Moisture Trap<br />
PID Hydrocarbon Trap*<br />
TCD Hydrocarbon Trap*<br />
* Oxygen Trap if capillary columns are used.<br />
Note: All gases MUST have a minimum purity of 99.995%.<br />
Gases for either ELCD or mass spectrometer MUST have a<br />
minimum purity of 99.999%.<br />
Laboratory Supplies Gas Chromatography<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
163
Laboratory Supplies<br />
Gas Sampling Supplies<br />
Gas Purification Systems<br />
Gas Chromatography Laboratory Supplies<br />
All-In-One Gas Purification System<br />
The trace contaminant removal available from the<br />
three-cartridge Gas Purification System is now available<br />
in a single-cartridge system. The purifier consists of a<br />
manifold head and an all-welded steel cartridge with a<br />
multiple-layer adsorbent bed to sequentially remove<br />
water, oxygen, sulfur compounds, and hydrocarbons.<br />
The All-In-One Gas Purification System has a capacity for<br />
oxygen of at least 450 cc, enough to purify eight 292 cu. ft.<br />
tanks of 99.995% pure helium. Water capacity is at least<br />
1.7 g, while capacity for hydrocarbons (as n-butane) is<br />
5.2 g. The system comes ready to wall mount, but may be<br />
bench-mounted by removing from the bracket and attaching<br />
to a bench-mount base (included). It is shipped fully<br />
activated and filled with high-purity helium.<br />
Product Part No. Each (€)<br />
Gas Purification System with Trap, 1.8 in. Fittings N9306050 345<br />
Replacement Cartridge N9306051 206<br />
Gas Supply Installation Kit<br />
Including hardware to hook up three gas <strong>supplies</strong> to gas<br />
chromatograph. Kit includes: (1) safety gas flow restrictor<br />
for hydrogen (00090038), (1) restrictor warning tag<br />
(00091216), (1) restrictor tag (00091360), (50 ft.) 1/8 in.<br />
refrigeration grade copper tubing (N9300077), (6) 1/8 in.<br />
Swagelok nut (09903128), (6) 1/8 in. brass front ferrules<br />
(09903129), (6) 1/8 in. brass rear ferrules (09903130),<br />
(3) 1/8 in. Swagelok brass 3-way tee (09903170), (3) 1/4 in.<br />
NPT x 1/8 in. Swagelok adapter (09903795), and (1) 1/4 in.<br />
NPT x 1/8 in. NPT reducer female (09903212).<br />
Part No.<br />
Each (€)<br />
N6500123 211<br />
Three-Cartridge Gas Purification System<br />
This system will provide in-line contaminant removal for<br />
your GC gases. This system has convenient replaceable<br />
cartridges with a visual indicator. The PerkinElmer Gas<br />
system consists of three cartridges in series to reduce<br />
column damaging impurities. The first cartridge in the<br />
system will remove residual hydrocarbons and water from<br />
the carrier gas stream. The second cartridge provides<br />
high-capacity oxygen removal (capacity is at least 1000 cc<br />
of pure oxygen); the third cartridge contains an inorganic<br />
indicator that changes from light green to gray to provide<br />
warning when the high-capacity oxygen trap is depleted.<br />
All systems are helium leak tested after assembly.<br />
Approximate dimensions: 33 cm W x 33 cm H x 8 cm D;<br />
weight 4 kg.<br />
Cartridges are easy to replace<br />
High capacity<br />
Wall bracket gets the system up and out of the way<br />
Product Part No. Each (€)<br />
Gas Purification System, 1/8 in. fittings N9306002 689<br />
complete system (includes all three traps)<br />
Hydrocarbon Moisture Replacement Cartridge N9306003 185<br />
High Capacity Oxygen Replacement Cartridge N9306004 204<br />
Indicating Oxygen Replacement Cartridge N9306005 182<br />
Replacement Cartridge Set, one each N9306048 573<br />
hydrocarbon/moisture, high-capacity oxygen<br />
and indicating oxygen<br />
Bypass Accessory, allows operation of system N9306006 75<br />
when installed in place of cartridge<br />
Bench Mount Adapter N9306014 48<br />
164
Laboratory Supplies<br />
Gas Sampling Supplies<br />
High Purity Brass Regulators<br />
PerkinElmer regulators are constructed of high-purity<br />
brass barstock and have stainless steel diaphragms and<br />
metal-to-metal seals. They are suitable for use with<br />
high-purity (>99.995% pure) non-corrosive gases.<br />
Regulators terminate in a 1/4 in. NPT Swagelok fitting.<br />
Barstock body construction<br />
Stainless steel diaphragms<br />
Metal-to-metal seals<br />
Use with high-purity carrier gas<br />
High-purity Brass Regulators (Dual Stage)<br />
Delivery Cylinder<br />
CGA Delivery Pressure Pressure Gauge<br />
Fitting Pressure Use Range (psig) Gauge (psig) (psig) Part No. Each (€)<br />
CGA-350 H 2 and Ar/CH 4 mixes 4-100 0-250 0-3000 09907128 763<br />
CGA-580 He, Ar 4-100 0-250 0-3000 09907127 763<br />
High-purity Brass Regulators (Single Stage)<br />
Delivery Cylinder<br />
CGA Delivery Pressure Pressure Gauge<br />
Fitting Pressure Use Range (psig) Gauge (psig) (psig) Part No. Each (€)<br />
CGA-350 H 2 and Ar/CH 4 mixes 3-80 0-100 0-3000 00230091 381<br />
CGA-580 He, Ar 10-180 0-250 0-3000 00230253 381<br />
CGA-590* Air 5-180 0-250 0-3000 00230090 381<br />
* Supplied with 590-580 Adapter.<br />
PG-H 2 Pure Gas Hydrogen Generators<br />
The PG-H 2 series Hydrogen Generators employ the newest<br />
membrane technology available for the safe production<br />
of pure hydrogen gas.<br />
The patented DBS PG-H 2 series of Hydrogen Pure Gas<br />
Generators is ideal for operation with gas analyzers, as fuel<br />
gas for flame tools, or as a source of pure hydrogen. Electrolytic<br />
membrane technology is preferred over alternative hydrogen<br />
generating techniques because it is clean, requires less<br />
maintenance, and there is no need to store chemicals<br />
to maintain operation. Only pure water, either distilled<br />
or deionized, is required to provide trouble-free,<br />
long-term operation.<br />
Features and Benefits:<br />
LCD display shows set points, operating conditions and status<br />
Continuous or intermittent operation<br />
Visual operating status lights<br />
Alarm conditions<br />
Flow indicator informs the operator at a glance that hydrogen<br />
gas is flowing at the specified rate<br />
Bi-directional RS232 interface<br />
Selectable auto start<br />
Remote control (optional)<br />
Cascading of 2 or more units (optional)<br />
PC-Control capability<br />
PG-H2 Series<br />
Hydrogen Generator<br />
High-Purity Brass Regulator Part No. 09907128<br />
Safety Straps<br />
Nylon adjustable cylinder safety<br />
straps hold tanks securely to<br />
bench top or wall.<br />
Model/Component Part No. Each (€)<br />
Wall Mount N9301298 101<br />
Bench Mount N9301299 101<br />
Model/Component Part No. Each (€)<br />
Deionizer Bag N9306066 75<br />
Desiccant Cartridge, Fitting, and Refill Kit N9306064 279<br />
Desiccant Refill (pkg. 3) N9306065 101<br />
PG-H2 100 Hydrogen Generator 100 mL/min. N9306058 4322<br />
PG-H2 160 Hydrogen Generator 160 mL/min. N9306059 5200<br />
PG-H2 250 Hydrogen Generator 250 mL/min. N9306060 6000<br />
PG-H2 500 Hydrogen Generator 500 mL/min. N9306061 8000<br />
Laboratory Supplies Gas Chromatography<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
165
Laboratory Supplies<br />
Instrument Pneumatics Accessories<br />
Gas Chromatography Laboratory Supplies<br />
Manual Pneumatics<br />
0-20 mL/min. Flow Accessory<br />
For use when converting a flow<br />
controller for low flow applications.<br />
Auxiliary Gas Pneumatics Box<br />
For use with carrier or combustion gas. 0-100 psig gauge.<br />
This compact unit comes in either wall or bench mount,<br />
with or without toggle valve for quick shutoff. Design<br />
allows several units to be installed together. 1/8 in.<br />
Swagelok fittings for gas inlet/outlet. Mounting screws<br />
included. Dimensions: 15 x 2 x 7 in. (D x W x H).<br />
Description Part No. Each (€)<br />
With Toggle Valve N9302146 784<br />
Without Toggle Valve N9302145 746<br />
Flow Controller and Gauge with Screen Readout<br />
Includes: flow controller, gauge, and<br />
transducer for mounting into an<br />
empty instrument pneumatic panel.<br />
Part No.<br />
PPC Detector Control Pneumatics Add-On Kit<br />
Kit includes parts to add one channel of PPC control for<br />
detector gas to an existing detector. For use with hydrogen<br />
or air on FID, NPD, and FPD; makeup on ECD and PID. The<br />
GC must be PPC ready. If not, a PPC upgrade kit (N6120146)<br />
is required. Requires, but does not include, appropriate<br />
PPC frit (see table).<br />
Note: Do not use for ELCD or TCD makeup. These require special kits with<br />
tees. The AutoSystem XL must be PPC ready. If not, a PPC upgrade kit<br />
(N6120146) is required. Installation by PerkinElmer Service is required,<br />
but not included.<br />
Part No. Each (€)<br />
PPC Flow Control Pneumatics Add-On Kit<br />
for Packed or POC Injector<br />
Each (€)<br />
N6101377 261<br />
Part No.<br />
Each (€)<br />
N6120004 670<br />
N6120148 1192<br />
Kit includes parts to add PPC flow control for carrier gas<br />
to an existing packed or POC injector. Requires but does<br />
not include appropriate PPC frit (see table). The GC must<br />
be PPC ready. If not, a PPC upgrade kit (N6120146) is<br />
required. Installation by PerkinElmer Service is required,<br />
but not included.<br />
Part No. Each (€)<br />
N6120149 2130<br />
PPC Upgrade Kit<br />
Kit includes the main control board and hardware to add<br />
PPC capability to an existing AutoSystem XL or Clarus Gas<br />
Chromatograph. Installation by PerkinElmer Service is<br />
required, but not included.<br />
Part No. Each (€)<br />
Preset Pressure Regulator<br />
Consists of a preset (30 psig) nonadjustable pressure regulator<br />
for use with manual detector gas controls. Recommended for<br />
use on hydrogen and air for FID.<br />
Part No. Each (€)<br />
Pressure Regulator with Screen Readout<br />
Includes pressure regulator (0-60 psig)<br />
and transducer for mounting into an<br />
empty instrument panel.<br />
PPC Frits<br />
N6120146 1354<br />
N6101473 249<br />
Part No.<br />
Each (€)<br />
N6120005 434<br />
Injector/<br />
Detector Gas Frit No. Color Part No. Each (€)<br />
ECD Argon/ 4 Black N6120155 84<br />
Methane<br />
or Nitrogen<br />
FID Air 6 Blue N6120157 84<br />
FID Hydrogen 4 Black N6120155 84<br />
FPD Air 5 Green N6120156 84<br />
FPD Hydrogen 4 Black N6120155 84<br />
NPD Air 5 Green N6120156 84<br />
NPD Hydrogen 1 Silver N6120152 84<br />
Packed Carrier 4 Black N6120155 84<br />
POC Carrier 3 Yellow N6120154 84<br />
POC Carrier Use 2 Red N6120153 84<br />
for Low Flows<br />
(i.e.,
Laboratory Supplies<br />
Maintenance Supplies<br />
Flow Meters<br />
Tools<br />
Digital Flow Meter<br />
The PerkinElmer Model 570 meets ISO 9000 and Good<br />
Laboratory Practice (GLP) requirements. The flow meter<br />
comes with a “Certificate of Calibration” that states all of<br />
the traceability information needed for ISO-9000<br />
compliance. The Model 570 is uniquely indentified by<br />
serial number, internal instrument number, and date(s) of<br />
calibration. It is also capable of periodic recalibration.<br />
Product Part No. Each (€)<br />
Digital Flow Meter N9302974 1016<br />
Replacement Glass for Digital Flow Meter N9303429 80<br />
PerkinElmer Electronic Flowmeter 1000<br />
Flow range 0.1-1000 mL/min.<br />
Operating Temperature 0 to 45 °C<br />
Traceable to NIST Primary Standard<br />
Split Ratio Mode<br />
Accuracy +/- -3%<br />
LCD Alphanumeric Display<br />
The PerkinElmer Flowmeter 1000 allows for rapid real-time<br />
flow measurements. Flow rates measured in mL/min.<br />
(volumetric flow). The PerkinElmer Flowmeter 1000 can<br />
quickly calculate split ratios. Ratios are displayed in real<br />
time. Flowmeter not compatible with corrosive or<br />
flammable gases. Portable operation.<br />
(9 V battery included).<br />
Part No. Each (€)<br />
Soap Bubble Flow Meters<br />
N9307029 842<br />
The glass soap bubble flow meters are calibrated in 1 and<br />
10 mL two-stage or 1, 10, and 100 mL three-stage for easy<br />
flow reading. Bubble meters come complete with liquid<br />
soap, rubber squeeze bulb, miscellaneous-sized plastic tube<br />
pieces to adapt to various fittings, and instructions (stand<br />
required, but not included – N9303314).<br />
Product Part No. Each (€)<br />
Two-stage 00230522 101<br />
Three-stage N9300081 218<br />
Stand N9303314 74<br />
Adjustable Wrench<br />
Adjustable 12 in. steel wrench for cylinder pressure<br />
regulators. Wrench opens out to 1 3/4 in.<br />
Fits all regulators listed in this catalog. Part No. Each (€)<br />
Basic Tool Kit<br />
Tools come in tool box for easy storage and use. Kit includes:<br />
open-end wrench set (6 pc.), screwdriver set (6 pc.), adjustable<br />
wrench (6 in.), chain nose pliers (narrow), wire cutters, and<br />
wire strippers.<br />
Part No. Each (€)<br />
Deluxe Tool Kit<br />
Great for use on all lab<br />
instruments! Kit includes<br />
the following tools: openend<br />
wrench set (6 pc.),<br />
screwdriver set (6 pc.),<br />
adjustable wrench (6 in.),<br />
chain nose pliers (narrow),<br />
wire cutters, wire strippers,<br />
slip-joint pliers (6 in.), long<br />
nose No. 5 stainless steel<br />
tweezers (4 3/8 in.), needle file set (6 pc.), Allen key set<br />
(11 pc. imperial sizes), and Allen key set (9 pc. metric sizes).<br />
Shipped in a plastic tool box for<br />
convenient storage.<br />
Part No. Each (€)<br />
6-Piece, Open-End Wrench Set<br />
Six sizes. Includes:<br />
1/4 x 5/16 in. 5/16 x 3/8 in.<br />
3/8 x 1/16 in. 7/16 x 1/2 in.<br />
1/2 x 9/16 in. 9/16 x 5/8 in.<br />
Tubing<br />
N9301324 55<br />
N9301327 242<br />
N9301328 306<br />
Part No.<br />
Each (€)<br />
N9301325 69<br />
Description Qty. Part No. Each (€)<br />
Precleaned Copper Tubing 50 ft. N9300077 120<br />
Teflon ® Tubing, 1/8 in. o.d. 1 ft. 02506483 3<br />
Teflon Tubing, 1/16 in. o.d. Hall Solvent Lines 1 ft. 09985708 7<br />
Tygon Tubing, 1/4 in. i.d., 3/8 in. o.d. for 1 ft. 02506518 3<br />
Water and Air (not for carrier gas)<br />
Laboratory Supplies Gas Chromatography<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
167
Laboratory Supplies<br />
Valves<br />
Valves<br />
Gas Chromatography Laboratory Supplies<br />
There are two types of valves offered. Internal Volume<br />
sample size is determined by an etched rotor inside the<br />
valve. External Volume sample size is determined by a<br />
sample loop outside the valve. External valves are used<br />
primarily for sample injection and/or switching applications.<br />
A valve used for just switching requires another valve<br />
for sample injection. Valves include nuts and ferrules,<br />
but not loops.<br />
3-Port Valve<br />
Requires 90° actuator and standoff for automatic operation.<br />
Replacement<br />
Max. Max. Valve Rotor<br />
Rotation Temp. Pressure Fitting (in.) Coating Part No. Each (€)<br />
Part No. Each (€)<br />
90° 330 °C 300 psi 1/16 N9302885 548<br />
4-Port Valve<br />
Requires 60° actuator and standoff for automatic operation.<br />
90° 175 °C 400 psi 1/16 N9302809 721<br />
90° 350 °C 300 psi 1/16 N9302813 740<br />
90° 330 °C 300 psi 1/8 N9302817 568<br />
6-Port Valve<br />
Requires 60° actuator and standoff for automatic operation.<br />
60° 175 °C 400 psi 1/16 N9302810 810 N9302897 107<br />
60° 350 °C 300 psi 1/16 N9302814 823 N9302901 107<br />
60° 330 °C 300 psi 1/8 N9302818 644 N9302905 107<br />
8-Port Valve<br />
Requires 45° actuator and standoff for automatic operation.<br />
45° 175 °C 400 psi 1/16 N9302811 899<br />
45° 350 °C 300 psi 1/16 N9302815 905<br />
45° 330 °C 300 psi 1/8 N9302819 740<br />
10-Port Valve<br />
Requires 36° actuator and standoff for automatic operation.<br />
36° 175 °C 400 psi 1/16 N9302812 899 N9302899 107<br />
36° 350 °C 300 psi 1/16 N9302816 905 N9302903 107<br />
36° 330 °C 300 psi 1/8 N9302820* 765<br />
* Special 4 1/8 in. standoff included.<br />
8-Port Valve<br />
Part No. N9302819<br />
168
Laboratory Supplies<br />
Valves/Loops<br />
4-Port Internal Valve and Rotor for Liquid Sample Injection<br />
Replacement<br />
Valve<br />
Rotor<br />
Fixed Volume (μL) Fitting Size Port Diameter Part No. Each (€) Part No. Each (€)<br />
0.06 1/16 in. 0.016 N9302800 810<br />
0.2 1/16 in. 0.016 N9302802 810 N9302889 107<br />
0.5 1/16 in. 0.016 N9302803 810 N9302890 107<br />
2.0 1/8 in. 0.030 N9302808 810<br />
Max. Temp. = 75 °C, Max. Pressure = 500 psi, Fitting Size = 1/16 in.<br />
These valves require a 90° actuator and standoff for automatic operation.<br />
Sample Loops<br />
4-Port Internal Valve and Rotor<br />
Sample Loops<br />
6-Port 8-Port 10-Port<br />
Volume Size Part No. Each (€) Part No. Each (€) Part No. Each (€)<br />
100 μL 1/16 in. N9302851 29 N9302854 29 N9302857 29<br />
100 μL 1/8 in. N9302860 29 N9302866 29<br />
250 μL 1/16 in. N9302852 29 N9302855 29 N9302858 29<br />
250 μL 1/8 in. N9302867 29<br />
500 μL 1/16 in. N9302853 29 N9302859 29<br />
500 μL 1/8 in. N9302862 29 N9302868 29<br />
1 mL 1/16 in. N9302950 48 N9302953 48 N9302956 48<br />
1 mL 1/8 in. N9302962 26 N9302965 28<br />
2 mL 1/16 in. N9302951 48 N9302954 48 N9302957 48<br />
2 mL 1/8 in. N9302960 48 N9302966 29<br />
5 mL 1/16 in. N9302952 48 N9302958 48<br />
5 mL 1/8 in. N9302961 48 N9302967 30<br />
1/8 in. fitting loop for valves with 0.030 in. standard port diameter. 1/16 in. fitting loop for valves with 0.016 in. standard port diameter.<br />
Laboratory Supplies Gas Chromatography<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
169
Laboratory Supplies<br />
Valve Accessories<br />
Adapters<br />
Fused-Silica Adapters<br />
These adapters allow connection of fused-silica to unions, valve ports, and reducers.<br />
Gas Chromatography Laboratory Supplies<br />
Description i.d. Colum i.d. Fitting Part No. Each (€)<br />
0.5 mm 0.18 mm - 0.35 mm 1/16 in. N9302846 49<br />
Fused-Silica Tubing<br />
Stainless Steel Nut<br />
Valve Body<br />
Air Actuators<br />
Rotor<br />
0.6 - 0.8 mm 0.53 mm 1/16 in. N9302847 49<br />
Any 1/16 in. N9302850 6<br />
0.5 mm 0.18 mm - 0.35 mm 1/16 in. N9302848 28<br />
0.6 - 0.8 mm 0.53 mm 1/16 in. N9302849 28<br />
Any 1/16 in. N9302886 6<br />
Removable Polyimide Liner<br />
Polyimide<br />
Ferrule<br />
Slot<br />
Standard Port Diameter<br />
For Use With Degree Rotation Part No. Each (€)<br />
3- and 4-port valves 90° N9302882 293<br />
6-port valves 60° N9302881 293<br />
8-port valves 45° N9302825 293<br />
10-port valves 36° N9302827 293<br />
Actuator Knob<br />
Part No. N9302913<br />
Actuator Knob<br />
Manual knob allows manual switching of valves. Can be used<br />
with any valve or standoff listed,<br />
except closemount assembly.<br />
Air Actuator Extension Kit<br />
Angle Bracket<br />
Part No. N9300090<br />
Extension screw allows easy tightening of<br />
the air actuator to the standoff. Required<br />
on AutoSystem Series/Clarus GC.<br />
Closemount<br />
Part No. N9302908<br />
Part No.<br />
Part No.<br />
Each (€)<br />
N9302913 18<br />
Each (€)<br />
N9300088 18<br />
Angle Bracket<br />
General purpose bracket for<br />
mounting standoff and actuators.<br />
Closemount Assembly<br />
Allows close mounting of actuator and valve. Primarily used<br />
for mounting valve outside oven. (Not<br />
to be used with manual actuator knobs) Part No. Each (€)<br />
Restrictor<br />
Rotor Removal Tool<br />
Part No.<br />
At ambient conditions, flows range<br />
from 2-200 mL/min. (inlet at 15 psi).<br />
Includes: stainless steel lines (18 in.<br />
long, 1/16 in. o.d., 0.020 in. i.d.) and<br />
inlet filter.<br />
Part No. Each (€)<br />
Magnet end allows easy removal<br />
of rotor from valves.<br />
Each (€)<br />
N9300090 27<br />
N9302908 42<br />
N9302823 210<br />
Part No.<br />
Each (€)<br />
N9302914 7<br />
170
Laboratory Supplies<br />
Valve Accessories<br />
Special Standoff for 10-Port Valve<br />
This standoff will allow connection<br />
of a 10-port 1/8 in. valve to the<br />
AutoSystem Series/Clarus GC.<br />
Part No. Each (€)<br />
N9302781 54<br />
Starter Kit<br />
Part No. Each (€)<br />
N9302821 427<br />
Standoffs<br />
A standoff supports both the actuator and the valve.<br />
The standoff places the valve at the specific distance<br />
from the actuator. A 4 1/8 in. standoff is recommended<br />
for mounting valves in PerkinElmer GC ovens. Standoff<br />
and actuator sold separately.<br />
Length Part No. Each (€)<br />
2 in. N9302909 51<br />
3 1/4 in. N9302910 51<br />
4 1/8 in. N9302911 51<br />
6 in. N9302912 51<br />
Kits<br />
Sample Loop<br />
Air Actuator<br />
Mounting Kit<br />
Solenoid Kit<br />
Fitting<br />
Solenoid<br />
Sample Valve<br />
Mounting Bracket<br />
Column<br />
Kit includes all necessary hardware to install valves on<br />
AutoSystem Series/Clarus GC. Each kit is capable of<br />
mounting up to two gas valves inside the oven. Includes<br />
detailed instructions that show how to use gas valves,<br />
set up timed events, and configure<br />
the AutoSystem GC software.<br />
Part No. Each (€)<br />
N6120033 395<br />
Kit is required for each air actuator. Solenoid Kit allows<br />
precise pulse of air needed to drive air actuator. Kit<br />
includes instructions. For use with<br />
AutoSystem Series/Clarus GC only. Part No. Each (€)<br />
N6120032 287<br />
Kit includes:<br />
Description Qty. Part No.<br />
2u Screen Filter for use with 6 N9302880<br />
Replacement Filters for N9302879<br />
Filter Union 1/16 in. with Removable 1 N9302879<br />
Screen for use with Gas Line Filter<br />
Reducer 1/8 in. Swagelok to 1/16 in. 4 N9302917<br />
Valco for Packed Column Adapter<br />
Reducer 1/8 in. Swagelok Male Nut 2 N9302844<br />
to 1/16 in. Valco<br />
for Injector/Detector Adapter<br />
Stainless Steel Tubing, 50 cm, 2 N9302922<br />
1/16 in. o.d. to 0.02 in. i.d.<br />
for Carrier to detector<br />
Stainless Steel Tubing, 125 cm, 2 N9300087<br />
1/16 in. o.d. to 0.02 in. i.d.<br />
for Sample Input/Output<br />
Valco Ferrule 1/16 in. 10 N9302835<br />
Valco Nut 1/16 in.* 6 N9302832<br />
* Cannot be used with fused-silica adapters (N9302846 or N9302847).<br />
Tubing Kits<br />
Particulate contamination is the leading cause of valve<br />
failure. This tubing has been washed and precleaned, with<br />
solvent and microfiltered steam from deionized water to<br />
remove organic and ionic particulate contamination.<br />
Each kit contains two pieces of 1/16 in. o.d. S/S tubing.<br />
0.02 in.<br />
Length Part No. Each (€)<br />
20 cm N9302871 11<br />
30 cm N9302872 10<br />
50 cm N9302922 17<br />
125 cm N9300087 114<br />
Laboratory Supplies Gas Chromatography<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
171
Laboratory Supplies<br />
Valve Fittings<br />
Gas Sampling Valve Fittings<br />
Ferrules<br />
Description Qty. Part No. Each (€)<br />
1/16 in. stainless steel pkg. 1 N9302835 5<br />
1/8 in. stainless steel pkg. 1 N9302836 5<br />
Gas Chromatography Laboratory Supplies<br />
Plugs and Caps<br />
Reducers<br />
3/8 in. HEX<br />
1/4 in. HEX<br />
Standard Nuts<br />
Unions<br />
1/4 in. HEX<br />
1/4 in. HEX<br />
7/16 in. HEX<br />
7/16 in. HEX<br />
Description Qty. Part No. Each (€)<br />
1/16 in. plug pkg. 1 N9302918 8<br />
1/8 in. plug pkg. 1 N9302919 8<br />
1/16 in. cap pkg. 1 N9302920 10<br />
1/8 in. cap pkg. 1 N9302921 10<br />
Description Qty. Part No. Each (€)<br />
1/8 in. Swagelok TM to 1/16 in. Valco pkg. 1 N9302917 24<br />
1/16 in. adapter for 1/16 in. port pkg. 1 N9302843 14<br />
Description Qty. Part No. Each (€)<br />
1/16 in. pkg. 1 N9302832 5<br />
1/8 in. pkg. 1 N9302833 3<br />
Description Qty. Part No. Each (€)<br />
1/16 in. to 1/32 in. reducing union pkg. 1 N9302838 60<br />
1/16 in. union pkg. 1 N9302839 36<br />
1/8 in. to 1/16 in. reducing union pkg. 1 N9302840 36<br />
1/8 in. union pkg. 1 N9302841 17<br />
172
TotalChrom<br />
Software<br />
TotalChrom Data Handling Systems<br />
Chromatography Data Systems<br />
A proven solution with leading edge productivity.<br />
Streamlining Your Laboratory Workflow<br />
The entire process, from setting up an analytical method<br />
to the final approval of reports, is a streamlined series of<br />
operations in TotalChrom.<br />
TotalChrom features TC Publisher, a powerful application<br />
that extends report capabilities beyond the standard<br />
templates by providing a sophisticated laboratory report<br />
generator using standardized tools. Unique features let<br />
you graphically format the exact report as needed without<br />
extensive training or special commands. It ensures that<br />
the stages of chromatographic analysis, report generation<br />
and distribution are quick, easy, and complete.<br />
low resolution image<br />
TotalChrom Navigator Screen<br />
PerkinElmer’s TotalChrom Chromatography Data System is<br />
designed to provide laboratories with the total answer to<br />
chromatography data-handling needs.<br />
Acquiring, processing, reporting, reviewing, and approving<br />
data is a streamlined series of operations in PerkinElmer’s<br />
TotalChrom Chromatography Data Systems (CDS), software<br />
designed to fit your laboratory workflow and maximize<br />
productivity. With its scalable architecture, 21 CFR Part<br />
11 compliance features and proven algorithms, TotalChrom<br />
offers a computing strategy to manage your chromatography<br />
data quickly and securely in both regulated and<br />
non-regulated environments.<br />
When configured with a PerkinElmer Clarus 500 Gas<br />
Chromatograph or a PerkinElmer Series 200 Liquid<br />
Chromatograph, the TotalChrom Data System is the<br />
controller and data manager for the overall system. In addition,<br />
TotalChrom can also control selected instruments from other<br />
vendors and can acquire data from<br />
any chromatographic system<br />
through A/D interface.<br />
Report templates can perform calculations between different<br />
peaks in the same sample or even between samples, as<br />
well as automate statistical determination for replicate<br />
injections, with full control over the output format.<br />
Quickly and Easily Navigate,<br />
Review, and Approve Your Data<br />
In the “paper world,” reports need to be reviewed and<br />
signed. The TotalChrom Review & Approve (R&A) feature<br />
is a Graphical Reviewing environment that allows intuitive<br />
navigation into data and reports, and provides for the<br />
implementation of a data approval cycle. With TotalChrom<br />
R&A, chromatograms, raw data, results, and reports can<br />
be easily viewed and compared at a glance. Reviewing and<br />
approving reports can be done electronically, with multiple<br />
levels of authority and secure electronic signatures.<br />
High-throughput applications have dramatically increased the<br />
amount of information produced every day in a laboratory.<br />
This feature streamlines tedious data review by using one<br />
single environment to navigate into data, just like we, every<br />
day, navigate into e-mail.<br />
TCPublisher<br />
Replicate Injections Report<br />
TotalChrom Client/Server (TC<br />
C/S) Data System is the solution<br />
in multi-user environments. TC<br />
C/S systems can easily integrate<br />
all existing chromatographs into a<br />
single networked system supporting<br />
an unlimited number of users<br />
and an unlimited number<br />
of chromatographs.<br />
TCPublisher<br />
Single Injection Report<br />
TCPublisher<br />
Dual Channel Report<br />
www.perkinelmer.com/<strong>supplies</strong> 173
Software<br />
Intelligent Interfaces<br />
Software<br />
Gas Chromatography<br />
dotLINK<br />
dotLINK – Interfacing with ease.<br />
All totalchrom systems utilize PerkinElmer Intelligent<br />
Interfaces to connect each chromatography system to the<br />
data system PC. Each interface contains buffered RAM<br />
memory to maintain data collection in the event that the PC<br />
or PC network becomes inoperative during data acquisition.<br />
Data from instruments is never lost and chromatograph<br />
productivity is preserved.<br />
Analog chromatographs connect to TotalChrom through<br />
NCI (Network Chromatograpy Interface) Series Intelligent<br />
Interfaces. The model NCI 901 is a single-channel device,<br />
while the model NCI 902 is a dual-channel device. Both<br />
interface models are capable of taking analog detector data<br />
(unipolar or bipolar) at sampling rates from 0.1 to 100 Hz.<br />
dotLINK is a Windows ® CE-based interface that allows you<br />
to connect your Clarus GC, Agilent 1100 GC, Agilent 6890 GC,<br />
and Series 200 HPLC directly to the network. Designed to face<br />
today’s workload challenges and provide Ethernet connectivity,<br />
dotLINK allows external buffering with a minimal need for<br />
validation. The dotLINK box integral link has a small<br />
footprint, providing valuable space for your laboratory.<br />
dotLINK supports the following GC and HPLC configurations:<br />
Maximum of 3 PerkinElmer Clarus GCs<br />
Maximum of 1 PerkinElmer Series 200 HPLC System Stack<br />
Maximum of 2 Agilent 6890 GCs<br />
Maximum of 1 Agilent 1100 HPLC/UV System Stack<br />
dotLINK<br />
Recommended<br />
Model Applications Memory Part No. Each (€)<br />
dotLINK 1-3 Clarus 500 GCs 1 MB N5150060 3314<br />
Integral Link<br />
Integral Link for Clarus GC<br />
Provides a digital-to-digital connection between the Clarus<br />
GC and TotalChrom. Requires AutoSystem XL IPM for<br />
TotalChrom Workstation or Client/Server Software.<br />
Also requires appropriate cable for<br />
connection to TotalChrom system. Part No. Each (€)<br />
N6513010 887<br />
Integral LINK for Clarus GC and<br />
TotalChrom Workstation Software<br />
Provides digital-to-digital connection between the Clarus<br />
GC and TotalChrom Chromatography Workstation or the<br />
Clarus 500 Mass Spectrometer. Includes Integral LINK,<br />
TotalChrom Workstation Software,<br />
AutoSystem XL IPM, and serial cable. Part No. Each (€)<br />
Analog Board with Integral LINK*<br />
Description Part No. Each (€)<br />
Analog Board with Integral LINK N6513060 1153<br />
Analog Board with Integral LINK N6513070 4844<br />
and TotalChrom Workstation Software<br />
* For ARNEL Analyzers only.<br />
NCI Intelligent Interfaces<br />
NCI Series Intelligent Interfaces are 24 bit, either single or<br />
dual-channel, buffered, A/D converters which have softwareselectable<br />
input voltage ranges of 10, 2, 1, and 0.1 V with 6<br />
decade dynamic range, programmable sampling rates from<br />
0.1 to 100 points per second selectable in TotalChrom<br />
software, less than 1 microvolt noise (peak to peak), 0.1%<br />
linearity, three sense input lines, and one-system READY<br />
relay for communication with Autosamplers. Includes: a<br />
board containing seven programmable relays and a<br />
Rack/Vial Port (TTL voltage levels) for reading Autosampler<br />
vial BCD information. Memory is segmentable for multiple<br />
chromatograms. Software selectable symmetric bipolar or<br />
unipolar mode operation. All Interfaces carry a 1-year<br />
return to Service Depot warranty.<br />
Model NCI 901 Intelligent Interface<br />
with RVP/Relay Board<br />
Single-channel A/D with 256KB RAM memory and RVP/<br />
Relay board. Stores up to 120K data points. Unipolar/<br />
bipolar operation modes. Requires but does not include<br />
one IEEE or RS232 interface cable. Includes power cord.<br />
Voltage Part No. Each (€)<br />
120 V S9000070<br />
240 V S9000075 2671<br />
Model NCI 902 Intelligent Interface<br />
with RVP/Relay Board<br />
N6513020 3756<br />
Dual-channel A/D with 256KB RAM memory and RVP/<br />
Relay board. Stores up to 120K data points. Unipolar/<br />
bipolar operation modes. Requires but does not include<br />
one IEEE or RS232 interface cable. Includes power cord.<br />
Voltage Part No. Each (€)<br />
120 V S9000090<br />
240 V S9000095 4010<br />
174
Software<br />
Intelligent Interfaces<br />
Power Cords – 240 V<br />
No charge when ordered with 240 V Interface.<br />
Country Part No. Each (€)<br />
UK, Cyprus, Nigeria, Zimbabwe, Singapore, 09991414 41<br />
Malaysia, Zambia<br />
Australia, New Zealand 09991417 23<br />
Europe, Saudi Arabia, Egypt, South Africa, India, 09991415 30<br />
Thailand, China<br />
Denmark, Greenland 09991416 27<br />
Switzerland, Liechtenstein 09991413 25<br />
SoftLINK<br />
SoftLINK – Entry-level solution for instrument connectivity.<br />
Designed for workstation environments, SoftLINK TM provides<br />
instrument connectivity at a glance. SoftLINK is able to<br />
control 1 Series 200 HPLC/UV or up to 3 Clarus GC.<br />
SoftLINK/TotalChrom Workstation Software<br />
Includes: appropriate cable for connection of SoftLINK to<br />
TotalChrom system, TotalChrom<br />
software, and Clarus 500 GC IPM.** Part No. Each (€)<br />
SoftLINK Software Kit<br />
Includes: appropriate cable for connection to TotalChrom<br />
system, SoftLINK software CD,<br />
utilities CD, and the install sheet. Part No. Each (€)<br />
USB to Serial Adapter for SoftLINK<br />
One serial port is required for each<br />
Clarus 500 GC. Additional ports can<br />
be added via this USB converter.<br />
** SoftLINK is not available with PerkinElmer-ARNEL systems.<br />
N6513040 3098<br />
N6520235 106<br />
Part No.<br />
Each (€)<br />
09410077 79<br />
Software Gas Chromatography<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
175
Software<br />
Interface Modules<br />
Interface Personality Modules (IPM)<br />
Interface Validation Modules (IVM)<br />
Gas Chromatography Software<br />
IPMs are instrument-specific software programs that<br />
interpret and translate instrument control and data<br />
acquisition parameters between TotalChrom TM and a specific<br />
digital instrument. IPMs are downloaded from the host PC<br />
(TotalChrom) by a configuration function to a specific port.<br />
(Serial or Ethernet) on a dotLINK interface (internal or<br />
external). Downloaded IPMs are stored in nonvolatile<br />
memory in the dotLINK interface.<br />
IPM for AutoSystem, AutoSystem XL,<br />
and Clarus GCs<br />
Provides control for the PerkinElmer AutoSystem Series<br />
and Clarus GCs and their associated liquid Autosampler,<br />
with simultaneous digital data acquisition from two inboard<br />
detectors. Utilizes one serial port on a dotLINK interface and<br />
may be configured to any port or ports on any LINK interface<br />
or interfaces connected to a single TotalChrom acquisition<br />
system. For TotalChrom Professional<br />
users, v4.0 or higher is required, but Part No. Each (€)<br />
not included.<br />
N5150160 494<br />
IPM for Agilent 5890 Series II and Agilent 5890A GCs<br />
Provides control for the Agilent Series 5890 GCs and their<br />
associated liquid Autosamplers, with simultaneous digital<br />
data acquisition from two inboard detectors. Utilizes one<br />
serial port on a Model 600 LINK Series interface and a<br />
second port for each associated Autosampler that is to be<br />
controlled. This IPM may be configured to any port or ports<br />
on any LINK interface or interfaces connected to a single<br />
TotalChrom acquisition system. Requires one serial cable<br />
for each connected Agilent GC and one serial cable for<br />
each connected Autosampler. For TotalChrom Professional<br />
users, v4.0 or higher is required, but not included. Note:<br />
Each Agilent 5890 and 7673 autosampler must have the<br />
appropriate Agilent serial external<br />
controller card(s) and remote start Part No. Each (€)<br />
cable installed.<br />
N5150165 494<br />
IPM for Agilent 6890/6890Plus<br />
Provides control for the Agilent Series 6890 GCs and their<br />
associated liquid Autosampler, with simultaneous digital<br />
data acquisition from two inboard detectors. Utilizes one<br />
serial port on a dotLINK. This IPM may be configured to<br />
any port or ports on any LINK interface or interfaces<br />
connected to a single TotalChrom acquisition system. It is<br />
recommended that no more than two Agilent 6890 GCs be<br />
configured per workstation LINK interface. Requires one<br />
serial cable for each connected Agilent<br />
GC. Control of the Agilent 6890/<br />
Part No. Each (€)<br />
6890Plus is not available for TC Pro. N5150166 494<br />
Model 520 Interface Validation Module, 120 V<br />
The Model 520 IVM is a calibrated analog peak pattern<br />
generator for use in testing/validating analog to digital<br />
converters such as the NCI 901/902 and the Series 900/900A<br />
Intelligent Interfaces. The module generates eight possible<br />
analog patterns at selectable voltage ranges of 0-0.1, 0-1, 0-2,<br />
and 0-10 volts. Factory calibration is traceable to a NIST<br />
standard volt. Includes remote start/stop cable and analog<br />
signal cable for connection to PerkinElmer NCI/900/900A<br />
Series Intelligent Interfaces. Includes 1-year return to<br />
Service Depot warranty.<br />
Voltage Part No. Each (€)<br />
120 V S9000160<br />
240 V S9000165 2586<br />
TotalChrom Workstation Model 520 IVM Software<br />
Allows user to test any NCI Series and M900A Series<br />
Intelligent Interfaces to validate interface operations<br />
(linearity, reproducibility, etc.). Contains special TotalChrom<br />
interface test methods and automated validation logs to<br />
maintain results of interface tests in software.<br />
Requires, but does not include, a<br />
Model 520 Interface Validation Module. Part No. Each (€)<br />
N5150181 314<br />
176
Software<br />
Serial Cables<br />
IEEE Cables – All TC Versions<br />
Serial Cables<br />
Cable Length Part No. Each (€)<br />
1 m 65105001 153<br />
2 m 65105102 173<br />
4 m 65105204 184<br />
8 m 65105408 230<br />
External Communications Cable<br />
Shielded DB9 Male/Female 9-pin<br />
external RS-232 communications cable.<br />
For M941/M600 LINK Interfaces<br />
Cable Length Part No. Each (€)<br />
7 ft. S5010021 32<br />
25 ft. S5010022 38<br />
50 ft. S5010023 51<br />
100 ft. S5010024 64<br />
For M950/970 Interfaces<br />
Cable Length Part No. Each (€)<br />
7 ft. S5010017 32<br />
25 ft. S5010018 38<br />
50 ft. S5010019 51<br />
100 ft. S5010020 64<br />
For NCI Interfaces<br />
Cable Length Part No. Each (€)<br />
7 ft. S5010037 63<br />
25 ft. S5010038 71<br />
50 ft. S5010039 64<br />
100 ft. S5010040 77<br />
For dotLINK Interfaces<br />
Cable Length Part No. Each (€)<br />
10 ft. 09290144 19<br />
25 ft. 09290145 47<br />
For M941A and M600/610 Link Interfaces<br />
Cable Length Part No. Each (€)<br />
7 ft. S5010025 46<br />
25 ft. S5010030 52<br />
50 ft. S5010031 64<br />
100 ft. S5010032 77<br />
For NCI Interfaces<br />
Part No.<br />
TotalChrom TM WS and C/S Serial<br />
Cables to Lantronix Terminal Server<br />
TotalChrom WS and<br />
C/S Serial Cables to PC<br />
Cable Length Part No. Each (€)<br />
7 ft. S5010033 46<br />
25 ft. S5010034 52<br />
50 ft. S5010035 64<br />
100 ft. S5010036 77<br />
Agilent 6890 – HS40/ATD400 Ready/Run Cables<br />
Each (€)<br />
N6500133 181<br />
Description Part No. Each (€)<br />
Cable Kit, HS40/ATD400 to Agilent 6890 N6100410 149<br />
Cable Kit, M950/970 Series Interface to Agilent 6890 N6100411 159<br />
Serial Cables* for Instrument Interface<br />
Description Part No. Each (€)<br />
PerkinElmer Clarus GC to dotLINK, 10 ft. 09290146 19<br />
PerkinElmer Clarus GC to dotLINK, 25 ft. 09290147 47<br />
PerkinElmer Clarus GC 65609010 223<br />
to M600/M610 LINK, 10 ft.<br />
PerkinElmer Clarus GC 65609025 300<br />
to M600/M610 LINK, 25 ft.<br />
M900/960/970 Series Interface to M600/M610 S5010013 223<br />
LINK, 6 ft. (not for M941)<br />
NCI Series Interface to dotLINK, 7 ft. S5010037 63<br />
NCI Series Interface to M600/M610 LINK, 6 ft. S5010041 223<br />
Agilent 1100 GC-Autosampler to dotLINK, 10 ft. 09290144 19<br />
(Required quantity: 3)<br />
Agilent 1512A Autosampler Controller S5010015 223<br />
(on 5890GC) to M600/M610 LINK, 10 ft.<br />
Agilent 1512A Autosampler Controller S5010016 300<br />
(on 5890GC) to M600/M610 LINK, 25 ft.<br />
Agilent 5890A/Series II GC 65605810 223<br />
to M600/M610 LINK, 10 ft.<br />
Agilent 6890 GC/-Agilent 6890Plus GC- 09290144 19<br />
Autosampler to dotLINK, 10 ft.<br />
Agilent 6890 GC/-Agilent 6890Plus GC- 09290145 47<br />
Autosampler to dotLINK, 25 ft.<br />
Agilent 6890 GC/-Agilent 6890Plus GC- S5010015 223<br />
Autosampler to M600/M610 LINK, 10 ft.<br />
Agilent 6890 GC/-Agilent 6890Plus GC- S5010016 300<br />
Autosampler to M600/M610 LINK, 25 ft.<br />
Agilent 7673A Autosampler Controller 65607610 223<br />
(on 5890GC) to M600/M610 LINK, 10 ft.<br />
Agilent 7673A Autosampler Controller 65607625 300<br />
(on 5890GC) to M600/M610 LINK, 25 ft.<br />
* Special serial cards, instrument communication kits, and IPM software<br />
may be required to complete interfacing of a LINK interface to a digital<br />
chromatograph. Please contact your local PerkinElmer Sales Representative<br />
for details.<br />
M900 Series BCD Cables for Autosamplers<br />
Description Part No. Each (€)<br />
PerkinElmer HS100, HS101, ATD50, AS2000, AS8300 65204501 230<br />
Software Gas Chromatography<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
177
Software<br />
Software Kits<br />
Serial Communications<br />
Cards for TurboChrom<br />
TotalChrom Workstation<br />
SI/DI Upgrade Kits<br />
Gas Chromatography Software<br />
Agilent 5890A/Series II GC<br />
Description Part No. Each (€)<br />
Serial Card S2000203 2360<br />
Agilent 7673A Controller<br />
Description Part No. Each (€)<br />
Remote Start Cable S2000206 102<br />
Serial Card and Control Board S2000205 2928<br />
Serial Card and EPROM S2000204 638<br />
TotalChrom Workstation Manuals<br />
Application Manager’s Guide<br />
Application Manager’s Guide covering<br />
installation and system management<br />
of TotalChrom Workstation software.<br />
Manual Set<br />
Complete manual set including User’s<br />
Guide (volumes 1 and 2), Application<br />
Manager’s Guide, and Tutorial.<br />
TotalChrom Tutorial<br />
Software tutorial that teaches basic data acquisition, method<br />
development, optimization techniques,<br />
sequence development, and calibration. Part No. Each (€)<br />
User’s Guide (Volumes 1 and 2)<br />
User’s manual covering instrument<br />
configuration and basic operation<br />
of TotalChrom TM Workstation software.<br />
Part No.<br />
Each (€)<br />
N5156025 128<br />
Part No.<br />
Each (€)<br />
N5150512 383<br />
N5156021 70<br />
Part No.<br />
Each (€)<br />
N5150518 255<br />
v6.x Workstation Migration to v6.3.x Workstation<br />
Migrates an existing TurboChrom TM Workstation<br />
v4.x or v6.x acquisition system, and associated RPO<br />
systems, to TotalChrom Workstation v6.3.x software.<br />
Requires verification of ownership of TurboChrom<br />
v6.x software. Software supplied on<br />
CD-ROM media v4.x or v6.x.<br />
Part No. Each (€)<br />
N5150349 1140<br />
v6.2.x Workstation Migration to v6.3.x Workstation<br />
Migrates an existing TotalChrom Workstation v6.2.x<br />
acquisition system, and associated RPO systems, to<br />
TotalChrom Workstation v6.3.x software. Requires<br />
verification of ownership of TotalChrom v6.2.x software.<br />
Software supplied on CD-ROM media.<br />
Part No. Each (€)<br />
TotalChrom Workstation Software<br />
N5150715 855<br />
Description Part No. Each (€)<br />
Multi-Instrument Software Kit N5150103 3704<br />
Reprocess-Only Software Kit N5150100 542<br />
178
Thermal Desorbers<br />
TurboMatrix Thermal Desorbers<br />
TurboMatrix<br />
Thermal Desorbers for GC<br />
... driving unrivaled Performance<br />
through Innovation.<br />
Thermal desorption is a technique that simplifies and speeds a wide range of gas<br />
chromatography (GC) applications, including indoor and outdoor air monitoring, analysis<br />
of outgassing from semiconductor materials, polymers, upholstery and furnishings,<br />
packaging, pharmaceuticals, and analysis of flavors and fragrances.<br />
As the undisputed market leader in GC sample handling, we took the next step to offer you<br />
even more benefits for your lab. PerkinElmer offers a family of five different TurboMatrix TM<br />
Thermal Desorber (TD) models in both single-tube and automated 50-tube configurations:<br />
■ TurboMatrix 100 TD – single-tube and manual pneumatics<br />
■ TurboMatrix 150 ATD – 50-tube autosampler and manual pneumatics<br />
■ TurboMatrix 300 TD – single-tube and programmable pneumatic control<br />
■ TurboMatrix 350 ATD – 50-tube autosampler and programmable pneumatic control<br />
■ TurboMatrix 650 ATD – 50-tube autosampler, programmable pneumatic control<br />
and a variety of other accessories for a wide range of applications<br />
This broad offering allows you to match technology<br />
to your laboratory and applications needs.<br />
Confirmatory Analysis<br />
The TurboMatrix 650 ATD allows samplesplit<br />
re-collection on same or different<br />
tubes, delivering the ability to audit<br />
samples and perform confirmatory<br />
analysis and repeat analysis under a<br />
different set of conditions.<br />
Integrity Testing<br />
Sensors monitor all aspects of system<br />
operation to ensure that the instrument<br />
is working as it should and provide an<br />
early indication of possible problems<br />
with the analysis. Analytical techniques<br />
such as tube and trap impedance testing<br />
and the standard addition options help<br />
ensure sample integrity. All of these<br />
are designed to provide the user with<br />
the highest confidence in the final<br />
analytical results.<br />
Reduced Cost Per Sample<br />
The TurboMatrix Thermal Desorbers<br />
save money and minimize laboratory<br />
waste. After each use, all sample tubes<br />
can be reconditioned and conveniently<br />
reused. The system provides cryogenfree<br />
operation down to -30 °C, reducing<br />
operating costs. Unlike other techniques,<br />
thermal desorption requires no solvents,<br />
thus reducing cost, risk of contamination,<br />
analyst exposure and the need for<br />
solvent disposal.<br />
Maximize Sample Throughput<br />
Since the thermal desorber unit can<br />
run simultaneously with the GC, you<br />
can start your next desorption run as<br />
the GC processes the previous run for<br />
maximum productivity.<br />
■ Improved chromatography and narrow peak widths<br />
as a result of 40 °C per second trap heating rate<br />
■ Higher productivity with overlapping tube<br />
desorption and chromatography<br />
■ Wider boiling range analysis and improved water<br />
management using the backflush mode, where<br />
multiple adsorbents can be used in series<br />
■ Uncompromised narrow-bore capillary<br />
chromatography due to rapid desorption<br />
of the focusing trap (40 °C per second)<br />
179
Thermal Desorbers<br />
Ozone Precursor Accessories<br />
Gas Chromatography Thermal Desorbers<br />
Air Toxics Columns<br />
Methyl Silicone Column<br />
For use with Air Toxics TM (T014)<br />
Analyzer System with FID/ECD<br />
detectors. 100 m x 0.32 mm i.d. x 5 μm.<br />
Methyl Silicone Column<br />
The STS 25 is used for sequential sampling of air onto a<br />
series of up to 24 ATD sample tubes. It is a portable unit<br />
and can be operated either by a 12 V battery or 120/240 V.<br />
The sampler includes cables with jack plug connectors<br />
(for use with the monitoring pump) and a set of diffusion<br />
limiting caps. The STS 25 requires but does not include<br />
sample tubes and a monitoring<br />
pump. Also requires a 12 V<br />
Part No. Each (€)<br />
battery or an electrical adapter.<br />
L4280001 6600<br />
12 V Rechargeable Battery<br />
Waterproof, suitable for outdoor use.<br />
Air Monitoring Pump<br />
120 V<br />
Cable<br />
For connecting the STS-25 to<br />
a generic 12 V battery.<br />
Part No.<br />
Each (€)<br />
N6300155 1836<br />
For use with the Air Toxics (T014) Analyzer System<br />
with Mass Spectrometer<br />
60 m x 0.32 mm i.d. x 5 μm.<br />
Part No. Each (€)<br />
Model STS 25 Sequential<br />
Tube Sampler<br />
Model STS 25 Accessories<br />
N9316000 993<br />
Part No.<br />
Each (€)<br />
L4280002 548<br />
Part No.<br />
Each (€)<br />
L4271275 2810<br />
Part No.<br />
Each (€)<br />
L4285007 121<br />
Diffusion Limiting Caps<br />
(pkg. 5)<br />
Electrical Adapter<br />
Allows for direct connection to wall<br />
outlet. Also acts as a battery charger<br />
for 12 V battery (120/240 V).<br />
Personal Monitoring Pump<br />
Description Size Part No. Each (€)<br />
5-100 mL/min. 110 V N6102351<br />
5-100 mL/min. 220 V N6102197 2028<br />
STS 25 Maintenance Kit<br />
Description Part No. Each (€)<br />
Includes: Rotor Tube Seals (pkg. 50), Filter N6609060 504<br />
Disks (pkg. 25), Diffusion Limiting Caps (pkg. 5),<br />
and Rotor Seal (pkg. 10)<br />
Rotor Filter Disk L4281023 5<br />
Viton O-Ring<br />
For use in diffusion limiting cap<br />
and tube seals. (pkg. 50)<br />
Ozone Precursor Accessories<br />
Alumina PLOT TM Column<br />
50 m x 0.32 mm i.d.<br />
ATD 400 Air Monitoring Trap<br />
Low flow trap packed with carbonaceous<br />
sorbents suitable for ozone precursor<br />
and air toxics monitoring. (pkg. 1)<br />
Methyl Silicone Column<br />
50 m x 0.22 i.d. x 1.0 μm<br />
Nafion Dryer<br />
Particulate Filter Kit<br />
Includes disposable filter and fittings.<br />
For use in the ozone precursor analyzer.<br />
Restrictor Tubing<br />
0.10 mm i.d. uncoated, deactivated,<br />
fused-silica restrictor tubing. For<br />
use in the ozone precursor analyzer.<br />
Part No.<br />
Part No.<br />
Part No.<br />
Each (€)<br />
N6301107 2729<br />
Each (€)<br />
L4275108 332<br />
Part No.<br />
Each (€)<br />
N6301108 1518<br />
Part No.<br />
Each (€)<br />
04974414 1193<br />
Part No.<br />
Each (€)<br />
L4285001 108<br />
Part No.<br />
Each (€)<br />
L4280003 453<br />
Part No.<br />
Each (€)<br />
N6300063 255<br />
Part No.<br />
Each (€)<br />
L4275033 147<br />
Each (€)<br />
N9301355 114<br />
180
Thermal Desorbers<br />
Sample Tubes<br />
Caps for TurboMatrix<br />
Brass Long-Term Storage Caps<br />
Recommended for long-term storage.<br />
Two required per tube. Also requires<br />
Teflon ferrule (L1003015). (pkg. 1)<br />
Combined Teflon Ferrule<br />
For use with 1/4 in. Brass Long-term<br />
Storage Cap (09908851). Two (2)<br />
required per tube. (pkg. 1)<br />
Diffusion Caps – Standard<br />
For passive air sampling to ensure<br />
correct diffusion path length. (pkg. 10)<br />
Diffusion Caps with Membrane<br />
Same as above but with a<br />
silicone membrane. (pkg. 10)<br />
Pen Clips<br />
For stainless steel ATD tubes. (pkg. 10)<br />
PFA Teflon Ferrules for<br />
TurboMatrix Storage End Caps<br />
(pkg. 20)<br />
TurboMatrix Analytical Caps<br />
Required for use on the TurboMatrix<br />
instrument during analysis PTFE Caps<br />
with O-Ring. (pkg. 20)<br />
Replacement Parts for ATD 400<br />
Tube Seal and Tube<br />
Part No.<br />
Each (€)<br />
09908851 4<br />
Part No.<br />
Each (€)<br />
L1003015 7<br />
Part No.<br />
Each (€)<br />
L4070207 164<br />
Part No.<br />
Each (€)<br />
L4070208 588<br />
Part No.<br />
Each (€)<br />
L4071029 31<br />
Part No.<br />
Each (€)<br />
M0413625 218<br />
Part No.<br />
Each (€)<br />
N6200119 280<br />
Description Qty. Part No. Each (€)<br />
1<br />
Packed Sample Tube(s)*<br />
1 Sample Tube(s)*<br />
2<br />
Packing Retaining Gauzes 100 L4071034 114<br />
3<br />
Retaining Springs 50 L4071123 86<br />
4<br />
Chamfer Holder O-Ring 1 04973727 2<br />
5<br />
Tube Seal O-Ring 10 04972383 1<br />
6<br />
Grip Seal O-Ring 50 04970343 15<br />
7<br />
Nozzle Filter Disk 1 L4271159 2<br />
3<br />
* See Sample Tube product listing above.<br />
6<br />
2 2<br />
4 5 1 5 7<br />
Sample Tubes for TurboMatrix<br />
Packed Sample Tubes for TurboMatrix<br />
Pkg. Stainless Steel Glass<br />
Qty. Sorbent Part No. Each (€) Part No. Each (€)<br />
10** Air Toxics Tube N9307001 871 N9307008 871<br />
10** Carbopack B 60/80 N9307002 871 N9307009 871<br />
10** Carbopack B 60/80 N9307000 871 N9307007 871<br />
Carbopack C 60/80<br />
Carbosieve SIII 60/80<br />
10** Carbosieve SIII 60/80 N9307003 871 N9307010 871<br />
10** Chromasorb 106 N9307006 871 N9307013 871<br />
10** NIOSH 2549 tube N9307038 871 N9307037 871<br />
10** Tenax GR 60/80 N9307004 871 N9307011 871<br />
10** Tenax TA 60/80 N9307005 871 N9307012 871<br />
** Shipped with brass long-term storage caps.<br />
Packed Sample Tubes<br />
for TurboMatrix<br />
Empty Sample Tubes with Caps<br />
Glass Lined<br />
Pkg. Stainless Steel Stainless Steel Glass<br />
Qty. Part No. Each (€) Part No. Each (€) Part No. Each (€)<br />
10* M0413597 739 M0413595 340 M0413598 368<br />
50* M0413596 1518<br />
* Shipped with Analytical End Caps (N6200119).<br />
Empty Sample Tubes Without Caps<br />
Pkg. Stainless Steel Glass<br />
Qty. Part No. Each (€) Part No. Each (€)<br />
10 L4270128 224 L4071594 249<br />
100 L4270129 2244<br />
Thermal Desorbers Gas Chromatography<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
181
Thermal Desorbers<br />
Thermal Desorber Supplies<br />
Gas Chromatography Thermal Desorbers<br />
Cold Traps, Fittings,<br />
and Accessories<br />
ATD 400 Air Monitoring Trap<br />
Low flow trap (L4275107) packed with carbonaceous<br />
sorbents suitable for ozone precursor<br />
and air toxics monitoring. (pkg. 1) Part No. Each (€)<br />
ATD Cold Trap Nuts<br />
Two required per trap tube. (pkg. 1)<br />
Cold Trap Tube (packed)<br />
Standard cold trap packed<br />
with CarbopackC.<br />
Cold Trap Tube (Low Flow) Unpacked<br />
Cold trap with reduced bore at one<br />
end. Allows minimum gas flow<br />
during trap desorption. (pkg. 1)<br />
Low Flow Cold Trap<br />
Cold Trap Tube (Tenax TA)<br />
Standard cold trap (L4271106)<br />
packed with Tenax TA 60/80. (pkg. 1)<br />
Cold Trap Tube (Unpacked)<br />
Standard cold trap tube unpacked.<br />
(pkg. 1)<br />
Graphite Ferrule<br />
Ferrule for cold trap. Recommended<br />
for all applications except those using<br />
Mass Spectrometer or ECD. (pkg. 2)<br />
PTFE Ferrule<br />
Ferrules for cold trap. Recommended<br />
for use with Mass Spectrometer<br />
or ECD. (pkg. 10)<br />
Note: New ferrules are required<br />
when trap is changed.<br />
L4275108 332<br />
Part No.<br />
Each (€)<br />
N6200150 317<br />
Part No.<br />
Each (€)<br />
L4275107 248<br />
0.7 mm Sorbents Quartz Wool 2.8 mm<br />
Glass Fiber<br />
Disks<br />
Part No.<br />
Packing Retaining Spring<br />
Part No.<br />
Each (€)<br />
L4275089 126<br />
Part No.<br />
Each (€)<br />
L4275009 59<br />
Each (€)<br />
L4271106 92<br />
Part No.<br />
Each (€)<br />
L4271187 5<br />
Part No.<br />
Each (€)<br />
L4275110 9<br />
Consumables Starter Kit<br />
Thermal Desorber Starter Kit<br />
The starter kit is recommended for all<br />
purchasers who do not already have a<br />
TurboMatrix Thermal Desorber.<br />
Includes:<br />
Description Qty. Part No.<br />
Glass Wool pkg. 1 54120790<br />
Tenax TA 60-80, Mesh – 15 g pkg. 1 04978064<br />
Packing Gauze pkg. 100 L4071034<br />
Retaining Spring pkg. 50 L4071123<br />
Stainless Steel Sample Tubes pkg. 10 M0413595<br />
Glass Sample Tube pkg. 10 M0413598<br />
PTFE Filter Discs, Large pkg. 10 L1003029<br />
PTFE Filter Discs pkg. 10 L1003030<br />
Graphite Ferrules pkg. 2 L4271187<br />
Trap Tube Nuts pkg. 2 L4275009<br />
Trap Tubes pkg. 2 M0410094<br />
Gauze Loading Supplies<br />
Gauze Loading Rig<br />
Correctly positions gauze at both ends of stainless steel<br />
sampling tubes. Highly recommended<br />
when packing sample tubes.<br />
Part No. Each (€)<br />
Replacement Plastic Plunger<br />
for Gauze Loading Device<br />
(pkg. 5)<br />
Interface Cables for ATD 400<br />
Nelson 900 Series<br />
Interface Box Cable<br />
Also transmits BCD.<br />
Ready/Start Cable<br />
Also transmits BCD.<br />
Interface Kit<br />
Thermal Desorber GC Interface Kit<br />
Part No.<br />
Each (€)<br />
M0413541 4845<br />
L4070023 2168<br />
Part No.<br />
Each (€)<br />
L4071151 60<br />
Part No.<br />
Part No.<br />
Each (€)<br />
L4270034 210<br />
Each (€)<br />
L4270032 159<br />
Contains all necessary hardware for connecting the heated<br />
transfer line to either 1/8 in. packed or<br />
capillary columns inside the GC oven. Part No. Each (€)<br />
L4270026 838<br />
182
Thermal Desorbers<br />
Thermal Desorber Supplies<br />
Thermal Desorber to<br />
Agilent 6890 GC Ready Start Cable<br />
Connects a TurboMatrix thermal<br />
desorber to an Agilent 6890<br />
or Agilent 6850 GC.<br />
Manual<br />
TurboMatrix Thermal Desorber<br />
User’s Manual<br />
Miscellaneous Accessories<br />
Backflush Nozzle Accessory<br />
Graphite Vespel Ferrule<br />
1/16 in. x 0.5 mm i.d. For connection<br />
of 0.32 mm i.d. transfer line to ATD.<br />
(pkg. 1)<br />
Internal Standard Injection Accessory<br />
To allow the introduction of a<br />
gaseous internal standard.<br />
Liquid Nitrogen Accessory<br />
For operation of the cold trap to -100 °C.<br />
Note: Requires a pressurized Dewar with a relief valve set at 25 psig<br />
(180 kpa). Dewar must have a 1/4 in. Swagelok TM connection. Also<br />
requires a pressure relief valve set at 50 psig<br />
(350 kpa) in pipe between Dewar and ATD 400. Part No.<br />
Regulator 0-60 psig<br />
The standard 0-30 psig regulator can be replaced with this<br />
0-60 psig regulator to expand the choice of column and<br />
application range. Installation by a<br />
PerkinElmer Service Engineer is<br />
required, but not included.<br />
Part No.<br />
N6101474<br />
Each (€)<br />
300<br />
Valco Graphite Vespel Ferrule<br />
For use on Valco TM valve. 1/16 in. i.d.<br />
(pkg. 1)<br />
Part No.<br />
Each (€)<br />
N6100410 149<br />
Part No.<br />
Each (€)<br />
M0413331 93<br />
Part No.<br />
Each (€)<br />
L4275072 217<br />
Part No.<br />
Each (€)<br />
04972066 7<br />
Part No.<br />
Each (€)<br />
L4270010 4056<br />
Each (€)<br />
L4270009 1836<br />
Part No.<br />
Each (€)<br />
04974018 8<br />
TurboMatrix ATD Sample Carousel<br />
Fifty (50) position tube carousel<br />
for use on the TurboMatrix ATD.<br />
Mobile Seal Assembly<br />
Description Part No. Each (€)<br />
Mobile Seal O-Ring, Viton 009 L1003006 1<br />
Mobile Seal O-Ring, Viton 010 04970343 15<br />
Nozzle Filter Disc (pkg. 1) L4271159 2<br />
Software<br />
TurboMatrix TD/ATD PC Control Software Rev 1.1<br />
Provides full external control of a TurboMatrix thermal<br />
desorber from a personal computer running under Windows ®<br />
95, 98, or NT. Methods and sequences can be generated,<br />
stored, edited, printed, and executed. Functions include<br />
diagnostics, user defined access levels, run reports, and<br />
transfer of vial identification to TotalChrom, allowing<br />
complete data traceability. On-screen<br />
interactive help function is available. Part No. Each (€)<br />
Cable included (M0417035).<br />
M0413559 740<br />
TurboMatrix TD/ATD Remote Control Software<br />
Rev 1.1 (for WIN 2000)<br />
Provides full external control of a TurboMatrix thermal<br />
desorber from a personal computer running under Windows<br />
95, 98, or NT. Methods and sequences can be generated,<br />
stored, edited, printed, and executed. Functions include<br />
diagnostics, user defined access levels, run reports, and<br />
transfer of vial identification to TotalChrom, allowing<br />
complete data traceability. On-screen<br />
interactive help function is available. Part No. Each (€)<br />
Cable included (M0417035).<br />
N6200210 819<br />
Trap Supplies<br />
Part No.<br />
Each (€)<br />
M0413380 234<br />
Description Part No. Each (€)<br />
Ceramic Washer M0415339 9<br />
Cold Trap O-Ring 09200091 30<br />
Heat Conduction Bushing M0410316 8<br />
Filter Disk (pkg. 1) L1003030 47<br />
PTFE filter on either side of cold trap<br />
Packing Disk (pkg. 20) L4271290 16<br />
Glass fiber disk for separating sorbents when<br />
packing cold trap with multiple sorbents<br />
Packing Retaining Spring (pkg. 5) N6301054 29<br />
For low flow trap<br />
Packing Tool L4271203 24<br />
Graphite Ferrule (pkg. 2) L4271187 5<br />
Ferrule for cold trap. Recommended for all<br />
applications except those using Mass Spec or ECD<br />
Gripper Insert Replacement (pkg. 2) M0413645 64<br />
Heated Transfer Line M0413644 1314<br />
Standard length 45 in.<br />
Heated Transfer Line M0413558 1454<br />
Long length 70 in.<br />
Thermal Desorbers Gas Chromatography<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
183
Thermal Desorbers<br />
Thermal Desorber Supplies<br />
Gas Chromatography Thermal Desorbers<br />
Thermal Desorber Empty Trap (pkg. 1) M0413627 238<br />
Thermal Desorber Packed Trap N6200150 317<br />
Trap packed with CarbopackC<br />
TurboMatrix Air Monitoring Trap (pkg. 1) M0413628 317<br />
Trap packed with carbonaceous sorbents suitable<br />
for ozone precurser and air toxics monitoring<br />
TurboMatrix Thermal Desorber Packed Trap (pkg. 1) M0413535 334<br />
Trap packed with Tenax TM TA<br />
PTFE Ferrule L4275110 9<br />
Ferrules for cold trap. Recommended for use with<br />
Mass Spec or ECD. (pkg. 10)*<br />
Trap Filter Disk<br />
PTFE filter on either side of cold trap. (pkg.1) L4271160 5<br />
Trap Heat Conduction Bushing and Ceramic Washer M0410316 8<br />
* New ferrules are required when trap is changed.<br />
TurboMatrix Upgrade Kits<br />
Internal Standard Addition/Tube Dry Purge Add-On Kit<br />
Adds capability to introduce a known quantity of a gaseous<br />
standard into the sample tube prior to desorption to verify<br />
analyte recovery. Standard gas is added to the tube in the<br />
sampling direction, allowing use of tubes packed with<br />
multiple adsorbents.<br />
Note: Requires, but does not include, an Options<br />
Board when added to the entry-level thermal<br />
desorber. Installation by PerkinElmer Service<br />
is required, but not included.<br />
Part No.<br />
M0413555<br />
Each (€)<br />
5300<br />
Liquid Nitrogen Cooling Add-On Kit<br />
For operation of the cold trap to -100 °C. Requires, but does<br />
not include, the options board when added to entry-level<br />
thermal desorber. Requires a pressurized Dewar with a relief<br />
valve set at 25 psig (180 kpa). Dewar must have a 1/4 in.<br />
Swagelok connection. Also requires a pressure relief<br />
valve set at 50 psig (350 kpa) in pipe between Dewar and<br />
TurboMatrix. Installation by<br />
PerkinElmer Service is required,<br />
Part No. Each (€)<br />
but not included.<br />
M0413557 1951<br />
On-Line Sampling Add-On Kit<br />
Adds capability to perform on-line sampling of ambient<br />
air directly to the electrically cooled trap. Overlapping<br />
sampling and GC analysis allows collection of air for<br />
analysis up to 50 minutes of every hour. Includes sample<br />
valve, Nafion drier, dry air purge control, and pump.<br />
Air Toxics trap is installed.<br />
Note: Requires, but does not include, an Options Board when added to<br />
entry-level thermal desorber. Allows thermal desorber to still be used for<br />
tube desorption. Installation by PerkinElmer<br />
Service is required, but not included.<br />
Part No. Each (€)<br />
M0413556 13200<br />
Options Board/BCD Output Board<br />
Required for installation of the following options on an entrylevel<br />
thermal desorber – Internal Standard Addition, On-Line<br />
Sampling, or Liquid Nitrogen Cooling. Also provides output<br />
of BCD information regarding tube position numbers and<br />
provides relay output for timed control of external devices.<br />
Note: This board is included as standard on the<br />
automated thermal desorber. Installation by<br />
PerkinElmer Service is required, but not included.<br />
Part No.<br />
M0413551<br />
Each (€)<br />
988<br />
Thermal Desorber to<br />
Automated Thermal Desorber Upgrade Kit<br />
Includes parts to upgrade an entry-level thermal desorber<br />
to an automated thermal desorber for unattended analysis<br />
of up to 50 samples. Includes BCD output communication<br />
capabilities and timed event relays for timed control of<br />
external devices. Installation<br />
by PerkinElmer Service<br />
Part No. Each (€)<br />
is required, but not included.<br />
M0413553 16600<br />
TurboMatrix Upper Seal Assembly<br />
Description Qty. Part No. Each (€)<br />
Low Temp (< 225 °C), pkg. 10 L1003006 1<br />
Viton ® 009 O-Rings<br />
Low Temp (< 225 °C), pkg. 10 L1003008 5<br />
Viton 011 O-Rings<br />
High Temp (> 225 °C), pkg. 1 M0415361 88<br />
Kalrez ® 011, Large Seal O-Ring<br />
High Temp (> 225 °C), pkg. 1 M0415360 80<br />
Kalrez 009, Small Seal O-Ring<br />
Fixed Upper Seal, Graphite Ferrule 09920593 27<br />
TurboMatrix Thermal Desorber High Temperature Kit<br />
Contains all the necessary hardware for operation of the<br />
valve at temperatures starting at 150 °C up to 300 °C.<br />
Service is required, but not included.<br />
Part No. Each (€)<br />
M0413646 1212<br />
184
PerkinElmer, the undisputed leader in Inductively<br />
Coupled Plasma Mass Spectrometry (ICP-MS), is<br />
the preferred choice for atomic spectroscopy solutions<br />
and services in thousands of laboratories globally.<br />
The PerkinElmer SCIEX ELAN product line of ICP-MS<br />
instruments sets the standard for ICP-MS ultratrace<br />
analysis. Whether you choose instruments based on<br />
classic quadrupole technology or instruments that utilize<br />
patented Dynamic Reaction Cell interference-reduction<br />
technology, every application challenge can be met.<br />
Inductively Coupled Plasma – MS
Inductively Coupled Plasma – MS<br />
QUICK-FIND INDEX Page #<br />
Baffled Cyclonic Spray Chambers 202<br />
Concentric Nebulizers 196<br />
Cooling Systems/Chillers 189<br />
Cyclonic Spray Chambers 203<br />
Demountable Quartz Torches 205<br />
Detectors 190<br />
ELAN Consumables Kits 193<br />
ELAN Software 206<br />
GemClean Crossflow II Nebulizers 197<br />
Injector Support Adapters 195<br />
Injectors 194<br />
Ion Optics 190<br />
Peristaltic Pump Tubing 199<br />
PFA Teflon Nebulizers 196<br />
RF Load Coils 205<br />
Sampler and Skimmer Cones 189<br />
PerkinElmer offers a wide selection of superior quality products designed to work with<br />
your PerkinElmer instruments. Our precision-designed products deliver the peace of<br />
mind that comes from knowing that you’ll get the results you need.<br />
The Quick Find Index to the left will help you find products fast. For your convenience,<br />
products are alphabetized by category, sub-category, and family. There is also a more<br />
complete Alphabetical INDEX on page 429 and a Part Number INDEX on page 407.<br />
Cones<br />
Ion Lenses<br />
Precision designed and manufactured large-orifice Sampler<br />
and Skimmer Cones provide superior, long-term stability and<br />
resist clogging, allowing analysis under both high and low<br />
sample-uptake conditions. PerkinElmer's Sampler and<br />
Skimmer Cones are available in Nickel and Platinum for<br />
all ELAN models.<br />
Page 189<br />
PerkinElmer offers the industry's only Single Ion Lens with<br />
the exclusive SwiftMount TM II Cassette Lens Mount. The plug<br />
and play design makes changing the Ion Lens faster and<br />
simpler than ever before. No tools are required as the<br />
design incorporates a clean capture-and-release concept.<br />
Page 190<br />
Scott Spray Chambers 204<br />
Speciation by Chromatography 207<br />
Standards 209<br />
Nebulizers<br />
PerkinElmer offers a wide selection of nebulizers for use<br />
with your ELAN. From our exclusive GemClean design to<br />
standard concentric, PFA Teflon and ultrasonic nebulizers,<br />
you can choose the option that best fits your instrument<br />
and your analysis.<br />
Page 196<br />
Spray Chambers<br />
The spray chamber is responsible for filtering the sample<br />
mist to permit the appropriate droplet size distribution to<br />
reach the plasma. PerkinElmer offers a large selection of<br />
Baffled Cyclonic, Cyclonic and Scott models. Cyclonic and<br />
Baffled Cyclonic models are available in Standard, O-Ring<br />
Free and Water-Cooled versions. Scott models are available<br />
in PFA Teflon, Water-Cooled and Ryton versions.<br />
Page 202
The ELAN Family Sets the Standard<br />
for ICP-MS Ultratrace Analysis<br />
For over 20 years, PerkinElmer and SCIEX<br />
have partnered to develop and distribute the<br />
most innovative and powerful ICP-MS systems.<br />
There are over 2500 ICP-MS systems installed in industries ranging from<br />
environmental and clinical to semiconductor, geochemical and metallurgical,<br />
making PerkinElmer SCIEX the industry leader in ICP-MS.<br />
As the undisputed market leader in ICP-MS, PerkinElmer SCIEX continues<br />
to provide innovative solutions to evolving customer needs:<br />
■ NEW quick-change torch cassette –<br />
changing the torch components is a very<br />
simple process – no tools are required<br />
■ NEW SwiftMount II – the snap-in-place<br />
design makes lens removal or installation<br />
a two-finger approach<br />
■ NEW oil-drain system – changing the oil<br />
in the mechanical vacuum pumps is now<br />
easier and cleaner, using the integrated<br />
valve and thread-on valve extension<br />
■ NEW improved detector lifetime – new<br />
detector electronics enable operation at<br />
lower detector voltages, thereby extending<br />
detector lifetime<br />
ELAN 9000<br />
ELAN ® 9000<br />
Optimizes routine ultratrace analysis<br />
The ELAN 9000 ICP-MS instrument is<br />
perfect for laboratories looking to take<br />
advantage of the powers of detection<br />
of an ICP-MS. It incorporates proven<br />
ICP-MS technology based on 40 years of<br />
innovation and listening to our customers.<br />
The ELAN 9000 simplifies ICP-MS by<br />
providing an easy-to-use, easy-to-maintain<br />
tool for routine ultratrace level analysis.<br />
It is ideal for environmental, clinical,<br />
geochemical and general testing<br />
laboratories with moderate to heavy<br />
loads of ultratrace-level samples.<br />
The proven design of the ELAN 9000<br />
ICP-MS ensures accuracy, improves<br />
method development and consistently<br />
delivers the correct answer, reducing<br />
rework and improving productivity.<br />
Design enhancements provide increased<br />
reliability and reduced cost of ownership,<br />
when compared with other ICP-MS systems.<br />
ELAN DRC-e<br />
Expanding the capabilities of ICP-MS<br />
When your applications extend beyond the<br />
capabilities of conventional quadrupole<br />
ICP-MS, you need the power of the<br />
innovative ELAN DRC-e. The DRC-e<br />
brings the interference-eliminating power<br />
of patented Dynamic Reaction Cell TM<br />
(DRC) technology and performanceenhancing<br />
Axial Field TM Technology (AFT)<br />
to the industry-proven ELAN ICP-MS<br />
system. The result is uncompromised<br />
sensitivity and performance in a robust<br />
system designed for routine laboratories.<br />
Combined with a robust HF-resistant<br />
sample introduction system and the<br />
purpose-designed productivity enhancing<br />
features of the ELAN ICP-MS system, the<br />
maintenance-free Dynamic Reaction Cell<br />
provides a system with uncompromised<br />
performance that is rugged, reliable and<br />
easy-to-use — a must for today’s highthroughput<br />
production environments.<br />
ELAN DRC II<br />
The ultimate in ICP-MS performance<br />
When your applications extend beyond<br />
the capabilities of conventional ICP-MS,<br />
you need the power of the ELAN DRC II.<br />
The ELAN DRC II combines the power of<br />
patented Dynamic Reaction Cell (DRC)<br />
technology, performance-enhancing Axial<br />
Field Technology (AFT) and a highperformance<br />
sample introduction system<br />
with the ability to run any reaction gas.<br />
The result is the ultimate analytical tool,<br />
providing uncompromised sensitivity<br />
and performance in all matrices for the<br />
world’s most difficult applications.<br />
Unlike collision-cell, high-resolution<br />
or cool-plasma systems, the ELAN<br />
DRC II completely eliminates polyatomic<br />
interferences, minimizing background<br />
equivalent concentrations, while<br />
maintaining analyte sensitivity,<br />
providing ultratrace-level detection<br />
limits in virtually any sample.<br />
187
Autosampler and Flow Injection Supplies<br />
Sample Trays, Probes, Tubing, and Accessories<br />
Inductively Coupled Plasma – MS Autosampler and Flow Injection<br />
Autosampler Supplies and<br />
Accessories for ICP-MS<br />
Please see pages 8-10 for our full selection of Sample Trays, Sample Vessels,<br />
Probes, Tubing, and Accessories.<br />
FIAS-400MS Supplies<br />
and Accessories<br />
Please see pages 21-28 for our full selection of Cells, Connectors, Tubing<br />
Valves, and Accessories.<br />
Flow Injection Analysis Upgrade Kit<br />
For use with ELAN 9000/6X00/DRC instruments. It enables<br />
the standard FIAS-400 and FIAS-200 systems to be used for<br />
ICP-MS. Includes ELAN read cable and<br />
the FIAS-400MS hardware manual.<br />
Part No. Each (€)<br />
N8120119 293<br />
ELAN 9000/6X00 FIAS Vapor Adapter Kit<br />
This kit includes all the tubing and connections to connect<br />
the gas-liquid separator to the torch, when doing hydride<br />
generation work. The Vapor<br />
Adapter Kit is included with<br />
the FIAS-400MS system.<br />
Part No.<br />
B0505540<br />
Each (€)<br />
580<br />
Preconcentration Connector Kit<br />
For use with the FIAS-400MS flow injection system. Includes<br />
special connectors and tubing for preconcentration with<br />
ICP-MS. Additionally required, but not included: C18 or<br />
XAD-8 Preconcentration Columns and<br />
Five-port Sampling Valve. Service<br />
installation is recommended.<br />
Part No.<br />
B0508593<br />
Each (€)<br />
1161<br />
Preconcentration Columns<br />
For use with FIA Preconcentration.<br />
Description Qty. Part No. Each (€)<br />
C18 10 B0504047 689<br />
XAD-8 10 B0504048 689<br />
Gilson 222 Accessories<br />
Adapter Plate For Gilson Racks<br />
Required to adapt Gilson 222<br />
style racks to the AS-93plus.<br />
Gilson 222 Teflon Sampling Probe Kit<br />
Includes 1.25 mm i.d. Teflon-lined<br />
sample probe with a bored-out holder.<br />
UltraClean Sampling<br />
Probes and Accessories<br />
UltraClean Sampling Probes<br />
UltraClean Probe<br />
For use with the AS-9x<br />
Autosampler. For ultratrace<br />
analysis with<br />
PFA-ST Concentric<br />
Nebulizer (N8122192).<br />
Requires CTFE Union<br />
(N8122355) to connect<br />
to PFA-ST nebulizer.<br />
Dimension Flow Rate Part No. Each (€)<br />
0.5 mm i.d. 400 μL/min. N8122361 230<br />
0.25 mm i.d. 100 μL/min. N8122360 230<br />
CTFE Union<br />
Part No. N8122360<br />
Part No.<br />
Necessary to connect UltraClean Autosampler Probe<br />
(N8122360 and N8122361) with PFA-ST Teflon<br />
Concentric Nebulizer (N8122192).<br />
Part No.<br />
Each (€)<br />
B3140647 48<br />
Part No.<br />
Each (€)<br />
N8122170 268<br />
Each (€)<br />
N8122355 38<br />
188
Mass Spectrometer Hardware<br />
Cones and Cooling Systems<br />
Cones and Accessories<br />
Precision designed and manufactured large-orifice Sampler<br />
and Skimmer Cones provide superior, long-term stability<br />
and resist clogging, allowing analysis under both high and<br />
low sample-uptake conditions.<br />
Nickel Sampler<br />
Part No. WE021140<br />
Nickel Sampler and Skimmer Cones<br />
ELAN Model Type Part No. Each (€)<br />
9000/6X00/DRC Sampler WE021140 542<br />
9000/6X00/DRC Skimmer WE021137 689<br />
5000 Sampler WE013087 363<br />
5000 Skimmer N8122000 536<br />
Platinum Sampler<br />
Part No. WE027802<br />
Nickel Skimmer<br />
Part No. WE021137<br />
Platinum Skimmer<br />
Part No. WE027803<br />
Platinum Sampler and Skimmer Cones<br />
ELAN Model Type Part No. Each (€)<br />
9000/6X00/DRC Sampler WE027802 1722<br />
9000/6X00/DRC Skimmer WE027803 1977<br />
5000 Sampler N8122025 2245<br />
5000 Skimmer N8122035 4043<br />
Sampler and Skimmer Cone O-Rings<br />
ELAN Model Type Qty. Part No. Each (€)<br />
9000/6X00/DRC Sampler 5 N8120511 14<br />
9000/6X00/DRC Skimmer 5 N8120512 8<br />
5000 Sampler 1 N8122003 9<br />
5000 Sampler 20 N8120114 147<br />
5000 Skimmer 1 N8122002 9<br />
5000 Skimmer 20 N8120113 147<br />
Cone Removal Tool<br />
ELAN Model Part No. Each (€)<br />
9000/6X00/DRC WE017142 351<br />
5000 N8122040 210<br />
Sampler Cone Aluminum Gasket<br />
One aluminum gasket for<br />
ELAN 5000 Sampler Cones.<br />
Cooling Systems<br />
Chillers/Recirculating Water Cooling Systems<br />
Chillers for the ELAN 5000/6X00/DRC systems. Designed<br />
to handle process temperatures from -10° to 40 °C (14° to<br />
104 °F), they feature convenient “one-touch” temperature<br />
control and bright LED readouts which can be easily read,<br />
even from across the room –<br />
and let you check temperature<br />
set point and fluid flow rate<br />
and/or pressure with just a<br />
quick touch.<br />
For added operational safety,<br />
they also feature audible<br />
and visual alarms that alert<br />
you instantly when operating<br />
parameters – such as fluid<br />
temperature, flow rate,<br />
fluid pressure, and ambient<br />
temperature – exceed preset<br />
limits. There are even useradjustable<br />
high and low<br />
temperature limits to help<br />
prevent unauthorized set<br />
point changes plus built-in<br />
safeties to alert you to low<br />
fluid levels and thermal runaway.<br />
Requires the use of ELAN Coolant Fluid (WE016558).<br />
Power<br />
Requirement Operating Temp Flow Rate Part No. Each (€)<br />
208 - 230 V, -15° to 40 °C 60 psi: N0772026 4029<br />
60 Hz, 8 A 4.3 gpm/<br />
16.3 Lpm<br />
240 V, -15° to 40 °C 60 psi: N0772025 4029<br />
50 Hz, 8.5 A 4.3 gpm/<br />
16.3 Lpm<br />
Heat Exchanger System<br />
Part No.<br />
Cooling systems for the ELAN 9000/DRC II/e systems.<br />
Air cooled recirculator without refrigeration. Not to be<br />
placed in areas with temperatures above 30 °C (86 °F).<br />
Requires the use of ELAN Coolant Fluid (WE016558).<br />
Each (€)<br />
WE012989 16<br />
Power Requirement Part No. Each (€)<br />
120 V, 60 Hz N8122248 2265<br />
220/250 V, 50/60 Hz N8122247 2300<br />
Mass Spectrometer Hardware Inductively Coupled Plasma – MS<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
189
Mass Spectrometer Hardware<br />
Cooling Systems, Detectors, and Ion Optics<br />
Inductively Coupled Plasma – MS Mass Spectrometer Hardware<br />
Heavy Organics Chiller<br />
For all ELANs. Refrigerated recirculating system capable of<br />
maintaining the heavy organic sample introduction system<br />
(N8122132) at -20 °C.<br />
Power Requirements Part No. Each (€)<br />
240 V, 50 Hz N8122193 4591<br />
120 V, 60 Hz N8122194 4591<br />
ELAN Coolant Fluid<br />
1 liter bottle. It is essential that this chiller coolant be used<br />
with ELAN 9000/6X00/DRC series<br />
instruments. Also suitable<br />
for organics chillers.<br />
Part No.<br />
WE016558<br />
Each (€)<br />
29<br />
Detectors<br />
SimulScan Dual-Stage Detector<br />
The dual-stage detector is an integral part of the ELAN<br />
SimulScan TM system. It measures both high- and low-level<br />
analytes simultaneously. This conserves valuable or limited<br />
samples, eliminates the need to perform time-consuming<br />
sample dilutions, and allows you to quickly characterize<br />
unknown samples. Designed specifically for use with the<br />
ELAN 9000/6X00/DRCs.<br />
Service installation is<br />
Part No. Each (€)<br />
required, but not included.<br />
N8125001 3469<br />
Detector Electronics Upgrade Kit<br />
For ELAN 9000/6X00/DRCs manufactured before April 2005.<br />
Boosts detector life at least 20%.<br />
Service installation required,<br />
but not included.<br />
Part No.<br />
W1013195<br />
Each (€)<br />
126<br />
Ion Optics<br />
PerkinElmer offers the<br />
industry’s only Single<br />
Ion Lens with the<br />
exclusive SwiftMount TM<br />
II Cassette Lens Mount.<br />
The plug and play<br />
design makes changing<br />
the Ion Lens faster and<br />
simpler than ever<br />
before. No tools are<br />
required as the design<br />
incorporates a clean<br />
capture-and-release<br />
concept. In fact, the<br />
process takes less than<br />
60 seconds, while competitive lens systems that have 30<br />
to 40 pieces are very difficult to clean and reassemble.<br />
And since the lens is only one piece, there is no need to<br />
restabilize the system after cleaning.<br />
Cassette Ion Lens Upgrade Kit<br />
Slide and Click demountable lens assembly for all ELANs<br />
manufactured before April 2005.<br />
Includes all mounting hardware,<br />
ShadowStop TM , and a Series II Lens.<br />
Part No.<br />
W1017871<br />
Each (€)<br />
1268<br />
Series II Ion Lens<br />
Contains a demountable single ion replacement lens for<br />
either the Series II or Cassette Lens Assembly for ELAN<br />
9000/6X00/DRCs manufactured<br />
between January 1998 and April 2005. Part No. Each (€)<br />
Ion Lens<br />
Replacement ion lens for use with early model ELAN 6000s<br />
manufactured before January 1998 that do not have the<br />
Series II lens upgrade. In addition,<br />
some instruments may require<br />
Feed-thru Connector (WE016510).<br />
Part No.<br />
WE014777<br />
Each (€)<br />
172<br />
Cassette Lens ShadowStop<br />
The PerkinElmer SCIEX<br />
patented ShadowStop prevents<br />
photons and un-ionized matrix<br />
constituents from entering the<br />
quadrupole, lowering system<br />
background, and eliminating drift.<br />
This innovation also enhances<br />
ease-of-use because the<br />
ShadowStop is grounded,<br />
making it a passive part of the<br />
ion optic design.<br />
Replacement ShadowStop for use with the Cassette Lens<br />
Mount. For use with ELAN 9000/DRCs<br />
manufactured after April 2005.<br />
Part No. Each (€)<br />
Series II ShadowStop<br />
Replacement ShadowStop for use with ELAN 9000/6100/<br />
DRCs and the Series II Lens Assembly on all ELAN 6000s<br />
manufactured between January 1998<br />
and April 2005.<br />
Part No. Each (€)<br />
Series II Lens Removal Tool<br />
Flexible shaft driver with<br />
removable 2 mm Hex Ball Bit.<br />
2 mm Hex Ball Bit<br />
For use with Series II Lens<br />
Removal Tool (W1010620).<br />
WE018034 319<br />
W1013361 70<br />
WE029011 208<br />
Part No.<br />
Each (€)<br />
W1010620 62<br />
Part No.<br />
Each (€)<br />
W1010598 11<br />
190
Mass Spectrometer Hardware<br />
Mass Flow Controllers<br />
Mass Flow Controllers<br />
Multichannel Mass Flow Controller<br />
For the ELAN 9000/6X00 series of instruments. 3-channel<br />
Mass Flow Controller (MFC) assembly for computer control<br />
of the Plasma, Auxiliary, and Nebulizer gas flows on the<br />
ELAN 6X00/9000. Not for ELAN DRCs. Contains control<br />
unit, software, cabling, tubing, and 2 MFC heads. The internal<br />
MFC from the ELAN is used as the nebulizer channel.<br />
(For instruments manufactured prior to January 1996, the<br />
ELAN 5000 MFC Head, Part No. N8122074 is also required.)<br />
A fourth channel is also available as an extra option.<br />
The computer-controlled fourth channel can be 2 L/min.<br />
(WE018079) for use as a plasma make-up gas when using<br />
certain sampling accessories. Requires software v2.1 or<br />
greater. Service installation is required, but not included.<br />
Power Requirement Part No. Each (€)<br />
110 V, 60 Hz WE018076 16500<br />
220 V, 50 Hz WE018355 17300<br />
Fourth Channel 2 L/min. MFC Option<br />
For the ELAN 9000/6X00 series of instruments. 0-2 L/min.<br />
Mass Flow Controller for use as a plasma make-up gas when<br />
using certain sampling accessories. Not suitable for use with<br />
oxygen. Requires the Multichannel Mass Flow Controller<br />
(WE018076 or WE018355).<br />
Part No. Each (€)<br />
Secondary Nebulizer Gas Mass Flow<br />
Controller Assembly<br />
WE018079 6610<br />
For the ELAN 9000/6X00 series. Free-standing singlechannel<br />
0-2 L/min. Mass Flow Controller for the secondary<br />
(make-up) nebulizer gas flow used with certain sampling<br />
accessories, e.g., low sample uptake<br />
nebulizers. Not suitable for use with<br />
oxygen. Not computer-controlled.<br />
Part No.<br />
N8120503<br />
Each (€)<br />
6100<br />
Mass Flow Controller Assembly<br />
for Organic Sampling System<br />
For the ELAN 9000/6X00 series. A free-standing 0-200<br />
mL/min. Mass Flow Controller for control of the oxygen<br />
flow when using the organic sampling<br />
system. Not computer controlled. Part No. Each (€)<br />
N8120161 6400<br />
Plasma/Aux Gas Mass Flow Controller Upgrade Kit<br />
For the ELAN DRC II and DRC-e. Kit includes two 0-2 L/min.<br />
and 0-20 L/min. Mass Flow Controllers for the Plasma and<br />
Aux gases. Service installation<br />
is required, but not included.<br />
Part No. Each (€)<br />
WE028426 6800<br />
Make-up Gas Mass Flow Controller Upgrade Kit<br />
For the ELAN DRC II and DRC-e. Kit includes one 0-2 L/min.<br />
Mass Flow Controller for the computer controlled addition of<br />
a make-up gas into the plasma. Not for<br />
use with oxygen. Service installation is<br />
required, but not included.<br />
Part No.<br />
WE028427<br />
Each (€)<br />
2571<br />
Oxygen Gas Mass Flow Controller Upgrade Kit<br />
For the ELAN DRC II and DRC-e. Kit includes one 0-200<br />
mL/min. Mass Flow Controller for the computer controlled<br />
addition of oxygen gas into the plasma.<br />
For analyzing organic solvents. Service<br />
installation is required, but not included.<br />
Part No.<br />
WE028428<br />
Each (€)<br />
2571<br />
Nebulizer Gas Mass Flow Controller Upgrade Kit<br />
For ELAN 6000. A built-in nebulizer gas, 0-2 L/min.<br />
Mass Flow Controller Kit. This upgrade kit is available<br />
for instruments shipped before<br />
January 1996. Service installation<br />
is required, but not included.<br />
Part No.<br />
WE015772<br />
Each (€)<br />
4910<br />
Mass Spectrometer Hardware Inductively Coupled Plasma – MS<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
191
Mass Spectrometer Hardware<br />
Reaction Gas Accessories<br />
Inductively Coupled Plasma – MS Mass Spectrometer Hardware<br />
DRC Gas Cabinets and Upgrade Kits<br />
DRC Gas Safety Cabinets<br />
For Semiconductor use in North America. Complete Article<br />
80 compliant gas safety cabinet and delivery system for<br />
DRC instruments. 110 V, 60 Hz.<br />
Channels Gas Part No. Each (€)<br />
Single Ammonia only (NH 3 ) N8122385 14000<br />
Dual Ammonia and Oxygen (NH 3 and O 2 ) N8122387 19100<br />
Dual Ammonia and Methane (NH 3 and CH 4 ) N8122388 19100<br />
Axial Field Technology Upgrade Kit<br />
for ELAN DRC to a DRC plus<br />
Includes all hardware necessary to upgrade an ELAN DRC<br />
to a DRC plus . Service installation<br />
required, but not included.<br />
Part No. Each (€)<br />
ELAN DRC-e to DRC II Upgrade Kit<br />
Remote Roughing Pump Kit<br />
Allows placement of the roughing pumps up to 3 meters<br />
away from ELAN DRCs. Service<br />
installation required, but not included. Part No. Each (€)<br />
Stainless Steel Second Reaction<br />
Gas Pneumatics (without getter)<br />
WE027567 9900<br />
Complete upgrade of a DRC-e to a DRC II. Includes<br />
ammonia regulator and solutions. Service installation<br />
required, but not included.<br />
Part No. Each (€)<br />
Second Reaction Gas Pneumatics<br />
W1012771 35700<br />
WE023935 3686<br />
Allows the use of a second Reaction Gas on DRC IIs, which<br />
have stainless steel gas lines and VCR fittings (manufactured<br />
after January 2004). Cannot be used on instruments with<br />
Teflon reaction gas lines (manufactured before January 2004).<br />
Recommended for reaction gases containing oxygen. Includes<br />
precision 0-3 mL/min. metal Mass Flow Controller, orbitally<br />
welded stainless steel tubing<br />
with VCR fittings and valving. Service Part No. Each (€)<br />
installation required, but not included.<br />
W1008680 4999<br />
Second Reaction Gas Pneumatics (without getter)<br />
Allows the use of a second Reaction Gas with ELAN DRC/<br />
DRC plus /DRC-e and DRC IIs which do not have stainless<br />
steel gas lines (manufactured before January 2004).<br />
Recommended for reaction gases containing oxygen.<br />
Includes precision 0-3 mL/min. Mass Flow Controller and<br />
valving. Service installation required, but not included.<br />
ELAN Model Part No. Each (€)<br />
DRC-e/DRC II (Manufactured before January 2004) WE028439 4999<br />
DRC/DRC plus WE024354 4999<br />
Ammonia Reaction Gas Channel<br />
Allows the use of ammonia as a reaction gas with the ELAN<br />
DRC-e. Requires Corrosive Purge Turbomolecular Pump Kit<br />
(WE029013). Includes precision 0-3 mL/min. Mass Flow<br />
Controller, getter, valving, electronics<br />
and foreline trap. Service installation<br />
required, but not included.<br />
Part No.<br />
W1006057<br />
Each (€)<br />
34300<br />
Getter Regeneration Kit for ELAN DRCs<br />
Temperature controller, gas regulator, and<br />
tubing which allows regeneration of the<br />
Reaction Gas getter on DRC instruments.<br />
Vacuum Pumps and Accessories<br />
Corrosive Purge Turbomolecular Pump Kit<br />
for ELAN 9000 and DRC-e<br />
Protects the turbopump from damage caused by the<br />
analysis of samples containing high concentrations of<br />
phosphoric acid and the use of ammonia reaction gas.<br />
Service installation is required, but not included.<br />
ELAN Model Part No. Each (€)<br />
9000/DRC-e WE029013 7100<br />
6X00 WE017603 23600<br />
Vacuum Pump Oil<br />
For use with Roughing Pumps. One gallon (3.8 liters).<br />
Pump Model Part No. Each (€)<br />
Leybold N8122004 293<br />
Varian N8122308 86<br />
High Vacuum Silicon Grease<br />
For lubrication of ELAN 9000/6X00/<br />
5000/DRCs vacuum system O-rings.<br />
Part No.<br />
Each (€)<br />
WE023257 2500<br />
Part No.<br />
Each (€)<br />
09905147 34<br />
192
Sample Introduction<br />
Consumables Kits and Graphite Furnace Supplies<br />
ELAN Consumables Kits<br />
Consumables Kit for ELAN DRC-e/9000/6X00<br />
Typical one year’s supply of consumables for ELAN<br />
DRC-e/9000/6X00. Consists of the following parts:<br />
Consumables Kit for ELAN DRC II<br />
Typical one year’s supply of consumables for ELAN DRC II.<br />
Consists of the following parts:<br />
Descriptions Kit Qty. Part No. Each (€)<br />
Demountable Quartz Torch 2 N8122006 287<br />
RF Coil Assembly 1 WE021816 312<br />
Alumina Injectors, 2.0 mm i.d. 2 N8126041 198<br />
Cross-Flow II Replacement GemTips 1 N8120515 113<br />
Injector Support Adapter 1 N8120116 79<br />
(Assembled with O-Rings)<br />
Internal Injector Support Adapter O-Ring 1 09210011 1<br />
External Injector Support Adapter O-Ring 2 09210012 1<br />
Injector Support Adapter O-Ring 1 N8122010 3<br />
Drain Tubing for Peristaltic Pump 1 N8122012 37<br />
(12/pack)<br />
Peristaltic Pump Sample Tubing 4 09908587 59<br />
(12/pack)<br />
Capillary Tubing (10 feet/pack) 2 09908265 29<br />
Drain Tubing Adapter Connectors 4 09920379 1<br />
Sampler Cone O-Rings 5 WE012687 2<br />
Skimmer Cone O-Rings 5 09902218 1<br />
Nickel Sampler Cones 3 WE021140 542<br />
Nickel Skimmer Cones 3 WE021137 689<br />
Rear Air Filter, Pump Side 1 WE021074 12<br />
Rear Air Filter, ICP Side 1 WE022567 11<br />
Cartridge Water Filter 1 09904846 43<br />
Vacuum Pump Oil, 1 Gallon (Varian) 1 N8122308 86<br />
SimulScan Dual-Stage Detector 1 N8125001 3469<br />
Argon Regulator Filter 1 N8125006 22<br />
Series II Ion Lens 1 WE018034 319<br />
HGA – 600MS Supplies<br />
Part No.<br />
Each (€)<br />
N8120509 7900<br />
Graphite Consumable Parts for the HGA-600MS<br />
Components Part No. Each (€)<br />
1A<br />
Short Contact Cylinders (pkg. 5) B0105111 194<br />
Left-hand electrical contacts<br />
1B<br />
Cooling Rings (pkg. 5) B0155481 191<br />
1C<br />
Probe Tips (pkg. 10) B0508371 146<br />
Threaded tips for sealing the graphite<br />
furnace during vaporization<br />
1D<br />
Tip Holders (pkg. 5) B0508373 87<br />
1E<br />
Long Contact Cylinders (pkg. 5) B0139997 243<br />
Right-hand electrical contacts<br />
1F<br />
Extractor Tubes (pkg. 5) B0508374 179<br />
Sampling valve inserts<br />
1G<br />
Pyrolytically Coated Tubes (pkg. 10) B0135653 403<br />
1 Pyrolytically Coated Tubes (pkg. 50) B0091504 1808<br />
Descriptions Kit Qty. Part No. Each (€)<br />
Demountable Quartz Torch 2 N8122006 287<br />
O-Ring Kit for Injector Support Adapter 3 N8120100 4<br />
RF Coil Assembly 1 WE021816 312<br />
Quartz Ball Joint Injectors, 2.0 mm i.d. 2 WE023948 670<br />
Ball Joint Injector Support Adapter 1 WE023951 168<br />
Internal Injector Support Adapter O-Ring 3 09210011 1<br />
Drain Tubing Adapter Connectors 2 N8122012 37<br />
(12/pack)<br />
Peristaltic Pump Sample Tubing 4 09908587 59<br />
(12/pack)<br />
Capillary Tubing (10 feet/pack) 2 09908265 29<br />
Drain Tubing Adapter Connectors 4 09920379 1<br />
Sampler Cone O-Rings 1 N8120511 14<br />
Skimmer Cone O-Rings 1 N8120512 8<br />
Platinum Sampler Cone 1 WE027802 1722<br />
Platinum Skimmer Cone 1 WE027803 1977<br />
Rear Air Filter, ICP Side 1 WE022567 11<br />
Rear Air Filter, Pump Side 1 WE021074 12<br />
Vacuum Pump Oil, 1 Gallon (Varian) 1 N8122308 86<br />
SimulScan Dual-Stage Detector 1 N8125001 3469<br />
Argon Regulator Filter 1 N8125006 22<br />
Series II Ion Lens 1 WE018034 319<br />
Liquid Connector for Concentric Nebulizers 1 WE024372 110<br />
Teflon Sample Capillary 6 WE024375 1<br />
for Concentric Nebulizers<br />
A<br />
B<br />
D<br />
C<br />
G<br />
Part No.<br />
Each (€)<br />
N8120542 10400<br />
E<br />
F<br />
Sample Introduction Inductively Coupled Plasma – MS<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
193
Sample Introduction<br />
Injectors and Adapters<br />
Inductively Coupled Plasma – MS Sample Introduction<br />
Alumina Injectors<br />
Alumina Injectors are compatible with Twist Type and<br />
Cassette Torch Mounts. They are vacuum baked to<br />
reduce contamination.<br />
Alumina Injector, 2.0 mm i.d.<br />
Shipped standard with the ELAN DRC-e/9000/6X00/5000/<br />
500. For use with HF-resistant (Ryton ® ) sample introduction<br />
system. Standard injector for aqueous<br />
solutions and less volatile<br />
organic solvents.<br />
Part No.<br />
N8126041<br />
Each (€)<br />
198<br />
Alumina Injector Tube, 1.5 mm i.d.<br />
For the ELAN DRC-e/9000/6X00/5000/500. For reduced<br />
sample loading with HF-resistant<br />
(Ryton) sample introduction system.<br />
Part No. Each (€)<br />
N8126040 198<br />
Alumina Injector Tube, 0.85 mm i.d.<br />
For the ELAN DRC-e/9000/6X00/5000/500. Recommended<br />
for use with volatile organic solutions<br />
on the HF-resistant (Ryton) sample<br />
introduction system.<br />
Part No.<br />
N8126039<br />
Each (€)<br />
198<br />
PFA Injector Assemblies<br />
PFA/Quartz Twist Type Torch<br />
Injector Assembly, 1.5 mm i.d.<br />
For use with instruments that have the twist type torch<br />
mount (available on ELAN models manufactured before<br />
April 2005). An economical solution for many non-HF<br />
applications. For direct analysis of organic solvents. 1.5 mm<br />
i.d. Quartz Injector permanently mounted in PFA support.<br />
Use to reduce solvent loading with<br />
PFA Teflon sample introduction<br />
Part No. Each (€)<br />
system and peltier organics kit.<br />
N8122394 350<br />
PFA/Quartz Cassette Torch<br />
Injector Assembly, 1.5 mm i.d.<br />
For use with instruments that have the cassette torch mount<br />
(available on ELAN models manufactured after April 2005).<br />
An economical solution for many non-HF applications.<br />
For direct analysis of organic solvents. 1.5 mm i.d. Quartz<br />
Injector permanently mounted in PFA support. Use to<br />
reduce solvent loading with PFA<br />
Part No. Each (€)<br />
Teflon sample introduction system<br />
and peltier organics kit.<br />
N8122413 350<br />
PFA/Sapphire Twist Type Torch<br />
Injector Assembly, 1.8 mm i.d.<br />
For use with instruments that have the twist type torch<br />
mount (available on ELAN models manufactured before<br />
April 2005). This HF-resistant injector is ideal for most<br />
high purity and low background applications. 1.8 mm i.d.<br />
sapphire injector permanently mounted<br />
in PFA support. For use with PFA Part No. Each (€)<br />
sample introduction system.<br />
N8122358 740<br />
PFA/Sapphire Cassette Torch<br />
Injector Assembly, 1.8 mm i.d.<br />
For use with instruments that have the cassette torch mount<br />
(available on ELAN models manufactured after April 2005).<br />
This HF-resistant injector is ideal for most high purity and<br />
low background applications. 1.8 mm i.d. sapphire injector<br />
permanently mounted in PFA<br />
support. For use with PFA sample Part No. Each (€)<br />
introduction system.<br />
N8122411 740<br />
PFA/Platinum Twist Type Torch Injector Assembly Part No. N8122359<br />
PFA/Platinum Twist Type Torch<br />
Injector Assembly, 2.0 mm i.d.<br />
For use with instruments that have the twist type torch mount<br />
(available on ELAN models manufactured before April 2005).<br />
This HF-resistant injector is recommended for improved<br />
performance for sub to low ppt Al determinations. 2.0 mm<br />
i.d. platinum injector permanently mounted in PFA support.<br />
For use with PFA Teflon sample<br />
introduction system. Not for use<br />
Part No. Each (€)<br />
with hydrogen peroxide.<br />
N8122359 2296<br />
PFA/Platinum Cassette Torch Injector Assembly. Part No. N8122412<br />
PFA/Platinum Cassette Torch<br />
Injector Assembly, 2.0 mm i.d.<br />
For use with instruments that have the cassette torch mount<br />
(available on ELAN models manufactured after April 2005).<br />
2.0 mm i.d. platinum injector permanently mounted in PFA<br />
support. For use with PFA Teflon<br />
sample introduction system. Not<br />
for use with hydrogen peroxide.<br />
Part No.<br />
N8122412<br />
Each (€)<br />
2295<br />
194
Sample Introduction<br />
Injectors and Adapters<br />
Quartz Injectors<br />
Injector Support Adapters<br />
Quartz Injectors are compatible with Twist Type and<br />
CassetteTorch Mounts.<br />
Quartz Ball Joint Injectors<br />
For ELAN DRC/DRC plus /DRC II. For use with pass-through Ball<br />
Joint Injector Support Adapters (WE023951 or W1012406).<br />
Description Recommended Use Part No. Each (€)<br />
2.0 mm i.d. General Purpose WE023948 670<br />
1.5 mm i.d.* Organics WE027005 638<br />
0.85 mm i.d.* Volatile Organics WE027030 638<br />
* For reduced sample loading.<br />
Quartz Injectors<br />
For the ELAN DRC-e/9000/6X00/5000 when using the<br />
HF-Resistant Sample Introduction System (WE024782).<br />
Description Recommended Use Part No. Each (€)<br />
2.0 mm i.d. Clinical Samples N8125029 191<br />
1.6 mm i.d. Organic Solvents 00473292 134<br />
1.2 mm i.d. Organic Solvents N0681631 159<br />
Sapphire Injector<br />
Sapphire Injector Tube, 2.0 mm i.d.<br />
For the ELAN DRC-e/9000/6X00/5000. Demountable<br />
injector for use with the HF-resistant (Ryton) sample<br />
introduction system. Not for use with<br />
PFA sample introduction system. Part No.<br />
Each (€)<br />
N0695495 995<br />
Ball Joint Twist Type Torch Injector Support Adapter<br />
For ELAN DRC/DRC plus /DRC II. Pass-through design for use<br />
with ball joint injectors. For use with twist type torch mounts<br />
(manufactured before April 2005).<br />
Part No. Each (€)<br />
Ball Joint Cassette Torch Injector Support Adapter<br />
Twist Type Torch Injector Support Adapter<br />
Twist Type Torch Injector Support Adapter<br />
(Assembled with O-Rings)<br />
For the ELAN 9000/6X00/5000/DRC-e. For use with the<br />
Corrosion-Resistant Torch and the<br />
Ryton Scott Spray Chamber.<br />
Part No. Each (€)<br />
Cassette Torch Injector Support Adapter<br />
For ELAN 9000/DRC-e. For use with the Corrosion-Resistant<br />
Torch and the Ryton Scott Spray Chamber. For cassette torch<br />
mounts (manufactured after April 2005).<br />
Part No. Each (€)<br />
Injector Support Adapter O-Ring Kit<br />
For ELAN 9000/6X00/5000/DRCs.<br />
Includes O-Rings for all Injector<br />
Support Adapters.<br />
Injector Support Adapter O-Rings<br />
WE023951 168<br />
For ELAN DRC II. Pass-through design for use with ball<br />
joint injectors. For use with cassette torch mounts<br />
(manufactured after April 2005).<br />
Part No. Each (€)<br />
W1012406 214<br />
For ELAN 9000/6X00/5000/DRC-e. For use with the<br />
Corrosion-Resistant Torch and the Ryton Scott Spray<br />
Chamber. For twist type torch mounts<br />
(manufactured before April 2005). Part No. Each (€)<br />
N8122007 62<br />
N8120116 79<br />
W1013266 214<br />
Part No.<br />
Each (€)<br />
N8120100 4<br />
Position Torch Type Part No. Each (€)<br />
External Twist/Cassette 09210011 1<br />
Internal Twist/Cassette 09210012 1<br />
External (Large) Cassette W1013545 4<br />
Sample Introduction Inductively Coupled Plasma – MS<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
195
Sample Introduction<br />
Nebulizers<br />
Concentric Nebulizers<br />
Concentric Teflon Nebulizer – PFA-ST<br />
Inductively Coupled Plasma – MS Sample Introduction<br />
Concentric Teflon Nebulizer – PFA-ST Part No. N8122192<br />
The PFA-ST Nebulizer features high purity, HF-resistance,<br />
and high performance, along with an exchangeable external<br />
sample uptake capillary. The sample uptake rate is controlled<br />
by the dimension of the external capillary or probe. For use<br />
with autosamplers. Requires a CTFE Union (N8122355) to<br />
connect to the UltraClean Autosampler Probe.<br />
All-Teflon construction, chemically inert<br />
Chemically resistant – ideal for strong acids, alkalis, organics<br />
Resistant to clogging – reliably self-aspirated or pumped<br />
Low, spike-free background for important elements<br />
such as Fe and Ca<br />
Produces a fine aerosol for high transport efficiency<br />
and high sensitivity<br />
Analyze all sample types with a single introduction system<br />
Direct analysis of volatile and non-volatile organic solvents<br />
External threaded interface designed for zero dead<br />
volume connections and easy maintenance<br />
Exchangeable uptake capillaries allow one nebulizer to be<br />
used at different self-aspiration rates from 100 to 400 μL/min.<br />
Can be pumped from<br />
Part No. Each (€)<br />
0.1 to 3 mL/min.<br />
N8122192 1849<br />
Teflon Sample Capillaries for PFA-ST Nebulizers<br />
PFA sample capillaries for use with PFA-ST nebulizer.<br />
Size Uptake Rate Part No. Each (€)<br />
0.5 mm i.d. 400 μL/min. N8122384 158<br />
0.25 mm i.d. 100 μL/min. N8122383 158<br />
Concentric Teflon Nebulizer – PFA-20<br />
UltraClean PFA Teflon nebulizer with<br />
20 μL/min. free aspiration uptake rate.<br />
Not for use with autosamplers.<br />
Part No.<br />
Each (€)<br />
N8122350 1913<br />
Concentric Teflon Nebulizer – PFA-100 Part No. N8122351<br />
Concentric Teflon Nebulizer – PFA-100<br />
UltraClean PFA Teflon Nebulizer with<br />
100 μL/min. free aspiration uptake rate.<br />
Not for use with autosamplers.<br />
MEINHARD Nebulizers<br />
Part No.<br />
The MEINHARD ® Concentric Nebulizer reflects exacting<br />
standards in design and manufacturing. Its advantages<br />
include simplicity of design and operation, reproducible<br />
and self-aligning aerosol, and close fabrication control.<br />
They provide excellent sensitivity and precision for aqueous<br />
solutions and samples with few dissolved solids (less than<br />
1%). MEINHARD Nebulizers are self-aspirating. Not to be<br />
used with solutions containing hydrofluoric acid. PerkinElmer<br />
offers three types for ICP-MS: MEINHARD C3, K, and A3.<br />
All MEINHARD Nebulizers require an End Cap (N0680504)<br />
for use with Ryton Scott Spray Chambers. The Type A3 is<br />
an all quartz concentric nebulizer and ships standard on the<br />
ELAN DRC/DRC plus /DRC II.<br />
MEINHARD Model Material Part No. Each (€)<br />
Type C3 Glass N8102011 867<br />
Type K Glass N0681574 918<br />
Type A3 Quartz WE024371 533<br />
Liquid Connector for Concentric Nebulizers<br />
Low dead volume PEEK connector for use with MEINHARD<br />
Concentric Nebulizers. Requires 0.062 in. (1.59 mm) o.d.<br />
tubing (WE024375). Standard on ELAN DRCs. Not required<br />
for PFA Teflon Nebulizers.<br />
Part No. Each (€)<br />
WE024372 110<br />
Teflon Sample Capillary for Concentric Nebulizers<br />
Each (€)<br />
N8122351 1849<br />
PFA sample capillary 0.062 o.d. x 0.020 i.d. in (1.59 x 0.5 mm)<br />
60 cm length. For use with the Liquid Connector for<br />
Concentric Nebulizers (WE024372). Standard on the<br />
ELAN DRC/DRC plus /DRC II.<br />
Part No. Each (€)<br />
WE024375 1<br />
196
Sample Introduction<br />
Nebulizers<br />
MicroMist Nebulizers<br />
The MicroMist micro-uptake glass concentric nebulizer offers<br />
high performance for limited sample volumes. MicroMists<br />
with sample uptakes 0.2 - 0.4 mL/min. are fitted with an<br />
EzyFit connector with 1.3 o.d. x 0.50 mm i.d. x 700 mm<br />
long sample tubing. MicroMists with sample uptakes<br />
0.05 - 0.1 mL/min. are fitted with an EzyFit connector<br />
with 1.3 o.d. x 0.25 mm i.d. x 700 mm long sample tubing.<br />
All MicroMist Nebulizers offered by PerkinElmer are<br />
supplied with the EzyLok Argon connector.<br />
MicroMist Nebulizer Part No. N0775342<br />
MicroMist Nebulizers with 1 L/min. Ar Flow<br />
Uptake Rate Part No. Each (€)<br />
0.4 mL/min. N0775341 590<br />
0.2 mL/min. N0775342 677<br />
0.1 mL/min. N0775343 677<br />
0.05 mL/min. N0775344 870<br />
SeaSpray Nebulizer<br />
The SeaSpray Concentric Nebulizer is ideal for samples with<br />
high dissolved solids and offers outstanding nebulization<br />
efficiency for trace level analysis. It offers freedom from<br />
clogging while nebulizing solutions near the limit of<br />
solubility of most mineral salts, and conferring significant<br />
sensitivity gains. The SeaSpray Nebulizer for use with the<br />
ELAN series allows an Ar Flow Rate up to 1 L/min. and an<br />
Uptake Rate up to 2 mL/min.<br />
The SeaSpray is supplied with an EZT-075 EzyFit connector<br />
(sample tube 0.75 i.d. x 1.3 mm o.d.). All SeaSpray Nebulizers<br />
offered by PerkinElmer are supplied<br />
with the EzyLok Argon connector. Part No. Each (€)<br />
SeaSpray Nebulizer Part No. N0775340<br />
PFA End-Cap<br />
Used to fit any Concentric Nebulizer<br />
onto the end of the 47 mm PFA<br />
Scott Spray Chamber.<br />
N0775340 750<br />
Part No.<br />
Each (€)<br />
N8122357 638<br />
Ryton End-Cap for Concentric Nebulizers<br />
Ryton End-Cap to fit any<br />
Concentric Nebulizer onto a<br />
Ryton ScottSpray Chamber.<br />
O-Rings for Concentric Nebulizer End Cap<br />
Size Part No. Each (€)<br />
Small 00473194 4<br />
Large 09902153 1<br />
GemClean<br />
Cross-Flow II Nebulizer<br />
GemClean Cross-Flow II Nebulizer<br />
Cross-Flow II Replacement GemTips<br />
Includes a Clear Sapphire<br />
Sample Tip and a Red Ruby<br />
Argon Tip optimized for ICP-<br />
MS. The tips are constructed of<br />
PEEK for maximum corrosion<br />
resistance. Used in all<br />
GemClean Cross-Flow II<br />
Nebulizers produced after<br />
September 1998. Not for use with Cross-Flow Nebulizers<br />
produced before September 1998.<br />
Part No. Each (€)<br />
Cross-Flow Replacement GemTips<br />
For use in all Cross-Flow Nebulizers produced before<br />
September 1998. Includes a Clear Sapphire Sample Tip and<br />
a Red Ruby Argon Tip. The tips are constructed of PEEK for<br />
maximum corrosion resistance. Not<br />
for use with Cross-Flow II Nebulizers. Part No. Each (€)<br />
N0580624 112<br />
Cross-Flow Nebulizer O-Ring Kit<br />
Complete set of O-Rings for use with<br />
Cross-Flow and Cross-Flow II Nebulizers.<br />
Cross-Flow II Nebulizer Argon Ferrule<br />
For use with Cross-Flow II<br />
Nebulizers only.<br />
Part No.<br />
Each (€)<br />
N0680504 261<br />
For ELAN DRC-e/9000/6X00/5000/500/250. Complete<br />
chemically inert Cross-Flow II Nebulizer Assembly for<br />
ICP-MS. Specially processed to reduce BEC levels below<br />
1 ppb. Contains a Ryton End-Cap with a GemTip Clear<br />
Sapphire Sample Tip and a GemTip Red Ruby Argon Tip<br />
optimized for ICP-MS.<br />
Part No. Each (€)<br />
N8120516 510<br />
N8120515 113<br />
Part No.<br />
Each (€)<br />
N9300067 33<br />
Part No.<br />
Each (€)<br />
09920515 9<br />
Sample Introduction Inductively Coupled Plasma – MS<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
197
Sample Introduction<br />
Nebulizers<br />
Inductively Coupled Plasma – MS Sample Introduction<br />
Cross-Flow II Nebulizer Sample Ferrule<br />
For use with Cross-Flow II<br />
Nebulizers only.<br />
Cross-Flow II Nebulizer Ferrule Kit<br />
Contains five Sample and<br />
five Argon Ferrules.<br />
End Cap for Cross-Flow II Nebulizer<br />
Contains only the Cross-Flow II End-Cap<br />
with no Fittings or Nebulizer Tips.<br />
GemClean Cross-Flow II<br />
Nebulizer Replacement Parts<br />
Part No.<br />
Each (€)<br />
N0680612 55<br />
Part No.<br />
Each (€)<br />
N8122239 201<br />
GemClean Cross-Flow II Ryton Nebulizer Assembly<br />
Shipped after September 1998.<br />
Components Part No. Each (€)<br />
1 1 Sample Ferrule - TBG 1/16 Tefzel 09920518 9<br />
2 Nut - TBG PEEK 09920516 19<br />
3 Nut 09920517 19<br />
4 Argon Ferrule - TBG 1/8 Tefzel 09920515 9<br />
5 O-Ring, 18W, 1 3/8 i.d., 1 5/8 o.d. 09902033 5<br />
6 Ring 00473543 28<br />
7 O-Rings (2) 09921045 1<br />
8<br />
0.126 i.d., 0.040 w.d., Viton<br />
End Cap Cross-Flow II Nebulizer N8122239 201<br />
9 GemTip Kit for Cross-Flow II Nebulizer N8120515 113<br />
(Contains one each: Argon and Sample tip)<br />
9a<br />
9b<br />
Red Ruby Nebulizer, Argon Tip<br />
Clear Nebulizer Sample Tip<br />
10 Screws (2) - Knurled 00473539 15<br />
10<br />
6<br />
5<br />
7<br />
1<br />
2<br />
8<br />
9b<br />
7<br />
Part No.<br />
10<br />
9a<br />
4<br />
Each (€)<br />
09920518 9<br />
3<br />
Microconcentric Nebulizers<br />
CETAC MCN-100 Microconcentric Nebulizer<br />
Operates at low-flow rates with efficiency that approaches<br />
50%. With flow rates of only 30 μL/min., it can provide<br />
detection limits of a pneumatic nebulizer operating at up<br />
to 1000 μL/min. Total analysis can be<br />
performed on small sample volumes.<br />
HF resistant, high solids capability.<br />
Part No.<br />
N0691702<br />
Each (€)<br />
975<br />
CETAC Aridus Desolvating Microconcentric Nebulizer<br />
For use in ICP-MS when polyatomic spectral interferences<br />
degrade detection limits for certain elements. By the use of<br />
a membrane desolvation system, matrix and solvent species<br />
are swept out of the sample line, never reaching the plasma.<br />
As a result, many polyatomics, like ArO and ArH, are<br />
dramatically reduced, enabling elements like Fe, Ca, and K<br />
to be determined under normal plasma conditions.<br />
Voltage Part No. Each (€)<br />
110 V N8122340 20300<br />
220 V N8122341 20300<br />
198
Sample Introduction<br />
Nebulizers and Peristaltic Pump Supplies and Accessories<br />
Ultrasonic Nebulizers<br />
CETAC Ultrasonic Nebulizer<br />
The Ultrasonic Nebulizer expands the analytical capacity<br />
of your ICP-MS instrument by increasing your sample<br />
introduction efficiency. With this increased efficiency, you<br />
can typically expect an improvement of detection limits<br />
by a factor of 10.<br />
The Ultrasonic Nebulizer uses mechanical forces from an<br />
oscillating transducer to break a liquid sample stream into<br />
very small droplets with a relatively uniform droplet size.<br />
Because the formation of this fine aerosol is so efficient, a<br />
desolvation system consisting of a heated tube and a<br />
condenser is placed after the nebulization chamber to<br />
remove most of the water.<br />
U-6000AT + Ultrasonic Nebulizer System<br />
The U-6000AT + adds a third desolvation stage (membrane<br />
desolvation) which effectively removes water vapor from<br />
the aerosol stream. This eliminates the principal source<br />
of oxygen and hydrogen from the ICP improving detection<br />
limits for elements such as Ca, Fe, and K by a factor of<br />
10 to 100 for ICP-MS.<br />
Organic Analysis by ICP-MS<br />
With the U-6000AT + , trace elements can be determined in<br />
most organic solvents. The aerosol introduced into the ICP-<br />
MS, is virtually free of volatile organic solvent. Trouble-free<br />
determinations of analytes dissolved in solvents such as<br />
kerosene, methanol, THF, n-MP, and IPA are accomplished.<br />
The U-6000AT + can be used with all PerkinElmer ICP and<br />
ICP-MS instruments. Includes one Ultrasonic Nebulizer and<br />
Cooling System.<br />
Voltage Part No. Each (€)<br />
115 V, 50/60 Hz N0691709 26400<br />
230 V, 50/60 Hz N0691710 26400<br />
U-5000AT + Ultrasonic Nebulizer System<br />
The U-5000AT + Ultrasonic Nebulizer offers enhanced<br />
detection limits (up to 10x and greater) for ICP-MS.<br />
Can be used with all PerkinElmer ICP-MS instruments.<br />
Includes one Ultrasonic Nebulizer with two stages of<br />
Peltier cooled desolvation.<br />
Voltage Part No. Each (€)<br />
115 V, 50/60 Hz N8120140 13800<br />
230 V, 50/60 Hz N8120141 13800<br />
Ultrasonic Nebulizer Accessories<br />
Description Part No. Each (€)<br />
Drain Pump Tubing and Connector Kit N8122150 183<br />
Transducer Assembly N8122161 933<br />
KALREZ ® O-Ring for Spray Chamber N8122162 561<br />
Gilson Peristaltic Pump<br />
and Accessories<br />
Gilson ® Minipulse 3, Four-Channel Peristaltic Pump<br />
For ELAN 6X00/5000. 230 V, 50/60 Hz.<br />
Interface Cable for Computer-Control of Gilson<br />
Minipulse 3 Peristaltic Pump<br />
For ELAN 6X00 series.<br />
Replacement Head for Gilson Minipulse 3,<br />
Four-Channel Peristaltic Pump<br />
A replacement head (only) for<br />
Gilson Four-Channel Peristaltic Pump.<br />
Peristaltic Pump Tubing<br />
Peristaltic Pump Tubing<br />
Part No.<br />
Peristaltic pump tubing comes in a package of 12,<br />
30 cm (1 foot) lengths, unless otherwise noted.<br />
Each (€)<br />
N8122126 3877<br />
Part No.<br />
Each (€)<br />
N8125003 759<br />
Part No.<br />
Each (€)<br />
N8122127 1709<br />
Dimensions Color Specifications Part No. Each (€)<br />
0.76 mm i.d. Black/ Standard PVC Peristaltic 09908587 59<br />
Black Pump Tubing, resistant to<br />
most mineral acids. Two stop.<br />
1.14 mm i.d.* Red PVC Tubing for 2 mL/min. N0680375 99<br />
flow rate. Two stop.<br />
3.16 mm i.d. Black/ Drain Tubing for Peristaltic N8122012 37<br />
White Pump. Two stop.<br />
2.79 mm i.d. Violet/ Solvent Flex Tubing, 02508080 37<br />
White Two stop. 1<br />
0.76 mm i.d. Black/ Solvent Flex Tubing, 00473550 59<br />
Black Two stop. 1<br />
1.14 mm i.d. Red Solvent Flex Tubing, N0680376 92<br />
Two stop.<br />
0.76 mm i.d. Black/ Silicone Manifold Tubing, 00473552 88<br />
Black for use with organic solvents,<br />
including MIBK. Two stop. 2<br />
2.79 mm i.d. Violet/ Silicone Manifold Tubing, 09923448 37<br />
White for use with organic solvents,<br />
including MIBK. Two stop. 2<br />
2.79 mm i.d. Violet/ Pharmed Drain Tubing for N8122252 126<br />
White Peristaltic Pump, for use<br />
with organic solvents. Two stop.<br />
* Includes 6 in. (152 mm) PTFE Tubing (09985708) to adapt 0.045 in.<br />
(1.14 mm) i.d. tubing to the Nebulizer Capillary Tubing (09908265).<br />
1<br />
Specially formulated PVC for use with Kerosene or Xylene.<br />
Not recommended for use with MIBK (Methyl Isobutyl Ketone).<br />
2<br />
Not recommended for use with Kerosene or Xylene.<br />
Sample Introduction Inductively Coupled Plasma – MS<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
199
Sample Introduction<br />
Sample Introduction Systems and Replacement Parts<br />
Inductively Coupled Plasma – MS Sample Introduction<br />
Organic Sampling Systems<br />
Peltier Cooled Organic Sample Introduction System<br />
Complete sample introduction system used for the<br />
determination of contaminant’s in light organic solvents<br />
and with HPLC speciation using organic mobile phases ><br />
5% MeOH. User selectable temperature settings of 2° and<br />
-5 °C. Consists of: Peltier-cooled Quartz Cyclonic Spray<br />
Chamber with Oxygen Port, PFA-ST Concentric Nebulizer,<br />
2.0 mm Quartz Injector, Pharmed Peristaltic Pump Tubing,<br />
Teflon Drain Tubing, Oxygen, and Make-up Gas Lines.<br />
110/220 V, 50/60 Hz.<br />
PC 3 Spray Chamber<br />
The PC 3 is the first Peltier-cooled quartz cyclonic spray<br />
chamber for ICP-MS and ICP-OES. The quartz cyclonic<br />
spray chamber offers the advantages of low-memory effects,<br />
fast rinse-out, and in many cases higher sample transport<br />
efficiency. The PC 3 cools the outer walls of the cyclonic<br />
spray chamber to a constant temperature. This reduces<br />
polyatomic ion interferences, such as oxides, for ICP-MS<br />
analysis. The PC 3 reduces solvent loading when volatile<br />
organic solvents are analyzed. Thermal stabilization of the<br />
spray chamber also enhances long-term stability for both<br />
ICP-MS and ICP-OES, particularly for laboratories where<br />
room temperature is not constant.<br />
A PFA Nebulizer is used to introduce samples to the PC 3 .<br />
The nebulizer attaches to the O-Ring Free Cyclonic Spray<br />
Chamber using a one-piece Teflon PFA ferrule-nut.<br />
Torch Type Part No. Each (€)<br />
Cassette Torch Mount N8122410 3714<br />
Twist Type Torch Mount N8122389 3714<br />
PC 3 Spray Chamber, included in the Peltier Cooled Organic<br />
Sample Introduction System Part No. N8122389<br />
Heavy Organic Sample Introduction System<br />
For the ELAN 9000/6X00/5000/DRCs, requires but does not<br />
include, a Heavy Organics Chiller. This accessory is a complete<br />
sample introduction system used for the determination of<br />
contaminant’s in organic solvents that range in volatility from<br />
acetone to kerosene. Recommended for use with heavy<br />
organics that have low oxygen content. Consists of: Glass<br />
Water-cooled Scott Spray Chamber, Glass Concentric<br />
Nebulizer, Ryton End-Cap, 0.85 mm i.d. Alumina Injector,<br />
Viton Peristaltic Pump Tubing, Organic Waste Container,<br />
all necessary connecting hardware, and tubing.<br />
Many organic solutions with low oxygen content will<br />
require the addition of a small amount of oxygen, into the<br />
plasma. Platinum Sampler and Skimmer Cones should<br />
always be used whenever oxygen is added to the plasma.<br />
When used with the ELAN 9000/6X00 series, the Mass Flow<br />
Controller Assembly for Organic Sampling Systems (N8120161)<br />
is required, but not included.<br />
The ELAN DRC/DRC plus requires the Mass Flow Controller<br />
Assembly for Organic Sampling Systems (N8120161), the<br />
Injector Support Adapter for ELAN 9000/6X00/5000/DRC-e<br />
(Twist Type-N8122007 or Cassette Type-W1013266), and<br />
Retaining Ring for ELAN DRC-e/9000/ 6X00/5000 (WE014081).<br />
The ELAN DRC II requires the Oxygen Gas Mass Flow<br />
Controller Upgrade Kit (WE028428), the Injector Support<br />
Adapter for ELAN 9000/6X00/5000/DRC-e (Twist Type-<br />
N8122007 or Cassette Type-W1013266),<br />
and Retaining Ring for ELAN<br />
Part No. Each (€)<br />
DRC-e/9000/6X00/5000 (WE014081).<br />
N8122132 7100<br />
Organic Sampling System Consumables Kit<br />
For the ELAN 9000/6X00/5000/DRCs. Included with the<br />
Heavy Organic Sample Introduction System (N8122132).<br />
Contains tubing for oxygen inlet,<br />
peristaltic pump tubing, and O-rings. Part No. Each (€)<br />
Sample Introduction Systems<br />
PFA Teflon Sample Introduction Systems<br />
Designed for use with either a Cassette or a Twist Type<br />
Torch Mount. Consists of a 47 mm PFA Scott Spray<br />
Chamber (N8122356), PFA End-Cap (N8122357) with<br />
two PFA-100 Concentric Nebulizers (N8122351), either a<br />
Sapphire or a Platinum Injector in PFA support (see table<br />
below), and a Demountable Quartz Torch (N8122006).<br />
Torch Type Injector Type Part No. Each (€)<br />
Cassette Torch Mount Sapphire 1.8 mm i.d. N8122414 6000<br />
Cassette Torch Mount Platinum 2.0 mm i.d. N8122415 7100<br />
Twist Type Torch Mount Sapphire 1.8 mm i.d. N8122362 6000<br />
Twist Type Torch Mount Platinum 2.0 mm i.d. N8122363 7100<br />
HF-Resistant Sample Introduction<br />
System for Cassette Torch<br />
N8122118 1116<br />
For use with ELAN DRC IIs (manufactured after April<br />
2005). Consists of a Ryton Scott Spray Chamber (N8120124)<br />
with a GemClean Cross-Flow II Nebulizer (N8120516), a 2<br />
mm i.d. Alumina Injector (N8126041), Injector Support<br />
Adapter with O-Rings (N8120116),<br />
Retaining Ring (WE014081), and Part No. Each (€)<br />
Drain Connector (WE013119).<br />
WE024782 2117<br />
200
Sample Introduction<br />
Sample Introduction Systems and Replacement Parts<br />
Replacement Parts for Twist Type Torch Models<br />
Twist Type Torch Replacement Parts<br />
for the ELAN 9000/6X00/5000<br />
For ELAN 9000/6X00/5000s manufactured before April 2005.<br />
3<br />
Components Part No. Each (€)<br />
6<br />
1 Ryton Scott Spray Chamber N8120124 402<br />
12<br />
Large O-Ring WE013060 1<br />
for Ryton Scott Spray Chamber<br />
13<br />
Retaining Ring WE014081 59<br />
14<br />
Right-Angled Drain Connector WE013119 230<br />
15<br />
External O-Ring 09210012 1<br />
for Injector Support Adapter<br />
16<br />
Internal O-Ring 09210011 1<br />
for Injector Support Adapter<br />
17<br />
Injector Support Adapter N8122007 62<br />
for ELAN 9000/6X00/5000<br />
18<br />
GemClean Cross-Flow II Nebulizer N8120516 510<br />
Twist Type Torch Replacement Parts for the ELAN DRC<br />
For ELAN DRCs manufactured before April 2005.<br />
Components Part No. Each (€)<br />
E3 9 Safety Shield/Clamp Assembly W1020996 214<br />
10 E2 Baffled Quartz Cyclonic Spray Chamber WE025221 898<br />
11 E3 MEINHARD Type A3 WE024371 533<br />
All-Quartz Concentric Nebulizer<br />
12 E1 Liquid Connector WE024372 110<br />
for Concentric Nebulizers<br />
13 E1 Retaining Ring WE025239 57<br />
for Baffled Quartz<br />
Cyclonic Spray Chamber<br />
14 E1 Ball Joint Injector Support Adapter WE023951 168<br />
for ELAN DRCs<br />
5<br />
ELAN 9000/6X00/5000<br />
5<br />
13<br />
ELAN DRC<br />
14<br />
6<br />
7<br />
10<br />
8<br />
9<br />
2<br />
11<br />
1<br />
12<br />
4<br />
Sample Introduction Inductively Coupled Plasma – MS<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
201
Sample Introduction<br />
Spray Chambers<br />
Baffled Cyclonic Spray Chambers<br />
Water-Cooled Baffled Glass Cyclonic Spray Chamber<br />
for ELAN DRC/DRC plus /DRC II<br />
The Water-Cooled design permits the introduction of<br />
coolant for temperature control. Thermostatting to constant<br />
temperature helps ensure highly reproducible results and<br />
long term stability. Can also be cooled to suppress<br />
volatilization, allowing the direct aspiration of highly<br />
volatile solvents such as naphtha and petrol/gasoline.<br />
Inductively Coupled Plasma – MS Sample Introduction<br />
The spray chamber is an integral part of the sample<br />
introduction system responsible for filtering the sample<br />
mist to permit the appropriate droplet size distribution to<br />
reach the plasma.<br />
The Baffled Cyclonic Spray Chamber features a central<br />
transfer tube which acts as a secondary particle separator<br />
helping separate larger aerosol particles from the sample. This<br />
reduces solvent load in the plasma without compromising<br />
detection limits.<br />
The distance between the bottom of the baffle and the<br />
chamber wall is carefully controlled so that droplets cannot<br />
form on the bottom of the baffle. The advantage is smooth<br />
draining and improved precision.<br />
Baffled Quartz Cyclonic Spray Chamber<br />
For ELAN DRC/DRC plus /DRC II.<br />
Baffled Quartz Spray Chamber<br />
(Teflon O-ring type) with ball joint.<br />
Safety Shield/Clamp Assembly<br />
for the Baffled Quartz Spray Chamber<br />
Polypropylene safety shield/clamp assembly for the Baffled<br />
Quartz Cyclonic Spray Chamber<br />
(WE025221) used on ELAN<br />
DRC/DRC plus /DRC II.<br />
Part No.<br />
W1020996<br />
Each (€)<br />
214<br />
O-Ring for Baffled Quartz Cyclonic Spray Chamber<br />
Teflon coated Viton. Standard on<br />
Baffled Quartz Cyclonic Spray<br />
Chamber (WE025221).<br />
Retaining Ring for the Baffled<br />
Quartz Cyclonic Spray Chamber<br />
Baffled Quartz Cyclonic<br />
Spray Camber<br />
Part No. WE025221<br />
Part No.<br />
Each (€)<br />
WE025221 898<br />
Part No.<br />
Each (€)<br />
09210011 1<br />
Retaining ring for use with the Baffled Quartz Cyclonic Spray<br />
Chamber (WE025221) used on the ELAN DRC/DRC plus /DRC II.<br />
Not for Ryton Scott Spray Chambers.<br />
Torch Type Part No. Each (€)<br />
Cassette Torch Mount W1020331 71<br />
Twist Type Torch Mount WE025239 57<br />
The Water-Cooled Cyclonic Spray Chamber with oxygen<br />
port and ball joint connection is designed for use with the<br />
ELAN DRC/ DRC plus /DRC II. Glass with<br />
baffle. Recommended for light organic<br />
solvents and chromatography use.<br />
Part No.<br />
N8120181<br />
Each (€)<br />
1339<br />
Water-Cooled Baffled Glass Cyclonic Spray Chamber<br />
Water-Cooled Cyclonic Spray Chamber with oxygen port and<br />
ball joint connection for use with the ELAN DRC-e/9000/<br />
6X00/5000. Glass with baffle. Recommended for light organic<br />
solvents and chromatography use. Requires, but does not<br />
include, Cyclonic Spray Chamber<br />
Mount (WE014034) for first time use. Part No. Each (€)<br />
Water-Cooled O-Ring Free<br />
Baffled Glass Cyclonic Spray Chamber<br />
Water-Cooled O-Ring Free Cyclonic<br />
Spray Chamber for use with the<br />
ELAN DRC-e/9000/6X00/5000.<br />
The O-Ring Free design eliminates<br />
the O-Ring seal between the<br />
nebulizer and the spray chamber.<br />
It has several important features:<br />
Simple nebulizer insertion and removal<br />
No O-Rings to replace<br />
Smooth lock and release mechanism<br />
Faster washout times due to elimination of dead<br />
volume around the nebulizer seal<br />
Positive stop to ensure your nebulizer<br />
is correctly positioned every time<br />
Part No.<br />
N0775353<br />
Each (€)<br />
1340<br />
Cyclonic Spray Chamber Mount<br />
N8120180 1339<br />
Mounting hardware for use with the Water-cooled Baffled<br />
Cyclonic Spray Chamber (N8120180), the Cyclonic Spray<br />
Chamber (N8122188), or the Water-Cooled O-Ring Free<br />
Baffled Cyclonic Spray Chamber (N0775353) on the<br />
ELAN DRCe/9000/6X00/5000.<br />
Part No. Each (€)<br />
WE014034 191<br />
202
Sample Introduction<br />
Spray Chambers<br />
Cyclonic Spray Chamber<br />
The cyclonic spray chamber<br />
relies on momentum to<br />
efficiently and quickly<br />
remove the larger droplets<br />
from the sample mist<br />
decreasing any opportunity<br />
for occlusion or agglomeration<br />
of the smaller droplets. The<br />
result is higher efficiency,<br />
better precision, and faster<br />
washouts than other spray<br />
chamber designs.<br />
Save time and expense<br />
O-Ring Free Cyclonic Spray Chamber<br />
Part No. N0775350<br />
1. Decreased sample introduction system installation and<br />
optimization time due to the preset nature of the spray<br />
chamber/nebulizer combination<br />
2. More samples per hour due to minimal dead volume<br />
and efficient draining<br />
Unique design characteristics<br />
1. The nebulizer port is oversized so that sample solution<br />
cannot build up around the nebulizer as it will in other<br />
cyclonic designs. This translates to less carryover,<br />
faster washout times, and greater productivity from<br />
your Optima<br />
2. The nebulizer port angle is tightly controlled so that the<br />
nebulizer mist impacts on the same chamber wall area<br />
in each and every spray chamber. The angle of incidence<br />
is critical in determining the efficiency of large<br />
droplet removal<br />
3. A trace metal free plastic nebulizer Adapter is employed<br />
to fix the depth of nebulizer insertion at the optimal<br />
position. Because of this, there is no need for an operator<br />
to move the nebulizer in and out of the port in an effort<br />
to locate the “sweet spot”<br />
4. Each spray chamber incorporates a precisely machined<br />
ridge along the inside top of the spray chamber. Both the<br />
angle and depth of the ridge are critical to performance.<br />
The result is efficient draining of sample waste and the<br />
elimination of large droplets being swept into the plasma.<br />
This eliminates the periodic “spiking” that adversely<br />
affects precision and fosters faster washout times<br />
Glass Cyclonic Spray Chamber Kit<br />
For use with the ELAN DRCe/9000/6X00/5000. Kit contains<br />
one Glass Cyclonic Spray Chamber, mounting hardware and<br />
instructions. Requires, but does not<br />
include, a Concentric Nebulizer. Not<br />
for use with ELAN DRC/DRC plus /DRC II.<br />
Part No.<br />
N8120150<br />
Each (€)<br />
976<br />
Glass Cyclonic Spray Chamber<br />
For use with the ELAN DRCe/9000/6X00/5000. Glass<br />
Cyclonic Spray Chamber only. Not for use with ELAN<br />
DRC/DRC plus /DRC II. Does not include the mounting hardware<br />
that is included in the Cyclonic Spray<br />
Chamber Kit (N8120150).<br />
Part No. Each (€)<br />
O-Ring Free Glass Cyclonic Spray Chamber<br />
For use with the ELAN DRCe/9000/ 6X00/5000. O-Ring<br />
Free Glass Cyclonic Spray Chamber only. Not for use with<br />
ELAN DRC/DRC plus /DRC II.<br />
Part No. Each (€)<br />
Water-Cooled O-Ring Free Glass<br />
Cyclonic Spray Chamber<br />
N8122188 606<br />
N0775350 584<br />
O-Ring Free Glass Cyclonic<br />
Spray Chamber only. Ball<br />
joint type. For use with the<br />
ELAN DRC/DRC plus /DRC II.<br />
Part No.<br />
Each (€)<br />
N0775354 1260<br />
Sample Introduction Inductively Coupled Plasma – MS<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
203
Sample Introduction<br />
Spray Chambers<br />
Drain Components<br />
Scott Spray Chamber<br />
Inductively Coupled Plasma – MS Sample Introduction<br />
Right-Angled Drain Connector<br />
Teflon connector used to connect Drain<br />
Tubing to Ryton Scott Spray Chamber.<br />
Drain Bottle<br />
For ELAN 9000/6X00/DRC series.<br />
Drain Bottle Cap Assembly<br />
For ELAN 9000/6X00/DRC series.<br />
Drain Adapter<br />
For ELAN 9000/6X00/DRC series.<br />
PFA Teflon Spray Chamber<br />
PFA Teflon Scott Spray Chamber<br />
UltraClean, low volume 47 mm Scott Spray Chamber.<br />
For use with concentric nebulizers.<br />
PFA Teflon construction<br />
Low contamination<br />
Chemically inert<br />
Ideal for dilute-and-shoot analysis<br />
O-ring-free seal reduces contamination<br />
Easy to clean, low maintenance<br />
High transmission and selectivity<br />
Requires a PFA Injector Assembly<br />
and the PFA End-Cap (N8122357).<br />
PFA End-Cap<br />
Used to fit a Concentric Nebulizer<br />
onto the end of the 47 mm PFA Scott<br />
Spray Chamber.<br />
Part No.<br />
Each (€)<br />
WE013119 230<br />
Part No.<br />
Each (€)<br />
09904991 112<br />
Part No.<br />
Each (€)<br />
N0690271 398<br />
Part No.<br />
Each (€)<br />
09920379 1<br />
Part No.<br />
Each (€)<br />
N8122356 1148<br />
Part No.<br />
Each (€)<br />
N8122357 638<br />
Water-Cooled Glass Scott Spray Chamber<br />
For ELAN DRC-e/9000/6X00/5000. Water-cooled Glass<br />
Scott Spray Chamber included in Heavy Organics Sample<br />
Introduction System (N8122132). Recommended for use<br />
with heavy organic solvents.<br />
Does not include End-Cap.<br />
Part No. Each (€)<br />
Ryton Scott Spray Chamber<br />
For ELAN 9000/6X00/5000. Complete HF-resistant Ryton<br />
Scott Spray Chamber. Includes (1) Large O-Ring (WE013060),<br />
(1) Retaining Ring (WE014081),<br />
and (1) Right-Angled Drain<br />
Connector (WE013119).<br />
Part No.<br />
N8120124<br />
Each (€)<br />
402<br />
Large O-Ring for the Ryton Scott Spray Chamber<br />
For use with the HF-resistant Ryton<br />
Scott Spray Chamber on the<br />
ELAN DRC-e/9000/6X00/5000.<br />
Retaining Ring for the Ryton Scott Spray Chamber<br />
For use with the HF-resistant Ryton<br />
Scott Spray Chamber on the<br />
ELAN DRC-e/9000/6X00/5000.<br />
PFA Teflon Scott Spray Chamber Part No. N8122356<br />
PFA End-Cap Part No. N8122357<br />
WE013829 4508<br />
Part No.<br />
Each (€)<br />
WE013060 1<br />
Part No.<br />
Each (€)<br />
WE014081 59<br />
204
Sample Introduction<br />
Torches and Torch Accessories<br />
RF Coils<br />
RF Coil Assembly for the ELAN 9000/6X00/DRCs<br />
Includes fittings, self-aligning.<br />
RF Coil Assembly for the ELAN 5000<br />
Self-aligning.<br />
Torch Alignment Tool<br />
For ELAN 9000/6X00/DRCs. Used<br />
to align the torch in the load coil.<br />
Power Amplifier Tube (Ceramic)<br />
For ELAN 9000/6X00/DRCs and<br />
ELAN 5000As manufactured<br />
after September 1992.<br />
Torches<br />
Demountable Quartz Torch<br />
For all ELANs.<br />
High Efficiency Demountable Quartz Torch<br />
For ELAN 9000/6X00/DRCs. Demountable quartz torch only.<br />
Operates at 25% reduced Argon gas flows compared to the<br />
Demountable Quartz Torch (N8122006). The ELAN 9000<br />
and 6X00 require the High Efficiency Torch Kit (W1007468)<br />
for first time installation.<br />
Part No. Each (€)<br />
High Efficiency Torch Kit<br />
Includes the High Efficiency Torch<br />
(W1008384) and flow restrictors required<br />
for use with the ELAN 9000 and 6X00.<br />
Cassette Torch Mount<br />
Part No.<br />
Part No.<br />
W1008384 377<br />
Part No.<br />
Each (€)<br />
WE021816 312<br />
Part No.<br />
Each (€)<br />
WE012411 249<br />
Part No.<br />
Each (€)<br />
WE015554 97<br />
Part No.<br />
Each (€)<br />
N0695477 2571<br />
Each (€)<br />
N8122006 287<br />
Each (€)<br />
W1007468 631<br />
The Cassette Torch Mount is a new, innovative torch design,<br />
introduced in April 2005, that is fully modular, demountable,<br />
rugged and easy to maintain. Now changing torch components<br />
is a simple process – no tools are required. Cassette Torch<br />
Mount does not include Demountable Quartz Torch or<br />
Injector (shown at the right).<br />
ELAN Model Part No. Each (€)<br />
DRC II W1020672 3698<br />
9000 W1020668 3698<br />
Teflon Ferrules<br />
For torch gas connectors.<br />
Description Part No. Each (€)<br />
Front Ferrule 09903119 4<br />
Back Ferrule 09903120 4<br />
Cassette Torch Replacement Parts<br />
Components Part No. Each (€)<br />
11<br />
Injector Nut W1012408 57<br />
12<br />
Injector Spacer W1012409 14<br />
13<br />
Internal O-Ring 09210011 1<br />
for Injector Support Adapter<br />
14<br />
Torch Spacer W1012410 26<br />
15<br />
Large External O-Ring W1013545 4<br />
for Injector Support Adapter<br />
16<br />
External O-Ring 09210012 1<br />
7<br />
for Injector Support Adapter<br />
Cassette Torch Injector Support W1013266 214<br />
Adapter for ELAN 9000/DRC-e<br />
18<br />
Ball Joint Cassette Torch Injector W1012406 214<br />
Support Adapter for ELAN DRC II<br />
19<br />
Cassette Torch Retaining Ring W1020331 71<br />
110<br />
Safety Shield/Clamp Assembly W1020996 214<br />
2<br />
1<br />
4<br />
3<br />
5 6<br />
Cassette Torch Mount Part No. W1020672<br />
9<br />
10<br />
7 For ELAN 9000/DRC-e<br />
8 For DRC II<br />
Sample Introduction Inductively Coupled Plasma – MS<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
205
ICP-MS Software<br />
ICP-MS Operating System and Application Software<br />
ELAN Software<br />
Inductively Coupled Plasma – MS ICP-MS Software<br />
ELAN 3.3 Software for ELAN 9000/6X00/DRCs<br />
Utilizing the powerful Windows ® XP operating system,<br />
the simple, intuitive software makes ICP-MS accessible to<br />
novices and experts alike. The software is designed<br />
specifically for ICP-MS and includes helpful guidelines that<br />
assist users in selecting the best mass for their particular<br />
matrices. Priority samples, flexible quality-control checks,<br />
transient signal handling, speciation analysis, runlist build,<br />
and customizable reporting are just a few of the features<br />
that will make your life easier (Figure 1). Integrated<br />
maintenance videos and our new PathFinder HTML-based<br />
Help system take the guesswork out of routine tasks. The<br />
SmartTune software wizard automatically sets up all your<br />
tuning procedures, runs them in the sequence you select,<br />
and reports the results based on user-selected pass/fail<br />
criteria. The software includes a library of standard reports<br />
and provides the flexibility to customize reports for your<br />
methods, without having to use a complicated macro<br />
language or exit to another program. The powerful ELAN<br />
software provides effortless operation, all day, every day.<br />
Figure 1: The Build Run List feature will automatically build an exact listing of<br />
all your standards, quality-control checks and samples before you start your<br />
automated analysis – eliminating unexpected sample-run orders and errors.<br />
Upgrade to ELAN 3.3 for use with Chromera Speciation<br />
software. Chromera Speciation software requires<br />
Windows XP SP2.<br />
ELAN 3.3 requires Windows 2000 Pro SP3 or<br />
Windows XP Pro SP2. Service installation not included.<br />
Part No.<br />
Each (€)<br />
W1015115 630<br />
ELAN 3.2 Enhanced Security Software<br />
for ELAN 9000/6X00/DRCs<br />
ELAN Enhanced Security (ES) is an optional software<br />
package that gives you the security, data integrity, and<br />
traceability tools needed to develop FDA-compliant standard<br />
operating procedures, whether you are in a research or<br />
manufacturing environment. User authenticity is verified<br />
by ELAN ES software to ensure that access is limited to<br />
authorized individuals and permissions to perform specific<br />
tasks are controlled. All raw data, including methods and<br />
parameters used, are stored in an encrypted, checksumprotected<br />
dataset, in order to guard against data tampering.<br />
Audit trails that capture file, system, and security-related<br />
events provide traceability to most software actions.<br />
ELAN ES software offers the following features:<br />
Data archival tools simplify long-term data storage<br />
User authenticity is verified by ELAN ES to ensure<br />
access is limited to authorized individuals<br />
File changes are “stamped” with user ID, user name,<br />
date/time, and description<br />
Checksum ensures data tampering is detected<br />
ELAN ES software provides ultimate security for<br />
the regulated environment:<br />
Controlled access to ELAN ES application<br />
Customizable security-feature configuration<br />
Controlled permissions to perform certain operations<br />
ELAN 3.2 ES requires<br />
Windows XP Professional SP2.<br />
Instrument Remote Control Kit<br />
for ELAN 9000/6X00/DRCs<br />
Part No.<br />
Each (€)<br />
W1013691 6600<br />
Contains software and analog modem to control ELAN<br />
9000/6X00/DRC series instruments from a remote location.<br />
For use with analog telephone lines only – not for ISDN.<br />
Requires a second computer (not included). Service<br />
installation required.<br />
Part No. Each (€)<br />
09410047 580<br />
206
Speciation by Chromatography<br />
Speciation Supplies<br />
Chromera Speciation Software<br />
Chromera Speciation Module for ICP-MS<br />
Quantitation, integration, peak identification, and reporting<br />
software for elemental speciation on the ELAN 9000/6X00/<br />
DRC series of instruments to HPLC systems. Chromera<br />
provides fully integrated control of PerkinElmer Series 200<br />
HPLC systems. Includes computerized switching valve and<br />
read cable. Requires Windows XP Pro<br />
SP2 and ELAN 3.3 software. Service Part No. Each (€)<br />
installation not included.<br />
N8120191 4206<br />
TotalChrom ICP-MS to Chromera Upgrade<br />
Requires existing TotalChrom license. Includes Chromera<br />
speciation module and ELAN 3.3 software. Service<br />
installation not included.<br />
Part No. Each (€)<br />
HPLC Columns for Speciation<br />
Bromine Speciation in Drinking Water<br />
INTENSITY (CPS)<br />
1200<br />
1000<br />
800<br />
600<br />
400<br />
200<br />
0<br />
CHROMATOGRAPHIC CONDITIONS<br />
Sample Type: Drinking Water<br />
Column: 5 μm x 15 cm Anion Exchange PRP-X100<br />
Species: Br - , Br0 3<br />
-<br />
Run Time: 7 minutes<br />
Notes: PEEK Hardware.<br />
Part No.<br />
0 100 200 300 400<br />
TIME (SECONDS)<br />
N8122253<br />
N8120192 2055<br />
BrO 3<br />
-<br />
Arsenic and Chromium Speciation in Drinking Water<br />
PULSE INTENSITY<br />
8000<br />
7000<br />
6000<br />
5000<br />
4000<br />
3000<br />
2000<br />
1000<br />
0<br />
As +3 As+5 Cr +6<br />
0 100 200<br />
TIME (SECONDS)<br />
CHROMATOGRAPHIC CONDITIONS<br />
Sample Type: Drinking Water<br />
Column: 3 μm x 3 cm Reduced Activity C8 Cartridge<br />
Species: As +3 , As +5 , Cr +3 , Cr +6<br />
Run Time: < 3 minutes<br />
Notes: Package of 5. Requires Column Holder (07150013) for first time use.<br />
Part No. 02580191<br />
Cr +3<br />
Arsenic Speciation in Urine<br />
Br - As +3<br />
AsB<br />
DMA<br />
As +5<br />
0 1 2 3 4 5 6 7 8 9 10<br />
TIME (SECONDS)<br />
CHROMATOGRAPHIC CONDITIONS<br />
Sample Type: Urine<br />
Column: 5 μm x 15 cm Anion Exchange PRP-X100<br />
Species: As +3 , As +5 , AsB, MMA, DMA<br />
Run Time: 9 minutes<br />
Notes: PEEK Hardware<br />
Part No.<br />
N8122253<br />
MMA<br />
Speciation by Chromatography Inductively Coupled Plasma – MS<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
207
Speciation by Chromatography<br />
Speciation Supplies<br />
Inductively Coupled Plasma – MS Speciation by Chromatography<br />
Guard Column Kit for As Speciation<br />
PRP-X100 Anion Exchange Guard Column Kit for As<br />
speciation. PEEK. Contains one column holder and two<br />
cartridges. For use with HPLC 3 μm<br />
column for As speciation (N8122256).<br />
Part No. Each (€)<br />
N8122254 226<br />
HPLC 3 μm Column for As Speciation<br />
3 μm x 15 cm PRP-X100 Anion Exchange Column for<br />
As speciation. PEEK hardware.<br />
For use with the CDC protocol for<br />
As speciation.<br />
Part No.<br />
N8122256<br />
Each (€)<br />
843<br />
HPLC Column Holder.<br />
For use with 3 cm columns.<br />
Speciation Accessories and Supplies<br />
Peltier Cooled Autosampler Tray for Series 200<br />
Peltier Controller for Autosampler Tray<br />
For use with Peltier Cooled Autosampler Tray (N2930035).<br />
Included in the Supplemental<br />
Arsenic Speciation Kit (N8120534). Part No. Each (€)<br />
Six-Port Switching Valve<br />
Two position PEEK switching valve for injecting internal<br />
standards or connection to ICP-MS. Internal port diameter<br />
0.38 mm (0.015"). Manual or RS232 control. Included with<br />
Chromera. 110/240 V, 50/60 Hz<br />
Part No. Each (€)<br />
HPLC Cable for ELAN 9000/6X00/DRCs<br />
To interface a Series 200 HPLC to the<br />
ELAN. With external stop function –<br />
requires v3.0 software for external stop.<br />
Part No.<br />
N2930035 1454<br />
N2930036 1849<br />
N8122251 1348<br />
Part No.<br />
Each (€)<br />
07150013 190<br />
100-position 2 mL vial tray. Temperature control from<br />
4-60 °C ± 1 °C. Requires Peltier Controller (N2930036).<br />
Included in the Supplemental<br />
Arsenic Speciation Kit (N8120534). Part No. Each (€)<br />
Each (€)<br />
W1007493 150<br />
Tubing Adapter<br />
Polypropylene Sample Vials<br />
0.6 mL Vial (pkg. 500) for use with<br />
Series 200 HPLC Autosampler.<br />
Not for Cr speciation.<br />
PEEK Solvent Filter<br />
PEEK In-Line Filter<br />
For filtering LC mobile phase<br />
after pump, 10 μm size.<br />
Speciation Kits<br />
Connects Peristaltic<br />
Pump Tubing used in<br />
ICP-MS to PEEK Tubing<br />
used in LC, for use<br />
in speciation.<br />
For filtering LC mobile<br />
phase, 10 μm size.<br />
Standard Flow LC-ICP-MS Interface Kit<br />
For connecting HPLC systems operating at flow rate<br />
> 0.5 mL/min. to the ELAN 9000/DRC-e. Includes a Glass<br />
Concentric Nebulizer, Spray Chamber,<br />
PEEK tubing, and fittings.<br />
Part No. Each (€)<br />
Supplemental Arsenic Speciation Kit<br />
Part No.<br />
Each (€)<br />
N8122258 29<br />
Part No.<br />
Each (€)<br />
N9302130 172<br />
Part No.<br />
Each (€)<br />
N8122249 33<br />
Part No.<br />
Each (€)<br />
N8122250 33<br />
N8120532 1071<br />
For labs who wish to use the CDC protocol for As speciation.<br />
Includes Peltier Cooled Autosampler Tray (N2930035), Peltier<br />
Controller (N2930036), HPLC 3 μm Column for As Speciation<br />
(N8122256), Guard Column, Six-port Switching Valve<br />
(N8122251), PEEK fittings, Solvent<br />
Bottle Tray, and 20 μL PEEK Sample Part No. Each (€)<br />
Loop. Requires HPLC system.<br />
N8120534 3100<br />
208
Standards<br />
PerkinElmer Pure Standards for ICP-MS<br />
Depend on Genuine<br />
PerkinElmer Pure Standards<br />
Whatever Your Application,<br />
You Can Count on PerkinElmer<br />
Pure Standards to Yield Reliable,<br />
Accurate Results<br />
PerkinElmer offers a wide selection of standards for ICP-MS.<br />
Each solution is supplied with a comprehensive Certificate<br />
of Analysis that documents the quality. To ensure that your<br />
measurements are accurate, you can rely on our certificates<br />
to provide complete information.<br />
PerkinElmer Pure Atomic Spectroscopy Standards are manufactured<br />
for PerkinElmer to the highest quality standards.<br />
Quality<br />
PerkinElmer Pure standards are prepared<br />
gravimetrically from high-purity metals<br />
and salts, using high-purity reagents.<br />
■ ASTM Type I, filtered water minimizes cations,<br />
anions, and colloids; resistivity is maintained in<br />
the 18-megohm range.<br />
■ Acids used are the highest purity.<br />
■ Semi-micro analytical balances and Class A volumetric<br />
glassware are used, and the bottles are subjected to a<br />
stringent leaching/cleaning process.<br />
■ Following preparation, standards are analyzed<br />
for the major element as well as trace impurities.<br />
The results of the analysis are provided on the<br />
Certificate of Analysis.<br />
Reliability<br />
Multi-element standards are measured<br />
by three methods:<br />
1. Complete analysis (wet and ICP)<br />
of the starting materials<br />
2. Wet and ICP analysis of the<br />
individual prepared standards<br />
3. ICP-MS check of the final multi-element standard<br />
The results of these three analyses are<br />
reported on the Certificate of Analysis.<br />
NIST or NBS SRMs used for the ICP<br />
check are also reported on the<br />
Certificate of Analysis.<br />
Safety<br />
We ship standards to comply with both<br />
DOT and IATA regulations to ensure<br />
their safe delivery to you.<br />
Features<br />
■ ISO 9001 accredited by Underwriters Laboratories<br />
including comprehensive continuous improvement,<br />
product recall, corrective action request, and other<br />
quality maintenance and improvement programs<br />
■ Accreditation by NVLAP/NIST as an EPA performance<br />
testing provider<br />
■ Product labeling meets OSHA and California<br />
labeling standards<br />
■ Bottles are low-density polyethylene from industry<br />
standard Nalge Corporation and are pre-leached and<br />
pre-treated for increased product stability and purity<br />
■ High-purity acids and ASTM Type I water used in<br />
all manufacturing, as reported on the Certificate<br />
of Analysis<br />
■ Traceability directly to NIST standard reference<br />
materials, not independent sources or secondary<br />
NIST SRMs and reported on the Certificate<br />
of Analysis<br />
■ Wet assays on all multi-element products via<br />
standard, accepted wet methods and traceable<br />
directly to NIST SRM to +/-0.5% of true value<br />
and reported on the Certificate of Analysis<br />
■ All solutions tested and confirmed for the absence<br />
of interfering anions, e.g. chloride, bromide, etc.<br />
■ Twelve months guaranteed stability +/-0.5% for<br />
all major analytes for all products<br />
209
Standards<br />
PerkinElmer Pure Plus Standards for ICP-MS<br />
Inductively Coupled Plasma – MS Standards<br />
Detection Limit Standards<br />
ELAN DRC Sensitivity/Detection Limit Solution<br />
For use with ELAN DRC/DRC plus /DRC II. Not for use with the<br />
ELAN DRC-e.<br />
Matrix/Vol. Concentration of Element Part No. Each (€)<br />
0.5% HNO 3 /250 mL 1 μg/L Barium N8125034 63<br />
1 μg/L Beryllium<br />
1 μg/L Calcium<br />
1 μg/L Cerium<br />
1 μg/L Cobalt<br />
1 μg/L Indium<br />
1 μg/L Iron<br />
1 μg/L Lead<br />
1 μg/L Magnesium<br />
1 μg/L Potassium<br />
1 μg/L Rhodium<br />
1 μg/L Sodium<br />
1 μg/L Uranium<br />
ELAN 6100 Detection Limit Solution<br />
For use with the ELAN 9000/6100/DRC-e.<br />
Matrix/Vol. Concentration of Element Part No. Each (€)<br />
1% HNO 3 /250 mL 10 μg/L Beryllium N8125031 63<br />
10 μg/L Cobalt<br />
10 μg/L Indium<br />
10 μg/L Uranium<br />
ELAN 5000 Detection Limit Solution<br />
Matrix/Vol. Concentration of Element Part No. Each (€)<br />
2% HNO 3 /100 mL 10 μg/L Beryllium N8122017 63<br />
10 μg/L Cobalt<br />
10 μg/L Germanium<br />
10 μg/L Indium<br />
10 μg/L Thallium<br />
10 μg/L Uranium<br />
Instrument Calibration Standards<br />
ELAN DRC/DRC plus /DRC II Solution Kit<br />
A complete set of setup, test, and calibration standards<br />
for ELAN DRCs.<br />
Includes: Part No. Each (€)<br />
2 x 1000 mL of Setup/Stability/Masscal Solution N8125035 89<br />
2 x 250 mL of Wash Solution N8125033 37<br />
1 x 250 mL of Sensitivity/Detection Limit Solution N8125034 63<br />
1 x 100 mL of Methanol Blank Solution N8125037 60<br />
1 x 100 mL of Chromium in Methanol Solution N8125038 60<br />
Part No.<br />
Each (€)<br />
N8120541 318<br />
ELAN DRC Setup/Stability/Masscal Solution<br />
For use with ELAN DRC/DRC plus /DRC II. Not for use with the<br />
ELAN DRC-e.<br />
Matrix/Vol. Concentration of Element Part No. Each (€)<br />
0.5% HNO 3 /1000 mL 1 μg/L Aluminum N8125035 89<br />
10 μg/L Barium<br />
1 μg/L Cadmium<br />
1 μg/L Cerium<br />
1 μg/L Chromium<br />
1 μg/L Copper<br />
1 μg/L Indium<br />
1 μg/L Lead<br />
1 μg/L Magnesium<br />
1 μg/L Manganese<br />
1 μg/L Rhodium<br />
1 μg/L Thorium<br />
ELAN 9000/6100 Solution Kit<br />
For use with the ELAN 9000/6100. A complete set of setup,<br />
test, and calibration standards.<br />
Includes: Part No. Each (€)<br />
2 x 1000 mL of Setup/Stability/Masscal Solution N8125030 63<br />
1 x 125 mL of Dual-Detector Calibration Solution N8125032 50<br />
1 x 500 mL of Wash Solution N8122038 45<br />
1 x 250 mL of Detection Limit Solution N8125031 63<br />
ELAN 9000/6100 Setup/Stability/Masscal Solution<br />
For use with the ELAN 9000/6100/DRC-e.<br />
Matrix/Vol. Concentration of Element Part No. Each (€)<br />
1% HNO 3 /1000 mL 10 μg/L Barium N8125030 63<br />
10 μg/L Cadmium<br />
10 μg/L Cerium<br />
10 μg/L Copper<br />
10 μg/L Indium<br />
10 μg/L Lead<br />
10 μg/L Magnesium<br />
10 μg/L Rhodium<br />
10 μg/L Uranium<br />
ELAN 9000/6X00 Dual-Detector Calibration Solution<br />
For use with the ELAN 9000/6100/DRC-e.<br />
Part No.<br />
Each (€)<br />
N8120522 292<br />
Matrix/Vol. Concentration of Element Part No. Each (€)<br />
1% HNO 3 /100 mL 200 μg/L Cadmium N8125032 50<br />
200 μg/L Copper<br />
200 μg/L Lead<br />
200 μg/L Magnesium<br />
200 μg/L Rhodium<br />
210
Standards<br />
PerkinElmer Pure Plus Standards for ICP-MS<br />
ELAN 6000/5000 Plasma Setup Solution<br />
Multi-Element Calibration Standard 3<br />
Matrix/Vol. Concentration of Element Part No. Each (€)<br />
2% HNO 3 /1000 mL 10 μg/L Barium N8122014 88<br />
10 μg/L Cadmium<br />
10 μg/L Cerium<br />
10 μg/L Copper<br />
10 μg/L Germanium<br />
10 μg/L Lead<br />
10 μg/L Magnesium<br />
10 μg/L Rhodium<br />
10 μg/L Scandium<br />
10 μg/L Terbium<br />
10 μg/L Thallium<br />
Multi-Element Standards<br />
Designed to contain virtually every element in the mass<br />
spectrum for concentration checks.<br />
Multi-Element Calibration Standard 1<br />
Matrix/Vol. Concentration of Element Part No. Each (€)<br />
2% HNO 3 /100 mL 10 μg/mL Beryllium N9300231 152<br />
10 μg/mL Bismuth<br />
10 μg/mL Cerium<br />
10 μg/mL Cobalt<br />
10 μg/mL Indium<br />
10 μg/mL Lead<br />
10 μg/mL Magnesium<br />
10 μg/mL Nickel<br />
10 μg/mL Uranium<br />
Multi-Element Calibration Standard 2<br />
Matrix/Vol. Concentration of Element Part No. Each (€)<br />
5% HNO 3 /100 mL 10 μg/mL Cerium N9300232 254<br />
10 μg/mL Dysprosium<br />
10 μg/mL Erbium<br />
10 μg/mL Europium<br />
10 μg/mL Gadolinium<br />
10 μg/mL Holmium<br />
10 μg/mL Lanthanum<br />
10 μg/mL Lutetium<br />
10 μg/mL Neodymium<br />
10 μg/mL Praseodymium<br />
10 μg/mL Samarium<br />
10 μg/mL Scandium<br />
10 μg/mL Terbium<br />
10 μg/mL Thorium<br />
10 μg/mL Thulium<br />
10 μg/mL Ytterbium<br />
10 μg/mL Yttrium<br />
Matrix/Vol. Concentration of Element Part No. Each (€)<br />
5% HNO 3 /100 mL 10 μg/mL Aluminum N9300233 381<br />
10 μg/mL Arsenic<br />
10 μg/mL Barium<br />
10 μg/mL Beryllium<br />
10 μg/mL Bismuth<br />
10 μg/mL Cadmium<br />
10 μg/mL Calcium<br />
10 μg/mL Cesium<br />
10 μg/mL Chromium<br />
10 μg/mL Cobalt<br />
10 μg/mL Copper<br />
10 μg/mL Gallium<br />
10 μg/mL Indium<br />
10 μg/mL Iron<br />
10 μg/mL Lead<br />
10 μg/mL Lithium<br />
10 μg/mL Magnesium<br />
10 μg/mL Manganese<br />
10 μg/mL Mercury**<br />
10 μg/mL Nickel<br />
10 μg/mL Potassium<br />
10 μg/mL Rubidium<br />
10 μg/mL Selenium<br />
10 μg/mL Silver<br />
10 μg/mL Sodium<br />
10 μg/mL Strontium<br />
10 μg/mL Thallium<br />
10 μg/mL Uranium<br />
10 μg/mL Vanadium<br />
10 μg/mL Zinc<br />
** Mercury is supplied as a separate solution due to incompatibility<br />
with other elements.<br />
Multi-Element Calibration Standard 3 –<br />
Without Mercury<br />
Contains all the of the elements found in the standard<br />
Multi-Element Calibration Standard 3, excluding Mercury.<br />
Matrix/Vol. Part No. Each (€)<br />
5% HNO3/100 mL N9301720 343<br />
Multi-Element Calibration Standard 4<br />
Matrix/Vol. Concentration of Element Part No. Each (€)<br />
10% HCL /100 mL 10 μg/mL Antimony N9300234 165<br />
10 μg/mL Gold<br />
10 μg/mL Hafnium<br />
10 μg/mL Iridium<br />
10 μg/mL Palladium<br />
10 μg/mL Platinum<br />
10 μg/mL Rhodium<br />
10 μg/mL Ruthenium<br />
10 μg/mL Tellurium<br />
10 μg/mL Tin<br />
Standards Inductively Coupled Plasma – MS<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
211
Standards<br />
PerkinElmer Pure Plus Standards for ICP-MS<br />
Inductively Coupled Plasma – MS Standards<br />
Multi-Element Calibration Standard 5<br />
Matrix/Vol. Concentration of Element Part No. Each (€)<br />
H 2 O with trace 10 μg/mL Boron N9300235 228<br />
of HF /100 mL 10 μg/mL Germanium<br />
10 μg/mL Molybdenum<br />
10 μg/mL Niobium<br />
10 μg/mL Phosphorus<br />
10 μg/mL Rhenium<br />
10 μg/mL Silicon<br />
10 μg/mL Sulfur<br />
10 μg/mL Tantalum<br />
10 μg/mL Titanium<br />
10 μg/mL Tungsten<br />
10 μg/mL Zirconium<br />
Performance Verification Standards<br />
Methanol Blank Solution<br />
For DRC mode performance verification.<br />
Matrix/Vol. Part No. Each (€)<br />
1% Semiconductor Grade/100 mL N8125037 60<br />
Chromium in Methanol Solution<br />
For DRC mode performance verification.<br />
Matrix/Vol. Concentration of Element Part No. Each (€)<br />
1% Semiconductor 10 μg/L Chromium N8125038 60<br />
Grade Methanol/<br />
100 mL<br />
Selenium Solution<br />
For use with DRC-e.<br />
Matrix/Vol. Concentration of Element Part No. Each (€)<br />
5% HNO 3 /250 mL 10 μg/L Selenium N8125039 86<br />
Smart Tune Standards<br />
SmartTune Solution for Standard ELANs/DRC-e<br />
Matrix/Vol. Concentration of Element Part No. Each (€)<br />
1% HNO 3 /1000 mL 10 μg/L Barium N8125040 90<br />
10 μg/L Beryllium<br />
10 μg/L Cerium<br />
10 μg/L Cobalt<br />
10 μg/L Indium<br />
10 μg/L Magnesium<br />
10 μg/L Lead<br />
10 μg/L Rhodium<br />
10 μg/L Uranium<br />
SmartTune Solution for DRC/DRC plus /DRC II<br />
Matrix/Vol. Concentration of Element Part No. Each (€)<br />
0.5% HNO 3 /1000 mL 10 μg/L Barium N8125041 90<br />
1 μg/L Beryllium<br />
1 μg/L Cerium<br />
1 μg/L Cobalt<br />
1 μg/L Indium<br />
1 μg/L Iron<br />
1 μg/L Lead<br />
1 μg/L Magnesium<br />
1 μg/L Thorium<br />
1 μg/L Uranium<br />
Wash Standards<br />
ELAN DRC Wash Solution<br />
Matrix/Vol. Part No. Each (€)<br />
0.5% HNO 3 /250 mL N8125033 37<br />
ELAN 9000/6X00/DRC-e Wash Solution<br />
Not for use with ELAN DRC/DRC plus /DRC II.<br />
Matrix/Vol. Part No. Each (€)<br />
1% HNO 3 /500 mL N8122038 45<br />
212
PerkinElmer is the acknowledged global leader in Inductively<br />
Coupled Plasma Optical Emission Spectroscopy (ICP-OES),<br />
helping you advance research and development, control<br />
product quality and improve the environment.<br />
The PerkinElmer ® Optima family of ICP-OES instruments<br />
is recognized worldwide as the preferred choice to solve your<br />
application requirements. Whether your requirements are for<br />
high performance and productivity or high performance and<br />
analytical flexibility, the Optima family can meet your needs.<br />
And each instrument is backed by the renowned service and<br />
support of PerkinElmer.<br />
Inductively Coupled Plasma – OES
Inductively Coupled Plasma – OES<br />
QUICK-FIND INDEX Page #<br />
Air and Gas Accessories 216<br />
Blower and Vent Assembly 217<br />
Baffled Cyclonic Spray<br />
Chambers 225<br />
Concentric Nebulizers 221<br />
Cooling Systems/Chillers 217<br />
Cyclonic Spray Chambers 225<br />
Demountable Quartz Torches 227<br />
GemCone Nebulizers 222<br />
GemTip Crossflow II Nebulizers 223<br />
Injector Support Adapters 220<br />
Injectors 220<br />
Peristaltic Pump Tubing 224<br />
Quick-Change Torch Modules 227<br />
RF Load Coils 219<br />
Ryton Scott Spray Chambers 226<br />
Standards 231<br />
Torch Replacement Parts 228<br />
Ultrasonic Nebulizers 221<br />
PerkinElmer offers a wide selection of superior quality products designed to work with<br />
your PerkinElmer instruments. Our precision-designed products deliver the peace of<br />
mind that comes from knowing that you’ll get the results you need.<br />
The Quick Find Index to the left will help you find products fast. For your convenience,<br />
products are alphabetized by category, sub-category, and family. There is also a more<br />
complete Alphabetical INDEX on page 429 and a Part Number INDEX on page 407.<br />
Demountable Quartz Torches<br />
Cooling Systems/Chillers<br />
Nebulizers<br />
PerkinElmer’s demountable design uses one piece of quartz<br />
tubing for plasma and auxiliary gas flow. They are available<br />
in a range of styles from 0-3 Slots, depending on your<br />
instrument and application needs. From organic solvents<br />
to aqueous solutions, there is a torch designed to meet<br />
your need.<br />
Page 227<br />
Water Cooling Systems (Chillers) provide clean, reliable<br />
temperature controlled fluid for open tanks or closed loop<br />
cooling. They are ideal for many routine process cooling<br />
needs. They feature convenient “one-touch” temperature<br />
control, bright LED readouts and audible and visual alarms.<br />
Page 217<br />
PerkinElmer offers a wide selection of nebulizers for use<br />
with your Optima. From our exclusive GemCone and GemTip<br />
Crossflow II designs to standard concentric and ultrasonic<br />
nebulizers, you can choose the option that best fits your<br />
instrument and your analysis.<br />
Page 221<br />
Spray Chambers<br />
The spray chamber is responsible for filtering the sample<br />
mist to permit the appropriate droplet size distribution to<br />
reach the plasma. PerkinElmer offers a large selection of<br />
Cyclonic, Baffled Cyclonic and Ryton Scott models. Cyclonic<br />
and Baffled Cyclonic models are available in Standard,<br />
O-Ring Free and HF Resistant versions.<br />
Page 225
The Optima Family Offers the<br />
Performance and Productivity<br />
to Meet Your Application Requirements<br />
The difference is in the design.<br />
Optima 5300 DV<br />
Building on the success of the<br />
Optima TM , the world’s most<br />
popular ICP family:<br />
■ CCD array detectors provide fast<br />
and accurate performance<br />
■ High-resolution spectrometers<br />
provide easier method development<br />
and greater accuracy<br />
■ Exceptional reliability with a integrated<br />
solid-state RF generator<br />
■ Patented Dual-view optical system<br />
ensures the widest working range<br />
■ Stabilized optical systems eliminate<br />
peak profiling and searching, ensuring<br />
exceptional long-term stability<br />
■ Enhanced sample throughput and<br />
performance with simultaneous<br />
background correction<br />
■ Superior optics, excellent RF stability,<br />
and a thermostatted sample<br />
compartment make it easy to meet<br />
U.S. E.P.A. and DIN regulations<br />
■ A full line of sampling accessories<br />
There has never been a better<br />
time to achieve greater ICP-OES<br />
productivity and performance.<br />
Select from the models below<br />
to choose the Optima that is<br />
right for your needs.<br />
Optima 2100 DV<br />
With the performance and reliability<br />
found in simultaneous systems and the<br />
flexibility inherent to conventional ICPs,<br />
the Optima 2100 DV is revolutionizing<br />
ICP Optical Emission Spectrometry. The<br />
Optima 2100 DV Charge-coupled Device<br />
(CCD) ICP system brings advanced<br />
technology to the entry level ICP market.<br />
The Optima 2100 DV is the ideal solution<br />
for research and quality assurance<br />
laboratories that have a wide variety of<br />
samples and lower frequency of analysis.<br />
Features:<br />
■ CCD detector allows you to collect a complete<br />
simultaneous analyte spectrum at speeds that<br />
far exceed conventional systems<br />
■ Outstanding spectrometer design for superior<br />
results, detection limits and precision<br />
■ Eliminates the need for inaccurate analyte peak<br />
search routines and slow, multiple background reads<br />
■ Automatic dual viewing (DV) ensures the lowest<br />
detection limits and the widest working ranges.<br />
Optima 5X00 DV Series<br />
The Optima 5X00 DV ICP-OES offers<br />
the performance required to maximize<br />
productivity. While other simultaneous<br />
ICPs claim “speed”, only the Optima<br />
5X00 DV Series has the optimized design<br />
required to ensure accuracy, improve<br />
method development, and consistently<br />
deliver the correct answer. The system is<br />
ideal for laboratories with moderate to<br />
heavy loads of difficult samples.<br />
Features:<br />
■ Enhanced real-time graphics and FIAS control<br />
allows transient measurements<br />
■ The SCD detector provides fast and<br />
accurate performance<br />
■ Exclusive high-resolution mode provides easier<br />
method development and greater accuracy<br />
■ Exceptional reliability with a second-generation<br />
integrated solid-state RF generator<br />
■ Thermostatted optical system eliminates peak profiling<br />
and searching, ensuring exceptional long-term stability<br />
Optima 5300V<br />
The Optima 5300V offers a classic vertical<br />
torch configuration that minimizes salt<br />
and carbon build-up, thus minimizing<br />
maintenance worries. This new<br />
application-focused Optima system is<br />
designed specifically to meet the needs<br />
of oil analysis programs and metallurgical<br />
and geological laboratories. The robust<br />
sample introduction system, with its<br />
efficient sample transport, makes<br />
analyzing these samples fast and easy.<br />
The 5300V can meet the challenges for<br />
the most demanding samples requiring<br />
high precision and accuracy.<br />
Features:<br />
■ Easy access to the sample introduction system<br />
■ The oils unit is supplied with a glass cyclonic spray<br />
chamber and a low-flow GemCone nebulizer. It is<br />
also supplied with a 1.2 mm Alumina injector.<br />
