28.06.2015 Views

Essential supplies - AMCO Instruments, SRL

Essential supplies - AMCO Instruments, SRL

Essential supplies - AMCO Instruments, SRL

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

www.perkinelmer.com/<strong>supplies</strong><br />

Consumables and Accessories<br />

2006-2007 Catalog<br />

<strong>Essential</strong> <strong>supplies</strong><br />

for your analytical instruments<br />

Atomic Absorption<br />

Elemental Analysis<br />

Gas Chromatography<br />

Inductively Coupled Plasma – MS<br />

Inductively Coupled Plasma – OES<br />

Infrared Spectroscopy<br />

Liquid Chromatography<br />

Thermal Analysis<br />

UV Visible


Proven Quality, Reliability and Results<br />

Why Order from PerkinElmer?<br />

PerkinElmer Consumables and Accessories Reliability and Results<br />

In today’s demanding and often fast-paced laboratory<br />

environments, both scientists and administrators face<br />

a variety of challenges. Expanding workloads, limited<br />

resources, condensed timelines and increasingly<br />

complex regulations must be managed – without<br />

impact on accuracy and quality. Every element of<br />

your laboratory must be in sync… right down to the<br />

consumables for your instruments. This means that<br />

your suppliers must have systems in place that make your<br />

job easier by saving you time and money.<br />

Reliable performance<br />

At PerkinElmer, we’ve been serving a number of<br />

dynamic and diverse industries for over fifty years,<br />

and have a deep understanding of a laboratory’s<br />

requirements. With our precision-designed products,<br />

simple ordering process and best-in-class customer<br />

service, you can enjoy the peace of mind that comes<br />

with solid, reliable support. You’ll get the results you<br />

need – accurately and on time – with confidence.<br />

Plus, PerkinElmer consumables and accessories are<br />

guaranteed for PerkinElmer instruments, and many<br />

can be used with other manufacturers’ instruments.<br />

Superior quality and support<br />

We at PerkinElmer understand the ever-changing<br />

and evolving needs of your laboratory and business,<br />

and we continuously work to develop greater<br />

technological innovations to support your needs.<br />

Our instruments are backed by superior-quality<br />

service and support to provide you with peace of<br />

mind that your laboratory will operate smoothly.<br />

From routine sample testing to those “eureka”<br />

moments of unimaginable scientific breakthroughs,<br />

you can count on PerkinElmer to help you achieve<br />

your goals.<br />

How To Use This Catalog<br />

Product categories in the catalog are color-coded for quick<br />

reference (see below). Please use the Table of Contents on the<br />

next page to locate the product category you are looking for.<br />

Atomic Absorption<br />

Elemental Analysis<br />

Gas Chromatography<br />

Inductively Coupled Plasma – MS<br />

Inductively Coupled Plasma – OES<br />

Infrared Spectroscopy<br />

Liquid Chromatography<br />

Thermal Analysis<br />

UV Visible<br />

www.perkinelmer.com/<strong>supplies</strong><br />

See pages 2-4 for ordering information.<br />

On the edge of each page are color-coded VERTICAL<br />

bars that provide you with a quick reference for locating<br />

product categories AND the specific products you can find<br />

on that page. In addition, products are alphabetized by<br />

category, subcategory and family.<br />

For your reference there are two INDEX options:<br />

1. Alphabetical INDEX – See page 429<br />

2. Part Number INDEX – See page 406<br />

For advanced shopping features (such as accessing<br />

product availability dates or scheduling standing orders),<br />

refer to the ADVANCED Guide to Online Ordering in the back<br />

of this catalog on page 401.<br />

At PerkinElmer, we’ve made ordering easy. You can place<br />

your order by phone, fax, e-mail or mail. Simply contact<br />

your local office directly (see pages 2-4 for local office<br />

listings), and be sure to ask if online ordering is available<br />

in your area.


Table of Contents<br />

Product Category<br />

Page<br />

Atomic Absorption 5-72<br />

Elemental Analysis 73-84<br />

Gas Chromatography 85-184<br />

Inductively Coupled Plasma – MS 185-212<br />

Inductively Coupled Plasma – OES 213-236<br />

Infrared Spectroscopy 237-266<br />

Liquid Chromatography 267-332<br />

Thermal Analysis 333-376<br />

UV Visible 377-400<br />

ADVANCED Guide to Online Ordering 401-405<br />

INDEX: Alphabetical INDEX 429-443<br />

Part Number INDEX 406-428<br />

Terms and Conditions 444-448<br />

Table of Contents PerkinElmer Consumables and Accessories


Global Expertise... Local Support<br />

Personalized Service from a PerkinElmer Office Near You<br />

PerkinElmer Consumables and Accessories Local Support<br />

AFRICA<br />

ALGERIA • BENIN • BURKINA<br />

BURUNDI • CAMEROON<br />

CAPE VERDE<br />

CENTRAL AFRICAN REPUBLIC<br />

CHAD • COMOROS • CONGO<br />

DEMOCRATIC REPUBLIC OF CONGO<br />

DSCHIBUTI REPUBLIC<br />

EQUATORIAL GUINEA<br />

GABON • GAMBIA • GUINEA<br />

GUINEA – BISSAU • IVORY COAST<br />

MADAGASCAR • MALI • MAURITANIA<br />

MOROCCO • NIGER • REUNION<br />

RWANDA • SENEGAL • SEYCHELLES<br />

TOGO • TUNISIA • WESTERN SAHARA<br />

HTDS<br />

Tel: 33 1 64 86 28 28<br />

Fax: 33 1 69 07 69 54<br />

Email: philippe.lelievre@htds.fr<br />

ANGOLA • BOTSWANA • LESOTHO<br />

MALAWI • MAURITIUS<br />

MOZAMBIQUE • NAMIBIA<br />

SOUTH AFRICA • SWAZILAND<br />

ZAMBIA • ZIMBABWE<br />

Life and Analytical Sciences (PTY) Ltd.<br />

Tel: 27 (0)11 794 4430<br />

Fax: 27 (0)11 794 2160<br />

Email: sales@perkinelmersa.co.za<br />

BRITISH INDIAN OCEAN<br />

ERITREA • ETHIOPIA • GHANA<br />

KENYA • LIBERIA • NIGERIA<br />

SIERRE LEONE • SOMALIA<br />

SUDAN • TANZANIA<br />

UGANDA • WESTERN SAHARA<br />

HTDS-International<br />

Tel: 202 290 5306<br />

Fax: 202 290 5307<br />

Email: Nagui.Sadek@htds.fr<br />

IA<br />

ASIA<br />

BANGLADESH<br />

Overseas Marketing Corporation<br />

(Pvt.) Ltd<br />

Tel: 880-2-8154510<br />

Fax: 880-2-8156739<br />

Email: analytical@omcbd.com<br />

CHINA<br />

Beijing<br />

Tel: 86-10-6566 8166<br />

Fax: 86-10-6566 8155<br />

Chengdu<br />

Tel: 86-28-8678 2887<br />

86-28-8678 2662<br />

Fax: 86-28-8678 2522<br />

Guangzhou<br />

Tel: 86-20-8363 3176<br />

86-20-8363 3177<br />

86-20-8363 3179<br />

Fax: 86-20-8363 3579<br />

Shanghai<br />

Tel: 86-21-6391 2388<br />

Fax: 86-21-6391 2822<br />

Shenyang<br />

Tel: 86-24-2256 6158<br />

Fax: 86-24-2256 6153<br />

Wuhan<br />

Tel: 86-27-8732 2732<br />

86-27-8732 2826<br />

86-27-8712 8756<br />

Fax: 86-27-8732 2685<br />

HONG KONG<br />

Tel: 852-2620-1881<br />

Fax: 852-2620-1238<br />

INDIA<br />

PerkinElmer India (Pvt.) Ltd.<br />

Tel: 91 22 2570 1101<br />

91 22 2570 1102<br />

91 22 2570 1103<br />

Fax: 91 22 2570 1105<br />

Email: ramani.gopi@perkinelmer.com<br />

INDONESIA<br />

Tel: 62-21-55960248<br />

Fax: 62-21-55960247<br />

JAPAN<br />

Tel: 81-45-314-8381<br />

Fax: 81-45-314-5142<br />

KOREA<br />

Tel: 82-2-592-2998<br />

Fax: 82-2-3478-7979<br />

MALAYSIA<br />

Tel: 60-3-7958-1118<br />

Fax: 60-3-7958-5688<br />

NEPAL<br />

Associated Enterprises<br />

Tel: 977 1 4250934<br />

Fax: 977 1 4261744<br />

Email: info@asoent.com<br />

PAKISTAN<br />

Analytical Measuring Systems<br />

(Pvt.) Limited<br />

Tel: 92-21-5345581<br />

Fax: 92-21-5345582<br />

Email: amsana@cyber.net.pk<br />

Zahid.Mustafa@amspvtltd.com<br />

PHILIPPINES<br />

Tel: 63-2-6370180<br />

Fax: 63-2-9101168<br />

SINGAPORE<br />

Tel: 65-67799555<br />

Fax: 65-68726595<br />

SRI LANKA<br />

Colombo Traders<br />

Tel: 94 11 269 6121<br />

Fax: 94 11 269 8832<br />

Email: gpedris@sltnet.lk<br />

TAIWAN<br />

Kaohsiung<br />

Tel: 886-7-552-1030<br />

Fax: 886-7-554-3402<br />

Taipei<br />

Tel: 886-2-2764-7199<br />

Fax: 886-2-2764-7209<br />

THAILAND<br />

Tel: 662-3197901<br />

Fax: 662-3197900<br />

VIETNAM<br />

Saigon Instrumentation Joint<br />

Stock Company<br />

Tel: 844-747-2258<br />

Fax: 844-747-2260<br />

EUROPE<br />

ALBANIA • MACEDONIA<br />

Interlab d.o.o<br />

Tel: 389 2 3298 810<br />

Fax: 389 2 3118 279<br />

Email: interlab@mt.net.mk<br />

ARMENIA • AZERBAIJAN • BELARUS<br />

GEORGIA • KAZAKHSTAN<br />

KYRGYZSTAN • MOLDAVIA<br />

MONGOLIA • RUSSIA • TAJIKISTAN<br />

TURKMENISTAN • UKRAINE<br />

UZBEKISTAN<br />

Scheltec AG<br />

Tel: 7 095 935 8888<br />

Fax: 7 095 564 8787<br />

Email: info@scheltec.ru<br />

BOSNIA-HERZEGOVINA<br />

Analitika d.o.o<br />

Tel: 387 33 712 062<br />

Fax: 387 33 712 061<br />

Email: analitika_sa@bih.net.ba<br />

BULGARIA<br />

Chroma Ltd<br />

Tel: 359 2 952 0301<br />

Fax: 359 2 952 3784<br />

Email: chroma@spnet.net<br />

CROATIA<br />

Hebe d.o.o<br />

Tel: 385 1 2001 767<br />

Fax: 385 1 2001 724<br />

Email: zoran.tomaskovic@hebe.hr<br />

CYPRUS<br />

C & V Kriticos Suppliers Ltd<br />

Tel: 357 (22) 33 82 34<br />

Fax: 357 (22) 33 82 32<br />

Email: vasso@kriticos.com.cy<br />

CZECH REPUBLIC<br />

PE Systems s.r.o<br />

Tel: 420 241 430 534<br />

Fax: 420 241 430 535<br />

Email: pavel.choc@pesystems.cz<br />

DENMARK<br />

Tel: 808 8 42 36<br />

Fax: 808 8 42 37<br />

Email: cc.denmark@perkinelmer.com<br />

ESTONIA<br />

Peai-Est OU<br />

Tel: 372 7 383 330<br />

Fax: 372 7 383 360<br />

Email: lploom@hot.ee<br />

2 www.perkinelmer.com/<strong>supplies</strong>


Global Expertise... Local Support<br />

Personalized Service from a PerkinElmer Office Near You<br />

GREECE<br />

Antisel (A. Selidis Bros. S. A.)<br />

Tel: 30 210 779 5980<br />

Fax: 30 210 771 6932<br />

Email: aaidini@antisel.gr<br />

HUNGARY<br />

Per-Form Hungaria KFT<br />

Tel: 361 251 1116-2163-0230<br />

Fax: 361 251 1461<br />

Email: liptak.miklos@per-form.hu<br />

ICELAND<br />

Groco ehf<br />

Tel: 354 568 8533<br />

Fax: 354 568 0304<br />

Email: eirikur@groco.is<br />

LATVIA<br />

Adrona Sia<br />

Tel: 371 755 1894<br />

Fax: 371 755 1976<br />

Email: agris@adrona.lv<br />

LITHUANIA<br />

Linea Libera<br />

Tel: 370 5 2729 054<br />

Fax: 370 5 2729 067<br />

Email: paulius.jurgutis@mega.mii.lt<br />

MALTA<br />

Technoline Ltd<br />

Tel: 00356 21 344 345<br />

Fax: 00356 21 343 952<br />

Email: sdebono@technoline-mt.com<br />

NORWAY<br />

Tel: 800 18 854<br />

Fax: 800 18 855<br />

Email: cc.norway@perkinelmer.com<br />

POLAND<br />

PerkinElmer Polska Sp. z o.o.<br />

Tel: 48 22 607 05 60<br />

Fax: 48 22 607 05 70<br />

Email: andrzej.lechotycki@<br />

perkinelmer.com<br />

PORTUGAL<br />

ILC Instrumentos de<br />

Laboratório e Científicos Lda<br />

Tel: 351 21 782 60 30<br />

Fax: 351 21 782 60 39<br />

Email: ilc@ilc.pt<br />

REPUBLIC OF IRELAND AND<br />

NORTHERN IRELAND<br />

Foss Ireland<br />

Tel: 353 1 250 1100<br />

Fax: 353 1 250 1199<br />

Email: aoreilly@foss.ie<br />

ROMANIA<br />

SC Cromatec Plus Srl<br />

Tel: 40 21 316 2876<br />

40 21 316 2877<br />

40 21 316 2878<br />

Fax: 40 21 316 2876<br />

40 21 316 2877<br />

40 21 316 2878<br />

Email: office@cromatec.ro<br />

SLOVAKIA<br />

Medic Labor S.r.o<br />

Tel: 421 48 4155008<br />

Fax: 421 48 4155007<br />

Email: slaszlo@medic-labor.sk<br />

SLOVENIA<br />

Omega d.o.o<br />

Tel: 386 1 427 3213<br />

Fax: 386 1 427 3191<br />

Email: omega@omega.si<br />

SWEDEN<br />

Tel: 0200 - 88 75 20<br />

Fax: 0200 - 88 75 21<br />

Email: cc.sweden@perkinelmer.com<br />

SWITZERLAND<br />

Tel: 0800000015<br />

Fax: 0800000016<br />

Email: cc.switzerland@<br />

perkinelmer.com<br />

TURKEY<br />

Tetra Teknolojik Sistemler Ltd<br />

Tel: 90 212 212 5566<br />

Fax: 90 212 212 2829<br />

Email: istanbul@tetratek.com.tr<br />

UNITED KINGDOM<br />

Tel: 0800-89 60 46<br />

Fax: 0800-89 17 14<br />

Email: cc.uk@perkinelmer.com<br />

YUGOSLAVIA<br />

Interlab d.o.o<br />

Tel: 381 11 2404 385<br />

Fax: 381 11 2404 385<br />

Email: interlab@eunet.yu<br />

MIDDLE EAST<br />

BAHRAIN<br />

Yousuf Mahmood Husain<br />

Tel: 973 17 276176<br />

Fax: 973 17 275819<br />

Email: reji@ymh.com.bh<br />

GAZA STRIP • IRAQ<br />

JORDAN • LEBANON • LIBYA<br />

NEUTRAL ZONE (IQ/SA)<br />

SYRIA • WEST BANK<br />

PerkinElmer Egypt Limited<br />

Tel: 20 2 391 7261<br />

Fax: 20 2 392 1162<br />

Email: sadekna@ie-eg.com<br />

EGYPT<br />

Optima Scientific Egypt HTDS<br />

Tel: 202 418 8606<br />

Fax: 202 290 5307<br />

Email: sadekna@ie-eg.com<br />

ISRAEL<br />

Saifan Precision <strong>Instruments</strong> Ltd<br />

Tel: 972-3-7565000<br />

Fax: 972-3-7565007<br />

Email: john@saifan.co.il<br />

KUWAIT<br />

Bader Sultan & Bros Co. W.L.L.<br />

Tel: 965 43325555 (Ext. 326)<br />

Fax: 965 4334217<br />

Email: hisham@sultan.com.kw<br />

OMAN<br />

Business International Group L.L.C.<br />

Tel: 968 248 14752<br />

Fax: 968 248 13924<br />

Email: bigllc@omantel.net.om<br />

PALESTINE<br />

Techno-Line<br />

Tel: 972-2-6560077<br />

Fax: 972-2-6568796<br />

Email: a.imam@techno-line.com<br />

QATAR • UNITED ARAB EMIRATES<br />

Emphor FZCO<br />

Tel: 971 4 883 0233<br />

Fax: 971 4 883 0133<br />

Email: nilesh@emphor.biz<br />

SAUDI ARABIA<br />

Abdulrehman AlgoSaibi G.T.B.<br />

Tel: 966 672 0888<br />

Fax: 966 672 5664<br />

Email: ielhajj@algosaibi-gtb.com<br />

YEMEN<br />

Alfalah Trading<br />

Tel: 967 234 5073<br />

Fax: 967 234 0504<br />

Email: direct@alfalahye.net<br />

NORTH AMERICA<br />

CANADA<br />

Montreal, Quebec<br />

Tel: 514-937-9949<br />

800-293-4501 (Canada Only)<br />

Fax: 514-937-0777<br />

Email: orders.lscanada@<br />

perkinelmer.com<br />

Woodbridge, Ontario<br />

Tel: 905-851-4585<br />

800-561-4646<br />

Fax: 905-851-1814<br />

Email: orders.lscanada@<br />

perkinelmer.com<br />

COSTA RICA<br />

Analytical <strong>Instruments</strong>, S.A<br />

Tel: 506-272-47-00<br />

Fax: 506-272-97-00<br />

Email: vargasjf@ai.co.cr<br />

DOMINICAN REPUBLIC<br />

Inversiones Tecnicas<br />

Dominicanas S.A.<br />

Tel: 809-688-4927<br />

Fax: 809-682-9506<br />

EL SALVADOR<br />

Comercio Y Representaciones, S.A.<br />

Tel: (503) 2249-7777<br />

(503)-2249-7774<br />

Fax: (503) 2249-7788<br />

Email: coresa@salnet.net<br />

GUATEMALA<br />

Anaqui Analítica Química, S.A.<br />

Tel: 502-2433-6030<br />

502-2435-5360<br />

Fax: 502-435-4464<br />

Email: arturo-avila@salnet.net<br />

HONDURAS<br />

Representaciones Handal’s<br />

Tel: 504-220-4700<br />

Fax: 504-220-5426<br />

Email: rhandals@rhandals.hn<br />

MEXICO<br />

Tel: (52) 55-53-37-07-00<br />

(52) 55-56-51-70-77<br />

Fax: (52) 55-55-93-62-23<br />

Email:<br />

daniel.zavalza@perkinelmer.com<br />

NICARAGUA<br />

Sinter S.A.<br />

Tel: 505-278-0177<br />

Fax: 505-278-0252<br />

Email: amonge@sinter.com.ni<br />

Local Support PerkinElmer Consumables and Accessories<br />

For a complete listing of all local offices and mailing addresses,<br />

go to www.perkinelmer.com/lasoffices<br />

3


Global Expertise... Local Support<br />

Personalized Service from a PerkinElmer Office Near You<br />

PerkinElmer Consumables and Accessories Local Support<br />

NORTH AMERICA (cont)<br />

PANAMA<br />

Nes Scientific, S.A.<br />

Tel: 507-221-1426<br />

507-221-1455<br />

Fax: 507-221-96-27<br />

Email: nesscien@cwpanama.net<br />

PUERTO RICO<br />

Tel: 787-783-3067<br />

Fax: 787-793-7198<br />

OCEANIA<br />

AUSTRALIA<br />

Tel: 1-800 033 391<br />

Fax: 61-3-9212-8595<br />

NEW ZEALAND<br />

New Zealand Scientific Ltd<br />

Tel: 0800 776 767<br />

Fax: 0800 776 000<br />

SOUTH AMERICA<br />

ARGENTINA<br />

Tel: 5411-4554-4004<br />

Fax: 5411-4554-2807<br />

Email: alejandro.auffenfeld@<br />

perkinelmer.com.ar<br />

BOLIVIA<br />

Beco Internacional, LTDA.<br />

Tel: (59) 12-241-5446<br />

Fax: (59) 12-241-0639<br />

Email: beco@caoba.entelnet.bo<br />

BRAZIL<br />

Tel: 55-11-3868-6200<br />

Fax: 55-11-3872-0548<br />

Email: denise.schwartz@<br />

perkinelmer.com<br />

CHILE<br />

Tel: 56-2-655-1600<br />

Fax: 56-2-269-8070<br />

Email: hector.moncada@<br />

perkinelmer.com<br />

COLOMBIA<br />

Polco, S.A.<br />

Tel: (574) 230-57-67<br />

Fax: (574) 230-56-04<br />

Email: polco@epm.net.co<br />

ECUADOR<br />

Proinstra, S.A.<br />

Tel: (593)-22-263-937<br />

(593)-22-444-363<br />

Fax: (593) 22-922-267<br />

Email: proinstra@ecutel.net<br />

PARAGUAY<br />

Tel: 5411-4554-4004<br />

Fax: 5411-4554-2807<br />

Email: alejandro.auffenfeld@<br />

perkinelmer.com.ar<br />

PERU<br />

Científica Andina S.A.<br />

Tel: (5114) 444-9993<br />

(5114) 444-9983<br />

Fax: (5114) 444-9937<br />

Email: caballca@<br />

científica-andina.com.pe<br />

URUGUAY<br />

Coasin <strong>Instruments</strong><br />

Tel: 598-2-708-5866<br />

Fax: 598-2-709-0988<br />

Email: sirexur@adinet.com.uy<br />

VENEZUELA<br />

Corporación Científica<br />

Venezolana CA<br />

Tel: 58-212-7615-221<br />

58-212-7616-239<br />

Fax: 58-212-762-3050<br />

Email: ccvivanj@telcel.net.ve<br />

Order by Phone, Fax or E-mail<br />

Please contact your local PerkinElmer Customer Care<br />

Representative. See local office listings to the left and on<br />

the prior two pages.<br />

Order by Mail<br />

Visit us online at www.perkinelmer.com/lasoffices to obtain<br />

the correct address for mailing your company Purchase Order.<br />

You can also call or e-mail your local PerkinElmer Customer<br />

Care Representative. See local phone number and e-mail<br />

listings to the left and on the prior two pages.<br />

Order Online<br />

Place your order online at: www.perkinelmer.com/<strong>supplies</strong><br />

As of catalog press time, online ordering is available in the<br />

United States, Canada and the United Kingdom. Call your local<br />

office to find out if or when online ordering will be available<br />

in your local language or region. See local office listings to the<br />

left and on the prior two pages.<br />

Technical Support<br />

For technical assistance, please contact your local PerkinElmer<br />

Customer Care Representative. See local office listings to the<br />

left and on the prior two pages.<br />

Check with your local PerkinElmer Customer Care center for current pricing.<br />

PerkinElmer is a registered trademark of PerkinElmer, Inc. All other product and company names mentioned herein may be the trademarks or registered trademarks<br />

of their respective owners.<br />

PerkinElmer is not responsible for typographical or photographic errors that may appear in this catalog. We reserve the right to make adjustments or corrections due<br />

to changing market conditions, product discontinuations, or typographical or photographic errors in advertisements or product descriptions. Policies and item<br />

availability are subject to change without notice.<br />

For details on our terms and conditions, including warranties, please see pages 444-448 or visit our website at: www.perkinelmer.com/terms<br />

4<br />

www.perkinelmer.com/<strong>supplies</strong>


PerkinElmer, the undisputed leader in Atomic<br />

Absorption (AA), is the preferred choice for atomic<br />

spectroscopy solutions and services in thousands<br />

of laboratories globally, helping you advance<br />

research and development, control product<br />

quality and improve the environment.<br />

With a product line that features flame AA,<br />

high-performance graphite furnace, standardsetting<br />

WinLab32 software and a wide array<br />

of consumables and accessories, PerkinElmer<br />

AA’s are designed to meet your most demanding<br />

requirements for productivity, flexibility,<br />

ruggedness and performance.<br />

Atomic Absorption


Atomic Absorption<br />

QUICK-FIND INDEX Page #<br />

Autosampler Sample Cups 11<br />

Autosampler Sample Probes 9<br />

Burner Heads and Components 13<br />

Electrodeless Discharge Lamps 46<br />

Filters, Regulators, and<br />

Supplies 36<br />

Flow Injection Sampling<br />

Supplies 21<br />

HGA Graphite Tubes and<br />

Contact Cylinders 31<br />

Lumina Hollow Cathode Lamps 39<br />

Matrix Modifiers 67<br />

MHS System and Supplies 49<br />

Sample Preparation Supplies 50<br />

Nebulizers 16<br />

Standards 65<br />

THGA Graphite Tubes and<br />

Contact Cylinders 34<br />

WinLab32 Software for AA 70<br />

PerkinElmer offers a wide selection of superior quality products designed to work with<br />

your PerkinElmer instruments. Our precision-designed products deliver the peace of<br />

mind that comes from knowing that you’ll get the results you need.<br />

The Quick Find Index to the left will help you find products fast. For your convenience,<br />

products are alphabetized by category, sub-category, and family. There is also a more<br />

complete Alphabetical INDEX on page 429 and a Part Number INDEX on page 407.<br />

HGA Graphite Tubes and Supplies<br />

Lumina Hollow Cathode Lamps<br />

Standards<br />

PerkinElmer tubes are manufactured to the highest quality<br />

specifications. To ensure high quality and consistency, a<br />

specific grade of high-density base graphite material has<br />

been developed for PerkinElmer’s exclusive use. This base<br />

graphite material is used for the manufacturing of all<br />

PerkinElmer graphite tubes.<br />

Page 31<br />

Every genuine PerkinElmer Lumina lamp is designed<br />

for use with, and tested on, our spectrometers to<br />

assure compatibility and the highest performance.<br />

PerkinElmer offers a wide range of single-element and<br />

multi-element HCLs, which are ideal for determining most<br />

elements by atomic absorption spectroscopy.<br />

Page 39<br />

PerkinElmer offers a wide selection of atomic absorption<br />

calibration standards. Each solution is supplied with a<br />

comprehensive Certificate of Analysis that documents<br />

the quality. To ensure that your measurements are<br />

accurate, you can rely on our certificates to provide<br />

complete information.<br />

Page 65<br />

THGA Graphite Tubes and Supplies<br />

Our exclusive design ensures even heating over the entire<br />

length of the tube. PerkinElmer’s unique, transversely<br />

heated graphite tube includes an integrated platform. The<br />

exceptionally uniform temperature distribution obtained<br />

with transverse heating significantly reduces or eliminates<br />

condensation of the sample matrix components and<br />

“memory” effects, and improves the atomization<br />

efficiency for refractory elements.<br />

Page 34


The World Leader in<br />

Atomic Absorption<br />

OVER 40 YEARS OF EXPERTISE<br />

With over 40 years experience and a product line that<br />

includes flame AA systems, high-performance graphite<br />

furnace AA systems, flexible ICP-OES systems, and the<br />

most powerful ICP-MS systems, PerkinElmer is the<br />

undisputed leader in inorganic analysis. We have<br />

placed over 40,000 systems throughout the world,<br />

performing inorganic analyses every hour of every day.<br />

AAnalyst 200<br />

PerkinElmer is a world leader in chemical analysis. Our<br />

analytical instrument technologies serve the rapidly<br />

evolving pharmaceutical, chemical, environmental,<br />

forensics, and semiconductor industries, providing<br />

integrated solutions – from sample handling and<br />

analysis – to communication of test results.<br />

AAnalyst 200<br />

The AAnalyst 200 dramatically changes<br />

the way instruments are used and serviced,<br />

while maintaining all of the performance<br />

users have come to expect from PerkinElmer.<br />

The system incorporates innovations<br />

typically only offered on expensive researchgrade<br />

instrumentation. True double-beam<br />

Echelle optics combined with the power of<br />

a solid state detector delivers performance<br />

levels not typically available with flame<br />

AA. Plus, fully automated gas controls<br />

and integrated safety checks yield the<br />

safest flame AA system available today.<br />

Features:<br />

■ Intuitive touch screen is easy-to-use —<br />

no training required<br />

■ Snap-in, snap-out parts are easily<br />

replaced, so there is no downtime<br />

■ Rugged design can handle the toughest matrices<br />

■ PerkinElmer reliability and performance<br />

at an affordable price<br />

■ Features the first true double-beam<br />

Echelle optical system<br />

AAnalyst 400<br />

The AAnalyst 400 system is designed for<br />

the rigorous needs of today’s analytical<br />

laboratory, with proven WinLab32<br />

software providing all the flexibility<br />

and power you need in an easy-to-use,<br />

easy-to-learn package.<br />

AAnalyst 600<br />

The AAnalyst 600, a dedicated<br />

transversely heated graphite atomizer<br />

(THGA) system, offers the best in<br />

graphite furnace. With Zeeman<br />

background correction, the AAnalyst<br />

600 exceeds the requirements of today’s<br />

laboratories, whether analyzing difficult<br />

samples or for achieving the lowest<br />

detection levels. The high-lightthroughput<br />

optical system combined<br />

with a solid-state detector, provides<br />

the highest quality efficiency and<br />

signal-to-noise performance of any<br />

AA system on the market.<br />

AAnalyst 700<br />

The AAnalyst 700 Atomic Absorption<br />

Spectrometer offers productivity<br />

enhancing features for flame and furnace<br />

atomic absorption in a proven costeffective<br />

design. The fully integrated<br />

benchtop system includes flame and<br />

heated graphite furnace atomizers<br />

(HGA) with continuum source<br />

background correction.<br />

AAnalyst 800<br />

For laboratories that need the best in both<br />

flame and THGA furnace, the AAnalyst<br />

800 provides a fully integrated benchtop<br />

system with superior performance. With<br />

the AAnalyst 800, switching between<br />

flame and furnace is as simple as a click<br />

of the mouse and includes automatic<br />

alignment for optimum performance.<br />

The high-light-throughput optical system<br />

combined with a solid-state detector,<br />

provides the highest quality efficiency<br />

and signal-to-noise performance of any<br />

AA system on the market.<br />

7


Atomic Absorption Autosampler Supplies and Accessories<br />

Autosampler Supplies and Accessories<br />

Autosampler Flame/FIAS Trays and Vessels<br />

Accessories<br />

Description Part No. Each (€)<br />

AS-91 Plexiglass Cover B3000111 1103<br />

AS-93plus Dust Cover B3140770 1001<br />

Plexiglass cover for reduced contamination<br />

of samples from ambient particulates<br />

Adapter Plate for Gilson Racks for AS-93plus B3140647 48<br />

Required in order to use Gilson racks on an AS-93<br />

Rinsing Kits<br />

AS-93plus Rinsing Kit<br />

Includes: Part No. Each (€)<br />

Adapter M B0507919 15<br />

Connector B3140715 2<br />

Pump Tube - 1.14 mm i.d., (pkg. 6) B3140730 57<br />

Pump Tube - 2.79 mm i.d., (pkg. 6) B3140721 60<br />

PVC Rinse Liquid Feed Tube - 2 m B0048139 1<br />

Tygon ® Drain Tube - 2 m B0509650 16<br />

Rinsing Port B3140622 36<br />

AS-90plus Rinsing Kit<br />

Includes the rinse vessel (B300-0156) and the appropriate<br />

adapter and tubing. The vessel may not<br />

fit trays manufactured prior to 1996. Part No. Each (€)<br />

Sample Trays<br />

AS-90/90A/90plus<br />

Capacity Sample Vessel Size Part No. Each (€)<br />

Tray A-144 4.5 mL, 6 mL, 8 mL B3000133 338<br />

Tray B-98* 15 mL, 16 mL B3000132 113<br />

Tray C-36 50 mL B3000135 338<br />

Blank Tray B0501056 421<br />

*Polypropylene sample tray.<br />

AS-91<br />

Capacity Sample Vessel Size Part No. Each (€)<br />

Tray E-218 4.5 mL, 6 mL, 8 mL B0509554 440<br />

Tray F-152 15 mL, 16 mL B0509555 440<br />

Tray G-55 50 mL B0508520 440<br />

Trays A, C, E, F, and G are powder-coated, corrosion-resistant aluminum.<br />

AS-93plus<br />

Capacity Sample Vessel Size Part No. Each (€)<br />

9/29 50 mL/15 mL B3001647 26<br />

30 50 mL B3140621 26<br />

60 15 mL, 16 mL B3140618 26<br />

90 4.5 mL, 6 mL, 8 mL B3140617 26<br />

AS-93plus sample trays are polypropylene.<br />

Part No.<br />

Each (€)<br />

B3140236 292<br />

B3000166 185<br />

Sample Vessels<br />

AS-90/90A/<br />

90plus/91/93plus<br />

Translucent polypropylene<br />

vessels with excellent<br />

chemical resistance.<br />

Sample Vessel Volume Quantity Part No. Each (€)<br />

4.5 mL 1000 N9301204 75<br />

6 mL** 500 B0193235 325<br />

8 mL 1000 B0508901 453<br />

15 mL** 500 B0193233 325<br />

16 mL 1000 N9301205 93<br />

50 mL** 500 B0193234 257<br />

** Includes screw caps.<br />

Caps, for 8 mL Vessels<br />

Package of 1000.<br />

AS-90/91 Wash Vessel, Polypropylene<br />

Includes cover (250 mL).<br />

Tubes and Beakers<br />

AS-50/51<br />

AS-93plus<br />

Part No.<br />

Each (€)<br />

B0508902 153<br />

Part No.<br />

Each (€)<br />

B0501258 36<br />

Description Part No. Each (€)<br />

Polystyrene Test Tubes 00471441 32<br />

Cone-shaped bottoms permit use of small<br />

samples. Clear, affordable polystyrene is<br />

recommended for use with most aqueous<br />

solutions (125 test tubes)<br />

Berzelius Tall-form Beaker 00471440 6<br />

Pyrex ® beaker (400 mL) used as a wash<br />

vessel for the autosampler<br />

8


Sampling Probe Assemblies,<br />

AS-90/90A/90plus/91/93plus<br />

Autosamplers automate standard and sample introduction<br />

for instrument calibration and sample analysis via software<br />

commands, extending the spectrometer’s capabilities to<br />

those of a fully-automated analytical workstation.<br />

Stainless Steel Probe<br />

Part No. B3000152<br />

Stainless Steel<br />

Description Part No. Each (€)<br />

Sampling Probe Assembly, B3000159 198<br />

0.6 mm i.d.<br />

Stainless steel sampling probe and screw fitting, B3000152,<br />

and flame capillary tubing assembly, B3000157.<br />

Sampling Probe Assembly, B3000160 198<br />

0.6 mm i.d.<br />

Stainless steel sampling probe and screw fitting, B3000152<br />

and FIAS TM capillary tubing assembly B3000158.<br />

Standard Sampling Probe Assembly, B3000161 198<br />

1.0 mm i.d.<br />

Stainless steel sampling probe and screw fitting, probe B3000152,<br />

and FIAS capillary tubing assembly B0191060.<br />

Corrosion-Resistant<br />

Description Part No. Each (€)<br />

Flame Sampling Probe Assembly, B3001770 217<br />

0.6 mm i.d.*<br />

Corrosion-resistant probe, suitable for inorganic acids and most organic<br />

solvents, except NMP. Includes sampling probe with FEP tube and screw<br />

fitting (B3000055) and capillary tubing assembly (B3000157).<br />

Sampling Probe Assembly, B3001771 198<br />

0.6 mm i.d.*<br />

Corrosion-resistant probe, suitable for inorganic acids and most organic<br />

solvents, except NMP. Includes sampling probe with FEP tube and screw<br />

fitting (B3000055) and capillary tubing assembly (B3000158).<br />

Standard Sampling Probe Assembly, B3001772 217<br />

1.0 mm i.d.*<br />

Corrosion-resistant probe, suitable for inorganic acids and most organic<br />

solvents, except NMP. Includes sampling probe with FEP tube and screw<br />

fitting (B3001769), and capillary tubing assembly (B0191060).<br />

* Probe cannot be used with AS-90s, which have the older sampling probe holder.<br />

Autosampler Supplies and Accessories<br />

Autosampler Flame/FIAS Probes<br />

Sampling Probe Assembly Components,<br />

AS-90/90A/90plus/91/93plus<br />

Corrosion-Resistant Sampling Probes<br />

with Screw Fitting<br />

Suitable for inorganic acids and most organic solvents,<br />

except NMP. Requires, but does not include, one of the<br />

capillary tubing assemblies described below.<br />

Description ID Part No. Each (€)<br />

Corrosion-Resistant Sampling Probe 0.6 mm B3000055 134<br />

Corrosion-Resistant Sampling Probe 1.0 mm B3001769 97<br />

Stainless Steel Sampling Probe w/Screw Fitting<br />

Requires, but does not include,<br />

one of the capillary tubing<br />

assemblies described below.<br />

Capillary Tubing Assembly<br />

Depending on the autosampler application, the sampling<br />

probe can be equipped with any of three types of capillary<br />

tubing assembly, which have different tubing diameters and<br />

either one or two screw fittings.<br />

Description Part No. Each (€)<br />

1 m length, 0.6 mm i.d., one fitting B3000157 40<br />

1 m length, 0.6 mm i.d., two fittings B3000158 18<br />

1 m length, 1.0 mm i.d., two fittings B0191060 19<br />

Used Oil Autosampler Probe<br />

Autosampler probe for the AS-90plus and the AS-93plus<br />

Autosamplers. The probe includes a<br />

particulate filter on the tip to remove<br />

fibers. For use in used oil analysis.<br />

Part No.<br />

N0771529<br />

Each (€)<br />

249<br />

Sampling Probes, AS-50/51<br />

Stainless Steel Sampling Probe<br />

For use with both aqueous<br />

and organic samples. (pkg. 5)<br />

Platinum/Rhodium Sampling Probe**<br />

Accessory probe recommended for use<br />

when samples corrosive to stainless<br />

steel are being analyzed. (pkg. 1)<br />

Quartz Sampling Probes***<br />

Probe recommended for use when<br />

samples corrosive to stainless steel<br />

are being analyzed. (pkg. 5)<br />

Sampling Probe Cleaning Wire (1 M)<br />

For AS-90/91/90plus/93plus probe.<br />

Part No.<br />

Part No.<br />

Each (€)<br />

B3000152 143<br />

Part No.<br />

** Not recommended for use with samples containing aqua regia.<br />

*** Cannot be used with samples containing hydrofluoric acid or other<br />

reagents corrosive to quartz.<br />

Sampling Probe Supplies<br />

Each (€)<br />

00471422 18<br />

Part No.<br />

Each (€)<br />

00471420 363<br />

Part No.<br />

Each (€)<br />

N0580540 112<br />

Each (€)<br />

B0505962 42<br />

Autosampler Supplies and Accessories Atomic Absorption<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

9


Atomic Absorption Autosampler Supplies and Accessories<br />

Autosampler Supplies and Accessories<br />

Dilution System Supplies<br />

AutoPrep 50<br />

1<br />

1<br />

2<br />

AutoPrep 50 Tubing<br />

4 4<br />

5<br />

3<br />

AutoPrep 50<br />

The AutoPrep TM 50 provides automatic, intelligent on-line<br />

dilution capabilities for flame Atomic Absorption.<br />

Key features of the AutoPrep 50 include:<br />

■ Fully automatic sample introduction<br />

■ Automatic intelligent selection of dilution range<br />

■ Automatic preparation of multiple standards from<br />

a single stock solution<br />

■ Integrated software control<br />

Diluter Parts<br />

Description Part No. Each (€)<br />

Pump Assembly, 5 mL B3141052 103<br />

(includes pump head and piston assembly)<br />

Sample Holding Coil, 5 mL B3140123 117<br />

Valve 1 (V1, 3-port with red mark) B3002072 40<br />

Valve 2 (V2, 3-port with yellow mark) B3002094 40<br />

Valve 3 (V3, 3-port with black mark) B3002076 41<br />

Valve 4 (V4, 3-port with black mark) B3002091 40<br />

T-union (T1, black mark) B3002097 45<br />

Thumbscrew for Valves and T-union B3140211 26<br />

Thumbscrew for Sample Holding Coil B3140210 26<br />

Sampling Probe for AS 90/91, complete, B3140244 124<br />

connects AS 90/91 to AutoPrep 50 Valve 3<br />

Nuts and Ferrules<br />

Description Part No. Each (€)<br />

Front Ferrule for 2.4 mm o.d. tubing (B0017998) B3001333 11<br />

Back Ferrule for 2.4 mm o.d. tubing (B0017998) B3001334 10<br />

Nut for 2.4 mm o.d. tubing (B0017998) B3001335 7<br />

Front Ferrule for 1.6 mm o.d. tubing (B0029792) 09920123 19<br />

Back Ferrule for 1.6 mm o.d. tubing (B0029792) 09920124 16<br />

Nut for 1.6 mm o.d. tubing (B0029792) B0080333 7<br />

Tubing<br />

1<br />

2<br />

3<br />

4<br />

5<br />

Description Part No. Each (€)<br />

Diluent and Waste Tube B3140226 40<br />

(connects to V1 or V4), complete,<br />

1.7 mm i.d., 2.4 mm o.d., 1.2 m long<br />

Diluent Feed Tube (connects to V2), B3140227 34<br />

complete 1.0 mm i.d.,<br />

1.6 mm o.d., 0.7 m long<br />

PTFE Tubing B0509652 3<br />

(connects the T-union with the<br />

nebulizer) 0.56 mm i.d., 1.67 mm o.d.<br />

PTFE Tubing, used to interconnect B0029792 2<br />

valves, 1.0 mm i.d., 1.6 mm o.d.<br />

PTFE Tubing, used to connect the<br />

sample pump to the valve (V1), B0017998 3<br />

1.7 mm i.d., 2.4 mm o.d.<br />

Tubing Cutter B3000019 43<br />

10


Autosampler Sample Cups<br />

■<br />

■<br />

Autosampler Supplies and Accessories<br />

Graphite Furnace Autosampler Supplies for the AS-40/60/70/71/72/800<br />

Heavy-duty construction prevents cracking or tipping<br />

Conical design allows for use of entire sample<br />

Your choice of materials:<br />

Polystyrene – Clear, recommended for use with most<br />

aqueous solutions.<br />

Polyethylene – Translucent, low density, recommended<br />

for use with most aqueous and organic solutions.<br />

Teflon ® – Recommended for use with most concentrated<br />

acids including HF and for analyses where the lowest<br />

detection levels are required.<br />

Polypropylene – Translucent. No known solvent at<br />

room temperature.<br />

Graphite Furnace Autosampler Cups<br />

Volume Composition Qty. Part No. Each (€)<br />

7 mL**** Polypropylene 100 B3001567 33<br />

3.5 mL** Polystyrene 100 B0129303 34<br />

2.5 mL** Polypropylene 1000 B3001566 47<br />

2 mL* Polyethylene 1000 B0087056 53<br />

2 mL* Polystyrene 1000 B0119079 82<br />

2 mL* Teflon 30 B0087600 242<br />

1.2 mL*** Polypropylene 2000 B0510397 61<br />

* For use with AS-40/60/70/71/72/800 *** For use with AS-71/72/800<br />

** For use with AS-60/70/71/72/800 **** For use with AS-800<br />

Pliers<br />

For 1.2 mL sample cups.<br />

148-Position Tray, Polypropylene<br />

(For Model AS-800)<br />

Part No. B3001506<br />

Part No.<br />

Each (€)<br />

B0510398 11<br />

88-Position Tray, Polypropylene<br />

(For Model AS-800)<br />

Part No. B3001507<br />

Autosampler Trays<br />

Description Part No. Each (€)<br />

For Model AS-40<br />

Sample Tray B0101045 459<br />

For Models AS-60/70<br />

Sample Tray* B0510417 66<br />

For Models AS-71/72<br />

40-Position Tray, Plastic B0510417 66<br />

35 sample locations for 2 or 3.5 mL sample cups*<br />

80-Position Tray, Plastic B0510404 41<br />

75 sample locations for 1.1 mL sample cups*<br />

Sample Tray Cover B3001330 23<br />

For Model AS-800<br />

88-Position Tray, Polypropylene B3001507 21<br />

80 sample locations for 2, 2.5, or 3.5 mL sample<br />

cups. Each sample tray also has eight positions<br />

for 7 mL reagent containers.<br />

148-Position Tray, Polypropylene B3001506 21<br />

132 sample locations for 1.1 mL sample cups<br />

and eight locations for 2.5 or 3.5 mL sample<br />

cups. Each sample tray also has eight positions<br />

for 7 mL reagent containers.<br />

AS-800 Supplies<br />

Arm B3002046 8<br />

Sampling Arm Collar B3001465 14<br />

Set Screw for Collar B0055900 1<br />

Sample Tray Cover B3001505 17<br />

* Each sample tray has five positions for 30 mL<br />

cloverleaf-shaped reagent containers<br />

Check Valves<br />

Description Part No. Each (€)<br />

Inlet (complete) B3002007 267<br />

Includes ferrules and connector<br />

Outlet (complete) B3002006 267<br />

Includes ferrules and connector<br />

Solvent-Resistant Check Valves<br />

Description Part No. Each (€)<br />

Inlet B0105973 437<br />

Outlet B0105974 359<br />

Autosampler Supplies and Accessories Atomic Absorption<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

11


Autosampler Supplies and Accessories<br />

Atomic Absorption Autosampler Supplies and Accessories<br />

Graphite Furnace Autosampler Supplies for the AS-40/60/70/71/72/800<br />

AS-800 Autosampler<br />

Ferrule Kits<br />

Rinse Tubing Ferrules<br />

Description Size Part No. Each (€)<br />

Front Ferrule 2.45 mm i.d. B3001333 11<br />

Rear Ferrule 2.45 mm i.d. B3001334 10<br />

Sample Tubing Ferrule Kit (1.6 mm i.d.)<br />

Used with B0129258 and<br />

B0101161 sampling capillaries.<br />

Contains 5 front and 5 rear ferrules.<br />

Tubing Only (PTFE)*<br />

Description Size Part No. Each (€)<br />

Rinse Tubing 1.6 mm o.d. B0029792 2<br />

Sample Tubing 2.45 mm o.d. B0017998 3<br />

* Order per meter.<br />

Part No.<br />

Each (€)<br />

B0086142 68<br />

Sampling Capillary<br />

(For Models AS-60/70/71/72/800)<br />

Part No. B0129258<br />

Reagent Containers<br />

For Models AS-40/60/70/71/72<br />

Round Reagent Containers<br />

For blank solutions, reagent solutions, or matrix modifiers.<br />

Volume Composition Part No. Each (€)<br />

20 mL PTFE* B0103037 40<br />

20 mL Polypropylene** B0101164 10<br />

25 mL Polystyrene*** B0102332 5<br />

* Solvent-resistant (AS-40 only)<br />

** Suitable for organic solutions<br />

*** Not suitable for organic solutions<br />

For Models AS-60/70/71/72<br />

Cloverleaf-Shaped<br />

Reagent Containers<br />

30 mL polypropylene.<br />

■ Resists most acid solutions<br />

■ Provides more reagent volume, yet<br />

occupies only one sample space<br />

■ Allows you to insert up to five<br />

different reagent solutions<br />

or matrix modifiers for one run<br />

Rinse Solution Bottle (2 L)<br />

Waste Solution Bottle (2 L)<br />

Sampling Capillaries<br />

■<br />

■<br />

■<br />

Solvent- and acid-resistant sampling components<br />

PTFE pipette tips and capillaries for reduced contamination<br />

Easy replacement<br />

Part No.<br />

Each (€)<br />

B0132799 34<br />

Part No.<br />

Each (€)<br />

B0104281 110<br />

Part No.<br />

Each (€)<br />

B0104987 41<br />

Description Part No. Each (€)<br />

For Model AS-40<br />

Sampling Capillary B0101161 242<br />

For Models AS-60/70/71/72/800<br />

Sampling Capillary B0129258 242<br />

12


Burner System Components<br />

AAnalyst 100/200/300/400/700/800<br />

Burner Heads<br />

AAnalyst Burner Heads cannot be used with other PerkinElmer<br />

AA Spectrometers.<br />

A Single-Slot Nitrous Oxide-Acetylene<br />

The 5 cm nitrous oxide burner head is required<br />

for nitrous oxide-acetylene operation. This<br />

burner head can also be<br />

used with air-acetylene<br />

or rotated to provide<br />

reduced sensitivity.<br />

Part No.<br />

N0400100<br />

Each (€)<br />

982<br />

A<br />

A<br />

A<br />

Single-Slot Air-Acetylene<br />

The 10 cm burner head is designed to be used<br />

with the air-acetylene flame. Because of its<br />

long burner path length, it provides the best<br />

sensitivity for airacetylene<br />

elements.<br />

Part No. Each (€)<br />

N0400102 982<br />

Three-Slot Air-Acetylene<br />

The three-slot burner head (10 cm) is designed<br />

to be used when analyzing samples with high<br />

concentrations of dissolved solids. The threeslot<br />

burner head is not<br />

compatible with some<br />

older gas control systems.<br />

Part No.<br />

N0400103<br />

Each (€)<br />

982<br />

Single-Slot Air-Acetylene<br />

A 5 cm air-acetylene burner head (5 cm) is<br />

available for applications in which reduced<br />

sensitivity is required. It can be rotated to<br />

provide further sensitivity<br />

reduction, and it has a wide<br />

slot to prevent clogging.<br />

Part No.<br />

N0400101<br />

Each (€)<br />

982<br />

Burner Head Cleaning Tool<br />

6<br />

G1<br />

7<br />

2<br />

2<br />

5<br />

3<br />

1<br />

4<br />

3<br />

D<br />

G2<br />

Part No.<br />

Each (€)<br />

03031573 3<br />

F<br />

E<br />

A<br />

C<br />

B<br />

Burner System Components<br />

B<br />

C<br />

D<br />

E<br />

F<br />

G1<br />

G2<br />

Components Part No. Each (€)<br />

Viton Burner Head O-Ring 09902219 2<br />

Burner Mixing Chamber Assembly 00570948 402<br />

Clamping Ring N0401171 26<br />

Flow Spoiler 00572561 20<br />

End Cap O-Ring<br />

Aqueous (Viton) 09902147 2<br />

Organics (Corkprene) 00472014 3<br />

Aqueous and Organics (KALREZ ® )* 09921044 266<br />

End Cap Assembly N0370392 287<br />

Used with the following nebulizers:<br />

03030352, 03030404, 03030299.<br />

End Cap Assembly 00570984 440<br />

Used with the following nebulizers:<br />

B0505480, B0505590, N0370394,<br />

N0370393, N3150188.<br />

* Recommended for use when determination of organic and acid based<br />

solutions required<br />

Impact Bead and Retainer Assembly<br />

This can only be used with the End Cap Assembly<br />

(Part No. 00570984).<br />

Description Part No. Each<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

Seal Plug 00572624 38<br />

Large Impact Bead O-Ring 09902240 3<br />

O-Ring (1/8 in.) 09902236 2<br />

Impact Bead 00572615 70<br />

Impact Retainer 00572695 30<br />

Split Lockwasher 09911286 1<br />

Binding Head Screw 09910148 1<br />

Burner Gasket Kit 00470988 71<br />

Includes: Kit Qty. Part No. Each (€)<br />

Corkprene End Cap O-Ring 5 00472014 3<br />

Viton End Cap O-Ring 3 09902147 2<br />

Viton Burner Head O-Ring 1 09902219 2<br />

Small Impact Bead O-Ring 3 09902236 2<br />

Large Impact Bead O-Ring 3 09902240 3<br />

Magnet Assembly for AAnalyst N2010381 32<br />

700/800<br />

Magnet Assembly for AAnalyst N1010215 32<br />

100/200/300/400<br />

Drain Components<br />

Components Part No. Each (€)<br />

Drain Tubing, AAnalyst 100/200/300/400/700/800 02507987 22<br />

AAnalyst 700/800 Drain Assembly N2011074 1346<br />

AAnalyst 100/300 Drain Assembly N0400058 779<br />

Drain Bottle 09904991 112<br />

(€)<br />

Burner System Components Atomic Absorption<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

13


Burner System Components<br />

Models 2280, 2380, 3030(B), 3100, 3110, 3300, 4000*, 5000*, and 5100 PC<br />

Burner Heads<br />

Burner Gasket Kit<br />

Part No. Each (€)<br />

00470988 71<br />

Atomic Absorption Burner System Components<br />

E1<br />

E2<br />

E3<br />

E1<br />

Single-slot Burner Head 00400266 893<br />

The 10 cm burner head is designed to be used with the<br />

air-acetylene flame. Because of its long burner path length,<br />

it provides the best sensitivity for air-acetylene elements.<br />

Nitrous Oxide Burner Head 00400277 867<br />

The 5 cm nitrous oxide burner head is required for nitrous<br />

oxide-acetylene operation. This burner head can also be used<br />

with air-acetylene or rotated to provide reduced sensitivity.<br />

Three-slot Burner Head 00400289 867<br />

The three-slot burner head is designed to be used when<br />

analyzing samples with high concentrations of dissolved solids.<br />

The three-slot burner head is not compatible with<br />

some older gas control systems.<br />

Burner Head Cleaning Tool 03031573 3<br />

Burner System Components<br />

1<br />

2<br />

3<br />

4<br />

5<br />

A<br />

B<br />

C<br />

Components Part No. Each (€)<br />

Viton Burner Head O-Ring 09902219 2<br />

Aqueous Viton End Cap O-Ring 09902147 2<br />

Organic (Corkprene) End Cap O-Ring 00472014 3<br />

Aqueous/Organic (Kalrez) 09921044 266<br />

End Cap O-Ring<br />

Clamping Ring 00572616 78<br />

Stainless Steel Locking Ring 00572737 107<br />

Use N0371071 for Models 3300,<br />

3110, and 3100<br />

End Cap Assembly** 00570984 440<br />

Flow Spoiler 00572561 20<br />

Burner Mixing Chamber 00570948 402<br />

Impact Bead Assembly<br />

D<br />

6<br />

7<br />

8<br />

9<br />

10<br />

11<br />

Impact Bead 00572615 70<br />

Seal Plug 00572624 38<br />

O-Ring (1/4 in./6 mm i.d.) 09902240 3<br />

O-Ring (1/8 in./3 mm i.d.) 09902236 2<br />

Impact Retainer 00572695 30<br />

Split Lockwasher 09911286 1<br />

Binding Head Screw 09910148 1<br />

* For use on models 4000 and 5000 shipped after May 1980<br />

** A different end cap assembly, N0370392, is required for use<br />

with the high-sensitivity nebulizer<br />

E3<br />

E2<br />

Includes: Kit Qty. Part No. Each (€)<br />

Corkprene End Cap O-Ring 5 00472014 3<br />

Viton End Cap O-Ring 3 09902147 2<br />

Viton Burner Head O-Ring 1 09902219 2<br />

Small Impact Bead O-Ring 3 09902236 2<br />

Large Impact Bead O-Ring 3 09902240 3<br />

Burner Drain Assembly 00470391 236<br />

Includes Drain Loop and Interlock only, for Models 2280, 2380, 3030(B),<br />

4000, 5000, and 5100 PC.<br />

Burner Drain Assembly N0370149 252<br />

Includes Drain Loop and interlock only, for Models 3100, 3110, and 3300.<br />

Cable and Pin Assemblies<br />

Components Part No. Each (€)<br />

For Air-Acetylene Burner Head (short pin) 00400276 56<br />

For Nitrous Oxide Burner Head (long pin) 00400275 56<br />

Hold Down Cable 03030130 10<br />

A<br />

11<br />

2<br />

10<br />

7<br />

3<br />

4<br />

B<br />

9<br />

7<br />

8<br />

6<br />

1<br />

8<br />

C<br />

D<br />

5<br />

E<br />

14


Burner System Components<br />

Models 1100(B), 2100, and 4100<br />

Burner Heads<br />

E<br />

E<br />

Single-Slot Burner Head B0162668 918<br />

The 10 cm burner head is designed to be used with<br />

the air-acetylene flame. Because of its long burner<br />

path length, it provides the best sensitivity for<br />

air-acetylene elements.<br />

Nitrous Oxide Burner Head B0162669 1530<br />

The 5 cm nitrous oxide burner head is required for<br />

nitrous oxide-acetylene operation. This burner head<br />

can also be used with air-acetylene or rotated to<br />

provide reduced sensitivity.<br />

Burner Head Cleaning Tool 03031573 3<br />

Burner System Components<br />

Components Part No. Each (€)<br />

91 Viton Burner Head O-Ring 09902219 2<br />

10 2 Aqueous End Cap O-Ring B0158690 11<br />

11 3 Organic (Corkprene) End Cap O-Ring B0158598 7<br />

4 Hold Down Wire (Pkg. 1, not shown) B0160697 47<br />

B5 Flow Spoiler 00572561 20<br />

C6 Burner Mixing Chamber B0153250 523<br />

F7 Impact Bead Assembly B0151579 580<br />

G8 Impact Bead, Ceramic B0158616 79<br />

A H End Cap and Drain Interlock Assembly B0151573 561<br />

BI<br />

Insert B0157117 38<br />

JC Clamping Ring B0162671 226<br />

Aqueous Burner Gasket Kit Assembly B0155546 210<br />

For Aqueous Solutions.<br />

Includes: Kit Qty. Part No. Each (€)<br />

Viton Burner Head O-Ring 1 09902219 2<br />

Aqueous End Cap O-Ring 1 B0158690 11<br />

Corkprene End Cap O-Ring 5 B0158598 7<br />

Plug O-Ring (Aqueous) 2 B0151697 1<br />

O-Ring between End Cap and Drain Vessel 1 B0129926 1<br />

Organic Burner Gasket Kit Assembly B0173404 848<br />

For Organic Solutions. Includes Gaskets, O-Rings, and Seals for the<br />

Models 4100, 2100, or 1100(B). Delivered in convenient storage box.<br />

Includes: Kit Qty. Part No. Each (€)<br />

Plug O-Ring 3 B0174378 56<br />

O-Ring and Drain 1 B0174379 50<br />

End Cap Gasket 1 B0174380 45<br />

O-Ring and Bead Holder Assembly 1 B0181842 57<br />

O-Ring on Nebulizer Venturi 1 B0190001 45<br />

O-Ring, High-Sensitivity Nebulizer 1 B0190672 29<br />

Drain Tube (2 m) 1 B0102949 12<br />

H<br />

10<br />

11<br />

J<br />

B<br />

Burner Head Cleaning Tool<br />

Part No. 03031573<br />

F<br />

9<br />

I<br />

C<br />

E<br />

G<br />

Burner System Components Atomic Absorption<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