■ The HF resistant unit is supplied with a PEEK cyclonic<br />
spray chamber and a high-flow, HF resistant GemCone<br />
nebulizer. This unit is supplied with a standard 2.0 mm<br />
Alumina injector.<br />
215
Accessories for ICP–OES<br />
Autosampler, FIAS, and FIMS Supplies and Laboratory Products<br />
Autosampler, FIAS, and FIMS Supplies and Accessories for ICP-OES<br />
Please see pages 8-10 for our full selection of Autosampler Sample Trays, Sample Vessels, Probes, Tubing, and Accessories.<br />
Please see pages 21-28 for our full selection of Supplies and Accessories for FIAS and FIMS.<br />
Accessories for ICP–OES<br />
Air and Gas Accessories<br />
Air and Water Filters<br />
Description ICP Model Part No. Each (€)<br />
Air Filter Assembly for the Instrument Air Supply Optima TM 2X00/4X00/5X00 N0770198 459<br />
Air Filter and Regulator Kit for the Instrument Air Supply Optima 3X00 XL/3X00 DV 00470652 555<br />
includes Type A82 Balston Air Filter Gas Regulator, and Fittings<br />
Filter Element for the Pre-Final Filter Optima 2X00/3X00/4X00/5X00 09907122 12<br />
for Optima Axial and Dual-View Systems, for the Shear Gas<br />
Filter Element for the Final Filter Optima 2X00/3X00/4X00/5X00 09923464 19<br />
for Optima Axial and Dual-View Systems, for the Shear Gas<br />
Filter Cartridge Element for Type A82 Balston Air Filter – Optima 2X00/3X00/4X00/5X00 N0582251 42<br />
includes Argon and Nitrogen Filters<br />
Air Filter for the Fan of the Main Power Supply Optima 2X00/3X00/4X00/5X00 09995098 7<br />
Air Filter for the RF Generator Inlet Optima 2X00/4X00/5X00 N0775220 20<br />
Air Filter for the RF Generator Inlet Optima 3X00 02509115 7<br />
Water Filter Optima 2X00/3X00/4X00/5X00 09904845 191<br />
Cartridge for the Water Filter Optima 2X00/3X00/4X00/5X00 09904846 43<br />
Inductively Coupled Plasma – OES<br />
Air Compressors<br />
Delivers 50 L/min. at 4.2 bar. Mounted on a 38 L tank built<br />
to ASME high-strength specifications.<br />
Power Requirement Part No. Each (€)<br />
115 V, 60 Hz 03030313 1194<br />
230 V, 50 Hz 03030314 1135<br />
Neon Correction System Assembly<br />
Includes complete neon replacement<br />
assembly for the Optima 2X00.<br />
Nitrogen Purge<br />
Gas Generator<br />
Part No. N0695470<br />
Part No.<br />
Each (€)<br />
B0810144 2762<br />
Nitrogen Purge Gas Generators<br />
Recommended as a source of high purity nitrogen purge<br />
gas. Nitrogen is separated from ambient air by a patented<br />
pressure swing adsorption process using a carbon molecular<br />
sieve (CMS) to differentially adsorb oxygen, carbon dioxide,<br />
water vapor, etc.<br />
Purity 99.99%<br />
Flow rate 5.0 L/min.<br />
Delivery Pressure 5 Bar (73 psig)<br />
Max. ambient temperature: 45 °C<br />
Min. ambient temperature: 5 °C<br />
Power<br />
Built-in<br />
Requirement Air Compressor Part No. Each (€)<br />
115 V, 60 Hz Yes N0695470<br />
115 V, 60 Hz No N0695468<br />
220 V, 50 Hz Yes N0695471 15800<br />
220 V, 50 Hz No N0695469 13800<br />
Accessories for the Nitrogen Purge Gas Generator<br />
Description Part No. Each (€)<br />
Filter, Air Compressor Inlet (pkg. 10) N0695472 54<br />
Filter Kit, Air N0695473 121<br />
Service Kit, Air Compressor N0695475 689<br />
Silencer, Exhaust N0695474 28<br />
216
Accessories for ICP–OES<br />
Laboratory Products<br />
Blower and Vent Assembly<br />
Cooling Systems<br />
Chillers/Recirculating Water Cooling Systems<br />
Water Cooling Systems (Chillers) provide clean, reliable<br />
temperature controlled fluid for open tanks or closed<br />
loop cooling. These Cooling Systems are ideal for many<br />
routine process cooling needs. They feature convenient<br />
“one-touch” temperature control and bright LED readouts<br />
which can be easily read, even from across the room – and<br />
let you check temperature set point and fluid flow rate<br />
and/or pressure quickly.<br />
For added operational safety, they also feature audible<br />
and visual alarms that alert you instantly when operating<br />
parameters exceed pre-set limits. There are even user<br />
adjustable high and low temperature limits to help prevent<br />
unauthorized set point changes plus built-in safeties to alert<br />
you to low fluid levels and thermal runaway.<br />
Other features include a calibration function that allows<br />
you to adjust the Chiller’s temperature display to match<br />
a traceable temperature standard and optional interfaces<br />
for various control functions, such as on/off and<br />
remote control.<br />
Chiller Coolant Mix<br />
Blower and Vent Assembly<br />
A venting system is required to<br />
remove fumes and vapors from the<br />
torch of ICP emission spectrometers.<br />
A vent is recommended for use<br />
over the power supply unit of<br />
most ICP spectrometers for<br />
removal of dissipated heat.<br />
Use exhaust venting to:<br />
Protect lab personnel from toxic vapors<br />
Protect your instrument from corrosive vapors<br />
Improve stability of the ICP torch<br />
Includes Exhaust Hood (03031910), Adapter (03031911),<br />
and Blower. Does not include ducting.<br />
PerkinElmer Service Engineers are<br />
not permitted to install this unit.<br />
Part No.<br />
03030406<br />
Each (€)<br />
1218<br />
Non-glycol coolant, which is made up of five 1/2 gallon<br />
bottles of distilled water and includes an additive to control<br />
black algae and other resistant strains.<br />
Part No. Each (€)<br />
N0776099 264<br />
Exhaust Hood<br />
Stainless steel. Part of Blower<br />
and Vent Assembly (03030406).<br />
Flexible Gas Hosing<br />
100 mm i.d. x 3 m hosing<br />
for RF generator exhaust vent.<br />
Fresh Air Kit<br />
Kit to attach generator air to<br />
fresh air services. Includes<br />
adapter, hose, and clamp.<br />
Part No.<br />
Part No.<br />
Each (€)<br />
N0691578 50<br />
Part No.<br />
Each (€)<br />
03031910 236<br />
Each (€)<br />
N0770434 459<br />
ICP Model Power Requirement Operating Temp. Flow Rate Part No. Each (€)<br />
Optima 2X00/4X00/5X00 208-230 V, 60 Hz, 8 A -15˚ to 40 ˚C 60 psi: 4.3 gpm/16.3 Lpm N0772026 4029<br />
Optima 2X00/4X00/5X00 240 V, 50 Hz, 8.5 A -15˚ to 40 ˚C 60 psi: 4.3 gpm/16.3 Lpm N0772025 4029<br />
Optima 3X00 120 V, 60 Hz, 13.1 A -5˚ to 40 ˚C 60 psi: 1 gpm/3.8 Lpm N0691883 3558<br />
Optima 3X00 240 V, 50 Hz, 7.3 A -5˚ to 40 ˚C 60 psi: 1 gpm/3.8 Lpm N0691884 3558<br />
Accessories for ICP-OES Inductively Coupled Plasma – OES<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
217
Sample Introduction<br />
Accessories for Sample Introduction<br />
Drain Assembly Components<br />
Drain Adapter Assembly<br />
Assembly includes the Ryton Scott Spray Chamber fitting<br />
and tubing to pump out the waste solution from the spray<br />
chamber. Assembly does not include peristaltic pump tubing.<br />
ICP Model Part No. Each (€)<br />
Protective and<br />
Cleaning Accessories<br />
Inductively Coupled Plasma – OES Sample Introduction<br />
Optima 2X00/4X00/5X00 N0680504 261<br />
Optima 3000/3000 SCR/3X00 RL N0690287 308<br />
Optima 3X00 DV/XL/3000 SCX N0690288 51<br />
Drain Assembly Accessories<br />
Description Part No. Each (€)<br />
15 Liter Carboy 09904991 112<br />
Drain Assembly Hardware for the Plasma 400 00473449 87<br />
Drain Cap Assembly for all Optima Series N0690271 398<br />
Elbow Drain Assembly for the 3X00 XL 09920262 3<br />
Drain Loop Assembly for the Plasma 400<br />
Dimensions Solutions Part No. Each (€)<br />
18 in. Aqueous Only 00470551 344<br />
30 in. Organic or Aqueous 00470608 344<br />
Drain Tubing for the Plasma 400<br />
Dimensions Color Solutions Part No. Each (€)<br />
9.5 mm i.d. x 12.7 mm o.d. Clear Aqueous 02506519 3<br />
9.5 mm i.d. x 12.7 mm o.d. Yellow Organic 02506532 3<br />
Pumped Drain Accessory for the Plasma 400<br />
Uses the extra channel of the peristaltic<br />
pump to pump the waste solution out<br />
of the spray chamber.<br />
Part No.<br />
Each (€)<br />
N0650230 402<br />
Argon Humidifier with Bypass Part No. N0775331<br />
Argon Humidifier with Bypass<br />
The Argon Humidifier is commonly used in ICP analyses<br />
of samples with very high dissolved solids concentration.<br />
Helping to prevent salt build-up inside the sample introduction<br />
system, the Argon Humidifier allows uninterrupted<br />
and maintenance-free operation. The Argon Humidifier<br />
combines ease of operation, high performance and safety.<br />
For use with Optima 2X00/4X00/5X00.<br />
The rugged and durable plastic casing enhances safety<br />
The built-in pressure indicator serves as a diagnostic so<br />
you will always know the sample introduction system is<br />
operating properly<br />
An easy-to-use bypass toggle allows you to take the Argon<br />
Humidifier off-line without disconnecting argon lines<br />
Maximum and minimum fill marks ensure that you are<br />
always operating under optimum conditions<br />
A rugged bubbling frit ensures maximum saturation<br />
of the argon<br />
Part No. Each (€)<br />
N0775331 2046<br />
218
Sample Introduction<br />
Accessories for Sample Introduction<br />
Eluo Nebulizer Cleaner<br />
Particle build-up in a nebulizer capillary and tip causes<br />
sample flow to be constricted, thereby reducing nebulizer<br />
efficiency and performance. Previously there was no simple<br />
way to effectively clean and unblock nebulizers. Now,<br />
blocked nebulizers can be safely and easily restored to<br />
optimum performance with a revolutionary new cleaning<br />
instrument – the Eluo. The Eluo is designed to efficiently<br />
deliver a cleanser through the nebulizer capillary to<br />
dislodge particle build-up and thoroughly clean<br />
the nebulizer.<br />
Cleaning your nebulizer is now a simple three step process:<br />
1. Fill your Eluo with Methanol.<br />
2. Insert your nebulizer, tip first, into the Eluo.<br />
3. Clean your nebulizer by pressing the Plunger down.<br />
Use the Eluo regularly to maintain nebulizer performance<br />
and prolong nebulizer life. The Eluo is effective for<br />
MEINHARD ® , MicroMist, and SeaSpray nebulizers.<br />
Sample Compartment Drip Tray,<br />
Optima 3000 and Optima 3000 XL<br />
An acid resistant drip tray that fits in<br />
the bottom of the sample compartment.<br />
Sample Shelf Liner<br />
An acid resistant tray that lines the<br />
sample shelf of the Optima 3000<br />
and Optima 3000 XL.<br />
Thermal Shield for Sample<br />
Compartment Optima 3000<br />
A thermal shield that separates<br />
the nebulizer and spray chamber<br />
from the plasma torch.<br />
Purge Components<br />
Ceramic Interface Cone<br />
The Ceramic Interface Cone for the Optima 3X00 XL and<br />
3000 SCX includes the Ceramic Cone, the Purge<br />
Window (09992731), and the clamp.<br />
The Ceramic Cone is used between<br />
the plasma and the spectrometer.<br />
Part No.<br />
N0690666<br />
Each (€)<br />
268<br />
Ceramic Purge Extension<br />
For the Optima 3000/3000 SCR/<br />
3X00 RL/4300V/5300V.<br />
Part No.<br />
Part No.<br />
Part No.<br />
Part No.<br />
Each (€)<br />
N0695233 52<br />
Each (€)<br />
N0691182 159<br />
Each (€)<br />
N0695219 69<br />
Part No.<br />
Each (€)<br />
N0775358 277<br />
Each (€)<br />
N0581455 459<br />
Purge Extension Windows<br />
The Axial View Purge Extension Window is a replaceable<br />
quartz window that slides into the purge extension between<br />
the torch and the optics. The Radial View Purge Extension<br />
Window Tube is a replaceable quartz tube that slides into the<br />
mount between the torch and the optics for the radial view.<br />
ICP Model View Part No. Each (€)<br />
Optima 2X00 Radial B0810377 429<br />
Optima 2X00/3X00 XL/3000 SCX Axial 09992731 77<br />
Optima 3000/3000 SCR/3X00 RL/ Radial N0581497 159<br />
4300V/5300V<br />
Optima 3X00 DV Axial B0066549 21<br />
Optima 3X00 DV (long tube) Radial N0691689 223<br />
Optima 3X00 DV (short tube) Radial N0690672 217<br />
Optima 4X00/5X00 Axial N0771116 59<br />
Optima 4X00DV/5X00DV Radial N0770322 185<br />
Plasma 400 Radial N0681234 281<br />
B1<br />
B2<br />
RF Load Coils<br />
RF Load Coils*<br />
Components Part No. Each (€)<br />
Radial Purge Extension Window for N0581497 159<br />
Optima 3000/3000 SCR/3X00<br />
RL/4300V5300V<br />
Ceramic Purge Extension for Optima N0581455 459<br />
3000/3000 SCR/3X00 RL/4300V<br />
5300V<br />
ICP Model Part No. Each (€)<br />
Optima 2X00/4X00/5X00 DV N0775300 346<br />
Optima 3X00 XL/3X00 DV N0690772 242<br />
Optima 3000/3000 SCR/3X00 RL N0690572 204<br />
(For instruments manufactured BEFORE 9/21/94)<br />
Optima 3000/3000 SCR/3X00 RL N0690668 495<br />
(For instruments manufactured AFTER 9/21/94)<br />
Optima 4300V/5300V N0771536 178<br />
Plasma 400 (Assembly includes Torch Bonnet) N0680212 255<br />
* Installation by PerkinElmer Service is required, but not included.<br />
RF Load Coil Accessories<br />
Description Part No. Each (€)<br />
Igniter Spark Gap Assembly N0680275 111<br />
for Type II Demountable Torch<br />
Nylon Igniter Standoff 09989859 1<br />
B1<br />
B2<br />
Sample Introduction Inductively Coupled Plasma – OES<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
219
Sample Introduction<br />
Injectors and Adapters<br />
Injectors<br />
Injector Support Adapters<br />
Inductively Coupled Plasma – OES Sample Introduction<br />
Alumina Injectors<br />
Alumina injectors are corrosion-resistant to all mineral acids<br />
including HF and aqua regia. They are also used with less<br />
volatile organic solvents, e.g., xylene. The 2.0 mm i.d.<br />
Alumina Injector is shipped standard with all PerkinElmer<br />
ICP-OES instruments. A variety of sizes are available as an<br />
alternative to the standard injector.<br />
ICP Model Dimensions Part No. Each (€)<br />
Optima 2X00/4X00/5X00 DV 0.80 mm i.d. N0775227 204<br />
Optima 2X00/4X00/5X00 DV 1.2 mm i.d. N0775228 204<br />
Optima 2X00/4X00/5X00 DV 2.0 mm i.d. N0775177 204<br />
Optima 3000/3000 SCR/ 0.85 mm i.d. N0582186 159<br />
3X00 RL/Plasma 400/400 WMA<br />
Optima 3000/3000 SCR/ 1.5 mm i.d. N0582185 159<br />
3X00 RL/Plasma 400/400 WMA<br />
Optima 3000/3000 SCR/ 2.0 mm i.d. N0582184 159<br />
3X00 RL/Plasma 400/400 WMA<br />
Optima 3X00 XL/3X00 DV/ 2.0 mm i.d. N0695362 166<br />
3000 SCX/4300V/5300V<br />
Optima 4300V/5300V 1.2 mm i.d. N0771531 164<br />
Quartz Injectors<br />
Quartz Injectors are designed for organic solvents and<br />
non-HF matricies. A variety of sizes are available as an<br />
alternative to the standard injector.<br />
ICP Model Dimensions Part No. Each (€)<br />
Optima 2X00/4X00/5X00 DV 0.80 mm i.d. N0775225 134<br />
Optima 2X00/4X00/5X00 DV 1.2 mm i.d. N0775226 134<br />
Optima 2X00/4X00/5X00 DV 1.6 mm i.d. N0775223 134<br />
Optima 2X00/4X00/5X00 DV 2.0 mm i.d. N0775014 134<br />
Optima 2X00/4X00/5X00 DV 3.0 mm i.d. N0775224 134<br />
Optima 3000/3000 SCR/ 1.2 mm i.d. N0681631 159<br />
3X00 RL/Plasma 400/400 WMA<br />
Optima 3000/3000 SCR/3X00 RL 1.6 mm i.d. N0695448 166<br />
Optima 3000/3000 SCR/3X00 RL 2.0 mm i.d. N0695441 166<br />
Optima 3X00 XL/3X00 DV/ 0.8 mm i.d. N0695461 166<br />
3000 SCX/4300V/5300V<br />
Optima 3X00 XL/3X00 DV/ 1.2 mm i.d. N0695460 166<br />
3000 SCX/4300V/5300V<br />
Optima 3X00 XL/3X00 DV/ 1.6 mm i.d. N0695449 166<br />
3000 SCX/4300V/5300V<br />
Optima 3X00 XL/3X00 DV/ 2.0 mm i.d. N0695442 159<br />
3000 SCX/4300V/5300V<br />
Plasma 400/400 WMA 1.6 mm i.d. 00473292 134<br />
Sapphire Injectors<br />
Sapphire injectors are ideal for silicon applications.<br />
ICP Model Dimensions Part No. Each (€)<br />
Optima 2X00/4X00/5X00 DV 2.0 mm i.d. N0775247 1052<br />
Optima 3000/3000 SCR/3X00 RL 2.0 mm i.d. N0695495 995<br />
Optima 3X00 XL/3X00 DV/ 2.0 mm i.d. N0695494 995<br />
3000 SCX/4300V/5300V<br />
Injector Support Adapters<br />
Spray<br />
ICP Model Chamber Part No. Each (€)<br />
Optima 2X00/4X00/5X00 DV All N0770603 319<br />
Optima 3000/3000 SCR/3X00 RL Ryton Scott N0695214 126<br />
Optima 3X00 XL/3X00 DV/ Ryton Scott N0695400 242<br />
3000 SCX<br />
Optima 3X00 XL/3X00 DV/ Cyclonic N0690780 242<br />
3000 SCX<br />
Optima 4300V/5300V (bottom) Cyclonic N0771526 284<br />
Optima 4300V/5300V (top) Cyclonic N0771527 121<br />
Plasma 400/400 WMA Ryton Scott N0582248 112<br />
Injector Support Adapter O-Ring Kits<br />
ICP Model Part No. Each (€)<br />
Optima 2X00/4X00/5X00 DV N0770438 13<br />
Optima 3000/3000 SCR/3X00 RL N0690269 25<br />
Optima 3X00 XL/3X00 DV/3000 SCX/ N0690769 25<br />
4300V/5300V<br />
Plasma 400/400 WMA N0580539 59<br />
(Includes O-Rings for the Type II Demountable Torch)<br />
Injector and Adapter for<br />
Optima 3X00 XL/3X00 DV/3000 SCX<br />
A<br />
B<br />
Components Part No. Each (€)<br />
2.0 mm i.d. Alumina Injector N0695362 166<br />
Injector Support Adapter N0695400 242<br />
A<br />
B<br />
220
Sample Introduction<br />
Nebulizers<br />
CETAC Ultrasonic Nebulizer<br />
The CETAC Ultrasonic Nebulizer expands the analytical<br />
capacity of your ICP-OES instrument by increasing your<br />
sample introduction efficiency. You can typically expect<br />
an improvement of detection limits by a factor of 10.<br />
The U-5000AT + Ultrasonic Nebulizer uses mechanical forces<br />
from an oscillating transducer to break a liquid sample<br />
stream into very small droplets with a relatively uniform<br />
droplet size. Because the formation of this fine aerosol is so<br />
efficient, a desolvation system consisting of a heated tube<br />
and a condenser is placed after the nebulization chamber<br />
to remove most of the water.<br />
The U-6000AT + allows direct analysis of organic solvents by<br />
ICP-OES. When the U-6000AT + is used, the green C 2 molecular<br />
bands are eliminated. This efficient desolvation system<br />
produces a robust plasma with minimal spectral interferences.<br />
Can be used with all PerkinElmer ICP and ICP-MS instruments.<br />
Includes one Ultrasonic Nebulizer and Cooling System.<br />
U-5000AT + Ultrasonic Nebulizer System<br />
Description Part No. Each (€)<br />
115 V 50/60 Hz N8120140 13800<br />
230 V 50/60 Hz N8120141 13800<br />
U-6000AT + Ultrasonic Nebulizer System<br />
Description Part No. Each (€)<br />
115 V 50/60 Hz N0691709 26400<br />
230 V 50/60 Hz N0691710 26400<br />
Replacement Parts:<br />
Description Part No. Each (€)<br />
Drain Tubing 02506516 1<br />
Drain Pump Tubing and Connector Kit N8122150 183<br />
Argon Carrier and Sample Tubing 02506517 1<br />
Transducer Assembly N8122161 933<br />
KALREZ ® O-Ring for Spray Chamber N8122162 561<br />
Concentric Nebulizers<br />
MEINHARD Nebulizers<br />
The MEINHARD ® concentric<br />
glass nebulizer reflects exacting<br />
standards in design and<br />
manufacturing. Its advantages<br />
include simplicity of design<br />
and operation, reproducible<br />
and self-aligning aerosol, and<br />
close fabrication control. They<br />
provide excellent sensitivity and precision for aqueous<br />
solutions and samples with few dissolved solids (less than<br />
1%). MEINHARD Nebulizers are self-aspirating and must<br />
be used with solutions containing hydrofluoric acid.<br />
PerkinElmer offers three types for ICP-OES, MEINHARD A,<br />
C, and K. All require an End Cap for use with Ryton Scott<br />
Spray Chambers. See End Cap product listing below for<br />
the correct part number.<br />
MEINHARD Model Application Part No. Each (€)<br />
Type A General Purpose 00472020 587<br />
Type C High Dissolved Solids 00472022 727<br />
Type K Reduced Flow, and Organics N0681574 918<br />
End Cap for GemCone TM<br />
and Concentric Glass Nebulizers<br />
ICP Model Part No. Each (€)<br />
Optima 2X00/3X00/4X00/5X00 N0680504 261<br />
MicroMist Nebulizers<br />
The MicroMist micro-uptake glass concentric nebulizer<br />
offers high performance for limited sample volumes.<br />
MicroMists with sample uptakes 0.2 - 0.6 mL/min. are fitted<br />
with an EzyFit connector with 1.3 mm o.d. x 0.50 mm i.d. x<br />
700 mm long sample tubing. MicroMists with sample uptakes<br />
0.05 - 0.1 mL/min. are fitted with an EzyFit connector with<br />
1.3 mm o.d. x 0.25 mm i.d. x 700 mm long sample tubing.<br />
All MicroMist Nebulizers offered by PerkinElmer are supplied<br />
with the EzyLok argon connector.<br />
MicroMist Nebulizers with 0.7 L/min. Ar Flow for<br />
Optima 2X00/3X00 XL/3X00 DV/3000 SCX/4X00/5X00<br />
Uptake Rate Part No. Each (€)<br />
0.6 mL/min. N0775346 590<br />
0.2 mL/min. N0775347 677<br />
0.1 mL/min. N0775348 677<br />
0.05 mL/min. N0775349 870<br />
Sample Introduction Inductively Coupled Plasma – OES<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
221
Sample Introduction<br />
Nebulizers<br />
GemCone Nebulizer<br />
Inductively Coupled Plasma – OES Sample Introduction<br />
MicroMist Nebulizer<br />
Part No. N0775343<br />
MicroMist Nebulizers with 1 L/min. Ar Flow<br />
for Optima 3000/3000 SCR/3X00 RL<br />
Uptake Rate Part No. Each (€)<br />
0.4 mL/min. N0775341 590<br />
0.2 mL/min. N0775342 677<br />
0.1 mL/min. N0775343 677<br />
0.05 mL/min. N0775344 870<br />
PEEK Mira Mist ® Nebulizer<br />
The Mira Mist fits regular spray chambers as a direct<br />
replacement for glass concentric nebulizers. Its features<br />
include standard pressure (45 psi), low sample flow,<br />
and enhanced parallel path design. The Mira Mist can<br />
operate on 0.2 to 2.5 mL/min. and can handle high levels<br />
of particulates in the sample. Use this nebulizer for analysis<br />
of aqueous samples on the Optima 2X00/4X00/5X00.<br />
ICP Model Part No. Each (€)<br />
Optima 2X00/4X00/5X00 N0775330 1071<br />
SeaSpray Nebulizer<br />
Part No. N0775340<br />
SeaSpray Nebulizers<br />
The SeaSpray Concentric Nebulizer is ideal for samples with<br />
high dissolved solids and offers outstanding nebulization<br />
efficiency for trace level analyses. It offers freedom from<br />
clogging while nebulizing solutions to the limit of<br />
solubility of most mineral salts, and conferring significant<br />
sensitivity gains.<br />
All SeaSpray Nebulizers listed are supplied with an EZT-075<br />
EzyFit connector (sample tube 0.75 mm i.d. x 1.3 mm o.d.).<br />
All SeaSpray Nebulizers offered by PerkinElmer are<br />
supplied with the EzyLok argon connector.<br />
Ar Flow<br />
Uptake<br />
Rate ICP Model Rate Part No. Each (€)<br />
0.7 L/min. Optima 2X00/3X00 XL/ 2 mL/min. N0775345 750<br />
3X00 DV/3000 SCX/<br />
4X00/5X00<br />
1 L/min. Optima 3000/ 2 mL/min. N0775340 750<br />
3000 SCR/3X00 RL<br />
GemCone High Dissolved Solids Nebulizer<br />
GemCone Low Flow Nebulizers<br />
High Solids GemCones<br />
are for samples with high<br />
dissolved solids (up to<br />
20%). GemCone Nebulizers<br />
require an End Cap for use<br />
with Ryton Scott Spray<br />
Chambers. Please see End<br />
Cap product listing below<br />
for the correct part number.<br />
Low Flow GemCones<br />
permit lower nebulizer<br />
gas flow rates, useful for<br />
spectral lines with high<br />
excitation energies and<br />
for providing a more<br />
robust plasma. GemCone<br />
Nebulizers require an End<br />
Cap for use with Ryton<br />
Scott Spray Chambers.<br />
Please see End Cap<br />
product listing below for<br />
the correct part number.<br />
ICP Model Part No. Each (€)<br />
2X00/4X00/5X00/ N0770358 434<br />
3X00 N0690671 638<br />
GemCone Sample Capillary Adapter<br />
Plastic fitting that connects the<br />
capillary sample tube to the nebulizer.<br />
End Cap for GemCone<br />
and Concentric Glass Nebulizers<br />
Part No.<br />
Each (€)<br />
N0690670 638<br />
Part No.<br />
Each (€)<br />
N0371505 13<br />
ICP Model Part No. Each (€)<br />
Optima 2X00/3X00/4X00/5X00 N0680504 261<br />
222
Sample Introduction<br />
Nebulizers<br />
GemTip Crossflow Nebulizer<br />
GemTip TM Crossflow II Nebulizer<br />
for the Optima 2X00/4X00/5X00<br />
Part No. N0770546<br />
GemTip Crossflow II Nebulizers<br />
Excellent general purpose nebulizer for the analysis of<br />
strong mineral acids (including HF) and samples with less<br />
than 5% dissolved solids. It can routinely handle 50% (v/v)<br />
solutions of HCl, HNO 3 , H 2 SO 4 , H 3 PO 4 , 20% (v/v) HF and<br />
30% (v/v) NaOH. Up to 20% NaCl can be aspirated by the<br />
nebulizer for 1 hour without clogging. Uses chemically<br />
resistant GemTips made of sapphire and ruby in a<br />
Ryton End Cap for maximum chemical resistance.<br />
ICP Model Part No. Each (€)<br />
Optima 2X00/4X00/5X00 N0770546 593<br />
Optima 3X00 N0680503 504<br />
GemTip Crossflow II Nebulizer and End Cap Retrofit Kit<br />
This kit includes the GemTip Crossflow II Nebulizer, End Cap<br />
Assembly and the fittings required to install the nebulizer<br />
for the first time on the Plasma<br />
40/400, Plasma 1000/2000, and<br />
Optima 3X00 instruments.<br />
Part No.<br />
N0680610<br />
Each (€)<br />
599<br />
GemTip Crossflow Nebulizer II<br />
Tip Kits Part No. N0690676<br />
GemTip Crossflow<br />
Nebulizer Tip Kits<br />
Includes a clear sapphire sample<br />
tip (0.012 in. i.d.) and a red ruby<br />
argon tip (0.009 in. i.d.). The tips<br />
are constructed of PEEK with the<br />
gem inserts noted for maximum<br />
corrosion resistance. Used in all<br />
GemTip Crossflow Nebulizers.<br />
Description Part No. Each (€)<br />
GemTip Crossflow II N0690676 176<br />
GemTip Crossflow N0580624 112<br />
GemTip Crossflow O-Ring Kit<br />
GemTip Crossflow II Nebulizer<br />
for the Optima 3X00<br />
Part No. N0680503<br />
Includes two of 09902001, two of 09902033, three of<br />
09902151, one of 09921003, and 3 cm of Teflon sample tubing.<br />
Part No.<br />
Each (€)<br />
N9300067 33<br />
GemTip Crossflow II Nebulizer Replacement Parts<br />
1<br />
2<br />
3<br />
4<br />
*<br />
5<br />
6<br />
7<br />
8<br />
9<br />
10<br />
11<br />
a<br />
b<br />
12<br />
13<br />
14<br />
15<br />
16<br />
17<br />
18<br />
2<br />
Description Part No. Each (€)<br />
Screws (two) – Knurled 00473539 15<br />
Ring 00473543 28<br />
O-Ring, 18W, 1-3/8 i.d., 1-5/8 o.d. 09902033 5<br />
Fitting Reducer 1/8 TBG, 1/4 Port 09903471 12<br />
These parts are included with item 4<br />
Ferrule – TBG 1/8 Tefzel 09920515 9<br />
Nut – TBG Flanged 0.0625 PEEK 09920546 8<br />
Nut – TBG Flanged 0.125 PEEK 09920545 8<br />
Ferrule – TBG 1/16 Tefzel 09920518 9<br />
Tubing, 0.032 i.d. x 0.016 Wall, 09985708 7<br />
Teflon ® (per foot)<br />
Tubing, 0.06 i.d. x 1/8 o.d., 02506483 3<br />
Teflon (per foot )<br />
Tip Kit for Crossflow Nebulizer N0690676 176<br />
Argon and Sample tip (one each)<br />
Argon Tip (Red)<br />
Sample Tip (Clear)<br />
End Cap Crossflow Nebulizer N8122239 201<br />
O-Rings (two) 0.126 i.d., 09921045 1<br />
0.040 WD, Viton<br />
Tubing (10 feet ) – 0.023 i.d., Clear 09908265 29<br />
Nut – Hex – 0.250 TBG BRS 09903199 1<br />
Ferrule – Back 1/4 BRS 09903104 1<br />
Ferrule – Front 1/4 BRS 09903103 1<br />
Insert – Tubing 00473578 13<br />
Barbed coupler – Not Shown 09920186 4<br />
13<br />
11 b<br />
8<br />
6<br />
9<br />
14<br />
3 12<br />
1<br />
13<br />
11 a<br />
5<br />
17 16 15<br />
4<br />
7<br />
*<br />
18<br />
*<br />
*<br />
10<br />
Sample Introduction Inductively Coupled Plasma – OES<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
223
Sample Introduction<br />
Peristaltic Pump Supplies and Accessories<br />
Inductively Coupled Plasma – OES Sample Introduction<br />
Peristaltic Pump<br />
Gilson ® 4-Channel Peristaltic Pump<br />
The Gilson 4-Channel Peristaltic Pump can be used<br />
with the Optima Series of ICP spectrometers. The<br />
Pump requires, but does not include, the Gilson Pump<br />
Adapter Cable (N0690262) for computer control by the<br />
Optima 3X00. No computer control of the Pump is<br />
available for the Optima 2X00/4X00/5X00. All Optima<br />
2X00/4X00/5X00 spectrometers are Part No. Each (€)<br />
supplied with a 3-channel peristaltic<br />
pump as standard equipment.<br />
N8122126 3877<br />
Gilson Pump Adapter Cable<br />
Connects the Gilson Pump to the<br />
Optima 3X00 for computer control<br />
of the pump.<br />
On-line Internal Standard Addition Kit<br />
for the Optima Series<br />
This kit uses the third channel of the Optima pump and<br />
allows the automatic addition of an internal standard to<br />
standards, blanks, and samples.<br />
It includes peristaltic pump tubing<br />
(N0695476) and FIAS fittings.<br />
Part No.<br />
N0690673<br />
Each (€)<br />
912<br />
Peristaltic Pump Head<br />
For use with Optima 2X00/4X00/5X00.<br />
Roller Material Part No. Each (€)<br />
Plastic (Delrin) N0690284 402<br />
Stainless Steel N0690360 1046<br />
Peristaltic Pump Shelf for the Optima 3000 Family<br />
An optional shelf for the peristaltic pump that hangs from<br />
the sample shelf. Useful if extra space<br />
is required on the sample shelf.<br />
Part No. Each (€)<br />
N0690639 344<br />
Peristaltic Pump Tubing<br />
Nebulizer Capillary Tubing<br />
Part No.<br />
Each (€)<br />
N0690262 87<br />
10 ft. (3 m) length of polyethylene tubing, 0.023 in. (0.6 mm)<br />
i.d. x 0.038 in. (0.97 mm) o.d. Tubing is used between the<br />
nebulizer and the pump tubing. For use<br />
with GemTip Crossflow and GemCone<br />
High Dissolved Solids Nebulizers.<br />
Part No.<br />
09908265<br />
Each (€)<br />
29<br />
Peristaltic Pump Tubing<br />
Peristaltic pump tubing comes in a package of 12,<br />
30 cm (1 foot) lengths, unless otherwise noted.<br />
Dimensions Color Specifications Part No. Each (€)<br />
0.76 mm i.d. Black Standard PVC Peristaltic 09908587 59<br />
Pump Tubing, resistant to<br />
most mineral acids.<br />
1.14 mm i.d.* Red PVC Tubing for use with N0680375 99<br />
pump drain accessory,<br />
for 2 mL/min. flow rate.<br />
1.14 mm i.d. Red Solvent Flex Tubing, N0680376 92<br />
specially formulated PVC<br />
for use with kerosene<br />
or xylene. Not recommended<br />
for use with MIBK (methyl<br />
isobutyl ketone). For use<br />
with pump drain accessory.<br />
0.76 mm i.d. Black Solvent Flex Tubing, 00473550 59<br />
specially formulated PVC<br />
for use with kerosene<br />
or xylene. Not recommended<br />
for use with MIBK (methyl<br />
isobutyl ketone).<br />
0.76 mm i.d. Black Silicone Manifold Tubing, 00473552 88<br />
for use with organic<br />
solvents including MIBK.<br />
Not recommended for use<br />
with kerosene or xylene.<br />
1.14 mm i.d. Red Silicone Manifold Tubing, N0691595 149<br />
for use with organic<br />
solvents including MIBK.<br />
Not recommended for use<br />
with kerosene or xylene.<br />
For use with pump<br />
drain accessory.<br />
*Includes 6 in. (152 cm) PTFE Tubing (09985708) to adapt 0.045 in.<br />
(1.14 mm) i.d. tubing to the Nebulizer Capillary Tubing (09908265).<br />
PTFE Tubing<br />
1 ft (0.3 m) length of PTFE tubing, 0.79 mm o.d. x<br />
0.41 mm i.d. Used to connect capillary tubing (09908265)<br />
to GemTip Crossflow Nebulizers, and<br />
to larger i.d. Peristaltic Pump Tubing. Part No. Each (€)<br />
Teflon Tubing<br />
09985708 7<br />
1 meter length of Teflon tubing, 1 mm i.d. For delivering<br />
and pumping out the sample. Used with larger i.d. solvent<br />
flex tubing. Also used with<br />
the pumped drain assembly.<br />
Part No. Each (€)<br />
B0029792 2<br />
224
Sample Introduction<br />
Spray Chambers<br />
Cyclonic Spray Chamber<br />
The spray chamber is an integral part of the sample<br />
introduction system responsible for filtering the sample<br />
mist to permit the appropriate droplet size distribution to<br />
reach the plasma. The cyclonic spray chamber relies on<br />
momentum to efficiently and quickly remove the larger<br />
droplets from the sample mist decreasing any opportunity<br />
for occlusion or agglomeration of the smaller droplets.<br />
The result is higher efficiency, better precision, and<br />
faster washouts than other spray chamber designs.<br />
Save time and expense<br />
1. Decreased sample introduction system installation and<br />
optimization time due to the preset nature of the spray<br />
chamber/nebulizer combination.<br />
2. More samples per hour due to minimal dead volume<br />
and efficient draining.<br />
Unique design characteristics<br />
1. The nebulizer port is oversized so that sample solution<br />
cannot build up around the nebulizer as it will in other<br />
cyclonic designs. This translates to less carryover,<br />
faster washout times, and greater productivity from<br />
your Optima.<br />
2. The nebulizer port angle is tightly controlled so that the<br />
nebulizer mist impacts on the same chamber wall area<br />
in each and every spray chamber. The angle of incidence<br />
is critical in determining the efficiency of large<br />
droplet removal.<br />
3. A trace metal free plastic nebulizer adapter is employed<br />
to fix the depth of nebulizer insertion at the optimal<br />
position. Because of this, there is no need for an operator<br />
to move the nebulizer in and out of the port in an effort<br />
to locate the “sweet spot”.<br />
4. Each spray chamber incorporates a precisely machined<br />
ridge along the inside top of the spray chamber. Both the<br />
angle and depth of the ridge are critical to performance.<br />
The result is efficient draining of sample waste and the<br />
elimination of large droplets being swept into the plasma.<br />
This eliminates the periodic “spiking” that adversely<br />
affects precision and fosters faster washout times.<br />
Cyclonic Spray Chambers<br />
Standard and O-Ring Free Glass Cyclonic Spray Chambers<br />
can be used with either GemCone or Concentric Glass<br />
Nebulizers. HF Resistant Cyclonic Spray Chambers should<br />
be used with GemCone, SeaSpray, or MicroMist nebulizers.<br />
ICP Model Type Part No. Each (€)<br />
Optima 2X00/4X00/5X00 Standard N0776052 791<br />
Optima 2X00/4X00/5X00 O-Ring Free N0775351 584<br />
Optima 2X00/4X00/5X00 HF Resistant N0775357 1704<br />
Optima 3X00 DV/XL/3000 SCX Standard N8122188 606<br />
Optima 3X00 DV/XL/3000 SCX O-Ring Free N0775350 584<br />
Cyclonic Spray Chamber, Standard<br />
Part No. N0776052<br />
Baffled Cyclonic Spray Chambers<br />
The Baffled Cyclonic Spray Chamber features a central<br />
transfer tube which acts as a secondary particle separator,<br />
helping to separate larger aerosol particles from the sample.<br />
This reduces solvent load in the plasma without<br />
compromising detection limits.<br />
The internal baffle design has two important characteristics:<br />
1. The distance between the bottom of the baffle and the<br />
chamber wall is carefully controlled so that droplets<br />
cannot form on the bottom of the baffle. The advantage<br />
is smooth draining and improved precision.<br />
2. The baffle is cut at a sharp angle so that a large<br />
cross-section of the spray chamber is sampled as<br />
opposed to a straight cut which would have a very<br />
small sampling cross-section. The advantage is more<br />
representative sampling and reduced matrix effects.<br />
ICP Model Type Part No. Each (€)<br />
Optima 2X00/4X00/5X00 DV Standard N0776053 956<br />
Optima 2X00/4X00/5X00 DV O-Ring Free N0775352 704<br />
Optima 2X00/4X00/5X00 DV O-Ring Free N0775355 704<br />
for Organics<br />
(4 mm baffle)<br />
Optima 4300V/5300V Standard N0771501 800<br />
Optima 4300V/5300V O-Ring Free N0775356 704<br />
Optima 4300V/5300V HF Resistant N0771550 2071<br />
Baffled Cyclonic Spray Chamber,<br />
Standard Part No. N0776053<br />
Cyclonic Spray Chamber, O-Ring<br />
Free Part No. N0775351<br />
Baffled Cyclonic Spray Chamber,<br />
O-Ring Free Part No. N0775352<br />
Sample Introduction Inductively Coupled Plasma – OES<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
225
Sample Introduction<br />
Spray Chambers<br />
Inductively Coupled Plasma – OES Sample Introduction<br />
Ryton Scott Spray Chamber and Replacement Parts<br />
Ryton Scott Spray Chambers<br />
The Ryton Scott Spray Chamber is made from corrosionresistant<br />
Ryton, which is inert to most mineral acids including<br />
HF, Aqua Regia, and all organic solvents normally used in ICP<br />
analyses. The Scott-type design minimizes pulsations from<br />
the peristaltic pump. The Type II, two-piece design ensures<br />
leak-free performance. The removable inner tube allows the<br />
chamber to be easily disassembled for cleaning.<br />
ICP Model Part No. Each (€)<br />
Optima 2X00/4X00/5X00 N0770357 112<br />
Optima 3000/3000 SCR/3X00 RL N0690640 191<br />
Optima 3X00 DV/XL/3000 SCX N0690720 191<br />
Plasma 400 (Complete) N0580542 338<br />
Plasma 400 (Inner Tube) N0582259 198<br />
Plasma 400 (Outer Chamber) N0582258 60<br />
Ryton Scott External Spray Chamber Kit<br />
Ryton Scott External Spray Chamber Kit Replacement Parts for the Optima 3X00<br />
1<br />
2<br />
3<br />
4<br />
5<br />
6<br />
7<br />
8<br />
9<br />
10<br />
11<br />
12<br />
13<br />
14<br />
15<br />
16<br />
17<br />
18<br />
19<br />
20<br />
21<br />
1<br />
2<br />
4<br />
External Spray Chamber Kit for the Optima 3X00 series.<br />
Includes External Ryton Scott Type II Spray Chamber, 1.2 mm<br />
Quartz Injector, and appropriate<br />
mounting hardware. For use with<br />
high-volatility samples.<br />
Part No.<br />
N0690289<br />
Each (€)<br />
638<br />
Components Part No. Each (€)<br />
Polypropylene Male Compression Fitting 1/8 NPT, 1/4 in. Tubing 09903999 5<br />
Brass Male Compression Fitting, 1/8 NPT, 1/4 in. Tubing 09903428 6<br />
Aluminum Tubing Insert, 1/8 in. i.d. 1/4 in. o.d. 09903094 1<br />
Quartz Injector, 1.2 mm i.d. N0695460 166<br />
Torch Adapter (for External Spray Chamber Kit)* N0695426 159<br />
Silicone Tubing, 1/4 in. i.d., 1 m piece* B0018283 11<br />
TFE Teflon Tubing, 1/4 in., 1 m piece 02508059 13<br />
External Chamber Bracket N0695433 74<br />
Spray Chamber Adapter (for External Spray Chamber)* N0695368 214<br />
Nebulizer Argon Tube Assembly N0690677 29<br />
Silicone O-Ring (red) 0.364 in. i.d., 0.070 in. width* 09902247 2<br />
Viton O-Ring (for use with Silicone applications) 0.364 in. i.d., 0.070 in. width* 09902015 6<br />
Tygon ® Tube (F4040A), Translucent Yellow, 3/8 in. i.d., cut to 3/4 in.* 02506532 3<br />
Drain Adapter* N0695414 46<br />
Barbed Elbow Fitting, Kynar, 10-32 UNF Male, 3/32 in.* 09920262 3<br />
Solvent Flex Tubing, Yellow PVC, 0.060 in. i.d.* 09985729 2<br />
Barbed Coupler Fitting, Kynar, 3/32 in. Tubing to 3/32 in. Tubing 09920186 4<br />
Spray Chamber (inner) to be Assembled with Item 19* N0582258 60<br />
Spray Chamber (outer)* N0695222 225<br />
Machine Screw, 4-40 x 5/16 in. long, Binding Head SS<br />
Component Clip, 1.375 in. i.d. (to hold External Spray Chamber) 09986072 50<br />
*Can also be used as replacement parts for the Single-Slot Demountable Torch Assembly<br />
with External Spray Chamber (N0770608), for the Optima 2X00/4X00/5X00.<br />
3<br />
5<br />
6 7 10 8<br />
14<br />
15<br />
13<br />
16<br />
17<br />
18 / 19<br />
20<br />
9<br />
11<br />
12<br />
21<br />
226
Sample Introduction<br />
Torches and Torch Accessories<br />
Torches<br />
Torch Modules and Assemblies<br />
Demountable Quartz Torch<br />
for Optima 2X00/4X00/5X00 DV,<br />
Single-Slot Part No. N0770338<br />
Demountable<br />
Quartz Torches<br />
Demountable design using<br />
one-piece quartz tubing for<br />
plasma and auxiliary gas<br />
flow. Available in a wide<br />
range of styles from 0-3 Slots,<br />
depending on your instrument<br />
and application needs. Torches<br />
without slots are recommended<br />
for organic solvents. 1-Slot<br />
torches are the standard torch<br />
for aqueous solutions. 3-Slot<br />
torches are typically used for<br />
organics analysis.<br />
ICP Model # of Slots Part No. Each (€)<br />
Optima 2X00/4X00/5X00 DV 0 N0770343 306<br />
Optima 2X00/4X00/5X00 DV 0 (short ver.) N0770344 306<br />
Optima 2X00/4X00/5X00 DV 1 N0770338 306<br />
Optima 3X00 DV 2 N0691662 427<br />
Optima 3000 SCX/3X00 XL 0 N0695379 427<br />
Optima 3000/3000 SCR/3X00 RL 1 N0690568 427<br />
Optima 3000/3000 SCR/3X00 RL 3 N0681690 599<br />
and Plasma 400 Wear Metals<br />
Analyzer (for Organics)<br />
Optima 4300V/5300V 3 N0771500 427<br />
Plasma 400* 3 N0580528 453<br />
*Not to be used with the Plasma 400 Wear Metals Analyzer.<br />
Torch Bonnets<br />
Torch Bonnets<br />
The torch bonnet is used as a spacer between<br />
the Torch and RF Load Coil.<br />
ICP Model Part No. Each (€)<br />
Optima 2X00/4X00/5X00 N0775289 98<br />
Optima 3000/3000 SCR/3X00 RL N0695295 102<br />
(for instruments manufactured BEFORE 9/21/94)<br />
Optima 3000/3000 SCR/3X00 RL N0695456 236<br />
(for instruments manufactured AFTER 9/21/94)<br />
Optima 3X00 XL/3X00 DV N0691664 134<br />
Quick-Change Torch Module in Quick-Change<br />
Torch Module Support Stand<br />
Quick-Change Torch Module with Cyclonic Spray<br />
Chamber and Concentric Nebulizer<br />
Complete Torch and Sample<br />
Introduction Module including<br />
complete Single-Slot Demountable<br />
Torch, Mounting Block, 2 mm<br />
Alumina Injector, Cyclonic Spray<br />
Chamber, and MEINHARD Type C<br />
Concentric Nebulizer.<br />
ICP Model Part No. Each (€)<br />
Optima 2X00/4X00/5X00 N0770607 4005<br />
Quick-Change Torch Module with Ryton Scott<br />
Spray Chamber and GemTip Crossflow Nebulizer<br />
Complete Torch and Sample<br />
Introduction Module including<br />
Demountable Single-Slot Torch,<br />
Mounting Block, 2 mm Alumina<br />
Injector, Ryton Scott Spray Chamber,<br />
and GemTip Crossflow II Nebulizer.<br />
Useful when a separate sample<br />
introduction is required for<br />
running different sample types.<br />
For Optima 2X00/4X00/5X00<br />
Part No. N0770606<br />
ICP Model Part No. Each (€)<br />
Optima 2X00/4X00/5X00 DV N0770606 3469<br />
Optima 3000/3000 SCR/3X00 RL N0690610 2678<br />
Optima 3X00 DV N0690812 3214<br />
Optima 3X00 XL/3000 SCX N0690712 3214<br />
Quick-Change Torch Module Support Stand<br />
A free-standing support stand to hold your spare Quick-<br />
Change Torch Module or as a means of conveniently holding<br />
your module when working inside the sample compartment.<br />
ICP Model Part No. Each (€)<br />
Optima 2X00/4X00/5X00 DV N0770609 128<br />
Optima 3X00 N0690636 204<br />
Mounting Block for Quick Change Torch Modules<br />
Mounting block only. Does not include torch, injector, spray<br />
chamber, or nebulizer. For Optima 2X00/4X00/5X00.<br />
Part No.<br />
Each (€)<br />
N0770600 2270<br />
Sample Introduction Inductively Coupled Plasma – OES<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
227
Inductively Coupled Plasma – OES Sample Introduction<br />
Sample Introduction<br />
Torches and Torch Accessories<br />
Quick-Change Torch Module for Dry Aerosols<br />
A Quick-Change Torch Module designed for the introduction<br />
of dry sample aerosols, such as ultrasonic nebulization, laser<br />
sampling, spark ablation, and electrothermal vaporization.<br />
For use with the Optima 3000, 3000 SCR, and 3X00 RL.<br />
Includes Single-Slot Demountable Torch, 2 mm Alumina<br />
Injector, Dry Aerosol Injector Support<br />
Adapter, Mounting Block, Gas Lines, Part No. Each (€)<br />
and Fittings.<br />
N0690638 1990<br />
Dry Aerosol Block and Injector Assembly<br />
Allows the standard Quick-Change Torch Module to be used<br />
as a dry aerosol system. For use with the Optima 3000, 3000<br />
SCR, and 3X00 RL. Includes Dry Aerosol<br />
Injector Support Adapter, Mounting<br />
Block, and Fittings.<br />
Part No.<br />
N0690637<br />
Each (€)<br />
414<br />
Dry Aerosol Adapter for Ultrasonic Nebulization<br />
Adapter to connect 1/4 in. tubing to Injector Support Adapter<br />
(N0695400 or N0770603). For use with ultrasonic nebulization<br />
with the Optima 2X00 DV, 3X00 XL, 3X00 DV, 3000 SCX,<br />
4X00 DV, and 5X00 DV.<br />
Part No. Each (€)<br />
Quick-Change Torch Module<br />
for HF-Resistant Analysis<br />
Complete Torch and Sample Introduction Assembly for the<br />
Optima 4300V and 5300V, including the 3-Slot Demountable<br />
Quartz Torch, Mounting Block, 2 mm Alumina Injector,<br />
HF Resistant Cyclonic Spray Chamber, and GemCone<br />
High Dissolved Solids Nebulizer.<br />
Part No. Each (€)<br />
Quick-Change Torch Module for Used Oil Analysis<br />
Complete Torch and Sample Introduction Assembly<br />
for the Optima 4300V and 5300V, including the 3-Slot<br />
Demountable Quartz Torch, Mounting Block, 1.2 mm<br />
Alumina Injector, Baffled Cyclonic<br />
Spray Chamber, and GemCone<br />
Low-Flow Nebulizer.<br />
Part No.<br />
N0770910<br />
Each (€)<br />
2100<br />
Single-Slot Demountable Torch Assembly<br />
with External Spray Chamber<br />
N0690770 145<br />
N0770911 3799<br />
Complete Torch and External Spray Chamber Assembly<br />
for the Optima 2X00/4X00/5X00, including Single-Slot<br />
Demountable Torch, 2 mm Quartz Injector, 1.6 mm Quartz<br />
Injector, External Ryton ® Scott Type II Spray Chamber,<br />
O-Rings, and appropriate mounting<br />
hardware. For use with<br />
high-volatility samples.<br />
Part No.<br />
N0770608<br />
Each (€)<br />
1943<br />
Demountable Type II Torch Assembly<br />
with Ryton ® Type II Spray Chamber<br />
Complete Torch and Spray Chamber Assembly for the Plasma<br />
400, including Type II Demountable Torch, Mounting Block,<br />
2 mm Alumina Injector, Ryton Type II<br />
Spray Chamber, O-Ring Kit, and<br />
appropriate mounting hardware.<br />
Part No.<br />
N0680241<br />
Each (€)<br />
1250<br />
Torch Replacement Parts<br />
Torch O-Rings<br />
ICP Model Location Dimensions Part No. Each (€)<br />
Optima 2X00/3X00/ Torch 0.612 i.d., 09902155 3<br />
4X00/5X00 DV Base Mount 0.103 w.d.<br />
Optima 3X00 XL/ 0.239 i.d., 09902006 2<br />
3X00 DV/3000 SCX<br />
0.070 w.d.<br />
Optima 3X00 XL/ 0.364 i.d., 09902015 6<br />
3X00 DV/3000 SCX<br />
0.070 w.d.<br />
Optima 3X00 XL/ 8.74 i.d., 09921028 1<br />
3X00 DV/3000 SCX<br />
1.78 w.d.<br />
Optima 3X00 XL/ Torch 0.239 i.d., 09902207 4<br />
3X00 DV/3000 SCX/ Adapter - 0.070 w.d.<br />
4300V/5300V Inside<br />
Optima 3X00 XL/ Torch 0.301 i.d., 09902247 2<br />
3X00 DV/3000 SCX/ Adapter - 0.070 w.d.<br />
4300V/5300V Outside<br />
Optima 4300V/5300V Ball Joint 0.301 i.d., 09926070 1<br />
0.070 w.d.<br />
Plasma 400 09902152 2<br />
Plasma 400 09902225 1<br />
Torch O-Ring Kits<br />
Kits contain a selection of O-Rings for ICP Demountable<br />
Torches. Replacement of the torch O-Rings is normally<br />
recommended when replacing a quartz torch.<br />
ICP Model Part No. Each (€)<br />
Optima 2X00/4X00/5X00 N0770437 27<br />
Optima 3000/3000 SCR/3X00 RL N0690269 25<br />
Optima 3X00 XL/3X00 DV/3000 SCX N0690769 25<br />
Plasma 400/400 WMA N0580539 59<br />
(includes O-Rings for the Injector Support Adapter)<br />
Plasma Gas/Ignitor Cable “T” Connection<br />
for Optima 3000/3000 XL<br />
Quartz Torch Copper Ignitor Tape<br />
Used for all torches with the<br />
Optima 2X00/4X00/5X00.<br />
Sheet with 48 squares.<br />
Part No.<br />
Part No.<br />
Each (€)<br />
N0690607 62<br />
Each (€)<br />
N0775297 13<br />
228
Sample Introduction<br />
Torches and Torch Accessories<br />
Torch Replacement Parts<br />
Quick-Change Torch Module Replacement Parts<br />
for Optima 3000, 3X00 RL, and 3X00 SCR<br />
1<br />
2<br />
3<br />
4<br />
5<br />
6<br />
7<br />
8<br />
9<br />
10<br />
11<br />
12<br />
13<br />
14<br />
15<br />
16<br />
17<br />
18<br />
19<br />
20<br />
21<br />
22<br />
23<br />
24<br />
25<br />
26<br />
27<br />
28<br />
Components Part No. Each (€)<br />
Thumbscrew #10 N0580534 8<br />
GemTip TM Crossflow II Nebulizer and N0680503 504<br />
End Cap Assembly<br />
Alumina Injector, 2.0 mm i.d. N0582184 159<br />
Ryton Scott Spray Chamber – N0582258 60<br />
Inner Tube (combine with item 12)<br />
Quartz Torch Demountable, Single Slot N0690568 427<br />
Assembly – Adjustable Mount N0690593 1160<br />
Cable Assembly – RF Ignitor N0690607 62<br />
Fitting – N0695214 126<br />
Couple Injector to Spray Chamber<br />
Support – Torch N0695220 268<br />
Ryton Scott Spray Chamber – N0695222 225<br />
Outer Tube (combine with item 4)<br />
Pointer – Adjustable Mount N0695225 22<br />
Clamp Plate N0695238 73<br />
Screw, Knurled N0581558 51<br />
Clamp Bracket N0581793 24<br />
O-Ring 00473194 4<br />
Clear Tygon Tubing (per foot) 02506516 1<br />
O-Ring 09902207 4<br />
O-Ring 09902155 3<br />
O-Ring 09902247 2<br />
Insert 09903094 1<br />
O-Ring 09902015 6<br />
Screw – BDHM 6-32 x 1/4 in.<br />
Polyethylene Tube (per foot) 02506517 1<br />
Connector 1/8 NPT to 1/4 TBG<br />
Insert 1/4 in. o.d. 3/16 in. i.d. 09920118 7<br />
Marker – Plasma 09940438 28<br />
Marker – Aux<br />
Barb Fitting Male – 10-32 NPT 1/8 TBG 09920034 2<br />
Demountable Torch Replacement Parts<br />
for Optima 3X00<br />
A<br />
B<br />
C1<br />
C2<br />
1<br />
2<br />
3<br />
Components Part No. Each (€)<br />
Alumina Injector, 2.0 mm i.d.:<br />
Optima 3000/3000 SCR/3X00 RL N0582184 159<br />
Optima 3000 DV/3000 SCX/3X00 XL N0695362 166<br />
Demountable Quartz Torch:<br />
Single Slot for Optima 3000/ N0690568 427<br />
3000 SCR/3X00 RL<br />
No Slot Torch N0695379 427<br />
for Optima 3X00 SCX/3X00 XL<br />
2-Slot Torch for Optima 3X00 DV N0691662 427<br />
Injector Support Adapter:<br />
Optima 3000/3000 SCR/3X00 RL N0695214 126<br />
with Ryton ® Scott Spray Chambers<br />
Optima 3000 SCX/3X00 DV/3X00 XL N0695400 242<br />
with Ryton Scott Spray Chambers<br />
Optima 3000 SCX/3X00 DV/3X00 XL N0690780 242<br />
with Cyclonic Spray Chambers<br />
O-Ring 09902155 3<br />
O-Ring 09902247 2<br />
O-Ring 09902006 2<br />
See page 220 for our full selection of Alumina, Quartz, and Saphire Injectors.<br />
5<br />
18<br />
12<br />
1<br />
9<br />
11 / 22<br />
10<br />
4<br />
C2<br />
7<br />
B<br />
1<br />
A<br />
2<br />
15<br />
23 / 25 / 27<br />
6<br />
20 / 24 / 28<br />
16 / 26<br />
3<br />
17<br />
2<br />
19<br />
8<br />
14<br />
21<br />
13<br />
3<br />
C1<br />
2<br />
Sample Introduction Inductively Coupled Plasma – OES<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
229
Sample Introduction<br />
Torches and Torch Accessories<br />
Torch Replacement Parts<br />
Quick-Change Torch Module Replacement Parts<br />
for Optima 3X00 DV, 3X00 SCX, 3X00 XL<br />
Components Part No. Each (€)<br />
Inductively Coupled Plasma – OES Sample Introduction<br />
1<br />
2<br />
3<br />
4<br />
5<br />
6<br />
7<br />
8<br />
9<br />
10<br />
11<br />
12<br />
13<br />
14<br />
15<br />
16<br />
17<br />
18<br />
19<br />
20<br />
21<br />
22<br />
23<br />
24<br />
25<br />
26<br />
27<br />
28<br />
29<br />
30<br />
31<br />
Alumina Injector, 2.0 mm i.d. N0695362 166<br />
Block – Axial – Dove Tail N0695367 164<br />
Fitting – Axial N0695400 242<br />
Cable Assembly – RF Generator Ignitor N0690607 62<br />
Tygon Tubing (per foot) 02506516 1<br />
Polyethylene Tubing (per foot) 02506517 1<br />
O-Ring 00473194 4<br />
Cap – Screw 10-32, 0.625 Long, SS<br />
Barb Fitting Male – 09920034 2<br />
10-32 NPT 1/8 TBG<br />
O-Ring 09902207 4<br />
O-Ring 09902155 3<br />
O-Ring 09902247 2<br />
Tubing Insert, 0.125 i.d. 09903094 1<br />
Knob – Thumbscrew SCR 10 09908522 2<br />
6-32 x 3/8 SOC Cap Screw<br />
8-32 x 3/8 SOC Cap Screw<br />
SOC Cap 10-32 x 1/2 SS<br />
Washer, Flat #8<br />
Lock Washer, #8<br />
Quick Connect Stem 1/8 Tubing, Barb 09920021 57<br />
Clamp Hose – 1/4 in. Bypass 09903021 1<br />
Insert – Tube 1/4 o.d. x 3/16 i.d. 09920118 7<br />
O-Ring 09921028 1<br />
Knob – Thumbscrew 09923012 2<br />
Wire Marker Strip 09940438 28<br />
Bev-A-Line Tubing, 09985727 2<br />
0.125 i.d., Clear (per foot)<br />
Wire Marker – AUX<br />
Tubing Silicone (per foot) 09985514 3<br />
Axial Drain Fitting 09920528 3<br />
PVC Tubing, 1.5 mm i.d. 09985729 2<br />
Clamp Plate N0695381 51<br />
15 / 24 3 10 1<br />
23 12<br />
29<br />
30<br />
8<br />
16 / 18 / 19<br />
2 31 14 / 17<br />
11<br />
28<br />
15<br />
9<br />
“Plasma”<br />
4<br />
7 5 / 13 / 25<br />
26<br />
“Neb”<br />
“Aux”<br />
20 21 28 6 / 22 / 27<br />
230
Standards<br />
PerkinElmer Pure Standards for ICP-OES<br />
Depend on Genuine<br />
PerkinElmer Pure Standards<br />
Whatever Your Application,<br />
You Can Count on PerkinElmer<br />
Pure Standards to Yield Reliable,<br />
Accurate Results<br />
PerkinElmer offers a wide selection of standards for ICP-OES.<br />
Each solution is supplied with a comprehensive Certificate<br />
of Analysis that documents the quality. To ensure that your<br />
measurements are accurate, you can rely on our certificates<br />
to provide complete information.<br />
PerkinElmer Pure Atomic Spectroscopy Standards are manufactured<br />
for PerkinElmer to the highest quality standards.<br />
Quality<br />
PerkinElmer Pure standards are prepared<br />
gravimetrically from high-purity metals<br />
and salts, using high-purity reagents.<br />
■ ASTM Type I, filtered water minimizes cations,<br />
anions, and colloids; resistivity is maintained in<br />
the 18-megohm range.<br />
■ Acids used are the highest purity.<br />
■ Semi-micro analytical balances and Class A volumetric<br />
glassware are used, and the bottles are subjected to a<br />
stringent leaching/cleaning process.<br />
■ Following preparation, standards are analyzed<br />
for the major element as well as trace impurities.<br />
The results of the analysis are provided on the<br />
Certificate of Analysis.<br />
Reliability<br />
Multi-element standards are measured<br />
by three methods:<br />
1. Complete analysis (wet and ICP)<br />
of the starting materials<br />
2. Wet and ICP analysis of the<br />
individual prepared standards<br />
3. ICP-MS check of the final multi-element standard<br />
The results of these three analyses are<br />
reported on the Certificate of Analysis.<br />
NIST or NBS SRMs used for the ICP<br />
check are also reported on the<br />
Certificate of Analysis.<br />
Safety<br />
We ship standards to comply with both<br />
DOT and IATA regulations to ensure<br />
their safe delivery to you.<br />
Features<br />
■ ISO 9001 accredited by Underwriters Laboratories<br />
including comprehensive continuous improvement,<br />
product recall, corrective action request, and other<br />
quality maintenance and improvement programs<br />
■ Accreditation by NVLAP/NIST as an EPA performance<br />
testing provider<br />
■ Product labeling meets OSHA and California<br />
labeling standards<br />
■ Bottles are low-density polyethylene from industry<br />
standard Nalge Corporation and are pre-leached and<br />
pre-treated for increased product stability and purity<br />
■ High-purity acids and ASTM Type I water used in<br />
all manufacturing, as reported on the Certificate<br />
of Analysis<br />
■ Traceability directly to NIST standard reference<br />
materials, not independent sources or secondary<br />
NIST SRMs and reported on the Certificate<br />
of Analysis<br />
■ Wet assays on all multi-element products via<br />
standard, accepted wet methods and traceable<br />
directly to NIST SRM to +/-0.5% of true value<br />
and reported on the Certificate of Analysis<br />
■ All solutions tested and confirmed for the absence<br />
of interfering anions, e.g. chloride, bromide, etc.<br />
■ Twelve months guaranteed stability +/-0.5% for<br />
all major analytes for all products<br />
www.perkinelmer.com/<strong>supplies</strong> 231
Standards<br />
PerkinElmer Pure Standards for ICP-OES<br />
Inductively Coupled Plasma – OES Standards<br />
Alternate Trace Metal Drinking Water<br />
and Wastewater Pollution Standards<br />
Alternate Metals I<br />
Matrix/Vol. Concentration of Element Part No. Each (€)<br />
2% HNO 3 /100 mL 20 μg/mL Aluminum N9300214 190<br />
5 μg/mL Antimony<br />
5 μg/mL Beryllium<br />
10 μg/mL Cobalt<br />
10 μg/mL Copper<br />
20 μg/mL Iron<br />
10 μg/mL Manganese<br />
10 μg/mL Nickel<br />
5 μg/mL Thallium<br />
20 μg/mL Vanadium<br />
10 μg/mL Zinc<br />
Alternate Metals II<br />
Matrix/Vol. Concentration of Element Part No. Each (€)<br />
2% HNO 3 /100 mL 500 μg/mL Calcium N9300215 114<br />
100 μg/mL Magnesium<br />
100 μg/mL Potassium<br />
500 μg/mL Sodium<br />
Contract Required Detection<br />
Limits (CRDL) Standard<br />
Used to verify the Contract Required Detection Limits (CRDL)<br />
for ICP and HGA ® elements<br />
Contains all the required elements on the TAL at the correct<br />
concentration ratios<br />
Dilute by a factor of 1,000 prior to use to meet the “two times<br />
CRDL” requirement for ICP analysis and by a factor of 2,000<br />
to meet the “one times CRDL” requirement for HGA analysis<br />
Use at the start and end of each sample analysis or at least<br />
twice in an eight-hour shift for ICP, and at the start of your<br />
sample analysis run for HGA<br />
CRDL Standard<br />
Matrix/Vol. Concentration of Element Part No. Each (€)<br />
5% HNO 3 /100 mL 120 μg/mL Antimony N9300225 228<br />
20 μg/mL Arsenic<br />
10 μg/mL Beryllium<br />
10 μg/mL Cadmium<br />
20 μg/mL Chromium<br />
100 μg/mL Cobalt<br />
50 μg/mL Copper<br />
6 μg/mL Lead<br />
30 μg/mL Manganese<br />
80 μg/mL Nickel<br />
10 μg/mL Selenium<br />
20 μg/mL Silver<br />
20 μg/mL Thallium<br />
100 μg/mL Vanadium<br />
40 μg/mL Zinc<br />
Drinking Water Pollutant Standards<br />
Recommended for use in procedures for compliance<br />
monitoring of drinking water<br />
Recommended for the analysis of ground and surface<br />
water where determination at the drinking water<br />
contaminant levels is required<br />
Supplied in two bottles. Mercury (100 mL at 10 μg/mL)<br />
is included, but shipped in a separate bottle<br />
For use with U.S. EPA SW-846, method 1310 and U.S. National Primary<br />
Drinking Water Regulations 40 CFR Part 141. Secondary metals from<br />
U.S. EPA Appendix to 200.7 used in the analysis of drinking water by ICP.<br />
Primary Drinking Water Metals<br />
Matrix/Vol. Concentration of Element Part No. Each (€)<br />
2% HNO 3 /100 mL 10 μg/mL Arsenic N9300216 152<br />
100 μg/mL Barium<br />
5 μg/mL Cadmium<br />
10 μg/mL Chromium<br />
10 μg/mL Lead<br />
5 μg/mL Selenium<br />
10 μg/mL Silver<br />
10 μg/mL Mercury<br />
Secondary Drinking Water Metals<br />
Matrix/Vol. Concentration of Element Part No. Each (€)<br />
2% HNO 3 /100 mL 100 μg/mL Copper N9300217 114<br />
30 μg/mL Iron<br />
5 μg/mL Manganese<br />
500 μg/mL Zinc<br />
232
Standards<br />
PerkinElmer Pure Standards for ICP-OES<br />
Groundwater and Wastewater<br />
Pollution Control Check Standards<br />
Use as a daily control standard<br />
Check the accuracy and precision of your analysis<br />
Refer to U.S. EPA methods manual 600/4-79-020, “Methods for Chemical<br />
Analysis of Water and Wastes”: Trace metals I, II, and III methods.<br />
Trace Metals I<br />
Matrix/Vol. Concentration of Element Part No. Each (€)<br />
5% HNO 3 /100 mL 500 μg/mL Aluminum N9300211 228<br />
100 μg/mL Arsenic<br />
100 μg/mL Beryllium<br />
25 μg/mL Cadmium<br />
100 μg/mL Chromium<br />
100 μg/mL Cobalt<br />
100 μg/mL Copper<br />
100 μg/mL Iron<br />
100 μg/mL Lead<br />
100 μg/mL Manganese<br />
5 μg/mL Mercury<br />
100 μg/mL Nickel<br />
25 μg/mL Selenium<br />
250 μg/mL Vanadium<br />
100 μg/mL Zinc<br />
Trace Metals II<br />
Matrix/Vol. Concentration of Element Part No. Each (€)<br />
2% HNO 3 /100 mL 20 μg/mL Antimony N9300212 88<br />
10 μg/mL Silver<br />
20 μg/mL Thallium<br />
Trace Metals III<br />
Matrix/Vol. Concentration of Element Part No. Each (€)<br />
2% HNO 3 /100 mL 500 μg/mL Barium N9300213 152<br />
500 μg/mL Calcium<br />
100 μg/mL Magnesium<br />
500 μg/mL Molybdenum<br />
100 μg/mL Potassium<br />
500 μg/mL Sodium<br />
Instrument Calibration Standards<br />
Please see page 66 for our full selection of Instrument Calibration Standards<br />
for Contract Laboratory Program (CLP) analysis.<br />
Low UV Standard<br />
Matrix/Vol. Concentration of Element Part No. Each (€)<br />
2% HNO 3 /250 mL 10 μg/mL Aluminum N0691580 126<br />
10 μg/mL Phosphorus<br />
10 μg/mL Sulfur<br />
Calcium Stray Light Standard<br />
Matrix/Vol. Concentration of Element Part No. Each (€)<br />
H 2 O /100 mL 10,000 μg/mL Calcium N0691581 88<br />
Interference Check Standards<br />
Used to verify interelement and background correction<br />
factors required at the beginning and the end of each<br />
analysis run or at least twice in an eight-hour shift.<br />
Interference checks require two solutions: the interferents<br />
alone, and the combination of interferents and analytes.<br />
Interferents A Solution<br />
To prepare the solution of interferents alone, dilute<br />
N9300226 by a factor of 10. To prepare the solution of<br />
interferents and analytes, dilute 10 mL of interferents<br />
solution (N9300226) and 1 mL of analytes solution<br />
(N9300227) to 100 mL with 5% high-purity HNO 3 .<br />
Matrix/Vol. Concentration of Element Part No. Each (€)<br />
5% HNO 3 /500 mL 5,000 μg/mL Aluminum N9300226 356<br />
5,000 μg/mL Calcium<br />
2,000 μg/mL Iron<br />
5,000 μg/mL Magnesium<br />
Analytes B Solution<br />
Matrix/Vol. Concentration of Element Part No. Each (€)<br />
5% HNO 3 /100 mL 60 μg/mL Antimony N9300227 190<br />
10 μg/mL Arsenic<br />
50 μg/mL Barium<br />
50 μg/mL Beryllium<br />
100 μg/mL Cadmium<br />
50 μg/mL Chromium<br />
50 μg/mL Cobalt<br />
50 μg/mL Copper<br />
5 μg/mL Lead<br />
50 μg/mL Manganese<br />
100 μg/mL Nickel<br />
5 μg/mL Selenium<br />
20 μg/mL Silver<br />
10 μg/mL Thallium<br />
50 μg/mL Vanadium<br />
100 μg/mL Zinc<br />
Alternate Interferents A Solution<br />
Besides the four interferents in N9300226, six more elements<br />
that can interfere with the determination of the elements on<br />
the TAL are listed in EPA SOW.3/90 and ILM04.0. Alternate<br />
Interferents A solution contains these elements. Together<br />
these solutions enable you to check and correct for all the<br />
interferences listed in SOW.3/90.<br />
Two solutions are required. To prepare the interferents<br />
solution, combine 10 mL of N9300226 with 10 mL of<br />
N9300228 and dilute to 100 mL with 5% high-purity HNO 3 .<br />
To prepare the solution of interferents and analytes,<br />
combine 10 mL of N9300226 with 10 mL of N9300228,<br />
1 mL of N9300227 and 1 mL of N9300229 and dilute to<br />
100 mL with 5% high-purity HNO 3 .<br />
Matrix/Vol. Concentration of Element Part No. Each (€)<br />
5% HNO 3 /500 mL 1,000 μg/mL Chromium N9300228 292<br />
1,000 μg/mL Copper<br />
1,000 μg/mL Manganese<br />
1,000 μg/mL Nickel<br />
1,000 μg/mL Thallium<br />
1,000 μg/mL Vanadium<br />
Standards Inductively Coupled Plasma – OES<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
233
Standards<br />
PerkinElmer Pure Standards for ICP-OES<br />
Inductively Coupled Plasma – OES Standards<br />
Alternate Analytes B Solution<br />
Matrix/Vol. Concentration of Element Part No. Each (€)<br />
5% HNO 3 /100 mL 100 μg/mL Aluminum N9300229 228<br />
100 μg/mL Arsenic<br />
100 μg/mL Boron<br />
10 μg/mL Calcium<br />
10 μg/mL Iron<br />
10 μg/mL Magnesium<br />
100 μg/mL Molybdenum<br />
100 μg/mL Sodium<br />
100 μg/mL Antimony<br />
100 μg/mL Selenium<br />
10 μg/mL Silicon<br />
100 μg/mL Thallium<br />
Interference Check Standard, 18<br />
Use to set or confirm that the correct background correction<br />
intervals have been set. For use in U.S. EPA SW-846,<br />
method 6010 section 5.7 and method 200.7 section 7.6.2.<br />
Matrix/Vol. Concentration of Element Part No. Each (€)<br />
5% HNO 3 /100 mL 1,000 μg/mL Arsenic N9300205 381<br />
300 μg/mL Barium<br />
100 μg/mL Beryllium<br />
300 μg/mL Cadmium<br />
300 μg/mL Chromium<br />
300 μg/mL Cobalt<br />
300 μg/mL Copper<br />
1,000 μg/mL Lead<br />
200 μg/mL Manganese<br />
50 μg/mL Mercury<br />
300 μg/mL Nickel<br />
20,000 μg/mL Potassium<br />
500 μg/mL Selenium<br />
300 μg/mL Silver<br />
1,000 μg/mL Thallium<br />
300 μg/mL Vanadium<br />
300 μg/mL Zinc<br />
Interference Check Standard, Sb<br />
Matrix/Vol. Concentration of Element Part No. Each (€)<br />
2% HNO 3 /500 mL 1,000 μg/mL Antimony N9300101 101<br />
Interference Check Standard, 5 Elements<br />
Matrix/Vol. Concentration of Element Part No. Each (€)<br />
5% HNO 3 /100 mL 1,200 μg/mL Aluminum N9300208 228<br />
6,000 μg/mL Calcium<br />
5,000 μg/mL Iron<br />
3,000 μg/mL Magnesium<br />
1,000 μg/mL Sodium<br />
Spike Samples<br />
Used to check the effect of sample matrix and<br />
methodology on spike recovery<br />
Add 1.0 mL of spike sample to your aqueous samples<br />
and add 2.0 mL of spike sample to your solid samples<br />
prior to digestion<br />
Matrix/Vol. Concentration of Element Part No. Each (€)<br />
5% HNO 3 /100 mL 200 μg/mL Aluminum N9300230 292<br />
50 μg/mL Antimony<br />
200 μg/mL Arsenic<br />
200 μg/mL Barium<br />
5 μg/mL Beryllium<br />
5 μg/mL Cadmium<br />
20 μg/mL Chromium<br />
50 μg/mL Cobalt<br />
25 μg/mL Copper<br />
100 μg/mL Iron<br />
50 μg/mL Lead<br />
50 μg/mL Manganese<br />
50 μg/mL Nickel<br />
200 μg/mL Selenium<br />
5 μg/mL Silver<br />
200 μg/mL Thallium<br />
50 μg/mL Vanadium<br />
50 μg/mL Zinc<br />
Multi-Element Standards<br />
Multi-element standards were formulated for use with U.S.<br />
EPA methods but can be used with many other methods<br />
successfully. For use in U.S. EPA SW-846, method 6010<br />
section 5.4, as well as method 200.7 section 7.4.<br />
Mixed Standard Solution I<br />
Matrix/Vol. Concentration of Element Part No. Each (€)<br />
2% HNO 3 /100 mL 50 μg/mL Beryllium N9300200 152<br />
150 μg/mL Cadmium<br />
500 μg/mL Lead<br />
100 μg/mL Manganese<br />
200 μg/mL Selenium<br />
150 μg/mL Zinc<br />
Mixed Standard Solution II<br />
Matrix/Vol. Concentration of Element Part No. Each (€)<br />
5% HNO 3 /100 mL 100 μg/mL Barium N9300201 126<br />
100 μg/mL Cobalt<br />
100 μg/mL Copper<br />
10,000 μg/mL Iron<br />
100 μg/mL Vanadium<br />
Mixed Standard Solution III<br />
Matrix/Vol. Concentration of Element Part No. Each (€)<br />
2% HNO 3 /100 mL 500 μg/mL Arsenic N9300202 101<br />
100 μg/mL Molybdenum<br />
100 μg/mL Silicon<br />
234
Standards<br />
PerkinElmer Pure Standards for ICP-OES<br />
Mixed Standard Solution IV<br />
Matrix/Vol. Concentration of Element Part No. Each (€)<br />
5% HNO 3 /100 mL 200 μg/mL Aluminum N9300203 152<br />
1,000 μg/mL Calcium<br />
20 μg/mL Chromium<br />
20 μg/mL Nickel<br />
400 μg/mL Potassium<br />
200 μg/mL Sodium<br />
Mixed Standard Solution V<br />
Matrix/Vol. Concentration of Element Part No. Each (€)<br />
5% HNO 3 /100 mL 200 μg/mL Antimony N9300204 126<br />
100 μg/mL Boron<br />
1,000 μg/mL Magnesium<br />
50 μg/mL Silver<br />
200 μg/mL Thallium<br />
Multi-Element Standard<br />
Matrix/Vol. Concentration of Element Part No. Each (€)<br />
2% HNO 3 /500 mL 50 μg/mL Arsenic N0691579 318<br />
1 μg/mL Barium<br />
10 μg/mL Lanthanum<br />
1 μg/mL Magnesium<br />
10 μg/mL Manganese<br />
10 μg/mL Nickel<br />
50 μg/mL Potassium<br />
10 μg/mL Strontium<br />
10 μg/mL Zinc<br />
Quality Control Standards<br />
Use for trace metal analysis<br />
Check your standard curve<br />
Economical, 100 mL volume<br />
For U.S. EPA method 200.7 and EPA methods manual 600/482-055<br />
“Technical Additions to Methods for Chemical Analysis of Water and Wastes.”<br />
Quality Control Standard, 21 Elements<br />
Matrix/Vol. Concentration of Element Part No. Each (€)<br />
5% HNO 3 /100 mL 100 μg/mL Antimony N9300281 318<br />
100 μg/mL Arsenic<br />
100 μg/mL Beryllium<br />
100 μg/mL Cadmium<br />
100 μg/mL Calcium<br />
100 μg/mL Chromium<br />
100 μg/mL Cobalt<br />
100 μg/mL Copper<br />
100 μg/mL Iron<br />
100 μg/mL Lead<br />
100 μg/mL Lithium<br />
100 μg/mL Magnesium<br />
100 μg/mL Manganese<br />
100 μg/mL Molybdenum<br />
100 μg/mL Nickel<br />
100 μg/mL Selenium<br />
100 μg/mL Strontium<br />
100 μg/mL Thallium<br />
100 μg/mL Titanium<br />
100 μg/mL Vanadium<br />
100 μg/mL Zinc<br />
Quality Control Standard, 7A Elements<br />
Matrix/Vol. Concentration of Element Part No. Each (€)<br />
5% HNO 3 /100 mL 100 μg/mL Aluminum N9300280 152<br />
100 μg/mL Barium<br />
100 μg/mL Boron<br />
1,000 μg/mL Potassium<br />
500 μg/mL Silicon<br />
50 μg/mL Silver<br />
100 μg/mL Sodium<br />
TCLP<br />
Recommended for use in the Toxicity Characteristics<br />
Leachate Procedure, Method 1311.<br />
Matrix/Vol. Concentration of Element Part No. Each (€)<br />
2% HNO 3 /500 mL 25 μg/mL Arsenic N9300241 318<br />
500 μg/mL Barium<br />
5 μg/mL Cadmium<br />
25 μg/mL Chromium<br />
25 μg/mL Lead<br />
5 μg/mL Selenium<br />
25 μg/mL Silver<br />
20 μg/mL Mercury*<br />
* Mercury is supplied in a separate 500 mL bottle.<br />
Standards Inductively Coupled Plasma – OES<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
235
Standards<br />
PerkinElmer Pure Standards for ICP-OES<br />
Inductively Coupled Plasma – OES Standards<br />
Wavecal Solutions<br />
VIS Wavecal Solution<br />
Matrix/Vol. Concentration of Element Part No. Each (€)<br />
2% HNO 3 /250 mL 1 μg/mL Barium N9302946 228<br />
1 μg/mL Calcium<br />
10 μg/mL Lanthanum<br />
10 μg/mL Lithium<br />
10 μg/mL Manganese<br />
50 μg/mL Potassium<br />
10 μg/mL Sodium<br />
10 μg/mL Strontium<br />
UV Wavecal Solution<br />
Correct for calibration changes automatically using the<br />
Wavecal program in your ICP spectrometer’s software.<br />
For use in U.S. EPA SW-846, Method 6010 section 5.6<br />
and method 200.7 section 7.6.1.<br />
Matrix/Vol. Concentration of Element Part No. Each (€)<br />
2% HCI/100 mL 20 μg/mL Arsenic N0681470 24<br />
20 μg/mL Lanthanum<br />
20 μg/mL Lithium<br />
20 μg/mL Manganese<br />
20 μg/mL Molybdenum<br />
20 μg/mL Nickel<br />
100 μg/mL Phosphorus<br />
100 μg/mL Potassium<br />
20 μg/mL Scandium<br />
20 μg/mL Sodium<br />
100 μg/mL Sulfur<br />
2% HCI/500 mL 20 μg/mL Arsenic N0582152 45<br />
20 μg/mL Lanthanum<br />
20 μg/mL Lithium<br />
20 μg/mL Manganese<br />
20 μg/mL Molybdenum<br />
20 μg/mL Nickel<br />
100 μg/mL Phosphorus<br />
100 μg/mL Potassium<br />
20 μg/mL Scandium<br />
20 μg/mL Sodium<br />
100 μg/mL Sulfur<br />
Plasma 40 Wear Metals Wavecal Organic Solution<br />
Before using, dilute to a concentration of 20 μg/mL.<br />
Matrix/Vol. Concentration of Element Part No. Each (€)<br />
75/85 Base Oil/4 oz. 500 μg/mL Aluminum N0681581 547<br />
500 μg/mL Barium<br />
500 μg/mL Boron<br />
500 μg/mL Cadmium<br />
500 μg/mL Calcium<br />
500 μg/mL Chromium<br />
500 μg/mL Copper<br />
500 μg/mL Iron<br />
500 μg/mL Lead<br />
500 μg/mL Lithium<br />
500 μg/mL Magnesium<br />
500 μg/mL Manganese<br />
500 μg/mL Molybdenum<br />
500 μg/mL Nickel<br />
500 μg/mL Phosphorus<br />
500 μg/mL Potassium<br />
500 μg/mL Silicon<br />
500 μg/mL Silver<br />
500 μg/mL Sodium<br />
500 μg/mL Tin<br />
500 μg/mL Titanium<br />
500 μg/mL Vanadium<br />
500 μg/mL Zinc<br />
236
Infrared Spectroscopy<br />
PerkinElmer is the preferred choice for<br />
reliable Infrared (IR) solutions in thousands<br />
of laboratories worldwide. The speed, accuracy<br />
and quality of results deliver proven, long-term cost<br />
savings. With 60+ years of IR experience, PerkinElmer understands each<br />
laboratory’s unique requirements – delivering solutions tailored to your<br />
specific analytical needs.<br />
We offer the industry’s broadest range of IR products.<br />
PerkinElmer instruments are built to the highest ISO-9000<br />
standards, delivering fast, accurate results consistently.<br />
Our continual innovation assures you’re at the<br />
forefront of the industry, and with a wide range<br />
of support packages available, your lab is covered –<br />
from product selection to implementation,<br />
application support and maintenance.
Infrared Spectroscopy<br />
QUICK-FIND INDEX Page #<br />
Autosampler and Sipper Supplies 242<br />
Demountable Cells and Windows 248<br />
Desiccant Kits 240<br />
Evacuable Potassium Bromide Die 258<br />
FT-NIR Cells and Supplies 249<br />
Liquid Sampling Cells<br />
and Supplies 246<br />
Microscopy Sampling<br />
Accessories and Supplies 252<br />
Potassium Bromide Presses 258<br />
Press-N-Lock Demountable<br />
Cell and Windows 250<br />
Reflectance Accessories 255<br />
Sampling Kits and Supplies 257<br />
Sealed Liquid Cells 250<br />
Semi-demountable Cells<br />
and Windows 251<br />
Short-path Demountable<br />
Gas Cells and Windows 245<br />
Solid Sampling Accessories<br />
and Supplies 258<br />
Spectrum Infrared Software 261<br />
Upgrade Kits 265<br />
PerkinElmer offers a wide selection of superior quality products designed to work with<br />
your PerkinElmer instruments. Our precision-designed products deliver the peace of<br />
mind that comes from knowing that you’ll get the results you need.<br />
The Quick Find Index to the left will help you find products fast. For your convenience,<br />
products are alphabetized by category, sub-category, and family. There is also a more<br />
complete Alphabetical INDEX on page 429 and a Part Number INDEX on page 407.<br />
Desiccant Kits<br />
Evacuable Potassium Bromide Die<br />
Manual Hydraulic Press<br />
Desiccant Kits are required for all PerkinElmer FT-IR<br />
spectrophotometers to keep the optical path free from<br />
moisture. It is recommended that the desiccant be replaced<br />
every six months. Please refer to the instrument operator's<br />
manual for correct installation instructions.<br />
Page 240<br />
Prepare 13 mm diameter Kbr pellets of the highest quality<br />
and clarity. The pellet is formed inside an evacuated<br />
chamber and pressed between a highly polished anvil and<br />
plunger. This die is precisely constructed to produce pellets<br />
of uniform quality and will continue to provide many years<br />
of service in your laboratory.<br />
Page 258<br />
This compact and easy-to-operate press is used with the<br />
KBr Die to prepare KBr pellets. The pressure is produced<br />
by operating a pump lever. The Press can also be used with<br />
Heated Platens for applications such as the preparation of<br />
thin polymer films.<br />
Page 258<br />
Universal Demountable Cell<br />
The Universal Demountable Cell is supplied without windows<br />
or spacers. Add Circular Windows (Page 248) to construct a<br />
Demountable Cell. Use Rectangular Windows (Page 251) to<br />
create a semi-demountable cell. A wide variety of window<br />
materials is available to suit your application needs.<br />
Page 248
A History of Innovation...<br />
a Vision for the Future<br />
For more than 60 years, PerkinElmer has<br />
been a world leader in IR spectroscopy,<br />
continually providing innovations designed<br />
to help laboratories produce accurate and<br />
reliable results with ease.<br />
Through industry firsts such as Absolute Virtual Instrument<br />
(AVI) and Atmospheric Vapor Compensation (AVC) and other<br />
patented technologies as well as in-depth IR training and<br />
unmatched service, PerkinElmer continues to deliver Infrared<br />
systems that meet your needs.<br />
Spectrum Spotlight<br />
From the introduction of the industry’s first IR model in<br />
1944 through the pioneering of modular sampling systems,<br />
PerkinElmer has continually advanced the technology of FT-IR<br />
spectroscopy. Our history of innovation continues with the<br />
Spectrum TM family of FT-IR and FT-NIR spectrometers.<br />
Spectrum BX<br />
Spectrum BX Systems are designed<br />
to meet the high validation standards<br />
set by QA/QC, method development<br />
and analytical service laboratories.<br />
All systems in the range offer fast<br />
throughput and rapid access to reliable<br />
and dependable FTIR results, day<br />
in and day out.<br />
Spectrum GX<br />
The Spectrum GX Systems set new<br />
performance standards for sophisticated<br />
research and development work and<br />
routine QA/QC applications. Its top<br />
signal-to-noise performance makes it<br />
the highest performing, research grade<br />
FTIR system available anywhere –<br />
offering unparalleled scope for growth.<br />
With Spectrum GX today’s system<br />
meets tomorrow’s needs.<br />
Spectrum RX<br />
If you work in a busy laboratory and<br />
need a dependable, rugged system<br />
which copes easily with the everyday<br />
challenges of routine applications, you<br />
should use one of our Spectrum RX<br />
Systems. Ideal for QA/QC and educational<br />
environments, they're fast, accurate,<br />
reliable and offer the only genuinely<br />
integrated, preconfigured solution to<br />
get you up and running fast.<br />
Spectrum 100 and Spectrum 100N<br />
Our history of innovation continues with<br />
the reliable, innovative Spectrum 100<br />
spectrometers. Featuring zero-alignment,<br />
easy-to-interchange accessories and<br />
integrated self-test routines, the<br />
Spectrum 100 and 100N systems offer<br />
quick, predictable and reproducible<br />
results – sample after sample.<br />
Spectrum Spotlight<br />
In the field of IR microscopy, PerkinElmer<br />
has been at the forefront since it introduced<br />
the first commercial IR microscope in<br />
1954. A continuous stream of PerkinElmer<br />
innovation has transformed the technique,<br />
made IR microscopy one of the most<br />
potent analytical tools, and established<br />
PerkinElmer FT-IR microscopes as the<br />
industry-standard. The Company’s<br />
breakthroughs in microscopy have set<br />
the benchmark for performance, software<br />
control, and ease of operation.<br />
PerkinElmer’s imaging systems allow large<br />
sample areas to be analyzed in minutes<br />
and seconds, rather than hours. The<br />
Spectrum Spotlight imaging systems’ high<br />
sensitivity allows the smallest samples to<br />
be detected while its IR imaging speed<br />
improves problem-solving time and<br />
redefines maximum measurement areas,<br />
revealing information not previously<br />
available and extending IR analysis to<br />
many new applications.<br />
239
Laboratory Products<br />
Desiccant and Maintenance Kits<br />
Infrared Spectroscopy Laboratory Products<br />
Beamsplitters<br />
KBr Beamsplitter<br />
Replacement Beamsplitter for Spectrum One/100 Systems.<br />
Service installation required, but not included.<br />
Csl Beamsplitter<br />
Replacement Beamsplitter for Spectrum One/100 Systems.<br />
Service installation required, but not included.<br />
Desiccant Kits<br />
Disposable Desiccant Kit Part No. N0171159<br />
These kits are required for all the PerkinElmer FT-IR<br />
Spectrometers to keep the optical path free from moisture.<br />
It is recommended that the desiccant is replaced every<br />
six months. Follow the instructions in the appropriate<br />
instrument manual to install the desiccant.<br />
Disposable Desiccant Kit<br />
User-installable desiccant, includes two desiccant packs.<br />
Four packs (two kits) required for each desiccant change.<br />
For use with Model 1600, Paragon 500, Paragon 1000,<br />
Spectrum TM 1000, Spectrum RX, and Spectrum BX. Also for<br />
Spectrum GX, Spectrum 2000, System 2000, Spectrum One,<br />
and Spectrum One NTS. Six packs<br />
(three kits) required for use with<br />
Part No. Each (€)<br />
Spectrum 100 and Spectrum 100N. N0171159 39<br />
Rechargeable Desiccant Kit for Spectrum One and<br />
Spectrum One NTS<br />
Includes four desiccant packs, two to<br />
use in the instrument and two spares<br />
for recharging.<br />
Part No.<br />
Part No.<br />
Each (€)<br />
L1200214 4026<br />
Part No.<br />
Each (€)<br />
L1200216 7200<br />
Each (€)<br />
L1200219 394<br />
Rechargeable Desiccant Kit for Spectrum<br />
1000/Spectrum RX/Spectrum BX/ Paragon<br />
500/Paragon 1000/Model 1600<br />
Includes one desiccant pack. One pack<br />
required for each desiccant change.<br />
Rechargeable Desiccant Kit for Model 1700<br />
Includes one desiccant pack. One pack<br />
required for each desiccant change.<br />
Rechargeable Desiccant Kit for Spectrum GX/<br />
Spectrum 2000/System 2000 FT-IR Optical Units<br />
Includes one desiccant pack. One pack<br />
required for each desiccant change.<br />
Rechargeable Desiccant Kit for Spectrum GX/<br />
Spectrum 2000 Detector Area/System 2000<br />
Includes one desiccant pack. One pack<br />
required for each desiccant change.<br />
Maintenance Kits<br />
Spectrum One NTS Maintenance Kit<br />
Includes spare Source Lamp and<br />
Desiccant recommended for 6-12<br />
monthly maintenance operations.<br />
Spectrum IdentiCheck Maintenance Kit<br />
Includes spare source lamp<br />
and desiccant.<br />
Laser Head (HeNe) and Laser Power Supply<br />
User-installable spare for<br />
Spectrum One/100 and Spectrum<br />
One NTS/100N systems.<br />
Part No.<br />
Each (€)<br />
L1180480 197<br />
Part No.<br />
Each (€)<br />
L1160333 347<br />
Part No.<br />
Each (€)<br />
04994506 307<br />
Part No.<br />
Each (€)<br />
04994507 574<br />
Part No.<br />
Part No.<br />
Each (€)<br />
L1180486 221<br />
Part No.<br />
Each (€)<br />
L1240097 185<br />
Each (€)<br />
L1200253 1268<br />
240
Laboratory Products<br />
Source Lamps and Standards<br />
Source Lamps<br />
TG/IR and GC/IR Supplies<br />
Source Lamp for Spectrum One NTS/100N<br />
User-installable spare for<br />
Spectrum One NTS/100N Systems.<br />
Source Lamp for Spectrum One/100<br />
User-installable spare for<br />
Spectrum One/100 Systems.<br />
Standards<br />
Spectralon Reference Standards Set (Calibrated)<br />
For use with the Spectrum One NTS/100N Reflectance<br />
Accessory and the IdentiCheck Reflectance Accessory.<br />
Includes calibrated standards for<br />
reflective values of 99, 75, 50, and 2%.<br />
Part No. Each (€)<br />
L1181322 5400<br />
Thin Test Films<br />
These thin polymer films, sealed in cardboard mounts,<br />
serve as easy-to-use standards which are stable with time.<br />
Use them to check frequency accuracy and to monitor any<br />
changes in the overall performance of the spectrometer.<br />
Mounted films of polystyrene and Teflon ® are available,<br />
0.038 and 0.05 mm thick, respectively.<br />
Polystyrene Test Film<br />
0.038 mm, mounted.<br />
Teflon Test Film<br />
0.05 mm.<br />
Part No.<br />
Each (€)<br />
L1240098 179<br />
Part No.<br />
Each (€)<br />
L1200406 1208<br />
Part No.<br />
Each (€)<br />
L1202057 16<br />
Part No.<br />
Each (€)<br />
L1181056 5<br />
The removable inert linings of the cell and transfer<br />
line can be replaced with the spares supplied with the<br />
TG/IR Maintenance Kit. Potassium bromide and zinc<br />
selenide replacement infrared windows for the gas cell<br />
are also available.<br />
TG/IR Maintenance Kit<br />
Includes cell inner body, heater line<br />
inner tube (1,500 mm), selection<br />
of O-Rings, and fuses.<br />
KBr Windows for Gas Cell<br />
ZnSe Windows for Gas Cell<br />
PEEK Cell Liner<br />
Heated Line Inner Tube<br />
Test Mix-FID for GC/IR<br />
Part No.<br />
Each (€)<br />
L1362300 365<br />
Part No.<br />
Each (€)<br />
04978581 606<br />
Part No.<br />
Each (€)<br />
04978582 1471<br />
Part No.<br />
Each (€)<br />
L1362307 167<br />
Part No.<br />
Each (€)<br />
04978590 161<br />
Part No.<br />
Each (€)<br />
L4831520 57<br />
Laboratory Products Infrared Spectroscopy<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
241
Infrared Spectroscopy Sampling Accessories and Supplies<br />
Sampling Accessories and Supplies<br />
Autosampler and Sipper Supplies<br />
Autosampler Accessories<br />
Drip Tray for FT-NIR<br />
Flush Port Lid O-Ring for FT-NIR<br />
Fuses (2A time delay) for FT-NIR<br />
Insulation Block<br />
for Spectrum OilExpress<br />
Non-Return Valve for FT-NIR<br />
Sample Probe<br />
for Spectrum OilExpress<br />
Solvent Bottle and Cap (drilled)<br />
for FT-IR and FT-NIR<br />
Solvent Filter for FT-NIR<br />
Autosampler Flowcells,<br />
Windows, and Supplies<br />
FT-IR Flowcell<br />
0.1 mm pathlength, wedged Spacer,<br />
ZnSe Windows (one grooved),<br />
and three ports.<br />
OilExpress Flowcell<br />
0.1 mm pathlength, wedged Spacer,<br />
ZnSe Windows (one grooved), and<br />
two ports. Optimized for the sampling<br />
L1191202 2201<br />
of viscous fluids and to reduce interference fringes.<br />
ZnSe Windows for FT-IR and<br />
Spectrum OilExpress Flowcell<br />
Fitted to ensure moisture resistance.<br />
Part No.<br />
Each (€)<br />
L1191014 132<br />
Part No.<br />
Each (€)<br />
09921037 2<br />
Part No.<br />
Each (€)<br />
04970839 1<br />
Part No.<br />
Each (€)<br />
L1200558 261<br />
Part No.<br />
Part No.<br />
Each (€)<br />
L1200555 969<br />
Part No.<br />
Each (€)<br />
L1195019 62<br />
Part No.<br />
Each (€)<br />
04970573 114<br />
Each (€)<br />
09903615 68<br />
Part No.<br />
Each (€)<br />
L1191080 2201<br />
Part No.<br />
Part No.<br />
Each (€)<br />
Each (€)<br />
L1191081 1256<br />
Gaskets and Spacers for FT-IR<br />
and Spectrum OilExpress Flowcell<br />
FT-NIR Flowcell<br />
1 mm pathlength, quartz, and 2-ports.<br />
Gasket Set for FT-NIR Flowcell -<br />
1 mm 2-port<br />
(pkg. 10)<br />
Gasket Set for FT-NIR Flowcell -<br />
0.5 mm 2-port<br />
(pkg. 10)<br />
Autosampler Sample Cassettes<br />
and Vials for FT-IR and FT-NIR<br />
Additional sample cassettes can be purchased for the FT-IR<br />
Liquid Autosampler. For greater productivity, one cassette<br />
can be used for analysis while others are being loaded.<br />
Autosampler Vial Cassette<br />
Holds 50 tubes, 16.8 x 67 mm.<br />
Autosampler Vial Cassette<br />
Holds 100 tubes, 16.8 x 67 mm.<br />
Plastic Autosampler Vials<br />
for FT-IR and FT-NIR<br />
Pack of 1000 vials<br />
Caps for FT-NIR Glass Vials<br />
Pack of 144 caps<br />
Septa for FT-NIR Glass Vials<br />
Pack of 100 Septa<br />
Part No.<br />
Each (€)<br />
L1191082 61<br />
Part No.<br />
Each (€)<br />
L1191207 1531<br />
Part No.<br />
Each (€)<br />
L1191099 132<br />
Part No.<br />
Each (€)<br />
L1191113 132<br />
Part No.<br />
Each (€)<br />
L1191021 2081<br />
Part No.<br />
Each (€)<br />
L1191018 3002<br />
Part No.<br />
Each (€)<br />
L1191079 132<br />
Part No.<br />
Each (€)<br />
L1191210 85<br />
Part No.<br />
Each (€)<br />
L1191211 74<br />
242
Autosampler Sample Racks<br />
for Spectrum OilExpress<br />
Additional sample racks can be purchased for the Spectrum<br />
OilExpress Autosampler. There is a choice of sample test<br />
tube or sample bottle racks depending on the sampling<br />
requirements. Also, for greater productivity, one rack can<br />
be used for analysis while others are being loaded.<br />
Autosampler Oil Bottle Rack<br />
Additional 30-position, 4 oz bottle rack to allow the<br />
preparation of the next rack while a run is in progress.<br />
Allows sample presentation in standard sample<br />
collection vessels, reducing the amount<br />
of sample preparation required.<br />
Part No. Each (€)<br />
L1200551 981<br />
Autosampler Test Tube Racks 16 x 6<br />
Allows interchangeable sampling<br />
between test-tube vials and<br />
4 oz bottles.<br />
Autosampler Syringe<br />
and Needle Supplies<br />
Needle for FT-IR and FT-NIR<br />
Needle O-Ring for FT-IR and FT-NIR<br />
(pkg. 5)<br />
Needle Spring for FT-IR and FT-NIR<br />
(pkg. 5)<br />
10 mL Syringe with Plunger<br />
for Spectrum OilExpress<br />
Seal Kit for Spectrum OilExpress<br />
Contains four user replaceable<br />
syringe piston noses.<br />
Lubrication Kit for Syringe Pump<br />
Screw Drive for Spectrum OilExpress<br />
Syringe Clamps for Spectrum OilExpress<br />
Clamps to prevent Syringe barrel<br />
from moving.<br />
Part No.<br />
Sampling Accessories and Supplies<br />
Each (€)<br />
L1200589 921<br />
Part No.<br />
Each (€)<br />
L1191031 47<br />
Part No.<br />
Each (€)<br />
L1003012 3<br />
Part No.<br />
Each (€)<br />
L1003018 12<br />
Part No.<br />
Each (€)<br />
L1200552 137<br />
Part No.<br />
Each (€)<br />
L1200553 66<br />
Part No.<br />
Each (€)<br />
L1200559 33<br />
Part No.<br />
Each (€)<br />
L1200574 80<br />
Autosampler and Sipper Supplies<br />
Autosampler Tubing<br />
Peristaltic Pump Tubing<br />
Length Material Application Part No. Each(€)<br />
3 m Tygon ® 4040A FT-IR, FT-NIR, L1191015 62<br />
OilExpress<br />
3 m Tygon R-3603 FT-NIR 02507999 9<br />
3 m PharMed TM FT-NIR L1191114 35<br />
Waste Tubing<br />
Application Part No. Each(€)<br />
OilExpress L1200560 27<br />
FT-NIR 02508065 10<br />
Tubing for Needle and Connections<br />
in Front Panel for FT-IR and FT-NIR<br />
1 m, Teflon ® Tube, 2 mm i.d.<br />
Ferrules for Ends of Teflon<br />
Tubing for FT-IR and FT-NIR<br />
For front panel and flowcell<br />
connections, 1/8 in. Tefzel. (pkg. 5)<br />
Nuts for Ends of Teflon<br />
Tubing for FT-IR and FT-NIR<br />
For front panel and flowcell<br />
connections, 1/8 in. (pkg. 5)<br />
Tube Flanging Kit<br />
Sample Needle Tubing<br />
for Spectrum OilExpress<br />
Flowcell to Syringe Tubing<br />
for Spectrum OilExpress<br />
Solvent to Syringe Tubing<br />
for Spectrum OilExpress<br />
(pkg. 2)<br />
Injection/Transfer Port to Flowcell<br />
Tubing for Spectrum OilExpress<br />
Part No.<br />
Each (€)<br />
02508063 10<br />
Part No.<br />
Part No.<br />
Part No.<br />
Each (€)<br />
09923337 263<br />
Part No.<br />
Each (€)<br />
L1200587 44<br />
Part No.<br />
Each (€)<br />
L1200588 49<br />
Part No.<br />
Each (€)<br />
L1200556 44<br />
Part No.<br />
Each (€)<br />
L1003021 18<br />
Each (€)<br />
L1003020 18<br />
Each (€)<br />
L1200557 44<br />
Sampling Accessories and Supplies Infrared Spectroscopy<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
243
Infrared Spectroscopy Sampling Accessories and Supplies<br />
Sampling Accessories and Supplies<br />
Autosampler and Sipper Supplies<br />
Sipper Cells and Windows<br />
for the Spectrum One/100<br />
Demountable Sipper Cell Kit – No Windows<br />
Allows cells to be made up with different window materials<br />
and pathlengths to suit specific applications. Choose from the<br />
windows and spacers listed below.<br />
Part No. Each (€)<br />
Sipper Cell Windows<br />
For use with the Demountable Sipper Cell Kit. Includes one<br />
grooved and one plain window.<br />
Window Material Part No. Each (€)<br />
KBr L1200308 610<br />
CaF 2 L1200309 803<br />
BaF 2 L1200310 829<br />
Sipper Cell Spacers<br />
For use with the Demountable Sipper Cell Kit.<br />
Width Part No. Each (€)<br />
50 Microns L1201904 14<br />
100 Microns L1201905 14<br />
Sipper Cells and Windows<br />
for the Spectrum One NTS/100N<br />
Quartz Sipper Cell Inlet Window<br />
Quartz Sipper Cell Plain Window<br />
Cell Spacer 0.5 mm<br />
L1200306 217<br />
Part No.<br />
Each (€)<br />
L1202715 234<br />
Part No.<br />
Each (€)<br />
L1202716 234<br />
Part No.<br />
Each (€)<br />
L1201231 2<br />
Sipper Supplies<br />
Sipper Pump Tubing<br />
Complete with hose barb connectors.<br />
Material Part No. Each (€)<br />
Viton L1202006 13<br />
Autoprene L1202035 13<br />
Silicone L1202036 13<br />
Tygon ® L1202037 13<br />
Teflon Tubing (1 m)<br />
Used for internal connection<br />
between Sipper pump and cell.<br />
Ferrule (Tefzel)<br />
Used for Sipper tube connection. (pkg. 5)<br />
Nut Flange for Ferrule<br />
Used for Sipper tube connection. (pkg. 5)<br />
Filter<br />
Used for filtering solid particulates<br />
from the liquid sample.<br />
Tablet Autosampler Supplies<br />
Part No.<br />
Each (€)<br />
02508063 10<br />
Part No.<br />
Each (€)<br />
L1003021 18<br />
Part No.<br />
Each (€)<br />
L1003020 18<br />
Part No.<br />
Each (€)<br />
L1201989 167<br />
The Spectrum FT-NIR Systems Tablet Autosampler is ideal<br />
for tablet identification, tablet assays, and content uniformity<br />
of tablet batches. It can also be used as a Near Infrared<br />
Reflectance Accessory for analyzing a wide range of sample<br />
types in various containers.<br />
244
Custom Tablet Moulds Resin Kit<br />
Includes resin, accelerator, and release agent to make<br />
approximately 200 custom moulds.<br />
Part No. Each (€)<br />
Tablet Setting Pin<br />
Size Pkg. Part No. Each (€)<br />
6 mm 5 L1241555 18<br />
4 mm 5 L1241559 18<br />
Tablet Mould<br />
Size Pkg. Part No. Each (€)<br />
6 mm 5 L1241557 6<br />
4 mm 5 L1241558 6<br />
Tablet Mould Base<br />
(pkg. 5)<br />
Disposable Syringe<br />
Size Pkg. Part No. Each (€)<br />
1 mm 100 09200010 300<br />
10 mm 100 09200011 345<br />
Syringe Nozzle<br />
(pkg. 50)<br />
Tablet Holder<br />
Size Pkg. Part No. Each (€)<br />
8 mm 5 L1241571 7<br />
9 mm 5 L1241572 7<br />
10 mm 5 L1241573 7<br />
11 mm 5 L1241574 7<br />
12 mm 5 L1241575 15<br />
4 mL Glass Vial with Cap,<br />
15 x 45 mm<br />
(pkg. 100)<br />
Beaker, 100 mL Tri-Corner<br />
(pkg. 100)<br />
Spatula<br />
(pkg. 3)<br />
Sampling Accessories and Supplies<br />
L1245024 371<br />
Part No.<br />
Each (€)<br />
L1241556 49<br />
Part No.<br />
Each (€)<br />
09200013 187<br />
Part No.<br />
Each (€)<br />
L9001029 78<br />
Part No.<br />
Each (€)<br />
09200012 102<br />
Part No.<br />
Each (€)<br />
09200017 33<br />
Autosampler and Gas Sampling Supplies<br />
Short-path Demountable<br />
Gas Cells and Windows<br />
PerkinElmer offers Short-path Demountable Cells to<br />
monitor air pollutants, study vapor phase transitions in<br />
gas molecules, and quantify impurities in gas samples.<br />
These 10 cm cells have been designed for use on all<br />
PerkinElmer infrared instruments.<br />
Removable Windows for Easy Cleaning<br />
Reactive gases may fog or attack the window material, but<br />
the windows can be removed easily and repolished.<br />
Stopcocks for filling and purging the cell are an integral<br />
part of the cell body. The cells should not be subjected to<br />
pressures of more than one atmosphere. The cell has a<br />
volume of approximately 120 mL.<br />
The cell is supplied with windows, and spare windows can<br />
be ordered separately. A Universal 10 cm Gas Cell Mount is<br />
required to mount the accessory in the sample slide of the<br />
instrument and must be ordered separately.<br />
10 cm Short-path Demountable<br />
Gas Cells with Windows<br />
Window Material Part No. Each (€)<br />
NaCl 51000634 546<br />
KBr 51000636 616<br />
CaF 2 51000638 616<br />
47 mm Replacement Windows<br />
Window Material Qty. Part No. Each (€)<br />
NaCl 2 51000635 176<br />
KBr 2 51000637 301<br />
CaF 2 2 51000639 667<br />
Universal 10 cm Gas Cell Mount<br />
Gaskets for 10 cm Gas Cells<br />
Part No.<br />
Each (€)<br />
51000817 103<br />
Part No.<br />
Each (€)<br />
51012725 51<br />
Sampling Accessories and Supplies Infrared Spectroscopy<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
245
Sampling Accessories and Supplies<br />
Liquid Sampling Cells and Supplies<br />
PerkinElmer Liquid Sampling Cells<br />
and Window Materials<br />
PerkinElmer offers a wide selection<br />
of liquid sampling cells and<br />
window materials.<br />
PerkinElmer offers a versatile product line of liquid<br />
sampling cells which utilize a specially designed<br />
Universal mount suitable for both FT-IR and dispersive<br />
instruments, and a wide variety of high-quality window<br />
materials to meet your analytical needs. These windows<br />
are polished to precise tolerances of flatness.<br />
The first criteria to consider when selecting a<br />
window material is the wavelength range over which<br />
the spectrum must be measured.<br />
Sealed Cell and Demountable Cell<br />
Other important considerations include solubility,<br />
reactivity, and the refractive index of the window<br />
material with respect to the sample. Sometimes<br />
mechanical and thermal characteristics may also<br />
be important.<br />
Solubility<br />
Transmission Refractive Index G/100 G H 2 0<br />
Window Material Refractive Range μm cm -1 at 1000 cm -1 at 20 °C<br />
Sodium Chloride, NaCl 0.25 - 16 40,000 - 625 1.49 36.0<br />
Potassium Bromide, KBr 0.25 - 26 40,000 - 385 1.52 65.2<br />
Potassium Chloride, KCl 0.25 - 20 40,000 - 500 1.46 34.7<br />
Cesium Iodide, CsI 0.30 - 50 33,000 - 200 1.74 160.0 (at 61 °C)<br />
Fused Silica, Si0 2 0.20 - 4 50,000 - 2,500 1.42 (at 3,333 cm -1 ) Insoluble<br />
Calcium Fluoride, CaF 2 0.20 - 9 50,000 - 1,100 1.39 (at 2,000 cm -1 ) 1.51 x 10 -3<br />
Barium Fluoride, BaF 2 0.20 - 13 50,000 - 770 1.42 0.12 (at 25 °C)<br />
Thallium Bromide-Iodide, KRS-5 0.60 - 40 16,600 - 250 2.37 < 4.76 x 10 -2<br />
Silver Bromide, AgBr 0.50 - 35 20,000 - 285 2.00 12 x 10 -6<br />
Zinc Sulfide, ZnS (Cleartran) 1.0 - 14 10,000 - 715 2.20 Insoluble<br />
Zinc Selenide, ZnSe (Irtran-4) 1.0 - 19.5 10,000 - 515 2.41 Insoluble<br />
Polyethylene (high-density) 16 - 333 625 - 30 1.54 (at 5,000 cm -1 ) Insoluble<br />
246
Sampling Accessories and Supplies<br />
Liquid Sampling Cells and Supplies<br />
PerkinElmer offers a variety of cell<br />
options for analyzing liquid samples.<br />
Liquids are traditionally analyzed as thin films in cells. A cell consists<br />
of two FT-IR transparent windows. A Teflon spacer is generally<br />
used to produce a film of the desired thickness or pathlength.<br />
Demountable Cells – using circular windows, the Universal<br />
Demountable Cell is ideal for use with mulls, capillary films,<br />
cast films and very viscous liquids.<br />
Semi-demountable Cells – using rectangular windows, the Universal<br />
Demountable Cell is designed for use with high viscosity liquids<br />
or mull samples.<br />
Sealed Liquid Cells – designed as a preassembled, integral unit,<br />
Sealed Liquid Cells are great for highly volatile samples and<br />
quantitative analysis.<br />
Press-N-Lock Demountable Cells – eliminates the need for nuts, springs,<br />
and bolts to keep the cell together.<br />
Press-N-Lock Demountable Cell Part No. N9302642<br />
PerkinElmer cells feature both rugged construction and flexibility.<br />
All can easily be cleaned for re-use and, depending on the cell you<br />
choose, can be disassembled so that cell windows can be cleaned<br />
and polished regularly.<br />
PerkinElmer also offers<br />
FT-NIR Cells which are<br />
available in a wide range<br />
of configurations and<br />
lightpaths.<br />
The following information may be helpful in selecting window materials:<br />
Sodium Chloride (NaCl)<br />
NaCl is one of the most versatile window materials available, due to<br />
its spectral range and low cost. Samples should not contain water<br />
because NaCl is hygroscopic. This will cause the windows to fog and<br />
become unusable. Store NaCl cells in a desiccator when not in use.<br />
NaCl withstands mechanical stress and can be used up to 400 °C.<br />
Potassium Bromide (KBr)<br />
KBr has a slightly wider spectral range than NaCl but is more<br />
hygroscopic. Although able to provide good resistance to mechanical<br />
shock, KBr is easily cleaved. KBr can be used up to 300 °C.<br />
Cesium Iodide (CsI)<br />
CsI has an extended spectral range relative to NaCl and KBr.<br />
However, CsI is very hygroscopic and is soft material that can be<br />
scratched easily. CsI does not cleave, reacts with many organic<br />
compounds, and can withstand rapid temperature changes.<br />
Calcium Fluoride (CaF 2 )<br />
CaF 2 is extremely hard and stable. CaF 2 is not significantly affected<br />
by moisture and does not fog. While resistant to most acids and<br />
bases, CaF 2 should not be used with ammonium salts.<br />
Barium Fluoride (BaF 2 )<br />
BaF 2 is a relatively hard material, similar to CaF 2 . Though less<br />
resistant to water than CaF 2 , BaF 2 has a wider spectral range. The<br />
useful temperature range extends to 500 °C. Also, BaF 2 should not<br />
be used with ammonium salts.<br />
Thallium Bromide-Iodide (KRS-5)<br />
KRS-5 has a broad spectral range and a high refractive index,<br />
making it ideal for internal reflectance accessories. KRS-5 is<br />
slightly soluble in water and bases but insoluble in acids; KRS-5<br />
is toxic and should not be repolished.<br />
Silver Bromide (AgBr)<br />
AgBr is easily scratched and has a tendency to cold flow at room<br />
temperature. Although only minimally degraded by water, AgBr will<br />
corrode after prolonged contact with moisture and metals. Avoid<br />
exposure to ultraviolet lights, as the crystal has a tendency to darken.<br />
Zinc Sulfide (Cleartran TM )<br />
Cleartran is relatively hard and has a high refractive index. Cleartran<br />
is insoluble in water but is slightly attacked by acids and strong bases.<br />
Zinc Selenide (Irtran-4 TM )<br />
Irtran-4 is similar to Cleartran except that it is somewhat softer<br />
and more easily scratched. Irtran-4 is used in total reflectance<br />
accessories because of its high refractive index.<br />
Fused Silica (SiO 2 )<br />
Infrared grade SiO 2 has a useful spectral range extending into<br />
the near infrared. Although insoluble in water, SiO 2 is resistant<br />
to mechanical and thermal stress.<br />
Polyethylene<br />
Polyethylene is a window material for the far infrared. Although it<br />
has a broad absorption band at about 70 cm -1 , polyethylene can be<br />
used to 10 cm -1 . The principal disadvantage with polyethylene is<br />
that its lack of rigidity makes cell thickness difficult to control. In<br />
addition, polyethylene cell windows are difficult to clean.<br />
FT-NIR Cells<br />
www.perkinelmer.com/<strong>supplies</strong> 247
Infrared Spectroscopy Sampling Accessories and Supplies<br />
Sampling Accessories and Supplies<br />
Liquid Sampling Cells and Supplies<br />
Demountable Cell<br />
Crystal Polishing Kit<br />
Crystal Polishing Kit<br />
Fogged windows are quickly restored to perfect condition<br />
with the infrared crystal polishing kit. The kit contains<br />
everything necessary to repolish sodium chloride,<br />
potassium bromide, or cesium iodide windows, and<br />
includes a smoothing lap, polishing rouge, a sponge,<br />
an optical flat, a Selvyt cloth, and a booklet describing<br />
the repolishing technique. Special self-adhesive Selvyts<br />
that stick to the polishing lap are also<br />
supplied; this keeps the Selvyt flat and Part No. Each (€)<br />
makes replacement quick and simple.<br />
51001188 342<br />
Replacement Parts for the Crystal Polishing Kit<br />
The following parts are included in the Crystal Polishing<br />
Kit, but are also available separately:<br />
Description Part No. Each (€)<br />
Selvyt Cloth (pkg. 5) 51001324 90<br />
Glass Grinding Lap 51001325 73<br />
Optical Lap 51001326 73<br />
Cleaning Sponge (pkg. 2) 51001327 51<br />
Tin Polishing Rouge, 56 g 51001328 94<br />
Polishing Lap Glass Plate 51001329 51<br />
Demountable Cells and Windows<br />
For Mulls, Capillary Films, Cast Films,<br />
and Very Viscous Liquids<br />
Circular windows are used to<br />
construct a demountable cell<br />
where the sample is placed on<br />
one window and the second<br />
window is pressed lightly on<br />
top of the first. Spacers of various<br />
thicknesses can be used to vary<br />
the cell pathlength.<br />
Universal Demountable<br />
Cell Mount<br />
Includes top and back plates.<br />
The Universal Demountable Cell<br />
is supplied without windows or<br />
spacers – circular windows and<br />
spacers should be ordered<br />
separately. A thicknesscompensating<br />
spacer is required<br />
for 2 mm thick windows. The<br />
windows are demountable and<br />
can be easily changed and<br />
repolished when necessary.<br />
Part No.<br />
Each (€)<br />
L1270986 299<br />
Demountable Cell Parts<br />
Components Part No. Each (€)<br />
1<br />
Back Plate<br />
23 Window Aligner 04821132 12<br />
31 Neoprene TM Gasket L1270512 15<br />
43 Circular Window (see product listing below)<br />
53 Spacer (see product listing below)<br />
63 Top Plate<br />
74 Teflon ® Plugs (pkg. 6) 04821008 6<br />
82 Quick Release Nut 04821131 14<br />
1 2 3 4 5 4<br />
Circular Demountable Cell Windows (Pair)<br />
Window Material Diameter Thickness Part No. Each (€)<br />
Sodium Chloride 25 mm 4 mm L1271102 82<br />
Potassium Bromide 25 mm 4 mm L1271202 136<br />
Calcium Fluoride 25 mm 4 mm L1271602 617<br />
Barium Fluoride 25 mm 4 mm L1272002 660<br />
Thallium Bomide-Iodide 25 mm 4 mm L1270665 688<br />
Silver Bromide 25 mm 2 mm L1272102 518<br />
Zinc Selenide 25 mm 2 mm L1270766 919<br />
Circular Spacers for Circular<br />
Demountable Cell Windows<br />
Spacer Material Thickness Qty. Part No. Each (€)<br />
Lead 0.025 mm 10 L1271250 72<br />
Teflon* 0.05 mm 10 51001135 59<br />
Teflon* 0.1 mm 6 51001137 59<br />
Teflon* 0.2 mm 3 51001140 59<br />
Teflon* 0.5 mm 3 51001141 63<br />
* Teflon spacers can be used for the analysis of less viscous samples.<br />
6<br />
7<br />
8<br />
248
FT-NIR Cells and Supplies<br />
PerkinElmer offers a<br />
comprehensive range of FT-NIR<br />
Cells, cell holders, and <strong>supplies</strong>.<br />
The range includes Cylindrical<br />
Cells, Rectangular Cells, Semimicro<br />
Cells, and Micro Cells.<br />
These cells are suitable for use<br />
with all PerkinElmer FT-NIR<br />
Spectrometers.<br />
FT-NIR Cylindrical Cells<br />
Material Lightpath mm Qty. Part No. Each (€)<br />
Fused Silica 2 1 L1181301 231<br />
Fused Silica 5 1 L1181302 266<br />
Quartz Suprasil 300 10 1 B0631099 97<br />
Quartz Suprasil 300 20 1 B0631100 97<br />
Quartz Suprasil 300 50 1 B0631101 129<br />
Quartz Suprasil 300 100 1 B0631102 143<br />
FT-NIR Cylindrical Cell Holders<br />
Lightpath mm Qty. Part No. Each (€)<br />
10 1 L1181303 257<br />
50 1 N9302620 159<br />
100 1 N9302640 133<br />
FT-NIR Rectangular Cells<br />
Lightpath<br />
Material mm Cap Qty. Part No. Each (€)<br />
Quartz Suprasil 300 1 Lid 2 B0631013 327<br />
Fused Silica 2 Lid 1 L1181304 121<br />
5 Lid 2 B0631014 177<br />
10 Lid 2 B0631015 160<br />
20 Lid 2 B0631016 332<br />
Quartz Suprasil 300 50 Lid 1 B0631017 218<br />
100 Lid 1 B0631018 200<br />
1 Stopper 2 B0631031 399<br />
5 Stopper 2 B0631032 356<br />
10 Stopper 2 B0631033 179<br />
20 Stopper 2 B0631034 200<br />
50 Stopper 2 B0631035 250<br />
100 Stopper 1 B0631036 467<br />
Quartz Infrasil 5 Stopper 2 52001539 187<br />
50 mm FT-NIR Rectangular<br />
Cell Holder<br />
Semi-Micro Rectangular Cells<br />
Part No.<br />
Lightpath mm Cap Qty. Part No. Each (€)<br />
10 Lid 2 B0631051 451<br />
20 Lid 2 B0631045 422<br />
5 Stopper 2 B0631065 489<br />
10 Stopper 2 B0631066 489<br />
20 Stopper 2 B0631060 385<br />
Sampling Accessories and Supplies<br />
Each (€)<br />
02200550 103<br />
Liquid Sampling Cells and Supplies<br />
Micro Rectangular Cell<br />
Material Lightpath mm Cap Qty. Part No. Each (€)<br />
Quartz Suprasil 300 10 Stopper 2 B0631078 709<br />
Spare Lids and Stoppers<br />
Description Part No. Each (€)<br />
5 mm PTFE Lid B0631145 4<br />
10 mm PTFE Lid B0631129 2<br />
Stopper, NS7 Fitting, PTFE B0631128 3<br />
Stopper, PTFE B0631149 3<br />
FT-NIR FT-Raman Sampling Accessory Kit<br />
Developed to ensure that you obtain the best possible spectrum<br />
for virtually any sample, the kit is comprised of four sampling<br />
devices designed to be used interchangeably without<br />
realignment between samples. These accessories provide<br />
reproducible sample positioning essential for quantitative<br />
studies. Each accessory is matched with the Raman collection<br />
optics and will enhance the signal-to-noise by factors of 2 to 4.<br />
Compatible with the 1700X Series FT-NIR FT-Raman<br />
spectrometer, the System 2000R,<br />
Spectrum 2000R, and the<br />
Spectrum GX Raman.<br />
Part No.<br />
L1304040<br />
Each (€)<br />
3493<br />
Low-Volume Liquid Spheres<br />
For use with the FT-Raman Sampling<br />
Accessory. (pkg. 50)<br />
FT-NIR Disposable Cells and Holders<br />
for the Spectrum One NTS/100N<br />
Disposable Snap-Cells<br />
Fully assembled for the convenient analysis of liquid samples.<br />
Includes cell holder, Snap-cells, glass cell windows, and a<br />
1 mL pipette for sample introduction. Pathlength ca 0.5 mm.<br />
Snap-Cell (Qty.) Glass Cell Windows (Qty.) Part No. Each (€)<br />
Pack of 5 10 L1240056 32<br />
Pack of 100 200 L1240057 592<br />
Molded Flexible Cuvette Holder<br />
in Transmission Cell Slide<br />
For rectangular cuvettes of pathlength<br />
0.5 - 20 mm or ca 11 mm diameter<br />
disposable vials.<br />
Part No.<br />
Part No.<br />
Each (€)<br />
L1871106 437<br />
Each (€)<br />
L1240055 35<br />
Sampling Accessories and Supplies Infrared Spectroscopy<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
249
Infrared Spectroscopy Sampling Accessories and Supplies<br />
Sealed Cell<br />
Sampling Accessories and Supplies<br />
Liquid Sampling Cells and Supplies<br />
Press-N-Lock Demountable<br />
Cell and Windows<br />
For Simple Analysis of Mulls, Smears, and Viscous Films<br />
The Press-N-Lock Demountable Cell lets you analyze<br />
mulls, smears, viscous films, etc., without the use of<br />
nuts, springs, or bolts to keep the cell together. You<br />
can use this cell on any PerkinElmer FT-IR<br />
spectrometer. The cell consists of a<br />
backplate with a Viton O-Ring that<br />
lets you slip the cover on and off<br />
with ease.<br />
Press-N-Lock Demountable Cell<br />
Press-N-Lock Cell O-Rings<br />
25 mm (pkg. 12).<br />
Press-N-Lock Demountable Cell Windows (Pair)<br />
Window Material Diameter Thickness Part No. Each (€)<br />
NaCl 25 mm 4 mm L1271102 82<br />
KBr 25 mm 4 mm L1271202 136<br />
BaF 2 25 mm 4 mm L1272002 660<br />
ZnSe 25 mm 2 mm L1270766 919<br />
CaF 2 25 mm 4 mm L1271602 617<br />
Sealed Liquid Cells<br />
Part No.<br />
For Highly Volatile Samples and Quantitative Analysis<br />
Each (€)<br />
N9302642 123<br />
Part No.<br />
Each (€)<br />
N9302643 44<br />
The sealed liquid cells have a corrosion-resistant construction,<br />
making them ideal for highly volatile samples. Each sealed<br />
liquid cell has a precise pathlength which is calibrated using<br />
the interference pattern generated by an empty cell in the<br />
beam of a spectrometer. The sealed liquid cells are ideal<br />
for quantitative analysis where you require an accurate<br />
reproducible cell thickness. These cells use a lead spacer<br />
which is amalgamated to the window<br />
material. The resultant bond forms a<br />
good leak-free seal which is effective<br />
in preventing evaporation and loss of<br />
sample. You can fill or empty liquid<br />
samples easily. The sealed liquid cell<br />
is an integral unit and cannot<br />
be disassembled.<br />
Rugged construction<br />
Easy to fill and clean<br />
Leak-free operation<br />
Calibrated for quantitative analysis<br />
Usable on all PerkinElmer FT-IR spectrometers<br />
Holds Highly Volatile Samples<br />
The amalgam seal between the windows will hold even low<br />
boiling samples, such as ethyl ether, through a spectral scan.<br />
You can use the 0.025 mm thickness cells for highly polar,<br />
pure liquids. The 0.1 - 0.2 mm thick cells are designed for<br />
samples that are weak absorbers of infrared energy.<br />
Easy to Fill and Clean<br />
The sample filling orifice is compatible with Luer-Lok<br />
hypodermic syringes. Two syringes are recommended<br />
when cleaning the cell. Never use viscous materials which<br />
are difficult to remove from a sealed liquid cell. Instead,<br />
use a semi-demountable cell.<br />
Variety of Window Materials Available<br />
Different window materials are available to accommodate<br />
your wavelength range requirements and to permit working<br />
with aqueous and non-aqueous samples.<br />
Sealed cells come with the windows and pathlength specified.<br />
Each cell includes a pair of Teflon plugs. Simply order the<br />
cell configuration you want using a single part number. All<br />
sealed cells use rectangular windows. The cells are calibrated<br />
and shipped in desiccated and sealed plastic containers.<br />
Rectangular Sealed Liquid Cells<br />
Window Material Pathlength Part No. Each (€)<br />
Sodium Chloride 0.025 mm L1270941 321<br />
0.05 mm L1270942 321<br />
0.1 mm L1270944 321<br />
0.2 mm L1270947 289<br />
0.5 mm L1270948 321<br />
1 mm L1270949 321<br />
Potassium Bromide 0.025 mm L1270951 330<br />
0.05 mm L1270952 330<br />
0.1 mm L1270954 366<br />
0.2 mm L1270957 366<br />
0.5 mm L1270958 366<br />
1 mm L1270959 312<br />
Calcium Fluoride 0.025 mm L1270961 570<br />
0.05 mm L1270962 570<br />
0.1 mm L1270964 570<br />
0.2 mm L1270967 570<br />
0.5 mm L1270968 856<br />
1 mm L1270969 602<br />
Zinc Selenide 0.1 mm L1270970 1181<br />
Luer-Lok Syringe<br />
for Sealed Liquid Cells<br />
Sealed Cell<br />
Part No.<br />
Each(€)<br />
04967845 11<br />
250
Semi-demountable Cells and Windows<br />
For High-Viscosity Liquids or Mull Samples<br />
By using rectangular windows instead of circular windows,<br />
the demountable cell becomes a semi-demountable cell. The<br />
semi-demountable cell can be used either as a demountable<br />
cell or as a sealed cell for high-viscosity liquids or mull<br />
samples. Combining two different requirements into one<br />
cell allows a myriad of different sampling applications.<br />
For Liquid Samples<br />
After assembling the cell, you<br />
can introduce the liquid sample<br />
through injection ports that<br />
are part of the top plate. The<br />
windows and spacers are not<br />
cemented together, allowing<br />
you to disassemble the cell<br />
easily. The semi-demountable<br />
cell is ideal for samples that<br />
are hard to clean or for<br />
unknown liquids which may<br />
contain moisture and attack<br />
hygroscopic window materials.<br />
For Mull Samples<br />
Liquid cells can also be used if Demountable Cell<br />
your sample is a Nujol mull<br />
or a capillary film, just use two undrilled windows and use<br />
the cell as a straight demountable cell. Select from a wide<br />
variety of window materials to meet your analytical needs.<br />
To order a semi-demountable cell, order the Universal<br />
Demountable Cell and your choice of windows and spacers.<br />
A thickness-compensating spacer is required for 2 mm<br />
thick windows. Alternatively, the complete kit can be<br />
ordered preassembled.<br />
Universal Demountable<br />
Cell Mount<br />
Includes top and back plates.<br />
Semi-demountable Cell Parts<br />
Part No.<br />
Components Part No. Each (€)<br />
1<br />
Back Plate<br />
23 Window Aligner 04821132 12<br />
31 Neoprene TM Gasket L1270512 15<br />
43 Undrilled Window (see product listing at right)<br />
53 Spacer (see product listing at right)<br />
63 Drilled Window (see product listing at right)<br />
73 Top Plate<br />
84 Teflon Plugs (pkg. 6) 04821008 6<br />
92 Quick Release Nut 04821131 14<br />
Sampling Accessories and Supplies<br />
Each (€)<br />
L1270986 299<br />
Liquid Sampling Cells and Supplies<br />
Rectangular Semi-demountable Cell Windows<br />
Rectangular Semi-demountable Cell Windows are available<br />
in a variety of window materials. All windows come in<br />
pairs and measure 41 x 23 mm (H x W).<br />
Window Material Thickness Part No. Each (€)<br />
Sodium Chloride 4 mm L1271191 157<br />
Potassium Bromide 4 mm L1271192 155<br />
Calcium Fluoride 4 mm L1271193 247<br />
Barium Fluoride 4 mm L1271194 741<br />
Cesium Iodide 4 mm L1271195 1655<br />
Zinc Selenide 2 mm L1270765 792<br />
Silver Bromide 2 mm L1270666 1987<br />
Thallium Bromide-Iodide 2 mm L1270664 759<br />
Rectangular Spacers for Rectangular<br />
Semi-demountable Cell Windows<br />
Spacer Material Thickness Qty. Part No. Each (€)<br />
Lead 0.025 mm 10 L1270301 74<br />
Teflon 0.05 mm 6 L1270402 74<br />
Teflon 0.1 mm 6 L1270404 61<br />
Teflon 0.2 mm 3 L1270408 74<br />
Teflon 0.5 mm 3 L1270409 74<br />
Teflon 1 mm 3 L1270410 61<br />
Assorted (2 of each) L1270421 97<br />
Rectangular Semi-demountable<br />
Cell Kits (Preassembled)<br />
Window Material Pathlength Part No. Each (€)<br />
Sodium Chloride 0.025 mm L1270741 278<br />
0.05 mm L1270742 292<br />
0.1 mm L1270744 273<br />
0.2 mm L1270747 273<br />
0.5 mm L1270748 273<br />
1 mm L1270749 273<br />
Potassium Bromide 0.025 mm L1270751 330<br />
0.05 mm L1270752 366<br />
0.1 mm L1270754 312<br />
0.2 mm L1270757 366<br />
0.5 mm L1270758 366<br />
1 mm L1270759 366<br />
Calcium Fluoride 0.025 mm L1270761 500<br />
0.05 mm L1270762 570<br />
0.1 mm L1270764 570<br />
0.2 mm L1270767 500<br />
0.5 mm L1270768 500<br />
1 mm L1270769 570<br />
1 2 3 4 5 6<br />
7<br />
8<br />
9<br />
Sampling Accessories and Supplies Infrared Spectroscopy<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
251
Infrared Spectroscopy Sampling Accessories and Supplies<br />
Sampling Accessories and Supplies<br />
Microscopy Sampling Accessories and Supplies<br />
Beam Condensers<br />
5X Beam Condenser<br />
For Easy Analysis of Microsamples<br />
FT-IR Beam Condenser Part No. 01860794<br />
A beam condenser is required for microsamples such<br />
as KBr microdisks, paint flakes, small spots on polymer<br />
films, and even single fibers when an optional fiber holder<br />
is used. The optical design of the 5X Beam Condenser<br />
provides optimum light-gathering power and ease of use<br />
when working with microsamples. The 5X Beam Condenser<br />
includes the transfer optics and Microsample Disk Holder.<br />
Benefits include:<br />
Easy measurement of microgram and submicrogram<br />
quantities of sample<br />
Highly efficient optical design results in high-quality<br />
FT-IR spectra<br />
Miniature Diamond Anvil Cell available for high-pressure<br />
analysis of small, optically thick polymeric samples<br />
Part No.<br />
Each (€)<br />
01860794 2751<br />
Diamond Anvil Cell<br />
Horizontally Mounted Stage, Holder<br />
for Miniature Diamond Anvil Cell<br />
Microfocus Accessory<br />
The Microfocus Accessory is a low-cost Beam Condenser<br />
for transmission measurement of<br />
small samples such as fibers and<br />
paint flakes.<br />
Part No.<br />
L1160550<br />
Each (€)<br />
616<br />
40-Micron Aperture for<br />
Microfocus Accessory<br />
(pkg. 5)<br />
250-Micron Aperture for<br />
Microfocus Accessory<br />
(pkg. 5)<br />
18-Micronfiber Holder for 5X Beam Condenser<br />
or Microfocus Accessory<br />
(pkg. 5)<br />
33-Micronfiber Holder for 5X Beam Condenser<br />
or Microfocus Accessory<br />
(pkg. 5)<br />
Part No.<br />
Part No.<br />
Part No.<br />
Each (€)<br />
L1160585 137<br />
Part No.<br />
Each (€)<br />
L1160583 197<br />
Each (€)<br />
L1160581 440<br />
Part No.<br />
Each (€)<br />
N9302618 6000<br />
Part No.<br />
Each (€)<br />
01862812 200<br />
Each (€)<br />
L1160582 159<br />
252
Microsampling Tools<br />
PerkinElmer offers a range of carefully selected tools and<br />
<strong>supplies</strong> which allow you to prepare and manipulate<br />
samples for infrared microspectroscopy.<br />
Microsampling Tool Kit<br />
Includes: Dissecting Forceps (N9302610), Roller Knife<br />
(N9302619), Micro Specimen Tweezers (N9302609),<br />
Tungsten Microneedle (N9302604), Straight Micro Probe<br />
(N9302605), Aluminum Probe Handle<br />
(N9302622), and Pin Vise (N9302603). Part No. Each (€)<br />
Dissecting Forceps<br />
Cadmium-plated, sharp<br />
points 4 in. long, serrated tip.<br />
Roller Knife<br />
Consists of razor knife at one end and a roller-wheel device<br />
for pressing samples at the other end. Use for cutting and<br />
sectioning specimens and for<br />
flattening samples such as fibers,<br />
hairs, and crystals.<br />
Part No.<br />
N9302619<br />
Each (€)<br />
77<br />
Tweezers<br />
Description Part No. Each (€)<br />
Very sharp points, excellent for N9302609 77<br />
miniature and micro specimens<br />
Non-magnetic, stainless steel points N9302607 63<br />
are 0.055" wide, rounded tips<br />
Narrow needle points, indented shanks N9302608 71<br />
Tungsten Microneedle<br />
Tungsten alloy, 0.0002 in. tip.<br />
Straight Micro Probe<br />
Stainless steel, very sharp.<br />
Angled Micro Probe<br />
Stainless steel, very sharp, 90° bend.<br />
Aluminum Probe Handle<br />
For screw-based probes. At least<br />
one handle must be ordered.<br />
Pin Vise<br />
Use for specimen preparation to separate fibres and films.<br />
Range 0 - 1 mm. (Holds tungsten wires that are sharpened<br />
to a fine point by placing them<br />
in a burner flame and then<br />
in sodium nitrate).<br />
Part No.<br />
N9302603<br />
Each (€)<br />
22<br />
Sampling Accessories and Supplies<br />
N1870151 293<br />
Part No.<br />
Microscopy Sampling Accessories and Supplies<br />
Each (€)<br />
N9302610 15<br />
Part No.<br />
Each (€)<br />
N9302604 56<br />
Part No.<br />
Each (€)<br />
N9302605 56<br />
Part No.<br />
Each (€)<br />
N9302606 56<br />
Part No.<br />
Each(€)<br />
N9302622 22<br />
Rotatable Cell Holder and<br />
Microscope Supplies<br />
Rotatable Cell Holder<br />
Requires, but does not include,<br />
Rotatable Cell Holder Plate.<br />
Rotatable Cell Holder Plate<br />
Sample Holder<br />
3 x 13 mm.<br />
Sample Holder with Gold Mirror<br />
Spare Germanium Crystal<br />
with Holder<br />
For ATR Objective.<br />
Spare Silicon Crystal with Holder<br />
For ATR Objective.<br />
Base Microscope Slides<br />
Box of 72, 1 x 3 in., 1 mm thick, optical<br />
quality glass, for visible observations.<br />
Infrared Windows<br />
Part No.<br />
Each (€)<br />
L1861790 43<br />
Part No.<br />
Each (€)<br />
L1861789 48<br />
Part No.<br />
Each (€)<br />
L1861634 32<br />
Part No.<br />
Each (€)<br />
L1860409 119<br />
Part No.<br />
Each (€)<br />
L1860268 1555<br />
Part No.<br />
Each (€)<br />
L1860269 2081<br />
Part No.<br />
Each (€)<br />
N9302600 23<br />
Infrared windows allow you to support microsamples<br />
for infrared analysis with the microscope. All windows are<br />
13 mm diameter and are available in the Infrared crystals<br />
designated below.<br />
Window Material Dimensions Part No. Each (€)<br />
Barium Fluoride 13 x 1 mm N9302611 196<br />
Barium Fluoride 13 x 2 mm N9302612 182<br />
Zinc Selenide 13 x 1 mm N9302613 223<br />
Sodium Chloride 13 x 2 mm N9302614 32<br />
Potassium Bromide 13 x 2 mm N9302615 43<br />
Sampling Accessories and Supplies Infrared Spectroscopy<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
253
Infrared Spectroscopy Sampling Accessories and Supplies<br />
Sampling Accessories and Supplies<br />
Microscopy Sampling Accessories and Supplies<br />
Sampling Accessories<br />
FT-IR Microscope Sampling Accessory Kit<br />
Includes two KBr windows (13 x 2 mm), Rotatable Sample<br />
Disk Holder, two 3 x 1 in. three-position sample holders with<br />
13 mm apertures (one position with a fixed gold-coated glass<br />
mirror), sample spacer for large samples, view-through<br />
variable apertures set, 100-micron pin hole aperture,<br />
low-magnification screen, and sample accessory<br />
carrying case. Supplied as standard<br />
with AutoIMAGE TM Systems.<br />
Part No. Each (€)<br />
Whole Field Aperture Kit*<br />
Rotatable Cell Holder<br />
Rotatable Cell Holder Plate<br />
Holder for Reflection<br />
Transmission Measurements*<br />
* Included in FT-IR Microscope Sampling Accessory Kit (L1860250).<br />
Hot Stage Accessory<br />
L1860250 1579<br />
Simplifies the isolation of the sample areas for Infrared<br />
examination by allowing the sample to be kept in view,<br />
even when an aperture is in place.<br />
Part No. Each (€)<br />
L1860249 574<br />
Part No.<br />
Part No.<br />
Each (€)<br />
L1861790 43<br />
Part No.<br />
Each (€)<br />
L1861789 48<br />
Each (€)<br />
N1873124 67<br />
Consists of a heating block, which accepts FT-IR windows<br />
and a temperature controller. The heating block contains<br />
an integral thermocouple; the temperature is digitally<br />
displayed in degrees Centigrade on the controller. The Hot<br />
Stage can heat samples up to 230 °C in 1° increments. A<br />
target temperature may be selected and maintained. The<br />
Hot Stage is held in the slide clip on the sample stage of a<br />
PerkinElmer FT-IR Microscope. The microscope requires<br />
no modifications to accept the Hot Stage Accessory.<br />
Power Requirement Part No. Each (€)<br />
100/120 V, 60 Hz N1870184 6600<br />
220/240 V, 50 Hz N1870188 6800<br />
AutoIMAGE<br />
Compression Cell<br />
This is a device for flattening soft materials and holding<br />
specimens flat and in optical contact with salt windows.<br />
The cell consists of an aluminum block machined to<br />
accept FT-IR windows, window retainers, and a special<br />
wrench to apply pressure across the IR windows. The<br />
specimen is held between two FT-IR windows. The<br />
Compression Cell fits into the sample slide holder on the<br />
stage of the FT-IR microscope. One- and two-millimeter<br />
thick windows of 13 mm outer diameter can be used with<br />
the cell; two KBr windows (2 mm thickness) are included.<br />
The cell can apply pressure without rotating (and therefore<br />
scratching) the windows. Fits both MultiScope TM<br />
and AutoIMAGE systems.<br />
Part No. Each (€)<br />
N1870185 760<br />
254
Diffuse Reflectance Accessories<br />
Ideal for Measurement of Opaque or Highly Scattering Samples<br />
Diffuse Reflectance Accessory provides a convenient and<br />
sensitive method for analyzing opaque or highly scattering<br />
solid samples such as pharmaceuticals, food products, soap<br />
powders, coal, clay, paper, painted surfaces, polymer foam,<br />
and catalysts.<br />
Fast, reproducible measurement; no alignment<br />
Flexibility for different sample holders to accommodate<br />
macro- and microsampling<br />
cups, silicon carbide<br />
abrasive pads, and<br />
diamond abrasive<br />
sampling sticks<br />
No sample preparation<br />
using unique abrasive<br />
pads and sticks<br />
Robust design with<br />
enclosed optics<br />
Macrosample Cup<br />
Description Qty. Part No. Each (€)<br />
For Spectrum One/100 1 L1201654 74<br />
For Pre-Spectrum One 1 L1271012 14<br />
Microsample Cup<br />
Description Qty. Part No. Each (€)<br />
For Spectrum One/100 1 L1201655 74<br />
For Pre-Spectrum One 1 L1271013 14<br />
Abrasive Pad<br />
Description Qty. Part No. Each (€)<br />
Metal-Coated Silicon Carbide 100 L1275106 299<br />
Uncoated Silicon Carbide 100 L1271021 110<br />
Abrasive Sampling Stick<br />
Description Qty. Part No. Each (€)<br />
Metal-Coated Diamond 100 L1275105 484<br />
Uncoated Diamond 100 L1275102 407<br />
Multi-Purpose Sample Holder<br />
Diffuse Adapter Kit<br />
For 2000 or GX to Spectrum One/100.<br />
Part No.<br />
Sampling Accessories and Supplies<br />
Diffuse Reflectance Accessory<br />
Each (€)<br />
L1201865 138<br />
Part No.<br />
Each (€)<br />
L1200394 185<br />
Horizontal Attenuated Total<br />
Reflectance (HATR) Accessories<br />
Reflectance Accessories<br />
A Fast, Reliable Means for Analyzing a Wide Variety of Samples<br />
Based on an attenuated total reflectance principle, the<br />
PerkinElmer Horizontal ATR (HATR) Accessory offers a<br />
fast, reliable means for analyzing a wide range of solid,<br />
liquid, and paste samples not easily examined by<br />
conventional transmission techniques.<br />
HATR Top Plates for Spectrum One/100<br />
Plate Material Angle Plate Type Part No. Each (€)<br />
ZnSe 45° Flat L1200313 730<br />
45° Trough L1200314 730<br />
60° Flat L1200315 730<br />
60° Trough L1200316 730<br />
Coated ZnSe* 45° Flat L1200323 1232<br />
45° Trough L1200324 1232<br />
60° Flat L1200325 1232<br />
Ge 30° Flat L1200337 891<br />
30° Trough L1200338 891<br />
45° Flat L1200333 891<br />
45° Trough L1200334 891<br />
60° Flat L1200335 891<br />
60° Trough L1200336 891<br />
AMTIR 45° Flat L1200343 1148<br />
45° Trough L1200344 1148<br />
60° Flat L1200345 1148<br />
60° Trough L1200346 1148<br />
* Includes special protective coating on the crystal for extended lifetime.<br />
HATR Top Plates for Pre-Spectrum One<br />
Plate Material Plate Type Part No. Each (€)<br />
ZnSe Flat L1360267 628<br />
Trough L1360266 628<br />
Ge Flat L1360269 837<br />
Trough L1360268 837<br />
AMTIR Flat L1360271 837<br />
Trough L1360270 837<br />
KRS-5 Flat L1360273 837<br />
Trough L1360272 837<br />
HATR Accessory<br />
Sampling Accessories and Supplies Infrared Spectroscopy<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
255
Infrared Spectroscopy Sampling Accessories and Supplies<br />
Sampling Accessories and Supplies<br />
Reflectance Accessories<br />
Pressure Arm Kit<br />
for the Spectrum One<br />
HATR Adapter Kit<br />
Description Part No. Each (€)<br />
2000 to 1000 or GX to either RX or BX L1360274 150<br />
2000 or GX to Spectrum One/100 L1200393 185<br />
HATR Variable Pressure<br />
Clamp Assembly<br />
FT-NIR Reflectance Accessories<br />
FT-NIRA Solids Rotating Sample Holder<br />
Provides improved repeatability for reflectance measurements<br />
of coarse, granular materials. Requires, but does not include,<br />
Spectrum One NTS/100N FT-NIRA (L1240050).<br />
Set of Five Spare Glass Sample Dishes for FT-NIRA<br />
Solids Rotating Sample Holder<br />
High-Performance Sample Dish<br />
for FT-NIRA Solids Rotating Sample Holder<br />
Comprises high-quality Suprasil base.<br />
Sample Cup for the Spectrum<br />
IdentiCheck Reflectance Accessory<br />
Description Qty. Part No. Each (€)<br />
Upper Position 3 L1181318 1507<br />
Lower Position 4 L1181319 329<br />
FT-NIRA Transflectance Liquids<br />
Sampling Accessory Starter Kit<br />
Includes five Liquids Reflectors<br />
and Petri dish bases, FT-NIRA Liquids<br />
Sampling procedure, and user guide.<br />
FT-NIRA Transflectance Liquids<br />
Sampling Accessory Kit<br />
Includes 100 FT-NIRA Liquids<br />
Reflectors and Petri dish bases.<br />
Part No.<br />
Each (€)<br />
L1200321 592<br />
Part No.<br />
Each (€)<br />
L1360275 281<br />
Part No.<br />
Each (€)<br />
L1240053 1016<br />
Part No.<br />
Each (€)<br />
L1181257 110<br />
Part No.<br />
Each (€)<br />
L1185305 281<br />
Part No.<br />
Each (€)<br />
L1185153 99<br />
Part No.<br />
Each (€)<br />
L1180501 865<br />
FT-NIRA Liquids Petri Dish Base<br />
(pkg. 100)<br />
FT-NIRA Liquids Reflector<br />
(pkg. 100)<br />
Disposable Glass Vials for FT-NIRA<br />
4 mL glass vials with cap, (pkg. 100).<br />
Specular Reflectance Accessories<br />
Variable-Angle Specular Reflectance Accessory<br />
Flat Reference Mirror<br />
Aperture Mask<br />
For Measurement of Samples<br />
with Glossy Coatings and<br />
Reflective Surfaces<br />
PerkinElmer offers both Fixedangle<br />
and Variable-angle Specular<br />
Reflectance Accessories. Optimized<br />
to match the throughputs of all<br />
PerkinElmer FT-IR spectrometers,<br />
these accessories provide<br />
unmatched ease of use and<br />
optical efficiency.<br />
Replacement Reference<br />
Mirrors and Aperture<br />
Masks are available<br />
separately. Aperture<br />
Masks are available<br />
in 3 sizes for<br />
studying a variety<br />
of small sample areas.<br />
Aperture Part No. Each (€)<br />
2 mm 01861854 35<br />
5 mm 01861861 35<br />
10 mm 01861862 35<br />
Universal Attenuated Total<br />
Reflectance (ATR) Accessories<br />
Spectrum One Universal ATR Optional/<br />
Replacement Top-Plate<br />
Part No.<br />
Each (€)<br />
L1180502 386<br />
Part No.<br />
Each (€)<br />
L1180503 602<br />
Part No.<br />
Each (€)<br />
L9001029 78<br />
Part No.<br />
Each (€)<br />
00071006 119<br />
Description Part No. Each (€)<br />
1 Reflection Top-Plate L1200364 4306<br />
3 Reflection Top-Plate L1200365 4306<br />
9 Reflection Top-Plate L1200366 4306<br />
Pressure Arm Kit L1200321 592<br />
256
Liquid and Mull FT-IR Sampling Kit Part No. L1365311<br />
FT-IR Sampling Kits<br />
Two FT-IR Sampling Kits are available to help the newcomer<br />
to FT-IR spectroscopy choose the more frequently required<br />
items, and to simplify ordering and storage. KBr has been<br />
chosen for the transmitting material. The two kits are<br />
packaged in attractive storage and carrying cases.<br />
Liquid and Mull FT-IR Sampling Kit<br />
This kit will satisfy the needs of most new users of FT-IR<br />
spectroscopy and has been designed to provide all the<br />
necessary equipment for handling liquids and mulls. A<br />
magnetic film holder is also included.<br />
Includes:<br />
Polystyrene Film (0.038 mm)<br />
Nujol DD 057 (100 mL)<br />
10 cm Micro Spatula<br />
2 mL Luer Syringe<br />
Agate Pestle and Mortar<br />
Magnetic Film Holder – Circular<br />
Universal Demountable Cell Mount<br />
Assorted Spacers<br />
KBr Demountable Cell Windows (two pairs)<br />
KBr Semi-demountable Cell Windows (two pairs)<br />
Part No.<br />
Sampling Accessories and Supplies<br />
Each (€)<br />
L1365311 2117<br />
General Purpose FT-IR Sampling Kit<br />
Sampling Kits and Supplies<br />
General Purpose FT-IR Sampling Kit Part No. L1365312<br />
This kit includes all of the necessary equipment for handling<br />
liquids, mulls, and KBr pellets and also includes a magnetic<br />
film holder and a Microfocus Accessory. It should be noted<br />
that a laboratory press for making KBr pellets should be<br />
ordered separately.<br />
Includes:<br />
Polystyrene Film (0.038 mm)<br />
Universal KBr Disk Holder<br />
Nujol DD 057 (100 mL)<br />
10 cm Micro Spatula<br />
2 mL Luer Syringe<br />
Agate Pestle and Mortar<br />
Magnetic Film Holder – Circular<br />
KBr Powder (100 g)<br />
13 mm KBr Die<br />
Micro-disk Holder Accessory<br />
Beam Condenser Accessory<br />
100 μm Diameter Sample Holder Accessory<br />
500 μm Diameter Sample Holder Accessory<br />
Universal Demountable Cell Mount<br />
Assorted Spacers<br />
KBr Demountable Cell Windows (two pairs)<br />
KBr Semi-demountable Cell Windows (two pairs)<br />
FT-IR Sampling Kit Supplies<br />
Part No.<br />
Each (€)<br />
L1365312 3242<br />
Description Size Part No. Each (€)<br />
Nujol 100 mL 04960691 58<br />
Fluorolube TM 1 oz bottle 01862301 41<br />
KBr Powder 100 g 04977043 131<br />
KBr Random Cuttings 100 g bottle N9300086 103<br />
Micro Spatula 10 cm 04967843 11<br />
Luer Syringe 2 mL 04967845 11<br />
Agate Pestle and Mortar 04967854 91<br />
Sampling Accessories and Supplies Infrared Spectroscopy<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
257
Infrared Spectroscopy Sampling Accessories and Supplies<br />
Sampling Accessories and Supplies<br />
Solid Sampling Accessories and Supplies<br />
There are several options to consider when analyzing<br />
solid samples. Depending on the chemical composition<br />
and spectral information needed you can select any of<br />
the following techniques:<br />
Prepare a potassium bromide pellet<br />
Formulate a sample mull<br />
Measure directly with a diffuse reflectance accessory<br />
Hydraulic Press and Evacuable<br />
Potassium Bromide Die<br />
The KBr pellet technique is probably the one most often<br />
used to prepare solid samples for infrared analysis. First the<br />
sample is ground to a fine particle size and then mixed<br />
uniformly with dry KBr powder. Finally, this sample is<br />
placed in an evacuable KBr die and a 13 mm clear disk is<br />
pressed in a hydraulic press to form a KBr pellet. Pellets can<br />
also be prepared using less expensive and quicker methods.<br />
Manual Hydraulic Press<br />
Manual Hydraulic Press<br />
This compact and easy-to-operate press is used with the<br />
KBr die to prepare KBr pellets.<br />
The pressure is produced by<br />
operating a pump lever.<br />
Part No.<br />
51004599<br />
Each (€)<br />
3430<br />
Water-Cooled Heated Platens<br />
with Automatic Temperature Control (300 °C)<br />
Model Power Req. Part No. Each (€)<br />
Specac 110 V, 60 Hz 04978444 4421<br />
220 V, 50 Hz 04978443 4421<br />
PerkinElmer 110 V, 60 Hz L1270504 2261<br />
220 V, 50 Hz L1270503 2261<br />
Evacuable Potassium Bromide Die<br />
The Evacuable Potassium Bromide Die will<br />
prepare 13 mm diameter pellets of the highest<br />
quality and clarity. The pellet is formed inside<br />
an evacuated chamber and pressed between a<br />
highly polished anvil and plunger. This die is<br />
precisely constructed to produce pellets<br />
of uniform quality and will continue<br />
to provide many years of service in<br />
your laboratory.<br />
Part No. Each (€)<br />
Evacuable Potassium Bromide Die Accessories<br />
The following parts are included with the Evacuable<br />
Potassium Bromide Die, but can also be ordered separately:<br />
Description Part No. Each (€)<br />
Plunger 51001152 170<br />
Set of Upper and Lower Anvils 04820519 195<br />
Set of O-Rings 04800514 150<br />
Perspex TM Extractor Ring 04977042 50<br />
Potassium Bromide Pellet Holder<br />
A KBr Pellet Holder is required,<br />
but must be ordered separately.<br />
Adjustable Adapter<br />
The Adjustable Adapter is required in order to mount<br />
the Potassium Bromide Pellet Holder<br />
in your FT-IR spectrometer.<br />
Part No. Each (€)<br />
L1060351 46<br />
Constant Thickness Film Maker<br />
A constant thickness film maker is available as an option<br />
for this press. When used in conjunction with heated<br />
platens and a press, it enables quick preparation of polymer<br />
film samples for qualitative and<br />
quantitative analysis.<br />
Part No. Each (€)<br />
Support Rings For KBr Pellets<br />
51001144 478<br />
Part No.<br />
Each (€)<br />
04810949 142<br />
04977032 2572<br />
Circular paper rings to reinforce your KBr disks are available.<br />
If the amount of sample is limited there are also paper<br />
microframes which reduce the size of the pellet to 11 x 2 mm.<br />
Description Qty. Part No. Each (€)<br />
Paper Rings 100 51001148 170<br />
Microframes 100 51001149 114<br />
258
KBr Pellet Mini-press<br />
The Mini-press is designed for those situations where you<br />
occasionally need to make KBr pellets. This is the simplest<br />
solid sample device and is ideal for student use, where very<br />
low cost is an important factor. Two highly polished bolts<br />
turn against each other in a steel cylinder. The pellet is<br />
formed right inside the cylinder which becomes the sample<br />
holder. Once formed, the pellet cannot be removed from the<br />
cylinder without being destroyed. The Mini-press requires<br />
but does not include the holder.<br />
Evacuable KBr Mini-press<br />
Holder for Evacuable<br />
KBr Mini-press<br />
KBr Pellet Quick Press<br />
The Quick Press provides a fast and economical way to<br />
prepare good quality KBr pellets. A hydraulic press is not<br />
needed and pellets with diameters of 1, 3, or 7 mm can be<br />
prepared, depending on the die sets used. The Quick Press<br />
is simple and easy to use. Simply load the sample and<br />
potassium bromide mixture into the selected die. Place the die<br />
in position in the Quick Press. Then apply a steady pressure<br />
to the handle, equivalent to that of a firm handshake.<br />
Quick Press<br />
Quick Press<br />
Part No.<br />
The Quick Press consists of a handpress, a 7 mm die set,<br />
and a metal collar.<br />
Part No. Each (€)<br />
Sampling Accessories and Supplies<br />
Each (€)<br />
51002592 211<br />
Part No.<br />
Each (€)<br />
51002593 84<br />
01860436 1145<br />
Solid Sampling Accessories and Supplies<br />
Die Sets for Micropellets<br />
Micropellets can be prepared in the Quick Press by<br />
purchasing the optional 3 or 1 mm die. The KBr pellet is<br />
formed in a metal collar that fits into an adjustable Pellet<br />
Holder. The 1 mm micro-KBr pellets can be used in the<br />
PerkinElmer 5X Beam Condenser Accessory.<br />
Die Size Part No. Each (€)<br />
1 mm 01862295 355<br />
3 mm 01862292 343<br />
7 mm 01862289 305<br />
Adjustable Pellet Holder Adapter<br />
Required, but not included,<br />
with Quick Press.<br />
Polarizers<br />
Polarized radiation is used to study orientation effects<br />
in single crystals, polymers, and other large molecules.<br />
Polarization measurements are also used to determine<br />
optical constants and to assist in the assignment of<br />
observed absorption bands to normal modes of vibration.<br />
The Spectrum GX, Spectrum 2000, and System 2000 FT-IR<br />
spectrometers can have software controlled polarizers<br />
installed inside the instrument, but other PerkinElmer<br />
infrared instruments will require a polarizer, mounted<br />
in the sample compartment.<br />
Polarizer Kits<br />
Description Part No. Each (€)<br />
Mid-IR, Thallium Bromide-Iodide L1271025 3218<br />
Far-IR, Polyethylene L1271026 2309<br />
Near-IR, Calcium Fluoride L1271027 2966<br />
Visible Polarizer Kit<br />
Useful for the study of crystalline materials, most of which<br />
exhibit bi-refringence (i.e. double refraction). Areas of<br />
disparate chemical composition can be differentiated<br />
by observation under crossed polarizers (i.e. a fiber in<br />
a polymer, gel imperfections in polymer film, different<br />
layers in a laminated structure). Fits both MultiScope<br />
and AutoIMAGE systems.<br />
Part No. Each (€)<br />
Infrared Polarizer Kit<br />
Part No.<br />
Each (€)<br />
L1060351 46<br />
L1860221 1639<br />
Used to study orientation effects of single crystals,<br />
polymers and other large molecules. Fits both MultiScope<br />
and AutoIMAGE systems.<br />
Part No. Each (€)<br />
L1860408 3648<br />
Sampling Accessories and Supplies Infrared Spectroscopy<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
259
Infrared Spectroscopy Sampling Accessories and Supplies<br />
Sampling Accessories and Supplies<br />
Solid Sampling Accessories and Supplies<br />
FT-NIR Remote Immersion Probe Part No. L1181314<br />
Remote Sampling System Accessories<br />
Remote Solids Probe Kit<br />
Featuring probe and connecting fibers.<br />
Only for use with the Spectrum<br />
One NTS/100N.<br />
Replacement Remote Solids Fiber Cable<br />
For use with the High-Performance<br />
Remote Solids Sampling System.<br />
Spare Solids Probe Reflectance Cap<br />
For use with the High-Performance<br />
Remote Solids Sampling System.<br />
FT-NIR Remote Immersion Probe<br />
Pathlength Part No. Each (€)<br />
10 mm L1181314 9900<br />
1 mm L1181316 9900<br />
Sample Holders and Film Mounts<br />
A variety of sample holders and film mounts are available to<br />
accommodate polymer films and other thin samples<br />
Magnetic Film Holder<br />
Use the Magnetic Film Holder to hold polymer films<br />
and a wide variety of other thin samples by placing them<br />
between the ring-shaped magnet and<br />
the backplate.<br />
Part No. Each (€)<br />
Spring-Loaded Sample Holder<br />
This sample holder consists of a clamping plate held by<br />
light spring tension. Use it to hold single windows, films,<br />
filters, or films mounted on cards.<br />
Part No. Each (€)<br />
Adhesive Film Mounts<br />
Part No.<br />
Each (€)<br />
L1240062 15000<br />
Part No.<br />
Each (€)<br />
L9001162 4876<br />
Part No.<br />
Each (€)<br />
L1245221 97<br />
04974438 82<br />
01860470 66<br />
These convenient, easy-to-use, and economical cardboard<br />
mounts permanently hold polymer films or other thin<br />
samples. Just place the film over the aperture and fold<br />
the adhesive sides together to form a permanent mount.<br />
The mounts fit directly into the<br />
sample slide of the spectrometer. Part No. Each (€)<br />
(pkg. 100)<br />
01860449 148<br />
260
Software<br />
Spectrum Infrared Software<br />
Application Software Packages<br />
Spectrum Search Plus Software<br />
Provides a library search and match capability with five<br />
different algorithms, and an expert system for spectral<br />
interpretation, resulting in a chemical functional group<br />
listing of the possible structural units (PSUs) displayed on<br />
the screen. In addition, Spectrum Search can perform<br />
interactive interpretation. The program includes provision<br />
for the entry of chemical and physical data about the sample,<br />
which can be used to eliminate obvious mismatches. The<br />
output includes the 28 closest matches from a single library<br />
or any group of libraries. The Fluka library (1725 spectra), an<br />
ATR Polymer library (100 spectra), a Raman Polymer library<br />
(100 spectra), and a Small Drugs library are included as<br />
standard. Spectrum Search Plus can be used in conjunction<br />
with the complete Sadtler collection of libraries. The software<br />
provides full builder graphics and multiple spectra split<br />
display. Included is a license certificate<br />
to access Spectrum Search Plus, which<br />
Part No. Each (€)<br />
resides on the Spectrum Software CD. L1108755 1876<br />
IR Expert Software<br />
Allows indication of spectrum quality and common<br />
measurement problems, causes and cures. Also included<br />
is automatic data optimization according to user-defined<br />
parameters. Included is a license certificate to access IR<br />
Expert, which resides on the Spectrum Software CD. Only<br />
available for Spectrum One systems.<br />
Part No. Each (€)<br />
Spectrum QUANT+<br />
This package is a multicomponent quantitative analysis<br />
package based on principal component regression (PCR).<br />
A complete set of diagnostics is available in graphical<br />
presentations to ensure proper calibration in easy-tounderstand<br />
formats. The statistical approach used by<br />
Spectrum QUANT+ enables it to ignore errors caused<br />
by uncontrolled variations from sample to sample, and<br />
minimize errors caused by sampling methods. In addition<br />
to measuring concentrations, Spectrum QUANT+ can relate<br />
spectral data to physical properties of the sample being<br />
analyzed. Up to 15 properties may be determined and up<br />
to 150 standards may be used in the calibration set.<br />
Included is a license certificate to<br />
Part No. Each (€)<br />
access Spectrum QUANT+, which<br />
resides on the Spectrum Software CD. L1108757 3095<br />
QUANT+ Upgrade<br />
L1108759 610<br />
Single-user upgrade for Spectrum QUANT+. Includes<br />
IR Spectroscopy CD, manual, and license certificate for<br />
Spectrum QUANT+.<br />
Part No. Each (€)<br />
L1108822 1117<br />
Spectrum QUANTC Software<br />
This package is designed for the quantitative analysis of<br />
mixtures using a least-squares curve-fitting algorithm to<br />
determine the concentration of up to 15 components from<br />
a single spectrum. Methods can be password protected<br />
and include a history file, which details the changes made<br />
during development. The software also includes method<br />
validation, trend analysis, component correlation spectra,<br />
and context-sensitive help. Included is a license certificate<br />
to access Spectrum QUANTC, which resides on the<br />
Spectrum Software CD.<br />
Part No. Each (€)<br />
QUANTC Upgrade<br />
Spectrum Procedures<br />
This is a FT-IR macro-programming package, which<br />
requires no programming or syntax checking. All the major<br />
elements of FT-IR analytical procedures, such as data<br />
collection, reports, labels, and push buttons, are available<br />
as modules that are combined like building blocks to create<br />
the procedure. Search, Spectrum QUANT+ and Spectrum<br />
QUANTC analysis can be used in the procedure. Once<br />
developed, procedures can be compiled as executable files<br />
and distributed as stand-alone applications or called from<br />
the Spectrum Software. Included is a license certificate to<br />
access Spectrum Procedures, which resides on the<br />
Spectrum Software CD. Requires,<br />
Part No. Each (€)<br />
but does not include, Microsoft<br />
Visual Basic v4.0 (16 bit), (L1108772). L1108760 1876<br />
Spectrum Procedures Upgrade<br />
Single-user upgrade for Spectrum Procedures. Includes<br />
FT-IR Spectroscopy CD, manual, and license certificate for<br />
Spectrum Procedures.<br />
Part No. Each (€)<br />
Visual Basic Kit v4.0<br />
L1108758 1876<br />
Single-user upgrade for Spectrum QUANTC. Includes<br />
IR Spectroscopy CD, manual, and license certificate for<br />
Spectrum QUANTC.<br />
Part No. Each (€)<br />
L1108824 657<br />
L1108823 657<br />
Required for Spectrum Procedures. Includes license and<br />
software for Microsoft Visual Basic v6.0 and downgrade<br />
CD to allow Microsoft Visual Basic<br />
v4.0 (16-bit) to be installed.<br />
Part No. Each (€)<br />
L1108772 1762<br />
Software Infrared Spectroscopy<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
261
Software<br />
Spectrum Infrared Software<br />
Infrared Spectroscopy Software<br />
Spectrum Procedures and Visual Basic Kit<br />
Includes Spectrum Procedures (L1108760)<br />
and Visual Basic (L1108772).<br />
PerkinElmer Educational Software Package<br />
Provide schools and colleges with software to advance<br />
students, understanding of FT-IR. IR-Tutor software guides<br />
students through the background and theory of FT-IR<br />
spectroscopy as well as how to interpret the spectra they<br />
collect. Spectrum software allows students to perform<br />
advanced processing on spectra, create professional<br />
reports, and use automatic spectral interpretation and<br />
comparison algorithms. Only available with order<br />
of a Spectrum BX or RX instrument.<br />
Includes:<br />
IR-Tutor software disks<br />
Spectrum Software CD and manual<br />
10-user license for IR-Tutor<br />
10-user license for Spectrum Software<br />
AutoIMAGE Upgrades<br />
AutoIMAGE Upgrade Kit<br />
Part No.<br />
Part No.<br />
Single-user license for AutoIMAGE v4.0 or earlier to<br />
AutoIMAGE v5.0 upgrade. Includes AutoIMAGE v5.0<br />
software and AutoIMAGE manuals. Requires, but does<br />
not include, AutoIMAGE Frame Grabber Card Upgrade<br />
Kit (L1860305).<br />
Specifications:<br />
AutoIMAGE v5.0 operates under the Windows 2000<br />
(service pack 2-4) and Windows XP Pro SP2 operating<br />
systems only<br />
Spectrum BX, 1000, and RX instruments cannot be upgraded<br />
to the latest AutoIMAGE v5.0 software<br />
Spectrum v5.0 is required to run AutoIMAGE v5.0<br />
AutoIMAGE v5.0 does not meet the technical requirements<br />
of 21 CFR Part 11 and therefore must not be installed onto<br />
systems with Spectrum ES v5.0 loaded<br />
AutoIMAGE Frame Grabber Card Upgrade Kit<br />
Each (€)<br />
L1108818 2338<br />
Each (€)<br />
L1108548 1314<br />
Part No.<br />
Each (€)<br />
LX108640 657<br />
This kit upgrades the AutoIMAGE frame grabber to allow<br />
the AutoIMAGE to be controlled by the latest AutoIMAGE<br />
v5.0 software running under Windows 2000. Includes the<br />
Mutech frame grabber card and a<br />
cable adapter to allow the AutoIMAGE<br />
to be connected to the PC.<br />
Part No.<br />
L1860305<br />
Each (€)<br />
2010<br />
PerkinElmer Stage Control Box<br />
This kit is required to upgrade from a Marzhauser stage<br />
controller to a PerkinElmer stage controller to achieve<br />
compatibility with AutoIMAGE v5.0 software. Includes<br />
stage control box, control cable,<br />
and installation instructions.<br />
Part No. Each (€)<br />
Spectrum One/100 AssureID<br />
Upgrades and Validation Suite<br />
Spectrum AssureID is a software suite providing a<br />
dedicated software solution for regulated industries.<br />
Using the latest database technology, data storage is<br />
secure, archival simple, and data retrieval quick.<br />
1. Spectrum AssureID addresses the need of manufacturing<br />
industries to improve product quality, realize efficiencies<br />
and meet the demands of regulatory bodies. It addresses<br />
the need to:<br />
Verify the identity and quality of raw materials, packaging<br />
materials, in-process materials, and finished products<br />
Monitor process variation<br />
Determine accurate concentration of active ingredients,<br />
excipients, additives, and moisture<br />
2. Spectrum AssureID addresses the needs of the QA/QC<br />
market by directly addressing the biggest issues:<br />
Faster than conventional technology allows more testing<br />
leading to better quality<br />
Deployed at the point of manufacture to maximize<br />
turnaround time and reduce cost of poor quality<br />
Simple enough to be used by process operatives<br />
Easy to develop, validate, and implement robust methods<br />
Complete set of compliance tools including intrinsic<br />
21 CFR Part 11 compliance<br />
AssureID operates with Spectrum One/100 MIR and<br />
Spectrum One/100 FT-NIR spectrometers and a whole<br />
host of plug and play accessories including Tablet<br />
Autosampler, FT-NIRA, UATR, HATR, etc.<br />
License to Upgrade Spectrum, Spectrum CFR<br />
or Spectrum ES to Spectrum AssureID v4.0<br />
License to Upgrade Spectrum AssureID v3.0<br />
or earlier to Spectrum AssureID v4.0<br />
L1860279 3260<br />
Part No.<br />
Part No.<br />
Each (€)<br />
LX100689 9400<br />
Each (€)<br />
LX100690 3128<br />
262
Software<br />
Spectrum Infrared Software<br />
Spectrum One Software Upgrades<br />
Spectrum One v6.0 Software Upgrade<br />
License to upgrade Spectrum v3.02 or earlier to Spectrum<br />
One v6.0. Includes Spectrum One v6.0 software, instrument<br />
control, data processing tools, spectral calculator, quantitative<br />
predictions, Spectrum Search, and Report Builder.<br />
5-user and 10-user licenses are available to enable customers<br />
who have already purchased a single-user license to install<br />
the software on additional systems. Instrument manuals are<br />
also included. Upgrade includes Spectrum, IR Expert, and<br />
Spectrum Search only. If upgrades to other software packages<br />
are required these must be ordered separately. Purchase of<br />
single-user license upgrade (LX108848) is a pre-requisite for<br />
purchase of 5-user and 10-user licenses.<br />
License Qty. Part No. Each (€)<br />
Single-user LX108848 788<br />
5-user LX100846 1970<br />
10-user LX100849 3153<br />
Spectrum One NTS v6.0 Software Upgrade<br />
License to upgrade Spectrum v3.02 or earlier to Spectrum<br />
One NTS v6.0. Includes Spectrum One NTS v6.0 software,<br />
instrument control, data processing tools, spectral calculator,<br />
and quantitative predictions, Quant+, QuantC, SIMCA, and<br />
Report Builder. 5-user and 10-user licenses are available to<br />
enable customers who have already purchased a single-user<br />
license to install the software on additional systems.<br />
Spectrum One NTS manuals are also included. Purchase<br />
of single-user license upgrade (LX108848) is a pre-requisite<br />
for purchase of 5-user and 10-user licenses.<br />
License Qty. Part No. Each (€)<br />
Single-user LX108848 788<br />
5-user LX100846 1970<br />
10-user LX100849 3153<br />
Spectrum GX v5.0 Upgrade<br />
Single-user license for Spectrum v3.02 or earlier to Spectrum<br />
GX v5.0 upgrade. Includes Spectrum GX v5.0 software,<br />
instrument control, data processing tools, spectral calculator,<br />
quantitative predictions, Spectrum Search, and Report<br />
Builder. Spectrum GX manuals are also included. Upgrade<br />
includes Spectrum and Spectrum Search only. If upgrades<br />
to other software packages are required these must be<br />
ordered separately.<br />
Part No. Each (€)<br />
L1100980 788<br />
Spectrum BX v5.0 Upgrade<br />
Single-user license for Spectrum v3.02 or earlier to Spectrum<br />
BX v5.0 upgrade. Includes Spectrum BX v5.0 software,<br />
instrument control, data processing tools, spectral calculator,<br />
quantitative predictions, Spectrum Search, and Report<br />
Builder. Spectrum BX manuals are also included. Upgrade<br />
includes Spectrum and Spectrum Search only. If upgrades<br />
to other software packages are required, these must be<br />
ordered separately.<br />
Part No. Each (€)<br />
Spectrum RX PC Software Upgrade<br />
L1100981 788<br />
Software kit to allow existing stand-alone Spectrum RX users<br />
to control the instrument with a PC. Includes Spectrum v5.0<br />
software, instrument control, data processing tools, spectral<br />
calculator, quantitative predictions, Spectrum Search, and<br />
Report Builder. IR Spectroscopy Software manual also<br />
included. The license number will refer to a Spectrum BX.<br />
This is also a valid license number for a Spectrum RX. When<br />
installed the instrument will be referred to in the software as<br />
a Spectrum BX. Requires, but does not include, RS232<br />
Communications Cable (09410022).<br />
Part No. Each (€)<br />
LX108689 2299<br />
Software Infrared Spectroscopy<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
263
Software Upgrade Kits<br />
Spectrum Infrared Software<br />
Infrared Spectroscopy Software Upgrade Kits<br />
Spectrum One Enhanced<br />
Security Software Upgrades<br />
Spectrum One ES v6.0 provides the power of Spectrum<br />
One v6.0 with the added benefit of 21 CFR Part 11 technical<br />
compliance. Spectrum One ES v6.0 achieves the highest<br />
standard for technical compliance in data security and<br />
integrity by the use of a proprietary security component and<br />
the implementation of audit trails, data security, and integrity<br />
features by 21 CFR Part 11 trained software engineers.<br />
Key compliance features:<br />
Full 21 CFR Part 11 technical compliance<br />
Password protected access control<br />
Multilevel user permissions<br />
Comprehensive audit-trailing<br />
Legacy data tool<br />
Available for Spectrum One/100, Spectrum One NTS/100N,<br />
and Spectrum GX<br />
Spectrum One ES v6.0 Upgrade<br />
License to upgrade prior Spectrum software versions to<br />
Spectrum One ES v6.0. Includes Spectrum One ES v6.0<br />
software, instrument control, data processing tools, spectral<br />
calculator, quantitative predictions, legacy data converter,<br />
reporting software plus an administration utility to set<br />
access control permissions to the software. 5-user and<br />
10-user licenses are available to enable customers who<br />
have already purchased a single-user license to install the<br />
software on additional systems. Spectrum One manuals<br />
are also included. Purchase of single-user license upgrade<br />
(LX108849 or LX108850) is a pre-requisite for purchase<br />
of 5-user and 10-user licenses.<br />
Prior Spectrum Software Version License Qty. Part No. Each (€)<br />
Spectrum CFR 4.0 Single-user LX108849 1314<br />
5-user LX100847 3284<br />
10-user LX100850 5300<br />
Spectrum v3.02 or earlier Single-user LX108850 3941<br />
5-user LX100847 3284<br />
10-user LX100850 5300<br />
Spectrum One NTS ES v6.0 Upgrade<br />
License to upgrade prior Spectrum software versions to<br />
Spectrum One NTS ES v6.0. Includes Spectrum One NTS<br />
ES v6.0 software, instrument control, data processing tools,<br />
spectral calculator, quantitative predictions, legacy data<br />
converter, reporting software plus an administration utility<br />
to set access control permissions to the software. 5-user<br />
and 10-user licenses are available to enable customers<br />
who have already purchased a single-user license to install<br />
the software on additional systems. Spectrum One NTS<br />
manuals are also included. Purchase of single-user license<br />
upgrade (LX108849 or LX108850) is a pre-requisite for<br />
purchase of 5 and 10-user licenses.<br />
Prior Spectrum Software Version License Qty. Part No. Each (€)<br />
Spectrum CFR 4.0 Single-user LX108849 1314<br />
5-user LX100847 3284<br />
10-user LX100850 5300<br />
Spectrum v3.02 or earlier Single-user LX108850 3941<br />
5-user LX100847 3284<br />
10-user LX100850 5300<br />
Spectrum GX ES v5.0 Upgrade<br />
Single-user license for Spectrum v3.02 or earlier to<br />
Spectrum GX ES v5.0 upgrade. Includes Spectrum GX ES<br />
v5.0 software, instrument control, data processing, spectral<br />
calculator, quantitative predictions, legacy data converter,<br />
reporting software, plus an administration utility to set access<br />
control permissions to the software.<br />
Spectrum GX manuals and an<br />
Part No. Each (€)<br />
administrators guide are also included. L1100974 3941<br />
264
Upgrade Kits<br />
Detector, Microscope, and Spectrum One/100 Upgrades<br />
Detector Upgrades<br />
Spectrum One/100 Upgrades<br />
MCT Mid-IR Detector Upgrade Kit<br />
Spectrum One/100 Systems can be upgraded to include<br />
an MCT Detector using one of these kits. Includes MCT<br />
Detector, MCT pre-amp, additional optics, and hardware.<br />
For instruments with serial number 53300 or lower, an<br />
MCT Casting Conversion Kit (L1200220) is also required<br />
and must be ordered separately.<br />
Description Part No. Each (€)<br />
NB 1 mm L1200236 7500<br />
MB 1 mm L1200237 7500<br />
WB 1 mm L1200238 7500<br />
MCT Casting Conversion Kit<br />
This conversion kit is required when<br />
upgrading Spectrum One Systems<br />
installed before September, 1999<br />
with an MCT Detector.<br />
Microscope Upgrades<br />
Microscope Upgrade Kit MultiScope Systems*<br />
This kit upgrades the MultiScope microscopes that are<br />
currently used with Spectrum RX, Spectrum BX, Spectrum/<br />
Paragon 1000, or the 1600 Series FT-IR Spectrometers to<br />
enable them to be interfaced with a<br />
Spectrum One spectrometer.<br />
Part No. Each (€)<br />
L1200390 1611<br />
Microscope Upgrade Kit for AutoIMAGE Systems*<br />
This kit upgrades AutoIMAGE system microscopes that are<br />
currently used with Spectrum RX, Spectrum BX, Spectrum/<br />
Paragon 1000, or the 1600 Series FT-IR Spectrometers to<br />
enable them to be interfaced to a Spectrum One<br />
spectrometer.<br />
Part No. Each (€)<br />
* Spectrum GX, Spectrum 2000, and System 2000 microscopes cannot be<br />
upgraded to be used with a Spectrum One system.<br />
Germanium ATR Objective Upgrade Kit<br />
Part No.<br />
Each (€)<br />
L1200220 256<br />
L1200392 1611<br />
This kit upgrades the MultiScope System, or the<br />
AutoIMAGE System Microscope without ATR Objective<br />
to include ATR Objective facility. This is a field fit option<br />
including cassegrain, mount, and germanium micro-ATR<br />
crystal with holder. A spare germanium crystal with holder<br />
is also included.<br />
Part No. Each (€)<br />
L1860298 7900<br />
LCD Touch-Screen Upgrade<br />
Spectrum One NTS systems<br />
without an LCD touch screen can<br />
be upgraded with this kit.<br />
Left-Side FT-NIR External Beam<br />
Kit (Microscope Compatible)<br />
L1240204 1208<br />
Allows for connection of AutoIMAGE<br />
microscope system. For use with the Spectrum One NTS.<br />
Spectrum One Infrared Sample Compartment<br />
Includes Sample Base Plate, Slide Mount, and Sample<br />
Compartment Covers. Allows for traditional infrared<br />
measurements to be made on Analyzer<br />
Systems such as the Edible Oil<br />
Analyzer or Used Oil Analyzer.<br />
Part No.<br />
L1200302<br />
Each (€)<br />
2684<br />
Spectrum One/100 Sample Shuttle<br />
Allows sample to be moved in and out of infrared beam for<br />
automatic background correction<br />
during sample measurement.<br />
Part No. Each (€)<br />
Spectrum One Base-Plate<br />
Includes sample base-plate and sample slide mount. Can be<br />
used to permanently mount a sampling accessory. When the<br />
accessory is required to do an infrared measurement, the<br />
accessory and base-plate can simply<br />
be pushed into the Spectrum One<br />
sample compartment area.<br />
Part No.<br />
L1200254<br />
Each (€)<br />
425<br />
Spectrum One Left-Hand Side<br />
External Beam Upgrade<br />
Part No.<br />
Each (€)<br />
L1200223 2013<br />
Part No.<br />
Each (€)<br />
L1200301 616<br />
Spectrum One systems without an external beam merging<br />
from the left-hand side of the instrument can be upgraded<br />
with these kits.<br />
Description Part No. Each (€)<br />
KBr L1200205 1232<br />
Upgrade Kits Infrared Spectroscopy<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
265
©2005 PerkinElmer, Inc. Microsoft is a registered trademark of Microsoft Corporation in the United States and other countries. 400083_03<br />
Getting perfect results is now<br />
a walk in the park<br />
Upgrade to a better lab experience<br />
with the NEW PerkinElmer Spectrum 100 FT-IR Spectrometers<br />
Experience the Spectrum 100 FT-IR and 100N FT-NIR and enjoy all the benefits of having unparalleled<br />
quality and reliability. You’ll achieve harmony in your lab and gain perfect results with these easy-to-use<br />
instruments. The Spectrum 100 Series is packed with everything you need to succeed and backed by<br />
the expertise of PerkinElmer ® , so you can breathe easier every single day.<br />
See how the Spectrum 100 Series delivers the performance and reliability essential to your lab.<br />
Just go to www.perkinelmer.com/spectrum100<br />
Or, call 1 800-762-4000 (North America) or (+1) 203-925-4602<br />
Visit www.perkinelmer.com/lasoffices for a listing of our global offices.