15


Burner System Components<br />

Nebulizers<br />

Atomic Absorption Burner System Components<br />

PerkinElmer nebulizers are available in a variety of<br />

configurations to meet all of your analytical needs.<br />

The nebulizer is one of the most important components in<br />

a flame AA spectrometer. Sample solutions, with differing<br />

physical properties, must be converted into an aerosol of<br />

small, similarly sized droplets. This places great demands<br />

on the design of the nebulizer.<br />

All PerkinElmer nebulizer assemblies are adjustable for<br />

optimized performance and include easily interchanged<br />

capillary assemblies for simple, reduced-cost maintenance.<br />

PerkinElmer nebulizers are manufactured to exacting tolerances<br />

to provide maximum sensitivity. Universal, or “standard,”<br />

nebulizers are less expensive than the corresponding highsensitivity<br />

nebulizers and provide a lower level of sensitivity.<br />

The universal, or “standard,” nebulizers typically provide<br />

better precision and reduced “carryover” interference when<br />

used with solutions that contain high dissolved solids and<br />

content of higher analyte concentrations.<br />

Corrosion-Resistant Nebulizer<br />

For all solutions containing hydrofluoric acid or aqua regia<br />

For all solutions containing high concentrations of<br />

dissolved solids<br />

All internal components in contact with solutions are<br />

constructed of plastic to resist corrosion from<br />

concentrated acids<br />

Reduced performance compared with stainless steel or<br />

platinum/rhodium nebulizers<br />

GemTip Nebulizer<br />

Corrosion-resistant and can be used to aspirate almost<br />

all solutions, even those solutions containing a high<br />

percentage of acids<br />

Designed to obtain optimum sensitivity, detection limits,<br />

and precision with flame atomic absorption for both<br />

air-acetylene and nitrous oxide-acetylene flames<br />

High-Sensitivity Nebulizers<br />

Provide maximum sensitivity, precision, and freedom<br />

from analytical interferences<br />

The high-sensitivity nebulizer with platinum/iridium<br />

capillary is for most solutions, but not for precious metal<br />

samples containing aqua regia<br />

High-sensitivity nebulizer with tantalum capillary used<br />

for solutions containing aqua regia<br />

Platinum Alloy Nebulizer<br />

Recommended for most concentrated acids<br />

containing >5% acid<br />

Includes a platinum alloy needle assembly and a<br />

tantalum venturi<br />

Provides maximum chemical resistance<br />

Not suitable for use with aqua regia or hydrofluoric acid<br />

Stainless Steel Nebulizer<br />

For most solutions containing


Burner System Components<br />

Nebulizer Assemblies and Components Quick Reference<br />

Plastic Body Nebulizers<br />

For AAnalyst 100/300/700/<br />

For AAnalyst 800, Models 3100/3110/3300/<br />

200/400 5000/5100 PC and Earlier AAs 1100(B)/2100/4100<br />

GemTip Nebulizer (see page 18) Part No. Each (€) Part No. Each (€) Part No. Each (€)<br />

D<br />

F<br />

E<br />

A<br />

D<br />

F<br />

C<br />

E<br />

Stainless Steel Body Nebulizers<br />

A<br />

B<br />

A<br />

B<br />

A<br />

GemTip Nebulizer Assembly 3 N0370394 663<br />

High-Sensitivity GemTip Nebulizer Assembly 3 N0370393 1167<br />

High-Sensitivity Nebulizer with Pt/Ir Capillary 4 (see page 19) Part No. Each (€) Part No. Each (€) Part No. Each (€)<br />

C<br />

Nebulizer Assembly 3 N3150188 423 B0505480 1518 B0501029 1518<br />

Nebulizer End Cap Nut B0501026 7 B0501026 7<br />

Nebulizer Spacer 09902015 6<br />

Nebulizer Body B0506666 166 B0506668 166<br />

Impact Bead B0505086 63 B0505086 63 B0505086 63<br />

Locking Ring B0501025 7 B0501025 7<br />

Capillary Assembly B0501022 242 B0501022 242<br />

High-Sensitivity Nebulizer with Tantalum Capillary 4 (see page 19) Part No. Each (€) Part No. Each (€) Part No. Each (€)<br />

A<br />

Nebulizer Assembly 3 B0505590 1734 B0505589 1734<br />

Nebulizer End Cap Nut B0501026 7 B0501026 7<br />

Nebulizer Body B0506666 166 B0506668 166<br />

Capillary Assembly B0505588 599 B0505588 599<br />

Impact Bead B0505086 63 B0505086 63<br />

Locking Ring B0501025 7 B0501025 7<br />

Corrosion-Resistant Nebulizer 1 Part No. Each (€) Part No. Each (€) Part No. Each (€)<br />

Nebulizer Assembly 03030404 752 N3110110 1167<br />

Capillary Assembly 03030402 242 03030402 242<br />

Capillary Assembly for AS-51 or AS-50 00570957 236 00570957 236<br />

O-Ring Kit N9300065 84 N9300066 84<br />

Venturi 03031920 134 03031920 134<br />

Platinum Alloy Nebulizer 1 Part No. Each (€) Part No. Each (€) Part No. Each (€)<br />

Nebulizer Assembly 03030299 1059 N3110111 1518<br />

Capillary Assembly 2 03030433 395 03030433 395<br />

O-Ring Kit N9300065 84 N9300066 84<br />

Venturi 03033124 536 N3111158 854<br />

Stainless Steel Nebulizer 1 (see page 20) Part No. Each (€) Part No. Each (€) Part No. Each (€)<br />

Nebulizer Assembly 03030352 606 N3110109 1001<br />

Capillary Assembly 03030354 134 03030354 134<br />

O-Ring Kit N9300065 84 N9300066 84<br />

B Venturi 03031810 134 B0166503 111<br />

1 - Stainless steel body 2 - Etched with a “P” for identification 3 - Requires End Cap Assembly (N0370392) 4 - Inert plastic body with red adjusting ring<br />

Burner System Components Atomic Absorption<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

17


Burner System Components<br />

Nebulizers and Components<br />

Accessories<br />

Atomic Absorption Burner System Components<br />

Nebulizer Capillary Tubing<br />

10 ft. (3 m) length of 0.58 mm i.d.<br />

polyethylene tubing, for use with<br />

the stainless steel, platinum/<br />

rhodium and GemTip TM Nebulizers.<br />

Not suitable for corrosion-resistant<br />

nebulizers where capillary tubing is<br />

part of capillary<br />

Part No. Each (€)<br />

assembly. Not<br />

compatible with N3150188 Nebulizer. 09908265 29<br />

Nebulizer Cleaning Wires<br />

GemTip Nebulizers<br />

GemTip Nebulizer<br />

1<br />

2<br />

3<br />

4<br />

11<br />

5<br />

10<br />

Made of soft alloy copper,<br />

these cleaning wires are<br />

specially deburred to prevent<br />

scratching of the orifices and<br />

internal components of the<br />

nebulizers while cleaning.<br />

Use only PerkinElmer<br />

cleaning wires to clean<br />

nebulizers. (pkg. 5)<br />

6<br />

9 8<br />

13<br />

Part No.<br />

12<br />

7<br />

Each (€)<br />

03030135 17<br />

For AAnalyst TM 100/300/700/800*<br />

Description Part No. Each (€)<br />

Universal GemTip Assembly Complete** N0370394 663<br />

High-Sensitivity GemTip Assembly Complete** N0370393 1167<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

9<br />

10<br />

11<br />

12<br />

13<br />

Nebulizer Grease<br />

A small quantity of Apiezon ® -L<br />

grease helps to lubricate the<br />

O-Ring seals for reassembly and<br />

ensures leak-proof operation. A<br />

tube of grease is supplied with<br />

each complete nebulizer assembly.<br />

However, you should order the tube if you purchase separate<br />

capillary and venturi sections.<br />

Part No. Each (€)<br />

03030405 9<br />

Component Part No. Each (€)<br />

Capillary Tubing 09908265 29<br />

Adjustment Nut N0371492 25<br />

Gland Nut N0371505 13<br />

Teflon Tubing 09985708 7<br />

Capillary Holding Assembly*** N0371520 223<br />

Capillary Holding Assembly**** N0371522 223<br />

O-Ring 09926083 10<br />

Impact Bead***** B0505086 63<br />

O-Ring 09902015 6<br />

O-Ring****** B0174378 56<br />

Body Assembly*** N0370398 402<br />

Body Assembly**** N0370399 427<br />

Locking Nut N0371493 12<br />

Spring 09902473 1<br />

Connector Nut N0371485 13<br />

Magnet Holder Assembly N1010215 32<br />

* Shipped before Fall 1999<br />

** Requires End Cap Assembly (N0370392)<br />

*** For Universal GemTip Nebulizers<br />

**** For high-sensitivity GemTip Nebulizers<br />

***** Included with high-sensitivity GemTip Nebulizer only<br />

****** Organic Resistant<br />

18


Burner System Components<br />

Nebulizers and Components<br />

High-Sensitivity Nebulizers*<br />

For Models AAnalyst 100/300/700/800/<br />

1100(B)/2100/3100/3110/4100/5100 PC<br />

Description Part No. Each (€)<br />

High-Sensitivity Nebulizer Assembly with<br />

Pt/Ir Capillary B0505480 1518<br />

High-Sensitivity Nebulizer Assembly with<br />

Tantalum Capillary B0505590 1734<br />

Components Part No. Each (€)<br />

21 O-Ring B0174378 56<br />

22 Spring B0165332 3<br />

23 O-Ring B0190672 29<br />

A / C / D / E / F See chart on page 17<br />

* Requires End Cap (N0370392)<br />

High-Sensitivity Nebulizer<br />

with Pt/Ir Capillary<br />

For Models AAnalyst 200/400/700*/800*<br />

Description Part No. Each (€)<br />

High-Sensitivity Nebulizer Assembly with<br />

Pt/Ir Capillary N3150188 423<br />

C<br />

1<br />

Components Part No. Each (€)<br />

Impact Bead Structure B0505086 63<br />

Nebulizer Spacer 09902015 6<br />

* Requires End Cap Assembly (N0370392)<br />

High-Sensitivity Nebulizer<br />

C 21 F<br />

22<br />

23 A E<br />

High-Sensitivity Nebulizer with Pt/Ir Capillary<br />

1<br />

C<br />

D<br />

Burner System Components Atomic Absorption<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

19


Burner System Components<br />

Nebulizers and Components<br />

Stainless Steel Body<br />

Nebulizers and Parts<br />

Atomic Absorption Burner System Components<br />

Stainless Steel Nebulizer<br />

1<br />

2<br />

6<br />

7<br />

11<br />

12<br />

16<br />

17<br />

8<br />

18<br />

3<br />

13<br />

1<br />

A<br />

11<br />

A<br />

B<br />

9<br />

B<br />

19<br />

4<br />

10<br />

14<br />

20<br />

5<br />

15<br />

For Models AAnalyst 100/300/700/800,* 5100 PC,<br />

5000, 3300, 3110, 3100, and Earlier AAs**<br />

Description Part No. Each (€)<br />

Stainless Steel Nebulizer Assembly 03030352 606<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

9<br />

10<br />

A<br />

Description Part No. Each (€)<br />

O-Ring 09902005 1<br />

Insert 03031812 68<br />

Nebulizer Body 03030353 64<br />

Front End Cap 03031808 14<br />

O-Ring 09902239 1<br />

Adjustment Nut 03031460 41<br />

Locking Ring 03031456 9<br />

Washer 03031802 4<br />

O-Ring 09902102 1<br />

Spring 03031806 5<br />

/ B See chart on page 17<br />

* For AAnalyst spectrometers shipped starting Fall 1999<br />

** May be used on AAnalyst 200/400. Requires End Cap (00570984)<br />

For Models 4100, 2100, and 1100(B)<br />

Description Part No. Each (€)<br />

Stainless Steel Nebulizer Assembly N3110109 1001<br />

11<br />

12<br />

13<br />

14<br />

15<br />

16<br />

17<br />

18<br />

19<br />

20<br />

A<br />

Description Part No. Each (€)<br />

O-Ring B0045095 1<br />

Insert B0057336 31<br />

Nebulizer Body B0152456 88<br />

B0166507 159<br />

Front End Cap B0166502 15<br />

O-Ring B0148651 3<br />

Adjustment Nut B0166505 32<br />

B0057408 41<br />

Locking Ring B0166506 13<br />

B0057409 15<br />

Washer B0057334 6<br />

O-Ring B0057761 2<br />

Spring B0057410 5<br />

/ B See chart on page 17<br />

20


Flow Injection Sampling Supplies<br />

Flow Injection Analysis and Mercury Systems<br />

Flow Injection<br />

Analysis Systems (FIAS TM )<br />

PerkinElmer pioneered the use of flow injection techniques<br />

with atomic spectroscopy. The use of flow injection with<br />

AA, ICP, and ICP-MS saves time, costs and manpower,<br />

while at the same time extending your analytical flexibility<br />

and capabilities.<br />

The overall benefits include:<br />

Increased sample throughput<br />

Reduced reagent consumption<br />

Reduced sample volume<br />

Automated cold vapor mercury determinations using U.S.<br />

Environmental Protection Agency-approved methodology<br />

Automated hydride generation determinations<br />

Automated analyte preconcentration<br />

Matrix removal<br />

Automated sample dilution and reagent addition<br />

Enhanced performance for samples<br />

with high dissolved solids content<br />

Flow Injection<br />

Mercury Systems (FIMS TM )<br />

FIMS Tubing Diagram<br />

The Flow Injection Mercury System (FIMS) is an extremely<br />

small and easy-to-operate atomic absorption instrument<br />

dedicated to trace mercury determination. Based on flow<br />

injection techniques, it is fully automated, fast, and costeffective.<br />

FIMS provides exceptional sensitivity, precision,<br />

and detection limits.<br />

FIAS 100<br />

FIMS and Autosampler<br />

Flow Injection Sampling Supplies Atomic Absorption<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

21


Flow Injection Sampling Supplies<br />

FIAS and FIMS Parts and Supplies<br />

Atomic Absorption Flow Injection Sampling Supplies<br />

FIAS Cells and Supplies<br />

Quartz Cell 2 for FI-MHS<br />

Quartz Window<br />

Quartz Window Assembly<br />

Part of Quartz Cell 2.<br />

Universal Quartz Cell Holder<br />

Allows mounting of the FIAS-100/400<br />

Quartz Cell to Models 5100, 3030, 2380,<br />

3300, 3110, 3100, and AAnalyst series.<br />

For use with the electrically heated<br />

cell assembly or an air-acetylene<br />

flame with<br />

suitable mount.<br />

Part No. Each (€)<br />

B0507486 854<br />

Note: If both NaBH 4 and SnCl 2 are to be used as reducing agents with FIAS<br />

systems configured for Hg/hydride determinations, it is strongly recommended<br />

that separate mixing manifolds, gas-liquid separators, quartz cells, and<br />

required tubing and connectors be dedicated for use with each<br />

reducing agent.<br />

FIMS Cells and Supplies<br />

See page 25 for a complete listing of fittings, tubing, and flow injection <strong>supplies</strong>.<br />

Absorption Cell Body<br />

Quartz Window Assembly<br />

Kit Includes: Part No. Each (€)<br />

Window B0066549 21<br />

Holder B3000243 12<br />

FIMS Source Mercury Lamp<br />

Mercury Lamp Extractor<br />

For removing mercury lamp.<br />

Silicone Sleeve<br />

For FIMS Cell Sample Inlet.<br />

Part No.<br />

Each (€)<br />

B0066549 21<br />

Part No.<br />

Each (€)<br />

B0507487 140<br />

Part No.<br />

Each (€)<br />

B3000350 338<br />

Part No.<br />

Part No.<br />

Each (€)<br />

B0510370 84<br />

Each (€)<br />

B0510487 214<br />

Part No.<br />

Each (€)<br />

B3000243 12<br />

Part No.<br />

Each (€)<br />

B0018283 11<br />

Silicone Tubing<br />

For FIMS Cell Exhaust Outlet, 3 m.<br />

Hg Scrubber Kit<br />

Traps mercury vapor from the FIMS system. Eliminates the<br />

need for an expensive exhaust vent.<br />

Recommended by the U.S. EPA.<br />

Included with FIMS-100/400.<br />

Part No.<br />

B3000277<br />

Each (€)<br />

134<br />

Hg Replacement Filter<br />

Gas/Liquid Separator Consumables<br />

Gas/Liquid Separator<br />

Modular ‘building block’-type gas-liquid separator<br />

made from chemically resistant plastic. An<br />

exchangeable PTFE membrane in the screw cap<br />

of the separator prevents liquid from being carried<br />

into the quartz cell or ICP torch when working<br />

with strongly foaming samples.<br />

Part No. Each (€)<br />

(For ICP-MS use B0193772.)<br />

B0507959 147<br />

Mixing Manifold<br />

Modular ‘building block’-type mixing manifold with one<br />

mixing channel and three connections; two inlet, and one<br />

outlet. Made from chemically resistant plastic. Several of these<br />

blocks can be ‘plugged’ together easily<br />

to create a single unit with enhanced<br />

mixing capabilities. Part of B0507957.<br />

Part No.<br />

B0507962<br />

Each (€)<br />

50<br />

Mixing/Separation Assembly<br />

Complete modular unit, consisting of two mixing manifolds<br />

with tubing adapters K and M, a gas-liquid separator with a<br />

PTFE membrane, five spare PTFE<br />

membranes, one PTFE tube (110 mm<br />

long), and one PTFE tube (300 mm long).<br />

Part No.<br />

B0507957<br />

Each (€)<br />

504<br />

Chemifold<br />

For use with Glass Gas/Liquid Separator.<br />

Gas/Liquid Separator Holder<br />

for Glass Separator<br />

Glass Gas/Liquid Separator<br />

PTFE Membrane<br />

For use with the B0507959<br />

Gas/Liquid Separator. (pkg. 50)<br />

Plug Connector<br />

For connection of the mixing manifold<br />

and gas/liquid separator blocks.<br />

Part No.<br />

Each (€)<br />

B0046948 3<br />

Part No.<br />

Each (€)<br />

B3000274 107<br />

Part No.<br />

Each (€)<br />

B0187258 402<br />

Part No.<br />

Each (€)<br />

B0509479 377<br />

Part No.<br />

Each (€)<br />

B0193772 204<br />

Part No.<br />

Each (€)<br />

B0508306 319<br />

Part No.<br />

Each (€)<br />

B0507960 13<br />

22


Flow Injection Sampling Supplies<br />

FIAS and FIMS Parts and Supplies<br />

Pump Magazines<br />

Magazine for Peristaltic Pump<br />

One wide (>2 mm) tubing channel.<br />

Magazine for Peristaltic Pump<br />

Two narrow (


Flow Injection Sampling Supplies<br />

FIAS and FIMS Tubing Adapters and Connectors<br />

Flow Injection Sampling Supplies<br />

Adapters with External Threads<br />

Type Description Part No. Each (€)<br />

K / L<br />

1/4 in. (6.4 mm)<br />

External Screw Thread,<br />

K = 1.8 mm o.d. Nipple. B0507918 14<br />

L = 2.8 mm o.d. Nipple. B0507920 16<br />

M 1/4 in. (6.4 mm) B0507919 15<br />

External Screw Thread,<br />

4 mm o.d. Nipple.<br />

N 1/4 in. (6.4 mm) External B0507949 40<br />

Screw Thread, 0.7 mm o.d.<br />

Pt/lr Capillary Nipple.<br />

Screw Plug B0507921 9<br />

1/4 in. (6.4 mm)<br />

External Screw Thread.<br />

Adapters with Internal Threads<br />

Type Description Part No. Each (€)<br />

Connectors<br />

Type Description Part No. Each (€)<br />

IA Connector with Nipples B0199233 4<br />

for 1.7 to 3.2 mm<br />

i.d. tubes.<br />

IB Connector with Nipples B0196882 1<br />

for 2.4 to 3.2 mm<br />

i.d. tubes.<br />

II Connector with 1/4 in. B0196704 3<br />

(6.4 mm) Internal<br />

Screw Thread.<br />

IIIA T-piece with Nipples B0199035 14<br />

for 1.5 to 2.5 mm<br />

i.d. tubes.<br />

IIIB T-piece with Nipples B0198201 17<br />

for 3.5 to 4.5 mm<br />

i.d. tubes.<br />

A / B<br />

1/4 in. (6.4 mm)<br />

Internal Screw Thread,<br />

A = 1.8 mm o.d. Nipple. B0193342 12<br />

B = 3.3 mm o.d. Nipple. B0506716 40<br />

Screw Connector Tightening Tool<br />

For convenient tightening and loosening<br />

of the screw connectors used with<br />

PTFE tubing assemblies.<br />

Part No. Each (€)<br />

B0501315 47<br />

C 1/4 in. (6.4 mm) B0196850 38<br />

Internal Screw Thread,<br />

4 mm o.d. Nipple.<br />

E 1/4 in. (6.4 mm) B0196857 38<br />

Internal Screw Thread,<br />

for the Quartz Cell.<br />

F 1/4 in. (6.4 mm) Internal B0193873 57<br />

Screw Thread, 0.7 mm o.d.<br />

Pt/lr Capillary Nipple.<br />

G 1/4 in. (6.4 mm) Internal B0501580 71<br />

Screw Thread, Two Nipples<br />

to connect tubes to the<br />

Preconcentration Accessory.<br />

K<br />

II<br />

II<br />

E<br />

I<br />

FIAS-400<br />

K<br />

24


Flow Injection Sampling Supplies<br />

FIAS and FIMS Tubing and Supplies<br />

Peristaltic Pump Tubing<br />

Peristaltic Pump Tubing<br />

Peristaltic pump tubing has a wall thickness of 0.84 mm unless<br />

noted otherwise. Part numbers are for a package of 12 pieces.<br />

i.d. (mm) Color Code Part No. Each (€)<br />

0.76 Black/Black B0506058 37<br />

1.14 Red/Red B0193160 37<br />

1.52 Yellow/Blue B0193161 37<br />

2.06 Violet/Violet B0199034 37<br />

3.18 Black/White B0508310 37<br />

Peristaltic Pump Tubing, Solvent-Resistant<br />

White/white, 0.84 mm i.d.<br />

Resistant to organic solvents. (pkg. 12)<br />

PVC Waste Tubing<br />

3 mm i.d. with 1 mm wall thickness,<br />

no fittings. Price per meter.<br />

Silicone Tubing<br />

1 m x 5 mm i.d., no fittings.<br />

PTFE Tubing, Screw<br />

Connectors, and O-Rings<br />

Part No.<br />

Part No.<br />

The following are part numbers for PTFE tubing, O-Rings,<br />

and screw connectors to prepare tubing assemblies.<br />

Each (€)<br />

B0048139 1<br />

Part No.<br />

Each (€)<br />

B0507692 62<br />

Each (€)<br />

B0018283 11<br />

PTFE Tubing<br />

Part No. B0198097<br />

PTFE Tubing Assemblies<br />

Color<br />

i.d (mm) (Screw Fittings) Length (mm) Part No. Each (€)<br />

1.0 Blue 700 B0191059 29<br />

1.0 Blue 110 B0191058 19<br />

1.0 Blue 300 B0198097 19<br />

1.0 Blue 1000 B0191060 19<br />

1.75 Black 250 B0198099 61<br />

1.75 Black 450 B0198100 61<br />

0.35 White 60 B0501594 34<br />

Flanging Tool<br />

Used with PTFE tubing, screw<br />

connectors, and O-Rings to make<br />

tubing assemblies.<br />

Screw Connectors<br />

Color Description Part No. Each (€)<br />

White For 0.35 mm i.d. PTFE Tubing B0502923 1<br />

Red For 0.5 mm i.d. PTFE Tubing B0181354 1<br />

Green For 0.7 mm i.d. PTFE Tubing B0502924 1<br />

Blue For 1.0 mm i.d. PTFE Tubing B0502925 1<br />

Black For 1.75 mm i.d. PTFE Tubing B0502921 1<br />

Note: These connectors are all the same size.<br />

The color code is a universal system to denote the tubing i.d.<br />

O-Rings<br />

Description Part No. Each (€)<br />

For 0.35 - 1.0 mm i.d. Tubing B0507708 1<br />

For 1.75 mm i.d. Tubing B0045472 1<br />

PTFE Tubing (sold by meter)<br />

Tubing i.d. Part No. Each (€)<br />

0.35 mm B0506060 3<br />

0.5 mm B0507020 3<br />

0.7 mm B0507021 2<br />

1.0 mm B0029792 2<br />

1.75 mm B0017998 3<br />

Sample Loops<br />

Description Part No. Each (€)<br />

200 μL B0194048 36<br />

500 μL B0194049 36<br />

1000 μL B0501000 55<br />

3-D Reaction Coil<br />

3-dimensional reactor, 0.35 i.d.<br />

(two flanged ends).<br />

Part No.<br />

Each (€)<br />

B3000001 198<br />

Part No.<br />

Each (€)<br />

B0501595 64<br />

Flow Injection Sampling Supplies Atomic Absorption<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

25


Flow Injection Sampling Supplies<br />

Flow Injection Amalgamation System<br />

Atomic Absorption Flow Injection Sampling Supplies<br />

Amalgamation System and Supplies<br />

1<br />

1<br />

8<br />

7<br />

6 4<br />

5<br />

2<br />

6 9<br />

3<br />

5<br />

8<br />

5<br />

III<br />

Flow Injection Amalgamation System<br />

Provides increased sensitivity for the determination of<br />

mercury by amalgamation of Hg on a Au/Pt gauze. Mercury<br />

collected is quantitatively released by a controlled, rapid<br />

heating of the gauze.<br />

Part No. Each (€)<br />

B0191090 5100<br />

Components Part No. Each (€)<br />

1 Quartz Tube with Au/Pt Gauze B0193793 395<br />

2 Glass Fiber Filter Holder B0507777 363<br />

3<br />

May be used in place of drying tube<br />

Glass Fiber Filter, pkg. 20 B0507779 27<br />

Drying Tube B0198104 54<br />

54<br />

Wash Flask, 10 mL B0505326 105<br />

6III<br />

Connector, “T”-type B0198201 17<br />

7 Sample Loop, 1000 μL B0501000 55<br />

85<br />

PTFE Tubing B0198099 61<br />

1.75 mm i.d., 250 mm length<br />

86<br />

PTFE Tubing B0198100 61<br />

7<br />

1.75 mm i.d., 450 mm length<br />

Silicone Tubing B0018283 11<br />

8<br />

5 mm i.d., 1 m<br />

Silicone Tubing B0070126 9<br />

3 mm i.d., 1 m<br />

Air Filter B0502706 15<br />

9 One-way Valve B0198111 96<br />

26


Flow Injection Sampling Supplies<br />

Flow Injection Furnace Supplies<br />

FIAS-Furnace Coupling Kit and Supplies<br />

The direct coupling of flow injection with a graphite furnace<br />

atomic absorption automates on-line element preconcentration<br />

in the graphite tube, improving detection limits for the hydrideforming<br />

elements and for mercury by a factor of up to 500.<br />

FIAS-Furnace Coupling Kit<br />

For coupling a FIAS-400 with a 4110 ZL, AAnalyst 400<br />

(with HGA-900), AAnalyst 600, AAnalyst 700, AAnalyst<br />

800, or SIMAA TM 6100/6000 Graphite Furnace System.<br />

The kit consists of a sample transfer tube, a quartz pipette<br />

tip, a 50 mL bottle Iridium standard<br />

solution, and a FIAS-Furnace user guide. Part No. Each (€)<br />

HCl<br />

NaBH 4<br />

P1<br />

P2<br />

Waste<br />

Sample<br />

B3140255 654<br />

FIA Valve<br />

FIAS-Furnace Sample<br />

Transfer Tube*<br />

Quartz Pipette Tip*<br />

20 mm. (pkg.1)<br />

Silicone Tube*<br />

1 m.<br />

* Included in the FIAS-Furnace Coupling Kit (B3140255)<br />

Argon<br />

Flow Diagram for FIAS-Furnace Coupling<br />

Gas/Liquid-Separator<br />

Part No.<br />

Capillary<br />

Graphite Tube<br />

Each (€)<br />

B0509612 119<br />

Part No.<br />

Each (€)<br />

B0510032 35<br />

Part No.<br />

Each (€)<br />

B0029796 4<br />

Flow Injection Sampling Supplies Atomic Absorption<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

27


Flow Injection Sampling Supplies<br />

Flow Injection Preconcentration Kit and Supplies<br />

Atomic Absorption Flow Injection Sampling Supplies<br />

Flow Injection Sampling<br />

Valves and Supplies<br />

2<br />

Peristaltic Pump Tubing<br />

Components Part No. Each (€)<br />

FI Sampling Valve, 5-Port B0507914 714<br />

FI Sampling Valve, 8-Port B0509095 1418<br />

Valve Dismantling Tool B0509590 4<br />

Threaded Plug B0500695 468<br />

To close off port on<br />

5-port valve<br />

Peristaltic pump tubing has a wall thickness<br />

of 0.84 mm unless noted otherwise.<br />

7<br />

8<br />

9<br />

Components Part No. Each (€)<br />

Tubing (pkg. 12) B0193161 37<br />

1.52 mm i.d., Yellow/Blue<br />

Tubing (pkg. 12) B0506058 37<br />

0.76 mm i.d., Black/Black<br />

Tubing (pkg. 12) B0507692 62<br />

1 mm i.d., White/White<br />

Resistant to organic solvents<br />

Preconcentration Columns<br />

1<br />

1<br />

1<br />

Components Part No. Each (€)<br />

C 18 Preconcentration Column B0504047 689<br />

PTFE column packed with silica-immobilized<br />

C 18 Material. (Pkg.10)<br />

XAD-8 Preconcentration Column B0504048 689<br />

PTFE column packed with XAD-8 Material. (Pkg.10)<br />

Cr Preconcentration Column B0509561 631<br />

Alumina column for speciation of<br />

Cr (III) and Cr (Vi). (Pkg.10)<br />

A<br />

3<br />

A<br />

3<br />

A<br />

9<br />

PTFE Tubing Assemblies<br />

3<br />

4<br />

5<br />

6<br />

In the PTFE tubing assemblies described<br />

below, the numbers in parentheses refer to<br />

the length of the tubing assembly and the<br />

number of flanged ends with screw fittings.<br />

Components Part No. Each (€)<br />

PTFE Tubing Assembly B0191059 29<br />

Carrier or reagent container to peristaltic<br />

pump tubing, 1 mm i.d. (700 mm x 1 flanged end)<br />

PTFE Tubing Assembly B0191058 19<br />

Manifold to manifold and to tubing adapter C,<br />

1 mm i.d. (110 mm x 2 flanged ends)<br />

PTFE Tubing Assembly B0501594 34<br />

Valve to preconcentration column,<br />

0.35 mm i.d. (60 mm x 2 flanged ends)<br />

PTFE Tubing Assembly B0501595 64<br />

3-dimensional reactor, 0.35 mm i.d.<br />

(two flanged ends)<br />

Tubing Adapters and Connectors<br />

7<br />

A<br />

C<br />

G<br />

II<br />

A<br />

5<br />

4<br />

1<br />

2<br />

8 C<br />

5<br />

G<br />

Components Part No. Each (€)<br />

Tubing Adapter A B0193342 12<br />

Connects thin (1 to 2 mm i.d.) peristaltic<br />

pump tubing with the PTFE tubing screw fittings<br />

Tubing Adapter C B0196850 38<br />

Connects to 3 mm waste tubing<br />

Tubing Adapter G B0501580 71<br />

For peristaltic pump tubing to merge<br />

chelate and sample streams<br />

Tubing Connector Type II B0196704 3<br />

Connects two PTFE tubing screw fittings<br />

4<br />

II<br />

C<br />

6<br />

28


Graphite Furnace<br />

Graphite Tubes and Supplies<br />

Trust Your Analysis to<br />

Genuine PerkinElmer Graphite<br />

Rely on PerkinElmer graphite<br />

for consistent analytical results.<br />

Every sample. Every day.<br />

We Start With an Exclusive Grade of Graphite<br />

The production of high-quality graphite<br />

components requires stringent quality control.<br />

Selection and careful control of raw materials are<br />

extremely important.<br />

The composition and the microstructure of the<br />

base graphite material determines the resistivity<br />

of the tube and its heating characteristics. To<br />

ensure high quality and consistency, a specific<br />

high-density base graphite material has been<br />

developed for use with PerkinElmer graphite<br />

furnace systems. This base graphite material is<br />

used exclusively for the manufacturing of<br />

PerkinElmer’s graphite components.<br />

Our Tubes Are Manufactured<br />

and Tested to the Highest<br />

Quality Specifications<br />

During manufacturing, a comprehensive<br />

quality testing program — including<br />

extensive mechanical, electrical,<br />

thermal, and analytical testing<br />

procedures — is strictly followed.<br />

Each lot of graphite tubes is tested to<br />

demanding specifications for lifetime,<br />

sensitivity, and precision.<br />

Extensive testing ensures that all graphite<br />

components shipped by PerkinElmer<br />

provide consistent lot-to-lot performance.<br />

Our Pyrolytic Coating Design<br />

is Critical to Achieving<br />

High Performance<br />

The specified thickness of pyrolytic coating<br />

applied to PerkinElmer graphite improves<br />

the total resistance of the graphite tube and<br />

the temperature distribution within the<br />

tube. Improper pyrolytic coating can<br />

shorten tube lifetime dramatically.<br />

The microstructure and density of the<br />

surface are important parameters for the<br />

atomization kinetics of analyte elements.<br />

Irreproducible surface qualities will cause<br />

changes in the optimal drying, pyrolysis<br />

and atomization temperatures, peak shape<br />

and characteristic mass. PerkinElmer’s<br />

coating specification and quality control<br />

ensure consistency from tube to tube.<br />

You Can Depend on<br />

Our Extensive Experience<br />

PerkinElmer has over three decades<br />

of experience in the design and<br />

development of graphite furnace<br />

systems and materials. Years of<br />

PerkinElmer development have<br />

yielded the best possible graphite<br />

for atomic absorption.<br />

Any other graphite has not been<br />

optimized for use with PerkinElmer<br />

instruments and may yield<br />

inaccurate analytical results.<br />

29


Graphite Furnace<br />

Graphite Tubes and Supplies<br />

Do Not Accept Imitations<br />

Graphite components offered by other companies<br />

often refer to the PerkinElmer part, implying that these<br />

components are made from the same material and provide<br />

equivalent performance. This is misleading, as these<br />

imitation components are not made from the same<br />

base graphite material, nor are they tested to the same<br />

demanding quality control specifications. The different<br />

base graphite material will alter the temperature<br />

calibration, the heating rates, and the performance<br />

characteristics.<br />

Rely on Genuine PerkinElmer Graphite<br />

Today’s analysts expect exceptional analytical performance<br />

from their graphite furnace atomic absorption spectrometers.<br />

That performance must be stable and reproducible from<br />

day to day with respect to sensitivity (characteristic mass),<br />

accuracy, and precision.<br />

The graphite tube, the heart of the graphite furnace, plays<br />

a vital role in the overall stability of an analysis. In order<br />

to assure stable analytical conditions from one atomization<br />

cycle to the next, and from graphite tube to graphite tube,<br />

all graphite parts – contacts, tubes, and platforms –<br />

must be under strict quality control by both the instrument<br />

manufacturer and the graphite manufacturer. PerkinElmer<br />

graphite components continue to set the industry standard<br />

for quality.<br />

The proper performance, maintenance, and serviceability<br />

of your graphite furnace system can be assured only<br />

through the use of genuine, high-quality PerkinElmer<br />

graphite components.<br />

How is High-Quality Graphite Manufactured?<br />

■ Select carefully chosen raw materials that are exclusive to PerkinElmer<br />

■ Mill and mix the components with precision<br />

■ Utilize the proper pressing techniques<br />

■ Employ the correct heat treatments at carefully selected times<br />

■ Purify materials at multiple times throughout the process<br />

■ Apply special coating technology for pyrolytic products<br />

■ Test and qualify graphite against rigorous PerkinElmer standards<br />

■ Machine patented PerkinElmer designs using specialized techniques<br />

30


Contact Cylinders<br />

The graphite contact cylinders used in the HGA ® Graphite<br />

Furnace are engineered for a precise fit so that variations<br />

in electrical contact – which might affect the analytical<br />

performance – are reduced to a minimum. The graphite<br />

contacts are shaped so that they completely encase the<br />

graphite tube. Thus, the graphite tube is located in a<br />

defined inert environment, which ensures uniform<br />

heating conditions and long tube lifetime.<br />

Contact Cylinders for HGA-500/400 Furnaces<br />

Includes left-hand Contact, right-hand Contact, Shield Ring.<br />

Description Part No. Each (€)<br />

5 sets B0180363 492<br />

Contact Cylinders for Zeeman HGA Furnaces<br />

Includes left-hand Contact, right-hand Contact.<br />

Description Part No. Each (€)<br />

1 set B0116823 130<br />

5 sets B0180361 617<br />

Contact Cylinders for<br />

HGA-900/850/800/700/600/300 Furnaces<br />

Includes left-hand Contact, right-hand Contact, Shield Ring.<br />

Description Part No. Each (€)<br />

1 set B0128495 107<br />

5 sets B3130086 506<br />

Contact Cylinders Removal Tool<br />

Description Part No. Each (€)<br />

For HGA-300/400/500/600/700/800 Furnaces B0098258 536<br />

For HGA-600 Zeeman Furnaces B0127431 472<br />

For AAnalyst 700 and HGA-850/900 B3121301 320<br />

Graphite Furnace Tubes and Supplies<br />

HGA Graphite Contact Cylinders, Tubes, and Supplies<br />

For Zeeman HGA Furnaces<br />

Part No. B0120242<br />

Graphite Tube Alignment Tools<br />

Description Part No. Each (€)<br />

For Non-Zeeman Furnaces B0080112 80<br />

For Zeeman HGA Furnaces B0120242 80<br />

L’vov Platforms<br />

The L’vov Platform is a small plate of solid pyrocoated<br />

graphite that is inserted into the graphite tube. It has a slight<br />

depression in the center which can accommodate up to 50 μL<br />

of solution. The function of the L’vov Platform is to isolate<br />

the sample from the tube walls to allow more reproducible<br />

atomization of the sample through indirect heating. The<br />

platform heats primarily by the radiation given off from the<br />

tube walls. Sample vaporization and atomization occur after<br />

the tube reaches a steady-state temperature.<br />

Use of the L’vov Platform provides:<br />

■ Vaporization into a higher temperature gas atmosphere<br />

producing more free atoms, which reduce interferences<br />

■<br />

For Non-Zeeman Furnaces<br />

Part No. B0080112<br />

Longer tube life because aggressive samples are only<br />

in contact with the solid pyrolytic graphite platform<br />

Description Part No. Each (€)<br />

5-pack B0137112 104<br />

20-pack B3001256 394<br />

50-pack B0109324 935<br />

100-pack N3110145 1765<br />

Graphite Furnace Tubes and Supplies Atomic Absorption<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

31


Atomic Absorption Graphite Furnace Tubes and Supplies<br />

Graphite Furnace Tubes and Supplies<br />

HGA Graphite Contact Cylinders, Tubes, and Supplies<br />

Matrix Modifiers for<br />

Graphite Furnace AA<br />

■<br />

■<br />

■<br />

High-purity compounds minimize<br />

the risk of contamination<br />

Optimum graphite furnace program<br />

can be used due to reduced<br />

analyte volatility<br />

Convenient, ready-to-use<br />

Modifier Concentration Volume (mL) Part No. Each (€)<br />

Mg(No 3 ) 2 1% Mg (as nitrate) 100 B0190634 71<br />

Pd 1% Pd (as nitrate) 50 B0190635 249<br />

NH 4 H 2 PO4 10% NH 4 H 2 PO4 100 N9303445 101<br />

Pyrocoated Graphite Tubes (Grooved)<br />

for use with L’vov Platforms<br />

Pyrocoated Graphite Tubes (Grooved)<br />

Internally grooved to accept L’vov Platforms.<br />

Description Part No. Each (€)<br />

5-pack B0137111 237<br />

20-pack B3001254 900<br />

50-pack B0109322 2131<br />

100-pack N3110146 4026<br />

Cross-section of the PerkinElmer HGA graphite tube<br />

with manually inserted L’vov platform.<br />

HGA Furnace Mirror<br />

Part No.<br />

Uncoated Graphite Tubes Part No. B0070699<br />

Each (€)<br />

B0080259 83<br />

Pyrocoated Graphite Tubes<br />

with Integrated Platforms<br />

Graphite tubes with integrated platforms are machined from<br />

one piece of graphite and are totally pyrocoated, providing<br />

exceptional tube-to-tube reproducibility.<br />

The spherically shaped platform<br />

accommodates up to 50 μL of sample.<br />

Pyrocoated Graphite Tubes with<br />

Integrated Platforms Part No. B3001262<br />

Graphite tubes with integrated platforms:<br />

■<br />

■<br />

■<br />

Provide STPF conditions for volatile and nonvolatile refractory<br />

elements due to the significantly higher heating rates of tube<br />

and platform, which can be used for all elements<br />

Offer an extra measure of convenience versus manually<br />

inserting a separate platform<br />

Provide longer life with many aggressive sample matrices,<br />

such as concentrated acids<br />

Cross-section of the PerkinElmer HGA graphite tube<br />

with integrated platform.<br />

Pyrocoated Graphite Tubes with Integrated Platforms<br />

Description Part No. Each (€)<br />

5-pack B3001262 317<br />

20-pack B3001264 1138<br />

100-pack N3110149 5400<br />

Pyrocoated Graphite Tubes*<br />

Description Part No. Each (€)<br />

5-pack B0105197 213<br />

10-pack B0135653 403<br />

20-pack B3000342 765<br />

50-pack B0091504 1808<br />

* Not compatible with L’vov Platforms.<br />

Uncoated Graphite Tubes*<br />

Description Part No. Each (€)<br />

50-pack B0070699 965<br />

* Not compatible with L’vov Platforms.<br />

32


Circulatory Cooling System<br />

HGA Circulatory Cooling System for HGA-800/850/900<br />

Voltage Part No. Each (€)<br />

115 V, 60 Hz B3001124 4323<br />

230 V, 50/60 Hz B3001123 4323<br />

Glycerol<br />

(85% for cooling systems), 1 L<br />

Quartz Windows<br />

The HGA Graphite Furnace Assembly is sealed at both ends<br />

with easily removable quartz windows. This closed-furnace<br />

design is a prerequisite for controlled and reproducible<br />

internal analytical conditions.<br />

Model Window Part No. Each (€)<br />

AAnalyst 700/HGA-850/900 Left- and Right-hand B0080850 109<br />

Model Window (small window) Part No. Each (€)<br />

Zeeman 5X00<br />

Zeeman 3030<br />

HGA-300/400/500<br />

HGA-600/700<br />

HGA-800<br />

Right-hand<br />

Right-hand<br />

Left- and Right-hand<br />

Right-hand<br />

Left-hand<br />

Graphite Furnace Tubes and Supplies<br />

HGA Graphite Cooling Systems and Quartz Windows<br />

B0066549 21<br />

Model Window (large window) Part No. Each (€)<br />

Zeeman 3030, 5X00<br />

HGA-600/700<br />

HGA-800<br />

1<br />

2<br />

3<br />

4<br />

5<br />

Left-hand<br />

Left-hand<br />

Right-hand<br />

Quartz Window Components<br />

Part No.<br />

Each (€)<br />

B3141064 29<br />

B0115576 43<br />

Components Part No. Each (€)<br />

O-Ring B0047209 2<br />

Gasket* B0071145 1<br />

Window B0066549 21<br />

Window B0115576 43<br />

Gasket** B0104342 2<br />

* Use B0147153 on the HGA-800<br />

** Use B0196825 on HGA-600s and HGA-700s installed after May 1990<br />

1<br />

2<br />

HGA Circulatory Cooling System<br />

Part No. B3001124<br />

3<br />

4<br />

5<br />

Graphite Furnace Tubes and Supplies Atomic Absorption<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

33


Atomic Absorption Graphite Furnace Tubes and Supplies<br />

Graphite Furnace Tubes and Supplies<br />

THGA Graphite Contact Cylinders, Tubes, and Supplies<br />

Contact Cylinders<br />

The graphite contact cylinders are engineered for a precise<br />

fit so that variations in electrical contact – which might<br />

affect the analytical performance – are reduced to a<br />

minimum. Contact cylinders with a modified injection<br />

port area help to minimize condensation and improve<br />

analytical performance with difficult matrices.<br />

Standard THGA Contact Cylinders<br />

Description Part No. Each (€)<br />

1 pair B0504035 174<br />

5 pairs B0504036 824<br />

Modified THGA Contact Cylinders<br />

For improved analytical performance with samples that<br />

have a high concentration of dissolved salts or matrices<br />

with a high boiling point with transversely heated<br />

graphite furnaces.<br />

Description Part No. Each (€)<br />

1 pair B3002103 187<br />

5 pairs B3002102 886<br />

Accessories and Spare Parts<br />

Description Part No. Each (€)<br />

O-Ring (behind contact cylinder, front and back) B0500748 1<br />

Contact Cylinder Removal Tools B3120405 402<br />

Graphite Tubes<br />

Standard THGA Graphite Tube<br />

PerkinElmer’s unique, transverselyheated<br />

graphite tube includes an<br />

integrated platform. The exceptionally<br />

uniform temperature distribution<br />

obtained with transverse heating<br />

significantly reduces or eliminates<br />

condensation of the sample matrix<br />

components and “memory” effects, and improves the<br />

atomization efficiency for refractory elements.<br />

Description Part No. Each (€)<br />

5-pack B3000641 600<br />

20-pack B0504033 2156<br />

100-pack N3110147 10200<br />

Standard THGA Graphite Tube with End Cap*<br />

■<br />

■<br />

For improved characteristic<br />

mass with volatile and<br />

medium refractory elements<br />

such as Ag, As, Cd, Co, Cr<br />

Cu, Pb, Se, and Tl, the THGA<br />

graphite tubes with end caps<br />

are recommended.<br />

Improved detection limits for volatile and medium<br />

refractory elements<br />

Faster drying for complex matrices due to enlarged<br />

dosing hole<br />

Description Part No. Each (€)<br />

5-pack B3000653 612<br />

20-pack B3000655 2200<br />

* Not recommended for refractory elements such as V or Ba.<br />

UltraClean THGA Graphite Tube<br />

Cross-section of the<br />

PerkinElmer THGA<br />

transversely-heated<br />

graphite tube with<br />

integrated platform<br />

and end cap<br />

For the lowest possible detection limits, residual contaminant<br />

levels may not be low enough to meet your requirements. For<br />

the most demanding analyses, PerkinElmer offers UltraClean<br />

THGA graphite tubes – delivering exceptionally low levels of<br />

contamination due to advanced high-temperature gas-phase<br />

cleaning procedures. UltraClean graphite tubes offer<br />

unmatched analytical advantages for special applications<br />

such as the determination of extremely low traces of Na,<br />

Ca, Fe, Cr, and Ni in ultra-clean reagents used in the<br />

semiconductor industry, and ultra-trace analyses of<br />

environmental, clinical, or food samples.<br />

Key Benefits<br />

■ UltraClean THGA graphite tubes have the lowest possible<br />

contamination levels due to extensive high-temperature<br />

gas-phase cleaning procedures<br />

■ UltraClean THGA graphite tubes are tested and specified<br />

for blank levels of Cr, Ni, V, Mo, Ti (


Matrix Modifiers for<br />

Graphite Furnace AA<br />

■<br />

■<br />

■<br />

High purity compounds minimize the risk of contamination<br />

Optimum graphite furnace program can be used due to<br />

reduced analyte volatility<br />

Convenient, ready-to-use<br />

Modifier Concentration Volume (mL) Part No. Each (€)<br />

Mg(No 3 ) 2 1% Mg (as nitrate) 100 B0190634 71<br />

Pd 1% Pd (as nitrate) 50 B0190635 249<br />

NH 4 H 2 PO4 10% NH 4 H 2 PO4 100 N9303445 101<br />

Spare Parts and Supplies<br />

Circulatory Cooling System for use<br />

with THGA Furnace Systems<br />

230 V, 50/60 Hz.<br />

Quartz Window for the THGA<br />

O-Ring<br />

For Furnace Window.<br />

Rinse Funnel for Fume Extraction System<br />

Used to aspirate water.<br />

Spare Graphite Tip for the Fume Extraction System<br />

(1 piece).<br />

Graphite Furnace Tubes and Supplies<br />

THGA Graphite Contact Cylinders, Tubes, and Supplies<br />

Part No.<br />

Each (€)<br />

B0198072 3890<br />

Part No.<br />

Part No.<br />

Each (€)<br />

B0198005 120<br />

Each (€)<br />

B0501236 13<br />

Part No.<br />

Each (€)<br />

B0508836 13<br />

Part No.<br />

Each (€)<br />

B0506722 24<br />

THGA Furnace Mirror<br />

Used to optimize drying temperatures<br />

and times.<br />

THGA Graphite Tube Pliers<br />

Part No.<br />

Each (€)<br />

B0851900 85<br />

Part No.<br />

Each (€)<br />

09907925 8<br />

Graphite Furnace Tubes and Supplies Atomic Absorption<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

35


Laboratory Products<br />

Filters, Regulators, and Supplies<br />

Atomic Absorption Laboratory Products<br />

Filters<br />

Balston ® Air Filter Assembly Type A-82<br />

Replacement Air Filter<br />

Specifically designed to<br />

remove water, oil, and dirt<br />

particles down to 0.6 microns<br />

in diameter from compressed<br />

air lines. It is recommended for<br />

use with oil-type compressors,<br />

and for removing moisture and<br />

dirt particles from air supplied<br />

by oil-less compressors.<br />

Wilkerson ® Air Dryer Filter<br />

Provides clean air for burner<br />

controls used with AA<br />

spectrometers. It removes<br />

entrained water, oil, and water<br />

aerosols, and solid particles<br />

from compressed air lines. The<br />

pressure regulator reduces the<br />

air pressure, which decreases<br />

the relative humidity of the<br />

air and prevents further<br />

condensation. The final filter removes aerosols and particles<br />

which are small enough to pass through the pre-filter. Oil,<br />

if present, is collected on the coalescing-type final filter and<br />

drips to the bottom of the bowl. The assembly consists of a<br />

shut-off valve, a pre-filter with automatic drain, a pressure<br />

reducing regulator with pressure gauge, a final filter, and a<br />

final filter indicator.<br />

Part No. Each (€)<br />

Max Inlet Pressure: 150 psig<br />

00470652 555<br />

Replacement Filters<br />

Part No.<br />

Each (€)<br />

N0580531 281<br />

Part No.<br />

Each (€)<br />

N0582251 42<br />

Replacements (Pre-filter) Part No. Each (€)<br />

Filter Elements 09923464 19<br />

Filter Bowls N9302199 25<br />

Replacements (Final Filter) Part No. Each (€)<br />

Filter Elements 09907120 47<br />

Filter Bowls N9302199 25<br />

Bowl O-ring Kit N9302197 45<br />

Balston 95A Acetylene<br />

Acetylene Replacement<br />

Filter Cartridge<br />

Parker Balston 73-099 AA Gas Purifier<br />

Includes a Balston Grade<br />

BQ filter cartridge to remove<br />

liquid and solid contaminants<br />

from the acetylene supply to<br />

99.99% at 0.01 micron.<br />

Max Working Pressure: 15 psig<br />

A wall-mounted system designed<br />

to purify the compressed air and<br />

acetylene gases used in atomic<br />

absorption. It consists of two<br />

independent filtration systems,<br />

one for compressed air and<br />

one for acetylene. The unit<br />

also has a flashback arrestor<br />

on the acetylene line and a<br />

pressure regulator on the<br />

compressed air line.<br />

The two-stage air filtration<br />

assembly consists of a Balston Grade DX coalescing filter and<br />

a Balston Grade BX coalescing filter. Together these filters<br />

remove oil, water, and particulate contamination (99.99% at<br />

0.01 micron) from the compressed air supply.<br />

Replacement Cartridges<br />

Part No.<br />

Each (€)<br />

N9301399 312<br />

Part No.<br />

Each (€)<br />

N9301714 12<br />

Part No.<br />

Each (€)<br />

N9301398 1008<br />

1st Air Filter Part No. Each (€)<br />

Replacement Cartridges N9301710 18<br />

Replacement Seal Sets N9301712 17<br />

2nd Air Filter Part No. Each (€)<br />

Replacement Cartridges N9301711 18<br />

Replacement Seal Sets N9301712 17<br />

Acetylene Filter Part No. Each (€)<br />

Replacement Cartridges N9301714 12<br />

Replacement Seal Sets N9301715 10<br />

36


Laboratory Products<br />

Filters, Regulators, and Supplies<br />

Flash Arrestor<br />

Instrument Filters<br />

Filter Cartridge for Fume Extraction Separator Trap<br />

(pkg. 50)<br />

Part No. Each (€)<br />

B0509065 37<br />

Matheson Flashback Arrestor<br />

Because acetylene is an extremely unstable gas, users<br />

can experience flashbacks at the instrument burner head.<br />

The flash arrestor prevents these potentially dangerous<br />

flashbacks from reaching the regulator or cylinder.<br />

Acetylene Max Operating Pressure: 15 psig<br />

Positive shut-off of gas – checks the reverse flow under all<br />

conditions. Also stops gas supply when a flashback occurs.<br />

Hose Assemblies<br />

Acetylene, Red<br />

Part No. 00570559<br />

Hose Assemblies<br />

Part No.<br />

Air/Argon, Black<br />

Part No. 00570567<br />

Each (€)<br />

N9300068 312<br />

Hose assemblies for connecting fuel, air, and nitrous oxide<br />

from supply to instrument.<br />

Description Part No. Each (€)<br />

Acetylene, red, 3.7 m (12 ft.) long 00570559 80<br />

Air/Argon, black, 3.7 m (12 ft.) long 00570567 80<br />

Nitrous Oxide, blue, 3.7 m (12 ft.) long 00470258 116<br />

Instrument Filters<br />

Description Part No. Each (€)<br />

Filter for AA 100/300 09995097 21<br />

Filter for AA 200/400/600/700/800 B0501696 21<br />

Filter for AA 600/700/800 (80x80) B0502706 15<br />

SIMAA 6100/6000<br />

Rear filter. (pkg. 1)<br />

Square Filter Pads<br />

4100 ZL/4110 ZL, side and<br />

back filters. (pkg. 1)<br />

MiniDispenser<br />

Aqueous and organic solutions as well as acids (including HF)<br />

can be easily dispensed without the risk of sample contamination<br />

when using the high-precision MiniDispenser.<br />

Bottle Holder PP-250<br />

MiniDispenser<br />

Replacement Valve Kit<br />

For replacing MiniDispenser valves.<br />

Part No.<br />

Used to stabilize 250 mL<br />

plastic bottles such as supplied<br />

by Suprapur ® and<br />

Optima chemicals.<br />

Preassembled and tested.<br />

Includes GL45, S40, and<br />

38-430 bottle adapters.<br />

Each (€)<br />

B0502706 15<br />

Part No.<br />

Each (€)<br />

B0501252 3<br />

Part No.<br />

Each (€)<br />

B0511806 59<br />

Part No.<br />

Each (€)<br />

B0511778 201<br />

Part No.<br />

Each (€)<br />

B0511779 130<br />

Laboratory Products Atomic Absorption<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