PerkinElmer offers a comprehensive line of<br />
High Performance Liquid Chromatography (HPLC)<br />
systems to meet your lab’s every requirement. The<br />
PerkinElmer Series 200 HPLC family was designed<br />
to meet and exceed the liquid chromatography<br />
demands of your lab. It offers a fully modular<br />
scalable system structure – meaning no compromises<br />
on functionality or performance. Best of all,<br />
every PerkinElmer instrument is backed by our<br />
renowned global service and support organization.<br />
Liquid Chromatography<br />
Acquiring, processing, reporting, reviewing<br />
and approving data are a streamlined series<br />
of operations in PerkinElmer’s TotalChrom ®<br />
Chromatography Data System (CDS) software,<br />
designed to fit your laboratory workflow and<br />
maximize productivity. TotalChrom data systems<br />
can be deployed in stand-alone, thin client or<br />
enterprise client/server computing environments.
Liquid Chromatography<br />
QUICK-FIND INDEX Page #<br />
Autosampler Trays 270<br />
Autosampler Vials, Caps<br />
and Septa 271<br />
PerkinElmer offers a wide selection of superior quality products designed to work with<br />
your PerkinElmer instruments. Our precision-designed products deliver the peace of<br />
mind that comes from knowing that you’ll get the results you need.<br />
The Quick Find Index to the left will help you find products fast. For your convenience,<br />
products are alphabetized by category, sub-category, and family. There is also a more<br />
complete Alphabetical INDEX on page 429 and a Part Number INDEX on page 407.<br />
Cartridge Columns 274<br />
Check Valves 319<br />
Conventional Columns 294<br />
Conventional Guard Cartridges<br />
and Accessories 313<br />
Degassing Systems 318<br />
Detector Lamps 316<br />
Deuterium Lamps<br />
PerkinElmer Deuterium Lamps for the Series 200 UV/Vis<br />
Detector, provide outstanding performance and longevity.<br />
Deuterium lamps are warranteed for at least 500 hours of<br />
operation. Lamp replacement is quick and easy due to a<br />
self-aligning lamp mount.<br />
Page 316<br />
Detectors 314<br />
Dynamic Mixers 321<br />
Fittings 323<br />
ISS-200 Supplies 273<br />
LC Column Ovens 317<br />
Peltier Trays 270<br />
Pistons and Piston Seals 319<br />
Pump Accessories 321<br />
Rheodyne Injection Valves 324<br />
Sample Introduction 327<br />
Supplies and Accessories 323<br />
Syringes 273<br />
TotalChrom Chromatography<br />
Software 328<br />
Autosampler Vials, Caps, and Septa<br />
Brownlee Columns<br />
PerkinElmer Autosampler vials and caps are guaranteed to<br />
fit and are compatible with the Series 200 Autosampler.<br />
Vials and caps are inert to samples ordinarily analyzed by<br />
Liquid Chromatography. Septa are designed specifically for<br />
autosampler needle to prevent bending, breakage, or coring<br />
of the septa.<br />
Page 271<br />
Brownlee TM Conventional and Cartridge Columns for Reversed<br />
Phase, Normal Phase and Ion Exchange Chromatography<br />
modes of separation. Conventional columns use standard<br />
compression end fittings compatible with all HPLC<br />
instrumentation. Each column is individually tested. Brownlee Cartridge Columns are<br />
available in three lengths and two internal diameters. The MPLC cartridge system<br />
allows direct coupling of a cartridge to a guard without any dead volume. NewGuard ®<br />
Cartridge Columns prolong column life two to five fold by eliminating particulates<br />
and contaminant's.<br />
Page 274<br />
Online Vacuum Degassing Systems<br />
Extend the performance of your pump by using a Degassing<br />
System. The Series 200 Vacuum Degasser is a low-volume,<br />
high efficiency, online module for removal of dissolved gasses<br />
from HPLC solvents. The vacuum degasser is available in<br />
three and five channel models to support isocratic, binary<br />
and quaternary pumps as well as degassing of autosampler<br />
flush solvent.<br />
Page 318
PerkinElmer Series 200<br />
HPLC Systems<br />
Designed to<br />
Never<br />
Let You Down<br />
HPLC Series 200<br />
PerkinElmer knows you need to rely<br />
on your high performance liquid<br />
chromatography (HPLC) system to<br />
get the job done day-in and day-out.<br />
That’s why we designed and built the<br />
Series 200 system of HPLC instruments.<br />
We’re confident the Series 200 HPLC<br />
systems will meet and exceed the liquid<br />
chromatography demands of your lab,<br />
because each component – from pump<br />
to data handling – has a proven track<br />
record behind it. Best of all, all of our<br />
systems are backed by our renowned<br />
global service and support organization,<br />
so you know you can depend on them<br />
today, tomorrow, and for years to come.<br />
SoftLINK TM : entry-level solution<br />
for instrument connectivity<br />
Designed for instrument workstation<br />
environments, SoftLINK provides<br />
instrument connectivity at a glance.<br />
dotLINK TM : interfacing with ease<br />
dotLINK is a Windows CE-based<br />
interface that allows you to connect<br />
your Series 200 directly to the<br />
network. Designed to face today’s<br />
workload challenges and provide<br />
Ethernet connectivity, dotLINK allows<br />
external buffering with a minimal<br />
need for validation.<br />
269
Liquid Chromatography Autosampler Supplies and Accessories<br />
Autosampler Supplies and Accessories<br />
Autosampler Trays and Plates<br />
Peltier Tray Accessories<br />
100-Position Peltier Temperature-Controlled<br />
Tray Accessory<br />
100 standard 2 mL vials. Temperature controlled from<br />
4-60° C within ± 1° C directly from Autosampler keypad –<br />
or from TotalChrom Workstation – Client/Server.<br />
Double Microtiter Peltier<br />
Temperature-Controlled Tray Accessory<br />
Two shallow or medium depth microtiter plates. Temperature<br />
controlled from 4-60° C within ± 1° C directly from Autosampler<br />
keypad – or from TotalChrom Workstation – Client/Server.<br />
(Also requires N2930036).<br />
Part No. Each (€)<br />
Peltier Temperature Controller<br />
Controller Unit required for operation<br />
of either 100-position or Double<br />
Microtiter Peltier trays.<br />
Part No.<br />
Part No.<br />
Each (€)<br />
N2930035 1454<br />
N2930037 1454<br />
Each (€)<br />
N2930036 1849<br />
Series 200 Autosampler Microtiter Trays and Plates<br />
100-Position Peltier Temperature-Controlled Tray Accessory<br />
Part No. N2930035<br />
Sample Trays<br />
PerkinElmer has researched, engineered, and developed<br />
the Series 200 Autosampler to ensure precision, flexibility,<br />
reliability, and ease-of-use.<br />
Our unique XYZ design allows you to take advantage<br />
of the built-in “extra” capabilities including dilution,<br />
derivatization, and standard addition – all without<br />
additional hardware or cost.<br />
Description Part No. Each (€)<br />
25-Position Sample Tray N2930040 351<br />
80-Position Sample Tray, Dilution (with tank) N2930314 625<br />
Includes: 80-Position Tray Only N2930044 395<br />
Glass Diluent Tank Only B0505677 398<br />
85-Position Sample Tray, Derivatization N2930041 351<br />
100-Position Sample Tray N2931097 351<br />
205-Position Sample Tray, Microvials/10 standard vials N2930042 351<br />
225-Position Sample Tray, Microvials/high throughput N2930043 351<br />
If you need high throughput and high speed, the Series 200 is designed for injecting up to 225 samples at rates as fast as<br />
two to three injections per minute from any sample position – ideal for LC/MS work. The Series 200 even supports direct<br />
injections from microtiter plates – shallow or deepwell format.<br />
Tray Description Part No. Each (€) Microtiter Plates Description Part No. Each (€)<br />
Double Deep Microtiter Tray N2930147 332 96-well Deep (1mL) N9302560 8<br />
(Holds two 96-well Plates) 96-well Plate Cover/Mat N9302563 5<br />
Double Microtiter Peltier Tray N2930037 1454 96-well Shallow (200 μL) N9302562 5<br />
Requires Peltier Controller (N2930036) 96-well Mid (500 μL) N9302561 7<br />
(Holds two 96-well Plates) 96-well Plate Cover/Mat N9302563 5<br />
Double Shallow Microtiter Plate Tray N2930146 332 96-well Shallow (200 μL) N9302562 5<br />
(Holds two 96-well Plates) 96-well Mid (500 μL) N9302561 7<br />
96-well Plate Cover/Mat N9302563 5<br />
Peltier Tray for 384-well Microtiter Plates N2930038 1454 384-well Plate (200 μL) N9302564 10<br />
Requires Peltier Controller (N2930036) and 384-well Plate Cover/Mat N9302565 197<br />
Series 200 Autosampler Firmware 1.08 or higher.<br />
270
0.2 mL Micro Vials,<br />
Caps, and Septa<br />
Caps/Septa<br />
Description Part No. Each (€)<br />
Polyethylene press-on cap for 8 mm o.d. vials N9302141 140<br />
(pkg. 1000)<br />
Aluminum crimp-top cap with Teflon-lined butyl 03300806 171<br />
rubber septa for 8 mm vials (pkg. 1000)<br />
Crimp Top Vials<br />
Glass microVials, tapered,<br />
0.2 mL, 8 mm o.d. top. (pkg. 500)<br />
Glass Autosampler Vial Sleeve<br />
Polyethylene Micro Vial Kit<br />
Includes 300 μL tapered vial, blue<br />
polypropylene cap with bonded<br />
silicone/PTFE septa. (pkg. 500)<br />
2.0 mL Vials, Caps and Septa<br />
PerkinElmer Autosampler vials are guaranteed for fit and<br />
compatibility with the Series 200 Autosampler. Both vials<br />
and caps are totally inert to samples ordinarily analyzed by<br />
Liquid Chromatography.<br />
Crimp Caps<br />
Description Size Part No. Each (€)<br />
Crimp Green (pkg. 100) 11 mm N9302684 35<br />
Aluminum cap with Teflon ® /rubber<br />
Crimp Red (pkg. 100) 11 mm N9302685 37<br />
Aluminum cap with Teflon/rubber<br />
Series 200 Autosampler<br />
Autosampler Supplies and Accessories<br />
Part No.<br />
Each (€)<br />
N9302136 357<br />
Part No.<br />
Each (€)<br />
N9307027 159<br />
Part No.<br />
Each (€)<br />
N9306080 557<br />
Compatibility Table for Vials and Caps in Sample Trays<br />
Autosampler Vials and Caps<br />
Description Size Part No. Each (€)<br />
Crimp Blue (pkg. 100) 11 mm N9302686 41<br />
Aluminum cap with Teflon/rubber<br />
Crimp Silver (pkg. 100) 11 mm N9306015 25<br />
Aluminum cap with Teflon/rubber<br />
Crimp Top Vials<br />
Type 1 borosilicate standard glass vials, 2.0 mL,<br />
11 mm o.d. top.<br />
Description Part No. Each (€)<br />
Amber glass (pkg. 100) N9302680 31<br />
Clear glass (pkg. 100) N9301385 18<br />
Screw Top Vials and Caps – Wide Mouth<br />
Type 1 borosilicate standard glass vials,<br />
2.0 mL, 12 x 32 mm.<br />
Description Size Part No. Each (€)<br />
Amber Glass (pkg. 100) N9306057 20<br />
Clear Glass (pkg. 100) N9306053 19<br />
Screw Black (pkg. 100) 10 mm N9306052 45<br />
Polypropylene with PTFE/slit<br />
white silicone<br />
6 mL Vials and Caps<br />
Part No.<br />
Part No.<br />
Each (€)<br />
N9302143 56<br />
Each (€)<br />
N9302134 101<br />
Vials<br />
Caps<br />
Volume Series 200 Tray Part No. Each (€) Part No. Each (€)<br />
0.2 mL* 205-Position N9302136 357 N9302141 140<br />
225-Position<br />
2.0 mL - Crimp Top 81-Position N9302680 31 N9302684 35<br />
85-Position N9301385 18 N9302685 37<br />
100-Position N9302686 41<br />
105-Position Peltier N9306015 25<br />
205-Position<br />
2.0 mL - Screw Top 81-Position N9306053 19 N9306052 45<br />
85-Position N9306057 20<br />
100-Position<br />
100-Position Peltier<br />
205-Position<br />
6.0 mL 25-Position N9302134 101 N9302143 56<br />
85-Position<br />
* Requires N9307027 sleeves<br />
Caps/Septa<br />
Polyethylene press-on cap<br />
for 20 mm o.d. vials. (pkg. 250)<br />
Crimp Top Vials<br />
Glass large-volume vials,<br />
6.0 mL, 20 mm o.d. top. (pkg. 125)<br />
Autosampler Supplies and Accessories Liquid Chromatography<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
271
Liquid Chromatography Autosampler Supplies and Accessories<br />
Autosampler Supplies and Accessories<br />
Autosampler Vial Crimping Tools<br />
Crimpers<br />
PerkinElmer also provides crimpers for a variety of cap<br />
sizes. Crimp capping is still a preferred method by some<br />
laboratories to ensure sample integrity, particularly those<br />
containing volatile compounds.<br />
Bench Top Vial Crimper<br />
Without jaws.<br />
Bench Top Vial Crimper Jaws<br />
For 11 mm vials.<br />
Bench Top Vial Crimper Jaws<br />
For 20 mm vials.<br />
Economy Cap Removal Tool<br />
20 mm.<br />
Vial Crimper<br />
For 11 mm o.d. top vials.<br />
Part No.<br />
Each (€)<br />
N6621006 1685<br />
Part No.<br />
Each (€)<br />
N6621008 391<br />
Part No.<br />
Each (€)<br />
N6621009 344<br />
Part No.<br />
Each (€)<br />
N9301270 64<br />
Part No.<br />
Each (€)<br />
00090699 263<br />
Electronic Crimpers<br />
New from PerkinElmer, the 11 mm electronic crimpers<br />
and decappers are easy to use and fully rechargeable.<br />
Ergonomically designed to alleviate the potential for carpal<br />
tunnel syndrome and provide a consistent crimp pressure<br />
numerous times. The electronic crimper is provided with<br />
a standard Black and Decker VersaPak ® Gold battery and<br />
charging unit. This handheld device will crimp several<br />
hundred vials on one charge. Crimping pressure is fully<br />
adjustable for precision control. Also available in 20 mm.<br />
Features and Benefits:<br />
Precision control crimping<br />
Ergonomically designed grip<br />
Numerous reproducible crimps<br />
from a single charge<br />
Includes standard Black and Decker<br />
VersaPak Gold battery and charger<br />
Description Voltage Part No. Each (€)<br />
11 mm Electronic Crimper 120 V N9302567<br />
11 mm Electronic Crimper 230 V N9302569 700<br />
11 mm Electronic Crimper 240 V N9302570 700<br />
11 mm Electronic Decapper 120 V N9302575<br />
11 mm Electronic Decapper 230 V N9302577 700<br />
11 mm Electronic Decapper 240 V N9302579 700<br />
Electric Crimper Battery N9302585 44<br />
272
Autosampler Syringes Series 200<br />
Description Size Part. No. Each (€)<br />
Sampling Syringe 50 μL 09923304 281<br />
Sampling Syringe 100 μL 09923305 281<br />
Sampling Syringe 250 μL 09923270 281<br />
Sampling Syringe 500 μL 09923306 281<br />
Sampling Syringe 1000 μL 09923307 281<br />
Sampling Syringe 2500 μL 09923219 281<br />
Requires one-time purchase of<br />
Sampling Syringe Kit (N2930313)<br />
Sampling Syringe Kit 2500 μL N2930313 281<br />
Includes: 2500 μL syringe, union,<br />
and tubing kit<br />
Flush Syringe 2500 μL 09923219 281<br />
\<br />
BCD Cables<br />
Series 200 Autosampler 1022 BCD Cable<br />
REM Box.<br />
Series 200 Autosampler TotalChrom TM /<br />
Turbochrom TM BCD Cable<br />
900 Interface.<br />
ISS-200 Injector Valve<br />
Parts for BSW Valves<br />
Description Part No. Each (€)<br />
Rotor Seal B0185480 91<br />
Stator B0162836 229<br />
ISS-200 Sample Trays<br />
Description Part No. Each (€)<br />
100-Position Sample Tray B0198017 930<br />
150-Position Sample Tray B0198016 640<br />
Autosampler Supplies and Accessories<br />
Part No.<br />
Part No.<br />
Each (€)<br />
N2930341 295<br />
Each (€)<br />
N2930340 242<br />
ISS-200 and Series 200 Autosampler<br />
ISS-200 Spares<br />
Description Part No. Each (€)<br />
Dosing Pump (250 μL) B0193780 2420<br />
Dosing Pump (1500 μL) B0506592 1761<br />
Dosing (Sample) Pump Piston (250 μL) B0092468 349<br />
Dosing Pump Piston Seal (250 μL) B0133956 175<br />
Flush Pump Inlet Check Valve B0105973 437<br />
Flush Pump Outlet Check Valve B0105974 359<br />
Flush Pump Piston B0092456 372<br />
Flush Pump Piston Head B0170873 465<br />
Flush Pump Piston Seal B0170875 42<br />
Flush Solvent Filter B0193766 137<br />
with Teflon ® tubing, nuts, and ferrules<br />
PerkinElmer Injection Valve Assembly B0185259 2771<br />
(w/150 μL loop)<br />
Sampling Needle 02540582 99<br />
Serial Dilution Tank B0505677 398<br />
Teflon Transfer Tube 02506495 1<br />
Tefzel Sample Transfer Tube B0121084 49<br />
for Prep Option Kit<br />
Manuals<br />
User’s Manual Series 200<br />
User’s Manual ISS-200<br />
Replacement Parts Series 200<br />
Part No.<br />
Each (€)<br />
09938912 97<br />
Part No.<br />
Each (€)<br />
B0198180 790<br />
Description Size Part. No. Each (€)<br />
Delrin Nut 1/16 in. 09920381 7<br />
Fingertight Nut (qty. 1) 09920513 17<br />
Flush Reservoir Filter 40 μm SS 09903615 68<br />
Flush Reservoir Filter 40 μm Ti N2600089 75<br />
Needle Cartridge Cap Screw N2931064 38<br />
Needle Cartridge Casting N2931012 197<br />
Needle Cartridge Thumb Screw 09920672 6<br />
Needle Spring 09920429 1<br />
Stainless Steel Injector Needle N2930023 140<br />
Stainless Steel Sample Holding Loop N2930311 281<br />
Teflon Transfer Line Per Ft 02506495 1<br />
Tefzel Reverse Ferrule 1/16 in. 09920382 4<br />
Tefzel Union 09920391 34<br />
no nuts or ferrules<br />
Titanium Injector Needle N2930024 389<br />
Titanium Sample Holding Loop N2930312 414<br />
Union 1/16 in. 09903289 92<br />
Union Holder Arm N2931081 35<br />
Note: See the Rheodyne Valve section for injection valves spares<br />
Autosampler Supplies and Accessories Liquid Chromatography<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
273
Cartridge Columns<br />
Brownlee Cartridge Columns<br />
Analytical Cartridges for<br />
Conventional and Narrowbore HPLC*<br />
Analytical cartridges from the Brownlee TM line are available in three<br />
lengths (30, 100, and 220 mm), and two internal diameters (4.6 and<br />
2.1 mm). The MPLC cartridge system allows direct coupling of a<br />
cartridge to a guard without any dead volume. Changing cartridges<br />
is easy with the finger-tight cartridge design which does not require<br />
any wrench-tightening of the holder or disconnecting of tubing<br />
from the LC system. A specific cartridge holder is required for each<br />
cartridge length. Additional information on MPLC holders can<br />
be found on page 293. Pressure ratings are 7,000 psi for silicabased<br />
columns.<br />
■ Quality: Columns are manufactured under stringent ISO-9001 certified<br />
quality control standards. Individual test chromatograms are included<br />
with each 100 mm and 220 mm cartridge.<br />
■ Flexible: Same reusable holder for 4.6 and 2.1 mm i.d. cartridges.<br />
Compatible with all HPLC instruments. Choice of different cartridge<br />
lengths to enhance speed or resolution.<br />
■ Economical: Cartridges are less expensive than conventional columns.<br />
Solvent consumption reduced by using narrowbore or shorter columns.<br />
■ Experience: 25 years of manufacturing experience since Bob Brownlee<br />
introduced the first finger-tight cartridge system in 1977.<br />
* Microbore, semi-preparative and conventional MPLC columns<br />
found on pages 290.<br />
Brownlee Sorbents<br />
Brownlee offers a wide selection of sorbents based on both silica<br />
and polymer supports.<br />
Aquapore ® is a wide-pore (300 Å, 7, and 20 μm), silica-based<br />
support suitable for the separation of large biopolymers.<br />
Spheri-5 ® is a small-pore (80 Å, 5 μm), silica-based sorbent for<br />
separating small molecules. Both monofunctional (comb-type)<br />
and polyfunctional (polymerized loop-type) C8 and C18 sorbents<br />
are available.<br />
Polypore ® is a polymer-based (microporous, 10 μm) sorbent<br />
for the analysis of organic acid and sugars.<br />
Validated is a small-pore (100 Å, 5 μm) silica-based C18<br />
sorbent for small molecules, specifically for consistent<br />
pharmaceutical assays.<br />
Brownlee Columns and Holders<br />
Reduced Activity is a small-pore, base-deactivated (100 Å, 3,<br />
and 5 μm) silica-based, reversed-phase sorbent (C18 or C8)<br />
developed for HPLC of basic analytes and pharmaceuticals.<br />
CHOICE is a small-pore, base-deactivated (100 Å, 3 μm C18)<br />
silica-based, reversed-phase sorbent (C18) developed for<br />
LC/MS separations.<br />
Modes of Separation<br />
Reversed-Phase Chromatography (RPC) is the most popular HPLC<br />
mode and is used in 60-80% of all applications. In RPC, hydrophobic<br />
groups (C18, C8, or C4) bonded to a silica support are used together<br />
with a mobile phase of water and organic solvent<br />
(e.g. methanol, acetonitrile).<br />
Polar Phase (Normal Phase) Chromatography (NPC) uses a polar<br />
stationary phase (unbonded silica, bonded amino or cyano group)<br />
together with a nonpolar mobile phase (e.g., hexane). NPC is useful<br />
for functional group analysis, isomeric separations, purification of<br />
organics, and sample cleanup.<br />
Ion-Exchange Chromatography (IEC) utilizes bonded ionic groups to<br />
separate ionic analytes. Retention is based on the affinity of various<br />
analyte ions for the stationary phase and various mobile phase<br />
parameters (e.g., pH, ionic strength).<br />
Pecosphere is a small-pore (80 Å, 3, 5, and 10 μm) silica-based<br />
sorbent for HPLC of small molecules.<br />
274
Column Selection Guide<br />
Cartridge Columns<br />
Brownlee Cartridge Column Selection and Specification Guide<br />
Molecular Weight Solubility Mode Sorbent<br />
2000 Water Ion exchange Aquapore AX-300<br />
Wide-pore reversed phase Aquapore OD-300, RP-300, BU-300<br />
Column Selection Guide for Biological Applications<br />
Molecular Weight<br />
Mode<br />
Proteins Wide-pore reversed phase Aquapore OD-300, RP-300, BU-300<br />
Ion exchange<br />
Aquapore AX-300<br />
Peptides Reversed phase Validated , Peco Red. Act.-3 and 5, CHOICE<br />
Wide-pore reversed phase Aquapore OD-300, RP-300, BU-300<br />
Ion exchange<br />
Aquapore AX-300<br />
Amino acids Reversed phase Spheri-5 RP-18, Validated<br />
Oligonucleotides, Nucleotides Wide-pore reversed phase Aquapore OD-300, RP-300, Speri-5 RP-18, CHOICE<br />
Ion exchange<br />
Aquapore AX-300<br />
Nucleosides Reversed phase Spheri-5 RP-18, CHOICE<br />
Organic acids Mixed mode Polypore H<br />
Sugars Mixed mode Polypore CA<br />
Specific Recommendations<br />
■<br />
■<br />
■<br />
■<br />
■<br />
■<br />
■<br />
Pharmaceutical/Clinical: Validated, Red. Act.-3<br />
Protein/Peptides: Aquapore OD-300, RP-300, BU-300<br />
DNAs/Polynucleotides: Aquapore RP-300<br />
Industrial/Food: Spheri-5, Pecosphere, Red. Act.-3<br />
Environmental: Spheri-5, Pecosphere, Red. Act.-3<br />
Sugars: Spheri-5 Amino, Polypore CA<br />
Organic Acids/Alcohols: Polypore H<br />
Cartridge Columns Liquid Chromatography<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
275
Cartridge Column Applications<br />
Column Application Notes<br />
Liquid Chromatography Cartridge Column Applications<br />
Subject<br />
Page No.<br />
Biotechnology<br />
Human Serum Profile 277<br />
Nucleosides and Bases 277<br />
Organic Acids 277<br />
Tryptic Digest of Glycoprotein Human IgA 277<br />
Clinical<br />
Barbiturates 278<br />
Theophylline 278<br />
Environmental<br />
Diquat and Paraquat 278<br />
Phenol Priority Pollutants 278<br />
Food<br />
Analysis of OPA Precolumn Derivatives of Amino Acids 279<br />
Analysis of Sugars (resin column) 279<br />
Analysis of Organic Acids 279<br />
Fat-soluble Vitamins in Animal Feeds 279<br />
Olive Oil Triglycerides 280<br />
Organic Acids in Fruit Juice 280<br />
Sweetener in Beverage 280<br />
Water-Soluble Vitamins in Animal Feeds 280<br />
Industrial<br />
Epoxy Resin 281<br />
Hexachlorophene 281<br />
Polystyrene Additives 281<br />
Short-Chain Fatty Acids 281<br />
Pharmaceutical<br />
Analgesics in Tablets 282<br />
Analgesics/Anti-inflammatory 282<br />
Antihistamines 282<br />
Benzodiazepines 282<br />
Carbamazepine in Serum 283<br />
Cardiac Drugs 283<br />
Chlorthalidone HPLC Assay 283<br />
Estrogenic Steroids 283<br />
Parabens in Hand Cream 284<br />
Phenothiazines 284<br />
Prednisone in Tablet Prep 284<br />
The LC/MS of Quinolone Antibiotic Degradation Products 284<br />
276
Cartridge Column Applications<br />
Biotechnology Applications<br />
Human Serum Profile<br />
1<br />
CHROMATOGRAPHIC CONDITIONS<br />
Column: Pecosphere 5 C18 (150 x 4.6 mm, 5 μm)<br />
Detection: UV at 254 nm<br />
Mobile Phase: A: 60% MeOH/H 2 O<br />
B: 0.02 M NaH 2 PO 4 in pH 5.6<br />
Linear gradient from 0.5% – 40% A in 7 min.<br />
Flow Rate: 2.0 mL/min.<br />
Pressure: 2,200 psi (15 MPa)<br />
Inj. Volume: 10 μL of deproteinized serum<br />
Nucleosides and Bases<br />
Peak Identification<br />
2 4<br />
5<br />
3<br />
1. Cytosine<br />
2. Uracil<br />
3. Cytidine<br />
4. Uridine<br />
5. Hypoxanthine<br />
6. Xanthine<br />
7. Thymine<br />
8. Inosine<br />
9. Guanosine<br />
10. Thymidine<br />
11. Adenine<br />
12. Adenosine<br />
6<br />
7<br />
8<br />
Peak Identification<br />
CHROMATOGRAPHIC CONDITIONS<br />
Column: Pecosphere 5 C18 (150 x 4.6 mm, 5 μm)<br />
Detection: UV at 254 nm<br />
Mobile Phase: A: 60% MeOH/H 2 0<br />
B: 0.02 M NaH 2 PO 4 in pH 5.5 aqueous buffer<br />
gradient 0.5% – 40% A in 3 min.<br />
Flow Rate: 3.5 mL/min.<br />
Pressure: 3,500 psi (24 MPa)<br />
1. Creatinine<br />
2. Uric Acid<br />
3. Tyrosine<br />
4. Hypoxanthine<br />
5. Undine<br />
6. Xanthine<br />
7. Inosine<br />
8. Guanosine<br />
9. Tryptophan<br />
10. Theobromine<br />
11. Caffeine<br />
0 5 10<br />
MINUTES<br />
9<br />
10<br />
1<br />
2<br />
3<br />
4<br />
5<br />
6<br />
0 2 4<br />
MINUTES<br />
7<br />
8<br />
10<br />
9<br />
11<br />
11<br />
12<br />
Organic Acids<br />
Peak Identification<br />
1. Oxalic Acid<br />
2. Citric Acid<br />
3. α-Ketoguitaric<br />
Acid<br />
4. Malic Acid<br />
5. Succicinic Acid<br />
6. Formic Acid<br />
7. Acetic Acid<br />
8. Fumaric Acid<br />
9. Butyric Acid<br />
CHROMATOGRAPHIC CONDITIONS<br />
Column: Polypore H (220 x 4.6 mm i.d.)<br />
Detection: 210 nm<br />
Mobile Phase: 0.01 N H 2 SO 4<br />
Flow Rate: 0.15 mL/min.<br />
Temperature: 25 °C<br />
Part No. 02580169 Part No. 07110089<br />
Part No. 02580169<br />
Tryptic Map of Glycoproteins Human IgA<br />
ABSORBANCE<br />
1<br />
2<br />
3 4<br />
5<br />
6<br />
7<br />
0 10 20<br />
MINUTES<br />
0 10 20 30 40 50<br />
MINUTES<br />
CHROMATOGRAPHIC CONDITIONS<br />
Column: Aquapore RP-300 (7 μm, 300 Å, 220 x 2.1 mm)<br />
Detection: UV at 214 nm<br />
Mobile Phase: A: 0.1% TFA<br />
B: 0.1% TFA in ACN<br />
Flow Rate: 0.25 mL/min.<br />
Gradient: 2-70% B in 45 min.<br />
Sample: Tryptic digest of glycoprotein Human IgA 200 pmoles<br />
Part No. 07110060<br />
8<br />
9<br />
Cartridge Column Applications Liquid Chromatography<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
277
Cartridge Column Applications<br />
Clinical and Environmental Applications<br />
Liquid Chromatography Cartridge Column Applications<br />
Barbiturates<br />
Peak Identification<br />
1. Barbital<br />
2. Phenobarbital<br />
3. Aprobarbital<br />
4. Butabarbital<br />
5. Mephobarbital<br />
6. Amobarbital<br />
7. Pentobarbital<br />
8. Secobarbital<br />
CHROMATOGRAPHIC CONDITIONS<br />
Column: Pecosphere-3 x 3 C18 (33 x 4.6 mm i.d.)<br />
Detection: UV at 200 nm<br />
Mobile Phase: MeOH, 0.015 M (NH 4 ) 2 HPO 2 :H 2 O (55:20:25)<br />
Flow Rate: 2.5 mL/min.<br />
Sample: 3 μL injection: 0.1 mg/mL of each barbiturate<br />
Part No. 02580164<br />
Diquat and Paraquat<br />
ABSORBANCE<br />
310 nm<br />
1<br />
255 nm<br />
0 2 4<br />
MINUTES<br />
1<br />
2<br />
3<br />
4<br />
5<br />
0 1<br />
MINUTES<br />
CHROMATOGRAPHIC CONDITIONS<br />
Column: Two Pecosphere 3 x 3, silica (83 x 4.6 mm i.d., 3 μm)<br />
Detection: UV at 310 for diquat and 255 for paraquat<br />
Mobile Phase: Tetramethyl ammonium hydroxide 10 g/L,<br />
ammonium sulfate 30 g/L (in water)<br />
Flow Rate: 0.8 mL/min.<br />
Sample: 10 ng per component<br />
Temperature: 70 °C<br />
Part No. 02580167<br />
2<br />
3<br />
6<br />
7<br />
8<br />
Peak Identification<br />
1. Diquat<br />
2. Paraquat<br />
3. Ethylparaquat<br />
(internal standard)<br />
Phenol Priority Pollutants<br />
Peak Identification<br />
1. Phenol<br />
2. p-Nitrophenol<br />
3. o-chlorophenol<br />
4. 2, 4-Dinetrophenol<br />
5. o-Nitrophenol<br />
6. 2, 4 Dimethylphenol<br />
7. 4-Chloro-m-Cresol<br />
8. 2, 4-dichlorophenol<br />
9. 4, 6-Dinitro-o-Cresol<br />
10. 2, 4, 6-Trichlorophenol<br />
11. Pentachlorophenol<br />
CHROMATOGRAPHIC CONDITIONS<br />
Column: Pecosphere 3 C18 (83 x 4.6 mm i.d., 3 μm)<br />
Detection: UV at 254 nm<br />
Mobile Phase: Linear gradient of 35% acetonitrile/water (pH 2.2)<br />
to 100% acetonitrile in 4 min.<br />
Flow Rate: 2.5 mL/min.<br />
Inj. Volume: 6 μL injection volume; 0.1-0.2 mg/mL of each compound<br />
Part No. 02580166<br />
Theophylline<br />
Peak Identification<br />
1. Theobromine<br />
2. Theophyline<br />
3. ß-OH Ethyl Theophylline<br />
4. Caffeine<br />
CHROMATOGRAPHIC CONDITIONS<br />
Column: Pecosphere-3 x 3 C18 (33 x 4.6 mm i.d.)<br />
Detection: UV at 273 nm<br />
Mobile Phase: 11% CH 3 CN in H 2 O<br />
Flow Rate: 3.0 mL/min.<br />
Sample: 6 μL injection: 1-10 mg/L standards<br />
Part No. 02580164<br />
1<br />
2<br />
4<br />
3<br />
0 1 2 3 4 5<br />
MINUTES<br />
1<br />
5<br />
2<br />
6<br />
9<br />
7<br />
8<br />
3<br />
10<br />
0 15 30 45<br />
SECONDS<br />
4<br />
11<br />
278
Cartridge Column Applications<br />
Food Applications<br />
Absorbance (210 nm)<br />
Analysis of Organic Acids<br />
Org. Acid<br />
Acetic acid 80<br />
(mg/mL)<br />
CHROMATOGRAPHIC CONDITIONS<br />
Column: Polypore H (220 x 4.6 mm, 10 μm)/Polypore H guard<br />
column (30 x 4.6 mm)<br />
Detection: UV at 210 nm<br />
Mobile Phase: 0.01N H 2 SO 4<br />
Flow Rate: 0.3 mL/min. at room temp., 300 psi<br />
Sample: 5 μL of standard or vinegar sample diluted 1:4 in mobile phase<br />
Analysis of OPA Precolumn Derivatives of<br />
Amino Acids<br />
FLUORESCENCE<br />
White Vinegar<br />
Standard<br />
Asp<br />
oxalic<br />
Glu<br />
tartaric<br />
malic<br />
Ser<br />
CHROMATOGRAPHIC CONDITIONS<br />
Column: Pecosphere 3 x 3 C18 (33 x 4.6 mm i.d., 3 μm)<br />
Detection: Fluorescence 340 nm (Ex)/450 nm (Em)<br />
Mobile Phase: A: Methanol<br />
B: 1.5% THF in 50 mM NaOAc (pH 5.9)<br />
Linear gradient of 5% A to 80% A in 6.5 min.<br />
Flow Rate: 2.5 mL/min.<br />
Sample: Soy protein hydrolyzate sample derivatized with OPA<br />
Gly<br />
His<br />
succinic<br />
0 2 4 6 8 10 12 14<br />
MINUTES<br />
Part No. 07110089/07110085<br />
Arg<br />
Thr<br />
Ala<br />
Tyr<br />
Val<br />
Phe<br />
Leu<br />
0 4 8<br />
MINUTES<br />
Part No. 02580164<br />
formic<br />
acetic<br />
acetic<br />
propionic<br />
butyric<br />
Lys<br />
UV ABSORBANCE<br />
Analysis of Sugars<br />
RI Intensity<br />
CHROMATOGRAPHIC CONDITIONS<br />
Column: Polypore CA (220 x 4.6 mm, 10 μm)/Polypore CA guard<br />
column (30 x 4.6 mm)<br />
Detection: RI<br />
Mobile Phase: Water<br />
Flow Rate: 0.2 mL/min. at 75 °C, 100 psi<br />
Sample: 10 μL of standard or juice sample diluted 1:4 in water<br />
Fat-soluble Vitamins in Animal Feed Premix<br />
Feed Premix<br />
265 nm<br />
Grape Juice<br />
Apple Juice<br />
Standards<br />
0 10 20<br />
MINUTES<br />
1<br />
1<br />
sucrose<br />
2<br />
2<br />
glucose<br />
sucrose<br />
glucose<br />
sucrose<br />
glucose<br />
FSV Standards<br />
1. Vitamin A Acetate<br />
2. Vitamin D 2<br />
3. Vitamin E<br />
4. Vitamin E Acetate<br />
0.0 5.0 10.0 15.0<br />
MINUTES<br />
285 nm<br />
Found<br />
fructose<br />
fructose<br />
fructose<br />
Part No. 07110095/07110091<br />
CHROMATOGRAPHIC CONDITIONS<br />
Column: Reduced-activity 3 μm C18 column (83 mm x 4.6 mm i.d., 3 μm)<br />
Detection: UV absorbance at 265/285 nm<br />
Mobile Phase: 92% methanol/water<br />
Flow Rate: 1.5 mL/min. at 35 °C<br />
Sample: Animal feed premix<br />
Part No.<br />
N9303394<br />
3<br />
sorbitol<br />
mg/g<br />
1. Vitamin A Acetate 4.50<br />
2. Vitamin D 3 0.10<br />
3. Folic Acid 0.3 65.20<br />
4<br />
4<br />
Cartridge Column Applications Liquid Chromatography<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
279
Cartridge Column Applications<br />
Food Applications<br />
Liquid Chromatography Cartridge Column Applications<br />
Olive Oil Triglycerides<br />
0 4 8 0 4 8 12<br />
MINUTES<br />
CHROMATOGRAPHIC CONDITIONS<br />
Column: Two PerkinElmer Pecosphere 3 x 8 C18 columns<br />
connected in series (83 x 4.6 mm i.d., 3 μm)<br />
Detection: Refractive Index<br />
Mobile Phase: Acetone/Acetonitrile (70:30)<br />
Flow Rate: 2.5 mL/min.<br />
Part No. 02580166<br />
Organic Acids in Fruit Juice<br />
Absorbance (210 nm)<br />
Standards<br />
Trilinolenin<br />
Tripalmitolein<br />
Orange<br />
Juice<br />
Cranberry<br />
Cocktail<br />
Standards<br />
Trilinolein<br />
Triolean<br />
(000)<br />
oxalic<br />
quinic<br />
oxalic<br />
oxalic<br />
tartaric<br />
quinic<br />
malic<br />
CHROMATOGRAPHIC CONDITIONS<br />
Column: Spheri-5 RP-18 (220 x 4.6 mm, 5 μm)<br />
Detection: UV at 210 nm<br />
Mobile Phase: 25 mM KH 2 PO 4 at pH 2.4, purge with 30%<br />
ACN for 1 min. then equilibrate for 10 min.<br />
Flow Rate: 1.5 mL/min. at room temperature, pressure 2,400 psi<br />
Sample: 5 μL of beverage sample diluted 1:4 in mobile phase<br />
Part No. 07110017<br />
ascorbic<br />
quinic<br />
malic<br />
shikimic<br />
ascorbic<br />
LPL<br />
malic<br />
lactic shikimic<br />
acetic<br />
LPO<br />
LOL<br />
LOO<br />
OOO<br />
POO<br />
POP<br />
PPP<br />
SOO<br />
SPO<br />
citric<br />
citric<br />
citric<br />
000. Triolean<br />
L. Linoleic Acid<br />
P. Palmitic Acid<br />
S. Stearic Acid<br />
succinic<br />
1.0 2.0 3.0 4.0 5.0 6.0<br />
MINUTES<br />
UV ABSORBANCE<br />
Sweeteners and Additives in Beverages<br />
Peak Identification<br />
1. Matrix<br />
2. Saccharin<br />
3. Caffeine<br />
4. Aspartame<br />
5. Vanillin<br />
6. Sodium Benzoate<br />
CHROMATOGRAPHIC CONDITIONS<br />
Column: Pecosphere 5 x 15 C18 (150 x 4.6 mm i.d., 5 μm)<br />
Detection: UV at 254 nm<br />
Mobile Phase: 45% A in B A: Methanol B: Water with 0.7 g m/L hexane<br />
sulfonic acid & H 3 PO 4 to pH 2.1<br />
Flow Rate: 1.5 mL/min.<br />
Sample: 5 μL injection of carbonated beverage product<br />
Part No. 02580169<br />
Water-Soluble Vitamins in Animal Feed Premix<br />
295 nm<br />
275 nm<br />
1<br />
2<br />
3<br />
3<br />
Standards<br />
0 5 10<br />
MINUTES<br />
CHROMATOGRAPHIC CONDITIONS<br />
Column: PerkinElmer Reduced-activity 3 μm C8 column<br />
(83 mm x 4.6 mm i.d.)<br />
Detection: UV absorbance at 275 nm<br />
Mobile Phase: 15% methanol, 85% [10 mM hexanesulfonate (Sigma),<br />
1% acetic acid, 0.13% triethylamine in water]<br />
Flow Rate: 1.5 mL/min. at 35 °C<br />
Sample: Animal feed premix<br />
Part No. 02580192<br />
4<br />
1. Vitamin C<br />
2. Niacin<br />
5<br />
Vitamin Premix Found mg/g<br />
3. Niacinamide 7.2<br />
5. Thiamine 2.3<br />
6. Folic Acid 0.3<br />
7. Riboflavin 1.7<br />
5<br />
6<br />
6<br />
1<br />
2<br />
3<br />
0 MINUTES 5<br />
4<br />
5<br />
3. Niacinamide<br />
4. Pyridoxine<br />
5. Thiamine<br />
6. Folic Acid<br />
7. Riboflavin<br />
7<br />
7<br />
6<br />
280
Cartridge Column Applications<br />
Industrial Applications<br />
Epoxy Resin<br />
0 10 20 30<br />
Minutes<br />
CHROMATOGRAPHIC CONDITIONS<br />
Column: Pecosphere 3 C18 (83 x 4.6 mm, 3 μm)<br />
Detection: UV at 230 nm<br />
Mobile Phase: Linear gradient of 40% acetonitrile/water<br />
to 100% acetonitrile in 30 min.<br />
Flow Rate: 2.5 mL/min.<br />
Pressure: 4,300 psi (30 MPa)<br />
Temperature: Ambient<br />
Inj. Volume: 6 μL<br />
Hexachlorophene<br />
Peak Identification<br />
1. Unknown<br />
2. Tri-Chlorophenol<br />
3. Unknown<br />
4. Mixed Bis-Pheno<br />
5. Hexachlorophene<br />
6. Unknown<br />
7. Unknown<br />
8. 8-Chloro-Trimer<br />
9. 9-Chloro-Trimer<br />
CHROMATOGRAPHIC CONDITIONS<br />
Column: Pecosphere 3 C18 (83 x 4.6 mm, 3 μm)<br />
Detection: UV at 300 nm<br />
Mobile Phase: A: CH3CN<br />
B: 1% CH 3 COONH 4 in MeOH/H 2 0 (77:23) Concave<br />
gradient from 0.1% A to 40% A in 9 min.<br />
Flow Rate: 1.8 mL/min.<br />
Pressure: 4,300 psi (30 MPa)<br />
Temperature: Ambient<br />
Inj. Volume: 20 μL<br />
Polystyrene Additives<br />
Peak Identification<br />
1. Acetophenone<br />
2. Cumyl Alcohol<br />
3. Methyl Styrene<br />
4. Santonox<br />
5. Dicumyl Peroxide<br />
Part No. 02580166 Part No. 02580169<br />
Inj.<br />
1<br />
2 3<br />
4<br />
5<br />
6<br />
0 5 10 15<br />
Minutes<br />
7<br />
CHROMATOGRAPHIC CONDITIONS<br />
Column: Pecosphere 5 C18 (150 x 4.6 mm, 5 μm)<br />
Detection: UV at 254 nm<br />
Mobile Phase: Linear gradient of 25% acetonitrile/water<br />
to 100% acetonitrile in 10 min.<br />
Flow Rate: 3.0 mL/min.<br />
Pressure: 3,200 psi (8 MPa)<br />
Temperature: Ambient<br />
Inj. Volume: 6 μL<br />
Short-chain Fatty Acids<br />
Peak Identification<br />
1. Formic Acid<br />
2. Acetic Acid<br />
3. Propionic Acid<br />
4. Butyric Acid<br />
CHROMATOGRAPHIC CONDITIONS<br />
Column: Pecosphere 5 C18 (150 x 4.6 mm, 5 μm)<br />
Detection: UV at 220 nm<br />
Mobile Phase: 10% CH 3 CN in water (pH 2.0)<br />
Flow Rate: 2.0 mL/min.<br />
Pressure: 2,600 psi (18 MPa)<br />
Temperature: Ambient<br />
Inj. Volume: 10 μL<br />
Part No. 02580166 Part No. 02580169<br />
8<br />
9<br />
Inj.<br />
1 2 3 4<br />
0 2 4 6 8 10<br />
Minutes<br />
1<br />
2<br />
3<br />
0 1 2 3<br />
Minutes<br />
5<br />
4<br />
Cartridge Column Applications Liquid Chromatography<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
281
Cartridge Column Applications<br />
Pharmaceutical Applications<br />
Liquid Chromatography Cartridge Column Applications<br />
Analgesic/Anti-Inflammatory<br />
Peak Identification<br />
1. Acetaminophen<br />
2. Naproxen<br />
3. Indomethacin<br />
4. Phenylbutazone<br />
5. Meclolenamate<br />
1<br />
0 10<br />
MINUTES<br />
CHROMATOGRAPHIC CONDITIONS<br />
Column: Brownlee RP-8 Spheri-5 (220 x 2.1 mm)<br />
Detection: UV at 200 nm<br />
Mobile Phase: A: 0.08% Diethylamine 0.08% Phosphoric Acid<br />
90% Acetonitrile<br />
B: 0.08% Diethylamine 0.09% Phosphoric Acid pH 2.3<br />
Gradient: 5% A for 2 min.; 5% – 100% A in 15 min.; 100% A for 5 min.<br />
Flow Rate: 0.5 mL/min.<br />
Temperature: 50 °C<br />
Part No. 07110006<br />
Analgesics in Tablets<br />
Peak Identification<br />
1. Acetaminophen<br />
2. Caffeine<br />
3. Salicylamide<br />
4. Acetylsalicylic Acid<br />
CHROMATOGRAPHIC CONDITIONS<br />
Column: Pecosphere 3 x 8 C18 (33 x 4.6 mm i.d.)<br />
Detection: UV at 250 nm<br />
Mobile Phase: 15% CH 3 CN in 0.1% H 3 PO 4<br />
Flow Rate: 2.0 mL/min.<br />
Inj. Volume:1 μL of tablet extract<br />
Part No. 02580166<br />
1<br />
2<br />
3<br />
2<br />
4<br />
3<br />
0 1 2<br />
MINUTES<br />
4 5<br />
Antihistamines<br />
Peak Identification<br />
1. Chlorpheniramine<br />
2. Diphenhydramine<br />
3. Hydroxyzine<br />
4. Meclizine<br />
0 10<br />
MINUTES<br />
CHROMATOGRAPHIC CONDITIONS<br />
Column: Brownlee RP-8 Spheri-5 (220 x 2.1 mm)<br />
Detection: UV at 200 nm<br />
Mobile Phase: A: 0.08% Diethylamine 0.08% Phosphoric Acid<br />
90% Acetonitrile<br />
B: 0.08% Diethylamine 0.09% Phosphoric Acid pH 2.3<br />
Gradient: 5% A for 2 min.; 5% – 100% A in 15 min.; 100% A for 5 min.<br />
Flow Rate: 0.5 mL/min.<br />
Temperature: 50 °C<br />
Part No. 07110006<br />
Benzadiazepines<br />
Peak Identification<br />
1. Norchlordiazepoxide<br />
2. Chlorodiazepoxide<br />
3. Oxazepam<br />
4. Nordiazepam<br />
5. Desalkyiflurazepam<br />
6. Diazepam<br />
7. Flurazepam<br />
8. Prazepam<br />
0 10<br />
MINUTES<br />
CHROMATOGRAPHIC CONDITIONS<br />
Column: Brownlee RP-8 Spheri-5 (220 x 2.1 mm)<br />
Detection: UV at 200 nm<br />
Mobile Phase: A: 0.08% Diethylamine 0.08% Phosphoric Acid<br />
90% Acetonitrile<br />
B: 0.08% Diethylamine 0.09% Phosphoric Acid pH 2.3<br />
Gradient: 5% A for 2 min.; 5% – 100% A in 15 min.; 100% A for 5 min.<br />
Flow Rate: 0.5 mL/min.<br />
Temperature: 50 °C<br />
Part No. 07110006<br />
1<br />
1<br />
2<br />
2<br />
3<br />
3<br />
4 6<br />
5<br />
7<br />
8<br />
4<br />
282
Cartridge Column Applications<br />
Pharmaceutical Applications<br />
mAU (212 nm)<br />
Carbamazepine in Serum<br />
Clinical Sample<br />
Standard<br />
O<br />
0 2 4 6<br />
MINUTES<br />
CHROMATOGRAPHIC CONDITIONS<br />
Column: Validated C18 (100 x 4.6 mm i.d.)<br />
Detection: 212 nm<br />
Mobile Phase: 55% MeOH/H 2 O<br />
Flow Rate: 1.0 mL/min.<br />
Sample: 2 μL of standard at 10 ng/μL, 2 μL of clinical serum extract<br />
Part No. 00402241<br />
Cardiac Drugs<br />
Peak Identification<br />
N<br />
CONH 2<br />
1. Procainamide<br />
2. Acetylprocainamide<br />
3. Nadolol<br />
4. Lidocaine<br />
5. Disopyramide<br />
6. Propranolol<br />
7. Nifedipine<br />
CBZE<br />
CHROMATOGRAPHIC CONDITIONS<br />
Column: RP-8 Spheri-5 (220 x 2.1 mm)<br />
Detection: UV at 200 nm<br />
Mobile Phase: A: 0.08% Diethylamine 0.08%<br />
Phosphoric Acid 90% Acetonitrile<br />
B: 0.08% Diethylamine 0.09%<br />
Phosphoric Acid pH 2.3<br />
Gradient: 5% A for 2 min.; 5% – 100% A in 15 min.; 100% A for 5 min.<br />
Flow Rate: 0.5 mL/min.<br />
Temperature: 50 °C<br />
Part No. 07110006<br />
1<br />
0 10<br />
MINUTES<br />
2<br />
3<br />
CBZ<br />
4<br />
N<br />
CONH 2<br />
CHA (int. std.)<br />
5<br />
6<br />
7<br />
N<br />
CONH 2<br />
Chlorthalidone HPLC Assay<br />
ABSORBANCE (235 nm)<br />
0.005 AU<br />
Impurity<br />
Chlorthalidone<br />
OH<br />
NH<br />
CL<br />
O SO 2 NH 2<br />
Chlorthalidone<br />
0 1 2 3<br />
MINUTES<br />
CHROMATOGRAPHIC CONDITIONS<br />
Column: Reduced activity C18 (33 x 4.6 mm i.d.)<br />
Detection: UV at 235 nm<br />
Mobile Phase: MeOH:H 2 O:HOAc (34:65:1)<br />
Flow Rate: 1.5 mL/min..<br />
Temperature: 30 °C<br />
Part No. 02580195<br />
Estrogenic Steroids<br />
Peak Identification<br />
1. Estriol<br />
2. ß-Estradiol<br />
3. α-Equilenin<br />
4. Equilin<br />
5. Estrone<br />
O<br />
CO 2 H<br />
CL<br />
CCA SO 2 NH 2<br />
CCA<br />
CBSA<br />
OCH 3<br />
NH<br />
O<br />
CBSA<br />
CHROMATOGRAPHIC CONDITIONS<br />
Column: Pecosphere-3CR C18 (4.6 x 83 mm) coupled/<br />
a Pecosphere-3 x 3CR C18 (33 x 4.6 mm)<br />
Detection: UV at 280 nm<br />
Mobile Phase: 33/67 v/v ACN/(0.5 M Phosphate Buffer<br />
Monobasic, 0.1% TEA adjusted to pH 4)<br />
Inj. Volume: 10 μL<br />
Part No. 02580194/02580195<br />
1<br />
2<br />
10 Minutes<br />
3<br />
4<br />
5<br />
CL<br />
SO 2 NH 2<br />
Cartridge Column Applications Liquid Chromatography<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
283
Cartridge Column Applications<br />
Pharmaceutical Applications<br />
Liquid Chromatography Cartridge Column Applications<br />
Parabens in Hand Cream<br />
Peak Identification<br />
1. Methylparaben<br />
2. Ethylparaben<br />
3. Propylparaben<br />
4. Butylparaben<br />
CHROMATOGRAPHIC CONDITIONS<br />
Column: Pecosphere 3 x 3CR C18 (33 x 4.6 mm)<br />
Detection: UV at 254 nm<br />
Mobile Phase: 50/50 v/v Methanol/H 2 0<br />
Flow Rate: 3 mL/min.<br />
Inj. Volume: 10 μL<br />
Part No. 02580195<br />
Phenothiazines<br />
Peak Identification<br />
1. Mesoridazine<br />
2. Promazine<br />
3. Thiothixene<br />
4. Chlorpromazine<br />
5. Trifluoperazine<br />
6. Thioridazine<br />
1<br />
3<br />
0 30<br />
Seconds<br />
0 10<br />
MINUTES<br />
Handcream<br />
Standards<br />
1<br />
2<br />
3<br />
4<br />
0 30<br />
Seconds<br />
CHROMATOGRAPHIC CONDITIONS<br />
Column: Brownlee RP-8 Spheri-5 (220 x 2.1 mm)<br />
Detection: UV at 200 nm<br />
Mobile Phase: A: 0.08% Diethylamine 0.08% Phosphoric Acid 90%<br />
Acetonitrile<br />
B: 0.08% Diethylamine 0.09% Phosphoric Acid pH 2.3<br />
Gradient: 5% A for 2 min.; 5% – 100% A in 15 min.; 100% A for 5 min.<br />
Flow Rate: 0.5 mL/min.<br />
Temperature: 50 °C<br />
Part No. 07110006<br />
1<br />
2<br />
3<br />
4<br />
5<br />
6<br />
Intensity, cps<br />
Prednisone in Tablet Preparations<br />
Peak Identification<br />
1. Acetanilide<br />
2. Prednisone<br />
2.5 mg<br />
Deltasone<br />
Tablet<br />
CHROMATOGRAPHIC CONDITIONS<br />
Column: Pecosphere 3 x 8 C18 (83 x 4.6 mm i.d.)<br />
Detection: UV at 254 nm<br />
Mobile Phase: 50/50 v/v methanol/water<br />
Flow Rate: 2 mL/min.<br />
Inj. Volume:10 μL<br />
Part No. 02580166<br />
1<br />
2<br />
Standards<br />
45 SECONDS 45 SECONDS<br />
The LC/MS Identification and Quantitation of<br />
Quinolone Antibiotic Degradation Products<br />
Photolyte 2 MS<br />
308.2<br />
290.2<br />
300 m/z, amu<br />
Lomefloxacin MS<br />
352.2<br />
308.2<br />
300 m/z, amu<br />
1 2 3 4 5 6 7<br />
Time, Minutes<br />
CHROMATOGRAPHIC CONDITIONS<br />
Column: Reduced Activity C18 (33 x 4.6 mm, 3-μm)<br />
Detection: LC/MS with IonSpray (pneumatically assisted electrospray)<br />
Mobile Phase: Solvent A: 95% water, 0.1% formic acid, 5% MeOH<br />
Solvent B: 95% MeOH, 0.1% formic acid, 5% water<br />
0-12% B (convex, program 4) in 5 min., hold 5 min.<br />
Flow Rate: 1 mL/min. – split 65 mL/min. to MS, the rest to UV detector<br />
Sample: A partially degraded sample of Lomefloxacin (25 μg/mL) after<br />
irradiation for 10 min. Note photolyte 2 is only at ~0.5% level.<br />
Part No. 02580195<br />
Extracted Ion Chromatogram<br />
m/z = 332<br />
4.51<br />
m/z = 294<br />
4.66<br />
m/z = 308<br />
5.22<br />
4 5 6 7<br />
Total Ion Chromatogram<br />
Photolyte 3<br />
Photolyte 1<br />
Photolyte 2<br />
4.56<br />
4.66 5.22<br />
Lomefloxacin<br />
1<br />
2<br />
m/z = 352<br />
m/z = 308<br />
284
Cartridge Columns<br />
Brownlee CHOICE Columns for LC/MS<br />
Columns for LC/MS<br />
The matrix below illustrates the wide variety of column<br />
dimensions for the different chromatographic needs. Shorter<br />
length columns allow for faster separations. Smaller internal<br />
diameters (i.d.) offer higher sensitivity for smaller sample<br />
concentration. A longer column will be better suited to<br />
more complicated mixtures or where resolution may be<br />
difficult. If sample size is a concern; use a column with a<br />
smaller internal diameter; 2.1 or 3.2 mm, since this will<br />
provide greater sensitivity.<br />
There are four levels of efficiency/capacity to choose from:<br />
Type of Spectrometer User Needs Column Recommendation<br />
Triple or Single quad Moderate efficiency 20 x 3.2, 3 μm<br />
Low capacity<br />
High throughput<br />
Single quad Better efficiency 30 x 2.1, 3 μm<br />
Medium capacity 30 x 4.6, 5 μm<br />
Triple quad Best efficiency 50 x 3.2, 3 μm<br />
Medium capacity 50 x 3.2, 5 μm<br />
Triple quad High efficiency 50 x 4.6, 5 μm<br />
High capacity<br />
CHOICE Columns<br />
The CHOICE columns provide the speed and efficiency<br />
appropriate for LC/MS. Each column’s separation<br />
requirements vary depending on the system, sample,<br />
and mass spectrometer.<br />
PFPP for Separating Basic Drugs for LC/MS<br />
Penta Fluoro Phenyl Propyl (PFPP) phase is ideal for basic<br />
drug separation prior to mass spectrometry. This bonded<br />
phase has been shown to efficiently separate basic drugs<br />
in a 90% Acetonitrile/water mobile phase, eliminating the<br />
interference of ion-pairing reagents and ion-suppressing<br />
agents normally used for these separations on C18. 1, 2<br />
References:<br />
1<br />
S.R. Needham, et.al. Rapid Commun. in Mass Spectrom.,<br />
13, 2231-2236 (1999)<br />
2<br />
S.R. Needham, et.al. J. Chromatogr, A 869 (2000) 159-170<br />
Particle Pore Surface % End<br />
Description Size Diameter Area (M 2 /G) Carbon Cap<br />
CHOICE C18, 3 μ 3 μm 100 Å 350 12% Yes<br />
CHOICE C8, 3 μ 3 μm 100 Å 350 7% Yes<br />
CHOICE C18, 5 μ 5 μm 100 Å 350 12% Yes<br />
CHOICE PFPP, 5 μ 5 μm 100 Å 320 5% Yes<br />
30x2.1 mm i.d.** 30x4.6 mm i.d.** 50x3.2 mm i.d.* 50x4.6 mm i.d.*<br />
1 per package 1 per package 1 per package 1 per package<br />
Description Part No. Each (€) Part No. Each (€) Part No. Each (€) Part No. Each (€)<br />
CHOICE C18, 3 μm N2580003 421<br />
CHOICE C8, 3 μm N2580012 408 N2580013 421<br />
CHOICE C18, 5 μm N2580020 408 N2580022 421 N2580021 421<br />
CHOICE PFPP, 5 μm N2580042 408<br />
* Requires Holder (N2580030)<br />
** Requires Holder (07150013)<br />
Note: See page 293 for additional MPLC holders.<br />
Specifications<br />
Cartridge Columns Liquid Chromatography<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
285
Cartridge Columns<br />
Brownlee MPLC Columns<br />
Ion Exchange<br />
Note: For additional Ion Exchange Column lengths, please see page 287.<br />
30 mm x 4.6 mm i.d.* 30 mm x 2.1 mm i.d.* 100 mm x 4.6 mm i.d.**<br />
2 per package 2 per package 1 per package<br />
Description Part No. Each (€) Part No. Each (€) Part No. Each (€)<br />
Liquid Chromatography Cartridge Columns<br />
AX-300, Aquapore ® 07110073 381 07110074 318 07110075 509<br />
7 μm, 300 Å, weak anion<br />
Polypore ® CA 07110091 381 07110093 625<br />
10 μm, polymeric, calcium form<br />
Polypore H 07110085 611 07110087 1185<br />
10 μm, polymeric, hydrogen form<br />
Polar Phase<br />
Note: For additional Polar Phase Column lengths, please see page 287.<br />
Amino, Spheri-5 ® 07110037 165 07110039 292<br />
Aminopropyl, 5 μm, 80 Å<br />
Cyano, Spheri-5 07110043 165 07110045 292<br />
Cyanopropyl, 5 μm, 80 Å<br />
Silica, Spheri-5 07110031 165 07110032 126 07110033 381<br />
5 μm, 80 Å<br />
Silica, Spheri-10 07110145 152<br />
10 μm, 80 Å<br />
Reversed Phase<br />
Note: For additional Reversed Phase Column lengths, please see page 287.<br />
BU-300, Aquapore Butyl C-4, 07110061 190 07110062 165<br />
7 μm, 300 Å<br />
Cyano, Spheri-5 07110043 165 07110045 292<br />
Cyanopropyl, 5 μm, 80 Å<br />
OD-300, Aquapore ODS 07110235 165 07110234 165 07110232 292<br />
C-18, 7 μm, 300 Å<br />
ODS, Spheri-5 07110019 165 07110020 114 07110021 356<br />
C-18, polyfunctional, 5 μm, 80 Å,<br />
Phenyl, Spheri-5 07110025 190 07110027 332<br />
Phenyl, 5 μm, 80 Å<br />
RP-8, Spheri-5 07110001 165 07110002 126 07110003 356<br />
C-8, monofunctional, 5 μm, 80 Å<br />
RP-8, Spheri-10 07110121 152 07110123 254<br />
C-8, monofunctional, 10 μm, 80 Å<br />
RP-18, Spheri-5 07110013 165 07110014 165 07110015 228<br />
C-18, monofunctional, 5 μm, 80 Å<br />
RP-18, Spheri-10 07110115 165 07110117 420<br />
C-18, monofunctional, 10 μm, 80 Å<br />
RP-300, Aquapore Octyl C-8, 07110055 190 07110056 228 07110057 356<br />
7 μm, 300 Å<br />
* Requires Holder (07150013)<br />
** Requires Holder (07150014)<br />
286
Cartridge Columns<br />
Brownlee MPLC Columns<br />
Ion Exchange<br />
Note: For additional Ion Exchange Column lengths, please see page 286.<br />
100 mm x 2.1 mm i.d.** 220 mm x 4.6 mm i.d.*** 220 mm x 2.1 mm i.d.***<br />
1 per package 1 per package 1 per package<br />
Description Part No. Each (€) Part No. Each (€) Part No. Each (€)<br />
AX-300, Aquapore ® 07110077 802<br />
7 μm, 300 Å, weak anion<br />
Polypore ® CA 07110095 955<br />
10 μm, polymeric, calcium form<br />
Polypore H 07110089 1529<br />
10 μm, polymeric, hydrogen form<br />
Polar Phase<br />
Note: For additional Polar Phase Column lengths, please see page 286.<br />
Amino, Spheri-5 ® 07110041 381<br />
Aminopropyl, 5 μm, 80 Å<br />
Cyano, Spheri-5 07110047 483<br />
Cyanopropyl, 5 μm, 80 Å<br />
Silica, Spheri-5 07110035 483<br />
5 μm, 80 Å<br />
Silica, Spheri-10<br />
10 μm, 80 Å<br />
Reversed Phase<br />
Note: For additional Reversed Phase Column lengths, please see page 286.<br />
BU-300, Aquapore Butyl C-4, 07110064 356<br />
7 μm, 300 Å<br />
Cyano, Spheri-5 07110047 483<br />
Cyanopropyl, 5 μm, 80 Å<br />
OD-300, Aquapore ODS 07110233 318 07110231 356 07110236 356<br />
C-18, 7 μm, 300 Å<br />
ODS, Spheri-5 07110022 254 07110023 509 07110024 420<br />
C-18, polyfunctional, 5 μm, 80 Å,<br />
Phenyl, Spheri-5 07110029 547<br />
Phenyl, 5 μm, 80 Å<br />
RP-8, Spheri-5 07110004 318 07110005 547 07110006 381<br />
C-8, monofunctional, 5 μm, 80 Å<br />
RP-8, Spheri-10<br />
C-8, monofunctional, 10 μm, 80 Å<br />
RP-18, Spheri-5 07110016 292 07110017 547 07110018 318<br />
C-18, monofunctional, 5 μm, 80 Å<br />
RP-18, Spheri-10 07110119 381<br />
C-18, monofunctional, 10 μm, 80 Å<br />
RP-300, Aquapore Octyl C-8, 07110058 292 07110059 611 07110060 381<br />
7 μm, 300 Å<br />
** Requires Holder (07150014)<br />
*** Requires Holder (07150015)<br />
Cartridge Columns Liquid Chromatography<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
287
Cartridge Columns<br />
Brownlee Peco Fast LC Columns<br />
Liquid Chromatography Cartridge Columns<br />
Fast HPLC with 3x3 TM Peco Columns<br />
PerkinElmer pioneered the development of Fast HPLC and<br />
introduced the popular 3x3 Columns (33 x 4.6 mm) in the<br />
80s. The 3x3 Column is capable of very rapid analysis, as<br />
short as one to two minutes. These columns are available in<br />
economical packs of five. The 83 mm long 3x8 Column with<br />
>10,000 plates can separate many complex mixtures in less<br />
than 10 minutes.<br />
PerkinElmer’s Peco cartridges (including Fast HPLC) are<br />
available with MPLC ® holders. Three cartridge lengths<br />
(33, 83, and 150 mm) are available in 4.6 mm i.d.<br />
Additionally, the Peco cartridges are still compatible with<br />
the “old-style” Peco cartridge holders (wrench-tightened).<br />
Three Peco silica-based supports are available.<br />
Peco MPLC holders (83 and 33 mm).<br />
Pecosphere TM is a small-pore, extremely rugged<br />
(80 Å, 3, 5, and 10 μm, C18 or silica) sorbent for<br />
HPLC of small molecules.<br />
Peco HCODS is a wide-pore (300 Å, 5 μm, polyfunctional<br />
C18) sorbent for separation of proteins and peptides.<br />
Reduced Activity is a small-pore, base-deactivated<br />
(100 Å, 3, and 5 μm, C8 or C18) sorbent developed<br />
for HPLC of basic analytes and pharmaceuticals. The<br />
proprietary bonding chemistry increases its resistance<br />
to acidic mobile phase.<br />
SCAVENGER COLUMNS are small precolumns<br />
(33 x 4.6 mm i.d.) packed with 10 μm, C18 or silica<br />
materials. The scavenger is placed before the injector<br />
to protect the analytical column from mobile phase<br />
contaminant's. Its use is mandatory for Fast HPLC to<br />
prolong column life. It is available as a pack of five<br />
and requires the Peco MPLC holder.<br />
Specifications<br />
UV ABSORBANCE<br />
Analysis of Water-Soluble Vitamins<br />
in Multivitamin Tablets<br />
295 nm<br />
Standards<br />
275 nm<br />
1<br />
2<br />
3<br />
Multivitamin Capsule<br />
1<br />
3<br />
4<br />
4<br />
Centrum TM Tablet<br />
1<br />
3<br />
4<br />
CHROMATOGRAPHIC CONDITIONS<br />
Column: Reduced-activity 3 μm C8 column<br />
(83 mm x 4.6 mm i.d.)<br />
Found (mg)<br />
1. 176.00<br />
3. 26.00<br />
4. 2.23<br />
5. 11.30<br />
6. 1.06<br />
7. 5.38<br />
Found (mg)<br />
1. 74.00<br />
3. 18.50<br />
4. 2.51<br />
5. 1.45<br />
6. 0.42<br />
7. 1.62<br />
Detection: UV Absorbance at 275 nm<br />
Mobile Phase: 15% Methanol, 85% [10 mM Hexanesulfonate,<br />
1% Acetic Acid, 0.13% Triethylamine in Water]<br />
Flow Rate: 1.5 mL/min. at 35 °C<br />
Sample: 5 μL of Vitamin Tablet Extracts<br />
5<br />
5<br />
5<br />
0.0 5.0 10.0<br />
TIME (MIN.)<br />
Part No. 02580192<br />
1. Vitamin C<br />
2. Niacin<br />
3. Niacinamide<br />
4. Pyridoxine<br />
Particle Pore Surface % End<br />
Product Functionality Size μm Diameter Å Area (M 2 /G) Carbon Cap<br />
Pecosphere 3 C18 C18, monofunctional 3 80 170 11 Yes<br />
Pecosphere 5 C18 C18, monofunctional 5 80 170 11 Yes<br />
Reduced Activity 3 C18 C18, monofunctional 3 80 200 12 Yes<br />
Reduced Activity 3 C8 C8, monofunctional 3 80 200 5 Yes<br />
Reduced Activity 5 C18 C18, monofunctional 5 80 200 12 Yes<br />
Reduced Activity 5 C8 C8, monofunctional 5 80 200 5 Yes<br />
Peco HCODS C18, polyfunctional 5 300 90 9 No<br />
C18 Scavenger C18, monofunctional 10 80 170 11 Yes<br />
6<br />
6<br />
6<br />
7<br />
7<br />
7<br />
5. Thiamine<br />
6. Folic Acid<br />
7. Riboflavin<br />
288
Cartridge Columns<br />
Brownlee Peco Fast LC Columns<br />
Normal Phase<br />
33 x 4.6 mm i.d.* 83 x 4.6 mm i.d.** 150 x 4.6 mm i.d.***<br />
5 per package 1 per package 1 per package<br />
(requires holder 07150028) (requires holder 07150029) (requires holder 07150030)<br />
Description Part No. Each (€) Part No. Each (€) Part No. Each (€)<br />
Pecosphere 3 Silica 02580167 281<br />
Reversed Phase<br />
Monofunctional; Pore Diameter 80 Å<br />
Pecosphere 3 C18, 3 μm 02580164 555 02580166 287<br />
Pecosphere 5 C18, 5 μm 02580169 332<br />
Pecosphere 3CR C8, Base Deactivated, 3 μm 02580191 619 02580192 274<br />
Pecosphere 3CR C18, Base Deactivated, 3 μm 02580195 778 02580194 274<br />
Reduced Activity 5 C18, 5 μm N9303396 357<br />
Reduced Activity 5 C8, 5 μm 02580168 299<br />
Peco HCODS C18, Polyfunctional, 5 μm, 300 Å 02580213 242<br />
Scavenger Columns<br />
Silica Scavenger, 10 μm 02580203 510<br />
C18 Scavenger, Monofunctional, 10 μm, 80 Å 02580202 593<br />
Van Deemter’s Curves<br />
HETP (μm)<br />
60<br />
40<br />
20<br />
5 μm<br />
0<br />
0 2 4 6 8<br />
FLOW RATE (mL/min)<br />
10 μm<br />
3 μm<br />
Van Deemter’s curves showing column plate height vs. flow rate for 3,<br />
5, and 10 μm particle columns. The 3 μm particle is preferred for Fast<br />
LC because of its superior performance and higher optimum flow rate.<br />
Analysis of an Analgesic<br />
Tablet Using Fast LC<br />
Peak Identification<br />
1. Acetaminophen<br />
2. Caffeine<br />
3. Salicylamide<br />
4. Acetylsalicylic Acid<br />
0 1 2<br />
TIME (MIN.)<br />
CHROMATOGRAPHIC CONDITIONS<br />
Column: Pecosphere 3x3 C18 (33 x 4.6 mm)<br />
Detection: UV at 240 nm<br />
Mobile Phase: 15% CH 3 CN in H 2 0<br />
Flow Rate: 2.0 mL/min.<br />
Sample: 1 μL of the tablet extract<br />
Part No. 02580164<br />
1<br />
2<br />
3<br />
4<br />
Cartridge Columns Liquid Chromatography<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
289
Cartridge Columns<br />
Brownlee Preparative and VeloSep Columns<br />
Liquid Chromatography Cartridge Columns<br />
Brownlee Preparative Columns<br />
Preparative columns are 10 mm i.d. cartridges, packed with<br />
Aquapore ® 20 μm, 300 Å sorbents.<br />
Easy scale-up from the Aquapore analytical<br />
columns using similar bonded phase<br />
Available in 30, 100, and 250 mm cartridges<br />
The unique 100 and 250 mm cartridge design<br />
incorporates a moveable inlet plug and filter which<br />
compensates for changes in bed volume with use<br />
Typical sample capacity of the 250 mm cartridge<br />
is 50 mg to 1 g of material (depending on resolution and<br />
purity requirements). The typical flow rate is 4-10 mL/min.<br />
Save time with high-pressure<br />
preparative runs up to 3000 psi<br />
Achieve high performance with<br />
the 20 μm, 300 Å sorbents<br />
optimized for bioseparations<br />
Specifications<br />
Pore Diameter: 300 Å - Surface Area: 100 M 2 /G - End Cap: Yes<br />
Product Functionality % Carbon<br />
Aquapore Octyl Octyl (C8) 5<br />
Aquapore ODS Octadecyl (C18) 10<br />
Note: The Aquapore Preparative Sorbents are spherical 20 μm<br />
silica-based sorbents.<br />
Preparative Columns<br />
20 μm, 300 Å, 10 mm i.d.<br />
Description Part No. Each (€) Part No. Each (€)<br />
Aquapore Octyl 07110165* 700 07110166** 891<br />
Aquapore ODS 07110114* 675 07110163** 1121<br />
* 100 mm Cartridge (Requires holder 07150005)<br />
** 250 mm Cartridge (Requires holder 07150006)<br />
Brownlee VeloSep Columns<br />
VeloSep ® columns are 3.2 mm i.d. cartridges packed with<br />
3 μm reversed-phase support for high throughput analysis<br />
and reduced solvent consumption.<br />
Improve sensitivity and speed while cutting<br />
solvent consumption by half<br />
Packed with 3 μm C8 or C18 sorbents<br />
Available in 40 or 100 mm lengths<br />
Specifications<br />
Prep-10 Cartridges<br />
Pore Diameter: 100 Å - Surface Area: 170 M 2 /G - End Cap: Yes<br />
Product Functionality % Carbon<br />
RP-8, VeloSep Octyl (C8) 7<br />
RP-18, VeloSep Octadecyl (C18) 14<br />
VeloSep Columns<br />
3 μm, C18, 100 Å, 3.2 mm i.d.<br />
Description Part No. Each (€) Part No. Each (€)<br />
RP-8, VeloSep 07110189* 165 07110190** 318<br />
RP-18, VeloSep 07110191* 152 07110192** 254<br />
* 40 mm Cartridge, (pkg. 2), (Requires holder 07150013)<br />
** 100 mm Cartridge (Requires holder 07150014)<br />
Analysis of Penicillins<br />
VeloSep RP-18, 3 μm, 100 x 3.2 mm<br />
Purification of Synthetic Trityl-On Oligonucleotides<br />
Aquapore Octyl, 20 μm 250 x 10 mm<br />
ABSORBANCE mAU<br />
CHROMATOGRAPHIC CONDITIONS<br />
Conditions: Solvent A: 10 mM Sodium Phosphate pH 6.5<br />
Solvent B: 50% Isopropyl Alcohol in Water<br />
Gradient: 5-50% B in 10 min.<br />
Flow Rate: 0.5 mL/min.<br />
Temperature: 5 °C, 230 nm<br />
Part No. 07110192<br />
600<br />
500<br />
400<br />
300<br />
200<br />
100<br />
ABSORBANCE<br />
0<br />
0 5 10<br />
TIME (MIN.)<br />
2.859<br />
2.859<br />
2.029<br />
Amoxicillin<br />
Ampicillin<br />
4.018<br />
5.250<br />
5.250<br />
6.770<br />
7.184<br />
0.333<br />
8.926<br />
9.643<br />
10.117<br />
0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34<br />
TIME (MIN.)<br />
CHROMATOGRAPHIC CONDITIONS<br />
Conditions: Buffer A: 100 mM Triethylammonium Acetate pH 7.6<br />
Buffer B: 80% Acetonitrile in Buffer A<br />
Gradient: 10-45% B in 35 min.<br />
Sample: 0.25 μ Mole DNA material<br />
Flow Rate: 5.0 mL/min. Ambient. 260 nm<br />
Part No. 07110166<br />
Cloxicillin contaminant<br />
Penicillin G<br />
20.218<br />
23.474<br />
Piperacillin<br />
Cloxicillin<br />
26.736<br />
290
Cartridge Columns<br />
Brownlee Validated MPLC Columns<br />
Brownlee Validated Columns<br />
Brownlee Validated Sorbent<br />
The Brownlee Validated Sorbent is derived from a neutral<br />
“Type B” silica with inherent low silanophilic activity. Each<br />
sorbent lot is tested to meet stringent specifications for the<br />
separation of basic, neutral, and acidic test probes. Column<br />
lifetime studies and additional selectivity evaluations using<br />
real samples are also conducted. A high-temperature bonding<br />
technique is coupled with an exhaustive end-capping<br />
procedure to ensure maximum coverage of the silica surface.<br />
A proprietary treatment step is used to further eliminate<br />
any trace residual metals in the silica that create active<br />
adsorptive sites. The result is a highly deactivated column<br />
which yields excellent peak shape for difficult basic analytes,<br />
pharmaceuticals, and small peptides.<br />
Important Features of Validated Columns<br />
Convenient cartridge design<br />
Guaranteed batch-to-batch reproducibility<br />
Test Chromatogram and Certification of Compliance shipped<br />
with each column (except for 30 mm and NewGuard ® )<br />
Packed with a 5 μm reduced activity monofunctional C18 sorbent<br />
Compatibility with acidic, neutral, and basic analytes<br />
Excellent column lifetime<br />
Available in 30, 100, 150, or 220 mm MPLC cartridges<br />
(2.1 mm and/or 4.6 mm i.d.)<br />
Select 100 mm cartridge for routine assays<br />
30 mm cartridge for screening or as a replaceable front end<br />
Use 2.1 mm i.d. cartridges to reduce solvent consumption<br />
Lot history tracking system<br />
Specifications<br />
Validated MPLC Columns<br />
Validated C18 (100 x 4.6 mm i.d.) 34% MeOH,<br />
65% water, 1% HOAc, 1 mL/min., 1650 psi,<br />
30 °C 10 μL of degraded chlorthalidone at 1 μg/μL<br />
ABSORBANCE mAU<br />
200<br />
180<br />
160<br />
140<br />
120<br />
100<br />
80<br />
60<br />
40<br />
20<br />
Pore Surface % End<br />
Product Functionality Diameter Area (M 2 /G) Carbon Cap<br />
Validated (5 μm) C18 monofunctional 100 Å 350 ± 10% 18% Yes<br />
Description Part No. Each (€)<br />
Validated C18, 220 x 4.6 mm (requires 220 mm holder 07150015) 00402243 514<br />
Validated C18, 150 x 4.6 mm (requires 150 mm holder 07150030) 00403058 636<br />
Validated C18, 100 x 4.6 mm (requires 100 mm holder 07150014) 00402241 445<br />
Validated C18,100 x 2.1 mm (requires 100 mm holder 07150014) 00402240 318<br />
Validated C18, 30 x 4.6 mm (requires 30 mm holder 07150013) 00402239 292<br />
Validated C18, NewGuard, 15 x 3.2 mm 00402237 165<br />
(requires NewGuard holder 07150001)<br />
100 mm NewGuard System Holder 07150016 318<br />
(For direct coupling of NewGuard and 100 mm cartridge)<br />
Union (For direct coupling of two cartridges) 07150018 152<br />
Note: See page 293 for additional MPLC holders.<br />
Impurity<br />
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15<br />
TIME (MIN.)<br />
Comparative test results of columns packed with three different silica<br />
lots for a USP assay of chlorthalidone. The chromatogram of a degraded<br />
bulk sample (1 mg/mL) shows the presence of an unidentified impurity,<br />
chlorthalidone, its hydrolysis product, 4'-chloro-3'-sulfamoyl-2-<br />
benzophenone carboxylic acid (CCA) and a degradation product,<br />
2-chloro-5- (1-methoxy-3-oxo-1-isoindoliny)-benzenesulfonamide (CBSA).<br />
Part No. 00402241<br />
Validated C18 (100 x 4.6 mm),<br />
75/25 MeOH/Water 1 mL/min.,<br />
30 °C, 230 nm detection<br />
Pyridine<br />
Uracil<br />
Chlorthalidone<br />
CCA<br />
Propyl<br />
Paraben<br />
0 TIME (MIN.) 4<br />
CBSA<br />
N, N-dimethylaniline<br />
Toluene<br />
Silica Lot 1<br />
Lot 2<br />
Lot 3<br />
Performance of Validated Column with basic,<br />
acidic, and neutral test probes.<br />
Part No. 00402241<br />
Cartridge Columns Liquid Chromatography<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
291
Cartridge Columns<br />
Guard Cartridge Columns and Accessories<br />
NewGuard Columns<br />
Standards Solutions<br />
Liquid Chromatography Cartridge Columns<br />
NewGuard cartridges are small guard cartridges (15 mm x 3.2<br />
mm i.d.) packed with 5 or 7 μm sorbents. NewGuard<br />
cartridges prolong column life by eliminating particulates,<br />
contaminant's, and strongly bound sample components.<br />
They act as replaceable, disposable heads of your analytical<br />
columns. There is negligible loss of efficiency and little effect<br />
on retention or resolution. NewGuards are available<br />
in a convenient 3-pack and can be coupled directly to any<br />
MPLC cartridge with a union (07150018).<br />
Prolong column life by 2 to 5 times<br />
Protect your column from particulates and strongly<br />
bound sample components<br />
Optimized dimensions to prevent loss of resolution<br />
Easy coupling to MPLC cartridges or conventional columns<br />
Finger-tight seal to 7000 psi using NewGuard holders<br />
Can be used for sample preconcentration<br />
(connected to sample injection loop)<br />
15 mm cartridge*, 3.2 mm i.d., 3 per pkg.<br />
Description Part No. Each (€)<br />
Amino, Aquapore ® Amino, 7 μm spherical 07110098 126<br />
Anion, Aquapore Anion, 7 μm spherical 07110102 152<br />
Cyano, Aquapore Cyano, 7 μm spherical 07110100 126<br />
Diol, Aquapore Diol, 7 μm spherical 07110105 153<br />
Phenyl, Aquapore Phenyl, 7 μm spherical 07110096 126<br />
RP-2, Aquapore Dimethyl, 7 μm spherical 07110086 126<br />
RP-4, Aquapore Butyl, 7 μm spherical 07110088 126<br />
RP-8, Aquapore Octyl, 7 μm spherical 07110090 126<br />
RP-18, Aquapore ODS, 7 μm spherical 07110092 126<br />
Silica, Aquapore Silica, 7 μm spherical 07110106 101<br />
Validated ® , C18, 5 μm spherical 00402237 165<br />
* Requires holder (07150001)<br />
Note: Actual bed length of NewGuard is about 13 mm<br />
Replacement Seals for MPLC and Prep-10 Holders<br />
Test Mix<br />
Description Part No. Each (€)<br />
Universal test mix for reversed-phase (5 mL/pkg.) 00890893 43<br />
Standards<br />
Description Part No. Each (€)<br />
HPLC SV Calibration Mix #5/610 PAH 00891542 114<br />
HPLC 610 Calibration Mix A 00891543 59<br />
HPLC 610 Calibration Mix B 00891544 59<br />
NewGuard cartridges directly coupled to a 220 mm MPLC<br />
cartridge and connected externally to a 250 mm conventional column.<br />
View of the NewGuard holder<br />
and a NewGuard 3/pack.<br />
Item Description Part No. Each (€)<br />
Prep-10 Inlet Seal One each (Prep-10 Seal Replacement Kit tools required) 07150012 37<br />
Prep-10 Outlet Seal One each (Prep-10 Seal Replacement Kit tools required) 07150026 24<br />
Seals for MPLC Holders Two 7000 psi seals (Seal Replacement Kit tools required) 07150024 37<br />
Seal Replacement Kit for MPLC Holders Tools and two 7000 psi seals 07150023 126<br />
292
Cartridge Columns<br />
Holders and Accessories for Cartridge Columns<br />
Product MPLC/Peco Family<br />
TM Holders<br />
The patented MPLC cartridge system ensures leak-free operation up to 7000 psi, with only finger-tightening. The<br />
high-pressure seal in each end assembly actually seals tighter as pressure increases. No wrenches are required, and<br />
there is no need to disconnect any tubing to your LC system when changing a cartridge. Each MPLC cartridge can<br />
be directly coupled to another using a union.<br />
Name Description Part No. Each (€)<br />
Universal Holder Kit Includes 100 and 220 mm holder bodies, 07150025 483<br />
2 end assemblies, 1 union, 1 NewGuard end assembly.<br />
NewGuard ® Holder Holds a single NewGuard cartridge or a single 20 mm 07150001 190<br />
CHOICE TM cartridge.<br />
30 mm Holder Holds a single MPLC and CHOICE 30 mm cartridge. 07150013 190<br />
33 mm Peco Holder Holds 33 mm Fast LC Peco cartridge only. 07150028 228<br />
50 mm Holder Holds a single 50 mm CHOICE cartridge only. N2580030 244<br />
83 mm Peco Holder Holds 83 mm Fast LC Peco cartridge only. 07150029 292<br />
100 mm Holder Holds a single MPLC 100 mm cartridge. 07150014 190<br />
150 mm Holder Holds a single MPLC 150 mm cartridge. 07150030 165<br />
220 mm Holder Holds a single MPLC 220 mm cartridge. 07150015 190<br />
250 mm Holder Holds a single MPLC 250 mm cartridge. 07150031 318<br />
100 mm NewGuard Holder for a NewGuard and a 100 mm coupled cartridge. 07150016 318<br />
System Holder<br />
220 mm NewGuard Holder for a NewGuard 07150017 318<br />
System Holder<br />
and a 220 mm coupled cartridge.<br />
130 mm MPLC Holder for a 30 and 100 mm coupled cartridge. 07150032 292<br />
System Holder<br />
Union For direct coupling of 2 cartridge holders. 07150018 152<br />
(Two holder bodies and 2 end assemblies also required.)<br />
NewGuard Upgrades a 30 mm holder to a NewGuard holder. 07150002 126<br />
End Assembly<br />
End Assembly Holder component. 07150019 75<br />
30 mm Holder Body Holder component. 07150020 37<br />
100 mm Holder Body Holder component. 07150021 45<br />
220 mm Holder Body Holder component. 07150022 63<br />
Prep-10 Cartridge Holders<br />
100 mm Prep-10 Holder Holds a single 100 mm Prep-10 cartridge. 07150005 356<br />
250 mm Prep-10 Holder Holds a single 250 mm Prep-10 cartridge. 07150006 445<br />
Cartridge Columns Liquid Chromatography<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
293
Conventional Columns<br />
Conventional Columns<br />
Brownlee Conventional Columns<br />
Conventional Brownlee Columns (non-cartridge) use standard<br />
compression end fittings compatible with all HPLC instrumentation.<br />
These columns do not require MPLC holders.<br />
■ End fittings compatible with HPLC systems from any vendor<br />
■ Use with NewGuard system (line connection) for even longer column life<br />
■ Each column is individually tested<br />
Conventional columns do not require MPLC holders.<br />
Brownlee Microbore HPLC Columns<br />
Microbore columns (1.0 mm i.d.) are ideal for the analysis of samples<br />
of limited availability (e.g., micropurification of picomole levels of<br />
proteins/peptides). Reducing the column diameter from the standard<br />
4.6 mm to 1.0 mm increases the mass sensitivity by 20 times. Sample<br />
components can be collected in small elution volumes (1-50 μL) for<br />
further sequence or mass analysis. Microbore offers major benefits in<br />
pharmacokinetic assays and LC/MS applications. The typical flow<br />
rate range is 10-100 μL/min., therefore specialized HPLC systems<br />
may be required for optimum column performance.<br />
■ Increase sensitivity and decrease solvent consumption by a factor of 20<br />
(compared with 4.6 mm i.d.)<br />
■ Reduce sample size for pharmacokinetic assays<br />
■ Better compatibility with LC/MS interfaces<br />
■ Each column is individually tested<br />
250 mm, 100 mm Microbore Columns (1.0 mm i.d.)<br />
Modes of Separation<br />
Reversed-Phase Chromatography (RPC) is the most popular HPLC mode<br />
and is used in 60-80% of all applications. In RPC, hydrophobic groups<br />
(C18, C8, or C4) bonded to a silica support are used together with a<br />
mobile phase of water and organic solvent (e.g. methanol, acetonitrile).<br />
Polar Phase (Normal Phase) Chromatography (NPC) uses a polar stationary<br />
phase (unbonded silica, bonded amino or cyano group) together<br />
with a non-polar mobile phase (e.g., hexane). NPC is useful for<br />
functional group analysis, isomeric separations, purification of<br />
organics, and sample cleanup.<br />
Ion-Exchange Chromatography (IEC) utilizes bonded ionic groups to<br />
separate ionic analytes. Retention is based on the affinity of various<br />
analyte ions for the stationary phase and various mobile phase<br />
parameters (e.g., pH, ionic strength).<br />
Brownlee Analytical<br />
This is PerkinElmer’s all-purpose HPLC column line for<br />
conventional as well as high speed LC separations. The (110 Å)<br />
silica is equivalent to the Hypersil. Columns are available in 3<br />
or 5 μ and lengths ranging from 30-250 mm, in 2.1 and 4.6 i.d.<br />
The Brownlee Analytical family includes Amino, C18, C8,<br />
Cyano, Phenyl, Silica, and PAH phases.<br />
Brownlee Aquapore ®<br />
This is a wide-pore (300 Å, 7, and 20 μm), silica-based support<br />
suitable for the separation of large biopolymers<br />
Brownlee Bio<br />
This material is wide-pore silica (300 Å) that is excellent for peptide<br />
and protein separation. Columns are available in 5 μ and lengths<br />
ranging from 30-250 mm, in 2.1 and 4.6 i.d. in C8 and C18 phases.<br />
Brownlee CHOICE TM<br />
This line of columns is made of (60 Å) silica which results in large<br />
surface area, high carbon loads, and high retention compounds.<br />
Columns are available in 3 or 5 μm and lengths ranging from<br />
30-250 mm, in 2.1 and 4.6 i.d. The Brownlee Choice family<br />
includes the Basix, C18, Organic Acids, and PFP Propyl phases.<br />
Brownlee Spheri-5 ®<br />
This is a small-pore (80 Å, 5 μm), silica based sorbent for separating<br />
small molecules. Both monofunctional (comb-pre) and polyfunctional<br />
(polymerized loop-type) C8 and C18 sorbents available<br />
Brownlee Validated TM<br />
These columns are made on high-purity, Type B silica with<br />
inherent low silanophilic activity. It exhibits excellent peak shape<br />
for a wide range of compounds while also having a wide number<br />
of phases. The Brownlee Validated columns are the best choice<br />
for pharmaceutical applications that deal with a lot of basic or<br />
multi-functional compounds. Columns are available in 3 or 5 μ<br />
and lengths ranging from 30-250 mm, in 2.1 and 4.6 i.d., and<br />
include Amino, C18, C8, Carbamate, Cyano, IBD (intrinsically<br />
base-deactivated), PFP (pentafluorophenyl) and phenyl phases.<br />
Guard Columns and Cartridges<br />
To protect your column investment, we offer a complete line of<br />
guard columns in our direct connect guard cartridges. These can be<br />
attached to any column offered above. You can easily select the<br />
phase type to the appropriate guard column packing to ensure a<br />
correct silica match.<br />
294
Conventional Columns<br />
Conventional Columns Selection and Specification Guide<br />
Specifications<br />
Support Types<br />
Silica is the most common HPLC support. It is efficient and rugged, but has a limited pH range of 2-7. Polymer-based<br />
supports (polystyrene copolymer) offer a greater pH range of 1-14, but have lower pressure ratings and some limitations<br />
with organic solvents. Small-pore (80-100 Å) supports are used for small molecules, while wide-pore supports (300 Å)<br />
are better suited for proteins or other macro-molecules.<br />
Brownlee Pore % End<br />
Product Functionality Diameter (Å) Carbon Cap Applications Page No.<br />
Analytical Amino 110 2 No General purpose, excellent for carbohydrate analysis 308<br />
Analytical C18 110 13 Yes Superior general purpose for non-basic analytes 308<br />
Analytical C8 110 7 Yes Superior general purpose for non-basic analytes 308<br />
Analytical Cyano 110 4 Yes General purpose analysis Cyano used in either normal or reversed phase analytes 308<br />
Analytical Phenyl 110 6 Yes General purpose Phenyl for neutral analytes 308<br />
Analytical Silica 110 - - Ideal for polar analytes 308<br />
Analytical PAH 110 - Yes Maximum resolution of polynuclear aromatic hydrocarbons 308<br />
Bio C18 300 6 Yes Excellent for high molecular weight compounds and proteins 309<br />
Bio C8 300 - - Excellent for high molecular weight compounds and proteins 309<br />
CHOICE TM Basix 60 12 Yes Excellent for amine-containing compounds and basic pharmaceuticals. 310<br />
Ideal for LC/MS<br />
CHOICE C18 60 27 Yes Separates basic compounds showing good deactivation. 310<br />
Excellent for explosives or steroids<br />
CHOICE Organic Acids 60 - No Use for challenging organic acids 310<br />
CHOICE PFP Propyl 60 17 Yes Ideal for MS, ELSD, or NPD detection of nucleosides, nucleotides, 310<br />
purines, pyrimidines or halogenated compounds<br />
Validated TM Amino 100 2 No Ideal for carbohydrates 311<br />
Validated C1 100 5 - Exceptional stable C1 phase. Least retentive reversed phase hydrocarbon packing 311<br />
Validated C4 100 9 Yes High bonding coverage and base deactivation. Less retention than C18 or C8 311<br />
Validated Aqueous C18 100 15 No Excellent for highly water soluble or poorly organic soluble compounds 311<br />
such as water soluble vitamins and organic acids<br />
Validated C18 100 20 Yes Used for the detection of anilines, barbiturates, carbonyls, fat-soluble vitamins, 311<br />
fatty acids, glycerides, phthalates, PTH amino acids, steroids, other acids<br />
Validated C8 100 12 Yes Less hydrophobic retention than Brownlee Validated C18 311<br />
Validated Carbamate 100 - - Fast analysis of carbamates 312<br />
Validated Cyano 100 8 Yes Excellent for basic pharmaceuticals and steroids 312<br />
Validated IBD 100 12 No Unique separation for acids, bases, zwitterions, and other polar compounds 312<br />
Validated PFP 100 7 Yes Ideal for taxors and precursors or halogenated compounds, 312<br />
amines, esters or ketones<br />
Validated Phenyl 100 10 Yes Ideal for the separation of fatty acids, polynuclear aromatic hydrocarbons, 312<br />
purines and pyrimidines<br />
Conventional Columns Liquid Chromatography<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
295
Conventional Columns<br />
Conventional Column Applications<br />
Subject<br />
Biochemical<br />
Page No.<br />
Liquid Chromatography Conventional Columns<br />
Adenine, Adenosine, ATP, ADP, and AMP 297<br />
Aromatic Amino Acids 297<br />
Carboxylic Acids 297<br />
Nucleic Acid Bases 297<br />
Nucleotides, Nucleosides, and Nitrogenous Bases 298<br />
Purines/Pyrimidines 298<br />
Thymine, Thymidine, TTP, TDP, and TMP 298<br />
Dietary Supplements/Plant Extracts<br />
Allicin in Garlic Tablets 299<br />
Hyperforin in St. John’s Wort 299<br />
Phenethyl Glucosinsolate 299<br />
Vitamins (Fat Soluble) 299<br />
Environmental<br />
Aldehydes and Ketones (DNPH derivatives) 300<br />
Explosives by EPA Method 8330 C18 300<br />
Explosives by EPA Method 8330 Cyano 300<br />
Herbicides (Phenoxyacid Mix A) 301<br />
Herbicides (Phenoxyacid Mix B) 301<br />
Herbicides (Phenylureas) 302<br />
Pesticides 302<br />
Pesticides (Carbamates) 303<br />
Polynuclear Aromatic Hydrocarbons 303<br />
Food and Flavors<br />
Heat Level Assay for Habenero Nuggets 304<br />
Organic Acids in Grape Juice 304<br />
Organic Acids Standards 304<br />
Sugars 304<br />
Pharmaceutical<br />
Analgesic Acetaminophen and Narcotic Analgesics 305<br />
Analgesic Acetaminophen and Narcotic Analgesics 305<br />
Antiarrhythmic Atenolol 305<br />
Antiarrhythmic Calcium Channel Blockers 305<br />
Antibiotic Amoxicillin 306<br />
Antibiotic Sulfamethoxazole, Trimethoprim, and Napththoate 306<br />
Antidepressants (Tricyclic) 306<br />
Corticosteroids 306<br />
Corticosteroids – Standards 307<br />
Hormones B-Estridol, Norethindrone, and Ethynyl Estadiol 307<br />
Narcotic Analgesic Hydrocodone Bitartrate by USP 25 307<br />
296
Adenine, Adenosine, ATP, ADP, and AMP<br />
1<br />
2<br />
3<br />
0 2 4 6 8 10 12 14 16 18 20<br />
TIME (MIN.)<br />
CHROMATOGRAPHIC CONDITIONS<br />
Column: Brownlee Validated IBD<br />
Dimensions: 150 x 4.6 mm, 5 μm, 100 Å<br />
Detection: UV @ 260 nm<br />
Solvent: 20 mM Ammonium Acetate, pH 5.8<br />
Mobile Phase: 20 mM Ammonium Acetate, pH 5.8: Methanol (97.5:2.5)<br />
Flow Rate: 1.0 mL/min. @ 35 °C<br />
Injection: 20 μL<br />
Part No.<br />
4<br />
N9303582<br />
Aromatic Amino Acids<br />
Peak Identification<br />
1.<br />
2.<br />
3.<br />
5<br />
Conc.<br />
Peak Identification (μg/mL)<br />
1. ATP 258<br />
2. ADP 320<br />
3. AMP 274<br />
4. Adenine 84<br />
5. Adenosine 254<br />
CHROMATOGRAPHIC CONDITIONS<br />
Column: Brownlee Validated Aqueous C18<br />
Dimensions: 150 x 4.6 mm, 5 μm, 100 Å<br />
Detection: UV @ 254 nm<br />
Solvent: Mobile Phase A<br />
Mobile Phases: A: 50 mM Potassium Phosphate, pH 2.5<br />
B: Acetonitrile 5-20% B: 0-5 min. 20-5% B: 5-6 min.<br />
Hold at 5% B: 6-13 min.<br />
Flow Rate: 1.0 mL/min.<br />
Temperature: 30 °C<br />
Injection: 20 μL<br />
Part No.<br />
Tyrosine 0.2<br />
Phenylalanine 1.6<br />
Tryptophan 0.4<br />
N9303546<br />
Conc.<br />
(mg/mL)<br />
1<br />
0 2 4 6 8 10<br />
TIME (MIN.)<br />
2<br />
Conventional Column Applications<br />
3<br />
Carboxylic Acids<br />
Peak Identification<br />
1.<br />
2.<br />
3.<br />
4.<br />
5.<br />
6.<br />
Conc.<br />
(mg/mL)<br />
Malonic Acid 500<br />
Lactic Acid 500<br />
Acetic Acid 1000<br />
Citric Acid 1000<br />
Succinic Acid 2000<br />
Fumaric Acid 10<br />
Biochemical<br />
CHROMATOGRAPHIC CONDITIONS<br />
Column: Brownlee Validated Aqueous C18<br />
Dimensions: 150 x 4.6 mm, 5 μm, 100 Å<br />
Detection: UV @ 210 nm<br />
Solvent: Water<br />
Mobile Phase: 50 mM Potassium Phosphate, pH 2.5: Acetonitrile (99:1)<br />
Flow Rate: 1.5 mL/min.<br />
Temperature: 25 °C<br />
Injection: 10 μL<br />
Part No.<br />
N9303546<br />
Nucleic Acid Bases<br />
1<br />
0 1 2 3 4<br />
TIME (MIN.)<br />
CHROMATOGRAPHIC CONDITIONS<br />
Column: Brownlee Choice PFP Propyl<br />
Dimensions: 150 x 4.6 mm, 5 μm, 60 Å<br />
Conc.: 100 μg/mL each<br />
Detection: UV @ 260 nm<br />
Solvent: 20 mM Ammonium Acetate, pH 5.0 (Note: 1–3 drops of<br />
Ammonium Hydroxide added to keep Guanine in solution)<br />
Mobile Phase: 20 mM Ammonium Acetate, pH 5.0:Methanol (85:15, v/v)<br />
Flow Rate: 1.0 mL/min.<br />
Temperature: Ambient<br />
Injection: 1.0 μL<br />
Part No.<br />
1<br />
2 3<br />
N9303644<br />
4<br />
2<br />
3<br />
4<br />
5<br />
6<br />
Peak Identification<br />
1.<br />
2.<br />
3.<br />
4.<br />
5.<br />
Cytosine<br />
Uracil<br />
Guanine<br />
Thymine<br />
Adenine<br />
0 1 2 3 4 5 6 7 8 9<br />
TIME (MIN.)<br />
5<br />
Conventional Column Applications Liquid Chromatography<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
297
Conventional Column Applications<br />
Biochemical<br />
Liquid Chromatography Conventional Column Applications<br />
Nucleotides, Nucleosides, and Nitrogenous Bases<br />
Peak Identification<br />
1.<br />
2.<br />
3.<br />
4.<br />
5.<br />
6.<br />
7.<br />
8.<br />
9.<br />
10.<br />
11.<br />
Conc.<br />
(μg/mL)<br />
CDP 146<br />
CMP 113<br />
ATP 117<br />
ADP 145<br />
Cytidine 155<br />
TMP 157<br />
AMP 125<br />
Guanine 36<br />
Guanosine 103<br />
Adenine 38<br />
Adenosine 115<br />
CHROMATOGRAPHIC CONDITIONS<br />
Column: Brownlee Validated IBD<br />
Dimensions: 150 x 4.6 mm, 5 μm<br />
Detection: UV @ 260 nm<br />
Solvent: 20 mM Ammonium Acetate, pH 5.8<br />
Mobile Phase: 20 mM Ammonium Acetate, pH 5.8: Methanol (97.5:2.5)<br />
Flow Rate: 1.0 mL/min.<br />
Temperature: 35 °C<br />
Injection: 20 μL<br />
Part No.<br />
N9303582<br />
Purines/Pyrimidines<br />
1<br />
2<br />
3<br />
4<br />
5<br />
6<br />
7<br />
8<br />
4 6 7<br />
2<br />
1 3<br />
5<br />
8<br />
9<br />
10<br />
11<br />
0 2 4 6 8 10 12 14 16 18<br />
TIME (MIN.)<br />
9 10<br />
0 5 10 15 20 25<br />
TIME (MIN.)<br />
11<br />
13 14<br />
12<br />
Thymine, Thymidine,<br />
TTP, TDP, and TMP<br />
Conc.<br />
Peak Identification (μg/mL)<br />
1. TTP 224<br />
2. TDP 152<br />
3. TMP 346<br />
4. Thymine 88<br />
5. Thymidine 318<br />
CHROMATOGRAPHIC CONDITIONS<br />
Column: Brownlee Validated IBD<br />
Dimensions: 150 x 4.6 mm, 5 μm, 100 Å<br />
Detection: UV @ 260 nm<br />
Solvent: 200 mM Ammonium Acetate, pH 5.8<br />
Mobile Phase: 20 mM Ammonium Acetate, pH 5.8: Methanol (97.5:2.5)<br />
Flow: 1.0 mL/min.<br />
Temperature: 35 °C<br />
Injection: 20 μL<br />
Part No.<br />
Peak Identification<br />
1.<br />
2.<br />
3.<br />
4.<br />
5.<br />
6.<br />
7.<br />
8.<br />
9.<br />
10.<br />
11.<br />
12.<br />
13.<br />
14.<br />
Cytosine<br />
5-Methylcytosine<br />
Uracil<br />
Uric Acid<br />
Hypoxanthine<br />
Xanthine<br />
Thymine<br />
Purine<br />
Theobromine<br />
Ethyluracil<br />
6-Methylpurine<br />
1, 7-Dimethylxanthine<br />
Theophylline<br />
Propyluracil<br />
CHROMATOGRAPHIC CONDITIONS<br />
Column: Brownlee Validated PFP<br />
Dimensions: 250 x 4.6 mm, 5 μm, 100 Å<br />
Conc.: 100 mg/mL each<br />
Detection: UV @ 260 nm<br />
Solvent: Mobile Phase<br />
Mobile Phase: 0.001% Formic Acid in Water: Methanol (50:50, v/v)<br />
Flow Rate: 1.0 mL/min.<br />
Temperature: Ambient<br />
Injection: 10 μL<br />
Part No.<br />
N9303582<br />
N9303600<br />
1<br />
2<br />
3<br />
4<br />
5<br />
0 2 4 6 8 10 12 14 16<br />
TIME (MIN.)<br />
298
Allicin in Garlic Tablets<br />
CHROMATOGRAPHIC CONDITIONS<br />
Column: Brownlee Analytical C18<br />
Dimensions: 150 x 4.6 mm, 5 μm, 110 Å<br />
Conc.: 1.2 mg/mL Garlic Tablet in Water<br />
Detection: UV @ 240 nm<br />
Solvent: Deionized Water<br />
Mobile Phase: Water:Methanol (50:50, v/v)<br />
Flow Rate: 0.8 mL/min.<br />
Temperature: 30 °C<br />
Injection: 20 μL<br />
Part No.<br />
N9303513<br />
Peak Identification<br />
1.<br />
Allicin<br />
0 2 4 6 8<br />
TIME (MIN.)<br />
Hyperforin in St. John’s Wort<br />
1<br />
CHROMATOGRAPHIC CONDITIONS<br />
Column: Brownlee Analytical C18<br />
Dimensions: 150 x 4.6 mm, 5 μm, 110 Å<br />
Sample: St. John’s Wort capsule<br />
Conc.: 4.17 mg/mL<br />
Detection: UV @ 270 nm<br />
Solvent: Methanol<br />
Mobile Phase: 0.01 N Phosphate Buffer, pH 2.5: Acetonitrile (15:85, v/v)<br />
Flow Rate: 1.2 mL/min.<br />
Autosampler: 15 °C<br />
Temperature: 30 °C<br />
Injection: 20 μL<br />
Part No.<br />
N9303513<br />
Peak Identification<br />
1.<br />
2.<br />
Hyperforin<br />
Adhyperforin<br />
0 2 4 6 8 10 12 14 16<br />
TIME (MIN.)<br />
1<br />
2<br />
Conventional Column Applications<br />
Dietary Supplements/Plant Extracts<br />
Phenethyl Glucosinolate<br />
Peak Identification<br />
1.<br />
Part No.<br />
Vitamins (Fat Soluble)<br />
CHROMATOGRAPHIC CONDITIONS<br />
Column: Brownlee Validated C18<br />
Dimensions: 250 x 4.6 mm, 5 μm, 100 Å<br />
Detection: UV @ 280 nm<br />
Solvent: Diethyl Ether<br />
Mobile Phase: Acetonitrile:Methanol (90:10, v/v)<br />
Time (min.) Flow (mL/min.)<br />
1.00 1.00<br />
5.00 1.00<br />
5.01 2.00<br />
50.0 2.00<br />
Temperature: 30 °C<br />
Part No.<br />
Phenethyl Glucosinolate<br />
CHROMATOGRAPHIC CONDITIONS<br />
Column: Brownlee Validated Aqueous C18<br />
Dimensions: 150 x 4.6 mm, 5 μm, 100 Å<br />
Conc.: 1000 μg/mL<br />
Detection: UV @ 210 nm<br />
Solvent: Water<br />
Mobile Phase: A: 50 mM Potassium Phosphate, pH 2.5 B: Acetonitrile<br />
Time (min.) %B<br />
0.0 0<br />
10 75<br />
11 0<br />
16 0<br />
Flow Rate: 1.0 mL/min.<br />
Temperature: Ambient<br />
Injection: 10 μL<br />
1<br />
2<br />
3<br />
N9303546<br />
0 10 20 30 40<br />
TIME (MIN.)<br />
4<br />
5<br />
6 7<br />
8<br />
N9303561<br />
9<br />
Peak Identification<br />
1.<br />
2.<br />
3.<br />
4.<br />
5.<br />
6.<br />
7.<br />
8.<br />
9.<br />
1<br />
0 2 4 6 8 10 12 14<br />
TIME (MIN.)<br />
Conc.<br />
mg/mL<br />
Solvent Front n/a<br />
Menadione 0.45<br />
(Vitamin K3)<br />
All-trans-retinol 0.34<br />
(Vitamin A)<br />
Vitamin D3 0.4<br />
Unknown<br />
n/a<br />
Tocopherol 2.4<br />
(Vitamin E)<br />
Tocopherol Acetate 2.4<br />
(Vitamin E Acetate)<br />
Unknown<br />
n/a<br />
Phylloquinone 0.84<br />
(Vitamin K1)<br />
Conventional Column Applications Liquid Chromatography<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
299
Conventional Column Applications<br />
Environmental<br />
Liquid Chromatography Conventional Column Applications<br />
Aldehydes and Ketones (DNPH derivatives)<br />
1<br />
2<br />
3<br />
4<br />
5<br />
6 8<br />
7 9<br />
10 11<br />
12 13<br />
0 2 4 6 8 10 12 14<br />
TIME (MIN.)<br />
Explosives by EPA Method 8330<br />
Peak Identification<br />
1.<br />
2.<br />
3.<br />
4.<br />
5.<br />
6.<br />
7.<br />
8.<br />
9.<br />
10.<br />
11.<br />
12.<br />
13.<br />
14.<br />
CHROMATOGRAPHIC CONDITIONS<br />
Column: Brownlee Analytical C18<br />
Dimensions: 250 x 4.6 mm, 5 μm, 110 Å<br />
Conc.: 500 μg/mL each component<br />
Detection: UV @ 254 nm<br />
Solvent: Acetonitrile<br />
Mobile Phase: Water:Methanol (50:50, v/v)<br />
Flow Rate: 1.5 mL/min.<br />
Temperature: 27 °C<br />
Injection: 3 μL<br />
Part No.<br />
HMX<br />
RDX<br />
1, 3, 5-Trinitrobenzene<br />
1, 3-Dinitrobenzene<br />
Tetryl<br />
Nitrobenzene<br />
2, 4, 6-Trinitrotoluene<br />
2-Amino-4, 6-Dinitrotoluene<br />
4-Amino-2, 6-Dinitrotoluene<br />
2, 6-Dinitrotoluene<br />
2, 4-Dinitrotoluene<br />
2-Nitrotoluene<br />
4-Nitrotoluene<br />
3-Nitrotoluene<br />
N9303514<br />
1<br />
2<br />
3<br />
4<br />
6<br />
5<br />
0 2 4 6 8 10 12<br />
TIME (MIN.)<br />
DNPH Derivatives of:<br />
1. Formaldehyde<br />
2. Acetaldehyde<br />
3. Acetone<br />
4. Acrolein<br />
5. Propionaldehyde<br />
6. Crotonaldehyde<br />
7. MEK<br />
8. Methacrolein<br />
9. Butyraldehyde<br />
10. Benzaldehyde<br />
11. Valeraldehyde<br />
12. m-Tolualdehyde<br />
13. Hexanaldehyde<br />
CHROMATOGRAPHIC CONDITIONS<br />
Column: Brownlee Validated C18<br />
Dimensions: 150 x 4.6 mm, 5 μm, 100 Å<br />
Conc.: 30 μg/mL each, as derivative<br />
Mobile Phase: Solvent A: Water, Solvent B: Acetonitrile,<br />
Solvent C: Tetrahydrofuran, 50-30% A/30-65%<br />
B/20-5% C, 0-15 min.<br />
Flow Rate: 1.5 mL/min.<br />
Wavelength: 365 nm<br />
Temperature: 40 °C<br />
Injection: 10 μL<br />
Part No.<br />
N9303558<br />
Explosives by EPA Method 8330<br />
Peak Identification<br />
5<br />
1.<br />
2.<br />
3.<br />
Nitrobenzene<br />
2-Nitrotoluene<br />
4-Nitrotoluene<br />
6<br />
4. 3-Nitrotoluene<br />
1<br />
4<br />
11<br />
5. 1, 3-Dinitrobenzene<br />
8<br />
3<br />
6. 1, 3, 5-Trinitrobenzene<br />
2<br />
7<br />
7. 2, 6-Dinitrotoluene<br />
9<br />
8. 2, 4-Dinitrotoluene<br />
9<br />
12<br />
12. RDX<br />
13 14 13. Tetryl<br />
13<br />
9. 2, 4, 6-Trinitrotoluene<br />
7 11<br />
8<br />
10. 4-Amino-2, 6-Dinitrotoluene<br />
10<br />
11. 2-Amino-4, 6-Dinitrotoluene<br />
10<br />
14. HMX<br />
12<br />
0 2 4 6 8 10 12 14<br />
TIME (MIN.)<br />
CHROMATOGRAPHIC CONDITIONS<br />
Column: Brownlee Analytical Cyano<br />
Dimensions: 250 x 4.6 mm, 5 μm, 110 Å<br />
Conc.: 500 μg/mL each component<br />
Detection: UV @ 254 nm<br />
Solvent: Acetonitrile<br />
Mobile Phase: Water: Methanol (50:50, v/v)<br />
Flow Rate: 1.5 mL/min.<br />
Temperature: 27 °C<br />
Injection: 3 μL<br />
Part No.<br />
N9303523<br />
14<br />
300
Herbicides (Phenoxyacid Mix A)<br />
1<br />
5 6 7 8 9 10 11 12 13 14 15 16 17<br />
TIME (MIN.)<br />
Herbicides (Phenoxyacid Mix B)<br />
1<br />
2<br />
2<br />
3 4<br />
5<br />
Conventional Column Applications<br />
6 7<br />
12 14 16 18 20 22 24 26<br />
TIME (MIN.)<br />
3<br />
4 5<br />
6<br />
7<br />
8<br />
8<br />
9<br />
9<br />
1. Picloram<br />
2. Chloramben<br />
3. Dicamba<br />
4. Bentazon<br />
5. 2, 4-D<br />
6. Dichlorprop<br />
7. 2, 4, 5-TP<br />
8. Acifluorfen<br />
9. 1, 4-Dichlorobenzene (IS)<br />
Environmental<br />
CHROMATOGRAPHIC CONDITIONS<br />
Column: Brownlee Aqueous<br />
Dimensions: 150 x 4.6 mm, 5 μm, 100 Å<br />
Sample Diluent: Acetonitrile<br />
Conc.: 10 ppm each herbicide<br />
Detection: UV @ 225 nm<br />
Mobile Phase: A: 0.05% H 3 PO 4 B: Acetonitrile<br />
Time (min.) %B<br />
0 10<br />
10 45<br />
16 45<br />
22 90<br />
24 90<br />
25 10<br />
Flow Rate: 1.0 mL/min.<br />
Temperature: Ambient<br />
Injection: 10 μL<br />
Part No.<br />
N9303546<br />
1. 4-Nitrophenol<br />
2. MCPA<br />
3. 3, 5-Dichlorobenzoic acid<br />
4. MCPP<br />
5. 2, 4, 5-T<br />
6. 2, 4-DB<br />
7. 1, 4-Dichlorobenzene (IS)<br />
8. Dinoseb<br />
9. Pentachlorophenol<br />
CHROMATOGRAPHIC CONDITIONS<br />
Column: Brownlee Validated<br />
Dimensions: 150 x 4.6 mm, 5 μm, 100 Å<br />
Sample Diluent: Acetonitrile<br />
Conc.: 10 ppm each herbicide<br />
Detection: UV @ 225 nm<br />
Mobile Phase: A: 0.05% H 3 PO 4 B: Acetonitrile<br />
Time (min.) %B<br />
0 10<br />
10 45<br />
16 45<br />
22 90<br />
24 90<br />
25 10<br />
Flow Rate: 1.0 mL/min.<br />
Temperature: Ambient<br />
Injection: 10 μL<br />
Part No.<br />
N9303546<br />
Conventional Column Applications Liquid Chromatography<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
301
Conventional Column Applications<br />
Environmental<br />
Liquid Chromatography Conventional Column Applications<br />
Herbicides (Phenylurea)<br />
1<br />
2<br />
3<br />
0 10 20<br />
TIME (MIN.)<br />
Pesticides<br />
1<br />
2<br />
4<br />
5 6<br />
3<br />
4, 5<br />
6<br />
7<br />
8<br />
0 10 20 30<br />
TIME (MIN.)<br />
9<br />
7<br />
10 11<br />
8<br />
12<br />
1.<br />
2.<br />
3.<br />
4.<br />
5.<br />
6.<br />
7.<br />
8.<br />
9.<br />
10.<br />
11.<br />
12.<br />
13.<br />
14.<br />
15.<br />
16.<br />
17.<br />
9<br />
10<br />
Desisopropyl Atrazine<br />
Desethyl Atrazine<br />
Simazine<br />
Terbuthylazine Desethyl<br />
Cyanazine<br />
Methabenzthiazuron<br />
Chlortoluron<br />
Atrazine<br />
Secbumeton<br />
Isoproturon<br />
Diuron<br />
Terbumeton<br />
Terbuthylazine<br />
Linuron<br />
Flusilazole<br />
Ethofumerate<br />
Neburon<br />
13<br />
14<br />
15<br />
16<br />
17<br />
Peak Identification<br />
1.<br />
2.<br />
3.<br />
4.<br />
5.<br />
6.<br />
7.<br />
8.<br />
9.<br />
10.<br />
Tebuthiuron 2<br />
Thidiazuron 2<br />
Monuron 5<br />
Fluometuron 2<br />
Diuron 2<br />
Propanil 2<br />
Siduron 2<br />
Linuron 2<br />
Carbazole 5<br />
Diflubenzuron 2<br />
CHROMATOGRAPHIC CONDITIONS<br />
Column: Brownlee Validated C18<br />
Dimensions: 150 x 4.6 mm, 5 μm, 100 Å)<br />
Sample Diluent: Acetonitrile<br />
Detection: UV @ 245 nm<br />
Mobile Phase: A: 25 mM Phosphate Buffer, pH 2.5 B: Acetonitrile<br />
Time (min.) %B<br />
0 40<br />
8 40<br />
14 55<br />
18 55<br />
19 40<br />
Flow Rate: 1.5 mL/min.<br />
Temperature: Ambient<br />
Injection: 20 μL<br />
Part No.<br />
N9303558<br />
Conc.<br />
(μg/mL or ppm)<br />
CHROMATOGRAPHIC CONDITIONS<br />
Column: Brownlee Choice C18<br />
Dimensions: 150 x 4.6 mm, 5 μm, 60 Å<br />
Conc.: Approx. 10 ppm each pesticide<br />
Detection: UV @ 220 nm<br />
Solvent: Acetonitrile<br />
Mobile Phase: A: 20 mM K 2 HPO 4 , pH 7.0 B: Acetonitrile<br />
Time (min.) %B<br />
0 20<br />
10 40<br />
15 40<br />
30 70<br />
30.1 20<br />
Flow Rate: 1.2 mL/min.<br />
Temperature: Ambient<br />
Injection: 5 μL<br />
Part No.<br />
N9303628<br />
302
Pesticides (Carbamates)<br />
1 2 3 4<br />
5<br />
0 2 4 6 8 10<br />
TIME (MIN.)<br />
6<br />
7 8<br />
10<br />
Polynuclear Aromatic Hydrocarbons<br />
Peak Identification<br />
1.<br />
2.<br />
3.<br />
4.<br />
5.<br />
6.<br />
7.<br />
8.<br />
9.<br />
10.<br />
11.<br />
12.<br />
13.<br />
14.<br />
15.<br />
16.<br />
9<br />
Conc.<br />
(μg/mL)<br />
Naphthalene 100<br />
Acenaphthylene 100<br />
Acenaphthene 100<br />
Fluorene 100<br />
Phenanthrene 50<br />
Anthracene 100<br />
Fluoranthene 50<br />
Pyrene 50<br />
Benzo(a)anthracene 50<br />
Chrysene 50<br />
Benzo(b)fluoranthene 50<br />
Benzo(k)fluoranthene 50<br />
Benzo(a)pyrene 50<br />
Dibenzo(a,h)anthracene 50<br />
Benzo(ghi)perylene 50<br />
Indeno(1, 2, 3-cd)pyrene 50<br />
1<br />
2<br />
11<br />
3<br />
4<br />
Conventional Column Applications<br />
1.<br />
2.<br />
3.<br />
4.<br />
5.<br />
6.<br />
7.<br />
8.<br />
9.<br />
10.<br />
11.<br />
Aldicarb<br />
Aldicarb Sulfoxide<br />
Oxamyl<br />
Methomyl<br />
3-Hydroxycarbofuran<br />
Aldicarb<br />
Propoxur<br />
Carbofuran<br />
Carbaryl<br />
Methiocarb<br />
4-Bromo-3, 5-Dimethylcarbamate<br />
Part No.<br />
0 2 4 6 8 10 12 14 16 18<br />
TIME (MIN.)<br />
5<br />
6<br />
7 8<br />
9<br />
10<br />
11<br />
12<br />
13<br />
N9303570<br />
Environmental<br />
CHROMATOGRAPHIC CONDITIONS<br />
Column: Brownlee Validated Carbamate<br />
Dimensions: 50 x 4.6 mm, 3 μm, 100 Å<br />
Conc.: 50 μg/mL each<br />
Detection: UV @ 220 nm<br />
Solvent: Methanol<br />
Mobile Phase: A: 90:10 Water: Methanol B: 90:10 Methanol: Acetonitrile<br />
Time (min.) %B<br />
0 10<br />
10 90<br />
Flow Rate: 1.5 mL/min.<br />
Temperature: 27 °C<br />
Injection: 5 μL<br />
14 15 16<br />
CHROMATOGRAPHIC CONDITIONS<br />
Column: Brownlee Analytical PAH<br />
Dimensions: 150 x 3.2 mm, 5 μm, 110 Å<br />
Detection: UV @ 254 nm<br />
Solvent: 1:9 Methylene Chloride:Acetonitrile<br />
Mobile Phase: A: Purified Water B: Acetonitrile<br />
Time (min.) %B<br />
0 40<br />
7 60<br />
11 100<br />
18 40<br />
Flow Rate: 1.2 mL/min.<br />
Temperature: Ambient<br />
Injection: 5 μ<br />
Part No.<br />
N9303430<br />
Conventional Column Applications Liquid Chromatography<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
303
Conventional Column Applications<br />
Food and Flavors<br />
Liquid Chromatography Conventional Column Applications<br />
Heat Level Assay for Habeñero Nuggets<br />
Peak Identification<br />
1.<br />
2.<br />
3.<br />
Part No.<br />
Organic Acids in Grape Juice<br />
CHROMATOGRAPHIC CONDITIONS<br />
Column: Brownlee Choice Organic Acids<br />
Dimensions: 300 x 4.6 mm, 5 μm, 60 Å<br />
Conc.: Grape Juice: Water (50:50, v/v)<br />
Detection: UV @ 226 nm<br />
Solvent: Purified Water<br />
Mobile Phase: 100 mM Phosphate Buffer, pH 2.5<br />
Flow Rate: 0.5 mL/min.<br />
Temperature: Ambient<br />
Injection: 10 μL<br />
Part No.<br />
Unknown<br />
Capsaicin<br />
Dihydrocapsaicin<br />
0 1 2 3 4 5 6 7 8<br />
TIME (MIN.)<br />
CHROMATOGRAPHIC CONDITIONS<br />
Column: Brownlee Analytical C18<br />
Dimensions: 150 x 4.6 mm, 5 μm, 110 Å<br />
Conc.: 4000 μg/mL<br />
Detection: UV @ 280 nm<br />
Solvent: Ethanol<br />
Mobile Phase: A: 1% Acetic Acid in Water (v/v) B: Acetonitrile<br />
Time (min.) %B<br />
0 50<br />
2 50<br />
9 80<br />
12 80<br />
13 50<br />
Flow Rate: 1.0 mL/min.<br />
Temperature: Ambient<br />
Injection: 10 μL Habeñero Nugget Extract<br />
1<br />
N9303513<br />
2<br />
N9303634<br />
Peak Identification<br />
1.<br />
2.<br />
0 5 10 15 20 25 30 35 40<br />
TIME (MIN.)<br />
1<br />
2<br />
Tartaric Acid<br />
Malic Acid<br />
3<br />
Organic Acids Standard<br />
0 5 10 15 20 25 30 35 40<br />
TIME (MIN.)<br />
CHROMATOGRAPHIC CONDITIONS<br />
Column: Brownlee Choice Organic Acids<br />
Dimensions: 300 x 4.6 mm, 5 μm, 60 Å<br />
Detection: UV @ 226 nm<br />
Solvent: Purified Water<br />
Mobile Phase: 100 mM Phosphate Buffer, pH 2.5<br />
Flow Rate: 0.5 mL/min.<br />
Temperature: Ambient<br />
Injection: 10 μL<br />
Part No.<br />
Sugars<br />
N9303634<br />
CHROMATOGRAPHIC CONDITIONS<br />
Column: Brownlee Validated Amino<br />
Dimensions: 150 x 4.6 mm, 3 μm, 100 Å<br />
Detection: Refractive Index @ 35 °C<br />
Solvent: Mobile Phase<br />
Mobile Phase: Water:Acetonitrile (25:75, v/v)<br />
Flow Rate: 0.8 mL/min.<br />
Temperature: 35 °C<br />
Injection: 20 μL<br />
Part No.<br />
1<br />
2<br />
3<br />
Peak Identification<br />
1.<br />
2.<br />
3.<br />
4.<br />
5.<br />
Fructose 2.0<br />
Glucose 2.1<br />
Sucrose 4.0<br />
Maltose 4.5<br />
Lactose 4.4<br />
N9303534<br />
Conc.<br />
(mg/mL)<br />
4<br />
Peak Identification<br />
1.<br />
2.<br />
3.<br />
4.<br />
5.<br />
Tartaric Acid 1<br />
Quinic Acid 1<br />
Malic Acid 1<br />
Citric Acid<br />
Fumaric Acid<br />
5<br />
1<br />
2<br />
Conc.<br />
(μg/mL)<br />
0 2 4 6 8 10 12 14<br />
TIME (MIN.)<br />
3<br />
4<br />
5<br />
304
Analgesic Acetaminophen<br />
and Narcotic Analgesics<br />
Peak Identification<br />
1.<br />
2.<br />
3.<br />
4.<br />
Acetaminophen<br />
Codeine<br />
Oxycodone<br />
Hydroxycodone<br />
0 1 2 3 4 5 6 7 8 9<br />
TIME (MIN.)<br />
CHROMATOGRAPHIC CONDITIONS<br />
Column: Brownlee Choice<br />
Dimensions: 150 x 4.6 mm, 5 μm, 60 Å<br />
Conc.: 100 μg/mL<br />
Detection: UV @ 280 nm<br />
Solvent: Mobile Phase<br />
Mobile Phase: 20 mM Ammonium Acetate, pH 4.5: Acetonitrile (85:15, v/v)<br />
Flow Rate: 1.0 mL/min.<br />
Temperature: 30 °C<br />
Injection: 5 μL<br />
Part No.<br />
N9303618<br />
Analgesic Acetaminophen and Narcotic Analgesics<br />
Peak Identification<br />
U.<br />
1.<br />
2.<br />
3.<br />
4.<br />
5.<br />
* (Ret. Time (min.), Tailing, Resolution)<br />
Part No.<br />
N9303561<br />
Conc.<br />
(μg/mL)<br />
Unknown<br />
unknown<br />
(3.1, NA, NA)*<br />
1<br />
2<br />
Morphine Sulfate 204<br />
(3.3, 1.0, 1.8)*<br />
Acetaminophen 92<br />
3<br />
(5.0, 1.1, 14.1)*<br />
4<br />
Codeine Phosphate 216<br />
(5.5, 1.4, 2.6)*<br />
5<br />
Oxycodone HCl 206<br />
U<br />
(7.5, 1.4, 8.5)*<br />
Hydrocodone Bitartrate 218 0 1 2 3 4 5 6 7 8 9<br />
(8.9, 1.4, 5.0)*<br />
TIME (MIN.)<br />
CHROMATOGRAPHIC CONDITIONS<br />
Column: Brownlee Validated C18<br />
Dimensions: 250 x 4.6 mm, 5 μm, 100 Å<br />
Sample: Raw Material Mix<br />
Detection: UV @ 235 nm<br />
Solvent: Mobile Phase<br />
Mobile Phase: A: 10 mm Potassium Phosphate, pH 2.8<br />
B: Acetonitrile:Methanol (90:10 v/v) (85A:15B, v/v)<br />
Flow Rate: 1.0 mL/min.<br />
Temperature: 27 °C<br />
Injection: 4.0 μL<br />
1<br />
2<br />
3<br />
Conventional Column Applications<br />
4<br />
Antiarrhythmic Atenolol<br />
Peak Identification<br />
1.<br />
2.<br />
1<br />
Pharmaceutical<br />
0 2 4 6 8 10 12<br />
TIME (MIN.)<br />
CHROMATOGRAPHIC CONDITIONS<br />
Column: Brownlee Choice Basix<br />
Dimensions: 150 x 4.6 mm, 5 μm, 60 Å<br />
Conc.: 1 mg/mL<br />
Detection: UV @ 225 nm<br />
Solvent: Water:Methanol (7:3, v/v)<br />
Mobile Phase: Acetonitrile: 20 mM Ammonium Acetate, pH 4.5 (80:20, v/v)<br />
Flow Rate: 1.2 mL/min.<br />
Temperature: 25 °C<br />
Injection: 1 μL<br />
Part No.<br />
Uracil (marker)<br />
Atenolol<br />
N9303618<br />
Antiarrhythmic Calcium Channel Blockers<br />
Peak Identification<br />
1.<br />
2.<br />
3.<br />
4.<br />
5.<br />
2<br />
CHROMATOGRAPHIC CONDITIONS<br />
Column: Brownlee Validated Cyano<br />
Dimensions: 150 x 4.6 mm, 5 μm, 100 Å<br />
Conc.: 100 mg/mL<br />
Detection: 235 nm<br />
Solvent: Acetonitrile:Water (1:1)<br />
Mobile Phase: 20 mM Potassium Phosphate Monobasic, pH 3.0:<br />
Acetonitrile (70:30, v/v)<br />
Flow Rate: 1.2 mL/min.<br />
Temperature: 30 °C (±1 °C)<br />
Injection: 5 μL<br />
Part No.<br />
Diltiazem<br />
Nifedipine Impurity<br />
Verapamil<br />
Nifedipine<br />
Nicardipine<br />
0 1 2 3 4 5 6 7 8 9<br />
TIME (MIN.)<br />
N9303575<br />
1<br />
2<br />
3<br />
4<br />
5<br />
Conventional Column Applications Liquid Chromatography<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
305
Conventional Column Applications<br />
Pharmaceutical<br />
Liquid Chromatography Conventional Column Applications<br />
Antibiotic Amoxicillin<br />
Peak Identification<br />
1.<br />
CHROMATOGRAPHIC CONDITIONS<br />
Column: Brownlee Validated IBD<br />
Dimensions: 150 x 4.6 mm, 5 μm, 100 Å<br />
Conc.: 1.5 mg/mL<br />
Detection: UV @ 270 nm<br />
Solvent: Acetonitrile:Water (10:90, v/v)<br />
Mobile Phase: 10 mM Ammonium Formate, pH 2.5: Acetonitrile (95:5, v/v)<br />
Flow Rate: 1.2 mL/min.<br />
Temperature: 30 °C<br />
Injection: 5 μL<br />
Part No.<br />
Amoxicillin<br />
N9303582<br />
0 1 2 3 4 5 6<br />
TIME (MIN.)<br />
Antibiotic Sulfamethoxazole, Trimethoprim,<br />
and Naphthoate<br />
Peak Identification<br />
1.<br />
2.<br />
3.<br />
Part No.<br />
Trimethoprim<br />
Sulfamethoxazole<br />
Naphthoate<br />
0 2 4 6 8 10 12 14<br />
TIME (MIN.)<br />
CHROMATOGRAPHIC CONDITIONS<br />
Column: Brownlee Choice C18<br />
Dimensions: 150 x 4.6 mm, 5 μm, 60 Å<br />
Conc.: 100 μg/mL<br />
Detection: UV @ 220 nm<br />
Solvent: Water:Methanol (1:1, v/v)<br />
Mobile Phase: 10 mM Ammonium Formate, pH to 3.0<br />
with Formic Acid: Methanol (50:50, v/v)<br />
Flow Rate: 1.0 mL/min.<br />
Temperature: Ambient<br />
Injection: 10 μL<br />
N9303628<br />
1<br />
2<br />
3<br />
1<br />
Antidepressants (Tricyclic)<br />
Peak Identification<br />
1.<br />
2.<br />
3.<br />
4.<br />
5.<br />
6.<br />
7.<br />
CHROMATOGRAPHIC CONDITIONS<br />
Column: Brownlee Choice Basix<br />
Dimensions: 150 x 4.6 mm, 5 μm, 60 Å<br />
Conc.: 100 μg/mL<br />
Detection: UV @ 254 nm<br />
Solvent: Mobile Phase<br />
Mobile Phase: Acetonitrile: 50 mM KH 2 PO 4 pH3: Methanol (60:25:15, v/v)<br />
Flow Rate: 1.2 mL/min.<br />
Temperature: 30 °C<br />
Injection: 10 μL<br />
Part No.<br />
Doxepin<br />
Nordoxepin<br />
Amitriptyline<br />
Imipramine<br />
Desimipramine<br />
Nortriptyline<br />
Protriptyline<br />
Corticosteroids<br />
Part No.<br />
1<br />
1 2<br />
3<br />
4<br />
0 1 2 3 4 5 6 7 8 9<br />
TIME (MIN.)<br />
N9303618<br />
N9303628<br />
Peak Identification<br />
1.<br />
2.<br />
3.<br />
2 3<br />
0 1 2 3 4<br />
TIME (MIN.)<br />
CHROMATOGRAPHIC CONDITIONS<br />
Column: Brownlee Choice C18<br />
Dimensions: 150 x 4.6 mm, 5 μm, 60 Å<br />
Conc.: 100 μg/mL each<br />
Detection: UV @ 254 nm<br />
Solvent: Water:Acetonitrile (1:1)<br />
Mobile Phase: Water:Methanol (50:50, v/v)<br />
Flow Rate: 1.0 mL/min.<br />
Temperature: Ambient<br />
Injection: 5 μL<br />
5<br />
6<br />
7<br />
Uracil<br />
Corticosterone<br />
Deoxycorticosterone<br />
306
Corticosteroids Standards<br />
Peak Identification<br />
1.<br />
2.<br />
3.<br />
4.<br />
5.<br />
6.<br />
CHROMATOGRAPHIC CONDITIONS<br />
Column: Brownlee Validated C18<br />
Dimensions: 150 x 4.6 mm, 5 μm, 100 Å<br />
Conc.: 100 μg/mL<br />
Detection: UV @ 220 nm<br />
Solvent: Mobile Phase<br />
Mobile Phase: Water:Methanol (30:70, v/v)<br />
Flow Rate: 1.0 mL/min.<br />
Temperature: 30 °C<br />
Injection: 5 μL<br />
Part No.<br />
Uracil<br />
Triamcinolone<br />
Hydrocortisone<br />
Dexamethasone<br />
Corticosterone<br />
Deoxycorticosterone<br />
N9303558<br />
1<br />
0 1 2 3 4 5 6<br />
TIME (MIN.)<br />
Narcotic Analgesic Hydrocodone Bitartrate by USP 25<br />
Impurities resolved<br />
from primary peak.<br />
0 1 2 3 4<br />
TIME (MIN.)<br />
2<br />
0 1 2 3 4<br />
TIME (MIN.)<br />
3<br />
4<br />
5<br />
Conventional Column Applications<br />
6<br />
1<br />
Hormones ß-Estradiol, Norethindrone,<br />
and Ethynyl Estradiol<br />
Peak Identification<br />
1.<br />
2.<br />
3.<br />
CHROMATOGRAPHIC CONDITIONS<br />
Column: Brownlee Validated C18<br />
Dimensions: 150 x 4.6 mm, 5 μm, 100 Å<br />
Conc.: 333 μg/mL<br />
Detection: UV @ 230 nm<br />
Solvent: Acetonitrile:Water (80:20, v/v)<br />
Mobile Phase: 10 mM Ammonium Formate, pH 3.0:<br />
Acetonitrile (60:40, v/v)<br />
Flow Rate: 1.0 mL/min.<br />
Temperature: 30 °C<br />
Injection: 10 μL<br />
Part No.<br />
ß-Estradiol<br />
Norethindrone<br />
Ethynyl Estradiol<br />
N9303558<br />
Pharmaceutical<br />
0 2 4 6 8 10 12 14<br />
TIME (MIN.)<br />
Ret. Time Inj. %<br />
Peak Identification (min.) RSD (n=5)<br />
1.<br />
Hydrocodone Bitartrate 3.1 0.37%<br />
CHROMATOGRAPHIC CONDITIONS<br />
Column: Brownlee Analytical Silica<br />
Dimensions: 250 x 4.6 mm, 5 μm, 100 Å<br />
Sample: Assay Standard<br />
Conc.: 1 μg/mL<br />
Detection: UV @ 280 nm<br />
Solvent: Mobile Phase<br />
Mobile Phase: A: 800 mM Acetonitrile; 4 mL<br />
Water; 1 mL Diethylamine<br />
B: Methanol (55A:45B, v/v)<br />
Flow Rate: 1.5 mL/min.<br />
Temperature: 27 °C<br />
Injection: 20 μL<br />
Part No.<br />
N9303526<br />
1<br />
2<br />
3<br />
Conventional Column Applications Liquid Chromatography<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
307
Conventional Columns<br />
Brownlee Analytical Conventional Columns<br />
Liquid Chromatography Conventional Columns<br />
Brownlee Analytical Amino<br />
Ideal column for mono and disaccharide analyses. Most<br />
popular amino-based stationary phase. Routine analysis of<br />
simple sugars, using isocratic elution and a refractive index<br />
detector or an evaporative light scattering detector.<br />
pH range: 2.5 to 7.5 - Temperature limit: 80 °C<br />
Pore size: 110 Å - Carbon load: 2% - End Cap: No<br />
Length<br />
Particle<br />
Phase mm ID mm Size μm Part No. Each (€)<br />
Amino 50 4.6 3 N9303502 356<br />
Amino 100 4.6 3 N9303500 381<br />
Amino 150 4.6 3 N9303501 407<br />
Amino 50 4.6 5 N9303506 343<br />
Amino 100 4.6 5 N9303503 369<br />
Amino 150 4.6 5 N9303504 381<br />
Amino 250 4.6 5 N9303505 433<br />
Brownlee Analytical C8<br />
Shorter retention times for hydrophobic compounds.<br />
Reliable performance with symmetrical peak shapes<br />
for neutral to acidic compounds.<br />
pH range: 2.5 to 7.5 - Temperature limit: 80 °C - Pore size: 100 Å<br />
Carbon load: 7% - End Cap: Yes<br />
Length<br />
Particle<br />
Phase mm ID mm Size μm Part No. Each (€)<br />
C8 30 4.6 5 N9303521 326<br />
C8 100 4.6 5 N9303515 369<br />
C8 150 4.0 5 N9303516 389<br />
C8 150 4.6 5 N9303517 389<br />
C8 200 4.6 5 N9303518 407<br />
C8 250 4.0 5 N9303519 433<br />
C8 250 4.6 5 N9303520 433<br />
Brownlee Analytical C18<br />
Suitable for a wide range of acidic to neutral hydrophobic<br />
compounds. Excellent all purpose column.<br />
pH range: 2.5 to 7.5 - Temperature limit: 80 °C<br />
Pore size: 110 Å - Carbon load: 13% - End Cap: Yes<br />
Length<br />
Particle<br />
Phase mm ID mm Size μm Part No. Each (€)<br />
C18 30 4.6 3 N9303509 339<br />
C18 50 4.6 3 N9303510 356<br />
C18 100 4.6 3 N9303507 381<br />
C18 150 4.6 3 N9303508 407<br />
C18 100 4.0 5 N9303511 369<br />
C18 100 4.6 5 N9303512 369<br />
C18 150 4.6 5 N9303513 389<br />
C18 250 4.6 5 N9303514 433<br />
Brownlee Analytical Cyano<br />
Suitable for analyses of a wide range of compounds<br />
from acidic through slightly basic. Highly base-deactivated<br />
spherical silica.<br />
pH range: 2.5 to 7.5 - Temperature limit: 80 °C - Pore size: 110 Å<br />
Carbon load: 4% - End Cap: Yes<br />
Length<br />
Particle<br />
Phase mm ID mm Size μm Part No. Each (€)<br />
Cyano 150 4.6 5 N9303522 381<br />
Cyano 250 4.6 5 N9303523 433<br />
Brownlee Analytical PAH<br />
Specifically designed for challenging analyses of<br />
polynuclear aromatic hydrocarbons.<br />
pH range: 2.5 to 7.5 - Temperature limit: 80 °C - Pore size: 110 Å<br />
End Cap: Yes<br />
Length<br />
Particle<br />
Phase mm ID mm Size μm Part No. Each (€)<br />
PAH 100 4.6 5 N9303527 353<br />
PAH 150 3.2 5 N9303430 517<br />
PAH 150 4.6 5 N9303529 521<br />
PAH 200 4.6 5 N9303528 534<br />
PAH 250 2.1 5 N9303530 534<br />
PAH 250 4.6 5 N9303531 534<br />
Brownlee Analytical Phenyl<br />
Unique selectivity especially for aromatic compounds.<br />
pH range: 2.5 to 7.5 - Temperature limit: 80 °C - Carbon load: 6%<br />
Pore size: 110 Å - End Cap: Yes<br />
Length<br />
Particle<br />
Phase mm ID mm Size μm Part No. Each (€)<br />
Phenyl 150 4.6 5 N9303524 389<br />
Brownlee Analytical Silica<br />
Good general purpose packing for normal phase separations.<br />
pH range: 2.5 to 7.5 - Temperature limit: 80 °C - Pore size: 110 Å<br />
End Cap: No<br />
Length<br />
Particle<br />
Phase mm ID mm Size μm Part No. Each (€)<br />
Silica 150 4.6 5 N9303525 389<br />
Silica 250 4.6 5 N9303526 433<br />
308
Conventional Columns<br />
Brownlee Aquapore and Bio Conventional Columns<br />
Brownlee Aquapore AX-300<br />
Brownlee Bio C8<br />
Used for Ion Exchange chromatography.<br />
Pore Size: 300 Å<br />
Length<br />
Particle<br />
Phase mm ID mm Size μm Part No. Each (€)<br />
AX-300 250 4.6 7 07120040 1312<br />
Brownlee Aquapore Octyl C8<br />
Used for Reversed Phase chromatography.<br />
Pore Size: 300 Å<br />
Length<br />
Particle<br />
Phase mm ID mm Size μm Part No. Each (€)<br />
C8 100 1.0 7 07120096 547<br />
C8 250 1.0 7 07120097 547<br />
C8 250 4.6 7 07120033 738<br />
Brownlee Aquapore ODS C18<br />
Silica-based support suitable for the separation of large<br />
biopolymers. Microbore columns increase sensitivity,<br />
reduce sample size, and have better compatibility<br />
with LC/MS interfaces.<br />
Pore Size: 300 Å<br />
Length<br />
Particle<br />
Phase mm ID mm Size μm Part No. Each (€)<br />
C18 100 1.0 7 07120099 547<br />
C18 250 4.6 7 07120073 636<br />
Wide-pore HPLC Column. High proportion of pore/surface<br />
area available for large molecule separations.<br />
Pore Size: 300 Å - Carbon Load: 6% - End Cap: Yes<br />
Length<br />
Particle<br />
Phase mm ID mm Size μm Part No. Each (€)<br />
C8 50 2.1 5 N9303664 433<br />
C8 50 4.6 5 N9303665 433<br />
C8 100 2.1 5 N9303656 471<br />
C8 100 4.6 5 N9303657 471<br />
C8 150 2.1 5 N9303658 508<br />
C8 150 4.6 5 N9303659 508<br />
C8 200 2.1 5 N9303660 547<br />
C8 200 4.6 5 N9303661 547<br />
C8 250 2.1 5 N9303662 580<br />
C8 250 4.6 5 N9303663 580<br />
Brownlee Bio C18<br />
Excellent for separating peptides or proteins.<br />
Wide-pore HPLC Column.<br />
Pore Size: 300 Å - Carbon Load: 6% - End Cap: Yes<br />
Length<br />
Particle<br />
Phase mm ID mm Size μm Part No. Each (€)<br />
C18 50 2.1 5 N9303654 433<br />
C18 50 4.6 5 N9303655 433<br />
C18 100 2.1 5 N9303646 471<br />
C18 100 4.6 5 N9303647 471<br />
C18 150 2.1 5 N9303648 508<br />
C18 150 4.6 5 N9303649 508<br />
C18 200 2.1 5 N9303650 547<br />
C18 200 4.6 5 N9303651 547<br />
C18 250 2.1 5 N9303652 580<br />
C18 250 4.6 5 N9303653 580<br />
Conventional Columns Liquid Chromatography<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
309
Conventional Columns<br />
Brownlee CHOICE Conventional Columns<br />
Liquid Chromatography Conventional Columns<br />
Brownlee CHOICE Basix<br />
Excellent choice for analytes containing amine<br />
group functionality.<br />
pH range: 2.5 to 7.5 - Temperature limit: 80 °C -<br />
Pore Size: 60 Å - Carbon Load: 12% - End Cap: Yes<br />
Length<br />
Particle<br />
Phase mm ID mm Size μm Part No. Each (€)<br />
Basix 30 2.1 3 N9303610 471<br />
Basix 50 2.1 3 N9303611 471<br />
Basix 100 2.1 3 N9303608 508<br />
Basix 100 4.6 3 N9303609 508<br />
Basix 150 4.6 3 N9303612 547<br />
Basix 50 2.1 5 N9303615 433<br />
Basix 50 4.6 5 N9303616 433<br />
Basix 100 2.1 5 N9303613 471<br />
Basix 100 4.6 5 N9303614 471<br />
Basix 150 2.1 5 N9303617 504<br />
Basix 150 4.6 5 N9303618 508<br />
Basix 250 4.6 5 N9303619 580<br />
Brownlee CHOICE C18<br />
Excellent choice for LC/MS. Highly retentive phase for<br />
hydrophobic and slightly polar analytes.<br />
pH range: 2.5 to 7.5 - Temperature limit: 80 °C -<br />
Pore Size: 60 Å - Carbon Load: 27% - End Cap: Yes<br />
Length<br />
Particle<br />
Phase mm ID mm Size μm Part No. Each (€)<br />
C18 50 2.1 3 N9303622 471<br />
C18 50 4.6 3 N9303623 471<br />
C18 100 2.1 3 N9303620 508<br />
C18 100 4.6 3 N9303621 508<br />
C18 150 4.6 3 N9303624 547<br />
C18 50 2.1 5 N9303626 433<br />
C18 100 2.1 5 N9303625 471<br />
C18 150 2.1 5 N9303627 508<br />
C18 150 4.6 5 N9303628 508<br />
C18 250 2.1 5 N9303629 580<br />
C18 250 4.6 5 N9303630 580<br />
Brownlee CHOICE Organic Acids<br />
Enhanced retention and selectivity for polar organic acids.<br />
Retention is stable and reproducible even with 100%<br />
aqueous mobile phase specified in the AOAC method.<br />
pH range: 2.5 to 7.5 - Temperature limit: 80 °C -<br />
Pore Size: 60 Å - End Cap: No<br />
Length<br />
Particle<br />
Phase mm ID mm Size μm Part No. Each (€)<br />
Organic Acids 150 4.6 5 N9303631 721<br />
Organic Acids 250 2.1 5 N9303632 598<br />
Organic Acids 250 4.6 5 N9303633 764<br />
Organic Acids 300 4.6 5 N9303634 790<br />
Brownlee CHOICE Propyl<br />
Highly retentive for basic analytes. Excellent separation of<br />
nucleosides, nucleotides, purines, pyrimidines halogenated<br />
compounds, beta blockers and tricyclic antidepressants.<br />
pH range: 2.5 to 7.5 - Temperature limit: 80 °C -<br />
Pore Size: 60 Å - Carbon Load: 17% - End Cap: Yes<br />
Length<br />
Particle<br />
Phase mm ID mm Size μm Part No. Each (€)<br />
PFP Propyl 50 2.1 3 N9303636 483<br />
PFP Propyl 50 4.6 3 N9303637 483<br />
PFP Propyl 100 4.6 3 N9303635 521<br />
PFP Propyl 30 2.1 5 N9303640 453<br />
PFP Propyl 50 2.1 5 N9303641 453<br />
PFP Propyl 50 4.6 5 N9303642 453<br />
PFP Propyl 100 2.1 5 N9303638 483<br />
PFP Propyl 100 4.6 5 N9303639 483<br />
PFP Propyl 150 2.1 5 N9303643 521<br />
PFP Propyl 150 4.6 5 N9303644 521<br />
PFP Propyl 250 4.6 5 N9303645 598<br />
310
Conventional Columns<br />
Brownlee Spheri-5 and Validated Conventional Columns<br />
Brownlee Spheri-5 ®<br />
Small pore silica-based sorbent for separating small<br />
molecules both non-functional and polyfunctional<br />
C8 and C18 are available.<br />
Length: 250 mm - ID: 4.6 mm - Pore Size: 80 Å<br />
Length<br />
Particle<br />
Phase mm ID mm Size μm Part No. Each (€)<br />
C2 250 4.6 10 07120005 483<br />
C8 250 4.6 5 07120012 483<br />
C18 250 4.6 5 07120016 573<br />
C18 250 4.6 10 07120001 483<br />
C18 ODS 250 4.6 5 07120019 483<br />
Silica 250 4.6 5 07120023 611<br />
Brownlee Validated TM Amino<br />
Good for normal phase analytes of mono- and disaccharides<br />
or similar compounds.<br />
pH range: 2.5 to 7.5 - Temperature limit: 80 °C -<br />
Particle Size: 5 μm - Pore Size: 100 Å - Carbon Load: 2%<br />
Length<br />
Particle<br />
Phase mm ID mm Size μm Part No. Each (€)<br />
Amino 100 2.1 5 N9303532 471<br />
Amino 150 2.1 5 N9303533 508<br />
Amino 150 4.6 5 N9303534 508<br />
Amino 200 4.6 5 N9303535 547<br />
Amino 250 4.6 5 N9303536 580<br />
Brownlee Validated Aqueous C18<br />
Highly base deactivated. Compatible with highly aqueous<br />
mobile phases.<br />
pH range: 2.5 to 7.5 - Temperature limit: 80 °C -<br />
Pore Size: 100 Å - Carbon Load: 15% - End Cap: No<br />
Length<br />
Particle<br />
Phase mm ID mm Size μm Part No. Each (€)<br />
Aqueous C18 30 2.1 3 N9303540 483<br />
Aqueous C18 50 2.1 3 N9303541 483<br />
Aqueous C18 50 4.6 3 N9303542 483<br />
Aqueous C18 100 2.1 3 N9303537 521<br />
Aqueous C18 100 4.6 3 N9303538 521<br />
Aqueous C18 150 2.1 3 N9303539 547<br />
Aqueous C18 30 4.6 5 N9303550 453<br />
Aqueous C18 100 2.1 5 N9303543 483<br />
Aqueous C18 100 4.6 5 N9303544 483<br />
Aqueous C18 150 2.1 5 N9303545 521<br />
Aqueous C18 150 4.6 5 N9303546 521<br />
Aqueous C18 200 4.6 5 N9303547 560<br />
Aqueous C18 250 2.1 5 N9303548 598<br />
Aqueous C18 250 4.6 5 N9303549 598<br />
Brownlee Validated C1<br />
Least retentive reversed phase hydrocarbon packing.<br />
pH range: 2.5 to 7.5 - Temperature limit: 80 °C -<br />
Pore Size: 100 Å - Carbon Load: 5% - End Cap: No<br />
Length<br />
Particle<br />
Phase mm ID mm Size μm Part No. Each (€)<br />
C1 150 4.6 5 N9303718 500<br />
C1 250 4.6 5 N9303719 571<br />
Brownlee Validated C4<br />
High bonding coverage and base deactivation. Less retention<br />
than C18 or C8 phases.<br />
pH range: 2.5 to 7.5 - Temperature limit: 80 °C -<br />
Pore Size: 100 Å - Carbon Load: 9% - End Cap: Yes<br />
Length<br />
Particle<br />
Phase mm ID mm Size μm Part No. Each (€)<br />
C4 150 4.6 5 N9303720 500<br />
C4 250 4.6 5 N9303721 571<br />
Brownlee Validated C8<br />
Retentive, high purity base-deactivated reversed phase packing.<br />
pH range: 2.5 to 7.5 - Temperature limit: 80 °C -<br />
Pore Size: 80 Å - Carbon Load: 12% - End Cap: Yes<br />
Length<br />
Particle<br />
Phase mm ID mm Size μm Part No. Each (€)<br />
C8 100 2.1 5 N9303564 471<br />
C8 100 4.6 5 N9303565 471<br />
C8 150 2.1 5 N9303566 508<br />
C8 150 4.6 5 N9303567 508<br />
C8 250 4.6 5 N9303568 580<br />
Brownlee Validated C18<br />
Excellent general purpose phase column.<br />
Retentive high purity packing.<br />
pH range: 2.5 to 7.5 - Temperature limit: 80 °C -<br />
Pore Size: 100 Å - Carbon Load: 20% - End Cap: Yes<br />
Length<br />
Particle<br />
Phase mm ID mm Size μm Part No. Each (€)<br />
C18 100 2.1 3 N9303551 508<br />
C18 100 4.6 3 N9303552 508<br />
C18 50 2.1 5 N9303562 433<br />
C18 50 4.6 5 N9303563 433<br />
C18 100 2.1 5 N9303553 471<br />
C18 100 4.6 5 N9303554 471<br />
C18 150 2.1 5 N9303556 508<br />
C18 150 4.0 5 N9303557 508<br />
C18 150 4.6 5 N9303558 508<br />
C18 200 4.6 5 N9303559 547<br />
C18 250 2.1 5 N9303560 580<br />
C18 250 4.6 5 N9303561 580<br />
Conventional Columns Liquid Chromatography<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
311
Conventional Columns<br />
Brownlee Validated Conventional Columns<br />
Liquid Chromatography Conventional Columns<br />
Brownlee Validated TM Carbamate<br />
A unique stationary phase bonded to a 3μm silica<br />
specifically designed for carbamate analysis. This column<br />
is compatible with fluorescence or LC/MS detection.<br />
Validated Carbamate column has much faster analysis,<br />
which will significantly reduce solvent usage.<br />
pH range: 2.5 to 7.5 - Temperature limit: 80 °C - Pore Size: 100 Å<br />
Length<br />
Particle<br />
Phase mm ID mm Size μm Part No. Each (€)<br />
Carbamate 50 4.6 3 N9303570 644<br />
Carbamate 100 4.6 3 N9303569 644<br />
Carbamate 250 4.6 3 N9303571 611<br />
Brownlee Validated Cyano<br />
High purity Cyano phase with few silanol sites. Less sensitive<br />
to small amounts of water present in the mobile phase.<br />
pH range: 2.5 to 7.5 - Temperature limit: 80 °C -<br />
Pore Size: 100 Å - Carbon Load: 10% - End Cap: Yes<br />
Length<br />
Particle<br />
Phase mm ID mm Size μm Part No. Each (€)<br />
Cyano 30 4.6 5 N9303578 433<br />
Cyano 100 2.1 5 N9303572 471<br />
Cyano 100 4.6 5 N9303573 471<br />
Cyano 150 2.1 5 N9303574 508<br />
Cyano 150 4.6 5 N9303575 508<br />
Cyano 200 4.6 5 N9303576 547<br />
Cyano 250 4.6 5 N9303577 580<br />
Brownlee Validated IBD<br />
Unique selectivity and a high level of base-deactivation.<br />
Reduces or eliminates the need for mobile phase additives.<br />
pH range: 2.5 to 7.5 - Temperature limit: 80 °C -<br />
Pore Size: 100 Å - Carbon Load: 12% - End Cap: No<br />
Length<br />
Particle<br />
Phase mm ID mm Size μm Part No. Each (€)<br />
IBD 30 4.6 3 N9303594 433<br />
IBD 50 2.1 3 N9303595 433<br />
IBD 50 4.6 3 N9303596 433<br />
IBD 100 2.1 3 N9303590 521<br />
IBD 100 4.6 3 N9303591 521<br />
IBD 150 2.1 3 N9303592 547<br />
IBD 150 4.6 3 N9303593 547<br />
IBD 30 1.0 5 N9303585 478<br />
IBD 30 2.1 5 N9303586 453<br />
IBD 30 4.6 5 N9303587 453<br />
Length<br />
Particle<br />
Phase mm ID mm Size μm Part No. Each (€)<br />
IBD 50 2.1 5 N9303588 453<br />
IBD 50 4.6 5 N9303589 453<br />
IBD 100 2.1 5 N9303579 433<br />
IBD 100 4.6 5 N9303580 433<br />
IBD 150 2.1 5 N9303581 521<br />
IBD 150 4.6 5 N9303582 521<br />
IBD 200 4.6 5 N9303583 560<br />
IBD 250 4.6 5 N9303584 598<br />
Brownlee Validated PFP<br />
Unique selectivity for compounds containing<br />
organohalogens or other basic functional groups.<br />
pH range: 2.5 to 7.5 - Temperature limit: 80 °C -<br />
Pore Size: 100 Å - Carbon Load: 7% - End Cap: Yes<br />
Length<br />
Particle<br />
Phase mm ID mm Size μm Part No. Each (€)<br />
PFP 50 2.1 5 N9303601 453<br />
PFP 100 4.6 5 N9303597 433<br />
PFP 150 2.1 5 N9303598 521<br />
PFP 150 4.6 5 N9303599 521<br />
PFP 250 4.6 5 N9303600 598<br />
Brownlee Validated Phenyl<br />
High purity, highly retentive base-deactivated phase,<br />
especially designed for aromatic analytes.<br />
pH range: 2.5 to 7.5 - Temperature limit: 80 °C -<br />
Pore Size: 100 Å - Carbon Load: 10% - End Cap: Yes<br />
Length<br />
Particle<br />
Phase mm ID mm Size μm Part No. Each (€)<br />
Phenyl 50 1.0 3 N9303604 496<br />
Phenyl 100 2.1 3 N9303602 508<br />
Phenyl 100 4.6 3 N9303603 508<br />
Phenyl 150 2.1 5 N9303605 508<br />
Phenyl 150 4.6 5 N9303606 508<br />
Phenyl 250 4.6 5 N9303607 580<br />
312
Conventional Columns<br />
Guard Cartridges and Accessories<br />
Guard Cartridge Accessories<br />
Description Part No. Each (€)<br />
10 mm guard cartridge holder with filter N9303713 139<br />
10 mm guard cartridge holder without filter N9303712 114<br />
High pressure filter N9303711 114<br />
Peek tip standard fittings N9303714 17<br />
Replacement cap frits 2.0 mm, 2.0 μm N9303717 44<br />
Replacement cap frits 4.0 mm, 0.5 μm N9303716 44<br />
Replacement cap frits 4.0 mm, 2.0 μm N9303715 37<br />
Guard Cartridges Brownlee Analytical<br />
Pkg: 3<br />
Length<br />
Particle<br />
Phase mm ID mm Size μm Part No. Each (€)<br />
Amino 10 2.1 5 N9303674 185<br />
Amino 10 4.0 5 N9303675 185<br />
C18 10 2.1 5 N9303676 185<br />
C18 10 4.0 5 N9303677 185<br />
C8 10 2.1 5 N9303678 185<br />
C8 10 4.0 5 N9303679 185<br />
Cyano 10 2.1 5 N9303680 185<br />
Cyano 10 4.0 5 N9303681 185<br />
PAH 10 2.1 5 N9303682 185<br />
PAH 10 4.0 5 N9303683 185<br />
Phenyl 10 2.1 5 N9303684 185<br />
Phenyl 10 4.0 5 N9303685 185<br />
Silica 10 2.1 5 N9303686 185<br />
Silica 10 4.0 5 N9303687 185<br />
Guard Cartridges Brownlee Bio<br />
Pore Size: 300 Å - Pkg: 3<br />
Length<br />
Particle<br />
Phase mm ID mm Size μm Part No. Each (€)<br />
C18 10 2.1 5 N9303708 185<br />
C18 10 4.0 5 N9303707 185<br />
C8 10 2.1 5 N9303709 185<br />
C8 10 4.0 5 N9303710 185<br />
Guard Cartridges Brownlee CHOICE<br />
Pore Size: 60 Å - Pkg: 3<br />
Length<br />
Particle<br />
Phase mm ID mm Size μm Part No. Each (€)<br />
Basix 10 2.1 5 N9303666 185<br />
Basix 10 4.0 5 N9303667 185<br />
C18 10 2.1 5 N9303668 185<br />
C18 10 4.0 5 N9303669 185<br />
Organic Acids 10 2.1 5 N9303670 185<br />
Organic Acids 10 4.0 5 N9303671 185<br />
PFP Propyl 10 2.1 5 N9303672 185<br />
PFP Propyl 10 4.0 5 N9303673 185<br />
Guard Cartridges Brownlee Validated<br />
Pore Size: 100 Å - Pkg: 3<br />
Length<br />
Particle<br />
Phase mm ID mm Size μm Part No. Each (€)<br />
Amino 10 2.1 5 N9303688 185<br />
Amino 10 4.0 5 N9303689 185<br />
Aqueous C18 10 2.1 5 N9303690 185<br />
Aqueous C18 10 4.0 5 N9303691 185<br />
C1 10 4.0 5 N9303722 181<br />
C4 10 4.0 5 N9303723 181<br />
C8 10 2.1 5 N9303695 185<br />
C8 10 4.0 5 N9303696 185<br />
C18 10 2.1 5 N9303693 185<br />
C18 10 4.0 5 N9303694 185<br />
C18 10 4.0 10 N9303692 185<br />
Carbamate 10 2.1 5 N9303697 185<br />
Carbamate 10 4.0 5 N9303698 185<br />
Cyano 10 2.1 5 N9303699 185<br />
Cyano 10 4.0 5 N9303700 185<br />
IBD 10 2.1 5 N9303701 185<br />
IBD 10 4.0 5 N9303702 185<br />
PFP 10 2.1 5 N9303703 185<br />
PFP 10 4.0 5 N9303704 185<br />
Phenyl 10 2.1 5 N9303705 185<br />
Phenyl 10 4.0 5 N9303706 185<br />
Conventional Columns Liquid Chromatography<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
313
Detectors<br />
Diode Array Detector<br />
LC-135C/235 Detector<br />
Series 200 Diode Array Detector<br />
Backpressure Regulator<br />
Adjustable from 15-59 psi,<br />
stainless steel.<br />
Part No. Each (€)<br />
09907126 236<br />
Backpressure Regulator<br />
Adjustable from 15-59 psi,<br />
stainless steel.<br />
Part No. Each (€)<br />
09907126 236<br />
Detector/Lamp<br />
Flowcell Assembly<br />
Part No. Each (€)<br />
N2351285 504<br />
Part No. Each (€)<br />
Detector/Lamps<br />
Description Part No. Each (€)<br />
Deuterium Lamp (Phase 2) N2922046 523<br />
Standard Deuterium Lamp (Phase 1) N2922010 899<br />
Tungsten Source N2922011 143<br />
8.0 μL titanium.<br />
N2350211 1683<br />
Flowcells<br />
Liquid Chromatography Detectors<br />
Operator’s Manual<br />
Maintenance Kit<br />
Includes: test flowcell, D2 lamp,<br />
cell lens, and backpressure valve.<br />
Series 200 Photo Diode Array Detector<br />
Part No. Each (€)<br />
09938727 159<br />
Part No. Each (€)<br />
N2350014 2270<br />
Description Part No. Each (€)<br />
Flowcell Assembly, PEEK N2922029 1492<br />
12 μL, 10 mm path<br />
Low Volume Flowcell Assembly, Stainless Steel N2922030 2168<br />
5.0 μL, 4.5 mm path<br />
Standard Flowcell Assembly, Stainless Steel N2922028 2844<br />
12.0 μL, 10.0 mm path<br />
Operator’s Manual<br />
Part No.<br />
Each (€)<br />
09938914 99<br />
314
Detectors<br />
Fluorescence and Refractive Index (RI) Detector<br />
Series 200 Fluorescence Detector<br />
Combining Sensitivity and Specificity<br />
The Series 200 Fluorescence Detector provides the highest<br />
sensitivities for diverse LC analyses such as serum and<br />
plasma in pharmaceutical research, environmental analysis<br />
of pollutants, and food and beverage products. The major<br />
benefit afforded by fluorescence detection is the inherent<br />
sensitivity of the technique coupled with high specificity.<br />
The Series 200 Detector provides signal-to-noise ratio of<br />
>300:1 for trace analysis using a 150 W Zenon source.<br />
Maximum analysis flexibility is provided by full wavelength<br />
programming (Ex 200-850 nm, Em 250-900 nm), background<br />
subtraction, and spectrum memory.<br />
The major benefit afforded by fluorescence detection<br />
is the inherent high sensitivity of the technique coupled<br />
with outstanding specificity – given that relatively few<br />
molecules natively fluoresce. Therefore, the specific<br />
excitation and emission wavelength profile aids in the<br />
characterization of individual components. The Series 200<br />
Fluorescence Detector delivers the outstanding performance<br />
and reliability you’ve come to expect from PerkinElmer –<br />
backed by our unrivaled global support network.<br />
Series 200 Fluorescence Detector<br />
100/120/220/240 VAC, 50/60 Hz.<br />
Series 200/200A Detector Lamps<br />
Xenon lamp for Series 200 Detector.<br />
Part No.<br />
Each (€)<br />
N2922006 8800<br />
Part No.<br />
Each (€)<br />
N2922082 823<br />
Series 200a Refractive Index Detector<br />
Series 200a RI Detector<br />
The Series 200a Refractive Index (RI) Detector is a highly<br />
stable and sensitive LC and GPC detector. The Series 200a is<br />
well suited for compounds that do not have high absorptivity<br />
in the UV range, such as polymers, sugars, organic acids, and<br />
triglycerides. The full color display and easy keypad entry of<br />
autozero, purge, and thermostatted flow cell temperature,<br />
assure reliable and accurate results every time.<br />
Detector Lamps 200/200a<br />
Components Part No. Each (€)<br />
Series 200 RI Tungsten Source 02712273 332<br />
Manuals/Maintenance Items/Accessories<br />
Components Part No. Each (€)<br />
Series 200 RI Detector Operator’s Manual 09938906 79<br />
Series 200a RI Detector Operator’s Manual 09936751 79<br />
LC-240 FL Detector<br />
Detector Lamps<br />
Components Part No. Each (€)<br />
LC-240 Xenon Source Lamp L2251157 555<br />
Festoon Lamp 04969486 9<br />
Manuals/Maintenance Items/Accessories<br />
Components Part No. Each (€)<br />
LC-240 R928 Photomultiplier 09972337 706<br />
Detectors Liquid Chromatography<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
315
Detectors<br />
UV/Visible Detector<br />
Series 200/785A UV/VIS<br />
Detector Source Lamps<br />
Description Part No. Each (€)<br />
Deuterium Lamp N2920149 510<br />
Tungsten Lamp N2920146 465<br />
Series 200 UV/VIS Detector<br />
Liquid Chromatography Detectors<br />
Series 200 UV/VIS Detector<br />
Outstanding sensitivity.<br />
The proven dual-beam optical design yields high<br />
sensitivity even for difficult ultra-trace analysis,<br />
detecting picogram quantities of many compounds.<br />
Couple that with your choice of either a Deuterium<br />
or Tungsten source for outstanding ultraviolet and<br />
true visible performance anywhere in the detector’s<br />
190-700 nm wavelength range. Lamp changes are<br />
quick and easy due to a unique, self-aligning lamp<br />
mount. Choose from several easily interchangeable<br />
flowcell formats to match your specific analytical<br />
needs – including a flowcell for microbore applications.<br />
Flexibility and ease-of-use are ensured through an<br />
optimized user interface – including an easy-to-read,<br />
multi-line display, tactile keyboard, and context-sensitive<br />
function keys. Full wavelength programmability, batterybacked<br />
method storage, and linking of methods allow for<br />
automated analysis, if required, and method development<br />
activities – all without computer control! A full suite of<br />
user accessible diagnostics allow for quick troubleshooting<br />
in the unlikely event of a problem – while an integrated<br />
leak-detector sounds an audible alert and halts your<br />
analysis if a solvent leak occurs.<br />
When single-point method control of your HPLC system<br />
is required, the Series 200 UV/Vis is fully controllable via<br />
PerkinElmer’s TotalChrom Chromatography Data Systems.<br />
The Series 200 UV/Vis features full digital output of<br />
chromatographic data, so an intermediary analog-to-digital<br />
interface is not required. This simplifies system installation<br />
and operation and reduces bench-space requirements as well.<br />
Deuterium Lamp Part No. N2920149<br />
Series 200/785A UV/VIS<br />
Flowcells/Flowcell<br />
Description Part No. Each (€)<br />
Flowcell Standard N2920117 2134<br />
Analytical (8 mm x 12 μL), for 785A only<br />
Analytical (19 mm x 15 μL), for UV 200 N2920124 546<br />
Flowcell Bulkhead Union 25000323 151<br />
Flowcell Assembly Microbore (6 mm x 2.4 μL) 29000544 2283<br />
Flowcell Assembly Prep (3 mm x 1.7 μL) 29000545 1224<br />
Heat Exchange Assembly, 785A 26000050 1180<br />
Heat Exchange Flowcell Assembly, N2920125 1357<br />
(10 mm x 15 μL), UV 200<br />
Reference Aperture Dry Cell 29000078 37<br />
Windows Flowcell Suprasil (pair) 72000008 146<br />
Series 200/785A UV/VIS<br />
Manuals/Maintenance Items<br />
Description Part No. Each (€)<br />
Backpressure Regulator 09907126 236<br />
Adjustable from 15-59 psi, stainless steel<br />
Cable 785A to TotalChrom 09410036 210<br />
Cable Assembly 60000186 70<br />
Detector Signal, for 785A only<br />
Cable Assembly 60000366 101<br />
Remote Autozero, for 785A only<br />
Series 200 Manual 09936504 106<br />
785A Manual, User’s Manual 09936189 198<br />
316
Ovens<br />
LC Column Ovens<br />
Series 200 Ovens<br />
In many HPLC analyses, variations in column temperature<br />
can cause significant changes in retention times, making<br />
qualitative analysis difficult and affecting the precision of<br />
quantitative measurements.<br />
Series 200 Peltier Column Oven<br />
PerkinElmer offers three versions of the Series 200<br />
Column Oven to meet your specific needs: heat-only,<br />
Peltier (heat and cool) and a Peltier unit with built-in<br />
column selection/switching valve.<br />
The PerkinElmer Series 200 family of column ovens controls<br />
the mobile phase and sample temperature before they enter<br />
the column via a built-in preheater. This eliminates thermal<br />
gradients across the column, resulting in better column<br />
performance and precise retention times. All heating<br />
and cooling (Peltier units only) is performed electrically,<br />
permitting sub-ambient temperatures as low as 5 °C without<br />
coolant or refrigerants.<br />
The Series 200 Oven/Selector permits automated switching<br />
of up to six HPLC columns via PerkinElmer’s TotalChrom<br />
data handling software. This feature is extremely beneficial<br />
for method development applications and in the<br />
multi-user/multi-method labs.<br />
Key Features:<br />
All electronic design permits wide operating range and leak<br />
alarm – Peltier units do not require refrigerants and coolants<br />
Peltier units use remote-control software permitting full<br />
oven and selector valve control in real-time or within<br />
a TotalChrom method sequence<br />
Integrated solvent pre-heater/chiller minimizes<br />
temperature gradients<br />
Large and easily accessible column compartment holds<br />
even 30 cm column formats<br />
Fully stackable design integrates into complete<br />
Series 200 system<br />
Heat Only Oven<br />
Precise temperature control as low as 5 °C above ambient<br />
to 100 °C; accuracy of +/- 1 °C and stability of +/- 0.05 °C<br />
with mobile phase preheating. LED display of set point<br />
and actual temperature. Stackable with other Series 200 LC<br />
modules. Removable front panel<br />
to access column compartment that Part No. Each (€)<br />
accepts up to 30 cm columns.<br />
N2601581 2220<br />
Peltier LC Column Compartment (120 -240 V)<br />
Precise temperature control as low as 7 °C to 90 °C;<br />
accuracy of +/- 1 °C and stability of +/- 0.2 °C with mobile<br />
phase preheating. LED display of set point and actual<br />
temperature. Audible leak alarm. Stackable with other Series<br />
200 LC modules. Removable front panel<br />
to access column compartment that<br />
accepts up to 30 cm columns.<br />
Part No.<br />
N2601580<br />
Each (€)<br />
3089<br />
Peltier Column Compartment and<br />
Selector Valve (120 -240 V)<br />
Precise temperature control from 5 °C to 90 °C; accuracy of<br />
+/- 1 °C and stability of +/- 0.2 °C with mobile phase<br />
preheating. LED display of set point and actual temperature.<br />
Audible leak alarm. Stackable with other Series 200 LC<br />
modules. Removable front panel to access column<br />
compartment that accepts up to 30 cm columns – or<br />
additional smaller column formats. Temperature and<br />
selection valve controlled via software running under<br />
TotalChrom 6.2 or greater. Includes Series 200 Accessory<br />
Control S/W (N2601585). Requires but does not include:<br />
Lantronix terminal (S2000062) or<br />
edge port USB to RS232 (09402020). Part No. Each (€)<br />
Series 200 Accessory Control Software<br />
Software to control heat<br />
only (N2601581) and Peltier<br />
Oven (N2601580).<br />
N2601579 4634<br />
Part No.<br />
Each (€)<br />
N2601585 309<br />
Ovens Liquid Chromatography<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
317
Pumps<br />
Degassing Kits<br />
Degassing Kits - Helium<br />
Helium degassing solvent packages are available in a<br />
choice of three solvent configurations. Each kit contains a<br />
manifold, bottles, and all required tubing and fittings. The<br />
helium manifold has been designed to prevent accidental<br />
over-pressurization and to eliminate the possibility of<br />
solvent migrating back into the helium supply lines. The<br />
glass bottles supplied with the kits are specially coated to<br />
ensure safety and prevent solvent leakage if accidentally<br />
dropped or otherwise broken.<br />
Description Part No. Each (€)<br />
Liquid Chromatography Pumps<br />
The 200 Series Vacuum degasser is a low volume, high<br />
efficiency, on-line module for removal of dissolved gases from<br />
HPLC solvents. The vacuum degasser is available in 3 and 5<br />
channel models to support isocratic, binary and quaternary<br />
pumps as well as degassing of autosampler flush solvent.<br />
Description Part No. Each (€)<br />
3-Channel Vacuum Degassing Package N2600571 1706<br />
Includes: a vacuum degasser, one 1 L bottle<br />
with cap, one 2 L bottle with cap, and an<br />
organizer and tray accessory<br />
5-Channel Vacuum Degassing Package N2600570 3174<br />
Includes: a vacuum degasser, two 1 L bottles<br />
with caps, two 2 L bottles with caps, solvent<br />
tray, and organizer<br />
Replacement Vacuum Degasser Bottles<br />
Description Part No. Each (€)<br />
1 L Glass Bottle N2600497 70<br />
2 L Glass Bottle N2600498 172<br />
Binary Solvent Package N2600505 1100<br />
Includes: one 1 L glass bottle kit and one 2 L<br />
glass bottle kit, with cap assemblies, one helium<br />
manifold, and a solvent organizer accessory<br />
Isocratic Solvent Package N2600491 721<br />
Includes: one 2 L glass bottle kit, with cap<br />
assembly, and a helium manifold<br />
Quaternary Solvent Package N2600506 1643<br />
Includes: two 1 L glass bottle kits and two 2 L<br />
glass bottle kits, with cap assemblies, one helium<br />
manifold, and a solvent organizer accessory<br />
200 Series Vacuum Degasser Kit Part No. N2600571<br />
Degassing System Spares - Helium<br />
200 Series On-line<br />
Vacuum Degasser Kits<br />
Description Size Part No. Each (€)<br />
1 L Glass Bottle N2600497 70<br />
1 L Glass Bottle Kit N2600456 351<br />
Includes: cap assembly, sparger (10 μm), solvent<br />
filter (10 μm), connecting fittings, and instructions<br />
2 L Glass Bottle N2600498 172<br />
2 L Glass Bottle Kit N2600457 414<br />
5 L Glass Bottle N2600499 268<br />
5 L Glass Bottle Kit N2600458 536<br />
Autosampler Flush Bottle Kit N2600459 395<br />
Bottle Cap Assembly N2600495 274<br />
For 1 L and 2 L glass bottles. Includes: sparger<br />
(10 μm), solvent filter (10 μm), connecting fittings<br />
Bottle Cap Assembly N2600496 312<br />
For 5 L glass bottle<br />
Helium Manifold Kit N2600284 459<br />
5 psi regulator<br />
Kel-F Ferrule 1/8 in. 09903771 4<br />
Tefzel Nut 1/8 in. N2601189 11<br />
Supply Connectors - Helium<br />
Each solvent reservoir system requires high-purity helium,<br />
either to pressurize or to degas the solvents. The helium<br />
pressure regulator with shut-off valve can deliver from 5 to<br />
180 psi of pressure from an external tank. We offer all the<br />
fittings needed to connect a helium source to your solvent<br />
reservoir system. Refer to your operator’s manual for<br />
step-by-step installation instructions.<br />
Description Part No. Each (€)<br />
Female Connector 09903906 23<br />
Reduces 1/4 to 1/8 in.<br />
Regulator 00230090 381<br />
5 to 180 psi with outlet shut-off valve<br />
Teflon Tubing 02506483 3<br />
Helium and Solvent Supply, per 1 ft. length<br />
1/8 in. o.d. x .06 in. i.d.<br />
318
Pumps<br />
Piston and Piston Accessories<br />
Check Valves<br />
Check valves, which include a sealing washer, are easy to install using the optional Torque Wrench kit. For all PerkinElmer<br />
pumps an intermediate check valve is required. The input check valve, which is identical, should be ordered.<br />
Standard Micropump Biocompatible<br />
Stainless Steel Stainless Steel Titanium<br />
Description Part No. Each (€) Part No. Each (€) Part No. Each (€)<br />
Inlet/Intermediate Check Valve 02540177 549 02540177 549 N2600226 759<br />
Outlet Check Valve 02540197 549 02540197 549 N2600192 695<br />
Check Valves<br />
Pistons<br />
Series 200 and Model 250/410 Pump Pistons<br />
High and low pressure pistons are made of sapphire for the highest quality hardness and surface.<br />
Standard Micropump Biocompatible<br />
Stainless Steel Stainless Steel Titanium<br />
Description Part No. Each (€) Part No. Each (€) Part No. Each (€)<br />
High Pressure Piston N2600124 344 N2910511 555 N2600124 344<br />
Low Pressure Piston N2600104 255 N2910512 899 N2600104 255<br />
Piston Seals<br />
Series 200 and Model 250/410 Piston Seals<br />
Pistons and Seals<br />
All PerkinElmer pumps contain a high and low pressure piston seal. In addition to the standard high pressure seal, we provide<br />
extended performance seals for more specialized requirements. The chemically resistant seal is composed of a graphite Teflon<br />
material. This seal is inert to an extended range of solvents, such as buffers. It cannot be used with high flows or pressures in<br />
excess of 3000 psi. Whenever replacing the low pressure seal, the Low Pressure Seal Back-Up Ring should also be replaced.<br />
Standard Micropump Biocompatible<br />
Stainless Steel Stainless Steel Titanium<br />
Description Part No. Each (€) Part No. Each (€) Part No. Each (€)<br />
High Pressure Piston Seal Backup O-Ring 09902128 1 09902128 1 09902128 1<br />
High Pressure Piston Seal Backup Ring 02542076 19 02542076 19<br />
High Pressure Piston Seal with Backup Ring 09923367 60<br />
High Pressure Piston Seal – Chemically Resistant (New) 09907345 66<br />
Low Pressure Piston Seal 09907339 60 09923366 40 09907339 60<br />
Low Pressure Piston Seal Backup Guide Bushing 02542313 27 N2601174 98<br />
Standard High Pressure Piston Seal (Gold) 09907324 55 09907338 80<br />
Pumps Liquid Chromatography<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
319
Pumps<br />
Piston and Piston Accessories<br />
Seals, Pistons, and Check Valves<br />
Standard Micropump Biocompatible<br />
Stainless Steel Stainless Steel* Titanium*<br />
Component Part No. Each (€) Part No. Each (€) Part No. Each (€)<br />
Liquid Chromatography Pumps<br />
1<br />
2<br />
3<br />
4<br />
5<br />
6<br />
7<br />
8<br />
9<br />
Standard High Pressure Piston Seal (Gold) 09907324 55 09907338 80<br />
High Pressure Piston Seal – Chemically Resistant (New) 09907345 66<br />
High Pressure Piston Seal Backup Ring 02542076 19 02542076 19<br />
High Pressure Piston Seal with Backup Ring 09923367 60<br />
High Pressure Piston Seal Backup O-Ring 09902128 1 09902128 1 09902018 1<br />
Low Pressure Piston Seal 09907339 60 09923366 40 09907339 60<br />
Low Pressure Piston Seal Backup Guide Bushing 02542313 27 N2601174 98<br />
High Pressure Piston N2600124 344 N2910511 555 N2600124 344<br />
Low Pressure Piston N2600104 255 N2910512 899 N2600104 255<br />
Inlet/Intermediate Check Valve 02540177 549 02540177 549 N2600226 759<br />
Outlet Check Valve 02540197 549 02540197 549 N2600192 695<br />
* Refer to the User’s Manual for a complete illustrated parts list.<br />
6<br />
9<br />
1<br />
2<br />
3<br />
4<br />
Exploded view of standard stainless steel pump head.<br />
5<br />
7<br />
8<br />
320
Pumps<br />
Pump Accessories<br />
Bio Conversion Kit<br />
Bio Conversion Kit<br />
For the Series 200 Pump and Series 200 Autosampler. Kit<br />
contains all of the parts necessary to<br />
convert the pump and the autosampler<br />
for Bio applications.<br />
Part No.<br />
N2910035<br />
Each (€)<br />
3793<br />
Maintenance Kits and Tools<br />
Description Part No. Each (€)<br />
Biocompatible Piston Seal Replacement Kit N2910385 592<br />
Includes: four seals, backup rings, and O-Rings<br />
Check Valve Torque Wrench 02540871 35<br />
Diaphragm for Pulse Compensator N2601316 140<br />
High Pressure Piston Seal Replacement Kit N2910383 302<br />
Includes: four seals, backup rings, and O-Rings<br />
Insertion Tool N2601503 83<br />
Micropump Piston Seal Replacement Kit N2910384 417<br />
Pulse Compensator Repair Kit N2600313 78<br />
Includes: diaphragm, elastomer plug, and seal<br />
Seal Removal Tool N2601295 7<br />
Series 200 Bio LC Pump Maintenance Kit N2910346 2321<br />
Includes: fuses, seals, O-Rings, and seal tools<br />
Series 200 Pump Maintenance Kit N2910345 931<br />
Includes: fuses, seals, O-Rings, and seal tools<br />
Manuals and Accessories<br />
Description Part No. Each (€)<br />
Model 250 Operator’s Manual 09937169 107<br />
Pump Backpressure Regulator (to generate 02540272 548<br />
backpressure for applications less than 250 psi)<br />
Pump Priming Syringe (30 mL, plastic) 09904849 2<br />
Series 200 Operator’s Manual 09938910 92<br />
Series 200 Pump Injector Bracket N2910349 53<br />
Mixers<br />
Series 200 Dynamic Mixer<br />
Series 200 Dynamic Mixer Accessory (100-240 V) – Used<br />
to facilitate complete mobile phase blending, resulting in<br />
improved retention performance. The mixer will most<br />
typically be used as part of a Series 200 Micro pump<br />
package – where high-pressure blending of 2 pump<br />
outputs is required. Three different volume mixing heads<br />
(75, 200, and 400 μL) are available.<br />
Kit includes: Mixer Accessory, stainless<br />
steel “tee” fitting (N2911127), U.S. style<br />
AC line cord and 0.1 A Type T fuse.<br />
Mixing Heads<br />
Part No.<br />
Each (€)<br />
N2910520 416<br />
Size Part No. Each (€)<br />
75 μL N2910521 349<br />
200 μL N2910522 332<br />
400 μL N2910523 332<br />
Series 200 Dynamic Mixer Mounting Bracket<br />
Allows the mixer to be mounted to<br />
the side of a Series 200 Autosampler<br />
for stacked configurations.<br />
Static Mixers<br />
Static Mixers with high efficient<br />
vortex sheer mixing<br />
Improve gradient accuracy<br />
Increase sensitivity<br />
Reduce baseline noise<br />
In-line binary format<br />
Ideal for microbore HPLC LC/MS<br />
Description Size Part No. Each (€)<br />
Binary T Mixer, Stainless Steel 10 μL N2911170 659<br />
Binary T Mixer, Stainless Steel 150 μL N2911171 659<br />
In-line Mixer Assembly 150 μL N2911173 617<br />
In-line Mixer Assembly 500 μL N2911172 730<br />
Static Mixers Replacement Cartridges<br />
Part No.<br />
Description Size Part No. Each (€)<br />
For 10 μL Binary T Mixer 10 μL N2911174 309<br />
For 10 μL Binary T Mixer 25 μL N2911175 309<br />
For 150 μL Binary T Mixer 50 μL N2911176 309<br />
For 150 μL Binary T Mixer 150 μL N2911177 309<br />
For 150 μL Binary T Mixer 250 μL N2911178 309<br />
Pulse Compensators<br />
The pulse compensator combines high-efficiency pulse<br />
smoothing with a low void volume. A Teflon diaphragm<br />
separates a reservoir filled by an RTV elastomer plug.<br />
Normal use will necessitate the eventual replacement<br />
of the diaphragm.<br />
Each (€)<br />
N2915102 58<br />
Description Part No. Each (€)<br />
Diaphragm for Pulse Compensator N2601316 140<br />
Pulse Compensator Repair Kit N2601313 54<br />
Includes: diaphragm, elastomer plug, and seal<br />
Series 200 Pump Solvent Upgrade Kits<br />
The unique design of the PerkinElmer Series 200 Pump<br />
allows it to easily be upgraded for additional solvent<br />
capability right in your laboratory as your needs change.<br />
Installation of the kit by a PerkinElmer Service and Support<br />
is recommended, but not included. Contact your local<br />
PerkinElmer representative for more information.<br />
Description Part No. Each (€)<br />
Series 200 Binary to Quaternary Upgrade Kit N2910344 4744<br />
Series 200 Isocratic to Binary Upgrade Kit N2910342 4451<br />
Series 200 Isocratic to Quaternary Upgrade Kit N2910343 8400<br />
Pumps Liquid Chromatography<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
321
Pumps<br />
Solvent Filters and Spargers<br />
Solvent Spargers<br />
Solvent Reservoir Sparger<br />
Description Size μm Part No. Each (€)<br />
Stainless Steel 10 09903610 68<br />
Titanium 10 N2600070 65<br />
Stainless Steel 40 09903615 68<br />
Titanium 40 N2600089 75<br />
Solvent Filters<br />
Solvent Sparger<br />
Liquid Chromatography Pumps<br />
Solvent Filters<br />
In-line Solvent Filter System<br />
For stainless steel pumps.<br />
In-line Solvent Filter Replacement Kit<br />
For all stainless steel pumps.<br />
Includes two 0.5 μm filter<br />
elements and four seals.<br />
In-line Solvent Filter System, Titanium<br />
For Biocompatible pumps.<br />
Replacement 2 μm Titanium Filter Element<br />
For in-line solvent filter for Biocompatible pumps. Requires,<br />
but does not include, Replacement Seal<br />
for In-line Solvent Filter (N2601262). Part No. Each (€)<br />
Replacement Seal for In-line Solvent Filter<br />
For Biocompatible pumps. Use with<br />
Replacement 2 μm Titanium Filter<br />
Element (N2601477).<br />
Part No.<br />
Part No.<br />
Each (€)<br />
02540311 68<br />
Part No.<br />
Each (€)<br />
09903606 126<br />
Each (€)<br />
N2600259 631<br />
N2601477 140<br />
Part No.<br />
Each (€)<br />
N2601262 28<br />
322
Supplies and Accessories<br />
Fittings<br />
Fittings<br />
Stainless steel nuts are available in both Parker-Hannifin<br />
and Rheodyne formats. The nuts are used to connect 1/16<br />
in. o.d. stainless steel tubing and feature a 10-32 thread size.<br />
PerkinElmer also offers select SSI fittings for 1/16 in. o.d.<br />
tubing in 1/4-28 thread size.<br />
For biocompatible applications, both plastic and Isopure<br />
titanium fittings are available. PerkinElmer has created a<br />
Biocompatible Column Fittings Kit which contains fittings<br />
of various inert materials, such as PEEK and Tefzel ® .<br />
Description Qty. Part No. Each (€)<br />
Fingertight One-Piece Nut and Ferrule 1 09920513 17<br />
Parker-Hannifin Ferrule, 1/16 in. 1 00873032 15<br />
Parker-Hannifin Nut, 1/16 in. 1 09903980 19<br />
Parker-Hannifin Nut and Ferrule Kit, 1/16 in. 1 00890945 147<br />
Parker-Hannifin Zero-dead-volume Union, 1 09903289 92<br />
with nuts and ferrules<br />
Rheodyne Ferrule, 1/16 in. 1 09904947 10<br />
Rheodyne Nut, 1/16 in.: long body 1 09904974 14<br />
Rheodyne Nut, 1/16 in.: short body 1 09904956 11<br />
Rheodyne Nut and Ferrule Kit, 1/16 in. 1 02540274 92<br />
6 ferrules, 3 short nuts, 3 long nuts<br />
RheoFlex PEEK Nut and Ferrule Set (pkg. 10) 1 N9302676 62<br />
SSI Nut and Ferrule Kit,1/16 in. 1 02540273 68<br />
5 nuts and 10 ferrules<br />
Swagelok Zero-dead-volume Union 1 09903807 106<br />
Titanium Ferrule, 1/16 in. 1 N2601346 17<br />
Titanium Long Nut, 1/16 in. 1 N0911038 73<br />
Titanium Short Nut, 1/16 in. 1 N0911028 31<br />
Tube Nut 410 Bio Pump 1 N2601149 56<br />
Valco Ferrule, 1/16 in. 1 09903891 4<br />
Valco Nut, 1/16 in. 1 09903890 4<br />
Fittings Kits<br />
Biocompatible Column Fittings for LC<br />
Recommended for users of a<br />
PerkinElmer Biocompatible LC system.<br />
Contains nuts, ferrules, and unions.<br />
Fittings Kit for LC<br />
All-in-one fittings kit. The kit contains Rheodyne and SSI<br />
nuts and ferrules as well as Fingertight II nuts and ferrules<br />
for toolless installation. Zero-dead-volume and low-deadvolume<br />
unions are also included. In addition, you receive<br />
varying lengths of stainless steel tubing<br />
in 0.007 and 0.010 in. i.d.s, as well Part No. Each (€)<br />
as 0.030 in. i.d. Tefzel tubing.<br />
N9301002 727<br />
Operation Kit<br />
Recommended for purchasers of their<br />
first LC. Includes tubing, union, fittings,<br />
syringe, basic LC book, and test mix.<br />
PEEK One-Piece<br />
Fingertight TM Fittings<br />
PEEK Union<br />
Part No.<br />
This PEEK Fingertight is the<br />
toughest in regard to chemical<br />
resistance and pressure. This<br />
high-performance fingertight is<br />
recommended for the most<br />
demanding applications and will<br />
resist pressures up to 6000 psi<br />
(400 bar). The diameter of the<br />
head of the nuts has been<br />
increased by 50% to give you<br />
power enough to tighten without<br />
tools. The nut and ferrule are<br />
made from a single piece of<br />
PEEK. (pkg. 10)<br />
Part No.<br />
Each (€)<br />
N9301001 631<br />
Part No.<br />
Each (€)<br />
00890873 721<br />
Each (€)<br />
ED020005 71<br />
The PEEK union allows you to connect two pieces of 1/16 in.<br />
tubing quickly and reliably. This union features a .012 in.<br />
thru-hole of minimum length for the lowest possible dead<br />
volume. Because this is a PEEK union, it is absolutely inert<br />
and biocompatible. The PEEK<br />
union comes without nuts. (pkg. 5)<br />
Part No. Each (€)<br />
ED020008 51<br />
Supplies and Accessories Liquid Chromatography<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
323
Supplies and Accessories<br />
Rheodyne Injection Valves<br />
Rheodyne 7725 Injection Valve<br />
Rheodyne 7010 Injection Valve<br />
Liquid Chromatography Supplies and Accessories<br />
The Model 7725 and 7725i are Rheodyne’s most advanced<br />
sample injectors for analytical HPLC. They can inject from<br />
1 μL to 5 mL with high accuracy and precision. These<br />
versatile injectors can use either of two methods for loading<br />
the sample loop. The partial-filling method uses the syringe<br />
to measure the sample volume. It lets you vary volume<br />
easily without having to change the loop, and it does not<br />
waste any sample. Any amount up to half the loop volume<br />
can be loaded. The amount injected into the column is the<br />
exact volume dispensed from the syringe. The completefilling<br />
method uses the loop to measure the volume. It lets<br />
you load the loop without having to read syringe calibrations<br />
carefully. Excess sample is required to completely flush<br />
mobile phase from the loop. The amount injected is the<br />
volume of the loop.<br />
Flow switching occurs at a flat interface between a<br />
polymeric rotor seal and a ceramic stator face. This<br />
combination provides long seal life. In a clean system,<br />
the 7725 typically can make more than 30,000 injections<br />
before requiring replacement of the rotor seal.<br />
The Models 7725 and 7725i are essentially identical, but<br />
the latter has a built-in position sensing switch, which can<br />
provide the chromatograph with a reproducible start signal.<br />
These models are new versions of the popular Model 7125.<br />
New features include:<br />
Flow is not interrupted during switching, a benefit when<br />
using flow-sensitive detectors, fragile columns, or pumps<br />
that are disturbed by pressure transients. A patented<br />
make-before-break or MBB TM passage makes new<br />
connections before old ones break<br />
Wide port angles provide improved access to fittings<br />
A front-end pressure screw makes it easy to adjust<br />
and maintain<br />
A 2 μL internal sample loop is available. The new models<br />
use the same rotor seals as the 7125, but sample loops and<br />
some other parts are not interchangeable. These injectors are<br />
set for 5000 psi (345 bar, 34 MPa) and are adjustable to 7000<br />
psi (483 bar, 48 MPa). Maximum temperature is 60 °C. A 20 μL<br />
loop is attached when a complete valve is purchased<br />
7725 Injection Valve<br />
For use in the Series 200 Autosampler.<br />
7725i Injection Valve with Internal Switch<br />
For stand-alone use.<br />
Part No.<br />
Part No.<br />
Each (€)<br />
N9306019 1033<br />
Each (€)<br />
N9306017 1090<br />
7010 Injection Valve<br />
The Model 7010 is a single-mode injector for the completefilling<br />
method of loading the sample loop. You can achieve<br />
high precision without the need to read syringe calibrations<br />
carefully. You should load an excess of sample – at least<br />
two loop volumes – to flush mobile phase from the loop.<br />
The 7010 can also be used as a column-switching valve. The<br />
injector ships with a 20 μL loop attached. Pressure is set for<br />
5000 psi and is adjustable to 7000 psi.<br />
Rotor seal is a Vespel polymer, which Part No. Each (€)<br />
has an operating pH range of 0-10. 02540142 785<br />
Rheodyne 8125 Low-Dispersion<br />
Stainless Steel Injection Valve<br />
8125 Injection Valve<br />
Ideal for use in an LC/MS system, the Model 8125 is<br />
designed for 1 mm and 2 mm microbore columns, and<br />
can also be used with conventional analytical columns<br />
(3 to 5 mm). It can inject sample volumes from 0.5 to 50 μL<br />
with zero sample waste, using the partial-filling method.<br />
Small flow passages produce low dispersion, maintaining<br />
the high mass sensitivity inherent in micro columns.<br />
The 8125 Low-dispersion injector can quickly and easily be<br />
added to the PerkinElmer Series 200<br />
Autosampler, thus making it an ideal<br />
choice as a LC/MS sampling accessory.<br />
Part No.<br />
N9306021<br />
Each (€)<br />
1938<br />
Rheodyne 9725 PEEK Injection Valve<br />
The Model 9725 is highly inert and well-suited to the<br />
chromatography of biological molecules using all techniques,<br />
including those with aggressive mobile phases. It applies to<br />
both HPLC and soft gel chromatography, and is also suitable<br />
for ion chromatography, since metal does not contact the<br />
mobile phase. This injector is identical to the Model 7725<br />
stainless steel injector, but the materials are different: the<br />
loop, nuts, ferrules, stator, and vent lines are made of PEEK,<br />
polyetheretherketone; the rotor seal polymer is Tefzel. PEEK<br />
has an outstanding combination of strength and inertness.<br />
The operating pH range is 0 to 14. The injector is set for its<br />
maximum pressure capability, 5000 psi (345 bar, 34 MPa).<br />
However, useable pressure may be lower, since the burst<br />
pressure of the PEEK sample loop usually limits it.<br />
Maximum temperature is 50 °C. A 20 μL loop is attached.<br />
The Rheodyne 9725 can quickly and easily be added to<br />
the PerkinElmer Series 200 Autosampler, making it an<br />
ideal sampling accessory for biochemistries. The Series<br />
200 Autosampler also supports Peltier-cooled sample<br />
trays for temperature labile samples (see page 270).<br />
9725 Injection Valve<br />
For use in the Series 200 Autosampler.<br />
Part No.<br />
Each (€)<br />
N9306020 1530<br />
324
Supplies and Accessories<br />
Rheodyne Injection Valves<br />
Rheodyne Valves Spare Parts<br />
1<br />
2<br />
3<br />
4<br />
5<br />
6<br />
7<br />
8<br />
9<br />
10<br />
11<br />
12<br />
13<br />
14<br />
15<br />
16<br />
17<br />
18<br />
Model 9725 Model 8125 Model 7010 Model 7125 Model 7725<br />
Part Part No. Each (€) Part No. Each (€) Part No. Each (€) Part No. Each (€) Part No. Each (€)<br />
Handle Screw<br />
Handle<br />
Knob Assembly<br />
Set Screws<br />
Needle Guide<br />
S200 Autosampler N2931054 51 N2931054 51 N2931054 51<br />
Manual Valve 09904800 28 09904800 28 09904800 28 09904800 28<br />
ISS-100 02541946 47<br />
Body<br />
Thrust Bearing<br />
Rotor Pin<br />
Seal Pins<br />
Needle Port Tube 09904805 40 09904805 40 09904805 40 09904805 40<br />
Bearing Ring 09904963 47 09904963 47<br />
Isolation Seal 09904962 85 09904962 85<br />
Rotor Seal<br />
Vespel 09904802 98 10070900 125 09904955 94 09904802 98 09904802 98<br />
Tefzel N9302677 103 N9302677 103 N9302677 103<br />
PEEK N9306044 105 N9306044 105 N9306044 105<br />
Stator Ring<br />
Stator Face Assembly 09904801 347<br />
PEEK and Ceramic N9306047 179 N9306047 179<br />
Set Screws<br />
Stator 10071000 1849 09904953 293<br />
PEEK N9306046 338<br />
Stainless Steel 09904953 293 N9306045 402<br />
Titanium N0911041 740<br />
Stator Screws<br />
1 2<br />
7<br />
10<br />
3<br />
4<br />
5<br />
6<br />
8<br />
9<br />
11<br />
12<br />
13<br />
14<br />
15<br />
16<br />
17<br />
18<br />
Rheodyne Injection Valve<br />
Supplies and Accessories Liquid Chromatography<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
325
Supplies and Accessories<br />
Rheodyne Sample Loops<br />
Internal Loop for<br />
Models 7725/9725<br />
PEEK Sample Loops<br />
for Rheodyne Valves<br />
Liquid Chromatography Supplies and Accessories<br />
Description Part No. Each (€)<br />
2 μL (PEEK and Ceramic) N9306022 230<br />
Sample Loops<br />
Stainless Steel Sample Loops for Rheodyne Valves and Injectors<br />
PEEK Sample Loops avoid many of the problems associated<br />
with stainless steel sample loops. Metal loops will often<br />
absorb sample components resulting in inaccurate quantitative<br />
results. In addition, metal loops may be corroded by<br />
high-salt buffers and chloride salts. Sample Loops are<br />
made from PEEK tubing and fittings. PEEK (Poly-Ether-<br />
Ether-Ketone) is a mechanically strong, chemically inert<br />
polymer ideal for HPLC applications where metal surfaces<br />
may interact with mobile phase or sample components.<br />
Each Sample Loop is supplied with two PEEK hex-head<br />
nuts and ferrules. These fittings grip the tubing in two<br />
locations for a more reliable connection.<br />
Model 9725<br />
Description Part No. Each (€)<br />
5 μL PEEK Sample Loop N9306033 125<br />
10 μL PEEK Sample Loop N9306034 125<br />
20 μL PEEK Sample Loop N9306035 125<br />
50 μL PEEK Sample Loop N9306036 125<br />
100 μL PEEK Sample Loop N9306037 125<br />
200 μL PEEK Sample Loop N9306038 140<br />
500 μL PEEK Sample Loop N9306039 185<br />
1 mL PEEK Sample Loop N9306040 140<br />
2 mL PEEK Sample Loop N9306041 210<br />
5 mL PEEK Sample Loop N9306042 351<br />
Model 7125/7010 Model 7725 Model 8125<br />
Description Part No. Each (€) Part No. Each (€) Part No. Each (€)<br />
5 μL Stainless Steel Sample Loop 09904827 61 N9306023 83 20143300 125<br />
10 μL Stainless Steel Sample Loop 09904938 59 N9306024 83<br />
20 μL Stainless Steel Sample Loop 09904939 59 N9306025 83 10082600 78<br />
50 μL Stainless Steel Sample Loop 09904940 59 N9306026 83<br />
100 μL Stainless Steel Sample Loop 09904942 65 N9306027 83 41000013 78<br />
200 μL Stainless Steel Sample Loop 09904818 61 N9306028 83 09904818 61<br />
500 μL Stainless Steel Sample Loop 09904819 68 N9306029 83<br />
1 mL Stainless Steel Sample Loop 09904820 75 N9306030 83<br />
2 mL Stainless Steel Sample Loop N9306031 172<br />
5 mL Stainless Steel Sample Loop N9306032 210<br />
Note: Loops are compatible with both manual valves and Series 200 Autosampler valves.<br />
326
Supplies and Accessories<br />
Sample Introduction<br />
Microsyringes (For Manual Injection)<br />
Syringes are used for accurate and precise liquid delivery.<br />
Each syringe is hand-fitted to assure maximum accuracy.<br />
Our syringes are composed of glass barrels and precision<br />
stainless steel needles. The needle features a blunt tip,<br />
required for use with a Rheodyne injector.<br />
Description Part No. Each (€)<br />
10 μL Syringe 09904937 59<br />
25 μL Syringe 09904823 52<br />
50 μL Syringe 09904941 60<br />
100 μL Syringe 09904822 62<br />
Rheodyne 22-gauge Blunt Needle with Luer Hub 09904943 34<br />
PEEK Tubing<br />
PEEK tubing has the strength required to withstand continuous<br />
use at HPLC pressure without swelling or bursting. The<br />
dense polymer structure of PEEK tubing eliminates the<br />
permeability to organic solvents that causes other polymer<br />
tubing, such as Tefzel ® to “sweat.”<br />
Use PEEK tubing with virtually any organic or inorganic<br />
liquid. PEEK tubing is not affected by halide salts, high<br />
strength buffers or other aggressive mobile phases that<br />
degrade stainless steel.<br />
Description Size Part No. Each (€)<br />
1/16 in. o.d. x .007 in. i.d. 5 ft. N9302678 40<br />
1/16 in. o.d. x .010 in. i.d. 5 ft. N9302650 34<br />
Solvent and Sample Filtration<br />
All-Glass Filter Apparatus<br />
For solvent filtration.<br />
FP Vericel Hydrophilic Filters<br />
For aqueous mobile phase,<br />
47 mm, 0.45 μm. (pkg. 100)<br />
PTFE Hydrophobic Filters<br />
For nonaqueous mobile phase,<br />
47 mm, 0.45 μm. (pkg. 100)<br />
Sample Filter Assembly<br />
Acro LC-13 13 mm, 0.45 μm,<br />
for common reversed-phase<br />
solvents. (pkg. 100)<br />
Sample Filter Assembly<br />
Acrodisk CR-13 13 mm, 0.45 μm,<br />
for THF, DMSO, etc. (pkg. 100)<br />
Part No.<br />
Each (€)<br />
N9301063 867<br />
Part No.<br />
Each (€)<br />
N9301067 230<br />
Part No.<br />
Each (€)<br />
N9301068 593<br />
Part No.<br />
Each (€)<br />
02542783 370<br />
Part No.<br />
Each (€)<br />
02542782 351<br />
Tubing and Connectors<br />
Stainless Steel Tubing<br />
SS-316 Tubing<br />
Description Size Part No. Each (€)<br />
1/16 in. o.d. x .043 in. i.d. 6 ft. 00873035 77<br />
1/16 in. o.d. x .015 in. i.d. 6 ft. 00873036 66<br />
1/16 in. o.d. x .007 in. i.d. 3 ft. 02540838 140<br />
1/16 in. o.d. x .007 in. i.d. 20 cm 02711441 9<br />
1/16 in. o.d. x .007 in. i.d. 50 cm 00891480 37<br />
Tefzel Tubing<br />
Description Size Part No. Each (€)<br />
1/16 in. o.d. x .030 in. i.d. 10 ft. N9301029 64<br />
Tubing Accessories<br />
For cutting polymeric tubing.<br />
Clean-Cut TM Tubing<br />
The Clean-Cut is designed to cut Teflon ® , Tefzel, and<br />
polymers in general, and PEEK capillary tubing in particular.<br />
The compact design enables every chromatographer to carry<br />
it in his pocket. A unique safety locking mechanism secures<br />
the blade when not in use.<br />
Suitable for dimensions from<br />
Part No. Each (€)<br />
1/16 to 1/8 in. (pkg. 1)<br />
ED020015 18<br />
Replacement Blade<br />
(pkg. 10)<br />
Tubing Plier<br />
Part No.<br />
Each (€)<br />
ED020016 13<br />
For cutting 1/16 in. stainless steel capillaries. Annealed<br />
jaws with plastic handles.<br />
Avoids distortion of o.d.<br />
and closing the i.d. (pkg. 1)<br />
Part No.<br />
ED020017<br />
Each (€)<br />
33<br />
Supplies and Accessories Liquid Chromatography<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
327
TotalChrom CDS<br />
Software<br />
TotalChrom TM<br />
Chromatography Data Systems<br />
A proven solution with leading edge productivity.<br />
The TotalChrom Client/Server (TC C/S) Data System is the<br />
solution in multi-user environments. TC C/S systems can<br />
easily integrate all existing chromatographs into a single<br />
networked system supporting an unlimited number of<br />
users and an unlimited number of chromatographs.<br />
TotalChrom features TC Publisher, a powerful application<br />
that extends report capabilities beyond the standard<br />
templates by providing a sophisticated laboratory report<br />
generator using standardized tools. Unique features let<br />
you graphically format the exact report as needed without<br />
extensive training or special commands. It ensures that<br />
the stages of chromatographic analysis, report generation,<br />
and distribution are quick, easy, and complete.<br />
Report templates can perform calculations between different<br />
peaks in the same sample or even between samples, as well<br />
as automate statistical determination to replicate injections,<br />
with full control over the output format.<br />
Streamlining your laboratory workflow,<br />
the entire process from setting up an<br />
analytical method to the final approval<br />
of reports is a streamlined series of<br />
operations in TotalChrom<br />
PerkinElmer’s TotalChrom Chromatography Data System<br />
(CDS) is designed to provide laboratories with the total<br />
answer to chromatography data handling needs.<br />
Acquiring, processing, reporting, reviewing and approving<br />
data is a streamlined series of operations in PerkinElmer’s<br />
TotalChrom Chromatography Data System, software<br />
designed to fit your laboratory workflow and maximize<br />
productivity. With its scalable architecture, 21 CFR part<br />
11 compliance features and proven algorithms,<br />
TotalChrom offers a computing strategy to manage your<br />
chromatography data quickly and securely in both<br />
regulated and non-regulated environments.<br />
Quickly and Easily Navigate,<br />
Review and Approve Your Data<br />
In the “paper world” reports need to be reviewed and<br />
signed. The TotalChrom Review & Approve (R&A) feature<br />
is a Graphical Reviewing environment that allows intuitive<br />
navigation into data and reports, and provides for the<br />
implementation of a data approval cycle. With TC R&A,<br />
chromatograms, raw data results, and reports can be easily<br />
viewed and compared at a glance.<br />
Reviewing and approving reports can be done electronically,<br />
with multiple levels of authority and secure electronic<br />
signatures. High throughput applications have dramatically<br />
increased the amount of information produced every<br />
day in a laboratory. This feature streamlines tedious data<br />
review by using one single environment to navigate into<br />
data, just like we, every day, navigate into e-mail.<br />
When configured with a PerkinElmer Clarus 500 Gas<br />
Chromatograph or a PerkinElmer Series 200 Liquid<br />
Chromatograph, the TotalChrom Data System is the<br />
controller and data manager for the overall system.<br />
TotalChrom systems can also control selected instruments<br />
from other vendors and can acquire data from any<br />
chromatographic system through A/D interface.<br />
328 www.perkinelmer.com/<strong>supplies</strong>
Software<br />
Intelligent Interfaces for TotalChrom<br />
TotalChrom systems utilize PerkinElmer Intelligent<br />
Interfaces to connect each chromatography system to the<br />
data system PC. Each interface contains buffered RAM<br />
memory to maintain data collection in the event that the PC<br />
or PC network becomes inoperative during data acquisition.<br />
Data from instruments is never lost and chromatograph<br />
productivity is preserved.<br />
Analog chromatographs connect to TotalChrom through<br />
NCI (Network Chromatography Interface) Series Intelligent<br />
Interfaces. The model NCI 901 is a single-channel device,<br />
while the model NCI 902 is a dual-channel device. Both<br />
interface models are capable of taking analog detector data<br />
(unipolar or bipolar) at sampling rates from 0.1 to 100 Hz.<br />
dotLINK<br />
dotLINK–interfacing with ease<br />
dotLINK is a Windows CE-based interface that allows you<br />
to connect your Clarus 500 GC and Series 200 HPLC, plus<br />
Agilent 1100 and Agilent 6890 GCs directly to the network.<br />
Designed to face today’s workload challenges and provide<br />
Ethernet connectivity, dotLINK allows external buffering<br />
with a minimal need for validation. The dotLINK box has a<br />
small footprint providing valuable space for your laboratory.<br />
dotLINK supports the following GC and HPLC configurations:<br />
Maximum of 3 PKI Clarus 500 GCs<br />
Maximum of 1 PerkinElmer Series 200 HPLC System Stack<br />
Maximum of 2 Agilent 6890 GCs<br />
Maximum of 1 Agilent 1100 HPLC/UV System Stack<br />
NCI Intelligent Interfaces<br />
NCI Series Intelligent Interfaces are 24-bit, either single or<br />
dual-channel, buffered, A/D converters which have softwareselectable<br />
input voltage ranges of 10, 2, 1, and 0.1 V with<br />
6-decade dynamic range, programmable sampling rates<br />
from 0.1 to 100 points per second selectable in TotalChrom<br />
software, less than 1 microvolt noise (peak to peak), 0.1%<br />
linearity, three sense input lines, and one system READY<br />
relay for communication with Autosamplers. Includes a<br />
board containing seven programmable relays and a Rack/<br />
Vial Port (TTL voltage levels) for reading Autosampler vial<br />
BCD information. Memory is segmentable for multiple<br />
chromatograms. Software selectable symmetric bipolar or<br />
unipolar mode operation. All Interfaces carry a one-year<br />
return to Service Depot warranty.<br />
Model NCI 901 Intelligent Interface<br />
with RVP/Relay Board, 120 V<br />
Single channel A/D with 256 KB RAM memory<br />
and RVP/Relay board. Stores up to 120 K data points.<br />
Unipolar/bipolar operation modes. Requires, but<br />
does not include, one IEEE or RS232 interface cable.<br />
Includes 120 V power cord.<br />
Part No. Each (€)<br />
S9000070<br />
Model NCI 901 Intelligent Interface<br />
with RVP/Relay Board, 240 V<br />
Single channel A/D with 256 KB RAM memory<br />
and RVP/Relay board. Stores up to 120 K data points.<br />
Unipolar/bipolar operation modes. Requires, but<br />
does not include, one IEEE or RS232 interface cable.<br />
Includes 240 V power cord.<br />
Part No. Each (€)<br />
Model 902 Intelligent Interface<br />
with RVP/Relay Board, 120 V<br />
Model 902 Intelligent Interface<br />
with RVP/Relay Board, 240 V<br />
S9000075 2671<br />
Dual channel A/D with 256 KB RAM memory<br />
and RVP/Relay board. Stores up to 120 K data points.<br />
Unipolar/bipolar operation modes. Requires, but<br />
does not include, one IEEE or RS232 interface cable.<br />
Includes 120 V power cord.<br />
Part No. Each (€)<br />
S9000090<br />
Dual channel A/D with 256 KB RAM memory<br />
and RVP/Relay board. Stores up to 120 K data points.<br />
Unipolar/bipolar operation modes. Requires, but<br />
does not include, one IEEE or RS232 interface cable.<br />
Includes 240 V power cord.<br />
Part No. Each (€)<br />
S9000095 4010<br />
Software Liquid Chromatography<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
329
Software<br />
Interface Modules for TotalChrom<br />
Interface Personality Modules (IPM)<br />
Interface Validation Modules (IVM)<br />
Liquid Chromatography Software<br />
IPMs are instrument-specific software programs that<br />
interpret and translate instrument control and data<br />
acquisition parameters between TotalChrom and a specific<br />
digital instrument. IPMs are downloaded from the host PC<br />
(TotalChrom) by a configuration function to a specific<br />
(Serial or Ethernet) port on a dotLINK interface (internal<br />
or external). Downloaded IPMs are stored in nonvolatile<br />
memory in the dotLINK interface.<br />
IPM for Agilent 1100 HPLC<br />
Provides control for the Agilent series 1100 HPLC modules.<br />
Each dotLINK Interface or M610 can accommodate one<br />
HPLC instrument system. Requires, but does not include,<br />
serial communication cable for each Agilent 1100 module<br />
controlled by TotalChrom.<br />
Description Part No. Each (€)<br />
TotalChrom Client Server N5150267 494<br />
TotalChrom Workstation N5150167 494<br />
IPM for PerkinElmer LC Systems<br />
Provides complete control of PerkinElmer HPLC pumps,<br />
random access autosampler, diode array detectors (S200<br />
and LC-235C), and programmable UV/Vis detectors (S200<br />
and LC-785A)* with simultaneous digital data acquisition<br />
from two channels per detector. This IPM may be configured<br />
across one or more dotLINK or 600 Series LINK interface(s)<br />
on a single TotalChrom acquisition system. Each dotLINK<br />
interface can accommodate one HPLC instrument system.<br />
Requires, but does not include, one Turbo LC Plus<br />
Communications Kit for each LC module controlled by<br />
TotalChrom Workstation. Also compatible with TurboChrom<br />
Workstation v6 data systems.<br />
Description Part No. Each (€)<br />
TotalChrom Client Server N5150262 494<br />
TotalChrom Workstation N5150162 494<br />
* Series 200 UV/Vis detector requires TotalChrom<br />
or TurboChrom Workstation v6.1.2 or higher.<br />
Model 520 Interface Validation Module, 120 V<br />
The Model 520 IVM is a calibrated analog peak pattern<br />
generator for use in testing/validating analog to digital<br />
converters such as the NCI 901/902 and the Series<br />
900/900A Intelligent Interfaces. The module generates<br />
eight possible analog patterns at selectable voltage ranges<br />
of 0-0.1, 0-1, 0-2, and 0-10 V. Factory calibration is traceable<br />
to a NIST standard volt. Includes remote start/stop cable<br />
and analog signal cable for connection to PerkinElmer<br />
NCI/900/900A Series Intelligent Interfaces. Includes<br />
one-year return to Service Depot warranty.<br />
Voltage Part No. Each (€)<br />
120 V S9000160<br />
240 V S9000165 2586<br />
TotalChrom Workstation Model 520 IVM Software<br />
Allows user to test any NCI Series and M900A Series<br />
Intelligent Interfaces to validate interface operations<br />
(linearity, reproducibility, etc.). Contains special<br />
TotalChrom interface test methods and automated<br />
validation logs to maintain results of interface tests<br />
in software. Requires, but does not include, a Model 520<br />
Interface Validation Module.<br />
Part No. Each (€)<br />
Power Cords – 240 V<br />
N5150181 314<br />
Select appropriate power cord (No Charge) from list below. All 120 V<br />
interfaces include USA power cord. Canada, Japan, Taiwan, Puerto Rico,<br />
Bahamas, and most Latin American countries use 120 V interface version.<br />
Country Part No. Each (€)<br />
Australia, New Zealand 09991417 23<br />
Denmark, Greenland 09991416 27<br />
Europe, Saudi Arabia, Egypt, South Africa, 09991415 30<br />
India, Thailand, China<br />
Switzerland, Liechtenstein 09991413 25<br />
UK, Cyprus, Nigeria, Zimbabwe, 09991414 41<br />
Singapore, Malaysia, Zambia<br />
330
Software<br />
Serial Cables<br />
IEEE Cables<br />
All TC Versions<br />
Serial Cables<br />
Serial Cables for Instrument to dotLINK<br />
Cable Length Part No. Each (€)<br />
1 m 65105001 153<br />
2 m 65105102 173<br />
4 m 65105204 184<br />
8 m 65105408 230<br />
Connector Extender<br />
Extender attachment for use on computers where the PC<br />
case interferes with connection of the<br />
IEEE cable. Attaches to the IEEE board<br />
connector on back of PC case.<br />
Part No.<br />
09997196<br />
Each (€)<br />
73<br />
Serial Cables to Lantronix<br />
Terminal Server from<br />
TotalChrom Interfaces<br />
For M950/970 Interfaces<br />
7 ft. S5010017 32<br />
25 ft. S5010018 38<br />
50 ft. S5010019 51<br />
100 ft. S5010020 64<br />
For M941/M600 LINK Interfaces<br />
7 ft. S5010021 32<br />
25 ft. S5010022 38<br />
50 ft. S5010023 51<br />
100 ft. S5010024 64<br />
For NCI Interfaces<br />
7 ft. S5010037 63<br />
25 ft. S5010038 71<br />
50 ft. S5010039 64<br />
100 ft. S5010040 77<br />
Serial Cables to PC from<br />
TotalChrom Interfaces<br />
For M941 A and M600/610 Link Interfaces<br />
7 ft. S5010025 46<br />
25 ft. S5010030 52<br />
50 ft. S5010031 64<br />
100 ft. S5010032 77<br />
For dotLINK Interfaces<br />
10 ft. 09290144 19<br />
25 ft. 09290145 47<br />
For NCI Interfaces<br />
7 ft. S5010033 46<br />
25 ft. S5010034 52<br />
50 ft. S5010035 64<br />
100 ft. S5010036 77<br />
Description Part No. Each (€)<br />
Agilent 1100 HPLC to dotLINK, 10 ft. 09290144 19<br />
NCI Series to dotLINK S5010037 63<br />
for non-controlled detectors, 7 ft.<br />
PerkinElmer Series 200 Autosampler 09290149 9<br />
to dotLINK, 5 ft.<br />
PerkinElmer Series 200 Pump to dotLINK, 5 ft. 09290148 8<br />
PerkinElmer Series 200 UV/Vis to dotLINK, 5 ft. 09290149 9<br />
Serial Cables* for Instrument to M600 LINK<br />
Description Part No. Each (€)<br />
Agilent 1100 HPLC to M600/M610 LINK, 10 ft. S5010015 223<br />
Agilent 1100 HPLC to M600/M610 LINK, 25 ft. S5010016 300<br />
M900/960/970 Series Interface S5010013 223<br />
to M600/M610 LINK, 6 ft. (not for M941)<br />
NCI Series Interface to M600/M610 LINK, 6 ft. S5010041 223<br />
PerkinElmer ISS 200 Autosampler 09410015 159<br />
to M610 LINK, 6 ft.<br />
PerkinElmer Series 200 Autosampler N2930343 198<br />
to M610 LINK, 6 ft.<br />
PerkinElmer Model 250 Pump, Series 410 Pump 09410015 159<br />
to M610 LINK, 6 ft.<br />
PerkinElmer LC 235C Diode Array Detector 09410015 159<br />
to M610 LINK, 6 ft.<br />
PerkinElmer Series 200 Pump to M610 LINK, 6 ft. 09410020 187<br />
PerkinElmer Model 785A UV/Vis Detector 09410036 210<br />
to M610 LINK, 6 ft.<br />
PerkinElmer Series 200 UV/Vis Detector N2930343 198<br />
to M610 LINK, 6 ft.<br />
* Special serial cards, instrument communication kits, and IPM software<br />
may be required to complete interfacing of a LINK interface to a digital<br />
chromatograph. Please contact your local PerkinElmer Sales<br />
Representative for details.<br />
Software Liquid Chromatography<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
331
Software<br />
TotalChrom Software Kits<br />
Liquid Chromatography Software<br />
TotalChrom Optional Software<br />
Size Exclusion Software (TurboSEC)<br />
for TotalChrom Workstation<br />
TurboSEC provides calculation and reporting of weight<br />
average (Mw) or number average (Mn) molecular weight<br />
distributions. PolyDispersivity (Mw/Mn), z-average,<br />
viscosity average (Mv) and Intrinsic Viscosity. Slice reports,<br />
peak reports and Above/Below reports are also available.<br />
Plot options include SEC chromatograms, calibration plots,<br />
and overlays of cumulative Mw%, Mn%, Mz% averages on<br />
plots. Includes calibration using narrow or broad molecular<br />
weight standards with plots of log Mw vs. retention time of<br />
volume, nine calibration curve fit types, universal (integral)<br />
calibration, and retention time shift marker peak. User<br />
may draw baselines and processing limits are settable<br />
interactively through graphics.<br />
Requires TotalChrom or TurboChrom Part No. Each (€)<br />
Workstation v6.1 or higher.<br />
N5150183 1995<br />
Turbo Method Development Software<br />
for TotalChrom Workstation<br />
Turbo Method Development Software provides full binary,<br />
ternary, and quaternary mobile phase optimization by<br />
automatically searching mobile phase variables. Graphical<br />
displays of separation results indicate optimized area of<br />
separation. Also includes ruggedness testing with complete<br />
automation and documentation.<br />
Requires TotalChrom Workstation Part No. Each (€)<br />
v6.2 or higher software.<br />
N5150187 1596<br />
IRIS Spectral Processing Software<br />
for TotalChrom<br />
IRIS is an optional software program for spectral processing<br />
of data acquired from the PerkinElmer S200 Diode Array<br />
Detectors. Requires IPM for PerkinElmer LC Modules<br />
(N5150162) for control of S200. Also requires TotalChrom<br />
or TurboChrom 6.3.1 or higher.<br />
Part No. Each (€)<br />
TurboScan 200<br />
N5150130 1877<br />
TurboScan 200 is an optional software program for spectral<br />
processing of data aquired from the LC 235C PDA detector.<br />
Requires TurboChrom 6.1.x,<br />
TotalChrom 6.2.x or 6.3.0.<br />
Part No. Each (€)<br />
S2700055 2137<br />
TotalChrom Workstation Manuals<br />
Application Manager’s Guide<br />
Application Manager’s Guide covering<br />
installation and system management<br />
of TotalChrom Workstation software.<br />
Manual Set<br />
Complete manual set including User’s<br />
Guide (volumes 1 and 2), Application<br />
Manager’s Guide, and Tutorial.<br />
TotalChrom Tutorial<br />
Software tutorial that teaches basic data acquisition, method<br />
development, optimization techniques,<br />
sequence development, and calibration.<br />
Part No. Each (€)<br />
N5156021 70<br />
User’s Guide (Volumes 1 and 2)<br />
User’s Manual covering instrument<br />
configuration and basic operation<br />
of TotalChrom Workstation software.<br />
TotalChrom Workstation<br />
SI/DI Upgrade Kits<br />
TurboChrom Workstation Migration<br />
to TotalChrom v6.3.x Workstation<br />
Part No.<br />
Each (€)<br />
N5156025 128<br />
Part No.<br />
Each (€)<br />
N5150512 383<br />
Part No.<br />
Each (€)<br />
N5150518 255<br />
Migrates an existing TurboChrom Workstation v4.x 02 or<br />
v6.1.x acquisition system, and associated RPO systems, to<br />
TotalChrom Workstation v6.3.x software. Requires<br />
verification of ownership of<br />
TurboChrom software. Software<br />
supplied with CD-ROM media.<br />
Part No.<br />
N5150349<br />
Each (€)<br />
1140<br />
v6.2.x Workstation Migration to v6.3.x Workstation<br />
Migrates an existing TotalChrom v6.2.x acquisition system,<br />
and associated RPO Systems, to TotalChrom Workstation<br />
v6.3.x software. Requires verification of ownership of<br />
TotalChrom v6.2.x software. Software<br />
supplied with CD-ROM media.<br />
Part No. Each (€)<br />
N5150715 855<br />
332
PerkinElmer is the leader in<br />
high-sensitivity Thermal Analysis<br />
instrumentation, providing you the<br />
confidence to achieve fast, accurate,<br />
reproducible results. Our industryleading<br />
Thermal Analysis Pyris<br />
software and extensive range of<br />
Thermal Analysis accessories combine<br />
ease of use with needed flexibility,<br />
delivering solutions for a vast array of<br />
material property analyses.<br />
Thermal Analysis<br />
HyperDSC is the only true fastscan DSC<br />
technique, featuring scanning rates of up to<br />
500 °C/minute, giving you the ability to achieve fast,<br />
accurate, reproducible results. The technique is only<br />
available on the Diamond DSC from PerkinElmer and is<br />
used in many of the world’s leading pharmaceutical and<br />
polymer R&D laboratories because of its ability to provide<br />
information that previously may have gone undetected.
Thermal Analysis<br />
QUICK-FIND INDEX Page #<br />
DSC Autosampler Supplies<br />
and Accessories 345<br />
DSC High Pressure Cell<br />
and Supplies 346<br />
DSC Intracoolers and<br />
Subambient Accessories 347<br />
DSC Photocalorimeter<br />
Accessories and Supplies 349<br />
DSC Sample Holder Supplies 350<br />
DSC Sample Pan Crimpers 344<br />
DSC Sample Pans<br />
Quick Reference 336<br />
DTA Supplies and Accessories 353<br />
Laboratory Products<br />
and Accessories 354<br />
Mechanical Analysis:<br />
DMA Measuring Systems 356<br />
PerkinElmer offers a wide selection of superior quality products designed to work with<br />
your PerkinElmer instruments. Our precision-designed products deliver the peace of<br />
mind that comes from knowing that you’ll get the results you need.<br />
The Quick Find Index to the left will help you find products fast. For your convenience,<br />
products are alphabetized by category, sub-category, and family. There is also a more<br />
complete Alphabetical INDEX on page 429 and a Part Number INDEX on page 407.<br />
Aluminum Sample Pans and Covers<br />
Autosampler Sample Pans and Covers<br />
Used with nonvolatile solid samples, such as polymers<br />
and pharmaceuticals. Routinely used for applications such<br />
as polymer melting, crystallization, glass transitions of<br />
polymers, thermoplastics, and thermosets. Pans are<br />
crimped, but not hermetically sealed.<br />
Page 336<br />
The autosampler pans are available in sealed or<br />
vented versions. These pans may also be used for<br />
non-robotic systems.<br />
Page 338<br />
Mechanical Analysis:<br />
DMA/TMA Furnace Accessories 366<br />
Mechanical Analysis:<br />
TMA Measuring Systems 364<br />
Purge Gas Accessories 354<br />
TG/DTA Supplies<br />
and Accessories 367<br />
TGA Furnace and<br />
Furnace Accessories 369<br />
TGA Hangdown Wires,<br />
Sample Pans, and Supplies 371<br />
Thermal Analysis Software 373<br />
Ultramicrobalance Supplies 375<br />
Thermal Analysis Gas Station<br />
Universal Crimper Press<br />
The Thermal Analysis Gas Station provides full control<br />
of all gases used in thermal analysis. In addition to<br />
performing gas switching, it also fully controls the gas<br />
flow rate, and detects rapid changes in pressure and empty<br />
cylinders. The Thermal Analysis Gas Station controls up<br />
to four purge gases, uses calibrated massflow controls,<br />
and is easy to program.<br />
Page 355<br />
The Universal Crimper Press provides high quality pan<br />
sealing for the autosampler sample pans/hermetically<br />
sealed pans and can also crimp standard aluminum pans,<br />
large volume stainless steel (24 bar), and volatile pans.<br />
This is achieved simply by using the appropriate sealing<br />
insert. Includes sample pan suction tool and inserts to<br />
seal 10, 30, and 50 μL sample pans.<br />
Page 344
Differential Scanning Calorimeter (DSC)<br />
Thermal Analysis<br />
PerkinElmer is the leader in high sensitivity Thermal<br />
Analysis instrumentation, providing you the confidence to<br />
achieve fast, accurate, reproducible results. Our industryleading<br />
Thermal Analysis software and extensive range<br />
of Thermal Analysis accessories combine ease of use<br />
with needed flexibility, delivering solutions for a vast array<br />
of material property analyses. In addition to our power<br />
compensation Diamond DSC, PerkinElmer offers traditional<br />
heat flux DSC’s for less demanding applications.<br />
Diamond DSC<br />
The Diamond DSC is PerkinElmer’s unique powercompensation<br />
DSC, offering unparalleled sensitivity and<br />
insights into materials processes. In this exclusive design,<br />
the sample and reference pans are heated by two independent<br />
furnaces embedded in a temperature-controlled heat sink.<br />
This allows sophisticated analysis when performing the<br />
direct measurement of heat flow into or out of a sample.<br />
The Sapphire DSC<br />
The Sapphire DSC, the newest member of the PerkinElmer<br />
family of differential scanning calorimeters, is a heat flux<br />
DSC with broad temperature range and exceptional<br />
autosampler capabilities.<br />
The Sapphire DSC offers two inherent benefits because of<br />
its design: high sensitivity and excellent baseline stability.<br />
The unique heat flux oval sensor of the instrument<br />
provides extraordinary resolution and sensitivity and<br />
flat reproducible baselines.<br />
The power compensation DSC design leads to sharper<br />
peaks and high sensitivity. Additionally, benefits include<br />
true isothermal operation, modulated temperature DSC<br />
(StepScan) technique and HyperDSC for dramatic<br />
enhancements in sensitivity, as well as greater<br />
productivity. The Diamond DSC offers it all.<br />
The Diamond DSC features:<br />
■ Fastest heating and cooling rates<br />
■ Outstanding resolution<br />
■ Increased sensitivity<br />
■ True isothermal measurements<br />
■ High caloric accuracy<br />
Pyris 6 DSC<br />
The PYRIS TM 6 DSC is an ideal instrument for quality<br />
assurance/quality control and university laboratories.<br />
It performs routine experiments to characterize materials,<br />
predict product performance, optimize processing<br />
conditions, and improve quality.<br />
The PYRIS 6 DSC features:<br />
■ Exceptional value and performance<br />
■ Exceptional robustness and reliability<br />
■ Simple, inexpensive operation<br />
■ Space-saving footprint<br />
■ Easy-to-use Windows ® -based software<br />
Only PerkinElmer offers you a choice between two DSC<br />
models: a heat flux DSC and the power compensation DSC.<br />
No matter what your industry or application needs,<br />
PerkinElmer’s 40 years in the industry can offer the<br />
best solution for your analyses, based on your lab’s<br />
needs and budget.<br />
The Sapphire DSC features:<br />
■ Oval sensor for high resolution and sensitivity<br />
■ Highly reliable 50-position autosampler<br />
■ Multiple cooling options and pan types for broad operation range<br />
HyperDSC<br />
HyperDSC is the only true fastscan DSC technique,<br />
with scanning rates of up to 500 °C/min. The technique<br />
allows you to obtain additional, often crucial information,<br />
in seconds rather than minutes and is only available on<br />
the Diamond DSC from PerkinElmer.<br />
Many of the world’s leading pharmaceutical and polymer<br />
R&D laboratories have adopted the technique because of<br />
it’s ability to provide information that previously may<br />
have gone undetected. The HyperDSC technique makes<br />
it easier to study polymorphism in pharmaceuticals and<br />
realistically simulate polymer processing conditions. In<br />
addition, scientists are also exploring the use of<br />
HyperDSC in protein analyses.<br />
www.perkinelmer.com/<strong>supplies</strong> 335
DSC Sample Pans and Crimpers<br />
DSC Sample Pan Quick Reference<br />
Thermal Analysis DSC Sample Pans and Crimpers<br />
For use with Diamond DSC, Pyris 1 DSC, DSC 7, DSC 6, Pyris 6 DSC, and Jade DSC<br />
Aluminum<br />
Operating Maximum Crimper<br />
Sample Pan Range Vol. (μL) Pressure Quantity (Sealer) Part No. Page #<br />
Open/Crimped Pans<br />
Standard Aluminum Pans and Covers -170˚ to 600 ˚C 40 Ambient 400 02190048 or 02190041 342<br />
B0139005 with<br />
B0508921<br />
Aluminum Pans for Photocalorimetric Analysis -170˚ to 600 ˚C 12.5 Ambient 100 Not Required B0196858 341<br />
Aluminum Sample Pans -170˚ to 600 ˚C 28 Ambient 200 N5356027 N5356010 342<br />
N5356028<br />
Aluminum Sample Pans -170˚ to 600 ˚C 45 Ambient 400 N5356027 N5356012 342<br />
N5356028<br />
Aluminum Sample Pans, High Volume -170˚ to 600 ˚C 90 Ambient 200 N5356027 N5356034 342<br />
N5356028<br />
Aluminum Sample Pans for Photo DSC -170˚ to 600 ˚C 50 Ambient 400 Not Required N5356025 341<br />
Aluminum Sample Pans for HyperDSC -170˚ to 600 ˚C 50 Ambient 100 Not Required N5203115<br />
Vented/Pierced Pans<br />
Aluminum Covers (Pierced) -170˚ to 600 ˚C 0.05 mm hole 400 B7001014 338<br />
Volatile Aluminum Pans and Covers (Pierced) -170˚ to 600 ˚C 20 0.05 mm hole 100 02190061 or N5190788 346<br />
B0139005 with<br />
B0144637<br />
Aluminum (Vented) -170˚ to 600 ˚C 30 Vented 400 B0139005 B0143018 338<br />
Aluminum (Vented) -170˚ to 600 ˚C 50 Vented 400 B0139005 B0143019 338<br />
Hermetically Sealed/Volatile Pans<br />
Aluminum Pans -170˚ to 600 ˚C 10 1 bar 400 B0139005 B0143015 338<br />
Aluminum Pans -170˚ to 600 ˚C 30 1 bar 400 B0139005 B0143016 338<br />
Aluminum Pans -170˚ to 600 ˚C 50 1 bar 400 B0139005 B0143017 338<br />
Aluminum Pans and Covers -170˚ to 600 ˚C 20 2 bar 400 02190061 or 02190062 339<br />
B0139005 with<br />
B0144637<br />
Aluminum Pans and Covers -170˚ to 600 ˚C 10 3 bar 400 B0139005 B0169319 338<br />
Aluminum Pans and Covers -170˚ to 600 ˚C 30 3 bar 400 B0139005 B0169320 338<br />
Aluminum Pans and Covers -170˚ to 600 ˚C 50 3 bar 400 B0139005 B0169321 338<br />
Non-Coated Aluminum Sample Pans and Covers -170˚ to 500 ˚C 7.5 3 bar 200 N5356027 N5356008 339<br />
N5356028<br />
Alodined Aluminum Sample Pans and Covers -170˚ to 300 ˚C 7.5 3 bar 200 N5356027 N5356009 339<br />
N5356028<br />
Aluminum Sample Pans and Covers, Small Volume -170˚ to 500 ˚C 15 30 bar 40 N5356027 N5356003 340<br />
N5356028<br />
Aluminum Sample Pans and Covers, High Volume -170˚ to 500 ˚C 70 30 bar 40 N5356027 or N5356002 340<br />
N5356028<br />
Sample Pan Kits<br />
Aluminum Pan and Cover Starter Kit 3 bar 200/200 B0139005 B0510800<br />
Ceramic<br />
For use with Sapphire DSC<br />
Open/Crimped Pans<br />
Alumina Pans and Covers -170˚ to 730 ˚C 40 Ambient 6 Not Required N5190180 343<br />
Ceramic Sample Pans RT to 1500 ˚C 25 Ambient 5 Not Required N5356019 343<br />
Ceramic Sample Pans RT to 1500 ˚C 55 Ambient 2 Not Required N5356020 343<br />
336
DSC Sample Pans and Crimpers<br />
DSC Sample Pan Quick Reference<br />
For use with Diamond DSC, Pyris 1 DSC, DSC 7, DSC 6, Pyris 6 DSC, and Jade DSC<br />
Copper<br />
Operating Maximum Crimper<br />
Sample Pan Range Vol. (μL) Pressure Quantity (Sealer) Part No. Page #<br />
Open/Crimped Pans<br />
Standard Copper Pans and Covers -170˚ to 730 ˚C Ambient 200 02190048 03190026 342<br />
Copper Sample Pans -170˚ to 800 ˚C 45 Ambient 200 Not Required N5356021 342<br />
Gold<br />
Open/Crimped Pans<br />
Standard Gold Pans and Covers -170˚ to 730 ˚C 40 Ambient 10 02190048 02190042 342<br />
Hermetically Sealed/Volatile Pans<br />
Volatile Gold Pans and Covers -170˚ to 730 ˚C 20 2 bar 10 02190061 or 02190080 339<br />
B0139005 with<br />
B0144637<br />
High Pressure Gold-Plated Pans and Covers -170˚ to 400 ˚C 30 150 bar 5 B0182864 B0182902 340<br />
Graphite<br />
Open/Crimped Pans<br />
Graphite Pans and Covers -170˚ to 730 ˚C 40 Ambient 4 Not Required 03190025 343<br />
Platinum<br />
Open/Crimped Pans<br />
Platinum Pans and Covers -170˚ to 730 ˚C 40 Ambient 4 Not Required 03190024 343<br />
Platinum Sample Pans -170˚ to 1500 ˚C 45 Ambient 5 Not Required N5356016 343<br />
Platinum Sample Pans -170˚ to 1500 ˚C 95 Ambient 5 Not Required N5356017 343<br />
Silver<br />
Hermetically Sealed/Volatile Pans<br />
Silver Sample Pans and Covers (Small Volume) -170˚ to 600 ˚C 15 50 bar 20 N5356027 N5356005 340<br />
N5356028<br />
Silver Sample Pans and Covers (High Volume) -170˚ to 600 ˚C 70 50 bar 20 N5356027 N5356004 340<br />
N5356028<br />
Stainless Steel<br />
Hermetically Sealed/Volatile Pans<br />
Stainless Steel Pans, Covers, and O-Rings -40˚ to 300 ˚C 60 24 bar 20 09908467 or 03190218 340<br />
B0139005 with<br />
B0505340<br />
Stainless Steel Pans, Covers, and O-Rings -40˚ to 300 ˚C 60 24 bar 1000 09908467 or 03190029 340<br />
B0139005 with<br />
B0505341<br />
High Pressure Stainless Steel Pans and Covers -170˚ to 400 ˚C 30 150 bar 5 B0182864 B0182901 340<br />
Stainless Steel Sample Pans and Covers (Small Vol.) -170˚ to 800 ˚C 15 50 bar 20 N5356027 N5356007 340<br />
N5356028<br />
Stainless Steel Sample Pans and Covers (High Vol.) -170˚ to 800 ˚C 70 50 bar 20 N5356027 N5356006 340<br />
N5356028<br />
Titanium<br />
For use with Sapphire DSC<br />
Open/Crimped Pans<br />
High Pressure Titanium Pans and Covers -170˚ to 400 ˚C 30 150 bar 5 B0182864 B0182903 340<br />
DSC Sample Pans and Crimpers Thermal Analysis<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
337
DSC Sample Pans and Crimpers<br />
Autosampler Sample Pan and Covers<br />
Thermal Analysis DSC Sample Pans and Crimpers<br />
For use with Diamond DSC, Pyris 1 DSC, DSC 7, DSC 6, Pyris 6 DSC, and Jade DSC<br />
Autosampler Sample Pans and Covers<br />
The autosampler pans are available in sealed or vented versions. These pans may also be used for non-robotic systems.<br />
Operating Maximum Crimper<br />
Sample Pan Range Vol. (μL) Pressure Quantity (Sealer) Part No. Each (€)<br />
Aluminum (Vented) 1 -170˚ to 600 ˚C 30 Vented 400 B0139005 B0143018 289<br />
Aluminum (Vented) 1 -170˚ to 600 ˚C 50 Vented 400 B0139005 B0143019 237<br />
Aluminum Pans 1, 2 -170˚ to 600 ˚C 10 1 bar 400 B0139005 B0143015 237<br />
Aluminum Pans 1, 2 -170˚ to 600 ˚C 30 1 bar 400 B0139005 B0143016 289<br />
Aluminum Pans 1, 2 -170˚ to 600 ˚C 50 1 bar 400 B0139005 B0143017 237<br />
Aluminum Covers 3 -170˚ to 600 ˚C 400 B0143003 237<br />
Aluminum Pans and Covers 2 -170˚ to 600 ˚C 10 3 bar 400 B0139005 B0169319 970<br />
Aluminum Pans and Covers 2 -170˚ to 600 ˚C 30 3 bar 400 B0139005 B0169320 970<br />
Aluminum Pans and Covers 2 -170˚ to 600 ˚C 50 3 bar 400 B0139005 B0169321 970<br />
Aluminum Covers (Pierced) 4 -170˚ to 600 ˚C 0.05 mm hole 400 B7001014 422<br />
Aluminum Sample Pans 2, 5 -170˚ to 600 ˚C 28 Ambient 200 N5356027 N5356010 174<br />
N5356028<br />
Aluminum Sample Pans 6 -170˚ to 600 ˚C 45 Ambient 400 N5356027 N5356012 269<br />
N5356028<br />
1<br />
Require Covers (B0143003)<br />
2<br />
Can be used with all Autosamplers<br />
3<br />
For use with (B0143015, B0143016, B0143017, B0143018, and B0143019)<br />
4<br />
For use with (B0169319, B0169320, and B0169321)<br />
5<br />
Requires Autosampler Pan Die and Stage (N5356031)<br />
6<br />
Cover Plate style (N5356015)<br />
For use with Sapphire DSC<br />
338
DSC Sample Pans and Crimpers<br />
Hermetically Sealed Sample Pans (up to 3 bar)<br />
For use with Diamond DSC, Pyris 1 DSC, DSC 7, DSC 6, Pyris 6 DSC, and Jade DSC<br />
Hermetically Sealed Sample Pans (up to 3 bar)<br />
Hermetically sealed sample pans are used with volatile<br />
solid or liquid samples which exert significant vapor<br />
pressure at the temperature of interest. Available in both<br />
aluminum and gold pans.<br />
Pans can withstand an internal pressure up to 3 bar<br />
The heats of fusion of materials which sublime can be<br />
determined accurately<br />
The effect of an enclosed atmosphere on thermal behavior<br />
of a sample can be observed<br />
Capsules have an effective volume of up to 50 microliters<br />
Gold pans are available for samples requiring temperatures<br />
above 600 °C<br />
For use with Sapphire DSC<br />
Operating Maximum Crimper<br />
Sample Pan Range Vol. (μL) Pressure Quantity (Sealer) Part No. Each (€)<br />
Aluminum Pans 1, 2 -170˚ to 600 ˚C 10 1 bar 400 B0139005 B0143015 237<br />
Aluminum Pans 1, 2 -170˚ to 600 ˚C 30 1 bar 400 B0139005 B0143016 289<br />
Aluminum Pans 1, 2 -170˚ to 600 ˚C 50 1 bar 400 B0139005 B0143017 237<br />
Aluminum Covers 3 -170˚ to 600 ˚C 400 B0143003 237<br />
Aluminum Pans and Covers 2 -170˚ to 600 ˚C 10 3 bar 400 B0139005 B0169319 970<br />
Aluminum Pans and Covers 2 -170˚ to 600 ˚C 30 3 bar 400 B0139005 B0169320 970<br />
Aluminum Pans and Covers 2 -170˚ to 600 ˚C 50 3 bar 400 B0139005 B0169321 970<br />
Non-Coated Aluminum Sample Pans and Covers 5 -170˚ to 500 ˚C 7.5 3 bar 200 N5356027 N5356008 333<br />
N5356028<br />
Alodined Aluminum Sample Pans and Covers 5 -170˚ to 300 ˚C 7.5 3 bar 200 N5356027 N5356009 476<br />
N5356028<br />
Volatile Aluminum Pans and Covers 4 -170˚ to 600 ˚C 20 2 bar 400 02190061 or 02190062 443<br />
B0139005 with<br />
B0144637<br />
Volatile Gold Pans and Covers -170˚ to 730 ˚C 20 2 bar 10 02190060 or 02190080 1078<br />
B0139005 with<br />
B0144637<br />
1<br />
Require Covers (B0143003)<br />
2<br />
Can be used with all Autosamplers<br />
3<br />
For use with (B0143015, B0143016, and B0143017)<br />
4<br />
Can be used with all Mechanical Autosamplers<br />
5<br />
Requires Die (N5356036) and Stage (N5356035)<br />
Major Applications<br />
Purity analyses (i.e., pharmaceuticals, melting of lipids,<br />
or liquid crystals)<br />
Phase transitions, heat of vaporization, and boiling points<br />
DSC Sample Pans and Crimpers Thermal Analysis<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
339
DSC Sample Pans and Crimpers<br />
High Pressure Sample Pans (24 to 150 bar)<br />
Thermal Analysis DSC Sample Pans and Crimpers<br />
For use with Diamond DSC, Pyris 1 DSC, DSC 7, DSC 6, Pyris 6 DSC, and Jade DSC<br />
High Pressure Sample Pans (24 to 150 bar)<br />
Pans contain the sample in a sealed environment throughout<br />
an experiment. The sealing suppresses the vaporization of a<br />
solvent or contains a volatile reaction product, thereby<br />
eliminating the interfering effects of the heat of vaporization.<br />
Stainless Steel Pans with O-Ring:<br />
Sealed pans prevent any mass loss<br />
Pans can withstand an internal pressure of 24 bar<br />
High internal pressure capability allows water samples<br />
to be heated higher than 100 °C<br />
Large sample capacity yields higher sensitivity<br />
Operating range of -40° to 300 °C, unless otherwise<br />
limited by sample vapor pressure<br />
Under no circumstances should<br />
the pans be heated above 300 °C.<br />
Any application requiring<br />
the heating beyond 200 °C or<br />
where gaseous decomposition<br />
products may be generated<br />
should first be tested outside<br />
of the instrument.<br />
Major Applications<br />
For use with Sapphire DSC<br />
Operating Maximum Crimper<br />
Sample Pan Range Vol. (μL) Pressure Quantity (Sealer) Part No. Each (€)<br />
Aluminum Sample Pans and Covers, High Volume 3 -170˚ to 500 ˚C 70 30 bar 40 N5356027 N5356002 333<br />
N5356028<br />
Aluminum Sample Pans and Covers, Small Volume 3 -170˚ to 500 ˚C 15 30 bar 40 N5356027 N5356003 333<br />
N5356028<br />
Gold-Plated Pans, Covers, and Seals 1 -170˚ to 400 ˚C 30 150 bar 5 B0182864 B0182902 950<br />
Stainless Steel Pans, Covers, and Seals 1 -170˚ to 400 ˚C 30 150 bar 5 B0182864 B0182901 228<br />
Titanium Pans, Covers, and Seals 2 -170˚ to 400 ˚C 30 150 bar 5 B0182864 B0182903 1218<br />
Silver Sample Pans and Covers, High Volume 3 -170˚ to 600 ˚C 70 50 bar 20 N5356027 N5356004 445<br />
N5356028<br />
Silver Sample Pans and Covers, Small Volume 3 -170˚ to 600 ˚C 15 50 bar 20 N5356027 N5356005 412<br />
N5356028<br />
Stainless Steel Pans, Covers, and O-Rings -40˚ to 300 ˚C 60 24 bar 20 B0139005 with 03190218 176<br />
B0505340<br />
Stainless Steel Pans, Covers, and O-Rings -40˚ to 300 ˚C 60 24 bar 1000 B0139005 with 03190029 4363<br />
B0505340<br />
Stainless Steel Sample Pans and Covers (Small Vol.) -170˚ to 800 ˚C 15 50 bar 20 N5356027 N5356007 412<br />
N5356028<br />
Stainless Steel Sample Pans and Covers (High Vol.) -170˚ to 800 ˚C 70 50 bar 20 N5356027 N5356006 412<br />
N5356028<br />
1<br />
Reusable, includes 5 Pans and 20 Gold-Plated Seals, uses Replacement Seals (B0182905)<br />
2<br />
Reusable, includes 5 Pans and 20 Titanium Seals, uses Replacement Seals (B0185054)<br />
3<br />
Electric Sealer (N5356028) requires Hermetic Die (N5356032) and Stage (N5356035), included with Manual Sealer<br />
The study of aqueous biological solutions (such as protein<br />
in water) where the dilution requires large sample sizes<br />
and water vaporization must be suppressed<br />
Epoxy phenolic curing and vulcanization of rubber where the<br />
loss of volatiles can otherwise make interpretation difficult<br />
Reusable 150 Bar High Pressure Pans<br />
These reusable capsules can contain up to 150 bar. Their<br />
unique design includes a bursting disk on the cover of the<br />
capsule which allows the sample to safely vent if the pressure<br />
should exceed 150 atmospheres.<br />
The use of high pressure capsules in DSC permits<br />
suppressing the endothermic signal resulting from the<br />
volatilization of sample material or from the volatilization<br />
or decomposition of reaction by-products<br />
High pressure capsules permit the study of explosive materials<br />
and can be used in any situation where the advantage of a<br />
self-generating atmosphere is to be employed<br />
Capsules available in steel, gold-plated steel, and titanium<br />
Can withstand a maximum internal pressure up to 150 bar<br />
Capsules are reusable after sealing<br />
Used in hazard testing, curing reactions<br />
340
DSC Sample Pans and Crimpers<br />
Large Volume Pans (55 to 90 μL) and Photo DSC Sample Pans<br />
For use with Diamond DSC, Pyris 1 DSC, DSC 7, DSC 6, Pyris 6 DSC, and Jade DSC<br />
Large Volume Sample Pans (55 to 90 μL)<br />
Operating Maximum Crimper<br />
Sample Pan Range Vol. (μL) Pressure Quantity (Sealer) Part No. Each (€)<br />
Aluminum Sample Pans 1 -170˚ to 600 ˚C 90 open 200 N5356027 N5356034 286<br />
N5356028<br />
Aluminum Sample Pans and Covers 1 -170˚ to 500 ˚C 70 30 bar 40 N5356027 N5356002 333<br />
N5356028<br />
Ceramic Sample Pans RT to 1500 ˚C 55 open 2 Not Required N5356020 333<br />
Stainless Steel Pans, Covers, and O-Rings -40˚ to 300 ˚C 60 24 bar 20 B0139005 with 03190218 176<br />
B0505340<br />
Stainless Steel Pans, Covers, and O-Rings -40˚ to 300 ˚C 60 24 bar 1000 B0139005 with 03190029 4363<br />
B0505340<br />
1<br />
Electric Sealer (N5356028) requires Hermetic Die (N5356032) and Stage (N5356035)<br />
Large Volume Stainless<br />
Steel Capsule Kit<br />
Part No.<br />
Each (€)<br />
03190021 1875<br />
Kit Includes: Part No. Each (€)<br />
Quick Press 09908467 1301<br />
Quick Press Spacer Die 03191047 140<br />
Guard Ring Inserts, 1 pair 03190236 134<br />
20 Pans, Covers, and O-Rings 03190218 176<br />
Photo DSC Pans<br />
For use with Sapphire DSC<br />
Large Volume and Volatile Sample Pans<br />
Large Volume Stainless Steel Pans are designed for high pressure, large capacity analysis. Capsules contain the sample in a<br />
sealed environment throughout an experiment. The Viton TM O-Ring allows formation of a seal which suppresses the vaporization<br />
of a solvent or contains a volatile reaction product, thereby eliminating the interfering effects of the heat of vaporization.<br />
The photocalorimetric accessory extends the use of the Diamond DSC and permits to quantitatively measure the enthalpy<br />
changes (heat flow) in a material during and after exposure to UV light.<br />
Operating Maximum Crimper<br />
Sample Pan Range Vol. (μL) Pressure Quantity (Sealer) Part No. Each (€)<br />
Aluminum Pans for Photocalorimetric Analysis -170˚ to 600 ˚C 12.5 Ambient 100 Not Required B0196858 550<br />
Pans and Quartz Covers -170˚ to 600 ˚C 12.5 Ambient 100 Not Required B0198030 1469<br />
Quartz Covers 10 B0181091 93<br />
Aluminum Sample Pans for Photo DSC 1 -170˚ to 600 ˚C 50 Ambient 400 Not Required N5356025 238<br />
Aluminum Covers for Photo DSC 2 -170˚ to 600 ˚C 400 N5356026 238<br />
1<br />
For thin samples with Photo DSC (PDC121)<br />
2<br />
For thin Sample Pan (N5356025) with Photo DSC (PDC121)<br />
DSC Sample Pans and Crimpers Thermal Analysis<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
341
DSC Sample Pans and Crimpers<br />
Open Sample Pans<br />
Thermal Analysis DSC Sample Pans and Crimpers<br />
For use with Diamond DSC, Pyris 1 DSC, DSC 7, DSC 6, Pyris 6 DSC, and Jade DSC<br />
Open Sample Pans<br />
PerkinElmer offers sample pans to satisfy the needs of<br />
most thermal analysts. Ambient sample pans are available<br />
in aluminum, copper, or gold with the option for crimping.<br />
For special applications you can chose from alumina/<br />
ceramic, platinum, or graphite pans.<br />
In the crimped standard sample pan, the sample is completely<br />
enclosed in a highly conductive capsule and distributed in a<br />
thin layer such that the internal resistance in the sample<br />
itself is very small<br />
Due to the high thermal conductivities of aluminum, copper,<br />
and gold, heat transfer is maximized. This means that sample<br />
size can be minimized<br />
Because of their high-temperature capabilities, platinum and<br />
gold can be used to 730 °C<br />
Aluminum Copper Gold<br />
1<br />
Not for use with Diamond DSC, PYRIS 1 DSC, or DSC 7 Autosampler<br />
2<br />
Cover (N5356011)<br />
3<br />
Can be used with Autosampler, requires Autosampler Pan Die and Stage (N5356031)<br />
4<br />
Cover Crimp style (N5356014). Not for DSC Autosampler, requires Crimping Die and Stage (N5366030)<br />
5<br />
Cover Plate style (N5356015)<br />
6<br />
Copper Mesh Cover (N5356022)<br />
7<br />
Stainless Steel Mesh Cover (N5356023)<br />
8<br />
Recommended for O.I.T. tests<br />
For use with Sapphire DSC<br />
Aluminum Sample Pans and Covers<br />
Used with nonvolatile solid samples, such as polymers<br />
and pharmaceuticals. Routinely used for applications<br />
such as polymer melting, crystallization, glass transitions<br />
of polymers, thermoplastics, and thermosets. Pans are<br />
crimped but not hermetically sealed.<br />
Copper Sample Pans and Covers<br />
Can be used for samples that have transitions that occur<br />
above the temperature range of the aluminum pans.<br />
Typical applications include antioxidant testing (O.I.T.),<br />
thermoset and thermoplastic glass transition, and melting<br />
point determinations.<br />
Gold Sample Pans and Covers<br />
Used for any non-metal, i.e., ceramics, coal, soils, or<br />
minerals. Can also be used for any material that reacts<br />
with aluminum or which must be heated over 600 °C.<br />
Operating Maximum Crimper<br />
Sample Pan Range Vol. (μL) Pressure Quantity (Sealer) Part No. Each (€)<br />
Standard Aluminum Pans and Covers 1 -170˚ to 600 ˚C 40 Ambient 400 02190048 or 02190041 434<br />
B0139005 with<br />
B0508921<br />
Standard Copper Pans and Covers 1 -170˚ to 730 ˚C 40 Ambient 200 02190048 03190026 297<br />
Standard Gold Pans and Covers 1 -170˚ to 730 ˚C 40 Ambient 10 02190048 02190042 2035<br />
Aluminum Sample Pans 2, 3 -170˚ to 600 ˚C 28 Ambient 200 N5356027 N5356010 174<br />
N5356028<br />
Aluminum Sample Pans 4, 5 -170˚ to 600 ˚C 45 Ambient 400 N5356027 N5356012 269<br />
N5356028<br />
Aluminum Sample Pans, High Volume 4, 5 -170˚ to 600 ˚C 90 Ambient 200 N5356027 N5356034 286<br />
N5356028<br />
Copper Sample Pans 6, 7, 8 -170˚ to 800 ˚C 45 Ambient 200 Not Required N5356021 255<br />
342
DSC Sample Pans and Crimpers<br />
Open Sample Pans<br />
For use with Diamond DSC, Pyris 1 DSC, DSC 7, DSC 6, Pyris 6 DSC, and Jade DSC<br />
Alumina/Ceramic Sample Pans and Covers<br />
Used for oxidation studies of metals, minerals, ceramics,<br />
clays, and soils. They can also be used for melting and<br />
eutectic diagrams in the metals industry. The covers are<br />
pierced. A crimper is not required.<br />
Graphite Sample Pans and Covers<br />
Use in an inert atmosphere. They are primarily used with<br />
metals, but not for oxidation studies. They have extremely<br />
good heat transfer properties which yield sharp transition<br />
curves. A crimper is not required.<br />
Platinum Sample Pans and Covers<br />
Use these pans and covers when gold and graphite pans and<br />
covers are not suitable. Used to analyze mineral, soil, and<br />
ceramic samples. They are also used to allow a chemical<br />
reaction where platinum acts as a catalyst. They are easy to<br />
clean and reusable. A crimper is not required.<br />
For use with Sapphire DSC<br />
Operating Maximum Crimper<br />
Sample Pan Range Vol. (μL) Pressure Quantity (Sealer) Part No. Each (€)<br />
Alumina Pans and Covers -170˚ to 730 ˚C 40 Ambient 6 Not Required N5190180 395<br />
Ceramic Sample Pans 1 RT to 1500 ˚C 25 Ambient 5 Not Required N5356019 174<br />
Ceramic Sample Pans 1 RT to 1500 ˚C 55 Ambient 2 Not Required N5356020 333<br />
Graphite Pans and Covers -170˚ to 730 ˚C 40 Ambient 4 Not Required 03190025 297<br />
Platinum Pans and Covers* -170˚ to 730 ˚C 40 Ambient 4 Not Required 03190024 950<br />
Platinum Sample Pans 2 -170˚ to 1500 ˚C 45 Ambient 5 Not Required N5356016 507<br />
Platinum Sample Pans, High Volume 2 -170˚ to 1500 ˚C 95 Ambient 5 Not Required N5356017 507<br />
1<br />
No Covers<br />
2<br />
Plate Covers (N5356018)<br />
* While Supplies Last<br />
Alumina/Ceramic<br />
Graphite<br />
Platinum<br />
DSC Sample Pans and Crimpers Thermal Analysis<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
343
DSC Sample Pans and Crimpers<br />
Universal Crimpers<br />
Thermal Analysis DSC Sample Pans and Crimpers<br />
For use with Diamond DSC, Pyris 1 DSC, DSC 7, DSC 6, Pyris 6 DSC, and Jade DSC<br />
Crimpers and Sealers<br />
High-Pressure Capsule Sealing Tool<br />
Quick Press<br />
For use with: Seal Pans (03190218<br />
and 03190029) and requires<br />
Spacer Die (03191047).<br />
This reliable sealing tool is fast<br />
and precise. It employs a built-in<br />
torque clutch which guarantees<br />
that all capsules are closed with<br />
the same torque.<br />
For use with: Seal Pans (B0182901,<br />
B0182902, and B0182903).<br />
Standard Sample Pan Crimper Press<br />
Used to crimp covers on standard DSC pans of<br />
aluminum, gold, and copper. Design incorporates a<br />
replaceable crimper head.<br />
For use with: Crimp Pans (02190041 and 03190026)<br />
and Replacement Crimper Head (02191171).<br />
Crimpers for Sapphire DSC Pans<br />
Universal Crimper Press<br />
For use with Sapphire DSC<br />
The Universal Crimper Press provides high quality pan<br />
sealing for the autosampler sample pans/Hermetically<br />
sealed pans and can also crimp standard aluminum pans,<br />
large volume stainless steel (24 bar), and volatile pans.<br />
This is achieved simply by using the appropriate sealing<br />
insert. Includes sample pan suction tool and inserts to<br />
seal 10, 30, and 50 μL sample pans.<br />
Requires:<br />
Insert (B0144637) for Volatile Sample Pans (02190062,<br />
02190080, and N5190788), Insert (B0505340) for Stainless<br />
Steel Pans (03190218 and 03190029), Insert (B0508921) for<br />
Standard Aluminum Pans (02190041),<br />
and Insert (B0139033) for Hermetically Part No. Each (€)<br />
10, 30, and 50 μL Pans included.<br />
B0139005 2328<br />
Description Crimper (Sealer) Part No. Each (€)<br />
Manual Sample Pan Crimper (Sealer) with Die and Stage, Includes Hermetic Die (N5356032), N5356027 2381<br />
Stage (N5356035), and Extruding Rod (N5356033)<br />
Part No.<br />
Each (€)<br />
B0182864 1951<br />
Part No.<br />
Each (€)<br />
09908467 1301<br />
Part No.<br />
Each (€)<br />
02190048 1742<br />
Electric Driven Sample Pan Crimper (Sealer) without Die and Stage, Requires Die and Stage N5356028 6000<br />
Die and Stage for Crimpable Sample Pan, Seal Pans (N5356012 and N5356034) N5356027 or N5356030 1403<br />
N5356028<br />
Die and Stage for Autosampler Sample Pan, Seal Pans (N5356010) N5356027 or N5356031 225<br />
N5356028<br />
Die for Hermetic Sample Pan, Seal all Pans 30 and 50 bar, included in manual Standard Pan Crimper N5356028 N5356032 311<br />
Stage for Hermetic Sample Pan, Required for Hermetic Die (N5356032) or Die for Simple N5356028 N5356035 429<br />
Seal (N5356036), included with Manual Sample Pan Crimper<br />
Die for Simple Seal, Seals Pans (N5356008 and N5356009), requires Stage for Hermetic Seal (N5356035) N5356027 or N5356036 251<br />
N5356028<br />
Extruding Rod for Hermetic Sample Pan Sealer, For Hermetic Sample Pan Sealer N5356027 or N5356033 530<br />
N5356028<br />
344
DSC Supplies and Accessories<br />
Autosampler Supplies and Accessories<br />
PerkinElmer Diamond DSC Autosampler provides the<br />
automation, convenience, and flexibility you need!<br />
Allows automated DSC testing of up to 48 samples<br />
for the PYRIS 1 DSC and 44 samples for the Diamond DSC<br />
without operator attention<br />
Handles 10, 30, and 50 μL sealed pans and vented (open)<br />
pans as well as high pressure capsules<br />
Complete software control from a computer keyboard<br />
simplifies operation<br />
Diamond DSC, PYRIS 1 DSC<br />
Autosampler, and DSC 7 Robotic<br />
System Supplies and Accessories<br />
Magazine Kit B0142511 695<br />
Set of 12 magazines.<br />
Platinum Cover for Sample and B0139122 186<br />
Reference Cells, two required.<br />
1 Slide Key B0139120 166<br />
One end is magnetized for easy removal of magazines from the<br />
sample carousel. Other end (not magnetic) is used to insert<br />
magazines in sample carousel.<br />
Used to insert and remove the sample magazine through the<br />
access port in the cover<br />
Inserting magazines with the slide key prevents humidity and<br />
dust from entering the working space when changing samples<br />
2 Special Sample Pan Manipulator B0142512 300<br />
Specially designed to simplify the pickup and positioning of<br />
your sample pans and covers<br />
Stainless steel handle incorporates suction device<br />
5 Standard Sample Pan Manipulator B0143263 74<br />
Prevents contamination of your sample<br />
Simplifies the handling of your sample pans and covers<br />
Replacement Rubber Tip<br />
Used on the Sample Pan Manipulators, the Autosampler<br />
Sample Arm, and the Robotic system. Replace the rubber<br />
tip regularly for reliable operation.<br />
Part No. Each (€)<br />
Large Platinum Furnace Cover<br />
Used when running sample specimens<br />
in large volume stainless steel pans<br />
with the Autosampler. Two required.<br />
N5376097 29<br />
Part No.<br />
Each (€)<br />
B0182981 668<br />
Diamond DSC Autosampler<br />
Sample Preparation Recommendations<br />
2<br />
Never touch your sample, sample pan,<br />
sample cover, or platinum cover with your bare<br />
fingers. Body oils and greases may cause<br />
contamination and erroneous results.<br />
1<br />
DSC Supplies and Accessories Thermal Analysis<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
345
DSC Supplies and Accessories<br />
DSC High Pressure Cells and Accessories<br />
Thermal Analysis DSC Supplies and Accessories<br />
DSC High Pressure Cell Part No. N5200001<br />
Accessories<br />
Replacement Sample Holder<br />
for DSC High Pressure Cell<br />
Replacement sample holder for use with the DSC High<br />
Pressure Cell tested to meet all<br />
temperature and pressure specifications. Part No. Each (€)<br />
O-Ring for DSC High Pressure<br />
Cell Enclosure Cover<br />
Aluminum Sample Holder Cover<br />
for DSC High Pressure Cell<br />
Glass Wool Pads<br />
for DSC High Pressure Cell<br />
Sample Handling Tray<br />
for DSC High Pressure Cell<br />
Vapor Pressure Pan Kit<br />
N0200015 1073<br />
Part No.<br />
Each (€)<br />
B0199379 1<br />
Part No.<br />
Each (€)<br />
B0500724 140<br />
Part No.<br />
Each (€)<br />
B0500722 98<br />
Part No.<br />
Each (€)<br />
N5201016 148<br />
This kit includes 100 volatile aluminum pans and 100 pierced<br />
covers. A 50-micron diameter hole is centered in the cover.<br />
Use this kit for more reproducible measurements of boiling<br />
points, heats of vaporization, and sublimation temperatures.<br />
Vapor pressure studies can be conducted when using these<br />
pans and covers with the High Pressure DSC or the TGA.<br />
Maximum temperature is 600 °C. Use Sealer (02190061) or<br />
Universal Press (B0139005) with<br />
Sealing Insert (B0144637). 100 of each. Part No. Each (€)<br />
N5190788 300<br />
DSC High Pressure Cells<br />
The DSC High Pressure Cell is an accessory for performing<br />
DSC experiments at elevated pressure. The accessory<br />
operates with the Differential Scanning Calorimeters that<br />
use the unique PerkinElmer power compensated principle.<br />
Pressure range is 42 bar (600 psi) maximum; temperature<br />
range is 40° to 600 °C.<br />
Typical applications include:<br />
Oxidation testing of oils, fats, foods, and plastics<br />
Curing and crosslinking reactions<br />
Suppression of evaporation of volatiles<br />
Analysis of pressure-dependent chemical reactions<br />
There are built-in connections for a liquid cooling system<br />
(tap water or circulating system). PerkinElmer Service<br />
installation is recommended.<br />
Diamond DSC High Pressure Cell Kit<br />
Includes: DSC High Pressure Cell<br />
(N5200001) and Diamond DSC High<br />
Pressure Connection Kit (N5360321).<br />
Diamond DSC Connection Kit<br />
Upgrade kit for existing DSC 7<br />
customers who need to use DSC 7<br />
High Pressure Cell on Diamond DSC.<br />
DSC 7, DSC-4, and DSC-2<br />
High Pressure Cell<br />
Pyris 1 DSC High Pressure Cell Kit<br />
Includes: DSC High Pressure Cell<br />
(N5200001) and PYRIS 1 DSC High<br />
Pressure Connection Kit (N5370298).<br />
Part No.<br />
PYRIS 1 DSC High Pressure Connection Kit<br />
Each (€)<br />
N5360188 15700<br />
Part No.<br />
Each (€)<br />
N5360321 708<br />
Part No.<br />
Each (€)<br />
N5200001 14200<br />
Part No.<br />
Each (€)<br />
N5370299 15700<br />
Upgrade for existing DSC 7 or DSC 4 customers who need<br />
to use the High Pressure Cell<br />
(N5200001) on the PYRIS 1 DSC. Part No. Each (€)<br />
N5370298 708<br />
346
DSC Supplies and Accessories<br />
Intracoolers and Subambient Accessories<br />
Intracoolers<br />
Intracoolers from PerkinElmer are subambient devices<br />
that automatically control the flow of coolant through a<br />
circulating chamber attached to the Diamond DSC, PYRIS 1<br />
DSC, PYRIS 6 DSC, Sapphire DSC, DSC 7, TMA 7, or DMA 7<br />
analyzers. They are either single or dual-stage mechanical<br />
compression refrigeration units with a cylindrical expansion<br />
chamber and special bolts and insulation for mounting<br />
directly on the sample holder block of the Diamond DSC,<br />
PYRIS 1 DSC, PYRIS 6 DSC, and DSC 7, or the furnace<br />
assembly of the DMA 7 or TMA 7.<br />
Diamond DSC/PYRIS 1 DSC Intracooler 1P<br />
Allows for subambient operation to -30 °C.<br />
Voltage Part No. Each (€)<br />
115 V, 50/60 Hz N5370205<br />
230 V, 50/60 Hz N5370206 3290<br />
Diamond DSC/PYRIS 1 DSC Intracooler 2P<br />
Allows for subambient operation to -65 °C.<br />
Voltage Part No. Each (€)<br />
115 V, 50/60 Hz N5370207 6700<br />
230 V, 50/60 Hz N5370208 6700<br />
DSC 7 Intracooler 1<br />
Allows for subambient operation to -30 °C.<br />
Voltage Part No. Each (€)<br />
115 V, 50/60 Hz 03190205 3456<br />
230 V, 50/60 Hz 03190206 3456<br />
DSC 7 Intracooler 2<br />
Allows for subambient operation to -65 °C.<br />
Voltage Part No. Each (€)<br />
115 V, 50/60 Hz 03190207 6611<br />
230 V, 50/60 Hz 03190208 6700<br />
Intracooler SP Kit for Sapphire DSC<br />
Allows for subambient operation to -70 °C.<br />
Voltage Part No. Each (€)<br />
115 V N5350130 6700<br />
220 V N5350131 6700<br />
PYRIS 6 DSC Intracooler<br />
Allows for subambient operation to -80 °C.<br />
Voltage Part No. Each (€)<br />
115 V, 50/60 Hz N5374098 6700<br />
230 V, 50/60 Hz N5374099 6700<br />
PYRIS 6 DSC with Intracooler Hose Part No. N5374098<br />
Intracooler Spares<br />
Intracooler Bolt Kit for the Diamond<br />
DSC/PYRIS 1 DSC and DSC 7<br />
Includes: Part No. Each (€)<br />
Intracooler Bolt Insulating Disk 03191720 37<br />
Split Bushing 03191719 22<br />
Bolt 03191527 111<br />
Subambient Accessories for<br />
Diamond DSC/PYRIS 1 DSC<br />
Diamond DSC/PYRIS 1 DSC<br />
Part No.<br />
Each (€)<br />
03190247 255<br />
Description Part No. Each (€)<br />
CryoFill System N5370540 13400<br />
Includes LN 2 Control Box and CryoFill Dewar Tank<br />
CryoFill Dewar Tank, 50 L N5373009 3290<br />
Long LN 2 Transfer Line, 2 m N5372187 988<br />
Short LN 2 Transfer Line, 1 m N5372060 529<br />
LN 2 Septum Assembly (LN 2 Receptacle) N5370147 28<br />
LN 2 Cold Finger Threaded Solid Aluminum Cylinder 04191577 312<br />
For use with ice water bath or LN 2 .<br />
DSC Supplies and Accessories Thermal Analysis<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
347
DSC Supplies and Accessories<br />
Intracoolers and Subambient Accessories<br />
Thermal Analysis DSC Supplies and Accessories<br />
Subambient Accessories for DSC 7<br />
Dry Box Assembly<br />
Includes all mounting hardware.<br />
Description Part No. Each (€)<br />
With Irises N5190226 1518<br />
With Gloves N5190738 1887<br />
Cold Water Turbulent Chamber Kit<br />
This kit can be used with a cold water faucet or water circulator<br />
if ice is not available for the reservoir. (Included with the<br />
Ambient DSC 7).<br />
Description Part No. Each (€)<br />
Diamond DSC N5370142 401<br />
DSC 7 04190367 740<br />
Dry Box Glove Kit<br />
Allows existing dry box to be<br />
converted from Irises to gloves.<br />
Service installation recommended.<br />
Dry Box Sample Entry Port<br />
For DSC 7 Dry Box Assembly w/gloves.<br />
Dry Box Hold Down Screw<br />
Replacement Iris<br />
Eight required.<br />
Replacement Gloves with Arms<br />
Size 9.<br />
LN 2 Cold Finger Threaded Solid Aluminum Cylinder<br />
For use with ice water bath or LN 2 .<br />
DSC 7 Gasket<br />
Red rubber gasket between<br />
sample holder and deck lid.<br />
Part No.<br />
Each (€)<br />
N5190504 759<br />
Part No.<br />
Each (€)<br />
N5190784 456<br />
Part No.<br />
Each (€)<br />
09907504 8<br />
Part No.<br />
Each (€)<br />
N5191009 8<br />
Part No.<br />
Each (€)<br />
03191024 236<br />
Part No.<br />
Each (€)<br />
04191577 312<br />
Part No.<br />
Each (€)<br />
N5191845 77<br />
Subambient Accessories for<br />
PYRIS 6 DSC/DSC 6<br />
PRYIS 6 DSC/DSC 6 Subambient Kit<br />
Description Part No. Each (€)<br />
With Dewar N5200032 7100<br />
Without Dewar N5200033 1441<br />
Subambient Accessories for Sapphire DSC<br />
Air Cooling Accessory and Gas Switching<br />
Accessory for Sapphire DSC<br />
3 Channels: one to cool down furnace and the other two<br />
for gas switch. Requires, but does not<br />
include, Cooling Jacket (N5351002). Part No. Each (€)<br />
Cooling Jacket Sapphire DSC<br />
Required for LN 2 Automatic Gas<br />
Cooling Accessory (N5350110) and<br />
Air Cooling Accessory (N5350302).<br />
LN 2 Auto Cooling Accessory<br />
Allows operation of the Sapphire DSC from -150° to 725 °C.<br />
Requires, but does not include,<br />
Cooling Jacket (N5351002). Service<br />
installation recommended.<br />
Part No.<br />
N5350110<br />
Each (€)<br />
10600<br />
Cooling Can Accessory, Sapphire DSC<br />
N5350302 2743<br />
Part No.<br />
Each (€)<br />
N5351002 3809<br />
Manual LN 2 cooling device. Sits on top of the instrument.<br />
Enables ability to speed up cooling<br />
time between measurements and<br />
to start at subambient temperatures.<br />
Part No.<br />
N5351009<br />
Each (€)<br />
854<br />
348
DSC Supplies and Accessories<br />
Photocalorimeter Accessories and Supplies<br />
The Photocalorimeter Accessory extends the use of the<br />
Diamond DSC and permits the quantitative measurement of the<br />
enthalpy changes (heat flow) in a material during and after<br />
exposure to UV light. This configuration provides the most<br />
advanced system for the study of photo initiated reactions.<br />
Typical applications include:<br />
Monitoring the curing process for light-activated<br />
curing of printing inks and coatings<br />
Determining the effects of UV light on polymers<br />
in accelerated testing<br />
For information about the PerkinElmer Photocalorimeter Accessory, please<br />
contact your local PerkinElmer Sales Representative.<br />
Aluminum Capsules<br />
Aluminum Sample Pans and Covers<br />
for UV Curing Studies<br />
In response to requests from our customers, PerkinElmer<br />
developed these pans to allow reproducible isolation of small<br />
quantities of liquid samples (such as uncured resins) so that<br />
UV curing reactions may be more accurately monitored by<br />
DSC. Pans are available alone or with quartz covers. We<br />
recommend you use quartz covers when analyzing samples<br />
which will evaporate at the temperature of interest.<br />
Product Quantity Part No. Each (€)<br />
Aluminum Sample Pans* pkg. 100 B0196858 379<br />
Aluminum Sample Pans* 100 of Each B0198030 1469<br />
and Quartz Covers<br />
* Volume of 12.5 microliters<br />
Photocalorimeter Accessory<br />
Kit for Diamond DSC<br />
Photocalorimeter Accessory Kit<br />
The photocalorimeter accessory extends the use of the<br />
Diamond DSC and permits to quantitatively measure the<br />
enthalpy changes (heat flow) in a material during and after<br />
exposure to UV light. This configuration provides the most<br />
advanced system for the study of photo initiated reactions.<br />
Requires Service Engineer installation.<br />
Features:<br />
Short calorimetric response time of the DSC permits the<br />
analysis of even the most rapid curing reactions<br />
Precise isothermal temperature control of the power<br />
compensation Diamond DSC, even during the most rapid<br />
reaction, guarantees the accuracy of measurements<br />
Photofeedback system maintains constant lamp intensity,<br />
thus assuring accurate and consistent sample exposure<br />
Exposure intensity directly measured in the DSC analyzer<br />
Part No.<br />
Each (€)<br />
N5360016 23300<br />
Photocalorimeter Accessory<br />
Replacement Parts<br />
Quartz Window for Sample<br />
Cup Holder for Diamond DSC<br />
Graphite Disc<br />
Set of 2.<br />
Replacement Quartz Windows<br />
for DSC 7 Sample Holder Cover<br />
Two windows are required<br />
for each sample holder.<br />
Sample Holder Cover Without<br />
Quartz Window for DSC 7<br />
Part No. Each (€)<br />
N5365044 34<br />
Part No. Each (€)<br />
B0186924 31<br />
Part No. Each (€)<br />
B0066549 21<br />
Part No. Each (€)<br />
B0181576 718<br />
DSC Supplies and Accessories Thermal Analysis<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
349
DSC Supplies and Accessories<br />
Sample Holder Supplies and Calibration Reference Materials<br />
Thermal Analysis DSC Supplies and Accessories<br />
PYRIS 1 DSC Flow-Through Cover Kit Part No. N5370153<br />
DSC 7 Flow-Through Cover Kit Part No. 03190062<br />
O-Ring for Chimney Part No. 09902102<br />
DSC Calibration Reference Materials<br />
PerkinElmer reference materials are 99.999% pure. DSC<br />
requires elements of this purity so that the instrument can<br />
be accurately calibrated. Depend on PerkinElmer for quality<br />
calibration reference materials.<br />
Reference<br />
Transition<br />
Material Point Part No. Each (€)<br />
Indium 156.60 °C 03190033 29<br />
Tin 231.88 °C 03190034 75<br />
Lead 327.47 °C 03190035 43<br />
Zinc 419.47 °C 03190036 38<br />
Encapsulated Kit 02190045* 305<br />
for DSC 7, PYRIS 1 DSC, and Diamond DSC<br />
N5190762** 79<br />
* Includes a large and small indium, tin, and lead<br />
** Includes indium and zinc<br />
Specific Heat Kit<br />
Includes four sapphire disks manufactured to two separate<br />
diameters and thicknesses. Also includes a calibration chart<br />
giving the specific heat of aluminum<br />
oxide in the form of synthetic sapphire. Part No. Each (€)<br />
DSC Flow-Through Cover Kits<br />
DSC Flow-Through Cover Kits<br />
02190136 494<br />
The flow-through cover provides a short path for volatiles or<br />
decomposition products to exit from the DSC sample holder.<br />
When the flow-through cover is installed, the sliding sample<br />
holder enclosure cover is displaced by the accessory. The<br />
flow-through cover should be used with samples that undergo<br />
decomposition, dehydration, or oxidation, especially if<br />
the thermal conductivity of the products of the reaction<br />
is different from that of the purge gas.<br />
Description Part No. Each (€)<br />
Diamond DSC N5360142 1714<br />
PYRIS 1 DSC N5370153 1581<br />
DSC 7, DSC 4 03190062 1734<br />
O-Ring for Chimney<br />
Small, two required.<br />
O-Ring for DSC 7 Flow-Through Cover<br />
Large, two required.<br />
Part No.<br />
Each (€)<br />
09902102 1<br />
Part No.<br />
Each (€)<br />
09902205 4<br />
350
DSC Supplies and Accessories<br />
Sample Holder Supplies and Calibration Reference Materials<br />
Sample Holder Supplies<br />
Sample Holder Cover Reforming Tool<br />
DSC performance is enhanced with sample holder covers<br />
that are formed properly and not degraded by extended<br />
usage. This tool allows the analyst<br />
to reform the platinum covers to<br />
their original dimensions.<br />
Part No.<br />
03190030<br />
Each (€)<br />
837<br />
Vented Platinum Sample Holder Covers<br />
Each cover has two vent holes and is used for the Diamond<br />
DSC, PYRIS 1 DSC, and DSC 7 sample holders.<br />
Description Part No. Each (€)<br />
Kit of 2 04190299 214<br />
Kit of 6 03190031 563<br />
Forceps<br />
Sample Holder<br />
Cover Reforming Tool<br />
Part No. 03190030<br />
Hook Forceps<br />
Part No. 09908138<br />
Vented Platinum<br />
Sample Holder Cover<br />
Part No. 04190299<br />
Description Part No. Each (€)<br />
Flat Round Tips 09908400 60<br />
Flat Pointed Tips N5361078 183<br />
Hook 09908138 66<br />
Guard Ring Inserts<br />
A pair of removable, shaped aluminum inserts fitting in DSC<br />
sample holder cavities, preventing inadvertent dropping of<br />
pans, covers, etc., into the cavity. Also recommended for<br />
applications generating condensable gaseous products as<br />
the inserts are readily removed for cleaning.<br />
Description Part No. Each (€)<br />
DSC 7, DSC 4 (pair) 03190236 134<br />
PYRIS 1 DSC (pair) N5370236 408<br />
Diamond DSC (pair) N5360236 105<br />
DSC 7 Guard Ring Plastic Collar<br />
O-Ring for Swing-Away Cover<br />
For standard swing-away cover on<br />
DSC 7 and DSC 4.<br />
Diamond DSC Loading Tool<br />
Gasket for DSC 7 Draft Shield<br />
DSC 7 Gasket<br />
Guard Ring Inserts (pair)<br />
for PYRIS 1 DSC<br />
Part No. N5373126<br />
Red rubber gasket between<br />
sample holder and deck lid.<br />
Guard Ring Inserts (pair)<br />
for DSC 7, DSC 4<br />
Part No. 03190236<br />
Part No.<br />
Allows an easy insertion and<br />
removal of sample or reference<br />
pans or platinum covers.<br />
Part No.<br />
Each (€)<br />
N5361180 39<br />
Part No.<br />
Each (€)<br />
N5191085 42<br />
Part No.<br />
Each (€)<br />
N5191333 110<br />
Part No.<br />
Each (€)<br />
09902206 22<br />
Each (€)<br />
N5191845 77<br />
DSC Supplies and Accessories Thermal Analysis<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
351
DSC Supplies and Accessories<br />
Structure of Common Polymer Poster<br />
Thermal Analysis DSC Supplies and Accessories<br />
Melting Point (MP) and Glass Transition Temperature (Tg) are the most important thermodynamic<br />
parameters for the common polymers. These properties can be easily and quickly determined by DSC.<br />
Melting point temperature range (°C)<br />
Glass transition temperature range (°C)<br />
352
DTA Supplies and Accessories<br />
DTA Calibration Reference Materials and Supplies<br />
DTA 7 and DTA 1700 Supplies<br />
and Accessories<br />
Components Part No. Each (€)<br />
1 DTA Alumina Purge Gas Tube 04190119 204<br />
Located between the sample and<br />
reference cups; permits purging<br />
of the sample area (pkg. 2)<br />
2 Sample and Reference Cup Holders 04190163 1257<br />
95% platinum/5% rhodium cups<br />
0.47 cm diameter (pkg. 4)<br />
Aluminum Oxide Powder* 04190197 49<br />
Vial of 28 g<br />
4 Thermocouple Retaining Clips 04190117 56<br />
(pkg. 6)<br />
5 Thermocouple Support Post 04191228 408<br />
* Operating Tip: Place some aluminum oxide powder between<br />
the sample and the cup to prevent the sample from adhering<br />
to the cup.<br />
7 Sample and Reference Cups<br />
Alumina, platinum, and magnesia cups are available.<br />
Use alumina cups if the sample is to be brought to<br />
temperatures higher than 1500 °C and when metal<br />
samples are being run. Use magnesia cups for super<br />
conductor investigations. Use the platinum cups when<br />
alumina and magnesia cups are not suitable.<br />
Cup Material Size Quantity Part No. Each (€)<br />
Alumina 60 mm 3 1 04191290 34<br />
60 mm 3 6 04190166 192<br />
60 mm 3 25 04190387 883<br />
100 mm 3 1 04191291 111<br />
100 mm 3 6 04190217 643<br />
100 mm 3 25 04190388 1043<br />
Alumina Sample Pair N5380063 90<br />
Cup Lids<br />
Platinum 100 mm 3 10 04190165 1144<br />
Magnesia 60 mm 3 1 04191838 55<br />
100 mm 3 1 04191839 62<br />
Operating Tip: Since some samples will adhere to the cups,<br />
we recommend that you keep spare cups on hand.<br />
Components Part No. Each (€)<br />
9 Non-magnetic Straight Forceps 09908400 60<br />
DTA 7 Only Supplies and Accessories<br />
Components Part No. Each (€)<br />
3 Matched Sample and Reference N5380052 580<br />
Thermocouples*, matched pair, S-type<br />
O-Rings 09921019 2<br />
Furnace tube<br />
Base 09921018 3<br />
Purge tube 09902245 2<br />
Components Part No. Each (€)<br />
8 Alumina Furnace Tube N5380037 644<br />
Cylindrical with closed end. Placed<br />
over the cups to ensure even heating<br />
of both the sample and reference<br />
materials and to provide a controlled<br />
gas environment<br />
Oven Thermocouple Assembly, S-type N5380051 434<br />
Sapphire Cup for Oven Thermocouple N5191875 579<br />
Replacement Furnace Heater Assembly N5380053 7100<br />
DTA 7 Spares Kit N5380015 2765<br />
Hex Wrench 09907236 1<br />
Open Alumina Furnace Tube Kit N5380062 4285<br />
For collecting evolved gases<br />
generated during a DTA experiment<br />
Balance Cup Stand N5381081 29<br />
Use this stand to support the sample<br />
cup vertically while weighing your sample<br />
* Operating Tip: When replacing the thermocouple, replace<br />
both thermocouples because they are a matched pair.<br />
DTA Calibration Reference Materials<br />
Reference Material Transition Point Part No. Each (€)<br />
Aluminum 660.10 °C N5380057 18<br />
Gold 1063.00 °C N5380058 90<br />
Palladium 1551.85 °C N5380071 29<br />
7<br />
2<br />
9<br />
1<br />
4<br />
DTA 7<br />
5<br />
8<br />
7<br />
3<br />
6<br />
DTA Supplies and Accessories Thermal Analysis<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
353
Thermal Analysis Laboratory Products and Accessories<br />
Laboratory Products and Accessories<br />
Purge Gas Accessories<br />
Fittings<br />
(Included<br />
with Filter<br />
Dryer Kit)<br />
1 Filter Dryer Kit<br />
2<br />
Filters and Traps<br />
Filter Dryer<br />
Replacement<br />
Cartridge<br />
Filters<br />
1<br />
2<br />
3<br />
Filter Traps<br />
Copper Tubing<br />
Teflon<br />
Tubing<br />
NPT Connector (male)<br />
NPT Reducing<br />
Bushing (female)<br />
Filter Dryer Kit Part No. N5370103<br />
Components Part No. Each (€)<br />
Filter Dryer Kit N5370103 319<br />
Removes moisture and particulates<br />
from your purge gas<br />
Includes all the necessary fittings needed<br />
to make pneumatic connections easy<br />
Tape and tubing are not included,<br />
Filter Dryer Replacement Cartridge 09923454 46<br />
with a visual indicator for Hammond Dryer<br />
Type “H” Purge Gas Restrictor 01541498 93<br />
Provides a flow of about 1 cc/min. purge per pound of<br />
pressure for nitrogen, air, or oxygen. (For helium, the<br />
flow rate is substantially faster)<br />
Thread Sealant Tape 09908134 19<br />
Roll of Teflon tape, 1/4 in. x 260 in.<br />
The In-line Filter Trap removes moisture, oil, and dust from<br />
the gases before they flow into your instrument. It consists<br />
of a transparent acrylic tube containing a molecular sieve<br />
and a desiccant, Drierite. An indicator changes color to let<br />
you know when the packing must be changed, while the<br />
cartridge design makes replacement of the filter material<br />
easy. A refill kit is also available.<br />
In-line Filter Trap Part No. N9301178<br />
Description Part No. Each (€)<br />
Copper Gas Line Kit N2410170 217<br />
In-Line Filter Trap N9301178 200<br />
Refill Kit for the In-Line Filter Trap N9301176 29<br />
Flow Meters<br />
Allows you to accurately control and conserve purge gas<br />
Measures nitrogen flow from 0 to 100 cc/min.<br />
Includes 1/8 NPT female connections<br />
Diamond DMA Flow Meters<br />
Description Part No. Each (€)<br />
Flow Meter 20-140 mL/min. N5356000 1051<br />
Flow Meter 50-500 mL/min. N5356001 1051<br />
Float Displacement<br />
Flow Meter<br />
Gas Cylinder<br />
Installation Accessories<br />
Adjustable Wrench for Cylinder Pressure Regulators<br />
Adjustable 30 cm steel wrench<br />
opens out to 4.5 cm; fits all the<br />
regulators listed on this page.<br />
Gas Cylinder Safety Holders<br />
Keep your lab safe from toppled gas cylinders! Safety<br />
holders are designed for either wall mount or bench<br />
mount. Body of cast aluminum. Adjustable nylon web<br />
strap holds cylinders.<br />
Product Part No. Each (€)<br />
Wall Mount N9301298 101<br />
Bench Mount N9301299 101<br />
Gas Split Kit<br />
Allows for simple expansion of a limited supply of gas<br />
sources. A single resource can be split into individual<br />
regulated <strong>supplies</strong>. Maximum inlet<br />
pressure of 300 psi. Maximum outlet<br />
pressure or 150 psi.<br />
Part No.<br />
N5190462<br />
Each (€)<br />
166<br />
Gas Regulators and Accessories<br />
Oxygen Pressure Regulator<br />
Part No.<br />
Each (€)<br />
02901624 300<br />
Float Displacement Flow Meter<br />
Part No. 02901624<br />
Part No.<br />
Each (€)<br />
N9301324 55<br />
Guarantees constant delivery pressure even when cylinder<br />
pressure varies. Two-stage regulator with brass body and<br />
stainless steel diaphragm. Maximum inlet pressure of<br />
20,700 KPa. Supplied with CGA-540 adapter. Includes a<br />
Swagelok 1/4 in. NPT to 1/8 in. fitting, which is used to<br />
attach the regulator to the purge gas<br />
tubing. Approximate weight: 1.3 Kg. Part No. Each (€)<br />
02400084 606<br />
354
Helium/Nitrogen Pressure Regulator<br />
Two-stage regulator for precise outlet pressure control.<br />
Brass body and stainless steel diaphragm for long life<br />
and minimum maintenance. Maximum inlet pressure of<br />
20,700 KPa. Supplied with CGA-580<br />
adapter. Approximate weight: 1.3 Kg. Part No. Each<br />
Gas Pressure Regulator Features:<br />
Barstock Body Construction<br />
Barstock bodies have a lower internal volume than forged<br />
bodies, allowing for more complete purging of atmospheric<br />
contaminant's.<br />
Stainless Steel Diaphragms<br />
Unlike elastomeric diaphragms, stainless steel diaphragms<br />
don’t absorb atmospheric contaminant's or allow them to<br />
diffuse into the gas stream.<br />
Metal-to-Metal Seals<br />
Metal-to-metal seals provide reliable protection from<br />
inboard leakage of atmospheric contaminant's.<br />
Swagelok Reducing Fittings<br />
Size Part No. Each (€)<br />
1/4-1/8 in. 09903471 12<br />
1/4-1/4 in. 09903196 10<br />
Copper Line Assembly, 6 foot<br />
Includes 1/8 in. Swagelok<br />
fitting at each end.<br />
Gas Line Assembly, Plastic<br />
Type “H” Purge Gas Restrictor<br />
Provides a flow of about 1 cc/min.<br />
purge per pound of pressure for<br />
nitrogen, air, or oxygen. (For helium,<br />
the flow rate is substantially faster).<br />
Thread Sealant Tape<br />
Roll of Teflon tape, 1/4 x 260 in.<br />
Gas Selector Accessory<br />
The GSA 7 Gas Selector Accessory enables reproducible<br />
rapid sample atmosphere switching. With this gas selector,<br />
thermal experiments are totally automated, requiring no<br />
operator intervention during even the most complex<br />
analyses. Can be used with Diamond DSC, PYRIS 1 DSC,<br />
DSC 7, PYRIS 1 TGA, and TGA 7.<br />
Product Voltage Part No. Each (€)<br />
GSA 7 Gas Selector Accessory 100 V N5190269 2771<br />
115 V N5190270 2771<br />
230 V N5190271 2771<br />
3<br />
Laboratory Products and Accessories<br />
02400085 606<br />
Part No.<br />
Each (€)<br />
02400011 85<br />
Part No.<br />
Each (€)<br />
N2410147 79<br />
Type “H”<br />
Restrictor<br />
Part No.<br />
Each (€)<br />
01541498 93<br />
Part No.<br />
(€)<br />
Each (€)<br />
09908134 19<br />
Purge Gas Accessories<br />
Diamond Air Cooling and Gas Switching Accessory<br />
For Diamond TG/DTA, Diamond TMA,<br />
and Diamond DMA. 3 channels: One<br />
for cooling down the furnace and<br />
2 for purge gas switching.<br />
Gas Station for Thermal Analysis<br />
Use the Thermal Analysis Gas<br />
Station (TAGS), a gas selector<br />
accessory with all thermal<br />
analyzers. The TAGS is a very<br />
flexible accessory featuring full<br />
control of all gases used in<br />
thermal analysis. In addition<br />
to performing gas switching,<br />
the TAGS also fully controls<br />
the gas flow rate, independent<br />
of the type of gas, and detects<br />
rapid changes in pressure and<br />
empty cylinders.<br />
Part No.<br />
Each (€)<br />
N5350202 2532<br />
TAGS Uses Calibrated Massflow Controls<br />
Massflow controllers provide more accurate control of flow<br />
rates than pressure controls, consequently reproducibility<br />
of results (when studying effect of flow rate on material<br />
properties) is improved. Massflow controls measure and<br />
controls the flow of gases independent of changes in<br />
pressure and temperature.<br />
TAGS is Simple to Program<br />
With the PYRIS Series software, TAGS is fully computercontrolled<br />
utilizing up to four different gases. Gas switching<br />
can be done on a time or temperature program.<br />
With the 7 Series/Unix software, TAGS can operate by<br />
monitoring the instrument furnace temperature and can<br />
switch between any of four gases at a programmed<br />
temperature or programmed time. Multiple gas switching<br />
methods can be developed and stored in TAGS memory.<br />
GSA 7 Gas Selector<br />
Part No. N5190270<br />
Thermal Analysis Gas Station (TAGS)<br />
Part No.<br />
Each (€)<br />
N5202019 5400<br />
Laboratory Products and Accessories Thermal Analysis<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
355
Mechanical Analysis (DMA)<br />
3-Point Bending Measuring Systems<br />
Thermal Analysis Mechanical Analysis (DMA)<br />
The bending measuring systems available from PerkinElmer<br />
are used to perform many of the classical mechanical testing<br />
applications. 3-Point bending is typically used with high<br />
modulus materials such as thermoplastics, resins, epoxy<br />
and graphite laminates, composites, and highly crystalline<br />
thermoplastics through Tg. Sample geometries include solid<br />
materials, such as bar stock, test plaques, test coupons,<br />
sheet stock, wire, rods, and tubes.<br />
Diamond DMA Bending<br />
Measuring System<br />
3-Point Bending<br />
3-Point Bending<br />
Measuring System*<br />
Part No.<br />
* More Bending Systems in Dual Cantilever Section<br />
DMA 7/DMA 7e 3-Point Bending<br />
System Replacement Parts<br />
Each (€)<br />
N5353035 2381<br />
Components Part No. Each (€)<br />
1 Universal DMA Sample Tube N5390107 714<br />
For use with stainless steel 3-Point Bending, Extension, and<br />
Parallel Plate measuring systems<br />
2 Universal DMA Probe Tip Holder N5390105 344<br />
For use with stainless steel 3-Point Bending, 2-Point, 3-Point/<br />
4-Point Bending, Single and Dual Cantilever, and Parallel Plate<br />
measuring systems. Includes Probe Tip Holder (N5390104),<br />
Collet (N5391004), and Lock Nut (N5391003)<br />
3 Knife Edge Bending Platform 5 mm N5390102 198<br />
10 mm N5390197 198<br />
4<br />
15 mm N5390101 198<br />
5<br />
20 mm N5390122 198<br />
6 Knife Edge Probe Tip 10 mm N5391016 91<br />
7<br />
5 mm N5391063 91<br />
8<br />
(sphere) 3 mm N5391017 40<br />
9 Hex Nut 09911186 1<br />
1<br />
6<br />
7 8<br />
2<br />
3 4 5<br />
9<br />
DMA 7/DMA 7e Large Adjustable<br />
3-Point/4-Point Bending Kit<br />
This kit provides for the analysis of extremely high modulus<br />
samples and larger samples. Standard test bars, i.e., dog<br />
bones, test plaque, and other samples up to 165 mm long<br />
can be tested with this kit. This kit<br />
complies with ASTM Standard D790.<br />
Kit includes:<br />
Part No.<br />
N5390478<br />
Each (€)<br />
4886<br />
Product Part No. Each (€)<br />
Large Platform N5390420 1862<br />
10 mm 4-Point Bending Probe Tip N5390453 459<br />
15 mm 4-Point Bending Probe Tip N5390452 459<br />
20 mm 4-Point Bending Probe Tip N5390451 459<br />
10 mm Knife 3-Point Bending Probe Tip N5391016 91<br />
3 mm Spherical Probe Tip N5391017 40<br />
Universal DMA Probe Tip Holder N5390105 344<br />
Split Ferrule N5191662 91<br />
Collar N5391054 91<br />
DMA 7/DMA 7e Measuring<br />
Parts for ASTM 5934-96<br />
Cylindrical Probe Tip<br />
Rounded 3-Point Bending Platforms<br />
Part No.<br />
Each (€)<br />
N5390175 281<br />
These platforms are designed<br />
to address several ASTM test<br />
procedures which require rounded<br />
rather than knife-edge surfaces on<br />
bending platforms.<br />
Width Part No. Each (€)<br />
5 mm N5390428 198<br />
15 mm N5390427 198<br />
20 mm N5390426 198<br />
356
Mechanical Analysis (DMA)<br />
3-Point Bending Measuring Systems<br />
DMA 7/DMA 7e Quartz 3-Point<br />
Bending Measuring Systems<br />
and Replacement Parts<br />
DMA Quartz 3-Point Bending Systems<br />
Similar to the stainless steel 3-Point measuring system but<br />
of quartz construction. Measuring systems are shipped in an<br />
attractive wooden case and include 1 mm hemispherical tip<br />
probe, 3 mm knife probe, 5 mm knife probe, mounting<br />
hardware, spare shims, and instructions.<br />
Description Part No. Each (€)<br />
For use with the Standard Furnace N5390136 2627<br />
For use with the High-Temperature Furnace N5390137 2627<br />
DMA 7/DMA 7e 3-Point Bending<br />
Probe Alignment Tools<br />
For Knife-edge Spacing.<br />
Size Part No. Each (€)<br />
5 mm N5391095 48<br />
10 mm N5391183 255<br />
15 mm N5391094 119<br />
20 mm N5391093 60<br />
Quartz 3-Point Bending Sample Tubes<br />
Components Part No. Each (€)<br />
10 10 Used with Standard Furnace, N5191472 714<br />
11<br />
part of N5390136 kit<br />
Used with High-Temperature Furnace, N5191549 555<br />
part of N5390137 kit<br />
12 12 Bending Platform N5391181 644<br />
Quartz Probes<br />
Quartz 10 mm 3-Point bending platform is permanently<br />
fused to the base of the sample tube. Used with the<br />
High-Temperature Furnace (Not shown.)<br />
Part of Quartz 3-Point Bending Systems<br />
(N5390137 and N5390136).<br />
Components Part No. Each (€)<br />
13 13 1 mm Round Tip Probe N5190377 504<br />
(Hemispherical, 0.02 in.)<br />
14 14 3 mm Knife-Edge Probe N5190393 619<br />
15 15 7 mm Knife-Edge Probe N5190614 542<br />
High-Temperature Tape 02507907 56<br />
For securing thermocouple to the sample tube<br />
Quartz Measuring System<br />
for Standard Furnace<br />
Part No. N5390136<br />
11<br />
12<br />
Quartz 3-Point<br />
Bending Sample Tubes<br />
Stainless Steel<br />
Measuring System<br />
Part No. N5390137<br />
10<br />
13 14 15<br />
Quartz Probes<br />
Mechanical Analysis (DMA) Thermal Analysis<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
357
Mechanical Analysis (DMA)<br />
Bending/Dual Cantilever Measuring Systems<br />
Thermal Analysis Mechanical Analysis (DMA)<br />
4<br />
1<br />
Bending<br />
3<br />
2<br />
The Dual Cantilever measuring system is used to perform<br />
many of the classical mechanical testing applications.<br />
It is typically used with medium-modulus materials<br />
such as elastomers and materials above their glass<br />
transition temperature.<br />
Low-mass clamping system allows optimum temperature<br />
accuracy, faster scanning rates, faster temperature<br />
equilibrium, and cool-down<br />
Vertical mounting ensures that forces are collinear<br />
Since no static force is required, analysis can continue even<br />
as sample melts<br />
Measuring system can easily be modified to perform single<br />
cantilever analyses<br />
Diamond DMA Bending Measuring System/<br />
(Dual Cantilever)<br />
Description Part No. Each (€)<br />
8 mm N5353083 1428<br />
20 mm N5353081 2477<br />
32 mm N5353082 1714<br />
Chuck and Clamp 20 mm for Bending N5353084 1094<br />
Plate, Gap Setting in Bending N5353079 451<br />
Torque Wrench Set N5353087 620<br />
DMA 7/DMA 7e Dual Cantilever Measuring<br />
System and Replacement Parts<br />
Dual Cantilever Measuring System<br />
Used to analyze materials with mid-range modulus. Two<br />
different measuring systems are supplied: a high-modulus<br />
system which is recommended when the storage modulus<br />
is greater than 1 x 108, and a low-modulus system which<br />
is recommended when the storage modulus is less than<br />
1 x 108. Measuring system is shipped in an attractive<br />
wooden case and includes high-modulus and low-modulus<br />
sample tubes, a universal probe tip holder, a dual cantilever<br />
probe tip, a center clamp assembly,<br />
a hex ball driver, and instructions. Part No. Each (€)<br />
Components Part No. Each (€)<br />
1 Dual Cantilever Sample Tube N5390176 803<br />
Includes side clamp fixture assembly, high-modulus type<br />
2 Universal DMA 7/DMA 7e N5390105 344<br />
Probe Tip Holder<br />
For use with the stainless steel Single and Dual Cantilever,<br />
2-, 3-, and 4-Point Bending, and Parallel Plate measuring<br />
systems, includes Probe Tip Holder (N5390104), Collet<br />
(N5391004), and Lock Nut (N5391003)<br />
3 Center Clamp Assembly N5390175 281<br />
Used on low-modulus and high-modulus sample tube<br />
4 Dual Cantilever Sample Tube N5390174 1065<br />
Includes side clamp fixture assembly, low-modulus type<br />
High-Temperature Tape 02507907 56<br />
For securing thermocouple to the sample tube<br />
N5390131 3233<br />
358
Mechanical Analysis (DMA)<br />
Compression/Expansion Measuring Systems<br />
Diamond DMA Measuring<br />
System and Parts<br />
DMA 7/DMA 7e Parallel<br />
Plates with Tray Kits<br />
Compression Measuring System<br />
The compression head uses the<br />
components of the tension head.<br />
There is one size for the compression<br />
head containing one top plate and<br />
one bottom plate.<br />
Torque Wrench Set<br />
DMA 7/DMA 7e<br />
Cup and Plate Kits<br />
Compression<br />
Part No.<br />
Each (€)<br />
N5353032 291<br />
Part No.<br />
Each (€)<br />
N5353087 620<br />
These kits include 5, 10, 15, and 20 mm diameter plates<br />
and 8, 13, 18, and 21.5 mm cups. They can be used to study<br />
low-modulus materials that have honey-like consistencies,<br />
or to study thermoplastics and rubbers which are above<br />
their Tg’s, or study samples that cure or melt, to or from,<br />
the liquid state.<br />
Product Part No. Each (€)<br />
Cup and Plate Trial Kit N5390464 261<br />
Includes:<br />
8 mm Cup and 5 mm Plate; 13 mm Cup and 10 mm Plate;<br />
18 mm Cup and 15 mm Plate; 21.5 mm Cup and 20 mm Plate;<br />
Instruction Sheet<br />
5 mm Cup and Plate Kit (10 of each) N5390465 434<br />
Includes:<br />
8 mm Cup and 5 mm Plate<br />
10 mm Cup and Plate Kit (10 of each) N5390466 675<br />
Includes:<br />
13 mm Cup and 10 mm Plate<br />
15 mm Cup and Plate Kit (10 of each) N5390467 510<br />
Includes:<br />
18 mm Cup and 15 mm Plate<br />
20 mm Cup and Plate Kit (10 of each) N5390468 542<br />
Includes:<br />
21.5 mm Cup and 20 mm Plate<br />
These kits include plates with diameters of 5, 10, and 15 mm.<br />
They can be used with materials that become so fluid they<br />
flow out of the parallel plates. In this event, the bottom<br />
tray will act as a catch basin and prevent the liquid from<br />
flowing into the furnace. Use these kits for the study of<br />
thermoplastics and rubbers which are above their Tg’s.<br />
Product Part No. Each (€)<br />
Parallel Plates with Tray Trial Kit N5390469 300<br />
Includes (Bottom/Top):<br />
5 mm Parallel Plate with Tray/5 mm Plate<br />
10 mm Parallel Plate with Tray/10 mm Plate<br />
15 mm Parallel Plate with Tray/15 mm Plate<br />
Instruction Sheet<br />
5 mm Parallel Plate with Tray Kit N5390470 87<br />
Includes (Bottom/Top):<br />
5 mm Parallel Plate with Tray/5 mm Plate<br />
10 mm Parallel Plate with Tray Kit N5390471 94<br />
Includes (Bottom/Top):<br />
10 mm Parallel Plate with Tray/10 mm Plate<br />
15 mm Parallel Plate with Tray Kit N5390472 102<br />
Includes (Bottom/Top):<br />
15 mm Parallel Plate with Tray/15 mm Plate<br />
DMA 7/DMA 7e Cup and Plate Kits<br />
Part No. N5390466<br />
Sample<br />
Tray<br />
Top Plate<br />
DMA 7/DMA 7e Parallel Plates with Tray Kits<br />
Part No. N5390472<br />
Plate<br />
Cup<br />
Mechanical Analysis (DMA) Thermal Analysis<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
359
Mechanical Analysis (DMA)<br />
Compression/Expansion Measuring Systems<br />
Thermal Analysis Mechanical Analysis (DMA)<br />
2<br />
1<br />
5 6 7 8<br />
4 3<br />
9<br />
Stainless Steel Parallel Plate Measuring System Part No. N5390133<br />
DMA 7/DMA 7e Parallel<br />
Plate Measuring System<br />
and Replacement Parts<br />
Stainless Steel Parallel Plate Measuring System<br />
Measuring system is shipped in an attractive wooden case<br />
and includes 1, 3, 5, 10, and 20 mm parallel plates, mounting<br />
hardware, and instructions.<br />
Part No. Each (€)<br />
N5390133 2306<br />
Components Part No. Each (€)<br />
1 Universal DMA Sample Tube N5390107 714<br />
For use with Stainless Steel Parallel Plate, 3-Point Bending,<br />
and Extension measuring systems.<br />
2 Universal DMA Probe Tip Holder N5390105 344<br />
For use with Stainless Steel Parallel Plate, 2-, 3-, and 4-Point<br />
Bending. Single and Dual Cantilever measuring systems.<br />
Includes Probe Tip Holder (N5390104), Collet (N5391004),<br />
and Lock Nut (N5391005)<br />
Stainless Steel Parallel Plate Probe Tips<br />
3 Top only, 1 mm* N5391014 40<br />
4 Top only, 3 mm* N5391015 40<br />
5 Top and bottom, 5 mm* N5390143 126<br />
6 Top and bottom, 10 mm* N5390144 126<br />
7 Top and bottom, 15 mm* N5390145 126<br />
8 Top and bottom, 20 mm* N5390146 126<br />
9 Hex Nut 09911186 1<br />
High-Temperature Tape 02507907 56<br />
For securing thermocouple to the sample tube<br />
* Each stainless steel replacement parallel plate set includes<br />
the hex nut used to fasten the bottom plate to the probe<br />
tip holder.<br />
360
Mechanical Analysis (DMA)<br />
Compression/Expansion Measuring Systems<br />
DMA 7/DMA 7e Quartz Parallel<br />
Plate Measuring Systems<br />
and Replacement Parts<br />
Quartz Parallel Plate Systems<br />
Similar to the Stainless Steel Parallel Plate measuring system<br />
but of quartz construction. Measuring systems are shipped<br />
in an attractive wooden case and include 1, 3, and 6 mm<br />
parallel plate probes, mounting hardware, and instructions.<br />
Description Part No. Each (€)<br />
For use with the Standard Furnace N5390135 2627<br />
For use with the High-Temperature Furnace N5390138 2627<br />
Quartz Sample Tubes<br />
9<br />
10<br />
Description Part No. Each (€)<br />
Used with Standard Furnace, N5191837 676<br />
part of N5390135 kit<br />
Used with High-Temperature Furnace, N5191549 555<br />
part of N5390138 kit<br />
Quartz Parallel Plate Probes<br />
The following Quartz Probes are used on the Large<br />
and Small Quartz Parallel Plate measuring systems.<br />
11<br />
12<br />
13<br />
Description Part No. Each (€)<br />
1 mm N5190376 504<br />
3 mm N5190378 504<br />
6 mm N5190606 370<br />
DMA 7/DMA 7e Sintered<br />
Parallel Plate Kits<br />
These kits include 10, 15, and 20 mm diameter stainless<br />
steel plates. They can be used for materials with oil<br />
additives or solvents that otherwise slip between<br />
conventional parallel plates. Typical applications are<br />
rubbers, foods, lubricated polymers, and hydrogels.<br />
Product Part No. Each (€)<br />
Sintered Parallel Plates Trial Kit N5390460 363<br />
Includes (Bottom/Top):<br />
10 mm Sintered Parallel Plate/10 mm Sintered Parallel Plate<br />
15 mm Sintered Parallel Plate/15 mm Sintered Parallel Plate<br />
20 mm Sintered Parallel Plate/20 mm Sintered Parallel Plate<br />
Instruction Sheet<br />
10 mm Sintered Parallel Plates Kit (5 of each) N5390461 510<br />
Includes (Bottom/Top):<br />
10 mm Sintered Parallel Plate/10 mm Sintered Parallel Plate<br />
15 mm Sintered Parallel Plates Kit (5 of each) N5390462 510<br />
Includes (Bottom/Top):<br />
15 mm Sintered Parallel Plate/15 mm Sintered Parallel Plate<br />
20 mm Sintered Parallel Plates Kit (5 of each) N5390463 510<br />
Includes (Bottom/Top):<br />
20 mm Sintered Parallel Plate/20 mm Sintered Parallel Plate<br />
10<br />
Sample<br />
DMA 7/DMA 7e Sintered Parallel Plate Kits<br />
Part No. N5390460<br />
9<br />
Top Plate<br />
Bottom Plate<br />
Quartz Large and<br />
Small Parallel Plate<br />
Measuring Systems<br />
11 12 13<br />
Quartz Parallel Plate Measuring<br />
System for Standard Furnace<br />
Part No. N5390135<br />
Mechanical Analysis (DMA) Thermal Analysis<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
361
Mechanical Analysis (DMA)<br />
Extension and Shear Analysis Measuring Systems<br />
Thermal Analysis Mechanical Analysis (DMA)<br />
Diamond DMA Extension<br />
Measuring System and<br />
Replacement Parts<br />
The extension analysis measuring systems are used to<br />
measure materials such as thin films, textiles, and<br />
other fibers.<br />
Features:<br />
Fine resolution of force allows use of precise<br />
stresses and strains<br />
Wide bandwidth transducers and automatic sample<br />
corrections allow analysis of samples that experience<br />
massive expansion or shrinkage<br />
Blown Films:<br />
Determination of tensile properties<br />
Detection of orientation effects<br />
Detection of partial melting or recrystallization<br />
Analysis of heat-shrink materials<br />
Detection of oxidation, biodegradation, or aging<br />
Fibers, Yarns, and Monofilaments:<br />
Determination of tensile properties<br />
Analysis of single filaments, high- or low-denier fibers<br />
Determination of yarn heat-set points<br />
Extension Measuring System<br />
Part No. N5390132<br />
Tension<br />
Part No. N5353080<br />
Diamond DMA Extension Measuring System<br />
Part No.<br />
Each (€)<br />
N5353080 1808<br />
Description Part No. Each (€)<br />
Chuck Set-Probe Side for Tension N5353086 857<br />
Clamp Set-Base Side for Tension N5353085 906<br />
Plate, Gap Setting in Tension N5353078 309<br />
Torque Wrench Set N5353087 620<br />
DMA 7/DMA 7e Extension<br />
Measuring System and<br />
Replacement Parts<br />
DMA 7/DMA 7e Stainless Steel<br />
Extension Measuring System<br />
Used to study materials such as thin films and fibers.<br />
Includes a fixture which provides flat parallel clamping<br />
surfaces for analyzing materials such as films, and a fixture<br />
which provides tangential clamping surfaces for analyzing<br />
materials such as fibers or wire. Measuring system is shipped<br />
in an attractive wooden case and also includes an extension<br />
probe tip holder, mounting hardware,<br />
a hex ball driver, and instructions. Part No. Each (€)<br />
Used on standard furnace.<br />
N5390132 3287<br />
Components Part No. Each (€)<br />
1 2 Universal Sample Tube N5390107 714<br />
For use with the Stainless Steel Extension, 3-Point Bending,<br />
and Parallel Plate Measuring System<br />
2 2 Extension Probe Tip Holder N5390193 344<br />
Includes Probe Tip Holder Shaft (N5390112),<br />
Collet (N5391004), and Lock Nut (N5391003)<br />
Filter Clamp Assembly – Includes plate and screws<br />
3 3 Top N5390178 370<br />
4 4 Bottom N5390177 370<br />
Film Clamp Assembly<br />
5 5 Top N5390154 370<br />
6 6 Bottom N5390156 370<br />
7 7 Hex Nut 09911186 1<br />
Stainless Steel Extension<br />
Measuring System<br />
Part No. N5390132<br />
5<br />
6<br />
7<br />
2<br />
3<br />
4<br />
7<br />
1<br />
362
Mechanical Analysis (DMA)<br />
Extension and Shear Analysis Measuring Systems<br />
DMA 7/DMA 7e Quartz<br />
Extension Measuring System<br />
DMA 7/DMA 7e Quartz Extension Measuring System<br />
Used to study low-modulus materials such as thin films<br />
and fibers. Includes a fixture which provides flat parallel<br />
clamping surfaces, and a fixture which uses fiber pins and<br />
is especially suited for single filament samples. Measuring<br />
system is shipped in an attractive wooden case and also<br />
includes mounting hardware, 100<br />
fiber pins, and instructions. Used Part No. Each (€)<br />
on high-temperature furnace only.<br />
N5390134 3686<br />
DMA 7/DMA 7e Quartz<br />
Extension Measuring System<br />
and Replacement Parts<br />
Components Part No. Each (€)<br />
7 Quartz Sample Tube N5191700 523<br />
8 Quartz Probe N5190609 523<br />
9 Clamp Assembly N5190611 523<br />
Includes top and bottom clamps<br />
Sample Load Fixture N5190615 721<br />
Used to align and install sample<br />
into film sample clamps<br />
10 Fiber Pins (pkg. 100) N5390157 414<br />
10 High-Temperature Tape 02507907 56<br />
For securing thermocouple<br />
to the sample tube<br />
Shear Measuring System<br />
for Diamond DMA<br />
Diamond DMA Film Shear<br />
Measuring System<br />
Diamond DMA Shear Sandwich<br />
Measuring System<br />
Part No.<br />
Each (€)<br />
N5353031 2571<br />
Part No.<br />
Each (€)<br />
N5353030 3300<br />
7<br />
Quartz Extension Measuring System Part No. N5390134<br />
Film Shear<br />
Part No. N5353031<br />
9<br />
8<br />
Shear Sandwich<br />
Part No. N5353030<br />
10<br />
Mechanical Analysis (DMA) Thermal Analysis<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
363
Mechanical Analysis (TMA)<br />
TMA Measuring Systems<br />
Thermal Analysis Mechanical Analysis (TMA)<br />
Application Solutions<br />
with Multiple Probe Types<br />
Expansion: The expansion probe permits<br />
the direct determination of the coefficient<br />
of linear expansion, a characteristic and<br />
important property of any material.<br />
Penetration and Compression: Narrow<br />
tip compression probes are available<br />
for penetration measurements. A broad<br />
tip compression probe permits the<br />
determination of the compressive<br />
modulus and additional properties<br />
of soft rubber materials.<br />
Flexure: The deflection temperature of<br />
materials under load and other types of<br />
3-Point bending studies can be performed<br />
with the flexure analysis probe.<br />
Extension: Extension and contraction<br />
characteristics of fibers and films can<br />
be measured with this accessory.<br />
Dilatometer: Volumetric expansion<br />
and contraction can be measured with<br />
this accessory.<br />
Bending/Flexure<br />
Analysis Kits and Parts<br />
Permits deformation studies of films. Includes flexure<br />
analysis probe and platform.<br />
Product Part No. Each (€)<br />
Diamond TMA Quartz Bending Kit N5353023 3935<br />
Includes:<br />
Probe and 5 mm Platform,<br />
Diamond TMA Quartz Bending Probe N5353048 2528<br />
Diamond TMA Quartz,<br />
5 mm Bending Platform (Stage) N5353009 1688<br />
TMA 7 Flexure Analysis Kit N5190399 1135<br />
Includes:<br />
Probe and 5 mm Platform,<br />
TMA 7 Flexure Probe N5190393 619<br />
TMA 7 10 mm Flexure Analysis Sample Platform N5391181 644<br />
Dilatometer Kit<br />
Permits the determination of volumetric changes of materials<br />
as a function of temperature. The accessory is useful for<br />
materials whose linear coefficient of expansion cannot be<br />
easily determined by the expansion probe. The dilatometer is<br />
useful for determining the volume change of materials upon<br />
melting, or upon cooling from a melt. A typical application<br />
would be the determination of shrinkage from a mold.<br />
Diamond TMA<br />
Product Part No. Each (€)<br />
Includes: Sapphire Cup, Sapphire Plate, N5353095 531<br />
Probe, Alumina, and Spatula.<br />
TMA 7<br />
Product Part No. Each (€)<br />
Large Quartz Dilatometer Kit N5190763 1441<br />
1 mL capacity to be used with the large 28 mm diameter furnace<br />
Includes: Large Quartz Dilatometer Cell (barrel and plunger)<br />
Aluminum Oxide Powder 28 g<br />
Quartz Sample Tube<br />
Instruction Sheet<br />
Large Dilatometer Cell (Barrel and Plunger) N5192094 1288<br />
Small Quartz Dilatometer Kit 03190461 1467<br />
0.1 mL capacity to be used with the 15 mm diameter furnace<br />
Includes: Small Quartz Dilatometer Cell (barrel and plunger)<br />
Aluminum Oxide Powder 28 g<br />
Instruction Sheet<br />
Small Dilatometer Cell (Barrel and Plunger) 03191705 1377<br />
Aluminum Oxide Powder 04190197 49<br />
Vial of 28 g, filling medium<br />
364
Mechanical Analysis (TMA)<br />
TMA Measuring Systems<br />
Extension Analysis<br />
Kit and Parts<br />
Diamond TMA Quartz Tension Kit<br />
Allows distortion studies of drawn,<br />
spun, and cast fibers and films.<br />
Includes:<br />
Components Part No. Each (€)<br />
Diamond TMA Standard Furnace Quartz N5353041 2414<br />
Tension Probe<br />
Diamond TMA Standard Furnace Quartz N5353042 1000<br />
Tension Chuck<br />
Tool for Tension Sample Setup N5353045 620<br />
Diamond TMA Metal Tension<br />
Product Part No. Each (€)<br />
Diamond TMA Metal Tension Probe N5353043 597<br />
Diamond TMA Standard Furnace Metal Screw N5353046 165<br />
for Tension Chuck Probe (5 pcs.)<br />
Diamond TMA Standard Furnace Metal Screw N5353047 138<br />
for Tension Chuck Sample<br />
Diamond TMA Standard Furnace Tension Chuck (2) N5353044 914<br />
TMA 7 Extension Analysis Kit<br />
Comes with Sample Tube and Probe<br />
extension clamps, sample load<br />
fixture, and autozero standard.<br />
Also includes:<br />
Product Part No. Each (€)<br />
TMA 7 Extension Probe N5190609 523<br />
TMA 7 Extension Sample Tube N5191700 523<br />
TMA 7 Extension Sample Clamp N5190611 523<br />
TMA 7 Sample Load Fixture N5190615 721<br />
Used to align and install film<br />
sample into sample clamps<br />
Sample Tubes and Cylinders<br />
Diamond TMA<br />
Product Part No. Each (€)<br />
Standard Furnace Quartz Cylinder K-TC (Old-type) N5353013 1617<br />
Standard Furnace Quartz Cylinder with K-TC N5353050 1617<br />
Standard Furnace Quartz Cylinder without TC N5353054 1423<br />
Standard Furnace Metal Cylinder without TC N5353056 1051<br />
Standard Furnace Metal Cylinder with K-TC N5353052 1246<br />
High-Temperature Alumina Cylinder with N5353051 2697<br />
Platinum/Pt Rhodium Thermocouple<br />
K = Chromel/Alumel Thermocouple<br />
TMA 7<br />
Part No.<br />
Each (€)<br />
N5353021 3414<br />
Part No.<br />
Each (€)<br />
N5190619 3125<br />
Product Part No. Each (€)<br />
Quartz Sample Tube N5191549 555<br />
Required for the expansion, penetration,<br />
compression, and flexure modes of operation<br />
Quartz 3-Point Bending Sample Tube N5391181 644<br />
This tube differs from the standard sample<br />
tube in that the 10 mm bending platform is<br />
permanently fused to the base of the tube<br />
TMA 7 Expansion/Compression/<br />
Penetration Quartz Probes<br />
PerkinElmer’s quartz probes are manufactured to extremely<br />
high tolerances to ensure you obtain the most accurate data<br />
from your instrument.<br />
Product Part No. Each (€)<br />
1 Expansion Probe N5190378 504<br />
3.7 mm diameter flat tip<br />
2 Penetration Probe N5190376 504<br />
1 mm diameter flat tip<br />
3 Compression Probe<br />
0.5 mm radius spherical tip N5190377 504<br />
1.5 mm radius spherical tip N5190416 504<br />
1 2 3<br />
Diamond TMA Standard Furnace<br />
3<br />
2<br />
1<br />
Product Part No. Each (€)<br />
Aluminum Viscous Fluid Cup and N5356029 755<br />
Pin Set for Curing Studies<br />
Quartz Conical Penetration Probe N5353040 2526<br />
Quartz Penetration Probe (0.5 mm) N5353039 2571<br />
Quartz Penetration Probe (1.0 mm) N5353038 1571<br />
Quartz Sample Stage (5 pcs.) N5353057 263<br />
Quartz Expansion Probe N5353036 1197<br />
Diamond TMA High-Temperature Furnace<br />
Product Part No. Each (€)<br />
Alumina Expansion Probe N5353037 1106<br />
Alumina Sample Stage (5 pcs.) N5353059 763<br />
Mechanical Analysis (TMA) Thermal Analysis<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
365
Mechanical Analysis (TMA/DMA)<br />
Furnace Accessories, Reference Materials, and Supplies<br />
Thermal Analysis Mechanical Analysis (TMA/DMA)<br />
Diamond DMA/TMA Calibration<br />
Reference Materials and Tools<br />
Diamond DMA<br />
Product Part No. Each (€)<br />
Aluminum Plate N5353073 109<br />
PMMA, 0.2 x 8 x 40 mm N5353076 71<br />
PMMA, 1.5 x 10 x 50 mm N5353077 71<br />
Pure Iron Plate N5353074 263<br />
Stainless Steel Plate N5353075 237<br />
Diamond TMA<br />
Product Part No. Each (€)<br />
Aluminum Standard Cylinder for Standard Furnace N5353065 83<br />
Quartz Standard Cylinder for High-Temperature Furnace N5353140 203<br />
Diamond DMA/TMA Furnace<br />
Tubes, Thermocouples,<br />
and Accessories<br />
Diamond DMA<br />
Product Part No. Each (€)<br />
Immersion Liner N5353141 686<br />
Used to analyze samples in liquids. Temperature range:<br />
Rate to 80 °C (upper limit depends on liquid), Purge Gas:<br />
requires 1000 mL/min. or more dry air or nitrogen,<br />
Immersion liquid volume: maximum 15 mL.<br />
Diamond TMA<br />
Product Part No. Each (€)<br />
Front Plate for Vacuum Operation N5353116 1809<br />
Quartz Vacuum Accessory Kit N5353114 3619<br />
Standard Furnace<br />
Alumina Vacuum Accessory Kit N5353115 3333<br />
Immersion Studies Tube N5353144 7100<br />
Quartz Furnace Tube N5353062 1611<br />
Quartz Vacuum Furnace Tube N5353117 1809<br />
Thermocouple K-TC N5353060 194<br />
High-Temperature Furnace<br />
Alumina Furnace Tube N5353063 1351<br />
Alumina Vacuum Furnace Tube N5353118 1809<br />
Thermocouple R-TC N5353061 420<br />
5<br />
1<br />
2<br />
6 7<br />
8<br />
3<br />
4<br />
9<br />
DMA 7, DMA 7e, and TMA7<br />
Reference Materials<br />
10<br />
Components Part No. Each (€)<br />
1 Force Calibration Weight, 50 g 09908825 16<br />
2 Micrometer 09907281 332<br />
3 TMA 7 Extension Autozero Cylinder N5191792 46<br />
4 DMA Epoxy Reference Material (pkg.10) N5390128 191<br />
5 Zero Step Block for SS 3-Point Bending<br />
20 mm N5391090 91<br />
15 mm N5391104 148<br />
10 mm N5391184 191<br />
6 Eigendeformation Calibration Cylinder N5191469 9<br />
7 DMA 10 mm Height Calibration Cylinder N5391051 56<br />
8 Aluminum Cylinder 02191858 73<br />
for Expansion Measurement<br />
Indium Temperature 03190033 29<br />
Calibration Reference Material<br />
Zinc Temperature 03190036 38<br />
Calibration Reference Material<br />
Dual Cantilever Height Calibration Aid N5391085 90<br />
Sapphire Disk 02191269 125<br />
for TMA Ordinate Calibration<br />
DMA 7, DMA 7e, and TMA7<br />
Thermocouples, Furnaces,<br />
and Supplies<br />
Components Part No. Each (€)<br />
9 DMA/TMA 7 Sample Thermocouple N5190417 64<br />
10<br />
DMA Ceramic Thermocouple Insulator N5391048 23<br />
High-Temperature Tape 02507907 56<br />
for securing thermocouple<br />
to the sample tube<br />
Non-Magnetic Straight Tweezers 09908400 60<br />
Buoyancy Fluid 02190218 427<br />
DMA High-Temperature Furnace Install Kit N5390141 3482<br />
Designed to add High-Temperature<br />
capability to a DMA 7<br />
Includes heat sink, insulator, and<br />
High-Temperature furnace<br />
TMA 7 Large Furnace Install Kit N5190617 4349<br />
Designed to add large furnace<br />
capability to a TMA 7<br />
Includes heat sink, insulator, and<br />
large furnace<br />
Replacement DMA/TMA 7 Furnace<br />
Large, 28 mm i.d. (to 500 °C) N5190613 3482<br />
Small, High-Temperature 15 mm i.d. N5190370 2372<br />
(to 1000 °C)<br />
366
Calibration Reference Materials<br />
Description Transition Point Part No. Each (€)<br />
Aluminum 660.10 °C N5380057 18<br />
Gold 1063.00 °C N5380058 90<br />
Indium 156.60 °C 03190033 29<br />
Lead 327.47 °C 03190035 43<br />
Palladium 1551.85 °C N5380071 29<br />
Tin 231.88 °C 03190034 75<br />
Zinc 419.47 °C 03190036 38<br />
Furnace and Furnace Accessories<br />
Diamond Air Cooling and Gas Switching Accessory<br />
3 Channels: one to cool down furnace<br />
and the other two for gas switch.<br />
Balance Beam Socket Set for Diamond TG/DTA<br />
Plug-in type, Set of 2 alumina beams<br />
for sample and reference side,<br />
includes Thermocouple.<br />
Furnace Tube Standard<br />
Furnace Tube for Corrosive Gas<br />
Furnace Tube Vacuum<br />
Part No.<br />
TG/DTA Supplies and Accessories<br />
Each (€)<br />
N5350202 2532<br />
Part No.<br />
Each (€)<br />
N5352006 2381<br />
Part No.<br />
Each (€)<br />
N5352004 1825<br />
Part No.<br />
Each (€)<br />
N5352027 2644<br />
Part No.<br />
Each (€)<br />
N5352005 3174<br />
Diamond TG/DTA Supplies and Accessories<br />
Hyphenated Accessories<br />
Diamond TG/DTA Gas Transfer<br />
System Standard Unit<br />
Controller for heated transfer line.<br />
Gas Transfer Accessory for FTIR<br />
Heated transfer line – requires<br />
Gas Transfer System (N5350201)<br />
for temperature control.<br />
Gas Transfer Accessory for MS<br />
Heated transfer line – requires<br />
Gas Transfer System (N5350201)<br />
for temperature control.<br />
In-Line Filter Trap for<br />
Diamond TG/DTA<br />
Part No.<br />
Each (€)<br />
N5350201 6900<br />
Part No.<br />
Each (€)<br />
N5350203 714<br />
Part No.<br />
Each (€)<br />
N5350204 4285<br />
The In-line Filter Trap removes moisture, oil, and dust from<br />
the gases before they flow into your instrument. It consists<br />
of a transparent acrylic tube containing a molecular sieve<br />
and a desiccant, Drierite. An indicator changes color to let<br />
you know when the packing must be changed, while the<br />
cartridge design makes replacement of the filter material easy.<br />
Product Part No. Each (€)<br />
In-Line Filter Trap N9301178 200<br />
In-Line Filter Trap Refill Kit N9301176 29<br />
Sample Pans<br />
Description Qty. Part No. Each (€)<br />
Alumina Sample Pans, 25 uL Set of 5 N5356019 174<br />
Alumina Sample Pans, 55 uL Set of 2 N5356020 333<br />
Aluminum Cover for Autosampler Pans Set of 400 N5356026 238<br />
Aluminum Open Sample Pan Set of 400 N5356012 269<br />
Aluminum Open Sample Pan, 50 uL Set of 400 N5356025 238<br />
Aluminum Open Sample Pan, 90 uL Set of 200 N5356034 286<br />
Copper Mesh Cover Set of 200 N5356022 88<br />
Used with N5356021<br />
to fix sample position<br />
Copper, Open Sample Pan, 45 uL Set of 200 N5356021 255<br />
Platinum Cover for Open Pan Set of 5 N5356018 174<br />
Platinum, Open Sample Pan, 45 uL Set of 5 N5356016 507<br />
Platinum, Open Sample Pan, 90 uL Set of 5 N5356017 507<br />
Stainless Steel Mesh Cover Set of 200 N5356023 88<br />
TG/DTA Supplies and Accessories Thermal Analysis<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
367
TGA Supplies and Accessories<br />
Calibration Reference Materials<br />
Thermal Analysis TGA Supplies and Accessories<br />
Calibration Reference Materials for Temperature Calibration<br />
of PerkinElmer TGA Furnaces Pyris 1 TGA, TGA 6, and TGA 7<br />
Ensure accurate thermogravimetric measurements with<br />
PerkinElmer magnetic reference materials.<br />
Kit of Five Reference Materials<br />
Including Alumel, Nickel, Perkalloy,<br />
Iron, and Hisat-50 (one piece each).<br />
Alumel Reference Material<br />
Three 2 in. pieces of Alumel wire.<br />
Magnetic transition temperature<br />
of 154.2 °C.<br />
Nickel Reference Material<br />
Three 2 in. pieces of 99.99% Nickel<br />
wire. Magnetic transition temperature<br />
of 355.3 °C.<br />
Perkalloy Reference Material<br />
Three 2 in. pieces of Perkalloy wire.<br />
Magnetic transition temperature<br />
of 596 °C.<br />
Iron Reference Material<br />
Three 2 in. pieces of 99.99% Iron wire.<br />
Magnetic transition temperature<br />
of 780 °C.<br />
Part No.<br />
Each (€)<br />
02190071 102<br />
Part No.<br />
Each (€)<br />
09988015 66<br />
Part No.<br />
Each (€)<br />
N5190869 66<br />
Part No.<br />
Each (€)<br />
N5190616 66<br />
Part No.<br />
Each (€)<br />
09988017 66<br />
Magnetic Calibration Reference Materials are available in kit form and now are<br />
also available separately for your convenience. We recommend that you use<br />
fresh reference materials each time you calibrate your instrument. In this way<br />
you can avoid the effects of hysteresis and oxidation on the Curie point of the<br />
reference materials.<br />
368
TGA Supplies and Accessories<br />
Furnace and Furnace Accessories<br />
Conversion Kits*<br />
PYRIS 1 TGA Standard to<br />
High-Temperature Conversion Kit<br />
Designed to add high-temperature<br />
furnace capability to a PYRIS 1 TGA<br />
equipped with a standard furnace.<br />
PYRIS 1 TGA High-Temperature to<br />
Standard Conversion Kit<br />
Designed to add standard furnace<br />
capability to a TGA equipped with<br />
a high-temperature furnace.<br />
TGA 7 Standard Furnace Install Kit<br />
Designed to add standard furnace capability to a TGA 7<br />