37


Laboratory Products<br />

Filters, Regulators, and Supplies<br />

Regulators<br />

Acetylene Regulator<br />

Argon/Nitrogen Regulator<br />

Atomic Absorption Laboratory Products<br />

Air Regulator<br />

Venting System<br />

Includes an adapter<br />

so that the pressure<br />

regulator can be<br />

connected to cylinders<br />

requiring either CGA 300<br />

or CGA 510 fittings and<br />

a connector for attaching<br />

the fuel hose assembly<br />

supplied with the<br />

instrument. Includes<br />

hose assembly.<br />

Max Inlet Pressure:<br />

400 psig<br />

Part No.<br />

Regulator to cylinder<br />

CGA no. 590. Includes<br />

hose assembly.<br />

Max Inlet Pressure:<br />

3000 psig<br />

Venting System<br />

Each (€)<br />

03030106 446<br />

Part No.<br />

Each (€)<br />

03030264 446<br />

A venting system is<br />

required to remove fumes<br />

and vapors from the burner<br />

compartment of atomic<br />

absorption instruments.<br />

Includes exhaust hood,<br />

adapter, and blower.<br />

Note: Does not include ducting.<br />

PerkinElmer Service Engineers are<br />

not permitted to install this unit.<br />

Description Part No. Each (€)<br />

Blower and Vent Assembly 03030406 1218<br />

Exhaust Hood 03031910 236<br />

Nitrous Oxide Regulator<br />

Can be used with Argon<br />

or Nitrogen and has<br />

a CGA 580 fitting. A<br />

color-coded hose with<br />

1/4-inch SWAGELOK ®<br />

fittings is also included.<br />

Max Inlet Pressure:<br />

3000 psig<br />

Part No.<br />

Each (€)<br />

03030284 446<br />

For use with gas<br />

cylinders with a CGA 326<br />

connection. Provides<br />

pressure control from<br />

350-520 kPA (50-75 psig)<br />

and contains an integral<br />

thermostatted heater to<br />

prevent freezing of<br />

the regulator diaphragm.<br />

A color-coded hose with<br />

suitable connectors at<br />

each end is supplied<br />

with the regulators to<br />

provide connection to the<br />

instrument gas controls.<br />

Part No.<br />

Each (€)<br />

03030204 848<br />

38


Lamps for Atomic Absorption<br />

Lumina Hollow Cathode Lamps<br />

Genuine PerkinElmer<br />

Hollow Cathode Lamps<br />

for Atomic Absorption<br />

PerkinElmer’s expertise in the design and<br />

manufacture of light sources for atomic<br />

absorption spectrometers traces back to<br />

our original hollow cathode lamps, developed<br />

nearly 40 years ago.<br />

PerkinElmer manufactures a full range of singleelement<br />

and multi-element hollow cathode lamps<br />

and high-intensity electrodeless discharge lamps for<br />

those elements for which they are more effective.<br />

Every genuine PerkinElmer Lumina lamp is designed<br />

for use with, and tested on, our spectrometers to assure<br />

compatibility and the highest performance. To prolong<br />

the life of a Lumina hollow cathode lamp (HCL), we<br />

produce lamps with larger internal volume so that<br />

a greater supply of fill gas at optimum pressure is<br />

available. The larger the lamp, the greater the inert<br />

gas volume — and the longer the lamp lifetime.<br />

PerkinElmer offers a wide range of single-element and<br />

multi-element HCLs, which are ideal for determining<br />

most elements by atomic absorption spectroscopy.<br />

For the Widest Selection of Elements<br />

The basic components of a hollow cathode lamp (HCL) are a sealed glass<br />

cylinder filled with an inert gas (argon or neon), an anode, a cathode, and<br />

either glass or quartz end window. The cathode is a hollow cylinder of<br />

the element whose spectrum is to be produced, or in some cases, an alloy<br />

or carefully selected mixture of metals which do not spectrally interfere.<br />

Hollow cathode lamps emit light by the following process: The fill gas is<br />

ionized when an electrical potential is applied between the anode and<br />

the cathode. The positively charged ions collide with the negatively<br />

charged cathode and dislodge individual metal atoms in a process known<br />

as “sputtering.” These “sputtered” metal atoms are excited through<br />

impact with fill gas ions, and light of the specific wavelengths for that<br />

element is emitted when the atom “decays” from the excited state back<br />

to the more stable state.<br />

PerkinElmer Exclusive 6/24 WARRANTY*<br />

Lumina Hollow Cathode Lamps<br />

1. We warrant that during the first six months or after 5,000 milliampere-hours of operation,<br />

whichever comes first, from initial date of shipment, the lamps will meet or exceed the<br />

intensity and absorption specifications to which all new lamps are tested.<br />

2. All our hollow cathode lamps are warranted to light and emit the spectra of the element<br />

indicated for two years or 5,000 milliampere-hours of operation from the date of the<br />

shipment, whichever comes first.<br />

3. If any lamp fails before the expiration of the warranty period, it will be replaced free of charge.<br />

* The lamp warranty is void for lamps which sustain physical damage or are operated at power<br />

levels substantially above or below the power level recommended on the lamp label. The lamp<br />

warranty may vary in different countries.<br />

Features and Benefits<br />

■ Long Life: PerkinElmer’s larger ■ Quality: Carefully selected<br />

lamp volume results in longer materials used in the<br />

lamp lifetime<br />

manufacturing of our lamps<br />

■ Automation: PerkinElmer coded avoid spectral interference<br />

lamps allow automatic setup ■ Design: Our design provides you<br />

■ Easy Installation: It’s as simple with the low detection limits<br />

as sliding the lamp into the needed for your most difficult<br />

instrument’s lamp bracket<br />

determinations<br />

or turret<br />

■ Selection: PerkinElmer offers<br />

■ Timers: Each Lumina<br />

a wide selection of single-element<br />

hollow cathode lamp includes and multi-element lamps<br />

a milliampere-hour timer in its ■ Easy To Order: It’s easy to find<br />

base to monitor lamp usage the right lamp for your analytical<br />

■ Complete Compatibility: needs – simply use the selection<br />

Lumina hollow cathode lamps charts on page 40<br />

can be used with PerkinElmer’s ■ Warranty: The performance of<br />

entire range of atomic absorption every PerkinElmer lamp is<br />

spectrometers<br />

fully warranted<br />

■ Testing: Every lamp is thoroughly<br />

tested before leaving the factory<br />

39


Lamps for Atomic Absorption<br />

Lumina Hollow Cathode Lamps<br />

Lumina Lamps and Lamps with Adapters<br />

Atomic Absorption Lamps for Atomic Absorption<br />

Lumina coded hollow cathode lamps are available in two<br />

series: with and without an Intensitron adapter cable.<br />

Series N30501XX and N30502XX Lumina lamps<br />

do not include an Intensitron adapter cable and are<br />

designed to be used with PerkinElmer’s AAnalyst TM<br />

series of instruments.<br />

Series N30503XX and N30504XX Lumina lamps<br />

include an adapter cable that allows the lamps to be<br />

recognized by the following instruments: SIMAA TM<br />

6100/6000, 5100 (PC), 4110 ZL, 4100, 4100 ZL, 3300,<br />

2100, and 1100(B).<br />

Lumina hollow cathode lamps may also be used with<br />

all earlier AA spectrometers that do not have automatic<br />

code reading capability by using an appropriate<br />

adapter cable (refer to Adapter Cable on page 44).<br />

Lumina Lamp<br />

Lumina Plus Intensitron ®<br />

Element Element Lamp Adapter<br />

Name Symbol Part No. Each (€) Part No. Each (€)<br />

Aluminum Al* N3050103 483 N3050303 573<br />

Antimony Sb N3050170 573 N3050370 700<br />

Arsenic As N3050105 700 N3050305 828<br />

Barium Ba* N3050109 611 N3050309 738<br />

Beryllium Be* N3050110 802 N3050310 930<br />

Bismuth Bi N3050111 573 N3050311 675<br />

Boron B* N3050108 636 N3050308 764<br />

Cadmium Cd N3050115 547 N3050315 675<br />

Calcium** Ca N3050114 509 N3050314 636<br />

Chromium Cr N3050119 483 N3050319 611<br />

Cobalt Co N3050118 420 N3050318 547<br />

Copper*** Cu N3050121 420 N3050321 509<br />

Dysprosium Dy* N3050122 483 N3050322 663<br />

Erbium Er* N3050123 483 N3050323 663<br />

Europium Eu* N3050124 483 N3050324 611<br />

Gadolinium Gd* N3050129 483 N3050329 611<br />

Gallium Ga N3050128 509 N3050328 611<br />

Germanium Ge* N3050130 573 N3050330 700<br />

Gold Au N3050107 573 N3050307 700<br />

Hafnium Hf* N3050133 509 N3050333 663<br />

Holmium Ho* N3050135 599 N3050335 663<br />

Indium In N3050137 547 N3050337 636<br />

Iridium lr N3050138 802 N3050338 930<br />

Iron Fe N3050126 420 N3050326 509<br />

Lanthanum La* N3050141 636 N3050341 663<br />

Lead Pb N3050157 611 N3050357 738<br />

Lithium Li N3050142 509 N3050342 636<br />

Magnesium** Mg N3050144 483 N3050344 611<br />

Manganese Mn N3050145 509 N3050345 636<br />

Mercury Hg N3050134 547 N3050334 675<br />

Molybdenum Mo N3050146 483 N3050346 573<br />

Neodymium Nd* N3050150 483 N3050350 663<br />

Nickel Ni N3050152 420 N3050352 509<br />

Niobium Nb* N3050149 483 N3050349 573<br />

Palladium Pd N3050158 611 N3050358 738<br />

* This element requires a nitrous oxide-acetylene flame.<br />

** To measure secondary lines below 230 nm, choose the Ca/Mg/Zn lamp<br />

with quartz window.<br />

*** To measure secondary lines below 230 nm, choose the Cu/Fe/Mn/Zn lamp<br />

with quartz window.<br />

40


Lamps for Atomic Absorption<br />

Lumina Hollow Cathode Lamps<br />

Lumina Lamp<br />

Lumina Plus Intensitron ®<br />

Element Element Lamp Adapter<br />

Name Symbol Part No. Each (€) Part No. Each (€)<br />

Phosphorus P* N3050155 738 N3050355 866<br />

Platinum Pt N3050162 675 N3050362 802<br />

Potassium K N3050139 509 N3050339 611<br />

Praseodymium Pr* N3050161 599 N3050361 663<br />

Rhenium Re* N3050165 483 N3050365 759<br />

Rhodium Rh N3050166 675 N3050366 802<br />

Ruthenium Ru N3050168 738 N3050368 866<br />

Samarium Sm* N3050174 490 N3050374 663<br />

Scandium Sc* N3050171 573 N3050371 700<br />

Selenium Se N3050172 611 N3050372 738<br />

Silicon Si* N3050173 547 N3050373 675<br />

Silver Ag N3050102 483 N3050302 573<br />

Sodium Na N3050148 547 N3050348 675<br />

Strontium Sr N3050176 547 N3050376 675<br />

Tantalum Ta* N3050177 483 N3050377 611<br />

Tellurium Te N3050180 611 N3050380 738<br />

Terbium Tb* N3050178 547 N3050378 663<br />

Thallium Tl N3050183 547 N3050383 675<br />

Thulium Tm* N3050184 636 N3050384 764<br />

Tin Sn N3050175 547 N3050375 675<br />

Titanium Ti* N3050182 420 N3050382 547<br />

Tungsten W* N3050187 445 N3050387 547<br />

Vanadium V* N3050186 445 N3050386 573<br />

Ytterbium Yb* N3050190 509 N3050390 663<br />

Yttrium Y* N3050189 483 N3050389 611<br />

Zinc Zn N3050191 573 N3050391 700<br />

Zirconium Zr* N3050192 445 N3050392 573<br />

*This element requires a nitrous oxide-acetylene flame.<br />

Lamps for Atomic Absorption Atomic Absorption<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

41


Lamps for Atomic Absorption<br />

Lumina Hollow Cathode Lamps<br />

Lumina Multi-Element Hollow Cathode Lamps<br />

Atomic Absorption Lamps for Atomic Absorption<br />

Two-Element Lamps<br />

Lumina Lamp<br />

Lumina Lamp<br />

Lumina Plus Intensitron ®<br />

Lumina<br />

Plus Intensitron<br />

Element Element Lamp Adapter<br />

Element Element Lamp Adapter<br />

Name Symbol Part No. Each (€) Part No. Each (€) Name Symbol Part No. Each (€) Part No. Each (€)<br />

Ag-Au N3050201 509 N3050401 614 Ag-Cr-Cu-Fe-Ni N3050213 611 N3050413 802<br />

Silver Ag<br />

Silver Ag<br />

Gold Au<br />

Chromium Cr<br />

Ca-Mg* N3050202 611 N3050402 738 Copper Cu<br />

Calcium Ca<br />

Iron Fe<br />

Magnesium Mg<br />

Nickel Ni<br />

Ca-Zn N3050203 636 N3050403 764 Co-Cr-Cu-Mn-Ni N3050214 611 N3050414 738<br />

Calcium Ca<br />

Cobalt Co<br />

Zinc Zn<br />

Chromium Cr<br />

K-Na N3050204 611 N3050404 700 Copper Cu<br />

Potassium K<br />

Manganese Mn<br />

Sodium Na<br />

Nickel Ni<br />

Pt-Ru N3050205 802 N3050405 930 Co-Cu-Fe-Mn-Mo N3050215 636 N3050415 764<br />

Platinum Pt<br />

Cobalt Co<br />

Ruthenium Ru<br />

Copper Cu<br />

Sn-Te N3050206 611 N3050406 663 Iron Fe<br />

Tin Sn<br />

Manganese Mn<br />

Tellurium Te<br />

Molybdenum Mo<br />

Three-Element Lamps<br />

Al † -Ca-Mg* N3050207 611 N3050407 738<br />

Aluminum Al<br />

Calcium Ca<br />

Magnesium Mg<br />

Ca-Mg-Zn N3050208 675 N3050408 802<br />

Calcium Ca<br />

Magnesium Mg<br />

Zinc Zn<br />

Cu-Fe-Ni N3050209 611 N3050409 738<br />

Copper Cu<br />

Iron Fe<br />

Nickel Ni<br />

Four-Element Lamps<br />

Ag-Cr-Cu-Ni N3050210 636 N3050410 802<br />

Silver Ag<br />

Chromium Cr<br />

Copper Cu<br />

Nickel Ni<br />

Al-Cu-Fe-Ti † N3050211 547 N3050411 675<br />

Aluminum Al<br />

Copper Cu<br />

Iron Fe<br />

Titanium Ti<br />

Cu-Fe-Mn-Zn N3050212 611 N3050412 738<br />

Copper Cu<br />

Iron Fe<br />

Manganese Mn<br />

Zinc Zn<br />

Five-Element Lamps<br />

Six-Element Lamps<br />

Ag-Al † -Cr-Cu-Fe-Mg N3050216 611 N3050416 738<br />

Silver Ag<br />

Alumiunum Al<br />

Chromium Cr<br />

Copper Cu<br />

Iron Fe<br />

Magnesium Mg<br />

Co-Cr-Cu-Fe-Mn-Ni N3050217 611 N3050417 738<br />

Cobalt Co<br />

Chromium Cr<br />

Copper Cu<br />

Iron Fe<br />

Manganese Mn<br />

Nickel Ni<br />

Seven-Element Lamps<br />

Al*-Ca-Cu-Fe-Mg-Si † -Zn N3050218 611 N3050418 738<br />

Aluminum Al<br />

Calcium Ca<br />

Copper Cu<br />

Iron Fe<br />

Magnesium Mg<br />

Silicon Si<br />

Zinc Zn<br />

* To measure secondary lines below 230 nm, choose the Ca/Mg/Zn lamp with<br />

quartz window or the Ag, Al, Cr, Cu, Fe, Mg, or Al, Ca, Cu, Fe, Mg, Si, Zn<br />

lamps with quartz windows.<br />

†<br />

This element requires a Nitrous Oxide-Acetylene flame.<br />

42


Lamps for Atomic Absorption<br />

Lumina Hollow Cathode Lamp Coded Adapters<br />

Coded Lumina Adapters<br />

Element<br />

Element<br />

Symbols Part No. Each (€) Symbols Part No. Each (€)<br />

Ag N3050702 74 Re N3050765 74<br />

Al N3050703 74 Rh N3050766 74<br />

As N3050705 74 Ru N3050768 74<br />

Au N3050707 74 Sb N3050770 74<br />

B N3050708 74 Sc N3050771 74<br />

Ba N3050709 74 Se N3050772 74<br />

Be N3050710 74 Si N3050773 74<br />

Bi N3050711 74 Sn N3050775 74<br />

Ca N3050714 74 Sr N3050776 74<br />

Cd N3050715 74 Ta N3050777 74<br />

Co N3050718 74 Tb N3050778 74<br />

Cr N3050719 74 Te N3050780 74<br />

Cu N3050721 74 Ti N3050782 74<br />

Dy N3050722 74 Tl N3050783 74<br />

Er N3050723 74 V N3050786 74<br />

Fe N3050726 74 W N3050787 74<br />

Ga N3050728 74 Y N3050789 74<br />

Gd N3050729 74 Zn N3050791 74<br />

Ge N3050730 74 Zr N3050792 74<br />

Hg N3050734 74 Ag-Au N3050801 74<br />

Ho N3050735 74 Ca-Mg N3050802 74<br />

In N3050737 74 Ca-Zn N3050803 74<br />

Ir N3050738 74 K-Na N3050804 74<br />

K N3050739 74 Pt-Ru N3050805 74<br />

La N3050741 74 Sn-Te N3050806 74<br />

Li N3050742 74 Al-Ca-Mg N3050807 74<br />

Mg N3050744 74 Ca-Mag-Zn N3050808 74<br />

Mn N3050745 74 Cu-Fe-Ni N3050809 74<br />

Mo N3050746 74 Ag-Cr-Cu-Ni N3050810 74<br />

Na N3050748 74 Al-Cu-Fe-Ti N3050811 74<br />

Nb N3050749 74 Cu-Fe-Mn-Zn N3050812 74<br />

Nd N3050750 74 Ag-Cr-Cu-Fe-Ni N3050813 74<br />

Ni N3050752 74 Co-Cr-Cu-Mn-Ni N3050814 74<br />

P N3050755 74 Co-Cu-Fe-Mn-Mo N3050815 74<br />

Pb N3050757 74 Ag-Al-Cr-Cu-Fe-Mg N3050816 74<br />

Pd N3050758 74 Co-Cr-Cu-Fe-Mn-Ni N3050817 74<br />

Pr N3050761 74 Al-Ca-Cu-Fe-Mg-Si-Zn N3050818 74<br />

Pt N3050762 74<br />

Lamp Adapters<br />

These adapters allow Lumina HCLs to be<br />

used on PerkinElmer’s wide range of atomic<br />

absorption spectrometers.<br />

Lumina Lamp with Intensitron Adapter Cable for use with<br />

Models SIMAA 6100/6000, 5100 (PC), 4110 ZL, 4100,<br />

4100 ZL, 3300, 2100, and 1100(B).<br />

Lamps for Atomic Absorption Atomic Absorption<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

43


Lamps for Atomic Absorption<br />

Non-Coded Hollow Cathode Lamp Adapters<br />

Lamp Plug Adapters<br />

Atomic Absorption Lamps for Atomic Absorption<br />

Coded Intensitron ® Lamp Plug Adapter<br />

Allows coded Intensitron HCLs (N06612XX series, 12 pin)<br />

to be used with PerkinElmer atomic absorption<br />

instruments with non-coded lamp<br />

connectors (9 pin).<br />

Part No. Each (€)<br />

N0660123 147<br />

Lumina Lamp Plug Adapter<br />

Allows Lumina HCLs (N305XXXX series, 4 pin)<br />

to be used with PerkinElmer atomic absorption<br />

instruments with non-coded lamp<br />

connectors (9 pin).<br />

Part No. Each (€)<br />

N3050198 41<br />

Non-Coded Intensitron Lamp Plug Adapter<br />

Allows non-coded Intensitron hollow cathode lamps<br />

(030360XX series, 9 pin) to be used with the Models 5100<br />

(PC), 3300, and 4100ZL (12 pin).<br />

Part No. Each (€)<br />

Non-Coded Intensitron Lamp Plug Adapter<br />

Allows non-coded Intensitron lamps (03036XXX<br />

series, 9 pin) to be used with AAnalyst<br />

instruments (4 pin).<br />

Part No. Each (€)<br />

N3050197 41<br />

Non-Coded Intensitron Lamp Plug Adapter<br />

N0660122 147<br />

Allows non-coded Intensitron HCLs (030360XX<br />

series, 9 pin) to be used with Models 4100, 4100 ZL,<br />

2100, and 1100(B) (12 pin). Not for use<br />

on SIMAA 6100/6000.<br />

Part No. Each (€)<br />

B0156094 236<br />

Universal Coded Intensitron Lamp Plug Adapter<br />

Allows coded lamps (N06612XX series, 12 pin) to be<br />

used with AAnalyst instruments (4 pin); however, an<br />

AAnalyst spectrometer does not recognize<br />

their coding.<br />

Part No. Each (€)<br />

N3050196 45<br />

44


Lamps for Atomic Absorption<br />

Supplies<br />

Background Corrector Sources<br />

For Instrument<br />

Source<br />

Models Type Part No. Each (€)<br />

AAnalyst 100/300, Deuterium N0370119 765<br />

3300, 3110, 3100<br />

AAnalyst 200/400 Deuterium B3150169 304<br />

AAnalyst 700/800 Deuterium B0148615 765<br />

2280, 2380, 280, 380 Deuterium 00570194 695<br />

3030(B)* Deuterium 00570194 695<br />

3030(B)** Deuterium B0127014 318<br />

4000, 5000, 5100, 5100 (PC), Tungsten-halide C0550500 69<br />

Zeeman/5000, Zeeman/5100 (PC)<br />

4100, 2100, 1100(B) Deuterium B0148615 765<br />

For all instruments except the AAnalyst series, we recommend that an<br />

authorized PerkinElmer Service Engineer install your Background Corrector<br />

Source. Installation is not included in the price.<br />

* For instruments with 10-digit serial numbers<br />

** For instruments with 4-digit serial numbers<br />

Supplies<br />

SIMAA 6100/6000 Quick-Change<br />

Lamp Mount Assembly<br />

Small Diameter Lamp Adapter Kit<br />

Permits the use of hollow cathode lamps of smaller diameter<br />

than the PerkinElmer 2 in. diameter hollow cathode lamps<br />

used in PerkinElmer atomic absorption spectrometers.<br />

Red Filter<br />

Part No.<br />

Part No.<br />

Linearizes working curves for potassium, lithium, rubidium,<br />

and cesium. Recommended for Rb and Cs determinations by<br />

flame emission. Passes only wavelengths longer than 650 nm.<br />

Many PerkinElmer atomic absorption spectrometers are<br />

equipped with a filter holder for easy use.<br />

Part No.<br />

Each (€)<br />

B3000656 166<br />

Each (€)<br />

N3051050 152<br />

Each (€)<br />

02901518 70<br />

Background Corrector Source<br />

(For AAnalyst 100/300 and models<br />

3300, 3110, 3100)<br />

Part No. N0370119<br />

Small Diameter Lamp Adapter Kit Part No. N3051050<br />

Lamps for Atomic Absorption Atomic Absorption<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

45


Lamps for Atomic Absorption<br />

System 2 EDL Lamps<br />

System 2 Electrodeless<br />

Discharge Lamps<br />

Maximum Intensity and Long Life<br />

While hollow cathode lamps are an ideal source<br />

for determining most elements by atomic<br />

absorption, for volatile elements we recommend<br />

the use of electrodeless discharge lamps.<br />

EDLs provide greater light output and longer life than<br />

corresponding HCLs. For certain elements, such as Arsenic<br />

and Selenium, EDLs will also provide improved sensitivity<br />

and lower detection limits. System 2 electrodeless discharge<br />

lamps provide the optimized spectral output needed to get<br />

the maximum performance from PerkinElmer atomic<br />

absorption spectrometers.<br />

PerkinElmer’s System 2 EDLs<br />

Consist of two major components: a dual-channel power supply with<br />

matched dual RF driver assemblies, which allows simultaneous,<br />

independent operation of two EDLs, and the interchangeable lamp<br />

sleeves. The lamp sleeve contains the pre-aligned bulb for the element<br />

of interest. The sleeve has the same exterior dimensions as the<br />

PerkinElmer HCLs, allowing System 2 EDLs to be used in the same<br />

lamp mounts and turrets.<br />

System 2 EDLs are as easy-to-use as an HCL. Just install the lamp, turn it<br />

on, and set the current. Changing lamps requires only seconds because<br />

the pre-aligned bulbs require no additional adjustment.<br />

System 2 EDLs include two coded adapter plugs that allow automatic<br />

spectrometer set-up for those PerkinElmer atomic absorption<br />

spectrometers with automatic lamp code reading capabilities.<br />

To ensure operator safety, a built-in interlock prevents lamp operation if<br />

the lamp is not properly installed.<br />

The PerkinElmer Exclusive WARRANTY*<br />

System 2 Electrodeless Discharge Lamps<br />

1. We warrant that during the first six months or after 500 hours of operation, whichever comes<br />

first, from initial date of shipment, the lamps will meet or exceed the intensity and absorption<br />

specifications to which all new lamps are tested.<br />

2. All our Electrodeless Discharge Lamps are warranted to light and emit the spectra of the<br />

element indicated for two years or 1,000 hours of operation from the date of the shipment,<br />

whichever comes first.<br />

3. If any lamp fails before the expiration of the warranty period, it will be replaced free of charge.<br />

* The lamp warranty is void for lamps that sustain physical damage or are operated at power<br />

levels substantially above or below the power level recommended on the lamp label.<br />

The lamp warranty may vary in different countries.<br />

Electrodeless Discharge Lamps For Greater Brightness<br />

EDLs are typically much brighter and, in some cases,<br />

provide better sensitivity than comparable HCLs. EDLs are<br />

preferred for certain volatile elements. They offer better<br />

precision and lower detection limits for analyses that are<br />

“noisy” due to weak hollow cathode emission. PerkinElmer<br />

System 2 EDLs consist of the element or a salt of the<br />

element sealed in a quartz bulb containing an inert<br />

gas atmosphere. When an RF field of sufficient power is<br />

applied, the inert gas is ionized and the coupled energy<br />

vaporizes the element and excites the atoms inside the bulb,<br />

resulting in the emission of the characteristic spectrum.<br />

Features and Benefits<br />

■ Brightness: EDLs are much brighter and, in some cases, provide better<br />

sensitivity than comparable hollow cathode lamps<br />

■ Precision: EDLs offer lower detection limits and are preferred for<br />

analyses that are “noisy” due to weak hollow cathode emission<br />

■ Long Life: System 2 EDLs are long-lived for exceptional<br />

cost-effectiveness<br />

■ Automation: PerkinElmer coded lamps allow automatic set-up on<br />

systems with automated turret<br />

■ Quality: Carefully selected materials used in the manufacturing of our<br />

lamps avoid spectral interference<br />

■ Testing: Every lamp is thoroughly tested<br />

■ Design: Our design provides you with the low detection limits needed<br />

for your most difficult determinations<br />

■ Warranty: The performance of every PerkinElmer lamp is fully warranted*<br />

46


Lamps for Atomic Absorption<br />

System 2 EDL Lamps<br />

System 2 EDL Lamps and Adapters<br />

AAnalyst<br />

System 2 Coded Intensitron ®<br />

Element Element EDL Adapter<br />

Symbol Name Part No. Each (€) Part No. Each (€)<br />

As Arsenic N3050605 587 N3050860 45<br />

Bi Bismuth N3050611 587 N3050861 45<br />

Cd Cadmium N3050615 587 N3050862 45<br />

Cs Cesium N3050620 587 N3050863 45<br />

Ge* Germanium N3050630 587 N3050864 44<br />

Hg Mercury N3050634 587 N3050865 45<br />

P* Phosphorus N3050655 587 N3050866 45<br />

Pb Lead N3050657 547 N3050867 45<br />

Rb Rubidium N3050664 587 N3050868 45<br />

Sb Antimony N3050670 587 N3050869 45<br />

Se Selenium N3050672 587 N3050870 45<br />

Sn Tin N3050675 587 N3050871 45<br />

Te Tellurium N3050680 587 N3050872 44<br />

Tl Thallium N3050683 587 N3050873 45<br />

Zn Zinc N3050691 587 N3050874 45<br />

* This element requires a Nitrous Oxide-Acetylene flame<br />

Note: System 2 EDLs come with two coding plugs: a coding plug compatible<br />

with the AAnalyst series of instruments and a coding plug compatible with<br />

earlier instruments having coding capability; for example, the Models SIMAA<br />

6100/6000, 5100 (PC), 4110 ZL, 4100 ZL, 4100, 3300, 2100, and 1100(B).<br />

EDL lamps are compatible with all PerkinElmer atomic absorption<br />

spectrometers except the Models 103, 107, 290, 290B, and 280.<br />

System 2 Electrodeless Discharge Lamps<br />

The PerkinElmer Exclusive WARRANTY*<br />

1. We warrant that during the first six months or after 500 hours of operation, whichever comes first, from initial date of shipment, the lamps<br />

will meet or exceed the intensity and absorption specifications to which all new lamps are tested.<br />

2. All our Electrodeless Discharge Lamps are warranted to light and emit the spectra of the element indicated for two years or 1,000 hours<br />

of operation from the initial date of shipment, whichever comes first.<br />

3. If any lamp fails before the expiration of the warranty period, it will be replaced free of charge.<br />

* The lamp warranty is void for lamps that sustain physical damage or are operated at power levels substantially above or below the power level<br />

recommended on the lamp label. The lamp warranty may vary in different countries.<br />

Lamps for Atomic Absorption Atomic Absorption<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

47


Lamps for Atomic Absorption<br />

System 2 EDL Lamp Supplies and Accessories<br />

EDL Accessories<br />

Atomic Absorption Lamps for Atomic Absorption<br />

EDL Driver Assembly<br />

Part No. 03030997<br />

System 2 EDL Power Supply<br />

Part No. 03030952<br />

Driver Assembly Adapter Cable<br />

Allows System 2 EDL drivers<br />

(03030793 and 03030997) to be<br />

used on an AAnalyst 200/400.<br />

Extension Cable<br />

Increases length of cable on the<br />

AAnalyst 600/700/800, SIMAA<br />

6100/6000, and 4110 ZL System 2 EDL<br />

Driver Assembly to the same length as<br />

those on “standard” driver assemblies.<br />

System 2 EDL Modulation Cable<br />

Connects the power supply to the instrument.<br />

(Included with System 2 EDL Power Supply.)<br />

Description Part No. Each (€)<br />

For all instruments (except AAnalyst 100/300) 03030791 185<br />

requiring external EDL modulation<br />

For AAnalyst 100/300 N0410100 153<br />

Included with System 2 Power Supply<br />

EDL Driver Assemblies<br />

EDL Driver Assemblies<br />

Description Part No. Each (€)<br />

For AAnalyst 200/400 N3150131 886<br />

For AAnalyst 600/700/800, SIMAA 4110 ZL 03030997 886<br />

(short cable)<br />

For all models except AAnalyst 600/700/800, 03030793 976<br />

SIMAA 4110 ZL (long cable)<br />

System 2 EDL Power Supply<br />

For use with systems that do not have built-in power<br />

<strong>supplies</strong>. Provides both continuous or modulated operation<br />

of System 2 EDLs. Includes two independently powered<br />

channels with continuously adjustable power output<br />

for each channel, two driver assemblies (03030793),<br />

and modulation cables (03030791 and N0410100).<br />

Description Part No. Each (€)<br />

Power Supply 115 V, 50/60 Hz FCC/VDE approved 03030952 3686<br />

Power Supply 230 V, 50 Hz VDE approved 03030972 3686<br />

Note: EDL System 2 Power Supplies are not<br />

compatible with earlier “System 1” EDLs<br />

Part No.<br />

Each (€)<br />

N3150303 29<br />

Part No.<br />

Each (€)<br />

03030998 74<br />

48


Mercury/Hydride System<br />

MHS-15<br />

Mercury/Hydride Systems are well proven accessories for<br />

high-sensitivity determinations of mercury and metallic<br />

hydride-forming elements, including As, Se, Sb, Te, Bi<br />

and Sn by atomic absorption spectroscopy.<br />

MHS-15 Detection Limits<br />

■<br />

■<br />

■<br />

■<br />

Mercury/Hydride Systems and Supplies<br />

Complete separation of the<br />

element being studied<br />

from its sample matrix<br />

Simple, highly specific<br />

operating procedures<br />

Reliable pneumatic control<br />

of carrier gas and transport<br />

of metallic vapors to the<br />

quartz cell<br />

Conveniently stands<br />

adjacent to the sample<br />

compartment of the<br />

AA spectrometer<br />

Detection Limit* Detection Limit*<br />

Absolute (ng)<br />

Relative (μg/L)<br />

Element (in 10 mL volume) (in 50 mL volume)<br />

As 1.0 0.02<br />

Se 1.0 0.02<br />

Bi 2.0 0.10<br />

Sb 5.0 0.10<br />

Te 2.0 0.05<br />

Hg 1.0 0.02<br />

* EDL lamps were used for all elements.<br />

MHS-15 Mercury/Hydride System<br />

Manually operated system for the high-sensitivity<br />

determination of Hg and hydride-forming elements.<br />

Includes analyzer with sample flask, reagent reservoir,<br />

quartz cell, and cell holder. Switch allows selection of<br />

NaBH 4 or SnCl 2 reductant solution. No electrical<br />

connections are required.<br />

Part No. Each<br />

(€)<br />

B3140760 2439<br />

Quartz Cells<br />

Quartz Cell for MHS-10/15<br />

Part No. B0094415<br />

MHS, Quartz Cells, and Supplies<br />

Quartz Cell for MHS-10 and MHS-15<br />

Complete with graphite cooling<br />

rings and silicone rubber sleeves.<br />

Quartz Cell for MHS-20<br />

Description Part No. Each (€)<br />

With Windows B0097693 1339<br />

Without Windows B0097694 912<br />

Quartz Window for<br />

MHS-20 Quartz Cells<br />

Universal Quartz Cell Holder<br />

To mount MHS-10 or MHS-15 quartz<br />

cell on burner system.<br />

Supplies<br />

For MHS-10/15/20<br />

Quartz Cell for MHS-20<br />

Part No. B0097693<br />

Part No.<br />

Part No.<br />

Each (€)<br />

B3000350 338<br />

Description Part No. Each (€)<br />

Flashback Arrestor B0098640 74<br />

Graphite Cooling Ring for Quartz Cells* B0094413 37<br />

Immersion Tube (Pipette Tip) B0094138 21<br />

Reductant Reservoir (with cap) B0087354 147<br />

Reductant Reservoir (without cap) B0094032 16<br />

Sample Flask** B0094321 38<br />

Silicone Sleeve for Quartz Cells B0098453 1<br />

Transfer Hose B0094140 8<br />

* For MHS-10 and MHS-15 only.<br />

** Specially formed polypropylene reaction vessel with cover.<br />

Each (€)<br />

B0094415 386<br />

Part No.<br />

Each (€)<br />

B0098452 338<br />

Mercury/Hydride Systems and Supplies Atomic Absorption<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

49


Sample Preparation Systems<br />

High Pressure Asher System<br />

Sample Preparation Systems<br />

High Pressure Asher<br />

System Supplies<br />

The Anton Paar HPA-S is a high-performance digestion<br />

system. Using hermetically closed vessels and applying<br />

a maximum temperature of up to 320 °C, the HPA-S<br />

rapidly decomposes even the most complex samples.<br />

The HPA-S provides superior digestion quality.<br />

■ Complete sample mineralization<br />

■ Minimum organic residue<br />

■ No elemental losses<br />

■ No contamination<br />

The HPA-S can be used with a variety of different sized<br />

vessels, making it ideally suited for many different<br />

sample types and analytical applications.<br />

The HPA-S can digest up to 21 samples simultaneously.<br />

The high temperature and pressure is applied in a<br />

hermetically closed system, and the quick and efficient<br />

cooling at the end of the digestion keeps the total<br />

digestion time short.<br />

The samples and reagents are placed in vessels which<br />

are then inserted into the heating block and placed into<br />

the autoclave chamber of the HPA-S. The chamber is then<br />

hermetically closed with a quick-lock lid and pressurized<br />

with nitrogen. Starting at 100 bar (1475 psi), the pressure<br />

rises with increasing temperature up to 130 bar (1920 psi).<br />

This pressure ensures a tight seal during decomposition,<br />

despite the rapidly increasing pressure due to the reaction<br />

process. The system is conventionally heated using a<br />

preselected temperature program.<br />

Atomic Absorption<br />

50


Sample Preparation Systems<br />

High Pressure Asher System Supplies<br />

Heat Trays<br />

Reaction Vessel Racks<br />

Heat trays are heating blocks for insertion of reaction<br />

vessels into the HPA-S pressure chamber.<br />

Heat Tray for 5 Vessels<br />

Aluminum block for insertion of five<br />

quartz digestion vessels — 90 mL.<br />

Heat Tray for 6 Vessels<br />

Aluminum block for insertion of six<br />

(glassy carbon) digestion vessels — 20 mL.<br />

Heat Tray for 7 Vessels<br />

Aluminum block for insertion of seven<br />

quartz digestion vessels — 50 mL.<br />

Heat Tray for 14 Vessels<br />

Aluminum block for insertion of<br />

14 quartz digestion vessels — 15 mL.<br />

Heat Tray for 21 Vessels<br />

Aluminum block for insertion of<br />

21 quartz digestion vessels — 15 mL.<br />

Reaction Vessels and Lids<br />

Part No.<br />

Part No.<br />

Part No.<br />

Each (€)<br />

B0511601 627<br />

Each (€)<br />

B0511523 375<br />

Part No.<br />

Each (€)<br />

B0511602 627<br />

Each (€)<br />

B0511522 604<br />

Part No.<br />

Each (€)<br />

B0511603 710<br />

Reaction Vessel Part No. Each (€) Req.Lid Part No. Each (€)<br />

15 mL Quartz B0511516 76 16 mm B0511517 42<br />

50 mL Quartz B0511514 156 22 mm B0511515 69<br />

90 mL Quartz B0511513 196 22 mm B0511515 69<br />

20 mL Glassy Carbon B0511518 330 B0511519 70<br />

Reaction vessel racks are made of PVC and are<br />

used to hold reaction vessels.<br />

15 mL Reaction Vessel Rack<br />

PVC rack for holding up to 14<br />

15 mL reaction vessels.<br />

20 mL Reaction Vessel Rack<br />

PVC rack for holding up to six 20 mL<br />

glassy carbon reaction vessels.<br />

50 mL Reaction Vessel Rack<br />

PVC rack for holding up to seven<br />

50 mL (or older 30 mL) reaction vessels.<br />

90 mL Reaction Vessel Rack<br />

PVC rack for holding up to five<br />

90 mL reaction vessels.<br />

Reaction Vessel Sets<br />

Reaction vessel sets are complete and include reaction vessels,<br />

lids, heat tray, vessel rack, and PTFE tape for vessel closure.<br />

5 x 90 mL Quartz Reaction Vessel Set<br />

Used for the digestion of five samples<br />

(maximum weight 1.5 g each) in<br />

90 mL quartz vessels.<br />

6 x 20 mL Glassy Carbon Reaction Vessel Set<br />

Used for the digestion of six samples<br />

(maximum weight 0.8 g each) in<br />

20 mL glassy carbon vessels.<br />

7 x 50 mL Quartz Reaction Vessel Set<br />

Used for the digestion of seven samples<br />

(maximum weight 0.8 g each) in<br />

50 mL quartz vessels.<br />

14 x 15 mL Quartz Reaction Vessel Set<br />

Used for the digestion of 14 samples<br />

(maximum weight 0.2 g each) in<br />

15 mL quartz vessels.<br />

Part No.<br />

Part No.<br />

Part No.<br />

Each (€)<br />

B0511526 98<br />

Each (€)<br />

B0511527 98<br />

Part No.<br />

Each (€)<br />

B0511525 98<br />

Each (€)<br />

B0511524 98<br />

Part No.<br />

Part No.<br />

Part No.<br />

Each (€)<br />

B0511502 1980<br />

Each (€)<br />

B0511505 3040<br />

Part No.<br />

Each (€)<br />

B0511503 2380<br />

Each (€)<br />

B0511504 2582<br />

Sample Preparation Systems Atomic Absorption<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

51


Sample Preparation Systems<br />

High Pressure Asher System Supplies<br />

Supplies<br />

Atomic Absorption Sample Preparation Systems<br />

Back-up Ring for O-Ring<br />

Special back-up ring made of<br />

reinforced PTFE compound located<br />

behind O-Ring B0511528.<br />

Extraction Tool<br />

Tool for removing heat trays from<br />

the HPA-S pressure chamber.<br />

O-Ring 107 x 5 FPM with FEP Coating<br />

Special O-Ring for hermetically sealing<br />

the high-pressure chamber safety lid.<br />

PTFE Tape<br />

Rupture Disk, DN 15<br />

Analytically pure PTFE tape for<br />

positioning the lids on the reaction<br />

vessels. The roll is 6.5 m.<br />

Made of corrosion-resistant Inconel ® alloy with a burst<br />

pressure of 180 bar. This allows for overpressure relief in<br />

case of heavy explosions inside the HPA-S. Replace rupture<br />

disk after approximately 750 cycles.<br />

Part No. Each (€)<br />

Support Ring, PEEK<br />

Located behind the back-up ring (B0511529), this support<br />

ring gives mechanical stability<br />

to the entire seal assembly.<br />

Part No. Each (€)<br />

Wrapping Tool for PTFE Tape<br />

Tool for closing the HPA-S vessels<br />

with their lids using PTFE tape by<br />

applying a special wrapping technique.<br />

Part No.<br />

Each (€)<br />

B0511529 20<br />

Part No.<br />

Each (€)<br />

B0511512 310<br />

Part No.<br />

Each (€)<br />

B0511528 56<br />

Part No.<br />

Each (€)<br />

B0511507 17<br />

B0511511 168<br />

B0511530 117<br />

Part No.<br />

Each (€)<br />

B0511506 890<br />

52


Sample Preparation Systems<br />

Multiwave<br />

Multiwave Accessories and Supplies<br />

The Multiwave can be used with a wide variety of reaction vessels allowing the application of optimum reaction conditions<br />

for almost every type of sample. The table below provides an overview of all the available reaction vessel assemblies.<br />

Operation Maximum Maximum Applicable Typical Sample Maximum Filling<br />

Type* Volume Material Pressure Pressure Temperature Rotor Type Weight Volume Part No. Each (€)<br />

HQ20 20 mL Quartz 75 bar 130 bar 300 ºC 6-position 10-200 mg 6 mL<br />

HQ50 50 mL Quartz 75 bar 130 bar 300 ºC 6-position 100-1000 mg 20 mL B0502197 1721<br />

HF50 50 mL TFM 75 bar 130 bar 260 ºC 6-position 50-500 mg 20 mL B0511677 1041<br />

MF100 100 mL TFM (PFA) 30 bar 70 bar 260 ºC 6-position 100-1500 mg 50 mL B0511541 1180<br />

LF100 100 mL PFA 20 bar 70 bar 230 ºC 12-position 100-1000 mg 50 mL B3140380 545<br />

*Type definition: HQ50<br />

HQ20<br />

Characteristics<br />

Small, high temperature vessel for analysis of<br />

micro-samples of a few mg, for ultratrace analysis<br />

Typical Applications<br />

■ Pharmaceuticals<br />

■ Biological and forensic microsamples<br />

■ Biopolymers<br />

HQ50<br />

Characteristics<br />

High temperature vessel for organic material,<br />

for Hg detection, and for ultratrace analysis<br />

Typical Applications<br />

■ Food (high fat)<br />

■ Plastics, Fibers<br />

■ Oil, Grease, Coal<br />

■ Pigments<br />

HF50<br />

Characteristics<br />

For high pressure (HF) applications<br />

of difficult organics and inorganics<br />

Typical Applications<br />

■ Semiconductor<br />

■ Ceramics<br />

■ Oxides<br />

■ Geological material<br />

Volume: 20, 50, 100 mL<br />

Material: Q…Quartz<br />

F…Fluorpolymer (TFM or PFA)<br />

Pressure: H…High<br />

M…Medium<br />

L…Low<br />

Multiwave – shipped prior to January 2002<br />

MF100<br />

Characteristics<br />

Large vessel for versatile applications,<br />

for combined organic-inorganic samples<br />

Typical Applications<br />

■ Soil, sediments<br />

■ Ashes, slags<br />

■ Metals, ores<br />

■ Glass, quartz<br />

LF100<br />

Characteristics<br />

Vessel with high over-pressure tolerance,<br />

for high throughput of “easy” samples<br />

Typical Applications<br />

■ Water, effluent<br />

■ Metals, alloys<br />

■ Plant material<br />

■ Beverages<br />

Sample Preparation Systems Atomic Absorption<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

53


Sample Preparation Systems<br />

Multiwave<br />

Reaction Vessel Assemblies<br />

Atomic Absorption Sample Preparation Systems<br />

Reaction vessel assemblies include a reaction vessel, screw cap and (where appropriate) liner, support vessel,<br />

plug safety disk, base plate, and jacket.<br />

Item Description HQ20 HQ50 HF50 MF100 LF100 Part No. Each (€)<br />

G<br />

A<br />

O<br />

J<br />

N<br />

P<br />

M<br />

Q<br />

D<br />

F<br />

E<br />

L<br />

H<br />

K<br />

I<br />

B<br />

C<br />

R<br />

Quartz vessel Q20 (20 mL) ■ B0511538 549<br />

Quartz vessel Q50EW (50 mL)* ■ B0511674 643<br />

Liner F50 ■ B0511675 152<br />

Liner F100 ■ A B0511532 102<br />

Liner F100-PFA A ■ B0511678 57<br />

Supporting vessel 50 ■ B0511676 230<br />

Supporting vessel 100 ■ B0511533 168<br />

Supporting vessel with thread ■ B3140382 164<br />

Plug ■ ■ ■ ■ B0502201 123<br />

Plug B ■ B0511539 271<br />

Safety Disk H ■ ■ ■ B0502202 13<br />

Safety Disk M ■ ■ B0511535 12<br />

Seal 25, pkg. 6 ■ ■ ■ B0502203 135<br />

Seal 40, pkg. 6 ■ ■ B0511534 139<br />

Vessel base plate ■ ■ ■ B0502204 148<br />

Bomb jacket PEEK ■ ■ ■ ■ N/A<br />

Screw cap PEEK ■ ■ ■ ■ N/A<br />

Screw cap L PEEK ■ B3140383 234<br />

* B0511674 replaces former B0502198, quartz vessel, 50 mL<br />

■ Part of respective pressure vessel type<br />

A – possible alternative item<br />

E<br />

F<br />

G<br />

I<br />

C<br />

B<br />

H<br />

HQ20 High Pressure Quartz<br />

Reaction Vessel Assembly<br />

E<br />

D<br />

A<br />

C<br />

I<br />

H<br />

B<br />

HQ50 Part No. B0502197<br />

High Pressure Quartz<br />

Reaction Vessel Assembly<br />

D<br />

H<br />

O<br />

I<br />

B<br />

C<br />

P<br />

HF50 Part No. B0511677<br />

High Pressure TFM<br />

Reaction Vessel Assembly<br />

E<br />

D<br />

L<br />

K<br />

J<br />

C<br />

MF100 Part No. B0511541<br />

Medium Pressure (PFA or TFM)<br />

Reaction Vessel Assembly<br />

M<br />

B<br />

L<br />

K<br />

D<br />

N<br />

R<br />

Q<br />

LF100 Part No. B3140380<br />

Low Pressure PFA<br />

Reaction Vessel Assembly<br />

54


Sample Preparation Systems<br />

Multiwave<br />

Reaction Vessel Racks<br />

PVC rack for holding up to six reaction vessels.<br />

Description Part No. Each (€)<br />

HQ20 B0511540 154<br />

HQ50 or HF50 B0511546 86<br />

MF100 or LF100 B0511546 86<br />

Rotors and Rotor Assemblies<br />

Reaction<br />

Vessel Type Description Part No. Each (€)<br />

HQ20 Rotor Only B0502196 4017<br />

HF50 Rotor Assembly B0511679 7400<br />

(includes Rotor<br />

and 6 vessels)<br />

Reaction Vessel Assembly B0511677 1041<br />

Rotor Only B0502196 4017<br />

HQ50 Rotor Assembly B0502195 8000<br />

(includes Rotor<br />

and 6 vessels)<br />

Reaction Vessel Assembly B0502197 1721<br />

Rotor Only B0502196 4017<br />

MF100 Rotor Assembly B0511537 9800<br />

(includes Rotor<br />

and 6 vessels)<br />

Reaction Vessel Assembly B0511541 1180<br />

Rotor Only B0502196 4017<br />

LF100 Rotor Assembly B3140386 8600<br />

(includes Rotor,<br />

1sensor vessel, and 11<br />

pressure vessles)<br />

Reaction Vessel Assembly* B3140381 1410<br />

Reaction Vessel Assembly** B3140380 545<br />

Rotor Only B3140387 2656<br />

* Sensor Vessel<br />

** Pressure Vessel<br />

Sample Preparation Systems Atomic Absorption<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

55


Sample Preparation Systems<br />

Multiwave 3000<br />

Atomic Absorption Sample Preparation Systems<br />

Multiwave 3000<br />

The 16-position rotor maximizes productivity.<br />

Rotor 8 for advanced<br />

digestions offers simultaneous<br />

pressure sensing in all vessels.<br />

Multiwave 3000 Accessories<br />

and Supplies<br />

The Multiwave 3000<br />

The Anton Paar Multiwave 3000 is a versatile and powerful<br />

microwave sample preparation system for safe high-pressure<br />

acid digestions of all types of organic and inorganic samples.<br />

The Multiwave 3000 provides dramatically improved sample<br />

capacity, a more powerful dual-magnetron design, superior<br />

sensors requiring no cables and built-in methods. It offers<br />

unique pressure monitoring and a multilevel safety system<br />

that give you the performance and safety you want.<br />

Important user benefits of the Multiwave 3000 are:<br />

■<br />

■<br />

■<br />

■<br />

■<br />

■<br />

■<br />

■<br />

■<br />

■<br />

■<br />

■<br />

Reduced analysis times by fast digestion, using rapid<br />

microwave heating and short cool-down times<br />

Superior digestion quality using closed vessels and<br />

simultaneous high pressure and high temperature<br />

Time-saving, easy operation by simplified method<br />

development and easy, intuitive software<br />

Maximum safety provided by easy handling, sophisticated<br />

sensors, and a library of tested methods<br />

1400 W microwave power ensures fast heating<br />

Unpulsed microwave power from 0 to 1400 W<br />

for precise control of critical reactions<br />

Reliable remote sensors for convenient operation<br />

Fast, built-in cooling system to reduce total cycle time<br />

resulting in improved productivity<br />

Intuitive software for easy routine operation<br />

and documentation<br />

Large PTFE-coated cavity for rough laboratory environments<br />

Proven safety system to minimize hazards from<br />

violent reactions<br />

Modular, industrial-type design offers individual<br />

choice of configurations<br />

Multiwave is a trademark of Anton Paar, GmbH<br />

56


Sample Preparation Systems<br />

Multiwave 3000 Digestion Rotors<br />

Rotor 8 Consumables and Vessels<br />

Pressure Vessel XF100<br />

Complete reaction vessel for various<br />

applications at elevated pressure<br />

and temperature.<br />

Specifications<br />

Part No.<br />

Each (€)<br />

N3142345 960<br />

Volume:<br />

100 mL<br />

Working pressure:<br />

60 bar (870 psi)<br />

Opening pressure:<br />

120 bar (1740 psi)<br />

Max. temperature: 260 °C<br />

Components Part No. Each (€)<br />

1 PEEK Protective Cap N3142353 39<br />

2 Safety Disk Holder X N3142350 27<br />

3 Safety Disk X N3142349 11<br />

4 PEK Seal Holder N3142351 141<br />

5 PEEK Center Ring N3142354 25<br />

6 Syringe Connector N3141022 17<br />

7 Venting Screw N3141021 21<br />

8 PTFE-TFM Seal N3141015 72<br />

9 100 mL TFM liner N3141014 130<br />

10 H100 Ceramics Jacket N3141019 388<br />

11 PEEK Protective Casing N3142352 115<br />

Pressure Vessel XQ80<br />

Complete pressure vessel for<br />

digestions at extreme conditions.<br />

Specifications<br />

Part No.<br />

Each (€)<br />

N3142346 1310<br />

Volume:<br />

80 mL<br />

Working pressure:<br />

80 bar (1160 psi)<br />

Opening pressure:<br />

120 bar (1740 psi)<br />

Max. temperature: 300 °C<br />

Components Part No. Each (€)<br />

1 PEEK Protective Cap N3142353 39<br />

2 Safety Disk Holder X N3142350 27<br />

3 Safety Disk X N3142349 11<br />

4 PEK Seal Holder N3142351 141<br />

5 PEEK Center Ring N3142354 25<br />

6 Syringe Connector N3141022 17<br />

7 Venting Screw N3141021 21<br />

11 PEEK Protective Casing N3142352 115<br />

12 PTFE-TFM Seal XQ N3142348 121<br />

13 Quartz Vessel N3142347 820<br />

XF100<br />

1<br />

2<br />

3<br />

4<br />

5<br />

XQ80<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

9<br />

10<br />

11<br />

6<br />

7<br />

12<br />

13<br />

11<br />

Sample Preparation Systems Atomic Absorption<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

57


Sample Preparation Systems<br />

Multiwave 3000 Digestion Rotors<br />

Atomic Absorption Sample Preparation Systems<br />

1<br />

1<br />

2<br />

Immersion Tube<br />

with Seal XF<br />

2<br />

Immersion Tube<br />

with Seal XQ<br />

3<br />

4<br />

6<br />

7<br />

8<br />

3<br />

4<br />

9<br />

7<br />

8<br />

5<br />

5<br />

Rotor 8 Consumables and Vessels<br />

Immersing Temperature Probe T-Probe for Rotor 8<br />

Immersion Tube with Seal XF<br />

Assembly of a special seal holder<br />

with seal for XF100-vessels.<br />

Immersion Tube with Seal XQ<br />

Assembly of a special seal holder<br />

with seal for XQ80-vessels.<br />

Immersing temperature probe<br />

for precise measurement of the<br />

solution temperature in Rotor<br />

8XF100 and XQ80. The sensor<br />

head includes a gas-bulb<br />

thermometer for monitoring<br />

the decomposition<br />

temperature up to 280 °C.<br />

The sensor is hermetically<br />

shielded by a sapphire<br />

thermowell. Its microwavetransparent<br />

design does not<br />

interfere with the microwave<br />

field. The installation is very<br />

easy and does not require any<br />

electrical connections, cables<br />

or hoses. Requires Immersion<br />

Tube with either Seal XQ<br />

(N3142410) or Seal XF<br />

(N3142411).<br />

Part No. Each (€)<br />

N3142409 2190<br />

Part No.<br />

Each (€)<br />

N3142411 980<br />

Part No.<br />

Each (€)<br />

N3142410 980<br />

Components Part No. Each (€)<br />

1 Safety Disk Holder X N3142350 27<br />

2 Safety Disk X N3142349 11<br />

3 Syringe Connector N3141022 17<br />

4 Seal Holder X for T-Probe N3142415 141<br />

5 Venting Screw N3141021 21<br />

6 Seal XF* N3141016 92<br />

7 Husk N3142416 7<br />

8 Immersion Tube Sapphire X N3142413 653<br />

9 Seal XQ for T-Probe N3142412 133<br />

* Also used for Rotor 16 Pressure/Temperature Sensor.<br />

58


Sample Preparation Systems<br />

Multiwave 3000 Digestion Rotors<br />

Rotor 8 Spare Parts<br />

Rotor 8 (without Vessels)<br />

Complete 8 position rotor<br />

without reaction vessels.<br />

Part No.<br />

Each (€)<br />

N3142355 6700<br />

Components Part No. Each (€)<br />

1<br />

2<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

Rotor 8 Lid<br />

Liner Extractor Bolt 8<br />

Rotor Upper Plate (Assembled)<br />

Fastening Screw<br />

Thumbwheel<br />

Insulating Bushing*<br />

Bottom Guard<br />

N3142364<br />

N3142366<br />

N3142356<br />

N3142485<br />

N3142363<br />

N3142486<br />

N3142357<br />

162<br />

68<br />

5000<br />

99<br />

23<br />

18<br />

290<br />

8<br />

9<br />

10<br />

Bottom Load Ring Al Green<br />

Tension Bar Short<br />

Protection Hose 8<br />

N3142431<br />

N3142430<br />

N3142360<br />

1673<br />

140<br />

13<br />

* Used with Black Rotor 8 upper plates shipped prior to July 2005.<br />

1<br />

Rotor 8 for Advanced Digestions<br />

2<br />

9<br />

10<br />

3<br />

7<br />

4<br />

5<br />

6<br />

8<br />

Sample Preparation Systems Atomic Absorption<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

59


Sample Preparation Systems<br />

Multiwave 3000 Digestion Rotors<br />

11<br />

10<br />

Rotor 16 Consumables and Vessels<br />

Sample Preparation Systems<br />

5<br />

Pressure Vessel MF100<br />

(N3141011) respectively<br />

HF100 (N3141012)<br />

3<br />

8<br />

1<br />

6 7<br />

9<br />

Pressure Vessel MF100 MW3000<br />

Complete reaction vessel for routine<br />

and quality control applications.<br />

Specifications<br />

Volume:<br />

100 mL<br />

Working pressure:<br />

20 bar (290 psi)<br />

Opening pressure:<br />

70 bar (1000 psi)<br />

Max. temperature: 200 °C<br />

Pressure Vessel HF100 MW3000<br />

Complete reaction vessel for<br />

versatile applications.<br />

Specifications<br />

Part No.<br />

Volume:<br />

100 mL<br />

Working pressure:<br />

40 bar (580 psi)<br />

Opening pressure:<br />

70 bar (1000 psi)<br />

Max. temperature: 240 °C<br />

Each (€)<br />

N3141011 386<br />

Part No.<br />

Each (€)<br />

N3141012 660<br />

11<br />

5<br />

12<br />

10<br />

14<br />

13<br />

4<br />

9<br />

Components Part No. Each (€)<br />

1 100 mL TFM Liner N3141014 130<br />

6 M100 PEEK Vessel Jacket N3141018 92<br />

3 PTFE-TFM Seal N3141015 72<br />

5 Safety Disk N3141017 8<br />

8 PEK Screw Cap N3141020 143<br />

7 H100 Ceramics Jacket N3141019 388<br />

9 Venting Screw N3141021 21<br />

Package of 16 Venting Screws N3142452 220<br />

10 Syringe Connector N3141022 17<br />

11 Safety Disk Holder M&H N3141023 25<br />

Pressure/Temperature Sensor Accessory<br />

for Rotor 16<br />

Pressure/Temperature<br />

Sensor Accessory<br />

15<br />

Sensor screw cap for simultaneous<br />

pressure and internal temperature<br />

measurement of one MF or HF vessel.<br />

Part No.<br />

Each (€)<br />

N3141005 3340<br />

Pressure Sensor Accessory for Rotor 16<br />

Atomic Absorption<br />

11<br />

Pressure Sensor<br />

Accessory<br />

5<br />

10<br />

14<br />

13<br />

3<br />

9<br />

Sensor screw cap for pressure<br />

measurement of one MF or HF vessel.<br />

Part No.<br />

Each (€)<br />

N3142418 2200<br />

Components Part No. Each (€)<br />

4 Seal p/T Sensor N3141016 92<br />

12 Immersion Tube Sapphire M&H N3142013 680<br />

13 O-Ring 38x1.5 FPM N3142400 2<br />

14 Seal Holder for p/T Sensor N3142399 153<br />

15 Husk N3142416 7<br />

Husk Assembly Tool N3142456 2<br />

60


Sample Preparation Systems<br />

Multiwave 3000 Digestion Rotors<br />

Rotor 16 Spare Parts<br />

Rotor 16 (without Vessels)<br />

Complete 16-position rotor without<br />

reaction vessels and sensors.<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

Part No.<br />

Each (€)<br />

N3141025 1180<br />

Components Part No. Each (€)<br />

Rotor 16 Body N3141026 100<br />

Rotor 16 Lid N3141027 72<br />

Rotor 16 Tray N3141028 139<br />

Rotor Base Ring N3141029 158<br />

Vessel Holder N3141030 45<br />

Seal for Vessel Holder N3141031 17<br />

Cheese Head Screw N3142398 2<br />

Liner Extractor Bolt N3141032 68<br />

Rotor 16 for routine digestions<br />

Spare Parts for the Rotor 16<br />

Rotor 16<br />

2<br />

1<br />

4<br />

7<br />

2<br />

3<br />

8<br />

5<br />

6<br />

1<br />

Sample Preparation Systems Atomic Absorption<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

61


Sample Preparation Systems<br />

Multiwave 3000 Drying and Evaporation Rotors<br />

Rotor 1 DRY Supplies<br />

Atomic Absorption Sample Preparation Systems<br />

1<br />

4<br />

Rotor 8 EVAP Supplies<br />

1 3<br />

9<br />

10<br />

11<br />

12<br />

2<br />

3<br />

2 4<br />

5<br />

6<br />

7<br />

8<br />

13<br />

14<br />

1<br />

2<br />

3<br />

4<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

9<br />

10<br />

11<br />

12<br />

13<br />

14<br />

Components Part No. Each (€)<br />

Filter Disk Borosilicate Glass N3142000 9<br />

D=30 Porosity 0<br />

Glass Tube N3142001 274<br />

Desiccator Plate N3142002 102<br />

O-Ring N3142003 2<br />

28.24 x 2.62 Silicone<br />

Components Part No. Each (€)<br />

Hose Connector 8/8 N3142370 131<br />

Connection Hose N3142367 29<br />

Hose Connector Nut N3142371 80<br />

Syringe Filter N3142374 8<br />

Screw Cap EVAP N3142373 96<br />

Seal EVAP N3142372 66<br />

Vessel Holder N3141030 45<br />

Seal for Vessel Holder N3141031 17<br />

Liner Extractor Bolt 16 N3141032 68<br />

Rotor Tray EVAP N3142369 133<br />

Rotor 16 Body N3141026 100<br />

Rotor Base Ring N3141029 158<br />

Cheese Head Screw N3142398 2<br />

Ring Weight N3142368 39<br />

62


Sample Preparation Systems<br />

Multiwave 3000 Solvent Extraction Rotors<br />

Rotor 8 SOLV Consumables<br />

and Vessels<br />

Pressure/Temperature Sensor Accessory SOLV<br />

Sensor screw cap for simultaneous<br />

pressure and temperature measurement<br />

in Pressure Vessels SOLV100.<br />

Specifications<br />

Temperature range: 0-300 °C<br />

Pressure range:<br />

0-86 bar (1250 psi)<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

Components Part No. Each (€)<br />

Immersion Tube Sapphire M&H N3142013 680<br />

Seal Holder N3142429 153<br />

for p/T Sensor Accessory SOLV<br />

Safety Disk SOLV N3142427 13<br />

Hose Connector SOLV N3142437 36<br />

Screw PEEK N3142436 3<br />

Seal p/T SOLV N3142425 102<br />

Husk N3142416 7<br />

Pressure/Temperature Sensor Adapter<br />

Used to convert Pressure Temperature Accessory<br />

(N3141005) which is used for acid digestion into a sensor<br />

for solvent extraction.<br />

Specifications<br />

Working pressure:<br />

Opening pressure:<br />

8<br />

18 bar (252 psi)<br />

22 bar (300 psi)<br />

Components Part No. Each (€)<br />

Adapter SOLV N3142420 250<br />

Pressure Vessel SOLV100<br />

Complete reaction vessel for solvent<br />

extraction applications.<br />

Specifications<br />

Part No.<br />

Working pressure:<br />

18 bar (261 psi)<br />

Opening pressure:<br />

22 bar (319 psi)<br />

Max. temperature: 200°<br />

Each (€)<br />

N3142419 3590<br />

Part No.<br />

Each (€)<br />

N3142423 390<br />

Components Part No. Each (€)<br />

PEEK Screw N3142436 3<br />

Hose Connector N3142437 36<br />

Safety Disk N3142427 13<br />

PEK Screw Cap N3142428 143<br />

Seal SOLV N3142424 82<br />

Liner F100TFM N3141014 130<br />

Vessel Jacket M100 PEEK N3141018 92<br />

1<br />

2<br />

3<br />

4<br />

7<br />

8<br />

{<br />

7<br />

1<br />

5<br />

6<br />

4<br />

5<br />

3<br />

6<br />

2<br />

Sample Preparation Systems Atomic Absorption<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