Thermogravimetric Analyzer<br />
with high-temperature furnace.<br />
Part No. Each (€)<br />
TGA 7 High-Temperature Furnace Install Kit<br />
Designed to add high-temperature furnace capability to a<br />
TGA 7 Thermogravimetric Analyzer<br />
equipped with the standard furnace.<br />
Part No. Each (€)<br />
N5190510 12500<br />
* PerkinElmer Service installation required.<br />
Furnace Accessories and<br />
Glassware for TGA Standard<br />
and High-Temperature<br />
1<br />
2<br />
Standard TGA TGA High-Temperature<br />
Components Part No. Each (€) Part No. Each (€)<br />
Furnace N5190264 1862 N5190172 7900<br />
Furnace Thermocouple N5190196 459<br />
Cup for Furnace N5191875 579<br />
Thermocouple<br />
Sample Thermocouple 03190253 421 N5190197 644<br />
Sample Thermocouple N5190786 861<br />
Furnace Tube Quartz<br />
TGA 7 N5190203 344<br />
PYRIS 1 TGA N5370459 344 N5190202 548<br />
Platinum Furnace Shield 03191628 893<br />
PRYIS 6 TGA<br />
Part No.<br />
Each (€)<br />
N5370332 12100<br />
Part No.<br />
Each (€)<br />
N5370331 3813<br />
N5190511 6300<br />
Description Part No. Each (€)<br />
Ceramic Sample Cup Holder N5203020 332<br />
Replacement Furnace Thermocouple N5376817 279<br />
Replacement Sample Thermocouple N5376806 386<br />
Calibration Weight for PYRIS 6 TGA N5200042 47<br />
Components Part No. Each (€)<br />
1 3 Balance Platinum Ribbon Kit* N5370478 712<br />
1 4 Balance Tare Weight N5190284 110<br />
for TGA 7 High-Temperature<br />
1 4 Balance Tare Weight N5190282 110<br />
for TGA 7 Standard<br />
1 5 O-Ring, used under Balance Cover 09902163 25<br />
5 7/8 in. o.d. x 1/8 in. wide<br />
1 O-Ring, Ball Joint 09902131 10<br />
1 7/16 in. o.d. x 1/8 in. wide<br />
1 O-Ring, Split, used at TGA 7 09902031 3<br />
Standard Furnace Mount<br />
1 7/8 in. o.d. x 3/16 in. wide<br />
1 Fuse 09981785 4<br />
12 A, 250 V (Line Power)<br />
* PerkinElmer Service installation required.<br />
3<br />
6<br />
7<br />
8<br />
9<br />
4<br />
1<br />
2<br />
5<br />
Standard Furnace TGA<br />
TGA Supplies and Accessories Thermal Analysis<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
369
TGA Supplies and Accessories<br />
Furnace and Furnace Accessories<br />
Thermal Analysis TGA Supplies and Accessories<br />
TGA Accessories and Supplies<br />
PYRIS 1 TGA Accupik Replacement Needle Kit<br />
Contains 3 needles.<br />
PYRIS 1 TGA Cooling Jacket<br />
With this accessory and C 6<br />
Chiller (optional), the TGA<br />
can start from -20 °C.<br />
PYRIS TGA Volatile Sealer Tool<br />
PYRIS TGA Volatile<br />
Capsule Sealer Kit<br />
Tube Clamp for PYRIS 1 TGA<br />
3/8 in. diameter.<br />
Antistatic Compound, Liquid<br />
Apply to the outside of the glassware<br />
to reduce static electricity.<br />
Static Discharge Kit, TGA Furnace<br />
Includes conductive tube, conductive<br />
grease, gasket, O-Ring, and instructions.<br />
Designed for labs prone to static problems.<br />
TGA Furnace Conductive Tube<br />
Forceps, Non-Magnetic<br />
Description Part No. Each (€)<br />
Hooked 09908138 66<br />
Straight 09908400 60<br />
Antistatic Compound, Liquid<br />
for TGA 7 High-Temperature<br />
Apply to the outside of the glassware<br />
to reduce static electricity.<br />
100 mg Calibration Weight<br />
for TGA 1 and PYRIS 1 TGA<br />
Part No.<br />
Part No.<br />
Each (€)<br />
N5370552 568<br />
Part No.<br />
Each (€)<br />
N5370555 204<br />
Part No.<br />
Each (€)<br />
09903011 3<br />
Part No.<br />
Each (€)<br />
09905932 65<br />
Part No.<br />
Each (€)<br />
N5190512 2949<br />
Part No.<br />
Each (€)<br />
N5191552 2621<br />
Part No.<br />
Each (€)<br />
09905932 65<br />
Part No.<br />
Each (€)<br />
N5370554 210<br />
Part No.<br />
Each (€)<br />
N5370553 1518<br />
Each (€)<br />
09908397 153<br />
370
TGA Supplies and Accessories<br />
Hangdown Wires, Sample Pans, and Supplies<br />
Hangdown Wire Kits<br />
6<br />
7<br />
7<br />
7<br />
8<br />
TGA 7 Standard TGA 7 High Temperature PYRIS 1 TGA Standard PYRIS 1 TGA High Temperature<br />
Description Material Qty. Part No. Each (€) Part No. Each (€) Part No. Each (€) Part No. Each (€)<br />
Hangdown Wire Link Kit Quartz 10 N5190330 217<br />
Hanger Kit Quartz 5 N5370487 263<br />
Autosampler Hanger Kit Quartz 5 N5370488 275<br />
Hangdown Wire Kit Nichrome 6 N5190285 306<br />
Includes 6 preformed and 6 straight wires<br />
Hangdown Wire Kit Nichrome 6 N5190516 140<br />
Includes 6 preformed wires<br />
Hangdown Wire Kit Nichrome 6 N5190515 124<br />
Includes 6 straight wires<br />
Autosampler Hanger Kit Nichrome 5 N5370490 101<br />
Hanger Kit Platinum 6 N5370330 409<br />
Hangdown Wire Kit Platinum 6 N5190276 414<br />
Includes 6 preformed wires<br />
Stirrup Kit Platinum 4 03190265 536 N5190279 548 03190265 536 N5190279 548<br />
Nichrome Hangdown Wire Kit<br />
Part No. N5190285<br />
Quartz Hangdown Wire Link Kit<br />
Part No. N5190330<br />
Platinum Stirrup Kit<br />
Part No. 03190265<br />
Platinum Hangdown Wire Kit<br />
Part No. N5190276<br />
6<br />
7<br />
8<br />
High-Temperature Furnace TGA<br />
TGA Supplies and Accessories Thermal Analysis<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
371
TGA Supplies and Accessories<br />
Hangdown Wires, Sample Pans, and Supplies<br />
Thermal Analysis TGA Supplies and Accessories<br />
Sample Pans, Covers, and Supplies<br />
Platinum Sample Pan Kits<br />
9<br />
9<br />
Description Part No. Each (€)<br />
Sample Pan Kit 03190264 772<br />
for TGA 7 Standard/PYRIS 1 TGA,<br />
Includes 4 pans<br />
Sample Pan Kit N5190280 1149<br />
for TGA 7/PYRIS 1 TGA<br />
High-Temperature, Includes 4 pans<br />
Gold Volatile Pans and Covers<br />
for TGA 7/PYRIS 1 TGA<br />
For use with the TGA 7 or PYRIS 1 TGA (after making a<br />
pinhole) from room temperature to 1000 °C with gold pans<br />
for maintenance of vapor phase over sample. Requires<br />
Sample Sealer Assembly (02190061) for sealing or Universal<br />
Crimper Press (B0139005), with<br />
Sealing Insert (B0144637). 10 of each. Part No. Each (€)<br />
Aluminum Vapor Pressure Pan Kit<br />
for TGA 7/PYRIS 1 TGA<br />
This kit includes 100 volatile aluminum pans and 100<br />
pierced covers. A 50-micron diameter hole is centered in<br />
the cover. Use this kit for more reproducible measurements<br />
of boiling points, heats of vaporization, and sublimation<br />
temperatures. Vapor pressure studies can be conducted<br />
when using these pans and covers with the High Pressure<br />
DSC or the TGA. Maximum temperature is 600 °C. Requires<br />
Sample Sealer Assembly (02190061) for sealing or Universal<br />
Crimper Press (B0139005) with<br />
Sealing Insert (B0144637). 100 of each. Part No. Each (€)<br />
PYRIS 1 TGA Accupik Sample Pan and Covers<br />
Maximum temperature is 600 °C.<br />
400 pieces.<br />
Platinum Sample Pan Kit<br />
Part No. 03190264<br />
02190080 1078<br />
N5190788 300<br />
Part No.<br />
Each (€)<br />
N5370550 529<br />
Ceramic Liner Kit for TGA 7/PYRIS 1 TGA<br />
High-Temperature Sample Pans.<br />
Includes 6 covers and 6 liners.<br />
PYRIS 1 TGA Autosampler Ceramic Crucible Kit<br />
Contains 10 ceramic crucibles.<br />
Part No.<br />
PYRIS 6 TGA Sample Pans and Accessories<br />
Each (€)<br />
N5190283 644<br />
Part No.<br />
Each (€)<br />
N5370464 163<br />
Description Part No. Each (€)<br />
Sample Pan Kit for TGA 6 N5200040 118<br />
PYRIS 6 TGA Sample Holder N5203020 332<br />
Sample Pan Kit for TGA 6<br />
Part No. N5200040<br />
372
Thermal Analysis Software<br />
PYRIS Software<br />
PYRIS Series Advanced Software<br />
Additional Data Processing Power to Handle<br />
Your Laboratory’s Demanding Tasks<br />
A variety of thermal analysis software packages are<br />
available from PerkinElmer to allow you to perform specific<br />
tasks. Whether you need to determine absolute purity or<br />
kinetic parameters that characterize a reaction process, we<br />
have the software to handle the job.<br />
Temperature Dependent Crystallinity Software<br />
for PYRIS Users<br />
Contains the program disks and installation instructions. This<br />
version is for use directly from PYRIS Software for Windows<br />
without the need for manual conversion<br />
of the ASCII data files. Does not contain<br />
a separate security holder.<br />
Part No.<br />
N5370637<br />
Each (€)<br />
332<br />
DSC and DTA Kinetics Software<br />
Use these packages to obtain the kinetic parameters that<br />
characterize thermally initiated reactions. These programs<br />
use multilinear Regression Analysis (for the 7 Series and<br />
the 7 Series/UNIX software only). Contact your local<br />
salesperson for available options.<br />
Description Part No. Each (€)<br />
PYRIS DSC Scanning Kinetics Software (Single-user) N5370667 2627<br />
PYRIS DSC Isothermal Kinetics Software (Single-user) N5370668 2627<br />
PYRIS DSC Advanced Software Suite (Single-user) N5370610 4256<br />
PYRIS Model Free Kinetics (MFK) Software (Single-user) N5370638 1064<br />
TGA Decomposition Kinetics Software<br />
Allows calculation of the kinetics constants from multiple<br />
heating rate TG curves using from three to six data curves.<br />
Contact your local salesperson for available options.<br />
Description Part No. Each (€)<br />
PYRIS Model Free Kinetics (MFK) Software (Single-user) N5370638 1064<br />
PYRIS TGA Decomposition Kinetics (Single-user) N5370669 2627<br />
PYRIS TGA Advanced Software Suite (Single-user) N5370616 3192<br />
Includes: PYRIS 1 TGA and Diamond TG/DTA<br />
Decomposition Kinetics and PYRIS 1 TGA<br />
AutoStepwise Advanced Software<br />
DSC/TGA<br />
PYRIS Advanced Kinetics Software Suite (Single-user) N5370647 3724<br />
PYRIS Advanced Kinetics Software Suite (2+users) N5370648 1436<br />
Includes: PYRIS Series DSC Scanning Kinetics,<br />
DSC Isothermal Kenetics, DSC/TGA MFK, TGA<br />
Decomposition Kinetics<br />
PYRIS DSC Step Scan Software<br />
The PYRIS StepScan software provides the ability to<br />
determine accurate specific heat capacity (Cp) under a<br />
variety of conditions. StepScan produces a temperature<br />
program that consists of a series of short temperature steps.<br />
After each step, the heat flow is equilibrated until a criterion<br />
is satisfied, and then the next step is started. This produces<br />
a series of peaks. Available for both Diamond DSC and the<br />
PYRIS 1 DSC. It requires the PYRIS<br />
Software v3.7 or above.<br />
Part No. Each (€)<br />
PYRIS Series DSC Specific Heat Advanced Software<br />
(Single-User )<br />
Because the PYRIS 1 DSC and the DSC 7 provide a linear<br />
energy measurement over a wide temperature range, the<br />
two-curve Specific Heat Software allows the user to run a<br />
baseline and sample to calculate the Cp and enthalpy<br />
change of the sample. The three-curve method enables the<br />
analyst to be consistent with ASTM Method 1269E which<br />
requires sample, baseline, and reference runs for analysis of<br />
Cp and enthalpy change of the sample. Includes: one-, two-,<br />
and three-curve Specific Heat calculation<br />
capability for use on a single PC. Part No. Each (€)<br />
PYRIS Series DSC Purity Advanced Software<br />
(Single-User )<br />
N5370679 3192<br />
N5370665 2660<br />
This software package enables the analyst to determine the<br />
absolute purity of a sample. It also can identify the sample<br />
purity even if the sample decomposes during melting. The<br />
ideal melting point and the actual melting point may also be<br />
calculated. A Van’t Hoff plot is calculated and displayed by<br />
the software. The heat of fusion and melting point depression<br />
can be determined. Includes: one-, two-,<br />
and three-curve Specific Heat calculation Part No. Each (€)<br />
capability for use on a single PC.<br />
N5370666 3290<br />
PYRIS Enhanced Security Software (Single-User )<br />
In response to 21 CFR Part 11 and the increasing data<br />
security requirements in other industries, PerkinElmer’s<br />
PYRIS Enhanced Security TM (ES) option offers the<br />
technical compliance tools needed<br />
to meet these mandatory regulations. Part No. Each (€)<br />
N5370680 3192<br />
Thermal Analysis Software Thermal Analysis<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
373
Thermal Analysis Software<br />
PYRIS Software<br />
Thermal Analysis Thermal Analysis Software<br />
PYRIS Series Thermal<br />
Analysis Manager Software<br />
PYRIS Series Thermal Analysis Manager<br />
(Single-User )<br />
For control and operation of up to<br />
eight thermal analyzers of any type<br />
from a single PC controller.<br />
PYRIS Series Thermal Analysis<br />
Manager Additional Licenses<br />
(2-10 )<br />
PYRIS Series Multi-User IC License<br />
For those customers that require additional instrument<br />
control of their thermal analyzers from remote locations,<br />
such as in different laboratories<br />
within one facility, order one for<br />
each additional license.<br />
Part No.<br />
N5370606<br />
Each (€)<br />
1064<br />
PYRIS Series TMA/DMA<br />
Advanced Software<br />
PYRIS Series DMA 7/7e Advanced Software Suite<br />
(Single User )<br />
All DMA 7/7e Advanced Software Packages listed below are<br />
included for use on a single PC. Includes: DMA Frequency<br />
Scan Advanced Software (N5370674), DMA Dynamic Stress<br />
Scan Advanced Software (N5370675), DMA Frequency<br />
Multiplexing Advanced Software (N5370673), DMA Time/<br />
Temperature Superposition Advanced Software (N5370676),<br />
TMA/DMA Static Stress Scan Advanced<br />
Software (N5370671), TMA/DMA Creep<br />
Part No. Each (€)<br />
Recovery Advanced Software (N5370672). N5370622 7700<br />
PYRIS Series DMA 7/7e Advanced<br />
Software Suite Additional Licenses<br />
PYRIS Series DMA 7/7e<br />
Frequency Multiplexing Software<br />
Part No.<br />
Each (€)<br />
N5370600 6200<br />
Part No.<br />
Each (€)<br />
N5370603 186<br />
Part No.<br />
Each (€)<br />
N5370623 213<br />
This software enables the analyst to easily set up in one<br />
method a series of DMA Frequency Scans at different<br />
temperatures. This type of method<br />
is well-suited for Time/Temperature<br />
Superposition analysis.<br />
Part No.<br />
N5370673<br />
Each (€)<br />
3192<br />
PYRIS Series TMA/DMA Static Stress Scan Software<br />
In static stress scan mode, the static stress applied to the<br />
sample material is programmed over a specific range with<br />
time. Temperature is held constant and there is no dynamic<br />
component. Stress-dependent behavior is characterized by<br />
monitoring changes in strain. This mode<br />
is useful for the evaluation of the stress<br />
dependence of a physical structure.<br />
Part No.<br />
N5370671<br />
Each (€)<br />
3192<br />
PYRIS Series DMA Time/Temperature<br />
Superposition Software<br />
This analytical package utilizes data generated from frequency<br />
scans or Frequency Multiplex scans. A master curve is created<br />
(superimposed) from a series of frequency scans at different<br />
temperatures. The master curve is based on the WLF<br />
(Williams-Landell-Ferry) equations. A master curve is used to<br />
predict long-term mechanical behavior of a material. This is<br />
particularly applicable to amorphous,<br />
Part No. Each (€)<br />
linear, and cross-linked polymers as<br />
well as other materials.<br />
N5370676 3192<br />
PYRIS Series TMA 7 Advanced Software Suite<br />
(Single-User )<br />
All TMA 7 Advanced Software Packages listed below are<br />
included for use on a single PC. Includes: TMA/DMA Static<br />
Stress Scan Advanced Software<br />
(N5370671), TMA/DMA Creep Recovery<br />
Advanced Software (N5370672).<br />
Part No.<br />
N5370619<br />
Each (€)<br />
4256<br />
PYRIS Series TMA 7 Advanced<br />
Software Suite Additional Licenses<br />
Part No.<br />
Description Part No. Each (€)<br />
PYRIS DSC Advanced Software Suite (Single-user) N5370610 4256<br />
PYRIS DSC Advanced Software Suite (2+users) N5370611 1436<br />
PYRIS Series DMA 7/7e Frequency Scan Software<br />
Allows you to operate the DMA in a frequency scan mode<br />
where the frequency of oscillation is programmed over a<br />
specific and continuous range with time. Both temperature<br />
and stress are held constant in this mode. Rate-dependent<br />
behavior is characterized by monitoring the change in strain<br />
and phase over time. The frequency scan<br />
mode is a valuable tool for characterizing<br />
Part No. Each (€)<br />
or fingerprinting materials.<br />
N5370674 3192<br />
PYRIS Series DMA 7/7e Creep-Recovery Software<br />
Each (€)<br />
N5370620 213<br />
Use the Creep-recovery software to instantaneously apply<br />
a stress and hold it at the programmed constant value for<br />
a programmed time, and then instantaneously remove the<br />
stress. Time and stress-dependent behavior is characterized<br />
by monitoring the strain. Compliance, modulus, and stress<br />
are calculated and displayed on the screen as a Retardation<br />
Spectrum. The creep-recovery mode is used to generate<br />
modulus and viscosity values at long times (very low<br />
frequencies) that are not within practical limits of instrumental<br />
testing. A programmed ramped static<br />
force is now available as part of each<br />
Part No. Each (€)<br />
package for mechanical hysteresis. N5370672 2660<br />
PYRIS Series DMA 7/7e Dynamic Stress Scan Software<br />
In the Dynamic Stress Scan mode, the dynamic stress applied<br />
to the sample material is programmed over a specific range<br />
with time. Temperature and frequency are held constant.<br />
Stress-dependent behavior is characterized by monitoring<br />
changes in strain. This mode is useful for the evaluation of<br />
the stress dependence of a physical structure. It is also used<br />
to aid in the selection of the stress<br />
parameter used in the other DMA 7<br />
Part No. Each (€)<br />
modes of operation.<br />
N5370675 3192<br />
374
Ultramicrobalance Supplies<br />
Weights, Forceps, Stirrups, and Pans<br />
AD-6 Ultramicrobalance<br />
Provides highly accurate weighing of your samples<br />
Features a maximum sensitivity of 0.1 μg<br />
and a capacity of 5.0 g<br />
Allows easy access to the weighing chamber for both<br />
right-and left-handed analysts<br />
Communicates your results to a printer or a computer<br />
via an optional RS-232C interface<br />
Designed for high-performance weighing procedures<br />
Microcomputer controlled<br />
Autobalance Accessory Kit<br />
Includes non-magnetic stainless steel forceps, tare weight set,<br />
Class M calibrating weight, flat<br />
sample pans, and spare fuses.<br />
Part No. Each (€)<br />
Forceps<br />
Product Part No. Each (€)<br />
Non-Magnetic, Nonserrated Stainless Steel Straight 09908400 60<br />
Non-Magnetic, Hooked 09908138 66<br />
Manuals<br />
Product Part No. Each (€)<br />
Autobalance Quick Reference Guide 09937138 48<br />
AD-6 Instruction Manual C0991141 65<br />
Repair Kit<br />
Hangdown Wire Repair Kit<br />
Use to repair one wire for the<br />
AD-2/AD-4/AD-6 Balance.<br />
Sample Pans<br />
Product Pkg. Part No. Each (€)<br />
Aluminum Flat Pans<br />
For Standard Stirrup Kit 20 C3221027 99<br />
Stirrup Kit<br />
Standard Stirrup Kit<br />
Includes two matched stirrups.<br />
Weight and Weight Sets<br />
03220067 429<br />
Part No.<br />
Each (€)<br />
C3220112 125<br />
Part No.<br />
Each (€)<br />
03220068 179<br />
Description Part No. Each (€)<br />
Class 1.1 Calibrating Weight (per ASTM E617,100 mg) 09908397 153<br />
Tare Weight Set 09908396 56<br />
Includes: 13 weights ranging from 1 mg to 1 g<br />
AD-6 Ultramicrobalance<br />
Non-Magnetic,<br />
Nonserrated Stainless<br />
Steel Straight Forceps<br />
Part No. 09908400<br />
Tare Weight Set<br />
Part No. 09908396<br />
Standard Stirrup Kit<br />
Part No. 03220068<br />
Non-Magnetic, Hooked Forceps<br />
Part No. 09908138<br />
Aluminum Flat Pans<br />
Part No. C3221027<br />
Part No. C3221047<br />
Class 1.1 Calibrating Weight<br />
Part No. 09908397<br />
Ultramicrobalance Supplies Thermal Analysis<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
375
®
PerkinElmer has been an industry leader in UV/Vis/NIR and UV/Vis instrumentation for almost<br />
50 years, and we continue to innovate with our LAMBDA Series of spectrophotometers,<br />
with exclusive features such as the Universal Reflectance Accessory (URA). Offering sampling<br />
flexibility and superior data quality, PerkinElmer instruments are the standard in thousands of<br />
laboratories, in multiple industries worldwide.<br />
The LAMBDA 25/35/45 UV/Vis spectrophotometers increase productivity by generating<br />
accurate results the first time, every time. The new high-performance LAMBDA 950, 850<br />
and 650 UV/Vis/NIR and UV/Vis spectrophotometers deliver high performance, flexibility<br />
and convenience. Each model includes the same range of modular components and snap-in<br />
accessories to tackle a range of tough applications. These LAMBDA systems are easy to<br />
operate and deliver results you can trust, and are supported by the worldwide service and<br />
support of PerkinElmer.<br />
UV Visible
UV Visible<br />
QUICK-FIND INDEX Page #<br />
Calibration Reference<br />
Materials 395<br />
Cell Changers and<br />
Accessories 387<br />
Cell Holders 388<br />
Cells for Spectroscopy 390<br />
Cylindrical Cells 391<br />
Deuterium and Tungsten<br />
Source Lamps 397<br />
Fiber Optic Accessories 380<br />
Flow-through Cells 391<br />
General Purpose Optical<br />
Bench Kits 380<br />
Integrating Sphere Accessories 381<br />
Macro Cells 392<br />
Micro Cells 393<br />
Polarimetry Supplies 399<br />
Polarizer/Depolarizer<br />
Accessories 382<br />
Research Peltier System 386<br />
Routine Peltier Systems 385<br />
Semi-micro Cells 393<br />
Sippers and Sipper<br />
Accessories 382<br />
Specular Reflectance<br />
Accessories 384<br />
PerkinElmer offers a wide selection of superior quality products designed to work with<br />
your PerkinElmer instruments. Our precision-designed products deliver the peace of<br />
mind that comes from knowing that you’ll get the results you need.<br />
The Quick Find Index to the left will help you find products fast. For your convenience,<br />
products are alphabetized by category, sub-category, and family. There is also a more<br />
complete Alphabetical INDEX on page 429 and a Part Number INDEX on page 407.<br />
Deuterium and Tungsten Source Lamps<br />
Cells for Spectroscopy<br />
Calibration Reference Materials<br />
For optimum instrument performance, always use original<br />
replacement Source Lamps from PerkinElmer. Our extensive<br />
quality control and inspection process ensures the very<br />
best quality sources. This guarantees top performance and<br />
maximum stability from your UV/Vis Spectrophotometer.<br />
Page 397<br />
PerkinElmer cells ensure top optical performance, with high<br />
cell transmission and accurate pathlength. The cell windows<br />
are fused to the bodies by a special process which avoids<br />
deformation of the windows. This assures that the full<br />
width of the cell is usable and the finished cell dimensions<br />
are maintained.<br />
Page 390<br />
PerkinElmer Reference Materials speed calibration<br />
verification of UV/Vis and UV/Vis/NIR Spectrophotometers,<br />
providing laboratory managers with the evidence they need<br />
to pass the strictest quality audit. A USA-based calibration<br />
laboratory ensures a reliable two-week turnaround service<br />
for periodical recalibrations.<br />
Page 395<br />
Ultra-micro Cells 394<br />
UV/Vis Software 398<br />
8+1 Cell Changer<br />
A range of automatic linear cell changers speeds and<br />
simplifies multi-sample measurements and quantitative<br />
calibrations. The 8+1 Cell Changer is an automatic water<br />
thermostattable, automatic linear cell changer, for eight<br />
samples and one reference. It includes the Automatic<br />
Linear Transport, 8-Cell Holder Water Thermostattable and<br />
Water Thermostattable Reference Cell Holder.<br />
Page 387
LAMBDA Spectrophotometers<br />
Proven Technology that Delivers<br />
Consistently High Quality Results<br />
PerkinElmer provides a range of UV/Vis and<br />
UV/Vis/NIR spectrophotometers, software,<br />
sampling accessories and services to help<br />
you improve product quality, productivity<br />
and analytical processes.<br />
LAMBDAs are the preferred choice of busy teaching, materials<br />
research and bio-research laboratories, where the PerkinElmer<br />
name is synonymous with quality, performance and reliability.<br />
LAMBDA 950<br />
LAMBDA 25/35/45<br />
PerkinElmer’s Lambda TM 25/35/45 UV/Vis<br />
systems increase productivity by mimicking<br />
the QA workflow to generate high quality<br />
results the first time, every time. The<br />
Lambda systems are easy to operate and<br />
deliver results you can trust with the<br />
minimum of operator training – it’s easy<br />
to develop simple, robust methods and<br />
ensure they’re followed without mistakes.<br />
With more than 10,000 units installed<br />
world-wide our superior technology and<br />
build quality has proven itself under the<br />
toughest conditions.<br />
Features:<br />
■ True double-beam operation provides the best<br />
possible stability and allows references to be<br />
measured and corrected in real-time<br />
■ Sealed and quartz coated high throughput optics<br />
ensure consistently high performance throughout<br />
the instrument’s service life<br />
LAMBDA 950, 850, and 650<br />
The new LAMBDA 950, 850, and 650<br />
UV/Vis/NIR and UV/Vis spectrophotometers<br />
are the industry standard for high<br />
performance, flexibility and convenience.<br />
Each model includes the same range<br />
of modular components and snap-in<br />
accessories to tackle a range of<br />
tough applications.<br />
LAMBDA 650<br />
The LAMBDA 650 is an upgradeable,<br />
flexible UV/Vis system at a cost-effective<br />
price. This system is for high performance<br />
measurements between 190 and 900 nm.<br />
Applications include color analysis of<br />
paints and textiles, turbid solutions,<br />
and enzyme kinetics in life science,<br />
biochemistry, and pharmaceutical<br />
laboratories. The LAMBDA 650 can be<br />
upgraded for higher sampling. A 150 mm<br />
integrating sphere is included for ASTM,<br />
CIE, and DIN measurements.<br />
LAMBDA 850<br />
The LAMBDA 850 is our highest<br />
performance UV/Vis system. Choose this<br />
model for ultra-high UV/Vis performance<br />
for wavelengths between 175 and 900 nm,<br />
for applications such as sun protection,<br />
reflectance properties of flat panel display<br />
screens, paint films, transmission and<br />
reflectance characterization of glass<br />
and solar cells.<br />
LAMBDA 950<br />
The LAMBDA 950 is our highest<br />
performance UV/Vis/NIR System. Choose<br />
this model for ultra-high UV/Vis/NIR<br />
performance for wavelengths up to<br />
3,300 nm, high precision measurements,<br />
and for applications such as highly<br />
reflective and anti-reflective coatings,<br />
color correction coatings, bandpass<br />
characteristics of UV, Vis, and NIR filters,<br />
and more.<br />
379
Accessories<br />
Fiber Optic and General Purpose Optical Bench Accessories<br />
Autosampler Supplies<br />
and Accessories for UV<br />
Please see pages 8-9 for our full selection of Sample Trays, Sample Vessels,<br />
Probes, Tubing, and Accessories for the AS93plus Autosampler.<br />
Fiber Optics Accessories<br />
Light Shield<br />
For use with Fiber Optic Dip Probe (N1016070).<br />
LAMBDA Model Part No. Each (€)<br />
All N1016074 437<br />
Probe Tip<br />
For use with Fiber Optic Dip Probe (N1016070).<br />
UV Visible Accessories<br />
Transfer-Optic for 1X/2X/3X/4X/Bio Part No. B0509546<br />
Transfer-Optic for Mono-Fibers<br />
Fiber optic transfer holder for LAMBDA spectrophotometers.<br />
Requires pair of Mono-Fibers 2x2 or 2x10 meters and/or<br />
optrode. Other optrodes available on request<br />
LAMBDA Model Part No. Each (€)<br />
1X/2X/3X/4X/Bio B0509546 2129<br />
650/850/950 L6020290 2505<br />
800/900 B2205302 4512<br />
Pair of Mono-Fibers<br />
2x2 meters each.<br />
Wavelength Part No. Each (€)<br />
250 to 900 nm (UV/Vis) B0196912 2895<br />
400 to 2400 nm (Vis/NIR) B0509591 2012<br />
Fiber Optic Dip Probe<br />
The Fiber Optic Dip Probe is a 15 mm, 316 grade stainless<br />
steel probe with a wavelength of 200-1100 nm. Requires<br />
but does not include, Transfer-Optic for Mono-Fibers,<br />
Light Shield (N1016074), and one of the following Probe<br />
Tips: Probe Tip, 2 mm pathlength (N1016073); Probe Tip,<br />
5 mm pathlength (N1016072); or Probe Tip, 10 mm<br />
pathlength (N1016071).<br />
LAMBDA Model Part No. Each (€)<br />
All N1016070 1675<br />
Pathlength Part No. Each (€)<br />
2 mm N1016073 556<br />
5 mm N1016072 616<br />
10 mm N1016071 682<br />
General Purpose Optical Bench Kits<br />
for the LAMBDA 6XX/8XX/9XX<br />
Sample Holder Mount Kit<br />
Two cantilever sample holders<br />
with magnetic bases.<br />
Variable Angle Transmittance Sample Holder Kit<br />
Holds samples at an accurately measured angle to the<br />
incident beam for measurement of<br />
transmittance. Samples can be up<br />
to 1 cm thick and up to 10 cm square.<br />
Part No.<br />
PELA1006<br />
Each (€)<br />
1579<br />
Optical Bench Kit<br />
Two magnetized mounted iris<br />
diaphragms on two optical<br />
rails with mounts.<br />
Short Focal Length Mirror Kit, Spot Incidence<br />
Kit consists of a short focal length (20 to 30 mm) concave<br />
mirror on an adjustable base with<br />
magnetic mounts to allow for small<br />
spot incidence of curved samples.<br />
Part No.<br />
PELA1013<br />
Each (€)<br />
975<br />
Beam Blocker Kit<br />
Optical black beam blocker on<br />
adjustable base with magnetic mounts.<br />
Fiber Optic Measurement Stage and Holder Kit<br />
Includes two fiber optic holders to<br />
allow for measurement of small<br />
diameter fibers and fixed apertures.<br />
Part No.<br />
Each (€)<br />
PELA1005 1208<br />
Part No.<br />
Each (€)<br />
PELA1008 2010<br />
Part No.<br />
Each (€)<br />
PELA1014 329<br />
Part No.<br />
Each (€)<br />
PELA1015 6100<br />
380
Accessories<br />
Integrating Sphere Accessories<br />
Biconical Accessory Small Spot Size (Praying Mantis) Part No. PELA1022<br />
Biconical Accessory Small Spot Size (Praying Mantis)<br />
For diffuse reflectance measurement with horizontal sample<br />
position for powders, pastes, and granulates. Provides a<br />
very small spot size.<br />
LAMBDA Model Wavelength Range Part No. Each (€)<br />
1X/2X/3X/4X/Bio 200 to 1100 nm C6950209 8700<br />
6XX/8XX/9XX 200 to 3300 nm PELA1022 11000<br />
Variable Angle Transmittance Sample Holder<br />
of Non-Scattering Samples<br />
Includes sample holder and manual rotary stage<br />
cinematically positioned in front of the sphere.<br />
LAMBDA Model Part No. Each (€)<br />
6XX/8XX/9XX PELA9042 2165<br />
Center Mounted Sample Holder, Clip Style<br />
Part No. PELA9039<br />
Center Mounted Sample Holder, Clip Style<br />
For 150 mm integrating spheres. Clip style for films<br />
and paper samples.<br />
LAMBDA Model Part No. Each (€)<br />
6XX/8XX/9XX PELA9039 3185<br />
Center Mounted Sample Holder, Jaw Style<br />
For 150 mm integrating spheres. Jaw style for solid<br />
samples like glasses, prisms, etc.<br />
LAMBDA Model Part No. Each (€)<br />
6XX/8XX/9XX PELA9038 3913<br />
Cell Holder for 150 mm Integrating Sphere<br />
For measurement in 1 cm cuvettes in transmission<br />
or reflectance mode.<br />
LAMBDA Model Part No. Each (€)<br />
6XX/8XX/9XX C6951019 185<br />
Small Spot Accessory Kit<br />
for 150 mm Integrating Sphere<br />
Lens kit for reducing beam size to the transmittance, to<br />
the center mount, and to the diffuse reflectance position.<br />
LAMBDA Model Part No. Each (€)<br />
6XX/8XX/9XX L6020211 9100<br />
Accessories UV Visible<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
381
Accessories<br />
Polarizer/Depolarizer Accessories<br />
Polarizer/Depolarizer and Accessories<br />
for the LAMBDA 6XX/8XX/9XX<br />
Common Beam Depolarizer<br />
for LAMBDA 6XX/8XX/9XX<br />
For measurements with depolarized light. Wavelength<br />
range: 190 to 2600 nm. Setup with stepper drive, controlled<br />
by UV WinLab TM software.<br />
Service installation required.<br />
Part No. Each (€)<br />
B0501282 3373<br />
Polarizer/Depolarizer Crystals<br />
for the LAMBDA 6XX/8XX/9XX<br />
High Performance Polarizer Crystal<br />
for LAMBDA 6XX/8XX/9XX Double Polarizer Drive<br />
High performance polarizer. One set to update the Double<br />
Polarizer Drive. For equal energy level in sample and<br />
reference beam, two Crystals are necessary.<br />
Wavelength range: 300 to 2600 nm. Part No. Each (€)<br />
B0505284 8100<br />
UV Visible Accessories<br />
Double Polarizer Drive Part No. B0505530<br />
Double Polarizer Drive for LAMBDA 6XX/8XX/9XX<br />
High performance double polarizer (depolarizer) driver for<br />
installation in the sample compartment. The polarization<br />
(depolarization) orientation can be fully automated,<br />
changed by a scan at a fixed wavelength or with a stepping<br />
mode. Resolution of 0.25° for scanning. The polarization<br />
(depolarization) orientation in the<br />
stepping mode can be changed at Part No. Each (€)<br />
up to 20 wavelength positions.<br />
B0505530 1106<br />
Requires, but does not include, one or two of the following<br />
polarization elements:<br />
Description Part No. Each (€)<br />
High Performance Polarizer Crystal B0505284 8100<br />
Film Polarizer B2205022 688<br />
Depolarizer Crystal B2205021 2931<br />
Glan-Taylor Polarizer Crystal N1010520 2285<br />
Film Polarizer for LAMBDA 6XX/8XX/9XX<br />
Double Polarizer Drive<br />
High performance film polarizer. One part to update the<br />
Double Polarizer Drive. For equal energy level in sample<br />
and reference beam, two Crystals are necessary. Wavelength<br />
range: 400 to 700 nm. Other wavelength<br />
ranges available on request.<br />
Part No. Each (€)<br />
B2205022 688<br />
Glan-Taylor Polarizer Crystal<br />
for LAMBDA 6XX/8XX/9XX Double Polarizer Drive<br />
Mounted 15 mm Glan-Taylor polarizer. For equal energy<br />
level in sample and reference beam,<br />
two Crystals are necessary. Wavelength<br />
range: 210 to 1000 nm.<br />
Part No.<br />
N1010520<br />
Each (€)<br />
2285<br />
Depolarizer Crystal for LAMBDA 6XX/8XX/9XX<br />
Double Polarizer Drive<br />
High performance depolarizer crystal for measurements in<br />
depolarized light in the sample compartment. One part to<br />
update the double polarizer drive. For equal energy level in<br />
sample and reference beam, two Crystals are necessary. The<br />
depolarizer crystals can be rotated at up to 20 wavelength<br />
points to get a wavelength<br />
independent depolarization.<br />
Part No. Each (€)<br />
Wavelength range: 190 to 2600 nm.<br />
B2205021 2931<br />
Sippers and Accessories<br />
Peristaltic Sipper “PESI”<br />
Sampling and purging time selectable from keyboard.<br />
For LAMBDA 25/35/45/10/20/40 no accessory PCB<br />
necessary. Requires, but does not include, accessory PCB<br />
for LAMBDA Bio 11, 12, and 14, (B0509681/B2190034) or<br />
accessory PCB for LAMBDA 18/19 (B0124984/B0116378).<br />
For LAMBDA 6XX/8XX/9XX, requires, but does not<br />
include, Installation Kit for LAMBDA 800/900 (B2500123)<br />
and Accessory PC Board for LAMBDA 800/900 (B2205116).<br />
Requires, but does not include, Flowcell<br />
of choice with screw connector.<br />
Part No.<br />
Each (€)<br />
B2190036 1256<br />
382
Accessories<br />
Sipper Accessories<br />
Sipper Cells<br />
Flow-Through Cell, 10 mm, with<br />
Two Screw Connectors<br />
10 mm pathlength, with two screw<br />
connectors, Quartz SUPRASIL ® ,<br />
160 μL cell volume.<br />
Part No. Each (€)<br />
B0631087 297<br />
Vacuum Sipper “VASI”<br />
Sampling and purging time selectable from keyboard.<br />
For LAMBDA 25/35/45/10/20/40 no accessory PCB<br />
necessary. Requires, but does not include, accessory PCB<br />
for LAMBDA Bio 11, 12 and 14 (B0509681/B2190034) or<br />
accessory PCB for LAMBDA 18/19 (B0124984/B0116378).<br />
Compatible with UV WinLab 2.8 or earlier only.<br />
For LAMBDA 6XX/8XX/9XX, requires, but does not<br />
include, Installation Kit for LAMBDA 800/900 (B2500123)<br />
and LAMBDA 800/900 Accessory PC Board (B2205116).<br />
Compatible with UV WinLab 3.0 or earlier only.<br />
Requires, but does not include, 110 V/60 Hz Pump Unit<br />
(B0505866) or 220 V/50 Hz Pump Unit (B0084183) and<br />
Flowcell of choice with screw connector.<br />
Description Part No. Each (€)<br />
Vacuum Sipper with Pinch Valve B2190037 1142<br />
Vacuum Sipper with Solenoid Valve B2190038 1675<br />
Pump Unit<br />
Vacuum pump with 1 L waste bottle. For use with sipper<br />
systems (or funnel cells).<br />
Power Requirement Part No. Each (€)<br />
120 V/60 Hz B0505866 831<br />
220 V/50 Hz B0084183 873<br />
Long Pathlength Flowcell, 50 mm,<br />
with Two Screw Connectors<br />
50 mm pathlength, with two screw<br />
connectors, Quartz, 370 μL<br />
cell volume.<br />
Micro Flowcell, 10 mm, with Nipple Connector<br />
10 mm pathlength, non-thermostatted,<br />
nipple connector, Quartz SUPRASIL,<br />
160 μL cell volume.<br />
Long Pathlength Micro Flowcell, 50 mm,<br />
with Nipple Connector<br />
50 mm pathlength, 4 mm circular<br />
chamber. Nipple connector, Quartz<br />
SUPRASIL, 600 μL cell volume.<br />
Sipper Tubing<br />
Tubing Kit for Peristaltic and Vacuum Sipper<br />
For Peristaltic Sipper “PESI”<br />
(B2190036), and Vacuum Sipper<br />
“VASI” with Pinch Valve (B2190037).<br />
Tubing Kit for Vacuum Sipper with Solenoid Valve<br />
For Vacuum Sipper “VASI” with<br />
Solenoid Valve (B2190038). For Micro<br />
Flowcells with screw connectors.<br />
Tygon Tubing for Peristaltic Pump (Purple/Purple)<br />
2.06 mm i.d. with a 0.80 mm<br />
wall thickness. (pkg. 12)<br />
Part No.<br />
Each (€)<br />
B0631088 659<br />
Part No.<br />
Each (€)<br />
B0191766 528<br />
Part No.<br />
Each (€)<br />
B0109944 869<br />
Part No.<br />
Each (€)<br />
B2500103 117<br />
Part No.<br />
Each (€)<br />
B0198023 117<br />
Part No.<br />
Each (€)<br />
B0199034 37<br />
Accessories UV Visible<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
383
Accessories<br />
Specular Reflectance<br />
Absolute Specular<br />
Reflectance Accessory<br />
Accessories for<br />
Specular Reflectance<br />
UV Visible Accessories<br />
VN Absolute Specular Reflectance Accessory Part No. N1016008<br />
VN Absolute Specular Reflectance Accessories<br />
for the LAMBDA 6XX/8XX/9XX Spectrophotometer<br />
The Absolute Specular Reflectance Accessory mounts in the<br />
standard sample compartment. It is used to produce absolute<br />
reflectance data on various types of surfaces. Both highly<br />
reflective and anti-reflective surfaces may be measured.<br />
When measuring a sample, only one light bounce from<br />
the sample surface is required. This provides the optimal<br />
s/n performance.<br />
Base Plate (N1016001) or the General Purpose Optical<br />
Bench Base Plate required. Use of Integrating Sphere<br />
Detector is recommended.<br />
Specifications:<br />
For measurements of absolute specular reflectance<br />
of filters, glasses, and mirrors<br />
Angle of Incidence: 8°, 15°, 30°, 45°, and 60°<br />
Typical Accuracy: Better than 1% reflectance when compared<br />
to a known commercially available standard (SRM 2003 etc.)<br />
Wavelength Range: 190 to 900 nm (LAMBDA 6XX),<br />
175 to 900 nm (LAMBDA 8XX), 175 to 3300 nm (LAMBDA 9XX)<br />
Sample Size: Minimum sample size ~ 2.5 cm<br />
Angle of Incidence Part No. Each (€)<br />
8° - Near Normal N1016008 5800<br />
15° N1016015 7200<br />
30° N1016030 7200<br />
45° N1016045 3394<br />
60° N1016060 3446<br />
Base Plate for VN Absolute Specular Reflectance<br />
Accessories for the LAMBDA 6XX/8XX/9XX<br />
Mother plate for the VN accessory suite.<br />
LAMBDA Model Part No. Each (€)<br />
6XX/8XX/9XX N1016001 2088<br />
Relative Specular Reflectance Accessory, 6° Part No. B0086703<br />
Relative Specular Reflectance Accessory, 6°<br />
For reflectance or thickness measurements.<br />
6° angle of light incidence.<br />
LAMBDA Model Part No. Each (€)<br />
All B0086703 2536<br />
Spare Standard Mirror<br />
For Relative Specular Reflectance Accessory, 6° (B0086703)<br />
and Variable Angle Reflectance Accessory (B0137314).<br />
This mirror is not calibrated.<br />
LAMBDA Model Part No. Each (€)<br />
All B0071519 159<br />
Powder Sample Holder Set<br />
For measurement of powder samples.<br />
LAMBDA Model Part No. Each (€)<br />
All PELA9040 682<br />
384
Accessories<br />
Thermostatting Accessories<br />
Routine Peltier Single Sample Accessory<br />
Peltier temperature controlled single cell holder for the<br />
sample position. Also included are a reference position<br />
cover, power supply, power cables, and User’s Guide.<br />
Selectable temperature range 20° to 45 °C. Requires the<br />
LAMBDA 25, 35, 45 Accessory Board (L6000500).<br />
LAMBDA Model Part No. Each (€)<br />
1X/2X/3X/4X/Bio B2000159 3148<br />
Routine Peltier Systems<br />
Routine Peltier System – Single Sample Accessory<br />
+ Single Reference Accessory<br />
Includes the Peltier Single Sample Accessory (B2000159)<br />
for the sample position and the Single Reference Accessory<br />
(B0510412) for the reference position. Also included are a<br />
reference position cover, power supply, power cables, and<br />
User’s Guide. Selectable temperature range 20° to 45 °C.<br />
Requires the LAMBDA 25, 35, 45 Accessory Board (L6000500).<br />
LAMBDA Model Part No. Each (€)<br />
1X/2X/3X/4X/Bio N1010565 3947<br />
Routine Peltier System – 9-Sample Position<br />
Accessory + Single Reference Accessory<br />
Includes the Peltier 9-Sample Position Accessory for<br />
the sample position and the Single Reference Accessory<br />
for the reference position. Also included are 5 beam<br />
masks, alignment gauge, reference position cover, sample<br />
compartment extension, power supply, cables, and User’s<br />
Guide. Selectable temperature range 20° to 45 °C. Must be<br />
service installed. Requires the LAMBDA 25, 35, 45<br />
Accessory Board (L6000500).<br />
LAMBDA Model Part No. Each (€)<br />
1X/2X/3X/4X/Bio N1010566 5400<br />
Routine Peltier 9-Sample Position Accessory<br />
Includes the Peltier 9 position cell changer, 5 beam masks,<br />
alignment gauge, reference position cover, sample compartment<br />
extension, power supply, power cables, and User’s Guide.<br />
Must be service installed. Selectable temperature range 20°<br />
to 45 °C. Requires the LAMBDA 25, 35, 45 Accessory<br />
Board (L6000500).<br />
LAMBDA Model Part No. Each (€)<br />
1X/2X/3X/4X/Bio B2000160 4555<br />
Routine Peltier Single Reference Accessory<br />
Peltier temperature controlled single cell holder for the<br />
reference position Also included are the power supply,<br />
power cables, and User’s Guide. Selectable temperature<br />
range 20° to 45 °C. Requires the LAMBDA 25, 35, 45<br />
Accessory Board (L6000500).<br />
LAMBDA Model Part No. Each (€)<br />
1X/2X/3X/4X/Bio B0510412 819<br />
9-Postion Cell Holder<br />
As included with the Peltier 9-Sample Position Accessory.<br />
Additional interchangeable cell holder for use with the<br />
9-position cell changer.<br />
LAMBDA Model Part No. Each (€)<br />
1X/2X/3X/4X/Bio B0510366 437<br />
Accessories UV Visible<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
385
Accessories<br />
Thermostatting Accessories<br />
Peltier Controlled Fluid Circulator (PCB-150)<br />
An external fluid circulator for use with all thermostatted<br />
cell holders enabling peltier effect temperature control.<br />
With both heating and cooling ability the circulator<br />
provides a temperature range of 20° to 60 °C with an<br />
accuracy of +/- 0.1 °C. Also included is a serial port<br />
and documentation to enable PC programming.<br />
LAMBDA Model Part No. Each (€)<br />
All N1015158 2840<br />
UV Visible Accessories<br />
Research Peltier<br />
System – 6 Position<br />
Part No. L6310011<br />
Research Peltier System<br />
Research Peltier System – Single Cell (PTP-1)<br />
For thermostatting of one rectangular cell in the sample<br />
beam. Temperature range 0° to 100 °C. Flexible programming<br />
of temperature ramps with up to 8 segments is possible.<br />
For thermostatting the reference cell holder, use Water<br />
Thermostatted Cell Holder (B0080819), not included.<br />
LAMBDA Model Part No. Each (€)<br />
All L6310010 3858<br />
Research Peltier System – 6 Position (PTP-6)<br />
For thermostatting of up to six rectangular cells in the sample<br />
beam, stirring possible. Temperature range 0° to 100 °C.<br />
Flexible programming of temperature ramps with up to<br />
8 segments is possible. Requires, but does not include,<br />
Automatic Linear Transport for LAMBDA 1X/2X/3X/4X/Bio<br />
(B2000186) or Linear Cell Programmer for LAMBDA<br />
6XX/8XX/9XX (B2205401).<br />
LAMBDA Model Part No. Each (€)<br />
All L6310011 6400<br />
Water Thermostatted Cell Holder<br />
A single cell holder with 3 mm fluid tubing connectors to<br />
enable fluid circulated temperature stabilization. Can be<br />
installed in the reference position with the PTP-1 and PTP-6<br />
to allow the reference sample to be temperature controlled.<br />
Requires, but does not include, a fluid circulator.<br />
LAMBDA Model Part No. Each (€)<br />
All B0080819 737<br />
Water Circulator, 220 V/50 Hz<br />
Electronic temperature control, continuously settable from<br />
20° to 65 °C, temperature stability +/- 0.2 °C, with precision<br />
thermometer and built-in cooling coils.<br />
LAMBDA Model Part No. Each (€)<br />
All B0080171 2143<br />
Water Circulator, 110 V/60 Hz<br />
Electronic temperature control, continuously settable from<br />
32° to 60 °C, temperature stability +/- 0.2 °C, with precision<br />
thermometer and built-in cooling coils.<br />
LAMBDA Model Part No. Each (€)<br />
All N9302736 1746<br />
Temperature Measurement Kit<br />
Probe for measuring the temperature within the cell.<br />
Includes glass cell. Requires the LAMBDA 25, 35, 45<br />
Accessory Board (L6000500).<br />
LAMBDA Model Part No. Each (€)<br />
1X/2X/3X/4X/Bio B0185227 472<br />
Magnetic Stirrer Accessory<br />
For 1-cell position. For single cell holders and cell changers.<br />
Power Requirements Part No. Each (€)<br />
110 V/60 Hz B0507355 778<br />
220 V/50 Hz B0510070 945<br />
Stirring Rods<br />
Set of 15 pieces for stirring in the cuvette. For use with<br />
Research Peltier System – 6 Position (PTP-6), (L6310011) and<br />
13-Cell Changer System (B0185210), and<br />
Magnetic Stirrer Accessory (B0507355). Part No. Each (€)<br />
B0187028 63<br />
386
Cells<br />
Cell Changers and Accessories<br />
Cell Changers for<br />
LAMBDA 1X/2X/3X/4X/Bio<br />
5+5 Cell Changer for LAMBDA 1X/2X/3X/4X/Bio<br />
Automatic linear 5+5 cell changer for long pathlength<br />
cells up to 50 mm. Includes: Automatic Linear Transport<br />
(B2000186), Reference Kit (B2000310), and two Long<br />
Pathlength 5-Cell Holders (B0089439).<br />
No accessory PCB required.<br />
Part No. Each (€)<br />
8+1 Cell Changer for LAMBDA 1X/2X/3X/4X/Bio<br />
Automatic water thermostattable automatic linear cell<br />
changer for eight samples and one reference. Includes:<br />
Automatic Linear Transport<br />
(B2000186), 8-Cell Holder<br />
Water Thermostattable<br />
(B2205411), and Water<br />
Thermostattable Reference<br />
Cell Holder (B2000201).<br />
No accessory PCB required.<br />
8+8 Cell Changer for LAMBDA 1X/2X/3X/4X/Bio<br />
13-Cell Changer System for LAMBDA<br />
1X/2X/3X/4X/Bio<br />
N1010569 3146<br />
Part No.<br />
Each (€)<br />
N1010567 2775<br />
Automatic water thermostattable automatic linear cell<br />
changer for eight samples and eight references. Includes:<br />
Automatic Linear Transport (B2000186), Reference Kit<br />
(B2000310), and two 8-Cell Holders<br />
(B2205411). No accessory PCB required. Part No. Each (€)<br />
N1010568 3266<br />
Includes cell changer and one carousel each for glass/quartz<br />
and plastic cuvettes. Accessory PCB (L6000500) required for<br />
LAMBDA 25/35/45, or PCB (B0509681)<br />
required for LAMBDA 10/20/40/Bio,<br />
but not included.<br />
Part No.<br />
B0185210<br />
Each (€)<br />
2966<br />
Manual Cell Changer for LAMBDA 1X/2X/3X/4X/Bio<br />
Base unit to be used with cell holder of choice. Includes<br />
Accessory Cover (B0094014). Requires, but does not<br />
include, Long Pathlength 5-Cell Holder<br />
(B0089439) or 8-Cell Holder, Water<br />
Thermostattable (B2500081).<br />
Part No.<br />
B2500080<br />
Each (€)<br />
945<br />
Automatic Linear Transport for LAMBDA<br />
1X/2X/3X/4X/Bio<br />
Automatic linear transport unit. Can be combined with<br />
8-Cell Holder, Water Thermostattable (B2205411), Long<br />
Pathlength 5-Cell Holders (B0089439), or Research Peltier<br />
System (L6310011). For reference position, Reference Kit<br />
(B2000310) and 5- or 8-Cell Holder recommended, but<br />
not included. Single Cell Reference<br />
Holder (B2000201) can be<br />
Part No. Each (€)<br />
used alternatively.<br />
B2000186 1711<br />
Reference Kit<br />
For Automatic Linear Transport (B2000186). For reference<br />
position to be used with 8-Cell Holder, Water Thermostattable<br />
(B2205411) or Long Pathlength<br />
5-Cell Holder (B0089439).<br />
Part No. Each (€)<br />
Gel-Scanner Linear Transport for Gels and Glasses<br />
for LAMBDA 1X/2X/3X/4X/Bio<br />
Complete Gel-Scanner accessory. Allows measurement<br />
of 100 mm gel cuvettes or glass samples up to 100 mm<br />
pathlength in continuous or random access mode.<br />
No accessory PCB required. For gel<br />
measurement, Gel Cell (B0107047)<br />
is required, but not included.<br />
Part No.<br />
B2000199<br />
Each (€)<br />
4019<br />
Gel Cell, Glass<br />
B2000310 359<br />
For gel measurements with Gel-Scanner Linear Transport<br />
(B2000199). Dimensions are 6 mm pathlength by 100 mm<br />
width by 10 mm height.<br />
Part No. Each<br />
(€)<br />
CP183700 251<br />
Cells UV Visible<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
387
Cells<br />
Cell Changers and Holders<br />
UV Visible Cells<br />
Cell Changers for LAMBDA 6XX/8XX/9XX<br />
9+9 Peltier Controlled<br />
Cell Programmer<br />
for LAMBDA<br />
6XX/8XX/9XX<br />
Spectrophotometers<br />
The accessory includes<br />
two sample trays with<br />
nine positions each. The following sample setup is possible:<br />
one reference cell and eight sample cells on either tray or<br />
nine cells on the sample tray and nine cells on the reference<br />
tray. For temperature control,<br />
Accessory PCB required (B2205116). Part No. Each (€)<br />
Temperature range 15° to 45 °C.<br />
B2205104 5500<br />
Linear Cell<br />
Programmer for<br />
LAMBDA 6XX/8XX/9XX<br />
UV/Vis/NIR<br />
Spectrophotometers<br />
Requires set of two cell<br />
holders of choice, either<br />
two Long Pathlength 5-Cell Holders (B0089439), or two 8-Cell<br />
Holders, Water Thermostattable (B2205411).<br />
Part No.<br />
Each (€)<br />
B2205401 3385<br />
Linear Transport<br />
and Gel-Scanner for<br />
LAMBDA 8XX/9XX<br />
Complete Gel-, Film-,<br />
and Filter-Scanner<br />
accessory for LAMBDA<br />
8XX/9XX. Allows<br />
measurement of 100 mm gel cuvettes or film and glass<br />
samples in continuous or random mode.<br />
Part No. Each (€)<br />
B2205420 3660<br />
Cell Holders<br />
To extend the range of samples you can analyze, we offer<br />
a wide range of sample cell holders.<br />
Standard Cell Holder<br />
The Standard Cell Holder<br />
is provided as standard<br />
equipment with your<br />
PerkinElmer LAMBDA Series<br />
instrument. A lifter (included)<br />
makes short cell removal<br />
easy. It accommodates a<br />
large selection of rectangular<br />
cells up to 10 mm pathlength. The Standard Cell Holder<br />
is adjustable both vertically and horizontally.<br />
Rectangular Long-Path<br />
Cell Holder for LAMBDA<br />
1X/2X/3X/4X/Bio<br />
The Rectangular Long-Path<br />
Cell Holder accepts cells with<br />
pathlengths from 10 to 100 mm.<br />
This optional cell holder is easy to<br />
install and has the same footprint<br />
as the Standard Cell Holder. It<br />
is designed for a precise fit and gives<br />
you maximum reproducibility.<br />
Part No. Each (€)<br />
Cylindrical Long-Path Cell Holder<br />
for LAMBDA 6XX/8XX/9XX<br />
Accommodates cylindrical cells with<br />
pathlengths up to 100 mm.<br />
Part No.<br />
Cylindrical Long-Path<br />
Cell Holder<br />
Each (€)<br />
B0505071 396<br />
B0080821 566<br />
The Cylindrical Long-Path<br />
Cell Holder accommodates<br />
cells with outside diameters<br />
from 22 to 30 mm. A versatile<br />
cell holder, it accepts cells<br />
with pathlengths up to<br />
100 mm. The spring loaded<br />
clamping arms provide a<br />
precise, reproducible fit and<br />
are easy to adjust.<br />
Part No.<br />
Each (€)<br />
C0550303 148<br />
Part No.<br />
Each (€)<br />
B0082539 264<br />
388
Cell Holders<br />
Solid Sample Holder<br />
Minimum sample size<br />
10 x 15 mm. Maximum<br />
sample thickness 5 mm.<br />
8-Cell Holder, Water Thermostattable<br />
Cells<br />
Cell Holders<br />
For Automatic Linear Transport for LAMBDA 1X/2X/3X/<br />
4X/Bio (B2000186) or LAMBDA 800/900 (B2205401) in<br />
sample or reference position.<br />
Accommodates up to eight<br />
10 mm cells.<br />
Part No.<br />
B2205411<br />
Each (€)<br />
544<br />
Part No. Each (€)<br />
B0080822 419<br />
Single-Cell Reference Holder<br />
For Automatic Linear Transport<br />
(B2000186). For one cell with up<br />
to 10 mm pathlength.<br />
Part No. Each (€)<br />
B2000201 359<br />
Long Pathlength 5-Cell Holder<br />
Test Tube Holder<br />
This holder accommodates<br />
test tubes from 11 to<br />
17 mm diameter.<br />
Variable Angle<br />
Sample Holder<br />
Part No.<br />
0° to 60° for sample position<br />
for measurement in transmission<br />
of filter glasses and other<br />
transparent samples. Minimum<br />
sample size is 30 x 40 mm.<br />
Part No.<br />
Each (€)<br />
B0500952 434<br />
Each (€)<br />
B0152471 1603<br />
For Automatic Linear Transport for LAMBDA 1X/2X/3X/<br />
4X/Bio (B2000186) or LAMBDA 800/900 (B2205401) in<br />
sample or reference position.<br />
Accommodates five cells<br />
of up to 50 mm pathlength.<br />
Part No.<br />
B0089439<br />
Each (€)<br />
472<br />
Glass/Quartz Cuvette Cell<br />
Holder/Carousel for 13-Cell Changer<br />
For use with the 13-Cell<br />
Changer (B1085210).<br />
Plastic Cuvette Cell Holder/Carousel<br />
for 13-Cell Changer<br />
For use with the 13-Cell<br />
Changer (B1085210).<br />
8-Cell Holder, Water Thermostattable for Manual<br />
Cell Changer for LAMBDA 1X/2X/3X/4X/Bio<br />
For Manual Cell Changer (B2500080).<br />
Accepts eight cells of up to<br />
10 mm pathlength.<br />
Long Pathlength Reference Cell Holder,<br />
Non-Thermostatted for LAMBDA 1X/2X/3X/4X/Bio<br />
For Manual Cell Changer (B2500080).<br />
Reference Cell Holder, Water Thermostattable<br />
for LAMBDA 1X/2X/3X/4X/Bio<br />
For Manual Cell Changer (B2500080).<br />
Part No.<br />
Part No.<br />
Each (€)<br />
B0193768 297<br />
Part No.<br />
Each (€)<br />
B2500081 664<br />
Part No.<br />
Each (€)<br />
B2500082 324<br />
Part No.<br />
Each (€)<br />
B0185163 323<br />
Each (€)<br />
B2500083 329<br />
Cells UV Visible<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
389
Cells<br />
Cells for Spectroscopy<br />
High Quality,<br />
Precision Cells<br />
Make Full Use of the Accuracy and<br />
Sensitivity of Your Optical Instrument<br />
No matter what type of cells your application requires –<br />
rectangular or cylindrical, standard or short path, micro,<br />
semi-micro, or flowcells – choosing only high quality,<br />
precision cells allows you to make full use of the<br />
accuracy and sensitivity of your optical instrument.<br />
PerkinElmer cells ensure top optical performance, with<br />
high cell transmission and accurate pathlength. The cell<br />
windows are fused to the bodies by a special process<br />
which avoids deformation of the windows. This assures<br />
that the full width of the cell is usable and the finished<br />
cell dimensions are maintained.<br />
PerkinElmer Spectroscopy Cells are available in a wide variety of sizes and types.<br />
Our cells are manufactured from various<br />
types of glass. We offer three basic<br />
materials, Special Optical Glass,<br />
SUPRASIL ® UV Quartz and SUPRASIL<br />
300 NIR Quartz in all the common sizes<br />
and types. The most important criterion<br />
for the choice of a particular type of glass<br />
is the spectral range for which the cell is<br />
intended. Color logos are fused onto each<br />
PerkinElmer cell, thus indicating the<br />
spectral range over which the cell can<br />
be used.<br />
Special Optical Glass<br />
Indicates that SCHOTT type UK 5 is<br />
used for cells referred to in the catalog<br />
as manufactured from “Special Optical<br />
Glass”. This crown glass is made from<br />
exceptionally pure raw materials, which<br />
gives an improved transmission in the<br />
near ultraviolet range. An empty cell<br />
will give a transmission of more than<br />
80% over a spectral range of between<br />
320 and 2500 nm.<br />
SUPRASIL UV Quartz<br />
Indicates that quartz of the highest<br />
purity and homogeneity has been used<br />
for the window. Because it is produced<br />
from a silicon compound, it is also<br />
called synthetic quartz. SUPRASIL<br />
gives transmission values of more than<br />
80% over a spectral range of between<br />
200 and 2500 nm for an empty cell.<br />
SUPRASIL 300 NIR Quartz<br />
Denotes a synthetic quartz that is free<br />
from OH absorption. Therefore it is<br />
suitable for applications in the near<br />
infrared range up to approximately<br />
4000 nm. SUPRASIL 300 gives a<br />
transmission of more than 80% over<br />
a spectral range of between 200 and<br />
3500 nm for an empty cell.<br />
390
Cells<br />
Cylindrical and Flow-Through Cells for Spectroscopy<br />
Cylindrical Cells – Macro with PTFE Stopper<br />
Cylindrical cells are used with spectrophotometers that have a larger, circular light beam. Each cell has an outside<br />
diameter of 22 mm and an inside diameter of 19 mm. Each package contains one cell and two windows.<br />
Lightpath Outside Cell<br />
Material mm Depth mm Volume Remarks Part No. Each (€)<br />
NIR Quartz 10 12.5 2.8 mL neck Ø 6 mm taper 1:10 B0631099 97<br />
SUPRASIL ® 300 20 22.5 5.6 mL neck NS 7 B0631100 97<br />
50 52.5 14.0 mL 2 necks NS 7 B0631101 129<br />
100 102.5 28.0 mL 2 necks NS 7 B0631102 143<br />
Quartz SUPRASIL 10 12.5 2.8 mL neck Ø 6 mm taper 1:10 B0631095 81<br />
20 22.5 5.6 mL neck NS 7 B0631096 85<br />
50 52.5 14.0 mL 2 necks NS 7 B0631097 113<br />
100 102.5 28.0 mL 2 necks NS 7 B0631098 127<br />
Special Optical Glass 10 12.5 2.8 mL neck Ø 6 mm taper 1:10 B0631091 53<br />
20 22.5 5.6 mL neck NS 7 B0631092 55<br />
50 52.5 14.0 mL 2 necks NS 7 B0631093 74<br />
100 102.5 28.0 mL 2 necks NS 7 B0631094 78<br />
Flow-through Cells<br />
NIR Quartz SUPRASIL Cylindrical<br />
Cells Macro with PTFE Stopper,<br />
10 mm Part No. B0631099<br />
Flow-through cells are used for measuring samples with continuous flow or with Sippers where individual samples are<br />
aspirated into the cell. All cells have center heights of 15 mm. Each package contains one cell with two clear windows. The<br />
cells listed below are Compact with two screw connectors, M6 x1 and 500 mm length FEP tubing - 1.9 mm o.d., 1.1 mm i.d.<br />
Lightpath Center Outside Dim. Aperture Cell<br />
Material mm Height mm H x W x D mm Volume Part No. Each (€)<br />
Quartz SUPRASIL 1 15 35 x 12.5 x 12.5 17.5 x 3.5 62 μL B0631085 506<br />
Quartz SUPRASIL 10 15 35 x 12.5 x 12.5 11 x 3.5 390 μL B0631084 268<br />
Quartz SUPRASIL 10 15 35 x 12.5 x 12.5 8 x 2 160 μL B0631087 297<br />
Quartz SUPRASIL 10 15 35 x 12.5 x 12.5 11 x 2.5 300 μL B0631150 583<br />
Quartz SUPRASIL 10 15 35 x 12.5 x 12.5 Ø 3 80 μL B0631089 278<br />
Quartz SUPRASIL 50 15 45 x 12.5 x 52.5 Ø 3 370 μL B0631088 659<br />
Quartz SUPRASIL 10 15 35 x 12.5 x 12.5 Ø 2 30 μL B0631090 274<br />
Quartz SUPRASIL (FIAS) 10 15 35 x 12.5 x 12.5 Ø 1.5 18 μL B0631151 529<br />
Quartz SUPRASIL (FIAS) 10 15 35 x 12.5 x 12.5 Ø 1 8 μL B0631152 308<br />
Lids and Stoppers<br />
Description Lightpath mm Part No. Each (€)<br />
Glass Covering Plate 1 B0631144 3<br />
PTFE Fitted Lid 5 B0631145 4<br />
PTFE Fitted Lid 10 B0631129 2<br />
PTFE Fitted Lid 20 B0631146 3<br />
PTFE Fitted Lid 50 B0631147 4<br />
Glass Fitted Lid 100 B0631148 15<br />
PTFE Stopper with NS 7 Fitting B0631128 3<br />
PTFE Stopper with Fitting Ø 6, taper 1:10 B0631149 3<br />
Replacement Tubing<br />
Description Part No. Each (€)<br />
FEP-Replacement Tubing with one short screw fitting, 500 mm long B0631130 25<br />
FEP-Replacement Tubing with one long screw fitting, 500 mm long B0631131 28<br />
Sipper Tubing to Cuvette (in) B2500129 75<br />
Sipper Tubing to Cuvette (out) B2500127 23<br />
FEP Tubing – Short Fitting<br />
Part No. B0631130<br />
FEP Tubing – Long Fitting<br />
Part No. B0631131<br />
Cells UV Visible<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
391
Cells<br />
Standard Cells for Spectroscopy<br />
Macro with PTFE Lid<br />
Standard rectangular Macro cells are the most common type of spectroscopy cell and are used for<br />
routine UV/VIS analysis. Each cell has a standard inside width of 9.5 mm and a base thickness<br />
of 1.5 mm. All Macro cells contain two clear windows.<br />
Lightpath Outside Dim. Cell<br />
Material mm H x W x D mm Volume Qty. Part No. Each (€)<br />
UV Visible Cells<br />
Special Optical Glass Macro<br />
with PTFE Lid, 10 mm<br />
Part No. B0631003<br />
NIR Quartz Macro<br />
with PTFE Stopper, 10 mm<br />
Part No. B0631033<br />
NIR Quartz SUPRASIL ® 300 1* 45 x 12.5 x 3.5 350 μL 2 B0631013 327<br />
5 45 x 12.5 x 7.5 1.75 mL 2 B0631014 177<br />
10 45 x 12.5 x 12.5 3.5 mL 2 B0631015 160<br />
20 45 x 12.5 x 22.5 7.0 mL 2 B0631016 332<br />
50 45 x 12.5 x 52.5 17.5 mL 1 B0631017 218<br />
100 45 x 12.5 x 102.5 35.0 mL 1 B0631018 200<br />
Optical Glass 10 45 x 12.5 x 12.5 3.5 mL 4 B0631134 120<br />
360-2500 nm without lid<br />
Quartz SUPRASIL 1* 45 x 12.5 x 3.5 350 μL 2 B0631007 150<br />
5 45 x 12.5 x 7.5 1.75 mL 2 B0631008 116<br />
10 45 x 12.5 x 12.5 3.5 mL 2 B0631009 111<br />
20 45 x 12.5 x 22.5 7.0 mL 2 B0631010 147<br />
50 45 x 12.5 x 52.5 17.5 mL 1 B0631011 118<br />
100 45 x 12.5 x 102.5 35.0 mL 1 B0631012 184<br />
Special Optical Glass 1* 45 x 12.5 x 3.5 350 μL 2 B0631001 84<br />
5 45 x 12.5 x 7.5 1.75 mL 2 B0631002 65<br />
10 45 x 12.5 x 12.5 3.5 mL 2 B0631003 54<br />
20 45 x 12.5 x 22.5 7.0 mL 2 B0631004 81<br />
50 45 x 12.5 x 52.5 17.5 mL 1 B0631005 62<br />
* Glass lid<br />
Macro with PTFE Stopper<br />
100 45 x 12.5 x 102.5 35.0 mL 1 B0631006 108<br />
Lightpath Outside Dim. Cell<br />
Material mm H x W x D mm Volume Qty. Part No. Each (€)<br />
NIR Quartz SUPRASIL 300 1 52 x 12.5 x 3.5 350 μL 2 B0631031 399<br />
5 46 x 12.5 x 7.5 1.75 mL 2 B0631032 356<br />
10 46 x 12.5 x 12.5 3.5 mL 2 B0631033 179<br />
20 46 x 12.5 x 22.5 7.0 mL 2 B0631034 200<br />
50 46 x 12.5 x 52.5 17.5 mL 1 B0631035 250<br />
100 46 x 12.5 x 102.5 35.0 mL 1 B0631036 467<br />
Quartz SUPRASIL 1 52 x 12.5 x 3.5 350 μL 2 B0631025 217<br />
5 46 x 12.5 x 7.5 1.75 mL 2 B0631026 159<br />
10 46 x 12.5 x 12.5 3.5 mL 2 B0631027 157<br />
20 46 x 12.5 x 22.5 7.0 mL 2 B0631028 351<br />
50 46 x 12.5 x 52.5 17.5 mL 1 B0631029 179<br />
100 46 x 12.5 x 102.5 35.0 mL 1 B0631030 327<br />
Special Optical Glass 1 48 x 12.5 x 3.5 350 μL 2 B0631019 170<br />
5 46 x 12.5 x 7.5 1.75 mL 2 B0631020 216<br />
10 46 x 12.5 x 12.5 3.5 mL 2 B0631021 100<br />
50 46 x 12.5 x 52.5 17.5 mL 1 B0631023 147<br />
392
Cells<br />
Standard Cells for Spectroscopy<br />
Micro with PTFE Lid<br />
Micro cells have the same outside dimension as the Macro cells but the cell walls have been thickened,<br />
limiting the interior sample chamber width to 2 mm. This reduces the sample requirements by 80%.<br />
Each Micro cell has a standard light path of 10 mm and each package contains two cells with two<br />
clear windows each. All Micro cells listed have black sidewalls and base.<br />
Outside Dim. Base Cell<br />
Material H x W x D mm Thickness mm Volume Part No. Each (€)<br />
Quartz SUPRASIL ® 45 x 12.5 x 12.5 3.2 700 μL B0631071 290<br />
Special Optical Glass 45 x 12.5 x 12.5 3.2 700 μL B0631070 97<br />
Quartz SUPRASIL Micro<br />
with PTFE Lid 10 mm<br />
Part No. B0631071<br />
Micro with PTFE Stopper<br />
Outside Dim. Base Cell<br />
Material H x W x D mm Thickness mm Volume Part No. Each (€)<br />
NIR Quartz SUPRASIL 300 40 x 12.5 x 12.5 1.5 400 μL B0631078 709<br />
Quartz SUPRASIL 40 x 12.5 x 12.5 1.5 400 μL B0631077 382<br />
Special Optical Glass 40 x 12.5 x 12.5 1.5 400 μL B0631076 190<br />
Semi-micro with PTFE Lid – Black<br />
Semi-micro cells have the same outside dimension as the Macro cells but the cell walls have been<br />
thickened slightly, limiting the interior sample chamber width to 4 mm. This reduces the sample<br />
requirements by 60%. Each cell has a base thickness of 3.2 mm and each package contains two cells<br />
with two clear windows each.<br />
Lightpath Outside Dim. Cell<br />
Material mm H x W x D mm Volume Part No. Each (€)<br />
NIR Quartz SUPRASIL 300 5 45 x 12.5 x 7.5 700 μL B0631050 451<br />
10 45 x 12.5 x 12.5 1.4 mL B0631051 451<br />
Quartz SUPRASIL 5 45 x 12.5 x 7.5 700 μL B0631048 329<br />
10 45 x 12.5 x 12.5 1.4 mL B0631049 331<br />
Special Optical Glass 5 45 x 12.5 x 7.5 700 μL B0631046 137<br />
Semi-micro with PTFE Lid – Clear<br />
10 45 x 12.5 x 12.5 1.4 mL B0631047 95<br />
Lightpath Outside Dim. Cell<br />
Material mm H x W x D mm Volume Part No. Each (€)<br />
NIR Quartz SUPRASIL 300 20 45 x 12.5 x 22.5 2.8 mL B0631045 422<br />
Quartz SUPRASIL 20 45 x 12.5 x 22.5 2.8 mL B0631042 182<br />
Special Optical Glass 20 45 x 12.5 x 22.5 2.8 mL B0631039 143<br />
Quartz SUPRASIL Micro<br />
with PTFE Stopper 10 mm<br />
Part No. B0631077<br />
Quartz SUPRASIL Semimicro<br />
with PTFE Lid 10 mm<br />
Part No. B0631049<br />
Cells UV Visible<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
393
Cells<br />
Standard Cells for Spectroscopy<br />
Semi-micro with PTFE Stopper – Black<br />
Lightpath Outside Dim. Cell<br />
Material mm H x W x D mm Volume Part No. Each (€)<br />
NIR Quartz SUPRASIL ® 300 5 46 x 12.5 x 7.5 700 μL B0631065 489<br />
10 46 x 12.5 x 12.5 1.4 mL B0631066 489<br />
Quartz SUPRASIL 10 46 x 12.5 x 12.5 1.4 mL B0631064 580<br />
Special Optical Glass 5 46 x 12.5 x 7.5 700 μL B0631061 214<br />
Quartz SUPRASIL<br />
Semi-micro with PTFE<br />
Stopper 10 mm<br />
Part No. B0631064<br />
Semi-micro with PTFE Stopper – Clear<br />
Lightpath Outside Dim. Cell<br />
Material mm H x W x D mm Volume Part No. Each (€)<br />
UV Visible Cells<br />
Quartz SUPRASIL<br />
Ultra-micro with Pipette<br />
Tips 0.1 mm<br />
Part No. B0631082<br />
NIR Quartz SUPRASIL 300 20 46 x 12.5 x 22.5 2.8 mL B0631060 385<br />
Quartz SUPRASIL 20 46 x 12.5 x 22.5 2.8 mL B0631057 474<br />
Ultra-micro with PTFE Lid<br />
Ultra-micro cells use a narrower sample chamber, raising it directly into the center of the light path<br />
and masking it with black quartz. This design optimizes the use of smaller sample volumes. All<br />
Ultra-micro cells contain one cell and two clear windows.<br />
Lightpath Center Outside Dim. Aperture Chamber Filling<br />
Material mm Height mm H x W x D mm mm Vol. Vol. Part No. Each (€)<br />
Quartz SUPRASIL 10 15 45 x 12.5 x 12.5 2 x 1.5 30 μL 50 μL B0631079 206<br />
Ultra-micro with Pipette Tips<br />
Ultra-micro cells with Pipette Tips are available in Quartz SUPRASIL with center heights of 15 mm.<br />
Each package contains one cell with two clear windows.<br />
Lightpath Outside Dim. Aperture Chamber Filling<br />
Material mm H x W x D mm mm Vol. Vol. Part No. Each (€)<br />
Quartz SUPRASIL 0.1 40 x 12.5 x 12.5 1 x 5 0.5 μL 2 μL B0631082 420<br />
1 40 x 12.5 x 12.5 1 x 5 5 μL 10 μL B0631083 394<br />
5 45 x 12.5 x 12.5 Ø 0.8 2.5 μL 5 μL B0631080 385<br />
10 40 x 12.5 x 12.5 Ø 0.8 5 μL 10 μL B0631081 361<br />
394
Consumables and Supplies<br />
Calibration Reference Materials<br />
Secondary Reference Materials<br />
PerkinElmer reference materials speed calibration verification<br />
of UV/Vis and UV/Vis/NIR Spectrophotometers,* providing<br />
laboratory managers with the evidence they need to pass<br />
the strictest quality audit.<br />
A comprehensive range of certified traceable filters and<br />
sealed cuvettes fit into the standard instrument cuvette<br />
holder allowing users to generate simple protocols to verify<br />
ordinate and abscissa accuracy, stray light radiation, and<br />
spectral resolution. There is also a range of color and<br />
reflectance materials specifically designed for the popular<br />
LAMBDA 9/18/19/8XX/9XX Spectrophotometers.<br />
All reference materials are certified traceable to NIST<br />
primary reference material and supplied with a calibration<br />
certificate detailing the calibration method and results.<br />
A USA-based calibration laboratory ensures a reliable<br />
two-week turnaround service for periodical recalibrations,<br />
allowing laboratories to maintain the requirements of their<br />
calibration SOPs.<br />
Key features:<br />
Comprehensive range of materials<br />
Traceable to NIST<br />
Immediate availability<br />
Rapid recalibration service<br />
* Not diode array spectrometers<br />
Photometric and Wavelength Accuracy<br />
Reference Material Set<br />
Set of reference materials to verify the ordinate and<br />
abscissa (wavelength) accuracy of UV/Vis and UV/Vis/NIR<br />
Spectrophotometers. The set comprises four glass filters<br />
mounted in precision aluminum spring mounts. They are<br />
designed for use with the standard 10 mm cuvette holders<br />
of most UV/Vis and UV/Vis/NIR Spectrophotometers. The<br />
set is provided in a robust aluminum container. There are<br />
three neutral density glass filters for checking the ordinate<br />
accuracy and a holmium oxide glass filter for checking the<br />
wavelength accuracy of a spectrometer. Each filter has<br />
an identification number. The ordinate and abscissa values<br />
of each filter are quoted in the accompanying Certificate<br />
of Calibration. NG nominal 10%,<br />
20%, 50%/holmium oxide filter.<br />
Part No. Each (€)<br />
B0507805 1671<br />
Stray Light Solutions Reference Material Set<br />
Set comprising four solutions in sealed cells – one reference<br />
solution and three test solutions. The cells are designed for<br />
use with the standard 10 mm cuvette holders of most<br />
UV/Vis and UV/Vis/NIR Spectrophotometers. The test<br />
solutions comprising sodium iodide, sodium nitrite, and<br />
potassium chloride, act as a cut-off filter with a very precise<br />
wavelength. The set is provided in a robust aluminum<br />
container with a Certificate of<br />
Calibration. Sodium iodide, sodium Part No. Each (€)<br />
nitrite, potassium chloride, and water. B2500099 2166<br />
Pharmacopoeia Solutions Reference Material Set<br />
Set of sealed cells to verify calibration in accordance with<br />
Pharmacopoeia monographs.<br />
Ordinate (photometric) accuracy; potassium dichromate<br />
Abscissa (wavelength) accuracy; holmium perchlorate<br />
Level of stray radiation; potassium chloride<br />
Resolution; toluene in hexane<br />
Set comprising six solutions in sealed cells – two reference<br />
solutions and four test solutions. The cells are designed for<br />
use with the standard 10 mm cuvette holders of most UV/Vis<br />
and UV/Vis/NIR Spectrophotometers. The set is provided<br />
in two robust aluminum containers with a Certificate of<br />
Calibration. Potassium dichromate/potassium chloride,<br />
holmium perchlorate, and toluene.<br />
Part No. Each (€)<br />
Photometric and Wavelength Accuracy<br />
Reference Material Set Part No. B0507805<br />
B2500100 3903<br />
Consumables and Supplies UV Visible<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
395
Consumables and Supplies<br />
Calibration Reference Materials<br />
UV Visible Consumables and Supplies<br />
Spectralon ® UV/Vis/NIR Diffuse<br />
Reflectance Reference Material<br />
For use with LAMBDA 9/18/19/8XX/9XX<br />
150 mm integrating spheres<br />
Durable, chemically inert<br />
High reflectance values – 95 to 99%<br />
Washable<br />
Direct traceability to the National Institute<br />
of Standards and Technology (NIST)<br />
Spectralon diffuse reflectance standard sets consist of a<br />
diffuse white standard and a selection of diffuse gray<br />
reference material. Each standard in the set is supplied<br />
with complete diffuse reflectance data from 250 to 2500 nm,<br />
and is mounted in an anodized aluminum frame. The set is<br />
packed in an airtight storage case.<br />
Calibrated Diffuse Reflectance Reference<br />
Materials, Set of Four (1.25")<br />
Reflectance factors:<br />
99%, 75%, 50%, and 2%.<br />
Calibrated Diffuse Reflectance Reference<br />
Materials, Set of Eight (1.25")<br />
Reflectance factors: 99%, 80%,<br />
60%, 40%, 20%, 10%, 5%, and 2%.<br />
Calibrated Diffuse Reflectance Reference<br />
Materials, Set of Eight (2")<br />
Reflectance factors: 99%, 80%,<br />
60%, 40%, 20%, 10%, 5%, and 2%.<br />
Spectralon Diffuse<br />
Color Reference Material<br />
For use with LAMBDA 9/18/19/8XX/9XX<br />
150 mm integrating spheres<br />
Durable, chemically inert<br />
Highly diffuse<br />
Consistent reflectance<br />
Non-thermochromic<br />
Part No.<br />
Each (€)<br />
PELA9010 1242<br />
Part No.<br />
Each (€)<br />
PELA9012 3696<br />
Part No.<br />
Each (€)<br />
PELA9013 2739<br />
These durable, waterproof reference materials can be washed<br />
and easily machined without loss of color or surface texture.<br />
They are non-thermochromic, so there is no need to control<br />
laboratory temperature. As in the Diffuse Reflectance Reference<br />
Material Set, reference materials are supplied with data from<br />
250 to 2500 nm, mounted in anodized aluminum frames,<br />
and packed in an airtight case.<br />
Calibrated Diffuse Color Reference<br />
Materials, Set of Four (2")<br />
Set includes one each: red, green,<br />
blue, and yellow standard.<br />
Calibrated Diffuse Color and Neutral Reference<br />
Materials, Set of Eight (2")<br />
Set includes one each: red, green, blue, yellow, and four<br />
diffuse reflectance reference<br />
materials: 99%, 75%, 50%, and 2%. Part No. Each (€)<br />
Calibrated Diffuse Color Reference<br />
Materials,Set of Eight (2")<br />
Set includes one each: red, green, blue,<br />
yellow, orange, purple, cyan, and violet.<br />
Miscellaneous Calibration Materials<br />
Disposable Reference Mirror for<br />
Reflectance Spectroscopy<br />
This mirror is necessary to check the accuracy of absolute<br />
and to correct the spectra of non-absolute specular reflectance<br />
accessories. The mirror is a secondary standard and is<br />
calibrated according to GLP regulations,<br />
wavelength range 250 to 2500 nm. Part No. Each (€)<br />
Recalibration Reference Material<br />
To guarantee the integrity of the reference materials, you<br />
should have them recalibrated at periodic intervals. The<br />
recommended recalibration frequency is shown on the<br />
enclosed Certificate of Calibration. PerkinElmer will<br />
perform recalibration.<br />
Quantity Part No. Each (€)<br />
Set N1010539 938<br />
Single N1010540 263<br />
Spectralon Calibrated White Plate<br />
Size Part No. Each (€)<br />
1.25" PELA9057 688<br />
2.00" PELA9058 813<br />
Spectralon Calibrated Diffuse Reflectance<br />
Reference Material Set, Color<br />
Calibrated Spectralon color<br />
reference materials, set of four,<br />
and approximately 5 cm diameter.<br />
Part No.<br />
Each (€)<br />
PELA9018 1854<br />
PELA9020 4928<br />
Part No.<br />
Each (€)<br />
PELA9021 2767<br />
N1010504 1232<br />
Part No.<br />
Each (€)<br />
PELA9019 1854<br />
396
Consumables and Supplies<br />
Source Lamps<br />
Deuterium and Tungsten<br />
Source Lamps<br />
For optimum instrument performance, always use original<br />
replacement sources from PerkinElmer.<br />
Our extensive quality control and inspection process<br />
demands the very best quality sources. This guarantees<br />
top performance and maximum stability from your<br />
UV/Vis Spectrophotometer.<br />
Installation of a new lamp by a PerkinElmer Service Engineer<br />
is recommended for proper lamp alignment. Optimum<br />
performance is achieved when the lamp is correctly aligned.<br />
Eye protection is required when viewing deuterium or<br />
tungsten lamps when lit.<br />
Deuterium Lamp<br />
Part No. B0160917<br />
Tungsten Lamp<br />
Part No. B0114620<br />
Deuterium Lamps for LAMBDA Spectrophotometers<br />
LAMBDA Model Part No. Each (€)<br />
For LAMBDA 1/3 C0550505 610<br />
For LAMBDA 1X/2X/3X/4X/5X/5XX/Bio/6XX/8XX/9XX B0160917 579<br />
For LAMBDA 4/6 C6880055 676<br />
Tungsten Lamps for LAMBDA Spectrophotometers<br />
LAMBDA Model Part No. Each (€)<br />
For LAMBDA 1/3* C0550500 69<br />
For LAMBDA 1X/2X/3X/4X/Bio/6XX/8XX/9XX B0114620 98<br />
For LAMBDA 4/6* C6880054 97<br />
For 5X/5XX B0091906 120<br />
* Prefocused and prealigned<br />
Consumables and Supplies UV Visible<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
397
Software<br />
UV/Vis Application and Operating System Software<br />
UV Visible Software<br />
Advanced Applications Software<br />
PerkinElmer offers a variety of Advanced Application Software<br />
packages for use with your UV/Vis system. All programs:<br />
Include Results Database software (L6100050)<br />
Are validated under Windows 2000 and XP<br />
Require UV Winlab 2.85 or later for operation with<br />
the LAMBDA 25, 35, and 45<br />
Require UV Winlab 3.0 or later for operation with<br />
the LAMBDA 6XX/8XX/9XX<br />
Architectural Glass Software<br />
Software to enable the reflectance and transmittance<br />
properties of thin-film coatings applied to architectural glass<br />
to be evaluated. Included are ISO, DIN, and ASTM methods<br />
for light, solar, and UV, UVA, and UVB and normal, double,<br />
and triple glazing.<br />
LAMBDA Model WinLab Version Part No. Each (€)<br />
25/35/45/6XX/8XX/9XX 3.0 or earlier L6100047 938<br />
6XX/8XX/9XX 5.0 L6100116 938<br />
Color Methods Software<br />
A software package to calculate color indices for liquids,<br />
and clear and opaque solids. Compliant with all the major<br />
CIE, ASTM, DIN, and ISO methodologies, the software<br />
includes predefined illuminants, observers, and calculations<br />
required by the above along with easy-to-use graphical<br />
representation of results.<br />
LAMBDA Model WinLab Version Part No. Each (€)<br />
25/35/45/6XX/8XX/9XX 3.0 or earlier L6100046 1564<br />
6XX/8XX/9XX 5.0 L6100114 1564<br />
Filter Testing Software<br />
A dedicated software package to evaluate transmission<br />
characteristics of optical thin-film coatings for bandpass<br />
and non-bandpass filters.<br />
LAMBDA Model WinLab Version Part No. Each (€)<br />
25/35/45/6XX/8XX/9XX 3.0 or earlier L6100049 688<br />
6XX/8XX/9XX 5.0 L6100115 688<br />
Protection Glass Software<br />
Software offering industry standard calculations required<br />
for personal and industrial eye protection. Included are<br />
luminous, visible, UV, and near-IR transmittance calculations<br />
along with shade number and relative visual attenuation.<br />
LAMBDA Model WinLab Version Part No. Each (€)<br />
25/35/45/6XX/8XX/9XX 3.0 or earlier L6100048 938<br />
6XX/8XX/9XX 5.0 L6100117 938<br />
UV WinLab<br />
UV WinLab v5 Upgrade<br />
UV WinLab v5 is designed to simplify and speed the<br />
analysis performed on the LAMBDA family of instruments<br />
by mimicking the QA workflow. The ability to pre-define<br />
and lock methods ensures that the analyst is presented with<br />
only the information needed to perform the analysis.<br />
Using the latest database technology data retrieval is quick<br />
and easy. A range of intelligent querying and charting<br />
options transforms data from a collection of individual<br />
results into a store of valuable knowledge that aids faster<br />
decision-making.<br />
The Communiqué TM reporting environment provides<br />
customized report templates, including company logos,<br />
results, sample descriptions and spectra, using a simple<br />
drag and drop editor. GLP information, including method<br />
revision, analyst’s name and time and date of the analysis<br />
is automatically included, and reports can even be<br />
automatically e-mailed at the end of an analysis.<br />
The ES (Enhanced Security) version of UV WinLab v5<br />
software integrates technical compliance with the FDA<br />
regulation 21 CFR Part 11, within the workflow user<br />
interface. Unlike other packages with “bolt-on” compliance<br />
modules, UV WinLab ES eliminates compliance loopholes,<br />
without compromising productivity. E-signatures can be<br />
placed where you need them in the workflow.<br />
UV WinLab v5 Upgrade can be used to upgrade the<br />
LAMBDA 20, 25, 35, 40, 45, 6XX, 8XX, and 9XX. Earlier<br />
instruments are not supported. UV WinLab v5 does NOT<br />
support the following accessories:<br />
Research Peltiers (PTP-1 and PTP-6)<br />
Vacuum Pinch Sipper<br />
Vacuum Solenoid Sipper<br />
Gel-Scanner Linear Transport for Gels and Glasses<br />
The Research Peltiers can be used with UV WinLab ES v5<br />
but any setting of the temperature of ramping must be<br />
performed via the local interface on the accessory.<br />
Upgrade Information Part No. Each (€)<br />
From UV WinLab v3 or Lower to UV WinLab v5 L6100095 1564<br />
From UV WinLab v3 or Lower to UV WinLab ES v5 L6100096 3753<br />
From UV WinLab v4 to UV WinLab v5 L6100097 375<br />
From UV WinLab v4 to UV WinLab ES v5 L6100099 1251<br />
From UV WinLab v4 ES to UV WinLab ES v5 L6100098 375<br />
UV WinLab v5 Multi-User License<br />
Description Part No. Each (€)<br />
UV WinLab v5 5-User License L6100102 5600<br />
UV WinLab ES v5 5-User License L6100103 9000<br />
UV WinLab v5 10-User License L6100104 9700<br />
UV WinLab ES v5 10-User License L6100105 15500<br />
UV WinLab 2.8 Upgrade for<br />
LAMBDA 1X/2X/3X/4X/Bio<br />
Part No.<br />
Each (€)<br />
L6100013 1327<br />
398
Polarimetry Supplies<br />
Polarimetry Consumables<br />
Polarimetry Cells<br />
Our polarimetry cells are exclusively manufactured for<br />
PerkinElmer. Use them to maintain the high level of accuracy<br />
and precision of your PerkinElmer Polarimeter. They are<br />
manufactured by a special process in which the windows<br />
are fused to the cell bodies to ensure that they are free<br />
of tension. Because the windows are not mechanically<br />
inserted, birefringence effects, which could affect the<br />
accuracy of your reading, are eliminated.<br />
Each of our polarimetry cells is individually tested with<br />
respect to its pathlength. The actual pathlength of each cell<br />
is engraved on the cell to the nearest 0.001 cm (i.e. to the<br />
nearest 0.01 mm), together with the serial number of the cell.<br />
All cells are jacketed for thermostatting with constant<br />
temperature water, except for one flowcell. Their residual<br />
cell rotation is almost zero and may be neglected in<br />
most measurements.<br />
Cells are designed for easy filling and emptying, with no<br />
loss of sample. The filling ports are arranged so that liquid<br />
flows over the inner window surfaces. A wide variety of<br />
cells made of fused silica are available. These cells are used<br />
for measurements of optical rotation in the ultraviolet range<br />
or at elevated temperatures.<br />
PerkinElmer offers a wide range of polarimetry sample<br />
cells for virtually all applications, including micro cells,<br />
short path cells, flow cells, and fused silica (quartz) cells.<br />
Use quartz cells for all wavelengths and for elevated<br />
temperatures (200 °C, maximum). Use glass cells only<br />
for visible wavelengths, above 400 nm.<br />
Standard Cells for Polarimetry<br />
Material Lightpath Cell Vol. Part No. Each (€)<br />
Quartz, Fused Silica 100 mm 6.2 mL B0041696 1006<br />
Quartz, Fused Silica* 100 mm 3.0 mL B0507403 1297<br />
Optical Glass 100 mm 6.2 mL B0041693 677<br />
Optical Glass* 100 mm 3.0 mL B0507447 643<br />
* Reduced volume<br />
Short Path Cells for Polarimetry<br />
Material Lightpath Cell Vol. Part No. Each (€)<br />
Quartz, Fused Silica 20 mm 1.3 mL B0022087 1836<br />
Quartz, Fused Silica 10 mm 0.6 mL B0022088 1440<br />
Optical Glass 10 mm 0.5 mL B0017052 896<br />
Optical Glass 1 mm 0.25 mL B0017057 896<br />
Micro Cells for Polarimetry<br />
Material Lightpath Cell Vol. Part No. Each (€)<br />
Quartz, Fused Silica 100 mm 1.0 mL B0023365 1396<br />
Quartz, Fused Silica* 100 mm 0.35 mL B0131186 1781<br />
Optical Glass 100 mm 1.0 mL B0017047 690<br />
* With reduced inner diameter<br />
Beaker Cells for Polarimetry<br />
Beaker cells are not thermostattable.<br />
Material Lightpath Cell Vol. Part No. Each (€)<br />
Quartz, Fused Silica 100 mm 50 mL B0023363 1396<br />
Optical Glass 100 mm 50 mL B0017041 451<br />
Flow Cells for Polarimetry<br />
Material Lightpath Cell Vol. Part No. Each (€)<br />
Quartz, Fused Silica* 100 mm 6.2 mL B0507451 1539<br />
Optical Glass 100 mm 5.0 mL B0017054 951<br />
* With two PTFE tubing (4 mm i.d.)<br />
LC Cells for Polarimetry<br />
LC cells have PTFE connecting capillaries, and<br />
are not thermostattable.<br />
Material Lightpath Cell Vol. Part No. Each (€)<br />
Quartz, Fused Silica 100 mm 80 μL B0107592 2028<br />
Quartz, Fused Silica 100 mm 40 μL B0107593 2265<br />
LC Alignment Cell<br />
For aligning the special LC cell holder.<br />
Part No.<br />
Each(€)<br />
B0017072 753<br />
Polarimetry Supplies UV Visible<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
399
Polarimetry Supplies<br />
Polarimetry Consumables and Software<br />
UV Visible Polarimetry Supplies<br />
Interference Filters, Replacement<br />
Parts and Source Lamps<br />
Optional Interference Filter<br />
For Model 341 Polarimeters.<br />
Service installation recommended.<br />
Wavelength Part No. Each (€)<br />
302 nm B0094404 706<br />
325 nm B2100154 933<br />
405 nm B0062666 649<br />
Pluggable Coupling<br />
For cell thermostatting.<br />
Connection Part No. Each (€)<br />
Female B0023491 54<br />
Male B0023492 43<br />
PTFE Stopper<br />
10 mm long.<br />
Cell Compatibility Diameter Part No. Each (€)<br />
017 047/017 057/022 086 - 3 mm B0017059 4<br />
022 091/023 365/037 634/<br />
037 635/022 085/037 357<br />
041 693/041 696 6 mm B0041695 4<br />
Polyethylene Protective End Caps<br />
For polarimetry cells and quartz<br />
control plates. (pkg. 20)<br />
Source Lamps<br />
Part No.<br />
Each (€)<br />
B0076786 21<br />
High-quality source lamps, specifically selected to optimize<br />
the performance of all PerkinElmer Polarimeters, offer high<br />
radiant energy and a long operating lifetime. As a result,<br />
precise measurements of optical rotation can be made,<br />
even when the sample absorbs strongly.<br />
Description Polarimeter Model Part No. Each (€)<br />
Sodium, 20 W 341/343/343plus/341LC/ B0008754 345<br />
241/241MC/243/243B<br />
Mercury Vapor (St46) 341/343S/343plus/341LC B0510581 585<br />
Polarimetry Software<br />
Pol WinLab Software CD Upgrade Kit<br />
A software upgrade for PerkinElmer polarimeters. Pol<br />
WinLab software allows complete instrument control with<br />
data acquisition and storage. Both Wavelength Program and<br />
Time drive methods are equipped with a report generator<br />
and result calculator. The software package also includes<br />
instrument validation and pre-programmed methods for<br />
most common applications.<br />
Does not support 14X and 24X Series polarimeters.<br />
Requires, but does not include, PC<br />
and RS-232C Cable (B0180242).<br />
Part No.<br />
Pol WinLab ES Software CD Kit<br />
An optional 21 CFR Part II compliant software package for<br />
PerkinElmer polarimeters. Pol WinLab ES software allows<br />
complete instrument control with data acquisition and<br />
storage. Both Wavelength Program and Time drive methods<br />
are equipped with a report generator and result calculator.<br />
The software package also includes instrument validation<br />
and pre-programmed methods for most common<br />
applications. The Software package offers full security<br />
features including electronic signature, password protected<br />
login, user rights, and audit trail.<br />
Does not support 14X and 24X Series polarimeters.<br />
Requires, but does not include, PC<br />
and RS-232C Cable (B0180242).<br />
Part No.<br />
Secondary Standards<br />
Secondary quartz standards are available for instrument<br />
validation. Quartz control plates can be calibrated for<br />
wavelengths in the visible spectral range only.<br />
Quartz Control Plate +1° at 589 nm<br />
With thermostattable housing,<br />
nominal rotation +1° at 589 nm<br />
(NaD). Secondary standard.<br />
Quartz Control Plate -1° at 589 nm<br />
With thermostattable housing,<br />
nominal rotation -1° at 589 nm<br />
(NaD). Secondary standard.<br />
Each (€)<br />
L6100081 1611<br />
Each (€)<br />
L6100082 4510<br />
Part No.<br />
Each (€)<br />
B0098800 3014<br />
Part No.<br />
Each (€)<br />
B0098799 3014<br />
400
Robust and comprehensive, efficient and uncomplicated<br />
ADVANCED Guide to Online Ordering<br />
www.perkinelmer.com/<strong>supplies</strong><br />
The PerkinElmer online ordering process is designed to help you find exactly what you need quickly and easily, and then<br />
receive it in a timely manner. Whether you choose QUICK Registration for streamlined service, or FULL Registration to gain<br />
all the advantages of the PerkinElmer ordering system, your shopping experience will be efficient and convenient.<br />
FULL Registration...<br />
Using FULL Registration increases<br />
the benefits of ordering online from<br />
PerkinElmer. You can:<br />
Enjoy a convenient process.<br />
Simply enter your account number,<br />
then confirm and select a billing address<br />
on the next page. If you don't have<br />
your account number available when<br />
ordering, submit your ship-to and/or<br />
bill-to addresses. After placing your<br />
order, you should receive an email<br />
notifying you that the order has been<br />
linked to your account.<br />
Receive special offers.<br />
You’ll have the opportunity to sign up<br />
for optional newsletters and periodic<br />
promotions so you can learn about and<br />
save on products you use every day.<br />
ADVANCED Guide to Online Ordering<br />
... vs. QUICK Registration<br />
If you want to place an order but<br />
don’t wish to receive the benefits<br />
of FULL Registration right now,<br />
then QUICK Registration is for you.<br />
With QUICK Registration, you can:<br />
Order with minimal information<br />
Shop by product number<br />
Get price and availability in the<br />
Shopping Cart<br />
PerkinElmer Consumables and Accessories<br />
For a complete listing of all local offices and mailing addresses go to pages 2-4 or visit<br />
www.perkinelmer.com/lasoffices or e-mail us: las.<strong>supplies</strong>@perkinelmer.com<br />
401
ADVANCED Guide to Online Ordering<br />
ADVANCED Guide to Online Ordering<br />
www.perkinelmer.com/<strong>supplies</strong><br />
Now that you’ve registered and are ready to order online, you’ll find many valuable tools that can simplify your experience.<br />
For example, you can recreate past orders to easily reorder what worked best for you, or even create a “Favorites” list to<br />
keep those product numbers handy. These features and others, described in detail below, can maximize your time online<br />
and help ensure your laboratory is fully stocked and running smoothly.<br />
When ordering from www.perkinelmer.com/<strong>supplies</strong> you can:<br />
Shop by product number • Quickly reorder from a favorites list or past order • Schedule recurring orders<br />
Estimate delivery time • Check order status • Track shipping<br />
Shop by<br />
Product Number<br />
Simply enter the desired product<br />
number found on our website,<br />
or the part number in this<br />
catalog. For your convenience,<br />
you can add up to 20 products<br />
to your Shopping Cart at one time.<br />
PerkinElmer Consumables and Accessories<br />
Create a Favorites List<br />
Another way to expedite orders is to create a “Favorites” list. Simply add<br />
products from any product page, past order or your Shopping Cart… 20 products<br />
can be stored at one time. Then, to order one or more of these items, simply click<br />
on “Favorites” from the Home Page or the My Account page to make your selection.<br />
402<br />
www.perkinelmer.com/<strong>supplies</strong>
ADVANCED Guide to Online Ordering<br />
www.perkinelmer.com/<strong>supplies</strong><br />
Recreate Past<br />
Orders Quickly<br />
This is a great time-saving feature if<br />
you typically order the same things<br />
frequently and have multiple line<br />
items per order. You can look up any<br />
past order – whether it was placed<br />
by phone, fax or online. From the<br />
Order Details page, you can choose<br />
some or all of the line items to add<br />
to a new Shopping Cart.<br />
ADVANCED Guide to Online Ordering<br />
Schedule Recurring Orders<br />
Do you have certain <strong>supplies</strong>, like<br />
Graphite Furnace Tubes, that constantly<br />
need replenishing? A Recurring Order<br />
ensures you’ll never run out by having<br />
a specified quantity automatically shipped<br />
on a regular basis. Save the time of<br />
re-ordering – you’ll get added savings, too.<br />
This valuable option allows you to<br />
schedule orders up to two years in advance,<br />
as if you were scheduling a recurring<br />
meeting on your calendar. You choose the<br />
order frequency: weekly, once every two<br />
weeks, monthly or once every two months.<br />
You can easily edit that schedule on the<br />
shipping confirmation page.<br />
For short-duration orders, you can design<br />
a customized shipping schedule for each<br />
line item, specifying exactly when you<br />
want the shipment to leave PerkinElmer –<br />
on the day it is available or a specific date<br />
in the future.<br />
PerkinElmer Consumables and Accessories<br />
For a complete listing of all local offices and mailing addresses go to pages 2-4 or visit<br />
www.perkinelmer.com/lasoffices or e-mail us: las.<strong>supplies</strong>@perkinelmer.com<br />
403
ADVANCED Guide to Online Ordering<br />
PerkinElmer Consumables and Accessories ADVANCED Guide to Online Ordering<br />
www.perkinelmer.com/<strong>supplies</strong><br />
Check Product Availability<br />
Your Shopping Cart contains important information, including<br />
a “Delivery Time Estimation” for each product you order. The<br />
“Date Available” shows when the product will be available for<br />
shipping and, for your convenience, exceptions to<br />
the normal shipping time will be indicated. On<br />
this page you also have the ability to select future<br />
shipment dates that better fit your needs.<br />
Here, you can also determine the status of<br />
your order and view its progress using our<br />
tracking capabilities – whether that order<br />
was placed by phone, fax or online.<br />
Customize your<br />
Shipping Information<br />
To ensure your materials reach their destination<br />
safely, you can customize your shipping information<br />
in several ways –<br />
“Attention/Recipient” is the name that will appear on<br />
the shipping label and packing list to correctly route the<br />
shipment when it arrives at your company.<br />
“Special Shipping Instructions” enable you to designate<br />
a shipping carrier and account number, or request special<br />
packaging for hazardous materials. These will be reviewed by<br />
PerkinElmer Customer Care and appear on the packing list.<br />
“Internal Delivery Instructions” are more specific<br />
directions you can include. They will appear on the<br />
packing list to help your receiving department. They<br />
could include information such as building and lab number,<br />
receiving hours or special handling instructions.<br />
“Customer Specific Instructions” allow you to take even<br />
greater control of your account by establishing permanent<br />
messages that will pop up each time an order is entered.<br />
You can identify details such as valid internal Purchase<br />
Order formats and authorized purchasers.<br />
404 www.perkinelmer.com/<strong>supplies</strong>
ADVANCED Guide to Online Ordering<br />
www.perkinelmer.com/<strong>supplies</strong><br />
ADVANCED Guide to Online Ordering<br />
Online Help (and how to get it)<br />
Our goal is to streamline your shopping experience. We are available to assist in many ways:<br />
“Ask Customer Care” link: Located on each page of registration and checkout, the symbol will lead you<br />
to page-specific help as well as the contact information for Customer Care.<br />
Help windows: If you see a term or phrase with a dashed underline, simply click on it for clarification.<br />
“How to Order Online” link: Look for this window in the “My Account” section found at www.perkinelmer.com/las.<br />
You’ll get a comprehensive overview to ordering online with PerkinElmer.<br />
Questions? Our knowledgeable Customer<br />
Care Representatives are ready to help.<br />
Simply contact your local PerkinElmer office<br />
(see pages 2-4 for local office listings).<br />
PerkinElmer Consumables and Accessories<br />
For a complete listing of all local offices and mailing addresses go to pages 2-4 or visit<br />
www.perkinelmer.com/lasoffices or e-mail us: las.<strong>supplies</strong>@perkinelmer.com<br />
405
Indexes<br />
Indexes
00071006 – 03190035 Part Number Index<br />
Index<br />
Part Number<br />
407<br />
00071006 . . . . . . . . . . . . . . . . . . . . . . . . . . . 56<br />
00080100 . . . . . . 131-132, 135, 139, 141, 153<br />
00090652 . . . . . . . . . . . . . . . . . . . . . . . . . . 159<br />
00090699 . . . . . . . . . . . . . . . . . . . . . . . 90, 272<br />
00090709 . . . . . . . . . . . . . . . . . . . . . . . . . . . 80<br />
00091279 . . . . . . . . . . . . . . . . . . . . . . . . . . 134<br />
00091357 . . . . . . . . . . . . . . . . . . . . . . . . . . 159<br />
00091667 . . . . . . . . . . . . . . . . . . . . . . . . . . 131<br />
00230090 . . . . . . . . . . . . . . . . . . . . . . 165, 318<br />
00230091 . . . . . . . . . . . . . . . . . . . . . . . . . . 165<br />
00230111 . . . . . . . . . . . . . . . . . . . . . . . . . . 162<br />
00230113 . . . . . . . . . . . . . . . . . . . . . . . . . . 161<br />
00230177 . . . . . . . . . . . . . . . . . . . . . . . . . . 162<br />
00230178 . . . . . . . . . . . . . . . . . . . . . . . . . . 162<br />
00230253 . . . . . . . . . . . . . . . . . . . . . . . . . . 165<br />
00230522 . . . . . . . . . . . . . . . . . . . . . . . . . . 167<br />
00230523 . . . . . . . . . . . . . . . . . . . . . . . . . . 161<br />
00400266 . . . . . . . . . . . . . . . . . . . . . . . . . . . 14<br />
00400275 . . . . . . . . . . . . . . . . . . . . . . . . . . . 14<br />
00400276 . . . . . . . . . . . . . . . . . . . . . . . . . . . 14<br />
00400277 . . . . . . . . . . . . . . . . . . . . . . . . . . . 14<br />
00400289 . . . . . . . . . . . . . . . . . . . . . . . . . . . 14<br />
00402237 . . . . . . . . . . . . . . . . . . . . . . 291-292<br />
00402239 . . . . . . . . . . . . . . . . . . . . . . . . . . 291<br />
00402240 . . . . . . . . . . . . . . . . . . . . . . . . . . 291<br />
00402241 . . . . . . . . . . . . . . . . . . . . . . . . . . 291<br />
00402243 . . . . . . . . . . . . . . . . . . . . . . . . . . 291<br />
00403058 . . . . . . . . . . . . . . . . . . . . . . . . . . 291<br />
00470258 . . . . . . . . . . . . . . . . . . . . . . . . . . . 37<br />
00470391 . . . . . . . . . . . . . . . . . . . . . . . . . . . 14<br />
00470551 . . . . . . . . . . . . . . . . . . . . . . . . . . 218<br />
00470608 . . . . . . . . . . . . . . . . . . . . . . . . . . 218<br />
00470652 . . . . . . . . . . . . . . . . . . . . . . . 36, 216<br />
00470988 . . . . . . . . . . . . . . . . . . . . . . . . 13-14<br />
00471420 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9<br />
00471422 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9<br />
00471440 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8<br />
00471441 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8<br />
00472014 . . . . . . . . . . . . . . . . . . . . . . . . 13-14<br />
00472020 . . . . . . . . . . . . . . . . . . . . . . . . . . 221<br />
00472022 . . . . . . . . . . . . . . . . . . . . . . . . . . 221<br />
00473194 . . . . . . . . . . . . . . . . . . 197, 229-230<br />
00473292 . . . . . . . . . . . . . . . . . . . . . . 195, 220<br />
00473449 . . . . . . . . . . . . . . . . . . . . . . . . . . 218<br />
00473539 . . . . . . . . . . . . . . . . . . . . . . 198, 223<br />
00473543 . . . . . . . . . . . . . . . . . . . . . . 198, 223<br />
00473550 . . . . . . . . . . . . . . . . . . . . . . 199, 224<br />
00473552 . . . . . . . . . . . . . . . . . . . . . . 199, 224<br />
00473578 . . . . . . . . . . . . . . . . . . . . . . . . . . 223<br />
00570194 . . . . . . . . . . . . . . . . . . . . . . . . . . . 45<br />
00570559 . . . . . . . . . . . . . . . . . . . . . . . . . . . 37<br />
00570567 . . . . . . . . . . . . . . . . . . . . . . . . . . . 37<br />
00570948 . . . . . . . . . . . . . . . . . . . . . . . . 13-14<br />
00570957 . . . . . . . . . . . . . . . . . . . . . . . . . . . 17<br />
00570984 . . . . . . . . . . . . . . . . . . . . . . . . 13-14<br />
00572561 . . . . . . . . . . . . . . . . . . . . . . . . 13-15<br />
00572615 . . . . . . . . . . . . . . . . . . . . . . . . 13-14<br />
00572616 . . . . . . . . . . . . . . . . . . . . . . . . . . . 14<br />
00572624 . . . . . . . . . . . . . . . . . . . . . . . . 13-14<br />
00572695 . . . . . . . . . . . . . . . . . . . . . . . . 13-14<br />
00572737 . . . . . . . . . . . . . . . . . . . . . . . . . . . 14<br />
00873032 . . . . . . . . . . . . . . . . . . . . . . . . . . 323<br />
00873035 . . . . . . . . . . . . . . . . . . . . . . . . . . 327<br />
00873036 . . . . . . . . . . . . . . . . . . . . . . . . . . 327<br />
00890873 . . . . . . . . . . . . . . . . . . . . . . . . . . 323<br />
00890893 . . . . . . . . . . . . . . . . . . . . . . . . . . 292<br />
00890945 . . . . . . . . . . . . . . . . . . . . . . . . . . 323<br />
00891480 . . . . . . . . . . . . . . . . . . . . . . . . . . 327<br />
00891542 . . . . . . . . . . . . . . . . . . . . . . . . . . 292<br />
00891543 . . . . . . . . . . . . . . . . . . . . . . . . . . 292<br />
00891544 . . . . . . . . . . . . . . . . . . . . . . . . . . 292<br />
01541498 . . . . . . . . . . . . . . . . . . . . . . 354-355<br />
01860436 . . . . . . . . . . . . . . . . . . . . . . . . . . 259<br />
01860449 . . . . . . . . . . . . . . . . . . . . . . . . . . 260<br />
01860470 . . . . . . . . . . . . . . . . . . . . . . . . . . 260<br />
018i60794. . . . . . . . . . . . . . . . . . . . . . . . . . 252<br />
01861854 . . . . . . . . . . . . . . . . . . . . . . . . . . 256<br />
01861861 . . . . . . . . . . . . . . . . . . . . . . . . . . 256<br />
01861862 . . . . . . . . . . . . . . . . . . . . . . . . . . 256<br />
01862289 . . . . . . . . . . . . . . . . . . . . . . . . . . 259<br />
01862292 . . . . . . . . . . . . . . . . . . . . . . . . . . 259<br />
01862295 . . . . . . . . . . . . . . . . . . . . . . . . . . 259<br />
01862301 . . . . . . . . . . . . . . . . . . . . . . . . . . 257<br />
01862812 . . . . . . . . . . . . . . . . . . . . . . . . . . 252<br />
02190041 . . . . . . . . . . . . . . . . . . . . . . . . . . 342<br />
02190042 . . . . . . . . . . . . . . . . . . . . . . . . . . 342<br />
02190045 . . . . . . . . . . . . . . . . . . . . . . . . . . 350<br />
02190048 . . . . . . . . . . . . . . . . . . . . . . . . . . 344<br />
02190061 . . . . . . . . . . . . . . . . . . . . . . . . . . . 80<br />
02190062 . . . . . . . . . . . . . . . . . . . . . . . . . . 339<br />
02190071 . . . . . . . . . . . . . . . . . . . . . . . . . . 368<br />
02190080 . . . . . . . . . . . . . . . . . . . . . . 339, 372<br />
02190136 . . . . . . . . . . . . . . . . . . . . . . . . . . 350<br />
02191269 . . . . . . . . . . . . . . . . . . . . . . . . . . 366<br />
02191858 . . . . . . . . . . . . . . . . . . . . . . . . . . 366<br />
02200550 . . . . . . . . . . . . . . . . . . . . . . . . . . 249<br />
02400011 . . . . . . . . . . . . . . . . . . . . . . . . . . 355<br />
02400084 . . . . . . . . . . . . . . . . . . . . . . . 77, 354<br />
02400085 . . . . . . . . . . . . . . . . . . . . . . . . . . 355<br />
02400115 . . . . . . . . . . . . . . . . . . . . . . . . 76, 78<br />
02400117 . . . . . . . . . . . . . . . . . . . . . . . . . . . 78<br />
02400119 . . . . . . . . . . . . . . . . . . . . . . . . 76, 78<br />
02400137 . . . . . . . . . . . . . . . . . . . . . . . . 81-82<br />
02400642 . . . . . . . . . . . . . . . . . . . . . . . . . . . 80<br />
02400815 . . . . . . . . . . . . . . . . . . . . . . . . . . . 78<br />
02401028 . . . . . . . . . . . . . . . . . . . . . . . . 81-82<br />
02401042 . . . . . . . . . . . . . . . . . . . . . . . . 81-82<br />
02401092 . . . . . . . . . . . . . . . . . . . . . . . . . . . 78<br />
02401117 . . . . . . . . . . . . . . . . . . . . . . . . . . . 78<br />
02401118 . . . . . . . . . . . . . . . . . . . . . . . . . . . 78<br />
02401119 . . . . . . . . . . . . . . . . . . . . . . . . 76, 78<br />
02401120 . . . . . . . . . . . . . . . . . . . . . . . . 76, 80<br />
02401121 . . . . . . . . . . . . . . . . . . . . . . . . 76, 80<br />
02401286 . . . . . . . . . . . . . . . . . . . . . . . . . . . 80<br />
02401291 . . . . . . . . . . . . . . . . . . . . . . . . . . . 83<br />
02401293 . . . . . . . . . . . . . . . . . . . . . . . . . . . 83<br />
02401294 . . . . . . . . . . . . . . . . . . . . . . . . . . . 82<br />
02401296 . . . . . . . . . . . . . . . . . . . . . . . . . . . 80<br />
02401344 . . . . . . . . . . . . . . . . . . . . . . . . . . . 78<br />
02401347 . . . . . . . . . . . . . . . . . . . . . . . . . . . 80<br />
02401362 . . . . . . . . . . . . . . . . . . . . . . . . 76, 78<br />
02401583 . . . . . . . . . . . . . . . . . . . . . . . . 81-82<br />
02402087 . . . . . . . . . . . . . . . . . . . . . . . . . . . 83<br />
02402089 . . . . . . . . . . . . . . . . . . . . . . . . . . . 83<br />
02450972 . . . . . . . . . . . . . . . . . . . . . . . . . . . 94<br />
02506483 . . . . . . . . . . . . . . . . . . 167, 223, 318<br />
02506495 . . . . . . . . . . . . . . . . . . . . . . . . . . 273<br />
02506516 . . . . . . . . . . . . . . . . . . 221, 229-230<br />
02506517 . . . . . . . . . . . . . . . . . . 221, 229-230<br />
02506518 . . . . . . . . . . . . . . . . . . . . . . . . . . 167<br />
02506519 . . . . . . . . . . . . . . . . . . . . . . . . . . 218<br />
02506532 . . . . . . . . . . . . . . . . . . . . . . 218, 226<br />
02507907 . . . . . . . . . . 357-358, 360, 363, 366<br />
02507987 . . . . . . . . . . . . . . . . . . . . . . . . . . . 13<br />
02507999 . . . . . . . . . . . . . . . . . . . . . . . . . . 243<br />
02508059 . . . . . . . . . . . . . . . . . . . . . . . . . . 226<br />
02508063 . . . . . . . . . . . . . . . . . . . . . . 243-244<br />
02508065 . . . . . . . . . . . . . . . . . . . . . . . . . . 243<br />
02508080 . . . . . . . . . . . . . . . . . . . . . . . . . . 199<br />
02509115 . . . . . . . . . . . . . . . . . . . . . . . . . . 216<br />
02540142 . . . . . . . . . . . . . . . . . . . . . . . . . . 324<br />
02540177 . . . . . . . . . . . . . . . . . . . . . . 319-320<br />
02540197 . . . . . . . . . . . . . . . . . . . . . . 319-320<br />
02540272 . . . . . . . . . . . . . . . . . . . . . . . . . . 321<br />
02540273 . . . . . . . . . . . . . . . . . . . . . . . . . . 323<br />
02540274 . . . . . . . . . . . . . . . . . . . . . . . . . . 323<br />
02540311 . . . . . . . . . . . . . . . . . . . . . . . . . . 322<br />
02540582 . . . . . . . . . . . . . . . . . . . . . . . . . . 273<br />
02540838 . . . . . . . . . . . . . . . . . . . . . . . . . . 327<br />
02540871 . . . . . . . . . . . . . . . . . . . . . . . . . . 321<br />
02541946 . . . . . . . . . . . . . . . . . . . . . . . . . . 325<br />
02542076 . . . . . . . . . . . . . . . . . . . . . . 319-320<br />
02542313 . . . . . . . . . . . . . . . . . . . . . . 319-320<br />
02542782 . . . . . . . . . . . . . . . . . . . . . . . . . . 327<br />
02542783 . . . . . . . . . . . . . . . . . . . . . . . . . . 327<br />
02580164 . . . . . . . . . . . . . . . . . . . . . . . . . . 289<br />
02580166 . . . . . . . . . . . . . . . . . . . . . . . . . . 289<br />
02580167 . . . . . . . . . . . . . . . . . . . . . . . . . . 289<br />
02580168 . . . . . . . . . . . . . . . . . . . . . . . . . . 289<br />
02580169 . . . . . . . . . . . . . . . . . . . . . . . . . . 289<br />
02580191 . . . . . . . . . . . . . . . . . . . . . . . . . . 289<br />
02580192 . . . . . . . . . . . . . . . . . . . . . . . . . . 289<br />
02580194 . . . . . . . . . . . . . . . . . . . . . . . . . . 289<br />
02580195 . . . . . . . . . . . . . . . . . . . . . . . . . . 289<br />
02580202 . . . . . . . . . . . . . . . . . . . . . . . . . . 289<br />
02580203 . . . . . . . . . . . . . . . . . . . . . . . . . . 289<br />
02580213 . . . . . . . . . . . . . . . . . . . . . . . . . . 289<br />
02711441 . . . . . . . . . . . . . . . . . . . . . . . . . . 327<br />
02712273 . . . . . . . . . . . . . . . . . . . . . . . . . . 315<br />
02900540 . . . . . . . . . . . . . . . . . . . . . . . . . . . 67<br />
02901518 . . . . . . . . . . . . . . . . . . . . . . . . . . . 45<br />
02901624 . . . . . . . . . . . . . . . . . . . . . . . . . . 354<br />
03030106 . . . . . . . . . . . . . . . . . . . . . . . . . . . 38<br />
03030130 . . . . . . . . . . . . . . . . . . . . . . . . . . . 14<br />
03030135 . . . . . . . . . . . . . . . . . . . . . . . . . . . 18<br />
03030204 . . . . . . . . . . . . . . . . . . . . . . . . . . . 38<br />
03030264 . . . . . . . . . . . . . . . . . . . . . . . . . . . 38<br />
03030284 . . . . . . . . . . . . . . . . . . . . . . . . . . . 38<br />
03030299 . . . . . . . . . . . . . . . . . . . . . . . . . . . 17<br />
03030313 . . . . . . . . . . . . . . . . . . . . . . . . . . 216<br />
03030314 . . . . . . . . . . . . . . . . . . . . . . . . . . 216<br />
03030352 . . . . . . . . . . . . . . . . . . . . . . . . 17, 20<br />
03030353 . . . . . . . . . . . . . . . . . . . . . . . . . . . 20<br />
03030354 . . . . . . . . . . . . . . . . . . . . . . . . . . . 17<br />
03030402 . . . . . . . . . . . . . . . . . . . . . . . . . . . 17<br />
03030404 . . . . . . . . . . . . . . . . . . . . . . . . . . . 17<br />
03030405 . . . . . . . . . . . . . . . . . . . . . . . . . . . 18<br />
03030406 . . . . . . . . . . . . . . . . . . . . . . . 38, 217<br />
03030433 . . . . . . . . . . . . . . . . . . . . . . . . . . . 17<br />
03030791 . . . . . . . . . . . . . . . . . . . . . . . . . . . 48<br />
03030793 . . . . . . . . . . . . . . . . . . . . . . . . . . . 48<br />
03030952 . . . . . . . . . . . . . . . . . . . . . . . . . . . 48<br />
03030972 . . . . . . . . . . . . . . . . . . . . . . . . . . . 48<br />
03030997 . . . . . . . . . . . . . . . . . . . . . . . . . . . 48<br />
03030998 . . . . . . . . . . . . . . . . . . . . . . . . . . . 48<br />
03031456 . . . . . . . . . . . . . . . . . . . . . . . . . . . 20<br />
03031460 . . . . . . . . . . . . . . . . . . . . . . . . . . . 20<br />
03031573 . . . . . . . . . . . . . . . . . . . . . . . . 13-15<br />
03031802 . . . . . . . . . . . . . . . . . . . . . . . . . . . 20<br />
03031806 . . . . . . . . . . . . . . . . . . . . . . . . . . . 20<br />
03031808 . . . . . . . . . . . . . . . . . . . . . . . . . . . 20<br />
03031810 . . . . . . . . . . . . . . . . . . . . . . . . . . . 17<br />
03031812 . . . . . . . . . . . . . . . . . . . . . . . . . . . 20<br />
03031910 . . . . . . . . . . . . . . . . . . . . . . . 38, 217<br />
03031920 . . . . . . . . . . . . . . . . . . . . . . . . . . . 17<br />
03033124 . . . . . . . . . . . . . . . . . . . . . . . . . . . 17<br />
03190021 . . . . . . . . . . . . . . . . . . . . . . . . . . 341<br />
03190024 . . . . . . . . . . . . . . . . . . . . . . . . . . 343<br />
03190025 . . . . . . . . . . . . . . . . . . . . . . . . . . 343<br />
03190026 . . . . . . . . . . . . . . . . . . . . . . . . . . 342<br />
03190029 . . . . . . . . . . . . . . . . . . . . . . 340-341<br />
03190030 . . . . . . . . . . . . . . . . . . . . . . . . . . 351<br />
03190031 . . . . . . . . . . . . . . . . . . . . . . . . . . 351<br />
03190033 . . . . . . . . . . . . . . . . . . 350, 366-367<br />
03190034 . . . . . . . . . . . . . . . . . . . . . . 350, 367<br />
03190035 . . . . . . . . . . . . . . . . . . . . . . 350, 367<br />
Part No. Page Part No. Page Part No. Page<br />
See page 4 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
See page 2 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong>
Index Part Number 03190036 – 09290148<br />
Index<br />
Part Number<br />
408<br />
03190036 . . . . . . . . . . . . . . . . . . 350, 366-367<br />
03190062 . . . . . . . . . . . . . . . . . . . . . . . . . . 350<br />
03190205 . . . . . . . . . . . . . . . . . . . . . . . . . . 347<br />
03190206 . . . . . . . . . . . . . . . . . . . . . . . . . . 347<br />
03190207 . . . . . . . . . . . . . . . . . . . . . . . . . . 347<br />
03190208 . . . . . . . . . . . . . . . . . . . . . . . . . . 347<br />
03190218 . . . . . . . . . . . . . . . . . . . . . . 340-341<br />
03190236 . . . . . . . . . . . . . . . . . . . . . . 341, 351<br />
03190247 . . . . . . . . . . . . . . . . . . . . . . . . . . 347<br />
03190253 . . . . . . . . . . . . . . . . . . . . . . . . . . 369<br />
03190264 . . . . . . . . . . . . . . . . . . . . . . . . . . 372<br />
03190265 . . . . . . . . . . . . . . . . . . . . . . . . . . 371<br />
03190461 . . . . . . . . . . . . . . . . . . . . . . . . . . 364<br />
03191024 . . . . . . . . . . . . . . . . . . . . . . . . . . 348<br />
03191047 . . . . . . . . . . . . . . . . . . . . . . . . . . 341<br />
03191527 . . . . . . . . . . . . . . . . . . . . . . . . . . 347<br />
03191628 . . . . . . . . . . . . . . . . . . . . . . . . . . 369<br />
03191705 . . . . . . . . . . . . . . . . . . . . . . . . . . 364<br />
03191719 . . . . . . . . . . . . . . . . . . . . . . . . . . 347<br />
03191720 . . . . . . . . . . . . . . . . . . . . . . . . . . 347<br />
03220067 . . . . . . . . . . . . . . . . . . . . . . . . . . 375<br />
03220068 . . . . . . . . . . . . . . . . . . . . . . . . . . 375<br />
03300806 . . . . . . . . . . . . . . . . . . . . . . . . . . 271<br />
03300865 . . . . . . . . . . . . . . . . . . . . . . . . . . 140<br />
03300866 . . . . . . . . . . . . . . . . . . . . . . . . . . 140<br />
03300904 . . . . . . . . . . . . . . . . . . . . . . . . . . 150<br />
03300905 . . . . . . . . . . . . . . . . . . . . . . . . . . 153<br />
03302775 . . . . . . . . . . . . . . . . . . . . . . . . . . 140<br />
03302777 . . . . . . . . . . . . . . . . . . . . . . . . . . 140<br />
03302778 . . . . . . . . . . . . . . . . . . . . . . . . . . 140<br />
03302973 . . . . . . . . . . . . . . . . . . . . . . . . . . 140<br />
03302976 . . . . . . . . . . . . . . . . . . . . . . . . . . 140<br />
03302979 . . . . . . . . . . . . . . . . . . . . . . . . . . 140<br />
03302989 . . . . . . . . . . . . . . . . . . . . . . . . . . 140<br />
03303598 . . . . . . . . . . . . . . . . . . . . . . . . . . 140<br />
03303599 . . . . . . . . . . . . . . . . . . . . . . . . . . 140<br />
03303773 . . . . . . . . . . . . . . . . . . . . . . . . . . 140<br />
04190117 . . . . . . . . . . . . . . . . . . . . . . . . . . 353<br />
04190119 . . . . . . . . . . . . . . . . . . . . . . . . . . 353<br />
04190163 . . . . . . . . . . . . . . . . . . . . . . . . . . 353<br />
04190165 . . . . . . . . . . . . . . . . . . . . . . . . . . 353<br />
04190166 . . . . . . . . . . . . . . . . . . . . . . . . . . 353<br />
04190197 . . . . . . . . . . . . . . . . . . . . . . 353, 364<br />
04190217 . . . . . . . . . . . . . . . . . . . . . . . . . . 353<br />
04190226 . . . . . . . . . . . . . . . . . . . . . . . . . . . 77<br />
04190299 . . . . . . . . . . . . . . . . . . . . . . . . . . 351<br />
04190367 . . . . . . . . . . . . . . . . . . . . . . . . . . 348<br />
04190387 . . . . . . . . . . . . . . . . . . . . . . . . . . 353<br />
04190388 . . . . . . . . . . . . . . . . . . . . . . . . . . 353<br />
04191228 . . . . . . . . . . . . . . . . . . . . . . . . . . 353<br />
04191290 . . . . . . . . . . . . . . . . . . . . . . . . . . 353<br />
04191291 . . . . . . . . . . . . . . . . . . . . . . . . . . 353<br />
04191577 . . . . . . . . . . . . . . . . . . . . . . . . . . 348<br />
04191838 . . . . . . . . . . . . . . . . . . . . . . . . . . 353<br />
04191839 . . . . . . . . . . . . . . . . . . . . . . . . . . 353<br />
04308523 . . . . . . . . . . . . . . . . . . . . . . . . . . 138<br />
04800514 . . . . . . . . . . . . . . . . . . . . . . . . . . 258<br />
04810949 . . . . . . . . . . . . . . . . . . . . . . . . . . 258<br />
04820519 . . . . . . . . . . . . . . . . . . . . . . . . . . 258<br />
04821008 . . . . . . . . . . . . . . . . . . . . . . 248, 251<br />
04821131 . . . . . . . . . . . . . . . . . . . . . . 248, 251<br />
04821132 . . . . . . . . . . . . . . . . . . . . . . 248, 251<br />
04960691 . . . . . . . . . . . . . . . . . . . . . . . . . . 257<br />
04967843 . . . . . . . . . . . . . . . . . . . . . . . . . . 257<br />
04967845 . . . . . . . . . . . . . . . . . . . . . . 250, 257<br />
04967854 . . . . . . . . . . . . . . . . . . . . . . . . . . 257<br />
04969486 . . . . . . . . . . . . . . . . . . . . . . . . . . 315<br />
04970343 . . . . . . . . . . . . . . . . . . . . . . 181, 183<br />
04970573 . . . . . . . . . . . . . . . . . . . . . . . . . . 242<br />
04970839 . . . . . . . . . . . . . . . . . . . . . . . . . . 242<br />
04972066 . . . . . . . . . . . . . . . . . . . . . . . . . . 183<br />
04972383 . . . . . . . . . . . . . . . . . . . . . . . . . . 181<br />
04972392 . . . . . . . . . . . . . . . . . . . . . . . . . . . 94<br />
04973727 . . . . . . . . . . . . . . . . . . . . . . . . . . 181<br />
04974018 . . . . . . . . . . . . . . . . . . . . . . . . . . 183<br />
04974414 . . . . . . . . . . . . . . . . . . . . . . . . . . 180<br />
04974438 . . . . . . . . . . . . . . . . . . . . . . . . . . 260<br />
04977032 . . . . . . . . . . . . . . . . . . . . . . . . . . 258<br />
04977042 . . . . . . . . . . . . . . . . . . . . . . . . . . 258<br />
04977043 . . . . . . . . . . . . . . . . . . . . . . . . . . 257<br />
04978443 . . . . . . . . . . . . . . . . . . . . . . . . . . 258<br />
04978444 . . . . . . . . . . . . . . . . . . . . . . . . . . 258<br />
04978581 . . . . . . . . . . . . . . . . . . . . . . . . . . 241<br />
04978582 . . . . . . . . . . . . . . . . . . . . . . . . . . 241<br />
04978590 . . . . . . . . . . . . . . . . . . . . . . . . . . 241<br />
04994506 . . . . . . . . . . . . . . . . . . . . . . . . . . 240<br />
04994507 . . . . . . . . . . . . . . . . . . . . . . . . . . 240<br />
07110001 . . . . . . . . . . . . . . . . . . . . . . . . . . 286<br />
07110002 . . . . . . . . . . . . . . . . . . . . . . . . . . 286<br />
07110003 . . . . . . . . . . . . . . . . . . . . . . . . . . 286<br />
07110004 . . . . . . . . . . . . . . . . . . . . . . . . . . 287<br />
07110005 . . . . . . . . . . . . . . . . . . . . . . . . . . 287<br />
07110006 . . . . . . . . . . . . . . . . . . . . . . . . . . 287<br />
07110013 . . . . . . . . . . . . . . . . . . . . . . . . . . 286<br />
07110014 . . . . . . . . . . . . . . . . . . . . . . . . . . 286<br />
07110015 . . . . . . . . . . . . . . . . . . . . . . . . . . 286<br />
07110016 . . . . . . . . . . . . . . . . . . . . . . . . . . 287<br />
07110017 . . . . . . . . . . . . . . . . . . . . . . . . . . 287<br />
07110018 . . . . . . . . . . . . . . . . . . . . . . . . . . 287<br />
07110019 . . . . . . . . . . . . . . . . . . . . . . . . . . 286<br />
07110020 . . . . . . . . . . . . . . . . . . . . . . . . . . 286<br />
07110021 . . . . . . . . . . . . . . . . . . . . . . . . . . 286<br />
07110022 . . . . . . . . . . . . . . . . . . . . . . . . . . 287<br />
07110023 . . . . . . . . . . . . . . . . . . . . . . . . . . 287<br />
07110024 . . . . . . . . . . . . . . . . . . . . . . . . . . 287<br />
07110025 . . . . . . . . . . . . . . . . . . . . . . . . . . 286<br />
07110027 . . . . . . . . . . . . . . . . . . . . . . . . . . 286<br />
07110029 . . . . . . . . . . . . . . . . . . . . . . . . . . 287<br />
07110031 . . . . . . . . . . . . . . . . . . . . . . . . . . 286<br />
07110032 . . . . . . . . . . . . . . . . . . . . . . . . . . 286<br />
07110033 . . . . . . . . . . . . . . . . . . . . . . . . . . 286<br />
07110035 . . . . . . . . . . . . . . . . . . . . . . . . . . 287<br />
07110037 . . . . . . . . . . . . . . . . . . . . . . . . . . 286<br />
07110039 . . . . . . . . . . . . . . . . . . . . . . . . . . 286<br />
07110041 . . . . . . . . . . . . . . . . . . . . . . . . . . 287<br />
07110043 . . . . . . . . . . . . . . . . . . . . . . . . . . 286<br />
07110045 . . . . . . . . . . . . . . . . . . . . . . . . . . 286<br />
07110047 . . . . . . . . . . . . . . . . . . . . . . . . . . 287<br />
07110055 . . . . . . . . . . . . . . . . . . . . . . . . . . 286<br />
07110056 . . . . . . . . . . . . . . . . . . . . . . . . . . 286<br />
07110057 . . . . . . . . . . . . . . . . . . . . . . . . . . 286<br />
07110058 . . . . . . . . . . . . . . . . . . . . . . . . . . 287<br />
07110059 . . . . . . . . . . . . . . . . . . . . . . . . . . 287<br />
07110060 . . . . . . . . . . . . . . . . . . . . . . . . . . 287<br />
07110061 . . . . . . . . . . . . . . . . . . . . . . . . . . 286<br />
07110062 . . . . . . . . . . . . . . . . . . . . . . . . . . 286<br />
07110064 . . . . . . . . . . . . . . . . . . . . . . . . . . 287<br />
07110073 . . . . . . . . . . . . . . . . . . . . . . . . . . 286<br />
07110074 . . . . . . . . . . . . . . . . . . . . . . . . . . 286<br />
07110075 . . . . . . . . . . . . . . . . . . . . . . . . . . 286<br />
07110077 . . . . . . . . . . . . . . . . . . . . . . . . . . 287<br />
07110085 . . . . . . . . . . . . . . . . . . . . . . . . . . 286<br />
07110086 . . . . . . . . . . . . . . . . . . . . . . . . . . 292<br />
07110087 . . . . . . . . . . . . . . . . . . . . . . . . . . 286<br />
07110088 . . . . . . . . . . . . . . . . . . . . . . . . . . 292<br />
07110089 . . . . . . . . . . . . . . . . . . . . . . . . . . 287<br />
07110090 . . . . . . . . . . . . . . . . . . . . . . . . . . 292<br />
07110091 . . . . . . . . . . . . . . . . . . . . . . . . . . 286<br />
07110092 . . . . . . . . . . . . . . . . . . . . . . . . . . 292<br />
07110093 . . . . . . . . . . . . . . . . . . . . . . . . . . 286<br />
07110095 . . . . . . . . . . . . . . . . . . . . . . . . . . 287<br />
07110096 . . . . . . . . . . . . . . . . . . . . . . . . . . 292<br />
07110098 . . . . . . . . . . . . . . . . . . . . . . . . . . 292<br />
07110100 . . . . . . . . . . . . . . . . . . . . . . . . . . 292<br />
07110102 . . . . . . . . . . . . . . . . . . . . . . . . . . 292<br />
07110105 . . . . . . . . . . . . . . . . . . . . . . . . . . 292<br />
07110106 . . . . . . . . . . . . . . . . . . . . . . . . . . 292<br />
07110114 . . . . . . . . . . . . . . . . . . . . . . . . . . 290<br />
07110115 . . . . . . . . . . . . . . . . . . . . . . . . . . 286<br />
07110117 . . . . . . . . . . . . . . . . . . . . . . . . . . 286<br />
07110119 . . . . . . . . . . . . . . . . . . . . . . . . . . 287<br />
07110121 . . . . . . . . . . . . . . . . . . . . . . . . . . 286<br />
07110123 . . . . . . . . . . . . . . . . . . . . . . . . . . 286<br />
07110145 . . . . . . . . . . . . . . . . . . . . . . . . . . 286<br />
07110163 . . . . . . . . . . . . . . . . . . . . . . . . . . 290<br />
07110165 . . . . . . . . . . . . . . . . . . . . . . . . . . 290<br />
07110166 . . . . . . . . . . . . . . . . . . . . . . . . . . 290<br />
07110189 . . . . . . . . . . . . . . . . . . . . . . . . . . 290<br />
07110190 . . . . . . . . . . . . . . . . . . . . . . . . . . 290<br />
07110191 . . . . . . . . . . . . . . . . . . . . . . . . . . 290<br />
07110192 . . . . . . . . . . . . . . . . . . . . . . . . . . 290<br />
07110231 . . . . . . . . . . . . . . . . . . . . . . . . . . 287<br />
07110232 . . . . . . . . . . . . . . . . . . . . . . . . . . 286<br />
07110233 . . . . . . . . . . . . . . . . . . . . . . . . . . 287<br />
07110234 . . . . . . . . . . . . . . . . . . . . . . . . . . 286<br />
07110235 . . . . . . . . . . . . . . . . . . . . . . . . . . 286<br />
07110236 . . . . . . . . . . . . . . . . . . . . . . . . . . 287<br />
07120001 . . . . . . . . . . . . . . . . . . . . . . . . . . 311<br />
07120005 . . . . . . . . . . . . . . . . . . . . . . . . . . 311<br />
07120012 . . . . . . . . . . . . . . . . . . . . . . . . . . 311<br />
07120016 . . . . . . . . . . . . . . . . . . . . . . . . . . 311<br />
07120019 . . . . . . . . . . . . . . . . . . . . . . . . . . 311<br />
07120023 . . . . . . . . . . . . . . . . . . . . . . . . . . 311<br />
07120033 . . . . . . . . . . . . . . . . . . . . . . . . . . 309<br />
07120040 . . . . . . . . . . . . . . . . . . . . . . . . . . 309<br />
07120073 . . . . . . . . . . . . . . . . . . . . . . . . . . 309<br />
07120096 . . . . . . . . . . . . . . . . . . . . . . . . . . 309<br />
07120097 . . . . . . . . . . . . . . . . . . . . . . . . . . 309<br />
07120099 . . . . . . . . . . . . . . . . . . . . . . . . . . 309<br />
07150001 . . . . . . . . . . . . . . . . . . . . . . . . . . 293<br />
07150002 . . . . . . . . . . . . . . . . . . . . . . . . . . 293<br />
07150005 . . . . . . . . . . . . . . . . . . . . . . . . . . 293<br />
07150006 . . . . . . . . . . . . . . . . . . . . . . . . . . 293<br />
07150012 . . . . . . . . . . . . . . . . . . . . . . . . . . 292<br />
07150013 . . . . . . . . . . . . . . . . . . . . . . 208, 293<br />
07150014 . . . . . . . . . . . . . . . . . . . . . . . . . . 293<br />
07150015 . . . . . . . . . . . . . . . . . . . . . . . . . . 293<br />
07150016 . . . . . . . . . . . . . . . . . . . . . . 291, 293<br />
07150017 . . . . . . . . . . . . . . . . . . . . . . . . . . 293<br />
07150018 . . . . . . . . . . . . . . . . . . . . . . 291, 293<br />
07150019 . . . . . . . . . . . . . . . . . . . . . . . . . . 293<br />
07150020 . . . . . . . . . . . . . . . . . . . . . . . . . . 293<br />
07150021 . . . . . . . . . . . . . . . . . . . . . . . . . . 293<br />
07150022 . . . . . . . . . . . . . . . . . . . . . . . . . . 293<br />
07150023 . . . . . . . . . . . . . . . . . . . . . . . . . . 292<br />
07150024 . . . . . . . . . . . . . . . . . . . . . . . . . . 292<br />
07150025 . . . . . . . . . . . . . . . . . . . . . . . . . . 293<br />
07150026 . . . . . . . . . . . . . . . . . . . . . . . . . . 292<br />
07150028 . . . . . . . . . . . . . . . . . . . . . . . . . . 293<br />
07150029 . . . . . . . . . . . . . . . . . . . . . . . . . . 293<br />
07150030 . . . . . . . . . . . . . . . . . . . . . . . . . . 293<br />
07150031 . . . . . . . . . . . . . . . . . . . . . . . . . . 293<br />
07150032 . . . . . . . . . . . . . . . . . . . . . . . . . . 293<br />
09200010 . . . . . . . . . . . . . . . . . . . . . . . . . . 245<br />
09200011 . . . . . . . . . . . . . . . . . . . . . . . . . . 245<br />
09200012 . . . . . . . . . . . . . . . . . . . . . . . . . . 245<br />
09200013 . . . . . . . . . . . . . . . . . . . . . . . . . . 245<br />
09200017 . . . . . . . . . . . . . . . . . . . . . . . . . . 245<br />
09200091 . . . . . . . . . . . . . . . . . . . . . . 144, 183<br />
09210011 . . . . . . . . . . 193, 195, 201-202, 205<br />
09210012 . . . . . . . . . . . . . . 193, 195, 201, 205<br />
09290144 . . . . . . . . . . . . . . . . . . . . . . 177, 331<br />
09290145 . . . . . . . . . . . . . . . . . . . . . . 177, 331<br />
09290146 . . . . . . . . . . . . . . . . . . . . . . . . . . 177<br />
09290147 . . . . . . . . . . . . . . . . . . . . . . . . . . 177<br />
09290148 . . . . . . . . . . . . . . . . . . . . . . . . . . 331<br />
Part No. Page Part No. Page Part No. Page
09290149 – 09985727 Part Number Index<br />
Index<br />
Part Number<br />
409<br />
09290149 . . . . . . . . . . . . . . . . . . . . . . . . . . 331<br />
09410015 . . . . . . . . . . . . . . . . . . . . . . . . . . 331<br />
09410020 . . . . . . . . . . . . . . . . . . . . . . . . . . 331<br />
09410036 . . . . . . . . . . . . . . . . . . . . . . 316, 331<br />
09410047 . . . . . . . . . . . . . . . . . . . . . . . . . . 206<br />
09410077 . . . . . . . . . . . . . . . . . . . . . . . . . . 175<br />
09421018 . . . . . . . . . . . . . . . . . . . . . . . . . . . 77<br />
09421019 . . . . . . . . . . . . . . . . . . . . . . . . . . . 77<br />
09421021 . . . . . . . . . . . . . . . . . . . . . . . . . . . 77<br />
09902005 . . . . . . . . . . . . . . . . . . . . . . . . . . . 20<br />
09902006 . . . . . . . . . . . . . . . . . . . . . . 228-229<br />
09902015. . . . . . . . . . . . . 17-19, 226, 228-229<br />
09902018 . . . . . . . . . . . . . . . . . . . . . . . . . . 320<br />
09902031 . . . . . . . . . . . . . . . . . . . . . . . . . . 369<br />
09902033 . . . . . . . . . . . . . . . . . . . . . . 198, 223<br />
09902035 . . . . . . . . . . . . . . . . . . . . . . . . . . . 81<br />
09902048 . . . . . . . . . . . . . . . . . . . . . . . . . . . 81<br />
09902102 . . . . . . . . . . . . . . . . . . . . . . . 20, 350<br />
09902123 . . . . . . . . . . . . . . . . . . . . . . . . . . . 81<br />
09902128 . . . . . . . . . . . . . . . . . . . . . . 319-320<br />
09902131 . . . . . . . . . . . . . . . . . . . . . . . . . . 369<br />
09902143 . . . . . . . . . . . . . . . . . . . . . . 132-133<br />
09902147 . . . . . . . . . . . . . . . . . . . . . . . . 13-14<br />
09902152 . . . . . . . . . . . . . . . . . . . . . . . . . . 228<br />
09902153 . . . . . . . . . . . . . . . . . . . . . . . . . . 197<br />
09902155 . . . . . . . . . . . . . . . . . . . . . . 228-230<br />
09902163 . . . . . . . . . . . . . . . . . . . . . . . . . . 369<br />
09902188 . . . . . . . . . . . . . . . . . . . . . . . . . . . 81<br />
09902205 . . . . . . . . . . . . . . . . . . . . . . . . . . 350<br />
09902206 . . . . . . . . . . . . . . . . . . . . . . . . . . 351<br />
09902207 . . . . . . . . . . . . . . . . . . . . . . 228-230<br />
09902218 . . . . . . . . . . . . . . . . . . . . . . . . . . 193<br />
09902219 . . . . . . . . . . . . . . . . . . . . . . . . 13-15<br />
09902225 . . . . . . . . . . . . . . . . . . . . . . . . . . 228<br />
09902236 . . . . . . . . . . . . . . . . . . . . . . . . 13-14<br />
09902239 . . . . . . . . . . . . . . . . . . . . . . . . . . . 20<br />
09902240 . . . . . . . . . . . . . . . . . . . . . . . . 13-14<br />
09902245 . . . . . . . . . . . . . . . . . . . . . . . . . . 353<br />
09902247 . . . . . . . . . . . . . . 135, 226, 228-230<br />
09902473 . . . . . . . . . . . . . . . . . . . . . . . . . . . 18<br />
09903011 . . . . . . . . . . . . . . . . . . . . . . . . . . 370<br />
09903021 . . . . . . . . . . . . . . . . . . . . . . . . . . 230<br />
09903094 . . . . . . . . . . . . . . . . . . 226, 229-230<br />
09903103 . . . . . . . . . . . . . . . . . . . . . . . . . . 223<br />
09903104 . . . . . . . . . . . . . . . . . . . . . . . . . . 223<br />
09903119 . . . . . . . . . . . . . . . . . . . . . . . . . . 205<br />
09903120 . . . . . . . . . . . . . . . . . . . . . . . . . . 205<br />
09903128 . . . . . . . . . . . . . . . . . . . . . . . . . . 155<br />
09903196 . . . . . . . . . . . . . . . . . . . . . . . . . . 355<br />
09903199 . . . . . . . . . . . . . . . . . . . . . . . . . . 223<br />
09903289 . . . . . . . . . . . . . . . . . . . . . . 273, 323<br />
09903392 . . . . . . . . . . . . . . . . . . . 92, 150, 155<br />
09903394 . . . . . . . . . . . . . . . . . . . . . . . . . . . 94<br />
09903395 . . . . . . . . . . . . . . . . . . . . . . . . . . . 94<br />
09903428 . . . . . . . . . . . . . . . . . . . . . . . . . . 226<br />
09903471 . . . . . . . . . . . . . . . . . . . . . . 223, 355<br />
09903606 . . . . . . . . . . . . . . . . . . . . . . . . . . 322<br />
09903610 . . . . . . . . . . . . . . . . . . . . . . . . . . 322<br />
09903615 . . . . . . . . . . . . . . . . . . 242, 273, 322<br />
09903665 . . . . . . . . . . . . . . . . . . . . . . . . . . . 82<br />
09903673 . . . . . . . . . . . . . . . . . . . . . . . . . . . 82<br />
09903700 . . . . . . . . . . . . . . . . . . . . . . . 94, 147<br />
09903739 . . . . . . . . . . . . . . . . . . . . . . . . 92, 94<br />
09903771 . . . . . . . . . . . . . . . . . . . . . . . . . . 318<br />
09903799 . . . . . . . . . . . . . . . . . . . . . . . . . . . 23<br />
09903807 . . . . . . . . . . . . . . . . . . . . . . . . . . 323<br />
09903890 . . . . . . . . . . . . . . . . . . . . . . . . . . 323<br />
09903891 . . . . . . . . . . . . . . . . . . . . . . . . . . 323<br />
09903906 . . . . . . . . . . . . . . . . . . . . . . . . . . 318<br />
09903915 . . . . . . . . . . . . . . . . . . . . . . . . . . . 94<br />
09903980 . . . . . . . . . . . . . . . . . . . . . . . . . . 323<br />
09903981 . . . . . . . . . . . . . . . . . . . . . . . . . . . 94<br />
09903999 . . . . . . . . . . . . . . . . . . . . . . . . . . 226<br />
09904800 . . . . . . . . . . . . . . . . . . . . . . . . . . 325<br />
09904801 . . . . . . . . . . . . . . . . . . . . . . . . . . 325<br />
09904802 . . . . . . . . . . . . . . . . . . . . . . . . . . 325<br />
09904805 . . . . . . . . . . . . . . . . . . . . . . . . . . 325<br />
09904818 . . . . . . . . . . . . . . . . . . . . . . . . . . 326<br />
09904819 . . . . . . . . . . . . . . . . . . . . . . . . . . 326<br />
09904820 . . . . . . . . . . . . . . . . . . . . . . . . . . 326<br />
09904822 . . . . . . . . . . . . . . . . . . . . . . 161, 327<br />
09904823 . . . . . . . . . . . . . . . . . . . . . . 161, 327<br />
09904827 . . . . . . . . . . . . . . . . . . . . . . . . . . 326<br />
09904845 . . . . . . . . . . . . . . . . . . . . . . . . . . 216<br />
09904846 . . . . . . . . . . . . . . . . . . . . . . 193, 216<br />
09904849 . . . . . . . . . . . . . . . . . . . . . . . . . . 321<br />
09904937 . . . . . . . . . . . . . . . . . . . . . . . . . . 327<br />
09904938 . . . . . . . . . . . . . . . . . . . . . . . . . . 326<br />
09904939 . . . . . . . . . . . . . . . . . . . . . . . . . . 326<br />
09904940 . . . . . . . . . . . . . . . . . . . . . . . . . . 326<br />
09904941 . . . . . . . . . . . . . . . . . . . . . . 161, 327<br />
09904942 . . . . . . . . . . . . . . . . . . . . . . . . . . 326<br />
09904943 . . . . . . . . . . . . . . . . . . . . . . . . . . 327<br />
09904947 . . . . . . . . . . . . . . . . . . . . . . . . . . 323<br />
09904953 . . . . . . . . . . . . . . . . . . . . . . . . . . 325<br />
09904955 . . . . . . . . . . . . . . . . . . . . . . . . . . 325<br />
09904956 . . . . . . . . . . . . . . . . . . . . . . . . . . 323<br />
09904962 . . . . . . . . . . . . . . . . . . . . . . . . . . 325<br />
09904963 . . . . . . . . . . . . . . . . . . . . . . . . . . 325<br />
09904974 . . . . . . . . . . . . . . . . . . . . . . . . . . 323<br />
09904991 . . . . . . . . . . . . . . . . . . . 13, 204, 218<br />
09905147 . . . . . . . . . . . . . . . . . . . . . . . . . . 192<br />
09905932 . . . . . . . . . . . . . . . . . . . . . . . . . . 370<br />
09907120 . . . . . . . . . . . . . . . . . . . . . . . . . . . 36<br />
09907122 . . . . . . . . . . . . . . . . . . . . . . . . . . 216<br />
09907126 . . . . . . . . . . . . . . . . . . . . . . 314, 316<br />
09907127 . . . . . . . . . . . . . . . . . . . . . . . . . . 165<br />
09907128 . . . . . . . . . . . . . . . . . . . . . . . . . . 165<br />
09907204 . . . . . . . . . . . . . . . . . . . . . . . . . . . 82<br />
09907222 . . . . . . . . . . . . . . . . . . . . . . . . . . 137<br />
09907233 . . . . . . . . . . . . . . . . . . . . . . . . . . 145<br />
09907236 . . . . . . . . . . . . . . . . . . . . . . . . . . 353<br />
09907281 . . . . . . . . . . . . . . . . . . . . . . . . . . 366<br />
09907324 . . . . . . . . . . . . . . . . . . . . . . 319-320<br />
09907338 . . . . . . . . . . . . . . . . . . . . . . 319-320<br />
09907339 . . . . . . . . . . . . . . . . . . . . . . 319-320<br />
09907345 . . . . . . . . . . . . . . . . . . . . . . 319-320<br />
09907504 . . . . . . . . . . . . . . . . . . . . . . . . . . 348<br />
09907827 . . . . . . . . . . . . . . . . . . . . . . . . . . 132<br />
09907925 . . . . . . . . . . . . . . . . . . . . . . . . . . . 35<br />
09907998 . . . . . . . . . . . . . . . . . . . . . . . . . . . 88<br />
09908134 . . . . . . . . . . . . . . . . . . . . . . 354-355<br />
09908138 . . . . . . . . . . . . . . . 80, 351, 370, 375<br />
09908265 . . . . . . . . . . . . . . . 18, 193, 223-224<br />
09908396 . . . . . . . . . . . . . . . . . . . . . . . . . . 375<br />
09908397 . . . . . . . . . . . . . . . . . . . . . . 370, 375<br />
09908400 . . . . . . . 80, 351, 353, 366, 370, 375<br />
09908467 . . . . . . . . . . . . . . . . . . . . . . 341, 344<br />
09908522 . . . . . . . . . . . . . . . . . . . . . . . . . . 230<br />
09908587 . . . . . . . . . . . . . . . . . . 193, 199, 224<br />
09908825 . . . . . . . . . . . . . . . . . . . . . . . . . . 366<br />
09908851 . . . . . . . . . . . . . . . . . . . . . . . . . . 181<br />
09910148 . . . . . . . . . . . . . . . . . . . . . . . . 13-14<br />
09911186 . . . . . . . . . . . . . . . . . . 356, 360, 362<br />
09911286 . . . . . . . . . . . . . . . . . . . . . . . . 13-14<br />
09912223 . . . . . . . . . . . . . . . . . . . . . . . . . . 133<br />
09920021 . . . . . . . . . . . . . . . . . . . . . . . . . . 230<br />
09920034 . . . . . . . . . . . . . . . . . . . . . . 229-230<br />
09920104 . . . . . . . . . . . . . . . . . . . . . . . 94, 147<br />
09920105 . . . . . . . . . . . . . . . . . . . . . . . 94, 150<br />
09920107 . . . . . . . . . . . . . . . . . . . . . . . . 92, 94<br />
09920118 . . . . . . . . . . . . . . . . . . . . . . 229-230<br />
09920123 . . . . . . . . . . . . . . . . . . . . . . . . . . . 10<br />
09920124 . . . . . . . . . . . . . . . . . . . . . . . . . . . 10<br />
09920127 . . . . . . . . . . . . . . . . . . . . . . . 94, 147<br />
09920140 . . . . . . . . . . . . . . . . . . . . . . . 94, 150<br />
09920141 . . . . . . . . . . . . . . . . . . . . . . . . 92, 94<br />
09920186 . . . . . . . . . . . . . . . . . . . . . . 223, 226<br />
09920262 . . . . . . . . . . . . . . . . . . . . . . 218, 226<br />
09920301 . . . . . . . . . . . . . . . . . . . . . . 150, 155<br />
09920379 . . . . . . . . . . . . . . . . . . . . . . 193, 204<br />
09920381 . . . . . . . . . . . . . . . . . . . . . . . . . . 273<br />
09920382 . . . . . . . . . . . . . . . . . . . . . . . . . . 273<br />
09920391 . . . . . . . . . . . . . . . . . . . . . . . . . . 273<br />
09920404 . . . . . . . . . . . . . . . . . . . . . . . . . . . 81<br />
09920429 . . . . . . . . . . . . . . . . . . . . . . . . . . 273<br />
09920513 . . . . . . . . . . . . . . . . . . . . . . 273, 323<br />
09920515 . . . . . . . . . . . . . . . . . . 197-198, 223<br />
09920516 . . . . . . . . . . . . . . . . . . . . . . . . . . 198<br />
09920517 . . . . . . . . . . . . . . . . . . . . . . . . . . 198<br />
09920518 . . . . . . . . . . . . . . . . . . . . . . 198, 223<br />
09920528 . . . . . . . . . . . . . . . . . . . . . . . . . . 230<br />
09920545 . . . . . . . . . . . . . . . . . . . . . . . . . . 223<br />
09920546 . . . . . . . . . . . . . . . . . . . . . . . . . . 223<br />
09920593 . . . . . . . . . . . . . . . . . . . . . . . . . . 184<br />
09920672 . . . . . . . . . . . . . . . . . . . . . . . . . . 273<br />
09921004 . . . . . . . . . . . . . . . . . . . . . . . . . . 155<br />
09921018 . . . . . . . . . . . . . . . . . . . . . . . . . . 353<br />
09921019 . . . . . . . . . . . . . . . . . . . . . . . . . . 353<br />
09921028 . . . . . . . . . . . . . . . . . . . . . . 228, 230<br />
09921037 . . . . . . . . . . . . . . . . . . . . . . . . . . 242<br />
09921044 . . . . . . . . . . . . . . . . . . . . . . . . 13-14<br />
09921045 . . . . . . . . . . . . . . . . . . . . . . 198, 223<br />
09923012 . . . . . . . . . . . . . . . . . . . . . . . . . . 230<br />
09923031 . . . . . . . . . . . . . . . . . . . . . . . . . . . 89<br />
09923032 . . . . . . . . . . . . . . . . . . . . . . . . . . . 89<br />
09923078 . . . . . . . . . . . . . . . . . . . . . . 132, 137<br />
09923219 . . . . . . . . . . . . . . . . . . . . . . . . . . 273<br />
09923270 . . . . . . . . . . . . . . . . . . . . . . . . . . 273<br />
09923304 . . . . . . . . . . . . . . . . . . . . . . . . . . 273<br />
09923305 . . . . . . . . . . . . . . . . . . . . . . . . . . 273<br />
09923306 . . . . . . . . . . . . . . . . . . . . . . . . . . 273<br />
09923307 . . . . . . . . . . . . . . . . . . . . . . . . . . 273<br />
09923337 . . . . . . . . . . . . . . . . . . . . . . . . . . 243<br />
09923366 . . . . . . . . . . . . . . . . . . . . . . 319-320<br />
09923367 . . . . . . . . . . . . . . . . . . . . . . 319-320<br />
09923448 . . . . . . . . . . . . . . . . . . . . . . . . . . 199<br />
09923454 . . . . . . . . . . . . . . . . . . . . . . . . . . 354<br />
09923464 . . . . . . . . . . . . . . . . . . . . . . . 36, 216<br />
09923490 . . . . . . . . . . . . . . . . . . . . . . . . . . 137<br />
09923491 . . . . . . . . . . . . . . . . . . . . . . . . . . 137<br />
09923492 . . . . . . . . . . . . . . . . . . . . . . . . . . 137<br />
09923518 . . . . . . . . . . . . . . . . . . . . . . . . . . 137<br />
09926070 . . . . . . . . . . . . . . . . . . . . . . . . . . 228<br />
09926083 . . . . . . . . . . . . . . . . . . . . . . . . . . . 18<br />
09934472 . . . . . . . . . . . . . . . . . . . . . . . . . . 137<br />
09934562 . . . . . . . . . . . . . . . . . . . . . . . . . . 137<br />
09935404 . . . . . . . . . . . . . . . . . . . . . . . . . . 144<br />
09936189 . . . . . . . . . . . . . . . . . . . . . . . . . . 316<br />
09936341 . . . . . . . . . . . . . . . . . . . . . . . . . . 137<br />
09936504 . . . . . . . . . . . . . . . . . . . . . . . . . . 316<br />
09936751 . . . . . . . . . . . . . . . . . . . . . . . . . . 315<br />
09937138 . . . . . . . . . . . . . . . . . . . . . . . . . . 375<br />
09937169 . . . . . . . . . . . . . . . . . . . . . . . . . . 321<br />
09938727 . . . . . . . . . . . . . . . . . . . . . . . . . . 314<br />
09938906 . . . . . . . . . . . . . . . . . . . . . . . . . . 315<br />
09938910 . . . . . . . . . . . . . . . . . . . . . . . . . . 321<br />
09938912 . . . . . . . . . . . . . . . . . . . . . . . . . . 273<br />
09938914 . . . . . . . . . . . . . . . . . . . . . . . . . . 314<br />
09940438 . . . . . . . . . . . . . . . . . . . . . . 229-230<br />
09972321 . . . . . . . . . . . . . . . . . . . . . . . . . . 135<br />
09972337 . . . . . . . . . . . . . . . . . . . . . . . . . . 315<br />
09981785 . . . . . . . . . . . . . . . . . . . . . . . . . . 369<br />
09985514 . . . . . . . . . . . . . . . . . . . . . . . . . . 230<br />
09985708 . . . . . . . . . . . . . . . 18, 167, 223-224<br />
09985727 . . . . . . . . . . . . . . . . . . . . . . . . . . 230<br />
Part No. Page Part No. Page Part No. Page<br />
See page 4 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
See page 2 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong>
Index Part Number 09985729 – B0157117<br />
Index<br />
Part Number<br />
410<br />
09985729 . . . . . . . . . . . . . . . . . . . . . . 226, 230<br />
09986072 . . . . . . . . . . . . . . . . . . . . . . . . . . 226<br />
09988015 . . . . . . . . . . . . . . . . . . . . . . . . . . 368<br />
09988017 . . . . . . . . . . . . . . . . . . . . . . . . . . 368<br />
09989859 . . . . . . . . . . . . . . . . . . . . . . . . . . 219<br />
09991413 . . . . . . . . . . . . . . . . . . . . . . 175, 330<br />
09991414 . . . . . . . . . . . . . . . . . . . . . . 175, 330<br />
09991415 . . . . . . . . . . . . . . . . . . . . . . 175, 330<br />
09991416 . . . . . . . . . . . . . . . . . . . . . . 175, 330<br />
09991417 . . . . . . . . . . . . . . . . . . . . . . 175, 330<br />
09991463 . . . . . . . . . . . . . . . . . . . . . . . . . . 137<br />
09992731 . . . . . . . . . . . . . . . . . . . . . . . . . . 219<br />
09995097 . . . . . . . . . . . . . . . . . . . . . . . . . . . 37<br />
09995098 . . . . . . . . . . . . . . . . . . . . . . . . . . 216<br />
09997196 . . . . . . . . . . . . . . . . . . . . . . . . . . 331<br />
10070900 . . . . . . . . . . . . . . . . . . . . . . . . . . 325<br />
10071000 . . . . . . . . . . . . . . . . . . . . . . . . . . 325<br />
10082600 . . . . . . . . . . . . . . . . . . . . . . . . . . 326<br />
20143300 . . . . . . . . . . . . . . . . . . . . . . . . . . 326<br />
25000323 . . . . . . . . . . . . . . . . . . . . . . . . . . 316<br />
26000050 . . . . . . . . . . . . . . . . . . . . . . . . . . 316<br />
29000078 . . . . . . . . . . . . . . . . . . . . . . . . . . 316<br />
29000544 . . . . . . . . . . . . . . . . . . . . . . . . . . 316<br />
29000545 . . . . . . . . . . . . . . . . . . . . . . . . . . 316<br />
41000013 . . . . . . . . . . . . . . . . . . . . . . . . . . 326<br />
51000634 . . . . . . . . . . . . . . . . . . . . . . . . . . 245<br />
51000635 . . . . . . . . . . . . . . . . . . . . . . . . . . 245<br />
51000636 . . . . . . . . . . . . . . . . . . . . . . . . . . 245<br />
51000637 . . . . . . . . . . . . . . . . . . . . . . . . . . 245<br />
51000638 . . . . . . . . . . . . . . . . . . . . . . . . . . 245<br />
51000639 . . . . . . . . . . . . . . . . . . . . . . . . . . 245<br />
51001135 . . . . . . . . . . . . . . . . . . . . . . . . . . 248<br />
51001137 . . . . . . . . . . . . . . . . . . . . . . . . . . 248<br />
51001140 . . . . . . . . . . . . . . . . . . . . . . . . . . 248<br />
51001141 . . . . . . . . . . . . . . . . . . . . . . . . . . 248<br />
51001144 . . . . . . . . . . . . . . . . . . . . . . . . . . 258<br />
51001148 . . . . . . . . . . . . . . . . . . . . . . . . . . 258<br />
51001149 . . . . . . . . . . . . . . . . . . . . . . . . . . 258<br />
51001152 . . . . . . . . . . . . . . . . . . . . . . . . . . 258<br />
51001188 . . . . . . . . . . . . . . . . . . . . . . . . . . 248<br />
51001324 . . . . . . . . . . . . . . . . . . . . . . . . . . 248<br />
51001325 . . . . . . . . . . . . . . . . . . . . . . . . . . 248<br />
51001326 . . . . . . . . . . . . . . . . . . . . . . . . . . 248<br />
51001327 . . . . . . . . . . . . . . . . . . . . . . . . . . 248<br />
51001328 . . . . . . . . . . . . . . . . . . . . . . . . . . 248<br />
51001329 . . . . . . . . . . . . . . . . . . . . . . . . . . 248<br />
51002592 . . . . . . . . . . . . . . . . . . . . . . . . . . 259<br />
51002593 . . . . . . . . . . . . . . . . . . . . . . . . . . 259<br />
51004599 . . . . . . . . . . . . . . . . . . . . . . . . . . 258<br />
51010817 . . . . . . . . . . . . . . . . . . . . . . . . . . 245<br />
51012725 . . . . . . . . . . . . . . . . . . . . . . . . . . 245<br />
52001539 . . . . . . . . . . . . . . . . . . . . . . . . . . 249<br />
52001543 . . . . . . . . . . . . . . . . . . . . . . . . . . 249<br />
54019985 . . . . . . . . . . . . . . . . . . . . . . . . . . 159<br />
60000186 . . . . . . . . . . . . . . . . . . . . . . . . . . 316<br />
60000366 . . . . . . . . . . . . . . . . . . . . . . . . . . 316<br />
65105001 . . . . . . . . . . . . . . . . . . . . . . 177, 331<br />
65105102 . . . . . . . . . . . . . . . . . . . . . . 177, 331<br />
65105204 . . . . . . . . . . . . . . . . . . . . . . 177, 331<br />
65105408 . . . . . . . . . . . . . . . . . . . . . . 177, 331<br />
65204501 . . . . . . . . . . . . . . . . . . . . . . . . . . 177<br />
65605810 . . . . . . . . . . . . . . . . . . . . . . . . . . 177<br />
65607610 . . . . . . . . . . . . . . . . . . . . . . . . . . 177<br />
65607625 . . . . . . . . . . . . . . . . . . . . . . . . . . 177<br />
65609010 . . . . . . . . . . . . . . . . . . . . . . . . . . 177<br />
65609025 . . . . . . . . . . . . . . . . . . . . . . . . . . 177<br />
72000008 . . . . . . . . . . . . . . . . . . . . . . . . . . 316<br />
B0008754 . . . . . . . . . . . . . . . . . . . . . . . . . . 400<br />
B0017041 . . . . . . . . . . . . . . . . . . . . . . . . . . 399<br />
B0017047 . . . . . . . . . . . . . . . . . . . . . . . . . . 399<br />
B0017052 . . . . . . . . . . . . . . . . . . . . . . . . . . 399<br />
B0017054 . . . . . . . . . . . . . . . . . . . . . . . . . . 399<br />
B0017057 . . . . . . . . . . . . . . . . . . . . . . . . . . 399<br />
B0017059 . . . . . . . . . . . . . . . . . . . . . . . . . . 400<br />
B0017072 . . . . . . . . . . . . . . . . . . . . . . . . . . 399<br />
B0017998 . . . . . . . . . . . . . . . . . . . . . 10, 12, 25<br />
B0018283 . . . . . . . . . . . . . . . . . 22, 25-26, 226<br />
B0022087 . . . . . . . . . . . . . . . . . . . . . . . . . . 399<br />
B0022088 . . . . . . . . . . . . . . . . . . . . . . . . . . 399<br />
B0023363 . . . . . . . . . . . . . . . . . . . . . . . . . . 399<br />
B0023365 . . . . . . . . . . . . . . . . . . . . . . . . . . 399<br />
B0023491 . . . . . . . . . . . . . . . . . . . . . . . . . . 400<br />
B0023492 . . . . . . . . . . . . . . . . . . . . . . . . . . 400<br />
B0029792 . . . . . . . . . . . . . . . . . 10, 12, 25, 224<br />
B0029796 . . . . . . . . . . . . . . . . . . . . . . . . . . . 27<br />
B0041693 . . . . . . . . . . . . . . . . . . . . . . . . . . 399<br />
B0041695 . . . . . . . . . . . . . . . . . . . . . . . . . . 400<br />
B0041696 . . . . . . . . . . . . . . . . . . . . . . . . . . 399<br />
B0045095 . . . . . . . . . . . . . . . . . . . . . . . . . . . 20<br />
B0045472 . . . . . . . . . . . . . . . . . . . . . . . . . . . 25<br />
B0046948 . . . . . . . . . . . . . . . . . . . . . . . . . . . 22<br />
B0047209 . . . . . . . . . . . . . . . . . . . . . . . . . . . 33<br />
B0048139 . . . . . . . . . . . . . . . . . . . . . . . . . 8, 25<br />
B0055900 . . . . . . . . . . . . . . . . . . . . . . . . . . . 11<br />
B0057334 . . . . . . . . . . . . . . . . . . . . . . . . . . . 20<br />
B0057336 . . . . . . . . . . . . . . . . . . . . . . . . . . . 20<br />
B0057408 . . . . . . . . . . . . . . . . . . . . . . . . . . . 20<br />
B0057409 . . . . . . . . . . . . . . . . . . . . . . . . . . . 20<br />
B0057410 . . . . . . . . . . . . . . . . . . . . . . . . . . . 20<br />
B0057761 . . . . . . . . . . . . . . . . . . . . . . . . . . . 20<br />
B0062666 . . . . . . . . . . . . . . . . . . . . . . . . . . 400<br />
B0066549 . . . . . . . . . . . . . . . . 22, 33, 219, 349<br />
B0070126 . . . . . . . . . . . . . . . . . . . . . . . . . . . 26<br />
B0070699 . . . . . . . . . . . . . . . . . . . . . . . . . . . 32<br />
B0071145 . . . . . . . . . . . . . . . . . . . . . . . . . . . 33<br />
B0071519 . . . . . . . . . . . . . . . . . . . . . . . . . . 384<br />
B0076786 . . . . . . . . . . . . . . . . . . . . . . . . . . 400<br />
B0080112 . . . . . . . . . . . . . . . . . . . . . . . . . . . 31<br />
B0080171 . . . . . . . . . . . . . . . . . . . . . . . . . . 386<br />
B0080259 . . . . . . . . . . . . . . . . . . . . . . . . . . . 32<br />
B0080333 . . . . . . . . . . . . . . . . . . . . . . . . . . . 10<br />
B0080819 . . . . . . . . . . . . . . . . . . . . . . . . . . 386<br />
B0080821 . . . . . . . . . . . . . . . . . . . . . . . . . . 388<br />
B0080822 . . . . . . . . . . . . . . . . . . . . . . . . . . 389<br />
B0080850 . . . . . . . . . . . . . . . . . . . . . . . . . . . 33<br />
B0082539 . . . . . . . . . . . . . . . . . . . . . . . . . . 388<br />
B0084183 . . . . . . . . . . . . . . . . . . . . . . . . . . 383<br />
B0086142 . . . . . . . . . . . . . . . . . . . . . . . . . . . 12<br />
B0086703 . . . . . . . . . . . . . . . . . . . . . . . . . . 384<br />
B0087056 . . . . . . . . . . . . . . . . . . . . . . . . . . . 11<br />
B0087354 . . . . . . . . . . . . . . . . . . . . . . . . . . . 49<br />
B0087600 . . . . . . . . . . . . . . . . . . . . . . . . . . . 11<br />
B0089439 . . . . . . . . . . . . . . . . . . . . . . . . . . 389<br />
B0091504 . . . . . . . . . . . . . . . . . . . . . . . 32, 193<br />
B0091906 . . . . . . . . . . . . . . . . . . . . . . . . . . 397<br />
B0092456 . . . . . . . . . . . . . . . . . . . . . . . . . . 273<br />
B0092468 . . . . . . . . . . . . . . . . . . . . . . . . . . 273<br />
B0094032 . . . . . . . . . . . . . . . . . . . . . . . . . . . 49<br />
B0094138 . . . . . . . . . . . . . . . . . . . . . . . . . . . 49<br />
B0094140 . . . . . . . . . . . . . . . . . . . . . . . . . . . 49<br />
B0094321 . . . . . . . . . . . . . . . . . . . . . . . . . . . 49<br />
B0094404 . . . . . . . . . . . . . . . . . . . . . . . . . . 400<br />
B0094413 . . . . . . . . . . . . . . . . . . . . . . . . . . . 49<br />
B0094415 . . . . . . . . . . . . . . . . . . . . . . . . . . . 49<br />
B0097693 . . . . . . . . . . . . . . . . . . . . . . . . . . . 49<br />
B0097694 . . . . . . . . . . . . . . . . . . . . . . . . . . . 49<br />
B0098258 . . . . . . . . . . . . . . . . . . . . . . . . . . . 31<br />
B0098452 . . . . . . . . . . . . . . . . . . . . . . . . . . . 49<br />
B0098453 . . . . . . . . . . . . . . . . . . . . . . . . . . . 49<br />
B0098640 . . . . . . . . . . . . . . . . . . . . . . . . . . . 49<br />
B0098799 . . . . . . . . . . . . . . . . . . . . . . . . . . 400<br />
B0098800 . . . . . . . . . . . . . . . . . . . . . . . . . . 400<br />
B0101045 . . . . . . . . . . . . . . . . . . . . . . . . . . . 11<br />
B0101161 . . . . . . . . . . . . . . . . . . . . . . . . . . . 12<br />
B0101164 . . . . . . . . . . . . . . . . . . . . . . . . . . . 12<br />
B0102332 . . . . . . . . . . . . . . . . . . . . . . . . . . . 12<br />
B0102949 . . . . . . . . . . . . . . . . . . . . . . . . . . . 15<br />
B0103037 . . . . . . . . . . . . . . . . . . . . . . . . . . . 12<br />
B0104236 . . . . . . . . . . . . . . . . . . . . . . . . . . 148<br />
B0104239 . . . . . . . . . . . . . . . . . . . . . . . . . . 148<br />
B0104240 . . . . . . . . . . . . . . . . . . . . . . . . . . 148<br />
B0104241 . . . . . . . . . . . . . . . . . . . . . . . . . . 148<br />
B0104242 . . . . . . . . . . . . . . . . . . . . . . . . . . 148<br />
B0104243 . . . . . . . . . . . . . . . . . . . . . . . . . . 148<br />
B0104244 . . . . . . . . . . . . . . . . . . . . . . . . . . 148<br />
B0104281 . . . . . . . . . . . . . . . . . . . . . . . . . . . 12<br />
B0104342 . . . . . . . . . . . . . . . . . . . . . . . . . . . 33<br />
B0104987 . . . . . . . . . . . . . . . . . . . . . . . . . . . 12<br />
B0105111 . . . . . . . . . . . . . . . . . . . . . . . . . . 193<br />
B0105197 . . . . . . . . . . . . . . . . . . . . . . . . . . . 32<br />
B0105973 . . . . . . . . . . . . . . . . . . . . . . . 11, 273<br />
B0105974 . . . . . . . . . . . . . . . . . . . . . . . 11, 273<br />
B0107592 . . . . . . . . . . . . . . . . . . . . . . . . . . 399<br />
B0107593 . . . . . . . . . . . . . . . . . . . . . . . . . . 399<br />
B0109322 . . . . . . . . . . . . . . . . . . . . . . . . . . . 32<br />
B0109324 . . . . . . . . . . . . . . . . . . . . . . . . . . . 31<br />
B0109944 . . . . . . . . . . . . . . . . . . . . . . . . . . 383<br />
B0114620 . . . . . . . . . . . . . . . . . . . . . . . . . . 397<br />
B0115576 . . . . . . . . . . . . . . . . . . . . . . . . . . . 33<br />
B0116823 . . . . . . . . . . . . . . . . . . . . . . . . . . . 31<br />
B0119079 . . . . . . . . . . . . . . . . . . . . . . . . . . . 11<br />
B0120242 . . . . . . . . . . . . . . . . . . . . . . . . . . . 31<br />
B0121084 . . . . . . . . . . . . . . . . . . . . . . . . . . 273<br />
B0127014 . . . . . . . . . . . . . . . . . . . . . . . . . . . 45<br />
B0127431 . . . . . . . . . . . . . . . . . . . . . . . . . . . 31<br />
B0128495 . . . . . . . . . . . . . . . . . . . . . . . . . . . 31<br />
B0129258 . . . . . . . . . . . . . . . . . . . . . . . . . . . 12<br />
B0129303 . . . . . . . . . . . . . . . . . . . . . . . . . . . 11<br />
B0129926 . . . . . . . . . . . . . . . . . . . . . . . . . . . 15<br />
B0131186 . . . . . . . . . . . . . . . . . . . . . . . . . . 399<br />
B0131385 . . . . . . . . . . . . . . . . . . . . . . . . . . 147<br />
B0131410 . . . . . . . . . . . . . . . . . . . . . . . . . . 145<br />
B0132799 . . . . . . . . . . . . . . . . . . . . . . . . . . . 12<br />
B0133956 . . . . . . . . . . . . . . . . . . . . . . . . . . 273<br />
B0135485 . . . . . . . . . . . . . . . . . . . . . . . . . . 145<br />
B0135653 . . . . . . . . . . . . . . . . . . . . . . . 32, 193<br />
B0137111 . . . . . . . . . . . . . . . . . . . . . . . . . . . 32<br />
B0137112 . . . . . . . . . . . . . . . . . . . . . . . . . . . 31<br />
B0139005 . . . . . . . . . . . . . . . . . . . . . . . . . . 344<br />
B0139120 . . . . . . . . . . . . . . . . . . . . . . . . . . 345<br />
B0139122 . . . . . . . . . . . . . . . . . . . . . . . . . . 345<br />
B0139997 . . . . . . . . . . . . . . . . . . . . . . . . . . 193<br />
B0142511 . . . . . . . . . . . . . . . . . . . . . . . . . . 345<br />
B0142512 . . . . . . . . . . . . . . . . . . . . . . . . . . 345<br />
B0143003 . . . . . . . . . . . . . . . . . . . . . . 338-339<br />
B0143015 . . . . . . . . . . . . . . . . . . . . . . 338-339<br />
B0143016 . . . . . . . . . . . . . . . . . . . . . . 338-339<br />
B0143017 . . . . . . . . . . . . . . . . . . . . . . 338-339<br />
B0143018 . . . . . . . . . . . . . . . . . . . . . . . . . . 338<br />
B0143019 . . . . . . . . . . . . . . . . . . . . . . . . . . 338<br />
B0143263 . . . . . . . . . . . . . . . . . . . . . . . . . . 345<br />
B0144169 . . . . . . . . . . . . . . . . . . . . . . . . . . 147<br />
B0147449 . . . . . . . . . . . . . . . . . . . . . . . . . . 145<br />
B0148615 . . . . . . . . . . . . . . . . . . . . . . . . . . . 45<br />
B0148651 . . . . . . . . . . . . . . . . . . . . . . . . . . . 20<br />
B0151573 . . . . . . . . . . . . . . . . . . . . . . . . . . . 15<br />
B0151579 . . . . . . . . . . . . . . . . . . . . . . . . . . . 15<br />
B0151697 . . . . . . . . . . . . . . . . . . . . . . . . . . . 15<br />
B0151737 . . . . . . . . . . . . . . . . . . . . . . . . . . 145<br />
B0152456 . . . . . . . . . . . . . . . . . . . . . . . . . . . 20<br />
B0152471 . . . . . . . . . . . . . . . . . . . . . . . . . . 389<br />
B0153250 . . . . . . . . . . . . . . . . . . . . . . . . . . . 15<br />
B0155481 . . . . . . . . . . . . . . . . . . . . . . . . . . 193<br />
B0155546 . . . . . . . . . . . . . . . . . . . . . . . . . . . 15<br />
B0156094 . . . . . . . . . . . . . . . . . . . . . . . . . . . 44<br />
B0157117 . . . . . . . . . . . . . . . . . . . . . . . . . . . 15<br />
Part No. Page Part No. Page Part No. Page
B0158598 – B0509561 Part Number Index<br />
Index<br />
Part Number<br />
411<br />
B0158598 . . . . . . . . . . . . . . . . . . . . . . . . . . . 15<br />
B0158616 . . . . . . . . . . . . . . . . . . . . . . . . . . . 15<br />
B0158690 . . . . . . . . . . . . . . . . . . . . . . . . . . . 15<br />
B0159356 . . . . . . . . . . . . . . . . . . . . . . . . . . 148<br />
B0159357 . . . . . . . . . . . . . . . . . . . . . . . . . . 148<br />
B0160697 . . . . . . . . . . . . . . . . . . . . . . . . . . . 15<br />
B0160917 . . . . . . . . . . . . . . . . . . . . . . . . . . 397<br />
B0162668 . . . . . . . . . . . . . . . . . . . . . . . . . . . 15<br />
B0162669 . . . . . . . . . . . . . . . . . . . . . . . . . . . 15<br />
B0162671 . . . . . . . . . . . . . . . . . . . . . . . . . . . 15<br />
B0162836 . . . . . . . . . . . . . . . . . . . . . . . . . . 273<br />
B0165332 . . . . . . . . . . . . . . . . . . . . . . . . . . . 19<br />
B0166502 . . . . . . . . . . . . . . . . . . . . . . . . . . . 20<br />
B0166503 . . . . . . . . . . . . . . . . . . . . . . . . . . . 17<br />
B0166505 . . . . . . . . . . . . . . . . . . . . . . . . . . . 20<br />
B0166506 . . . . . . . . . . . . . . . . . . . . . . . . . . . 20<br />
B0166507 . . . . . . . . . . . . . . . . . . . . . . . . . . . 20<br />
B0169319 . . . . . . . . . . . . . . . . . . . . . . 338-339<br />
B0169320 . . . . . . . . . . . . . . . . . . . . . . 338-339<br />
B0169321 . . . . . . . . . . . . . . . . . . . . . . 338-339<br />
B0170873 . . . . . . . . . . . . . . . . . . . . . . . . . . 273<br />
B0170875 . . . . . . . . . . . . . . . . . . . . . . . . . . 273<br />
B0173404 . . . . . . . . . . . . . . . . . . . . . . . . . . . 15<br />
B0174378 . . . . . . . . . . . . . . . . . . . . . 15, 18-19<br />
B0174379 . . . . . . . . . . . . . . . . . . . . . . . . . . . 15<br />
B0174380 . . . . . . . . . . . . . . . . . . . . . . . . . . . 15<br />
B0180361 . . . . . . . . . . . . . . . . . . . . . . . . . . . 31<br />
B0180363 . . . . . . . . . . . . . . . . . . . . . . . . . . . 31<br />
B0181091 . . . . . . . . . . . . . . . . . . . . . . . . . . 341<br />
B0181354 . . . . . . . . . . . . . . . . . . . . . . . . . . . 25<br />
B0181576 . . . . . . . . . . . . . . . . . . . . . . . . . . 349<br />
B0181842 . . . . . . . . . . . . . . . . . . . . . . . . . . . 15<br />
B0182864 . . . . . . . . . . . . . . . . . . . . . . . . . . 344<br />
B0182901 . . . . . . . . . . . . . . . . . . . . . . . . . . 340<br />
B0182902 . . . . . . . . . . . . . . . . . . . . . . . . . . 340<br />
B0182903 . . . . . . . . . . . . . . . . . . . . . . . . . . 340<br />
B0182981 . . . . . . . . . . . . . . . . . . . . . . . . . . 345<br />
B0184142 . . . . . . . . . . . . . . . . . . . . . . . . . . 143<br />
B0185163 . . . . . . . . . . . . . . . . . . . . . . . . . . 389<br />
B0185210 . . . . . . . . . . . . . . . . . . . . . . . . . . 387<br />
B0185227 . . . . . . . . . . . . . . . . . . . . . . . . . . 386<br />
B0185259 . . . . . . . . . . . . . . . . . . . . . . . . . . 273<br />
B0185480 . . . . . . . . . . . . . . . . . . . . . . . . . . 273<br />
B0186924 . . . . . . . . . . . . . . . . . . . . . . . . . . 349<br />
B0187028 . . . . . . . . . . . . . . . . . . . . . . . . . . 386<br />
B0187258 . . . . . . . . . . . . . . . . . . . . . . . . . . . 22<br />
B0190001 . . . . . . . . . . . . . . . . . . . . . . . . . . . 15<br />
B0190634 . . . . . . . . . . . . . . . . . . . . . 32, 35, 67<br />
B0190635 . . . . . . . . . . . . . . . . . . . . . 32, 35, 67<br />
B0190672 . . . . . . . . . . . . . . . . . . . . . . . . 15, 19<br />
B0191058 . . . . . . . . . . . . . . . . . . . . . 23, 25, 28<br />
B0191059 . . . . . . . . . . . . . . . . . . . . . 23, 25, 28<br />
B0191060 . . . . . . . . . . . . . . . . . . . . . . . . . 9, 25<br />
B0191090 . . . . . . . . . . . . . . . . . . . . . . . . . . . 26<br />
B0191766 . . . . . . . . . . . . . . . . . . . . . . . . . . 383<br />
B0193160 . . . . . . . . . . . . . . . . . . . . . . . . 23, 25<br />
B0193161 . . . . . . . . . . . . . . . . . . . . . . . . 25, 28<br />
B0193233 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8<br />
B0193234 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8<br />
B0193235 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8<br />
B0193342 . . . . . . . . . . . . . . . . . . . . . 23-24, 28<br />
B0193766 . . . . . . . . . . . . . . . . . . . . . . . . . . 273<br />
B0193768 . . . . . . . . . . . . . . . . . . . . . . . . . . 389<br />
B0193772 . . . . . . . . . . . . . . . . . . . . . . . . . . . 22<br />
B0193780 . . . . . . . . . . . . . . . . . . . . . . . . . . 273<br />
B0193793 . . . . . . . . . . . . . . . . . . . . . . . . . . . 26<br />
B0193873 . . . . . . . . . . . . . . . . . . . . . . . . . . . 24<br />
B0194048 . . . . . . . . . . . . . . . . . . . . . . . . . . . 25<br />
B0194049 . . . . . . . . . . . . . . . . . . . . . . . . . . . 25<br />
B0196704 . . . . . . . . . . . . . . . . . . . . . . . . 24, 28<br />
B0196850 . . . . . . . . . . . . . . . . . . . . . . . . 24, 28<br />
B0196857 . . . . . . . . . . . . . . . . . . . . . . . . . . . 24<br />
B0196858 . . . . . . . . . . . . . . . . . . . . . . 341, 349<br />
B0196882 . . . . . . . . . . . . . . . . . . . . . . . . . . . 24<br />
B0196912 . . . . . . . . . . . . . . . . . . . . . . . . . . 380<br />
B0197336 . . . . . . . . . . . . . . . . . . . . . . . . . . 145<br />
B0198005 . . . . . . . . . . . . . . . . . . . . . . . . . . . 35<br />
B0198016 . . . . . . . . . . . . . . . . . . . . . . . . . . 273<br />
B0198017 . . . . . . . . . . . . . . . . . . . . . . . . . . 273<br />
B0198023 . . . . . . . . . . . . . . . . . . . . . . . . . . 383<br />
B0198030 . . . . . . . . . . . . . . . . . . . . . . 341, 349<br />
B0198072 . . . . . . . . . . . . . . . . . . . . . . . . . . . 35<br />
B0198093 . . . . . . . . . . . . . . . . . . . . . . . . . . . 80<br />
B0198097 . . . . . . . . . . . . . . . . . . . . . . . . 23, 25<br />
B0198099 . . . . . . . . . . . . . . . . . . . . . . . . 25-26<br />
B0198100 . . . . . . . . . . . . . . . . . . . . . . . . 25-26<br />
B0198104 . . . . . . . . . . . . . . . . . . . . . . . . . . . 26<br />
B0198110 . . . . . . . . . . . . . . . . . . . . . . . . . . 147<br />
B0198111 . . . . . . . . . . . . . . . . . . . . . . . . 23, 26<br />
B0198180 . . . . . . . . . . . . . . . . . . . . . . . . . . 273<br />
B0198201 . . . . . . . . . . . . . . . . . . . . . . . . 24, 26<br />
B0199034 . . . . . . . . . . . . . . . . . . . . . . . 25, 383<br />
B0199035 . . . . . . . . . . . . . . . . . . . . . . . . . . . 24<br />
B0199233 . . . . . . . . . . . . . . . . . . . . . . . . . . . 24<br />
B0199379 . . . . . . . . . . . . . . . . . . . . . . . . . . 346<br />
B0500695 . . . . . . . . . . . . . . . . . . . . . . . . . . . 28<br />
B0500722 . . . . . . . . . . . . . . . . . . . . . . . . . . 346<br />
B0500724 . . . . . . . . . . . . . . . . . . . . . . . . . . 346<br />
B0500748 . . . . . . . . . . . . . . . . . . . . . . . . . . . 34<br />
B0500778 . . . . . . . . . . . . . . . . . . . . . . . . . . 144<br />
B0500833 . . . . . . . . . . . . . . . . . . . . . . . . . . 147<br />
B0500843 . . . . . . . . . . . . . . . . . . . . . . . . . . 145<br />
B0500952 . . . . . . . . . . . . . . . . . . . . . . . . . . 389<br />
B0500959 . . . . . . . . . . . . . . . . . . . . . . . . . . 147<br />
B0500987 . . . . . . . . . . . . . . . . . . . . . . . . . . 147<br />
B0501000 . . . . . . . . . . . . . . . . . . . . . . . . 25-26<br />
B0501022 . . . . . . . . . . . . . . . . . . . . . . . . . . . 17<br />
B0501025 . . . . . . . . . . . . . . . . . . . . . . . . . . . 17<br />
B0501026 . . . . . . . . . . . . . . . . . . . . . . . . . . . 17<br />
B0501029 . . . . . . . . . . . . . . . . . . . . . . . . . . . 17<br />
B0501056 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8<br />
B0501236 . . . . . . . . . . . . . . . . . . . . . . . . . . . 35<br />
B0501252 . . . . . . . . . . . . . . . . . . . . . . . . . . . 37<br />
B0501258 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8<br />
B0501282 . . . . . . . . . . . . . . . . . . . . . . . . . . 382<br />
B0501315 . . . . . . . . . . . . . . . . . . . . . . . . . . . 24<br />
B0501580 . . . . . . . . . . . . . . . . . . . . . . . . 24, 28<br />
B0501594 . . . . . . . . . . . . . . . . . . . . . . . . 25, 28<br />
B0501595 . . . . . . . . . . . . . . . . . . . . . . . . 25, 28<br />
B0501696 . . . . . . . . . . . . . . . . . . . . . . . . . . . 37<br />
B0502195 . . . . . . . . . . . . . . . . . . . . . . . . . . . 55<br />
B0502196 . . . . . . . . . . . . . . . . . . . . . . . . . . . 55<br />
B0502197 . . . . . . . . . . . . . . . . . . . . . . . . 53, 55<br />
B0502201 . . . . . . . . . . . . . . . . . . . . . . . . . . . 54<br />
B0502202 . . . . . . . . . . . . . . . . . . . . . . . . . . . 54<br />
B0502203 . . . . . . . . . . . . . . . . . . . . . . . . . . . 54<br />
B0502204 . . . . . . . . . . . . . . . . . . . . . . . . . . . 54<br />
B0502706 . . . . . . . . . . . . . . . . . . . . . . . . 26, 37<br />
B0502921 . . . . . . . . . . . . . . . . . . . . . . . . . . . 25<br />
B0502923 . . . . . . . . . . . . . . . . . . . . . . . . . . . 25<br />
B0502924 . . . . . . . . . . . . . . . . . . . . . . . . . . . 25<br />
B0502925 . . . . . . . . . . . . . . . . . . . . . . . . . . . 25<br />
B0503956 . . . . . . . . . . . . . . . . . . . . . . . . . . 147<br />
B0504033 . . . . . . . . . . . . . . . . . . . . . . . . . . . 34<br />
B0504035 . . . . . . . . . . . . . . . . . . . . . . . . . . . 34<br />
B0504036 . . . . . . . . . . . . . . . . . . . . . . . . . . . 34<br />
B0504047 . . . . . . . . . . . . . . . . . . . . . . . 28, 188<br />
B0504048 . . . . . . . . . . . . . . . . . . . . . . . 28, 188<br />
B0505071 . . . . . . . . . . . . . . . . . . . . . . . . . . 388<br />
B0505086 . . . . . . . . . . . . . . . . . . . . . . . . 17-19<br />
B0505266 . . . . . . . . . . . . . . . . . . . . . . . . . . 146<br />
B0505268 . . . . . . . . . . . . . . . . . . . . . . . . . . 145<br />
B0505271 . . . . . . . . . . . . . . . . . . . . . . . . . . 144<br />
B0505284 . . . . . . . . . . . . . . . . . . . . . . . . . . 382<br />
B0505326 . . . . . . . . . . . . . . . . . . . . . . . . . . . 26<br />
B0505475 . . . . . . . . . . . . . . . . . . . . . . . . . . 143<br />
B0505480 . . . . . . . . . . . . . . . . . . . . . . . . 17, 19<br />
B0505530 . . . . . . . . . . . . . . . . . . . . . . . . . . 382<br />
B0505540 . . . . . . . . . . . . . . . . . . . . . . . . . . 188<br />
B0505588 . . . . . . . . . . . . . . . . . . . . . . . . . . . 17<br />
B0505589 . . . . . . . . . . . . . . . . . . . . . . . . . . . 17<br />
B0505590 . . . . . . . . . . . . . . . . . . . . . . . . 17, 19<br />
B0505601 . . . . . . . . . . . . . . . . . . . . . . . . . . 148<br />
B0505650 . . . . . . . . . . . . . . . . . . . . . . . . . . . 23<br />
B0505677 . . . . . . . . . . . . . . . . . . . . . . 270, 273<br />
B0505866 . . . . . . . . . . . . . . . . . . . . . . . . . . 383<br />
B0505889 . . . . . . . . . . . . . . . . . . . . . . . . . . 146<br />
B0505962 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9<br />
B0505978 . . . . . . . . . . . . . . . . . . . . . . . . . . 146<br />
B0506058 . . . . . . . . . . . . . . . . . . . . . . . . 25, 28<br />
B0506060 . . . . . . . . . . . . . . . . . . . . . . . . . . . 25<br />
B0506539 . . . . . . . . . . . . . . . . . . . . . . . . . . 146<br />
B0506592 . . . . . . . . . . . . . . . . . . . . . . . . . . 273<br />
B0506603 . . . . . . . . . . . . . . . . . . . . . . . . . . 146<br />
B0506666 . . . . . . . . . . . . . . . . . . . . . . . . . . . 17<br />
B0506668 . . . . . . . . . . . . . . . . . . . . . . . . . . . 17<br />
B0506716 . . . . . . . . . . . . . . . . . . . . . . . . . . . 24<br />
B0506722 . . . . . . . . . . . . . . . . . . . . . . . . . . . 35<br />
B0507020 . . . . . . . . . . . . . . . . . . . . . . . . . . . 25<br />
B0507021 . . . . . . . . . . . . . . . . . . . . . . . . . . . 25<br />
B0507226 . . . . . . . . . . . . . . . . . . . . . . . . . . . 67<br />
B0507355 . . . . . . . . . . . . . . . . . . . . . . . . . . 386<br />
B0507403 . . . . . . . . . . . . . . . . . . . . . . . . . . 399<br />
B0507447 . . . . . . . . . . . . . . . . . . . . . . . . . . 399<br />
B0507451 . . . . . . . . . . . . . . . . . . . . . . . . . . 399<br />
B0507486 . . . . . . . . . . . . . . . . . . . . . . . . . . . 22<br />
B0507487 . . . . . . . . . . . . . . . . . . . . . . . . . . . 22<br />
B0507692 . . . . . . . . . . . . . . . . . . . . . . . . 25, 28<br />
B0507708 . . . . . . . . . . . . . . . . . . . . . . . . . . . 25<br />
B0507777 . . . . . . . . . . . . . . . . . . . . . . . . . . . 26<br />
B0507779 . . . . . . . . . . . . . . . . . . . . . . . . . . . 26<br />
B0507791 . . . . . . . . . . . . . . . . . . . . . . . . . . . 23<br />
B0507792 . . . . . . . . . . . . . . . . . . . . . . . . . . . 23<br />
B0507805 . . . . . . . . . . . . . . . . . . . . . . . . . . 395<br />
B0507914 . . . . . . . . . . . . . . . . . . . . . . . . 23, 28<br />
B0507918 . . . . . . . . . . . . . . . . . . . . . . . . . . . 24<br />
B0507919 . . . . . . . . . . . . . . . . . . . . . . . . . 8, 24<br />
B0507920 . . . . . . . . . . . . . . . . . . . . . . . . . . . 24<br />
B0507921 . . . . . . . . . . . . . . . . . . . . . . . . . . . 24<br />
B0507942 . . . . . . . . . . . . . . . . . . . . . . . . . . 146<br />
B0507944 . . . . . . . . . . . . . . . . . . . . . . . . . . 146<br />
B0507949 . . . . . . . . . . . . . . . . . . . . . . . . . . . 24<br />
B0507957 . . . . . . . . . . . . . . . . . . . . . . . . 22-23<br />
B0507959 . . . . . . . . . . . . . . . . . . . . . . . . . . . 22<br />
B0507960 . . . . . . . . . . . . . . . . . . . . . . . . . . . 22<br />
B0507962 . . . . . . . . . . . . . . . . . . . . . . . . . . . 22<br />
B0508306 . . . . . . . . . . . . . . . . . . . . . . . . . . . 22<br />
B0508310 . . . . . . . . . . . . . . . . . . . . . . . . . . . 25<br />
B0508371 . . . . . . . . . . . . . . . . . . . . . . . . . . 193<br />
B0508373 . . . . . . . . . . . . . . . . . . . . . . . . . . 193<br />
B0508374 . . . . . . . . . . . . . . . . . . . . . . . . . . 193<br />
B0508520 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8<br />
B0508521 . . . . . . . . . . . . . . . . . . . . . . . . . . 146<br />
B0508593 . . . . . . . . . . . . . . . . . . . . . . . . . . 188<br />
B0508594 . . . . . . . . . . . . . . . . . . . . . . . . . . . 23<br />
B0508738 . . . . . . . . . . . . . . . . . . . . . . . . . . 146<br />
B0508836 . . . . . . . . . . . . . . . . . . . . . . . . . . . 35<br />
B0508901 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8<br />
B0508902 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8<br />
B0509065 . . . . . . . . . . . . . . . . . . . . . . . . . . . 37<br />
B0509095 . . . . . . . . . . . . . . . . . . . . . . . . 23, 28<br />
B0509479 . . . . . . . . . . . . . . . . . . . . . . . . . . . 22<br />
B0509546 . . . . . . . . . . . . . . . . . . . . . . . . . . 380<br />
B0509554 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8<br />
B0509555 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8<br />
B0509561 . . . . . . . . . . . . . . . . . . . . . . . . . . . 28<br />
Part No. Page Part No. Page Part No. Page<br />
See page 4 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
See page 2 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong>
Index Part Number B0509590 – B3001262<br />
Index<br />
Part Number<br />
412<br />
B0509590 . . . . . . . . . . . . . . . . . . . . . . . . 23, 28<br />
B0509591 . . . . . . . . . . . . . . . . . . . . . . . . . . 380<br />
B0509612 . . . . . . . . . . . . . . . . . . . . . . . . . . . 27<br />
B0509650 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8<br />
B0509652 . . . . . . . . . . . . . . . . . . . . . . . . . . . 10<br />
B0510032 . . . . . . . . . . . . . . . . . . . . . . . . . . . 27<br />
B0510070 . . . . . . . . . . . . . . . . . . . . . . . . . . 386<br />
B0510251 . . . . . . . . . . . . . . . . . . . . . . . . . . 146<br />
B0510364 . . . . . . . . . . . . . . . . . . . . . . . . . . 147<br />
B0510366 . . . . . . . . . . . . . . . . . . . . . . . . . . 385<br />
B0510370 . . . . . . . . . . . . . . . . . . . . . . . . . . . 22<br />
B0510397 . . . . . . . . . . . . . . . . . . . . . . . . . . . 11<br />
B0510398 . . . . . . . . . . . . . . . . . . . . . . . . . . . 11<br />
B0510403 . . . . . . . . . . . . . . . . . . . . . . . . . . 146<br />
B0510404 . . . . . . . . . . . . . . . . . . . . . . . . . . . 11<br />
B0510412 . . . . . . . . . . . . . . . . . . . . . . . . . . 385<br />
B0510417 . . . . . . . . . . . . . . . . . . . . . . . . . . . 11<br />
B0510487 . . . . . . . . . . . . . . . . . . . . . . . . . . . 22<br />
B0510581 . . . . . . . . . . . . . . . . . . . . . . . . . . 400<br />
B0510984 . . . . . . . . . . . . . . . . . . . . . . . . . . 145<br />
B0511502 . . . . . . . . . . . . . . . . . . . . . . . . . . . 51<br />
B0511503 . . . . . . . . . . . . . . . . . . . . . . . . . . . 51<br />
B0511504 . . . . . . . . . . . . . . . . . . . . . . . . . . . 51<br />
B0511505 . . . . . . . . . . . . . . . . . . . . . . . . . . . 51<br />
B0511506 . . . . . . . . . . . . . . . . . . . . . . . . . . . 52<br />
B0511507 . . . . . . . . . . . . . . . . . . . . . . . . . . . 52<br />
B0511511 . . . . . . . . . . . . . . . . . . . . . . . . . . . 52<br />
B0511512 . . . . . . . . . . . . . . . . . . . . . . . . . . . 52<br />
B0511513 . . . . . . . . . . . . . . . . . . . . . . . . . . . 51<br />
B0511514 . . . . . . . . . . . . . . . . . . . . . . . . . . . 51<br />
B0511515 . . . . . . . . . . . . . . . . . . . . . . . . . . . 51<br />
B0511516 . . . . . . . . . . . . . . . . . . . . . . . . . . . 51<br />
B0511517 . . . . . . . . . . . . . . . . . . . . . . . . . . . 51<br />
B0511518 . . . . . . . . . . . . . . . . . . . . . . . . . . . 51<br />
B0511519 . . . . . . . . . . . . . . . . . . . . . . . . . . . 51<br />
B0511522 . . . . . . . . . . . . . . . . . . . . . . . . . . . 51<br />
B0511523 . . . . . . . . . . . . . . . . . . . . . . . . . . . 51<br />
B0511524 . . . . . . . . . . . . . . . . . . . . . . . . . . . 51<br />
B0511525 . . . . . . . . . . . . . . . . . . . . . . . . . . . 51<br />
B0511526 . . . . . . . . . . . . . . . . . . . . . . . . . . . 51<br />
B0511527 . . . . . . . . . . . . . . . . . . . . . . . . . . . 51<br />
B0511528 . . . . . . . . . . . . . . . . . . . . . . . . . . . 52<br />
B0511529 . . . . . . . . . . . . . . . . . . . . . . . . . . . 52<br />
B0511530 . . . . . . . . . . . . . . . . . . . . . . . . . . . 52<br />
B0511532 . . . . . . . . . . . . . . . . . . . . . . . . . . . 54<br />
B0511533 . . . . . . . . . . . . . . . . . . . . . . . . . . . 54<br />
B0511534 . . . . . . . . . . . . . . . . . . . . . . . . . . . 54<br />
B0511535 . . . . . . . . . . . . . . . . . . . . . . . . . . . 54<br />
B0511537 . . . . . . . . . . . . . . . . . . . . . . . . . . . 55<br />
B0511538 . . . . . . . . . . . . . . . . . . . . . . . . . . . 54<br />
B0511539 . . . . . . . . . . . . . . . . . . . . . . . . . . . 54<br />
B0511540 . . . . . . . . . . . . . . . . . . . . . . . . . . . 55<br />
B0511541 . . . . . . . . . . . . . . . . . . . . . . . . 53, 55<br />
B0511546 . . . . . . . . . . . . . . . . . . . . . . . . . . . 55<br />
B0511601 . . . . . . . . . . . . . . . . . . . . . . . . . . . 51<br />
B0511602 . . . . . . . . . . . . . . . . . . . . . . . . . . . 51<br />
B0511603 . . . . . . . . . . . . . . . . . . . . . . . . . . . 51<br />
B0511674 . . . . . . . . . . . . . . . . . . . . . . . . . . . 54<br />
B0511675 . . . . . . . . . . . . . . . . . . . . . . . . . . . 54<br />
B0511676 . . . . . . . . . . . . . . . . . . . . . . . . . . . 54<br />
B0511677 . . . . . . . . . . . . . . . . . . . . . . . . 53, 55<br />
B0511678 . . . . . . . . . . . . . . . . . . . . . . . . . . . 54<br />
B0511679 . . . . . . . . . . . . . . . . . . . . . . . . . . . 55<br />
B0511778 . . . . . . . . . . . . . . . . . . . . . . . . . . . 37<br />
B0511779 . . . . . . . . . . . . . . . . . . . . . . . . . . . 37<br />
B0511806 . . . . . . . . . . . . . . . . . . . . . . . . . . . 37<br />
B0631001 . . . . . . . . . . . . . . . . . . . . . . . . . . 392<br />
B0631002 . . . . . . . . . . . . . . . . . . . . . . . . . . 392<br />
B0631003 . . . . . . . . . . . . . . . . . . . . . . . . . . 392<br />
B0631004 . . . . . . . . . . . . . . . . . . . . . . . . . . 392<br />
B0631005 . . . . . . . . . . . . . . . . . . . . . . . . . . 392<br />
B0631006 . . . . . . . . . . . . . . . . . . . . . . . . . . 392<br />
B0631007 . . . . . . . . . . . . . . . . . . . . . . . . . . 392<br />
B0631008 . . . . . . . . . . . . . . . . . . . . . . . . . . 392<br />
B0631009 . . . . . . . . . . . . . . . . . . . . . . . . . . 392<br />
B0631010 . . . . . . . . . . . . . . . . . . . . . . . . . . 392<br />
B0631011 . . . . . . . . . . . . . . . . . . . . . . . . . . 392<br />
B0631012 . . . . . . . . . . . . . . . . . . . . . . . . . . 392<br />
B0631013 . . . . . . . . . . . . . . . . . . . . . . 249, 392<br />
B0631014 . . . . . . . . . . . . . . . . . . . . . . 249, 392<br />
B0631015 . . . . . . . . . . . . . . . . . . . . . . 249, 392<br />
B0631016 . . . . . . . . . . . . . . . . . . . . . . 249, 392<br />
B0631017 . . . . . . . . . . . . . . . . . . . . . . 249, 392<br />
B0631018 . . . . . . . . . . . . . . . . . . . . . . 249, 392<br />
B0631019 . . . . . . . . . . . . . . . . . . . . . . . . . . 392<br />
B0631020 . . . . . . . . . . . . . . . . . . . . . . . . . . 392<br />
B0631021 . . . . . . . . . . . . . . . . . . . . . . . . . . 392<br />
B0631023 . . . . . . . . . . . . . . . . . . . . . . . . . . 392<br />
B0631025 . . . . . . . . . . . . . . . . . . . . . . . . . . 392<br />
B0631026 . . . . . . . . . . . . . . . . . . . . . . . . . . 392<br />
B0631027 . . . . . . . . . . . . . . . . . . . . . . . . . . 392<br />
B0631028 . . . . . . . . . . . . . . . . . . . . . . . . . . 392<br />
B0631029 . . . . . . . . . . . . . . . . . . . . . . . . . . 392<br />
B0631030 . . . . . . . . . . . . . . . . . . . . . . . . . . 392<br />
B0631031 . . . . . . . . . . . . . . . . . . . . . . 249, 392<br />
B0631032 . . . . . . . . . . . . . . . . . . . . . . 249, 392<br />
B0631033 . . . . . . . . . . . . . . . . . . . . . . 249, 392<br />
B0631034 . . . . . . . . . . . . . . . . . . . . . . 249, 392<br />
B0631035 . . . . . . . . . . . . . . . . . . . . . . 249, 392<br />
B0631036 . . . . . . . . . . . . . . . . . . . . . . 249, 392<br />
B0631039 . . . . . . . . . . . . . . . . . . . . . . . . . . 393<br />
B0631042 . . . . . . . . . . . . . . . . . . . . . . . . . . 393<br />
B0631045 . . . . . . . . . . . . . . . . . . . . . . 249, 393<br />
B0631046 . . . . . . . . . . . . . . . . . . . . . . . . . . 393<br />
B0631047 . . . . . . . . . . . . . . . . . . . . . . . . . . 393<br />
B0631048 . . . . . . . . . . . . . . . . . . . . . . . . . . 393<br />
B0631049 . . . . . . . . . . . . . . . . . . . . . . . . . . 393<br />
B0631050 . . . . . . . . . . . . . . . . . . . . . . . . . . 393<br />
B0631051 . . . . . . . . . . . . . . . . . . . . . . 249, 393<br />
B0631057 . . . . . . . . . . . . . . . . . . . . . . . . . . 394<br />
B0631060 . . . . . . . . . . . . . . . . . . . . . . 249, 394<br />
B0631061 . . . . . . . . . . . . . . . . . . . . . . . . . . 394<br />
B0631064 . . . . . . . . . . . . . . . . . . . . . . . . . . 394<br />
B0631065 . . . . . . . . . . . . . . . . . . . . . . 249, 394<br />
B0631066 . . . . . . . . . . . . . . . . . . . . . . 249, 394<br />
B0631070 . . . . . . . . . . . . . . . . . . . . . . . . . . 393<br />
B0631071 . . . . . . . . . . . . . . . . . . . . . . . . . . 393<br />
B0631076 . . . . . . . . . . . . . . . . . . . . . . . . . . 393<br />
B0631077 . . . . . . . . . . . . . . . . . . . . . . . . . . 393<br />
B0631078 . . . . . . . . . . . . . . . . . . . . . . 249, 393<br />
B0631079 . . . . . . . . . . . . . . . . . . . . . . . . . . 394<br />
B0631080 . . . . . . . . . . . . . . . . . . . . . . . . . . 394<br />
B0631081 . . . . . . . . . . . . . . . . . . . . . . . . . . 394<br />
B0631082 . . . . . . . . . . . . . . . . . . . . . . . . . . 394<br />
B0631083 . . . . . . . . . . . . . . . . . . . . . . . . . . 394<br />
B0631084 . . . . . . . . . . . . . . . . . . . . . . . . . . 391<br />
B0631085 . . . . . . . . . . . . . . . . . . . . . . . . . . 391<br />
B0631087 . . . . . . . . . . . . . . . . . . . . . . 383, 391<br />
B0631088 . . . . . . . . . . . . . . . . . . . . . . 383, 391<br />
B0631089 . . . . . . . . . . . . . . . . . . . . . . . . . . 391<br />
B0631090 . . . . . . . . . . . . . . . . . . . . . . . . . . 391<br />
B0631091 . . . . . . . . . . . . . . . . . . . . . . . . . . 391<br />
B0631092 . . . . . . . . . . . . . . . . . . . . . . . . . . 391<br />
B0631093 . . . . . . . . . . . . . . . . . . . . . . . . . . 391<br />
B0631094 . . . . . . . . . . . . . . . . . . . . . . . . . . 391<br />
B0631095 . . . . . . . . . . . . . . . . . . . . . . . . . . 391<br />
B0631096 . . . . . . . . . . . . . . . . . . . . . . . . . . 391<br />
B0631097 . . . . . . . . . . . . . . . . . . . . . . . . . . 391<br />
B0631098 . . . . . . . . . . . . . . . . . . . . . . . . . . 391<br />
B0631099 . . . . . . . . . . . . . . . . . . . . . . 249, 391<br />
B0631100 . . . . . . . . . . . . . . . . . . . . . . 249, 391<br />
B0631101 . . . . . . . . . . . . . . . . . . . . . . 249, 391<br />
B0631102 . . . . . . . . . . . . . . . . . . . . . . 249, 391<br />
B0631128 . . . . . . . . . . . . . . . . . . . . . . 249, 391<br />
B0631129 . . . . . . . . . . . . . . . . . . . . . . 249, 391<br />
B0631130 . . . . . . . . . . . . . . . . . . . . . . . . . . 391<br />
B0631131 . . . . . . . . . . . . . . . . . . . . . . . . . . 391<br />
B0631134 . . . . . . . . . . . . . . . . . . . . . . . . . . 392<br />
B0631144 . . . . . . . . . . . . . . . . . . . . . . . . . . 391<br />
B0631145 . . . . . . . . . . . . . . . . . . . . . . 249, 391<br />
B0631146 . . . . . . . . . . . . . . . . . . . . . . . . . . 391<br />
B0631147 . . . . . . . . . . . . . . . . . . . . . . . . . . 391<br />
B0631148 . . . . . . . . . . . . . . . . . . . . . . . . . . 391<br />
B0631149 . . . . . . . . . . . . . . . . . . . . . . 249, 391<br />
B0631150 . . . . . . . . . . . . . . . . . . . . . . . . . . 391<br />
B0631151 . . . . . . . . . . . . . . . . . . . . . . . . . . 391<br />
B0631152 . . . . . . . . . . . . . . . . . . . . . . . . . . 391<br />
B0810144 . . . . . . . . . . . . . . . . . . . . . . . . . . 216<br />
B0810377 . . . . . . . . . . . . . . . . . . . . . . . . . . 219<br />
B0851900 . . . . . . . . . . . . . . . . . . . . . . . . . . . 35<br />
B2000159 . . . . . . . . . . . . . . . . . . . . . . . . . . 385<br />
B2000160 . . . . . . . . . . . . . . . . . . . . . . . . . . 385<br />
B2000186 . . . . . . . . . . . . . . . . . . . . . . . . . . 387<br />
B2000199 . . . . . . . . . . . . . . . . . . . . . . . . . . 387<br />
B2000201 . . . . . . . . . . . . . . . . . . . . . . . . . . 389<br />
B2000310 . . . . . . . . . . . . . . . . . . . . . . . . . . 387<br />
B2100154 . . . . . . . . . . . . . . . . . . . . . . . . . . 400<br />
B2190036 . . . . . . . . . . . . . . . . . . . . . . . . . . 382<br />
B2190037 . . . . . . . . . . . . . . . . . . . . . . . . . . 383<br />
B2190038 . . . . . . . . . . . . . . . . . . . . . . . . . . 383<br />
B2205021 . . . . . . . . . . . . . . . . . . . . . . . . . . 382<br />
B2205022 . . . . . . . . . . . . . . . . . . . . . . . . . . 382<br />
B2205104 . . . . . . . . . . . . . . . . . . . . . . . . . . 388<br />
B2205302 . . . . . . . . . . . . . . . . . . . . . . . . . . 380<br />
B2205401 . . . . . . . . . . . . . . . . . . . . . . . . . . 388<br />
B2205411 . . . . . . . . . . . . . . . . . . . . . . . . . . 389<br />
B2205420 . . . . . . . . . . . . . . . . . . . . . . . . . . 388<br />
B2500080 . . . . . . . . . . . . . . . . . . . . . . . . . . 387<br />
B2500081 . . . . . . . . . . . . . . . . . . . . . . . . . . 389<br />
B2500082 . . . . . . . . . . . . . . . . . . . . . . . . . . 389<br />
B2500083 . . . . . . . . . . . . . . . . . . . . . . . . . . 389<br />
B2500099 . . . . . . . . . . . . . . . . . . . . . . . . . . 395<br />
B2500100 . . . . . . . . . . . . . . . . . . . . . . . . . . 395<br />
B2500103 . . . . . . . . . . . . . . . . . . . . . . . . . . 383<br />
B2500127 . . . . . . . . . . . . . . . . . . . . . . . . . . 391<br />
B2500129 . . . . . . . . . . . . . . . . . . . . . . . . . . 391<br />
B3000001 . . . . . . . . . . . . . . . . . . . . . . . . . . . 25<br />
B3000019 . . . . . . . . . . . . . . . . . . . . . . . . . . . 10<br />
B3000055 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9<br />
B3000111 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8<br />
B3000132 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8<br />
B3000133 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8<br />
B3000135 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8<br />
B3000152 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9<br />
B3000157 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9<br />
B3000158 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9<br />
B3000159 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9<br />
B3000160 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9<br />
B3000161 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9<br />
B3000166 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8<br />
B3000240 . . . . . . . . . . . . . . . . . . . . . . . . . . . 23<br />
B3000243 . . . . . . . . . . . . . . . . . . . . . . . . . . . 22<br />
B3000251 . . . . . . . . . . . . . . . . . . . . . . . . . . . 23<br />
B3000274 . . . . . . . . . . . . . . . . . . . . . . . . . . . 22<br />
B3000277 . . . . . . . . . . . . . . . . . . . . . . . . . . . 22<br />
B3000342 . . . . . . . . . . . . . . . . . . . . . . . . . . . 32<br />
B3000350 . . . . . . . . . . . . . . . . . . . . . . . . 22, 49<br />
B3000641 . . . . . . . . . . . . . . . . . . . . . . . . . . . 34<br />
B3000653 . . . . . . . . . . . . . . . . . . . . . . . . . . . 34<br />
B3000655 . . . . . . . . . . . . . . . . . . . . . . . . . . . 34<br />
B3000656 . . . . . . . . . . . . . . . . . . . . . . . . . . . 45<br />
B3001123 . . . . . . . . . . . . . . . . . . . . . . . . . . . 33<br />
B3001124 . . . . . . . . . . . . . . . . . . . . . . . . . . . 33<br />
B3001254 . . . . . . . . . . . . . . . . . . . . . . . . . . . 32<br />
B3001256 . . . . . . . . . . . . . . . . . . . . . . . . . . . 31<br />
B3001262 . . . . . . . . . . . . . . . . . . . . . . . . . . . 32<br />
Part No. Page Part No. Page Part No. Page
B3001264 – L1200406 Part Number Index<br />
Index<br />
Part Number<br />
413<br />
B3001264 . . . . . . . . . . . . . . . . . . . . . . . . . . . 32<br />
B3001330 . . . . . . . . . . . . . . . . . . . . . . . . . . . 11<br />
B3001333 . . . . . . . . . . . . . . . . . . . . . . . . 10, 12<br />
B3001334 . . . . . . . . . . . . . . . . . . . . . . . . 10, 12<br />
B3001335 . . . . . . . . . . . . . . . . . . . . . . . . . . . 10<br />
B3001465 . . . . . . . . . . . . . . . . . . . . . . . . . . . 11<br />
B3001505 . . . . . . . . . . . . . . . . . . . . . . . . . . . 11<br />
B3001506 . . . . . . . . . . . . . . . . . . . . . . . . . . . 11<br />
B3001507 . . . . . . . . . . . . . . . . . . . . . . . . . . . 11<br />
B3001566 . . . . . . . . . . . . . . . . . . . . . . . . . . . 11<br />
B3001567 . . . . . . . . . . . . . . . . . . . . . . . . . . . 11<br />
B3001647 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8<br />
B3001769 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9<br />
B3001770 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9<br />
B3001771 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9<br />
B3001772 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9<br />
B3002006 . . . . . . . . . . . . . . . . . . . . . . . . . . . 11<br />
B3002007 . . . . . . . . . . . . . . . . . . . . . . . . . . . 11<br />
B3002046 . . . . . . . . . . . . . . . . . . . . . . . . . . . 11<br />
B3002072 . . . . . . . . . . . . . . . . . . . . . . . . . . . 10<br />
B3002076 . . . . . . . . . . . . . . . . . . . . . . . . . . . 10<br />
B3002091 . . . . . . . . . . . . . . . . . . . . . . . . . . . 10<br />
B3002094 . . . . . . . . . . . . . . . . . . . . . . . . . . . 10<br />
B3002097 . . . . . . . . . . . . . . . . . . . . . . . . . . . 10<br />
B3002102 . . . . . . . . . . . . . . . . . . . . . . . . . . . 34<br />
B3002103 . . . . . . . . . . . . . . . . . . . . . . . . . . . 34<br />
B3120405 . . . . . . . . . . . . . . . . . . . . . . . . . . . 34<br />
B3121301 . . . . . . . . . . . . . . . . . . . . . . . . . . . 31<br />
B3130086 . . . . . . . . . . . . . . . . . . . . . . . . . . . 31<br />
B3140123 . . . . . . . . . . . . . . . . . . . . . . . . . . . 10<br />
B3140210 . . . . . . . . . . . . . . . . . . . . . . . . . . . 10<br />
B3140211 . . . . . . . . . . . . . . . . . . . . . . . . . . . 10<br />
B3140226 . . . . . . . . . . . . . . . . . . . . . . . . . . . 10<br />
B3140227 . . . . . . . . . . . . . . . . . . . . . . . . . . . 10<br />
B3140236 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8<br />
B3140244 . . . . . . . . . . . . . . . . . . . . . . . . . . . 10<br />
B3140255 . . . . . . . . . . . . . . . . . . . . . . . . . . . 27<br />
B3140361 . . . . . . . . . . . . . . . . . . . . . . . . . . . 34<br />
B3140362 . . . . . . . . . . . . . . . . . . . . . . . . . . . 34<br />
B3140380 . . . . . . . . . . . . . . . . . . . . . . . . 53, 55<br />
B3140381 . . . . . . . . . . . . . . . . . . . . . . . . . . . 55<br />
B3140382 . . . . . . . . . . . . . . . . . . . . . . . . . . . 54<br />
B3140383 . . . . . . . . . . . . . . . . . . . . . . . . . . . 54<br />
B3140386 . . . . . . . . . . . . . . . . . . . . . . . . . . . 55<br />
B3140387 . . . . . . . . . . . . . . . . . . . . . . . . . . . 55<br />
B3140617 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8<br />
B3140618 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8<br />
B3140621 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8<br />
B3140622 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8<br />
B3140647 . . . . . . . . . . . . . . . . . . . . . . . . 8, 188<br />
B3140715 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8<br />
B3140721 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8<br />
B3140730 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8<br />
B3140760 . . . . . . . . . . . . . . . . . . . . . . . . . . . 49<br />
B3140770 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8<br />
B3141052 . . . . . . . . . . . . . . . . . . . . . . . . . . . 10<br />
B3141064 . . . . . . . . . . . . . . . . . . . . . . . . 33, 67<br />
B3150169 . . . . . . . . . . . . . . . . . . . . . . . . . . . 45<br />
B4000011 . . . . . . . . . . . . . . . . . . . . . . . . . . 147<br />
B4000012 . . . . . . . . . . . . . . . . . . . . . . . . . . 146<br />
B4000022 . . . . . . . . . . . . . . . . . . . . . . . . . . 148<br />
B4000025 . . . . . . . . . . . . . . . . . . . . . . . . . . 148<br />
B4000028 . . . . . . . . . . . . . . . . . . . . . . . . . . 148<br />
B4000033 . . . . . . . . . . . . . . . . . . . . . . . . . . 146<br />
B4000046 . . . . . . . . . . . . . . . . . . . . . . . . . . 144<br />
B4000057 . . . . . . . . . . . . . . . . . . . . . . . . . . 143<br />
C0550303 . . . . . . . . . . . . . . . . . . . . . . . . . . 388<br />
C0550500 . . . . . . . . . . . . . . . . . . . . . . . 45, 397<br />
C0550505 . . . . . . . . . . . . . . . . . . . . . . . . . . 397<br />
C0991141 . . . . . . . . . . . . . . . . . . . . . . . . . . 375<br />
C3220112 . . . . . . . . . . . . . . . . . . . . . . . . . . 375<br />
C3221027 . . . . . . . . . . . . . . . . . . . . . . . . . . 375<br />
C6880054 . . . . . . . . . . . . . . . . . . . . . . . . . . 397<br />
C6880055 . . . . . . . . . . . . . . . . . . . . . . . . . . 397<br />
C6950209 . . . . . . . . . . . . . . . . . . . . . . . . . . 381<br />
C6951019 . . . . . . . . . . . . . . . . . . . . . . . . . . 381<br />
CP183700 . . . . . . . . . . . . . . . . . . . . . . . . . . 387<br />
E5711269 . . . . . . . . . . . . . . . . . . . . . . . . . . 138<br />
E5711272 . . . . . . . . . . . . . . . . . . . . . . . . . . 137<br />
E6070836 . . . . . . . . . . . . . . . . . . . . . . . . . . 137<br />
E6400206 . . . . . . . . . . . . . . . . . . . . . . . . . . 137<br />
E6400207 . . . . . . . . . . . . . . . . . . . . . . . . . . 137<br />
E6400208 . . . . . . . . . . . . . . . . . . . . . . . . . . 137<br />
E6400209 . . . . . . . . . . . . . . . . . . . . . . . . . . 137<br />
E6400211 . . . . . . . . . . . . . . . . . . . . . . . . . . 137<br />
E6400223 . . . . . . . . . . . . . . . . . . . . . . . . . . 137<br />
E6400242 . . . . . . . . . . . . . . . . . . . . . . . . . . 137<br />
E6400247 . . . . . . . . . . . . . . . . . . . . . . . . . . 137<br />
E6400251 . . . . . . . . . . . . . . . . . . . . . . . . . . 137<br />
E6400265 . . . . . . . . . . . . . . . . . . . . . . . . . . 137<br />
E6401017 . . . . . . . . . . . . . . . . . . . . . . . . . . 137<br />
E6401208 . . . . . . . . . . . . . . . . . . . . . . . . . . 137<br />
E6401213 . . . . . . . . . . . . . . . . . . . . . . . . . . 137<br />
E6401214 . . . . . . . . . . . . . . . . . . . . . . . . . . 137<br />
E6401217 . . . . . . . . . . . . . . . . . . . . . . . . . . 137<br />
E6401219 . . . . . . . . . . . . . . . . . . . . . . . . . . 137<br />
E6401220 . . . . . . . . . . . . . . . . . . . . . . . . . . 137<br />
E6401308 . . . . . . . . . . . . . . . . . . . . . . . . . . 138<br />
E6401309 . . . . . . . . . . . . . . . . . . . . . . . . . . 138<br />
E6401384 . . . . . . . . . . . . . . . . . . . . . . . . . . 137<br />
E6420003 . . . . . . . . . . . . . . . . . . . . . . . . . . 138<br />
E6420007 . . . . . . . . . . . . . . . . . . . . . . . . . . 138<br />
E6420021 . . . . . . . . . . . . . . . . . . . . . . . . . . 137<br />
ED020005 . . . . . . . . . . . . . . . . . . . . . . . . . . 323<br />
ED020008 . . . . . . . . . . . . . . . . . . . . . . . . . . 323<br />
ED020015 . . . . . . . . . . . . . . . . . . . . . . . . . . 327<br />
ED020016 . . . . . . . . . . . . . . . . . . . . . . . . . . 327<br />
ED020017 . . . . . . . . . . . . . . . . . . . . . . . . . . 327<br />
L1003006 . . . . . . . . . . . . . . . . . . . . . . 183-184<br />
L1003008 . . . . . . . . . . . . . . . . . . . . . . . . . . 184<br />
L1003012 . . . . . . . . . . . . . . . . . . . . . . . . . . 243<br />
L1003015 . . . . . . . . . . . . . . . . . . . . . . . . . . 181<br />
L1003018 . . . . . . . . . . . . . . . . . . . . . . . . . . 243<br />
L1003020 . . . . . . . . . . . . . . . . . . . . . . 243-244<br />
L1003021 . . . . . . . . . . . . . . . . . . . . . . 243-244<br />
L1003030 . . . . . . . . . . . . . . . . . . . . . . . . . . 183<br />
L1060351 . . . . . . . . . . . . . . . . . . . . . . 258-259<br />
L1100974 . . . . . . . . . . . . . . . . . . . . . . . . . . 264<br />
L1100980 . . . . . . . . . . . . . . . . . . . . . . . . . . 263<br />
L1100981 . . . . . . . . . . . . . . . . . . . . . . . . . . 263<br />
L1108548 . . . . . . . . . . . . . . . . . . . . . . . . . . 262<br />
L1108755 . . . . . . . . . . . . . . . . . . . . . . . . . . 261<br />
L1108757 . . . . . . . . . . . . . . . . . . . . . . . . . . 261<br />
L1108758 . . . . . . . . . . . . . . . . . . . . . . . . . . 261<br />
L1108759 . . . . . . . . . . . . . . . . . . . . . . . . . . 261<br />
L1108760 . . . . . . . . . . . . . . . . . . . . . . . . . . 261<br />
L1108772 . . . . . . . . . . . . . . . . . . . . . . . . . . 261<br />
L1108818 . . . . . . . . . . . . . . . . . . . . . . . . . . 262<br />
L1108822 . . . . . . . . . . . . . . . . . . . . . . . . . . 261<br />
L1108823 . . . . . . . . . . . . . . . . . . . . . . . . . . 261<br />
L1108824 . . . . . . . . . . . . . . . . . . . . . . . . . . 261<br />
L1160333 . . . . . . . . . . . . . . . . . . . . . . . . . . 240<br />
L1160550 . . . . . . . . . . . . . . . . . . . . . . . . . . 252<br />
L1160581 . . . . . . . . . . . . . . . . . . . . . . . . . . 252<br />
L1160582 . . . . . . . . . . . . . . . . . . . . . . . . . . 252<br />
L1160583 . . . . . . . . . . . . . . . . . . . . . . . . . . 252<br />
L1160585 . . . . . . . . . . . . . . . . . . . . . . . . . . 252<br />
L1180480 . . . . . . . . . . . . . . . . . . . . . . . . . . 240<br />
L1180486 . . . . . . . . . . . . . . . . . . . . . . . . . . 240<br />
L1180501 . . . . . . . . . . . . . . . . . . . . . . . . . . 256<br />
L1180502 . . . . . . . . . . . . . . . . . . . . . . . . . . 256<br />
L1180503 . . . . . . . . . . . . . . . . . . . . . . . . . . 256<br />
L1181056 . . . . . . . . . . . . . . . . . . . . . . . . . . 241<br />
L1181257 . . . . . . . . . . . . . . . . . . . . . . . . . . 256<br />
L1181301 . . . . . . . . . . . . . . . . . . . . . . . . . . 249<br />
L1181302 . . . . . . . . . . . . . . . . . . . . . . . . . . 249<br />
L1181303 . . . . . . . . . . . . . . . . . . . . . . . . . . 249<br />
L1181304 . . . . . . . . . . . . . . . . . . . . . . . . . . 249<br />
L1181314 . . . . . . . . . . . . . . . . . . . . . . . . . . 260<br />
L1181316 . . . . . . . . . . . . . . . . . . . . . . . . . . 260<br />
L1181318 . . . . . . . . . . . . . . . . . . . . . . . . . . 256<br />
L1181319 . . . . . . . . . . . . . . . . . . . . . . . . . . 256<br />
L1181322 . . . . . . . . . . . . . . . . . . . . . . . . . . 241<br />
L1185153 . . . . . . . . . . . . . . . . . . . . . . . . . . 256<br />
L1185305 . . . . . . . . . . . . . . . . . . . . . . . . . . 256<br />
L1191014 . . . . . . . . . . . . . . . . . . . . . . . . . . 242<br />
L1191015 . . . . . . . . . . . . . . . . . . . . . . . . . . 243<br />
L1191018 . . . . . . . . . . . . . . . . . . . . . . . . . . 242<br />
L1191021 . . . . . . . . . . . . . . . . . . . . . . . . . . 242<br />
L1191031 . . . . . . . . . . . . . . . . . . . . . . . . . . 243<br />
L1191079 . . . . . . . . . . . . . . . . . . . . . . . . . . 242<br />
L1191080 . . . . . . . . . . . . . . . . . . . . . . . . . . 242<br />
L1191081 . . . . . . . . . . . . . . . . . . . . . . . . . . 242<br />
L1191082 . . . . . . . . . . . . . . . . . . . . . . . . . . 242<br />
L1191099 . . . . . . . . . . . . . . . . . . . . . . . . . . 242<br />
L1191113 . . . . . . . . . . . . . . . . . . . . . . . . . . 242<br />
L1191114 . . . . . . . . . . . . . . . . . . . . . . . . . . 243<br />
L1191202 . . . . . . . . . . . . . . . . . . . . . . . . . . 242<br />
L1191207 . . . . . . . . . . . . . . . . . . . . . . . . . . 242<br />
L1191210 . . . . . . . . . . . . . . . . . . . . . . . . . . 242<br />
L1191211 . . . . . . . . . . . . . . . . . . . . . . . . . . 242<br />
L1195019 . . . . . . . . . . . . . . . . . . . . . . . . . . 242<br />
L1200205 . . . . . . . . . . . . . . . . . . . . . . . . . . 265<br />
L1200214 . . . . . . . . . . . . . . . . . . . . . . . . . . 240<br />
L1200216 . . . . . . . . . . . . . . . . . . . . . . . . . . 240<br />
L1200219 . . . . . . . . . . . . . . . . . . . . . . . . . . 240<br />
L1200220 . . . . . . . . . . . . . . . . . . . . . . . . . . 265<br />
L1200223 . . . . . . . . . . . . . . . . . . . . . . . . . . 265<br />
L1200236 . . . . . . . . . . . . . . . . . . . . . . . . . . 265<br />
L1200237 . . . . . . . . . . . . . . . . . . . . . . . . . . 265<br />
L1200238 . . . . . . . . . . . . . . . . . . . . . . . . . . 265<br />
L1200241 . . . . . . . . . . . . . . . . . . . . . . . . . . 265<br />
L1200253 . . . . . . . . . . . . . . . . . . . . . . . . . . 240<br />
L1200254 . . . . . . . . . . . . . . . . . . . . . . . . . . 265<br />
L1200301 . . . . . . . . . . . . . . . . . . . . . . . . . . 265<br />
L1200302 . . . . . . . . . . . . . . . . . . . . . . . . . . 265<br />
L1200306 . . . . . . . . . . . . . . . . . . . . . . . . . . 244<br />
L1200308 . . . . . . . . . . . . . . . . . . . . . . . . . . 244<br />
L1200309 . . . . . . . . . . . . . . . . . . . . . . . . . . 244<br />
L1200310 . . . . . . . . . . . . . . . . . . . . . . . . . . 244<br />
L1200313 . . . . . . . . . . . . . . . . . . . . . . . . . . 255<br />
L1200314 . . . . . . . . . . . . . . . . . . . . . . . . . . 255<br />
L1200315 . . . . . . . . . . . . . . . . . . . . . . . . . . 255<br />
L1200316 . . . . . . . . . . . . . . . . . . . . . . . . . . 255<br />
L1200321 . . . . . . . . . . . . . . . . . . . . . . . . . . 256<br />
L1200323 . . . . . . . . . . . . . . . . . . . . . . . . . . 255<br />
L1200324 . . . . . . . . . . . . . . . . . . . . . . . . . . 255<br />
L1200325 . . . . . . . . . . . . . . . . . . . . . . . . . . 255<br />
L1200333 . . . . . . . . . . . . . . . . . . . . . . . . . . 255<br />
L1200334 . . . . . . . . . . . . . . . . . . . . . . . . . . 255<br />
L1200335 . . . . . . . . . . . . . . . . . . . . . . . . . . 255<br />
L1200336 . . . . . . . . . . . . . . . . . . . . . . . . . . 255<br />
L1200337 . . . . . . . . . . . . . . . . . . . . . . . . . . 255<br />
L1200338 . . . . . . . . . . . . . . . . . . . . . . . . . . 255<br />
L1200343 . . . . . . . . . . . . . . . . . . . . . . . . . . 255<br />
L1200344 . . . . . . . . . . . . . . . . . . . . . . . . . . 255<br />
L1200345 . . . . . . . . . . . . . . . . . . . . . . . . . . 255<br />
L1200346 . . . . . . . . . . . . . . . . . . . . . . . . . . 255<br />
L1200364 . . . . . . . . . . . . . . . . . . . . . . . . . . 256<br />
L1200365 . . . . . . . . . . . . . . . . . . . . . . . . . . 256<br />
L1200366 . . . . . . . . . . . . . . . . . . . . . . . . . . 256<br />
L1200390 . . . . . . . . . . . . . . . . . . . . . . . . . . 265<br />
L1200392 . . . . . . . . . . . . . . . . . . . . . . . . . . 265<br />
L1200393 . . . . . . . . . . . . . . . . . . . . . . . . . . 256<br />
L1200394 . . . . . . . . . . . . . . . . . . . . . . . . . . 255<br />
L1200406 . . . . . . . . . . . . . . . . . . . . . . . . . . 241<br />
Part No. Page Part No. Page Part No. Page<br />
See page 4 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
See page 2 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong>
Index Part Number L1200551 – LX100846<br />
Index<br />
Part Number<br />
414<br />
L1200551 . . . . . . . . . . . . . . . . . . . . . . . . . . 243<br />
L1200552 . . . . . . . . . . . . . . . . . . . . . . . . . . 243<br />
L1200553 . . . . . . . . . . . . . . . . . . . . . . . . . . 243<br />
L1200555 . . . . . . . . . . . . . . . . . . . . . . . . . . 242<br />
L1200556 . . . . . . . . . . . . . . . . . . . . . . . . . . 243<br />
L1200557 . . . . . . . . . . . . . . . . . . . . . . . . . . 243<br />
L1200558 . . . . . . . . . . . . . . . . . . . . . . . . . . 242<br />
L1200559 . . . . . . . . . . . . . . . . . . . . . . . . . . 243<br />
L1200560 . . . . . . . . . . . . . . . . . . . . . . . . . . 243<br />
L1200574 . . . . . . . . . . . . . . . . . . . . . . . . . . 243<br />
L1200587 . . . . . . . . . . . . . . . . . . . . . . . . . . 243<br />
L1200588 . . . . . . . . . . . . . . . . . . . . . . . . . . 243<br />
L1200589 . . . . . . . . . . . . . . . . . . . . . . . . . . 243<br />
L1201231 . . . . . . . . . . . . . . . . . . . . . . . . . . 244<br />
L1201654 . . . . . . . . . . . . . . . . . . . . . . . . . . 255<br />
L1201655 . . . . . . . . . . . . . . . . . . . . . . . . . . 255<br />
L1201865 . . . . . . . . . . . . . . . . . . . . . . . . . . 255<br />
L1201904 . . . . . . . . . . . . . . . . . . . . . . . . . . 244<br />
L1201905 . . . . . . . . . . . . . . . . . . . . . . . . . . 244<br />
L1201989 . . . . . . . . . . . . . . . . . . . . . . . . . . 244<br />
L1202006 . . . . . . . . . . . . . . . . . . . . . . . . . . 244<br />
L1202035 . . . . . . . . . . . . . . . . . . . . . . . . . . 244<br />
L1202036 . . . . . . . . . . . . . . . . . . . . . . . . . . 244<br />
L1202037 . . . . . . . . . . . . . . . . . . . . . . . . . . 244<br />
L1202057 . . . . . . . . . . . . . . . . . . . . . . . . . . 241<br />
L1202715 . . . . . . . . . . . . . . . . . . . . . . . . . . 244<br />
L1202716 . . . . . . . . . . . . . . . . . . . . . . . . . . 244<br />
L1240053 . . . . . . . . . . . . . . . . . . . . . . . . . . 256<br />
L1240055 . . . . . . . . . . . . . . . . . . . . . . . . . . 249<br />
L1240056 . . . . . . . . . . . . . . . . . . . . . . . . . . 249<br />
L1240057 . . . . . . . . . . . . . . . . . . . . . . . . . . 249<br />
L1240062 . . . . . . . . . . . . . . . . . . . . . . . . . . 260<br />
L1240097 . . . . . . . . . . . . . . . . . . . . . . . . . . 240<br />
L1240098 . . . . . . . . . . . . . . . . . . . . . . . . . . 241<br />
L1240204 . . . . . . . . . . . . . . . . . . . . . . . . . . 265<br />
L1241555 . . . . . . . . . . . . . . . . . . . . . . . . . . 245<br />
L1241556 . . . . . . . . . . . . . . . . . . . . . . . . . . 245<br />
L1241557 . . . . . . . . . . . . . . . . . . . . . . . . . . 245<br />
L1241558 . . . . . . . . . . . . . . . . . . . . . . . . . . 245<br />
L1241559 . . . . . . . . . . . . . . . . . . . . . . . . . . 245<br />
L1241571 . . . . . . . . . . . . . . . . . . . . . . . . . . 245<br />
L1241572 . . . . . . . . . . . . . . . . . . . . . . . . . . 245<br />
L1241573 . . . . . . . . . . . . . . . . . . . . . . . . . . 245<br />
L1241574 . . . . . . . . . . . . . . . . . . . . . . . . . . 245<br />
L1241575 . . . . . . . . . . . . . . . . . . . . . . . . . . 245<br />
L1245024 . . . . . . . . . . . . . . . . . . . . . . . . . . 245<br />
L1245221 . . . . . . . . . . . . . . . . . . . . . . . . . . 260<br />
L1270301 . . . . . . . . . . . . . . . . . . . . . . . . . . 251<br />
L1270402 . . . . . . . . . . . . . . . . . . . . . . . . . . 251<br />
L1270404 . . . . . . . . . . . . . . . . . . . . . . . . . . 251<br />
L1270408 . . . . . . . . . . . . . . . . . . . . . . . . . . 251<br />
L1270409 . . . . . . . . . . . . . . . . . . . . . . . . . . 251<br />
L1270410 . . . . . . . . . . . . . . . . . . . . . . . . . . 251<br />
L1270421 . . . . . . . . . . . . . . . . . . . . . . . . . . 251<br />
L1270503 . . . . . . . . . . . . . . . . . . . . . . . . . . 258<br />
L1270504 . . . . . . . . . . . . . . . . . . . . . . . . . . 258<br />
L1270512 . . . . . . . . . . . . . . . . . . . . . . 248, 251<br />
L1270664 . . . . . . . . . . . . . . . . . . . . . . . . . . 251<br />
L1270665 . . . . . . . . . . . . . . . . . . . . . . . . . . 248<br />
L1270666 . . . . . . . . . . . . . . . . . . . . . . . . . . 251<br />
L1270741 . . . . . . . . . . . . . . . . . . . . . . . . . . 251<br />
L1270742 . . . . . . . . . . . . . . . . . . . . . . . . . . 251<br />
L1270744 . . . . . . . . . . . . . . . . . . . . . . . . . . 251<br />
L1270747 . . . . . . . . . . . . . . . . . . . . . . . . . . 251<br />
L1270748 . . . . . . . . . . . . . . . . . . . . . . . . . . 251<br />
L1270749 . . . . . . . . . . . . . . . . . . . . . . . . . . 251<br />
L1270751 . . . . . . . . . . . . . . . . . . . . . . . . . . 251<br />
L1270752 . . . . . . . . . . . . . . . . . . . . . . . . . . 251<br />
L1270754 . . . . . . . . . . . . . . . . . . . . . . . . . . 251<br />
L1270757 . . . . . . . . . . . . . . . . . . . . . . . . . . 251<br />
L1270758 . . . . . . . . . . . . . . . . . . . . . . . . . . 251<br />
L1270759 . . . . . . . . . . . . . . . . . . . . . . . . . . 251<br />
L1270761 . . . . . . . . . . . . . . . . . . . . . . . . . . 251<br />
L1270762 . . . . . . . . . . . . . . . . . . . . . . . . . . 251<br />
L1270764 . . . . . . . . . . . . . . . . . . . . . . . . . . 251<br />
L1270765 . . . . . . . . . . . . . . . . . . . . . . . . . . 251<br />
L1270766 . . . . . . . . . . . . . . . . . . . . . . 248, 250<br />
L1270767 . . . . . . . . . . . . . . . . . . . . . . . . . . 251<br />
L1270768 . . . . . . . . . . . . . . . . . . . . . . . . . . 251<br />
L1270769 . . . . . . . . . . . . . . . . . . . . . . . . . . 251<br />
L1270941 . . . . . . . . . . . . . . . . . . . . . . . . . . 250<br />
L1270942 . . . . . . . . . . . . . . . . . . . . . . . . . . 250<br />
L1270944 . . . . . . . . . . . . . . . . . . . . . . . . . . 250<br />
L1270947 . . . . . . . . . . . . . . . . . . . . . . . . . . 250<br />
L1270948 . . . . . . . . . . . . . . . . . . . . . . . . . . 250<br />
L1270949 . . . . . . . . . . . . . . . . . . . . . . . . . . 250<br />
L1270951 . . . . . . . . . . . . . . . . . . . . . . . . . . 250<br />
L1270952 . . . . . . . . . . . . . . . . . . . . . . . . . . 250<br />
L1270954 . . . . . . . . . . . . . . . . . . . . . . . . . . 250<br />
L1270957 . . . . . . . . . . . . . . . . . . . . . . . . . . 250<br />
L1270958 . . . . . . . . . . . . . . . . . . . . . . . . . . 250<br />
L1270959 . . . . . . . . . . . . . . . . . . . . . . . . . . 250<br />
L1270961 . . . . . . . . . . . . . . . . . . . . . . . . . . 250<br />
L1270962 . . . . . . . . . . . . . . . . . . . . . . . . . . 250<br />
L1270964 . . . . . . . . . . . . . . . . . . . . . . . . . . 250<br />
L1270967 . . . . . . . . . . . . . . . . . . . . . . . . . . 250<br />
L1270968 . . . . . . . . . . . . . . . . . . . . . . . . . . 250<br />
L1270969 . . . . . . . . . . . . . . . . . . . . . . . . . . 250<br />
L1270970 . . . . . . . . . . . . . . . . . . . . . . . . . . 250<br />
L1270986 . . . . . . . . . . . . . . . . . . . . . . 248, 251<br />
L1271012 . . . . . . . . . . . . . . . . . . . . . . . . . . 255<br />
L1271013 . . . . . . . . . . . . . . . . . . . . . . . . . . 255<br />
L1271021 . . . . . . . . . . . . . . . . . . . . . . . . . . 255<br />
L1271025 . . . . . . . . . . . . . . . . . . . . . . . . . . 259<br />
L1271026 . . . . . . . . . . . . . . . . . . . . . . . . . . 259<br />
L1271027 . . . . . . . . . . . . . . . . . . . . . . . . . . 259<br />
L1271102 . . . . . . . . . . . . . . . . . . . . . . 248, 250<br />
L1271191 . . . . . . . . . . . . . . . . . . . . . . . . . . 251<br />
L1271192 . . . . . . . . . . . . . . . . . . . . . . . . . . 251<br />
L1271193 . . . . . . . . . . . . . . . . . . . . . . . . . . 251<br />
L1271194 . . . . . . . . . . . . . . . . . . . . . . . . . . 251<br />
L1271195 . . . . . . . . . . . . . . . . . . . . . . . . . . 251<br />
L1271202 . . . . . . . . . . . . . . . . . . . . . . 248, 250<br />
L1271250 . . . . . . . . . . . . . . . . . . . . . . . . . . 248<br />
L1271602 . . . . . . . . . . . . . . . . . . . . . . 248, 250<br />
L1272002 . . . . . . . . . . . . . . . . . . . . . . 248, 250<br />
L1272102 . . . . . . . . . . . . . . . . . . . . . . . . . . 248<br />
L1275102 . . . . . . . . . . . . . . . . . . . . . . . . . . 255<br />
L1275105 . . . . . . . . . . . . . . . . . . . . . . . . . . 255<br />
L1275106 . . . . . . . . . . . . . . . . . . . . . . . . . . 255<br />
L1304040 . . . . . . . . . . . . . . . . . . . . . . . . . . 249<br />
L1360266 . . . . . . . . . . . . . . . . . . . . . . . . . . 255<br />
L1360267 . . . . . . . . . . . . . . . . . . . . . . . . . . 255<br />
L1360268 . . . . . . . . . . . . . . . . . . . . . . . . . . 255<br />
L1360269 . . . . . . . . . . . . . . . . . . . . . . . . . . 255<br />
L1360270 . . . . . . . . . . . . . . . . . . . . . . . . . . 255<br />
L1360271 . . . . . . . . . . . . . . . . . . . . . . . . . . 255<br />
L1360272 . . . . . . . . . . . . . . . . . . . . . . . . . . 255<br />
L1360273 . . . . . . . . . . . . . . . . . . . . . . . . . . 255<br />
L1360274 . . . . . . . . . . . . . . . . . . . . . . . . . . 256<br />
L1360275 . . . . . . . . . . . . . . . . . . . . . . . . . . 256<br />
L1362300 . . . . . . . . . . . . . . . . . . . . . . . . . . 241<br />
L1362307 . . . . . . . . . . . . . . . . . . . . . . . . . . 241<br />
L1365311 . . . . . . . . . . . . . . . . . . . . . . . . . . 257<br />
L1365312 . . . . . . . . . . . . . . . . . . . . . . . . . . 257<br />
L1860221 . . . . . . . . . . . . . . . . . . . . . . . . . . 259<br />
L1860249 . . . . . . . . . . . . . . . . . . . . . . . . . . 254<br />
L1860250 . . . . . . . . . . . . . . . . . . . . . . . . . . 254<br />
L1860268 . . . . . . . . . . . . . . . . . . . . . . . . . . 253<br />
L1860269 . . . . . . . . . . . . . . . . . . . . . . . . . . 253<br />
L1860279 . . . . . . . . . . . . . . . . . . . . . . . . . . 262<br />
L1860298 . . . . . . . . . . . . . . . . . . . . . . . . . . 265<br />
L1860305 . . . . . . . . . . . . . . . . . . . . . . . . . . 262<br />
L1860408 . . . . . . . . . . . . . . . . . . . . . . . . . . 259<br />
L1860409 . . . . . . . . . . . . . . . . . . . . . . . . . . 253<br />
L1861634 . . . . . . . . . . . . . . . . . . . . . . . . . . 253<br />
L1861789 . . . . . . . . . . . . . . . . . . . . . . 253-254<br />
L1861790 . . . . . . . . . . . . . . . . . . . . . . 253-254<br />
L1871106 . . . . . . . . . . . . . . . . . . . . . . . . . . 249<br />
L2251157 . . . . . . . . . . . . . . . . . . . . . . . . . . 315<br />
L4070023 . . . . . . . . . . . . . . . . . . . . . . . . . . 182<br />
L4070207 . . . . . . . . . . . . . . . . . . . . . . . . . . 181<br />
L4070208 . . . . . . . . . . . . . . . . . . . . . . . . . . 181<br />
L4071029 . . . . . . . . . . . . . . . . . . . . . . . . . . 181<br />
L4071034 . . . . . . . . . . . . . . . . . . . . . . . . . . 181<br />
L4071123 . . . . . . . . . . . . . . . . . . . . . . . . . . 181<br />
L4071151 . . . . . . . . . . . . . . . . . . . . . . . . . . 182<br />
L4071594 . . . . . . . . . . . . . . . . . . . . . . . . . . 181<br />
L4135472 . . . . . . . . . . . . . . . . . . . . . . . . . . 135<br />
L4270009 . . . . . . . . . . . . . . . . . . . . . . . . . . 183<br />
L4270010 . . . . . . . . . . . . . . . . . . . . . . . . . . 183<br />
L4270026 . . . . . . . . . . . . . . . . . . . . . . . . . . 182<br />
L4270032 . . . . . . . . . . . . . . . . . . . . . . . . . . 182<br />
L4270034 . . . . . . . . . . . . . . . . . . . . . . . . . . 182<br />
L4270128 . . . . . . . . . . . . . . . . . . . . . . . . . . 181<br />
L4270129 . . . . . . . . . . . . . . . . . . . . . . . . . . 181<br />
L4271106 . . . . . . . . . . . . . . . . . . . . . . . . . . 182<br />
L4271159 . . . . . . . . . . . . . . . . . . . . . . 181, 183<br />
L4271160 . . . . . . . . . . . . . . . . . . . . . . . . . . 184<br />
L4271187 . . . . . . . . . . . . . . . . . . . . . . 182-183<br />
L4271203 . . . . . . . . . . . . . . . . . . . . . . . . . . 183<br />
L4271275 . . . . . . . . . . . . . . . . . . . . . . . . . . 180<br />
L4271290 . . . . . . . . . . . . . . . . . . . . . . . . . . 183<br />
L4275009 . . . . . . . . . . . . . . . . . . . . . . . . . . 182<br />
L4275033 . . . . . . . . . . . . . . . . . . . . . . . . . . 180<br />
L4275072 . . . . . . . . . . . . . . . . . . . . . . . . . . 183<br />
L4275089 . . . . . . . . . . . . . . . . . . . . . . . . . . 182<br />
L4275107 . . . . . . . . . . . . . . . . . . . . . . . . . . 182<br />
L4275108 . . . . . . . . . . . . . . . . . . . . . . 180, 182<br />
L4275110 . . . . . . . . . . . . . . . . . . . . . . 182, 184<br />
L4280001 . . . . . . . . . . . . . . . . . . . . . . . . . . 180<br />
L4280002 . . . . . . . . . . . . . . . . . . . . . . . . . . 180<br />
L4280003 . . . . . . . . . . . . . . . . . . . . . . . . . . 180<br />
L4281023 . . . . . . . . . . . . . . . . . . . . . . . . . . 180<br />
L4285001 . . . . . . . . . . . . . . . . . . . . . . . . . . 180<br />
L4285007 . . . . . . . . . . . . . . . . . . . . . . . . . . 180<br />
L4831520 . . . . . . . . . . . . . . . . . . . . . . . . . . 241<br />
L6020211 . . . . . . . . . . . . . . . . . . . . . . . . . . 381<br />
L6020290 . . . . . . . . . . . . . . . . . . . . . . . . . . 380<br />
L6100013 . . . . . . . . . . . . . . . . . . . . . . . . . . 398<br />
L6100046 . . . . . . . . . . . . . . . . . . . . . . . . . . 398<br />
L6100047 . . . . . . . . . . . . . . . . . . . . . . . . . . 398<br />
L6100048 . . . . . . . . . . . . . . . . . . . . . . . . . . 398<br />
L6100049 . . . . . . . . . . . . . . . . . . . . . . . . . . 398<br />
L6100081 . . . . . . . . . . . . . . . . . . . . . . . . . . 400<br />
L6100082 . . . . . . . . . . . . . . . . . . . . . . . . . . 400<br />
L6100095 . . . . . . . . . . . . . . . . . . . . . . . . . . 398<br />
L6100096 . . . . . . . . . . . . . . . . . . . . . . . . . . 398<br />
L6100097 . . . . . . . . . . . . . . . . . . . . . . . . . . 398<br />
L6100098 . . . . . . . . . . . . . . . . . . . . . . . . . . 398<br />
L6100099 . . . . . . . . . . . . . . . . . . . . . . . . . . 398<br />
L6100102 . . . . . . . . . . . . . . . . . . . . . . . . . . 398<br />
L6100103 . . . . . . . . . . . . . . . . . . . . . . . . . . 398<br />
L6100104 . . . . . . . . . . . . . . . . . . . . . . . . . . 398<br />
L6100105 . . . . . . . . . . . . . . . . . . . . . . . . . . 398<br />
L6100114 . . . . . . . . . . . . . . . . . . . . . . . . . . 398<br />
L6100115 . . . . . . . . . . . . . . . . . . . . . . . . . . 398<br />
L6100116 . . . . . . . . . . . . . . . . . . . . . . . . . . 398<br />
L6100117 . . . . . . . . . . . . . . . . . . . . . . . . . . 398<br />
L6310010 . . . . . . . . . . . . . . . . . . . . . . . . . . 386<br />
L6310011 . . . . . . . . . . . . . . . . . . . . . . . . . . 386<br />
L9001029 . . . . . . . . . . . . . . . . . . . . . . 245, 256<br />
L9001162 . . . . . . . . . . . . . . . . . . . . . . . . . . 260<br />
LX100689 . . . . . . . . . . . . . . . . . . . . . . . . . . 262<br />
LX100690 . . . . . . . . . . . . . . . . . . . . . . . . . . 262<br />
LX100846 . . . . . . . . . . . . . . . . . . . . . . . . . . 263<br />
Part No. Page Part No. Page Part No. Page
LX100847 – N0772026 Part Number Index<br />
Index<br />
Part Number<br />
415<br />
LX100847 . . . . . . . . . . . . . . . . . . . . . . . . . . 264<br />
LX100849 . . . . . . . . . . . . . . . . . . . . . . . . . . 263<br />
LX100850 . . . . . . . . . . . . . . . . . . . . . . . . . . 264<br />
LX108640 . . . . . . . . . . . . . . . . . . . . . . . . . . 262<br />
LX108689 . . . . . . . . . . . . . . . . . . . . . . . . . . 263<br />
LX108848 . . . . . . . . . . . . . . . . . . . . . . . . . . 263<br />
LX108849 . . . . . . . . . . . . . . . . . . . . . . . . . . 264<br />
LX108850 . . . . . . . . . . . . . . . . . . . . . . . . . . 264<br />
M0410316 . . . . . . . . . . . . . . . . . . . . . . 183-184<br />
M0413331 . . . . . . . . . . . . . . . . . . . . . . . . . 183<br />
M0413348 . . . . . . . . . . . . . . . . . . . . . . . . . 145<br />
M0413380 . . . . . . . . . . . . . . . . . . . . . . . . . 183<br />
M0413401 . . . . . . . . . . . . . . . . . . . . . . . . . 144<br />
M0413535 . . . . . . . . . . . . . . . . . . . . . . . . . 184<br />
M0413541 . . . . . . . . . . . . . . . . . . . . . . . . . 182<br />
M0413545 . . . . . . . . . . . . . . . . . . . . . . . . . 147<br />
M0413546 . . . . . . . . . . . . . . . . . . . . . . . . . 147<br />
M0413547 . . . . . . . . . . . . . . . . . . . . . . . . . 147<br />
M0413548 . . . . . . . . . . . . . . . . . . . . . . . . . 143<br />
M0413549 . . . . . . . . . . . . . . . . . . . . . . . . . 143<br />
M0413550 . . . . . . . . . . . . . . . . . . . . . . . . . 143<br />
M0413551 . . . . . . . . . . . . . . . . . . . . . 143, 184<br />
M0413552 . . . . . . . . . . . . . . . . . . . . . . . . . 144<br />
M0413553 . . . . . . . . . . . . . . . . . . . . . . . . . 184<br />
M0413555 . . . . . . . . . . . . . . . . . . . . . . . . . 184<br />
M0413556 . . . . . . . . . . . . . . . . . . . . . . . . . 184<br />
M0413557 . . . . . . . . . . . . . . . . . . . . . . . . . 184<br />
M0413558 . . . . . . . . . . . . . . . . . . . . . . . . . 183<br />
M0413559 . . . . . . . . . . . . . . . . . . . . . . . . . 183<br />
M0413592 . . . . . . . . . . . . . . . . . . . . . . . . . 145<br />
M0413593 . . . . . . . . . . . . . . . . . . . . . . . . . 145<br />
M0413595 . . . . . . . . . . . . . . . . . . . . . . . . . 181<br />
M0413596 . . . . . . . . . . . . . . . . . . . . . . . . . 181<br />
M0413597 . . . . . . . . . . . . . . . . . . . . . . . . . 181<br />
M0413598 . . . . . . . . . . . . . . . . . . . . . . . . . 181<br />
M0413625 . . . . . . . . . . . . . . . . . . . . . . . . . 181<br />
M0413627 . . . . . . . . . . . . . . . . . . . . . . . . . 184<br />
M0413628 . . . . . . . . . . . . . . . . . . . . . . . . . 184<br />
M0413643 . . . . . . . . . . . . . . . . . . . . . . . . . 144<br />
M0413644 . . . . . . . . . . . . . . . . . . . . . . . . . 183<br />
M0413645 . . . . . . . . . . . . . . . . . . . . . . . . . 183<br />
M0413646 . . . . . . . . . . . . . . . . . . . . . . . . . 184<br />
M0415339 . . . . . . . . . . . . . . . . . . . . . . . . . 183<br />
M0415360 . . . . . . . . . . . . . . . . . . . . . . . . . 184<br />
M0415361 . . . . . . . . . . . . . . . . . . . . . . . . . 184<br />
N0171159 . . . . . . . . . . . . . . . . . . . . . . . . . . 240<br />
N0200015 . . . . . . . . . . . . . . . . . . . . . . . . . . 346<br />
N0370119 . . . . . . . . . . . . . . . . . . . . . . . . . . . 45<br />
N0370149 . . . . . . . . . . . . . . . . . . . . . . . . . . . 14<br />
N0370392 . . . . . . . . . . . . . . . . . . . . . . . . . . . 13<br />
N0370393 . . . . . . . . . . . . . . . . . . . . . . . . 17-18<br />
N0370394 . . . . . . . . . . . . . . . . . . . . . . . . 17-18<br />
N0370398 . . . . . . . . . . . . . . . . . . . . . . . . . . . 18<br />
N0370399 . . . . . . . . . . . . . . . . . . . . . . . . . . . 18<br />
N0371485 . . . . . . . . . . . . . . . . . . . . . . . . . . . 18<br />
N0371492 . . . . . . . . . . . . . . . . . . . . . . . . . . . 18<br />
N0371493 . . . . . . . . . . . . . . . . . . . . . . . . . . . 18<br />
N0371505 . . . . . . . . . . . . . . . . . . . . . . . 18, 222<br />
N0371520 . . . . . . . . . . . . . . . . . . . . . . . . . . . 18<br />
N0371522 . . . . . . . . . . . . . . . . . . . . . . . . . . . 18<br />
N0400058 . . . . . . . . . . . . . . . . . . . . . . . . . . . 13<br />
N0400100 . . . . . . . . . . . . . . . . . . . . . . . . . . . 13<br />
N0400101 . . . . . . . . . . . . . . . . . . . . . . . . . . . 13<br />
N0400102 . . . . . . . . . . . . . . . . . . . . . . . . . . . 13<br />
N0400103 . . . . . . . . . . . . . . . . . . . . . . . . . . . 13<br />
N0401171 . . . . . . . . . . . . . . . . . . . . . . . . . . . 13<br />
N0410100 . . . . . . . . . . . . . . . . . . . . . . . . . . . 48<br />
N0580528 . . . . . . . . . . . . . . . . . . . . . . . . . . 227<br />
N0580531 . . . . . . . . . . . . . . . . . . . . . . . . . . . 36<br />
N0580534 . . . . . . . . . . . . . . . . . . . . . . . . . . 229<br />
N0580539 . . . . . . . . . . . . . . . . . . . . . . 220, 228<br />
N0580540 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9<br />
N0580542 . . . . . . . . . . . . . . . . . . . . . . . . . . 226<br />
N0580624 . . . . . . . . . . . . . . . . . . . . . . 197, 223<br />
N0581455 . . . . . . . . . . . . . . . . . . . . . . . . . . 219<br />
N0581497 . . . . . . . . . . . . . . . . . . . . . . . . . . 219<br />
N0581558 . . . . . . . . . . . . . . . . . . . . . . . . . . 229<br />
N0581793 . . . . . . . . . . . . . . . . . . . . . . . . . . 229<br />
N0582152 . . . . . . . . . . . . . . . . . . . . . . . . . . 236<br />
N0582184 . . . . . . . . . . . . . . . . . . . . . . 220, 229<br />
N0582185 . . . . . . . . . . . . . . . . . . . . . . . . . . 220<br />
N0582186 . . . . . . . . . . . . . . . . . . . . . . . . . . 220<br />
N0582248 . . . . . . . . . . . . . . . . . . . . . . . . . . 220<br />
N0582251 . . . . . . . . . . . . . . . . . . . . . . . 36, 216<br />
N0582258 . . . . . . . . . . . . . . . . . . . . . . 226, 229<br />
N0582259 . . . . . . . . . . . . . . . . . . . . . . . . . . 226<br />
N0650230 . . . . . . . . . . . . . . . . . . . . . . . . . . 218<br />
N0660122 . . . . . . . . . . . . . . . . . . . . . . . . . . . 44<br />
N0660123 . . . . . . . . . . . . . . . . . . . . . . . . . . . 44<br />
N0680212 . . . . . . . . . . . . . . . . . . . . . . . . . . 219<br />
N0680241 . . . . . . . . . . . . . . . . . . . . . . . . . . 228<br />
N0680275 . . . . . . . . . . . . . . . . . . . . . . . . . . 219<br />
N0680375 . . . . . . . . . . . . . . . . . . . . . . 199, 224<br />
N0680376 . . . . . . . . . . . . . . . . . . . . . . 199, 224<br />
N0680503 . . . . . . . . . . . . . . . . . . . . . . 223, 229<br />
N0680504 . . . . . . . . . . . . . . 197, 218, 221-222<br />
N0680610 . . . . . . . . . . . . . . . . . . . . . . . . . . 223<br />
N0680612 . . . . . . . . . . . . . . . . . . . . . . . . . . 198<br />
N0681234 . . . . . . . . . . . . . . . . . . . . . . . . . . 219<br />
N0681470 . . . . . . . . . . . . . . . . . . . . . . . . . . 236<br />
N0681574 . . . . . . . . . . . . . . . . . . . . . . 196, 221<br />
N0681581 . . . . . . . . . . . . . . . . . . . . . . . . . . 236<br />
N0681631 . . . . . . . . . . . . . . . . . . . . . . 195, 220<br />
N0681690 . . . . . . . . . . . . . . . . . . . . . . . . . . 227<br />
N0690262 . . . . . . . . . . . . . . . . . . . . . . . . . . 224<br />
N0690269 . . . . . . . . . . . . . . . . . . . . . . 220, 228<br />
N0690271 . . . . . . . . . . . . . . . . . . . . . . 204, 218<br />
N0690284 . . . . . . . . . . . . . . . . . . . . . . . . . . 224<br />
N0690287 . . . . . . . . . . . . . . . . . . . . . . . . . . 218<br />
N0690288 . . . . . . . . . . . . . . . . . . . . . . . . . . 218<br />
N0690289 . . . . . . . . . . . . . . . . . . . . . . . . . . 226<br />
N0690360 . . . . . . . . . . . . . . . . . . . . . . . . . . 224<br />
N0690568 . . . . . . . . . . . . . . . . . . . . . . 227, 229<br />
N0690572 . . . . . . . . . . . . . . . . . . . . . . . . . . 219<br />
N0690593 . . . . . . . . . . . . . . . . . . . . . . . . . . 229<br />
N0690607 . . . . . . . . . . . . . . . . . . . . . . 228-230<br />
N0690610 . . . . . . . . . . . . . . . . . . . . . . . . . . 227<br />
N0690636 . . . . . . . . . . . . . . . . . . . . . . . . . . 227<br />
N0690637 . . . . . . . . . . . . . . . . . . . . . . . . . . 228<br />
N0690638 . . . . . . . . . . . . . . . . . . . . . . . . . . 228<br />
N0690639 . . . . . . . . . . . . . . . . . . . . . . . . . . 224<br />
N0690640 . . . . . . . . . . . . . . . . . . . . . . . . . . 226<br />
N0690666 . . . . . . . . . . . . . . . . . . . . . . . . . . 219<br />
N0690668 . . . . . . . . . . . . . . . . . . . . . . . . . . 219<br />
N0690670 . . . . . . . . . . . . . . . . . . . . . . . . . . 222<br />
N0690671 . . . . . . . . . . . . . . . . . . . . . . . . . . 222<br />
N0690672 . . . . . . . . . . . . . . . . . . . . . . . . . . 219<br />
N0690673 . . . . . . . . . . . . . . . . . . . . . . . . . . 224<br />
N0690676 . . . . . . . . . . . . . . . . . . . . . . . . . . 223<br />
N0690677 . . . . . . . . . . . . . . . . . . . . . . . . . . 226<br />
N0690712 . . . . . . . . . . . . . . . . . . . . . . . . . . 227<br />
N0690720 . . . . . . . . . . . . . . . . . . . . . . . . . . 226<br />
N0690769 . . . . . . . . . . . . . . . . . . . . . . 220, 228<br />
N0690770 . . . . . . . . . . . . . . . . . . . . . . . . . . 228<br />
N0690772 . . . . . . . . . . . . . . . . . . . . . . . . . . 219<br />
N0690780 . . . . . . . . . . . . . . . . . . . . . . 220, 229<br />
N0690812 . . . . . . . . . . . . . . . . . . . . . . . . . . 227<br />
N0691182 . . . . . . . . . . . . . . . . . . . . . . . . . . 219<br />
N0691578 . . . . . . . . . . . . . . . . . . . . . . . . . . 217<br />
N0691579 . . . . . . . . . . . . . . . . . . . . . . . . . . 235<br />
N0691580 . . . . . . . . . . . . . . . . . . . . . . . . . . 233<br />
N0691581 . . . . . . . . . . . . . . . . . . . . . . . . . . 233<br />
N0691595 . . . . . . . . . . . . . . . . . . . . . . . . . . 224<br />
N0691662 . . . . . . . . . . . . . . . . . . . . . . 227, 229<br />
N0691664 . . . . . . . . . . . . . . . . . . . . . . . . . . 227<br />
N0691689 . . . . . . . . . . . . . . . . . . . . . . . . . . 219<br />
N0691702 . . . . . . . . . . . . . . . . . . . . . . . . . . 198<br />
N0691709 . . . . . . . . . . . . . . . . . . . . . . 199, 221<br />
N0691710 . . . . . . . . . . . . . . . . . . . . . . 199, 221<br />
N0691883 . . . . . . . . . . . . . . . . . . . . . . . . . . 217<br />
N0691884 . . . . . . . . . . . . . . . . . . . . . . . . . . 217<br />
N0695214 . . . . . . . . . . . . . . . . . . . . . . 220, 229<br />
N0695219 . . . . . . . . . . . . . . . . . . . . . . . . . . 219<br />
N0695220 . . . . . . . . . . . . . . . . . . . . . . . . . . 229<br />
N0695222 . . . . . . . . . . . . . . . . . . . . . . 226, 229<br />
N0695225 . . . . . . . . . . . . . . . . . . . . . . . . . . 229<br />
N0695233 . . . . . . . . . . . . . . . . . . . . . . . . . . 219<br />
N0695238 . . . . . . . . . . . . . . . . . . . . . . . . . . 229<br />
N0695295 . . . . . . . . . . . . . . . . . . . . . . . . . . 227<br />
N0695362 . . . . . . . . . . . . . . . . . . 220, 229-230<br />
N0695367 . . . . . . . . . . . . . . . . . . . . . . . . . . 230<br />
N0695368 . . . . . . . . . . . . . . . . . . . . . . . . . . 226<br />
N0695379 . . . . . . . . . . . . . . . . . . . . . . 227, 229<br />
N0695381 . . . . . . . . . . . . . . . . . . . . . . . . . . 230<br />
N0695400 . . . . . . . . . . . . . . . . . . 220, 229-230<br />
N0695414 . . . . . . . . . . . . . . . . . . . . . . . . . . 226<br />
N0695426 . . . . . . . . . . . . . . . . . . . . . . . . . . 226<br />
N0695433 . . . . . . . . . . . . . . . . . . . . . . . . . . 226<br />
N0695441 . . . . . . . . . . . . . . . . . . . . . . . . . . 220<br />
N0695442 . . . . . . . . . . . . . . . . . . . . . . . . . . 220<br />
N0695448 . . . . . . . . . . . . . . . . . . . . . . . . . . 220<br />
N0695449 . . . . . . . . . . . . . . . . . . . . . . . . . . 220<br />
N0695456 . . . . . . . . . . . . . . . . . . . . . . . . . . 227<br />
N0695460 . . . . . . . . . . . . . . . . . . . . . . 220, 226<br />
N0695461 . . . . . . . . . . . . . . . . . . . . . . . . . . 220<br />
N0695468 . . . . . . . . . . . . . . . . . . . . . . . . . . 216<br />
N0695469 . . . . . . . . . . . . . . . . . . . . . . . . . . 216<br />
N0695470 . . . . . . . . . . . . . . . . . . . . . . . . . . 216<br />
N0695471 . . . . . . . . . . . . . . . . . . . . . . . . . . 216<br />
N0695472 . . . . . . . . . . . . . . . . . . . . . . . . . . 216<br />
N0695473 . . . . . . . . . . . . . . . . . . . . . . . . . . 216<br />
N0695474 . . . . . . . . . . . . . . . . . . . . . . . . . . 216<br />
N0695475 . . . . . . . . . . . . . . . . . . . . . . . . . . 216<br />
N0695477 . . . . . . . . . . . . . . . . . . . . . . . . . . 205<br />
N0695494 . . . . . . . . . . . . . . . . . . . . . . . . . . 220<br />
N0695495 . . . . . . . . . . . . . . . . . . . . . . 195, 220<br />
N0770198 . . . . . . . . . . . . . . . . . . . . . . . . . . 216<br />
N0770322 . . . . . . . . . . . . . . . . . . . . . . . . . . 219<br />
N0770338 . . . . . . . . . . . . . . . . . . . . . . . . . . 227<br />
N0770343 . . . . . . . . . . . . . . . . . . . . . . . . . . 227<br />
N0770344 . . . . . . . . . . . . . . . . . . . . . . . . . . 227<br />
N0770357 . . . . . . . . . . . . . . . . . . . . . . . . . . 226<br />
N0770358 . . . . . . . . . . . . . . . . . . . . . . . . . . 222<br />
N0770434 . . . . . . . . . . . . . . . . . . . . . . . . . . 217<br />
N0770437 . . . . . . . . . . . . . . . . . . . . . . . . . . 228<br />
N0770438 . . . . . . . . . . . . . . . . . . . . . . . . . . 220<br />
N0770546 . . . . . . . . . . . . . . . . . . . . . . . . . . 223<br />
N0770600 . . . . . . . . . . . . . . . . . . . . . . . . . . 227<br />
N0770603 . . . . . . . . . . . . . . . . . . . . . . . . . . 220<br />
N0770606 . . . . . . . . . . . . . . . . . . . . . . . . . . 227<br />
N0770607 . . . . . . . . . . . . . . . . . . . . . . . . . . 227<br />
N0770608 . . . . . . . . . . . . . . . . . . . . . . . . . . 228<br />
N0770609 . . . . . . . . . . . . . . . . . . . . . . . . . . 227<br />
N0770910 . . . . . . . . . . . . . . . . . . . . . . . . . . 228<br />
N0770911 . . . . . . . . . . . . . . . . . . . . . . . . . . 228<br />
N0771116 . . . . . . . . . . . . . . . . . . . . . . . . . . 219<br />
N0771500 . . . . . . . . . . . . . . . . . . . . . . . . . . 227<br />
N0771501 . . . . . . . . . . . . . . . . . . . . . . . . . . 225<br />
N0771526 . . . . . . . . . . . . . . . . . . . . . . . . . . 220<br />
N0771527 . . . . . . . . . . . . . . . . . . . . . . . . . . 220<br />
N0771529 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9<br />
N0771531 . . . . . . . . . . . . . . . . . . . . . . . . . . 220<br />
N0771536 . . . . . . . . . . . . . . . . . . . . . . . . . . 219<br />
N0771550 . . . . . . . . . . . . . . . . . . . . . . . . . . 225<br />
N0772025 . . . . . . . . . . . . . . . . . . . . . . 189, 217<br />
N0772026 . . . . . . . . . . . . . . . . . . . . . . 189, 217<br />
Part No. Page Part No. Page Part No. Page<br />
See page 4 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
See page 2 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong>
Index Part Number N0775014 – N2910344<br />
Index<br />
Part Number<br />
416<br />
N0775014 . . . . . . . . . . . . . . . . . . . . . . . . . . 220<br />
N0775177 . . . . . . . . . . . . . . . . . . . . . . . . . . 220<br />
N0775220 . . . . . . . . . . . . . . . . . . . . . . . . . . 216<br />
N0775223 . . . . . . . . . . . . . . . . . . . . . . . . . . 220<br />
N0775224 . . . . . . . . . . . . . . . . . . . . . . . . . . 220<br />
N0775225 . . . . . . . . . . . . . . . . . . . . . . . . . . 220<br />
N0775226 . . . . . . . . . . . . . . . . . . . . . . . . . . 220<br />
N0775227 . . . . . . . . . . . . . . . . . . . . . . . . . . 220<br />
N0775228 . . . . . . . . . . . . . . . . . . . . . . . . . . 220<br />
N0775247 . . . . . . . . . . . . . . . . . . . . . . . . . . 220<br />
N0775289 . . . . . . . . . . . . . . . . . . . . . . . . . . 227<br />
N0775297 . . . . . . . . . . . . . . . . . . . . . . . . . . 228<br />
N0775300 . . . . . . . . . . . . . . . . . . . . . . . . . . 219<br />
N0775330 . . . . . . . . . . . . . . . . . . . . . . . . . . 222<br />
N0775331 . . . . . . . . . . . . . . . . . . . . . . . . . . 218<br />
N0775340 . . . . . . . . . . . . . . . . . . . . . . 197, 222<br />
N0775341 . . . . . . . . . . . . . . . . . . . . . . 197, 222<br />
N0775342 . . . . . . . . . . . . . . . . . . . . . . 197, 222<br />
N0775343 . . . . . . . . . . . . . . . . . . . . . . 197, 222<br />
N0775344 . . . . . . . . . . . . . . . . . . . . . . 197, 222<br />
N0775345 . . . . . . . . . . . . . . . . . . . . . . . . . . 222<br />
N0775346 . . . . . . . . . . . . . . . . . . . . . . . . . . 221<br />
N0775347 . . . . . . . . . . . . . . . . . . . . . . . . . . 221<br />
N0775348 . . . . . . . . . . . . . . . . . . . . . . . . . . 221<br />
N0775349 . . . . . . . . . . . . . . . . . . . . . . . . . . 221<br />
N0775350 . . . . . . . . . . . . . . . . . . . . . . 203, 225<br />
N0775351 . . . . . . . . . . . . . . . . . . . . . . . . . . 225<br />
N0775352 . . . . . . . . . . . . . . . . . . . . . . . . . . 225<br />
N0775353 . . . . . . . . . . . . . . . . . . . . . . . . . . 202<br />
N0775354 . . . . . . . . . . . . . . . . . . . . . . . . . . 203<br />
N0775355 . . . . . . . . . . . . . . . . . . . . . . . . . . 225<br />
N0775356 . . . . . . . . . . . . . . . . . . . . . . . . . . 225<br />
N0775357 . . . . . . . . . . . . . . . . . . . . . . . . . . 225<br />
N0775358 . . . . . . . . . . . . . . . . . . . . . . . . . . 219<br />
N0776052 . . . . . . . . . . . . . . . . . . . . . . . . . . 225<br />
N0776053 . . . . . . . . . . . . . . . . . . . . . . . . . . 225<br />
N0776099 . . . . . . . . . . . . . . . . . . . . . . . . . . 217<br />
N0911028 . . . . . . . . . . . . . . . . . . . . . . . . . . 323<br />
N0911038 . . . . . . . . . . . . . . . . . . . . . . . . . . 323<br />
N0911041 . . . . . . . . . . . . . . . . . . . . . . . . . . 325<br />
N1010047 . . . . . . . . . . . . . . . . . . . . . . . . . . 143<br />
N1010048 . . . . . . . . . . . . . . . . . . . . . . . . . . 144<br />
N1010050 . . . . . . . . . . . . . . . . . . . . . . . . . . 143<br />
N1010070 . . . . . . . . . . . . . . . . . . . . . . . . . . 148<br />
N1010200 . . . . . . . . . . . . . . . . . . . . . . . . . . . 71<br />
N1010202 . . . . . . . . . . . . . . . . . . . . . . . . . . . 71<br />
N1010215 . . . . . . . . . . . . . . . . . . . . . . . . 13, 18<br />
N1010230 . . . . . . . . . . . . . . . . . . . . . . . . . . . 71<br />
N1010504 . . . . . . . . . . . . . . . . . . . . . . . . . . 396<br />
N1010520 . . . . . . . . . . . . . . . . . . . . . . . . . . 382<br />
N1010539 . . . . . . . . . . . . . . . . . . . . . . . . . . 396<br />
N1010540 . . . . . . . . . . . . . . . . . . . . . . . . . . 396<br />
N1010565 . . . . . . . . . . . . . . . . . . . . . . . . . . 385<br />
N1010566 . . . . . . . . . . . . . . . . . . . . . . . . . . 385<br />
N1010567 . . . . . . . . . . . . . . . . . . . . . . . . . . 387<br />
N1010568 . . . . . . . . . . . . . . . . . . . . . . . . . . 387<br />
N1010569 . . . . . . . . . . . . . . . . . . . . . . . . . . 387<br />
N1011206 . . . . . . . . . . . . . . . . . . . . . . . . . . 147<br />
N1011210 . . . . . . . . . . . . . . . . . . . . . . . . . . 144<br />
N1011445 . . . . . . . . . . . . . . . . . . 144, 150, 157<br />
N1011446 . . . . . . . . . . 144, 150, 155, 157-158<br />
N1011447 . . . . . . . . . . . . . . . . . . 144, 155, 158<br />
N1015158 . . . . . . . . . . . . . . . . . . . . . . . . . . 386<br />
N1016001 . . . . . . . . . . . . . . . . . . . . . . . . . . 384<br />
N1016008 . . . . . . . . . . . . . . . . . . . . . . . . . . 384<br />
N1016015 . . . . . . . . . . . . . . . . . . . . . . . . . . 384<br />
N1016030 . . . . . . . . . . . . . . . . . . . . . . . . . . 384<br />
N1016045 . . . . . . . . . . . . . . . . . . . . . . . . . . 384<br />
N1016060 . . . . . . . . . . . . . . . . . . . . . . . . . . 384<br />
N1016070 . . . . . . . . . . . . . . . . . . . . . . . . . . 380<br />
N1016071 . . . . . . . . . . . . . . . . . . . . . . . . . . 380<br />
N1016072 . . . . . . . . . . . . . . . . . . . . . . . . . . 380<br />
N1016073 . . . . . . . . . . . . . . . . . . . . . . . . . . 380<br />
N1016074 . . . . . . . . . . . . . . . . . . . . . . . . . . 380<br />
N1870151 . . . . . . . . . . . . . . . . . . . . . . . . . . 253<br />
N1870184 . . . . . . . . . . . . . . . . . . . . . . . . . . 254<br />
N1870185 . . . . . . . . . . . . . . . . . . . . . . . . . . 254<br />
N1870188 . . . . . . . . . . . . . . . . . . . . . . . . . . 254<br />
N1873124 . . . . . . . . . . . . . . . . . . . . . . . . . . 254<br />
N2010381 . . . . . . . . . . . . . . . . . . . . . . . . . . . 13<br />
N2011074 . . . . . . . . . . . . . . . . . . . . . . . . . . . 13<br />
N2350014 . . . . . . . . . . . . . . . . . . . . . . . . . . 314<br />
N2350211 . . . . . . . . . . . . . . . . . . . . . . . . . . 314<br />
N2351285 . . . . . . . . . . . . . . . . . . . . . . . . . . 314<br />
N2410021 . . . . . . . . . . . . . . . . . . . . . . . . . . . 77<br />
N2410022 . . . . . . . . . . . . . . . . . . . . . . . . . . . 77<br />
N2410092 . . . . . . . . . . . . . . . . . . . . . . . . . . . 78<br />
N2410141 . . . . . . . . . . . . . . . . . . . . . . . . . . . 77<br />
N2410145 . . . . . . . . . . . . . . . . . . . . . . . . 76, 78<br />
N2410146 . . . . . . . . . . . . . . . . . . . . . . . . . . . 80<br />
N2410147 . . . . . . . . . . . . . . . . . . . . . . . 77, 355<br />
N2410153 . . . . . . . . . . . . . . . . . . . . . . . . . . . 79<br />
N2410154 . . . . . . . . . . . . . . . . . . . . . . . . . . . 79<br />
N2410155 . . . . . . . . . . . . . . . . . . . . . . . . . . . 80<br />
N2410157 . . . . . . . . . . . . . . . . . . . . . . . . . . . 78<br />
N2410164 . . . . . . . . . . . . . . . . . . . . . . . . . . . 78<br />
N2410165 . . . . . . . . . . . . . . . . . . . . . . . . . . . 78<br />
N2410166 . . . . . . . . . . . . . . . . . . . . . . . . . . . 78<br />
N2410170 . . . . . . . . . . . . . . . . . . . . . . . 77, 354<br />
N2410172 . . . . . . . . . . . . . . . . . . . . . . . . . . . 77<br />
N2410173 . . . . . . . . . . . . . . . . . . . . . . . . . . . 77<br />
N2410174 . . . . . . . . . . . . . . . . . . . . . . . . . . . 77<br />
N2410177 . . . . . . . . . . . . . . . . . . . . . . . . . . . 79<br />
N2410188 . . . . . . . . . . . . . . . . . . . . . . . . . . . 78<br />
N2410189 . . . . . . . . . . . . . . . . . . . . . . . . . . . 76<br />
N2410191 . . . . . . . . . . . . . . . . . . . . . . . . . . . 78<br />
N2410212 . . . . . . . . . . . . . . . . . . . . . . . . . . . 79<br />
N2410237 . . . . . . . . . . . . . . . . . . . . . . . . . . . 81<br />
N2410244 . . . . . . . . . . . . . . . . . . . . . . . . . . . 80<br />
N2410248 . . . . . . . . . . . . . . . . . . . . . . . . . . . 77<br />
N2410265 . . . . . . . . . . . . . . . . . . . . . . . . . . . 76<br />
N2410277 . . . . . . . . . . . . . . . . . . . . . . . . . . . 78<br />
N2410278 . . . . . . . . . . . . . . . . . . . . . . . . . . . 78<br />
N2410315 . . . . . . . . . . . . . . . . . . . . . . . . . . . 81<br />
N2410320 . . . . . . . . . . . . . . . . . . . . . . . . . . . 80<br />
N2410324 . . . . . . . . . . . . . . . . . . . . . . . . 76, 80<br />
N2410325 . . . . . . . . . . . . . . . . . . . . . . . . . . . 80<br />
N2410327 . . . . . . . . . . . . . . . . . . . . . . . . . . . 77<br />
N2410330 . . . . . . . . . . . . . . . . . . . . . . . . . . . 79<br />
N2410331 . . . . . . . . . . . . . . . . . . . . . . . . . . . 78<br />
N2410332 . . . . . . . . . . . . . . . . . . . . . . . . . . . 78<br />
N2410360 . . . . . . . . . . . . . . . . . . . . . . . . . . . 77<br />
N2410361 . . . . . . . . . . . . . . . . . . . . . . . . . . . 77<br />
N2410365 . . . . . . . . . . . . . . . . . . . . . . . . . . . 77<br />
N2410501 . . . . . . . . . . . . . . . . . . . . . . . . 76, 80<br />
N2410502 . . . . . . . . . . . . . . . . . . . . . . . . . . . 77<br />
N2410503 . . . . . . . . . . . . . . . . . . . . . . . . . . . 77<br />
N2410506 . . . . . . . . . . . . . . . . . . . . . . . . . . . 76<br />
N2410507 . . . . . . . . . . . . . . . . . . . . . . . . . . . 76<br />
N2410513 . . . . . . . . . . . . . . . . . . . . . . . . . . . 76<br />
N2410518 . . . . . . . . . . . . . . . . . . . . . . . . . . . 78<br />
N2410680 . . . . . . . . . . . . . . . . . . . . . . . . . . . 78<br />
N2410681 . . . . . . . . . . . . . . . . . . . . . . . . . . . 78<br />
N2410682 . . . . . . . . . . . . . . . . . . . . . . . . 76, 78<br />
N2410683 . . . . . . . . . . . . . . . . . . . . . . . . 76, 78<br />
N2410684 . . . . . . . . . . . . . . . . . . . . . . . . . . . 78<br />
N2411019 . . . . . . . . . . . . . . . . . . . . . . . . . . . 82<br />
N2411087 . . . . . . . . . . . . . . . . . . . . . . . . . . . 83<br />
N2411088 . . . . . . . . . . . . . . . . . . . . . . . . . . . 83<br />
N2411117 . . . . . . . . . . . . . . . . . . . . . . . . . . . 81<br />
N2411118 . . . . . . . . . . . . . . . . . . . . . . . . . . . 81<br />
N2411144 . . . . . . . . . . . . . . . . . . . . . . . . . . . 82<br />
N2411235 . . . . . . . . . . . . . . . . . . . . . . . . 76, 79<br />
N2411255 . . . . . . . . . . . . . . . . . . . . . . . . . . . 80<br />
N2411257 . . . . . . . . . . . . . . . . . . . . . . . . . . . 83<br />
N2411264 . . . . . . . . . . . . . . . . . . . . . . . . . . . 79<br />
N2411267 . . . . . . . . . . . . . . . . . . . . . . . . . . . 80<br />
N2411273 . . . . . . . . . . . . . . . . . . . . . . . . 76, 78<br />
N2411274 . . . . . . . . . . . . . . . . . . . . . . . . . . . 82<br />
N2411291 . . . . . . . . . . . . . . . . . . . . . . . . . . . 79<br />
N2411300 . . . . . . . . . . . . . . . . . . . . . . . . 76, 79<br />
N2411333 . . . . . . . . . . . . . . . . . . . . . . . . 76, 78<br />
N2411335 . . . . . . . . . . . . . . . . . . . . . . . . . . . 79<br />
N2411341 . . . . . . . . . . . . . . . . . . . . . . . . . . . 81<br />
N2411342 . . . . . . . . . . . . . . . . . . . . . . . . . . . 81<br />
N2411359 . . . . . . . . . . . . . . . . . . . . . 76, 79, 82<br />
N2411362 . . . . . . . . . . . . . . . . . . . . . . . . . . . 80<br />
N2411363 . . . . . . . . . . . . . . . . . . . . . . . . . . . 80<br />
N2411364 . . . . . . . . . . . . . . . . . . . . . . . . . . . 80<br />
N2411374 . . . . . . . . . . . . . . . . . . . . . . . . . . . 83<br />
N2411401 . . . . . . . . . . . . . . . . . . . . . . . . 76, 79<br />
N2411487 . . . . . . . . . . . . . . . . . . . . . . . . . . . 79<br />
N2411514 . . . . . . . . . . . . . . . . . . . . . . . . . . . 79<br />
N2411527 . . . . . . . . . . . . . . . . . . . . . . . . . . . 78<br />
N2420212 . . . . . . . . . . . . . . . . . . . . . . . . . . . 76<br />
N2420214 . . . . . . . . . . . . . . . . . . . . . . . . . . . 81<br />
N2421070 . . . . . . . . . . . . . . . . . . . . . . . . . . . 79<br />
N2580003 . . . . . . . . . . . . . . . . . . . . . . . . . . 285<br />
N2580012 . . . . . . . . . . . . . . . . . . . . . . . . . . 285<br />
N2580013 . . . . . . . . . . . . . . . . . . . . . . . . . . 285<br />
N2580020 . . . . . . . . . . . . . . . . . . . . . . . . . . 285<br />
N2580021 . . . . . . . . . . . . . . . . . . . . . . . . . . 285<br />
N2580022 . . . . . . . . . . . . . . . . . . . . . . . . . . 285<br />
N2580030 . . . . . . . . . . . . . . . . . . . . . . . . . . 293<br />
N2580042 . . . . . . . . . . . . . . . . . . . . . . . . . . 285<br />
N2600070 . . . . . . . . . . . . . . . . . . . . . . . . . . 322<br />
N2600089 . . . . . . . . . . . . . . . . . . . . . . 273, 322<br />
N2600104 . . . . . . . . . . . . . . . . . . . . . . 319-320<br />
N2600124 . . . . . . . . . . . . . . . . . . . . . . 319-320<br />
N2600192 . . . . . . . . . . . . . . . . . . . . . . 319-320<br />
N2600226 . . . . . . . . . . . . . . . . . . . . . . 319-320<br />
N2600259 . . . . . . . . . . . . . . . . . . . . . . . . . . 322<br />
N2600284 . . . . . . . . . . . . . . . . . . . . . . . . . . 318<br />
N2600313 . . . . . . . . . . . . . . . . . . . . . . . . . . 321<br />
N2600456 . . . . . . . . . . . . . . . . . . . . . . . . . . 318<br />
N2600457 . . . . . . . . . . . . . . . . . . . . . . . . . . 318<br />
N2600458 . . . . . . . . . . . . . . . . . . . . . . . . . . 318<br />
N2600459 . . . . . . . . . . . . . . . . . . . . . . . . . . 318<br />
N2600491 . . . . . . . . . . . . . . . . . . . . . . . . . . 318<br />
N2600495 . . . . . . . . . . . . . . . . . . . . . . . . . . 318<br />
N2600496 . . . . . . . . . . . . . . . . . . . . . . . . . . 318<br />
N2600497 . . . . . . . . . . . . . . . . . . . . . . . . . . 318<br />
N2600498 . . . . . . . . . . . . . . . . . . . . . . . . . . 318<br />
N2600499 . . . . . . . . . . . . . . . . . . . . . . . . . . 318<br />
N2600505 . . . . . . . . . . . . . . . . . . . . . . . . . . 318<br />
N2600506 . . . . . . . . . . . . . . . . . . . . . . . . . . 318<br />
N2600570 . . . . . . . . . . . . . . . . . . . . . . . . . . 318<br />
N2600571 . . . . . . . . . . . . . . . . . . . . . . . . . . 318<br />
N2601149 . . . . . . . . . . . . . . . . . . . . . . . . . . 323<br />
N2601174 . . . . . . . . . . . . . . . . . . . . . . 319-320<br />
N2601189 . . . . . . . . . . . . . . . . . . . . . . . . . . 318<br />
N2601262 . . . . . . . . . . . . . . . . . . . . . . . . . . 322<br />
N2601295 . . . . . . . . . . . . . . . . . . . . . . . . . . 321<br />
N2601313 . . . . . . . . . . . . . . . . . . . . . . . . . . 321<br />
N2601316 . . . . . . . . . . . . . . . . . . . . . . . . . . 321<br />
N2601346 . . . . . . . . . . . . . . . . . . . . . . . . . . 323<br />
N2601477 . . . . . . . . . . . . . . . . . . . . . . . . . . 322<br />
N2601503 . . . . . . . . . . . . . . . . . . . . . . . . . . 321<br />
N2601579 . . . . . . . . . . . . . . . . . . . . . . . . . . 317<br />
N2601580 . . . . . . . . . . . . . . . . . . . . . . . . . . 317<br />
N2601581 . . . . . . . . . . . . . . . . . . . . . . . . . . 317<br />
N2601585 . . . . . . . . . . . . . . . . . . . . . . . . . . 317<br />
N2910035 . . . . . . . . . . . . . . . . . . . . . . . . . . 321<br />
N2910342 . . . . . . . . . . . . . . . . . . . . . . . . . . 321<br />
N2910343 . . . . . . . . . . . . . . . . . . . . . . . . . . 321<br />
N2910344 . . . . . . . . . . . . . . . . . . . . . . . . . . 321<br />
Part No. Page Part No. Page Part No. Page
N2910345 – N3050411 Part Number Index<br />
Index<br />
Part Number<br />
417<br />
N2910345 . . . . . . . . . . . . . . . . . . . . . . . . . . 321<br />
N2910346 . . . . . . . . . . . . . . . . . . . . . . . . . . 321<br />
N2910349 . . . . . . . . . . . . . . . . . . . . . . . . . . 321<br />
N2910383 . . . . . . . . . . . . . . . . . . . . . . . . . . 321<br />
N2910384 . . . . . . . . . . . . . . . . . . . . . . . . . . 321<br />
N2910385 . . . . . . . . . . . . . . . . . . . . . . . . . . 321<br />
N2910511 . . . . . . . . . . . . . . . . . . . . . . 319-320<br />
N2910512 . . . . . . . . . . . . . . . . . . . . . . 319-320<br />
N2910520 . . . . . . . . . . . . . . . . . . . . . . . . . . 321<br />
N2910521 . . . . . . . . . . . . . . . . . . . . . . . . . . 321<br />
N2910522 . . . . . . . . . . . . . . . . . . . . . . . . . . 321<br />
N2910523 . . . . . . . . . . . . . . . . . . . . . . . . . . 321<br />
N2911170 . . . . . . . . . . . . . . . . . . . . . . . . . . 321<br />
N2911171 . . . . . . . . . . . . . . . . . . . . . . . . . . 321<br />
N2911172 . . . . . . . . . . . . . . . . . . . . . . . . . . 321<br />
N2911173 . . . . . . . . . . . . . . . . . . . . . . . . . . 321<br />
N2911174 . . . . . . . . . . . . . . . . . . . . . . . . . . 321<br />
N2911175 . . . . . . . . . . . . . . . . . . . . . . . . . . 321<br />
N2911176 . . . . . . . . . . . . . . . . . . . . . . . . . . 321<br />
N2911177 . . . . . . . . . . . . . . . . . . . . . . . . . . 321<br />
N2911178 . . . . . . . . . . . . . . . . . . . . . . . . . . 321<br />
N2915102 . . . . . . . . . . . . . . . . . . . . . . . . . . 321<br />
N2920117 . . . . . . . . . . . . . . . . . . . . . . . . . . 316<br />
N2920124 . . . . . . . . . . . . . . . . . . . . . . . . . . 316<br />
N2920125 . . . . . . . . . . . . . . . . . . . . . . . . . . 316<br />
N2920146 . . . . . . . . . . . . . . . . . . . . . . . . . . 316<br />
N2920149 . . . . . . . . . . . . . . . . . . . . . . . . . . 316<br />
N2922006 . . . . . . . . . . . . . . . . . . . . . . . . . . 315<br />
N2922010 . . . . . . . . . . . . . . . . . . . . . . . . . . 314<br />
N2922011 . . . . . . . . . . . . . . . . . . . . . . . . . . 314<br />
N2922028 . . . . . . . . . . . . . . . . . . . . . . . . . . 314<br />
N2922029 . . . . . . . . . . . . . . . . . . . . . . . . . . 314<br />
N2922030 . . . . . . . . . . . . . . . . . . . . . . . . . . 314<br />
N2922046 . . . . . . . . . . . . . . . . . . . . . . . . . . 314<br />
N2922082 . . . . . . . . . . . . . . . . . . . . . . . . . . 315<br />
N2930023 . . . . . . . . . . . . . . . . . . . . . . . . . . 273<br />
N2930024 . . . . . . . . . . . . . . . . . . . . . . . . . . 273<br />
N2930035 . . . . . . . . . . . . . . . . . . . . . . 208, 270<br />
N2930036 . . . . . . . . . . . . . . . . . . . . . . 208, 270<br />
N2930037 . . . . . . . . . . . . . . . . . . . . . . . . . . 270<br />
N2930038 . . . . . . . . . . . . . . . . . . . . . . . . . . 270<br />
N2930040 . . . . . . . . . . . . . . . . . . . . . . . . . . 270<br />
N2930041 . . . . . . . . . . . . . . . . . . . . . . . . . . 270<br />
N2930042 . . . . . . . . . . . . . . . . . . . . . . . . . . 270<br />
N2930043 . . . . . . . . . . . . . . . . . . . . . . . . . . 270<br />
N2930044 . . . . . . . . . . . . . . . . . . . . . . . . . . 270<br />
N2930146 . . . . . . . . . . . . . . . . . . . . . . . . . . 270<br />
N2930147 . . . . . . . . . . . . . . . . . . . . . . . . . . 270<br />
N2930311 . . . . . . . . . . . . . . . . . . . . . . . . . . 273<br />
N2930312 . . . . . . . . . . . . . . . . . . . . . . . . . . 273<br />
N2930313 . . . . . . . . . . . . . . . . . . . . . . . . . . 273<br />
N2930314 . . . . . . . . . . . . . . . . . . . . . . . . . . 270<br />
N2930340 . . . . . . . . . . . . . . . . . . . . . . . . . . 273<br />
N2930341 . . . . . . . . . . . . . . . . . . . . . . . . . . 273<br />
N2930343 . . . . . . . . . . . . . . . . . . . . . . . . . . 331<br />
N2931012 . . . . . . . . . . . . . . . . . . . . . . . . . . 273<br />
N2931054 . . . . . . . . . . . . . . . . . . . . . . . . . . 325<br />
N2931064 . . . . . . . . . . . . . . . . . . . . . . . . . . 273<br />
N2931081 . . . . . . . . . . . . . . . . . . . . . . . . . . 273<br />
N2931097 . . . . . . . . . . . . . . . . . . . . . . . . . . 270<br />
N3050102 . . . . . . . . . . . . . . . . . . . . . . . . . . . 41<br />
N3050103 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />
N3050105 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />
N3050107 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />
N3050108 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />
N3050109 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />
N3050110 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />
N3050111 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />
N3050114 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />
N3050115 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />
N3050118 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />
N3050119 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />
N3050121 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />
N3050122 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />
N3050123 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />
N3050124 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />
N3050126 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />
N3050128 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />
N3050129 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />
N3050130 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />
N3050133 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />
N3050134 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />
N3050135 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />
N3050137 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />
N3050138 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />
N3050139 . . . . . . . . . . . . . . . . . . . . . . . . . . . 41<br />
N3050141 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />
N3050142 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />
N3050144 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />
N3050145 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />
N3050146 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />
N3050148 . . . . . . . . . . . . . . . . . . . . . . . . . . . 41<br />
N3050149 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />
N3050150 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />
N3050152 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />
N3050155 . . . . . . . . . . . . . . . . . . . . . . . . . . . 41<br />
N3050157 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />
N3050158 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />
N3050161 . . . . . . . . . . . . . . . . . . . . . . . . . . . 41<br />
N3050162 . . . . . . . . . . . . . . . . . . . . . . . . . . . 41<br />
N3050165 . . . . . . . . . . . . . . . . . . . . . . . . . . . 41<br />
N3050166 . . . . . . . . . . . . . . . . . . . . . . . . . . . 41<br />
N3050168 . . . . . . . . . . . . . . . . . . . . . . . . . . . 41<br />
N3050170 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />
N3050171 . . . . . . . . . . . . . . . . . . . . . . . . . . . 41<br />
N3050172 . . . . . . . . . . . . . . . . . . . . . . . . . . . 41<br />
N3050173 . . . . . . . . . . . . . . . . . . . . . . . . . . . 41<br />
N3050174 . . . . . . . . . . . . . . . . . . . . . . . . . . . 41<br />
N3050175 . . . . . . . . . . . . . . . . . . . . . . . . . . . 41<br />
N3050176 . . . . . . . . . . . . . . . . . . . . . . . . . . . 41<br />
N3050177 . . . . . . . . . . . . . . . . . . . . . . . . . . . 41<br />
N3050178 . . . . . . . . . . . . . . . . . . . . . . . . . . . 41<br />
N3050180 . . . . . . . . . . . . . . . . . . . . . . . . . . . 41<br />
N3050182 . . . . . . . . . . . . . . . . . . . . . . . . . . . 41<br />
N3050183 . . . . . . . . . . . . . . . . . . . . . . . . . . . 41<br />
N3050184 . . . . . . . . . . . . . . . . . . . . . . . . . . . 41<br />
N3050186 . . . . . . . . . . . . . . . . . . . . . . . . . . . 41<br />
N3050187 . . . . . . . . . . . . . . . . . . . . . . . . . . . 41<br />
N3050189 . . . . . . . . . . . . . . . . . . . . . . . . . . . 41<br />
N3050190 . . . . . . . . . . . . . . . . . . . . . . . . . . . 41<br />
N3050191 . . . . . . . . . . . . . . . . . . . . . . . . . . . 41<br />
N3050192 . . . . . . . . . . . . . . . . . . . . . . . . . . . 41<br />
N3050196 . . . . . . . . . . . . . . . . . . . . . . . . . . . 44<br />
N3050197 . . . . . . . . . . . . . . . . . . . . . . . . . . . 44<br />
N3050198 . . . . . . . . . . . . . . . . . . . . . . . . . . . 44<br />
N3050201 . . . . . . . . . . . . . . . . . . . . . . . . . . . 42<br />
N3050202 . . . . . . . . . . . . . . . . . . . . . . . . . . . 42<br />
N3050203 . . . . . . . . . . . . . . . . . . . . . . . . . . . 42<br />
N3050204 . . . . . . . . . . . . . . . . . . . . . . . . . . . 42<br />
N3050205 . . . . . . . . . . . . . . . . . . . . . . . . . . . 42<br />
N3050206 . . . . . . . . . . . . . . . . . . . . . . . . . . . 42<br />
N3050207 . . . . . . . . . . . . . . . . . . . . . . . . . . . 42<br />
N3050208 . . . . . . . . . . . . . . . . . . . . . . . . . . . 42<br />
N3050209 . . . . . . . . . . . . . . . . . . . . . . . . . . . 42<br />
N3050210 . . . . . . . . . . . . . . . . . . . . . . . . . . . 42<br />
N3050211 . . . . . . . . . . . . . . . . . . . . . . . . . . . 42<br />
N3050212 . . . . . . . . . . . . . . . . . . . . . . . . . . . 42<br />
N3050213 . . . . . . . . . . . . . . . . . . . . . . . . . . . 42<br />
N3050214 . . . . . . . . . . . . . . . . . . . . . . . . . . . 42<br />
N3050215 . . . . . . . . . . . . . . . . . . . . . . . . . . . 42<br />
N3050216 . . . . . . . . . . . . . . . . . . . . . . . . . . . 42<br />
N3050217 . . . . . . . . . . . . . . . . . . . . . . . . . . . 42<br />
N3050218 . . . . . . . . . . . . . . . . . . . . . . . . . . . 42<br />
N3050302 . . . . . . . . . . . . . . . . . . . . . . . . . . . 41<br />
N3050303 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />
N3050305 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />
N3050307 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />
N3050308 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />
N3050309 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />
N3050310 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />
N3050311 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />
N3050314 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />
N3050315 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />
N3050318 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />
N3050319 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />
N3050321 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />
N3050322 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />
N3050323 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />
N3050324 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />
N3050326 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />
N3050328 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />
N3050329 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />
N3050330 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />
N3050333 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />
N3050334 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />
N3050335 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />
N3050337 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />
N3050338 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />
N3050339 . . . . . . . . . . . . . . . . . . . . . . . . . . . 41<br />
N3050341 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />
N3050342 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />
N3050344 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />
N3050345 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />
N3050346 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />
N3050348 . . . . . . . . . . . . . . . . . . . . . . . . . . . 41<br />
N3050349 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />
N3050350 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />
N3050352 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />
N3050355 . . . . . . . . . . . . . . . . . . . . . . . . . . . 41<br />
N3050357 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />
N3050358 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />
N3050361 . . . . . . . . . . . . . . . . . . . . . . . . . . . 41<br />
N3050362 . . . . . . . . . . . . . . . . . . . . . . . . . . . 41<br />
N3050365 . . . . . . . . . . . . . . . . . . . . . . . . . . . 41<br />
N3050366 . . . . . . . . . . . . . . . . . . . . . . . . . . . 41<br />
N3050368 . . . . . . . . . . . . . . . . . . . . . . . . . . . 41<br />
N3050370 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />
N3050371 . . . . . . . . . . . . . . . . . . . . . . . . . . . 41<br />
N3050372 . . . . . . . . . . . . . . . . . . . . . . . . . . . 41<br />
N3050373 . . . . . . . . . . . . . . . . . . . . . . . . . . . 41<br />
N3050374 . . . . . . . . . . . . . . . . . . . . . . . . . . . 41<br />
N3050375 . . . . . . . . . . . . . . . . . . . . . . . . . . . 41<br />
N3050376 . . . . . . . . . . . . . . . . . . . . . . . . . . . 41<br />
N3050377 . . . . . . . . . . . . . . . . . . . . . . . . . . . 41<br />
N3050378 . . . . . . . . . . . . . . . . . . . . . . . . . . . 41<br />
N3050380 . . . . . . . . . . . . . . . . . . . . . . . . . . . 41<br />
N3050382 . . . . . . . . . . . . . . . . . . . . . . . . . . . 41<br />
N3050383 . . . . . . . . . . . . . . . . . . . . . . . . . . . 41<br />
N3050384 . . . . . . . . . . . . . . . . . . . . . . . . . . . 41<br />
N3050386 . . . . . . . . . . . . . . . . . . . . . . . . . . . 41<br />
N3050387 . . . . . . . . . . . . . . . . . . . . . . . . . . . 41<br />
N3050389 . . . . . . . . . . . . . . . . . . . . . . . . . . . 41<br />
N3050390 . . . . . . . . . . . . . . . . . . . . . . . . . . . 41<br />
N3050391 . . . . . . . . . . . . . . . . . . . . . . . . . . . 41<br />
N3050392 . . . . . . . . . . . . . . . . . . . . . . . . . . . 41<br />
N3050401 . . . . . . . . . . . . . . . . . . . . . . . . . . . 42<br />
N3050402 . . . . . . . . . . . . . . . . . . . . . . . . . . . 42<br />
N3050403 . . . . . . . . . . . . . . . . . . . . . . . . . . . 42<br />
N3050404 . . . . . . . . . . . . . . . . . . . . . . . . . . . 42<br />
N3050405 . . . . . . . . . . . . . . . . . . . . . . . . . . . 42<br />
N3050406 . . . . . . . . . . . . . . . . . . . . . . . . . . . 42<br />
N3050407 . . . . . . . . . . . . . . . . . . . . . . . . . . . 42<br />
N3050408 . . . . . . . . . . . . . . . . . . . . . . . . . . . 42<br />
N3050409 . . . . . . . . . . . . . . . . . . . . . . . . . . . 42<br />
N3050410 . . . . . . . . . . . . . . . . . . . . . . . . . . . 42<br />
N3050411 . . . . . . . . . . . . . . . . . . . . . . . . . . . 42<br />
Part No. Page Part No. Page Part No. Page<br />
See page 4 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
See page 2 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong>
Index Part Number N3050412 – N5150130<br />
Index<br />
Part Number<br />
418<br />
N3050412 . . . . . . . . . . . . . . . . . . . . . . . . . . . 42<br />
N3050413 . . . . . . . . . . . . . . . . . . . . . . . . . . . 42<br />
N3050414 . . . . . . . . . . . . . . . . . . . . . . . . . . . 42<br />
N3050415 . . . . . . . . . . . . . . . . . . . . . . . . . . . 42<br />
N3050416 . . . . . . . . . . . . . . . . . . . . . . . . . . . 42<br />
N3050417 . . . . . . . . . . . . . . . . . . . . . . . . . . . 42<br />
N3050418 . . . . . . . . . . . . . . . . . . . . . . . . . . . 42<br />
N3050605 . . . . . . . . . . . . . . . . . . . . . . . . . . . 47<br />
N3050611 . . . . . . . . . . . . . . . . . . . . . . . . . . . 47<br />
N3050615 . . . . . . . . . . . . . . . . . . . . . . . . . . . 47<br />
N3050620 . . . . . . . . . . . . . . . . . . . . . . . . . . . 47<br />
N3050630 . . . . . . . . . . . . . . . . . . . . . . . . . . . 47<br />
N3050634 . . . . . . . . . . . . . . . . . . . . . . . . . . . 47<br />
N3050655 . . . . . . . . . . . . . . . . . . . . . . . . . . . 47<br />
N3050657 . . . . . . . . . . . . . . . . . . . . . . . . . . . 47<br />
N3050664 . . . . . . . . . . . . . . . . . . . . . . . . . . . 47<br />
N3050670 . . . . . . . . . . . . . . . . . . . . . . . . . . . 47<br />
N3050672 . . . . . . . . . . . . . . . . . . . . . . . . . . . 47<br />
N3050675 . . . . . . . . . . . . . . . . . . . . . . . . . . . 47<br />
N3050680 . . . . . . . . . . . . . . . . . . . . . . . . . . . 47<br />
N3050683 . . . . . . . . . . . . . . . . . . . . . . . . . . . 47<br />
N3050691 . . . . . . . . . . . . . . . . . . . . . . . . . . . 47<br />
N3050702 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />
N3050703 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />
N3050705 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />
N3050707 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />
N3050708 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />
N3050709 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />
N3050710 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />
N3050711 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />
N3050714 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />
N3050715 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />
N3050718 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />
N3050719 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />
N3050721 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />
N3050722 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />
N3050723 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />
N3050726 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />
N3050728 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />
N3050729 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />
N3050730 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />
N3050734 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />
N3050735 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />
N3050737 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />
N3050738 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />
N3050739 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />
N3050741 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />
N3050742 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />
N3050744 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />
N3050745 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />
N3050746 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />
N3050748 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />
N3050749 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />
N3050750 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />
N3050752 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />
N3050755 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />
N3050757 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />
N3050758 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />
N3050761 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />
N3050762 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />
N3050765 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />
N3050766 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />
N3050768 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />
N3050770 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />
N3050771 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />
N3050772 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />
N3050773 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />
N3050775 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />
N3050776 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />
N3050777 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />
N3050778 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />
N3050780 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />
N3050782 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />
N3050783 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />
N3050786 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />
N3050787 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />
N3050789 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />
N3050791 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />
N3050792 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />
N3050801 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />
N3050802 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />
N3050803 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />
N3050804 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />
N3050805 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />
N3050806 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />
N3050807 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />
N3050808 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />
N3050809 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />
N3050810 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />
N3050811 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />
N3050812 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />
N3050813 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />
N3050814 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />
N3050815 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />
N3050816 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />
N3050817 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />
N3050818 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />
N3050860 . . . . . . . . . . . . . . . . . . . . . . . . . . . 47<br />
N3050861 . . . . . . . . . . . . . . . . . . . . . . . . . . . 47<br />
N3050862 . . . . . . . . . . . . . . . . . . . . . . . . . . . 47<br />
N3050863 . . . . . . . . . . . . . . . . . . . . . . . . . . . 47<br />
N3050864 . . . . . . . . . . . . . . . . . . . . . . . . . . . 47<br />
N3050865 . . . . . . . . . . . . . . . . . . . . . . . . . . . 47<br />
N3050866 . . . . . . . . . . . . . . . . . . . . . . . . . . . 47<br />
N3050867 . . . . . . . . . . . . . . . . . . . . . . . . . . . 47<br />
N3050868 . . . . . . . . . . . . . . . . . . . . . . . . . . . 47<br />
N3050869 . . . . . . . . . . . . . . . . . . . . . . . . . . . 47<br />
N3050870 . . . . . . . . . . . . . . . . . . . . . . . . . . . 47<br />
N3050871 . . . . . . . . . . . . . . . . . . . . . . . . . . . 47<br />
N3050872 . . . . . . . . . . . . . . . . . . . . . . . . . . . 47<br />
N3050873 . . . . . . . . . . . . . . . . . . . . . . . . . . . 47<br />
N3050874 . . . . . . . . . . . . . . . . . . . . . . . . . . . 47<br />
N3051050 . . . . . . . . . . . . . . . . . . . . . . . . . . . 45<br />
N3110109 . . . . . . . . . . . . . . . . . . . . . . . . 17, 20<br />
N3110110 . . . . . . . . . . . . . . . . . . . . . . . . . . . 17<br />
N3110111 . . . . . . . . . . . . . . . . . . . . . . . . . . . 17<br />
N3110145 . . . . . . . . . . . . . . . . . . . . . . . . . . . 31<br />
N3110146 . . . . . . . . . . . . . . . . . . . . . . . . . . . 32<br />
N3110147 . . . . . . . . . . . . . . . . . . . . . . . . . . . 34<br />
N3110149 . . . . . . . . . . . . . . . . . . . . . . . . . . . 32<br />
N3111158 . . . . . . . . . . . . . . . . . . . . . . . . . . . 17<br />
N3141005 . . . . . . . . . . . . . . . . . . . . . . . . . . . 60<br />
N3141009 . . . . . . . . . . . . . . . . . . . . . . . . . . . 64<br />
N3141010 . . . . . . . . . . . . . . . . . . . . . . . . . . . 64<br />
N3141011 . . . . . . . . . . . . . . . . . . . . . . . . . . . 60<br />
N3141012 . . . . . . . . . . . . . . . . . . . . . . . . . . . 60<br />
N3141014 . . . . . . . . . . . . . . . . . . . . . 57, 60, 63<br />
N3141015 . . . . . . . . . . . . . . . . . . . . . . . . 57, 60<br />
N3141016 . . . . . . . . . . . . . . . . . . . . . . . . 58, 60<br />
N3141017 . . . . . . . . . . . . . . . . . . . . . . . . . . . 60<br />
N3141018 . . . . . . . . . . . . . . . . . . . . . . . . 60, 63<br />
N3141019 . . . . . . . . . . . . . . . . . . . . . . . . 57, 60<br />
N3141020 . . . . . . . . . . . . . . . . . . . . . . . . . . . 60<br />
N3141021 . . . . . . . . . . . . . . . . . . . . . 57-58, 60<br />
N3141022 . . . . . . . . . . . . . . . . . . . . . 57-58, 60<br />
N3141023 . . . . . . . . . . . . . . . . . . . . . . . . . . . 60<br />
N3141025 . . . . . . . . . . . . . . . . . . . . . . . . . . . 61<br />
N3141026 . . . . . . . . . . . . . . . . . . . . . 61-62, 64<br />
N3141027 . . . . . . . . . . . . . . . . . . . . . . . . 61, 64<br />
N3141028 . . . . . . . . . . . . . . . . . . . . . . . . . . . 61<br />
N3141029 . . . . . . . . . . . . . . . . . . . . . . . . 61-62<br />
N3141030 . . . . . . . . . . . . . . . . . . . . . 61-62, 64<br />
N3141031 . . . . . . . . . . . . . . . . . . . . . 61-62, 64<br />
N3141032 . . . . . . . . . . . . . . . . . . . . . 61-62, 64<br />
N3142000 . . . . . . . . . . . . . . . . . . . . . . . . . . . 62<br />
N3142001 . . . . . . . . . . . . . . . . . . . . . . . . . . . 62<br />
N3142002 . . . . . . . . . . . . . . . . . . . . . . . . . . . 62<br />
N3142003 . . . . . . . . . . . . . . . . . . . . . . . . . . . 62<br />
N3142013 . . . . . . . . . . . . . . . . . . . . . . . . 60, 63<br />
N3142345 . . . . . . . . . . . . . . . . . . . . . . . . . . . 57<br />
N3142346 . . . . . . . . . . . . . . . . . . . . . . . . . . . 57<br />
N3142347 . . . . . . . . . . . . . . . . . . . . . . . . . . . 57<br />
N3142348 . . . . . . . . . . . . . . . . . . . . . . . . . . . 57<br />
N3142349 . . . . . . . . . . . . . . . . . . . . . . . . 57-58<br />
N3142350 . . . . . . . . . . . . . . . . . . . . . . . . 57-58<br />
N3142351 . . . . . . . . . . . . . . . . . . . . . . . . . . . 57<br />
N3142352 . . . . . . . . . . . . . . . . . . . . . . . . . . . 57<br />
N3142353 . . . . . . . . . . . . . . . . . . . . . . . . . . . 57<br />
N3142354 . . . . . . . . . . . . . . . . . . . . . . . . . . . 57<br />
N3142355 . . . . . . . . . . . . . . . . . . . . . . . . . . . 59<br />
N3142356 . . . . . . . . . . . . . . . . . . . . . . . . . . . 59<br />
N3142357 . . . . . . . . . . . . . . . . . . . . . . . . . . . 59<br />
N3142360 . . . . . . . . . . . . . . . . . . . . . . . . . . . 59<br />
N3142363 . . . . . . . . . . . . . . . . . . . . . . . . . . . 59<br />
N3142364 . . . . . . . . . . . . . . . . . . . . . . . . . . . 59<br />
N3142366 . . . . . . . . . . . . . . . . . . . . . . . . . . . 59<br />
N3142367 . . . . . . . . . . . . . . . . . . . . . . . . . . . 62<br />
N3142368 . . . . . . . . . . . . . . . . . . . . . . . . . . . 62<br />
N3142369 . . . . . . . . . . . . . . . . . . . . . . . . . . . 62<br />
N3142370 . . . . . . . . . . . . . . . . . . . . . . . . . . . 62<br />
N3142371 . . . . . . . . . . . . . . . . . . . . . . . . . . . 62<br />
N3142372 . . . . . . . . . . . . . . . . . . . . . . . . . . . 62<br />
N3142373 . . . . . . . . . . . . . . . . . . . . . . . . . . . 62<br />
N3142374 . . . . . . . . . . . . . . . . . . . . . . . . . . . 62<br />
N3142398 . . . . . . . . . . . . . . . . . . . . . . . . 61-62<br />
N3142399 . . . . . . . . . . . . . . . . . . . . . . . . . . . 60<br />
N3142400 . . . . . . . . . . . . . . . . . . . . . . . . . . . 60<br />
N3142409 . . . . . . . . . . . . . . . . . . . . . . . . . . . 58<br />
N3142410 . . . . . . . . . . . . . . . . . . . . . . . . . . . 58<br />
N3142411 . . . . . . . . . . . . . . . . . . . . . . . . . . . 58<br />
N3142412 . . . . . . . . . . . . . . . . . . . . . . . . . . . 58<br />
N3142413 . . . . . . . . . . . . . . . . . . . . . . . . . . . 58<br />
N3142415 . . . . . . . . . . . . . . . . . . . . . . . . . . . 58<br />
N3142416 . . . . . . . . . . . . . . . . . . . . . 58, 60, 63<br />
N3142418 . . . . . . . . . . . . . . . . . . . . . . . . . . . 60<br />
N3142419 . . . . . . . . . . . . . . . . . . . . . . . . . . . 63<br />
N3142420 . . . . . . . . . . . . . . . . . . . . . . . . . . . 63<br />
N3142423 . . . . . . . . . . . . . . . . . . . . . . . . . . . 63<br />
N3142424 . . . . . . . . . . . . . . . . . . . . . . . . . . . 63<br />
N3142425 . . . . . . . . . . . . . . . . . . . . . . . . . . . 63<br />
N3142427 . . . . . . . . . . . . . . . . . . . . . . . . . . . 63<br />
N3142428 . . . . . . . . . . . . . . . . . . . . . . . . . . . 63<br />
N3142429 . . . . . . . . . . . . . . . . . . . . . . . . . . . 63<br />
N3142430 . . . . . . . . . . . . . . . . . . . . . . . . . . . 59<br />
N3142431 . . . . . . . . . . . . . . . . . . . . . . . . . . . 59<br />
N3142435 . . . . . . . . . . . . . . . . . . . . . . . . . . . 64<br />
N3142436 . . . . . . . . . . . . . . . . . . . . . . . . . . . 63<br />
N3142437 . . . . . . . . . . . . . . . . . . . . . . . . . . . 63<br />
N3142438 . . . . . . . . . . . . . . . . . . . . . . . . . . . 64<br />
N3142449 . . . . . . . . . . . . . . . . . . . . . . . . . . . 64<br />
N3142450 . . . . . . . . . . . . . . . . . . . . . . . . . . . 64<br />
N3142451 . . . . . . . . . . . . . . . . . . . . . . . . . . . 64<br />
N3142452 . . . . . . . . . . . . . . . . . . . . . . . . . . . 60<br />
N3142453 . . . . . . . . . . . . . . . . . . . . . . . . . . . 64<br />
N3142454 . . . . . . . . . . . . . . . . . . . . . . . . . . . 64<br />
N3142456 . . . . . . . . . . . . . . . . . . . . . . . . . . . 60<br />
N3142485 . . . . . . . . . . . . . . . . . . . . . . . . . . . 59<br />
N3142486 . . . . . . . . . . . . . . . . . . . . . . . . . . . 59<br />
N3150131 . . . . . . . . . . . . . . . . . . . . . . . . . . . 48<br />
N3150188 . . . . . . . . . . . . . . . . . . . . . . . . 17, 19<br />
N3150303 . . . . . . . . . . . . . . . . . . . . . . . . . . . 48<br />
N5001409 . . . . . . . . . . . . . . . . . . . . . . . . . . . 77<br />
N5150060 . . . . . . . . . . . . . . . . . . . . . . . . . . 174<br />
N5150100 . . . . . . . . . . . . . . . . . . . . . . . . . . 178<br />
N5150103 . . . . . . . . . . . . . . . . . . . . . . . . . . 178<br />
N5150130 . . . . . . . . . . . . . . . . . . . . . . . . . . 332<br />
Part No. Page Part No. Page Part No. Page
N5150160 – N5370490 Part Number Index<br />
Index<br />
Part Number<br />
419<br />
N5150160 . . . . . . . . . . . . . . . . . . . . . . . . . . 176<br />
N5150162 . . . . . . . . . . . . . . . . . . . . . . . . . . 330<br />
N5150165 . . . . . . . . . . . . . . . . . . . . . . . . . . 176<br />
N5150166 . . . . . . . . . . . . . . . . . . . . . . . . . . 176<br />
N5150167 . . . . . . . . . . . . . . . . . . . . . . . . . . 330<br />
N5150181 . . . . . . . . . . . . . . . . . . . . . . 176, 330<br />
N5150183 . . . . . . . . . . . . . . . . . . . . . . . . . . 332<br />
N5150187 . . . . . . . . . . . . . . . . . . . . . . . . . . 332<br />
N5150262 . . . . . . . . . . . . . . . . . . . . . . . . . . 330<br />
N5150267 . . . . . . . . . . . . . . . . . . . . . . . . . . 330<br />
N5150349 . . . . . . . . . . . . . . . . . . . . . . 178, 332<br />
N5150512 . . . . . . . . . . . . . . . . . . . . . . 178, 332<br />
N5150518 . . . . . . . . . . . . . . . . . . . . . . 178, 332<br />
N5150715 . . . . . . . . . . . . . . . . . . . . . . 178, 332<br />
N5156021 . . . . . . . . . . . . . . . . . . . . . . 178, 332<br />
N5156025 . . . . . . . . . . . . . . . . . . . . . . 178, 332<br />
N5190172 . . . . . . . . . . . . . . . . . . . . . . . . . . 369<br />
N5190180 . . . . . . . . . . . . . . . . . . . . . . . . . . 343<br />
N5190196 . . . . . . . . . . . . . . . . . . . . . . . . . . 369<br />
N5190197 . . . . . . . . . . . . . . . . . . . . . . . . . . 369<br />
N5190202 . . . . . . . . . . . . . . . . . . . . . . . . . . 369<br />
N5190203 . . . . . . . . . . . . . . . . . . . . . . . . . . 369<br />
N5190226 . . . . . . . . . . . . . . . . . . . . . . . . . . 348<br />
N5190264 . . . . . . . . . . . . . . . . . . . . . . . . . . 369<br />