63


Sample Preparation Systems<br />

Multiwave 3000 Solvent Extraction Rotors and System Spare Parts<br />

Rotor 8 SOLV Spare Parts<br />

Atomic Absorption Sample Preparation Systems<br />

Seal Forming Device<br />

For Rotor XQ80<br />

For Rotor MF100,<br />

HF100, XF100<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

System Spare Parts<br />

Exhaust Silencer<br />

Seal Forming Device for<br />

8 Caps<br />

Keyboard USA<br />

Quartz Lifting Hook<br />

Quartz Weighing Scoop<br />

Rack 16<br />

Components Part No. Each (€)<br />

Rotor 16 Lid N3141027 72<br />

Level Indicator N3142438 33<br />

Liner Extractor Bolt 16 N3141032 68<br />

Rotor Tray 8SOLV N3142435 150<br />

Vessel Holder N3141030 45<br />

Seal for Vessel Holder N3141031 17<br />

Rotor 16 Body N3141026 100<br />

Sound Insulator Hood<br />

Part No.<br />

Each (€)<br />

N3142453 360<br />

Part No.<br />

Each (€)<br />

N3141009 310<br />

Part No.<br />

Each (€)<br />

N3141010 170<br />

Part No.<br />

Each (€)<br />

N3142451 78<br />

Part No.<br />

Each (€)<br />

N3142450 96<br />

Part No.<br />

Each (€)<br />

N3142449 98<br />

Part No.<br />

Each (€)<br />

N3142454 98<br />

64


Standards<br />

PerkinElmer Pure Atomic Spectroscopy Standards<br />

Whatever your application,<br />

you can depend on PerkinElmer Pure<br />

standards to yield reliable, accurate results.<br />

PerkinElmer offers a wide selection of atomic absorption<br />

calibration standards. Each solution is supplied with a<br />

comprehensive Certificate of Analysis that documents the<br />

quality. To ensure that your measurements are accurate, you<br />

can rely on our certificates to provide complete information.<br />

Quality<br />

PerkinElmer Pure standards are prepared gravimetrically<br />

from high-purity metals and salts, using high-purity reagents.<br />

■ ASTM Type I, filtered water minimizes cations, anions, and colloids;<br />

resistivity is maintained in the 18-megohm range.<br />

■ Acids used are the highest purity.<br />

■ Semi-micro analytical balances and Class A volumetric<br />

glassware are used, and the bottles are subjected to a stringent<br />

leaching/cleaning process.<br />

■ Following preparation, standards are analyzed for the major element<br />

as well as trace impurities. The results of the analysis are provided<br />

on the Certificate of Analysis.<br />

Reliability<br />

Single-element standards are<br />

measured by three methods:<br />

1. DC arc analysis of starting materials for<br />

trace impurities (semi-quantitative).<br />

2. Gravimetric, “wet” assay for<br />

major constituents.<br />

3. ICP check of the final solution.<br />

The results of these three<br />

analyses are reported on<br />

the Certificate of Analysis.<br />

NIST or NBS SRMs used for the ICP check<br />

are also reported on the Certificate of Analysis.<br />

Safety<br />

We ship standards to comply with both DOT and<br />

IATA regulations to ensure their safe delivery to you.<br />

PerkinElmer Pure Atomic<br />

Spectroscopy Standards are<br />

manufactured for PerkinElmer<br />

to the highest quality standards.<br />

Features<br />

■ ISO 9001 accredited by Underwriters Laboratories including<br />

comprehensive continuous improvement, product recall, corrective action<br />

request, and other quality maintenance and improvement programs<br />

■ Accreditation by NVLAP/NIST as an EPA performance testing provider<br />

■ Product labeling meets OSHA and California labeling standards<br />

■ Bottles are low-density polyethylene from industry standard Nalge<br />

Corporation and are pre-leached and pre-treated for increased product<br />

stability and purity<br />

■ High-purity acids and ASTM Type I water used in all manufacturing,<br />

as reported on the Certificate of Analysis<br />

■ Traceability directly to NIST standard reference materials, not independent<br />

sources or secondary NIST SRMs and reported on the Certificate of Analysis<br />

■ Wet assays on all single-element products via standard, accepted wet<br />

methods and traceable directly to NIST SRM to +/-0.5% of true value<br />

and reported on the Certificate of Analysis<br />

■ All solutions tested and confirmed for the absence of interfering anions,<br />

e.g. chloride, bromide, etc.<br />

■ Twelve months guaranteed stability +/-0.5% for all major analytes<br />

for all products<br />

65


Standards<br />

PerkinElmer Pure Atomic Absorption Standards<br />

Atomic Absorption Standards<br />

Alternate Trace Metal Drinking<br />

Pollution and Wastewater Standards<br />

Alternate Metals I<br />

Matrix/Vol. Concentration of Element Part No. Each (€)<br />

2% HNO 3 /100 mL 20 μg/mL Aluminum N9300214 190<br />

5 μg/mL Antimony<br />

5 μg/mL Beryllium<br />

10 μg/mL Cobalt<br />

10 μg/mL Copper<br />

20 μg/mL Iron<br />

10 μg/mL Manganese<br />

10 μg/mL Nickel<br />

5 μg/mL Thallium<br />

20 μg/mL Vanadium<br />

10 μg/mL Zinc<br />

Alternate Metals II<br />

Matrix/Vol. Concentration of Element Part No. Each (€)<br />

2% HNO 3 /100 mL 500 μg/mL Calcium N9300215 114<br />

100 μg/mL Magnesium<br />

100 μg/mL Potassium<br />

500 μg/mL Sodium<br />

GFAAS Mixed Standard<br />

Matrix/Vol. Concentration of Element Part No. Each (€)<br />

5% HNO 3 100 μg/mL Aluminum N9300244 228<br />

w/trace of HF/100 mL 100 μg/mL Antimony<br />

100 μg/mL Arsenic<br />

50 μg/mL Barium<br />

5 μg/mL Beryllium<br />

5 μg/mL Cadmium<br />

20 μg/mL Chromium<br />

50 μg/mL Cobalt<br />

50 μg/mL Copper<br />

20 μg/mL Iron<br />

100 μg/mL Lead<br />

20 μg/mL Manganese<br />

50 μg/mL Nickel<br />

100 μg/mL Selenium<br />

10 μg/mL Silver<br />

100 μg/mL Thallium<br />

CLP Standards<br />

Instrument Calibration Standards<br />

All the solutions you need for daily calibration of your ICP<br />

and HGA ® for CLP analyses<br />

Remember to prepare your calibration standards fresh for<br />

each analysis and discard after use<br />

Dilute with high-purity 5% HNO 3<br />

Instrument Calibration Standard 1<br />

Matrix/Vol. Concentration of Element Part No. Each (€)<br />

5% HNO 3 /100 mL 5,000 μg/mL Calcium N9300218 190<br />

5,000 μg/mL Magnesium<br />

5,000 μg/mL Potassium<br />

5,000 μg/mL Sodium<br />

Instrument Calibration Standard 2<br />

Matrix/Vol. Concentration of Element Part No. Each (€)<br />

5% HNO 3 /100 mL 100 μg/mL Chromium N9300219 126<br />

150 μg/mL Manganese<br />

400 μg/mL Nickel<br />

100 μg/mL Silver<br />

200 μg/mL Sodium<br />

Instrument Calibration Standard 3<br />

Matrix/Vol. Concentration of Element Part No. Each (€)<br />

5% HNO 3 /100 mL 2,000 μg/mL Aluminum N9300220 165<br />

2,000 μg/mL Barium<br />

50 μg/mL Beryllium<br />

500 μg/mL Cobalt<br />

250 μg/mL Copper<br />

1,000 μg/mL Iron<br />

500 μg/mL Vanadium<br />

Instrument Calibration Standard 4<br />

Matrix/Vol. Concentration of Element Part No. Each (€)<br />

5% HNO 3 /100 mL 100 μg/mL Arsenic N9300221 114<br />

50 μg/mL Cadmium<br />

50 μg/mL Lead<br />

50 μg/mL Selenium<br />

100 μg/mL Titanium<br />

Instrument Calibration Standard 5<br />

Matrix/Vol. Concentration of Element Part No. Each (€)<br />

2% HNO 3 /500 mL 1,000 μg/mL Antimony N9300101 101<br />

Instrument Calibration Standard 6<br />

Matrix/Vol. Concentration of Element Part No. Each (€)<br />

10% HNO 3 /500 mL 1,000 μg/mL Mercury N9300133 101<br />

66


Standards<br />

PerkinElmer Pure Atomic Absorption Standards<br />

Contract Required Detection Limits<br />

(CRDL) Standard<br />

Used for Initial Calibration Verification (ICV). Contains all the elements on<br />

the Inorganic Target Analyte List (TAL) in one solution. Select only those<br />

elements for verification that you will subsequently determine. Dilute<br />

10-fold prior to use for ICP analysis. Dilute 500-fold prior to use for<br />

graphite furnace analysis.<br />

Initial Calibration Verification Standard<br />

Matrix/Vol. Concentration of Element Part No. Each (€)<br />

5% HNO 3 /500 mL 200 μg/mL Aluminum N9300224 738<br />

60 μg/mL Antimony<br />

10 μg/mL Arsenic<br />

200 μg/mL Barium<br />

5 μg/mL Cadmium<br />

500 μg/mL Calcium<br />

10 μg/mL Chromium<br />

50 μg/mL Cobalt<br />

25 μg/mL Copper<br />

100 μg/mL Iron<br />

3 μg/mL Lead<br />

500 μg/mL Magnesium<br />

15 μg/mL Manganese<br />

40 μg/mL Nickel<br />

500 μg/mL Potassium<br />

5 μg/mL Selenium<br />

10 μg/mL Silver<br />

500 μg/mL Sodium<br />

10 μg/mL Thallium<br />

50 μg/mL Vanadium<br />

20 μg/mL Zinc<br />

AA Test Mix. Recommended for use in checking sensitivity for eight<br />

elements commonly determined by Flame AA.<br />

Contract Required Detection Limits (CRDL) Standard<br />

Matrix/Vol. Concentration of Element Part No. Each (€)<br />

2% HCL/100 mL 50 μg/mL Calcium 02900540 126<br />

50 μg/mL Chromium<br />

50 μg/mL Copper<br />

50 μg/mL Iron<br />

50 μg/mL Nickel<br />

20 μg/mL Potassium<br />

10 μg/mL Sodium<br />

10 μg/mL Zinc<br />

Groundwater and Wastewater<br />

Pollution Control Check Standards<br />

Use as a daily control standard<br />

Check the accuracy and precision of your analysis<br />

Refer to U.S. EPA methods manual 600/4-79-020, “Methods for Chemical<br />

Analysis of Water and Wastes”: Trace metals I, II, and III methods.<br />

Trace Metals I<br />

Matrix/Vol. Concentration of Element Part No. Each (€)<br />

5% HNO 3 /100 mL 500 μg/mL Aluminum N9300211 228<br />

100 μg/mL Arsenic<br />

100 μg/mL Beryllium<br />

25 μg/mL Cadmium<br />

100 μg/mL Chromium<br />

100 μg/mL Cobalt<br />

100 μg/mL Copper<br />

100 μg/mL Iron<br />

100 μg/mL Lead<br />

100 μg/mL Manganese<br />

5 μg/mL Mercury<br />

100 μg/mL Nickel<br />

25 μg/mL Selenium<br />

250 μg/mL Vanadium<br />

100 μg/mL Zinc<br />

Trace Metals II<br />

Matrix/Vol. Concentration of Element Part No. Each (€)<br />

2% HNO 3 /100 mL 20 μg/mL Antimony N9300212 88<br />

10 μg/mL Silver<br />

20 μg/mL Thallium<br />

Trace Metals III<br />

Matrix/Vol. Concentration of Element Part No. Each (€)<br />

2% HNO 3 /100 mL 500 μg/mL Barium N9300213 152<br />

500 μg/mL Calcium<br />

100 μg/mL Magnesium<br />

500 μg/mL Molybdenum<br />

100 μg/mL Potassium<br />

500 μg/mL Sodium<br />

Reagents<br />

Antifoaming Silicone Emulsion B0507226 91<br />

Dow Corning DB 110 A, 500 mL. Controls foaming during<br />

reaction when using the MHS-10, MHS-15, or MHS-20.<br />

Triton X-100 Wetting Agent N9300260 24<br />

Glycerol B3141064 29<br />

Matrix Modifiers for Graphite Furnace AA<br />

Modifier Concentration Volume Part No. Each (€)<br />

Mg(NO 3 ) 2 1% Mg (as nitrate) 100 B0190634 71<br />

Pd 10% Pd (as nitrate) 50 B0190635 249<br />

NH 4 H 2 PO 4 10% NH 4 H 2 PO 4 100 N9303445 101<br />

High-purity compounds minimize the risk of contamination<br />

Optimum graphite furnace program can be used due to<br />

reduced analyte volatility<br />

Convenient, ready-to-use<br />

Standards Atomic Absorption<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

67


Standards<br />

PerkinElmer Pure Atomic Absorption Standards<br />

Single-Element Calibration Standards<br />

The single-element standards listed have a concentration of 1,000 μg/mL in aqueous solution. All<br />

are available in volumes of 500 mL, while selected standards are also available in 100 mL volumes.<br />

Atomic Absorption Standards<br />

Starting 500 mL 100 mL<br />

Element Symbol Matrix Material Part No. Each (€) Part No. Each (€)<br />

Aluminum Al 2% HNO 3 Al(NO 3 ) 3<br />

•9H 2 O N9300100 101 N9300184 50<br />

Antimony Sb 2% HNO 3 Sb 2 O 3 N9300101 101 N9300207 50<br />

Arsenic As 2% HNO 3 H 3 AsO 4<br />

• 1⁄2 H 2 0 N9300102 101 N9300180 50<br />

Barium Ba 2% HNO 3 BaCO 3 N9300103 101 N9300181 50<br />

Beryllium Be 2% HNO 3 Be 4 O(C 2 H 3 O 2 ) 6 N9300104 101 N9300172 50<br />

Bismuth Bi 10% HNO 3 Bi N9300105 101 N9303761 50<br />

Boron B H 2 O (NH 4 ) 2 B 4 O 7<br />

•4H 2 O N9300106 101<br />

Cadmium Cd 2% HNO 3 Cd N9300107 101 N9300176 50<br />

Calcium Ca 2% HNO 3 CaCO 3 N9300108 101 N9303763 50<br />

Cerium Ce 2% HNO 3 Ce(NO 3 ) 3<br />

•6H 2 O N9300110 101<br />

Cesium Cs 2% HNO 3 CsNO 3 N9300111 114<br />

Chromium Cr 2% HNO 3 Cr(NO 3 ) 3<br />

•9H 2 O N9300112 101 N9300173 50<br />

Cobalt Co 2% HNO 3 CoCO 3 N9300113 101 N9303766 50<br />

Copper Cu 2% HNO 3 Cu N9300114 101 N9300183 50<br />

Dysprosium Dy 2% HNO 3 Dy 2 O 3 N9300115 114<br />

Erbium Er 2% HNO 3 Er 2 O 3 N9300116 114<br />

Europium Eu 2% HNO 3 Eu 2 O 3 N9300117 114<br />

Gadolinium Gd 2% HNO 3 Gd 2 O 3 N9300118 114<br />

Gallium Ga 2% HNO 3 Ga N9300119 114<br />

Germanium Ge H 2 O (NH 4 ) 2 Ge(C 2 O 4 ) 3<br />

•XH 2 O N9300120 114<br />

Gold Au 10% HCl Au N9300121 228 N9303759 126<br />

Hafnium Hf 2% HCl HfOCl 2<br />

•8H 2 O N9300122 114 N9303775 50<br />

Holmium Ho 2% HNO 3 Ho 2 O 3 N9300123 114<br />

Indium In 2% HNO 3 In N9300124 114<br />

Iridium Ir 10% HCl IrCl 3<br />

•3H 2 O N9300125 228<br />

Iron Fe 2% HNO 3 Fe N9300126 101 N9303771 50<br />

Lanthanum La 2% HNO 3 La 2 O 3 N9300127 101<br />

Lead Pb 2% HNO 3 Pb N9300128 101 N9300175 50<br />

Lithium Li 2% HNO 3 Li 2 CO 3 N9300129 101<br />

Lutetium Lu 2% HNO 3 Lu 2 O 3 N9300130 381<br />

Magnesium Mg 2% HNO 3 Mg N9300131 101 N9300179 50<br />

Manganese Mn 2% HNO 3 Mn(C 2 H 3 O 2 ) 3<br />

•2H 2 O N9300132 101 N9303783 50<br />

Mercury* Hg 10% HNO 3 Hg N9300133 101 N9300174 50<br />

* Also available at 10 μg/mL as Part No. N9300253.<br />

68


Standards<br />

PerkinElmer Pure Atomic Absorption Standards<br />

Starting 500 mL 100 mL<br />

Element Symbol Matrix Material Part No. Each (€) Part No. Each (€)<br />

Molybdenum Mo H 2 O (NH 4 )6Mo 7 O 24<br />

•4H 2 O N9300134 101 N9303784 50<br />

Neodymium Nd 2% HNO 3 Nd 2 O 3 N9300135 114<br />

Nickel Ni 2% HNO 3 Ni N9300136 101 N9300177 50<br />

Niobium Nb H 2 O NH 4 NbF6 N9300137 114<br />

Palladium Pd 10% HCl (NH 4 ) 2 PdCl 4 N9300138 228 N9303789 126<br />

Phosphorus P H 2 O NH 4 H 2 PO 4 N9300139 101 N9303788 50<br />

Platinum Pt 10% HCl H2PtCl6•XH 2 O N9300140 228<br />

Potassium K 2% HNO 3 KNO 3 N9300141 101 N9303779 50<br />

Praseodymium Pr 2% HNO 3 Pr 6 O 11 N9300142 114<br />

Rhenium Re H 2 O (NH 4 )2ReO 4 N9300143 228<br />

Rhodium Rh 10% HCl RhCl3•3H 2 O N9300144 381<br />

Rubidium Rb 2% HNO 3 RbNO 3 N9300145 101<br />

Ruthenium Ru 10% HCl RuCl 3<br />

•3H 2 O N9300146 228<br />

Samarium Sm 2% HNO 3 Sm 2 O 3 N9300147 114<br />

Scandium Sc 2% HNO 3 Sc 2 O 3 N9300148 228<br />

Selenium Se 2% HNO 3 Se N9300149 101 N9300182 50<br />

Silicon Si H 2 O (NH 4 )2SiF 6 N9300150 114 N9303799 50<br />

Silver Ag 2% HNO 3 Ag N9300151 101 N9300171 50<br />

Sodium Na 2% HNO 3 Na 2 CO 3 N9300152 101 N9303785 50<br />

Strontium Sr 2% HNO 3 Sr(NO 3 ) 2 N9300153 101<br />

Sulfur S H 2 O (NH 4 ) 2 SO 4 N9300154 101<br />

Tantalum Ta H 2 O NH 4 TaF 6 N9300155 114<br />

Tellurium Te 5% HNO 3 Te N9300156 114<br />

Terbium Tb 2% HNO 3 Tb 4 O 7 N9300157 114<br />

Thallium Tl 2% HNO 3 TlNO 3 N9300158 101 N9300170 50<br />

Thulium Tm 2% HNO 3 Tm 2 O 3 N9300160 152<br />

Tin Sn 20% HCl Sn N9300161 152 N9303801 89<br />

Titanium Ti H 2 O (NH 4 ) 2 TiF 6 N9300162 114 N9303806 50<br />

Tungsten W H 3 O (NH 4 ) 2 WO 4 N9300163 114<br />

Vanadium V 2% HNO 3 NH 4 VO 3 N9300165 101<br />

Ytterbium Yb 2% HNO 3 Yb 2 O 3 N9300166 114<br />

Yttrium Y 2% HNO 3 Y 2 O 3 N9300167 114 N9303810 50<br />

Zinc Zn 2% HNO 3 Zn N9300168 101 N9300178 50<br />

Zirconium Zr 2% HNO 3 ZrO(NO 3 ) 2 N9300169 114 N9303812 50<br />

Standards Atomic Absorption<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

69


WinLab32 Software for AA<br />

Software for Atomic Absorption<br />

WinLab32 Software for AA<br />

Combines Ease of<br />

Use and Flexibility to<br />

Improve Productivity<br />

WinLab32 for AA redefines the software<br />

standard for high-performance atomic<br />

absorption instruments. Designed for<br />

the rigorous needs of today’s analytical<br />

laboratory, WinLab32 gives you all the<br />

flexibility and power you need in an easyto-use,<br />

easy-to-learn package. WinLab32<br />

for AA software provides you with tools and<br />

features needed to quickly start running<br />

samples your way. Only WinLab32 for AA<br />

combines flexibility and ease of use to bring<br />

a new level of productivity to your laboratory.<br />

A suite of task-oriented windows can be displayed.<br />

Key Features:<br />

■ Common look and feel with WinLab32 for ICP for<br />

easy cross-platform use<br />

■ Flexibility for the most demanding needs<br />

■ Extensive QC options ensure data quality<br />

■ Wizards, Multi-language Tool Tips and Tip of<br />

the Day make WinLab32 for AA easy to learn,<br />

easy to use<br />

■ Data Export allows selected data results to be<br />

transfered to a network computer<br />

■ Powerful Examine Transient Peaks accelerates<br />

method development<br />

■ Check sums and Windows ® 2000 security ensure<br />

integrity for regulatory requirements<br />

Easy to Learn and Use — By Design<br />

WinLab32 for AA was not simply<br />

designed by PerkinElmer’s team of<br />

applications experts, programmers and<br />

graphic designers, it was designed by<br />

laboratory managers and AA users from<br />

around the world. The result is software<br />

that you have to see in operation to fully<br />

appreciate just how easy it is to learn and<br />

use. A few of the highlights that make<br />

WinLab32 easy to learn and use include:<br />

■ Wizards<br />

■ Extensive checking<br />

■ Tip of the Day<br />

■ Tool Tips<br />

■ Status panels<br />

■ Automated shutdown<br />

■ Analysis List<br />

■ Context-sensitive Help<br />

Data Reprocessing allows you to change parameters<br />

and recalculate results.<br />

70


WinLab32 Software for AA<br />

Software for Atomic Absorption Analysis<br />

Maximize Productivity<br />

In addition to the numerous ease-of-use characteristics,<br />

WinLab32 has the features you need to enhance productivity<br />

in your laboratory.<br />

■ WinLab32 Offline allows you to create methods, enter sample information,<br />

review or reprocess data — all without interrupting the active analysis<br />

■ Recall Calibration or Initial Calibration Options in the Method Editor<br />

can be used to manually or automatically recall a calibration previously<br />

stored with the method, eliminating the need to reconstruct the curve<br />

prior to sample analysis<br />

■ Edit Calibration gives you complete control over the quality of your<br />

calibration curve before you proceed with QC and sample analysis<br />

■ Data Reprocessing allows you to change many method and sample<br />

information parameters after you have collected the data and to recalculate<br />

the results to determine if the changes are appropriate for your samples<br />

■ Priority Sample and Append to Analysis List allows you to add<br />

samples anytime without interrupting the current analysis<br />

Helping to Meet Regulated Laboratory Requirements<br />

Many laboratories must comply with a variety of regulations<br />

imposed upon them by government agencies or quality<br />

protocols. WinLab32 contains a number of features needed<br />

to help your laboratory meet the regulations, including<br />

21 CFR Part II.<br />

WinLab32 Makes it Easy to Work with Data<br />

Once you have performed analyses, you should be free to<br />

report, change, send, archive, move, or export your data in<br />

any way you wish without following someone else’s rigid<br />

protocols. WinLab32 provides a number of tools to help you<br />

work with your data.<br />

■ Data Reporting Wizard<br />

■ Data Export Wizard<br />

■ Archive and restore functions<br />

■ Maintenance functions<br />

WinLab32 includes a variety of ways to export data,<br />

including parameters such as peak profiles, sample<br />

concentrations, etc.<br />

Worldwide Support<br />

WinLab32 for AA is backed by the largest worldwide<br />

technical support network in the industry — just what<br />

you would expect from the leader in analytical<br />

instrumentation for more than 40 years.<br />

Description Part No. Each (€)<br />

WinLab32 Controller Assembly for AA N1010202 4787<br />

Includes computer, 17" flat panel monitor, and<br />

Software Assembly. Contact us for current<br />

models and specifications<br />

WinLab32 Software Assembly for AA N1010200 3059<br />

Includes CD, printer cable, and an IEEE-488<br />

computer interface<br />

WinLab32 Enhanced Security Software Add-on for AA N1010230 3035<br />

Requires WinLab32 Controller or Software Assembly<br />

Wizards make complex tasks easy.<br />

Data Reporting Wizard allows you to report your data<br />

in a variety of formats.<br />

www.perkinelmer.com/<strong>supplies</strong><br />

71


Just touch<br />

and go.<br />

There, that’s all the training you need.<br />

Walk up to the AAnalyst 200 and let the touch screen guide you through everything<br />

from setup to analysis. It practically tells you what to do—and in your own<br />

language. All instrument controls are right there on the screen, available at your<br />

fingertips. Even troubleshooting and repairs are easier, with quick-change parts<br />

you simply snap out and snap in. No service visit, no down time. As rugged and<br />

reliable as ever, our newest AAnalyst is a better way to do AA. Experience it for<br />

yourself. Talk to a PerkinElmer inorganic analysis specialist today.<br />

© 2005 PerkinElmer, Inc. 400012A<br />

800-762-4000 (U.S. and Canada)<br />

(+1) 203-925-4602<br />

www.perkinelmer.com


Elemental Analysis<br />

For over 35 years, PerkinElmer has been a leader in organic<br />

elemental analysis, providing customers with reliable instrumentation<br />

that is easy to use and delivers fast, accurate results.<br />

The PerkinElmer 2400 Series II Elemental Analyzers<br />

supply speed, precision, ease of use and proven<br />

performance to your lab, and are based on the<br />

classical organic analysis techniques of Pregl and<br />

Dumas. Flexibility is a key feature of the 2400 Series II,<br />

offering you multiple analysis options including Carbon,<br />

Hydrogen, Nitrogen, Sulfur and Oxygen (CHN or CHNS<br />

and O2 analysis.) Plus, the analyzers are backed by<br />

PerkinElmer’s legendary worldwide service and support.


Elemental Analysis<br />

QUICK-FIND INDEX Page #<br />

2400 Series II Analysis Mode 76<br />

Kits<br />

2400 Tubes & Reagent Kits 78<br />

Autoinjector Spares 81<br />

Cables 77<br />

Calibration Standards 80<br />

Fitting Spares 82<br />

Gas Regulators 77<br />

Printer Supplies 77<br />

Reagents 78<br />

Sample Capsules 80<br />

Sample Handling Accessories 80<br />

Tools 82<br />

Tubes 79<br />

Valve Spares 83<br />

PerkinElmer offers a wide selection of superior quality products designed to work with<br />

your PerkinElmer instruments. Our precision designed products deliver the peace of<br />

mind that comes from knowing that you’ll get the results you need.<br />

The Quick Find Index to the left will help you find products fast. For your convenience,<br />

products are alphabetized by category, sub-category, and family. There is also a more<br />

complete Alphabetical INDEX on page 429 and a Part Number INDEX on page 407.<br />

2400 Series II Analysis Mode Kits<br />

2400 Tubes and Reagent Kits<br />

The 2400 Series II offers multiple analysis options: CHN,<br />

CHNS or Oxygen mode. As a user, you may choose one or<br />

more options to meet your laboratories needs. Analysis<br />

Mode Kits supply all the necessary items to changeover<br />

to a different mode of operation. The optional Column<br />

Switching Accessory (CSA) makes switching to the<br />

Oxygen mode very convenient.<br />

Page 76<br />

Convenient Consumable Kits simplify ordering and eliminate<br />

waste. Kits contain the necessary tubes, reagents and<br />

capsules for a defined quantity of runs. Reordering is easy<br />

and predicting annual costs is straightforward.<br />

Page 78<br />

Reagents<br />

Every genuine PerkinElmer reagent is designed specifically<br />

for your PerkinElmer instrument and will assure consistent,<br />

accurate results. Their high quality has been demonstrated<br />

in PerkinElmer instruments all over the world, for a wide<br />

variety of applications.<br />

Page 78<br />

Tubes<br />

PerkinElmer tubes are composed of high purity fused<br />

quartz, with a low thermal expansion rate. This along with<br />

our stringent dimension specifications guarantees the<br />

integrity of your system. All tubes are pressure-tested to<br />

insure your safety.<br />

Page 79


The PerkinElmer 2410 Series II Nitrogen Analyzer measures<br />

the nitrogen and/or protein content in virtually any material<br />

by an advanced combustion process based upon the classical<br />

Dumas method.<br />

Used primarily in the food and agricultural area, the 2410<br />

Series II replaces the time-consuming, multi-stepped Kjeldahl<br />

method of analyzing feeds, grains, cereals, dairy products,<br />

fish, meats, fruits, nuts, fertilizers, plants, soils, and sediments.<br />

Additional application areas are in the polymer and<br />

petroleum industries.<br />

■ Sample sizes up to 500 mgs<br />

■ Analysis time


2400 Series II Analysis Kits<br />

Analysis Kits<br />

CHNS Analysis Kit<br />

Elemental Analysis 2400 Series II Analysis Kits<br />

2400 Instrument<br />

CHN Analysis Kit<br />

CHN Analysis Kit<br />

For automatic determination of carbon, hydrogen, and<br />

nitrogen in organic substances.<br />

Add this optional kit to simultaneously determine CHN<br />

with your PerkinElmer 2400 Series II Analyzer. The sample<br />

is combusted in an oxygen-rich environment at 925 °C. The<br />

resulting reaction products are converted to carbon dioxide,<br />

water, and nitrogen. All of the<br />

reaction products are then<br />

separated and detected.<br />

Kit includes:<br />

Part No.<br />

N2410506<br />

Each (€)<br />

5806<br />

Components Qty. Part No.<br />

2 g Bottle of Acetanilide 1 02401121<br />

Silver Gauze 2 N2410145<br />

Copper Diffusion Plug 1 N2411333<br />

CHN Kit for 2000 Runs 1 N2410683<br />

CHNS Analysis Kit<br />

For automatic determination of carbon, hydrogen, nitrogen,<br />

and sulfur in organic substances.<br />

Add this optional kit to simultaneously determine CHNS<br />

with your PerkinElmer 2400 Series II Analyzer. The sample<br />

is combusted in an oxygen-rich environment at 975 °C. The<br />

resulting reaction products are converted to carbon dioxide,<br />

water, nitrogen, and sulfur dioxide.<br />

All of the reaction products are then<br />

separated and detected.<br />

Kit includes:<br />

Part No.<br />

N2410507<br />

Each (€)<br />

2652<br />

Components<br />

Part No.<br />

10 g Bottle of Sulfamic Acid N2410501<br />

4 g Bottle of Cystine N2410324<br />

2 g Bottle of Acetanilide 02401121<br />

CHNS Kit for 500 Runs<br />

N2410682<br />

Oxygen Analysis Kit<br />

Oxygen Analysis Kit<br />

For automatic determination of oxygen in organic substances.<br />

Add this optional kit to use with your PerkinElmer 2400 for<br />

oxygen analysis. The sample is pyrolyzed in a hydrogen/<br />

helium mixture at 1000 °C. When the resulting reaction<br />

products which contain oxygen pass over platinized carbon,<br />

they are converted to carbon monoxide. The carbon<br />

monoxide and other gases pass through scrubbers,<br />

where interferences are removed, and<br />

the carbon monoxide is then separated Part No. Each (€)<br />

and determined.<br />

N2410513 4056<br />

Kit includes:<br />

Components<br />

Part No.<br />

Quartz Oxygen Pyrolysis Tube<br />

N2411235<br />

Quartz Reduction Tube<br />

N2411300<br />

10 g Bottle of Platinized Carbon 02400119<br />

Platinum Gauze Strip<br />

N2411273<br />

Oxygen Column<br />

N2420212<br />

Quartz Insert<br />

N2411401<br />

454 g Bottle of Copper Plus, Wire Form 02401362<br />

Scrubber Trap Assembly<br />

N2410189<br />

Acid Gas Scrubber Tube<br />

N2411359<br />

100 g Bottle of Colorcarb 02400115<br />

454 g Bottle of Magnesium Perchlorate 02401119<br />

Silver Gauze Strip<br />

N2410145<br />

4 g Bottle of Benzoic Acid 02401120<br />

Not included, but highly recommended for use<br />

with the Oxygen Analysis Kit (N2410513):<br />

Components Part No. Each (€)<br />

Column Switching Accessory N2410265 1441<br />

76


Cables<br />

Weight Transfer Cables<br />

For connection of AD-4 or AD-6<br />

to 2400/2410. (pkg. 1)<br />

Part No. Each (€)<br />

N2410174 261<br />

Laboratory Products<br />

For the 2400/2410 Series II Analyzers<br />

Pyrolysis Gas Regulator<br />

For high purity carrier gas (5% hydrogen in helium) used<br />

with the 2400 Oxygen Analysis mode. Dual stage, stainless<br />

steel diaphragm regulator for high<br />

precision and non-diffusibility. CGA<br />

350 fitting for connection to cylinder.<br />

Part No.<br />

N2410327<br />

Each (€)<br />

861<br />

For connection of TLB-40<br />

or TLB-60 to 2410.<br />

For connection of Mettler Toledo ®<br />

UMX2 ultramicrobalance to a new<br />

or updated 2400 Series II analyzer.<br />

For connection of Sartorius SE2<br />

ultramicrobalance to a new or<br />

updated 2400 Series II analyzer.<br />

Printer Cable<br />

For connection of dot matrix printer<br />

to 2400/2410. (pkg. 1)<br />

Computer Cable<br />

For connection of a PC to 2400.<br />

Gas Lines<br />

Product Part No. Each (€)<br />

Copper Gas Line Assembly (1/8"), Set of 2 Lines N2410170 217<br />

For carrier and combustion gases with the 2400<br />

Plastic Gas Line Assembly (1/4") N2410147 79<br />

For pneumatic gas with the 2400 and 2410<br />

For carrier and combustion gases with the 2410<br />

Gas Pressure Regulators<br />

Helium or Argon Gas Regulator<br />

For 2400 high purity carrier gas, dual stage, stainless steel<br />

diaphragm regulator for high precision<br />

and non-diffusibility. CGA 580 fitting<br />

for connection to cylinder.<br />

Part No.<br />

N2410172<br />

Each (€)<br />

861<br />

Oxygen Gas Regulator<br />

Part No.<br />

Each (€)<br />

04190226 200<br />

Part No.<br />

Part No.<br />

Each (€)<br />

N2410141 179<br />

Part No.<br />

Each (€)<br />

N2410360 73<br />

Part No.<br />

Each (€)<br />

N2410361 74<br />

Each (€)<br />

N2410365 22<br />

For 2400 and 2410 high purity gas, dual stage, stainless steel<br />

diaphragm regulator for high precision<br />

and non-diffusibility. CGA 540 fitting<br />

for connection to cylinder.<br />

Part No.<br />

02400084<br />

Each (€)<br />

606<br />

Pneumatic Gas Regulator<br />

For driving valves in the 2400 and 2410. Single stage, metal<br />

diaphragm regulator. CGA 590 fitting<br />

for connection to cylinder.<br />

Part No. Each (€)<br />

CO 2 Regulator with Warmer<br />

For high purity CO 2 carrier gas, dual stage, metal diaphragm<br />

regulator. Includes CO 2 warmer which requires an electrical<br />

connection. CGA 320 fitting for connection to cylinder.<br />

Voltage Part No. Each (€)<br />

120 V N2410502 1288<br />

230 V N2410503 1288<br />

Printer Kit and Supplies<br />

PE 2400 Series Printer Kit (100/120 V)<br />

For hard copy printout of 2400/2410<br />

data and diagnostics directly<br />

from instrument.<br />

Kit includes:<br />

Components<br />

Part No.<br />

Printer (100/120 V) 09421018<br />

Printer Accessory Kit<br />

N2410248<br />

Includes:<br />

Serial Interface Board 09421021<br />

Printer Paper (3200 sheets)<br />

N5001409<br />

Printer Cable<br />

N2410141<br />

Connects printer to 2400/2410 Analyzer<br />

PE 2400 Series Printer Kit (230 V)<br />

For hard copy printout of 2400/2410<br />

data and diagnostics directly<br />

from instrument.<br />

Kit includes:<br />

Components<br />

N2410173 504<br />

Part No.<br />

Part No.<br />

Printer (230 V) 09421019<br />

Printer Accessory Kit<br />

N2410248<br />

Includes:<br />

Serial Interface Board 09421021<br />

Printer Paper (3200 sheets)<br />

N5001409<br />

Printer Cable<br />

N2410141<br />

Connects printer to 2400/2410 Analyzer<br />

For Ultramicrobalance Supplies, please see Thermal Analysis Section.<br />

Each (€)<br />

N2410021 2079<br />

Part No.<br />

Each (€)<br />

N2410022 2092<br />

Laboratory Products Elemental Analysis<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

77


Packing Supplies<br />

Reagents, Tubes, and Receptacles<br />

2400 Tubes and Reagent Kits<br />

2400 CHN Combustion Tubes<br />

and Reagents for 2000 Runs<br />

Includes: combustion tubes, EA1000,<br />

silver tungstate on magnesium oxide,<br />

silver vanadate and vial receptacles.<br />

Part No. Each (€)<br />

N2410680 927<br />

Elemental Analysis Packing Supplies<br />

2400 CHN Reduction Tubes<br />

and Reagents for 500 Runs<br />

Includes: reduction tubes,<br />

Copper Plus, and copper oxide.<br />

2400 CHNS Combustion/Reduction Tubes<br />

and Reagents for 500 Runs<br />

Includes: combustion/reduction tubes,<br />

EA600, and copper (wire form).<br />

CHN Kit for 2000 Runs<br />

Includes: combustion and reduction<br />

tube and reagent kits and tin capsules.<br />

CHNS Kit for 2000 Runs<br />

Includes: combustion/reduction tube,<br />

reagent kits, and tin capsules.<br />

CHN Reduction Kit Part No. N2410681<br />

CHNS Combustion/Reduction Kit Part No. N2410682<br />

Part No.<br />

Each (€)<br />

N2410681 548<br />

Part No.<br />

Each (€)<br />

N2410682 2345<br />

Part No.<br />

Each (€)<br />

N2410683 5500<br />

Part No.<br />

Each (€)<br />

N2410684 8900<br />

CHN Combustion Kit Part No. N2410680<br />

Packing Supplies<br />

Product Part No. Each (€)<br />

Silver Gauze Strip, (pkg. 1) N2410145 87<br />

Platinum Gauze Strip, (pkg. 1) N2411273 740<br />

Quartz Wool, (50 g) 02401118 172<br />

Copper Diffusion Plug, (pkg. 1) N2411333 48<br />

Reagents<br />

Product Part No. Each (€)<br />

EA-1000, (50 g) N2410092 217<br />

EA-1000, (3 x 50 g) N2410166 536<br />

Silver Tungstate/Magnesium Oxide, (100 g) 02401344 536<br />

Silver Tungstate/Magnesium Oxide, (3 x 100 g) N2410165 1390<br />

Silver Vanadate, (40 g) 02401117 116<br />

Silver Vanadate, (3 x 40 g) N2410164 281<br />

EA-6000, (50 g) N2410278 269<br />

EA-6000, (5 x 50 g) N2410331 874<br />

Platinized Carbon, (10 g) 02400119 670<br />

Copper Plus, (454 g) 02400117 217<br />

Copper Plus, (10 x 454 g) N2410157 1492<br />

Copper Plus – Wire Form, (454 g) 02401362 236<br />

Copper Plus – Wire Form, (5 x 454 g) N2410332 874<br />

Copper for Nitrogen, (454 g) N2411527 115<br />

Copper for Nitrogen, (10 x 454 g) N2410518 944<br />

Copper Oxide – Wire Form, (454 g) 02401092 134<br />

Aquasorb (25 g) N2410277 77<br />

Colorcarb, (100 g) 02400115 107<br />

Colorcarb, (3 x 100 g) N2410188 395<br />

Magnesium Perchlorate, (454 g) 02401119 217<br />

Magnesium Perchlorate, (3 x 454 g) N2410191 395<br />

Thermolite, (100 g) 02400815 47<br />

78


Packing Supplies<br />

Reagents, Tubes, and Receptacles<br />

Receptacles<br />

Description Part No. Each (€)<br />

Quartz Tube Insert, (pkg. 1) N2411401 56<br />

Vial Receptacle<br />

For use with the 2400 in the CHN<br />

mode and with the 2410. pkg. 1<br />

Vial Receptacle<br />

For use with the 2400 in the CHNS and Oxygen modes.<br />

Recommended in CHN mode when a large amount of<br />

inert material will be left after the organic material has<br />

combusted. pkg. 10<br />

Part No. Each<br />

Tubes<br />

Part No.<br />

Each (€)<br />

N2411335 56<br />

N2410177 370<br />

PerkinElmer tubes are composed of pure fused quartz which<br />

is 99% SiO 2 . Fused quartz has been chosen because of its<br />

very high purity and low thermal expansion rate. Because<br />

we care about your safety, all combustion tubes are pressuretested<br />

to eliminate any tubes which might contain weak<br />

spots. In addition, stringent specifications are used to ensure<br />

that the combustion tubes fit in an airtight connection when<br />

placed in the analyzer.<br />

Type Material Analyzer Mode Qty. Part No. Each (€)<br />

Combustion Quartz 2400 CHN 1 N2411264 185<br />

Combustion Quartz 2400 CHN 3 N2410212 453<br />

Combustion Quartz 2400 CHN 10 N2410153 1301<br />

Combustion/ Quartz 2400 CHNS 1 N2411514 185<br />

Reduction<br />

Combustion/ Quartz 2400 CHNS 5 N2410330 733<br />

Reduction<br />

Combustion Stainless 2410 Nitrogen 1 N2421070 79<br />

or Reduction Steel<br />

Combustion Quartz 2410 Nitrogen 1 N2411487 93<br />

Pyrolysis Quartz 2400 Oxygen 1 N2411235 172<br />

Reduction Quartz 2400 Oxygen 1 N2411300 77<br />

& Sulfur<br />

Reduction Quartz 2400 CHN 1 N2411291 159<br />

Reduction Quartz 2400 CHN 10 N2410154 1269<br />

Scrubber Pyrex ® 2400/ Oxygen 1 N2411359 140<br />

2410 & Nitrogen<br />

(€)<br />

Combustion and Pyrolysis Tubes<br />

Reduction Tubes<br />

Packing Supplies Elemental Analysis<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

79


Sample Handling<br />

Calibration Standards, Capsules, and Supplies<br />

Calibration Standards<br />

Sample Capsules<br />

Elemental Analysis Sample Handling<br />

80<br />

Before using your elemental analyzer to analyze unknown<br />

materials, you must calibrate it. Combustion standards burn<br />

readily, and their known composition of carbon, hydrogen,<br />

nitrogen, oxygen, and sulfur can be used to calibrate your<br />

elemental analyzer.<br />

The PerkinElmer Combustion Standards are stable materials<br />

which are not subject to ambient influences and are<br />

recommended for the PerkinElmer 2400/2410 and Model<br />

240 instruments.<br />

Acetanilide<br />

Is routinely used during the carbon, hydrogen, and nitrogen<br />

operation mode. The sample weight percentages of this<br />

compound are:<br />

Carbon = 71.09%<br />

Hydrogen = 6.71%<br />

Nitrogen = 10.36%<br />

Benzoic Acid<br />

Is used as the combustion standard with the Oxygen<br />

Analysis Kit. The sample weight percentages of this<br />

compound are:<br />

Carbon = 68.85%<br />

Hydrogen = 4.95%<br />

Nitrogen = 0.0%<br />

Oxygen = 26.20%<br />

Cyclohexanone 2, 4 Dinitrophenylhydrazone<br />

Is another recommended standard for CHN analysis.<br />

This compound contains:<br />

Carbon = 51.19%<br />

Hydrogen = 5.07%<br />

Nitrogen = 20.14%<br />

Cystine<br />

Is a standard which is used for sulfur determination.<br />

Its composition is:<br />

Carbon = 29.99%<br />

Hydrogen = 5.03%<br />

Nitrogen = 11.66%<br />

Sulfur = 26.69%<br />

EDTA<br />

Is a standard used routinely for nitrogen analysis<br />

with the PerkinElmer 2410. Its composition is:<br />

Nitrogen = 9.59%<br />

Sulfamic Acid<br />

Is used to condition a new<br />

CHNS analysis tube.<br />

Qty. Part No. Each (€)<br />

2 g 02401121 210<br />

Qty. Part No. Each (€)<br />

4 g 02401120 82<br />

Qty. Part No. Each (€)<br />

1 g 02401347 110<br />

Qty. Part No. Each (€)<br />

4 g N2410324 196<br />

Qty. Part No. Each (€)<br />

100 g N2410325 77<br />

Qty. Part No. Each (€)<br />

10 g N2410501 62<br />

Product Qty. (pkg.) Part No. Each (€)<br />

Tin Capsules<br />

For analysis of nonvolatile solid samples.<br />

Standard Tin Capsule Kit 96 N2411255 102<br />

96 (10 pkgs.) N2410155 861<br />

Large Tin Capsule Kit 250 N2411362 116<br />

Flat Tin Disks<br />

For analyzing 13 or 25 mm filters.<br />

Flat Tin Disks 100 N2411363 98<br />

100 (10 pkgs.) N2410244 797<br />

Aluminum Capsules<br />

For analyzing volatile liquid samples. Requires, but does<br />

not include: Liquid Sample Sealer (B0198093) and Tin<br />

Capsules (N2411255, N2410155, or N2411362).<br />

Aluminum Capsules, 4 μL 1000 02400642 236<br />

Aluminum Capsules, 30 μL 1000 00090709 268<br />

Tin Pans and Covers<br />

For volatile liquid or solid samples, including viscous<br />

materials. Requires, but does not include: Volatile Sample<br />

Sealer (02190061).<br />

Volatile Tin Sample Pans and Covers 400 N2410320 606<br />

Silver Capsules<br />

For analyzing organic substances with Oxygen Analysis.<br />

Silver Capsules 96 N2411364 198<br />

Sample Handling Accessories<br />

Sample Handling Kit<br />

Kit includes:<br />

Description<br />

Part No.<br />

One Hayman Microspatula 02401286<br />

Five Brushes 02401296<br />

One Hook Tweezers 09908138<br />

One Flat Forceps 09908400<br />

One Pedestal for Sample Capsule<br />

N2411267<br />

Sealers<br />

Liquid Sample Sealer<br />

For use with volatile, nonviscous, noncorrosive samples.<br />

Tin/Aluminum Capsules must be ordered separately. Kit<br />

includes: one Capsule Sealing Unit,<br />

one Magazine for 4 and 30 μL Capsules,<br />

and one Instruction Manual.<br />

Part No.<br />

B0198093<br />

Each (€)<br />

1090<br />

Volatile Sample Sealer<br />

For use with volatile, viscous,<br />

noncorrosive samples.<br />

Part No.<br />

Each (€)<br />

N2410146 325<br />

Part No.<br />

Each (€)<br />

02190061 1528


Spare Parts and Tools<br />

Autoinjector and Fitting Spares<br />

Autoinjector Spares<br />

O-Ring, Auto-Injector RAM<br />

Description Part No. Each (€)<br />

For use with 2400 (pkg. 1) 09902048 9<br />

For use with 2410 (pkg. 1) 09902035 3<br />

Spring, Auto-Injector RAM<br />

For use with the 2400 and 2410.<br />

(pkg. 1)<br />

O-Ring, Sample Drop Valve<br />

For use with the 2400 and 2410.<br />

Fittings for Combustion<br />

and Reduction Tubes<br />

Part No.<br />

Each (€)<br />

09920404 3<br />

Part No.<br />

Each (€)<br />

09902123 17<br />

A variety of hardware fittings are required to connect the<br />

glassware to your PerkinElmer Elemental Analyzer. The<br />

nuts, washers, O-Rings, and other fittings listed here are<br />

identical to the parts which were shipped with your<br />

instrument. Use them as replacement parts to ensure<br />

perfect connections.<br />

Components Part No. Each (€)<br />

1 Filter Disk, 11 mm, (pkg. 12) 02400137 48<br />

For use with Crossover Fitting<br />

Bracket Assembly (N2410315)<br />

Filter Disk, 25 mm, (pkg. 12) N2410237 77<br />

For use with Crossover Fitting<br />

Bracket Assembly (N2420214)<br />

2 O-Ring, 25 mm Silicone, (pkg. 1) 09902188 2<br />

3 For use with the<br />

2400 Combustion Tube3<br />

2 O-Ring, 25 mm Viton ® , (pkg. 1) 09902048 9<br />

3 For use with the 2410 Combustion<br />

and Reduction Tube<br />

3<br />

3 Glass Tube Washer, 25 mm, (pkg. 1) N2411118 9<br />

4 Glass Tube Nut, 25 mm, (pkg. 1) N2411117 56<br />

5 25 mm Combustion Tube Ceramic N2411341 38<br />

Ring, (pkg. 1)<br />

6 O-Ring, 11 mm Viton, (pkg. 12) 02401583 14<br />

7 Glass Tube Washer, 11 mm, (pkg. 1) 02401042 5<br />

8 Glass Tube Nut, 11 mm, (pkg. 1) 02401028 28<br />

9 11 mm Reduction Tube Ceramic Ring, N2411342 38<br />

10 (pkg. 1)<br />

10<br />

Crossover Fitting Bracket Assembly<br />

For use with 2400 (pkg. 1) N2410315 798<br />

For use with 2410 (pkg. 1) N2420214 363<br />

1<br />

2<br />

6<br />

7<br />

3<br />

8<br />

4<br />

9<br />

5<br />

Reduction Chamber<br />

Combustion Chamber<br />

8<br />

7<br />

8<br />

6<br />

7<br />

1<br />

6<br />

1<br />

10<br />

PerkinElmer 2400 CHNS/O Combustion and Reduction Tube Connections<br />

Spare Parts and Tools Elemental Analysis<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

81


Spare Parts and Tools<br />

Fittings and Tools<br />

Fittings for Scrubber<br />

Spare Parts for 2400/2410<br />

Elemental Analysis Spare Parts and Tools<br />

1<br />

6<br />

7<br />

8<br />

11<br />

Components Part No. Each (€) Description Part No. Each (€)<br />

Filter Disk, 11 mm, (pkg. 12) 02400137 48<br />

For use with bottom end of<br />

Scrubber Tube (N2411359)<br />

O-Ring, 11 mm Viton, (pkg. 12) 02401583 14<br />

Glass Tube Washer, 11 mm, (pkg. 1) 02401042 5<br />

Glass Tube Nut, 11 mm, (pkg. 1) 02401028 28<br />

Scrubber Tube N2411359 140<br />

For use with 2400 in oxygen analysis<br />

mode as an acid-gas scrubber<br />

For use with 2410 in nitrogen as a<br />

water scrubber<br />

11<br />

8<br />

8<br />

6<br />

7<br />

6<br />

7<br />

1<br />

Upper<br />

Movable<br />

Bracket<br />

PerkinElmer 2400 CHNS/O<br />

Acid-Gas Scrubber Connections<br />

Solenoid In-line Filter Assembly 09903665 56<br />

Solenoid In-line Filter (pkg. 1) 09903673 36<br />

Replacement 10 Micron Filter for (09903665)<br />

Pneumatic Valve N2411019 236<br />

Tools<br />

Product Part No. Each (€)<br />

25 mm Tube Wrench for the 2400/2410 N2411144 21<br />

11 mm Tube Wrench for the 2400/2410 09907204 48<br />

Spanner Wrench for the Normally Open 02401294 10<br />

and Normally Closed Valves<br />

Retrieving Wire for the 2400/2410 N2411274 48<br />

Receptacle Removal<br />

82


Spare Parts and Tools<br />

Valve Spares<br />

Valve Spares<br />

Your elemental analyzer contains several valves that control<br />

the flow of gases which combust your sample and carry it<br />

through the instrument. The valves labeled A, B, D, E, F,<br />

and H are Normally Closed Valves. When rebuilding a<br />

Normally Closed Valve, you should replace the Plunger<br />

(N2411257), Plunger Spring (02401291), and the O-Ring<br />

(02401293). The D and E valves in the Effluent Manifold,<br />

direct the sample gas into the mixing volume portion of the<br />

system. These two valves contain an In-Line Filter<br />

Assembly (09903665), to filter residue or dirt particles<br />

which could affect the valves’ efficiency. The 10-micron<br />

filter (09903673) inside the filter assembly will require<br />

periodic replacement. On the Normally Open C Valve, the<br />

Plunger (02402087), Plunger Spring (N2411374), O-Ring<br />

(02401293), and Adapter Seal (02402089) must be replaced.<br />

To keep your instrument operating efficiently, you should<br />

clean and rebuild valves every year. Certain other parts, too,<br />

will require periodic replacement. The parts offered here can<br />

all be replaced without the assistance of a service engineer.<br />

They are all identical to the parts which were originally<br />

supplied with your analyzer. Instructions for replacing<br />

these parts are included in your operator’s manual.<br />

Normally Closed Valve Assembly<br />

2<br />

1<br />

3<br />

Components Part No. Each (€)<br />

Valve Plunger Spring 02401291 9<br />

Valve Plunger N2411257 38<br />

Valve O-Ring 02401293 9<br />

Normally Open Valve Assembly<br />

6<br />

4<br />

5<br />

3<br />

Part No.<br />

Each (€)<br />

N2411087 172<br />

Part No.<br />

Each (€)<br />

N2411088 230<br />

Components Part No. Each (€)<br />

Valve O-Ring Adapter 02402089 9<br />

Valve Plunger 02402087 65<br />

Valve Plunger Spring N2411374 14<br />

Valve O-Ring 02401293 9<br />

1<br />

3<br />

2<br />

Normally Closed Valve<br />

Part No. N2411087<br />

4<br />

3<br />

5<br />

Normally Open Valve<br />

Part No. N2411088<br />

6<br />

Spare Parts and Tools Elemental Analysis<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

83


Whichever piece of the planet<br />

you’re monitoring, we can help.<br />

PerkinElmer’s global environmental<br />

expertise goes beyond instruments,<br />

software and laboratory information<br />

management systems. Whether your<br />

analyses require organic or inorganic<br />

methods, PerkinElmer has the products—<br />

and the people—to help your lab achieve<br />

greater productivity, efficiency and compliance<br />

with complex regulations.<br />

We incorporate the planet’s best practices<br />

into our products and impart them to<br />

you with our knowledgeable support.<br />

And with over 1,000 factory-trained<br />

professionals worldwide, we provide<br />

rapid service response to maximize<br />

uptime. So no matter what you analyze,<br />

if you want to do it better, smarter and<br />

faster, contact PerkinElmer.<br />

© 2005 PerkinElmer, Inc. 400056_01<br />

800-762-4000 (U.S. and Canada)<br />

(+1) 203-925-4602<br />

For a complete listing of our global offices, visit: www.perkinelmer.com/lasoffices<br />

www.perkinelmer.com


PerkinElmer continues to drive innovation<br />

and performance in Gas Chromatography<br />

(GC) instrumentation and software, with<br />

a strong focus on making your lab more<br />

productive. Backed by our worldwide,<br />

world-class service and support team,<br />

PerkinElmer GC products are a great fit<br />

for your modern, fast-paced lab.<br />

PerkinElmer is the only GC supplier<br />

that manufactures and sells a complete<br />

single-vendor solution – from sample<br />

handling to data handling. This means<br />

you will not struggle to find answers to<br />

applications and service questions – one<br />

company provides the complete solution.<br />

Gas Chromatography


Gas Chromatography<br />

QUICK-FIND INDEX Page #<br />

Autosampler Accessories<br />

Vials, Caps and Septa 89<br />

Autosampler Syringes 88<br />

Capillary Columns Accessories 92<br />

Capillary Columns 91<br />

Capillary Injectors 150<br />

Detectors 131<br />

Ferrules 94<br />

Gas Purification Systems 164<br />

Gas Sampling Supplies 163<br />

Headspace Accessories<br />

and Supplies 143<br />

Filters and Traps 163<br />

Headspace Vials, Caps,<br />

and Septa 148<br />

Hydrogen Generators 165<br />

Injector Liners 157<br />

PerkinElmer offers a wide selection of superior quality products designed to work with<br />

your PerkinElmer instruments. Our precision-designed products deliver the peace of<br />

mind that comes from knowing that you’ll get the results you need.<br />

The Quick Find Index to the left will help you find products fast. For your convenience,<br />

products are alphabetized by category, sub-category, and family. There is also a more<br />

complete Alphabetical INDEX on page 429 and a Part Number INDEX on page 407.<br />

Headspace Vials, Caps, and Septa<br />

PerkinElmer’s patented vial and cap design incorporates<br />

pressure relief features which guarantee safe operation with<br />

the high pressure typically developed during thermostatting.<br />

These vials have a greater wall thickness and round base<br />

which enables them to withstand pressure up to 60 psig.<br />

PerkinElmer septa are designed for the patented pressure<br />

release cap to ensure safe operation at higher temperatures. Available pre-assembled<br />

into caps with starsprings.<br />

Page 148<br />

Capillary Columns<br />

We use only the finest quality of high-strength fused silica in<br />

the manufacture of our columns. Each column is individually<br />

inspected and tested to guarantee you the highest<br />

performance and to maximize reproducibility.<br />

Page 91<br />

Injector Septa 159<br />

Ozone Precursor 180<br />

PerkinElmer TotalChrom<br />

Software 173<br />

Swagelok Fittings 95<br />

Syringes 161<br />

Thermal Desorber Stainless<br />

Steel and Glass Tubes 181<br />

Thermal Desorber Traps<br />

and Fittings 182<br />

Valves 168<br />

Vial Crimping Tools 90<br />

Syringes<br />

PerkinElmer Injector Syringes have been tested and<br />

optimized for use with a 7 cm needle. This is critical for<br />

depositing sample in the optimal zone. Syringes are<br />

individually inspected for accuracy and performance.<br />

Syringes for 0.5 μL to 50 μL capacity in two different point<br />

styles are available. PerkinElmer ultra micro volume syringes are recommended for<br />

sample injection of less than 5 μL.<br />

Page 161<br />

Hydrogen Generators<br />

The patented DBS PG-H 2 series of Hydrogen Pure Gas<br />

Generators is ideal for operation with gas analyzers as a<br />

source of pure hydrogen in plasma chambers and other<br />

isolated environments. Electrolytic membrane technology<br />

is preferred over alternative hydrogen generating techniques<br />

because it is clean, requires less maintenance, and there is<br />

no need to store chemicals to maintain operation.<br />

Page 165


Clarus GC<br />

Sleek design and easy touch screen<br />

revolutionize GC interaction<br />

Gas chromatography started in 1952, with the seminal work of A.J.P.<br />

Martin and A.T. James and, within a few years, it became one of the<br />

most popular analytical techniques. PerkinElmer played a crucial role in<br />

the development of the technique:<br />

Clarus 500 GC<br />

■ Dual-channel, real-time signal display<br />

on the touch screen<br />

■ Flexible configurations with<br />

integrated mass spectrometry,<br />

headspace or thermal desorption<br />

and pyrolysis samplers<br />

■ Temperature-programmable inlets<br />

maximize reproducibility<br />

■ Pneumatic Pressure Controllers (PPC)<br />

provide accurate and highly<br />

reproducible gas controls<br />

■ GC analysis at your fingertips<br />

■ Easy setup/method development<br />

■ Multiple-language support<br />

■ Enhanced Solvent Purge mode<br />

■ Isolation mode<br />

■ High-pressure pulse injection<br />

■ Large-volume injection<br />

■ Petrochemical analysis from Hydrogen<br />

to Asphalt<br />

■ Ozone Precursors analysis<br />

■ Air Toxics analysis<br />

■ Food and Beverage quality control<br />

The sleek Clarus ® Gas Chromatograph<br />

from PerkinElmer offers a whole new<br />

approach to the way you interact with<br />

your GC instrument. An intuitive touchscreen<br />

interface features real-time signal<br />

display and eight-language support.<br />

Available in hundreds of configurations<br />

ranging from dedicated analyzers for<br />

petrochemical and air analysis to powerful<br />

mass spectrometer units, the Clarus GC is<br />

extremely flexible. For applications<br />

requiring mass spectrometer detection,<br />

the Clarus GC can be coupled to the<br />

industry’s easiest-to-use and widestmass-range<br />

quadrupole mass spectrometer.<br />

The Clarus GC features the PerkinElmerexclusive<br />

PreVent operating mode. This<br />

powerful mode uses the combined<br />

features of the temperatureprogrammable<br />

PSS injector and the PPC,<br />

to increase analytical throughput, manage<br />

difficult samples, protect the column and<br />

chromatograph and lower detection limits<br />

PerkinElmer’s award-winning datahandling<br />

software makes managing<br />

data easier than ever.<br />

Combine the Clarus GC with the Clarus<br />

Mass Spectrometer (MS), market-leading<br />

PerkinElmer TurboMatrix samplehandling<br />

accessories, flexible user-friendly<br />

TotalChrom ® software and world-class<br />

service and support for an integrated,<br />

complete analytical solution.<br />

The totally integrated Clarus autosampler<br />

provides flexibility and automation<br />

capability for the gas chromatograph.<br />

The autosampler accommodates three<br />

autosampler syringe sizes (0.5, 5.0, and<br />

50 μL) and three injection speeds (slow,<br />

normal, and fast), for complete application<br />

flexibility. Unobstructed access to either<br />

injection port with one autosampler<br />

permits any combination of analyses<br />

for the most efficient utilization of<br />

the gas chromatograph.<br />

The Clarus MS features a wealth of<br />

innovative technology to provide the most<br />

complete characterization of samples.<br />

PerkinElmer Selected Ion and Full Ion<br />

(SIFI) scanning technology and high<br />

scan speeds increase system accuracy.<br />

The mass spectrometer boasts a fast<br />

scanning speed with the widest mass<br />

range available for GC/MS, providing<br />

capability to analyze a greater scope<br />

of applications.<br />

The combination of a Clarus GC with a<br />

data-handling system provides a total<br />

laboratory solution from data collection<br />

and analysis to reporting and storage.<br />

87


Autosampler Accessories<br />

Syringes and Accessories<br />

Autosampler Replacement Parts<br />

Description Part No. Each (€)<br />

Gas Chromatography Autosampler Accessories<br />

1 Replacement Vial Locator (may require N6101182 14<br />

service installation, not included)<br />

2 Spring (pkg. 1)* N6101183 4<br />

3 Shoulder Screw (pkg. 1)* 09907998 3<br />

* Requires two for complete installation. See illustration.<br />

Miscellaneous Accessories<br />

Autosampler Starter Kit<br />

Includes: 5 μL x 0.63 mm o.d. syringe, 2 mL clear sample<br />

vials (100), 2 mL amber sample vials (100), blue crimp<br />

caps with septa (100), green crimp caps with septa (100),<br />

red crimp caps with septa (100), septa for waste/wash<br />

vials (100), crimper – 11 mm,<br />

decapper – 11 mm, 2 mL vial rack. Part No. Each<br />

Autosampler Thermostatting Accessory<br />

Allows thermostatting of Autosampler tray from 10 to 50 °C.<br />

Accessory includes: tubing, tie wraps,<br />

clamp, and instructions.<br />

(Circulating bath not included.)<br />

Part No.<br />

N6120036<br />

Each (€)<br />

286<br />

AutoSystem XL Autosampler<br />

Add-On Accessory (White Color)<br />

Note: Cannot be installed on an AutoSystem.<br />

Service installation is required.<br />

Spare Autosampler Tray<br />

1<br />

3<br />

2<br />

N6120105 791<br />

Part No.<br />

Each (€)<br />

N6120181 10000<br />

Part No.<br />

(€)<br />

Each (€)<br />

N6120031 287<br />

5 μL Syringe for Autosampler Part No. N6101390<br />

Syringes<br />

Replacement Needles for 0.5 μL Syringes<br />

0.5 μL Syringes<br />

Needle o.d. Part No. Each (€)<br />

0.47 N6101470 74<br />

0.63 N6101469 74<br />

Recommended Use Needle o.d. Part No. Each (€)<br />

Low injection volume. 0.53 capillary 0.47 N6101253 210<br />

on-column injection. Plunger type: Metal<br />

Plunger in needle type<br />

Low injection volume analyses 0.63 N6101252 210<br />

Plunger type: Metal<br />

Plunger in needle type<br />

5 μL Syringes<br />

Recommended Use Needle o.d. Part No. Each (€)<br />

0.53 capillary on-column injection 0.47 N6101380 113<br />

Plunger type: metal. Plunger in barrel<br />

Routine analyses. Plunger type: metal 0.63 N6101251 110<br />

Plunger in barrel<br />

Routine analyses. Shipped standard 0.63 N6101390** 110<br />

with instrument. Plunger type: metal<br />

Plunger in barrel with Teflon ® -tipped seal<br />

** Shipped standard with instrument<br />

50 μL Syringe<br />

Recommended Use Needle o.d. Part No. Each (€)<br />

Metal plunger in barrel type 0.47 N9302799 223<br />

Metal plunger in barrel type 0.63 N6101760 200<br />

88


Autosampler Accessories<br />

Vials, Caps, and Septa<br />

Crimp Caps and Septa<br />

Screw Top Sample Vials and Caps<br />

Crimp Caps<br />

Aluminum crimp caps and<br />

septa for 11 mm sample vial,<br />

Teflon ® /rubber.<br />

Description Part No. Each (€)<br />

Blue Crimp Caps and Septa (pkg. 100) N9302686 41<br />

Green Crimp Caps and Septa (pkg. 100) N9302684 35<br />

Red Crimp Caps and Septa (pkg. 100) N9302685 37<br />

Silver Crimp Caps and Septa (pkg. 100) N9306015 25<br />

Viton ® Septa Crimp Caps<br />

These Viton septa caps are recommended for applications<br />

that require work with chloroform.<br />

Part No. Each (€)<br />

Crimp Top Sample Vials<br />

Amber (11 mm) vial for photosensitive samples,<br />

2 mL volume. Caps and septa not included.<br />

Low-Volume Sample Inserts<br />

N9302784 1035<br />

Part No.<br />

200 μL low volume glass inserts for crimp cap sample vials.<br />

Supports required but not included.<br />

Description Part No. Each (€)<br />

Insert (pkg. 1000) N9302681 471<br />

Support (pkg. 500) N9302682 77<br />

Clear (11 mm) sample<br />

vial, 2 mL volume.<br />

Caps and septa not<br />

included. (pkg. 100)<br />

Each (€)<br />

N9302680 31<br />

Part No.<br />

Each (€)<br />

N9301385 18<br />

These vials are custom designed for the AutoSystem Series<br />

and Clarus GC. (Not to be used with low-volume insert.)<br />

Description Part No. Each (€)<br />

Cap, for Screw Top Vial (pkg. 100) N9303441 10<br />

Septa for Screw Top Cap (pkg. 100) N9303442 22<br />

PTFE-Coated Butyl Rubber<br />

Vial, Clear Glass Screw Top (pkg. 100) N9302945 41<br />

Vial Holder Racks<br />

Keep your samples organized and tip proof! These rugged,<br />

plastic vial racks are great for holding vials while you load<br />

and cap your samples. They stack away neatly when done.<br />

Description Part No. Each (€)<br />

36 vial capacity, 20 mm N9301304 33<br />

50 vial capacity, 11 mm N9301303 33<br />

Waste Vials<br />

Description Part No. Each (€)<br />

Cap for Waste and Wash Vials (15 mm), (pkg. 1) 09923032 1<br />

Clear Waste and Wash Vial 4 mL (15 mm), (pkg. 1) 09923031 1<br />

Septa for Waste Wash Vials N9302780 37<br />

For use with viscous or toxic samples<br />

Diffusers for Waste and Wash Vials<br />

Diffusers are sold exclusively by PerkinElmer. The conical<br />

shape allows the needle to penetrate into solvent or waste.<br />

Reduces spillage and large losses<br />

through evaporation.<br />

Part No. Each (€)<br />

N6101276 1<br />

Autosampler Accessories Gas Chromatography<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

89


Autosampler Accessories<br />

Vial Crimping Tools<br />

Crimping Tools<br />

Gas Chromatography Autosampler Accessories<br />

Benchtop Crimper Part No. N6621006<br />

Electronic Crimper Part No. N9302567 (120 V)<br />

Benchtop Crimper<br />

Sturdy, rugged stand will accept three size jaws.<br />

Jaws required but not included.<br />

Part No.<br />

Jaws for Benchtop Crimpers<br />

Description Part No. Each (€)<br />

AutoSystem GC Vials, 11 mm N6621008 391<br />

Headspace Vials, 20 mm N6621009 344<br />

Electronic Crimpers<br />

Electronic crimpers and decappers are easy to use and<br />

fully rechargeable. Ergonomically designed to alleviate<br />

the potential for Carpal Tunnel Syndrome and provide a<br />

consistent crimp pressure numerous times. The unit comes<br />

with a standard Black and Decker VersaPak ® Gold battery<br />

and charger, and will crimp several hundred vials on<br />

one charge. Crimping pressure is fully adjustable for<br />

precision control.<br />

Description Part No. Each (€)<br />

11 mm Electronic Crimper 120V N9302567<br />

11 mm Electronic Crimper 200V N9302568 700<br />

11 mm Electronic Crimper 230V N9302569 700<br />

11 mm Electronic Crimper 240V N9302570 700<br />

11 mm Electronic Decapper 120V N9302575<br />

11 mm Electronic Decapper 200V N9302576 700<br />

11 mm Electronic Decapper 230V N9302577 700<br />

11 mm Electronic Decapper 240V N9302578 700<br />

Electronic Crimper Replacement Battery N9302585 44<br />

Hand Crimpers<br />

Description Part No. Each (€)<br />

1.5 mL (AutoSystem GC sample vials), 11 mm 00090699 263<br />

6.0 mL and 20.0 mL (headspace vials), 20 mm N9302785 256<br />

Economy Cap Removal Tool<br />

Each (€)<br />

N6621006 1685<br />

Description Part No. Each (€)<br />

11 mm Autosampler Crimp Caps N9301390 64<br />

20 mm Headspace Crimp Caps N9301270 64<br />

90


Capillary Columns<br />

Capillary Columns<br />

Capillary Columns<br />

Top 10 Reasons to Buy<br />

PerkinElmer Elite Series<br />

Capillary Columns<br />

1 Finest quality of high-strength fused silica<br />

2 Each column individually inspected and tested<br />

3 Reproducible results<br />

4 Crosslinked and bonded stationary phase<br />

5 Robust column cage<br />

6 Superior resolution<br />

7 Wide selection of stationary phases available<br />

8 Reduced baseline bleed<br />

9 Lower baseline noise<br />

10 Column lengths from 5 to 105 m<br />

Why choose fused silica?<br />

Many factors influence the quality<br />

of a column. Fused silica is considered<br />

to be the purest form of glass, with fewer<br />

metal oxides (Lewis acid sites) and<br />

hydrogen bonding (surface silanol)<br />

groups. The stationary phase is cross<br />

linked (polymerized) and also bonded<br />

to the surface of the column to provide<br />

a high degree of stability, resulting in<br />

lower bleeding of the stationary phase<br />

at elevated temperatures. The superior<br />

inertness of the column means that<br />

acidic and basic compounds can be<br />

analyzed on the same column.<br />

Selecting the right stationary phase<br />

The inherent efficiency (large number<br />

of theoretical plates) of capillary columns<br />

allows you to choose from relatively few<br />

types of phases, compared to the many<br />

varieties of packed columns previously<br />

required. Perhaps more importantly,<br />

because capillary columns are more<br />

efficient, you will see superior resolution<br />

resulting in narrower, taller peaks that<br />

allow easier integration from your data<br />

system. Identification of small peaks are<br />

facilitated by a reduced baseline bleed<br />

and lower baseline noise. Non-polar<br />

Elite-1 columns from PerkinElmer will<br />

preferentially retain non-polar<br />

compounds, whereas the PerkinElmer<br />

Elite-200 column phase provides<br />

high selectivity for analytes containing<br />

lone pair electrons, such as nitro and<br />

carbonyl groups. Elite-WAX polyethylene<br />

glycol columns are highly selective<br />

toward polar compounds such as alcohols.<br />

What length do I need?<br />

Typically, capillary columns are available<br />

in lengths from 5 to 105 meters. The<br />

longer the column the more resolving<br />

power, but this also increases the analysis<br />

time. Doubling a column length only<br />

increases resolution by approximately<br />

40% but, under isothermal conditions,<br />

will double the analysis time. If using<br />

a temperature programmed analysis,<br />

retention times are more dependent on<br />

the temperature than on the column<br />

length. PerkinElmer provides columns<br />

in the most popular lengths of 5, 10, 12,<br />

15, 25, 30, 50, 60, 75, 100, and 105 m<br />

depending upon the column i.d.<br />

91


Capillary Column Accessories<br />

Adapter Kits<br />

Gas Chromatography Capillary Column Accessories<br />

Adapter Kit Accessories<br />

Detector Receiver<br />

1/8 to 1/16 in. detector receiver for<br />

use when using capillary columns<br />

with FID, ECD, NPD, and FPD.<br />

Flow Accessory 0-20 mL<br />

For use when converting an<br />

AutoSystem flow controller<br />

to low-flow operation.<br />

Flow Accessory 0-100 mL<br />

Shipped as standard with instrument.<br />

Injector/Detector Adapter for<br />

Fused-Silica Capillary Columns<br />

This 1/8 to 1/16 in. stainless steel<br />

reducer can be easily installed. For<br />

use when installing capillary columns<br />

on the 1/8 in. split/splitless injector<br />

and all 1/8 in. detector fittings. The<br />

reducer allows the use of 1/16 in. graphite/vespel ferrules<br />

rather than the larger 1/8 in. ferrule.<br />

(Not compatible with AutoSystem<br />

Part No. Each (€)<br />

or Clarus Series.)<br />

N9300063 130<br />

Wafer Scribe<br />

The ceramic wafer scribe is inexpensive and ideal for<br />

cutting polyimide fused-silica capillary columns. The scribe<br />

is easy to hold and simple to use.<br />

All four sides can be used. (pkg. 10) Part No. Each (€)<br />

Wide-Bore Adapter Kit<br />

AutoSystem GC Adapter Kit<br />

Part No.<br />

Each (€)<br />

N6120020 69<br />

Part No.<br />

Each (€)<br />

N6101377 261<br />

Part No.<br />

Each (€)<br />

N6102190 185<br />

N9301376 59<br />

The 0.53 mm Capillary Column<br />

Adapter Kit from PerkinElmer<br />

contains all the parts necessary to<br />

adapt packed column injectors<br />

quickly and easily for use with<br />

wide-bore capillary columns. For accurate control of the<br />

low flows used in wide-bore capillary columns (down to<br />

1 mL/min.). Kit includes 0-20 mL/min. flow controller<br />

element, wide-bore adapter with 1/16 in. fitting, wide-bore<br />

glass liner and column support hanger. May be used in both<br />

on-column or off-column modes.<br />

(For AutoSystem GC Series only.) Part No. Each (€)<br />

N6120001 523<br />

Wide-Bore Kit<br />

Replacement Parts<br />

Column Nut 1/16 in.<br />

Replacement 1/16 in. column nut.<br />

Connects capillary column to adapter.<br />

Graphite/Vespel 1/16 in. Ferrule<br />

1/16 in. x 0.8 mm i.d. For connecting<br />

capillary columns to adapter liner.<br />

Graphite/Vespel 1/4 in. Ferrule<br />

For installing adapter liner into injector.<br />

Graphite Ferrule<br />

Reverse ferrules used to connect 0.53 mm capillary columns<br />

to wide-bore adapter kit. 1/16 in. fitting. Reverse ferrule<br />

1/16 in. x 0.8 mm i.d. (pkg. 10)<br />

Part No. Each (€)<br />

Graphite/Vespel Ferrule<br />

Reverse ferrules used to connect 0.53 mm capillary columns<br />

to wide-bore adapter kit. 1/16 in. fitting. Reverse ferrule<br />

1/16 in. x 0.8 mm i.d. (pkg. 10)<br />

Part No. Each (€)<br />

Wide-Bore Quartz Liner<br />

AutoSystem GC wide-bore<br />

replacement quartz liner.<br />

Wide-Bore Glass Liner<br />

Replacement glass liner (untreated)<br />

for use with the wide-bore adapter<br />

kit (0.53 mm columns).<br />

Part No.<br />

Part No.<br />

Each (€)<br />

09903392 27<br />

Part No.<br />

Each (€)<br />

09920107 84<br />

Part No.<br />

Each (€)<br />

09903739 21<br />

09920141 59<br />

09920107 84<br />

Each (€)<br />

N6121003 32<br />

Part No.<br />

Each (€)<br />

N6101375 29<br />

92


Capillary Column Accessories<br />

Connectors and Supplies<br />

Column Connectors<br />

Union Connectors<br />

Column i.d. (mm) Qty. Part No. Each (€)<br />

0.25* pkg. 10 N9301167 63<br />

0.32* pkg. 10 N9301169 96<br />

pkg. 5 N9301170 129<br />

0.53* pkg. 10 N9301171 63<br />

pkg. 5 N9301172 24<br />

Reducing Connectors<br />

Column i.d. (mm) Qty. Part No. Each (€)<br />

0.32 to 0.25* pkg. 10 N9301338 129<br />

0.53 to 0.25* pkg. 10 N9301340 129<br />

0.53 to 0.32* pkg. 10 N9301342 63<br />

pkg. 5 N9301341 42<br />

* Note: These connectors are not recommended<br />

for use with aluminum-clad columns.<br />

Tools<br />

Pin Vise and Drill Bits<br />

For enlarging ferrule i.d. for capillary columns. Kit includes<br />

a double-ended pin vise and a set of<br />

12 drill bits, sizes No. 61 (0.99 mm)<br />

through No. 80 (0.343 mm).<br />

Part No.<br />

N9301346<br />

Each (€)<br />

51<br />

Pin Vise and Drill Bit Kit Part No. N9301346<br />

Uncoated Deactivated<br />

Fused-Silica Capillary Tubing<br />

High-quality, uncoated fusedsilica<br />

tubing is available in<br />

standard capillary sizes.<br />

Deactivated tubing is perfect for<br />

making guard columns and<br />

replacement Transfer Lines in HS<br />

and TD samplers retention gaps;<br />

available in 5 m lengths. Use our<br />

SPLITTERS and CONNECTORS<br />

to attach tubing to your<br />

polyimide-coated columns.<br />

Polyimide-Uncoated Deactivated Tubing<br />

Tube i.d. (mm) Length Part No. Each (€)<br />

0.10 5 m N9301355 114<br />

0.18 5 m N9301354 75<br />

0.25 5 m N9301356 37<br />

0.32 5 m N9301357 37<br />

0.53 5 m N9301358 63<br />

Capillary Column Support for PerkinElmer GCs<br />

Column supports delicate fused-silica columns<br />

in the proper oven location for optimum<br />

chromatographic performance.<br />

Description Part No. Each (€)<br />

AutoSystem Series/Clarus N6101070 51<br />

Universal Connectors<br />

Allows for fast, leak-free connections of fused-silica<br />

columns. The new fused-silica tapered design allows<br />

connection of any size column and it’s easy to use.<br />

(0.1 to 0.53 mm columns can be used.)<br />

Description Part No. Each (€)<br />

Polyimide Sealing Resin* (5 g) N9301343 39<br />

Universal Connector* (pkg. 5) N9302149 81<br />

Universal Y Splitter* (pkg. 1) N9303448 96<br />

* Note: These connectors are not recommended<br />

for use with aluminum-clad columns.<br />

Universal Connector<br />

Part No. N9302149<br />

Capillary Column Accessories Gas Chromatography<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

93


Capillary Column Accessories<br />

Ferrules<br />

Gas Chromatography Capillary Column Accessories<br />

Graphite and Vespel Ferrules<br />

Graphite Ferrules<br />

This is the ferrule of choice for high-temperature<br />

applications. Of the three ferrule types available, graphite<br />

is the softest, making it less damaging to capillary columns<br />

when overtightened. Graphite seals easily and does not<br />

stick to glass columns. Recommended for use with capillary<br />

columns. Temperature limit is 450 °C.<br />

Nut Size (in.) Ferrule i.d. (in.) Qty. Part No. Each (€)<br />

1/16 1/16 pkg. 10 02450972 55<br />

1/8 1/8 pkg. 10 09903915 54<br />

1/4 1/4 pkg. 10 09920140 43<br />

Graphite/Vespel Ferrules<br />

Graphite/vespel ferrules (15% graphite/85% polyimide) are<br />

recommended for use with GC/MS systems. Best choice for<br />

glass columns and polyimide-coated, fused-silica capillary<br />

columns. Can usually be removed easily from column.<br />

Temperature limit is 350 °C.<br />

Nut Size (in.) Ferrule i.d. (in.) Qty. Part No. Each (€)<br />

1/16 1/16 pkg. 10 09920127 84<br />

1/8 1/8 pkg. 1 N9302081 84<br />

1/4 1/4 pkg. 10 09903739 21<br />

Vespel Packed Stainless Steel Column Ferrules<br />

Vespel ferrules are not reusable; they tend to stick to<br />

columns after use at upper temperature limit. Not<br />

recommended for fused-silica capillary columns. Use these<br />

vespel ferrules on 1/16 in. metal tubing and glass-lined<br />

receivers (heated or ambient). Temperature limit is 350 °C.<br />

Nut Size (in.) Ferrule i.d. (in.) Qty. Part No. Each (€)<br />

1/8 1/8 pkg. 10 N9301360 64<br />

1/4 1/4 pkg. 10 N9301361 65<br />

Capillary Column Ferrules<br />

Package quantity: 10<br />

Nut Size Column Ferrule Graphite Graphite/Vespel<br />

(in.) i.d. (mm) i.d.(mm) Part No. Each (€) Part No. Each (€)<br />

1/16 0.18-0.25 0.4 N/A 09920104 84<br />

1/16 0.32 0.5 09903700 48 09920105 84<br />

1/16 0.32 0.5 (2-hole) N9306001 55 N9306000 110<br />

1/16 0.53 0.8 09920141 59 09920107 84<br />

1/16 0.18-0.25 0.4 (2-hole) N/A 04972392 19<br />

1/8 0.53 1.0 09903394 48 N/A<br />

1/8 0.32 0.5 (2-hole) 09903395 75 N/A<br />

1/8 0.32 0.5 09903981 48 N/A<br />

Note: 0.25-0.32 mm i.d. columns require 0.5 mm i.d. ferrules;<br />

0.53 mm i.d. columns require 0.8 mm i.d. ferrules.<br />

SilTite Metal Ferrules Nut and Ferrules Kit<br />

SilTite Metal Nut and<br />

Ferrules provide a continuous<br />

leak-free connection and are<br />

perfect for connecting<br />

your column to a GC/MS.<br />

From the SilTite drawing it<br />

can be seen that the taper of the inner nut is designed<br />

specifically for the angle of the SilTite ferrule. This ensures<br />

an even closure of the ferrule around the whole column to<br />

eliminate leaks.<br />

Features and Benefits:<br />

■ No need to re-tighten the nut<br />

■ Eliminate contamination<br />

■ Reusable nut<br />

■ Leak-free seal<br />

■ Starter kit contains 2 SilTite nuts and 10 ferrules<br />

The metal SilTite ferrule and nut are manufactured from<br />

the same material and will therefore not expand and contract<br />

at different coefficient rates. The base of the SilTite ferrule<br />

forms a perfect seal with the MS interface, covering the<br />

whole transfer interface. SilTite metal ferrules have a<br />

temperature limit well above the temperature capacity<br />

of the injector, MS interface or GC oven.<br />

Description Qty. Part No. Each (€)<br />

SilTite Ferrules Starter Kit 0.4 mm pkg. 10 N9306090 83<br />

SilTite Ferrules Starter Kit 0.5 mm pkg. 10 N9306091 83<br />

SilTite Ferrules Starter Kit 0.8 mm pkg. 10 N9306092 83<br />

SilTite Ferrules 0.4 mm pkg. 10 N9306093 57<br />

SilTite Ferrules 0.5 mm pkg. 10 N9306094 57<br />

SilTite Ferrules 0.8 mm pkg. 10 N9306095 57<br />

SilTite Nuts pkg. 5 N9306096 70<br />

94


Capillary Column Accessories<br />

Fittings<br />

Swagelok Fittings<br />

Swagelok TM Fittings<br />

Swagelok fittings from PerkinElmer are available in brass and stainless steel.<br />

The patented advanced-geometry back ferrule design provides a leak-tight tube connection on all Swagelok stainless<br />

steel tube fittings, in sizes 1/4 to 1/2 in., and 6 to 12 mm. Leak-tight seals that will withstand high-pressure, vibration,<br />

vacuum and temperature changes depend upon close tolerances and consistent, exacting quality control in conjunction<br />

with good design principles.<br />

Ease of installation<br />

Back ferrule axially advances the front ferrule<br />

Vibration fatigue resistance<br />

Wide variety of configurations<br />

Brass<br />

Stainless Steel<br />

Product Qty. Size Part No. Each (€) Part No. Each (€)<br />

Bulkhead Adapter pkg. 1 1/4 in. to 1/4 in. tube N9301267 48<br />

Back Ferrule pkg. 5 1/16 in. N9300040 12 N9300042 29<br />

1/8 in. N9300036 5 N9300038 17<br />

1/4 in. N9300030 6 N9300032 13<br />

Cross Union pkg. 1 1/8 in. N9301259 40<br />

Front Ferrule pkg. 5 1/16 in. N9300041 12 N9300043 30<br />

1/8 in. N9300037 6 N9300039 19<br />

1/4 in. N9300031 6 N9300033 13<br />

Male Adapter pkg. 1 1/4 in. tube to 1/8 in. NPT N9301266 8<br />

Tube to Pipe<br />

Male Connector pkg. 1 1/8 in. to 1/8 in. NPT N9301253 9<br />

1/8 in. to 1/4 in. NPT N9301254 9<br />

1/4 in. to 1/8 in. NPT N9301255 8<br />

1/4 in. to 1/4 in. NPT N9301269 8<br />

Nut pkg. 5 1/16 in. N9300058 14 N9300059 54<br />

1/8 in. N9300056 9 N9300057 33<br />

1/4 in. N9300054 9 N9300055 30<br />

Plug pkg. 1 1/16 in. N9300053 70<br />

1/8 in. N9300060 9 N9300061 44<br />

1/4 in. N9301268 5 N9301233 17<br />

Union pkg. 2 1/16 in. N9300048 31 N9300049 99<br />

1/8 in. N9300046 25 N9300047 69<br />

1/4 in. N9300044 17<br />

Union Tee pkg. 1 1/16 in. N9301221 37<br />

1/8 in. N9301222 27<br />

1/4 in. N9301223 27<br />

Reducing Union pkg. 1 1/8 in. to 1/16 in. N9300051 27 N9301225 47<br />

1/4 in. to 1/8 in. N9300050 22 N9301226 36<br />

1/4 in. to 1/16 in. N9301227 14<br />

Capillary Column Accessories Gas Chromatography<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

95


Capillary Columns<br />

Application Index<br />

Environmental<br />

Subject Column Page No.<br />

Forensic/Clinical Toxicology<br />

Subject Column Page No.<br />

Gas Chromatography Capillary Columns<br />

Amines and Phenols Elite-5Amine 99<br />

EPA Method 508 – Pesticides Elite-5 99<br />

EPA Method 508 –<br />

Organochlorine Pesticides Elite-CLPesticides 100<br />

Elite-CLPesticides2 100<br />

EPA Method 524.2 Elite-624 (GC/MS) 101<br />

EPA Method 551.1 Elite-5 101<br />

EPA Method 551.1 –<br />

Chlorinated Disinfection Byproducts Elite-200 102<br />

EPA Method 8021 –<br />

Volatile Organics Elite-Volatiles 104<br />

EPA Method 8081 –<br />

Pesticides Elite-35 102<br />

EPA Method 8081A –<br />

Organochlorine Pesticides Elite-CLPesticides 103<br />

Elite-CLPesticides2 103<br />

EPA Method 8260B –<br />

Volatile Organics Elite-VMS 105<br />

EPA Method 8260B –<br />

Volatile Organics Elite-VMS 106<br />

EPA Method 8270 –<br />

Semi-Volatile Organics Elite-5 ms 107<br />

<strong>Essential</strong> Oils –<br />

Citronella Java Oil Elite-1 108<br />

Nitrogen Containing Herbicides Elite-5 108<br />

Pesticides Elite-5 109<br />

Synthetic <strong>Essential</strong> Oil Elite-1 109<br />

Food and Flavors<br />

Subject Column Page No.<br />

Brewing – Beer Elite-BAC 110<br />

<strong>Essential</strong> Oils – Lemon Oil Elite-5 110<br />

<strong>Essential</strong> Oils – Native Spearmint Oil Elite-WAX ETR 111<br />

<strong>Essential</strong> Oils –<br />

Synthetic Mushroom Aroma Elite-WAX ETR 111<br />

Sugars – As Alditol Acetates Elite-225 112<br />

TCA in Wine Elite-5 ms 112<br />

Anabolic Steroids – Underivatized Elite-5 113<br />

Blood Alcohol Elite-BAC 114<br />

Cannabinoids – TMS Derivatives Elite-5 113<br />

Cocaine and Metabolites Elite-5 115<br />

Sympathomimetic Amines –<br />

HFBA Derivatives Elite-5 115<br />

Industrial Chemicals<br />

Subject Column Page No.<br />

Alcohols and Aldehydes Elite-WAX ETR 116<br />

Alcohol Mixtures Elite-WAX ETR 116<br />

Aldehydes Elite-WAX 117<br />

Amines & Phenols Elite-5Amine 117<br />

Aromatics Elite-WAX ETR 118<br />

Industrial Solvents Elite-MWAX 118<br />

Industrial Solvents Elite-WAX ETR 118<br />

Petroleum<br />

Subject Column Page No.<br />

Prudhoe Bay Crude Oil Elite-1GC-79 119<br />

Volatile Hydrocarbons Elite-Q PLOT 119<br />

96


Capillary Columns<br />

U.S. EPA Methods<br />

U.S. EPA Drinking Water<br />

Test Methods<br />

U.S. EPA Organic Chemical<br />

Analysis Waste Water Methods<br />

Method Column Recommendations Part No. Each (€) Method Column Recommendations Part No. Each (€)<br />

501.3 Elite-624 30 m x .53 mm i.d., 3.00 μm N9316207 700 601† Elite-624 30 m x .53 mm i.d., 3.00 μm N9316207 700<br />

Elite-624** 75 m x .53 mm i.d., 3.00 μm N9316208 1249<br />

Elite-624** 75 m x .53 mm i.d., 3.00 μm N9316208 1249<br />

Elite-Volatiles** 30 m x .45 mm i.d., 2.55 μm N9316392 764<br />

Elite-Volatiles** 30 m x .45 mm i.d., 2.55 μm N9316392 764<br />

Elite-Volatiles** 75 m x .45 mm i.d., 2.55 μm N9316393 1274<br />

Elite-Volatiles** 75 m x .45 mm i.d., 2.55 μm N9316393 1274<br />

Elite-502.2 105 m x .53 mm i.d., 3.00 μm N9316190 1210<br />

Elite-502.2 105 m x .53 mm i.d., 3.00 μm N9316190 1210<br />

502.2† Elite-624* 30 m x .53 mm i.d., 3.00 μm N9316207 700 602 Elite-624** 30 m x .53 mm i.d., 3.00 μm N9316207 700<br />

Elite-624** 75 m x .53 mm i.d., 3.00 μm N9316208 1249<br />

Elite-Volatiles** 30 m x .45 mm i.d., 2.55 μm N9316392 764<br />

Elite-Volatiles 30 m x .45 mm i.d., 2.55 μm N9316392 764<br />

Elite-502.2 105 m x .53 mm i.d., 3.00 μm N9316190 1210<br />

Elite-Volatiles** 75 m x .45 mm i.d., 2.55 μm N9316393 1274 603 Elite-624 30 m x .53 mm i.d., 3.00 μm N9316207 700<br />

Elite-502.2 105 m x .53 mm i.d., 3.00 μm N9316190 1210<br />

Elite-Volatiles** 30 m x .45 mm i.d., 2.55 μm N9316392 764<br />

503.1 Elite-624 30 m x .53 mm i.d., 3.00 μm N9316207 700 604 Elite-5ms** 30 m x .53 mm i.d., 1.50 μm N9316300 700<br />

Elite-Volatiles** 30 m x .45 mm i.d., 2.55 μm N9316392 764 606 Elite-1 15 m x .53 mm i.d., 1.50 μm N9316046 356<br />

504 Elite-1* 30 m x .32 mm i.d., 0.25 μm N9316023 547 607 Elite-5 30 m x .53 mm i.d., 1.50 μm N9316100 611<br />

Elite-624** 30 m x .53 mm i.d., 3.00 μm N9316207 700<br />

Elite-5ms** 30 m x .53 mm i.d., 1.50 μm N9316300 700<br />

Elite-Volatiles** 30 m x .45 mm i.d., 2.55 μm N9316392 764 608 Elite-608** 30 m x .53 mm i.d., 0.83 μm N9316197 700<br />

505 Elite-1* 30 m x .32 mm i.d., 1.00 μm N9316024 573 609 Elite-5 30 m x .53 mm i.d., 1.50 μm N9316100 611<br />

Elite-17 30 m x .32 mm i.d., 0.50 μm N9316129 547<br />

Elite-5ms** 30 m x .25 mm i.d., 1.00 μm N9316283 611<br />

507 Elite-5* 30 m x .25 mm i.d., 0.25 μm N9316076 509 610 Elite-5 30 m x .32 mm i.d., 0.25 μm N9316086 573<br />

Elite-5ms** 30 m x .25 mm i.d., 0.25 μm N9316282 611<br />

Elite-5ms** 30 m x .32 mm i.d., 0.25 μm N9316293 636<br />

Elite-1701* 30 m x .25 mm i.d., 0.25 μm N9316234 547 611 Elite-5 15 m x .53 mm i.d., 1.50 μm N9316098 356<br />

508 Elite-5* 30 m x .25 mm i.d., 0.25 μm N9316076 509<br />

Elite-5ms** 15 m x .53 mm i.d., 1.50 μm N9316299 434<br />

Elite-5ms** 30 m x .25 mm i.d., 0.25 μm N9316282 611 612 Elite-1 30 m x .32 mm i.d., 1.00 μm N9316024 573<br />

Elite-608** 30 m x .32 mm i.d., 0.50 μm N9316191 547<br />

Elite-5ms** 30 m x .25 mm i.d., 1.00 μm N9316283 611<br />

Elite-1701* 30 m x .25 mm i.d., 0.25 μm N9316234 547 613 Elite-5ms 60 m x .25 mm i.d., 0.10 μm N9316285 1084<br />

513 Elite-5ms 60 m x .25 mm i.d., 0.10 μm N9316285 1084<br />

Elite-5ms** 60 m x .32 mm i.d., 0.10 μm N9316296 1186<br />

Elite-5ms 60 m x .32 mm i.d., 0.10 μm N9316296 1186 615 Elite-608** 30 m x .53 mm i.d., 0.83 μm N9316197 700<br />

515 Elite-1* 30 m x .32 mm i.d., 0.25 μm N9316023 547<br />

Elite-1701 30 m x .53 mm i.d., 1.00 μm N9316255 740<br />

515.2 Elite-5* 30 m x .32 mm i.d., 0.25 μm N9316086 573 619 Elite-17 30 m x .53 mm i.d., 1.00 μm N9316136 636<br />

Elite-5ms** 30 m x .32 mm i.d., 0.25 μm N9316293 636<br />

Elite-35** 30 m x .53 mm i.d., 1.00 μm N9316152 721<br />

Elite-1701* 30 m x .32 mm i.d., 0.25 μm N9316243 573 622 Elite-5ms** 30 m x .53 mm i.d., 1.50 μm N9316300 700<br />

524.2† Elite-624* 30 m x .25 mm i.d., 1.40 μm N9316201 573 624 Elite-624 30 m x .25 mm i.d., 1.40 μm N9316201 573<br />

Elite-624* 30 m x .53 mm i.d., 3.00 μm N9316207 700<br />

Elite-624 30 m x .53 mm i.d., 3.00 μm N9316207 700<br />

Elite-624* 75 m x .53 mm i.d., 3.00 μm N9316208 1249<br />

Elite-624 75 m x .53 mm i.d., 3.00 μm N9316208 1249<br />

Elite-5* 30 m x .32 mm i.d., 1.00 μm N9316087 547<br />

Elite-Volatiles** 30 m x .45 mm i.d., 2.55 μm N9316392 764<br />

Elite-5ms** 30 m x .25 mm i.d., 1.00 μm N9316283 611<br />

Elite-Volatiles** 75 m x .45 mm i.d., 2.55 μm N9316393 1274<br />

Elite-Volatiles** 30 m x .45 mm i.d., 2.55 μm N9316392 764<br />

Elite-502.2 105 m x .53 mm i.d., 3.00 μm N9316190 1210<br />

Elite-Volatiles** 75 m x .45 mm i.d., 2.55 μm N9316393 1274 625 Elite-5ms** 30 m x .32 mm i.d., 0.25 μm N9316293 636<br />

525 Elite-5* 30 m x .32 mm i.d., 0.25 μm N9316086 573 680 Elite-5* 30 m x .32 mm i.d., 0.25 μm N9316086 573<br />

Elite-5ms** 30 m x .25 mm i.d., 1.00 μm N9316283 611<br />

Elite-5ms** 30 m x .32 mm i.d., 0.25 μm N9316293 636<br />

548.1 Elite-5* 30 m x .25 mm i.d., 0.25 μm N9316076 509 1618 Elite-1 30 m x .53 mm i.d., 1.50 μm N9316050 636<br />

Elite-5* 30 m x .32 mm i.d., 0.25 μm N9316086 573<br />

Elite-608** 30 m x .53 mm i.d., 0.83 μm N9316197 700<br />

Elite-5ms** 30 m x .25 mm i.d., 0.25 μm N9316282 611<br />

Elite-1701 30 m x .53 mm i.d., 1.00 μm N9316255 740<br />

Elite-5ms** 30 m x .32 mm i.d., 0.25 μm N9316293 636 1624 Elite-624 75 m x .45 mm i.d., 2.55 μm N9316206 1249<br />

Elite-Volatiles** 30 m x .45 mm i.d., 2.55 μm N9316392 764<br />

Elite-624** 75 m x .53 mm i.d., 3.00 μm N9316208 1249<br />

551 Elite-1* 30 m x .32 mm i.d., 1.00 μm N9316024 573 1625 Elite-5* 30 m x .25 mm i.d., 0.25 μm N9316076 509<br />

Elite-5ms** 30 m x .25 mm i.d., 1.00 μm N9316283 611<br />

Elite-5ms** 30 m x .25 mm i.d., 0.25 μm N9316282 611<br />

552 Elite-1701* 30 m x .32 mm i.d., 0.25 μm N9316243 573 1653 Elite-5* 30 m x .32 mm i.d., 0.25 μm N9316086 573<br />

* Specified in EPA method.<br />

Elite-5ms** 30 m x .32 mm i.d., 0.25 μm N9316293 636<br />

** This column is highly recommended by PerkinElmer for this EPA method.<br />

† The choice of column for this purge-and-trap method may depend on your<br />

sample concentrator to GC interface.<br />

Capillary Columns Gas Chromatography<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

97


Capillary Columns<br />

U.S. EPA Methods<br />

U.S. EPA Solid Waste<br />

Test Methods<br />

Gas Chromatography Capillary Columns<br />

Method Column Recommendations Part No. Each (€)<br />

8010† Elite-624 75 m x .53 mm i.d., 3.00 μm N9316208 1249<br />

Elite-Volatiles** 75 m x .45 mm i.d., 2.55 μm N9316393 1274<br />

8015 Elite-624 30 m x .53 mm i.d., 3.00 μm N9316207 700<br />

Elite-Volatiles** 30 m x .45 mm i.d., 2.55 μm N9316392 764<br />

8020 Elite-624 30 m x .53 mm i.d., 3.00 μm N9316207 700<br />

Elite-Volatiles** 30 m x .45 mm i.d., 2.55 μm N9316392 764<br />

8030 Elite-624 30 m x .53 mm i.d., 3.00 μm N9316207 700<br />

Elite-Volatiles** 30 m x .45 mm i.d., 2.55 μm N9316392 764<br />

8040 Elite-5ms 30 m x .53 mm i.d., 1.50 μm N9316300 700<br />

8060 Elite-1 15 m x .53 mm i.d., 1.50 μm N9316046 356<br />

8080 Elite-608** 30 m x .53 mm i.d., 0.83 μm N9316197 700<br />

8081 Elite-5* 30 m x .53 mm i.d., 1.50 μm N9316100 611<br />

Elite-608** 30 m x .53 mm i.d., 0.83 μm N9316197 700<br />

Elite-1701* 30 m x .53 mm i.d., 1.00 μm N9316255 740<br />

8090 Elite-5 30 m x .53 mm i.d., 1.50 μm N9316100 611<br />

Elite-5ms** 30 m x .53 mm i.d., 1.50 μm N9316300 700<br />

8100 Elite-5 30 m x .32 mm i.d., 0.25 μm N9316086 573<br />

Elite-5ms** 30 m x .32 mm i.d., 0.25 μm N9316293 636<br />

8120 Elite-1 30 m x .32 mm i.d., 1.00 μm N9316024 573<br />

Elite-5ms** 30 m x .25 mm i.d., 1.00 μm N9316283 611<br />

Elite-5ms** 30 m x .32 mm i.d., 1.00 μm N9316294 636<br />

8140 Elite-1 30 m x .53 mm i.d., 1.50 μm N9316050 636<br />

Elite-1701** 30 m x .53 mm i.d., 1.00 μm N9316255 740<br />

8141 Elite-5* 15 m x .53 mm i.d., 1.50 μm N9316098 356<br />

Elite-5ms** 30 m x .53 mm i.d., 1.50 μm N9316300 700<br />

Elite-35** 30 m x .53 mm i.d., 0.50 μm N9316153 611<br />

8150 Elite-608** 30 m x .53 mm i.d., 0.83 μm N9316197 700<br />

Elite-1701 30 m x .53 mm i.d., 1.00 μm N9316255 740<br />

8240† Elite-624 30 m x .53 mm i.d., 3.00 μm N9316207 700<br />

Elite-624 75 m x .53 mm i.d., 3.00 μm N9316208 1249<br />

Elite-Volatiles** 30 m x .45 mm i.d., 2.55 μm N9316392 764<br />

Elite-Volatiles** 75 m x .45 mm i.d., 2.55 μm N9316393 1274<br />

8250 Elite-5 30 m x .53 mm i.d., 1.50 μm N9316100 611<br />

Elite-5ms** 30 m x .53 mm i.d., 1.50 μm N9316300 700<br />

8260 Elite-5* 30 m x .32 mm i.d., 1.00 μm N9316087 547<br />

Elite-624* 30 m x .53 mm i.d., 3.00 μm N9316207 700<br />

Elite-624 75 m x .53 mm i.d., 3.00 μm N9316208 1249<br />

Elite-Volatiles** 30 m x .45 mm i.d., 2.55 μm N9316392 764<br />

Elite-Volatiles** 75 m x .45 mm i.d., 2.55 μm N9316393 1274<br />

Elite-5ms** 30 m x .25 mm i.d., 1.00 μm N9316283 611<br />

8260B Elite-Volatiles** 30 m x .25 mm i.d., 1.40 μm N9316388 638<br />

8270 Elite-5* 30 m x .32 mm i.d., 1.00 μm N9316087 547<br />

Elite-5ms** 30 m x .25 mm i.d., 0.50 μm N9316284 611<br />

8280 Elite-5* 30 m x .25 mm i.d., 0.25 μm N9316076 509<br />

Elite-5ms** 30 m x .25 mm i.d., 1.00 μm N9316283 611<br />

* Specified in EPA method.<br />

** This column is highly recommended by PerkinElmer for this EPA method.<br />

† The choice of column for this purge-and-trap method may depend on your<br />

sample concentrator to GC interface.<br />

98


Capillary Column Applications<br />

Environmental<br />

Amines and Phenols<br />

U.S. EPA Method 508 – Pesticides<br />

1. Etridiazole (50 pg/μL)<br />

2. Chlorneb (1000 pg/μL)<br />

3. Propachlor (1000 pg/μL)<br />

4. Trifluralin (50 pg/μL)<br />

5. a-BHC (20 pg/μL)<br />

6. Hexachlorobenzene (10 pg/μL)<br />

7. b-BHC (20 pg/μL)<br />

8. g-BHC (30 pg/μL)<br />

9. PCNB (impurity) (100 pg/μL)<br />

10. PCNB (IS) (100 pg/μL)<br />

11. d-BHC (20 pg/μL)<br />

12. Chlorothalonil (50 pg/μL)<br />

13. Heptachlor (20 pg/μL)<br />

14. Aldrin (30 pg/μL)<br />

15. DCPA (50 pg/μL)<br />

16. DCB (SS) (5000 pg/μL)<br />

17. Heptachlor Epoxide (30 pg/μL)<br />

18. g-Chlordane (30 pg/μL)<br />

19. Endosulfan I (30 pg/μL)<br />

20. a-Chlordane (30 pg/μL)<br />

Column: Elite-5<br />

Dimensions: 30 m, 0.25 mm i.d., 0.25 μm<br />

Sample: 2.0 μL splitless injection of a pesticide mix<br />

Splitless Hold: 0.75 min.<br />

Oven Temperature: 60 °C to 300 °C @ 4 °C/min.<br />

(hold 10 min.)<br />

Injector: 250 °C<br />

Detector: ECD, 320 °C<br />

Carrier Gas: Helium @ 30 cm/sec.<br />

Part No.<br />

1<br />

2<br />

3<br />

N9316076<br />

4<br />

5<br />

6<br />

7<br />

8<br />

9<br />

10<br />

11<br />

2 4 6 8 10<br />

TIME (MIN.)<br />

12<br />

21. Dieldrin (40 pg/μL)<br />

22. Endrin (30 pg/μL)<br />

23. Endosulfan II (30 pg/μL)<br />

24. Chlorobenzilate (1000 pg/μL)<br />

25. P, P'-DDD (50 pg/μL)<br />

26. Endrin Aldehyde (50 pg/μL)<br />

27. Endosulfan Sulfate (30 pg/μL)<br />

28. P, P'-DDD (120 pg/μL)<br />

29. Methoxychlor (100 pg/μL)<br />

30. cis-Permethrin (1000 pg/μL)<br />

31. trans-Permethrin (1000 pg/μL)<br />

13<br />

1<br />

2 3<br />

4<br />

6<br />

7<br />

4 8 12 16 20 24 28 32 36 40 44 48 52<br />

5<br />

TIME (MIN.)<br />

9 10<br />

8<br />

1. Diethylamine<br />

2. Pyridine<br />

3. Morpholine<br />

4. Phenol<br />

5. Aniline<br />

6. 2-Chlorophenol<br />

7. Diethylenetriamine<br />

8. Octylamine<br />

9. 1-Methyl-2-Pyrrolidinone<br />

10. 2-Nitrophenol<br />

11. 2, 6-Dimethylaniline<br />

12. Nicotine<br />

13. 2-Nitroaniline<br />

Column: Elite-5Amine<br />

Dimensions: 30 m, 0.32 mm i.d., 1.0 μm<br />

Sample: 1.0 μL split injection of<br />

miscellaneous amines<br />

and phenols in water<br />

On-Column Conc.: 22 ng<br />

Oven: 120 °C to 220 °C @ 10 °C/min.<br />

Injector & Detector: 305 °C<br />

Carrier Gas: Hydrogen<br />

Linear Velocity: 38 cm/sec. set @ 120 °C<br />

FID Sensitivity: 6.4 x 10-11 AFS<br />

Split Ratio: 25:1<br />

Part No.<br />

12<br />

16<br />

21<br />

14<br />

15<br />

17<br />

11 19<br />

18<br />

13<br />

N9316677<br />

20 22<br />

26<br />

28<br />

24 25<br />

23<br />

27<br />

29<br />

30 31<br />

Capillary Column Applications Gas Chromatography<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

99


Capillary Column Applications<br />

Environmental<br />

Gas Chromatography Capillary Column Applications<br />

U.S. EPA Method 508 – Organochlorine Pesticides<br />

1<br />

2<br />

3<br />

6 8 10 12 14 16 18 20<br />

TIME (MIN.)<br />

Column: Elite-CLPesticides<br />

Dimensions: 30 m, 0.32 mm i.d., 0.50 μm,<br />

Elite-CLPesticides (N9316664)<br />

Dimensions: 30 m, 0.32 mm i.d., 0.25 μm,<br />

Elite-CLPesticides2 (N9316662)<br />

EPA 508.1 list w/added compounds<br />

Oven: 120 °C (hold 1 min.) to 300 °C @ 9 °C/min.<br />

(hold 10 min.)<br />

Injector: Direct, Uniliner ® inlet liner, 200 °C<br />

Dead Time: 1.797 (Elite-CLPesticides),<br />

1.663 (Elite-CLPesticides2)<br />

Head Pressure: 12 psi (constant)<br />

Carrier Gas: Helium<br />

Flow: 2.1 mL/min. @ 120 °C<br />

Part No.<br />

Part No.<br />

10,11,12<br />

4<br />

5,6<br />

7<br />

8,9<br />

14<br />

13<br />

N9316664<br />

N9316662<br />

15<br />

18,19<br />

16,<br />

17<br />

24,25<br />

22<br />

23<br />

26 28<br />

27 32<br />

20,<br />

21<br />

31<br />

30<br />

29<br />

33<br />

34<br />

35<br />

36<br />

37<br />

38<br />

1<br />

1. Hexachloropentadiene<br />

2. Etridiazole<br />

3. Chlorneb<br />

4. Hexachlorobenzene<br />

5. Propachlor<br />

6. a-BHC<br />

7. Simazine<br />

8. g-BHC<br />

9. Atrazine<br />

10. Trifluralin<br />

11. Pentachloronitrobenzene<br />

12. b-BHC<br />

13. d-BHC<br />

14. Metribuzin<br />

15. Heptachlor<br />

16. Aldrin<br />

17. Chlorothalonil<br />

18. 4, 4'-Dibromobiphenyl<br />

19. Alachlor<br />

2<br />

3<br />

10<br />

5<br />

4 6<br />

8,11 1317<br />

9<br />

7<br />

12<br />

20. Metalachlor<br />

21. DCPA (Dacthal ® )<br />

22. Heptachlor Epoxide<br />

23. g-Chlordane<br />

24. Cyanazine<br />

25. a-Chlordane<br />

26. 4, 4'-DDE<br />

27. Endosulfan I<br />

28. Dieldrin<br />

29. Endrin<br />

30. Chlorobenzilate<br />

31. 4, 4'-DDD<br />

32. Endosulfan II<br />

33. 4, 4'-DDT<br />

34. Endrin Aldehyde<br />

35. Methoxychlor<br />

36. Endosulfan Sulfate<br />

37. cis-Permethrin<br />

38. trans-Permethrin<br />

6 8 10 12 14 16 18 20<br />

TIME (MIN.)<br />

14<br />

16<br />

18,21<br />

24<br />

19<br />

20<br />

22<br />

25 26 27<br />

23<br />

28<br />

31<br />

29,<br />

30<br />

32<br />

33<br />

34<br />

36<br />

35<br />

37<br />

38<br />

100


Capillary Column Applications<br />

Environmental<br />

U.S. EPA Method 524.2<br />

Column: Elite-624 (GC/MS)<br />

Dimensions: 75 m, 0.53 mm i.d., 3.0 μm<br />

Sample: 20 ppm of 502.2 Standards Calibration Mixes 1-6<br />

Oven: 35 °C (hold 8 min.) to 220 °C at 10 °C/min. (hold 3 min.)<br />

Detector: MS, 250 °C<br />

Scan Range: 45-300AMU<br />

Purge: 11 min.<br />

Purge and Trap: Tenax, Silica Gel, charcoal<br />

Desorb Preheat: 220 °C, 2 min. desorb at 225 °C<br />

Desorb Flow Rate: 10 mL/min.<br />

Part No.<br />

Standards used are 524 Volatiles Kit:<br />

1. Dichlorodifluoromethane<br />

2. Chloromethane<br />

3. Vinyl Chloride<br />

4. Bromomethane<br />

5. Chloroethane<br />

6. Trichlorofluoromethane<br />

7. 1, 1-Dichloroethene<br />

8. Methylene Chloride<br />

9. trans-1, 2-Dichloroethene<br />

10. 1, 1-Dichloroethane<br />

11. cis-1, 2-Dichloroethene<br />

12. 2, 2-Dichloropropane<br />

13. Bromochloromethane<br />

14. Chloroform<br />

15. 1, 1, 1-trichloroethane<br />

16. Carbon Tetrachloride<br />

U.S. EPA Method 551.1<br />

1<br />

N9316208<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

1 3<br />

2<br />

17. 1, 1-Dichloropropene<br />

18. Benzene<br />

19. 1, 2-Dichloroethane<br />

20. Trichloroethene<br />

21. 1, 2-Dichloropropane<br />

22. Dibromomethane<br />

23. Bromodichloromethane<br />

24. cis-1, 3-Dichloropropene<br />

25. Toluene<br />

26. trans-1, 3-Dichloropropene<br />

27. 1, 1, 2-Trichloroethane<br />

9<br />

10<br />

11<br />

6<br />

4<br />

5<br />

10 20 30<br />

TIME (MIN.)<br />

14<br />

12<br />

13<br />

15<br />

7<br />

8 9<br />

10<br />

11,12 13 14<br />

15<br />

28. Tetrachloroethene<br />

29. 1, 3-Dichloropropane<br />

30. Dibromochloromethane<br />

31. 1, 2-Dibromoethane<br />

32. Chlorobenzene<br />

33. 1, 1, 1, 2-tetrachloroethane<br />

34. Ethylbenzene<br />

35. m-Xylene<br />

36. p-Xylene<br />

37. o-Xylene<br />

38. Styrene<br />

16,17 18<br />

19<br />

33,34<br />

25<br />

28 32<br />

20<br />

22<br />

30<br />

27<br />

23 24 31<br />

21 26<br />

29<br />

35,36<br />

37,38<br />

39. Bromoform<br />

40. Isopropylbenzene<br />

41. Bromobenzene<br />

42. 1, 1, 2, 2-Tetrachloroethane<br />

43. 1, 2, 3-Trichloropropane<br />

44. Propylbenzene<br />

45. 2-Chlorotoluene<br />

46. 1, 3, 5-Trimethylbenzene<br />

47. 4-Chlorotoluene<br />

48. tert-Butylbenzene<br />

49. 1, 2, 4-Trimethylbenzene<br />

43,44<br />

41,42 54<br />

50<br />

53<br />

40<br />

46 49<br />

48<br />

55<br />

47<br />

5 10 15 20 25<br />

TIME (MIN.)<br />

16<br />

17<br />

18<br />

1. Chloroform<br />

2. 1, 1, 1-Trichloroethane<br />

3. Carbon Tetrachloride<br />

4. Trichloroacetonitrile<br />

5. Trichloroethylene<br />

6. Bromodichloromethane<br />

7. Chloral Hydrate<br />

8. Dichloroacetonitrile<br />

9. 1, 1-Dichloro-2-Propanone<br />

10. 1, 1, 2-Trichloroethane<br />

11. Chloropicrin<br />

19<br />

20<br />

21<br />

39<br />

45<br />

51,52<br />

56<br />

57<br />

58<br />

59 60<br />

50. sec-Butylbenzene<br />

51. 1, 3-Dichlorobenzene<br />

52. p-Isopropyltoluene<br />

53. 1, 4-Dichlorobenzene<br />

54. n-Butylbenzene<br />

55. 1, 2-Dichlorobenzene<br />

56. 1, 2-Dibromo-3-Chloropropane<br />

57. 1, 2, 4-Trichlorobenzene<br />

58. Hexachlorobutadiene<br />

59. Naphthalene<br />

60. 1, 2, 3-Trichlorobenzene<br />

12. Dibromochloromethane<br />

13. 1, 2-Dibromoethane (EDB)<br />

14. Tetrachloroethylene<br />

15. Bromochloroacetonitrile<br />

16. 1, 1, 1-trichloro-2-propanone<br />

17. Bromoform<br />

18. Dibromoacetonitrile<br />

19. 1, 2, 3-Trichloropropane<br />

20. 4-Bromofluorobenzene (I.S.)<br />

21. 1,2-Dibromo-3-Chloropropane (DBCP)<br />

Column: Elite-5<br />

Dimensions: 30 m, 0.25 mm i.d., 1.0 μm<br />

Sample: 1.0 μL split injection, 1 ng on-column concentration<br />

Oven: 35 °C (hold 22 min.) to 200 °C at 10 °C/min.<br />

Injector: 200 °C<br />

Detector: ECD, 290 °C<br />

Carrier: Helium at 30 cm/sec.<br />

Split Ratio: 10:1<br />

Part No.<br />

N9316077<br />

Capillary Column Applications Gas Chromatography<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