N5190269 . . . . . . . . . . . . . . . . . . . . . . . . . . 355<br />
N5190270 . . . . . . . . . . . . . . . . . . . . . . . . . . 355<br />
N5190271 . . . . . . . . . . . . . . . . . . . . . . . . . . 355<br />
N5190276 . . . . . . . . . . . . . . . . . . . . . . . . . . 371<br />
N5190279 . . . . . . . . . . . . . . . . . . . . . . . . . . 371<br />
N5190280 . . . . . . . . . . . . . . . . . . . . . . . . . . 372<br />
N5190282 . . . . . . . . . . . . . . . . . . . . . . . . . . 369<br />
N5190283 . . . . . . . . . . . . . . . . . . . . . . . . . . 372<br />
N5190284 . . . . . . . . . . . . . . . . . . . . . . . . . . 369<br />
N5190285 . . . . . . . . . . . . . . . . . . . . . . . . . . 371<br />
N5190330 . . . . . . . . . . . . . . . . . . . . . . . . . . 371<br />
N5190370 . . . . . . . . . . . . . . . . . . . . . . . . . . 366<br />
N5190376 . . . . . . . . . . . . . . . . . . . . . . 361, 365<br />
N5190377 . . . . . . . . . . . . . . . . . . . . . . 357, 365<br />
N5190378 . . . . . . . . . . . . . . . . . . . . . . 361, 365<br />
N5190393 . . . . . . . . . . . . . . . . . . . . . . 357, 364<br />
N5190399 . . . . . . . . . . . . . . . . . . . . . . . . . . 364<br />
N5190416 . . . . . . . . . . . . . . . . . . . . . . . . . . 365<br />
N5190417 . . . . . . . . . . . . . . . . . . . . . . . . . . 366<br />
N5190462 . . . . . . . . . . . . . . . . . . . . . . . . . . 354<br />
N5190504 . . . . . . . . . . . . . . . . . . . . . . . . . . 348<br />
N5190510 . . . . . . . . . . . . . . . . . . . . . . . . . . 369<br />
N5190511 . . . . . . . . . . . . . . . . . . . . . . . . . . 369<br />
N5190512 . . . . . . . . . . . . . . . . . . . . . . . . . . 370<br />
N5190515 . . . . . . . . . . . . . . . . . . . . . . . . . . 371<br />
N5190516 . . . . . . . . . . . . . . . . . . . . . . . . . . 371<br />
N5190606 . . . . . . . . . . . . . . . . . . . . . . . . . . 361<br />
N5190609 . . . . . . . . . . . . . . . . . . . . . . 363, 365<br />
N5190611 . . . . . . . . . . . . . . . . . . . . . . 363, 365<br />
N5190613 . . . . . . . . . . . . . . . . . . . . . . . . . . 366<br />
N5190614 . . . . . . . . . . . . . . . . . . . . . . . . . . 357<br />
N5190615 . . . . . . . . . . . . . . . . . . . . . . 363, 365<br />
N5190616 . . . . . . . . . . . . . . . . . . . . . . . . . . 368<br />
N5190617 . . . . . . . . . . . . . . . . . . . . . . . . . . 366<br />
N5190619 . . . . . . . . . . . . . . . . . . . . . . . . . . 365<br />
N5190738 . . . . . . . . . . . . . . . . . . . . . . . . . . 348<br />
N5190762 . . . . . . . . . . . . . . . . . . . . . . . . . . 350<br />
N5190763 . . . . . . . . . . . . . . . . . . . . . . . . . . 364<br />
N5190784 . . . . . . . . . . . . . . . . . . . . . . . . . . 348<br />
N5190786 . . . . . . . . . . . . . . . . . . . . . . . . . . 369<br />
N5190788 . . . . . . . . . . . . . . . . . . . . . . 346, 372<br />
N5190869 . . . . . . . . . . . . . . . . . . . . . . . . . . 368<br />
N5191009 . . . . . . . . . . . . . . . . . . . . . . . . . . 348<br />
N5191085 . . . . . . . . . . . . . . . . . . . . . . . . . . 351<br />
N5191333 . . . . . . . . . . . . . . . . . . . . . . . . . . 351<br />
N5191469 . . . . . . . . . . . . . . . . . . . . . . . . . . 366<br />
N5191472 . . . . . . . . . . . . . . . . . . . . . . . . . . 357<br />
N5191549 . . . . . . . . . . . . . . . . . . 357, 361, 365<br />
N5191552 . . . . . . . . . . . . . . . . . . . . . . . . . . 370<br />
N5191662 . . . . . . . . . . . . . . . . . . . . . . . . . . 356<br />
N5191700 . . . . . . . . . . . . . . . . . . . . . . 363, 365<br />
N5191792 . . . . . . . . . . . . . . . . . . . . . . . . . . 366<br />
N5191837 . . . . . . . . . . . . . . . . . . . . . . . . . . 361<br />
N5191845 . . . . . . . . . . . . . . . . . . . . . . 348, 351<br />
N5191875 . . . . . . . . . . . . . . . . . . . . . . 353, 369<br />
N5192094 . . . . . . . . . . . . . . . . . . . . . . . . . . 364<br />
N5200001 . . . . . . . . . . . . . . . . . . . . . . . . . . 346<br />
N5200032 . . . . . . . . . . . . . . . . . . . . . . . . . . 348<br />
N5200033 . . . . . . . . . . . . . . . . . . . . . . . . . . 348<br />
N5200040 . . . . . . . . . . . . . . . . . . . . . . . . . . 372<br />
N5201016 . . . . . . . . . . . . . . . . . . . . . . . . . . 346<br />
N5202019 . . . . . . . . . . . . . . . . . . . . . . . . . . 355<br />
N5203020 . . . . . . . . . . . . . . . . . . . . . . 369, 372<br />
N5350110 . . . . . . . . . . . . . . . . . . . . . . . . . . 348<br />
N5350130 . . . . . . . . . . . . . . . . . . . . . . . . . . 347<br />
N5350131 . . . . . . . . . . . . . . . . . . . . . . . . . . 347<br />
N5350201 . . . . . . . . . . . . . . . . . . . . . . . . . . 367<br />
N5350202 . . . . . . . . . . . . . . . . . . . . . . 355, 367<br />
N5350203 . . . . . . . . . . . . . . . . . . . . . . . . . . 367<br />
N5350204 . . . . . . . . . . . . . . . . . . . . . . . . . . 367<br />
N5350302 . . . . . . . . . . . . . . . . . . . . . . . . . . 348<br />
N5351002 . . . . . . . . . . . . . . . . . . . . . . . . . . 348<br />
N5351009 . . . . . . . . . . . . . . . . . . . . . . . . . . 348<br />
N5352004 . . . . . . . . . . . . . . . . . . . . . . . . . . 367<br />
N5352005 . . . . . . . . . . . . . . . . . . . . . . . . . . 367<br />
N5352006 . . . . . . . . . . . . . . . . . . . . . . . . . . 367<br />
N5352027 . . . . . . . . . . . . . . . . . . . . . . . . . . 367<br />
N5353009 . . . . . . . . . . . . . . . . . . . . . . . . . . 364<br />
N5353013 . . . . . . . . . . . . . . . . . . . . . . . . . . 365<br />
N5353021 . . . . . . . . . . . . . . . . . . . . . . . . . . 365<br />
N5353023 . . . . . . . . . . . . . . . . . . . . . . . . . . 364<br />
N5353030 . . . . . . . . . . . . . . . . . . . . . . . . . . 363<br />
N5353031 . . . . . . . . . . . . . . . . . . . . . . . . . . 363<br />
N5353032 . . . . . . . . . . . . . . . . . . . . . . . . . . 359<br />
N5353035 . . . . . . . . . . . . . . . . . . . . . . . . . . 356<br />
N5353036 . . . . . . . . . . . . . . . . . . . . . . . . . . 365<br />
N5353037 . . . . . . . . . . . . . . . . . . . . . . . . . . 365<br />
N5353038 . . . . . . . . . . . . . . . . . . . . . . . . . . 365<br />
N5353039 . . . . . . . . . . . . . . . . . . . . . . . . . . 365<br />
N5353040 . . . . . . . . . . . . . . . . . . . . . . . . . . 365<br />
N5353041 . . . . . . . . . . . . . . . . . . . . . . . . . . 365<br />
N5353042 . . . . . . . . . . . . . . . . . . . . . . . . . . 365<br />
N5353043 . . . . . . . . . . . . . . . . . . . . . . . . . . 365<br />
N5353044 . . . . . . . . . . . . . . . . . . . . . . . . . . 365<br />
N5353045 . . . . . . . . . . . . . . . . . . . . . . . . . . 365<br />
N5353046 . . . . . . . . . . . . . . . . . . . . . . . . . . 365<br />
N5353047 . . . . . . . . . . . . . . . . . . . . . . . . . . 365<br />
N5353048 . . . . . . . . . . . . . . . . . . . . . . . . . . 364<br />
N5353050 . . . . . . . . . . . . . . . . . . . . . . . . . . 365<br />
N5353051 . . . . . . . . . . . . . . . . . . . . . . . . . . 365<br />
N5353052 . . . . . . . . . . . . . . . . . . . . . . . . . . 365<br />
N5353054 . . . . . . . . . . . . . . . . . . . . . . . . . . 365<br />
N5353056 . . . . . . . . . . . . . . . . . . . . . . . . . . 365<br />
N5353057 . . . . . . . . . . . . . . . . . . . . . . . . . . 365<br />
N5353059 . . . . . . . . . . . . . . . . . . . . . . . . . . 365<br />
N5353060 . . . . . . . . . . . . . . . . . . . . . . . . . . 366<br />
N5353061 . . . . . . . . . . . . . . . . . . . . . . . . . . 366<br />
N5353062 . . . . . . . . . . . . . . . . . . . . . . . . . . 366<br />
N5353063 . . . . . . . . . . . . . . . . . . . . . . . . . . 366<br />
N5353065 . . . . . . . . . . . . . . . . . . . . . . . . . . 366<br />
N5353073 . . . . . . . . . . . . . . . . . . . . . . . . . . 366<br />
N5353074 . . . . . . . . . . . . . . . . . . . . . . . . . . 366<br />
N5353075 . . . . . . . . . . . . . . . . . . . . . . . . . . 366<br />
N5353076 . . . . . . . . . . . . . . . . . . . . . . . . . . 366<br />
N5353077 . . . . . . . . . . . . . . . . . . . . . . . . . . 366<br />
N5353078 . . . . . . . . . . . . . . . . . . . . . . . . . . 362<br />
N5353079 . . . . . . . . . . . . . . . . . . . . . . . . . . 358<br />
N5353081 . . . . . . . . . . . . . . . . . . . . . . . . . . 358<br />
N5353082 . . . . . . . . . . . . . . . . . . . . . . . . . . 358<br />
N5353083 . . . . . . . . . . . . . . . . . . . . . . . . . . 358<br />
N5353084 . . . . . . . . . . . . . . . . . . . . . . . . . . 358<br />
N5353085 . . . . . . . . . . . . . . . . . . . . . . . . . . 362<br />
N5353086 . . . . . . . . . . . . . . . . . . . . . . . . . . 362<br />
N5353087 . . . . . . . . . . . . . . . . . . 358-359, 362<br />
N5353095 . . . . . . . . . . . . . . . . . . . . . . . . . . 364<br />
N5353114 . . . . . . . . . . . . . . . . . . . . . . . . . . 366<br />
N5353115 . . . . . . . . . . . . . . . . . . . . . . . . . . 366<br />
N5353116 . . . . . . . . . . . . . . . . . . . . . . . . . . 366<br />
N5353117 . . . . . . . . . . . . . . . . . . . . . . . . . . 366<br />
N5353118 . . . . . . . . . . . . . . . . . . . . . . . . . . 366<br />
N5353140 . . . . . . . . . . . . . . . . . . . . . . . . . . 366<br />
N5353141 . . . . . . . . . . . . . . . . . . . . . . . . . . 366<br />
N5353144 . . . . . . . . . . . . . . . . . . . . . . . . . . 366<br />
N5356000 . . . . . . . . . . . . . . . . . . . . . . . . . . 354<br />
N5356001 . . . . . . . . . . . . . . . . . . . . . . . . . . 354<br />
N5356002 . . . . . . . . . . . . . . . . . . . . . . 340-341<br />
N5356003 . . . . . . . . . . . . . . . . . . . . . . . . . . 340<br />
N5356004 . . . . . . . . . . . . . . . . . . . . . . . . . . 340<br />
N5356005 . . . . . . . . . . . . . . . . . . . . . . . . . . 340<br />
N5356006 . . . . . . . . . . . . . . . . . . . . . . . . . . 340<br />
N5356007 . . . . . . . . . . . . . . . . . . . . . . . . . . 340<br />
N5356008 . . . . . . . . . . . . . . . . . . . . . . . . . . 339<br />
N5356009 . . . . . . . . . . . . . . . . . . . . . . . . . . 339<br />
N5356010 . . . . . . . . . . . . . . . . . . . . . . 338, 342<br />
N5356012 . . . . . . . . . . . . . . . . . . 338, 342, 367<br />
N5356016 . . . . . . . . . . . . . . . . . . . . . . 343, 367<br />
N5356017 . . . . . . . . . . . . . . . . . . . . . . 343, 367<br />
N5356018 . . . . . . . . . . . . . . . . . . . . . . . . . . 367<br />
N5356019 . . . . . . . . . . . . . . . . . . . . . . 343, 367<br />
N5356020 . . . . . . . . . . . . . . . . . . 341, 343, 367<br />
N5356021 . . . . . . . . . . . . . . . . . . . . . . 342, 367<br />
N5356022 . . . . . . . . . . . . . . . . . . . . . . . . . . 367<br />
N5356023 . . . . . . . . . . . . . . . . . . . . . . . . . . 367<br />
N5356025 . . . . . . . . . . . . . . . . . . . . . . 341, 367<br />
N5356026 . . . . . . . . . . . . . . . . . . . . . . 341, 367<br />
N5356027 . . . . . . . . . . . . . . . . . . . . . . . . . . 344<br />
N5356028 . . . . . . . . . . . . . . . . . . . . . . . . . . 344<br />
N5356029 . . . . . . . . . . . . . . . . . . . . . . . . . . 365<br />
N5356030 . . . . . . . . . . . . . . . . . . . . . . . . . . 344<br />
N5356031 . . . . . . . . . . . . . . . . . . . . . . . . . . 344<br />
N5356032 . . . . . . . . . . . . . . . . . . . . . . . . . . 344<br />
N5356033 . . . . . . . . . . . . . . . . . . . . . . . . . . 344<br />
N5356034 . . . . . . . . . . . . . . . . . . 341-342, 367<br />
N5356035 . . . . . . . . . . . . . . . . . . . . . . . . . . 344<br />
N5356036 . . . . . . . . . . . . . . . . . . . . . . . . . . 344<br />
N5360016 . . . . . . . . . . . . . . . . . . . . . . . . . . 349<br />
N5360142 . . . . . . . . . . . . . . . . . . . . . . . . . . 350<br />
N5360188 . . . . . . . . . . . . . . . . . . . . . . . . . . 346<br />
N5360236 . . . . . . . . . . . . . . . . . . . . . . . . . . 351<br />
N5360321 . . . . . . . . . . . . . . . . . . . . . . . . . . 346<br />
N5361078 . . . . . . . . . . . . . . . . . . . . . . . . . . 351<br />
N5361180 . . . . . . . . . . . . . . . . . . . . . . . . . . 351<br />
N5365044 . . . . . . . . . . . . . . . . . . . . . . . . . . 349<br />
N5370103 . . . . . . . . . . . . . . . . . . . . . . . . . . 354<br />
N5370142 . . . . . . . . . . . . . . . . . . . . . . . . . . 348<br />
N5370147 . . . . . . . . . . . . . . . . . . . . . . . . . . 347<br />
N5370153 . . . . . . . . . . . . . . . . . . . . . . . . . . 350<br />
N5370205 . . . . . . . . . . . . . . . . . . . . . . . . . . 347<br />
N5370206 . . . . . . . . . . . . . . . . . . . . . . . . . . 347<br />
N5370207 . . . . . . . . . . . . . . . . . . . . . . . . . . 347<br />
N5370208 . . . . . . . . . . . . . . . . . . . . . . . . . . 347<br />
N5370236 . . . . . . . . . . . . . . . . . . . . . . . . . . 351<br />
N5370298 . . . . . . . . . . . . . . . . . . . . . . . . . . 346<br />
N5370299 . . . . . . . . . . . . . . . . . . . . . . . . . . 346<br />
N5370331 . . . . . . . . . . . . . . . . . . . . . . . . . . 369<br />
N5370332 . . . . . . . . . . . . . . . . . . . . . . . . . . 369<br />
N5370459 . . . . . . . . . . . . . . . . . . . . . . . . . . 369<br />
N5370464 . . . . . . . . . . . . . . . . . . . . . . . . . . 372<br />
N5370478 . . . . . . . . . . . . . . . . . . . . . . . . . . 369<br />
N5370487 . . . . . . . . . . . . . . . . . . . . . . . . . . 371<br />
N5370488 . . . . . . . . . . . . . . . . . . . . . . . . . . 371<br />
N5370490 . . . . . . . . . . . . . . . . . . . . . . . . . . 371<br />
Part No. Page Part No. Page Part No. Page<br />
See page 4 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
See page 2 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong>
Index Part Number N5370540 – N6120009<br />
Index<br />
Part Number<br />
420<br />
N5370540 . . . . . . . . . . . . . . . . . . . . . . . . . . 347<br />
N5370550 . . . . . . . . . . . . . . . . . . . . . . . . . . 372<br />
N5370552 . . . . . . . . . . . . . . . . . . . . . . . . . . 370<br />
N5370553 . . . . . . . . . . . . . . . . . . . . . . . . . . 370<br />
N5370554 . . . . . . . . . . . . . . . . . . . . . . . . . . 370<br />
N5370555 . . . . . . . . . . . . . . . . . . . . . . . . . . 370<br />
N5370600 . . . . . . . . . . . . . . . . . . . . . . . . . . 374<br />
N5370603 . . . . . . . . . . . . . . . . . . . . . . . . . . 374<br />
N5370606 . . . . . . . . . . . . . . . . . . . . . . . . . . 374<br />
N5370610 . . . . . . . . . . . . . . . . . . . . . . . . . . 374<br />
N5370611 . . . . . . . . . . . . . . . . . . . . . . . . . . 374<br />
N5370619 . . . . . . . . . . . . . . . . . . . . . . . . . . 374<br />
N5370620 . . . . . . . . . . . . . . . . . . . . . . . . . . 374<br />
N5370622 . . . . . . . . . . . . . . . . . . . . . . . . . . 374<br />
N5370623 . . . . . . . . . . . . . . . . . . . . . . . . . . 374<br />
N5370637 . . . . . . . . . . . . . . . . . . . . . . . . . . 373<br />
N5370638 . . . . . . . . . . . . . . . . . . . . . . . . . . 373<br />
N5370647 . . . . . . . . . . . . . . . . . . . . . . . . . . 373<br />
N5370648 . . . . . . . . . . . . . . . . . . . . . . . . . . 373<br />
N5370665 . . . . . . . . . . . . . . . . . . . . . . . . . . 373<br />
N5370666 . . . . . . . . . . . . . . . . . . . . . . . . . . 373<br />
N5370667 . . . . . . . . . . . . . . . . . . . . . . . . . . 373<br />
N5370668 . . . . . . . . . . . . . . . . . . . . . . . . . . 373<br />
N5370669 . . . . . . . . . . . . . . . . . . . . . . . . . . 373<br />
N5370671 . . . . . . . . . . . . . . . . . . . . . . . . . . 374<br />
N5370672 . . . . . . . . . . . . . . . . . . . . . . . . . . 374<br />
N5370673 . . . . . . . . . . . . . . . . . . . . . . . . . . 374<br />
N5370674 . . . . . . . . . . . . . . . . . . . . . . . . . . 374<br />
N5370675 . . . . . . . . . . . . . . . . . . . . . . . . . . 374<br />
N5370676 . . . . . . . . . . . . . . . . . . . . . . . . . . 374<br />
N5370679 . . . . . . . . . . . . . . . . . . . . . . . . . . 373<br />
N5372060 . . . . . . . . . . . . . . . . . . . . . . . . . . 347<br />
N5372187 . . . . . . . . . . . . . . . . . . . . . . . . . . 347<br />
N5373009 . . . . . . . . . . . . . . . . . . . . . . . . . . 347<br />
N5373126 . . . . . . . . . . . . . . . . . . . . . . . . . . 351<br />
N5374098 . . . . . . . . . . . . . . . . . . . . . . . . . . 347<br />
N5374099 . . . . . . . . . . . . . . . . . . . . . . . . . . 347<br />
N5376097 . . . . . . . . . . . . . . . . . . . . . . . . . . 345<br />
N5376806 . . . . . . . . . . . . . . . . . . . . . . . . . . 369<br />
N5376817 . . . . . . . . . . . . . . . . . . . . . . . . . . 369<br />
N5380015 . . . . . . . . . . . . . . . . . . . . . . . . . . 353<br />
N5380037 . . . . . . . . . . . . . . . . . . . . . . . . . . 353<br />
N5380051 . . . . . . . . . . . . . . . . . . . . . . . . . . 353<br />
N5380052 . . . . . . . . . . . . . . . . . . . . . . . . . . 353<br />
N5380053 . . . . . . . . . . . . . . . . . . . . . . . . . . 353<br />
N5380057 . . . . . . . . . . . . . . . . . . . . . . 353, 367<br />
N5380058 . . . . . . . . . . . . . . . . . . . . . . 353, 367<br />
N5380062 . . . . . . . . . . . . . . . . . . . . . . . . . . 353<br />
N5380063 . . . . . . . . . . . . . . . . . . . . . . . . . . 353<br />
N5380071 . . . . . . . . . . . . . . . . . . . . . . 353, 367<br />
N5381081 . . . . . . . . . . . . . . . . . . . . . . . . . . 353<br />
N5390101 . . . . . . . . . . . . . . . . . . . . . . . . . . 356<br />
N5390102 . . . . . . . . . . . . . . . . . . . . . . . . . . 356<br />
N5390105 . . . . . . . . . . . . . . . . . . 356, 358, 360<br />
N5390107 . . . . . . . . . . . . . . . . . . 356, 360, 362<br />
N5390122 . . . . . . . . . . . . . . . . . . . . . . . . . . 356<br />
N5390128 . . . . . . . . . . . . . . . . . . . . . . . . . . 366<br />
N5390131 . . . . . . . . . . . . . . . . . . . . . . . . . . 358<br />
N5390132 . . . . . . . . . . . . . . . . . . . . . . . . . . 362<br />
N5390133 . . . . . . . . . . . . . . . . . . . . . . . . . . 360<br />
N5390134 . . . . . . . . . . . . . . . . . . . . . . . . . . 363<br />
N5390135 . . . . . . . . . . . . . . . . . . . . . . . . . . 361<br />
N5390136 . . . . . . . . . . . . . . . . . . . . . . . . . . 357<br />
N5390137 . . . . . . . . . . . . . . . . . . . . . . . . . . 357<br />
N5390138 . . . . . . . . . . . . . . . . . . . . . . . . . . 361<br />
N5390141 . . . . . . . . . . . . . . . . . . . . . . . . . . 366<br />
N5390143 . . . . . . . . . . . . . . . . . . . . . . . . . . 360<br />
N5390144 . . . . . . . . . . . . . . . . . . . . . . . . . . 360<br />
N5390145 . . . . . . . . . . . . . . . . . . . . . . . . . . 360<br />
N5390146 . . . . . . . . . . . . . . . . . . . . . . . . . . 360<br />
N5390154 . . . . . . . . . . . . . . . . . . . . . . . . . . 362<br />
N5390156 . . . . . . . . . . . . . . . . . . . . . . . . . . 362<br />
N5390157 . . . . . . . . . . . . . . . . . . . . . . . . . . 363<br />
N5390174 . . . . . . . . . . . . . . . . . . . . . . . . . . 358<br />
N5390175 . . . . . . . . . . . . . . . . . . . . . . 356, 358<br />
N5390176 . . . . . . . . . . . . . . . . . . . . . . . . . . 358<br />
N5390177 . . . . . . . . . . . . . . . . . . . . . . . . . . 362<br />
N5390178 . . . . . . . . . . . . . . . . . . . . . . . . . . 362<br />
N5390193 . . . . . . . . . . . . . . . . . . . . . . . . . . 362<br />
N5390197 . . . . . . . . . . . . . . . . . . . . . . . . . . 356<br />
N5390420 . . . . . . . . . . . . . . . . . . . . . . . . . . 356<br />
N5390426 . . . . . . . . . . . . . . . . . . . . . . . . . . 356<br />
N5390427 . . . . . . . . . . . . . . . . . . . . . . . . . . 356<br />
N5390428 . . . . . . . . . . . . . . . . . . . . . . . . . . 356<br />
N5390451 . . . . . . . . . . . . . . . . . . . . . . . . . . 356<br />
N5390452 . . . . . . . . . . . . . . . . . . . . . . . . . . 356<br />
N5390453 . . . . . . . . . . . . . . . . . . . . . . . . . . 356<br />
N5390460 . . . . . . . . . . . . . . . . . . . . . . . . . . 361<br />
N5390461 . . . . . . . . . . . . . . . . . . . . . . . . . . 361<br />
N5390462 . . . . . . . . . . . . . . . . . . . . . . . . . . 361<br />
N5390463 . . . . . . . . . . . . . . . . . . . . . . . . . . 361<br />
N5390464 . . . . . . . . . . . . . . . . . . . . . . . . . . 359<br />
N5390465 . . . . . . . . . . . . . . . . . . . . . . . . . . 359<br />
N5390466 . . . . . . . . . . . . . . . . . . . . . . . . . . 359<br />
N5390467 . . . . . . . . . . . . . . . . . . . . . . . . . . 359<br />
N5390468 . . . . . . . . . . . . . . . . . . . . . . . . . . 359<br />
N5390469 . . . . . . . . . . . . . . . . . . . . . . . . . . 359<br />
N5390470 . . . . . . . . . . . . . . . . . . . . . . . . . . 359<br />
N5390471 . . . . . . . . . . . . . . . . . . . . . . . . . . 359<br />
N5390472 . . . . . . . . . . . . . . . . . . . . . . . . . . 359<br />
N5390478 . . . . . . . . . . . . . . . . . . . . . . . . . . 356<br />
N5391014 . . . . . . . . . . . . . . . . . . . . . . . . . . 360<br />
N5391015 . . . . . . . . . . . . . . . . . . . . . . . . . . 360<br />
N5391016 . . . . . . . . . . . . . . . . . . . . . . . . . . 356<br />
N5391017 . . . . . . . . . . . . . . . . . . . . . . . . . . 356<br />
N5391048 . . . . . . . . . . . . . . . . . . . . . . . . . . 366<br />
N5391051 . . . . . . . . . . . . . . . . . . . . . . . . . . 366<br />
N5391054 . . . . . . . . . . . . . . . . . . . . . . . . . . 356<br />
N5391063 . . . . . . . . . . . . . . . . . . . . . . . . . . 356<br />
N5391085 . . . . . . . . . . . . . . . . . . . . . . . . . . 366<br />
N5391090 . . . . . . . . . . . . . . . . . . . . . . . . . . 366<br />
N5391093 . . . . . . . . . . . . . . . . . . . . . . . . . . 357<br />
N5391094 . . . . . . . . . . . . . . . . . . . . . . . . . . 357<br />
N5391095 . . . . . . . . . . . . . . . . . . . . . . . . . . 357<br />
N5391104 . . . . . . . . . . . . . . . . . . . . . . . . . . 366<br />
N5391181 . . . . . . . . . . . . . . . . . . 357, 364-365<br />
N5391183 . . . . . . . . . . . . . . . . . . . . . . . . . . 357<br />
N5391184 . . . . . . . . . . . . . . . . . . . . . . . . . . 366<br />
N6000637 . . . . . . . . . . . . . . . . . . . . . . . . . . 135<br />
N6000968 . . . . . . . . . . . . . . . . . . . . . . . . . . 131<br />
N6000981 . . . . . . . . . . . . . . . . . . . . . . . . . . 135<br />
N6001204 . . . . . . . . . . . . . . . . . . . . . . 132-133<br />
N6003057 . . . . . . . . . . . . . . . . . . . . . . . . . . 135<br />
N6003066 . . . . . . . . . . . . . . . . . . . . . . . . . . 135<br />
N6100016 . . . . . . . . . . . . . . . . . . . . . . . . . . 134<br />
N6100037 . . . . . . . . . . . . . . . . . . . . . . . . . . 133<br />
N6100038 . . . . . . . . . . . . . . . . . . . . . . 133, 139<br />
N6100047 . . . . . . . . . . . . . . . . . . . . . . . . . . 150<br />
N6100048 . . . . . . . . . . . . . . . . . . . . . . . . . . 152<br />
N6100102 . . . . . . . . . . . . . . . . . . 134, 150, 153<br />
N6100153 . . . . . . . . . . . . . . 150, 152, 154-155<br />
N6100157 . . . . . . . . . . . . . . . . . . . . . . . . . . 150<br />
N6100158 . . . . . . . . . . . . . . . . . . . . . . . . . . 150<br />
N6100159 . . . . . . . . . . . . . . . . . . . . . . 150, 155<br />
N6100161 . . . . . . . . . . . . . . . . . . . . . . . . . . 131<br />
N6100170 . . . . . . . . . . . . . . . . . . . . . . . . . . 133<br />
N6100194 . . . . . . . . . . . . . . . . . . . . . . 132, 134<br />
N6100228 . . . . . . . . . . . . . . . . . . . . . . . . . . 139<br />
N6100243 . . . . . . . . . . . . . . . . . . . . . . . . . . 135<br />
N6100244 . . . . . . . . . . . . . . . . . . . . . . . . . . 135<br />
N6100245 . . . . . . . . . . . . . . . . . . . . . . . . . . 135<br />
N6100253 . . . . . . . . . . . . . . . . . . . . . . . . . . 139<br />
N6100256 . . . . . . . . . . . . . . . . . . . . . . . . . . 154<br />
N6100260 . . . . . . . . . . . . . . . . . . . . . . . . . . 155<br />
N6100261 . . . . . . . . . . . . . . . . . . . . . . . . . . 155<br />
N6100264 . . . . . . . . . . . . . . . . . . . . . . . . . . 135<br />
N6100275 . . . . . . . . . . . . . . . . . . . . . . 150, 155<br />
N6100289 . . . . . . . . . . . . . . . . . . . . . . . . . . 134<br />
N6100331 . . . . . . . . . . . . . . . . . . . . . . 150, 155<br />
N6100342 . . . . . . . . . . . . . . . . . . . . . . . . . . 156<br />
N6100357 . . . . . . . . . . . . . . . . . . . . . . . . . . 132<br />
N6100361 . . . . . . . . . . . . . . . . . . . . . . . . . . 132<br />
N6100364 . . . . . . . . . . . . . . . . . . . . . . . . . . 132<br />
N6100410 . . . . . . . . . . . . . . . . . . 147, 177, 183<br />
N6100411 . . . . . . . . . . . . . . . . . . . . . . . . . . 177<br />
N6100430 . . . . . . . . . . . . . . . . . . . . . . . . . . 132<br />
N6101034 . . . . . . . . . . . . . . . . . . . . . . 150, 155<br />
N6101037 . . . . . . . . . . . . . . . . . . . . . . . . . . 133<br />
N6101048 . . . . . . . . . . . . . . . . . . . . . . . . . . 152<br />
N6101050 . . . . . . . . . . . . . . . . . . . . . . . . . . 152<br />
N6101052 . . . . . . . . . . . . . . . . . . . . . . 150, 157<br />
N6101070 . . . . . . . . . . . . . . . . . . . . . . . . . . . 93<br />
N6101085 . . . . . . . . . . . . . . . . . . . . . . 132-133<br />
N6101100 . . . . . . . . . . . . . . . . . . . . . . . . . . 133<br />
N6101182 . . . . . . . . . . . . . . . . . . . . . . . . . . . 88<br />
N6101183 . . . . . . . . . . . . . . . . . . . . . . . . . . . 88<br />
N6101251 . . . . . . . . . . . . . . . . . . . . . . . 88, 161<br />
N6101252 . . . . . . . . . . . . . . . . . . . . . . . 88, 161<br />
N6101253 . . . . . . . . . . . . . . . . . . . . . . . 88, 161<br />
N6101276 . . . . . . . . . . . . . . . . . . . . . . . . . . . 89<br />
N6101297 . . . . . . . . . . . . . . . . . . . . . . . . . . 132<br />
N6101345 . . . . . . . . . . . . . . . . . . . . . . . . . . 134<br />
N6101358 . . . . . . . . . . . . . . . . . . . . . . . . . . 150<br />
N6101372 . . . . . . . . . . . . . . . . . . . . . . 150, 157<br />
N6101374 . . . . . . . . . . . . . . . . . . . . . . . . . . 150<br />
N6101375 . . . . . . . . . . . . . . . . . . . . . . . 92, 158<br />
N6101377 . . . . . . . . . . . . . . . . . . . . . . . 92, 166<br />
N6101378 . . . . . . . . . . . . . . . . . . . . . . . . . . 150<br />
N6101380 . . . . . . . . . . . . . . . . . . . . . . . 88, 161<br />
N6101390 . . . . . . . . . . . . . . . . . . . . . . . 88, 161<br />
N6101412 . . . . . . . . . . . . . . . . . . . . . . . . . . 134<br />
N6101469 . . . . . . . . . . . . . . . . . . . . . . . 88, 161<br />
N6101470 . . . . . . . . . . . . . . . . . . . . . . . 88, 161<br />
N6101473 . . . . . . . . . . . . . . . . . . . . . . . . . . 166<br />
N6101474 . . . . . . . . . . . . . . . . . . . . . . . . . . 183<br />
N6101482 . . . . . . . . . . . . . . . . . . . . . . 150, 155<br />
N6101539 . . . . . . . . . . . . . . . . . . . . . . 155, 158<br />
N6101547 . . . . . . . . . . . . . . . . . . . . . . . . . . 133<br />
N6101696 . . . . . . . . . . . . . . . . . . . . . . . . . . 140<br />
N6101702 . . . . . . . . . . . . . . . . . . . . . . . . . . 154<br />
N6101703 . . . . . . . . . . . . . . . . . . . . . . 154, 158<br />
N6101715 . . . . . . . . . . . . . . . . . . . . . . . . . . 155<br />
N6101747 . . . . . . . . . . . . . . . . . . . . . . . . . . 155<br />
N6101751 . . . . . . . . . . . . . . . . . . . . . . . . . . 155<br />
N6101760 . . . . . . . . . . . . . . . . . . . . . . . 88, 161<br />
N6102190 . . . . . . . . . . . . . . . . . . . . . . . . . . . 92<br />
N6102197 . . . . . . . . . . . . . . . . . . . . . . . . . . 180<br />
N6102351 . . . . . . . . . . . . . . . . . . . . . . . . . . 180<br />
N6102354 . . . . . . . . . . . . . . 132, 134, 150, 153<br />
N6103079 . . . . . . . . . . . . . . . . . . . . . . . . . . 156<br />
N6103080 . . . . . . . . . . . . . . . . . . . . . . . . . . 156<br />
N6103082 . . . . . . . . . . . . . . . . . . . . . . . . . . 156<br />
N6103089 . . . . . . . . . . . . . . . . . . . . . . . . . . 132<br />
N6103151 . . . . . . . . . . . . . . . . . . . . . . . . . . 132<br />
N6103167 . . . . . . . . . . . . . . . . . . . . . . . . . . 132<br />
N6103175 . . . . . . . . . . . . . . . . . . . . . . . . . . 132<br />
N6103188 . . . . . . . . . . . . . . . . . . . . . . . . . . 132<br />
N6103196 . . . . . . . . . . . . . . . . . . . . . . . . . . 156<br />
N6103225 . . . . . . . . . . . . . . . . . . . . . . . . . . 132<br />
N6120001 . . . . . . . . . . . . . . . . . . . . . . . 92, 153<br />
N6120004 . . . . . . . . . . . . . . . . . . . . . . . . . . 166<br />
N6120005 . . . . . . . . . . . . . . . . . . . . . . . . . . 166<br />
N6120006 . . . . . . . . . . . . . . . . . . . . . . 132, 141<br />
N6120007 . . . . . . . . . . . . . . . . . . . . . . . . . . 152<br />
N6120008 . . . . . . . . . . . . . . . . . . . . . . . . . . 152<br />
N6120009 . . . . . . . . . . . . . . . . . . . . . . . . . . 151<br />
Part No. Page Part No. Page Part No. Page
N6120010 – N8122126 Part Number Index<br />
Index<br />
Part Number<br />
421<br />
N6120010 . . . . . . . . . . . . . . . . . . . . . . . . . . 133<br />
N6120011 . . . . . . . . . . . . . . . . . . . . . . . . . . 131<br />
N6120012 . . . . . . . . . . . . . . . . . . . . . . . . . . 141<br />
N6120014 . . . . . . . . . . . . . . . . . . . . . . . . . . 131<br />
N6120015 . . . . . . . . . . . . . . . . . . . . . . . . . . 141<br />
N6120016 . . . . . . . . . . . . . . . . . . . . . . . . . . 160<br />
N6120017 . . . . . . . . . . . . . . . . . . . . . . . . . . 160<br />
N6120020 . . . . . . . . . . . . . . . . . . . 92, 132, 141<br />
N6120022 . . . . . . . . . . . . . . . . . . . . . . . . . . 151<br />
N6120023 . . . . . . . . . . . . . . . . . . . . . . . . . . 152<br />
N6120024 . . . . . . . . . . . . . . . . . . . . . . . . . . 133<br />
N6120025 . . . . . . . . . . . . . . . . . . . . . . . . . . 152<br />
N6120026 . . . . . . . . . . . . . . . . . . . . . . . . . . 131<br />
N6120027 . . . . . . . . . . . . . . . . . . . . . . . . . . 141<br />
N6120031 . . . . . . . . . . . . . . . . . . . . . . . . . . . 88<br />
N6120032 . . . . . . . . . . . . . . . . . . . . . . . . . . 171<br />
N6120033 . . . . . . . . . . . . . . . . . . . . . . . . . . 171<br />
N6120036 . . . . . . . . . . . . . . . . . . . . . . . . . . . 88<br />
N6120047 . . . . . . . . . . . . . . . . . . . . . . . . . . 140<br />
N6120050 . . . . . . . . . . . . . . . . . . . . . . . . . . 151<br />
N6120057 . . . . . . . . . . . . . . . . . . . . . . . . . . 140<br />
N6120059 . . . . . . . . . . . . . . . . . . 131-132, 140<br />
N6120061 . . . . . . . . . . . . . . . . . . . . . . . . . . 140<br />
N6120062 . . . . . . . . . . . . . . . . . . . . . . . . . . 140<br />
N6120070 . . . . . . . . . . . . . . . . . . . . . . . . . . 134<br />
N6120071 . . . . . . . . . . . . . . . . . . . . . . . . . . 152<br />
N6120072 . . . . . . . . . . . . . . . . . . . . . . . . . . 152<br />
N6120074 . . . . . . . . . . . . . . . . . . . . . . . . . . 155<br />
N6120075 . . . . . . . . . . . . . . . . . . . . . . . . . . 155<br />
N6120076 . . . . . . . . . . . . . . . . . . . . . . . . . . 154<br />
N6120077 . . . . . . . . . . . . . . . . . . . . . . . . . . 154<br />
N6120078 . . . . . . . . . . . . . . . . . . . . . . . . . . 160<br />
N6120080 . . . . . . . . . . . . . . . . . . . . . . . . . . 141<br />
N6120082 . . . . . . . . . . . . . . . . . . . . . . . . . . 154<br />
N6120083 . . . . . . . . . . . . . . . . . . . . . . . . . . 154<br />
N6120088 . . . . . . . . . . . . . . . . . . . . . . . . . . 135<br />
N6120089 . . . . . . . . . . . . . . . . . . . . . . . . . . 135<br />
N6120090 . . . . . . . . . . . . . . . . . . . . . . . . . . 139<br />
N6120091 . . . . . . . . . . . . . . . . . . . . . . . . . . 139<br />
N6120092 . . . . . . . . . . . . . . . . . . . . . . . . . . 139<br />
N6120093 . . . . . . . . . . . . . . . . . . . . . . . . . . 139<br />
N6120094 . . . . . . . . . . . . . . . . . . . . . . . . . . 139<br />
N6120095 . . . . . . . . . . . . . . . . . . . . . . . . . . 135<br />
N6120098 . . . . . . . . . . . . . . . . . . . . . . . . . . 154<br />
N6120100 . . . . . . . . . . . . . . . . . . . . . . . . . . 152<br />
N6120101 . . . . . . . . . . . . . . . . . . . . . . . . . . 151<br />
N6120102 . . . . . . . . . . . . . . . . . . . . . . . . . . 155<br />
N6120105 . . . . . . . . . . . . . . . . . . . . . . . . . . . 88<br />
N6120120 . . . . . . . . . . . . . . . . . . . . . . . . . . 133<br />
N6120121 . . . . . . . . . . . . . . . . . . . . . . . . . . 133<br />
N6120122 . . . . . . . . . . . . . . . . . . . . . . . . . . 131<br />
N6120123 . . . . . . . . . . . . . . . . . . . . . . . . . . 131<br />
N6120124 . . . . . . . . . . . . . . . . . . . . . . . . . . 141<br />
N6120125 . . . . . . . . . . . . . . . . . . . . . . . . . . 141<br />
N6120126 . . . . . . . . . . . . . . . . . . . . . . . . . . 139<br />
N6120127 . . . . . . . . . . . . . . . . . . . . . . . . . . 139<br />
N6120128 . . . . . . . . . . . . . . . . . . . . . . . . . . 135<br />
N6120129 . . . . . . . . . . . . . . . . . . . . . . . . . . 135<br />
N6120130 . . . . . . . . . . . . . . . . . . . . . . . . . . 140<br />
N6120131 . . . . . . . . . . . . . . . . . . . . . . . . . . 140<br />
N6120136 . . . . . . . . . . . . . . . . . . . . . . . . . . 152<br />
N6120137 . . . . . . . . . . . . . . . . . . . . . . . . . . 152<br />
N6120138 . . . . . . . . . . . . . . . . . . . . . . . . . . 151<br />
N6120139 . . . . . . . . . . . . . . . . . . . . . . . . . . 151<br />
N6120140 . . . . . . . . . . . . . . . . . . . . . . . . . . 155<br />
N6120141 . . . . . . . . . . . . . . . . . . . . . . . . . . 155<br />
N6120142 . . . . . . . . . . . . . . . . . . . . . . . . . . 154<br />
N6120143 . . . . . . . . . . . . . . . . . . . . . . . . . . 154<br />
N6120144 . . . . . . . . . . . . . . . . . . . . . . . . . . 156<br />
N6120146 . . . . . . . . . . . . . . . . . . . . . . . . . . 166<br />
N6120148 . . . . . . . . . . . . . . . . . . . . . . . . . . 166<br />
N6120149 . . . . . . . . . . . . . . . . . . . . . . . . . . 166<br />
N6120150 . . . . . . . . . . . . . . . . . . . . . . . . . . 141<br />
N6120152 . . . . . . . . . . . . . . . . . . . . . . . . . . 166<br />
N6120153 . . . . . . . . . . . . . . . . . . . . . . . . . . 166<br />
N6120154 . . . . . . . . . . . . . . . . . . . . . . . . . . 166<br />
N6120155 . . . . . . . . . . . . . . . . . . . . . . . . . . 166<br />
N6120156 . . . . . . . . . . . . . . . . . . . . . . . . . . 166<br />
N6120157 . . . . . . . . . . . . . . . . . . . . . . . . . . 166<br />
N6120158 . . . . . . . . . . . . . . . . . . . . . . . . . . 160<br />
N6120159 . . . . . . . . . . . . . . . . . . . . . . . . . . 160<br />
N6120161 . . . . . . . . . . . . . . . . . . . . . . 132, 134<br />
N6120162 . . . . . . . . . . . . . . . . . . . . . . 132-133<br />
N6120163 . . . . . . . . . . . . . . . . . . . . . . . . . . 156<br />
N6120165 . . . . . . . . . . . . . . . . . . . . . . . . . . 132<br />
N6120166 . . . . . . . . . . . . . . . . . . . . . . . . . . 132<br />
N6120167 . . . . . . . . . . . . . . . . . . . . . . . . . . 132<br />
N6120168 . . . . . . . . . . . . . . . . . . . . . . . . . . 132<br />
N6120179 . . . . . . . . . . . . . . . . . . . . . . 138, 156<br />
N6120181 . . . . . . . . . . . . . . . . . . . . . . . . . . . 88<br />
N6121000 . . . . . . . . . . . . . . . . . . . . . . . . . . 152<br />
N6121001 . . . . . . . . . . . . . . . . . . . . . . 150, 157<br />
N6121002 . . . . . . . . . . . . . . . . . . . . . . 150, 157<br />
N6121003 . . . . . . . . . . . . . . . . . . . . . . . 92, 158<br />
N6121004 . . . . . . . . . . . . . . . . . . . . . . 155, 158<br />
N6121006 . . . . . . . . . . . . . . . . . . . . . . 155, 158<br />
N6121020 . . . . . . . . . . . . . . . . . . . . . . 150, 157<br />
N6121021 . . . . . . . . . . . . . . . . . . . . . . 150, 157<br />
N6121022 . . . . . . . . . . . . . . . . . . 150, 157-158<br />
N6200119 . . . . . . . . . . . . . . . . . . . . . . . . . . 181<br />
N6200150 . . . . . . . . . . . . . . . . . . 144, 182, 184<br />
N6200200 . . . . . . . . . . . . . . . . . . . . . . . . . . 145<br />
N6200210 . . . . . . . . . . . . . . . . . . . . . . . . . . 183<br />
N6201001 . . . . . . . . . . . . . . . . . . . . . . . . . . 146<br />
N6201030 . . . . . . . . . . . . . . . . . . . . . . . . . . 146<br />
N6212407 . . . . . . . . . . . . . . . . . . . . . . . . . . 137<br />
N6300063 . . . . . . . . . . . . . . . . . . . . . . . . . . 180<br />
N6300155 . . . . . . . . . . . . . . . . . . . . . . . . . . 180<br />
N6301054 . . . . . . . . . . . . . . . . . . . . . . . . . . 183<br />
N6301107 . . . . . . . . . . . . . . . . . . . . . . . . . . 180<br />
N6301108 . . . . . . . . . . . . . . . . . . . . . . . . . . 180<br />
N6470012 . . . . . . . . . . . . . . . . . . . . . . . . . . 137<br />
N6470045 . . . . . . . . . . . . . . . . . . . . . . . . . . 137<br />
N6470070 . . . . . . . . . . . . . . . . . . . . . . . . . . 138<br />
N6470080 . . . . . . . . . . . . . . . . . . . . . . . . . . 138<br />
N6470207 . . . . . . . . . . . . . . . . . . . . . . . . . . 137<br />
N6471025 . . . . . . . . . . . . . . . . . . . . . . 137, 163<br />
N6471031 . . . . . . . . . . . . . . . . . . . . . . . . . . 137<br />
N6500123 . . . . . . . . . . . . . . . . . . . . . . . . . . 164<br />
N6500133 . . . . . . . . . . . . . . . . . . . . . . . . . . 177<br />
N6502000 . . . . . . . . . . . . . . . . . . . . . . . . . . 158<br />
N6502001 . . . . . . . . . . . . . . . . . . . . . . 157-158<br />
N6502002 . . . . . . . . . . . . . . . . . . . . . . . . . . 158<br />
N6502003 . . . . . . . . . . . . . . . . . . . . . . . . . . 157<br />
N6502004 . . . . . . . . . . . . . . . . . . . . . . . . . . 157<br />
N6502005 . . . . . . . . . . . . . . . . . . . . . . . . . . 157<br />
N6502006 . . . . . . . . . . . . . . . . . . . . . . . . . . 157<br />
N6502009 . . . . . . . . . . . . . . . . . . . . . . . . . . 157<br />
N6502010 . . . . . . . . . . . . . . . . . . . . . . . . . . 157<br />
N6502011 . . . . . . . . . . . . . . . . . . . . . . . . . . 157<br />
N6502012 . . . . . . . . . . . . . . . . . . . . . . . . . . 157<br />
N6502013 . . . . . . . . . . . . . . . . . . . . . . . . . . 158<br />
N6502014 . . . . . . . . . . . . . . . . . . . . . . . . . . 158<br />
N6502015 . . . . . . . . . . . . . . . . . . . . . . . . . . 158<br />
N6502016 . . . . . . . . . . . . . . . . . . . . . . . . . . 158<br />
N6502017 . . . . . . . . . . . . . . . . . . . . . . . . . . 158<br />
N6513010 . . . . . . . . . . . . . . . . . . . . . . . . . . 174<br />
N6513020 . . . . . . . . . . . . . . . . . . . . . . . . . . 174<br />
N6513040 . . . . . . . . . . . . . . . . . . . . . . . . . . 175<br />
N6513060 . . . . . . . . . . . . . . . . . . . . . . . . . . 174<br />
N6513070 . . . . . . . . . . . . . . . . . . . . . . . . . . 174<br />
N6520010 . . . . . . . . . . . . . . . . . . . . . . . . . . 152<br />
N6520011 . . . . . . . . . . . . . . . . . . . . . . . . . . 152<br />
N6520012 . . . . . . . . . . . . . . . . . . . . . . . . . . 151<br />
N6520013 . . . . . . . . . . . . . . . . . . . . . . . . . . 151<br />
N6520014 . . . . . . . . . . . . . . . . . . . . . . . . . . 155<br />
N6520015 . . . . . . . . . . . . . . . . . . . . . . . . . . 155<br />
N6520016 . . . . . . . . . . . . . . . . . . . . . . . . . . 152<br />
N6520017 . . . . . . . . . . . . . . . . . . . . . . . . . . 152<br />
N6520018 . . . . . . . . . . . . . . . . . . . . . . . . . . 132<br />
N6520019 . . . . . . . . . . . . . . . . . . . . . . . . . . 132<br />
N6520020 . . . . . . . . . . . . . . . . . . . . . . . . . . 131<br />
N6520021 . . . . . . . . . . . . . . . . . . . . . . . . . . 131<br />
N6520022 . . . . . . . . . . . . . . . . . . . . . . . . . . 141<br />
N6520023 . . . . . . . . . . . . . . . . . . . . . . . . . . 141<br />
N6520024 . . . . . . . . . . . . . . . . . . . . . . . . . . 139<br />
N6520025 . . . . . . . . . . . . . . . . . . . . . . . . . . 139<br />
N6520026 . . . . . . . . . . . . . . . . . . . . . . . . . . 140<br />
N6520027 . . . . . . . . . . . . . . . . . . . . . . . . . . 140<br />
N6520028 . . . . . . . . . . . . . . . . . . . . . . . . . . 135<br />
N6520029 . . . . . . . . . . . . . . . . . . . . . . . . . . 135<br />
N6520206 . . . . . . . . . . . . . . . . . . . . . . . . . . 138<br />
N6520220 . . . . . . . . . . . . . . . . . . . . . . . . . . 138<br />
N6520235 . . . . . . . . . . . . . . . . . . . . . . . . . . 175<br />
N6520240 . . . . . . . . . . . . . . . . . . . . . . . . . . 138<br />
N6609060 . . . . . . . . . . . . . . . . . . . . . . . . . . 180<br />
N6620065 . . . . . . . . . . . . . . . . . . . . . . . . . . 149<br />
N6621006 . . . . . . . . . . . . . . . . . . . 90, 149, 272<br />
N6621008 . . . . . . . . . . . . . . . . . . . 90, 149, 272<br />
N6621009 . . . . . . . . . . . . . . . . . . . 90, 149, 272<br />
N6621028 . . . . . . . . . . 150, 152, 154-155, 159<br />
N6700113 . . . . . . . . . . . . . . . . . . . . . . . . . . 147<br />
N6700130 . . . . . . . . . . . . . . . . . . . . . . . . . . 147<br />
N6700200 . . . . . . . . . . . . . . . . . . . . . . . . . . 145<br />
N8102011 . . . . . . . . . . . . . . . . . . . . . . . . . . 196<br />
N8120100 . . . . . . . . . . . . . . . . . . . . . . 193, 195<br />
N8120113 . . . . . . . . . . . . . . . . . . . . . . . . . . 189<br />
N8120116 . . . . . . . . . . . . . . . . . . . . . . 193, 195<br />
N8120119 . . . . . . . . . . . . . . . . . . . . . . . . . . 188<br />
N8120124 . . . . . . . . . . . . . . . . . . . . . . 201, 204<br />
N8120140 . . . . . . . . . . . . . . . . . . . . . . 199, 221<br />
N8120141 . . . . . . . . . . . . . . . . . . . . . . 199, 221<br />
N8120150 . . . . . . . . . . . . . . . . . . . . . . . . . . 203<br />
N8120161 . . . . . . . . . . . . . . . . . . . . . . . . . . 191<br />
N8120180 . . . . . . . . . . . . . . . . . . . . . . . . . . 202<br />
N8120181 . . . . . . . . . . . . . . . . . . . . . . . . . . 202<br />
N8120191 . . . . . . . . . . . . . . . . . . . . . . . . . . 207<br />
N8120192 . . . . . . . . . . . . . . . . . . . . . . . . . . 207<br />
N8120503 . . . . . . . . . . . . . . . . . . . . . . . . . . 191<br />
N8120509 . . . . . . . . . . . . . . . . . . . . . . . . . . 193<br />
N8120511 . . . . . . . . . . . . . . . . . . . . . . 189, 193<br />
N8120512 . . . . . . . . . . . . . . . . . . . . . . 189, 193<br />
N8120515 . . . . . . . . . . . . . . . . . . 193, 197-198<br />
N8120516 . . . . . . . . . . . . . . . . . . . . . . 197, 201<br />
N8120522 . . . . . . . . . . . . . . . . . . . . . . . . . . 210<br />
N8120532 . . . . . . . . . . . . . . . . . . . . . . . . . . 208<br />
N8120534 . . . . . . . . . . . . . . . . . . . . . . . . . . 208<br />
N8120541 . . . . . . . . . . . . . . . . . . . . . . . . . . 210<br />
N8120542 . . . . . . . . . . . . . . . . . . . . . . . . . . 193<br />
N8122000 . . . . . . . . . . . . . . . . . . . . . . . . . . 189<br />
N8122002 . . . . . . . . . . . . . . . . . . . . . . . . . . 189<br />
N8122003 . . . . . . . . . . . . . . . . . . . . . . . . . . 189<br />
N8122004 . . . . . . . . . . . . . . . . . . . . . . . . . . 192<br />
N8122006 . . . . . . . . . . . . . . . . . . . . . . 193, 205<br />
N8122007 . . . . . . . . . . . . . . . . . . . . . . 195, 201<br />
N8122010 . . . . . . . . . . . . . . . . . . . . . . . . . . 193<br />
N8122012 . . . . . . . . . . . . . . . . . . . . . . 193, 199<br />
N8122014 . . . . . . . . . . . . . . . . . . . . . . . . . . 211<br />
N8122017 . . . . . . . . . . . . . . . . . . . . . . . . . . 210<br />
N8122025 . . . . . . . . . . . . . . . . . . . . . . . . . . 189<br />
N8122035 . . . . . . . . . . . . . . . . . . . . . . . . . . 189<br />
N8122038 . . . . . . . . . . . . . . . . . . . . . . 210, 212<br />
N8122040 . . . . . . . . . . . . . . . . . . . . . . . . . . 189<br />
N8122114 . . . . . . . . . . . . . . . . . . . . . . . . . . 189<br />
N8122118 . . . . . . . . . . . . . . . . . . . . . . . . . . 200<br />
N8122126 . . . . . . . . . . . . . . . . . . . . . . 199, 224<br />
Part No. Page Part No. Page Part No. Page<br />
See page 4 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
See page 2 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong>
Index Part Number N8122127 – N9300232<br />
Index<br />
Part Number<br />
422<br />
N8122127 . . . . . . . . . . . . . . . . . . . . . . . . . . 199<br />
N8122132 . . . . . . . . . . . . . . . . . . . . . . . . . . 200<br />
N8122150 . . . . . . . . . . . . . . . . . . . . . . 199, 221<br />
N8122161 . . . . . . . . . . . . . . . . . . . . . . 199, 221<br />
N8122162 . . . . . . . . . . . . . . . . . . . . . . 199, 221<br />
N8122170 . . . . . . . . . . . . . . . . . . . . . . . . . . 188<br />
N8122188 . . . . . . . . . . . . . . . . . . . . . . 203, 225<br />
N8122192 . . . . . . . . . . . . . . . . . . . . . . . . . . 196<br />
N8122193 . . . . . . . . . . . . . . . . . . . . . . . . . . 190<br />
N8122194 . . . . . . . . . . . . . . . . . . . . . . . . . . 190<br />
N8122239 . . . . . . . . . . . . . . . . . . . . . . 198, 223<br />
N8122247 . . . . . . . . . . . . . . . . . . . . . . . . . . 189<br />
N8122248 . . . . . . . . . . . . . . . . . . . . . . . . . . 189<br />
N8122249 . . . . . . . . . . . . . . . . . . . . . . . . . . 208<br />
N8122250 . . . . . . . . . . . . . . . . . . . . . . . . . . 208<br />
N8122251 . . . . . . . . . . . . . . . . . . . . . . . . . . 208<br />
N8122252 . . . . . . . . . . . . . . . . . . . . . . . . . . 199<br />
N8122254 . . . . . . . . . . . . . . . . . . . . . . . . . . 208<br />
N8122256 . . . . . . . . . . . . . . . . . . . . . . . . . . 208<br />
N8122258 . . . . . . . . . . . . . . . . . . . . . . . . . . 208<br />
N8122308 . . . . . . . . . . . . . . . . . . . . . . 192-193<br />
N8122340 . . . . . . . . . . . . . . . . . . . . . . . . . . 198<br />
N8122341 . . . . . . . . . . . . . . . . . . . . . . . . . . 198<br />
N8122350 . . . . . . . . . . . . . . . . . . . . . . . . . . 196<br />
N8122351 . . . . . . . . . . . . . . . . . . . . . . . . . . 196<br />
N8122355 . . . . . . . . . . . . . . . . . . . . . . . . . . 188<br />
N8122356 . . . . . . . . . . . . . . . . . . . . . . . . . . 204<br />
N8122357 . . . . . . . . . . . . . . . . . . . . . . 197, 204<br />
N8122358 . . . . . . . . . . . . . . . . . . . . . . . . . . 194<br />
N8122359 . . . . . . . . . . . . . . . . . . . . . . . . . . 194<br />
N8122360 . . . . . . . . . . . . . . . . . . . . . . . . . . 188<br />
N8122361 . . . . . . . . . . . . . . . . . . . . . . . . . . 188<br />
N8122362 . . . . . . . . . . . . . . . . . . . . . . . . . . 200<br />
N8122363 . . . . . . . . . . . . . . . . . . . . . . . . . . 200<br />
N8122383 . . . . . . . . . . . . . . . . . . . . . . . . . . 196<br />
N8122384 . . . . . . . . . . . . . . . . . . . . . . . . . . 196<br />
N8122385 . . . . . . . . . . . . . . . . . . . . . . . . . . 192<br />
N8122387 . . . . . . . . . . . . . . . . . . . . . . . . . . 192<br />
N8122388 . . . . . . . . . . . . . . . . . . . . . . . . . . 192<br />
N8122389 . . . . . . . . . . . . . . . . . . . . . . . . . . 200<br />
N8122394 . . . . . . . . . . . . . . . . . . . . . . . . . . 194<br />
N8122410 . . . . . . . . . . . . . . . . . . . . . . . . . . 200<br />
N8122411 . . . . . . . . . . . . . . . . . . . . . . . . . . 194<br />
N8122412 . . . . . . . . . . . . . . . . . . . . . . . . . . 194<br />
N8122413 . . . . . . . . . . . . . . . . . . . . . . . . . . 194<br />
N8122414 . . . . . . . . . . . . . . . . . . . . . . . . . . 200<br />
N8122415 . . . . . . . . . . . . . . . . . . . . . . . . . . 200<br />
N8125001 . . . . . . . . . . . . . . . . . . . . . . 190, 193<br />
N8125003 . . . . . . . . . . . . . . . . . . . . . . . . . . 199<br />
N8125006 . . . . . . . . . . . . . . . . . . . . . . . . . . 193<br />
N8125029 . . . . . . . . . . . . . . . . . . . . . . . . . . 195<br />
N8125030 . . . . . . . . . . . . . . . . . . . . . . . . . . 210<br />
N8125031 . . . . . . . . . . . . . . . . . . . . . . . . . . 210<br />
N8125032 . . . . . . . . . . . . . . . . . . . . . . . . . . 210<br />
N8125033 . . . . . . . . . . . . . . . . . . . . . . 210, 212<br />
N8125034 . . . . . . . . . . . . . . . . . . . . . . . . . . 210<br />
N8125035 . . . . . . . . . . . . . . . . . . . . . . . . . . 210<br />
N8125037 . . . . . . . . . . . . . . . . . . . . . . 210, 212<br />
N8125038 . . . . . . . . . . . . . . . . . . . . . . 210, 212<br />
N8125039 . . . . . . . . . . . . . . . . . . . . . . . . . . 212<br />
N8125040 . . . . . . . . . . . . . . . . . . . . . . . . . . 212<br />
N8125041 . . . . . . . . . . . . . . . . . . . . . . . . . . 212<br />
N8126039 . . . . . . . . . . . . . . . . . . . . . . . . . . 194<br />
N8126040 . . . . . . . . . . . . . . . . . . . . . . . . . . 194<br />
N8126041 . . . . . . . . . . . . . . . . . . . . . . 193-194<br />
N9300030 . . . . . . . . . . . . . . . . . . . . . . . . . . . 95<br />
N9300031 . . . . . . . . . . . . . . . . . . . . . . . . . . . 95<br />
N9300032 . . . . . . . . . . . . . . . . . . . . . . . . . . . 95<br />
N9300033 . . . . . . . . . . . . . . . . . . . . . . . . . . . 95<br />
N9300036 . . . . . . . . . . . . . . . . . . . . . . . . . . . 95<br />
N9300037 . . . . . . . . . . . . . . . . . . . . . . . . . . . 95<br />
N9300038 . . . . . . . . . . . . . . . . . . . . . . . . . . . 95<br />
N9300039 . . . . . . . . . . . . . . . . . . . . . . . . . . . 95<br />
N9300040 . . . . . . . . . . . . . . . . . . . . . . . . . . . 95<br />
N9300041 . . . . . . . . . . . . . . . . . . . . . . . . . . . 95<br />
N9300042 . . . . . . . . . . . . . . . . . . . . . . . . . . . 95<br />
N9300043 . . . . . . . . . . . . . . . . . . . . . . . . . . . 95<br />
N9300044 . . . . . . . . . . . . . . . . . . . . . . . . . . . 95<br />
N9300046 . . . . . . . . . . . . . . . . . . . . . . . . . . . 95<br />
N9300047 . . . . . . . . . . . . . . . . . . . . . . . . . . . 95<br />
N9300048 . . . . . . . . . . . . . . . . . . . . . . . . . . . 95<br />
N9300049 . . . . . . . . . . . . . . . . . . . . . . . . . . . 95<br />
N9300050 . . . . . . . . . . . . . . . . . . . . . . . . . . . 95<br />
N9300051 . . . . . . . . . . . . . . . . . . . . . . . . . . . 95<br />
N9300053 . . . . . . . . . . . . . . . . . . . . . . . . . . . 95<br />
N9300054 . . . . . . . . . . . . . . . . . . . . . . . . . . . 95<br />
N9300055 . . . . . . . . . . . . . . . . . . . . . . . 95, 150<br />
N9300056 . . . . . . . . . . . . . . . . . . . . . . . 95, 150<br />
N9300057 . . . . . . . . . . . . . . . . . . . . . . . . . . . 95<br />
N9300058 . . . . . . . . . . . . . . . . . . . . . . . . . . . 95<br />
N9300059 . . . . . . . . . . . . . . . . . . . . . . . 95, 147<br />
N9300060 . . . . . . . . . . . . . . . . . . . . . . . . . . . 95<br />
N9300061 . . . . . . . . . . . . . . . . . . . . . . . . . . . 95<br />
N9300063 . . . . . . . . . . . . . . . . . . . . . . . . . . . 92<br />
N9300065 . . . . . . . . . . . . . . . . . . . . . . . . . . . 17<br />
N9300066 . . . . . . . . . . . . . . . . . . . . . . . . . . . 17<br />
N9300067 . . . . . . . . . . . . . . . . . . . . . . 197, 223<br />
N9300068 . . . . . . . . . . . . . . . . . . . . . . . . . . . 37<br />
N9300077 . . . . . . . . . . . . . . . . . . . . . . 137, 167<br />
N9300081 . . . . . . . . . . . . . . . . . . . . . . . . . . 167<br />
N9300086 . . . . . . . . . . . . . . . . . . . . . . . . . . 257<br />
N9300087 . . . . . . . . . . . . . . . . . . . . . . . . . . 171<br />
N9300088 . . . . . . . . . . . . . . . . . . . . . . . . . . 170<br />
N9300089 . . . . . . . . . . . . . . . . . . . . . . . . . . 133<br />
N9300090 . . . . . . . . . . . . . . . . . . . . . . . . . . 170<br />
N9300096 . . . . . . . . . . . . . . . . . . . . . . . . . . 135<br />
N9300100 . . . . . . . . . . . . . . . . . . . . . . . . . . . 68<br />
N9300101 . . . . . . . . . . . . . . . . . . . . 66, 68, 234<br />
N9300102 . . . . . . . . . . . . . . . . . . . . . . . . . . . 68<br />
N9300103 . . . . . . . . . . . . . . . . . . . . . . . . . . . 68<br />
N9300104 . . . . . . . . . . . . . . . . . . . . . . . . . . . 68<br />
N9300105 . . . . . . . . . . . . . . . . . . . . . . . . . . . 68<br />
N9300106 . . . . . . . . . . . . . . . . . . . . . . . . . . . 68<br />
N9300107 . . . . . . . . . . . . . . . . . . . . . . . . . . . 68<br />
N9300108 . . . . . . . . . . . . . . . . . . . . . . . . . . . 68<br />
N9300110 . . . . . . . . . . . . . . . . . . . . . . . . . . . 68<br />
N9300111 . . . . . . . . . . . . . . . . . . . . . . . . . . . 68<br />
N9300112 . . . . . . . . . . . . . . . . . . . . . . . . . . . 68<br />
N9300113 . . . . . . . . . . . . . . . . . . . . . . . . . . . 68<br />
N9300114 . . . . . . . . . . . . . . . . . . . . . . . . . . . 68<br />
N9300115 . . . . . . . . . . . . . . . . . . . . . . . . . . . 68<br />
N9300116 . . . . . . . . . . . . . . . . . . . . . . . . . . . 68<br />
N9300117 . . . . . . . . . . . . . . . . . . . . . . . . . . . 68<br />
N9300118 . . . . . . . . . . . . . . . . . . . . . . . . . . . 68<br />
N9300119 . . . . . . . . . . . . . . . . . . . . . . . . . . . 68<br />
N9300120 . . . . . . . . . . . . . . . . . . . . . . . . . . . 68<br />
N9300121 . . . . . . . . . . . . . . . . . . . . . . . . . . . 68<br />
N9300122 . . . . . . . . . . . . . . . . . . . . . . . . . . . 68<br />
N9300123 . . . . . . . . . . . . . . . . . . . . . . . . . . . 68<br />
N9300124 . . . . . . . . . . . . . . . . . . . . . . . . . . . 68<br />
N9300125 . . . . . . . . . . . . . . . . . . . . . . . . . . . 68<br />
N9300126 . . . . . . . . . . . . . . . . . . . . . . . . . . . 68<br />
N9300127 . . . . . . . . . . . . . . . . . . . . . . . . . . . 68<br />
N9300128 . . . . . . . . . . . . . . . . . . . . . . . . . . . 68<br />
N9300129 . . . . . . . . . . . . . . . . . . . . . . . . . . . 68<br />
N9300130 . . . . . . . . . . . . . . . . . . . . . . . . . . . 68<br />
N9300131 . . . . . . . . . . . . . . . . . . . . . . . . . . . 68<br />
N9300132 . . . . . . . . . . . . . . . . . . . . . . . . . . . 68<br />
N9300133 . . . . . . . . . . . . . . . . . . . . . . . . 66, 68<br />
N9300134 . . . . . . . . . . . . . . . . . . . . . . . . . . . 69<br />
N9300135 . . . . . . . . . . . . . . . . . . . . . . . . . . . 69<br />
N9300136 . . . . . . . . . . . . . . . . . . . . . . . . . . . 69<br />
N9300137 . . . . . . . . . . . . . . . . . . . . . . . . . . . 69<br />
N9300138 . . . . . . . . . . . . . . . . . . . . . . . . . . . 69<br />
N9300139 . . . . . . . . . . . . . . . . . . . . . . . . . . . 69<br />
N9300140 . . . . . . . . . . . . . . . . . . . . . . . . . . . 69<br />
N9300141 . . . . . . . . . . . . . . . . . . . . . . . . . . . 69<br />
N9300142 . . . . . . . . . . . . . . . . . . . . . . . . . . . 69<br />
N9300143 . . . . . . . . . . . . . . . . . . . . . . . . . . . 69<br />
N9300144 . . . . . . . . . . . . . . . . . . . . . . . . . . . 69<br />
N9300145 . . . . . . . . . . . . . . . . . . . . . . . . . . . 69<br />
N9300146 . . . . . . . . . . . . . . . . . . . . . . . . . . . 69<br />
N9300147 . . . . . . . . . . . . . . . . . . . . . . . . . . . 69<br />
N9300148 . . . . . . . . . . . . . . . . . . . . . . . . . . . 69<br />
N9300149 . . . . . . . . . . . . . . . . . . . . . . . . . . . 69<br />
N9300150 . . . . . . . . . . . . . . . . . . . . . . . . . . . 69<br />
N9300151 . . . . . . . . . . . . . . . . . . . . . . . . . . . 69<br />
N9300152 . . . . . . . . . . . . . . . . . . . . . . . . . . . 69<br />
N9300153 . . . . . . . . . . . . . . . . . . . . . . . . . . . 69<br />
N9300154 . . . . . . . . . . . . . . . . . . . . . . . . . . . 69<br />
N9300155 . . . . . . . . . . . . . . . . . . . . . . . . . . . 69<br />
N9300156 . . . . . . . . . . . . . . . . . . . . . . . . . . . 69<br />
N9300157 . . . . . . . . . . . . . . . . . . . . . . . . . . . 69<br />
N9300158 . . . . . . . . . . . . . . . . . . . . . . . . . . . 69<br />
N9300160 . . . . . . . . . . . . . . . . . . . . . . . . . . . 69<br />
N9300161 . . . . . . . . . . . . . . . . . . . . . . . . . . . 69<br />
N9300162 . . . . . . . . . . . . . . . . . . . . . . . . . . . 69<br />
N9300163 . . . . . . . . . . . . . . . . . . . . . . . . . . . 69<br />
N9300165 . . . . . . . . . . . . . . . . . . . . . . . . . . . 69<br />
N9300166 . . . . . . . . . . . . . . . . . . . . . . . . . . . 69<br />
N9300167 . . . . . . . . . . . . . . . . . . . . . . . . . . . 69<br />
N9300168 . . . . . . . . . . . . . . . . . . . . . . . . . . . 69<br />
N9300169 . . . . . . . . . . . . . . . . . . . . . . . . . . . 69<br />
N9300170 . . . . . . . . . . . . . . . . . . . . . . . . . . . 69<br />
N9300171 . . . . . . . . . . . . . . . . . . . . . . . . . . . 69<br />
N9300172 . . . . . . . . . . . . . . . . . . . . . . . . . . . 68<br />
N9300173 . . . . . . . . . . . . . . . . . . . . . . . . . . . 68<br />
N9300174 . . . . . . . . . . . . . . . . . . . . . . . . . . . 68<br />
N9300175 . . . . . . . . . . . . . . . . . . . . . . . . . . . 68<br />
N9300176 . . . . . . . . . . . . . . . . . . . . . . . . . . . 68<br />
N9300177 . . . . . . . . . . . . . . . . . . . . . . . . . . . 69<br />
N9300178 . . . . . . . . . . . . . . . . . . . . . . . . . . . 69<br />
N9300179 . . . . . . . . . . . . . . . . . . . . . . . . . . . 68<br />
N9300180 . . . . . . . . . . . . . . . . . . . . . . . . . . . 68<br />
N9300181 . . . . . . . . . . . . . . . . . . . . . . . . . . . 68<br />
N9300182 . . . . . . . . . . . . . . . . . . . . . . . . . . . 69<br />
N9300183 . . . . . . . . . . . . . . . . . . . . . . . . . . . 68<br />
N9300184 . . . . . . . . . . . . . . . . . . . . . . . . . . . 68<br />
N9300200 . . . . . . . . . . . . . . . . . . . . . . . . . . 234<br />
N9300201 . . . . . . . . . . . . . . . . . . . . . . . . . . 234<br />
N9300202 . . . . . . . . . . . . . . . . . . . . . . . . . . 234<br />
N9300203 . . . . . . . . . . . . . . . . . . . . . . . . . . 235<br />
N9300204 . . . . . . . . . . . . . . . . . . . . . . . . . . 235<br />
N9300205 . . . . . . . . . . . . . . . . . . . . . . . . . . 234<br />
N9300207 . . . . . . . . . . . . . . . . . . . . . . . . . . . 68<br />
N9300208 . . . . . . . . . . . . . . . . . . . . . . . . . . 234<br />
N9300211 . . . . . . . . . . . . . . . . . . . . . . . 67, 233<br />
N9300212 . . . . . . . . . . . . . . . . . . . . . . . 67, 233<br />
N9300213 . . . . . . . . . . . . . . . . . . . . . . . 67, 233<br />
N9300214 . . . . . . . . . . . . . . . . . . . . . . . 66, 232<br />
N9300215 . . . . . . . . . . . . . . . . . . . . . . . 66, 232<br />
N9300216 . . . . . . . . . . . . . . . . . . . . . . . . . . 232<br />
N9300217 . . . . . . . . . . . . . . . . . . . . . . . . . . 232<br />
N9300218 . . . . . . . . . . . . . . . . . . . . . . . . . . . 66<br />
N9300219 . . . . . . . . . . . . . . . . . . . . . . . . . . . 66<br />
N9300220 . . . . . . . . . . . . . . . . . . . . . . . . . . . 66<br />
N9300221 . . . . . . . . . . . . . . . . . . . . . . . . . . . 66<br />
N9300224 . . . . . . . . . . . . . . . . . . . . . . . . . . . 67<br />
N9300225 . . . . . . . . . . . . . . . . . . . . . . . . . . 232<br />
N9300226 . . . . . . . . . . . . . . . . . . . . . . . . . . 233<br />
N9300227 . . . . . . . . . . . . . . . . . . . . . . . . . . 233<br />
N9300228 . . . . . . . . . . . . . . . . . . . . . . . . . . 233<br />
N9300229 . . . . . . . . . . . . . . . . . . . . . . . . . . 234<br />
N9300230 . . . . . . . . . . . . . . . . . . . . . . . . . . 234<br />
N9300231 . . . . . . . . . . . . . . . . . . . . . . . . . . 211<br />
N9300232 . . . . . . . . . . . . . . . . . . . . . . . . . . 211<br />
Part No. Page Part No. Page Part No. Page
N9300233 – N9302846 Part Number Index<br />
Index<br />
Part Number<br />
423<br />
N9300233 . . . . . . . . . . . . . . . . . . . . . . . . . . 211<br />
N9300234 . . . . . . . . . . . . . . . . . . . . . . . . . . 211<br />
N9300235 . . . . . . . . . . . . . . . . . . . . . . . . . . 212<br />
N9300241 . . . . . . . . . . . . . . . . . . . . . . . . . . 235<br />
N9300244 . . . . . . . . . . . . . . . . . . . . . . . . . . . 66<br />
N9300260 . . . . . . . . . . . . . . . . . . . . . . . . . . . 67<br />
N9300280 . . . . . . . . . . . . . . . . . . . . . . . . . . 235<br />
N9300281 . . . . . . . . . . . . . . . . . . . . . . . . . . 235<br />
N9301001 . . . . . . . . . . . . . . . . . . . . . . . . . . 323<br />
N9301002 . . . . . . . . . . . . . . . . . . . . . . . . . . 323<br />
N9301029 . . . . . . . . . . . . . . . . . . . . . . . . . . 327<br />
N9301063 . . . . . . . . . . . . . . . . . . . . . . . . . . 327<br />
N9301067 . . . . . . . . . . . . . . . . . . . . . . . . . . 327<br />
N9301068 . . . . . . . . . . . . . . . . . . . . . . . . . . 327<br />
N9301167 . . . . . . . . . . . . . . . . . . . . . . . . . . . 93<br />
N9301169 . . . . . . . . . . . . . . . . . . . . . . . . . . . 93<br />
N9301170 . . . . . . . . . . . . . . . . . . . . . . . . . . . 93<br />
N9301171 . . . . . . . . . . . . . . . . . . . . . . . . . . . 93<br />
N9301172 . . . . . . . . . . . . . . . . . . . . . . . . . . . 93<br />
N9301176 . . . . . . . . . . . . . . . . . . 163, 354, 367<br />
N9301177 . . . . . . . . . . . . . . . . . . . . . . . . . . 163<br />
N9301178 . . . . . . . . . . . . . . . . . . 163, 354, 367<br />
N9301179 . . . . . . . . . . . . . . . . . . . . . . . . . . 163<br />
N9301191 . . . . . . . . . . . . . . . . . . . . . . . . . . 163<br />
N9301192 . . . . . . . . . . . . . . . . . . . . . . . . . . 163<br />
N9301193 . . . . . . . . . . . . . . . . . . . . . . . . . . 163<br />
N9301204 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8<br />
N9301205 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8<br />
N9301221 . . . . . . . . . . . . . . . . . . . . . . . . . . . 95<br />
N9301222 . . . . . . . . . . . . . . . . . . . . . . . . . . . 95<br />
N9301223 . . . . . . . . . . . . . . . . . . . . . . . . . . . 95<br />
N9301225 . . . . . . . . . . . . . . . . . . . . . . . . . . . 95<br />
N9301226 . . . . . . . . . . . . . . . . . . . . . . . . . . . 95<br />
N9301227 . . . . . . . . . . . . . . . . . . . . . . . . . . . 95<br />
N9301233 . . . . . . . . . . . . . . . . . . . . . . . . . . . 95<br />
N9301253 . . . . . . . . . . . . . . . . . . . . . . . . . . . 95<br />
N9301254 . . . . . . . . . . . . . . . . . . . . . . . . . . . 95<br />
N9301255 . . . . . . . . . . . . . . . . . . . . . . . . . . . 95<br />
N9301259 . . . . . . . . . . . . . . . . . . . . . . . . . . . 95<br />
N9301266 . . . . . . . . . . . . . . . . . . . . . . . . . . . 95<br />
N9301267 . . . . . . . . . . . . . . . . . . . . . . . . . . . 95<br />
N9301268 . . . . . . . . . . . . . . . . . . . . . . . . . . . 95<br />
N9301269 . . . . . . . . . . . . . . . . . . . . . . . . . . . 95<br />
N9301270 . . . . . . . . . . . . . . . . . . . 90, 149, 272<br />
N9301272 . . . . . . . . . . . . . . . . . . . . . . 132, 137<br />
N9301298 . . . . . . . . . . . . . . . . . . . . . . 165, 354<br />
N9301299 . . . . . . . . . . . . . . . . . . . . . . 165, 354<br />
N9301303 . . . . . . . . . . . . . . . . . . . . . . . . . . . 89<br />
N9301304 . . . . . . . . . . . . . . . . . . . . . . . . . . . 89<br />
N9301324 . . . . . . . . . . . . . . . . . . . . . . 167, 354<br />
N9301325 . . . . . . . . . . . . . . . . . . . . . . . . . . 167<br />
N9301327 . . . . . . . . . . . . . . . . . . . . . . . . . . 167<br />
N9301328 . . . . . . . . . . . . . . . . . . . . . . . . . . 167<br />
N9301338 . . . . . . . . . . . . . . . . . . . . . . . . . . . 93<br />
N9301340 . . . . . . . . . . . . . . . . . . . . . . . . . . . 93<br />
N9301341 . . . . . . . . . . . . . . . . . . . . . . . . . . . 93<br />
N9301342 . . . . . . . . . . . . . . . . . . . . . . . . . . . 93<br />
N9301343 . . . . . . . . . . . . . . . . . . . . . . . . . . . 93<br />
N9301346 . . . . . . . . . . . . . . . . . . . . . . . . . . . 93<br />
N9301354 . . . . . . . . . . . . . . . . . . . . . . . . . . . 93<br />
N9301355 . . . . . . . . . . . . . . . . . . . . . . . 93, 180<br />
N9301356 . . . . . . . . . . . . . . . . . . . 93, 144, 147<br />
N9301357 . . . . . . . . . . . . . . . . . . . 93, 144, 147<br />
N9301358 . . . . . . . . . . . . . . . . . . . . . . . . . . . 93<br />
N9301360 . . . . . . . . . . . . . . . . . . . . . . . . . . . 94<br />
N9301361 . . . . . . . . . . . . . . . . . . . . . . . . . . . 94<br />
N9301376 . . . . . . . . . . . . . . . . . . . 92, 132, 137<br />
N9301385 . . . . . . . . . . . . . . . . . . . . . . . 89, 271<br />
N9301390 . . . . . . . . . . . . . . . . . . . . . . . . . . . 90<br />
N9301398 . . . . . . . . . . . . . . . . . . . . . . . . . . . 36<br />
N9301399 . . . . . . . . . . . . . . . . . . . . . . . . . . . 36<br />
N9301710 . . . . . . . . . . . . . . . . . . . . . . . . . . . 36<br />
N9301711 . . . . . . . . . . . . . . . . . . . . . . . . . . . 36<br />
N9301712 . . . . . . . . . . . . . . . . . . . . . . . . . . . 36<br />
N9301714 . . . . . . . . . . . . . . . . . . . . . . . . . . . 36<br />
N9301715 . . . . . . . . . . . . . . . . . . . . . . . . . . . 36<br />
N9301720 . . . . . . . . . . . . . . . . . . . . . . . . . . 211<br />
N9301730 . . . . . . . . . . . . . . . . . . . . . . . . . . 137<br />
N9302081 . . . . . . . . . . . . . . . . . . . . . . . . . . . 94<br />
N9302130 . . . . . . . . . . . . . . . . . . . . . . . . . . 208<br />
N9302134 . . . . . . . . . . . . . . . . . . . . . . . . . . 271<br />
N9302136 . . . . . . . . . . . . . . . . . . . . . . . . . . 271<br />
N9302141 . . . . . . . . . . . . . . . . . . . . . . . . . . 271<br />
N9302143 . . . . . . . . . . . . . . . . . . . . . . . . . . 271<br />
N9302145 . . . . . . . . . . . . . . . . . . . . . . . . . . 166<br />
N9302146 . . . . . . . . . . . . . . . . . . . . . . . . . . 166<br />
N9302149 . . . . . . . . . . . . . . . . . . . . . . . . . . . 93<br />
N9302197 . . . . . . . . . . . . . . . . . . . . . . . . . . . 36<br />
N9302199 . . . . . . . . . . . . . . . . . . . . . . . . . . . 36<br />
N9302202 . . . . . . . . . . . . . . . . . . . . . . . . . . 161<br />
N9302203 . . . . . . . . . . . . . . . . . . . . . . . . . . 161<br />
N9302204 . . . . . . . . . . . . . . . . . . . . . . . . . . 161<br />
N9302210 . . . . . . . . . . . . . . . . . . . . . . . . . . 161<br />
N9302211 . . . . . . . . . . . . . . . . . . . . . . . . . . 161<br />
N9302212 . . . . . . . . . . . . . . . . . . . . . . . . . . 161<br />
N9302213 . . . . . . . . . . . . . . . . . . . . . . . . . . 161<br />
N9302214 . . . . . . . . . . . . . . . . . . . . . . . . . . 161<br />
N9302215 . . . . . . . . . . . . . . . . . . . . . . . . . . 161<br />
N9302220 . . . . . . . . . . . . . . . . . . . . . . . . . . 162<br />
N9302222 . . . . . . . . . . . . . . . . . . . . . . . . . . 162<br />
N9302224 . . . . . . . . . . . . . . . . . . . . . . . . . . 162<br />
N9302226 . . . . . . . . . . . . . . . . . . . . . . . . . . 162<br />
N9302230 . . . . . . . . . . . . . . . . . . . . . . . . . . 161<br />
N9302231 . . . . . . . . . . . . . . . . . . . . . . . . . . 162<br />
N9302235 . . . . . . . . . . . . . . . . . . . . . . . . . . 162<br />
N9302237 . . . . . . . . . . . . . . . . . . . . . . . . . . 162<br />
N9302240 . . . . . . . . . . . . . . . . . . . . . . . . . . 162<br />
N9302241 . . . . . . . . . . . . . . . . . . . . . . . . . . 162<br />
N9302242 . . . . . . . . . . . . . . . . . . . . . . . . . . 162<br />
N9302243 . . . . . . . . . . . . . . . . . . . . . . . . . . 162<br />
N9302244 . . . . . . . . . . . . . . . . . . . . . . . . . . 162<br />
N9302245 . . . . . . . . . . . . . . . . . . . . . . . . . . 162<br />
N9302247 . . . . . . . . . . . . . . . . . . . . . . . . . . 162<br />
N9302250 . . . . . . . . . . . . . . . . . . . . . . . . . . 162<br />
N9302251 . . . . . . . . . . . . . . . . . . . . . . . . . . 162<br />
N9302253 . . . . . . . . . . . . . . . . . . . . . . . . . . 162<br />
N9302254 . . . . . . . . . . . . . . . . . . . . . . . . . . 162<br />
N9302256 . . . . . . . . . . . . . . . . . . . . . . . . . . 162<br />
N9302257 . . . . . . . . . . . . . . . . . . . . . . . . . . 162<br />
N9302259 . . . . . . . . . . . . . . . . . . . . . . . . . . 162<br />
N9302262 . . . . . . . . . . . . . . . . . . . . . . . . . . 162<br />
N9302265 . . . . . . . . . . . . . . . . . . . . . . . . . . 162<br />
N9302266 . . . . . . . . . . . . . . . . . . . . . . . . . . 162<br />
N9302560 . . . . . . . . . . . . . . . . . . . . . . . . . . 270<br />
N9302561 . . . . . . . . . . . . . . . . . . . . . . . . . . 270<br />
N9302562 . . . . . . . . . . . . . . . . . . . . . . . . . . 270<br />
N9302563 . . . . . . . . . . . . . . . . . . . . . . . . . . 270<br />
N9302564 . . . . . . . . . . . . . . . . . . . . . . . . . . 270<br />
N9302565 . . . . . . . . . . . . . . . . . . . . . . . . . . 270<br />
N9302567 . . . . . . . . . . . . . . . . . . . . . . . 90, 272<br />
N9302568 . . . . . . . . . . . . . . . . . . . . . . . . . . . 90<br />
N9302569 . . . . . . . . . . . . . . . . . . . . . . . 90, 272<br />
N9302570 . . . . . . . . . . . . . . . . . . . . . . . 90, 272<br />
N9302571 . . . . . . . . . . . . . . . . . . . . . . . . . . 149<br />
N9302572 . . . . . . . . . . . . . . . . . . . . . . . . . . 149<br />
N9302573 . . . . . . . . . . . . . . . . . . . . . . . . . . 149<br />
N9302574 . . . . . . . . . . . . . . . . . . . . . . . . . . 149<br />
N9302575 . . . . . . . . . . . . . . . . . . . . . . . 90, 272<br />
N9302576 . . . . . . . . . . . . . . . . . . . . . . . . . . . 90<br />
N9302577 . . . . . . . . . . . . . . . . . . . . . . . 90, 272<br />
N9302578 . . . . . . . . . . . . . . . . . . . . . . . . . . . 90<br />
N9302579 . . . . . . . . . . . . . . . . . . . . . . 149, 272<br />
N9302580 . . . . . . . . . . . . . . . . . . . . . . . . . . 149<br />
N9302581 . . . . . . . . . . . . . . . . . . . . . . . . . . 149<br />
N9302582 . . . . . . . . . . . . . . . . . . . . . . . . . . 149<br />
N9302585 . . . . . . . . . . . . . . . . . . . 90, 149, 272<br />
N9302600 . . . . . . . . . . . . . . . . . . . . . . . . . . 253<br />
N9302603 . . . . . . . . . . . . . . . . . . . . . . . . . . 253<br />
N9302604 . . . . . . . . . . . . . . . . . . . . . . . . . . 253<br />
N9302605 . . . . . . . . . . . . . . . . . . . . . . . . . . 253<br />
N9302606 . . . . . . . . . . . . . . . . . . . . . . . . . . 253<br />
N9302607 . . . . . . . . . . . . . . . . . . . . . . . . . . 253<br />
N9302608 . . . . . . . . . . . . . . . . . . . . . . . . . . 253<br />
N9302609 . . . . . . . . . . . . . . . . . . . . . . . . . . 253<br />
N9302610 . . . . . . . . . . . . . . . . . . . . . . . . . . 253<br />
N9302611 . . . . . . . . . . . . . . . . . . . . . . . . . . 253<br />
N9302612 . . . . . . . . . . . . . . . . . . . . . . . . . . 253<br />
N9302613 . . . . . . . . . . . . . . . . . . . . . . . . . . 253<br />
N9302614 . . . . . . . . . . . . . . . . . . . . . . . . . . 253<br />
N9302615 . . . . . . . . . . . . . . . . . . . . . . . . . . 253<br />
N9302618 . . . . . . . . . . . . . . . . . . . . . . . . . . 252<br />
N9302619 . . . . . . . . . . . . . . . . . . . . . . . . . . 253<br />
N9302620 . . . . . . . . . . . . . . . . . . . . . . . . . . 249<br />
N9302622 . . . . . . . . . . . . . . . . . . . . . . . . . . 253<br />
N9302640 . . . . . . . . . . . . . . . . . . . . . . . . . . 249<br />
N9302642 . . . . . . . . . . . . . . . . . . . . . . . . . . 250<br />
N9302643 . . . . . . . . . . . . . . . . . . . . . . . . . . 250<br />
N9302650 . . . . . . . . . . . . . . . . . . . . . . . . . . 327<br />
N9302676 . . . . . . . . . . . . . . . . . . . . . . . . . . 323<br />
N9302677 . . . . . . . . . . . . . . . . . . . . . . . . . . 325<br />
N9302678 . . . . . . . . . . . . . . . . . . . . . . . . . . 327<br />
N9302680 . . . . . . . . . . . . . . . . . . . . . . . 89, 271<br />
N9302681 . . . . . . . . . . . . . . . . . . . . . . . . . . . 89<br />
N9302682 . . . . . . . . . . . . . . . . . . . . . . . . . . . 89<br />
N9302684 . . . . . . . . . . . . . . . . . . . . . . . 89, 271<br />
N9302685 . . . . . . . . . . . . . . . . . . . . . . . 89, 271<br />
N9302686 . . . . . . . . . . . . . . . . . . . . . . . 89, 271<br />
N9302698 . . . . . . . . . . . . . . . . . . . . . . . . . . 134<br />
N9302736 . . . . . . . . . . . . . . . . . . . . . . . . . . 386<br />
N9302780 . . . . . . . . . . . . . . . . . . . . . . . . . . . 89<br />
N9302781 . . . . . . . . . . . . . . . . . . . . . . . . . . 171<br />
N9302782 . . . . . . . . . . . . . . . . . . . . . . . . . . 150<br />
N9302783 . . . . . . . . . . . . . . . . . . . . . . . . . . 150<br />
N9302784 . . . . . . . . . . . . . . . . . . . . . . . . . . . 89<br />
N9302785 . . . . . . . . . . . . . . . . . . . . . . . 90, 149<br />
N9302799 . . . . . . . . . . . . . . . . . . . . . . . 88, 161<br />
N9302800 . . . . . . . . . . . . . . . . . . . . . . . . . . 169<br />
N9302802 . . . . . . . . . . . . . . . . . . . . . . . . . . 169<br />
N9302803 . . . . . . . . . . . . . . . . . . . . . . . . . . 169<br />
N9302808 . . . . . . . . . . . . . . . . . . . . . . . . . . 169<br />
N9302809 . . . . . . . . . . . . . . . . . . . . . . . . . . 168<br />
N9302810 . . . . . . . . . . . . . . . . . . . . . . . . . . 168<br />
N9302811 . . . . . . . . . . . . . . . . . . . . . . . . . . 168<br />
N9302812 . . . . . . . . . . . . . . . . . . . . . . . . . . 168<br />
N9302813 . . . . . . . . . . . . . . . . . . . . . . . . . . 168<br />
N9302814 . . . . . . . . . . . . . . . . . . . . . . . . . . 168<br />
N9302815 . . . . . . . . . . . . . . . . . . . . . . . . . . 168<br />
N9302816 . . . . . . . . . . . . . . . . . . . . . . . . . . 168<br />
N9302817 . . . . . . . . . . . . . . . . . . . . . . . . . . 168<br />
N9302818 . . . . . . . . . . . . . . . . . . . . . . . . . . 168<br />
N9302819 . . . . . . . . . . . . . . . . . . . . . . . . . . 168<br />
N9302820 . . . . . . . . . . . . . . . . . . . . . . . . . . 168<br />
N9302821 . . . . . . . . . . . . . . . . . . . . . . . . . . 171<br />
N9302823 . . . . . . . . . . . . . . . . . . . . . . . . . . 170<br />
N9302825 . . . . . . . . . . . . . . . . . . . . . . . . . . 170<br />
N9302827 . . . . . . . . . . . . . . . . . . . . . . . . . . 170<br />
N9302832 . . . . . . . . . . . . . . . . . . . . . . 147, 172<br />
N9302833 . . . . . . . . . . . . . . . . . . . . . . . . . . 172<br />
N9302835 . . . . . . . . . . . . . . . . . . . . . . . . . . 172<br />
N9302836 . . . . . . . . . . . . . . . . . . . . . . . . . . 172<br />
N9302838 . . . . . . . . . . . . . . . . . . . . . . . . . . 172<br />
N9302839 . . . . . . . . . . . . . . . . . . . . . . . . . . 172<br />
N9302840 . . . . . . . . . . . . . . . . . . . . . . . . . . 172<br />
N9302841 . . . . . . . . . . . . . . . . . . . . . . . . . . 172<br />
N9302843 . . . . . . . . . . . . . . . . . . . . . . . . . . 172<br />
N9302846 . . . . . . . . . . . . . . . . . . . . . . . . . . 170<br />
Part No. Page Part No. Page Part No. Page<br />
See page 4 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
See page 2 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong>
Index Part Number N9302847 – N9303643<br />
Index<br />
Part Number<br />
424<br />
N9302847 . . . . . . . . . . . . . . . . . . . . . . . . . . 170<br />
N9302848 . . . . . . . . . . . . . . . . . . . . . . . . . . 170<br />
N9302849 . . . . . . . . . . . . . . . . . . . . . . . . . . 170<br />
N9302850 . . . . . . . . . . . . . . . . . . . . . . . . . . 170<br />
N9302851 . . . . . . . . . . . . . . . . . . . . . . . . . . 169<br />
N9302852 . . . . . . . . . . . . . . . . . . . . . . . . . . 169<br />
N9302853 . . . . . . . . . . . . . . . . . . . . . . . . . . 169<br />
N9302854 . . . . . . . . . . . . . . . . . . . . . . . . . . 169<br />
N9302855 . . . . . . . . . . . . . . . . . . . . . . . . . . 169<br />
N9302857 . . . . . . . . . . . . . . . . . . . . . . . . . . 169<br />
N9302858 . . . . . . . . . . . . . . . . . . . . . . . . . . 169<br />
N9302859 . . . . . . . . . . . . . . . . . . . . . . . . . . 169<br />
N9302860 . . . . . . . . . . . . . . . . . . . . . . . . . . 169<br />
N9302862 . . . . . . . . . . . . . . . . . . . . . . . . . . 169<br />
N9302866 . . . . . . . . . . . . . . . . . . . . . . . . . . 169<br />
N9302867 . . . . . . . . . . . . . . . . . . . . . . . . . . 169<br />
N9302868 . . . . . . . . . . . . . . . . . . . . . . . . . . 169<br />
N9302871 . . . . . . . . . . . . . . . . . . . . . . . . . . 171<br />
N9302872 . . . . . . . . . . . . . . . . . . . . . . . . . . 171<br />
N9302881 . . . . . . . . . . . . . . . . . . . . . . . . . . 170<br />
N9302882 . . . . . . . . . . . . . . . . . . . . . . . . . . 170<br />
N9302885 . . . . . . . . . . . . . . . . . . . . . . . . . . 168<br />
N9302886 . . . . . . . . . . . . . . . . . . . . . . . . . . 170<br />
N9302889 . . . . . . . . . . . . . . . . . . . . . . . . . . 169<br />
N9302890 . . . . . . . . . . . . . . . . . . . . . . . . . . 169<br />
N9302897 . . . . . . . . . . . . . . . . . . . . . . . . . . 168<br />
N9302899 . . . . . . . . . . . . . . . . . . . . . . . . . . 168<br />
N9302901 . . . . . . . . . . . . . . . . . . . . . . . . . . 168<br />
N9302903 . . . . . . . . . . . . . . . . . . . . . . . . . . 168<br />
N9302905 . . . . . . . . . . . . . . . . . . . . . . . . . . 168<br />
N9302908 . . . . . . . . . . . . . . . . . . . . . . . . . . 170<br />
N9302909 . . . . . . . . . . . . . . . . . . . . . . . . . . 171<br />
N9302910 . . . . . . . . . . . . . . . . . . . . . . . . . . 171<br />
N9302911 . . . . . . . . . . . . . . . . . . . . . . . . . . 171<br />
N9302912 . . . . . . . . . . . . . . . . . . . . . . . . . . 171<br />
N9302913 . . . . . . . . . . . . . . . . . . . . . . . . . . 170<br />
N9302914 . . . . . . . . . . . . . . . . . . . . . . . . . . 170<br />
N9302917 . . . . . . . . . . . . . . . . . . . . . . . . . . 172<br />
N9302918 . . . . . . . . . . . . . . . . . . . . . . . . . . 172<br />
N9302919 . . . . . . . . . . . . . . . . . . . . . . . . . . 172<br />
N9302920 . . . . . . . . . . . . . . . . . . . . . . . . . . 172<br />
N9302921 . . . . . . . . . . . . . . . . . . . . . . . . . . 172<br />
N9302922 . . . . . . . . . . . . . . . . . . . . . . . . . . 171<br />
N9302945 . . . . . . . . . . . . . . . . . . . . . . . . . . . 89<br />
N9302946 . . . . . . . . . . . . . . . . . . . . . . . . . . 236<br />
N9302950 . . . . . . . . . . . . . . . . . . . . . . . . . . 169<br />
N9302951 . . . . . . . . . . . . . . . . . . . . . . . . . . 169<br />
N9302952 . . . . . . . . . . . . . . . . . . . . . . . . . . 169<br />
N9302953 . . . . . . . . . . . . . . . . . . . . . . . . . . 169<br />
N9302954 . . . . . . . . . . . . . . . . . . . . . . . . . . 169<br />
N9302956 . . . . . . . . . . . . . . . . . . . . . . . . . . 169<br />
N9302957 . . . . . . . . . . . . . . . . . . . . . . . . . . 169<br />
N9302958 . . . . . . . . . . . . . . . . . . . . . . . . . . 169<br />
N9302960 . . . . . . . . . . . . . . . . . . . . . . . . . . 169<br />
N9302961 . . . . . . . . . . . . . . . . . . . . . . . . . . 169<br />
N9302962 . . . . . . . . . . . . . . . . . . . . . . . . . . 169<br />
N9302965 . . . . . . . . . . . . . . . . . . . . . . . . . . 169<br />
N9302966 . . . . . . . . . . . . . . . . . . . . . . . . . . 169<br />
N9302967 . . . . . . . . . . . . . . . . . . . . . . . . . . 169<br />
N9302972 . . . . . . . . . . . . . . . . . . 132, 137, 159<br />
N9302974 . . . . . . . . . . . . . . . . . . . . . . . . . . 167<br />
N9303314 . . . . . . . . . . . . . . . . . . . . . . . . . . 167<br />
N9303343 . . . . . . . . . . . . . . . . . . . . . . . . . . 159<br />
N9303344 . . . . . . . . . . . . . . . . . . . . . . 150, 159<br />
N9303345 . . . . . . . . . . . . . . . . . . . . . . 150, 159<br />
N9303396 . . . . . . . . . . . . . . . . . . . . . . . . . . 289<br />
N9303429 . . . . . . . . . . . . . . . . . . . . . . . . . . 167<br />
N9303430 . . . . . . . . . . . . . . . . . . . . . . . . . . 308<br />
N9303441 . . . . . . . . . . . . . . . . . . . . . . . . . . . 89<br />
N9303442 . . . . . . . . . . . . . . . . . . . . . . . . . . . 89<br />
N9303445 . . . . . . . . . . . . . . . . . . . . . 32, 35, 67<br />
N9303448 . . . . . . . . . . . . . . . . . . . . . . . . . . . 93<br />
N9303500 . . . . . . . . . . . . . . . . . . . . . . . . . . 308<br />
N9303501 . . . . . . . . . . . . . . . . . . . . . . . . . . 308<br />
N9303502 . . . . . . . . . . . . . . . . . . . . . . . . . . 308<br />
N9303503 . . . . . . . . . . . . . . . . . . . . . . . . . . 308<br />
N9303504 . . . . . . . . . . . . . . . . . . . . . . . . . . 308<br />
N9303505 . . . . . . . . . . . . . . . . . . . . . . . . . . 308<br />
N9303506 . . . . . . . . . . . . . . . . . . . . . . . . . . 308<br />
N9303507 . . . . . . . . . . . . . . . . . . . . . . . . . . 308<br />
N9303508 . . . . . . . . . . . . . . . . . . . . . . . . . . 308<br />
N9303509 . . . . . . . . . . . . . . . . . . . . . . . . . . 308<br />
N9303510 . . . . . . . . . . . . . . . . . . . . . . . . . . 308<br />
N9303511 . . . . . . . . . . . . . . . . . . . . . . . . . . 308<br />
N9303512 . . . . . . . . . . . . . . . . . . . . . . . . . . 308<br />
N9303513 . . . . . . . . . . . . . . . . . . . . . . . . . . 308<br />
N9303514 . . . . . . . . . . . . . . . . . . . . . . . . . . 308<br />
N9303515 . . . . . . . . . . . . . . . . . . . . . . . . . . 308<br />
N9303516 . . . . . . . . . . . . . . . . . . . . . . . . . . 308<br />
N9303517 . . . . . . . . . . . . . . . . . . . . . . . . . . 308<br />
N9303518 . . . . . . . . . . . . . . . . . . . . . . . . . . 308<br />
N9303519 . . . . . . . . . . . . . . . . . . . . . . . . . . 308<br />
N9303520 . . . . . . . . . . . . . . . . . . . . . . . . . . 308<br />
N9303521 . . . . . . . . . . . . . . . . . . . . . . . . . . 308<br />
N9303522 . . . . . . . . . . . . . . . . . . . . . . . . . . 308<br />
N9303523 . . . . . . . . . . . . . . . . . . . . . . . . . . 308<br />
N9303524 . . . . . . . . . . . . . . . . . . . . . . . . . . 308<br />
N9303525 . . . . . . . . . . . . . . . . . . . . . . . . . . 308<br />
N9303526 . . . . . . . . . . . . . . . . . . . . . . . . . . 308<br />
N9303527 . . . . . . . . . . . . . . . . . . . . . . . . . . 308<br />
N9303528 . . . . . . . . . . . . . . . . . . . . . . . . . . 308<br />
N9303529 . . . . . . . . . . . . . . . . . . . . . . . . . . 308<br />
N9303530 . . . . . . . . . . . . . . . . . . . . . . . . . . 308<br />
N9303531 . . . . . . . . . . . . . . . . . . . . . . . . . . 308<br />
N9303532 . . . . . . . . . . . . . . . . . . . . . . . . . . 311<br />
N9303533 . . . . . . . . . . . . . . . . . . . . . . . . . . 311<br />
N9303534 . . . . . . . . . . . . . . . . . . . . . . . . . . 311<br />
N9303535 . . . . . . . . . . . . . . . . . . . . . . . . . . 311<br />
N9303536 . . . . . . . . . . . . . . . . . . . . . . . . . . 311<br />
N9303537 . . . . . . . . . . . . . . . . . . . . . . . . . . 311<br />
N9303538 . . . . . . . . . . . . . . . . . . . . . . . . . . 311<br />
N9303539 . . . . . . . . . . . . . . . . . . . . . . . . . . 311<br />
N9303540 . . . . . . . . . . . . . . . . . . . . . . . . . . 311<br />
N9303541 . . . . . . . . . . . . . . . . . . . . . . . . . . 311<br />
N9303542 . . . . . . . . . . . . . . . . . . . . . . . . . . 311<br />
N9303543 . . . . . . . . . . . . . . . . . . . . . . . . . . 311<br />
N9303544 . . . . . . . . . . . . . . . . . . . . . . . . . . 311<br />
N9303545 . . . . . . . . . . . . . . . . . . . . . . . . . . 311<br />
N9303546 . . . . . . . . . . . . . . . . . . . . . . . . . . 311<br />
N9303547 . . . . . . . . . . . . . . . . . . . . . . . . . . 311<br />
N9303548 . . . . . . . . . . . . . . . . . . . . . . . . . . 311<br />
N9303549 . . . . . . . . . . . . . . . . . . . . . . . . . . 311<br />
N9303550 . . . . . . . . . . . . . . . . . . . . . . . . . . 311<br />
N9303551 . . . . . . . . . . . . . . . . . . . . . . . . . . 311<br />
N9303552 . . . . . . . . . . . . . . . . . . . . . . . . . . 311<br />
N9303553 . . . . . . . . . . . . . . . . . . . . . . . . . . 311<br />
N9303554 . . . . . . . . . . . . . . . . . . . . . . . . . . 311<br />
N9303556 . . . . . . . . . . . . . . . . . . . . . . . . . . 311<br />
N9303557 . . . . . . . . . . . . . . . . . . . . . . . . . . 311<br />
N9303558 . . . . . . . . . . . . . . . . . . . . . . . . . . 311<br />
N9303559 . . . . . . . . . . . . . . . . . . . . . . . . . . 311<br />
N9303560 . . . . . . . . . . . . . . . . . . . . . . . . . . 311<br />
N9303561 . . . . . . . . . . . . . . . . . . . . . . . . . . 311<br />
N9303562 . . . . . . . . . . . . . . . . . . . . . . . . . . 311<br />
N9303563 . . . . . . . . . . . . . . . . . . . . . . . . . . 311<br />
N9303564 . . . . . . . . . . . . . . . . . . . . . . . . . . 311<br />
N9303565 . . . . . . . . . . . . . . . . . . . . . . . . . . 311<br />
N9303566 . . . . . . . . . . . . . . . . . . . . . . . . . . 311<br />
N9303567 . . . . . . . . . . . . . . . . . . . . . . . . . . 311<br />
N9303568 . . . . . . . . . . . . . . . . . . . . . . . . . . 311<br />
N9303569 . . . . . . . . . . . . . . . . . . . . . . . . . . 312<br />
N9303570 . . . . . . . . . . . . . . . . . . . . . . . . . . 312<br />
N9303571 . . . . . . . . . . . . . . . . . . . . . . . . . . 312<br />
N9303572 . . . . . . . . . . . . . . . . . . . . . . . . . . 312<br />
N9303573 . . . . . . . . . . . . . . . . . . . . . . . . . . 312<br />
N9303574 . . . . . . . . . . . . . . . . . . . . . . . . . . 312<br />
N9303575 . . . . . . . . . . . . . . . . . . . . . . . . . . 312<br />
N9303576 . . . . . . . . . . . . . . . . . . . . . . . . . . 312<br />
N9303577 . . . . . . . . . . . . . . . . . . . . . . . . . . 312<br />
N9303578 . . . . . . . . . . . . . . . . . . . . . . . . . . 312<br />
N9303579 . . . . . . . . . . . . . . . . . . . . . . . . . . 312<br />
N9303580 . . . . . . . . . . . . . . . . . . . . . . . . . . 312<br />
N9303581 . . . . . . . . . . . . . . . . . . . . . . . . . . 312<br />
N9303582 . . . . . . . . . . . . . . . . . . . . . . . . . . 312<br />
N9303583 . . . . . . . . . . . . . . . . . . . . . . . . . . 312<br />
N9303584 . . . . . . . . . . . . . . . . . . . . . . . . . . 312<br />
N9303585 . . . . . . . . . . . . . . . . . . . . . . . . . . 312<br />
N9303586 . . . . . . . . . . . . . . . . . . . . . . . . . . 312<br />
N9303587 . . . . . . . . . . . . . . . . . . . . . . . . . . 312<br />
N9303588 . . . . . . . . . . . . . . . . . . . . . . . . . . 312<br />
N9303589 . . . . . . . . . . . . . . . . . . . . . . . . . . 312<br />
N9303590 . . . . . . . . . . . . . . . . . . . . . . . . . . 312<br />
N9303591 . . . . . . . . . . . . . . . . . . . . . . . . . . 312<br />
N9303592 . . . . . . . . . . . . . . . . . . . . . . . . . . 312<br />
N9303593 . . . . . . . . . . . . . . . . . . . . . . . . . . 312<br />
N9303594 . . . . . . . . . . . . . . . . . . . . . . . . . . 312<br />
N9303595 . . . . . . . . . . . . . . . . . . . . . . . . . . 312<br />
N9303596 . . . . . . . . . . . . . . . . . . . . . . . . . . 312<br />
N9303597 . . . . . . . . . . . . . . . . . . . . . . . . . . 312<br />
N9303598 . . . . . . . . . . . . . . . . . . . . . . . . . . 312<br />
N9303599 . . . . . . . . . . . . . . . . . . . . . . . . . . 312<br />
N9303600 . . . . . . . . . . . . . . . . . . . . . . . . . . 312<br />
N9303601 . . . . . . . . . . . . . . . . . . . . . . . . . . 312<br />
N9303602 . . . . . . . . . . . . . . . . . . . . . . . . . . 312<br />
N9303603 . . . . . . . . . . . . . . . . . . . . . . . . . . 312<br />
N9303604 . . . . . . . . . . . . . . . . . . . . . . . . . . 312<br />
N9303605 . . . . . . . . . . . . . . . . . . . . . . . . . . 312<br />
N9303606 . . . . . . . . . . . . . . . . . . . . . . . . . . 312<br />
N9303607 . . . . . . . . . . . . . . . . . . . . . . . . . . 312<br />
N9303608 . . . . . . . . . . . . . . . . . . . . . . . . . . 310<br />
N9303609 . . . . . . . . . . . . . . . . . . . . . . . . . . 310<br />
N9303610 . . . . . . . . . . . . . . . . . . . . . . . . . . 310<br />
N9303611 . . . . . . . . . . . . . . . . . . . . . . . . . . 310<br />
N9303612 . . . . . . . . . . . . . . . . . . . . . . . . . . 310<br />
N9303613 . . . . . . . . . . . . . . . . . . . . . . . . . . 310<br />
N9303614 . . . . . . . . . . . . . . . . . . . . . . . . . . 310<br />
N9303615 . . . . . . . . . . . . . . . . . . . . . . . . . . 310<br />
N9303616 . . . . . . . . . . . . . . . . . . . . . . . . . . 310<br />
N9303617 . . . . . . . . . . . . . . . . . . . . . . . . . . 310<br />
N9303618 . . . . . . . . . . . . . . . . . . . . . . . . . . 310<br />
N9303619 . . . . . . . . . . . . . . . . . . . . . . . . . . 310<br />
N9303620 . . . . . . . . . . . . . . . . . . . . . . . . . . 310<br />
N9303621 . . . . . . . . . . . . . . . . . . . . . . . . . . 310<br />
N9303622 . . . . . . . . . . . . . . . . . . . . . . . . . . 310<br />
N9303623 . . . . . . . . . . . . . . . . . . . . . . . . . . 310<br />
N9303624 . . . . . . . . . . . . . . . . . . . . . . . . . . 310<br />
N9303625 . . . . . . . . . . . . . . . . . . . . . . . . . . 310<br />
N9303626 . . . . . . . . . . . . . . . . . . . . . . . . . . 310<br />
N9303627 . . . . . . . . . . . . . . . . . . . . . . . . . . 310<br />
N9303628 . . . . . . . . . . . . . . . . . . . . . . . . . . 310<br />
N9303629 . . . . . . . . . . . . . . . . . . . . . . . . . . 310<br />
N9303630 . . . . . . . . . . . . . . . . . . . . . . . . . . 310<br />
N9303631 . . . . . . . . . . . . . . . . . . . . . . . . . . 310<br />
N9303632 . . . . . . . . . . . . . . . . . . . . . . . . . . 310<br />
N9303633 . . . . . . . . . . . . . . . . . . . . . . . . . . 310<br />
N9303634 . . . . . . . . . . . . . . . . . . . . . . . . . . 310<br />
N9303635 . . . . . . . . . . . . . . . . . . . . . . . . . . 310<br />
N9303636 . . . . . . . . . . . . . . . . . . . . . . . . . . 310<br />
N9303637 . . . . . . . . . . . . . . . . . . . . . . . . . . 310<br />
N9303638 . . . . . . . . . . . . . . . . . . . . . . . . . . 310<br />
N9303639 . . . . . . . . . . . . . . . . . . . . . . . . . . 310<br />
N9303640 . . . . . . . . . . . . . . . . . . . . . . . . . . 310<br />
N9303641 . . . . . . . . . . . . . . . . . . . . . . . . . . 310<br />
N9303641 . . . . . . . . . . . . . . . . . . . . . . . . . . 310<br />
N9303642 . . . . . . . . . . . . . . . . . . . . . . . . . . 310<br />
N9303643 . . . . . . . . . . . . . . . . . . . . . . . . . . 310<br />
Part No. Page Part No. Page Part No. Page
N9303644 – N9316016 Part Number Index<br />
Index<br />
Part Number<br />
425<br />
N9303644 . . . . . . . . . . . . . . . . . . . . . . . . . . 310<br />
N9303645 . . . . . . . . . . . . . . . . . . . . . . . . . . 310<br />
N9303646 . . . . . . . . . . . . . . . . . . . . . . . . . . 309<br />
N9303647 . . . . . . . . . . . . . . . . . . . . . . . . . . 309<br />
N9303648 . . . . . . . . . . . . . . . . . . . . . . . . . . 309<br />
N9303649 . . . . . . . . . . . . . . . . . . . . . . . . . . 309<br />
N9303650 . . . . . . . . . . . . . . . . . . . . . . . . . . 309<br />
N9303651 . . . . . . . . . . . . . . . . . . . . . . . . . . 309<br />
N9303652 . . . . . . . . . . . . . . . . . . . . . . . . . . 309<br />
N9303653 . . . . . . . . . . . . . . . . . . . . . . . . . . 309<br />
N9303654 . . . . . . . . . . . . . . . . . . . . . . . . . . 309<br />
N9303655 . . . . . . . . . . . . . . . . . . . . . . . . . . 309<br />
N9303656 . . . . . . . . . . . . . . . . . . . . . . . . . . 309<br />
N9303657 . . . . . . . . . . . . . . . . . . . . . . . . . . 309<br />
N9303658 . . . . . . . . . . . . . . . . . . . . . . . . . . 309<br />
N9303659 . . . . . . . . . . . . . . . . . . . . . . . . . . 309<br />
N9303660 . . . . . . . . . . . . . . . . . . . . . . . . . . 309<br />
N9303661 . . . . . . . . . . . . . . . . . . . . . . . . . . 309<br />
N9303662 . . . . . . . . . . . . . . . . . . . . . . . . . . 309<br />
N9303663 . . . . . . . . . . . . . . . . . . . . . . . . . . 309<br />
N9303664 . . . . . . . . . . . . . . . . . . . . . . . . . . 309<br />
N9303665 . . . . . . . . . . . . . . . . . . . . . . . . . . 309<br />
N9303666 . . . . . . . . . . . . . . . . . . . . . . . . . . 313<br />
N9303667 . . . . . . . . . . . . . . . . . . . . . . . . . . 313<br />
N9303668 . . . . . . . . . . . . . . . . . . . . . . . . . . 313<br />
N9303669 . . . . . . . . . . . . . . . . . . . . . . . . . . 313<br />
N9303670 . . . . . . . . . . . . . . . . . . . . . . . . . . 313<br />
N9303671 . . . . . . . . . . . . . . . . . . . . . . . . . . 313<br />
N9303672 . . . . . . . . . . . . . . . . . . . . . . . . . . 313<br />
N9303673 . . . . . . . . . . . . . . . . . . . . . . . . . . 313<br />
N9303674 . . . . . . . . . . . . . . . . . . . . . . . . . . 313<br />
N9303675 . . . . . . . . . . . . . . . . . . . . . . . . . . 313<br />
N9303676 . . . . . . . . . . . . . . . . . . . . . . . . . . 313<br />
N9303677 . . . . . . . . . . . . . . . . . . . . . . . . . . 313<br />
N9303678 . . . . . . . . . . . . . . . . . . . . . . . . . . 313<br />
N9303679 . . . . . . . . . . . . . . . . . . . . . . . . . . 313<br />
N9303680 . . . . . . . . . . . . . . . . . . . . . . . . . . 313<br />
N9303681 . . . . . . . . . . . . . . . . . . . . . . . . . . 313<br />
N9303682 . . . . . . . . . . . . . . . . . . . . . . . . . . 313<br />
N9303683 . . . . . . . . . . . . . . . . . . . . . . . . . . 313<br />
N9303684 . . . . . . . . . . . . . . . . . . . . . . . . . . 313<br />
N9303685 . . . . . . . . . . . . . . . . . . . . . . . . . . 313<br />
N9303686 . . . . . . . . . . . . . . . . . . . . . . . . . . 313<br />
N9303687 . . . . . . . . . . . . . . . . . . . . . . . . . . 313<br />
N9303688 . . . . . . . . . . . . . . . . . . . . . . . . . . 313<br />
N9303689 . . . . . . . . . . . . . . . . . . . . . . . . . . 313<br />
N9303690 . . . . . . . . . . . . . . . . . . . . . . . . . . 313<br />
N9303691 . . . . . . . . . . . . . . . . . . . . . . . . . . 313<br />
N9303692 . . . . . . . . . . . . . . . . . . . . . . . . . . 313<br />
N9303693 . . . . . . . . . . . . . . . . . . . . . . . . . . 313<br />
N9303694 . . . . . . . . . . . . . . . . . . . . . . . . . . 313<br />
N9303695 . . . . . . . . . . . . . . . . . . . . . . . . . . 313<br />
N9303696 . . . . . . . . . . . . . . . . . . . . . . . . . . 313<br />
N9303697 . . . . . . . . . . . . . . . . . . . . . . . . . . 313<br />
N9303698 . . . . . . . . . . . . . . . . . . . . . . . . . . 313<br />
N9303699 . . . . . . . . . . . . . . . . . . . . . . . . . . 313<br />
N9303700 . . . . . . . . . . . . . . . . . . . . . . . . . . 313<br />
N9303701 . . . . . . . . . . . . . . . . . . . . . . . . . . 313<br />
N9303702 . . . . . . . . . . . . . . . . . . . . . . . . . . 313<br />
N9303703 . . . . . . . . . . . . . . . . . . . . . . . . . . 313<br />
N9303704 . . . . . . . . . . . . . . . . . . . . . . . . . . 313<br />
N9303705 . . . . . . . . . . . . . . . . . . . . . . . . . . 313<br />
N9303706 . . . . . . . . . . . . . . . . . . . . . . . . . . 313<br />
N9303707 . . . . . . . . . . . . . . . . . . . . . . . . . . 313<br />
N9303708 . . . . . . . . . . . . . . . . . . . . . . . . . . 313<br />
N9303709 . . . . . . . . . . . . . . . . . . . . . . . . . . 313<br />
N9303710 . . . . . . . . . . . . . . . . . . . . . . . . . . 313<br />
N9303711 . . . . . . . . . . . . . . . . . . . . . . . . . . 313<br />
N9303712 . . . . . . . . . . . . . . . . . . . . . . . . . . 313<br />
N9303713 . . . . . . . . . . . . . . . . . . . . . . . . . . 313<br />
N9303714 . . . . . . . . . . . . . . . . . . . . . . . . . . 313<br />
N9303715 . . . . . . . . . . . . . . . . . . . . . . . . . . 313<br />
N9303716 . . . . . . . . . . . . . . . . . . . . . . . . . . 313<br />
N9303717 . . . . . . . . . . . . . . . . . . . . . . . . . . 313<br />
N9303718 . . . . . . . . . . . . . . . . . . . . . . . . . . 311<br />
N9303719 . . . . . . . . . . . . . . . . . . . . . . . . . . 311<br />
N9303720 . . . . . . . . . . . . . . . . . . . . . . . . . . 311<br />
N9303721 . . . . . . . . . . . . . . . . . . . . . . . . . . 311<br />
N9303722 . . . . . . . . . . . . . . . . . . . . . . . . . . 313<br />
N9303723 . . . . . . . . . . . . . . . . . . . . . . . . . . 313<br />
N9303759 . . . . . . . . . . . . . . . . . . . . . . . . . . . 68<br />
N9303761 . . . . . . . . . . . . . . . . . . . . . . . . . . . 68<br />
N9303763 . . . . . . . . . . . . . . . . . . . . . . . . . . . 68<br />
N9303766 . . . . . . . . . . . . . . . . . . . . . . . . . . . 68<br />
N9303771 . . . . . . . . . . . . . . . . . . . . . . . . . . . 68<br />
N9303775 . . . . . . . . . . . . . . . . . . . . . . . . . . . 68<br />
N9303779 . . . . . . . . . . . . . . . . . . . . . . . . . . . 69<br />
N9303783 . . . . . . . . . . . . . . . . . . . . . . . . . . . 68<br />
N9303784 . . . . . . . . . . . . . . . . . . . . . . . . . . . 69<br />
N9303785 . . . . . . . . . . . . . . . . . . . . . . . . . . . 69<br />
N9303788 . . . . . . . . . . . . . . . . . . . . . . . . . . . 69<br />
N9303789 . . . . . . . . . . . . . . . . . . . . . . . . . . . 69<br />
N9303799 . . . . . . . . . . . . . . . . . . . . . . . . . . . 69<br />
N9303801 . . . . . . . . . . . . . . . . . . . . . . . . . . . 69<br />
N9303806 . . . . . . . . . . . . . . . . . . . . . . . . . . . 69<br />
N9303810 . . . . . . . . . . . . . . . . . . . . . . . . . . . 69<br />
N9303812 . . . . . . . . . . . . . . . . . . . . . . . . . . . 69<br />
N9304012 . . . . . . . . . . . . . . . . . . . . . . . . . . 130<br />
N9304013 . . . . . . . . . . . . . . . . . . . . . . . . . . 130<br />
N9304014 . . . . . . . . . . . . . . . . . . . . . . . . . . 130<br />
N9304016 . . . . . . . . . . . . . . . . . . . . . . . . . . 130<br />
N9304017 . . . . . . . . . . . . . . . . . . . . . . . . . . 130<br />
N9304018 . . . . . . . . . . . . . . . . . . . . . . . . . . 130<br />
N9304019 . . . . . . . . . . . . . . . . . . . . . . . . . . 130<br />
N9304020 . . . . . . . . . . . . . . . . . . . . . . . . . . 130<br />
N9304021 . . . . . . . . . . . . . . . . . . . . . . . . . . 130<br />
N9304022 . . . . . . . . . . . . . . . . . . . . . . . . . . 130<br />
N9304023 . . . . . . . . . . . . . . . . . . . . . . . . . . 130<br />
N9304046 . . . . . . . . . . . . . . . . . . . . . . . . . . 130<br />
N9304047 . . . . . . . . . . . . . . . . . . . . . . . . . . 130<br />
N9304048 . . . . . . . . . . . . . . . . . . . . . . . . . . 130<br />
N9305012 . . . . . . . . . . . . . . . . . . . . . . . . . . 130<br />
N9305013 . . . . . . . . . . . . . . . . . . . . . . . . . . 130<br />
N9305014 . . . . . . . . . . . . . . . . . . . . . . . . . . 130<br />
N9305016 . . . . . . . . . . . . . . . . . . . . . . . . . . 130<br />
N9305017 . . . . . . . . . . . . . . . . . . . . . . . . . . 130<br />
N9305018 . . . . . . . . . . . . . . . . . . . . . . . . . . 130<br />
N9305019 . . . . . . . . . . . . . . . . . . . . . . . . . . 130<br />
N9305022 . . . . . . . . . . . . . . . . . . . . . . . . . . 130<br />
N9305047 . . . . . . . . . . . . . . . . . . . . . . . . . . 130<br />
N9305048 . . . . . . . . . . . . . . . . . . . . . . . . . . 130<br />
N9306000 . . . . . . . . . . . . . . . . . . . . . . . . . . . 94<br />
N9306001 . . . . . . . . . . . . . . . . . . . . . . . . . . . 94<br />
N9306002 . . . . . . . . . . . . . . . . . . . . . . . . . . 164<br />
N9306003 . . . . . . . . . . . . . . . . . . . . . . . . . . 164<br />
N9306004 . . . . . . . . . . . . . . . . . . . . . . . . . . 164<br />
N9306005 . . . . . . . . . . . . . . . . . . . . . . . . . . 164<br />
N9306006 . . . . . . . . . . . . . . . . . . . . . . . . . . 164<br />
N9306014 . . . . . . . . . . . . . . . . . . . . . . . . . . 164<br />
N9306015 . . . . . . . . . . . . . . . . . . . . . . . 89, 271<br />
N9306016 . . . . . . . . . . . . . . . . . . . . . . . . . . . 23<br />
N9306017 . . . . . . . . . . . . . . . . . . . . . . . . . . 324<br />
N9306019 . . . . . . . . . . . . . . . . . . . . . . . . . . 324<br />
N9306020 . . . . . . . . . . . . . . . . . . . . . . . . . . 324<br />
N9306021 . . . . . . . . . . . . . . . . . . . . . . . . . . 324<br />
N9306022 . . . . . . . . . . . . . . . . . . . . . . . . . . 326<br />
N9306023 . . . . . . . . . . . . . . . . . . . . . . . . . . 326<br />
N9306024 . . . . . . . . . . . . . . . . . . . . . . . . . . 326<br />
N9306025 . . . . . . . . . . . . . . . . . . . . . . . . . . 326<br />
N9306026 . . . . . . . . . . . . . . . . . . . . . . . . . . 326<br />
N9306027 . . . . . . . . . . . . . . . . . . . . . . . . . . 326<br />
N9306028 . . . . . . . . . . . . . . . . . . . . . . . . . . 326<br />
N9306029 . . . . . . . . . . . . . . . . . . . . . . . . . . 326<br />
N9306030 . . . . . . . . . . . . . . . . . . . . . . . . . . 326<br />
N9306031 . . . . . . . . . . . . . . . . . . . . . . . . . . 326<br />
N9306032 . . . . . . . . . . . . . . . . . . . . . . . . . . 326<br />
N9306033 . . . . . . . . . . . . . . . . . . . . . . . . . . 326<br />
N9306034 . . . . . . . . . . . . . . . . . . . . . . . . . . 326<br />
N9306035 . . . . . . . . . . . . . . . . . . . . . . . . . . 326<br />
N9306036 . . . . . . . . . . . . . . . . . . . . . . . . . . 326<br />
N9306037 . . . . . . . . . . . . . . . . . . . . . . . . . . 326<br />
N9306038 . . . . . . . . . . . . . . . . . . . . . . . . . . 326<br />
N9306039 . . . . . . . . . . . . . . . . . . . . . . . . . . 326<br />
N9306040 . . . . . . . . . . . . . . . . . . . . . . . . . . 326<br />
N9306041 . . . . . . . . . . . . . . . . . . . . . . . . . . 326<br />
N9306042 . . . . . . . . . . . . . . . . . . . . . . . . . . 326<br />
N9306044 . . . . . . . . . . . . . . . . . . . . . . . . . . 325<br />
N9306045 . . . . . . . . . . . . . . . . . . . . . . . . . . 325<br />
N9306046 . . . . . . . . . . . . . . . . . . . . . . . . . . 325<br />
N9306047 . . . . . . . . . . . . . . . . . . . . . . . . . . 325<br />
N9306048 . . . . . . . . . . . . . . . . . . . . . . . . . . 164<br />
N9306050 . . . . . . . . . . . . . . . . . . . . . . . . . . 164<br />
N9306051 . . . . . . . . . . . . . . . . . . . . . . . . . . 164<br />
N9306052 . . . . . . . . . . . . . . . . . . . . . . . . . . 271<br />
N9306053 . . . . . . . . . . . . . . . . . . . . . . . . . . 271<br />
N9306057 . . . . . . . . . . . . . . . . . . . . . . . . . . 271<br />
N9306058 . . . . . . . . . . . . . . . . . . . . . . . . . . 165<br />
N9306059 . . . . . . . . . . . . . . . . . . . . . . . . . . 165<br />
N9306060 . . . . . . . . . . . . . . . . . . . . . . . . . . 165<br />
N9306061 . . . . . . . . . . . . . . . . . . . . . . . . . . 165<br />
N9306064 . . . . . . . . . . . . . . . . . . . . . . . . . . 165<br />
N9306065 . . . . . . . . . . . . . . . . . . . . . . . . . . 165<br />
N9306066 . . . . . . . . . . . . . . . . . . . . . . . . . . 165<br />
N9306080 . . . . . . . . . . . . . . . . . . . . . . . . . . 271<br />
N9306090 . . . . . . . . . . . . . . . . . . . . . . . . . . . 94<br />
N9306091 . . . . . . . . . . . . . . . . . . . . . . . . . . . 94<br />
N9306092 . . . . . . . . . . . . . . . . . . . . . . . . . . . 94<br />
N9306093 . . . . . . . . . . . . . . . . . . . . . . . . . . . 94<br />
N9306094 . . . . . . . . . . . . . . . . . . . . . . . . . . . 94<br />
N9306095 . . . . . . . . . . . . . . . . . . . . . . . . . . . 94<br />
N9306096 . . . . . . . . . . . . . . . . . . . . . . . . . . . 94<br />
N9307000 . . . . . . . . . . . . . . . . . . . . . . . . . . 181<br />
N9307001 . . . . . . . . . . . . . . . . . . . . . . . . . . 181<br />
N9307002 . . . . . . . . . . . . . . . . . . . . . . . . . . 181<br />
N9307003 . . . . . . . . . . . . . . . . . . . . . . . . . . 181<br />
N9307004 . . . . . . . . . . . . . . . . . . . . . . . . . . 181<br />
N9307005 . . . . . . . . . . . . . . . . . . . . . . . . . . 181<br />
N9307006 . . . . . . . . . . . . . . . . . . . . . . . . . . 181<br />
N9307007 . . . . . . . . . . . . . . . . . . . . . . . . . . 181<br />
N9307008 . . . . . . . . . . . . . . . . . . . . . . . . . . 181<br />
N9307009 . . . . . . . . . . . . . . . . . . . . . . . . . . 181<br />
N9307010 . . . . . . . . . . . . . . . . . . . . . . . . . . 181<br />
N9307011 . . . . . . . . . . . . . . . . . . . . . . . . . . 181<br />
N9307012 . . . . . . . . . . . . . . . . . . . . . . . . . . 181<br />
N9307013 . . . . . . . . . . . . . . . . . . . . . . . . . . 181<br />
N9307027 . . . . . . . . . . . . . . . . . . . . . . . . . . 271<br />
N9307029 . . . . . . . . . . . . . . . . . . . . . . . . . . 167<br />
N9307037 . . . . . . . . . . . . . . . . . . . . . . . . . . 181<br />
N9307038 . . . . . . . . . . . . . . . . . . . . . . . . . . 181<br />
N9316000 . . . . . . . . . . . . . . . . . . . . . . . . . . 180<br />
N9316001 . . . . . . . . . . . . . . . . . . . . . . . . . . 121<br />
N9316002 . . . . . . . . . . . . . . . . . . . . . . . . . . 121<br />
N9316003 . . . . . . . . . . . . . . . . . . . . . . . . . . 121<br />
N9316004 . . . . . . . . . . . . . . . . . . . . . . . . . . 121<br />
N9316005 . . . . . . . . . . . . . . . . . . . . . . . . . . 121<br />
N9316006 . . . . . . . . . . . . . . . . . . . . . . . . . . 121<br />
N9316007 . . . . . . . . . . . . . . . . . . . . . . . . . . 121<br />
N9316008 . . . . . . . . . . . . . . . . . . . . . . . . . . 121<br />
N9316009 . . . . . . . . . . . . . . . . . . . . . . . . . . 121<br />
N9316010 . . . . . . . . . . . . . . . . . . . . . . . . . . 121<br />
N9316011 . . . . . . . . . . . . . . . . . . . . . . . . . . 121<br />
N9316012 . . . . . . . . . . . . . . . . . . . . . . . . . . 121<br />
N9316013 . . . . . . . . . . . . . . . . . . . . . . . . . . 121<br />
N9316014 . . . . . . . . . . . . . . . . . . . . . . . . . . 121<br />
N9316015 . . . . . . . . . . . . . . . . . . . . . . 121, 127<br />
N9316016 . . . . . . . . . . . . . . . . . . . . . . . . . . 121<br />
Part No. Page Part No. Page Part No. Page<br />
See page 4 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
See page 2 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong>
Index Part Number N9316017 – N9316257<br />
Index<br />
Part Number<br />
426<br />
N9316017 . . . . . . . . . . . . . . . . . . . . . . . . . . 121<br />
N9316018 . . . . . . . . . . . . . . . . . . . . . . . . . . 121<br />
N9316019 . . . . . . . . . . . . . . . . . . . . . . . . . . 121<br />
N9316020 . . . . . . . . . . . . . . . . . . . . . . . . . . 121<br />
N9316021 . . . . . . . . . . . . . . . . . . . . . . . . . . 121<br />
N9316022 . . . . . . . . . . . . . . . . . . . . . . . . . . 121<br />
N9316023 . . . . . . . . . . . . . . . . . . . . . . . 97, 121<br />
N9316024 . . . . . . . . . . . . . . . . . . . . 97-98, 121<br />
N9316025 . . . . . . . . . . . . . . . . . . . . . . . . . . 121<br />
N9316026 . . . . . . . . . . . . . . . . . . . . . . . . . . 121<br />
N9316027 . . . . . . . . . . . . . . . . . . . . . . . . . . 121<br />
N9316028 . . . . . . . . . . . . . . . . . . . . . . . . . . 121<br />
N9316029 . . . . . . . . . . . . . . . . . . . . . . . . . . 121<br />
N9316030 . . . . . . . . . . . . . . . . . . . . . . . . . . 121<br />
N9316031 . . . . . . . . . . . . . . . . . . . . . . . . . . 121<br />
N9316032 . . . . . . . . . . . . . . . . . . . . . . . . . . 121<br />
N9316033 . . . . . . . . . . . . . . . . . . . . . . . . . . 121<br />
N9316034 . . . . . . . . . . . . . . . . . . . . . . . . . . 121<br />
N9316035 . . . . . . . . . . . . . . . . . . . . . . . . . . 121<br />
N9316036 . . . . . . . . . . . . . . . . . . . . . . . . . . 121<br />
N9316037 . . . . . . . . . . . . . . . . . . . . . . . . . . 121<br />
N9316038 . . . . . . . . . . . . . . . . . . . . . . . . . . 121<br />
N9316039 . . . . . . . . . . . . . . . . . . . . . . . . . . 121<br />
N9316040 . . . . . . . . . . . . . . . . . . . . . . . . . . 121<br />
N9316041 . . . . . . . . . . . . . . . . . . . . . . . . . . 121<br />
N9316042 . . . . . . . . . . . . . . . . . . . . . . . . . . 121<br />
N9316043 . . . . . . . . . . . . . . . . . . . . . . . . . . 121<br />
N9316044 . . . . . . . . . . . . . . . . . . . . . . . . . . 121<br />
N9316045 . . . . . . . . . . . . . . . . . . . . . . . . . . 121<br />
N9316046 . . . . . . . . . . . . . . . . . . . . 97-98, 121<br />
N9316047 . . . . . . . . . . . . . . . . . . . . . . . . . . 121<br />
N9316048 . . . . . . . . . . . . . . . . . . . . . . . . . . 121<br />
N9316049 . . . . . . . . . . . . . . . . . . . . . . . . . . 121<br />
N9316050 . . . . . . . . . . . . . . . . . . . . 97-98, 121<br />
N9316051 . . . . . . . . . . . . . . . . . . . . . . . . . . 121<br />
N9316052 . . . . . . . . . . . . . . . . . . . . . . . . . . 121<br />
N9316053 . . . . . . . . . . . . . . . . . . . . . . . . . . 121<br />
N9316054 . . . . . . . . . . . . . . . . . . . . . . . . . . 121<br />
N9316056 . . . . . . . . . . . . . . . . . . . . . . . . . . 121<br />
N9316057 . . . . . . . . . . . . . . . . . . . . . . . . . . 121<br />
N9316058 . . . . . . . . . . . . . . . . . . . . . . . . . . 121<br />
N9316061 . . . . . . . . . . . . . . . . . . . . . . . . . . 121<br />
N9316062 . . . . . . . . . . . . . . . . . . . . . . . . . . 121<br />
N9316063 . . . . . . . . . . . . . . . . . . . . . . . . . . 121<br />
N9316064 . . . . . . . . . . . . . . . . . . . . . . . . . . 121<br />
N9316065 . . . . . . . . . . . . . . . . . . . . . . . . . . 127<br />
N9316066 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />
N9316067 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />
N9316068 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />
N9316069 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />
N9316071 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />
N9316072 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />
N9316073 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />
N9316074 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />
N9316075 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />
N9316076 . . . . . . . . . . . . . . . . . . . . 97-98, 122<br />
N9316077 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />
N9316078 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />
N9316079 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />
N9316080 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />
N9316081 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />
N9316082 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />
N9316083 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />
N9316084 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />
N9316085 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />
N9316086 . . . . . . . . . . . . . . . . . . . . 97-98, 122<br />
N9316087 . . . . . . . . . . . . . . . . . . . . 97-98, 122<br />
N9316088 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />
N9316089 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />
N9316090 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />
N9316091 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />
N9316092 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />
N9316093 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />
N9316094 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />
N9316095 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />
N9316096 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />
N9316097 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />
N9316098 . . . . . . . . . . . . . . . . . . . . 97-98, 122<br />
N9316099 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />
N9316100 . . . . . . . . . . . . . . . . . . . . 97-98, 122<br />
N9316101 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />
N9316102 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />
N9316103 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />
N9316104 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />
N9316105 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />
N9316108 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />
N9316109 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />
N9316110 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />
N9316111 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />
N9316112 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />
N9316113 . . . . . . . . . . . . . . . . . . . . . . . . . . 123<br />
N9316114 . . . . . . . . . . . . . . . . . . . . . . . . . . 123<br />
N9316115 . . . . . . . . . . . . . . . . . . . . . . . . . . 123<br />
N9316116 . . . . . . . . . . . . . . . . . . . . . . . . . . 123<br />
N9316117 . . . . . . . . . . . . . . . . . . . . . . . . . . 123<br />
N9316118 . . . . . . . . . . . . . . . . . . . . . . . . . . 123<br />
N9316119 . . . . . . . . . . . . . . . . . . . . . . . . . . 123<br />
N9316120 . . . . . . . . . . . . . . . . . . . . . . . . . . 123<br />
N9316121 . . . . . . . . . . . . . . . . . . . . . . . . . . 123<br />
N9316122 . . . . . . . . . . . . . . . . . . . . . . . . . . 123<br />
N9316123 . . . . . . . . . . . . . . . . . . . . . . . . . . 123<br />
N9316124 . . . . . . . . . . . . . . . . . . . . . . . . . . 123<br />
N9316125 . . . . . . . . . . . . . . . . . . . . . . . . . . 123<br />
N9316126 . . . . . . . . . . . . . . . . . . . . . . . . . . 123<br />
N9316127 . . . . . . . . . . . . . . . . . . . . . . . . . . 123<br />
N9316128 . . . . . . . . . . . . . . . . . . . . . . . . . . 123<br />
N9316129 . . . . . . . . . . . . . . . . . . . . . . . 97, 123<br />
N9316130 . . . . . . . . . . . . . . . . . . . . . . . . . . 123<br />
N9316131 . . . . . . . . . . . . . . . . . . . . . . . . . . 123<br />
N9316132 . . . . . . . . . . . . . . . . . . . . . . . . . . 123<br />
N9316133 . . . . . . . . . . . . . . . . . . . . . . . . . . 123<br />
N9316134 . . . . . . . . . . . . . . . . . . . . . . . . . . 123<br />
N9316135 . . . . . . . . . . . . . . . . . . . . . . . . . . 123<br />
N9316136 . . . . . . . . . . . . . . . . . . . . . . . 97, 123<br />
N9316137 . . . . . . . . . . . . . . . . . . . . . . . . . . 123<br />
N9316138 . . . . . . . . . . . . . . . . . . . . . . . . . . 123<br />
N9316139 . . . . . . . . . . . . . . . . . . . . . . . . . . 123<br />
N9316140 . . . . . . . . . . . . . . . . . . . . . . . . . . 123<br />
N9316141 . . . . . . . . . . . . . . . . . . . . . . . . . . 123<br />
N9316142 . . . . . . . . . . . . . . . . . . . . . . . . . . 123<br />
N9316143 . . . . . . . . . . . . . . . . . . . . . . . . . . 123<br />
N9316144 . . . . . . . . . . . . . . . . . . . . . . . . . . 123<br />
N9316145 . . . . . . . . . . . . . . . . . . . . . . . . . . 123<br />
N9316146 . . . . . . . . . . . . . . . . . . . . . . . . . . 123<br />
N9316147 . . . . . . . . . . . . . . . . . . . . . . . . . . 123<br />
N9316148 . . . . . . . . . . . . . . . . . . . . . . . . . . 123<br />
N9316149 . . . . . . . . . . . . . . . . . . . . . . . . . . 123<br />
N9316150 . . . . . . . . . . . . . . . . . . . . . . . . . . 123<br />
N9316151 . . . . . . . . . . . . . . . . . . . . . . . . . . 123<br />
N9316152 . . . . . . . . . . . . . . . . . . . . . . . 97, 123<br />
N9316153 . . . . . . . . . . . . . . . . . . . . . . . 98, 123<br />
N9316172 . . . . . . . . . . . . . . . . . . . . . . . . . . 124<br />
N9316173 . . . . . . . . . . . . . . . . . . . . . . . . . . 124<br />
N9316174 . . . . . . . . . . . . . . . . . . . . . . . . . . 124<br />
N9316175 . . . . . . . . . . . . . . . . . . . . . . . . . . 124<br />
N9316176 . . . . . . . . . . . . . . . . . . . . . . . . . . 124<br />
N9316177 . . . . . . . . . . . . . . . . . . . . . . . . . . 124<br />
N9316178 . . . . . . . . . . . . . . . . . . . . . . . . . . 124<br />
N9316179 . . . . . . . . . . . . . . . . . . . . . . . . . . 124<br />
N9316180 . . . . . . . . . . . . . . . . . . . . . . . . . . 124<br />
N9316181 . . . . . . . . . . . . . . . . . . . . . . . . . . 124<br />
N9316182 . . . . . . . . . . . . . . . . . . . . . . . . . . 124<br />
N9316183 . . . . . . . . . . . . . . . . . . . . . . . . . . 124<br />
N9316184 . . . . . . . . . . . . . . . . . . . . . . . . . . 124<br />
N9316185 . . . . . . . . . . . . . . . . . . . . . . . . . . 124<br />
N9316186 . . . . . . . . . . . . . . . . . . . . . . . . . . 124<br />
N9316187 . . . . . . . . . . . . . . . . . . . . . . . . . . 124<br />
N9316188 . . . . . . . . . . . . . . . . . . . . . . . . . . 124<br />
N9316189 . . . . . . . . . . . . . . . . . . . . . . . . . . 124<br />
N9316190 . . . . . . . . . . . . . . . . . . . . . . . 97, 124<br />
N9316191 . . . . . . . . . . . . . . . . . . . . . . . 97, 124<br />
N9316192 . . . . . . . . . . . . . . . . . . . . . . . . . . 124<br />
N9316193 . . . . . . . . . . . . . . . . . . . . . . . . . . 124<br />
N9316194 . . . . . . . . . . . . . . . . . . . . . . . . . . 124<br />
N9316195 . . . . . . . . . . . . . . . . . . . . . . . . . . 124<br />
N9316196 . . . . . . . . . . . . . . . . . . . . . . . . . . 124<br />
N9316197 . . . . . . . . . . . . . . . . . . . . 97-98, 124<br />
N9316198 . . . . . . . . . . . . . . . . . . . . . . . . . . 124<br />
N9316199 . . . . . . . . . . . . . . . . . . . . . . . . . . 124<br />
N9316200 . . . . . . . . . . . . . . . . . . . . . . . . . . 125<br />
N9316201 . . . . . . . . . . . . . . . . . . . . . . . 97, 125<br />
N9316202 . . . . . . . . . . . . . . . . . . . . . . . . . . 125<br />
N9316203 . . . . . . . . . . . . . . . . . . . . . . . . . . 125<br />
N9316204 . . . . . . . . . . . . . . . . . . . . . . . . . . 125<br />
N9316205 . . . . . . . . . . . . . . . . . . . . . . . . . . 125<br />
N9316206 . . . . . . . . . . . . . . . . . . . . . . . 97, 125<br />
N9316207 . . . . . . . . . . . . . . . . . . . . 97-98, 125<br />
N9316208 . . . . . . . . . . . . . . . . . . . . 97-98, 125<br />
N9316209 . . . . . . . . . . . . . . . . . . . . . . . . . . 125<br />
N9316210 . . . . . . . . . . . . . . . . . . . . . . . . . . 125<br />
N9316211 . . . . . . . . . . . . . . . . . . . . . . . . . . 125<br />
N9316212 . . . . . . . . . . . . . . . . . . . . . . . . . . 125<br />
N9316213 . . . . . . . . . . . . . . . . . . . . . . . . . . 125<br />
N9316214 . . . . . . . . . . . . . . . . . . . . . . . . . . 125<br />
N9316215 . . . . . . . . . . . . . . . . . . . . . . . . . . 125<br />
N9316216 . . . . . . . . . . . . . . . . . . . . . . . . . . 125<br />
N9316217 . . . . . . . . . . . . . . . . . . . . . . . . . . 125<br />
N9316218 . . . . . . . . . . . . . . . . . . . . . . . . . . 125<br />
N9316219 . . . . . . . . . . . . . . . . . . . . . . . . . . 125<br />
N9316220 . . . . . . . . . . . . . . . . . . . . . . . . . . 125<br />
N9316221 . . . . . . . . . . . . . . . . . . . . . . . . . . 125<br />
N9316222 . . . . . . . . . . . . . . . . . . . . . . . . . . 125<br />
N9316223 . . . . . . . . . . . . . . . . . . . . . . . . . . 125<br />
N9316224 . . . . . . . . . . . . . . . . . . . . . . . . . . 125<br />
N9316225 . . . . . . . . . . . . . . . . . . . . . . . . . . 125<br />
N9316226 . . . . . . . . . . . . . . . . . . . . . . . . . . 125<br />
N9316227 . . . . . . . . . . . . . . . . . . . . . . . . . . 125<br />
N9316228 . . . . . . . . . . . . . . . . . . . . . . . . . . 125<br />
N9316229 . . . . . . . . . . . . . . . . . . . . . . . . . . 125<br />
N9316230 . . . . . . . . . . . . . . . . . . . . . . . . . . 125<br />
N9316231 . . . . . . . . . . . . . . . . . . . . . . . . . . 125<br />
N9316232 . . . . . . . . . . . . . . . . . . . . . . . . . . 125<br />
N9316234 . . . . . . . . . . . . . . . . . . . . . . . 97, 125<br />
N9316235 . . . . . . . . . . . . . . . . . . . . . . . . . . 125<br />
N9316236 . . . . . . . . . . . . . . . . . . . . . . . . . . 125<br />
N9316237 . . . . . . . . . . . . . . . . . . . . . . . . . . 125<br />
N9316238 . . . . . . . . . . . . . . . . . . . . . . . . . . 125<br />
N9316239 . . . . . . . . . . . . . . . . . . . . . . . . . . 125<br />
N9316240 . . . . . . . . . . . . . . . . . . . . . . . . . . 125<br />
N9316241 . . . . . . . . . . . . . . . . . . . . . . . . . . 125<br />
N9316242 . . . . . . . . . . . . . . . . . . . . . . . . . . 125<br />
N9316243 . . . . . . . . . . . . . . . . . . . . . . . 97, 125<br />
N9316244 . . . . . . . . . . . . . . . . . . . . . . . . . . 125<br />
N9316245 . . . . . . . . . . . . . . . . . . . . . . . . . . 125<br />
N9316246 . . . . . . . . . . . . . . . . . . . . . . . . . . 125<br />
N9316247 . . . . . . . . . . . . . . . . . . . . . . . . . . 125<br />
N9316248 . . . . . . . . . . . . . . . . . . . . . . . . . . 125<br />
N9316249 . . . . . . . . . . . . . . . . . . . . . . . . . . 125<br />
N9316250 . . . . . . . . . . . . . . . . . . . . . . . . . . 125<br />
N9316251 . . . . . . . . . . . . . . . . . . . . . . . . . . 125<br />
N9316252 . . . . . . . . . . . . . . . . . . . . . . . . . . 125<br />
N9316253 . . . . . . . . . . . . . . . . . . . . . . . . . . 125<br />
N9316254 . . . . . . . . . . . . . . . . . . . . . . . . . . 125<br />
N9316255 . . . . . . . . . . . . . . . . . . . . 97-98, 125<br />
N9316256 . . . . . . . . . . . . . . . . . . . . . . . . . . 125<br />
N9316257 . . . . . . . . . . . . . . . . . . . . . . . . . . 125<br />
Part No. Page Part No. Page Part No. Page
N9316258 – N9316627 Part Number Index<br />
Index<br />
Part Number<br />
427<br />
N9316258 . . . . . . . . . . . . . . . . . . . . . . . . . . 125<br />
N9316259 . . . . . . . . . . . . . . . . . . . . . . . . . . 125<br />
N9316260 . . . . . . . . . . . . . . . . . . . . . . . . . . 125<br />
N9316261 . . . . . . . . . . . . . . . . . . . . . . . . . . 127<br />
N9316262 . . . . . . . . . . . . . . . . . . . . . . . . . . 127<br />
N9316263 . . . . . . . . . . . . . . . . . . . . . . . . . . 123<br />
N9316264 . . . . . . . . . . . . . . . . . . . . . . . . . . 123<br />
N9316265 . . . . . . . . . . . . . . . . . . . . . . . . . . 123<br />
N9316266 . . . . . . . . . . . . . . . . . . . . . . . . . . 123<br />
N9316267 . . . . . . . . . . . . . . . . . . . . . . . . . . 123<br />
N9316268 . . . . . . . . . . . . . . . . . . . . . . . . . . 121<br />
N9316269 . . . . . . . . . . . . . . . . . . . . . . . . . . 121<br />
N9316270 . . . . . . . . . . . . . . . . . . . . . . . . . . 121<br />
N9316271 . . . . . . . . . . . . . . . . . . . . . . . . . . 121<br />
N9316272 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />
N9316273 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />
N9316274 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />
N9316275 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />
N9316276 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />
N9316277 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />
N9316278 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />
N9316279 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />
N9316280 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />
N9316281 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />
N9316282 . . . . . . . . . . . . . . . . . . . . . . . 97, 122<br />
N9316283 . . . . . . . . . . . . . . . . . . . . 97-98, 122<br />
N9316284 . . . . . . . . . . . . . . . . . . . . . . . 98, 122<br />
N9316285 . . . . . . . . . . . . . . . . . . . . . . . 97, 122<br />
N9316286 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />
N9316287 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />
N9316288 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />
N9316289 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />
N9316290 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />
N9316291 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />
N9316292 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />
N9316293 . . . . . . . . . . . . . . . . . . . . 97-98, 122<br />
N9316294 . . . . . . . . . . . . . . . . . . . . . . . 98, 122<br />
N9316295 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />
N9316296 . . . . . . . . . . . . . . . . . . . . . . . 97, 122<br />
N9316297 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />
N9316298 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />
N9316299 . . . . . . . . . . . . . . . . . . . . . . . 97, 122<br />
N9316300 . . . . . . . . . . . . . . . . . . . . 97-98, 122<br />
N9316301 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />
N9316302 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />
N9316303 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />
N9316304 . . . . . . . . . . . . . . . . . . . . . . . . . . 129<br />
N9316305 . . . . . . . . . . . . . . . . . . . . . . . . . . 129<br />
N9316319 . . . . . . . . . . . . . . . . . . . . . . . . . . 125<br />
N9316345 . . . . . . . . . . . . . . . . . . . . . . . . . . 127<br />
N9316346 . . . . . . . . . . . . . . . . . . . . . . . . . . 127<br />
N9316347 . . . . . . . . . . . . . . . . . . . . . . . . . . 127<br />
N9316348 . . . . . . . . . . . . . . . . . . . . . . . . . . 127<br />
N9316349 . . . . . . . . . . . . . . . . . . . . . . . . . . 127<br />
N9316350 . . . . . . . . . . . . . . . . . . . . . . . . . . 127<br />
N9316351 . . . . . . . . . . . . . . . . . . . . . . . . . . 127<br />
N9316352 . . . . . . . . . . . . . . . . . . . . . . . . . . 127<br />
N9316353 . . . . . . . . . . . . . . . . . . . . . . . . . . 127<br />
N9316354 . . . . . . . . . . . . . . . . . . . . . . . . . . 127<br />
N9316355 . . . . . . . . . . . . . . . . . . . . . . . . . . 127<br />
N9316356 . . . . . . . . . . . . . . . . . . . . . . . . . . 127<br />
N9316357 . . . . . . . . . . . . . . . . . . . . . . . . . . 127<br />
N9316358 . . . . . . . . . . . . . . . . . . . . . . . . . . 127<br />
N9316359 . . . . . . . . . . . . . . . . . . . . . . . . . . 129<br />
N9316360 . . . . . . . . . . . . . . . . . . . . . . . . . . 129<br />
N9316361 . . . . . . . . . . . . . . . . . . . . . . . . . . 129<br />
N9316386 . . . . . . . . . . . . . . . . . . . . . . . . . . 127<br />
N9316387 . . . . . . . . . . . . . . . . . . . . . . . . . . 127<br />
N9316388 . . . . . . . . . . . . . . . . . . . . . . . 98, 127<br />
N9316389 . . . . . . . . . . . . . . . . . . . . . . . . . . 127<br />
N9316390 . . . . . . . . . . . . . . . . . . . . . . . . . . 127<br />
N9316391 . . . . . . . . . . . . . . . . . . . . . . . . . . 127<br />
N9316392 . . . . . . . . . . . . . . . . . . . . 97-98, 127<br />
N9316393 . . . . . . . . . . . . . . . . . . . . 97-98, 127<br />
N9316394 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />
N9316395 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />
N9316396 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />
N9316398 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />
N9316399 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />
N9316400 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />
N9316401 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />
N9316402 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />
N9316403 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />
N9316404 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />
N9316405 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />
N9316406 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />
N9316407 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />
N9316408 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />
N9316409 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />
N9316410 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />
N9316411 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />
N9316412 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />
N9316413 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />
N9316416 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />
N9316417 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />
N9316418 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />
N9316419 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />
N9316420 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />
N9316421 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />
N9316422 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />
N9316423 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />
N9316425 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />
N9316426 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />
N9316427 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />
N9316428 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />
N9316429 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />
N9316430 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />
N9316431 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />
N9316432 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />
N9316433 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />
N9316434 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />
N9316435 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />
N9316436 . . . . . . . . . . . . . . . . . . . . . . . . . . 123<br />
N9316437 . . . . . . . . . . . . . . . . . . . . . . . . . . 123<br />
N9316438 . . . . . . . . . . . . . . . . . . . . . . . . . . 123<br />
N9316439 . . . . . . . . . . . . . . . . . . . . . . . . . . 123<br />
N9316440 . . . . . . . . . . . . . . . . . . . . . . . . . . 123<br />
N9316441 . . . . . . . . . . . . . . . . . . . . . . . . . . 123<br />
N9316442 . . . . . . . . . . . . . . . . . . . . . . . . . . 123<br />
N9316443 . . . . . . . . . . . . . . . . . . . . . . . . . . 123<br />
N9316444 . . . . . . . . . . . . . . . . . . . . . . . . . . 123<br />
N9316445 . . . . . . . . . . . . . . . . . . . . . . . . . . 123<br />
N9316446 . . . . . . . . . . . . . . . . . . . . . . . . . . 123<br />
N9316478 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />
N9316480 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />
N9316481 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />
N9316482 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />
N9316483 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />
N9316484 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />
N9316485 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />
N9316487 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />
N9316488 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />
N9316489 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />
N9316490 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />
N9316491 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />
N9316492 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />
N9316493 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />
N9316494 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />
N9316495 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />
N9316496 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />
N9316497 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />
N9316498 . . . . . . . . . . . . . . . . . . . . . . . . . . 124<br />
N9316520 . . . . . . . . . . . . . . . . . . . . . . . . . . 127<br />
N9316521 . . . . . . . . . . . . . . . . . . . . . . . . . . 127<br />
N9316534 . . . . . . . . . . . . . . . . . . . . . . . . . . 123<br />
N9316535 . . . . . . . . . . . . . . . . . . . . . . . . . . 123<br />
N9316536 . . . . . . . . . . . . . . . . . . . . . . . . . . 123<br />
N9316537 . . . . . . . . . . . . . . . . . . . . . . . . . . 123<br />
N9316538 . . . . . . . . . . . . . . . . . . . . . . . . . . 123<br />
N9316539 . . . . . . . . . . . . . . . . . . . . . . . . . . 123<br />
N9316540 . . . . . . . . . . . . . . . . . . . . . . . . . . 123<br />
N9316541 . . . . . . . . . . . . . . . . . . . . . . . . . . 123<br />
N9316542 . . . . . . . . . . . . . . . . . . . . . . . . . . 123<br />
N9316544 . . . . . . . . . . . . . . . . . . . . . . . . . . 129<br />
N9316545 . . . . . . . . . . . . . . . . . . . . . . . . . . 129<br />
N9316546 . . . . . . . . . . . . . . . . . . . . . . . . . . 129<br />
N9316547 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />
N9316548 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />
N9316549 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />
N9316550 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />
N9316551 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />
N9316552 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />
N9316553 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />
N9316554 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />
N9316555 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />
N9316556 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />
N9316557 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />
N9316558 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />
N9316559 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />
N9316560 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />
N9316561 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />
N9316562 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />
N9316563 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />
N9316564 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />
N9316565 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />
N9316566 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />
N9316567 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />
N9316568 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />
N9316569 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />
N9316570 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />
N9316571 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />
N9316572 . . . . . . . . . . . . . . . . . . . . . . . . . . 127<br />
N9316573 . . . . . . . . . . . . . . . . . . . . . . . . . . 125<br />
N9316574 . . . . . . . . . . . . . . . . . . . . . . . . . . 125<br />
N9316575 . . . . . . . . . . . . . . . . . . . . . . . . . . 125<br />
N9316576 . . . . . . . . . . . . . . . . . . . . . . . . . . 125<br />
N9316577 . . . . . . . . . . . . . . . . . . . . . . . . . . 125<br />
N9316578 . . . . . . . . . . . . . . . . . . . . . . . . . . 125<br />
N9316579 . . . . . . . . . . . . . . . . . . . . . . . . . . 125<br />
N9316601 . . . . . . . . . . . . . . . . . . . . . . . . . . 129<br />
N9316602 . . . . . . . . . . . . . . . . . . . . . . . . . . 129<br />
N9316603 . . . . . . . . . . . . . . . . . . . . . . . . . . 129<br />
N9316604 . . . . . . . . . . . . . . . . . . . . . . . . . . 129<br />
N9316605 . . . . . . . . . . . . . . . . . . . . . . . . . . 129<br />
N9316606 . . . . . . . . . . . . . . . . . . . . . . . . . . 129<br />
N9316607 . . . . . . . . . . . . . . . . . . . . . . 129, 144<br />
N9316608 . . . . . . . . . . . . . . . . . . . . . . 129, 144<br />
N9316609 . . . . . . . . . . . . . . . . . . . . . . . . . . 129<br />
N9316610 . . . . . . . . . . . . . . . . . . . . . . . . . . 124<br />
N9316611 . . . . . . . . . . . . . . . . . . . . . . . . . . 124<br />
N9316612 . . . . . . . . . . . . . . . . . . . . . . . . . . 124<br />
N9316613 . . . . . . . . . . . . . . . . . . . . . . . . . . 124<br />
N9316614 . . . . . . . . . . . . . . . . . . . . . . . . . . 124<br />
N9316615 . . . . . . . . . . . . . . . . . . . . . . . . . . 124<br />
N9316616 . . . . . . . . . . . . . . . . . . . . . . . . . . 124<br />
N9316617 . . . . . . . . . . . . . . . . . . . . . . . . . . 124<br />
N9316618 . . . . . . . . . . . . . . . . . . . . . . . . . . 124<br />
N9316619 . . . . . . . . . . . . . . . . . . . . . . . . . . 124<br />
N9316620 . . . . . . . . . . . . . . . . . . . . . . . . . . 124<br />
N9316621 . . . . . . . . . . . . . . . . . . . . . . . . . . 124<br />
N9316622 . . . . . . . . . . . . . . . . . . . . . . . . . . 124<br />
N9316623 . . . . . . . . . . . . . . . . . . . . . . . . . . 124<br />
N9316624 . . . . . . . . . . . . . . . . . . . . . . . . . . 124<br />
N9316625 . . . . . . . . . . . . . . . . . . . . . . . . . . 124<br />
N9316626 . . . . . . . . . . . . . . . . . . . . . . . . . . 124<br />
N9316627 . . . . . . . . . . . . . . . . . . . . . . . . . . 124<br />
Part No. Page Part No. Page Part No. Page<br />
See page 4 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
See page 2 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong>
Index<br />
Index Part Number N9316628 – WE029013<br />
Part Number<br />
Part No. Page Part No. Page Part No. Page<br />
N9316628 . . . . . . . . . . . . . . . . . . . . . . . . . . 124<br />
N9316629 . . . . . . . . . . . . . . . . . . . . . . . . . . 124<br />
N9316630 . . . . . . . . . . . . . . . . . . . . . . . . . . 124<br />
N9316631 . . . . . . . . . . . . . . . . . . . . . . . . . . 124<br />
N9316632 . . . . . . . . . . . . . . . . . . . . . . . . . . 124<br />
N9316633 . . . . . . . . . . . . . . . . . . . . . . . . . . 124<br />
N9316634 . . . . . . . . . . . . . . . . . . . . . . . . . . 124<br />
N9316635 . . . . . . . . . . . . . . . . . . . . . . . . . . 124<br />
N9316636 . . . . . . . . . . . . . . . . . . . . . . . . . . 124<br />
N9316637 . . . . . . . . . . . . . . . . . . . . . . . . . . 124<br />
N9316638 . . . . . . . . . . . . . . . . . . . . . . . . . . 124<br />
N9316639 . . . . . . . . . . . . . . . . . . . . . . . . . . 124<br />
N9316640 . . . . . . . . . . . . . . . . . . . . . . . . . . 124<br />
N9316641 . . . . . . . . . . . . . . . . . . . . . . . . . . 124<br />
N9316642 . . . . . . . . . . . . . . . . . . . . . . . . . . 124<br />
N9316643 . . . . . . . . . . . . . . . . . . . . . . . . . . 124<br />
N9316644 . . . . . . . . . . . . . . . . . . . . . . . . . . 124<br />
N9316645 . . . . . . . . . . . . . . . . . . . . . . . . . . 124<br />
N9316646 . . . . . . . . . . . . . . . . . . . . . . . . . . 124<br />
N9316647 . . . . . . . . . . . . . . . . . . . . . . . . . . 124<br />
N9316648 . . . . . . . . . . . . . . . . . . . . . . . . . . 124<br />
N9316649 . . . . . . . . . . . . . . . . . . . . . . . . . . 124<br />
N9316650 . . . . . . . . . . . . . . . . . . . . . . . . . . 127<br />
N9316651 . . . . . . . . . . . . . . . . . . . . . . . . . . 127<br />
N9316652 . . . . . . . . . . . . . . . . . . . . . . . . . . 127<br />
N9316653 . . . . . . . . . . . . . . . . . . . . . . . . . . 127<br />
N9316654 . . . . . . . . . . . . . . . . . . . . . . . . . . 127<br />
N9316655 . . . . . . . . . . . . . . . . . . . . . . . . . . 127<br />
N9316656 . . . . . . . . . . . . . . . . . . . . . . . . . . 127<br />
N9316657 . . . . . . . . . . . . . . . . . . . . . . . . . . 127<br />
N9316658 . . . . . . . . . . . . . . . . . . . . . . . . . . 127<br />
N9316659 . . . . . . . . . . . . . . . . . . . . . . . . . . 127<br />
N9316660 . . . . . . . . . . . . . . . . . . . . . . . . . . 127<br />
N9316661 . . . . . . . . . . . . . . . . . . . . . . . . . . 126<br />
N9316662 . . . . . . . . . . . . . . . . . . . . . . . . . . 126<br />
N9316663 . . . . . . . . . . . . . . . . . . . . . . . . . . 126<br />
N9316664 . . . . . . . . . . . . . . . . . . . . . . . . . . 126<br />
N9316665 . . . . . . . . . . . . . . . . . . . . . . . . . . 126<br />
N9316666 . . . . . . . . . . . . . . . . . . . . . . . . . . 126<br />
N9316667 . . . . . . . . . . . . . . . . . . . . . . . . . . 126<br />
N9316668 . . . . . . . . . . . . . . . . . . . . . . . . . . 126<br />
N9316669 . . . . . . . . . . . . . . . . . . . . . . . . . . 126<br />
N9316670 . . . . . . . . . . . . . . . . . . . . . . . . . . 126<br />
N9316671 . . . . . . . . . . . . . . . . . . . . . . . . . . 126<br />
N9316672 . . . . . . . . . . . . . . . . . . . . . . . . . . 126<br />
N9316673 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />
N9316674 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />
N9316675 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />
N9316676 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />
N9316677 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />
N9316678 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />
N9316679 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />
N9316680 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />
N9316681 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />
N9316682 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />
N9316684 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />
PELA1005 . . . . . . . . . . . . . . . . . . . . . . . . . . 380<br />
PELA1006 . . . . . . . . . . . . . . . . . . . . . . . . . . 380<br />
PELA1008 . . . . . . . . . . . . . . . . . . . . . . . . . . 380<br />
PELA1013 . . . . . . . . . . . . . . . . . . . . . . . . . . 380<br />
PELA1014 . . . . . . . . . . . . . . . . . . . . . . . . . . 380<br />
PELA1015 . . . . . . . . . . . . . . . . . . . . . . . . . . 380<br />
PELA1022 . . . . . . . . . . . . . . . . . . . . . . . . . . 381<br />
PELA9010 . . . . . . . . . . . . . . . . . . . . . . . . . . 396<br />
PELA9012 . . . . . . . . . . . . . . . . . . . . . . . . . . 396<br />
PELA9013 . . . . . . . . . . . . . . . . . . . . . . . . . . 396<br />
PELA9018 . . . . . . . . . . . . . . . . . . . . . . . . . . 396<br />
PELA9019 . . . . . . . . . . . . . . . . . . . . . . . . . . 396<br />
PELA9020 . . . . . . . . . . . . . . . . . . . . . . . . . . 396<br />
PELA9021 . . . . . . . . . . . . . . . . . . . . . . . . . . 396<br />
PELA9038 . . . . . . . . . . . . . . . . . . . . . . . . . . 381<br />
PELA9039 . . . . . . . . . . . . . . . . . . . . . . . . . . 381<br />
PELA9040 . . . . . . . . . . . . . . . . . . . . . . . . . . 384<br />
PELA9042 . . . . . . . . . . . . . . . . . . . . . . . . . . 381<br />
PELA9057 . . . . . . . . . . . . . . . . . . . . . . . . . . 396<br />
PELA9058 . . . . . . . . . . . . . . . . . . . . . . . . . . 396<br />
S2000203 . . . . . . . . . . . . . . . . . . . . . . . . . . 178<br />
S2000204 . . . . . . . . . . . . . . . . . . . . . . . . . . 178<br />
S2000205 . . . . . . . . . . . . . . . . . . . . . . . . . . 178<br />
S2000206 . . . . . . . . . . . . . . . . . . . . . . . . . . 178<br />
S2700055 . . . . . . . . . . . . . . . . . . . . . . . . . . 332<br />
S2701017 . . . . . . . . . . . . . . . . . . . . . . . . . . 138<br />
S2701116 . . . . . . . . . . . . . . . . . . . . . . . . . . 138<br />
S2701610 . . . . . . . . . . . . . . . . . . . . . . . . . . 137<br />
S5010013 . . . . . . . . . . . . . . . . . . . . . . 177, 331<br />
S5010015 . . . . . . . . . . . . . . . . . . . . . . 177, 331<br />