101


Capillary Column Applications<br />

Environmental<br />

Gas Chromatography Capillary Column Applications<br />

U.S. EPA Method 551.1 – Chlorinated Disinfection Byproducts<br />

1<br />

3<br />

U.S. EPA Method 8081 – Pesticides<br />

Column: Elite-35<br />

Dimensions: 30 m, 0.32 mm i.d., 0.50 μm<br />

Oven Temperature: 120 °C (hold 1 min.) to 285 °C<br />

@ 8.5 °C/min. (hold 6 min.)<br />

Injector: 200 °C<br />

Detector: ECD, 300 °C<br />

Carrier Gas: Helium<br />

Part No.<br />

2<br />

5,6<br />

4<br />

12<br />

8, 14<br />

7 9<br />

N9316147<br />

10<br />

11,13<br />

1. 2,4,5,6-tetrachloro-m-xylene<br />

2. a-BHC<br />

3. g-GHC (lindane)<br />

4. b-BHC<br />

5. d-BHC<br />

6. Heptachlor<br />

7. Aldrin<br />

8. Heptachlor Epoxide<br />

9. g-Chlordane<br />

10. a-Chlordane<br />

11. 4,4'-DDE<br />

17<br />

10 20 30<br />

15<br />

16<br />

12. Endosulfan I<br />

13. Dieldrin<br />

14. Endrin<br />

15. 4,4'-DDT<br />

16. Endosulfan II<br />

17. 4,4'-DDD<br />

18. Endrin Aldehyde<br />

19. Methoxychlor<br />

20. Endosulfan Sulfate<br />

21. Endrin Ketone<br />

22. Decachlorobiphenyl<br />

18,19<br />

20<br />

1<br />

1. Chloroform<br />

2. 1,1,1-Trichloroethane<br />

3. Carbon Tetrachloride<br />

4. Trichloroacetonitrile<br />

5. Trichloroethylene<br />

6. Bromodichloromethane<br />

7. Chloral Hydrate<br />

8. Dichloroacetonitrile<br />

9. 1,1-Dichloro-2-Propanone<br />

10. 1,1, 2-Trichloroethane<br />

11. Chloropicrin<br />

21<br />

2<br />

3<br />

4<br />

6<br />

5<br />

7<br />

8<br />

9<br />

10<br />

12<br />

11<br />

12 15 18 21 24<br />

13<br />

TIME (MIN.)<br />

12. Dibromochloromethane<br />

13. 1, 2-Dibromoethane (EDB)<br />

14. Tetrachloroethylene<br />

15. Bromochloroacetonitrile<br />

16. 1,1,1-Trichloro-2-Propanone<br />

17. Bromoform<br />

18. Dibromoacetonitrile<br />

19. 1, 2, 3-Trichloropropane<br />

20. 4-Bromofluorobenzene (IS)<br />

21. 1, 2-Dibromo-3-Chloropropane (DBCP)<br />

Column: Elite-200<br />

Dimensions: 30 m, 0.25 mm i.d., 1.0 μm<br />

Sample: 1.0 μL split injection,<br />

1 ng on-column concentration<br />

Oven: 35 °C (hold 22 min.) to 200 °C<br />

@ 10 °C/min.<br />

Injector/Detector: 200 °C/290 °C<br />

Carrier Gas: Helium<br />

Linear Velocity: 30 cm/sec. @ 50 °C<br />

ECD Sensitivity: 20 kHz full scale<br />

Split Ratio: 10:1<br />

TIME (MIN.) Part No. N9316623<br />

16<br />

17<br />

18<br />

14 15<br />

20<br />

19<br />

21<br />

22<br />

102


Capillary Column Applications<br />

Environmental<br />

U.S. EPA Method 8081A – Organochlorine Pesticides<br />

1<br />

1<br />

2<br />

2<br />

3<br />

6,7<br />

4 8<br />

9<br />

10<br />

11 12<br />

16<br />

15<br />

14<br />

13<br />

17 19<br />

20,22<br />

10 15 20 25<br />

TIME (MIN.)<br />

3<br />

5<br />

4<br />

5<br />

6<br />

7<br />

8<br />

9<br />

10<br />

12<br />

11<br />

21<br />

23<br />

24<br />

25<br />

10 15 20 25<br />

TIME (MIN.)<br />

20<br />

13<br />

14<br />

16<br />

15<br />

18<br />

23<br />

17<br />

19<br />

18<br />

22<br />

21<br />

24<br />

26<br />

27<br />

28<br />

26<br />

25 27<br />

28<br />

29<br />

29<br />

1. Dibromochloropropane<br />

2. Hexachlorocyclopentadiene<br />

3. 2, 4, 5, 6-Tetrachloro-m-Xylene<br />

4. Hexachlorobenzene<br />

5. cis-Diallate<br />

6. a-BHC<br />

7. trans-Diallate<br />

8. g-BHC<br />

9. b-BHC<br />

10. d-BHC<br />

11. Heptachlor<br />

12. Aldrin<br />

13. Isodrin<br />

14. Heptachlor Epoxide<br />

15. g-Chlordane<br />

16. a-Chlordane<br />

17. 4, 4'-DDE<br />

18. Endosulfan I<br />

19. Dieldrin<br />

20. Chlorobenzilate<br />

21. Endrin<br />

22. 4,4'-DDD<br />

23. Endosulfan II<br />

24. 4, 4'-DDT<br />

25. Endrin Aldehyde<br />

26. Methoxychlor<br />

27. Endosulfan Sulfate<br />

28. Endrin Ketone<br />

29. Decachlorobiphenyl<br />

Column: Elite-CLPesticides and<br />

Elite-CLPesticides2<br />

Dimensions: 30 m, 0.32 mm i.d., 0.50 μm,<br />

Elite-CLPesticides (N9316664)<br />

Dimensions: 30 m, 0.32 mm i.d., 0.25 μm,<br />

Elite-CLPesticides2 (N9316670)<br />

On-Column Conc.: 16–160 pg<br />

Oven: 80 °C (hold 1 min.) to 300 °C @ 10 °C/min.<br />

(hold 15 min.)<br />

Injector: Direct, Uniliner ® inlet liner<br />

Detector: ECD, 300 °C, with Anode Purge<br />

Dead Time: 1.9 min.<br />

Head Pressure: 8.7 psi (constant)<br />

Flow Rate: Helium @ 1.3 mL/min. @ 120 °C<br />

Part No.<br />

Part No.<br />

N9316664<br />

N9316670<br />

Capillary Column Applications Gas Chromatography<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

103


Capillary Column Applications<br />

Environmental<br />

Gas Chromatography Capillary Column Applications<br />

U.S. EPA Method 8021 – Volatile Organics<br />

Column: Elite-Volatiles<br />

Dimensions: 20 ppb in 5 mL of RO Water. 75 m, 0.45 mm i.d., 2.55 μm<br />

Concentrator: Purge and Trap<br />

Trap: Vocarb 3000<br />

Purge: 11 min. at 40 mL/min.<br />

Dry Purge: 1 min. at 40 mL/min. (MCS bypassed with Silcosteel tubing)<br />

Desorb Preheat: 245 °C<br />

Desorb: 250 °C for 2 min.<br />

Bake: 260 °C for 8 min.<br />

Interface: direct<br />

Transfer Line: 0.32 mm i.d.<br />

Oven: 35 °C (hold 12 min.) to 60 °C at 5 °C/min. (hold 1 min.) to 220 °C at 17 °C/min.<br />

(hold 3 min.)<br />

Carrier: Helium at 9 mL/min.<br />

Detectors: PID/ELCD<br />

PID: makeup 7 mL/min., purge 7 mL/min., set at 0.35 mV base temp 200 °C<br />

ELCD: Reaction Gas 25mL/min.<br />

Reaction Temp.: 940 °C, propanol flow 470 μL/min.<br />

Part No.<br />

PID<br />

3<br />

7<br />

N9316393<br />

1. Dichlorodifluoromethane<br />

2. Chloromethane<br />

3. Vinyl Chloride<br />

4. Bromomethane<br />

5. Chloroethane<br />

6. Trichlorofluoromethane<br />

7. 1, 1-Dichloroethene<br />

8. Methylene Chloride<br />

9. Freon ® 113<br />

10. trans-1, 2-Dichloroethene<br />

11. Methyl-tert-Butyl-Ether<br />

12. 1, 1-Dichloroethane<br />

13. cis-1, 2-Dichloroethene<br />

14. Bromochloromethane<br />

15. Chloroform<br />

16. 2, 2-Dichloropropane<br />

17. 1, 2-Dichloroethane<br />

18. 1, 1, 1-Trichloroethane<br />

19. 1, 1-Dichloropropene<br />

20. Carbon Tetrachloride<br />

21. Benzene<br />

22. Fluorobenzene<br />

23. Dibromomethane<br />

24. 1, 2-Dichloropropane<br />

25. Trichloroethene<br />

26. Bromodichloromethane<br />

27. 2-Chloroethylvinylether<br />

28. cis-1, 3-Dichloropropene<br />

29. trans-1, 3-Dichloropropene<br />

30. 1, 1, 2-Trichloroethane<br />

10<br />

13<br />

11<br />

31. Toluene<br />

32. 1, 3-Dichloropropane<br />

33. Dibromochloromethane<br />

34. 1, 2-Dibromoethane<br />

35. Tetrachloroethene<br />

36. 1, 1, 1, 2-Tetrachloroethane<br />

37. Chlorobenzene<br />

38. Ethyl Benzene<br />

39. m-Xylene<br />

40. p-Xylene<br />

41. Bromoform<br />

42. Styrene<br />

43. 1, 4-Dichlorobutane<br />

44. 1,1, 2, 2-Tetrachloroethane<br />

45. o-Xylene<br />

46. 1, 2, 3-Trichloropropane<br />

47. Isopropyl Benzene<br />

48. Bromobenzene<br />

49. n-Propyl Benzene<br />

50. 2-Chlorotoluene<br />

51. 4-Chlorotoluene<br />

52. 1, 3, 5-Trimethylbenzene<br />

53. tert-Butylbenzene<br />

54. 1, 2, 4-Trimethylbenzene<br />

55. sec-Butylbenzene<br />

56. 1, 3-Dichlorobenzene<br />

57. 1, 4-Dichlorobenzene<br />

58. p-Isopropyl Toluene<br />

59. 1, 2-Dichlorobenzene<br />

60. n-Butylbenzene<br />

19<br />

21<br />

22 25 27 28 29<br />

5 10 15 20 25<br />

31<br />

35<br />

61. 1, 2-Bromo-3-Chloropropane<br />

62. 4-Bromo-1-Chlorobenzene<br />

63. 1, 2, 4-Trichlorobenzene<br />

64. Naphthalene<br />

65. Hexachlorobutadiene<br />

66. 1, 2, 3-Trichlorobenzene<br />

63 64<br />

66<br />

65<br />

ELCD<br />

TIME (MIN.)<br />

7<br />

3<br />

5<br />

1 2 6<br />

4<br />

37<br />

38<br />

39/40<br />

42<br />

45<br />

47<br />

48<br />

51<br />

50<br />

49<br />

52<br />

53<br />

55 56<br />

54<br />

57<br />

58 59 60<br />

22.5 25.0 27.5<br />

8<br />

9<br />

10<br />

15<br />

12<br />

13<br />

14<br />

20<br />

16 17<br />

18<br />

19<br />

enlarged<br />

view from<br />

PID<br />

22<br />

26<br />

24<br />

23<br />

5 10 15 20 25<br />

25<br />

29<br />

28<br />

33<br />

27<br />

34<br />

62<br />

35 36<br />

57<br />

63<br />

66<br />

56<br />

59<br />

30<br />

32 37<br />

44<br />

50 51<br />

46<br />

43<br />

41 48<br />

62<br />

61<br />

65<br />

104


Capillary Column Applications<br />

Environmental<br />

U.S. EPA Method 8260B – Volatile Organics<br />

73-75<br />

76<br />

77,78<br />

11.5 11.6 11.7 11.8 11.9 12.0 12.1 12.2 12.3 12.4 12.5 12.6 12.7 12.8 12.9 13.0<br />

TIME (MIN.)<br />

1. Carbon Dioxide<br />

2. Dichlorodifluoromethane<br />

3. Freon ® 114<br />

4. Chloromethane<br />

5. Vinyl Chloride<br />

6. Bromomethane<br />

7. Chloroethane<br />

8. Trichlorofluoromethane<br />

9. Ethanol<br />

10. Diethyl Ether<br />

11. 1,1-Dichloroethene<br />

12. Lodomethane<br />

13. Carbon Disulfide<br />

14. Freon ® 113<br />

15. Acrolein<br />

16. Allyl Chloride<br />

17. Methylene Chloride<br />

18. Acetone<br />

19. trans-1,2-Dichloroethene<br />

20. Methyl Acetate<br />

21. Methyl tert-Butyl Eether<br />

22. tert-Butyl Alcohol<br />

79 80<br />

Column: Elite-VMS<br />

Dimensions: 40 m, 0.18 mm i.d., 1.0 μm<br />

Conc.: 5 ppb each in 25 mL of RO water<br />

Trap: Vocarb 3000<br />

Purge: 11 min. @ 40 mL/min.<br />

Dry Purge: 1 min. @ 40 mL/min. (MCS by-passed<br />

with Silcosteel ® Tubing)<br />

Desorb Preheat: 245 °C<br />

Desorb: 2 min. @ 250 °C<br />

Desorb Flow Rate: 45 mL/min. Helium<br />

Bake: 8 min. @ 260 °C<br />

Interface: Plumbed through injection port<br />

Part No.<br />

N9316651<br />

81<br />

82<br />

83<br />

2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0 10.0 11.0 12.0 13.0 14.0 15.0<br />

TIME (MIN.)<br />

23. Acetonitrile<br />

24. Diisopropyl Ether<br />

25. Chloroprene<br />

26. 1,1-Dichloroethane<br />

27. Acrylonitrile<br />

28. Vinyl Acetate**<br />

29. Ethyl-tert-Butyl Ether**<br />

30. cis-1, 2-Dichloroethene<br />

31. 2, 2-Dichloropropane<br />

32. Bromochloromethane<br />

33. Chloroform<br />

34. Carbon Tetrachloride<br />

35. Ethyl Acetate<br />

36. Methyl Acrylate<br />

37. Dibromofluoromethane<br />

38. Tetrahydrofuran<br />

39. 1,1,1-Trichloroethane<br />

40. 2-Butanone<br />

41. 1,1-Dichloropropene<br />

42. Benzene<br />

43. Propionitrile<br />

44. Methacrylonitrile<br />

45. Pentafluorobenzene<br />

46. tert-Amyl-Methyl Ether<br />

47. 1, 2-Dichloroethane<br />

48. Isobutyl Alcohol<br />

49. Isopropyl Acetate<br />

50. Trichloroethene<br />

51. 1, 4-Difluorobenzene<br />

52. Dibromomethane<br />

53. 1, 2-Dichloropropane<br />

54. Bromodichloromethane<br />

55. Methyl Methacrylate<br />

56. n-Propyl Acetate<br />

57. 2-Chloroethyl Vinyl Ether<br />

58. cis-1, 3-Dichloropropene<br />

59. Toluene-d8<br />

60. Toluene<br />

61. 2-Nitropropane<br />

62. Tetrachloroethene<br />

63. 4-Methyl-2-Pentanone<br />

64. trans-1, 3-Dichloropropene<br />

65. 2-Bromo-1-Chloropropane<br />

66. 1,1, 2-Trichloroethane<br />

* 2-Chloroethanol in 8260B mix requires lower scan range for identification;<br />

1, 4-Dioxane requires fortification or identification using single-point high-calibration standard.<br />

** Peaks 28 & 29 share ion (43).<br />

84<br />

86-89<br />

85<br />

90-92<br />

93<br />

94<br />

96,97<br />

95<br />

98 99 100<br />

101,102<br />

103<br />

60<br />

59<br />

49 50 58 6972<br />

45<br />

42,43 51<br />

28,29 35-38 46 54 53<br />

40,41<br />

55 57 68 71<br />

70<br />

1<br />

11-13<br />

2 3 5 4<br />

6 7 8 16 17 21<br />

19 20 24 25,26<br />

44<br />

30 31 33 39<br />

47 52 56<br />

10<br />

32 34<br />

14 18<br />

61<br />

9 15 22 23 27<br />

48<br />

104<br />

Transfer Line: Silcosteel ® transfer line<br />

Mount Temperature: 40 °C<br />

Split Ratio: 1:40 split<br />

Injector: 250 °C<br />

Carrier Gas: 1.1 mL/min. Helium, constant flow<br />

Linear Velocity: 32 cm/sec. @ 40 °C<br />

Oven: 35 °C (hold 2 min.) to 60 °C @ 4 °C/min.<br />

(hold 0 min.) to 225 °C @ 40 °C/min.<br />

(hold 5 min.)<br />

Source Temperature: 280 °C<br />

Scan Range: 35–260 amu<br />

Ionization: EI<br />

62-64<br />

66,67<br />

65<br />

67. Ethyl Methacrylate<br />

68. Dibromochloromethane<br />

69. 1, 3-Dichloropropane<br />

70. 1, 2-Dibromoethane<br />

71. n-Butyl Acetate<br />

72. 2-Hexanone<br />

73. Chlorobenzene-d5<br />

74. Chlorobenzene<br />

75. Ethylbenzene<br />

76. 1,1,1, 2-Tetrachloroethane<br />

77. m-Xylene<br />

78. p-Xylene<br />

79. o-Xylene<br />

80. Styrene<br />

81. Bromoform<br />

82. Isopropylbenzene<br />

83. n-Amyl Acetate<br />

84. 4-Bromo-1-Fluorobenzene (ss)<br />

85. cis-1,4-Dichloro-2-Butene<br />

86. n-Propylbenzene<br />

87. Bromobenzene<br />

88. 1, 4-Dichlorobutane<br />

108<br />

106,107 109 110<br />

105<br />

89. 1,1, 2, 2-Tetrachloroethane<br />

90. 2-Chlorotoluene<br />

91. 1, 3, 5-Trimethylbenzene<br />

92. 1, 2, 3-Trichloropropane<br />

93. trans-1, 4-Dichloro-2-Butene<br />

94. 4-Chlorotoluene<br />

95. tert-Butylbenzene<br />

96. Pentachloroethane<br />

97. 1, 2, 4-Trimethylbenzene<br />

98. sec-Butylbenzene<br />

99. p-Isopropyltoluene<br />

100. 1, 3-Dichlorobenzene<br />

101. 1, 4-Dichlorobenzene-d4<br />

102. 1, 4-Dichlorobenzene<br />

103. n-Butylbenzene<br />

104. 1, 2-Dichlorobenzene<br />

105. 1, 2-Dibromo-3-Chloropropane<br />

106. Nitrobenzene<br />

107. Hexachlorobutadiene<br />

108. 1, 2, 4-Trichlorobenzene<br />

109. Naphthalene<br />

110. 1, 2, 3-Trichlorobenzene<br />

Capillary Column Applications Gas Chromatography<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

105


Capillary Column Applications<br />

Environmental<br />

Gas Chromatography Capillary Column Applications<br />

U.S. EPA Method 8260B – Volatile Organics<br />

Column: Elite-Volatiles<br />

Dimensions: 30 m, 0.25 mm i.d., 1.40 μm<br />

Conc.: TurboMatrix 110 Headspace Trap<br />

Trap: Air Monitoring<br />

Thermostating Time: 80 °C<br />

Needle Temperature: 90 °C<br />

Dry Purge: 5 min.<br />

Desorb Temperature: 280 °C<br />

Desorb Time: 0.5 min.<br />

Oven Temperature: 40 °C (hold 2 min.) to 100 °C @ 10 °C/min. (hold 0 min.)<br />

to 240 °C @ 30 °C/min. (hold 5 min.)<br />

Carrier Gas: Helium at 1 mL/min.<br />

Detector: MS<br />

Scan Time: 0.10 sec.<br />

Transfer Line Temperature: 200 °C<br />

Source Temperature: 200 °C<br />

Trap Emission: 75 μA<br />

Part No.<br />

N9316388<br />

1. Dichlorodifluoromethane<br />

2. Chloromethane<br />

3. Vinyl Chloride<br />

4. Bromomethane<br />

5. Chloroethane<br />

6. Trichlorofluoromethane<br />

7. Ethanol (2500 ppb)<br />

8. 1,1-Dichloroethene<br />

9. Carbon Disulfide (40 ppb)<br />

10. Allyl Chloride<br />

11. Methylene Chloride<br />

12. Acetone<br />

13. trans-1, 2-Dichloroethene<br />

14. Methyl tert-Butyl Ether<br />

15. tert-Butyl Alcohol (100 ppb)<br />

16. Disopropyl Ether<br />

17. 1,1-Dichloroethane<br />

18. Acrylonitrile<br />

19. Vinyl Acetate<br />

20. Allyl Alcohol (250 ppb)<br />

21. Ethyl-tert-Buyl Ether<br />

22. cis-1, 2-Dichloroethene<br />

23. 2, 2-Dichloropropane<br />

24. Bromochloromethane<br />

25. Chloroform<br />

26. Ethyl Acetate<br />

27. Carbon Tetrachloride<br />

28. Methyl Acrylate<br />

29. Propargyl Alcohol (500 ppb)<br />

30. Dibromofluoromethane (SMC)<br />

31. Tetrahydrofuran<br />

32. 1,1,1-Trichloroethane<br />

33. 2-Butanone<br />

34. 1,1-Dichloropropene<br />

35. Benzene<br />

36. Pentafluorobenzene (IS)<br />

37. tert-Amyl-Methyl Ether<br />

38. 1, 2-Dichloroethane<br />

39. Isobutyl Alcohol (500 ppb)<br />

40. Isopropyl Acetate<br />

41. Trichloroethene<br />

42. 1, 4-Difluorobenzene (SMC)<br />

43. Dibromomethane<br />

44. 1, 2-Dichloropropane<br />

45. Bromodichloromethane<br />

46. Methyl Methacrylate<br />

47. n-Propyl Acetate<br />

48. 2-Chloroethanol (2500 ppb)<br />

49. cis-1, 3-Dichloropropene<br />

50. Toluene-d8 (SMC)<br />

TIME (MIN.)<br />

51. Toluene<br />

52. Pyridine (250 ppb)<br />

53. Tetrachloroethene<br />

54. 4-Methyl-2-Pentanone<br />

55. trans-1, 3-Dichloropropene<br />

56. 1,1, 2-Trichloroethane<br />

57. Ethyl Methacrylate<br />

58. Dibromochloromethane<br />

59. 1, 3-Dichloropropane<br />

60. 1, 2-Dibromoethane<br />

61. n-Butyl Acetate<br />

62. 2-Hexanone<br />

63. 2-Picoline (250 ppb)<br />

64. Chlorobenzene-D5 (IS)<br />

65. Chlorobenzene<br />

66. Ethylbenzene<br />

67. 1,1,1, 2-Tetrachloroethane<br />

68. m-Xylene<br />

69. p-Xylene<br />

70. o-Xylene<br />

71. Stryrene<br />

72. Bromoform<br />

73. Isopropylbenzene<br />

74. 4-Bromo-1-Fluorobenzene (SMC)<br />

75. Bromobenzene<br />

76. n-Propylbenzene<br />

77. 1,1, 2, 2-Tetrachloroethane<br />

78. 2-Chlorotoluene<br />

79. 1, 3, 5-Trimethylbenzene<br />

80. 1, 2, 3-Trichloropropane<br />

81. 4-Chlorotoluene<br />

82. tert-Butylbenzene<br />

83. Pentachloroethane<br />

84. 1, 2, 4-Trimethylbenzene<br />

85. sec-Butylbenzene<br />

86. p-Isopropyltoluene<br />

87. 1, 3-Dichlorobenzene<br />

88. 1, 4-Dichlorobenzene-d4 (IS)<br />

89. 1, 4-Dichlorobenzene<br />

90. n-Butylbenzene<br />

91. 1, 2-Dichlorobenzene<br />

92. 1, 2-Dibromo-3-Chloropropane<br />

93. Nitrobenzene (250 ppb)<br />

94. Hexachlorobutadiene<br />

95. 1, 2, 4-Trichlorobenzene<br />

96. Naphthalene<br />

97. 1, 2, 3-Trichlorobenzene<br />

106


Capillary Column Applications<br />

Environmental<br />

U.S. EPA Method 8270 – Semi-Volatile Organics<br />

6,7<br />

1,2<br />

8<br />

10,11<br />

1. n-Nitrosodimethylamine<br />

2. Pyridine<br />

3. Methyl Methanesulfonate<br />

4. 2-Fluorophenol<br />

5. Ethyl Methanesulfonate<br />

6. Phenol-d6<br />

7. Phenol<br />

8. Aniline<br />

9. Bis(2-chloroethyl)ether<br />

10. 2-Chlorophenol-d4<br />

11. 2-Chlorophenol<br />

12. 1, 3-Dichlorobenzene<br />

13. 1, 4-Dichlorobenzene-d4<br />

14. 1, 4-Dichlorobenzene<br />

15. Benzyl Alcohol<br />

16. 1, 2-Dichlorobenzene-d4<br />

17. 1, 2-Dichlorobenzene<br />

18. 2-Methylphenol<br />

9<br />

3<br />

4<br />

13,14<br />

12<br />

5<br />

16,17<br />

15<br />

18<br />

19<br />

6,7<br />

10<br />

20 21,22<br />

23 24<br />

25 26<br />

27,28<br />

34<br />

29,30<br />

47<br />

31<br />

32<br />

19. Bis(2-chloroisopropyl)ether<br />

20. 4-Methylphenol/<br />

3-Methylphenol<br />

21. n-Nitroso-di-n-Propylamine<br />

22. Acetophenone<br />

23. Hexachloroethane<br />

24. Nitrobenzene-d5<br />

25. Nitrobenzene<br />

26. Isophorone<br />

27. 2, 4-Dimethylphenol<br />

28. 2-Nitrophenol<br />

29. Benzoic Acid<br />

30. Bis (2-Chloroethoxy) Methane<br />

31. 2, 4-Dichlorophenol<br />

32. 1, 2, 4-Trichlorobenzene<br />

33. Naphthalene-d8<br />

34. Naphthalene<br />

35. 2, 6-Dichlorophenol<br />

33<br />

34<br />

58<br />

38<br />

67<br />

35,36<br />

37<br />

39<br />

81<br />

40<br />

82<br />

86<br />

83<br />

87,88<br />

84<br />

41 42<br />

44<br />

43<br />

85<br />

36. 4-Chloroaniline<br />

37. Hexachloropropene<br />

38. Hexachlorobutadiene<br />

39. 4-Chloro-3-Methylphenol<br />

40. Isosafrole<br />

41. 2-Methylnaphthalene<br />

42. 1-Methylnaphthalene<br />

43. Hexachlorocyclopentadiene<br />

44. 1 ,2, 4, 5-Tetrachlorobenzene<br />

45. 2, 4, 6-Trichlorophenol<br />

46. 2, 4, 5-Trichlorophenol<br />

47. 2-Fluorobiphenyl<br />

48. Safrole<br />

49. 2-Chloronaphthalene<br />

50. 2-Nitroaniline<br />

51. 1, 4-Naphthoquinone<br />

52. Dimethylphthalate<br />

53. 1, 3-Dinitrobenzene<br />

45<br />

47<br />

46<br />

89<br />

90 91<br />

95,96 97<br />

98<br />

48<br />

49<br />

92<br />

94<br />

93<br />

5051 52 53<br />

54<br />

55<br />

59<br />

57<br />

58<br />

60<br />

54. 2, 6-Dinitrotoluene<br />

55. Acenaphthylene<br />

56. 3-Nitroaniline<br />

57. Acenaphthene-d10<br />

58. Acenaphthene<br />

59. 2, 4-Dinitrophenol<br />

60. 4-Nitrophenol<br />

61. Pentachlorobenzene<br />

62. 2,4-Dinitrotoluene<br />

63. Dibenzofuran<br />

64. 2, 3, 4, 6-Tetrachlorophenol<br />

65. Diethyl Phthalate<br />

66. 4-Chlorophenyl Phenyl Ether<br />

67. Fluorene<br />

68. 4-Nitroaniline<br />

69. 4,6-Dinitro-2-Methylphenol<br />

70. Diphenylamine<br />

71. Azobenzene<br />

61<br />

99 100 101<br />

102<br />

103<br />

62,63<br />

64<br />

66<br />

65<br />

67 68,69<br />

70 71 72<br />

72. 2, 4, 6-Tribromophenol<br />

73. Phenacetin<br />

74. 4-Bromophenyl-Phenyl ether<br />

75. Hexachlorobenzene<br />

76. Pentachlorophenol<br />

77. Pentachloronitrobenzene<br />

78. Dinoseb<br />

79. Phenanthrene-d10<br />

80. Phenanthrene<br />

81. Anthracene<br />

82. Di-n-Butylphthalate<br />

83. 4-Nitroquinoline-1-Oxide<br />

84. Isodrin<br />

85. Fluoranthene<br />

86. Benzidine<br />

87. Pyrene<br />

88. Aromite<br />

89. p-Terphenyl-d14<br />

104,105 106<br />

4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24<br />

80 81<br />

74 75<br />

73 77<br />

79<br />

76<br />

78<br />

7.0 7.5 8.0 8.5 9.0 9.5 10.0 10.5 11.0 11.5 12.0 12.5<br />

TIME (MIN.)<br />

Column: Elite-5 ms<br />

Dimensions: 30 m, 0.25 mm i.d., 0.5 μm<br />

Sample: 80 ng splitless injection of CLP standard<br />

Oven: 40 °C (hold 2 min.) to 290 °C at 20 °C/min.<br />

(hold 0 min.) to 303 °C at 2 °C/min. (hold<br />

0 min.) to 330 °C at 6 °C/min. (hold 1 min.)<br />

Injector: 300 °C<br />

Detector: MS, 280 °C, scan range 35-550 AMU<br />

Carrier: Helium at 1.0 mL/min.<br />

Part No.<br />

N9316284<br />

90. Chlorbenzilate<br />

91. Butyl Benzyl Phthalate<br />

92. Kepone<br />

93. Bis(2-ethylhexyl)phthalate<br />

94. 3, 3'-Dichlorobenzidine<br />

95. Benzo (a) Anthracene<br />

96. Chrysene-d12<br />

97. Chrysene<br />

98. Di-n-Octyl Phthalate<br />

99. Benzo (k) Fluoranthene<br />

100. Benzo (b) Fluoranthene<br />

101. Benzo (a) Pyrene<br />

102. Perylene-d12<br />

103. 3-Methylcholanthrene<br />

104. Indeno (1, 2, 3-cd) Pyrene<br />

105. Dibenzo (a, h) Snthracene<br />

106. Benzo (g, h ,i) Perylene<br />

Capillary Column Applications Gas Chromatography<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

107


Capillary Column Applications<br />

Environmental<br />

Gas Chromatography Capillary Column Applications<br />

<strong>Essential</strong> Oils – Citronella Java Oil<br />

1. Limonene<br />

2. Citronellal<br />

3. Linalool<br />

4. Borneol<br />

5. γ-Elemene<br />

6. β-Caryophyllene<br />

7. Neryl Acetate<br />

8. α-Terpineol<br />

9. Germancrene-Δ<br />

10. β-Citronellol<br />

11. Geranyl Acetate<br />

12. δ-Cadenene<br />

13. Nerol<br />

14. Geraniol<br />

15. Eugenol<br />

16. α-Bergamotene<br />

1<br />

3<br />

2<br />

4<br />

8<br />

10<br />

13<br />

14<br />

15<br />

7<br />

11<br />

5<br />

TIME (MIN.)<br />

6<br />

Column: Elite-1<br />

Dimensions: 60 m, 0.25 mm i.d., 0.25 μm<br />

Sample: 1.0 μL split injection of Citronella Java Oil<br />

Oven: 100 °C to 260 °C at 4 °C/min. (hold 1 min.)<br />

Injector: 250 °C<br />

Detector: MS, 280 °C<br />

Carrier: Helium at 30 cm/sec.<br />

Split Vent: 100 cc/min.<br />

Part No.<br />

9<br />

12<br />

16<br />

N9316013<br />

6 8 10 12 14 16 18 20 22 24 26 28<br />

Nitrogen Containing Herbicides<br />

1. Eptam ®<br />

2. Sutan ®<br />

3. Vernam ®<br />

4. Tillam ®<br />

5. Ordram ®<br />

6. Propachlor<br />

7. Ro-Neet ®<br />

8. Treflan ®<br />

9. Balan ®<br />

10. Simazine<br />

11. Atrazine<br />

1<br />

12. Propazine<br />

13. Tolban ®<br />

14. Terbacil<br />

15. Sencor ®<br />

16. Bromacil<br />

17. Dual ®<br />

18. Paarlan ®<br />

19. Prowl ®<br />

20. Oxadiazon<br />

21. GOAL ®<br />

22. Hexazinone<br />

2<br />

3<br />

4<br />

5<br />

6 7<br />

2 4 6 8 10 12 14 16 18<br />

TIME (MIN.)<br />

9<br />

8<br />

12<br />

11<br />

10<br />

13<br />

15<br />

14<br />

16<br />

17 19<br />

18<br />

Column: Elite-5<br />

Dimensions: 30 m, 0.53 mm i.d., 5.0 μm<br />

Sample: 0.2 μL direct injection of nitrogen containing herbicides.<br />

Concentration approximately 10 ng per component.<br />

Oven Temperature: 60 °C (hold 1 min.) to 290 °C @ 15 °C/min.<br />

(hold 5 min.)<br />

Injector: 290 °C<br />

Detector: FID, 290 °C<br />

Carrier Gas: Helium @ 40 cm/sec.<br />

Part No.<br />

20 21<br />

22<br />

N9316102<br />

108


Capillary Column Applications<br />

Environmental<br />

Pesticides<br />

1. Tetrachloro-m-xylene<br />

2. a-BHC<br />

3. g-BHC<br />

4. Heptachlor<br />

5. Aldrin<br />

6. b-BHC<br />

7. d-BHC<br />

8. Heptachlor Epoxide<br />

Synthetic <strong>Essential</strong> Oil Mixture<br />

3,4<br />

20,21<br />

14<br />

27<br />

19<br />

23,24<br />

18<br />

6,7 15<br />

28<br />

22<br />

2<br />

16<br />

1 5 25<br />

8<br />

11,12<br />

10 9 13 26<br />

17<br />

9. Endosulfan I<br />

10. g-Chlordane<br />

11. a-Chlordane<br />

12. P, P'-DDE<br />

13. Dieldrin<br />

14. Endrin<br />

15. P, P'-DDD<br />

16. Endosulfan II<br />

Column: Elite-5<br />

Dimensions: 30 m, 0.53 mm i.d., 5.0 μm<br />

Sample: 1.0 μL direct injection of a pesticide mix.<br />

Concentration: 80-800 ppb (ng/mL)<br />

Oven Temperature: 150 °C (hold 5 min.) to 275 °C<br />

@ 4 °C/min. (hold 5 min.)<br />

Injector: 200 °C<br />

Detector: ECD, 275 °C<br />

Carrier Gas: Helium @ 40 cm/sec.<br />

Part No.<br />

N9316102<br />

29 31<br />

30<br />

35<br />

32,33<br />

34<br />

36<br />

37<br />

38<br />

10 15 20 25 30<br />

TIME (MIN.)<br />

39<br />

1<br />

40<br />

17. P, P'-DDT<br />

18. Endrin Aldehyde<br />

19. Endosulfan Sulfate<br />

20. Methoxychlor<br />

21. Endrin Ketone<br />

22. Decachlorobiphenyl<br />

41<br />

2 3<br />

6<br />

7 4<br />

42<br />

5 8<br />

9<br />

10 11<br />

TIME (MIN.)<br />

13 12 14<br />

16<br />

17<br />

19<br />

15<br />

18<br />

10 20 30<br />

1. Ethyl Butyrate<br />

2. trans-2-Hexenol<br />

3. α-Pinene<br />

4. Benzaldehyde<br />

5. Camphene<br />

6. Octanol<br />

7. β-Myrcene<br />

8. β-Pinene<br />

9. α-Phellandrene<br />

10. p-Cymene<br />

11. l-Limonene<br />

12. Camphor<br />

13. trans-Sabinene Hydrate<br />

14. Linalool<br />

15. Citronellal<br />

16. l-Menthone<br />

17. Menthofuran<br />

18. l-Menthol<br />

19. α-Terpineol<br />

20. Linalyl Acetate<br />

21. β-Citronellol<br />

22. Nerol<br />

23. Carveol<br />

24. Anisaldehyde<br />

25. Carvone<br />

26. Geraniol<br />

27. Anethole<br />

28. Cinnamic Alcohol<br />

29. Eugenol<br />

30. Neryl Acetate<br />

31. Geranyl Acetate<br />

32. Vanillin<br />

33. Coumarin<br />

34. α-Ionone<br />

35. Ethyl Vanillin<br />

36. β-Caryophyllene<br />

37. α-Caryophyllene<br />

38. β-Ionone<br />

39. Valencene<br />

40. Ethyl Laurate<br />

41. Amyl Cinnamic Aldehyde<br />

42. Nootketone<br />

Column: Elite-1<br />

Dimensions: 60 m, 0.25 mm i.d., 0.25 μm<br />

Sample: 1.0 μL split injection of 42 flavor components<br />

Oven: 100 °C to 260 °C at 4 °C/min. (hold 1 min.)<br />

Injector: 250 °C<br />

Detector: 280 °C<br />

Carrier: Helium at 30 cm/sec.<br />

Split Vent: 100 cc/min.<br />

Part No.<br />

21<br />

N9316013<br />

20<br />

22<br />

Capillary Column Applications Gas Chromatography<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

109


Capillary Column Applications<br />

Food and Flavors<br />

Gas Chromatography Capillary Column Applications<br />

180<br />

160<br />

140<br />

120<br />

100<br />

80<br />

60<br />

40<br />

20<br />

Brewing – Beer<br />

1. Chloroform<br />

2. 2, 3-Butanedione (Diacetyl)<br />

3. 2, 3-Pentanedione<br />

1<br />

2<br />

0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 2.6 2.8 3.0 3.2 3.4 3.6 3.8<br />

TIME (MIN.)<br />

<strong>Essential</strong> Oils – Lemon Oil<br />

2 3 5<br />

6<br />

7,8<br />

13<br />

12<br />

14 15<br />

17<br />

26<br />

TIME (MIN.)<br />

3<br />

Column: Elite BAC-1<br />

Dimensions: 30 m x 0.32 mm x 1.8 μm<br />

Instrument: Headspace TurboMatrix 40<br />

Table 2: HS Conditions<br />

Sample Temperature: 60 °C<br />

Needle Temperature: 80 °C<br />

Transfer Line Temperature: 100 °C<br />

Equilibration Time: 15 min.<br />

Pressurization Time: 1.0 min.<br />

Injection Time: 0.1 min.<br />

Withdrawal Time: 0.0 min.<br />

Carrier Pressure: 35 psi<br />

Table 3: GC with ECD Conditions<br />

Initial Temperature: 45 °C<br />

Time 1: 1.3 min.<br />

Rate 1: 40 °C/min.<br />

Final Temperature: 150 °C<br />

Hold: 0.6 min<br />

Injector Temperature: 100 °C<br />

Liner: Zero Dilution<br />

Split: 25 mL/min.<br />

ECD: 150 °C<br />

ECD Attenuation: 1<br />

Makeup Gas (Argon/Methane) 30 mL/min.<br />

Part No.<br />

10<br />

4 9<br />

20<br />

11<br />

21 22<br />

27,28<br />

1819<br />

23 24 25<br />

31<br />

30<br />

34<br />

1<br />

37<br />

16<br />

2 4 6 8 10 12 14 16 18 20 22 24 26 28<br />

1. Heptanol<br />

2. α-Thujene<br />

3. α-Pinene<br />

4. Camphene<br />

5. Sabinene<br />

6. β-Pinene<br />

7. 6-Methyl-5-Hepten-2-One<br />

8. Myrcene<br />

9. Octanal<br />

10. α-Phellandrene<br />

11. 3-Carene<br />

12. α-Terpinene<br />

13. π-Cymene<br />

14. Limonene<br />

15. γ-Terpinene<br />

16. Octanol<br />

29<br />

17. Terpinolene<br />

18. Linalool<br />

19. Nonanal<br />

20. Citronellal<br />

21. Terpinen-4-ol<br />

22. α-Terpineol<br />

23. Decanol<br />

24. Octyl Acetate<br />

32<br />

33<br />

35<br />

36<br />

38<br />

25. Nerol<br />

26. Neral<br />

27. Carvone<br />

28. Geraniol<br />

29. Geranial<br />

30. Nonyl Acetate<br />

31. Citronellyl Acetate<br />

32. Neryl Acetate<br />

N9316579<br />

Column: Elite-5<br />

Dimensions: 30 m, 0.32 mm i.d., 0.25 μm<br />

Sample: Wet needle split injection of<br />

a neat lemon oil<br />

Oven: 75 °C (hold 8 min.) to 250 °C<br />

at 4 °C/min.<br />

Injector: 250 °C<br />

Detector: FID, 250 °C<br />

Carrier: Hydrogen at 40 cm/sec.<br />

Split Ratio: 100:1<br />

Part No.<br />

N9316086<br />

33. Geranyl Acetate<br />

34. Dodecanal<br />

35. β-Caryophyllene<br />

36. trans-α-Bergamotene<br />

37. α-Humulene<br />

38. β-Bisabolene<br />

110


Capillary Column Applications<br />

Food and Flavors<br />

<strong>Essential</strong> Oils – Native Spearmint Oil<br />

1 2<br />

1. α-Pinene<br />

2. β-Pinene<br />

3. Sabinene<br />

4. Myrcene<br />

5. α-Terpinene<br />

6. L-Limonene<br />

<strong>Essential</strong> Oils – Synthetic Mushroom Aroma<br />

1. Acetone<br />

2. Ethyl Acetate<br />

3. Methylene Chloride<br />

4. Hexanal<br />

5. Amyl Acetate<br />

6. 1-Butanol<br />

7. 3-Methyl-1-Butanol<br />

8. 1-Pentanol<br />

9. 3-Octanone<br />

10. 3-Octanol<br />

11. Nonanal<br />

12. 1-Octen-3-ol<br />

13. Furfural<br />

14. Benzaldehyde<br />

15. Octyl Alcohol<br />

16. Phenylacetaldehyde<br />

17. α-Terpineol<br />

18. 2, 4-Nonadienal<br />

19. 2, 4-Decadienal<br />

20. Benzyl Alcohol<br />

3<br />

4 67<br />

5<br />

13<br />

12<br />

9<br />

8<br />

10 11<br />

1<br />

2<br />

3<br />

14<br />

15<br />

16<br />

4<br />

17<br />

5<br />

6<br />

18<br />

19<br />

20<br />

7<br />

21<br />

22<br />

8<br />

9<br />

23<br />

24<br />

26 27 28<br />

4 6 8 10 12 14 16 18 20 22 24 26 28 30 32<br />

TIME (MIN.)<br />

7. 1, 8-Cineole<br />

8. cis-Ocimene<br />

9. γ-Terpinene<br />

10. p-Cymene<br />

11. Terpinolene<br />

12. 3-Octyl Acetate<br />

25<br />

13. 3-Octanol<br />

14. L-Menthone<br />

15. trans-Sabinenehydrate<br />

16. β-Bourbonene<br />

17. Linalool<br />

18. Terpinene-4-ol<br />

10<br />

11<br />

12<br />

2 4 6 8 10 12 14 16 18 20 22 24 26 28 30<br />

TIME (MIN.)<br />

29<br />

13<br />

Column: Elite-WAX ETR<br />

Dimensions: 60 m, 0.25 mm i.d., 0.25 μm<br />

Sample: 0.2 μL split injection of a neat spearmint oil<br />

Oven: 75 °C (hold 4 min.) to 200 °C at<br />

4 °C/min. (hold 10 min.)<br />

Injector: 250 °C<br />

Detector: FID, 250 °C<br />

Carrier: Hydrogen at 40 cm/sec.<br />

Split Ratio: 100:1<br />

30<br />

19. β-Caryophyllene<br />

20. Dihydrocarvone<br />

21. trans-Dihydrocarvyl Acetate<br />

22. trans-β-Farnesene<br />

23. α-Terpineol<br />

24. Germacrene-Δ<br />

14<br />

15<br />

16<br />

Column: Elite-WAX ETR<br />

Dimensions: 30 m, 0.32 mm i.d., 1.0 μm<br />

Sample: 1.0 μL split injection of a synthetic mushroom aroma,<br />

concentration 10 ng per component<br />

Oven: 40 °C to 220 °C at 6 °C/min.<br />

Injector: 260 °C<br />

Detector: FID, 260 °C<br />

Carrier: Hydrogen at 40 cm/sec.<br />

Split Ratio: 100:1<br />

Part No.<br />

Part No.<br />

N9316557<br />

17<br />

18<br />

N9316551<br />

25. Carvone<br />

26. cis-Carvyl Acetate<br />

27. trans-Carveol<br />

28. cis-Carveol<br />

29. cis-Jasmone<br />

30. Viridiflorol<br />

19<br />

20<br />

Capillary Column Applications Gas Chromatography<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

111


Capillary Column Applications<br />

Food and Flavors<br />

Gas Chromatography Capillary Column Applications<br />

Sugars – As Alditol Acetates<br />

TCA in Wine<br />

TCA 12127<br />

100<br />

%<br />

0<br />

2<br />

1<br />

4<br />

3<br />

TIME (MIN.)<br />

78<br />

5 6<br />

2.5 5 7.5 10 12.5<br />

1. Natural Wine Separation Products<br />

2. TCA<br />

1<br />

1<br />

2<br />

SIR of 2 Channels El+<br />

TIC<br />

35166<br />

1<br />

1<br />

1<br />

1. Rhamnitol<br />

2. Fucitol<br />

3. Ribitol<br />

4. Arabinitol<br />

5. Mannitol<br />

6. Galactitol<br />

7. Glucitol<br />

8. Inositol<br />

Column: Elite-225<br />

Dimensions: 15 m, 0.25 mm i.d., 0.25 μm<br />

Sample: 0.5 μL split injection of alditol<br />

acetate derivatives<br />

Oven: 190 °C (hold 5 min.) to 250 °C<br />

at 8 °C/min. (hold 5 min.)<br />

Injector: 260 °C<br />

Detector: 260 °C<br />

Carrier: Helium at 42 cm/sec.<br />

Split Ratio: 50:1<br />

Part No.<br />

N9316175<br />

Column: Elite-5ms<br />

Dimensions: 30 m x 0.25 mm x 0.25 μm<br />

Instrument: Clarus 500 GC/MS<br />

Oven: 50 °C (hold 4 min.) to 240 °C at<br />

40 °C/min. (hold 5 min.)<br />

Injector: 150 °C<br />

Carrier: Helium (99.999%)<br />

Instrument: TurboMatrix Headspace<br />

HS-40 Trap<br />

Needle Temperature: 75 °C<br />

Transfer Line Temperature: 75 °C<br />

Oven Temperature: 75 °C<br />

Trap Low Temperature: 40 °C<br />

Trap High Temperature: 280 °C<br />

Dry Purge Time: 5 min.<br />

Trap Hold Time: 5 min.<br />

Desorb Pressure Time: 0 min.<br />

Thermostatting Time: 30 min.<br />

Pressurization: 1 min., 3 cycles<br />

Decay Time: 1.2 min.<br />

Vial Pressure: 40 psi<br />

Column Pressure: 25 psi<br />

Trap Sorbent: CarboPack Y<br />

Part No.<br />

4.49 4.69 4.89 5.09 5.29 5.49 5.69 5.89 6.09 6.29 6.49 6.69 6.89 7.09 7.29 7.49 7.69 7.89 8.09<br />

TIME (MIN.)<br />

N9316282<br />

112


Capillary Column Applications<br />

Forensics/Clinical Toxicology<br />

Anabolic Steroids – Underivatized<br />

Cannabinoids – TMS Derivatives<br />

10,11<br />

1<br />

3<br />

5 13<br />

8 14<br />

7 9<br />

6<br />

2<br />

15<br />

4<br />

12 16<br />

18<br />

17<br />

2 4 6 8 10 12 14 16 18<br />

TIME (MIN.)<br />

Column: Elite-5<br />

Dimensions: 15 m, 0.25 mm i.d., 0.25 μm<br />

Sample: 1.0 μL splitless injection of cannabinoids,<br />

concentration 100 μg/mL<br />

Oven: 50 °C (hold 0.5 min.) to 225 °C at 30 °C/min.,<br />

to 325 °C at 10 °C/min.<br />

Injector: 225 °C<br />

Detector: MS, 320 °C<br />

Carrier: Helium at 40 cm/sec.<br />

Splitless Hold Time: 0.75 min.<br />

Scan Range: 40-500 AMU<br />

Part No.<br />

N9316073<br />

1. Cannabidiol<br />

2. Δ 8 -Tetrahydrocannabinol<br />

3. Δ 9 -Tetrahydrocannabinol<br />

4. Cannibinol<br />

5. 11-Hydroxy-Δ 9 -Tetrahydrocannabinol<br />

6. 11-Nor-Δ 9 -Tetrahydrocannabinol Carboxylic Acid<br />

7. 11-Nor-Δ 8 -Tetrahydrocannabinol Carboxylic Acid<br />

1<br />

Column: Elite-5<br />

Dimensions: 30 m, 0.25 mm i.d., 0.10 μm<br />

Sample: 0.5 μL split injection of anabolic steroids<br />

Concentration 1000 ng/μL<br />

Oven: 180 °C to 340 °C at 10 °C/min. (hold 3 min.)<br />

Injector: 280 °C<br />

Detector: FID, 340 °C<br />

Carrier: Helium at 35 cm/sec.<br />

Split Ratio: 50:1<br />

5 6 7 8 9 10 11 12 13 14 15<br />

TIME (MIN.)<br />

19<br />

Part No.<br />

2<br />

3<br />

4<br />

N9316075<br />

1. 5-Androstene-3β,17β-diol<br />

2. 17α-Methyl-5-Androstene-3β,17β-Diol<br />

3. 5α-Androstan-17β-ol-3-One<br />

4. 19-Nortestosterone<br />

5. 17α-Methylandrostan-17β-ol-3-One<br />

6. Mesterolone<br />

7. Testosterone<br />

8. 17α-Methyltestosterone<br />

9. 1-Dehydrotestosterone<br />

10. 1-Dehydro-17α-Methyltestosterone<br />

11. Bolasterone<br />

12. Oxymethalone<br />

13. 19-Nortestosterone-17-Propionate<br />

14. Testosterone Propionate<br />

15. Fluoxymesterone<br />

16. 4-Chlorotestosterone-17-Acetate<br />

17. Testosterone-17β-Cypionate<br />

18. 1-Dehydrotestosterone Benzoate<br />

19. 1-Dehydrotestosterone Undecylenate<br />

5<br />

6<br />

7<br />

Capillary Column Applications Gas Chromatography<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

113


Capillary Column Applications<br />

Forensics/Clinical Toxicology<br />

Gas Chromatography Capillary Column Applications<br />

Blood Alcohol<br />

1<br />

Blood Alcohol<br />

1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 2.6 2.8 3.0<br />

TIME (MIN.)<br />

1<br />

2<br />

2<br />

3<br />

4<br />

3<br />

4<br />

5<br />

5<br />

6<br />

1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 2.6 2.8 3.0<br />

TIME (MIN.)<br />

6<br />

Column: Elite-BAC-1<br />

Dimensions: 30 m x 0.32 mm x 1.8 μm<br />

Sample: 1.0 mL Blood Alcohol Mix<br />

Oven: 40 °C Isothermal<br />

Injector: 200 °C<br />

Carrier: Helium<br />

Sample Equilibration Temperature: 70 °C<br />

Sample Equilibration Time: 15 min.<br />

Vial Pressure: 30 psi<br />

Vial Pressurization Time: 0.15 min.<br />

Vial Sampling Time: 0.01 min.<br />

Transfer Line: 0.32 mm i.d. FS Hydroguard TM Tubing (N9301357)<br />

Transfer Line Temperature: 200 °C<br />

Injection Port Sleeve: 2 mm i.d.<br />

Split Flow: 20 mL per min.<br />

Part No.<br />

N9316579<br />

Conc. w/v<br />

1. Methanol 0.1%<br />

2. Acetaldehyde 0.2%<br />

3. Ethanol 0.2%<br />

4. Isopropanol 0.1%<br />

5. Acetone 0.01%<br />

6. n-Propanol 0.1%<br />

Column: Elite-BAC-2<br />

Dimensions: 30 m x 0.32 mm x 1.2 μm<br />

Sample: 1.0 mL Blood Alcohol Mix<br />

Oven: 40 °C Isothermal<br />

Injector: 200 °C<br />

Carrier: Helium<br />

Sample Equilibration Temperature: 70 °C<br />

Sample Equilibration Time: 15 min.<br />

Vial Pressure: 30 psi<br />

Vial Pressurization Time: 0.15 min.<br />

Vial Sampling Time: 0.01 min.<br />

Transfer Line: 0.32 mm i.d. FS Hydroguard Tubing (N9301357)<br />

Transfer Line Temperature: 200 °C<br />

Injection Port Sleeve: 2 mm i.d.<br />

Split Flow: 20 mL per min.<br />

Part No.<br />

N9316577<br />

Conc. w/v<br />

1. Methanol 0.1%<br />

2. Acetaldehyde 0.2%<br />

3. Ethanol 0.2%<br />

4. Isopropanol 0.1%<br />

5. Acetone 0.01%<br />

6. n-Propanol 0.1%<br />

114


Capillary Column Applications<br />

Forensics/Clinical Toxicology<br />

Cocaine and Metabolites<br />

2 4 6 8 10 12 14 16<br />

TIME (MIN.)<br />

Sympathomimetic Amines – HFBA Derivatives<br />

1. Amphetamine - HFBA<br />

2. Phentermine - HFBA<br />

3. Phenylpropanolamine - HFBA<br />

4. Ephedrine - HFBA<br />

5. Methamphetamine - HFBA<br />

6. Fenfluramine - HFBA<br />

7. Pseudoephedrine - HFBA<br />

8. Methylenedioxyamphetamine - HFBA<br />

9. Methylenedioxymethamphetamine - HFBA<br />

10. Methylphenidate - HFBA<br />

1<br />

2<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

5<br />

4<br />

3<br />

8<br />

1. Ecgonine Methyl Ester (TMS)<br />

2. Ecgonine (TMS)<br />

3. Cocaine<br />

4. Coca Ethylene<br />

5. Benzoylecgonine (TMS)<br />

Column: Elite-5<br />

Dimensions: 30 m, 0.25 mm i.d., 0.25 μm<br />

Sample: 1.0 μL split injection of cocaine<br />

and cocaine metabolites<br />

Oven: 150 °C to 320 °C at 10 °C/min.<br />

Injector: 250 °C<br />

Detector: FID, 300 °C<br />

Carrier: Helium at 30 cm/sec.<br />

Split Ratio: 30:1<br />

Column: Elite-5<br />

Dimensions: 30 m, 0.25 mm i.d., 0.25 μm<br />

Sample: 1.0 μL splitless injection of sympathomimetic amines<br />

Concentration approximately 2.5 ng/μL<br />

Oven: 40 °C (hold 1 min.) to 150 °C at 30 °C/min., to 300 °C at 5 °C/min.<br />

Injector: 225 °C<br />

Detector: MS, 275 °C<br />

Carrier: Helium at 20 cm/sec.<br />

Splitless Hold Time: 1 min.<br />

Part No.<br />

4 6 8 10 12 14 16 18<br />

TIME (MIN.)<br />

9<br />

N9316076<br />

Part No.<br />

10<br />

N9316076<br />

Capillary Column Applications Gas Chromatography<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

115


Capillary Column Applications<br />

Industrial Chemicals<br />

Gas Chromatography Capillary Column Applications<br />

Alcohols and Aldehydes<br />

Column: Elite-WAX ETR<br />

Dimensions: 60 m, 0.53 mm i.d., 1.0 μm<br />

Sample: 1.0 μL split injection of alcohols<br />

and aldehydes<br />

Oven: 45 °C (hold 10 min.) to 250 °C<br />

at 12 °C/min. (hold 20 min.)<br />

Injector: 250 °C<br />

Detector: MS, 285 °C<br />

Carrier: Helium at 50 cm/sec.<br />

Split Ratio: 7:1<br />

Part No.<br />

1<br />

2<br />

Alcohol Mixtures<br />

Column: Elite-WAX ETR<br />

Dimensions: 60 m, 0.53 mm i.d., 1.0 μm<br />

Sample: 1.0 μL split injection of alcohols<br />

Oven: 45 °C (hold 10 min.) to 250 °C<br />

at 12 °C/min. (hold 20 min.)<br />

Injector: 250 °C<br />

Detector: MS (EI), 250 °C<br />

Carrier: Helium at 51 cm/sec.<br />

Split Ratio: 8:1<br />

Part No.<br />

2<br />

3<br />

1<br />

3<br />

1. Pentane<br />

2. Hexane<br />

3. Heptane<br />

4. Ethanol<br />

5. Decane<br />

6. 1-Propanol<br />

N9316571<br />

4<br />

4<br />

N9316571<br />

5<br />

6<br />

7<br />

5 10 15 20 25<br />

TIME (MIN.)<br />

8<br />

7. 1-Butanol<br />

8. Dodecane<br />

9. 1-Pentanol<br />

10. 1-Hexanol<br />

11. Tetradecane<br />

12. 1-Heptanol<br />

9<br />

10<br />

11<br />

12<br />

1. Pentane<br />

2. Heptane<br />

3. Acetaldehyde<br />

4. Dimethoxy Methane<br />

5. Butyraldehyde<br />

6. 3-Pentanol<br />

7. 1-Penten-3-ol<br />

8. 3-Octanol<br />

9. Cyclohexanol<br />

10. Furfural<br />

11. Pentadecane<br />

12. Benzaldehyde<br />

13. Ethylene Glycol and<br />

2-Methyl-2, 4-Pentanediol<br />

14. Furfuryl Alcohol<br />

15. Nonadecane<br />

16. 1, 4-Butanediol<br />

17. Diethylene Glycol<br />

16 18<br />

13<br />

15<br />

17<br />

14<br />

5<br />

5 10 15 20 25<br />

TIME (MIN.)<br />

13. 1-Octanol<br />

14. Hexadecane<br />

15. 1-Nonanol<br />

16. 1-Decanol<br />

17. 1-Undecanol<br />

18. 1-Dodecanol<br />

6<br />

1. Pentane<br />

2. Methanol<br />

3. 2-Methyl-2-Propanol (tert-Butylalcohol)<br />

4. 2-Methyl-3-Buten-2-ol<br />

5. 3-Buten-2-ol<br />

6. Undecane<br />

7. 2, 2-Dimethyl-1-Propanol (Neopentanol)<br />

8. 1-Penten-3-ol<br />

9. 2-Methoxyethanol<br />

10. 2, 2, 2-Trifluoroethanol<br />

1<br />

7<br />

8<br />

9<br />

10<br />

11<br />

2 3 8<br />

9<br />

10<br />

4<br />

12,13<br />

5<br />

6<br />

14<br />

7<br />

11. 2-Ethoxyethanol<br />

12. 1-Pentanol<br />

13. 2-Methyl-1-Pentanol<br />

14. 2, 2-Dimethyl-1-Pentanol<br />

15. Tetradecane<br />

16. trans-2-Hexen-1-ol<br />

17. 1-Octanol<br />

18. Ethylene Glycol<br />

19. 1-Undecanol<br />

20. 1, 4-Butanediol<br />

19<br />

15<br />

16<br />

14<br />

5 10 15 20 25<br />

TIME (MIN.)<br />

11<br />

12<br />

13<br />

15<br />

16<br />

17<br />

17<br />

18<br />

20<br />

116


Capillary Column Applications<br />

Industrial Chemicals<br />

Aldehydes<br />

1<br />

2<br />

Amines and Phenols<br />

1<br />

3<br />

3<br />

2<br />

4<br />

5<br />

6<br />

7<br />

5 10 15 20<br />

TIME (MIN.)<br />

4<br />

5<br />

6<br />

7<br />

8<br />

9<br />

10<br />

11<br />

0 2 4 6 8 10<br />

TIME (MIN.)<br />

12<br />

8<br />

13<br />

9<br />

10<br />

1. Ethanal<br />

2. Propanal<br />

3. Butenal<br />

4. Pentanal<br />

5. Hexanal<br />

6. Heptanal<br />

7. Octanal<br />

8. Nonanal<br />

9. Decanal<br />

10. Undecanal<br />

Column: Elite-WAX<br />

Dimensions: 30 m, 0.25 mm i.d., 0.50 μm<br />

Sample: Split injection of C2-C11 aldehydes mixture,<br />

on-column concentration: 250 ng<br />

Oven: 40 °C (hold 5 min.) to 200 °C at 10 °C/min.<br />

Injector: 200 °C<br />

Detector: 200 °C<br />

Carrier: Hydrogen at 35 cm/sec.<br />

Split Ratio: 100:1<br />

Part No.<br />

N9316404<br />

1. Diethylamine<br />

2. Pyridine<br />

3. Morpholine<br />

4. Phenol<br />

5. Aniline<br />

6. 2-Chlorophenol<br />

7. Diethylenetriamine<br />

8. Octylamine<br />

9. 1-Methyl-2-Pyrrolidinone<br />

10. 2-Nitrophenol<br />

11. 2, 6-Dimethylaniline<br />

12. Nicotine<br />

13. 2-Nitroaniline<br />

Column: Elite-5Amine<br />

Dimensions: 30 m, 0.32 mm i.d., 1.0 μm<br />

Sample: 1.0 μL split injection of miscellaneous<br />

amines and phenols in water<br />

On-Column Conc.: 22 ng<br />

Oven: 120° to 220 °C @ 10 °C/min.<br />

Injector: 305 °C<br />

Linear Velocity: 38 cm/sec. set @ 120 °C<br />

FID Sensitivity: 6.4 x 10-11 AFS<br />

Split Ratio: 25:1<br />

Part No.<br />

N9316677<br />

Capillary Column Applications Gas Chromatography<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