S5010016 . . . . . . . . . . . . . . . . . . . . . . 177, 331<br />
S5010017 . . . . . . . . . . . . . . . . . . . . . . 177, 331<br />
S5010018 . . . . . . . . . . . . . . . . . . . . . . 177, 331<br />
S5010019 . . . . . . . . . . . . . . . . . . . . . . 177, 331<br />
S5010020 . . . . . . . . . . . . . . . . . . . . . . 177, 331<br />
S5010021 . . . . . . . . . . . . . . . . . . . . . . 177, 331<br />
S5010022 . . . . . . . . . . . . . . . . . . . . . . 177, 331<br />
S5010023 . . . . . . . . . . . . . . . . . . . . . . 177, 331<br />
S5010024 . . . . . . . . . . . . . . . . . . . . . . 177, 331<br />
S5010025 . . . . . . . . . . . . . . . . . . 137, 177, 331<br />
S5010030 . . . . . . . . . . . . . . . . . . 137, 177, 331<br />
S5010031 . . . . . . . . . . . . . . . . . . . . . . 177, 331<br />
S5010032 . . . . . . . . . . . . . . . . . . . . . . 177, 331<br />
S5010033 . . . . . . . . . . . . . . . . . . . . . . 177, 331<br />
S5010034 . . . . . . . . . . . . . . . . . . . . . . 177, 331<br />
S5010035 . . . . . . . . . . . . . . . . . . . . . . 177, 331<br />
S5010036 . . . . . . . . . . . . . . . . . . . . . . 177, 331<br />
S5010037 . . . . . . . . . . . . . . . . . . . . . . 177, 331<br />
S5010038 . . . . . . . . . . . . . . . . . . . . . . 177, 331<br />
S5010039 . . . . . . . . . . . . . . . . . . . . . . 177, 331<br />
S5010040 . . . . . . . . . . . . . . . . . . . . . . 177, 331<br />
S5010041 . . . . . . . . . . . . . . . . . . . . . . 177, 331<br />
S9000070 . . . . . . . . . . . . . . . . . . . . . . 174, 329<br />
S9000075 . . . . . . . . . . . . . . . . . . . . . . 174, 329<br />
S9000090 . . . . . . . . . . . . . . . . . . . . . . 174, 329<br />
S9000095 . . . . . . . . . . . . . . . . . . . . . . 174, 329<br />
S9000160 . . . . . . . . . . . . . . . . . . . . . . 176, 330<br />
S9000165 . . . . . . . . . . . . . . . . . . . . . . 176, 330<br />
W1006057 . . . . . . . . . . . . . . . . . . . . . . . . . 192<br />
W1007468 . . . . . . . . . . . . . . . . . . . . . . . . . 205<br />
W1007493 . . . . . . . . . . . . . . . . . . . . . . . . . 208<br />
W1008384 . . . . . . . . . . . . . . . . . . . . . . . . . 205<br />
W1008680 . . . . . . . . . . . . . . . . . . . . . . . . . 192<br />
W1010598 . . . . . . . . . . . . . . . . . . . . . . . . . 190<br />
W1010620 . . . . . . . . . . . . . . . . . . . . . . . . . 190<br />
W1012406 . . . . . . . . . . . . . . . . . . . . . 195, 205<br />
W1012408 . . . . . . . . . . . . . . . . . . . . . . . . . 205<br />
W1012409 . . . . . . . . . . . . . . . . . . . . . . . . . 205<br />
W1012410 . . . . . . . . . . . . . . . . . . . . . . . . . 205<br />
W1012771 . . . . . . . . . . . . . . . . . . . . . . . . . 192<br />
W1013195 . . . . . . . . . . . . . . . . . . . . . . . . . 190<br />
W1013266 . . . . . . . . . . . . . . . . . . . . . 195, 205<br />
W1013361 . . . . . . . . . . . . . . . . . . . . . . . . . 190<br />
W1013545 . . . . . . . . . . . . . . . . . . . . . 195, 205<br />
W1013691 . . . . . . . . . . . . . . . . . . . . . . . . . 206<br />
W1015115 . . . . . . . . . . . . . . . . . . . . . . . . . 206<br />
W1017871 . . . . . . . . . . . . . . . . . . . . . . . . . 190<br />
W1020331 . . . . . . . . . . . . . . . . . . . . . 202, 205<br />
W1020668 . . . . . . . . . . . . . . . . . . . . . . . . . 205<br />
W1020672 . . . . . . . . . . . . . . . . . . . . . . . . . 205<br />
W1020996 . . . . . . . . . . . . . . . . . . 201-202, 205<br />
WE012411 . . . . . . . . . . . . . . . . . . . . . . . . . 205<br />
WE012687 . . . . . . . . . . . . . . . . . . . . . . . . . 193<br />
WE012989 . . . . . . . . . . . . . . . . . . . . . . . . . 189<br />
WE013060 . . . . . . . . . . . . . . . . . . . . . 201, 204<br />
WE013087 . . . . . . . . . . . . . . . . . . . . . . . . . 189<br />
WE013119 . . . . . . . . . . . . . . . . . . . . . 201, 204<br />
WE013829 . . . . . . . . . . . . . . . . . . . . . . . . . 204<br />
WE014034 . . . . . . . . . . . . . . . . . . . . . . . . . 202<br />
WE014081 . . . . . . . . . . . . . . . . . . . . . 201, 204<br />
WE014777 . . . . . . . . . . . . . . . . . . . . . . . . . 190<br />
WE015554 . . . . . . . . . . . . . . . . . . . . . . . . . 205<br />
WE015772 . . . . . . . . . . . . . . . . . . . . . . . . . 191<br />
WE016558 . . . . . . . . . . . . . . . . . . . . . . . . . 190<br />
WE017142 . . . . . . . . . . . . . . . . . . . . . . . . . 189<br />
WE017603 . . . . . . . . . . . . . . . . . . . . . . . . . 192<br />
WE018034 . . . . . . . . . . . . . . . . . . . . . 190, 193<br />
WE018076 . . . . . . . . . . . . . . . . . . . . . . . . . 191<br />
WE018079 . . . . . . . . . . . . . . . . . . . . . . . . . 191<br />
WE018355 . . . . . . . . . . . . . . . . . . . . . . . . . 191<br />
WE021074 . . . . . . . . . . . . . . . . . . . . . . . . . 193<br />
WE021137 . . . . . . . . . . . . . . . . . . . . . 189, 193<br />
WE021140 . . . . . . . . . . . . . . . . . . . . . 189, 193<br />
WE021816 . . . . . . . . . . . . . . . . . . . . . 193, 205<br />
WE022567 . . . . . . . . . . . . . . . . . . . . . . . . . 193<br />
WE023257 . . . . . . . . . . . . . . . . . . . . . . . . . 192<br />
WE023935 . . . . . . . . . . . . . . . . . . . . . . . . . 192<br />
WE023948 . . . . . . . . . . . . . . . . . . . . . 193, 195<br />
WE023951 . . . . . . . . . . . . . . . . . 193, 195, 201<br />
WE024354 . . . . . . . . . . . . . . . . . . . . . . . . . 192<br />
WE024371 . . . . . . . . . . . . . . . . . . . . . 196, 201<br />
WE024372 . . . . . . . . . . . . . . . . . 193, 196, 201<br />
WE024375 . . . . . . . . . . . . . . . . . . . . . 193, 196<br />
WE024782 . . . . . . . . . . . . . . . . . . . . . . . . . 200<br />
WE025221. . . . . . . . . . . . . . . . . . . . . . 201-202<br />
WE025239. . . . . . . . . . . . . . . . . . . . . . 201-202<br />
WE027005 . . . . . . . . . . . . . . . . . . . . . . . . . 195<br />
WE027030 . . . . . . . . . . . . . . . . . . . . . . . . . 195<br />
WE027567 . . . . . . . . . . . . . . . . . . . . . . . . . 192<br />
WE027802 . . . . . . . . . . . . . . . . . . . . . 189, 193<br />
WE027803 . . . . . . . . . . . . . . . . . . . . . 189, 193<br />
WE028426 . . . . . . . . . . . . . . . . . . . . . . . . . 191<br />
WE028427 . . . . . . . . . . . . . . . . . . . . . . . . . 191<br />
WE028428 . . . . . . . . . . . . . . . . . . . . . . . . . 191<br />
WE028439 . . . . . . . . . . . . . . . . . . . . . . . . . 192<br />
WE029011 . . . . . . . . . . . . . . . . . . . . . . . . . 190<br />
WE029013 . . . . . . . . . . . . . . . . . . . . . . . . . 192<br />
428
Atomic Absorption Index<br />
Alphabetical<br />
Amalgamation System Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . .26<br />
AutoPrep 50 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10<br />
Autosampler Supplies and Accessories . . . . . . . . . . . . . . . . . . . . .8-12<br />
Autosampler Flame/FIAS Probes . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9<br />
Sampling Probe Assemblies and Components . . . . . . . . . . . . . . . .9<br />
Sampling Probe Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9<br />
Autosampler Flame/FIAS Trays and Vessels . . . . . . . . . . . . . . . . . . . . .8<br />
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8<br />
Rinsing Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8<br />
Sample Trays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8<br />
Sample Vessels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8<br />
Tubes and Beakers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8<br />
Dilution System Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10<br />
AutoPrep 50 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10<br />
Graphite Furnace Autosampler Supplies . . . . . . . . . . . . . . . . . . . .11-12<br />
Autosampler Sample Cups . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11<br />
Autosampler Trays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11<br />
Check Valves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11<br />
Ferrule Kits and Tubing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12<br />
Reagent Containers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12<br />
Sampling Capillaries . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12<br />
Burner Heads . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13-15<br />
AAnalyst 100/200/300/400/700/800 . . . . . . . . . . . . . . . . . . . . . . . .13<br />
Models 1100(B), 2100, and 4100 . . . . . . . . . . . . . . . . . . . . . . . . . . .15<br />
Models 2280, 2380, 3030(B), 3100, 3110, 3300,<br />
4000, 5000, and 5100 PC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14<br />
Burner System Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13-20<br />
AAnalyst 100/200/300/400/700/800 . . . . . . . . . . . . . . . . . . . . . . . .13<br />
Burner Heads . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13<br />
Burner System Components . . . . . . . . . . . . . . . . . . . . . . . . . . . .13<br />
Drain Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13<br />
Models 1100(B), 2100, and 4100 . . . . . . . . . . . . . . . . . . . . . . . . . . .15<br />
Burner Heads . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15<br />
Models 2280, 2380, 3030(B), 3100, 3110, 3300,<br />
4000, 5000, and 5100 PC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14<br />
Cable and Pin Assemblies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14<br />
Nebulizer Assemblies and Components Quick Reference . . . . . . . . . . .17<br />
Plastic Body Nebulizers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17<br />
Stainless Steel Body Nebulizers . . . . . . . . . . . . . . . . . . . . . . . . . .17<br />
Nebulizers and Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18-20<br />
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18<br />
GemTip Nebulizers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18<br />
High-Sensitivity Nebulizer with Pt/Ir Capillary . . . . . . . . . . . . . . . .19<br />
High-Sensitivity Nebulizers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19<br />
Stainless Steel Body Nebulizers and Parts . . . . . . . . . . . . . . . . . .20<br />
Contact Cylinders . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31, 34<br />
HGA Contact Cylinders . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31<br />
THGA Contact Cylinders . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34<br />
Flow Injection Sampling Supplies . . . . . . . . . . . . . . . . . . . . . . . .21-28<br />
FIAS and FIMS Parts and Supplies . . . . . . . . . . . . . . . . . . . . . . . .22-23<br />
FIAS Cells and Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22<br />
FIMS Cells and Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22<br />
Gas/Liquid Separator Consumables . . . . . . . . . . . . . . . . . . . . . . .22<br />
Pump Magazines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23<br />
Spare Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23<br />
Switching Valves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23<br />
FIAS and FIMS Tubing Adapters and Connectors . . . . . . . . . . . . . . . . .24<br />
Adapters with Internal Threads . . . . . . . . . . . . . . . . . . . . . . . . . .24<br />
Adapters with External Threads . . . . . . . . . . . . . . . . . . . . . . . . . .24<br />
Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24<br />
FIAS and FIMS Tubing and Supplies . . . . . . . . . . . . . . . . . . . . . . . . . .25<br />
Peristaltic Pump Tubing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25<br />
PTFE Tubing, Screw Connectors, and O-Rings . . . . . . . . . . . . . . .25<br />
Sample Loops . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25<br />
Flow Injection Amalgamation System . . . . . . . . . . . . . . . . . . . . . . . . .26<br />
Amalgamation System and Supplies . . . . . . . . . . . . . . . . . . . . . .26<br />
Flow Injection Analysis and Mercury Systems . . . . . . . . . . . . . . . . . . .21<br />
Flow Injection Furnace Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27<br />
FIAS-Furnace Coupling Kit and Supplies . . . . . . . . . . . . . . . . . . . .27<br />
Flow Injection Preconcentration Kit and Supplies . . . . . . . . . . . . . . . . .28<br />
Flow Injection Sampling Valves and Supplies . . . . . . . . . . . . . . . .28<br />
Peristaltic Pump Tubing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28<br />
Preconcentration Columns . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28<br />
PTFE Tubing Assemblies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28<br />
Tubing Adapters and Connectors . . . . . . . . . . . . . . . . . . . . . . . . .28<br />
Graphite Furnace Tubes and Supplies . . . . . . . . . . . . . . . . . . . . .31-35<br />
HGA Graphite Contact Cylinders, Tubes, and Supplies . . . . . . . . . .31-32<br />
Circulatory Cooling System . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33<br />
Contact Cylinders . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31<br />
HGA Graphite Cooling Systems and Quartz Windows . . . . . . . . . . .33<br />
L'vov Platforms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31<br />
Matrix Modifiers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32<br />
Pyrocoated Graphite Tubes (Grooved) . . . . . . . . . . . . . . . . . . . . . .32<br />
Pyrocoated Graphite Tubes with Integrated Platform . . . . . . . . . . .32<br />
Quartz Window Components . . . . . . . . . . . . . . . . . . . . . . . . . . . .33<br />
Quartz Windows . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35<br />
Uncoated Graphite Tubes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32<br />
THGA Graphite Contact Cylinders, Tubes, and Supplies . . . . . . . . .34-35<br />
Contact Cylinders . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34<br />
Graphite Tubes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34<br />
Matrix Modifiers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35<br />
Spare Parts and Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35<br />
Graphite Tubes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32, 34<br />
HGA Graphite Tubes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32<br />
THGA Graphite Tubes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34<br />
High Pressure Asher System Supplies . . . . . . . . . . . . . . . . . . . . .51-52<br />
Laboratory Products . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .36-38<br />
Filters, Regulators, and Supplies . . . . . . . . . . . . . . . . . . . . . . . . . .36-38<br />
Filters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .36<br />
Flash Arrestor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .37<br />
Hose Assemblies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .37<br />
Instrument Filters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .37<br />
MiniDispenser . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .37<br />
Regulators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .38<br />
Venting System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .38<br />
Lamps for Atomic Absorption . . . . . . . . . . . . . . . . . . . . . . . . . . . .39-48<br />
Lumina Hollow Cathode Lamp Coded Adapters . . . . . . . . . . . . . . . . . .43<br />
Coded Lumina Adapters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .43<br />
Lumina Hollow Cathode Lamps . . . . . . . . . . . . . . . . . . . . . . . . . . .39-43<br />
Features and Benefits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .39<br />
Lumina Lamps and Lamps with Adapters . . . . . . . . . . . . . . . .40-41<br />
Lumina Multi-Element Hollow Cathode Lamps . . . . . . . . . . . . . . .42<br />
Non-Coded Hollow Cathode Lamp Adapters . . . . . . . . . . . . . . . . . . . .44<br />
Lamp Plug Adapters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .44<br />
Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .45<br />
Background Corrector Sources . . . . . . . . . . . . . . . . . . . . . . . . . .45<br />
Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .45<br />
System 2 EDL Lamp Supplies and Accessories . . . . . . . . . . . . . . . . . .48<br />
EDL Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .48<br />
EDL Driver Assemblies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .48<br />
System 2 EDL Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . .48<br />
Alphabetical Atomic Absorption Index<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
429
Atomic Absorption Index<br />
Alphabetical<br />
System 2 EDL Lamps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .46-47<br />
Features and Benefits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .46<br />
System 2 EDL Lamps and Adapters . . . . . . . . . . . . . . . . . . . . . . .47<br />
Matrix Modifiers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .67<br />
Mercury/Hydride System and Supplies . . . . . . . . . . . . . . . . . . . . . . .49<br />
MHS, Quartz Cells, and Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . .49<br />
Quartz Cells . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .49<br />
MiniDispenser . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .37<br />
Multiwave Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .53-55<br />
PerkinElmer Pure Atomic Absorption Standards . . . . . . . . . . . . . . .66-67<br />
Alternate Trace Metal Drinking<br />
CLP Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .66<br />
Contract Required Detection Limits (CRDL) Standard . . . . . . . . . . .67<br />
Groundwater and Wastewater<br />
Pollution Control Check Standards . . . . . . . . . . . . . . . . . . . . . . . .67<br />
Pollution and Wastewater Standards . . . . . . . . . . . . . . . . . . . . . .66<br />
Reagents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .67<br />
Tubing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24-25<br />
Adapters and Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24<br />
Peristaltic Pump Tubing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25<br />
PTFE Tubing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25<br />
Atomic Absorption Index Alphabetical<br />
Multiwave 3000 Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .57-64<br />
Rotor 1 DRY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .62<br />
Rotor 8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .57-59<br />
Rotor 8 EVAP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .62<br />
Rotor 8 SOLV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .63-64<br />
Rotor 16 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .60-61<br />
Nebulizers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17-20<br />
Gemtip . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18<br />
High-Sensitivity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19<br />
Quick Reference . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17<br />
Stainless Steel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20<br />
Sample Cups and Vessels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8, 11<br />
Autosampler Vessels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8<br />
Graphite Furnace Autosampler Sample Cups . . . . . . . . . . . . . . . . . . .11<br />
Sample Preparation Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . .50-64<br />
High Pressure Asher System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50<br />
High Pressure Asher System Supplies . . . . . . . . . . . . . . . . . . . . . .51-52<br />
Heat Trays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .51<br />
Reaction Vessel Racks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .51<br />
Reaction Vessel Sets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .51<br />
Reaction Vessels and Lids . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .51<br />
Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .52<br />
Multiwave . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .53-55<br />
Multiwave Accessories and Supplies . . . . . . . . . . . . . . . . . . . .53-55<br />
Reaction Vessel Assemblies . . . . . . . . . . . . . . . . . . . . . . . . . . . . .54<br />
Reaction Vessel Racks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .55<br />
Rotors and Rotor Assemblies . . . . . . . . . . . . . . . . . . . . . . . . . . . .55<br />
Multiwave 3000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .56-64<br />
Multiwave 3000 Accessories and Supplies . . . . . . . . . . . . . . .56-64<br />
Multiwave 3000 Digestion Rotors . . . . . . . . . . . . . . . . . . . . . . . . .57-61<br />
Rotor 8 Consumables and Vessels . . . . . . . . . . . . . . . . . . . . .57-58<br />
Rotor 8 Spare Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .59<br />
Rotor 16 Consumables and Vessels . . . . . . . . . . . . . . . . . . . . . . .60<br />
Rotor 16 Spare Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .61<br />
Multiwave 3000 Drying and Evaporation Rotors . . . . . . . . . . . . . . . . .62<br />
Rotor 1 DRY Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .62<br />
Rotor 8 EVAP Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .62<br />
Multiwave 3000 Solvent Extraction Rotors . . . . . . . . . . . . . . . . . . . . .63<br />
Rotor 8 SOLV Consumables and Vessels . . . . . . . . . . . . . . . . . . .63<br />
Multiwave 3000 Solvent Extraction Rotors and System Spare Parts . . .64<br />
Rotor 8 SOLV Spare Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .64<br />
System Spare Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .64<br />
Sampling Probes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9<br />
Assemblies and Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9<br />
Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .65-69<br />
PerkinElmer Pure Atomic Absorption Standards . . . . . . . . . . . . . . .66-69<br />
Single-Element Calibration Standards . . . . . . . . . . . . . . . . . . .68-69<br />
WinLab32 Software for AA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .70-71<br />
Software for Atomic Absorption Analysis . . . . . . . . . . . . . . . . . . . .70-71<br />
Windows . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33, 35<br />
HGA Quartz Windows . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33<br />
THGA Quartz Windows . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35<br />
430
Elemental Analysis Index<br />
Alphabetical<br />
2400 Series II Analysis Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .76<br />
Analysis Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .76<br />
CHN Analysis Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .76<br />
CHNS Analysis Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .76<br />
Oxygen Analysis Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .76<br />
Calibration Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .80<br />
Gas Pressure Regulators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .77<br />
Laboratory Products . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .77<br />
For the 2400/2410 Series II Analyzers . . . . . . . . . . . . . . . . . . . . . . . .77<br />
Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .77<br />
Gas Lines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .77<br />
Gas Pressure Regulators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .77<br />
Printer Kit and Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .77<br />
Packing Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .78-79<br />
Reagents, Tubes, and Receptacles . . . . . . . . . . . . . . . . . . . . . . . .78-79<br />
2400 Tubes and Reagent Kits . . . . . . . . . . . . . . . . . . . . . . . . . . .78<br />
Packing Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .78<br />
Receptacles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .79<br />
Tubes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .79<br />
Reagents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .78<br />
Sample Handling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .80<br />
Calibration Standards, Capsules, and Supplies . . . . . . . . . . . . . . . . . .80<br />
Calibration Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .80<br />
Sample Capsules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .80<br />
Sample Handling Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . .80<br />
Sealers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .80<br />
Spare Parts and Tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .81-83<br />
Autoinjector and Fitting Spares . . . . . . . . . . . . . . . . . . . . . . . . . . . . .81<br />
Autoinjector Spares . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .81<br />
Fittings for Combustion<br />
and Reduction Tubes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .81<br />
Fittings and Tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .82<br />
Fittings for Scrubber . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .82<br />
Spare Parts for 2400/2410 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .82<br />
Tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .82<br />
Valve Spares . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .83<br />
Ultramicrobalance Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .375<br />
Alphabetical Elemental Analysis Index<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
431
Gas Chromatography Index<br />
Alphabetical<br />
Gas Chromatography Index Alphabetical<br />
Autosampler Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .88-90<br />
Syringes and Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .88<br />
Autosampler Replacement Parts . . . . . . . . . . . . . . . . . . . . . . . . .88<br />
Miscellaneous Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . .88<br />
Syringes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .88<br />
Vial Crimping Tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .90<br />
Crimping Tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .90<br />
Vials, Caps, and Septa . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .89<br />
Crimp Caps and Septa . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .89<br />
Crimp Top Sample Vials . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .89<br />
Screw Top Sample Vials and Caps . . . . . . . . . . . . . . . . . . . . . . . .89<br />
Vial Holder Racks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .89<br />
Waste Vials . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .89<br />
Capillary Column Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . .92-95<br />
Adapter Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .92<br />
Connectors and Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .93<br />
Column Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .93<br />
Tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .93<br />
Uncoated Deactivated Fused-Silica Capillary Tubing . . . . . . . . . . .93<br />
Universal Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .93<br />
Ferrules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .94<br />
Graphite and Vespel Ferrules . . . . . . . . . . . . . . . . . . . . . . . . . . . .94<br />
SilTite Ferrules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .94<br />
Fittings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .95<br />
Swagelok Fittings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .95<br />
Capillary Column Applications . . . . . . . . . . . . . . . . . . . . . . . . . .99-119<br />
Environmental . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .99-109<br />
Food and Flavors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .110-112<br />
Forensics/Clinical Toxicology . . . . . . . . . . . . . . . . . . . . . . . . . . .113-115<br />
Industrial Chemicals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .116-118<br />
Petroleum . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .119<br />
Capillary Columns . . . . . . . . . . . . . . . . . . . . . . . . . .91, 97-98, 120-130<br />
Capillary Columns . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .91<br />
U.S. EPA Methods . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .97-98<br />
U.S. EPA Drinking Water Test Methods . . . . . . . . . . . . . . . . . . . . .97<br />
U.S. EPA Organic Chemical Analysis Waste Water Methods . . . . . .97<br />
U.S. EPA Solid Waste Test Methods . . . . . . . . . . . . . . . . . . . . . . .98<br />
Phase Cross-Reference . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .120<br />
PerkinElmer Elite Series Capillary Columns . . . . . . . . . . . . . . . .121-128<br />
Elite-1ht (High-Temp) Dimethylpolysiloxane . . . . . . . . . . . . . . . . .121<br />
Elite-1 Dimethylpolysiloxane . . . . . . . . . . . . . . . . . . . . . . . . . . .121<br />
Elite-5 Amine . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .122<br />
Elite-5ht (High-Temp) (5% – Diphenyl) – Dimethylpolysiloxane . .122<br />
Elite-5ms (5% – Diphenyl) – Dimethylpolysiloxane . . . . . . . . . . .122<br />
Elite-5 (5% – Diphenyl) – Dimethylpolysiloxane . . . . . . . . . . . . .122<br />
Elite-17 (50% – Phenyl) – Methylpolysiloxane . . . . . . . . . . . . . .123<br />
Elite-17ht (High-Temp) (50% – Phenyl) – Methylpolysiloxane . . .123<br />
Elite-17ms (Low Bleed) (50% – Phenyl) – Methylpolysiloxane . . .123<br />
Elite-35 (35% – Diphenyl) – Dimethylpolysiloxane . . . . . . . . . . .123<br />
Elite-35ms (35% – Phenyl) – Methylpolysiloxane . . . . . . . . . . . .123<br />
Elite-200 Trifluoropropylmethyl Polysiloxane . . . . . . . . . . . . . . . .124<br />
Elite-225 (50% – Cyanopropylmethyl) –<br />
Phenylmethylpolysiloxane . . . . . . . . . . . . . . . . . . . . . . . . . . . . .124<br />
Elite-502.2 Specialty Phase for<br />
Analysis of Volatiles (U.S. EPA 502.2) . . . . . . . . . . . . . . . . . . . . .124<br />
Elite-608 Specialty Phase for<br />
Semivolatile Pesticides (U.S. EPA 608) . . . . . . . . . . . . . . . . . . . .124<br />
Elite-624 Specialty Phase for<br />
Analysis of Volatiles (U.S. EPA 624) . . . . . . . . . . . . . . . . . . . . . .125<br />
Elite-1301 (6% – Cyanopropylphenyl) – Methylpolysiloxane . . . .125<br />
Elite-1701 (14% – Cyanopropylphenyl) – Methylpolysiloxane . . .125<br />
Elite-BAC Blood Alcohol Analysis Columns for GC<br />
and High-Speed Headspace Gas Chromatography . . . . . . . . . . .125<br />
Elite-Betacydex Betacyclodextrin for Chiral Separations . . . . . . . .125<br />
Elite-CLPesticides . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .126<br />
Elite-CLPesticides 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .126<br />
Elite-FFAP Nitroterephthalic Acid Modified Polyethylene<br />
Glycol (Bonded) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .127<br />
Elite-HT SimDist for High-Temperature Simulated Distillation . . . .127<br />
Elite-MTBE Low Polarity Stationary Phase . . . . . . . . . . . . . . . . .127<br />
Elite-PONA Dimethylpolysiloxane Processed<br />
for Detailed Analysis of Petroleum Naphtha . . . . . . . . . . . . . . . .127<br />
Elite-RX for Analysis of Drugs of Abuse . . . . . . . . . . . . . . . . . . .127<br />
Elite-SimDist Dimethylpolysiloxane Processed<br />
for Simulated Distillation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .127<br />
Elite-TPH Specialty Phase for Analysis of<br />
Total Petroleum Hydrocarbons . . . . . . . . . . . . . . . . . . . . . . . . . .127<br />
Elite-VMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .127<br />
Elite-Volatiles Specialty Phase for Analysis of Volatile<br />
Organic Compounds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .127<br />
Elite-XLB Specialty Phase for GC/MS<br />
with Exceptionally Low Bleed . . . . . . . . . . . . . . . . . . . . . . . . . . .127<br />
Elite-MWAX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .128<br />
Elite-WAX ETR (Extended Temperature Range)<br />
Polyethylene Glycol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .128<br />
Elite-WAX Polyethylene Glycol . . . . . . . . . . . . . . . . . . . . . . . . . .128<br />
PerkinElmer Elite Series Guard and PLOT Columns . . . . . . . . . . . . . .129<br />
Elite-Alumina/KCI* PLOT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .129<br />
Elite-Alumina PLOT Phase for<br />
Analysis of Light Hydrocarbons . . . . . . . . . . . . . . . . . . . . . . . . .129<br />
Elite-Cyclosil B PLOT for Chiral Separations . . . . . . . . . . . . . . . .129<br />
Elite-Molesieve PLOT Phase for<br />
Analysis of Permanent Gases . . . . . . . . . . . . . . . . . . . . . . . . . .129<br />
Elite-Q PLOT Phase for Analysis of<br />
Light Gases and Hydrocarbons . . . . . . . . . . . . . . . . . . . . . . . . .129<br />
Elite Guard Columns . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .129<br />
PerkinElmer Packed Columns . . . . . . . . . . . . . . . . . . . . . . . . . . . . .130<br />
Packed Columns . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .130<br />
Detectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .131-141<br />
Electron Capture Detectors (ECD) . . . . . . . . . . . . . . . . . . . . . . . . . . .131<br />
Add-On Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .131<br />
Column Adapters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .131<br />
ECD Wipe Test Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .131<br />
Flame Ionization Detector (FID) Auto-Ignite . . . . . . . . . . . . . . . . . . . .132<br />
Add-On Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .132<br />
Auto-Ignite FID Replacement Parts . . . . . . . . . . . . . . . . . . . . . . .132<br />
Detector Series Operation Kit . . . . . . . . . . . . . . . . . . . . . . . . . . .132<br />
FID Miscellaneous Accessories . . . . . . . . . . . . . . . . . . . . . . . . .132<br />
Flame Ionization Detector (FID) External Igniter . . . . . . . . . . . . . . . . .133<br />
Add-On Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .133<br />
Replacement Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .133<br />
Flame Ionization Detector (FID) Replacement Parts . . . . . . . . . . . . . .134<br />
Catalytic Reactor Accessory . . . . . . . . . . . . . . . . . . . . . . . . . . . .134<br />
Catalytic Reactor Replacement Parts . . . . . . . . . . . . . . . . . . . . .134<br />
Miscellaneous Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . .134<br />
Flame Photometric Detector (FPD) . . . . . . . . . . . . . . . . . . . . . . . . . .135<br />
Add-On Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .135<br />
Mass Spectrometer Detector . . . . . . . . . . . . . . . . . . . . . . . . . .136-138<br />
Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .137<br />
Inner Source Replacement Parts . . . . . . . . . . . . . . . . . . . . . . . .137<br />
Ionizer Replacement Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . .137<br />
Manuals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .137<br />
Miscellaneous Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . .137<br />
Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .138<br />
Transfer Line . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .138<br />
Upgrade Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .138<br />
Nitrogen Phosphorus Detector (NPD) . . . . . . . . . . . . . . . . . . . . . . . .139<br />
Add-On Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .139<br />
Column Adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .139<br />
Replacement Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .139<br />
432
Gas Chromatography Index<br />
Alphabetical<br />
Photoionization Detector (PID) . . . . . . . . . . . . . . . . . . . . . . . . . . . . .140<br />
Add-On Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .140<br />
Detector Series Operation Kits . . . . . . . . . . . . . . . . . . . . . . . . . .140<br />
Miscellaneous Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . .140<br />
Replacement Lamps and Parts . . . . . . . . . . . . . . . . . . . . . . . . .140<br />
Thermal Conductivity Detector (TCD) . . . . . . . . . . . . . . . . . . . . . . . .141<br />
Add-On Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .141<br />
Column Adapters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .141<br />
TCD/FID Series Operation Kit . . . . . . . . . . . . . . . . . . . . . . . . . . .141<br />
Ferrules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .94<br />
Graphite . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .94<br />
Graphite/Vespel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .94<br />
SilTite . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .94<br />
Filters and Traps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .163<br />
Fittings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .95<br />
Capillary Columns . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .95<br />
Swagelok Fittings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .95<br />
Flow Meters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .167<br />
Digital Flow Meters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .167<br />
Electronic Flow Meter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .167<br />
Soap Bubble Flow Meter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .167<br />
Generators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .165<br />
Hydrogen Generators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .165<br />
Headspace Accessories and Supplies . . . . . . . . . . . . . . . . . . .142-149<br />
Add-On Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .143<br />
Headspce Add-On Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .143<br />
Headspace Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .144-147<br />
Extended Heated Transfer Line . . . . . . . . . . . . . . . . . . . . . . . . . .144<br />
Heated Transfer Line . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .144<br />
Remote Control Software (RCS) . . . . . . . . . . . . . . . . . . . . . . . . .145<br />
Sample Trays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .145<br />
Tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .145<br />
TurboMatrix and HS 40XL<br />
Adapter Kits for Non-PerkinElmer<br />
Gas Chromatographs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .146<br />
TurboMatrix Headspace/HS 40/<br />
HS 40XL Replacement Parts<br />
and Needle Identification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .147<br />
TurboMatrix Upgrade Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . .147<br />
Headspace Vials, Caps, and Septa . . . . . . . . . . . . . . . . . . . . . .148-149<br />
Headspace Caps and Septa . . . . . . . . . . . . . . . . . . . . . . . . . . .148<br />
Headspace Septa Recommended Temperature Chart . . . . . . . . .148<br />
Headspace Vials . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .148<br />
Vial Crimping Tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .149<br />
Injector Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .157-162<br />
Injector Liners . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .157-158<br />
Glass Inlet Liners . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .157<br />
Injector Septa . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .159<br />
Merlin MicroSeal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .159<br />
Septa for Use with All Injectors . . . . . . . . . . . . . . . . . . . . . . . . .159<br />
Subambient Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .160<br />
AutoSystem<br />
Subambient Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .160<br />
Subambient Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .160<br />
Syringes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .161-162<br />
Autosampler Syringes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .161<br />
Needle Syringes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .161<br />
Syringes – Gas Tight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .162<br />
Ultramicro Volume Syringes . . . . . . . . . . . . . . . . . . . . . . . . . . . .162<br />
Injectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .150-156<br />
Capillary Injectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .150-151<br />
Injector Replacement Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . .150<br />
Miscellaneous Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . .150<br />
Split/Splitless Injector Add-On Kits . . . . . . . . . . . . . . . . . . . . . . .151<br />
POC Injector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .154<br />
POC Replacement Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .154<br />
Programmed-Temperature<br />
On-Column Injector System . . . . . . . . . . . . . . . . . . . . . . . . . . . .154<br />
PSS Injector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .155<br />
Programmed-Temperature<br />
Split/Splitless Injector System . . . . . . . . . . . . . . . . . . . . . . . . . .155<br />
PSS Replacement Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .155<br />
Packed Column Injectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . .152-153<br />
Add-On Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .152<br />
Injector Replacement Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . .152<br />
Miscellaneous Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . .153<br />
Wide-Bore Adapter Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .153<br />
PreVent . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .156<br />
PreVent . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .156<br />
Inlet Liners . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .157<br />
Glass Inlet Liners . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .157<br />
Capillary Split/Splitless Liners . . . . . . . . . . . . . . . . . . . . . . . . . .157<br />
PSS Liners . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .158<br />
Packed Column Liners . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .158<br />
Laboratory Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .163-172<br />
Gas Sampling Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .163-165<br />
Filters and Traps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .163<br />
Gas Purification Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .164<br />
High Purity Brass Regulators . . . . . . . . . . . . . . . . . . . . . . . . . . .165<br />
PG-H2 Pure Gas Hydrogen Generators . . . . . . . . . . . . . . . . . . . .165<br />
Instrument Pneumatics Accessories . . . . . . . . . . . . . . . . . . . . . . . . .166<br />
Manual Pneumatics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .166<br />
PPC Frits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .166<br />
Maintenance Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .167<br />
Flow Meters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .167<br />
Tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .167<br />
Tubing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .167<br />
Valve Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .170-171<br />
Adapters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .170<br />
Air Actuators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .170<br />
Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .171<br />
Valve Fittings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .172<br />
Gas Sampling Valve Fittings . . . . . . . . . . . . . . . . . . . . . . . . . . . .172<br />
Valves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .168<br />
Valves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .168<br />
Valves/Loops . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .169<br />
Sample Loops . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .169<br />
Sample Loops . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .169<br />
Septa . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .159<br />
Injector Septa . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .159<br />
Low Bleed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .159<br />
Merlin MicroSeal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .159<br />
PTFE-Silicone . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .159<br />
Thermogreen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .159<br />
Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .173-178<br />
TotalChrom Data Handling Systems . . . . . . . . . . . . . . . . . . . . . . . . .173<br />
Intelligent Interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .174-175<br />
dotLINK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .174<br />
Integral Link . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .174<br />
NCI Intelligent Interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .174<br />
Power Cords 240 V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .175<br />
Alphabetical Gas Chromatography Index<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
433
Gas Chromatography Index<br />
Alphabetical<br />
Gas Chromatography Index Alphabetical<br />
SoftLINK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .175<br />
Interface Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .176<br />
Interface Personality Modules (IPM) . . . . . . . . . . . . . . . . . . . . . .176<br />
Interface Validation Modules (IVM) . . . . . . . . . . . . . . . . . . . . . . .176<br />
Serial Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .177<br />
IEEE Cables – All TC Versions . . . . . . . . . . . . . . . . . . . . . . . . . .177<br />
TotalChrom TM WS and C/S Serial Cables<br />
to Lantronix Terminal Server . . . . . . . . . . . . . . . . . . . . . . . . . . .177<br />
TotalChrom WS and C/S Serial Cables to PC . . . . . . . . . . . . . . .177<br />
Serial Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .177<br />
Software Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .178<br />
Serial Communications CArds for TurboChrom . . . . . . . . . . . . . .178<br />
TotalChrom Workstation Manuals . . . . . . . . . . . . . . . . . . . . . . . .178<br />
TotalChrom Workstation SI/DI Upgrade Kits . . . . . . . . . . . . . . . . .178<br />
TotalChrom Workstation Software . . . . . . . . . . . . . . . . . . . . . . . .178<br />
Syringes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .161-162<br />
Autosampler Syringes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .161<br />
Needle Syringes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .161-162<br />
Fixed Needle Syringes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .161<br />
Gas Tight Syringes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .162<br />
Removable Needle Syringes . . . . . . . . . . . . . . . . . . . . . . . . . . .161<br />
Ultramicro Volume Syringes . . . . . . . . . . . . . . . . . . . . . . . . . . . .162<br />
Thermal Desorbers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .179-184<br />
Ozone Precursor Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .180<br />
Air Toxics Columns . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .180<br />
Model STS 25 Sequential Tube Sampler . . . . . . . . . . . . . . . . . . .180<br />
Model STS 25 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . .180<br />
Ozone Precursor Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . .180<br />
Sample Tubes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .181<br />
Caps for TurboMatrix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .181<br />
Repalcement Parts for ATD 400 Tube Seal and Tube . . . . . . . . . .181<br />
Sample Tubes for TurboMatrix . . . . . . . . . . . . . . . . . . . . . . . . . .181<br />
Thermal Desorber Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . .182-184<br />
Cold Traps, Fittings, and Accessories . . . . . . . . . . . . . . . . . . . . .182<br />
Consumables Starter Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .182<br />
Gauze Loading Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .182<br />
Interface Cables for ATD 400 . . . . . . . . . . . . . . . . . . . . . . . . . . .182<br />
Interface Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .182-183<br />
Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .183<br />
Miscellaneous Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . .183<br />
Mobile Seal Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .183<br />
Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .183<br />
Trap Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .183-184<br />
TurboMatrix Upgrade Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . .184<br />
TurboMatrix Upper Seal Assembly . . . . . . . . . . . . . . . . . . . . . . .184<br />
Valves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .170-172<br />
Valve Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .170-172<br />
Adapters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .170<br />
Air Acuators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .170<br />
Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .171<br />
Standoffs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .171<br />
Valve Fittings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .172<br />
Vials . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .88-90, 148-149<br />
Autosampler Vials . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .88-89<br />
Autosampler Starter Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .88<br />
Crimp Top Sample Vials and Caps . . . . . . . . . . . . . . . . . . . . . . . .89<br />
Screw Top Sample Vials and Caps . . . . . . . . . . . . . . . . . . . . . . . .89<br />
Crimping Tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .90, 149<br />
11 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .90<br />
20 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .149<br />
Headspace Vials . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .148<br />
Crimp Caps and Septa . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .148<br />
Safety Sample Vials . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .148<br />
434
Inductively Coupled Plasma – MS Index<br />
Alphabetical<br />
Autosampler Supplies and Accessories . . . . . . . . . . . . . . . . .8-10, 188<br />
Autosampler Flame/FIAS Probes . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9<br />
Autosampler Flame/FIAS Trays and Vessels . . . . . . . . . . . . . . . . . . . . .8<br />
Dilution System Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10<br />
Gilson 222 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .188<br />
UltraClean Sampling Probes and Accessories . . . . . . . . . . . . . . . . . .188<br />
Chillers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .189<br />
Chromera Speciation Software . . . . . . . . . . . . . . . . . . . . . . . . . . . .207<br />
Cones . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .189<br />
Nickel Sampler and Skimmer Cones . . . . . . . . . . . . . . . . . . . . . . . . .189<br />
Platinum Sampler and Skimmer Cones . . . . . . . . . . . . . . . . . . . . . . .189<br />
Cooling Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .189<br />
Chillers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .189<br />
Heat Exchanger Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .189<br />
Detectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .190<br />
ELAN Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .206<br />
Flow Injection Sampling Supplies . . . . . . . . . . . . . . . . . . . .21-28, 188<br />
FIAS and FIMS Parts and Supplies . . . . . . . . . . . . . . . . . . . . . . . .22-23<br />
FIAS and FIMS Tubing Adapters and Connectors . . . . . . . . . . . . . . . . .24<br />
FIAS and FIMS Tubing and Supplies . . . . . . . . . . . . . . . . . . . . . . . . . .25<br />
FIAS-400MS Supplies and Accessories . . . . . . . . . . . . . . . . . . . . . .188<br />
Flow Injection Amalgamation System . . . . . . . . . . . . . . . . . . . . . . . . .26<br />
Flow Injection Analysis and Mercury Systems . . . . . . . . . . . . . . . . . . .21<br />
Flow Injection Furnace Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27<br />
Flow Injection Preconcentration Kit and Supplies . . . . . . . . . . . . . . . . .28<br />
Heat Exchanger Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .189<br />
Injector Support Adapters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .195<br />
Injectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .194-195<br />
Alumina Injectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .194<br />
PFA Injector Assemblies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .194<br />
Quartz Injectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .195<br />
Sapphire Injector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .195<br />
Ion Optics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .190<br />
Ion Lenses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .190<br />
ShadowStops . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .190<br />
Mass Flow Controllers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .191<br />
Mass Spectrometer Hardware . . . . . . . . . . . . . . . . . . . . . . . . .189-192<br />
Cones and Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .189<br />
Nickel Sampler and Skimmer Cones . . . . . . . . . . . . . . . . . . . . .189<br />
Platinum Sampler and Skimmer Cones . . . . . . . . . . . . . . . . . . .189<br />
Cooling Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .189<br />
Chillers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .189<br />
Heat Exchangers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .189<br />
Detectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .190<br />
Ion Optics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .190<br />
Ion Lenses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .190<br />
ShadowStops . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .190<br />
Mass Flow Controllers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .191<br />
Reaction Gas Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .192<br />
DRC Gas Cabinets and Upgrade Kits . . . . . . . . . . . . . . . . . . . . .192<br />
Second Reaction Gas Pneumatics . . . . . . . . . . . . . . . . . . . . . . .192<br />
Vacuum Pumps and Accessories . . . . . . . . . . . . . . . . . . . . . . . .192<br />
Nebulizers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .196-199<br />
Concentric Nebulizers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .196-197<br />
MEINHARD Nebulizers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .196<br />
MicroMist Nebulizers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .197<br />
SeaSpray Nebulizers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .197<br />
Teflon PFA Nebulizers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .196<br />
GemClean Cross-Flow II Nebulizer . . . . . . . . . . . . . . . . . . . . . . . . . .197<br />
Microconcentric Nebulizers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .198<br />
Ultrasonic Nebulizers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .199<br />
Peristaltic Pump Tubing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .199<br />
Reaction Gas Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .192<br />
DRC Gas Cabinets and Upgrade Kits . . . . . . . . . . . . . . . . . . . . . . . .192<br />
Second Reaction Gas Pneumatics . . . . . . . . . . . . . . . . . . . . . . . . . .192<br />
Vacuum Pumps and Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . .192<br />
Sample Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .193-205<br />
Consumables Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .193<br />
Graphite Furnace Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .193<br />
HGA – 600MS Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .193<br />
Injector Support Adapters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .195<br />
Injectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .194-195<br />
Alumina Injectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .194<br />
PFA Injector Assemblies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .194<br />
Quartz Injectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .195<br />
Sapphire Injector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .195<br />
Nebulizers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .196-199<br />
Concentric Nebulizers . . . . . . . . . . . . . . . . . . . . . . . . . . . .196-197<br />
GemClean Cross-Flow II Nebulizer . . . . . . . . . . . . . . . . . . . . . . .197<br />
GemClean Cross-Flow II Nebulizer Replacement Parts . . . . . . . . .198<br />
Microconcentric Nebulizers . . . . . . . . . . . . . . . . . . . . . . . . . . . .198<br />
Ultrasonic Nebulizers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .199<br />
Peristaltic Pump Supplies and Accessories . . . . . . . . . . . . . . . . . . . .199<br />
Gilson Peristaltic Pump and Accessories . . . . . . . . . . . . . . . . . .199<br />
Peristaltic Pump Tubing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .199<br />
Sample Introduction Systems and Replacement Parts . . . . . . . .200-201<br />
Organic Sampling Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . .200<br />
Replacement Parts for Twist Type Torch Models . . . . . . . . . . . . .201<br />
Sample Introduction Systems . . . . . . . . . . . . . . . . . . . . . . . . . . .200<br />
Spray Chambers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .202-204<br />
Baffled Cyclonic Spray Chambers . . . . . . . . . . . . . . . . . . . . . . .202<br />
Cyclonic Spray Chamber . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .203<br />
Drain Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .204<br />
PFA Teflon Spray Chamber . . . . . . . . . . . . . . . . . . . . . . . . . . . .204<br />
Scott Spray Chamber . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .204<br />
Torches and Torch Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . .205<br />
RF Coils . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .205<br />
Torches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .205<br />
Sample Introduction Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . .200<br />
HF-Resistant Sample Introduction System . . . . . . . . . . . . . . . . . . . . .200<br />
Organic Sample Introduction Systems . . . . . . . . . . . . . . . . . . . . . . .200<br />
Heavy Organic Sample Introduction System . . . . . . . . . . . . . . . .200<br />
Peltier Cooled Organic Sample Introduction System . . . . . . . . . .200<br />
PFA Teflon Sample Introduction Systems . . . . . . . . . . . . . . . . . . . . .200<br />
Sample Preparation Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . .53-64<br />
Multiwave 3000 Accessories and Supplies . . . . . . . . . . . . . . . . . .56-64<br />
Multiwave Accessories and Supplies . . . . . . . . . . . . . . . . . . . . . . .53-55<br />
Software for ICP-MS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .206<br />
ICP-MS Operating System and Application Software . . . . . . . . . . . . .206<br />
ELAN Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .206<br />
Alphabetical Inductively Coupled Plasma – MS Index<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
435
Inductively Coupled Plasma – MS Index<br />
Alphabetical<br />
Speciation by Chromatography . . . . . . . . . . . . . . . . . . . . . . . .207-208<br />
Speciation Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .207-208<br />
Chromera Speciation Software . . . . . . . . . . . . . . . . . . . . . . . . . .207<br />
HPLC Columns for Speciation . . . . . . . . . . . . . . . . . . . . . . . . . .207<br />
Speciation Accessories and Supplies . . . . . . . . . . . . . . . . . . . . .208<br />
Speciation Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .208<br />
Spray Chambers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .202-204<br />
Baffled Cyclonic Spray Chambers . . . . . . . . . . . . . . . . . . . . . . . . . . .202<br />
Cyclonic Spray Chamber . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .203<br />
PFA Teflon Spray Chamber . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .204<br />
Scott Spray Chamber . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .204<br />
Inductively Coupled Plasma – MS Index Alphabetical<br />
Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .209-212<br />
PerkinElmer Pure Plus Standards for ICP-MS . . . . . . . . . . . . . .209-212<br />
Detection Limit Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . .210<br />
Instrument Calibration Standards . . . . . . . . . . . . . . . . . . . . . . . .210<br />
Multi-Element Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .211<br />
Performance Verification Standards . . . . . . . . . . . . . . . . . . . . . .212<br />
Smart Tune Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .212<br />
Wash Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .212<br />
Torches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .205<br />
Cassette Torch Mount . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .205<br />
Demountable Quartz Torch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .205<br />
High Efficiency Demountable Quartz Torch . . . . . . . . . . . . . . . . . . . .205<br />
Vacuum Pump Oil . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .192<br />
436
Inductively Coupled Plasma – OES Index<br />
Alphabetical<br />
Accessories for ICP–OES . . . . . . . . . . . . . . . . . . . . . . . . . . . . .216-217<br />
Laboratory Products . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .216-217<br />
Air and Gas Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .216<br />
Blower and Vent Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . .217<br />
Cooling Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .217<br />
Autosampler Supplies and Accessories . . . . . . . . . . . . . . . . . . . . .8-10<br />
Autosampler Flame/FIAS Probes . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9<br />
Autosampler Flame/FIAS Trays and Vessels . . . . . . . . . . . . . . . . . . . . .8<br />
Dilution System Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10<br />
Chillers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .217<br />
Cooling Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .217<br />
Chillers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .217<br />
Flow Injection Sampling Supplies . . . . . . . . . . . . . . . . . . . . . . . .21-28<br />
FIAS and FIMS Parts and Supplies . . . . . . . . . . . . . . . . . . . . . . . .22-23<br />
FIAS and FIMS Tubing Adapters and Connectors . . . . . . . . . . . . . . . . .24<br />
FIAS and FIMS Tubing and Supplies . . . . . . . . . . . . . . . . . . . . . . . . . .25<br />
Flow Injection Amalgamation System . . . . . . . . . . . . . . . . . . . . . . . . .26<br />
Flow Injection Analysis and Mercury Systems . . . . . . . . . . . . . . . . . . .21<br />
Flow Injection Furnace Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27<br />
Flow Injection Preconcentration Kit and Supplies . . . . . . . . . . . . . . . . .28<br />
Injector Support Adapters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .220<br />
Injectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .220<br />
Alumina Injectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .220<br />
Quartz Injectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .220<br />
Sapphire Injectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .220<br />
Nebulizers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .221-223<br />
Concentric Nebulizers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .221-222<br />
MEINHARD Nebulizers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .221<br />
MicroMist Nebulizers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .221<br />
PEEK Mira Mist Nebulizer . . . . . . . . . . . . . . . . . . . . . . . . . . . . .222<br />
SeaSpray Nebulizers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .222<br />
GemCone Nebulizers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .222<br />
GemTip Crossflow Nebulizer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .223<br />
Ultrasonic Nebulizer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .221<br />
Peristaltic Pump Tubing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .224<br />
Sample Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .218-230<br />
Accessories for Sample Introduction . . . . . . . . . . . . . . . . . . . . .218-219<br />
Drain Assembly Components . . . . . . . . . . . . . . . . . . . . . . . . . . .218<br />
Protective and Cleaning Accessories . . . . . . . . . . . . . . . . . . . . .218<br />
Purge Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .219<br />
RF Load Coils . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .219<br />
Injectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .220<br />
Alumina Injectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .220<br />
Quartz Injectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .220<br />
Sapphire Injectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .220<br />
Injector Support Adapters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .220<br />
Nebulizers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .221-223<br />
CETAC Ultrasonic Nebulizer . . . . . . . . . . . . . . . . . . . . . . . . . . . .221<br />
Concentric Nebulizers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .221<br />
GemCone Nebulizer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .222<br />
GemTip Crossflow Nebulizer . . . . . . . . . . . . . . . . . . . . . . . . . . .223<br />
Peristaltic Pump Supplies and Accessories . . . . . . . . . . . . . . . . . . . .224<br />
Peristaltic Pump . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .224<br />
Peristaltic Pump Tubing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .224<br />
Spray Chambers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .225-226<br />
Cyclonic Spray Chamber . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .225<br />
Ryton Scott Spray Chamber and Replacement Parts . . . . . . . . . .226<br />
Torches and Torch Accessories . . . . . . . . . . . . . . . . . . . . . . . . .227-230<br />
Torch Bonnets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .227<br />
Torch Modules and Assemblies . . . . . . . . . . . . . . . . . . . . . . . . .227<br />
Torch Replacement Parts . . . . . . . . . . . . . . . . . . . . . . . . . .228-230<br />
Torches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .227<br />
Sample Preparation Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . .50-64<br />
High Pressure Asher System Supplies . . . . . . . . . . . . . . . . . . . . . .50-52<br />
Multiwave 3000 Accessories and Supplies . . . . . . . . . . . . . . . . . .56-64<br />
Multiwave Accessories and Supplies . . . . . . . . . . . . . . . . . . . . . . .53-55<br />
Spray Chambers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .225-226<br />
Baffled Cyclonic Spray Chambers . . . . . . . . . . . . . . . . . . . . . . . . . . .225<br />
Cyclonic Spray Chamber . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .225<br />
Ryton Scott Spray Chamber . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .226<br />
Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .231-236<br />
PerkinElmer Pure Standards for ICP-OES . . . . . . . . . . . . . . . . .231-236<br />
Alternate Trace Metal Drinking Water<br />
and Wastewater Pollution Standards . . . . . . . . . . . . . . . . . . . . .232<br />
Contract Required Detection Limits (CRDL) Standard . . . . . . . . . .232<br />
Drinking Water Pollutant Standards . . . . . . . . . . . . . . . . . . . . . .232<br />
Groundwater and Wastewater Pollution Control Check Standards 233<br />
Instrument Calibration Standards . . . . . . . . . . . . . . . . . . . . . . . .233<br />
Interference Check Standards . . . . . . . . . . . . . . . . . . . . . . . . . .233<br />
Multi-Element Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .234<br />
Quality Control Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . .235<br />
Wavecal Solutions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .236<br />
Torches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .227-228<br />
Demountable Quartz Torch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .227<br />
Quick-Change Torch Modules . . . . . . . . . . . . . . . . . . . . . . . . . .227-228<br />
Alphabetical Inductively Coupled Plasma – OES Index<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
437
Infrared Spectroscopy Index<br />
Alphabetical<br />
Infrared Spectroscopy Index Alphabetical<br />
Autosampler Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .242-244<br />
Desiccant Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .240<br />
Evacuable<br />
Potassium Bromide Die . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .258<br />
Gas Sampling Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .245<br />
Hydraulic Press . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .258<br />
KBr Pellet Mini-press . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .259<br />
KBr Pellet Quick Press . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .259<br />
Laboratory Products . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .240-241<br />
Beamsplitters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .240<br />
Desiccant Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .240<br />
Maintenance Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .240<br />
Source Lamps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .241<br />
Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .241<br />
TG/IR and GC/IR Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .241<br />
Liquid Sampling Cells and Supplies . . . . . . . . . . . . . . . . . . . . .248-251<br />
Demountable Cells and Windows . . . . . . . . . . . . . . . . . . . . . . . . . . .248<br />
FT-NIR Cells and Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .249<br />
FT-NIR Disposable Cells and Holders<br />
for the Spectrum One NTS/100N . . . . . . . . . . . . . . . . . . . . . . . . . . .249<br />
Press-N-Lock Demountable Cell and Windows . . . . . . . . . . . . . . . . .250<br />
Sealed Liquid Cells . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .250<br />
Semi-demountable Cells and Windows . . . . . . . . . . . . . . . . . . . . . . .251<br />
Microscopy Sampling Accessories and Supplies . . . . . . . . . . .252-254<br />
Reflectance Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . .255-256<br />
Diffuse Reflectance Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . .255<br />
FT-NIR Reflectance Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . .256<br />
Horizontal Attenuated Total Reflectance (HATR) Accessories . . . . . . . .255<br />
Specular Reflectance Accessories . . . . . . . . . . . . . . . . . . . . . . . . . .256<br />
Universal Attenuated Total Reflectance (ATR) Accessories . . . . . . . . .256<br />
Sampling Accessories and Supplies . . . . . . . . . . . . . . . . . . . .242-260<br />
Autosampler Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .242-244<br />
Autosampler Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .242<br />
Autosampler Flowcells, Windows, and Supplies . . . . . . . . . . . . .242<br />
Autosampler Sample Cassettes<br />
and Vials for FT-IR and FT-NIR . . . . . . . . . . . . . . . . . . . . . . . . . .242<br />
Autosampler Sample Racks for Spectrum OilExpress . . . . . . . . .243<br />
Autosampler Syringe and Needle Supplies . . . . . . . . . . . . . . . . .243<br />
Autosampler Tubing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .243<br />
Tablet Autosampler Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . .244<br />
Gas Sampling Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .245<br />
Short-path Demountable Gas Cells and Windows . . . . . . . . . . . .245<br />
Liquid Sampling Cells and Supplies . . . . . . . . . . . . . . . . . . . . . .246-251<br />
Crystal Polishing Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .248<br />
Demountable Cells and Windows . . . . . . . . . . . . . . . . . . . . . . . .248<br />
FT-NIR Cells and Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . .249<br />
FT-NIR Disposable Cells and Holders<br />
for the Spectrum One NTS/100N . . . . . . . . . . . . . . . . . . . . . . . .249<br />
Press-N-Lock Demountable Cell and Windows . . . . . . . . . . . . . .250<br />
Sealed Liquid Cells . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .250<br />
Semi-demountable Cells and Windows . . . . . . . . . . . . . . . . . . . .251<br />
Microscopy Sampling Accessories and Supplies . . . . . . . . . . . .252-254<br />
Beam Condensers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .252<br />
Microsampling Tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .253<br />
Rotatable Cell Holder and Microscope Supplies . . . . . . . . . . . . .253<br />
Sampling Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .254<br />
Reflectance Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .255-256<br />
Diffuse Reflectance Accessories . . . . . . . . . . . . . . . . . . . . . . . . .255<br />
FT-NIR Reflectance Accessories . . . . . . . . . . . . . . . . . . . . . . . . .256<br />
Horizontal Attenuated Total Reflectance (HATR) Accessories . . . . .255<br />
Specular Reflectance Accessories . . . . . . . . . . . . . . . . . . . . . . .256<br />
Universal Attenuated Total Reflectance (ATR) Accessories . . . . . .256<br />
Sampling Kits and Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .257<br />
FT-IR Sampling Kit Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . .257<br />
FT-IR Sampling Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .257<br />
Sipper Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .244<br />
Sipper Cells and Windows for the Spectrum One/100 . . . . . . . . .244<br />
Sipper Cells and Windows for the Spectrum One NTS/100N . . . .244<br />
Sipper Pump Tubing and Supplies . . . . . . . . . . . . . . . . . . . . . . .244<br />
Solid Sampling Accessories and Supplies . . . . . . . . . . . . . . . . .258-260<br />
Evacuable Potassium Bromide Die . . . . . . . . . . . . . . . . . . . . . . .258<br />
Hydraulic Press . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .258<br />
KBr Pellet Mini-press . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .259<br />
KBr Pellet Quick Press . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .259<br />
Polarizers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .259<br />
Remote Sampling System Accessories . . . . . . . . . . . . . . . . . . . .260<br />
Sample Holders and Film Mounts . . . . . . . . . . . . . . . . . . . . . . . .260<br />
Sipper Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .244<br />
Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .261-264<br />
Spectrum Infrared Software . . . . . . . . . . . . . . . . . . . . . . . . . . .261-264<br />
Application Software Packages . . . . . . . . . . . . . . . . . . . . . . . . .261<br />
AutoIMAGE Upgrades . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .262<br />
Spectrum One Enhanced Security Software Upgrades . . . . . . . . .264<br />
Spectrum One Software Upgrades . . . . . . . . . . . . . . . . . . . . . . .263<br />
Spectrum One/100 AssureID<br />
Upgrades and Validation Suite . . . . . . . . . . . . . . . . . . . . . . . . . .262<br />
Solid Sampling Accessories and Supplies . . . . . . . . . . . . . . . .258-260<br />
Hydraulic Press and Evacuable<br />
Potassium Bromide Die . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .258<br />
KBr Pellet Mini-press . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .259<br />
KBr Pellet Quick Press . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .259<br />
Polarizers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .259<br />
Remote Sampling System Accessories . . . . . . . . . . . . . . . . . . . . . . .260<br />
Sample Holders and Film Mounts . . . . . . . . . . . . . . . . . . . . . . . . . . .260<br />
Spectrum One Enhanced<br />
Security Software Upgrades . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .264<br />
Spectrum One Software Upgrades . . . . . . . . . . . . . . . . . . . . . . . . .263<br />
Upgrade Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .265<br />
Detector Upgrades . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .265<br />
Microscope Upgrades . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .265<br />
Spectrum One/100 Upgrades . . . . . . . . . . . . . . . . . . . . . . . . . . . . .265<br />
438
Liquid Chromatography Index<br />
Alphabetical<br />
Autosampler Supplies and Accessories . . . . . . . . . . . . . . . . . .270-273<br />
Autosampler Trays and Plates . . . . . . . . . . . . . . . . . . . . . . . . . . . . .270<br />
Peltier Tray Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .270<br />
Sample Trays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .270<br />
Series 200 Autosampler Microtiter Trays and Plates . . . . . . . . . .270<br />
Autosampler Vial Crimping Tools . . . . . . . . . . . . . . . . . . . . . . . . . . .272<br />
Crimpers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .272<br />
Autosampler Vials and Caps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .271<br />
0.2 mL Micro Vials,<br />
Caps, and Septa . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .271<br />
2.0 mL Vials, Caps and Septa . . . . . . . . . . . . . . . . . . . . . . . . . .271<br />
6 mL Vials and Caps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .271<br />
Compatibility Table for Vials and Caps in Sample Trays . . . . . . . .271<br />
ISS-200 and Series 200 Autosampler . . . . . . . . . . . . . . . . . . . . . . .273<br />
Autosampler Syringes Series 200 . . . . . . . . . . . . . . . . . . . . . . .273<br />
BCD Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .273<br />
ISS-200 Injector Valve Parts for BSW Valves . . . . . . . . . . . . . . . .273<br />
ISS-200 Sample Trays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .273<br />
ISS-200 Spares . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .273<br />
Manuals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .273<br />
Replacement Parts Series 200 . . . . . . . . . . . . . . . . . . . . . . . . .273<br />
Cartridge Column Applications . . . . . . . . . . . . . . . . . . . . . . . . .276-284<br />
Biotechnology Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .277<br />
Clinical and Environmental Applications . . . . . . . . . . . . . . . . . . . . . .278<br />
Column Application Notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .276<br />
Food Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .279-280<br />
Industrial Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .281<br />
Pharmaceutical Applications . . . . . . . . . . . . . . . . . . . . . . . . . . .282-284<br />
Cartridge Columns . . . . . . . . . . . . . . . . . . . . . . . . . .274-275, 285-293<br />
Brownlee CHOICE Columns for LC/MS . . . . . . . . . . . . . . . . . . . . . . .285<br />
CHOICE Columns . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .285<br />
Columns for LC/MS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .285<br />
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .285<br />
Brownlee Cartridge Column Selection and Specification Guide . . . . . .275<br />
Brownlee Cartridge Columns . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .274<br />
Brownlee MPLC Columns . . . . . . . . . . . . . . . . . . . . . . . . . . . . .286-287<br />
Ion Exchange . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .286-287<br />
Polar Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .286-287<br />
Reversed Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .286-287<br />
Brownlee Peco Fast LC Columns . . . . . . . . . . . . . . . . . . . . . . .288-289<br />
Normal Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .289<br />
Reversed Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .289<br />
Scavenger Columns . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .289<br />
Brownlee Preparative and VeloSep Columns . . . . . . . . . . . . . . . . . . .290<br />
Brownlee Preparative Columns . . . . . . . . . . . . . . . . . . . . . . . . .290<br />
Brownlee VeloSep Columns . . . . . . . . . . . . . . . . . . . . . . . . . . . .290<br />
Brownlee Validated MPLC Columns . . . . . . . . . . . . . . . . . . . . . . . . .291<br />
Brownlee Validated Columns . . . . . . . . . . . . . . . . . . . . . . . . . . .291<br />
Guard Cartridge Columns and Accessories . . . . . . . . . . . . . . . . . . . .292<br />
NewGuard Columns . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .292<br />
Replacement Seals for MPLC and Prep-10 Holders . . . . . . . . . .292<br />
Standards Solutions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .292<br />
Holders and Accessories for Cartridge Columns . . . . . . . . . . . . . . . .293<br />
MPLC/PecoTM Holders . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .293<br />
Prep-10 Cartridge Holders . . . . . . . . . . . . . . . . . . . . . . . . . . . . .293<br />
Check Valves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .319<br />
Conventional Column Applications . . . . . . . . . . . . . . . . . . . . . .297-307<br />
Biochemical . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .297-298<br />
Dietary Supplements/Plant Extracts . . . . . . . . . . . . . . . . . . . . . . . . .299<br />
Environmental . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .300-303<br />
Food and Flavors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .304<br />
Pharmaceutical . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .305-307<br />
Conventional Columns . . . . . . . . . . . . . . . . . . . . . . .294-296, 308-313<br />
Brownlee Validated Conventional Columns . . . . . . . . . . . . . . . . . . . .312<br />
Brownlee Validated Cyano . . . . . . . . . . . . . . . . . . . . . . . . . . . . .312<br />
Brownlee Validated IBD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .312<br />
Brownlee Validated PFP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .312<br />
Brownlee Validated Phenyl . . . . . . . . . . . . . . . . . . . . . . . . . . . . .312<br />
Brownlee ValidatedTM Carbamate . . . . . . . . . . . . . . . . . . . . . . .312<br />
Brownlee Analytical Conventional Columns . . . . . . . . . . . . . . . . . . . .308<br />
Brownlee Analytical Amino . . . . . . . . . . . . . . . . . . . . . . . . . . . . .308<br />
Brownlee Analytical C18 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .308<br />
Brownlee Analytical C8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .308<br />
Brownlee Analytical Cyano . . . . . . . . . . . . . . . . . . . . . . . . . . . . .308<br />
Brownlee Analytical PAH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .308<br />
Brownlee Analytical Phenyl . . . . . . . . . . . . . . . . . . . . . . . . . . . .308<br />
Brownlee Analytical Silica . . . . . . . . . . . . . . . . . . . . . . . . . . . . .308<br />
Brownlee Aquapore and Bio Conventional Columns . . . . . . . . . . . . . .309<br />
Brownlee Aquapore AX-300 . . . . . . . . . . . . . . . . . . . . . . . . . . . .309<br />
Brownlee Aquapore ODS C18 . . . . . . . . . . . . . . . . . . . . . . . . . .309<br />
Brownlee Aquapore Octyl C8 . . . . . . . . . . . . . . . . . . . . . . . . . . .309<br />
Brownlee Bio C18 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .309<br />
Brownlee Bio C8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .309<br />
Brownlee CHOICE Conventional Columns . . . . . . . . . . . . . . . . . . . . .310<br />
Brownlee CHOICE Basix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .310<br />
Brownlee CHOICE C18 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .310<br />
Brownlee CHOICE Organic Acids . . . . . . . . . . . . . . . . . . . . . . . .310<br />
Brownlee CHOICE Propyl . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .310<br />
Brownlee Spheri-5 and Validated Conventional Columns . . . . . . . . . .311<br />
Brownlee Spheri-5 ® . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .311<br />
Brownlee Validated Aqueous C18 . . . . . . . . . . . . . . . . . . . . . . . .311<br />
Brownlee Validated C1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .311<br />
Brownlee Validated C18 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .311<br />
Brownlee Validated C4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .311<br />
Brownlee Validated C8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .311<br />
Brownlee ValidatedTM Amino . . . . . . . . . . . . . . . . . . . . . . . . . . .311<br />
Conventional Column Applications . . . . . . . . . . . . . . . . . . . . . . . . . .296<br />
Conventional Columns Selection and Specification Guide . . . . . . . . . .295<br />
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .295<br />
Guard Cartridges and Accessories . . . . . . . . . . . . . . . . . . . . . . . . . .313<br />
Guard Cartridge Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . .313<br />
Guard Cartridges Brownlee Analytical . . . . . . . . . . . . . . . . . . . . .313<br />
Guard Cartridges Brownlee Bio . . . . . . . . . . . . . . . . . . . . . . . . .313<br />
Guard Cartridges Brownlee CHOICE . . . . . . . . . . . . . . . . . . . . . .313<br />
Guard Cartridges Brownlee Validated . . . . . . . . . . . . . . . . . . . . .313<br />
Degassing Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .318<br />
200 Series On-line . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .318<br />
Helium . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .318<br />
System Spares . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .318<br />
Detectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .314-316<br />
Diode Array Detector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .314<br />
LC-135C/235 Detector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .314<br />
Series 200 Diode Array Detector . . . . . . . . . . . . . . . . . . . . . . . .314<br />
Fluorescence and Refractive Index (RI) Detector . . . . . . . . . . . . . . . .315<br />
LC-240 FL Detector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .315<br />
Series 200 Fluorescence Detector . . . . . . . . . . . . . . . . . . . . . . .315<br />
Series 200a RI Detector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .315<br />
UV/Visible Detector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .316<br />
Series 200/785A UV/VIS<br />
Detector Source Lamps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .316<br />
Series 200/785A UV/VIS<br />
Flowcells/Flowcell . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .316<br />
Series 200/785A UV/VIS<br />
Manuals/Maintenance Items . . . . . . . . . . . . . . . . . . . . . . . . . . .316<br />
Alphabetical Liquid Chromatography Index<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
439
Liquid Chromatography Index<br />
Alphabetical<br />
Filters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .327<br />
Filters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .327<br />
Fittings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .323<br />
PEEK Fingertight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .323<br />
Microtiter Trays and Plates . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .270<br />
Mixers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .321<br />
Dynamic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .321<br />
Static . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .321<br />
Serial Cables to PC from<br />
TotalChrom Interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .331<br />
TotalChrom Software Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .332<br />
TotalChrom Optional Software . . . . . . . . . . . . . . . . . . . . . . . . . .332<br />
TotalChrom Workstation<br />
SI/DI Upgrade Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .332<br />
TotalChrom Workstation Manuals . . . . . . . . . . . . . . . . . . . . . . . .332<br />
Standard Solutions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .292<br />
Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .292<br />
Test Mix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .292<br />
Liquid Chromatography Index Alphabetical<br />
Ovens . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .317<br />
LC Column Ovens . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .317<br />
Series 200 Ovens . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .317<br />
Peltier Trays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .270<br />
100 Position . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .270<br />
Double Micrtiter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .270<br />
Peltier Temperature Controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . .270<br />
Pistons . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .319<br />
Piston Seals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .319<br />
Pistons . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .319<br />
Pumps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .318-322<br />
Degassing Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .318<br />
200 Series On-line<br />
Vacuum Degasser Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .318<br />
Degassing Kits - Helium . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .318<br />
Degassing System Spares - Helium . . . . . . . . . . . . . . . . . . . . . .318<br />
Supply Connectors - Helium . . . . . . . . . . . . . . . . . . . . . . . . . . .318<br />
Piston and Piston Accessories . . . . . . . . . . . . . . . . . . . . . . . . .319-320<br />
Check Valves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .319<br />
Piston Seals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .319<br />
Pistons . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .319<br />
Seals, Pistons, and Check Valves . . . . . . . . . . . . . . . . . . . . . . . .320<br />
Pump Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .321<br />
Bio Conversion Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .321<br />
Maintenance Kits and Tools . . . . . . . . . . . . . . . . . . . . . . . . . . . .321<br />
Manuals and Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . .321<br />
Mixers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .321<br />
Pulse Compensators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .321<br />
Series 200 Pump Solvent Upgrade Kits . . . . . . . . . . . . . . . . . . .321<br />
Solvent Filters and Spargers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .322<br />
Solvent Filters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .322<br />
Solvent Spargers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .322<br />
Sample Loops . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .326<br />
Internal Loop . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .326<br />
PEEK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .326<br />
Stainless Steel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .326<br />
Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .329-332<br />
Intelligent Interfaces for TotalChrom . . . . . . . . . . . . . . . . . . . . . . . . .329<br />
NCI Intelligent Interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .329<br />
dotLINK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .329<br />
Interface Modules for TotalChrom . . . . . . . . . . . . . . . . . . . . . . . . . . .330<br />
Interface Personality Modules (IPM) . . . . . . . . . . . . . . . . . . . . . .330<br />
Interface Validation Modules (IVM) . . . . . . . . . . . . . . . . . . . . . . .330<br />
Power Cords – 240 V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .330<br />
Serial Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .331<br />
IEEE Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .331<br />
Serial Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .331<br />
Serial Cables to Lantronix<br />
Terminal Server from<br />
TotalChrom Interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .331<br />
Supplies and Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . .323-327<br />
Fittings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .323<br />
Fittings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .323<br />
Fittings Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .323<br />
PEEK Union . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .323<br />
PEEK One-Piece FingertightTM Fittings . . . . . . . . . . . . . . . . . . .323<br />
Rheodyne Injection Valves . . . . . . . . . . . . . . . . . . . . . . . . . . . .324-325<br />
Rheodyne 7010 Injection Valve . . . . . . . . . . . . . . . . . . . . . . . . .324<br />
Rheodyne 7725 Injection Valve . . . . . . . . . . . . . . . . . . . . . . . . .324<br />
Rheodyne 8125 Low-Dispersion Stainless Steel Injection Valve . .324<br />
Rheodyne 9725 PEEK Injection Valve . . . . . . . . . . . . . . . . . . . . .324<br />
Rheodyne Valves Spare Parts . . . . . . . . . . . . . . . . . . . . . . . . . . .325<br />
Rheodyne Sample Loops . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .326<br />
Internal Loop for Models 7725/9725 . . . . . . . . . . . . . . . . . . . . .326<br />
PEEK Sample Loops for Rheodyne Valves . . . . . . . . . . . . . . . . . .326<br />
Stainless Steel Sample Loops for Rheodyne Valves and Injectors .326<br />
Sample Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .327<br />
Microsyringes (For Manual Injection) . . . . . . . . . . . . . . . . . . . . .327<br />
PEEK Tubing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .327<br />
Solvent and Sample Filtration . . . . . . . . . . . . . . . . . . . . . . . . . .327<br />
Stainless Steel Tubing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .327<br />
Tubing Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .327<br />
Syringes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .272, 327<br />
Autosampler . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .272<br />
Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .327<br />
Tubing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .327<br />
PEEK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .327<br />
Stainless Steel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .327<br />
Valves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .324-325<br />
7010 Injection Valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .324<br />
7725 Injection Valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .324<br />
8125 Injection Valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .324<br />
9725 Injection Valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .324<br />
Spare Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .325<br />
Vials . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .271-272<br />
Autosampler . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .271-272<br />
Crimp Top . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .271<br />
Crimping Tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .272<br />
Micro . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .271<br />
Polyethylene . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .271<br />
Screw Top . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .271<br />
440
Thermal Analysis Index<br />
Alphabetical<br />
Autosampler Supplies and Accessories (DSC) . . . . . . . . . . . . . . . . .345<br />
Hangdown Wire Kits (TGA) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .371<br />
Calibration Reference Materials . . . . . . . . . . . . . . . .350, 353, 366-368<br />
Diamond DMA/TMA Calibration Reference Materials . . . . . . . . . . . . .366<br />
Diamond TG/DTA Calibration Reference Materials . . . . . . . . . . . . . . .367<br />
DSC Calibration Reference Materials . . . . . . . . . . . . . . . . . . . . . . . .350<br />
DTA Calibration Reference Materials . . . . . . . . . . . . . . . . . . . . . . . . .353<br />
TGA Calibration Reference Materials . . . . . . . . . . . . . . . . . . . . . . . .368<br />
Crimpers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .344<br />
DSC Supplies and Accessories . . . . . . . . . . . . . . . . . . . . . . . . .345-352<br />
Autosampler Supplies and Accessories . . . . . . . . . . . . . . . . . . . . . .345<br />
Diamond DSC, PYRIS 1 DSC Autosampler,<br />
and DSC 7 Robotic System Supplies and Accessories . . . . . . . . .345<br />
DSC High Pressure Cells and Accessories . . . . . . . . . . . . . . . . . . . .346<br />
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .346<br />
DSC High Pressure Cells . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .346<br />
Intracoolers and Subambient Accessories . . . . . . . . . . . . . . . . .347-348<br />
Intracooler Spares . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .347<br />
Intracoolers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .347<br />
Subambient Accessories for<br />
Diamond DSC/PYRIS 1 DSC . . . . . . . . . . . . . . . . . . . . . . . . . . . .347<br />
Subambient Accessories for DSC 7 . . . . . . . . . . . . . . . . . . . . . .348<br />
Subambient Accessories for<br />
PYRIS 6 DSC/DSC 6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .348<br />
Subambient Accessories for Sapphire DSC . . . . . . . . . . . . . . . . .348<br />
Photocalorimeter Accessories and Supplies . . . . . . . . . . . . . . . . . . .349<br />
Aluminum Capsules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .349<br />
Photocalorimeter Accessory<br />
Kit for Diamond DSC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .349<br />
Photocalorimeter Accessory<br />
Replacement Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .349<br />
Sample Holder Supplies and Calibration Reference Materials . . .350-351<br />
DSC Calibration Reference Materials . . . . . . . . . . . . . . . . . . . . .350<br />
DSC Flow-Through Cover Kits . . . . . . . . . . . . . . . . . . . . . . . . . .350<br />
Sample Holder Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .351<br />
Structure of Common Polymer Poster . . . . . . . . . . . . . . . . . . . . . . . .352<br />
DSC Sample Pans and Crimpers . . . . . . . . . . . . . . . . . . . . . . .336-344<br />
Autosampler Sample Pan and Covers . . . . . . . . . . . . . . . . . . . . . . . .338<br />
DSC Sample Pan Quick Reference . . . . . . . . . . . . . . . . . . . . . .336-337<br />
Aluminum . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .336<br />
Ceramic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .336<br />
Copper . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .337<br />
Gold . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .337<br />
Graphite . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .337<br />
Platinum . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .337<br />
Silver . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .337<br />
Stainless Steel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .337<br />
Titanium . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .337<br />
Hermetically Sealed Sample Pans (up to 3 bar) . . . . . . . . . . . . . . . . .339<br />
High Pressure Sample Pans (24 to 150 bar) . . . . . . . . . . . . . . . . . . .340<br />
Large Volume Pans (55 to 90 μL) and Photo DSC Sample Pans . . . . .341<br />
Large Volume Sample Pans (55 to 90 μL) . . . . . . . . . . . . . . . . .341<br />
Photo DSC Pans . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .341<br />
Open Sample Pans . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .342-343<br />
Universal Crimpers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .344<br />
Crimpers and Sealers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .344<br />
DTA Supplies and Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . .353<br />
DTA Calibration Reference Materials and Supplies . . . . . . . . . . . . . .353<br />
DTA 7 Only Supplies and Accessories . . . . . . . . . . . . . . . . . . . .353<br />
DTA 7 and DTA 1700 Supplies and Accessories . . . . . . . . . . . . .353<br />
DTA Calibration Reference Materials . . . . . . . . . . . . . . . . . . . . .353<br />
Gas Station . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .355<br />
High Pressure Cells and Accessories (DSC) . . . . . . . . . . . . . . . . . . .346<br />
Intracoolers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .347<br />
Laboratory Products and Accessories . . . . . . . . . . . . . . . . . . .354-355<br />
Purge Gas Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .354-355<br />
Filters and Traps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .354<br />
Flow Meters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .354<br />
Gas Cylinder<br />
Installation Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .354<br />
Gas Regulators and Accessories . . . . . . . . . . . . . . . . . . . . . . . .354<br />
Gas Selector Accessory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .355<br />
Gas Station for Thermal Analysis . . . . . . . . . . . . . . . . . . . . . . . .355<br />
Mechanical Analysis (DMA) . . . . . . . . . . . . . . . . . . . . . . . . . . .356-363<br />
3-Point Bending Measuring Systems . . . . . . . . . . . . . . . . . . . .356-357<br />
Diamond DMA Bending Measuring System . . . . . . . . . . . . . . . . .356<br />
DMA 7/DMA 7e 3-Point Bending System Replacement Parts . . .356<br />
DMA 7/DMA 7e Large Adjustable 3-Point/4-Point Bending Kit . . .356<br />
DMA 7/DMA 7e Measuring Parts for ASTM 5934-96 . . . . . . . . .356<br />
DMA 7/DMA 7e Quartz 3-Point Bending Measuring Systems<br />
and Replacement Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .357<br />
Bending/Dual Cantilever Measuring Systems . . . . . . . . . . . . . . . . . .358<br />
Diamond DMA Bending Measuring System/(Dual Cantilever) . . . .358<br />
DMA 7/DMA 7e Dual Cantilever Measuring System<br />
and Replacement Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .358<br />
Compression/Expansion Measuring Systems . . . . . . . . . . . . . . .359-361<br />
Diamond DMA Measuring System and Parts . . . . . . . . . . . . . . . .359<br />
DMA 7/DMA 7e Cup and Plate Kits . . . . . . . . . . . . . . . . . . . . . .359<br />
DMA 7/DMA 7e Parallel Plates with Tray Kits . . . . . . . . . . . . . . .359<br />
DMA 7/DMA 7e Parallel Plate Measuring System<br />
and Replacement Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .360<br />
DMA 7/DMA 7e Quartz Parallel Plate Measuring Systems<br />
and Replacement Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .361<br />
DMA 7/DMA 7e Sintered Parallel Plate Kits . . . . . . . . . . . . . . . .361<br />
Extension and Shear Analysis Measuring Systems . . . . . . . . . . .362-363<br />
Diamond DMA Extension Measuring System<br />
and Replacement Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .362<br />
DMA 7/DMA 7e Extension Measuring System<br />
and Replacement Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .362<br />
DMA 7/DMA 7e Quartz Extension Measuring System . . . . . . . . .363<br />
DMA 7/DMA 7e Quartz Extension Measuring System<br />
and Replacement Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .363<br />
Shear Measuring System for Diamond DMA . . . . . . . . . . . . . . . .363<br />
Mechanical Analysis (TMA) . . . . . . . . . . . . . . . . . . . . . . . . . . . .364-365<br />
TMA Measuring Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . .364-365<br />
Application Solutions with Multiple Probe Types . . . . . . . . . . . . .364<br />
Bending/Flexure Analysis Kits and Parts . . . . . . . . . . . . . . . . . . .364<br />
Dilatometer Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .364<br />
Extension Analysis Kit and Parts . . . . . . . . . . . . . . . . . . . . . . . . .365<br />
Sample Tubes and Cylinders . . . . . . . . . . . . . . . . . . . . . . . . . . .365<br />
TMA 7 Expansion/Compression/<br />
Penetration Quartz Probes . . . . . . . . . . . . . . . . . . . . . . . . . . . . .365<br />
Mechanical Analysis (TMA/DMA) . . . . . . . . . . . . . . . . . . . . . . . . . . .366<br />
Furnace Accessories, Reference Materials, and Supplies . . . . . . . . . .366<br />
Diamond DMA/TMA Calibration<br />
Reference Materials and Tools . . . . . . . . . . . . . . . . . . . . . . . . . .366<br />
Diamond DMA/TMA Furnace Tubes, Thermocouple,<br />
and Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .366<br />
DMA 7, DMA 7e, and TMA7 Reference Materials . . . . . . . . . . . .366<br />
DMA 7, DMA 7e, and TMA7 Thermocouples, Furnaces,<br />
and Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .366<br />
Alphabetical Thermal Analysis Index<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
441
Thermal Analysis Index<br />
Alphabetical<br />
Photocalorimeter Accessories and Supplies . . . . . . . . . . . . . . . . . .349<br />
Purge Gas Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .354-355<br />
Filters and Traps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .354<br />
Flow Meters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .354<br />
Gas Cylinder Installation Accessories . . . . . . . . . . . . . . . . . . . . . . . .354<br />
Gas Regulators and Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . .355<br />
Gas Station and Gas Selector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .355<br />
Sample Holder Supplies (DSC) . . . . . . . . . . . . . . . . . . . . . . . . .350-351<br />
Sample Pans and Covers (DSC) . . . . . . . . . . . . . . . . . . . . . . . .336-343<br />
Sample Pans and Covers (Diamond TG/DTA) . . . . . . . . . . . . . . . . . .367<br />
Thermal Analysis Index Alphabetical<br />
Sample Pans and Covers (TGA) . . . . . . . . . . . . . . . . . . . . . . . . . . . .372<br />
Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .373-374<br />
Subambient Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . .347-348<br />
TG/DTA Supplies and Accessories . . . . . . . . . . . . . . . . . . . . . . . . . .367<br />
Diamond TG/DTA Supplies and Accessories . . . . . . . . . . . . . . . . . . .367<br />
Calibration Reference Materials . . . . . . . . . . . . . . . . . . . . . . . . .367<br />
Furnace and Furnace Accessories . . . . . . . . . . . . . . . . . . . . . . .367<br />
Hyphenated Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .367<br />
In-Line Filter Trap for Diamond TG/DTA . . . . . . . . . . . . . . . . . . .367<br />
Sample Pans . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .367<br />
TGA Supplies and Accessories . . . . . . . . . . . . . . . . . . . . . . . . .368-372<br />
Calibration Reference Materials . . . . . . . . . . . . . . . . . . . . . . . . . . . .368<br />
Furnace and Furnace Accessories . . . . . . . . . . . . . . . . . . . . . . .369-370<br />
Conversion Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .369<br />
Furnace Accessories and Glassware<br />
for TGA Standard and High-Temperature . . . . . . . . . . . . . . . . . .369<br />
TGA Accessories and Supplies . . . . . . . . . . . . . . . . . . . . . . . . . .370<br />
Hangdown Wires, Sample Pans, and Supplies . . . . . . . . . . . . . .371-372<br />
Hangdown Wire Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .371<br />
Sample Pans, Covers, and Supplies . . . . . . . . . . . . . . . . . . . . . .372<br />
Thermal Analysis Software . . . . . . . . . . . . . . . . . . . . . . . . . . . .373-374<br />
PYRIS Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .373-374<br />
PYRIS Series Advanced Software . . . . . . . . . . . . . . . . . . . . . . . .373<br />
PYRIS Series TMA/DMA<br />
Advanced Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .374<br />
PYRIS Series Thermal<br />
Analysis Manager Software . . . . . . . . . . . . . . . . . . . . . . . . . . . .374<br />
Ultramicrobalance Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .375<br />
Weights, Forceps, Stirrups, and Pans . . . . . . . . . . . . . . . . . . . . . . . .375<br />
AD-6 Ultramicrobalance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .375<br />
442
UV Visible Index<br />
Alphabetical<br />
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8-9, 380-386<br />
Autosampler Supplies and Accessories for UV . . . . . . . . . . . . . . . . . .8-9<br />
Fiber Optics Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .380<br />
General Purpose Optical Bench Kits<br />
for the LAMBDA 6XX/8XX/9XX . . . . . . . . . . . . . . . . . . . . . . . . . . . . .380<br />
Integrating Sphere Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . .381<br />
Polarizer/Depolarizer Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . .382<br />
Polarizer/Depolarizer Crystals<br />
for the LAMBDA 6XX/8XX/9XX . . . . . . . . . . . . . . . . . . . . . . . . . .382<br />
Polarizer/Depolarizer and Accessories<br />
for the LAMBDA 6XX/8XX/9XX . . . . . . . . . . . . . . . . . . . . . . . . . .382<br />
Sipper Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .382-383<br />
Sipper Cells . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .383<br />
Sipper Tubing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .383<br />
Sippers and Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .382<br />
Specular Reflectance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .384<br />
Absolute Specular Reflectance Accessory . . . . . . . . . . . . . . . . . .384<br />
Accessories for Specular Reflectance . . . . . . . . . . . . . . . . . . . . .384<br />
Thermostatting Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . .385-386<br />
Research Peltier System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .386<br />
Routine Peltier Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .385<br />
Autosampler Supplies<br />
and Accessories for UV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8-9<br />
Calibration Reference Materials . . . . . . . . . . . . . . . . . . . . . . . .395-396<br />
Miscellaneous Calibration Materials . . . . . . . . . . . . . . . . . . . . . . . . .396<br />
Secondary Reference Materials . . . . . . . . . . . . . . . . . . . . . . . . . . . .395<br />
Spectralon Diffuse Color Reference Material . . . . . . . . . . . . . . . . . . .396<br />
Spectralon ® UV/Vis/NIR Diffuse<br />
Reflectance Reference Material . . . . . . . . . . . . . . . . . . . . . . . . . . . .396<br />
Cells . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .387-394<br />
Cell Changers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .387-388<br />
Cell Changers for LAMBDA 1X/2X/3X/4X/Bio . . . . . . . . . . . . . . .387<br />
Cell Changers for LAMBDA 6XX/8XX/9XX . . . . . . . . . . . . . . . . . .388<br />
Cell Holders . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .388-389<br />
Cylindrical Cells – Macro with PTFE Stopper . . . . . . . . . . . . . . . . . . .391<br />
Flow-through Cells . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .391<br />
Lids and Stoppers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .391<br />
Replacement Tubing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .391<br />
Standard Cells for Spectroscopy . . . . . . . . . . . . . . . . . . . . . . . .392-394<br />
Macro with PTFE Lid . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .392<br />
Macro with PTFE Stopper . . . . . . . . . . . . . . . . . . . . . . . . . . . . .392<br />
Micro with PTFE Lid . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .393<br />
Micro with PTFE Stopper . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .393<br />
Semi-micro with PTFE Lid – Black . . . . . . . . . . . . . . . . . . . . . . .393<br />
Semi-micro with PTFE Lid – Clear . . . . . . . . . . . . . . . . . . . . . . .393<br />
Semi-micro with PTFE Stopper – Black . . . . . . . . . . . . . . . . . . .394<br />
Semi-micro with PTFE Stopper – Clear . . . . . . . . . . . . . . . . . . .394<br />
Ultra-micro with PTFE Lid . . . . . . . . . . . . . . . . . . . . . . . . . . . . .394<br />
Ultra-micro with Pipette Tips . . . . . . . . . . . . . . . . . . . . . . . . . . .394<br />
Consumables and Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . .395-397<br />
Calibration Reference Materials . . . . . . . . . . . . . . . . . . . . . . . .395-396<br />
Miscellaneous Calibration Materials . . . . . . . . . . . . . . . . . . . . . .396<br />
Secondary Reference Materials . . . . . . . . . . . . . . . . . . . . . . . . .395<br />
Spectralon Diffuse Color Reference Material . . . . . . . . . . . . . . . .396<br />
Spectralon ® UV/Vis/NIR Diffuse<br />
Reflectance Reference Material . . . . . . . . . . . . . . . . . . . . . . . . .396<br />
Source Lamps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .397<br />
Deuterium and Tungsten Source Lamps . . . . . . . . . . . . . . . . . . .397<br />
Deuterium and Tungsten Source Lamps . . . . . . . . . . . . . . . . . . . . .397<br />
Fiber Optics Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .380<br />
General Purpose Optical Bench Kits<br />
for the LAMBDA 6XX/8XX/9XX . . . . . . . . . . . . . . . . . . . . . . . . . . . . .380<br />
Integrating Sphere Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . .381<br />
Polarimetry Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .399-400<br />
Interference Filters, Replacement<br />
Parts and Source Lamps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .400<br />
Polarimetry Cells . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .399<br />
Polarimetry Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .400<br />
Secondary Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .400<br />
Polarizer/Depolarizer Accessories . . . . . . . . . . . . . . . . . . . . . . . . . .382<br />
Research Peltier System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .386<br />
Routine Peltier Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .385<br />
Sippers and Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . .382-383<br />
Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .398<br />
UV/Vis Application and Operating System Software . . . . . . . . . . . . . .398<br />
Advanced Applications Software . . . . . . . . . . . . . . . . . . . . . . . .398<br />
UV WinLab . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .398<br />
Specular Reflectance Accessories . . . . . . . . . . . . . . . . . . . . . . . . . .384<br />
Standard Cells for Spectroscopy . . . . . . . . . . . . . . . . . . . . . . .392-394<br />
Macro with PTFE Lid . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .392<br />
Macro with PTFE Stopper . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .392<br />
Micro with PTFE Lid . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .393<br />
Micro with PTFE Stopper . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .393<br />
Semi-micro with PTFE Lid – Black . . . . . . . . . . . . . . . . . . . . . . . . . .393<br />
Semi-micro with PTFE Lid – Clear . . . . . . . . . . . . . . . . . . . . . . . . . .393<br />
Semi-micro with PTFE Stopper – Black . . . . . . . . . . . . . . . . . . . . . .394<br />
Semi-micro with PTFE Stopper – Clear . . . . . . . . . . . . . . . . . . . . . . .394<br />
Ultra-micro with PTFE Lid . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .394<br />
Ultra-micro with Pipette Tips . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .394<br />
UV WinLab . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .398<br />
Alphabetical UV Visible Index<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
443
Terms and Conditions of Sale<br />
Terms and Conditions of Sale
Terms and Conditions of Sale<br />
1. Delivery Dates and Prices<br />
a) All delivery and shipment dates indicated on the face<br />
hereof are approximate and subject to Seller's availability<br />
schedule. Seller will make reasonable efforts to meet the<br />
delivery date(s) quoted. However, Seller will not be liable<br />
for its failure to meet the quoted delivery dates or for any<br />
delay in performance hereunder due to unforeseen<br />
circumstances or shortages, due to causes beyond its<br />
control, or due to its voluntary or mandatory compliance<br />
with any governmental act, regulation, or request. If, by<br />
reason of such circumstances, Seller's <strong>supplies</strong> of the<br />
equipment or service (hereinafter the “Product(s)”) covered<br />
hereby are limited, Seller shall have the right to allocate the<br />
available supply among its customers in such manner as it,<br />
in its sole discretion, determines appropriate.<br />
b) All orders are priced on the basis of an estimated<br />
shipment date within ninety (90) days of the date of order<br />
to the stated destination. Should Buyer request a change in<br />
the estimated shipment date or otherwise cause delay in<br />
delivery beyond ninety (90) days from the date of order or<br />
request that the Products be shipped outside the country of<br />
original delivery, the prices established by this quote shall<br />
no longer apply, and Seller's list prices in effect on the<br />
actual date of shipment shall be used in determining the<br />
price to be paid. Except as provided above, if the price is<br />
stated by reference to a published price list, then the price<br />
shall be the price on the published price list in effect at the<br />
time Seller receives Buyer's purchase order, without regard<br />
to the requested delivery date. However, if any Product is<br />
ordered prior to the effective date of a published price<br />
change and the delivery date is rescheduled, the price in<br />
effect at the time of the initial delivery date shall apply.<br />
c) If Buyer requests shipment to a country other than the<br />
country originally requested, and if Seller elects not to<br />
cancel the order pursuant to Paragraph 12 hereof, Seller's<br />
applicable surcharge for the actual country of delivery shall<br />
be added to the price.<br />
d) Notwithstanding any provision to the contrary herein, all<br />
prices are subject to increase without notice to reflect<br />
changes in: (1) Federal or State laws taxing raw material or<br />
processed materials; (2) applicable laws or regulations<br />
governing working hours or compensation of labor; and/or<br />
(3) freight charges, insurance costs, duty or other factors<br />
affecting costs of shipment.<br />
2. Packing and Loss or Damage in Transit.<br />
Products will be packed for shipment in a manner suitable<br />
to the method of shipment specified by Buyer, or to the<br />
method selected by Seller in the absence of instructions.<br />
Unless otherwise indicated on the face hereof, all sales<br />
hereunder are f.o.b. shipping point, and all risk of loss or<br />
damage to equipment in transit is upon Buyer. Payment will<br />
be made in accordance with Paragraph 5 below.<br />
3. Payment Due For Partial Deliveries.<br />
Seller may, in its sole discretion, deliver any portion of the<br />
Products ordered, regardless of utility to Buyer in the<br />
absence of the undelivered portion, and all such partial<br />
deliveries shall be accepted and paid for in accordance with<br />
the terms of Paragraphs 4 and 5 below. Likewise,<br />
completion of any installation services shall not be a<br />
condition to Buyer's obligation to remit payment. The<br />
making of a partial delivery that, to any extent, is not in<br />
accordance with the contract of sale shall not affect the<br />
Buyer's obligation hereunder to remit payment.<br />
4. Inspection, Acceptance and Return<br />
of Products or Trade-Ins.<br />
Buyer shall inspect the Products immediately upon receipt<br />
and shall, within five (5) business days after receipt, give<br />
written notice to Seller of any claim for shortage or that the<br />
Products do not conform with the terms of the contract of<br />
sale. If Buyer shall fail to give such notice, the Products<br />
shall be deemed accepted and to conform with the terms<br />
of the contract of sale, and Buyer shall be bound to pay for<br />
the Products in accordance with the terms of Paragraph 5<br />
below. Return of Products, defective or otherwise, will not<br />
be accepted by Seller without (i) written notification from<br />
Buyer to Seller within 30 days of receipt of invoice and<br />
(ii) receipt of a return authorization number from Seller.<br />
Products authorized to be returned shall be shipped f.o.b.<br />
destination, freight pre-paid. When return of nonconforming<br />
goods has been accepted by Seller, conforming shipment<br />
may be made in accordance with Paragraph 1 above and<br />
Paragraph 8 below without further liability on Seller's part.<br />
Buyer will be liable for restocking charges in the event<br />
Products are returned to the Seller which are not defective<br />
and are in accordance with these terms. When a trade-in<br />
is authorized by Seller, Buyer shall ship, f.o.b. destination,<br />
freight pre-paid, the material or equipment so authorized<br />
for trade-in, to Seller's specified location.<br />
5. Payment and Credit Terms.<br />
Unless otherwise indicated on the face hereof, Buyer agrees<br />
to remit payment in full to the address provided on the face<br />
of Seller's invoice for all shipments, including shipments of<br />
any portion of the Products ordered, upon receipt of<br />
invoice. This obligation shall not be contingent upon the<br />
completion of any installation services included in the<br />
purchase price. No cash discounts will be granted. Account<br />
balances not paid in accordance with these terms are<br />
subject to the maximum prevailing legal interest rate<br />
calculated from date of delinquency. In the event Seller<br />
finds it necessary to refer an account to an attorney or an<br />
agent for collection of delinquent accounts, Buyer shall pay<br />
all costs of collection including, without limitation,<br />
reasonable attorneys' fees. Buyer agrees that Seller shall<br />
retain a security interest in the Products sold hereunder to<br />
secure any portion of the price not paid on delivery and<br />
will, on request, execute a security agreement in such form<br />
as is required by Seller, which, at Seller's option, may be<br />
filed with appropriate local, state, or other relevant<br />
authorities. Should Buyer become delinquent in the<br />
payment of any sum due hereunder, or if Buyer becomes<br />
insolvent, or if any proceedings are commenced under any<br />
bankruptcy or similar laws for Buyer's reorganization or<br />
other debt adjustment, Seller will not be obligated to<br />
continue performance. Seller reserves the right to change<br />
the credit terms provided herein when, in Seller's opinion,<br />
the financial condition or previous payment record of Buyer<br />
so warrants. If, within thirty (30) days of receipt of written<br />
notice of such change, Buyer fails to agree and comply with<br />
different terms of credit, and/or fails to give adequate<br />
assurance of due performance, Seller may (a) by notice to<br />
Buyer, treat such failure or refusal as a repudiation by<br />
Buyer of the portion of the purchase order not then fully<br />
performed, whereupon Seller may cancel all further<br />
deliveries and any amounts unpaid hereunder shall<br />
immediately become due and payable; or (b) make<br />
shipments under reservation of a demand for advance<br />
payment or payment against tender of documents of title.<br />
Buyer's acceptance of delivery of any Products shall<br />
constitute a representation that Buyer is solvent.<br />
Terms and Conditions of Sale<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
445
Terms and Conditions of Sale<br />
Terms and Conditions of Sale<br />
6. Taxes.<br />
Buyer is responsible for the ultimate payment of all taxes<br />
which may be assessed or levied on or on account of<br />
Products sold hereunder to Buyer, whether termed a gross<br />
receipts tax, use tax, property tax, sales tax or otherwise.<br />
Where Buyer claims that a transaction is not subject to any<br />
such tax, that Buyer is exempt, or that Seller is not required<br />
to collect such tax, Buyer agrees to provide Seller with any<br />
documentation necessary to support such a claim, to allow<br />
Seller to document its decision not to collect such tax(es),<br />
and to indemnify and hold Seller harmless from and against<br />
any and all fines, penalties, interest, taxes, and other<br />
expenses, including, without limitation, reasonable<br />
attorney's fees, incurred by Seller as a result of reliance<br />
upon Buyer's position.<br />
7. Installation and Site Preparation.<br />
Installation services are included in the purchase price of<br />
the Products sold hereunder only if expressly so stated on<br />
the face of Seller's quotation or in Seller's applicable price<br />
list. Installation services for Products transferred outside the<br />
country of original delivery by Buyer's actions may be<br />
subject to additional charges based on the actual installation<br />
site location. For Products requiring installation by Seller's<br />
service personnel, it is the responsibility of Buyer to<br />
prepare the site environmentally and provide the required<br />
services, power, water, drain, air, bottled gases, permits,<br />
licenses, approvals, etc., as well as whatever is required to<br />
uncrate and transport the Product to its appropriate location<br />
for use. Failure to do so, prior to Seller's service personnel<br />
arriving at Buyer's site on the mutually agreed upon<br />
installation date, will result in a service charge by Seller to<br />
cover the lost time of its service personnel. Should Seller be<br />
unable to perform the required installation services within<br />
twelve months of a Product's shipment date as a result of<br />
Buyer's inability to prepare the site as required, Buyer may<br />
be responsible for additional costs associated with required<br />
hardware, software and firmware updates. Because Seller's<br />
service personnel may be required to enter upon Buyer's<br />
premises for the purpose of providing service to the<br />
Products sold hereunder, Buyer hereby undertakes to<br />
maintain its premises in a safe condition and to comply<br />
with all applicable laws, statutes and regulations governing<br />
workplace health and safety, and hereby accepts full<br />
responsibility for any harm or injury to, or liability arising<br />
from work performed by, Seller's personnel while on<br />
Buyer's premises, except to the extent caused solely by the<br />
gross negligence or willful misconduct of Seller's personnel.<br />
Seller's sales and service personnel are not authorized to<br />
enter into any indemnity or hold harmless agreements on<br />
behalf of Seller.<br />
8. Limited Warranty.<br />
a) Warranty.<br />
i) Seller warrants to Buyer that the Products sold to Buyer<br />
are, at the time of shipment to Buyer from Seller, free from<br />
defects in materials and workmanship.<br />
ii) This warranty shall be valid for a period of 90 days from<br />
the date of shipment to Buyer, unless a different period is<br />
specified herein, or in Seller's applicable price list in which<br />
case such specified period shall apply. Notwithstanding<br />
anything to the contrary contained herein, the warranty<br />
period for data processing equipment, including data<br />
storage devices, processors, printers, terminals,<br />
communication interfaces, tape drives and all similar<br />
devices, is in all cases limited to ninety (90) days from<br />
the date of shipment to Buyer.<br />
iii) Except in the case of an authorized distributor of Seller,<br />
authorized in writing by Seller to extend this warranty to<br />
distributor's customers, the warranty herein applies only to<br />
Buyer as the original purchaser from Seller and may not be<br />
assigned, sold or otherwise transferred to any third party.<br />
iv) As Buyer's sole and exclusive remedy under this<br />
warranty, Seller agrees either to repair or replace, at Seller's<br />
sole option, any part or parts of such Products which,<br />
under proper and normal conditions of use, prove(s) to<br />
be defective within the applicable warranty period.<br />
Alternatively, Seller may at any time, in its sole discretion,<br />
elect to discharge its warranty obligation hereunder by<br />
accepting the return of any defective Product pursuant<br />
to the terms set forth herein and refunding the purchase<br />
price paid by Buyer.<br />
b) Exclusions and Limitations.<br />
i) It is recognized that some parts by their nature may not<br />
function for the warranty period applicable to the Product.<br />
Therefore, expressly excluded from the warranty herein are<br />
chromatography columns, filaments, energy sources, lamps,<br />
power amplifier tubes, graphite tubes, sample cell holders,<br />
burner and furnace chambers, nebulizers, and other similar<br />
parts referenced in the Product's applicable operating<br />
manual.<br />
ii) The warranty herein excludes any equipment or<br />
accessories which are identified on applicable price lists,<br />
quotations, special promotional materials, or on the face<br />
hereof, for which this limited warranty may be further<br />
limited. Included within this category are items produced<br />
by third party manufacturers (as to which Seller passes<br />
to Buyer the warranty it has been provided by the<br />
manufacturer) and items which are sold at specially<br />
reduced prices with reduced warranty protection (in some<br />
cases, extended warranty protection may be available at<br />
an increased price).<br />
iii) This warranty does not cover loss, damage, or defects<br />
resulting from: transportation to the Buyer's facility,<br />
improper or inadequate maintenance by Buyer, Buyersupplied<br />
software or interfacing, unauthorized modification<br />
or misuse, operation outside of the environmental<br />
specifications for the Product or improper site preparation<br />
or maintenance.<br />
iv) No warranty is made with respect to used,<br />
reconstructed, refurbished or previously owned Products,<br />
which will be so marked on the face hereof and, unless<br />
otherwise indicated on the face hereof, shall be sold "As Is".<br />
v) The warranty herein applies only to Products within the<br />
country of original delivery. Products transferred outside<br />
the country of original delivery, either by Seller at the<br />
direction of Buyer or by Buyer's actions subsequent to<br />
delivery, may be subject to additional charges prior to<br />
warranty repair or replacement of such Products based on<br />
the actual location of such Products and Seller's warranty<br />
and/or service surcharges for such location(s).<br />
c) Place of Service.<br />
Except when otherwise provided in Seller's current<br />
applicable price list, Seller shall use reasonable efforts to<br />
perform all warranty services hereunder at Buyer's facility,<br />
as soon as reasonably practicable after notification by Buyer<br />
of a possible defect; provided, however, that Seller reserves<br />
the right to require that Buyer return the Product to Seller's<br />
production facility, transportation charges prepaid, when<br />
necessary to provide proper warranty service.<br />
446
Terms and Conditions of Sale<br />
d) Software and Firmware Products.<br />
The sole and exclusive warranty applicable to software<br />
and firmware products provided by Seller for use with a<br />
processor is as follows: Seller warrants that such software<br />
and firmware will conform to Seller's program manuals<br />
current at the time of shipment to Buyer when properly<br />
installed on the processor, provided, however, that Seller<br />
does not warrant that the operation of the processor or<br />
software or firmware will be uninterrupted or error-free.<br />
SELLER MAKES NO OTHER WARRANTIES, WHETHER<br />
EXPRESS OR IMPLIED, WITH RESPECT TO THE<br />
PRODUCTS, INCLUDING, WITHOUT LIMITATION,<br />
THE IMPLIED WARRANTIES OF MERCHANTABILITY<br />
AND FITNESS FOR A PARTICULAR PURPOSE.<br />
9. Exclusive Remedies.<br />
THE REMEDIES PROVIDED HEREIN ARE BUYER'S SOLE<br />
AND EXCLUSIVE REMEDIES. SELLER SHALL NOT BE<br />
LIABLE FOR ANY INDIRECT, SPECIAL, INCIDENTAL,<br />
CONSEQUENTIAL OR PUNITIVE DAMAGES, WHETHER<br />
BASED ON CONTRACT, TORT, STRICT LIABILITY OR<br />
OTHERWISE, ARISING OUT OF THE DESIGN,<br />
MANUFACTURE, SALE, DELIVERY, INSTALLATION,<br />
SERVICE OR USE OF THE PRODUCTS. SELLER NEITHER<br />
ASSUMES NOR AUTHORIZES ANY OTHER PERSON TO<br />
ASSUME FOR IT ANY OTHER LIABILITY IN<br />
CONNECTION WITH THE DESIGN, MANUFACTURE,<br />
SALE, DELIVERY, INSTALLATION, SERVICE OR USE OF<br />
THE PRODUCTS.<br />
10. Patent Indemnity.<br />
Seller agrees to defend, at its own expense, any suit or legal<br />
proceeding which may be brought against Buyer alleging<br />
infringement by Buyer of any patent of the United States, as<br />
a result of Buyer's use of the Product sold hereunder for its<br />
intended purposes, provided that Buyer shall give Seller<br />
prompt written notice of any claim, threat, or institution of<br />
any such suit or legal proceeding, and provided further that<br />
Seller shall then have the sole right to control and conduct<br />
the defense and/or settlement of such claim, threat, suit or<br />
legal proceeding, either in the name of Seller or Buyer or<br />
both, and Buyer shall, at Seller's request and expense,<br />
provide relevant information and reasonable cooperation.<br />
Seller shall pay all final judgments and all costs and<br />
attorney's fees assessed against Buyer in any such suit or<br />
legal proceeding, provided Buyer has complied with the<br />
conditions hereof with respect to prompt notice and<br />
cooperation in connection with such suit or legal<br />
proceeding and given exclusive control thereof to Seller.<br />
Notwithstanding the foregoing, Seller shall not be liable for<br />
any attorney's fees or other legal expenses incurred by<br />
Buyer without the knowledge and prior written consent of<br />
Seller. Seller shall have the right, at its own expense, to<br />
procure for Buyer the right to continue using the Product<br />
claimed to infringe, replace said Product with an equally<br />
satisfactory non-infringing Product, modify said Product so<br />
that it becomes non-infringing, or remove such Product and<br />
refund the purchase price thereof less a reasonable amount<br />
for use, damage or obsolescence.<br />
The foregoing indemnity fully defines Seller's obligation for<br />
patent infringement. Such obligations shall specifically not<br />
apply to:<br />
a) an infringement claim resulting from additions or<br />
changes in or to the Product made by Buyer or any third<br />
party or from use in combination with other equipment;<br />
or<br />
b) an infringement claim which is settled without the<br />
prior written consent of Seller; or<br />
c) an infringement claim which results from compliance<br />
by Seller with specifications furnished by Buyer.<br />
The total amount of Seller's obligation and liability under<br />
this Section shall not exceed the price paid by Buyer to<br />
Seller for the Product held to infringe, and in no event will<br />
Seller be held accountable for consequential damages under<br />
this indemnity, such as loss of business profits or goodwill.<br />
With respect to any infringement claim arising from Product<br />
manufactured in whole or in part to Buyer's specifications<br />
or from use of such Product in conjunction with any other<br />
goods , Buyer will indemnify and hold harmless Seller from<br />
and against all such claims for damages or profits arising<br />
from infringement of patents, designs, copyrights or<br />
trademarks.<br />
11. Modification of Terms.<br />
BUYER'S ACCEPTANCE OF ANY QUOTATION IS<br />
EXPRESSLY SUBJECT TO BUYER'S ASSENT TO EACH<br />
AND ALL OF THE TERMS AND CONDITIONS SET FORTH<br />
IN SELLER'S QUOTATION, AND BUYER'S ASSENT TO<br />
THESE TERMS AND CONDITIONS OF SALE SHALL BE<br />
CONCLUSIVELY PRESUMED FROM BUYER'S<br />
SUBMISSION OF ITS PURCHASE ORDER. NO ADDITION<br />
TO OR MODIFICATION OF SAID TERMS AND<br />
CONDITIONS SHALL BE BINDING UPON SELLER<br />
UNLESS SPECIFICALLY AGREED TO BY SELLER IN<br />
WRITING. IF BUYER'S PURCHASE ORDER OR OTHER<br />
CORRESPONDENCE CONTAINS TERMS OR CONDITIONS<br />
CONTRARY TO OR IN ADDITION TO THE TERMS AND<br />
CONDITIONS CONTAINED HEREIN OR IN SELLER'S<br />
QUOTATION, ACCEPTANCE OF ANY ORDER BY SELLER<br />
SHALL NOT BE CONSTRUED AS ASSENT TO SUCH<br />
CONTRARY OR ADDITIONAL TERMS AND CONDITIONS<br />
OR CONSTITUTE A WAIVER BY SELLER OF ANY OF THE<br />
TERMS AND CONDITIONS CONTAINED HEREIN OR IN<br />
SELLER'S QUOTATION. SELLER'S ACCEPTANCE OF<br />
BUYER'S PURCHASE ORDER IS EXPRESSLY<br />
CONDITIONED ON BUYER'S ASSENT TO THESE TERMS<br />
AND CONDITIONS. NO MODIFICATION OR WAIVER OF<br />
THESE TERMS AND CONDITIONS IS VALID, UNLESS<br />
CONFIRMED IN WRITING BY AN AUTHORIZED<br />
REPRESENTATIVE OF SELLER.<br />
12. Authority to Export.<br />
ALL ORDERS ACCEPTED FOR EXPORT (AND/OR RE-<br />
EXPORT) ARE SUBJECT TO: 1) UNITED STATES<br />
GOVERNMENT EXPORT REGULATIONS; AND 2) BUYER<br />
PROVIDING SELLER WITH ALL DOCUMENTATION<br />
NECESSARY FOR SHIPMENT TO THE DESTINATION<br />
COUNTRY.<br />
13. Software Licenses and Copyrighted Material.<br />
a) Seller provides software products by license only. The<br />
terms of the license are available from Seller and are<br />
deemed accepted by Buyer on delivery of licensed software.<br />
b) Unless otherwise specified, Seller's copyrighted material<br />
(software, firmware, and printed documentation) may not<br />
be copied except for archive purposes, to replace a defective<br />
copy, or for program error verification by Buyer.<br />
Terms and Conditions of Sale<br />
See page 42 for ordering information.<br />
For the most current product listing,<br />
visit www.perkinelmer.com/<strong>supplies</strong><br />
447
Terms and Conditions of Sale<br />
Terms and Conditions of Sale<br />
14. Miscellaneous.<br />
a) Excusable Delays.<br />
Seller shall not be liable for delays in delivery or failure to<br />
manufacture or deliver goods due to acts of God, acts or<br />
failures to act of Buyer, acts of civil military authority, fires,<br />
strikes, floods, epidemics, attack, war, delays in<br />
transportation or other causes beyond Seller's reasonable<br />
control, including, without limitation, delays in obtaining<br />
or inability to obtain necessary labor, materials,<br />
components, or manufacturing facilities.<br />
b) Governing Law.<br />
The contract of sale shall be governed by and construed in<br />
accordance with the laws of the Commonwealth of<br />
Massachusetts, U.S.A. without regard to its principles of<br />
conflict of laws. Any disputes relating to the contract of sale<br />
between Buyer and Seller shall be adjudicated in the state<br />
or federal courts in the Commonwealth of Massachusetts,<br />
U.S.A., and both parties hereby consent to the exclusive<br />
jurisdiction of said courts for purposes of any such<br />
litigation. The parties expressly agree to waive application<br />
of the United Nations Convention on Contracts for the<br />
International Sale of Goods.<br />
c) Confidential Data and Information.<br />
If, in connection with the sale, purchase, use, or<br />
maintenance of the Products, Seller is requested, required,<br />
or deems it advisable to furnish data or information which<br />
it, in its sole discretion, deems proprietary, confidential, or<br />
both, Seller shall not, in any event, submit or be required to<br />
furnish such data or information unless Buyer enters into<br />
an agreement concerning the handling, use, copying,<br />
retention and return of such information, the form of which<br />
agreement is available to Buyer on request. Seller does not<br />
agree to accept any proprietary or confidential information<br />
of Buyer in the absence of such a written agreement signed<br />
by an authorized representative of Seller.<br />
d) Assignment.<br />
Buyer may not assign, transfer or delegate any of its rights<br />
or obligations herein without the prior written consent of<br />
Seller, and any purported assignment of such rights or<br />
obligations without such consent shall be null and void.<br />
e) Severability.<br />
If any provision herein is deemed unenforceable by a court<br />
of competent jurisdiction, the other provisions shall remain<br />
in full force and effect as if the unenforceable provision had<br />
not been included.<br />
448
PerkinElmer and OneSource are registered trademarks of PerkinElmer, Inc. © 2005 PerkinElmer, Inc. 400073A_01<br />
Scientists aren’t the only ones making<br />
breakthrough discoveries.<br />
Procurement and sourcing pros are discovering OneSource ® – PerkinElmer’s<br />
comprehensive solution for maintaining all your lab equipment. Now they have<br />
smart ways to reduce costs and improve service quality. Scientist productivity<br />
rises too, thanks to faster maintenance response and repair times. And, best of all,<br />
the longer they work with OneSource, the greater the savings.<br />
Introducing<br />
To make your own discoveries, call today for your free maintenance audit.<br />
In the U.S. and Canada, call 303-884-9510; in Europe, call +44 (0) 7785 921164.<br />
Or send an e-mail to onesource@perkinelmer.com. See? You’re saving already.<br />
www.perkinelmer.com/onesource
www.perkinelmer.com/<strong>supplies</strong><br />
PerkinElmer Life and<br />
Analytical Sciences<br />
710 Bridgeport Avenue<br />
Shelton, CT 06484-4794 USA<br />
Phone: (800) 762-4000 or<br />
(+1) 203-925-4602<br />
www.perkinelmer.com<br />
For a complete listing of our global offices, visit www.perkinelmer.com/lasoffices<br />
©2005 PerkinElmer, Inc. All rights reserved. PerkinElmer is a trademark of PerkinElmer, Inc.<br />
007386_03 Printed in the USA