117


Capillary Column Applications<br />

Industrial Chemicals<br />

Gas Chromatography Capillary Column Applications<br />

Aromatics<br />

Column: Elite-WAX ETR<br />

Dimensions: 60 m, 0.53 mm i.d., 1.0 μm<br />

Sample: 1.0 μL split injection of an<br />

aromatics mixture<br />

Oven: 40 °C (hold 10 min.) to 245 °C<br />

at 4 °C/min. (hold 20 min.)<br />

Injector: 250 °C<br />

Detector: MS, 280 °C<br />

Carrier: Helium at 50 cm/sec.<br />

Split Ratio: 7:1<br />

Part No.<br />

N9316571<br />

Industrial Solvents<br />

1. Pentane<br />

2. Hexane<br />

3. Methyl Formate<br />

4. Acetone<br />

5. Tetrahydrofuran<br />

6. 1, 1, 1-Trichloroethane<br />

7. Ethyl Acetate<br />

8. Methanol<br />

9. Methylethyl Ketone<br />

10. Methylene Chloride<br />

11. Chloroform<br />

12. Benzene<br />

13. n-Propyl Alcohol<br />

14. sec-Butyl Alcohol<br />

15. Toluene<br />

16. n-Butyl Acetate<br />

17. Isobutyl Alcohol<br />

18. n-Butyl Alcohol<br />

19. o-Xylene<br />

20. Ethoxyethane<br />

1<br />

1. trans-Decahydronaphthalene<br />

2. 1, 2-Xylene<br />

3. cis-Decahydronaphthalene<br />

4. 1, 3, 5-Trimethylbenzene<br />

5. p-Cymene or p-Isopropyltoluene<br />

6. 1, 2, 4-Trimethylbenzene<br />

7. α-Methyl Benzene<br />

8. 1, 2, 3-Trimethylbenzene 10<br />

7<br />

8<br />

9<br />

2<br />

3<br />

4<br />

5<br />

6<br />

11<br />

TIME (MIN.)<br />

9. Diisopropylbenzene<br />

10. Triethylbenzene<br />

11. Pentadecane<br />

12. Nitrobenzene<br />

13. Nonadecane<br />

14. o-Cresol<br />

15. Bibenzyl<br />

15 20 30 35 40 45 50 55<br />

2<br />

1<br />

8,9<br />

3<br />

5<br />

4<br />

6,7 10,11 15<br />

Column: Elite-MWAX<br />

Dimensions: 30 m, 0.53 mm i.d., 1.0 μm<br />

Sample: Wet needle injection of neat solvents<br />

Oven: 50 °C to 220 °C at 10 °C/min.<br />

Injector: 250 °C<br />

Detector: FID, 250 °C<br />

Carrier: Helium at 20 cm/sec.<br />

13<br />

12<br />

14<br />

16<br />

17 18<br />

19<br />

20<br />

2 4 6 8 10<br />

TIME (MIN.)<br />

Industrial Solvents<br />

1. Pentane<br />

2. Hexane<br />

3. Methyl Formate<br />

4. Acetone<br />

5. Tetrahydrofuran<br />

6. 1, 1, 1-Trichloroethane<br />

7. Ethyl Acetate<br />

8. Methanol<br />

9. Methylethyl Ketone<br />

10. Methylene Chloride<br />

11. Chloroform<br />

12. Benzene<br />

13. n-Propyl Alcohol<br />

14. sec-Butyl Alcohol<br />

15. Toluene<br />

16. n-Butyl Acetate<br />

17. Isobutyl Alcohol<br />

18. n-Butyl Alcohol<br />

19. o-Xylene<br />

20. Ethoxyethane<br />

12<br />

1<br />

2<br />

3<br />

13<br />

6,7<br />

Column: Elite-WAX ETR<br />

Dimensions: 30 m, 0.53 mm i.d., 1.0 μm<br />

Sample: Wet needle injection of neat solvents<br />

Oven: 50 °C to 220 °C at 10 °C/min.<br />

Injector: 250 °C<br />

Detector: 250 °C<br />

Carrier: Helium at 20 cm/sec.<br />

14<br />

15<br />

10,11 15 19<br />

8,9<br />

16<br />

5<br />

14<br />

13 17<br />

4<br />

18<br />

12<br />

2 4 6 8 10<br />

TIME (MIN.)<br />

Part No. N9316478 Part No. N9316569<br />

20<br />

118


Capillary Column Applications<br />

Petroleum<br />

Prudhoe Bay Crude Oil<br />

1. Benzene<br />

2. Heptane<br />

3. Toluene<br />

4. Octane<br />

5. m-Xylene and p-Xylene<br />

6. o-Xylene<br />

7. Nonane<br />

8. Decane<br />

9. Undecane<br />

10. Dodecane<br />

1<br />

2<br />

3<br />

4<br />

Volatile Hydrocarbons<br />

5<br />

6<br />

7<br />

8<br />

9<br />

11. Tridecane<br />

12. Tetradecane<br />

13. Pentadecane<br />

14. Hexadecane<br />

15. Heptadecane<br />

16. Pristane<br />

17. Octadecane<br />

18. Phytane<br />

19. Nonadecane<br />

20. Eicosane<br />

10<br />

11<br />

12<br />

13<br />

14<br />

15<br />

16<br />

21. Heneicosane<br />

22. Docosane<br />

23. Tricosane<br />

24. Tetracosane<br />

25. Pentacosane<br />

26. Hexacosane<br />

27. Heptacosane<br />

28. Octacosane<br />

17<br />

18<br />

19<br />

20<br />

21<br />

22<br />

23<br />

Column: Elite-1<br />

Dimensions: 30 m, 0.53 mm i.d., 3.0 μm<br />

Sample: 0.4 μL split injection of Prudhoe Bay crude oil<br />

Oven: 40 °C to 285 °C at 5 °C/min. (hold 30 min.)<br />

Injector: 285 °C<br />

Detector: 285 °C<br />

Carrier: Hydrogen at 40 cm/sec.<br />

Split Ratio: 50:1<br />

4 8 12 16 20 24 28 32 36 40 44 48 52 56 60 64 68 72 76 80<br />

TIME (MIN.)<br />

1<br />

2,3<br />

4<br />

5 7<br />

6<br />

8,9<br />

13 11<br />

15<br />

12<br />

1 2 3 4 5 6 7 8 9 10 11 12 13 14<br />

TIME (MIN.)<br />

10<br />

14<br />

16<br />

17<br />

24<br />

Part No.<br />

25<br />

26<br />

N9316051<br />

27<br />

1. Methane<br />

2. Ethylene<br />

3. Acetylene<br />

4. Ethane<br />

5. Propylene<br />

6. Propane<br />

7. Cyclopropane<br />

8. Propadiene<br />

9. Propyne<br />

28<br />

10. Isobutane<br />

11. 1, 3-Butadiene<br />

12. 1-Butene<br />

13. n-Butane<br />

14. cis-2-Butene<br />

15. trans-2-Butene<br />

16. Isopentane<br />

17. n-Pentane<br />

Column: Elite-Q PLOT<br />

Dimensions: 30 m, 0.32 mm i.d.<br />

Sample: 300 μL split injection (40:1), 1000 ppm<br />

Oven: 50 °C (2 min.) to 220 °C at 15 °C/min.<br />

Injector: 250 °C<br />

Detector: FID, 250 °C<br />

Carrier: Helium at 42 cm/sec.<br />

Split Flow: 40 mL/min.<br />

Part No.<br />

N9316359<br />

Capillary Column Applications Gas Chromatography<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

119


Capillary Columns<br />

Phase Cross-Reference<br />

Gas Chromatography Capillary Columns<br />

Phase Phase Description Equivalent Phase<br />

Elite-1, Elite-1ht 100% Dimethyl Packed: OV-1, OV-101, SP-2100, DC-200, UC-W982, S 96, CP-Sil 5, SE-30<br />

Capillary: DB-1, DB-1ht, HP-1, HP-101, Ultra-1, SPB-1, CP-Sil 5CB, Cl-Sil5CBMS,<br />

RSL-150, RSL-160, Rtx-1, BP-1, CB-1, OV-1, 007-1(MS), SP-2100, SE-30<br />

Elite-5, Elite-5ht, 5% Diphenyl – 95% Dimethyl Packed: OV-3, OV-73, Dexsil 300, Fluorolube, CP-Sil 8<br />

Elite-5ms<br />

Capillary: DB-5, DB-5ms, DB-5ht, HP-5, Ultra-2, SPB-5, CP-Sil 8CB, RSL-200, Rtx-5,<br />

BP-5, CB-5, OV-5, 007-2(MPS-5), SE-52, SE-54, XTI-5, Rtx-5 ms, PTE-5, HP-5MS<br />

Elite-5Amine 5% Diphenyl – 95% Dimethyl Polysiloxane Rtx-5Amine; PTA-5<br />

Elite-17, Elite-17ht, 50% Phenyl – 50% Methyl Packed: OV-17, OV-11, OV-22, SP-2250, DC-710<br />

Elite-17ms<br />

Capillary: DB-17, DB-17ht, HP-17, RSL-300, Rtx-50, 007-17(MPS-50),<br />

SP-2250, HP-50+<br />

Elite-35, Elite-35ms 35% Phenyl – 65% Methyl Capillary: DB-35, DB-35ms, Rtx-35, SPB-35, AT-35, Sup-Herb<br />

Elite-200 Trifluoropropylmethyl Polysiloxane DB-210; AT-210; VF-200MS; 007-210; Rtx-200<br />

Elite-225 50% Cyanopropylmethyl – Packed: OV-225, Silar 5 CP<br />

50% Phenylmethyl Capillary: DB-225, HP-225, SP-2330, CP-Sil 43CB, RSL-500, Rtx-225,<br />

BP-225, CB-225, OV-225, 007-225<br />

Elite-608<br />

Specialty phase for semivolatile<br />

pesticides (U.S. EPA 608)<br />

Capillary: SPB-608, NON-PAKD Pesticide, DB-608, 007-608, HP-608<br />

Elite-624, Specialty phase for volatiles Capillary: DB-624, DB-VRX, VOCOL, NONPAKD AT-624, Rtx-Volatiles,<br />

Elite-Volatiles (U.S. EPA 624 and 502.2) Rtx-502.2, 007-624, 007-502, HP-624, CP-624, Rtx-624<br />

Elite-1301 6% Cyanopropylphenyl – 94% Methyl Capillary: DB-1301, Rtx-1301, CP-624<br />

Elite-1701 14% Cyanopropylphenyl – 86% Dimethyl Packed: OV-1701<br />

Capillary: DB-1701, SPB-7, CP-Sil 19CB, Rtx-1701, BP-10, CB-1701,<br />

OV-1701, 007-1701<br />

Elite-Alumina PLOT phase for analysis Packed: Alumina<br />

of light hydrocarbons<br />

Capillary: GS-Alumina, Al 2 O 3 /KC1, Al 2 O 3 /Na 2 SO 4 , RT-Alumina<br />

Elite-Betacydex Betacyclodextrin for chiral separations Capillary: Cyclodex-B, LIPODEX C, Chirasil-D/L-Val, Rt-bDEXm<br />

Elite-CLPesticides Specialty phase for chlorinated pesticides Rtx-CLPesticides<br />

Elite-CLPesticides2 Specialty phase for chlorinated pesticides Rtx-CLPesticides<br />

Elite-FFAP Polyethylene Glycol – Acid Modified Packed: OV-351, FFAP, Carbowax 20M-Terephthalic acid<br />

Capillary: DB-WAX, HP-FFAP, Nukol, SUPEROX FA, STABILWAX-DA, 007-FFAP,<br />

OV-351, DB-FFAP<br />

Elite-Molesieve PLOT phase for analysis Packed: Molesieve 5A<br />

of permanent gases<br />

Capillary: GS-Molesieve, Molesieve 5A, #PLT-5A, Rt-Molesieve 5A<br />

Elite-PONA<br />

Dimethylpolysiloxane processed for<br />

detailed analysis of petroleum naphtha Capillary: DB-Petro100, Petrocol DH, HP-PONA, SPB-1, 007-1, Rtx-1 PONA<br />

Elite-Q PLOT phase for analysis Packed: Chomosorb 101, HayeSep Q, Porapak Q<br />

of light gases and hydrocarbons<br />

Capillary: GS-Q, PoraPLOT Q, Rt-QPLOT<br />

Elite-VMS Specialty phase for U.S. EPA Volatile Organics Rtx-VMS<br />

Elite-WAX Polyethylene Glycol Packed: Carbowax 20M, SUPEROX, SUPELCOWAX 10, PEG<br />

Capillary: DB-FFAP, HP-20M, SUPELCOWAX 10, CP-WAX 52CB, SUPEROX II,<br />

CB-WAX, STABILWAX, BP-20, Elite-CW, 007-CW, Carbowax, HP-Innowax<br />

120


Capillary Columns<br />

PerkinElmer Elite Series Capillary Columns<br />

Elite-1 Dimethylpolysiloxane<br />

100% Dimethyl Polysiloxane phase:<br />

The 100% Dimethyl Polysiloxane is a highly versatile phase<br />

that is extremely rugged, exhibiting long column lifetime,<br />

low bleed, and high maximum operating temperatures.<br />

Primary applications:<br />

Elite columns are ideal for the analysis of non-polar<br />

petrochemical samples, such as detailed hydrocarbon<br />

analysis, hydrocarbon gases, petroleum oxygenates,<br />

petroleum aromatics, fuels, waxes, oils, sulfur compounds,<br />

mercaptans, and carbon disulfide. It also is an excellent<br />

phase for solvents, chemicals, flavors, fragrances, essential<br />

oils, air toxins, chlorofluorocarbons, arson analysis, and<br />

high-temperature applications.<br />

Inner Film Temperature<br />

Diameter Length Thickness Limits<br />

(mm i.d.) (m) (μm) (°C) Part No. Each (€)<br />

0.05 10 0.05 -60 to 330/350 N9316056 650<br />

0.05 10 0.20 -60 to 330/350 N9316057 650<br />

0.10 10 0.10 -60 to 330/350 N9316058 574<br />

0.10 20 0.40 -60 to 320/340 N9316061 625<br />

0.18 10 0.18 -60 to 330/350 N9316001 332<br />

0.18 10 0.40 -60 to 320/340 N9316002 332<br />

0.18 20 0.18 -60 to 330/350 N9316003 523<br />

0.18 20 0.40 -60 to 320/340 N9316004 445<br />

0.18 40 0.40 -60 to 320/340 N9316005 944<br />

0.20 12 0.33 -60 to 330/350 N9316062 325<br />

0.20 25 0.33 -60 to 330/350 N9316063 445<br />

0.20 50 0.33 -60 to 330/350 N9316064 738<br />

0.25 15 0.10 -60 to 330/350 N9316006 357<br />

0.25 15 0.25 -60 to 330/350 N9316007 318<br />

0.25 15 1.00 -60 to 320/340 N9316008 318<br />

0.25 30 0.10 -60 to 330/350 N9316009 606<br />

0.25 30 0.25 -60 to 330/350 N9316010 547<br />

0.25 30 1.00 -60 to 330/350 N9316011 547<br />

0.25 60 0.10 -60 to 330/350 N9316012 1046<br />

0.25 60 0.25 -60 to 330/350 N9316013 930<br />

0.25 60 1.00 -60 to 320/340 N9316014 891<br />

0.25 100 0.50 -60 to 300/320 N9316015 1057<br />

0.32 15 0.10 -60 to 330/350 N9316016 381<br />

0.32 15 0.25 -60 to 330/350 N9316017 356<br />

0.32 15 1.00 -60 to 320/340 N9316018 389<br />

0.32 15 3.00 -60 to 280/300 N9316019 389<br />

0.32 15 5.00 -60 to 260/280 N9316020 356<br />

0.32 25 0.52 -60 to 330/350 N9316021 483<br />

0.32 30 0.10 -60 to 330/350 N9316022 573<br />

0.32 30 0.25 -60 to 330/350 N9316023 547<br />

0.32 30 1.00 -60 to 320/340 N9316024 573<br />

0.32 30 3.00 -60 to 280/300 N9316025 573<br />

0.32 30 5.00 -60 to 260/280 N9316026 445<br />

0.32 60 0.10 -60 to 330/350 N9316027 1141<br />

0.32 60 0.25 -60 to 330/350 N9316028 1122<br />

0.32 60 1.00 -60 to 320/340 N9316029 993<br />

0.32 60 3.00 -60 to 280/300 N9316030 1122<br />

0.32 60 5.00 -60 to 260/280 N9316031 993<br />

0.45* 5 4.25 -60 to 260/280 N9316032 147<br />

0.45* 15 0.13 -60 to 340/360 N9316033 402<br />

0.45* 15 0.42 -60 to 310/330 N9316037 402<br />

0.45* 15 1.27 -60 to 310/330 N9316034 402<br />

0.45* 15 2.55 -60 to 270/290 N9316035 402<br />

0.45* 15 4.25 -60 to 260/280 N9316036 402<br />

0.45* 30 0.42 -60 to 310/330 N9316041 721<br />

0.45* 30 1.27 -60 to 310/330 N9316038 721<br />

0.45* 30 2.55 -60 to 270/290 N9316039 721<br />

Inner Film Temperature<br />

Diameter Length Thickness Limits<br />

(mm i.d.) (m) (μm) (°C) Part No. Each (€)<br />

0.45* 30 4.25 -60 to 260/280 N9316040 721<br />

0.45* 60 1.27 -60 to 310/330 N9316042 1148<br />

0.45* 105 2.55 -60 to 270/290 N9316043 1836<br />

0.53 5 5.00 -60 to 270/290 N9316044 147<br />

0.53 15 0.15 -60 to 320/340 N9316045 356<br />

0.53 15 0.50 -60 to 310/330 N9316049 356<br />

0.53 15 1.50 -60 to 310/330 N9316046 356<br />

0.53 15 3.00 -60 to 270/290 N9316047 292<br />

0.53 15 5.00 -60 to 270/290 N9316048 402<br />

0.53 30 0.50 -60 to 310/320 N9316053 636<br />

0.53 30 1.50 -60 to 310/320 N9316050 636<br />

0.53 30 3.00 -60 to 270/290 N9316051 636<br />

0.53 30 5.00 -60 to 270/290 N9316052 636<br />

0.53 60 1.50 -60 to 310/330 N9316054 993<br />

* Ferrule size same as 0.53.<br />

Elite-1ht (High-Temp)<br />

Dimethylpolysiloxane<br />

Inner Film Temperature<br />

Diameter Length Thickness Limits<br />

(mm i.d.) (m) (μm) (°C) Part No. Each (€)<br />

0.25 15 0.10 -60 to 380 N9316268 383<br />

0.25 30 0.10 -60 to 380 N9316269 573<br />

0.32 15 0.10 -60 to 380 N9316270 414<br />

0.32 30 0.10 -60 to 380 N9316271 636<br />

Capillary Columns Gas Chromatography<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

121


Capillary Columns<br />

PerkinElmer Elite Series Capillary Columns<br />

Gas Chromatography Capillary Columns<br />

Elite-5 (5% – Diphenyl) –<br />

Dimethylpolysiloxane<br />

Inner Film Temperature<br />

Diameter Length Thickness Limits<br />

(mm i.d.) (m) (μm) (°C) Part No. Each (€)<br />

0.05 10 0.05 -60 to 325/350 N9316104 650<br />

0.05 10 0.20 -60 to 325/350 N9316105 650<br />

0.10 20 0.10 -60 to 330/350 N9316108 547<br />

0.10 20 0.40 -60 to 320/340 N9316109 625<br />

0.18 20 0.18 -60 to 325/340 N9316068 523<br />

0.18 10 0.18 -60 to 325/340 N9316066 332<br />

0.18 10 0.40 -60 to 315/330 N9316067 292<br />

0.18 20 0.40 -60 to 315/330 N9316069 445<br />

0.18 40 0.40 -60 to 315/330 N9316071 829<br />

0.20 12 0.33 -60 to 320/350 N9316110 325<br />

0.20 25 0.33 -60 to 330/350 N9316111 445<br />

0.20 50 0.33 -60 to 330/350 N9316112 848<br />

0.25 15 0.10 -60 to 330/350 N9316072 357<br />

0.25 15 0.25 -60 to 330/350 N9316073 318<br />

0.25 15 1.00 -60 to 320/340 N9316074 292<br />

0.25 30 0.10 -60 to 330/350 N9316075 573<br />

0.25 30 0.25 -60 to 330/350 N9316076 509<br />

0.25 30 1.00 -60 to 320/340 N9316077 509<br />

0.25 60 0.10 -60 to 330/350 N9316078 1046<br />

0.25 60 0.25 -60 to 330/340 N9316079 891<br />

0.25 60 1.00 -60 to 320/350 N9316080 891<br />

0.32 15 0.10 -60 to 330/350 N9316081 389<br />

0.32 15 0.25 -60 to 330/350 N9316082 356<br />

0.32 15 1.00 -60 to 330/350 N9316083 389<br />

0.32 25 0.52 -60 to 330/350 N9316084 509<br />

0.32 30 0.10 -60 to 330/350 N9316085 547<br />

0.32 30 0.25 -60 to 330/350 N9316086 573<br />

0.32 30 1.00 -60 to 330/350 N9316087 547<br />

0.32 50 1.00 -60 to 330/350 N9316088 828<br />

0.32 60 0.10 -60 to 330/350 N9316089 1141<br />

0.32 60 0.25 -60 to 330/350 N9316090 993<br />

0.32 60 1.00 -60 to 330/350 N9316091 993<br />

0.45* 15 0.42 -60 to 310/330 N9316093 402<br />

0.45* 15 1.27 -60 to 310/330 N9316092 402<br />

0.45* 30 0.42 -60 to 310/330 N9316096 721<br />

0.45* 30 1.27 -60 to 310/330 N9316094 721<br />

0.45* 30 4.25 -60 to 270/290 N9316095 721<br />

0.45* 60 1.27 -60 to 310/330 N9316097 1148<br />

0.53 15 0.50 -60 to 310/330 N9316099 363<br />

0.53 15 1.50 -60 to 310/330 N9316098 356<br />

0.53 30 0.50 -60 to 310/330 N9316102 636<br />

0.53 30 1.50 -60 to 310/330 N9316100 611<br />

0.53 30 5.00 -60 to 270/290 N9316101 636<br />

0.53 60 1.50 -60 to 310/330 N9316103 993<br />

* Ferrule size same as 0.53.<br />

Elite-5Amine<br />

Inner Film Temperature<br />

Diameter Length Thickness Limits<br />

(mm i.d.) (m) (μm) (°C) Part No. Each (€)<br />

0.25 30 0.50 -60 to 300/315 N9316673 675<br />

0.25 15 1.00 -60 to 300/315 N9316674 445<br />

0.25 30 1.00 -60 to 300/315 N9316675 675<br />

0.32 15 1.00 -60 to 300/315 N9316676 458<br />

0.32 30 1.00 -60 to 300/315 N9316677 713<br />

0.32 15 1.50 -60 to 290/305 N9316678 458<br />

0.32 30 1.50 -60 to 290/305 N9316679 713<br />

0.53 30 1.00 -60 to 290/305 N9316680 789<br />

0.53 15 3.00 -60 to 280/305 N9316681 483<br />

0.53 30 3.00 -60 to 280/305 N9316682 789<br />

0.25 15 0.50 -60 to 300/315 N9316684 445<br />

Elite-5ht (High-Temp)<br />

(5% – Diphenyl) –<br />

Dimethylpolysiloxane<br />

Inner Film Temperature<br />

Diameter Length Thickness Limits<br />

(mm i.d.) (m) (μm) (°C) Part No. Each (€)<br />

0.25 15 0.10 -60 to 400 N9316272 383<br />

0.25 30 0.10 -60 to 400 N9316273 611<br />

0.32 15 0.10 -60 to 400 N9316274 356<br />

0.32 30 0.10 -60 to 400 N9316275 611<br />

Elite-5ms (5% – Diphenyl) –<br />

Dimethylpolysiloxane<br />

Inner Film Temperature<br />

Diameter Length Thickness Limits<br />

(mm i.d.) (m) (μm) (°C) Part No. Each (€)<br />

0.18 20 0.18 -60 to 325/340 N9316276 547<br />

0.18 40 0.18 -60 to 325/340 N9316277 930<br />

0.20 12 0.33 -60 to 330/350 N9316301 344<br />

0.20 25 0.33 -60 to 330/350 N9316302 483<br />

0.20 50 0.33 -60 to 330/350 N9316303 828<br />

0.25 15 0.10 -60 to 330/350 N9316278 402<br />

0.25 15 0.25 -60 to 330/350 N9316279 402<br />

0.25 15 1.00 -60 to 325/350 N9316280 402<br />

0.25 30 0.10 -60 to 330/350 N9316281 638<br />

0.25 30 0.25 -60 to 330/350 N9316282 611<br />

0.25 30 1.00 -60 to 325/350 N9316283 611<br />

0.25 30 0.50 -60 to 330/350 N9316284 611<br />

0.25 60 0.10 -60 to 330/350 N9316285 1084<br />

0.25 60 0.25 -60 to 330/350 N9316286 1019<br />

0.25 60 1.00 -60 to 325/350 N9316287 993<br />

0.32 15 0.10 -60 to 330/350 N9316288 421<br />

0.32 15 0.25 -60 to 330/350 N9316289 421<br />

0.32 15 1.00 -60 to 325/350 N9316290 421<br />

0.32 25 0.52 -60 to 330/350 N9316291 561<br />

0.32 30 0.10 -60 to 330/350 N9316292 695<br />

0.32 30 0.25 -60 to 330/350 N9316293 636<br />

0.32 30 1.00 -60 to 325/350 N9316294 636<br />

0.32 30 0.50 -60 to 330/350 N9316295 636<br />

0.32 60 0.10 -60 to 330/350 N9316296 1186<br />

0.32 60 0.25 -60 to 330/350 N9316297 1083<br />

0.32 60 1.00 -60 to 330/350 N9316298 1186<br />

0.53 15 1.50 -60 to 310/330 N9316299 434<br />

0.53 30 1.50 -60 to 310/330 N9316300 700<br />

122


Capillary Columns<br />

PerkinElmer Elite Series Capillary Columns<br />

Elite-17 (50% – Phenyl) –<br />

Methylpolysiloxane<br />

Inner Film Temperature<br />

Diameter Length Thickness Limits<br />

(mm i.d.) (m) (μm) (°C) Part No. Each (€)<br />

0.05 10 0.05 40 to 280/300 N9316138 650<br />

0.05 10 0.10 40 to 280/300 N9316139 650<br />

0.10 10 0.10 40 to 280/300 N9316140 574<br />

0.10 10 0.02 40 to 280/300 N9316141 574<br />

0.10 20 0.10 40 to 280/300 N9316142 625<br />

0.10 20 0.20 40 to 280/300 N9316143 625<br />

0.18 10 0.18 40 to 310/300 N9316113 332<br />

0.18 10 0.30 40 to 300/320 N9316114 332<br />

0.18 20 0.18 40 to 310/330 N9316115 523<br />

0.18 20 0.30 40 to 300/320 N9316116 523<br />

0.25 15 0.15 40 to 300/320 N9316117 357<br />

0.25 15 0.25 40 to 300/320 N9316118 357<br />

0.25 15 0.50 40 to 290/310 N9316119 357<br />

0.25 30 0.15 40 to 300/320 N9316120 606<br />

0.25 30 0.25 40 to 300/320 N9316121 547<br />

0.25 30 0.50 40 to 290/310 N9316122 547<br />

0.25 60 0.25 40 to 290/310 N9316123 891<br />

0.32 15 0.15 40 to 300/320 N9316124 389<br />

0.32 15 0.25 40 to 300/320 N9316125 389<br />

0.32 15 0.50 40 to 290/310 N9316126 389<br />

0.32 30 0.15 40 to 300/320 N9316127 644<br />

0.32 30 0.25 40 to 300/320 N9316128 644<br />

0.32 30 0.50 40 to 290/310 N9316129 547<br />

0.45* 5 1.70 40 to 260/280 N9316130 147<br />

0.45* 15 0.85 40 to 270/290 N9316131 402<br />

0.45* 30 0.85 40 to 270/290 N9316132 721<br />

0.45* 60 0.85 40 to 260/280 N9316133 1148<br />

0.53 5 2.00 40 to 250/270 N9316134 147<br />

0.53 15 1.00 40 to 260/280 N9316135 356<br />

0.53 30 1.00 40 to 260/280 N9316136 636<br />

0.53 60 1.00 40 to 260/280 N9316137 1148<br />

* Ferrule size same as 0.53<br />

Elite-17ht (High-Temp)<br />

(50% – Phenyl) –<br />

Methylpolysiloxane<br />

Inner Film Temperature<br />

Diameter Length Thickness Limits<br />

(mm i.d.) (m) (μm) (°C) Part No. Each<br />

0.25 15 0.15 40 to 300/320 N9316263 383<br />

0.25 30 0.15 40 to 300/320 N9316264 625<br />

0.32 15 0.15 40 to 300/320 N9316265 414<br />

0.32 30 0.15 40 to 300/320 N9316266 676<br />

0.32 60 0.15 40 to 300/320 N9316267 1173<br />

(€)<br />

Elite-17ms (Low Bleed)<br />

(50% – Phenyl) –<br />

Methylpolysiloxane<br />

Inner Film Temperature<br />

Diameter Length Thickness Limits<br />

(mm i.d.) (m) (μm) (°C) Part No. Each (€)<br />

0.18 20 0.18 40 to 320/340 N9316534 599<br />

0.25 15 0.15 40 to 300/320 N9316535 434<br />

0.25 15 0.25 40 to 300/320 N9316536 434<br />

0.25 30 0.15 40 to 300/320 N9316537 611<br />

0.25 30 0.25 40 to 300/320 N9316538 701<br />

0.25 60 0.25 40 to 300/320 N9316539 1205<br />

0.32 15 0.15 40 to 300/320 N9316540 471<br />

0.32 15 0.25 40 to 300/320 N9316541 472<br />

0.32 30 0.15 40 to 300/320 N9316542 759<br />

Elite-35 (35% – Diphenyl) –<br />

Dimethylpolysiloxane<br />

Inner Film Temperature<br />

Diameter Length Thickness Limits<br />

(mm i.d.) (m) (μm) (°C) Part No. Each (€)<br />

0.25 30 0.15 40 to 300/320 N9316144 606<br />

0.25 30 0.25 40 to 300/320 N9316145 606<br />

0.32 30 0.25 40 to 300/320 N9316146 547<br />

0.32 30 0.50 40 to 290/310 N9316147 644<br />

0.45* 15 0.85 40 to 280/300 N9316148 402<br />

0.45* 30 0.42 40 to 290/310 N9316150 721<br />

0.45* 30 0.85 40 to 280/300 N9316149 721<br />

0.53 15 1.00 40 to 260/280 N9316151 402<br />

0.53 30 0.50 40 to 260/280 N9316153 611<br />

0.53 30 1.00 40 to 260/280 N9316152 721<br />

Elite-35ms (35% – Phenyl) –<br />

Methylpolysiloxane<br />

Inner Film Temperature<br />

Diameter Length Thickness Limits<br />

(mm i.d.) (m) (μm) (°C) Part No. Each (€)<br />

0.20 25 0.33 50 to 320/340 N9316446 536<br />

0.25 15 0.25 50 to 320/340 N9316436 402<br />

0.25 30 0.15 50 to 320/340 N9316437 644<br />

0.25 30 0.25 50 to 320/340 N9316438 644<br />

0.25 60 0.25 50 to 320/340 N9316439 1019<br />

0.32 15 0.25 50 to 320/340 N9316440 421<br />

0.32 30 0.25 50 to 320/340 N9316441 636<br />

0.32 60 0.25 50 to 320/340 N9316442 1186<br />

0.53 15 1.00 50 to 290/310 N9316443 434<br />

0.53 30 1.00 50 to 290/310 N9316444 759<br />

0.53 30 0.50 50 to 300/320 N9316445 759<br />

Capillary Columns Gas Chromatography<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

123


Capillary Columns<br />

PerkinElmer Elite Series Capillary Columns<br />

Gas Chromatography Capillary Columns<br />

Elite-200 Trifluoropropylmethyl<br />

Polysiloxane<br />

Inner Film Temperature<br />

Diameter Length Thickness Limits<br />

(mm i.d.) (m) (μm) (°C) Part No. Each (€)<br />

0.18 10 0.20 -20 to 310/330 N9316610 343<br />

0.18 20 0.20 -20 to 310/330 N9316611 522<br />

0.18 40 0.20 -20 to 310/330 N9316612 917<br />

0.18 10 0.40 -20 to 310/330 N9316613 343<br />

0.18 20 0.40 -20 to 310/330 N9316614 522<br />

0.18 40 0.40 -20 to 310/330 N9316615 917<br />

0.25 15 0.10 -20 to 320/340 N9316616 381<br />

0.25 30 0.10 -20 to 320/340 N9316617 611<br />

0.25 15 0.25 -20 to 320/340 N9316618 369<br />

0.25 30 0.25 -20 to 320/340 N9316619 598<br />

0.25 15 0.50 -20 to 310/330 N9316620 369<br />

0.25 30 0.50 -20 to 310/330 N9316621 598<br />

0.25 15 1.00 -20 to 290/310 N9316622 369<br />

0.25 30 1.00 -20 to 290/310 N9316623 598<br />

0.25 60 1.00 -20 to 290/310 N9316624 993<br />

0.32 15 0.25 -20 to 320/340 N9316625 420<br />

0.32 30 0.25 -20 to 320/340 N9316626 636<br />

0.32 15 0.50 -20 to 310/330 N9316627 420<br />

0.32 30 0.50 -20 to 310/330 N9316628 636<br />

0.32 15 1.00 -20 to 290/310 N9316629 420<br />

0.32 30 1.00 -20 to 290/310 N9316630 636<br />

0.32 60 1.00 -20 to 290/310 N9316631 1095<br />

0.32 15 1.50 -20 to 280/300 N9316632 420<br />

0.32 30 1.50 -20 to 280/300 N9316633 636<br />

0.32 60 1.50 -20 to 280/300 N9316634 1095<br />

0.53 15 0.25 -20 to 310/330 N9316635 445<br />

0.53 30 0.25 -20 to 310/330 N9316636 726<br />

0.53 60 0.25 -20 to 310/330 N9316637 1185<br />

0.53 15 0.50 -20 to 300/320 N9316638 445<br />

0.53 30 0.50 -20 to 300/320 N9316639 726<br />

0.53 60 0.50 -20 to 300/320 N9316640 1185<br />

0.53 15 1.00 -20 to 290/310 N9316641 445<br />

0.53 30 1.00 -20 to 290/310 N9316642 726<br />

0.53 60 1.00 -20 to 290/310 N9316643 1185<br />

0.53 15 1.50 -20 to 280/300 N9316644 445<br />

0.53 30 1.50 -20 to 280/300 N9316645 726<br />

0.53 60 1.50 -20 to 280/300 N9316646 1185<br />

0.53 15 3.00 -20 to 260/280 N9316647 445<br />

0.53 30 3.00 -20 to 260/280 N9316648 726<br />

0.53 60 3.00 -20 to 260/280 N9316649 1185<br />

Elite-225 (50% –<br />

Cyanopropylmethyl) –<br />

Phenylmethylpolysiloxane<br />

Inner Film Temperature<br />

Diameter Length Thickness Limits<br />

(mm i.d.) (m) (μm) (°C) Part No. Each<br />

0.05 10 0.05 45 to 220/240 N9316186 636<br />

0.10 20 0.10 45 to 220/240 N9316187 625<br />

0.18 10 0.20 45 to 220/240 N9316172 332<br />

0.18 20 0.20 45 to 220/240 N9316173 523<br />

0.25 15 0.15 45 to 220/240 N9316174 363<br />

0.25 15 0.25 45 to 220/240 N9316175 318<br />

0.25 30 0.15 45 to 220/240 N9316176 619<br />

0.25 30 0.25 45 to 220/240 N9316177 547<br />

0.32 15 0.15 45 to 220/240 N9316178 402<br />

0.32 15 0.25 45 to 220/240 N9316179 402<br />

0.32 30 0.15 45 to 220/240 N9316180 670<br />

0.32 30 0.25 45 to 220/240 N9316181 573<br />

0.45* 15 0.85 40 to 200/220 N9316182 395<br />

0.45* 30 0.85 40 to 200/220 N9316183 740<br />

0.53 15 1.00 40 to 200/220 N9316184 395<br />

0.53 30 1.00 40 to 200/220 N9316185 636<br />

Elite-502.2 Specialty Phase for<br />

Analysis of Volatiles (U.S. EPA 502.2)<br />

Inner Film Temperature<br />

Diameter Length Thickness Limits<br />

(mm i.d.) (m) (μm) (°C) Part No. Each<br />

0.25 60 1.40 0 to 250/270 N9316498 1065<br />

0.45* 105 2.55 0 to 250/270 N9316189 1836<br />

0.45* 75 2.55 0 to 250/270 N9316188 1338<br />

0.53 105 3.00 0 to 250/270 N9316190 1210<br />

Elite-608 Specialty Phase for<br />

Semivolatile Pesticides (U.S. EPA 608)<br />

Inner Film Temperature<br />

Diameter Length Thickness Limits<br />

(mm i.d.) (m) (μm) (°C) Part No. Each (€)<br />

0.32 30 0.50 40 to 290/310 N9316191 547<br />

0.45* 15 0.42 40 to 270/290 N9316194 402<br />

0.45* 15 0.70 40 to 260/280 N9316192 402<br />

0.45* 30 0.42 40 to 270/290 N9316195 721<br />

0.45* 30 0.70 40 to 260/280 N9316193 721<br />

0.53 15 0.50 40 to 270/290 N9316198 402<br />

0.53 15 0.83 40 to 260/280 N9316196 402<br />

0.53 30 0.50 40 to 270/290 N9316199 611<br />

0.53 30 0.83 40 to 260/280 N9316197 700<br />

* Ferrule size same as 0.53<br />

(€)<br />

(€)<br />

124


Capillary Columns<br />

PerkinElmer Elite Series Capillary Columns<br />

Elite-624 Specialty Phase for<br />

Analysis of Volatiles (U.S. EPA 624)<br />

Inner Film Temperature<br />

Diameter Length Thickness Limits<br />

(mm i.d.) (m) (μm) (°C) Part No. Each (€)<br />

Inner Film Temperature<br />

Diameter Length Thickness Limits<br />

(mm i.d.) (m) (μm) (°C) Part No. Each (€)<br />

0.18 20 1.00 -20 to 240 N9316200 510<br />

0.20 25 1.12 -20 to 240 N9316209 445<br />

0.25 30 1.40 -20 to 240 N9316201 573<br />

0.25 60 1.40 -20 to 240 N9316202 1065<br />

0.32 30 1.80 -20 to 240 N9316203 611<br />

0.32 60 1.80 -20 to 240 N9316204 1057<br />

0.45* 30 2.55 -20 to 240 N9316205 829<br />

0.45* 75 2.55 -20 to 240 N9316206 1249<br />

0.53 30 3.00 -20 to 240 N9316207 700<br />

0.53 75 3.00 -20 to 240 N9316208 1249<br />

* Ferrule size same as 0.53<br />

Elite-1301<br />

(6% – Cyanopropylphenyl) –<br />

Methylpolysiloxane<br />

Inner Film Temperature<br />

Diameter Length Thickness Limits<br />

(mm i.d.) (m) (μm) (°C) Part No. Each<br />

0.18 10 0.40 -20 to 280 N9316210 332<br />

0.18 20 0.40 -20 to 280 N9316211 523<br />

0.25 15 0.25 -20 to 280 N9316212 363<br />

0.25 15 1.00 -20 to 260/280 N9316213 363<br />

0.25 30 0.25 -20 to 280 N9316214 619<br />

0.25 30 1.00 -20 to 260/280 N9316215 619<br />

0.25 60 0.25 -20 to 280 N9316216 1065<br />

0.25 60 1.00 -20 to 260/280 N9316217 1065<br />

0.32 15 0.25 -20 to 280 N9316218 402<br />

0.32 30 0.25 -20 to 280 N9316220 670<br />

0.32 60 0.25 -20 to 280 N9316222 1173<br />

0.32 15 1.00 -20 to 260/280 N9316219 402<br />

0.32 30 1.00 -20 to 260/280 N9316221 670<br />

0.32 60 1.00 -20 to 260/280 N9316223 1173<br />

0.45* 15 0.85 -20 to 260/280 N9316224 395<br />

0.45* 30 0.85 -20 to 260/280 N9316225 740<br />

0.53 15 1.00 -20 to 260/280 N9316226 395<br />

0.53 30 1.00 -20 to 260/280 N9316227 636<br />

Elite-1701<br />

(14% – Cyanopropylphenyl) –<br />

Methylpolysiloxane<br />

Inner Film Temperature<br />

Diameter Length Thickness Limits<br />

(mm i.d.) (m) (μm) (°C) Part No. Each (€)<br />

0.05 10 0.05 -20 to 280 N9316257 650<br />

0.05 10 0.20 -20 to 280 N9316258 650<br />

0.10 20 0.10 -20 to 280 N9316259 547<br />

0.10 20 0.40 -20 to 270/280 N9316260 625<br />

0.18 10 0.40 -20 to 270/280 N9316228 332<br />

0.18 20 0.40 -20 to 270/280 N9316229 523<br />

0.25 15 0.15 -20 to 280 N9316230 318<br />

0.25 15 0.25 -20 to 280 N9316231 363<br />

0.25 15 1.00 -20 to 260/280 N9316232 363<br />

0.25 30 0.25 -20 to 260/280 N9316234 547<br />

0.25 30 1.00 -20 to 260/280 N9316235 547<br />

0.25 60 0.15 -20 to 280 N9316236 1065<br />

0.25 60 0.25 -20 to 280 N9316237 1057<br />

(€)<br />

0.25 60 1.00 -20 to 260/280 N9316238 930<br />

0.32 15 0.15 -20 to 280 N9316239 402<br />

0.32 15 0.25 -20 to 280 N9316240 402<br />

0.32 15 1.00 -20 to 260/280 N9316241 402<br />

0.32 30 0.15 -20 to 280 N9316242 573<br />

0.32 30 0.25 -20 to 280 N9316243 573<br />

0.32 30 1.00 -20 to 260/280 N9316244 573<br />

0.32 50 1.00 -20 to 260/280 N9316245 828<br />

0.32 60 0.15 -20 to 280 N9316246 1173<br />

0.32 60 0.25 -20 to 280 N9316247 828<br />

0.32 60 1.00 -20 to 260/280 N9316248 1019<br />

0.45* 15 0.42 -20 to 260/270 N9316250 395<br />

0.45* 15 0.85 -20 to 250/270 N9316249 395<br />

0.45* 30 0.42 -20 to 260/270 N9316252 740<br />

0.45* 30 0.85 -20 to 250/270 N9316251 740<br />

0.53 15 1.00 -20 to 250/270 N9316253 356<br />

0.53 15 0.50 -20 to 260/270 N9316254 395<br />

0.53 30 0.50 -20 to 260/270 N9316256 740<br />

0.53 30 1.00 -20 to 250/270 N9316255 740<br />

Elite-BAC Blood Alcohol Analysis<br />

Columns for GC and High-Speed<br />

Headspace Gas Chromatography<br />

Now using the PerkinElmer Blood Alcohol columns,<br />

standard separations and automated separations of less than<br />

1.5 minutes can be accomplished. Sample concentrations<br />

range from 0.01 to 0.05% with quantitative precision<br />

of


Capillary Columns<br />

PerkinElmer Elite Series Capillary Columns<br />

Elite-CLPesticides<br />

Elite-CLPesticides is specially designed to overcome the<br />

coelutions and analyte breakdown typically encountered in<br />

chlorinated pesticide analyses for U.S. EPA methods 8081,<br />

608, and CLP. Column bleed measured by ECD is extremely<br />

low at temperatures greater than 300 °C, which is critical for<br />

baking out the column to remove high-boiling compounds<br />

commonly found in pesticide/PCB extracts.<br />

Gas Chromatography Capillary Columns<br />

Primary Applications<br />

Chlorinated Pesticides and Herbicides. U.S. EPA Methods<br />

504, 608, 619, 8081, 8151, and CLP.<br />

Features and Benefits:<br />

■ Thermally stable to 340 °C<br />

■ Low column bleed – ideal for ECD or GC/MS analysis<br />

■ Exceeds performance criteria for U.S. EPA Methods<br />

8081, 608, CLP<br />

■ Baseline separation in less than 15 minutes<br />

Inner<br />

Film<br />

Diameter Length Thickness<br />

(mm i.d.) (m) (μm) Part No. Each (€)<br />

0.25 15 0.25 N9316661 432<br />

0.25 30 0.25 N9316662 636<br />

0.32 15 0.50 N9316663 458<br />

0.32 30 0.50 N9316664 687<br />

0.53 15 0.50 N9316665 483<br />

0.53 30 0.50 N9316666 764<br />

Elite-CLPesticides 2<br />

Inner<br />

Film<br />

Diameter Length Thickness<br />

(mm i.d.) (m) (μm) Part No. Each (€)<br />

0.25 15 0.20 N9316667 432<br />

0.25 30 0.20 N9316668 624<br />

0.32 15 0.25 N9316669 483<br />

0.32 30 0.25 N9316670 687<br />

0.53 15 0.42 N9316671 483<br />

0.53 30 0.42 N9316672 764<br />

126


Capillary Columns<br />

PerkinElmer Elite Series Capillary Columns<br />

Elite-FFAP Nitroterephthalic<br />

Acid Modified Polyethylene<br />

Glycol (Bonded)<br />

Inner Film Temperature<br />

Diameter Length Thickness Limits<br />

(mm i.d.) (m) (μm) (°C) Part No. Each (€)<br />

Elite-SimDist<br />

Dimethylpolysiloxane Processed<br />

for Simulated Distillation<br />

Inner Film Temperature<br />

Diameter Length Thickness Limits<br />

(mm i.d.) (m) (μm) (°C) Part No. Each (€)<br />

0.25 15 0.25 40 to 250 N9316351 318<br />

0.25 30 0.25 40 to 250 N9316352 547<br />

0.32 15 0.25 40 to 250 N9316353 356<br />

0.32 30 0.25 40 to 250 N9316354 547<br />

0.45* 15 0.85 40 to 240/250 N9316355 356<br />

0.45* 30 0.85 40 to 240/250 N9316356 721<br />

0.53 15 1.00 40 to 240/250 N9316357 402<br />

0.53 30 1.00 40 to 240/250 N9316358 611<br />

Elite-HT SimDist<br />

for High-Temperature<br />

Simulated Distillation<br />

Inner Film Temperature<br />

Diameter Length Thickness Limits<br />

(mm i.d.) (m) (μm) (°C) Part No. Each (€)<br />

0.53 6 0.15 -60 to 400 N9316572 318<br />

Elite-MTBE Low Polarity<br />

Stationary Phase<br />

Inner Film Temperature<br />

Diameter Length Thickness Limits<br />

(mm i.d.) (m) (μm) (°C) Part No. Each (€)<br />

0.45 30 2.55 10 to 250 N9316520 797<br />

0.53 30 3.00 10 to 250 N9316521 797<br />

Elite-PONA Dimethylpolysiloxane<br />

Processed for Detailed Analysis<br />

of Petroleum Naphtha<br />

Inner Film Temperature<br />

Diameter Length Thickness Limits<br />

(mm i.d.) (m) (μm) (°C) Part No. Each (€)<br />

0.25 100 0.50 -60 to 300/320 N9316015 1057<br />

0.20 50 0.50 -60 to 300/320 N9316065 764<br />

Elite-RX for Analysis<br />

of Drugs of Abuse<br />

Inner Film Temperature<br />

Diameter Length Thickness Limits<br />

(mm i.d.) (m) (μm) (°C) Part No. Each (€)<br />

Phase: Elite-1-RX<br />

0.20 12 0.33 -60 to 330/350 N9316345 325<br />

0.20 25 0.33 -60 to 330/350 N9316346 445<br />

Phase: Elite-5ms-RX<br />

0.20 12 0.33 -60 to 330/350 N9316349 344<br />

0.20 25 0.33 -60 to 330/350 N9316350 483<br />

Phase: Elite-17-RX<br />

0.20 12 0.33 40 to 330/320 N9316347 325<br />

0.20 25 0.33 40 to 330/320 N9316348 445<br />

0.45* 10 2.55 -60 to 360 N9316261 281<br />

0.53 10 3.00 -60 to 360 N9316262 254<br />

Elite-TPH Specialty<br />

Phase for Analysis of<br />

Total Petroleum Hydrocarbons<br />

Inner Film Temperature<br />

Diameter Length Thickness Limits<br />

(mm i.d.) (m) (μm) (°C) Part No. Each (€)<br />

0.32 30 0.25 -10 to 320 N9316386 611<br />

0.45* 30 1.00 -10 to 290 N9316387 752<br />

Elite-VMS<br />

Inner Film Temperature<br />

Diameter Length Thickness Limits<br />

(mm i.d.) (m) (μm) (°C) Part No. Each (€)<br />

0.18 20 1.00 -40 to 240/260 N9316650 547<br />

0.18 40 1.00 -40 to 240/260 N9316651 942<br />

0.25 30 1.40 -40 to 240/260 N9316652 624<br />

0.25 60 1.40 -40 to 240/260 N9316653 1019<br />

0.32 30 1.80 -40 to 240/260 N9316654 675<br />

0.32 60 1.80 -40 to 240/260 N9316655 1121<br />

0.45 30 2.55 -40 to 240/260 N9316656 764<br />

0.45 60 2.55 -40 to 240/260 N9316657 1223<br />

0.53 30 3.00 -40 to 240/260 N9316658 764<br />

0.53 60 3.00 -40 to 240/260 N9316659 1223<br />

0.53 75 3.00 -40 to 240/260 N9316660 1338<br />

Elite-Volatiles Specialty Phase<br />

for Analysis of Volatile<br />

Organic Compounds<br />

Inner Film Temperature<br />

Diameter Length Thickness Limits<br />

(mm i.d.) (m) (μm) (°C) Part No. Each (€)<br />

0.25 30 1.40 -20 to 240 N9316388 638<br />

0.25 60 1.40 -20 to 240 N9316389 802<br />

0.32 30 1.80 -20 to 240 N9316390 714<br />

0.32 60 1.80 -20 to 240 N9316391 1083<br />

0.45* 30 2.55 -20 to 240 N9316392 764<br />

0.45* 75 2.55 -20 to 240 N9316393 1274<br />

* Ferrule size same as 0.53<br />

Capillary Columns Gas Chromatography<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

127


Capillary Columns<br />

PerkinElmer Elite Series Capillary Columns<br />

Gas Chromatography Capillary Columns<br />

Elite-MWAX<br />

Inner Film Temperature<br />

Diameter Length Thickness Limits<br />

(mm i.d.) (m) (μm) (°C) Part No. Each (€)<br />

0.53 30 1.00 20 to 240/250 N9316478 721<br />

Elite-WAX Polyethylene Glycol<br />

Inner Film Temperature<br />

Diameter Length Thickness Limits<br />

(mm i.d.) (m) (μm) (°C) Part No. Each (€)<br />

0.05 10 0.05 20 to 240/250 N9316430 650<br />

0.05 10 0.10 20 to 240/250 N9316431 650<br />

0.10 10 0.10 20 to 240/250 N9316432 574<br />

0.10 10 0.20 20 to 240/250 N9316433 574<br />

0.10 20 0.10 20 to 240/250 N9316434 625<br />

0.10 20 0.20 20 to 240/250 N9316435 625<br />

0.18 10 0.18 20 to 240/250 N9316394 332<br />

0.18 10 0.30 20 to 240/250 N9316395 332<br />

0.18 20 0.18 20 to 240/250 N9316396 523<br />

0.18 40 0.30 20 to 250/260 N9316398 944<br />

0.25 15 0.15 20 to 250 N9316399 357<br />

0.25 15 0.25 20 to 250 N9316400 357<br />

0.25 15 0.50 20 to 250 N9316401 356<br />

0.25 30 0.15 20 to 250 N9316402 606<br />

0.25 30 0.25 20 to 250 N9316403 547<br />

0.25 30 0.50 20 to 250 N9316404 547<br />

0.25 60 0.15 20 to 250 N9316405 1019<br />

0.25 60 0.25 20 to 250 N9316406 738<br />

0.25 60 0.50 20 to 250 N9316407 930<br />

0.32 15 0.15 20 to 250 N9316408 389<br />

0.32 15 0.25 20 to 250 N9316409 389<br />

0.32 15 0.50 20 to 250 N9316410 389<br />

0.32 30 0.15 20 to 250 N9316411 644<br />

0.32 30 0.25 20 to 250 N9316412 573<br />

0.32 30 0.50 20 to 250 N9316413 573<br />

0.32 60 0.25 20 to 250 N9316416 993<br />

0.32 60 0.50 20 to 250 N9316417 993<br />

0.45* 5 1.70 50 to 230 N9316418 147<br />

0.45* 15 0.42 20 to 250 N9316420 402<br />

0.45* 15 0.85 20 to 240/250 N9316419 402<br />

0.45* 30 0.42 20 to 250 N9316422 721<br />

0.45* 30 0.85 20 to 240/250 N9316421 721<br />

0.45* 60 0.85 20 to 240/250 N9316423 1148<br />

0.53 15 0.50 20 to 250 N9316426 402<br />

0.53 15 1.00 20 to 240/2540 N9316425 356<br />

0.53 30 0.50 20 to 250 N9316428 721<br />

0.53 30 1.00 20 to 240/250 N9316427 611<br />

0.53 60 1.00 20 to 240/250 N9316429 1019<br />

Elite-WAX ETR<br />

(Extended Temperature Range)<br />

Polyethylene Glycol<br />

Inner Film Temperature<br />

Diameter Length Thickness Limits<br />

(mm i.d.) (m) (μm) (°C) Part No. Each (€)<br />

0.25 15 0.25 40 to 250 N9316547 363<br />

0.25 15 0.50 40 to 250 N9316548 363<br />

0.25 30 0.25 40 to 250 N9316549 612<br />

0.25 30 0.50 40 to 250 N9316550 612<br />

0.25 60 0.25 40 to 250 N9316551 1071<br />

0.32 15 0.25 40 to 250 N9316552 396<br />

0.32 15 0.50 40 to 250 N9316553 396<br />

0.32 15 1.00 40 to 240/250 N9316554 396<br />

0.32 30 0.25 40 to 260 N9316555 676<br />

0.32 30 0.50 40 to 250 N9316556 676<br />

0.32 30 1.00 40 to 240/250 N9316557 547<br />

0.32 50 1.00 40 to 240/250 N9316558 828<br />

0.32 60 0.25 40 to 250 N9316559 1180<br />

0.32 60 0.50 40 to 250 N9316560 1180<br />

0.32 60 1.00 40 to 240/250 N9316561 993<br />

0.45 5 1.70 40 to 230/250 N9316562 147<br />

0.45 15 0.85 40 to 240 N9316563 396<br />

0.45 30 0.85 40 to 240 N9316564 746<br />

0.45 60 0.85 40 to 240 N9316565 1193<br />

0.53 5 2.00 40 to 220/230 N9316566 147<br />

0.53 15 1.00 40 to 240/250 N9316567 395<br />

0.53 15 2.00 40 to 220/230 N9316568 396<br />

0.53 30 1.00 40 to 240/250 N9316569 611<br />

0.53 30 2.00 40 to 220/230 N9316570 746<br />

0.53 60 1.00 40 to 240/250 N9316571 1192<br />

* Ferrule size same as 0.53<br />

Elite-XLB Specialty Phase<br />

for GC/MS with<br />

Exceptionally Low Bleed<br />

Inner Film Temperature<br />

Diameter Length Thickness Limits<br />

(mm i.d.) (m) (μm) (°C) Part No. Each (€)<br />

0.18 20 0.18 30 to 340/360 N9316480 548<br />

0.20 12 0.33 30 to 340/360 N9316496 351<br />

0.20 25 0.33 30 to 340/360 N9316497 536<br />

0.25 15 0.25 30 to 340/360 N9316481 402<br />

0.25 15 1.00 30 to 340/360 N9316482 402<br />

0.25 30 0.10 30 to 340/360 N9316483 636<br />

0.25 30 0.25 30 to 340/360 N9316484 611<br />

0.25 30 1.00 30 to 340/360 N9316485 636<br />

0.25 60 0.25 30 to 340/360 N9316487 1019<br />

0.32 15 0.25 30 to 340/360 N9316488 421<br />

0.32 30 0.10 30 to 340/360 N9316489 695<br />

0.32 30 0.25 30 to 340/360 N9316490 636<br />

0.32 30 0.50 30 to 340/360 N9316492 674<br />

0.32 30 1.00 30 to 340/360 N9316491 674<br />

0.32 60 0.25 30 to 340/360 N9316493 1057<br />

0.53 15 1.50 30 to 320/340 N9316494 445<br />

0.53 30 1.50 30 to 320/340 N9316495 759<br />

128


Capillary Columns<br />

PerkinElmer Elite Series Guard and PLOT Columns<br />

Elite Guard Columns<br />

Elite-Alumina/KCI* PLOT<br />

Guard Columns<br />

Maintain the integrity of your capillary column<br />

with a fused silica Guard Column.<br />

Using the Elite-Guard or Elite-Siltek Guard Column<br />

lengthens the life of the capillary column and improves the<br />

analyte focusing. The 5 m length of deactivated uncoated<br />

fused silica is connected to the inlet end of the capillary<br />

column and traps nonvolatile residues, preventing them<br />

from collecting at the head of the analytical column. This<br />

length of fused silica contains no stationary phase, adding<br />

only a minimal amount of time to the analysis.<br />

PerkinElmer offers both the Intermediate-polarity deactivated<br />

guard column and the Siltek deactivated guard column<br />

as it is important to match the polarity of the solvent<br />

and the polarity of the surface deactivation. The Elite-Guard<br />

intermediate polarity deactivated column has an operating<br />

temperature up to 325 °C. Siltek deactivation creates a<br />

highly inert surface for very active compounds such as<br />

chlorinated pesticides with a maximum temperature<br />

range up to 380 °C.<br />

Features and Benefits:<br />

■ Increases the life of the capillary column<br />

■ Maintains retention time and resolution on capillary column<br />

■ Traps nonvolatile particles<br />

■ Improves column performance<br />

■ Elite-Guard temperature range to 325 °C<br />

■ Elite-Siltek Guard temperature range to 380 °C<br />

Elite-Guard<br />

Inner<br />

Diameter Length<br />

(mm i.d.) (m) Part No. Each (€)<br />

0.10 5 N9316601 106<br />

0.18 5 N9316602 70<br />

0.25 5 N9316603 56<br />

0.32 5 N9316604 64<br />

0.45 5 N9316605 84<br />

0.53 5 N9316606 84<br />

Elite-Siltek Guard<br />

Inner<br />

Diameter Length<br />

(mm i.d.) (m) Part No. Each (€)<br />

0.25 5 N9316607 70<br />

0.32 5 N9316608 77<br />

0.53 5 N9316609 106<br />

Inner Film Temperature<br />

Diameter Length Thickness Limits<br />

(mm i.d.) (m) (μm) (°C) Part No. Each (€)<br />

0.53 50 N/A up to 200 N9316544 802<br />

* Lower Polarity than Elite Alumina.<br />

Elite-Alumina PLOT Phase for<br />

Analysis of Light Hydrocarbons<br />

Inner Film Temperature<br />

Diameter Length Thickness Limits<br />

(mm i.d.) (m) (μm) (°C) Part No. Each (€)<br />

0.53 30 N/A -60 to 200 N9316304 636<br />

0.53 50 N/A -60 to 200 N9316305 1019<br />

Note: -60 °C is the lowest temperature used on this phase in our lab.<br />

Lower temperatures may be used depending on the sample.<br />

Elite-Cyclosil B PLOT for Chiral Separations<br />

Inner Film Temperature<br />

Diameter Length Thickness Limits<br />

(mm i.d.) (m) (μm) (°C) Part No. Each (€)<br />

0.25 30 0.25 35 to 230 N9316545 650<br />

0.32 30 0.25 35 to 230 N9316546 649<br />

Elite-Molesieve PLOT Phase for<br />

Analysis of Permanent Gases<br />

Inner Film Temperature<br />

Diameter Length Thickness Limits<br />

(mm i.d.) (m) (μm) (°C) Part No. Each (€)<br />

0.53 30 N/A -60 to 300 N9316361 611<br />

Note: -60 °C is the lowest temperature used on this phase in our lab.<br />

Lower temperatures may be used depending on the sample.<br />

Elite-Q PLOT Phase for Analysis of<br />

Light Gases and Hydrocarbons<br />

Inner Film Temperature<br />

Diameter Length Thickness Limits<br />

(mm i.d.) (m) (μm) (°C) Part No. Each (€)<br />

0.32 30 N/A -60 to 250 N9316359 509<br />

0.53 30 N/A -60 to 250 N9316360 636<br />

Note: -60 °C is the lowest temperature used on this phase in our lab.<br />

Lower temperatures may be used depending on the sample.<br />

Capillary Columns Gas Chromatography<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

129


Capillary Columns<br />

PerkinElmer Packed Columns<br />

Packed Columns<br />

Packed Packed Empty Empty<br />

Length o.d. 2 mm i.d. 4 mm i.d. 2 mm i.d. 4 mm i.d.<br />

Instrument Type Material Shape (ft.) (in.) Part No. Each (€) Part No. Each (€) Part No. Each (€) Part No. Each (€)<br />

Gas Chromatography Capillary Columns<br />

AutoSystem GC Stainless 3 1/8 N9305012 126 N9304012 87<br />

Clarus Steel 6 1/8 N9305013 165 N9304013 88<br />

(not on-column) 12 1/8 N9305014 254 N9304014 101<br />

3 1/4<br />

6 1/4 N9305016 228 N9304016 88<br />

12 1/4 N9305017 356 N9304017 134<br />

Glass 3 1/4 N9305018 228 N9304018 114 N9304021 114<br />

6 1/4 N9305019 190 N9305022 292 N9304019 114 N9304022 114<br />

12 1/4 N9304020 325 N9304023 325<br />

AutoSystem GC/XL Glass 3 1/4 N9304046 126<br />

(on-column) 6 1/4 N9305047 255 N9304047 126<br />

12 1/4 N9305048 332 N9304048 268<br />

Note: Stainless steel columns are metal-fitted at both ends to contain the packing.<br />

For on-column applications, please request glass wool plugs instead of metal frits when ordering.<br />

Choose the appropriate part number from table above. Follow form at bottom of page to choose support material, % liquid<br />

phase, and mesh size. This information is required to place an order.<br />

130


Detectors<br />

Electron Capture Detectors (ECD)<br />

Add-On Kit<br />

The ECD is a versatile, nondestructive detector which<br />

responds strongly to halogen-containing compounds as<br />

well as to certain other electron-capturing substances. The<br />

ECD’s high sensitivity and selectivity make it an ideal<br />

choice for pesticide-residue analysis and for detection<br />

of halogen-derivatized compounds.<br />

The ECD has an independent temperature range of 100 -<br />

450 °C. The detector contains thermal protection that<br />

prevents heating the Ni 63 source to temperatures beyond<br />

safe operating limits. Two ECDs can be installed and<br />

operated simultaneously on the AutoSystem Series and<br />

Clarus GCs. Nitrogen or argon/methane is the required<br />

detector operating gas. The base of the detector terminates<br />

in a 1/8 in. fitting.<br />

To Amplifier<br />

ECD Add-On Kit (Manual Pneumatics)<br />

Kit includes all parts necessary to install an ECD on the<br />

AutoSystem Series or Clarus GCs. Includes detector,<br />

heater, sensor, heater block, 1/16 in. makeup gas line,<br />

makeup gas needle valve, and vent tube assembly.<br />

Requires but does not include ECD amplifier (N6120014).<br />

Installation by PerkinElmer Service is recommended.<br />

Voltage Part No. Each (€)<br />

120 V AutoSystem N6120011<br />

240 V AutoSystem N6120026 5400<br />

120 V Clarus N6520020<br />

230 V Clarus N6520021 3136<br />

ECD Amplifier<br />

Required for use with ECD detector<br />

with add-on kit.<br />

Collector Anode<br />

ECD Add-On Kit (PPC Pneumatics)<br />

Kit includes detector, heater, sensor, heater block, and<br />

programmable pneumatic control for makeup gas. Requires,<br />

but does not include, ECD amplifier (N6120014). The<br />

AutoSystem XL or Clarus GCs must be PPC ready. If not,<br />

a PPC upgrade kit (N6120146) is required. (See page 166<br />

for more information.) Installation by PerkinElmer Service<br />

is required, but not included.<br />

Voltage Part No. Each (€)<br />

120 V N6120122<br />

230 V N6120123 4037<br />

Vent Tube Assembly<br />

Flexible tube to safely vent<br />

toxic sample effluent.<br />

Column Adapters<br />

Capillary Column Adapter/Receiver<br />

Ni 63 Foil (Source)<br />

Adapter converts 1/8 in. fitting to<br />

1/16 in. for use with capillary columns.<br />

Note: Glass-lined tubing reduces background from<br />

polyimide coating in high-temperature applications.<br />

Part No.<br />

N6000968<br />

Each (€)<br />

249<br />

Makeup Gas In<br />

Column Connection<br />

Part No.<br />

Each (€)<br />

N6120014 712<br />

PID/ECD Series Operation Kit<br />

Kit for directing effluent from<br />

PID to ECD.<br />

1/4 in. Packed Column Adapter<br />

For use with 1/4 in. packed columns.<br />

1/8 to 1/4 in. adapters fit both injector<br />

and detector ends. (Pkg. 2)<br />

ECD Wipe Test Kit<br />

Part No.<br />

Part No.<br />

Each (€)<br />

N6120059 293<br />

Part No.<br />

Each (€)<br />

N6100161 47<br />

Each (€)<br />

00080100 172<br />

U.S. Federal law requires that all ECDs be wipe-tested<br />

periodically as described in the instrument operator’s<br />

manual. In the U.S., possession and use of ECD is regulated<br />

by N.R.C. and/or state regulatory agencies. Licensing by<br />

regulatory agencies is required. Outside of the U.S., check<br />

with governing bodies for licensing and regulations<br />

covering possession and use. This kit contains everything<br />

necessary to do a complete wipe test. For use on any<br />

model GC ECD.<br />

Part No. Each (€)<br />

00091667 6<br />

Detectors Gas Chromatography<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

131


Detectors<br />

Flame Ionization Detector (FID) Auto-Ignite<br />

Gas Chromatography Detectors<br />

Add-On Kits<br />

Auto-Ignite FID with PPC Add-On Kit<br />

Kit includes detector assembly with heater and sensor,<br />

heater block, igniter, programmable pneumatics, and<br />

controls for detector combustion gases. Requires but does<br />

not include amplifier (N6120162) and AutoSystem XL<br />

firmware revision 3.3 or higher. The AutoSystem XL must<br />

be PPC ready. If not, a PPC upgrade kit (N6120146)<br />

is required.<br />

Note: AutoSystem XL GCs shipped prior to January 1997 require a new<br />

detector cover. Installation by PerkinElmer Service is required, but not included.<br />

Voltage Part No. Each (€)<br />

120 V N6120167<br />

240 V N6120168 3172<br />

Auto-Ignite FID Add-On Kit (Manual Pneumatics)<br />

Kit includes detector assembly with heater and sensor,<br />

heater block, igniter, hydrogen pressure regulator, and<br />

needle valve. Requires, but does not include, amplifier<br />

(N6120162). Requires AutoSystem XL to have firmware<br />

revision 3.3 or higher.<br />

Note: AutoSystem XL GCs shipped prior to January 1997 require a new<br />

detector cover (N6103151).<br />

Voltage Part No. Each (€)<br />

120 V AutoSystem N6120165<br />

240 V AutoSystem N6120166 4158<br />

120 V Clarus N6520018<br />

230 V Clarus N6520019 1762<br />

FID Amplifier<br />

Required for use with<br />

FID Detector Add-On Kit.<br />

Auto-Ignite FID<br />

Replacement Parts<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

9<br />

Part No.<br />

Each (€)<br />

N6120162 754<br />

Description Part No. Each (€)<br />

Collector Head Assembly N6100357 1161<br />

Silicone Rubber O-Ring* (not shown) 09902143 1<br />

Polarizer Nozzle N6103167 49<br />

Spring Washer 09907827 1<br />

Nozzle Insulator N6101085 59<br />

Nozzle Collector N6103175 55<br />

FID Jet Contact/Spring N6001204 10<br />

Jet Assembly N6100361 301<br />

FID Body N6100364 573<br />

Nozzle Assembly N6100430 199<br />

Detector Series Operation Kit<br />

TCD/FID Series Operation Kit<br />

Used to direct sample effluent<br />

from the TCD to the FID.<br />

PID/FID Series Operation Kit<br />

Used to direct sample effluent<br />

from the PID to the FID.<br />

FID Miscellaneous Accessories<br />

Description Part No. Each (€)<br />

Auto-Ignite Nozzle Replacement Tool N6103188 17<br />

For removing nozzle from auto-ignite FID body<br />

Auto-Ignite FID Catalytic Reactor Accessory N6120161 612<br />

Capillary Column Adapter N6120020 69<br />

For capillary column use with the<br />

FID 1/8 to 1/16 in. detector adapter<br />

Ceramic Column Cutter N9301376 59<br />

Cotton Applicators N9301272 4<br />

Detector Cover (Brown Color) N6103225 43<br />

Detector Cover (White Color) N6103151 43<br />

Eraser Brush-Pencil 09923078 64<br />

Jet Assembly N6100194 376<br />

Jet Replacement Tool N6101297 51<br />

1/4 in. nut driver for removing jet<br />

from auto-ignite FID body<br />

Quartz Wool N6102354 26<br />

Replacement Stainless Steel Glow Plug N6103089 9<br />

for Auto-ignite FID<br />

Septa, low bleed (pkg. 50)** N9302972 103<br />

1/4 in. Packed Column Adapter 00080100 172<br />

For use with 1/4 in. packed columns. 1/8 to 1/4 in.<br />

adapter fits both injector and detector ends<br />

** For more Septa see page 159.<br />

1<br />

*<br />

8<br />

Part No.<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

Each (€)<br />

N6120006 166<br />

Part No.<br />

Each (€)<br />

N6120059 293<br />

9<br />

132


Detectors<br />

Flame Ionization Detector (FID) External Igniter<br />

Add-On Kits<br />

2<br />

External Igniter FID with PPC Add-On Kit<br />

Kit includes detector, heater and sensor, heater block,<br />

igniter, programmable pneumatics, and controls for<br />

detector combustion gases. Requires but does not include<br />

FID amplifier (N6120162). The AutoSystem XL must be<br />

PPC ready. If not, PPC upgrade kit (N6120146) is required.<br />

(See page 166 for more information.) Installation by<br />

PerkinElmer Service is required, but not included.<br />

1<br />

*<br />

Voltage Part No. Each (€)<br />

120 V N6120120<br />

230 V N6120121 4489<br />

3<br />

4<br />

External Igniter FID Add-On Kit (Manual Pneumatics)<br />

Kit includes detector assembly with heater and sensor,<br />

heater block, igniter, hydrogen pressure regulator,<br />

and air needle valve. Requires, but does not include,<br />

FID amplifier board (N6120162).<br />

Voltage Part No. Each (€)<br />

120 V N6120010<br />

240 V N6120024 2516<br />

FID Amplifier<br />

Required for use with FID<br />

Detector Add-On Kit.<br />

Replacement Parts<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

9<br />

Part No.<br />

Each (€)<br />

N6120162 754<br />

Description Part No. Each (€)<br />

Collector Head Assembly N6100170 574<br />

*Collector Assembly O-Ring (not shown) 09902143 1<br />

Collector Cap N6101037 17<br />

Nozzle Insulator N6101085 59<br />

Nozzle Ring 09912223 1<br />

FID Nozzle N6101100 59<br />

FID Jet Contact N6001204 10<br />

Jet Assembly N6100038 147<br />

Polarizer Replacement Kit N9300089 65<br />

FID Body N6100037 682<br />

Collector Adapter, Teflon ® ** (not shown) N6101547 43<br />

** Note: If instrument was purchased prior to March 1993, the following<br />

items must also be ordered: one each of N6101546 and 09912223.<br />

9<br />

5<br />

6<br />

7<br />

8<br />

Detectors Gas Chromatography<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

133


Detectors<br />

Flame Ionization Detector (FID) Replacement Parts<br />

Gas Chromatography Detectors<br />

Catalytic Reactor Accessory<br />

The catalytic reactor converts CO and CO2 to methane<br />

conveniently and efficiently. The lower detection limit<br />

is extended to well below 0.1 ppm.<br />

The catalytic reactor consists of a special catalytic reactor<br />

base which replaces the FID base. The reactor body<br />

contains a quantity of catalyst held in place by a quartz<br />

wool plug.<br />

Kits include base assembly, reactor tube, and instructions.<br />

External Igniter FID Catalytic<br />

Reactor Accessory<br />

Auto-Ignite FID Catalytic<br />

Reactor Accessory<br />

Catalytic Reactor Replacement Parts<br />

Description Part No. Each (€)<br />

Catalyst N9302698 55<br />

Jet Assembly N6100194 376<br />

Quartz Wool N6102354 26<br />

Catalyst<br />

Part No.<br />

Each (€)<br />

N6120070 810<br />

Part No.<br />

FID Base<br />

Each (€)<br />

N6120161 612<br />

Miscellaneous Accessories<br />

External Ignite Nozzle Replacement Tool<br />

For removing nozzle from<br />

External Ignite FID body.<br />

Hydrogen Regulator<br />

Replacement Kit<br />

Hydrogen/Air Replacement<br />

Needle Valve<br />

Igniter Assembly<br />

Complete replacement igniter<br />

assembly with glow plug.<br />

Replacement Glow Plug<br />

for External Ignite FID<br />

FID Flow Measurement Adapter<br />

Part No.<br />

Each (€)<br />

N6100102 125<br />

Part No.<br />

Each (€)<br />

N6100289 548<br />

Part No.<br />

Each (€)<br />

N6101412 396<br />

Part No.<br />

Each (€)<br />

N6100016 191<br />

Part No.<br />

Each (€)<br />

00091279 6<br />

Part No.<br />

Each (€)<br />

N6101345 29<br />

134


Detectors<br />

Flame Photometric Detector (FPD)<br />

Add-On Kits<br />

The FPD is a highly sensitive and selective detector for both<br />

sulfur and phosphorus compounds. It is especially suitable<br />

for environmental monitoring of H 2 S and sulfur gases in<br />

general and for organophosphorus compounds present at<br />

trace levels in pesticide analysis. Alkyl tin compounds can<br />

also be analyzed by changing the filter assembly. The sulfur<br />

filter is shipped standard.<br />

The FPD mounts in either the front or rear detector position.<br />

This allows many detector combinations, such as FPD/FPD,<br />

FPD/TCD, and FPD/ELCD.<br />

The AutoSystem also includes a linearizer function for the<br />

sulfur mode and convenient control of the photomultiplier<br />

tube from the keyboard.<br />

The FPD is capillary-column compatible. The detector will<br />

accept columns of 0.530 mm i.d. or less. The standard jet<br />

shipped with the FPD does not have a glass-lined tail pipe.<br />

If an all-glass system is required and glass packed columns<br />

will be used, then a glass-lined tail pipe should be ordered<br />

(N6100264). As a reminder, use of packed 1/4 in. columns<br />

requires a 1/8 to 1/4 in. adapter.<br />

Filters<br />

8<br />

Description Part No. Each (€)<br />

Phosphorus Lens (Yellow) N6000981 465<br />

Sulfur Lens* (Blue) N6000637 670<br />

Tin Lens (Orange) L4135472 721<br />

* Shipped standard.<br />

Filter Assembly<br />

5 2<br />

7<br />

Air<br />

1<br />

3<br />

4<br />

6<br />

Hydrogen<br />

FPD Add-On Kit (Manual Pneumatics)<br />

Kit includes detector, heater, sensor, heater block,<br />

hydrogen needle valve, air pressure regulator, and<br />

sulfur photomultiplier filter. Requires but does not<br />

include FPD amplifier (N6120095). Firmware revision<br />

1.6 or greater required. Firmware must be PerkinElmer<br />

Service installed. AutoSystem operator’s manual<br />

(09938559) revision E or higher required.<br />

Voltage Part No. Each (€)<br />

120 V AutoSystem N6120088<br />

240 V AutoSystem N6120089 8900<br />

120 V Clarus N6520028<br />

230 V Clarus N6520029 5400<br />

FPD Amplifier<br />

Firmware revision 1.6 or greater required. Firmware must<br />

be PerkinElmer Service installed. AutoSystem operator’s<br />

manual (09938559) revision E or higher required.<br />

FPD Replacement Parts for AutoSystem Series GCs<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

Description Part No. Each (€)<br />

O-Ring 09902247 2<br />

Seal Assembly and Window N9300096 105<br />

(heat shield)<br />

Liner (window) N6003057 34<br />

FPD Body (upper) N6100243 650<br />

Window Holder N6003066 22<br />

FPD Jet, N6100245 128<br />

Glass-lined Jet Tailpipe N6100264 376<br />

(for all-glass system)<br />

FPD Body (lower) N6100244 612<br />

Photomultiplier Tube 09972321 1256<br />

FPD with PPC Add-On Kit<br />

Kit includes detector, heater, sensor, heater block,<br />

programmable pneumatic control for detector combustion<br />

gases, and sulfur photomultiplier filter. Requires but does<br />

not include FPD amplifier (N6120095). AutoSystem XL GC<br />

must be PPC ready. If not, a PPC upgrade kit (N6120146)<br />

is required. (See page 166 for more information.)<br />

Installation by PerkinElmer Service is required,<br />

but not included.<br />

Voltage Part No. Each (€)<br />

120 V N6120128<br />

230 V N6120129 6700<br />

Packed Column Adapter<br />

1/8 to 1/4 in. adapter for use with<br />

1/4 in. packed columns. (Set of 2)<br />

Part No.<br />

Each (€)<br />

N6120095 660<br />

Part No.<br />

Each (€)<br />

00080100 172<br />

Detectors Gas Chromatography<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

135


Detectors<br />

Mass Spectrometer Detector<br />

The Clarus<br />

Mass Spectrometer<br />

The Clarus mass spectrometer is the fastest<br />

sampling and widest-mass-range quadrupole mass<br />

spectrometer available for GC/MS. State-of-the-art<br />

Pentium electronics process more scans across each<br />

peak, resulting in unmatched accuracy and precision,<br />

and better overall spectral fidelity. This, coupled<br />

with unique productivity tools, provides the<br />

functionality necessary to achieve optimum<br />

performance, completing work quickly, easily, and<br />

efficiently. The wide mass range and flexible data<br />

acquisition modes help tackle the most complex<br />

applications while rugged instrument design delivers<br />

maximum uptime, easy maintenance, and lower<br />

operating cost.<br />

Clarus Mass Spectrometer<br />

Combine the Clarus mass spectrometer with the<br />

Clarus gas chromatograph, market-leading<br />

TurboMatrix sample handling accessories, flexible<br />

user-friendly TotalChrom software, and worldclass<br />

service and support for an integrated,<br />

complete analytical solution from one familiar<br />

name – PerkinElmer. Whatever your application –<br />

Environmental, Chemical, Petrochemical, Flavor<br />

and Fragrance, Food, Beverage, Forensic,<br />

Pharmaceutical – PerkinElmer delivers the<br />

accuracy and precision you need.<br />

Flexible Column Choices<br />

Because the Clarus mass spectrometer allows a carrier gas flow of up to 5 mL<br />

per minute in EI, you have more column choices than with other GC/MS systems.<br />

Narrow-, medium-, and wide-bore columns can be used, with almost unlimited choice<br />

of stationary phase, diameter, and analytical method with Clarus mass spectrometer.<br />

Column Internal Diameter Typical Flows Clarus Mass Spectrometer Others<br />

Narrow-bore 0.10 to 0.18 mm i.d. 0.1 to 0.8 mL/min. X X<br />

Medium-bore 0.25 mm i.d 1 to 1.5 mL/min. X X<br />

Wide-bore* 0.32 to 0.53 mm i.d. 3 to 5 mL/min. X<br />

* Columns with low pneumatic impedance may require attachment of additional length of deactivated<br />

fused-silica capillary tubing to provide proper pressure drop from injector to mass spectrometer<br />

(Part Nos. N9301354, N9302149, and N9301343).<br />

Clarus Mass Spectrometer Benefits:<br />

■ Fastest Scan Rates – unprecedented speed with<br />

better chromatographic peak definition ensuring<br />

better quality results. Opens the use of quadrupole<br />

technology to fast GC applications.<br />

■ Widest Mass Range – uncompromised performance<br />

over a wide mass range.<br />

■ SIFI Scanning Mode – selected Ion Monitoring (SIM)<br />

and full scan in the same run resulting in the most<br />

complete characterization of the sample. No need<br />

to run the sample twice.<br />

■ Gold Component Technology – improved stability<br />

and reduced maintenance.<br />

■ Easy Access Ion Source – less than<br />

15-minute changeover.<br />

■ Sealed, Long-Life Photomultiplier – eliminates<br />

expensive replacement costs of electron multipliers.<br />

Better reliability.<br />

136


Detectors<br />

Mass Spectrometer Detector<br />

Cables<br />

Description Part No. Each (€)<br />

Cable, RS232, 7 ft. Length (185 cm) S5010025 46<br />

Personal Computer to AutoSystem XL Integral LINK<br />

(included with TurboMass Gold)<br />

Cable, RS232, 25 ft. Length (660 cm) S5010030 52<br />

Personal Computer to AutoSystem XL Integral LINK<br />

Computer to MS Cable E6400251 672<br />

For use with TurboMass Mass Spectrometers only<br />

Ethernet Cable 09991463 58<br />

For TurboMass Gold Mass and<br />

Clarus 500 Spectrometers only<br />

GC Start/Ready Cable E6400247 599<br />

GC to MS Interface Cable E6400242 1022<br />

Inner Source Replacement Parts<br />

Description Part No. Each (€)<br />

CI Ion Exit Plate E6401214 52<br />

Extra EI Electron Trap E6401220 137<br />

Extra CI Ion Volume E6401208 988<br />

Extra EI Ion Volume E6400211 1784<br />

Extra EI Repeller E6401219 242<br />

Ion Exit Plate E6401213 66<br />

Filament Assembly and Standard Tungsten Filament E6400209 220<br />

For use with TurboMass Spectrometers only<br />

Inner Source Heater Assembly E6400265 255<br />

Inner Source O-Ring Seal E5711272 22<br />

Inner Source Thumbscrew E6070836 6<br />

Standard Rhenium Filament N6470012 191<br />

Trap Contact E6401217 157<br />

Ionizer Replacement Parts<br />

Description Part No. Each (€)<br />

Clarus 500 and TurboMass Extra EI Inner source N6470207 2064<br />

Assembly (Tungsten)<br />

Clarus 500 and TurboMass Gold Extra EI Inner Ion E6400207 2171<br />

Source Assembly (Rhenium)<br />

Clarus 500 and TurboMass Gold Extra PCI/NCI E6400208 1615<br />

Inner Ion Source Assembly (Rhenium)<br />

Requires PCI or PCI/NCI configuration option<br />

Extra Outer Ion Source and Optics Assembly E6400206 4438<br />

Manuals<br />

Description Part No. Each (€)<br />

Clarus 500 MS Manual Set 09934562 179<br />

TurboMass Gold Manual Kit 09934472 257<br />

Includes: User’s Guide-EPCAS software,<br />

User’s Guide-EPCAS hardware, and TurboMass<br />

Gold Tutorial<br />

TurboMass Software User’s Manual S2701610 217<br />

TurboMass Hardware User’s Manual 09936341 96<br />

Miscellaneous Accessories<br />

BTO TM (Bleed Temperature Optimized) Injector Septa<br />

Maximum recommended operating<br />

temperature 300 °C. Low bleed,<br />

high temperature. 11 mm diameter.<br />

GC/MS Sensitivity Test Mix<br />

Includes standard solutions of benzophenone,<br />

hexachlorobenzene, and octafluoronaphthalene<br />

for testing instrument sensitivity.<br />

GC/MS Test Mix Triazine<br />

High molecular weight<br />

test standard. 100 mg.<br />

Forepump Vacuum Filter Kits<br />

Includes: Foreline Adsorption Trap (09923493), Nipple<br />

NW25 Extension Tube (09920864), NW25 Clamp Ring<br />

(09923491), NW25 Centering Ring (09923490), Installation<br />

Instructions (09936442), and<br />

Activated Alumina Reagentreplacement<br />

(09923504).<br />

Part No.<br />

E6420021<br />

Each (€)<br />

912<br />

Outlet Mist Filter<br />

Replacement Parts<br />

Description Part No. Each (€)<br />

Centering Ring 09923490 54<br />

Clamp 09923491 43<br />

Copper Tubing, Precleaned (50 ft.) N9300077 120<br />

FC-43 Tuning Compound N6212407 115<br />

Filament Allen Wrench 09907222 9<br />

Forepump Oil 09923492 117<br />

Gas Purifier for GC/MS N6471025 293<br />

Glass Bulb for Reference Gas E6401384 62<br />

Penning Gauge Spares Kit N6471031 1305<br />

Vacuum line (7 ft.) E6400223 1058<br />

Eraser Brush-Pencil 09923078 64<br />

Ceramic Column Cutter N9301376 59<br />

Cotton Applicators N9301272 4<br />

Septa, low bleed (pkg. 50)* N9302972 103<br />

* For more septa see page 159.<br />

Vent Kit<br />

Part No.<br />

Part No.<br />

Each (€)<br />

N9302972 103<br />

Each (€)<br />

E6401017 59<br />

Part No.<br />

Each (€)<br />

N9301730 107<br />

Part No.<br />

Each (€)<br />

09923518 643<br />

The Mass Spectrometer Vent Kit eliminates the introduction<br />

of oxygen, water vapor, and other airborne contaminants<br />

which can degrade sensitivity and performance of the mass<br />

spectrometer. The Clarus GCs should be vented with UHP<br />

nitrogen (99.9995%). Helium should not be used as Helium<br />

molecules penetrate the glass sleeve on the photomultiplier<br />

tube, compromising the vacuum<br />

and lowering sensitivity.<br />

Part No. Each (€)<br />

N6470045 446<br />

Detectors Gas Chromatography<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

137


Detectors<br />

Mass Spectrometer Detector<br />

Clarus MS<br />

TurboMass Single Additional Workstation License<br />

Allows TurboMass software to be run on one additional<br />

computer. Does not include manuals.<br />

Note: Network setup is the responsibility<br />

of the customer.<br />

Part No.<br />

S2701017<br />

Each (€)<br />

1512<br />

Wiley Mass Spectral Library<br />

Does not include the NIST library.<br />

Part No. Each (€)<br />

E6420003 6400<br />

Gas Chromatography Detectors<br />

MSVent Add-On Kit for the Clarus GC/MS<br />

Includes: all the necessary parts to add an MSVent<br />

accessory to a Clarus GC/MS. Requires a PreVent option<br />

(N6120144) to be already installed<br />

in the Clarus gas chromatograph. Part No. Each (€)<br />

Software<br />

TurboMass 5.1 Software Kit<br />

Includes: the TurboMass 5.1 software<br />

CD, TurboMass User’s Manual CD,<br />

and Utilities CD.<br />

Description Part No. Each (€)<br />

NIST Mass Spectral Library (2002) N6520220 2082<br />

NIST98 to 2002 Upgrade Kit N6520240 878<br />

Pfleger/Maurer/Weber Drug and Pesticide 04308523 4712<br />

Spectral Library<br />

TotalChrom Workstation Reprocess-Only Kit<br />

for TurboMass Mass Spectrometers Only<br />

N6120179 714<br />

Part No. Each (€)<br />

N6520206 1915<br />

Allows data collected from a conventional detector via<br />

TurboMass software to be analyzed with TotalChrom<br />

Workstation Chromatography Data System software.<br />

Includes: CD and 3.5 in. diskette<br />

media, user manuals, mouse pad,<br />

and installation instructions.<br />

Part No.<br />

S2701116<br />

Each (€)<br />

822<br />

Transfer Line<br />

Description Part No. Each (€)<br />

Transfer Line Carrier Tube E6401308 982<br />

Transfer Line O-Ring E5711269 11<br />

Transfer Lines 1/8 in. Nut E6401309 370<br />

Upgrade Kits<br />

EI to PCI/NCI Upgrade<br />

Includes: Cl ion source, reagent gas tubing, flow regulators,<br />

valves and solenoids, and dual-polarity electronic options.<br />

Installation by PerkinElmer Service<br />

is required, but not included.<br />

Part No. Each (€)<br />

TurboMass Gold Computer Upgrade<br />

Upgrade kit includes: Dell GX270 computer plus 17" flat<br />

panel monitor and Windows XP SP2.<br />

TurboMass 5.1 software is included free.<br />

Service installation is not required.<br />

Part No.<br />

N6470070<br />

Each (€)<br />

4285<br />

TurboMass Upgrade Kit<br />

E6420007 8600<br />

Upgrade kit includes: Dell GX270 computer with Windows<br />

XP SP2, 17" flat panel monitor, TurboMass 5.1 software<br />

and manual plus all necessary electronic and hardware<br />

components. Installation by a<br />

PerkinElmer Service professional<br />

is required, but not included.<br />

Part No.<br />

N6470080<br />

Each (€)<br />

10700<br />

138


Detectors<br />

Nitrogen Phosphorus Detector (NPD)<br />

Add-On Kits<br />

Replacement Parts<br />

NPD Add-On Kit (Manual Pneumatics)<br />

Description Part No. Each (€)<br />

The NPD can be used for the analysis of organic compounds<br />

containing nitrogen or phosphorus down to the picogram<br />

level. The NPD has become the detector of choice for<br />

low-level drug and pesticide applications because of its<br />

sensitivity and selectivity.<br />

Kit includes detector, heater, sensor, heater block, air<br />

needle valve, and hydrogen pressure regulator with snubber<br />

and two beads. Requires but does not include amplifier. For<br />

AutoSystem GC Firmware revision 1.4 or greater is required.<br />

Firmware must be PerkinElmer Service installed.<br />

Voltage Part No. Each (€)<br />

120 V AutoSystem N6120090<br />

240 V AutoSystem N6120091 5300<br />

120 V Clarus N6520024<br />

230 V Clarus N6520025 1730<br />

NPD Amplifier<br />

Required for use with<br />

NPD Add-On Kit.<br />

NPD with PPC Add-On Kit<br />

Kit includes detector, heater, sensor, heater block, and<br />

programmable pneumatic control for detector combustion<br />

gases and two beads. Requires but does not include amplifier<br />

(N6120094). The AutoSystem XL or Clarus GC must be PPC<br />

ready. If not, the PPC upgrade kit (N6120146) is required.<br />

(See page 166 for more information.) Installation by<br />

PerkinElmer Service is required, but not included.<br />

Voltage Part No. Each (€)<br />

120 V N6120126<br />

240 V N6120127 3045<br />

Column Adapter<br />

1/4 in. Packed Column Adapter<br />

1/8 to 1/4 in. detector receiver adapter<br />

for use with 1/4 in. packed columns.<br />

Two included (injector/detector).<br />

Part No.<br />

Part No.<br />

Each (€)<br />

N6120094 400<br />

Each (€)<br />

00080100 172<br />

1<br />

2<br />

3<br />

4<br />

Collector Head N6100253 574<br />

Bead Assembly (pkg. 5) N6120093 689<br />

Single pkg. N6120092 185<br />

Jet Assembly N6100038 147<br />

NPD Body N6100228 504<br />

Air in<br />

Hydrogen in<br />

1<br />

Column Connection<br />

2<br />

3<br />

4<br />

Detectors Gas Chromatography<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

139


Detectors<br />

Photoionization Detector (PID)<br />

Gas Chromatography Detectors<br />

Add-On Kits<br />

PID Add-On Kit (Manual Pneumatics)<br />

The PID utilizes a high-intensity ultraviolet light source to<br />

ionize the sample components eluting from the column in<br />

order to generate the chromatographic signal. The PID has<br />

a maximum recommended operating temperature of 250 °C.<br />

The lamp can be replaced with a blanking disk to allow<br />

bake-out operation (up to 350 °C).<br />

Kit includes detector, heater, sensor, makeup gas needle<br />

valve, and all necessary mounting hardware for installation<br />

on an AutoSystem GC. Requires but does not include<br />

amplifier (N6120061) and lamp power supply (N6120062).<br />

Firmware revision 1.2 or greater is required. Firmware must<br />

be PerkinElmer Service installed. AutoSystem operator’s<br />

manual (09908559) is required if not revision ƒ or higher.<br />

Voltage Part No. Each (€)<br />

120 V AutoSystem N6120047<br />

240 V AutoSystem N6120057 8900<br />

120 V Clarus N6520026<br />

230 V Clarus N6520027 7300<br />

PID Amplifier<br />

Required for use with<br />

PID Add-On Kit.<br />

PID Lamp Power Supply<br />

Required for use with<br />

PID Add-On Kit.<br />

PID with PPC Add-On Kit<br />

Part No.<br />

Each (€)<br />

N6120061 396<br />

Part No.<br />

Each (€)<br />

N6120062 398<br />

Kit includes detector, heater, sensor, heater block, and<br />

programmable pneumatic control for makeup gas. Requires<br />

but does not include amplifier (N6120061) and power<br />

supply (N6120062). The GC must be PPC ready. If not, a<br />

PPC upgrade kit (N6120146) is required. (See page 166 for<br />

more information.) Installation by PerkinElmer Service is<br />

required, but not included.<br />

Voltage Part No. Each (€)<br />

120 V N6120130<br />

230 V N6120131 12900<br />

Detector Series Operation Kits<br />

Description Part No. Each (€)<br />

PID/FID, PID/ECD N6120059 293<br />

Series kit for directing effluent<br />

from a PID to an FID or an ECD<br />

Miscellaneous Accessories<br />

Description Part No. Each (€)<br />

Bakeout Disk 03302989 62<br />

Lamp Cleaning Compound 03302775 172<br />

1/4 in. Detector Receiver 03300866 261<br />

1/8 in. Detector Receiver 03300865 261<br />

Replacement Lamps and Parts<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

Description Part No. Each (€)<br />

PID Lamp (10.2eV), For most applications 03303599 721<br />

including aromatics, alkenes, and aliphatics<br />

higher than C4. Shipped standard with PID<br />

PID Lamp (9.5eV), Improved selectivity for 03303598 593<br />

multiple ring aromatic, sulfur compounds<br />

PID Lamp Window Seal 03302778 47<br />

PID Lower Lamp Seal 03302777 79<br />

Shoulder Pin 03302976 110<br />

Cap Nut 03303773 46<br />

Base Assembly 03302979 2753<br />

Spring 03302973 13<br />

Cap with Harness<br />

N6101696<br />

5<br />

8<br />

7<br />

4<br />

1<br />

2<br />

3<br />

6<br />

140


Detectors<br />

Thermal Conductivity Detector (TCD)<br />

Add-On Kits<br />

■<br />

■<br />

■<br />

■<br />

Lower Internal Volume and Smaller Overall Size<br />

No Makeup Gas Required with 0.53 mm and 0.32 mm i.d.<br />

Capillary Columns<br />

Series Connection Option<br />

Excellent Sensitivity Over a Wide Dynamic Range<br />

TCD Add-On Kit (Manual Pneumatics)<br />

Kit includes all necessary items to install the TCD into the<br />

instrument: detector, heater, sensor, heater block, 1/16 in.<br />

gas line, and flow controller pneumatics. Requires, but does<br />

not include, amplifier (N6120015). The TCD can only be<br />

installed in the rear detector position.<br />

Voltage Part No. Each (€)<br />

120 V AutoSystem N6120012<br />

240 V AutoSystem N6120027 4260<br />

120 V Clarus N6520022<br />

230 V Clarus N6520023 2400<br />

TCD Amplifier<br />

TCD with PPC Add-On Kit<br />

Kit includes detector, heater, sensor, heater block, and<br />

programmable pneumatic control for reference gas. Requires<br />

but does not include amplifier (N6120015). The TCD can<br />

only be installed in the rear detector position. The GC must<br />

be PPC ready. If not, a PPC upgrade kit (N6120146) is<br />

required. (See page 166 for more information.) Installation<br />

by PerkinElmer Service is required, but not included.<br />

Voltage Part No. Each (€)<br />

120 V N6120124<br />

230 V N6120125 2827<br />

TCD with PPC Makeup Gas Kit<br />

Includes parts required to add PPC controlled makeup<br />

gas to an existing TCD. Includes tubing, tee-piece, PPC<br />

pneumatics module, and PPC frit #4<br />

(N6120155). Requires PPC capability<br />

in the GC.<br />

Part No.<br />

N6120150<br />

Each (€)<br />

1441<br />

Column Adapters<br />

Part No.<br />

Each (€)<br />

N6120015 610<br />

Description Part No. Each (€)<br />

1/8 to 1/4 in. 00080100 172<br />

Column adapter for use with 1/4 in.<br />

packed columns<br />

1/8 to 1/16 in. N6120020 69<br />

Column adapter for use with capillary columns<br />

Thermal Conductivity Detector<br />

TCD/FID Series Operation Kit<br />

TCD and FID series operation kit for<br />

directing effluent from a TCD to an FID.<br />

Part No.<br />

Each (€)<br />

N6120006 166<br />

TCD Detector Makeup Gas Kit (Manual Pneumatics)<br />

For use with TCD (at low flow rates). Required when using<br />

0.25 mm i.d. and recommended when using 0.32 mm i.d.<br />

capillary columns. Kit includes 1 m of 1/16 in. tubing to<br />

connect to gas supply, graphite/vespel<br />

ferrules, manual pneumatics,<br />

and installation instructions.<br />

Part No.<br />

N6120080<br />

Each (€)<br />

510<br />

Detectors Gas Chromatography<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

141


Headspace Accessories and Supplies<br />

Headspace <strong>Instruments</strong><br />

PerkinElmer TurboMatrix<br />

Headspace Samplers<br />

PerkinElmer TurboMatrix Headspace Samplers eliminate tedious and error-producing steps required<br />

in other GC sample preparation techniques, enabling you to analyze volatile compounds in less time.<br />

The intuitive touch-screen graphical user interface provides easy control of the sampler.<br />

TurboMatrix 16<br />

TurboMatrix 40<br />

TurboMatrix<br />

Headspace Trap<br />

The TurboMatrix Headspace (HS)<br />

system is fully self-contained and<br />

can be interfaced to almost any gas<br />

chromatograph, giving you access to<br />

PerkinElmer’s proven headspace<br />

technology, regardless of the brand or<br />

model GC you have in your laboratory.<br />

The TurboMatrix system maximizes<br />

sample throughput. The system can<br />

simultaneously thermostat up to 12<br />

samples, ensuring that the next sample<br />

is always ready for analysis upon<br />

completion of the previous run. This<br />

adds up to a significant time saving since<br />

there is no need to wait for the next<br />

sample to heat.<br />

Volatile compounds in almost any<br />

sample matrix can be analyzed simply<br />

and quickly by headspace gas<br />

chromatography. Only PerkinElmer<br />

headspace samplers utilize a pneumaticpressure-balanced<br />

system, a proven<br />

technology that’s been used in all<br />

PerkinElmer headspace samplers for<br />

more than 35 years. This unique,<br />

patented technique provides higher<br />

sensitivity and better performance<br />

than alternative techniques.<br />

The pressure-balanced sampling technique:<br />

■<br />

■<br />

■<br />

■<br />

■<br />

Produces sharper peaks by rapidly transferring<br />

a narrow sample band to the GC column.<br />

Increases sensitivity since there is no carrier gas<br />

dilution of sample.<br />

Avoids fractionation due to pressure changes<br />

in the syringe.<br />

Eliminates multiport valves that are prone to<br />

adsorption and may introduce dead volumes.<br />

Provides exceptional reproducibility equal to that<br />

obtainable with liquid.<br />

The TurboMatrix system is available<br />

in your choice of entry-level, mid-range,<br />

or high-capacity systems. And, since<br />

upgradeability is built in, you can adapt<br />

your system to changing requirements<br />

by upgrading from one model to the<br />

next or adding accessories that provide<br />

more capabilities.<br />

142


Headspce Add-On Kits<br />

Cryofocusing Add-On Kit, TurboMatrix HS<br />

Adds cryofocusing capability to a TurboMatrix 40 or<br />

TurboMatrix 110 headspace sampler. Includes water trap<br />

to remove the water from headspace samples taken from<br />

aqueous solutions. Note: Requires but does not include,<br />

LN2 Dewar (B0500924). Also requires, but does not include,<br />

an options board to be installed in the TurboMatrix 40<br />

headspace sampler. Installation<br />

by PerkinElmer Service is required, Part No. Each (€)<br />

but not included.<br />

M0413550 3941<br />

HS 40XL Cryofocusing Accessory (White Color)<br />

Consists of cryofocusing module, firmware, required tubing<br />

unions, and water trap to be installed in AutoSystem GC.<br />

Requires liquid nitrogen storage tank.<br />

Installation by PerkinElmer Service<br />

is required, but not included.<br />

Part No.<br />

N1010047<br />

Each (€)<br />

2716<br />

Replacement Water Trap<br />

for Cryofocusing Accessory<br />

Options Board/BCD Output Board, TurboMatrix HS<br />

Required for installation of the following options on<br />

the TurboMatrix 40 headspace sampler – Vial Shaker<br />

and Cryofocusing – and when upgrading a TurboMatrix<br />

16 or 40 headspace sampler to a TurboMatrix 110. Also<br />

provides output of BCD information regarding tube position<br />

numbers and six relays for timed control of external<br />

devices. Installation by PerkinElmer Service is required, but<br />

not included. (Fitted as standard<br />

on TurboMatrix 110 HS).<br />

Part No. Each (€)<br />

HS 40 Options Board<br />

Allows up to six optional control ICs.<br />

Installation by PerkinElmer Service<br />

is required, but not included.<br />

TurboMatrix Headspace PPC Add-On Kit<br />

Includes parts to convert a headspace sampler from manual<br />

pneumatics to electronic Programmable Pneumatic Control<br />

(PPC). Installation by PerkinElmer<br />

Service is required, but not included. Part No. Each (€)<br />

Headspace Accessories and Supplies<br />

Part No.<br />

Each (€)<br />

B4000057 402<br />

M0413551 988<br />

Part No.<br />

Each (€)<br />

B0184142 261<br />

M0413548 3418<br />

Vial Shaker Add-On Kit,<br />

Headspace and Headspace Trap<br />

HS 40XL Shaker Accessory Add-On Kit<br />

Add-On Kits<br />

Adds a Frequency Scanning Shaker to a TurboMatrix 40<br />

or TurboMatrix 110 headspace sampler. Note: Requires,<br />

but does not include, an options board to be installed in<br />

the TurboMatrix 40 headspace sampler. Installation by<br />

PerkinElmer Service is required,<br />

but not included.<br />

Part No. Each (€)<br />

M0413549 1314<br />

Adds Frequency Scanning Shaker to vibrate all samples in<br />

thermostatting chamber. Installation by PerkinElmer Service<br />

is required, but not included.<br />

Color Part No. Each (€)<br />

Blue N1010050 4336<br />

Red B0505475 3941<br />

Headspace Accessories and Supplies Gas Chromatography<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

143


Gas Chromatography Headspace Accessories and Supplies<br />

Headspace Accessories and Supplies<br />

Headspace Accessories<br />

Miscellaneous Accessories<br />

TurboMatrix HS Standard Length<br />

Heated Transfer Line (960 mm)<br />

For operation up to 210 °C.<br />

TurboMatrix HS/HS Trap Long<br />

Heated Transfer Line (1650 mm)<br />

For operation up to 210 °C.<br />

Fused–Silica Capillary Transfer Line<br />

Tube i.d. (mm) Length (m) Part No. Each (€)<br />

0.25 5 N9301356 37<br />

0.32 5 N9301357 37<br />

Siltek Deactivated Fused Silica Transfer Line<br />

Tube i.d. (mm) Length (m) Part No. Each (€)<br />

0.25 5 N9316607 70<br />

0.32 5 N9316608 77<br />

Zero Dilution Inner Liner<br />

To be used with zero dilution outer liner. The powerful<br />

zero dilution liner combination allows you to achieve lower<br />

detection limits, sharpen peak shape, and increase throughput<br />

for many routine analyses. Installed in an AutoSystem Series<br />

or Clarus GC standard capillary or PSS injector, this optional<br />

special hourglass insert connects the fused-silica transfer<br />

line from the headspace sampler to the capillary column,<br />

permitting undiluted and efficient sample transfer. The<br />

insert provides the advantages of a<br />

direct connection, while maintaining Part No. Each (€)<br />

the capability to perform split injections.<br />

N1011446 41<br />

Zero Dilution Capillary Injector Outer Liner<br />

To be used with zero dilution inner liner. The powerful<br />

zero dilution liner combination allows you to achieve lower<br />

detection limits, sharpen peak shape, and increase throughput<br />

for many routine analyses. Installed in an AutoSystem Series<br />

or Clarus GC standard capillary injector, this optional special<br />

hourglass insert connects the fused-silica transfer line from<br />

the headspace sampler to the capillary column, permitting<br />

undiluted and efficient sample transfer. The insert provides<br />

the advantages of a direct connection,<br />

while maintaining the convenience of Part No. Each (€)<br />

using a split injector as an interface.<br />

N1011445 74<br />

Zero Dilution PSS<br />

Injector Outer Liner<br />

Part No.<br />

Gas Chromatography – Theory and Practice,<br />

Static Headspace Book by L. Ettre and B. Kolb<br />

Each (€)<br />

M0413643 1314<br />

Part No.<br />

Each (€)<br />

M0413552 2168<br />

Part No.<br />

Part No.<br />

Each (€)<br />

N1011447 90<br />

Each (€)<br />

N1011210 153<br />

TurboMatrix HS Trap Cold Trap Tube (Carbotrap C)<br />

Standard cold trap (M0410094)<br />

packed with Carbopack C.<br />

O-Ring<br />

7 mm<br />

TurboMatrix Headspace<br />

Sampler User’s Manual<br />

Cool Platen<br />

For storage of vials below ambient down to +5 °C. Contains<br />

cool platen and tubing. Requires a thermostatted external<br />

cooling circulation water bath. Installation by PerkinElmer<br />

Service is required, but not included.<br />

Note: Requires, but does not include,<br />

Cryostat Liquid Immersion Cooler.<br />

Part No.<br />

B0500778<br />

Each (€)<br />

2270<br />

Extended Transfer Line (1650 mm HS 40/40XL)<br />

Extra-long transfer line to allow installation of HS 40XL on<br />

the right side of the AutoSystem Series/Clarus GC or to any<br />

gas chromatograph where the HS 40XL<br />

is situated at an extended distance. Part No. Each (€)<br />

High Pressure Sampling Accessory<br />

Used for operation with capillary columns requiring a<br />

low head pressure. Also used for carrier gas flow control.<br />

Accessory includes high-pressure sampling module with<br />

pressure regulator, gauge, firmware, tubing, and unions.<br />

Installation by PerkinElmer Service<br />

is required, but not included.<br />

Part No. Each (€)<br />

Note: Requires, but does not include, Options Board.<br />

HS 40XL to AutoSystem Series<br />

Left Side Mounting Kit (White Color)<br />

For connecting the HS 40XL transfer line through the left<br />

side of the AutoSystem XL GC directly to the column in the<br />

oven instead of via the injection port. Includes a new GC<br />

side panel and parts for attaching the transfer line to the<br />

GC. Requires, but does not include, some type of zero dead<br />

volume connector to connect to the column (for example,<br />

a universal capillary column connector,<br />

N9302149). Installation by PerkinElmer Part No. Each (€)<br />

Service is recommended.<br />

N1010048 510<br />

HS 40XL Instruction Manual<br />

Part No.<br />

Each (€)<br />

N6200150 317<br />

Part No.<br />

Each (€)<br />

09200091 30<br />

Part No.<br />

Each (€)<br />

M0413401 93<br />

B4000046 2168<br />

B0505271 3278<br />

Part No.<br />

Each (€)<br />

09935404 73<br />

144


Internal Carrier Gas Pressure Control<br />

For carrier gas control. Includes regulator, gauge, tubing, and<br />

unions. Installation by PerkinElmer<br />

Service is required, but not included. Part No. Each (€)<br />

Recycle Mode Accessory<br />

Continuously repeats sequence with setup method. Installation<br />

by PerkinElmer Service is required, but not included.<br />

Note: Requires, but does not include, Options Board.<br />

Remote Control Software (RCS)<br />

HS 40XL Control Software<br />

Windows ® -based, flexible, easy-to-use external control software<br />

for the HS 40 and HS 40XL. The user can develop and store<br />

methods and sequences. Run reports can be obtained, stored,<br />

and printed. On-screen, context sensitive help available. Can<br />

be operated in combination with PerkinElmer TotalChrom TM<br />

Software. Requires RS-232<br />

Interface for the HS 40XL.<br />

Part No. Each (€)<br />

TurboMatrix HS PC (RCS) v1.1 for WIN NT<br />

NOTE: This software version is only supported under Windows ® NT4.0 Service<br />

Pack 6a. Windows 2000 users should order Version 1.2 (see Part Number<br />

N6200200 below). This software requires the HS unit to have firmware<br />

version 1.87 or earlier. Provides full external control of a TurboMatrix<br />

headspace sampler from a personal computer running under Windows 95, 98<br />

or NT. Methods and sequences can be generated, stored, edited, printed and<br />

executed. Functions include setup, diagnostics, user<br />

defined access levels and run reports. On-screen Part No. Each (€)<br />

interactive help function is available. Cable included.<br />

M0413348 822<br />

TurboMatrix HS PC (RCS) v1.2 for WIN 2000<br />

NOTE: This software requires the HS unit to have firmware version 1.87 or<br />

earlier. Provides full external control of a TurboMatrix headspace sampler<br />

from a personal computer running under Windows 2000 SP2. Methods and<br />

sequences can be generated, stored, edited, printed and executed. Functions<br />

include setup, diagnostics, user defined access<br />

levels and run reports. On-screen interactive help<br />

function is available. Cable included.<br />

Part No.<br />

N6200200<br />

Each (€)<br />

819<br />

Headspace Accessories and Supplies<br />

B0505268 1314<br />

Part No.<br />

Each (€)<br />

B0197336 606<br />

B0510984 844<br />

TurboMatrix HS Trap PC (RCS) v2.0<br />

Headspace Accessories<br />

NOTE: This software requires the HS unit to have firmware version 2.00.<br />

Provides full external control of a TurboMatrix headspace sampler from a<br />

personal computer running under Windows XP SP1 or Windows 2000 SP3.<br />

Methods and sequences can be generated, stored, edited, printed and executed.<br />

Functions include setup, diagnostics, user defined access levels and run<br />

reports. Includes control of the TurboMatrix Trap if present on the HS unit. Onscreen<br />

interactive help function is available. Cable included. RCS version 2.0<br />

is available for those who do not wish to update from TotalChrom (TC) 6.2.1<br />

and/or for those who need to use a TurboMatrix<br />

HS unit with revision 2.0 or lower firmware.<br />

Part No. Each (€)<br />

Sample Trays<br />

TurboMatrix 40 Mid-Range Sample Tray<br />

40-position sample tray for use on<br />

the mid-range headspace sampler.<br />

TurboMatrix 110 High-Capacity Sample Tray<br />

110-position sample tray for use on<br />

the high-capacity headspace sampler.<br />

Tools<br />

O-Ring Removal Tool<br />

For replacing O-Rings in upper<br />

and lower seal assemblies.<br />

Headspace Vial Gauge<br />

Used to check 20 mL headspace<br />

vials for correct dimensions.<br />

Adapter Sleeve Torsion Bar<br />

For loosening upper seal.<br />

Thumbscrew Removal Tool<br />

For removing lower seal assembly.<br />

Spigot Key<br />

For loosening lower seal.<br />

Open End Wrench, 1/4 - 5/16 in.<br />

For use in mounting the Transfer Line.<br />

N6700200 745<br />

Part No.<br />

Part No.<br />

Each (€)<br />

B0147449 20<br />

Part No.<br />

Each (€)<br />

B0151737 102<br />

Part No.<br />

Each (€)<br />

B0135485 26<br />

Part No.<br />

Each (€)<br />

B0131410 20<br />

Part No.<br />

Each (€)<br />

B0500843 39<br />

Part No.<br />

Each (€)<br />

M0413592 112<br />

Part No.<br />

Each (€)<br />

M0413593 332<br />

Each (€)<br />

09907233 23<br />

Headspace Accessories and Supplies Gas Chromatography<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

145


Gas Chromatography Headspace Accessories and Supplies<br />

Headspace Accessories and Supplies<br />

Headspace Accessories<br />

Open End Wrench, Sw-7<br />

Transfer Line End Cap<br />

PE Injector Transfer Line Adapter<br />

TurboMatrix and HS 40XL<br />

Adapter Kits for Non-PerkinElmer<br />

Gas Chromatographs<br />

All kits include a Modified Septum Nut Adapter and the instructions for<br />

physical installation and interfacing of the two instruments. Use the standard<br />

PerkinElmer cables (N1011206, 2 needed) for ready/run connections.<br />

Headspace Adapter Kit for Carlo Erba<br />

For connecting a TurboMatrix or HS 40<br />

(XL) headspace sampler to a Carlo Erba<br />

Mega or Vega gas chromatograph.<br />

Headspace Adapter Kit for Fisons Series 8000<br />

For connecting a TurboMatrix or HS<br />

40 (XL) headspace sampler to a Fisons<br />

Series 8000 gas chromatograph.<br />

Headspace Adapter Kit for Gerstel CIS Injector<br />

For connecting a TurboMatrix or HS 40 (XL) headspace<br />

sampler to a Gerstel Cooled Injector System Inlet. As the<br />

Gerstel injector can be installed on several GC models,<br />

customer should contact the GC<br />

manufacturer for the appropriate<br />

“Remote Start/Stop Cable.”<br />

Part No.<br />

B0506539<br />

Each (€)<br />

198<br />

Headspace Adapter Kit for HP 6890,<br />

HP 6850, or HP 5890 On-Column<br />

Part No.<br />

Part No.<br />

Each (€)<br />

B0506603 147<br />

Part No.<br />

Each (€)<br />

B0510251 10<br />

Part No.<br />

Each (€)<br />

B0510403 53<br />

Part No.<br />

Each (€)<br />

B0505266 186<br />

Each (€)<br />

B4000012 140<br />

For connecting a TurboMatrix or HS 40 (XL) headspace<br />

sampler to an on-column injector of an HP 6890, HP 6850,<br />

HP 5890, or HP 5890 Series 2 gas chromatograph.<br />

Note: Installation on HP 6890 and HP 6850 requires a TurboMatrix/HS 40 (XL)<br />

to HP 6890/6850 GC Ready/Start Cable (N610-0410). For installation on<br />

HP 5890, customer should contact Hewlett-Packard<br />

for the appropriate “Remote Start/Stop Cable.” Part No. Each (€)<br />

B0507944 140<br />

Headspace Adapter Kit for Shimadzu<br />

For connecting a TurboMatrix or HS 40 (XL) headspace<br />

sampler to the following Shimadzu gas chromatographs:<br />

GC 9a for capillary columns, 14A<br />

packed columns, 14B packed columns,<br />

17A packed, and capillary columns.<br />

Part No.<br />

B0505889<br />

Each (€)<br />

140<br />

Headspace Adapter Kit for Shimadzu GC14A/B<br />

For connecting a TurboMatrix or HS 40 (XL) headspace<br />

sampler to a Shimadzu GC 14A/14B gas<br />

chromatograph with capillary columns. Part No. Each (€)<br />

Headspace Adapter Kit for Shimadzu GC16<br />

For connecting a TurboMatrix or<br />

HS 40 (XL) headspace sampler to a<br />

Shimadzu GC 16 gas chromatograph.<br />

Headspace Adapter Kit for Thermo Trace GC<br />

For connecting a TurboMatrix or<br />

HS 40(XL) headspace sampler to a<br />

Thermo Trace gas chromatograph.<br />

Headspace Adapter Kit<br />

for Varian Capillary Column Injector<br />

For connecting a TurboMatrix or HS 40(XL) headspace<br />

sampler to a Varian 3400 or 3800 gas chromatograph<br />

capillary column injector. Customer<br />

should contact Varian for the<br />

appropriate “Remote Start/Stop Cable.”<br />

Part No.<br />

N6201001<br />

Each (€)<br />

168<br />

Headspace Adapter Kit<br />

for Varian Packed Column Injector<br />

For connecting a TurboMatrix or HS 40(XL) headspace<br />

sampler to a Varian 3400 or 3800 gas chromatograph<br />

packed column injector. Customer<br />

should contact Varian for the<br />

appropriate “Remote Start/Stop Cable.”<br />

Part No.<br />

B0505978<br />

Each (€)<br />

140<br />

Headspace Adapter Kit for Varian/Finnigan ITS40<br />

For connecting a TurboMatrix or<br />

HS 40(XL) headspace sampler to a<br />

Varian/Finnigan ITS40 GC/MS System.<br />

Installation Instructions: Headspace to<br />

Non-PerkinElmer Gas Chromatographs<br />

B4000033 147<br />

Part No.<br />

Each (€)<br />

B0508521 147<br />

Part No.<br />

Each (€)<br />

N6201030 143<br />

Part No.<br />

Each (€)<br />

B0507942 217<br />

Instructions for physical installation and interfacing<br />

of the TurboMatrix or HS 40(XL) headspace sampler<br />

to non-PerkinElmer GCs.<br />

Note: This kit is intended for GC’s not listed above.<br />

Part No. Each (€)<br />

B0508738 77<br />

146


TurboMatrix Headspace to HP 6890<br />

GC Ready Start Cable<br />

Connects a TurboMatrix Headspace Sampler to an<br />

HP 6890 or HP 6850 GC.<br />

Note: Customer should contact gas chromatograph manufacturer for the<br />

appropriate “Remote Start/Stop Cable.”<br />

Part No. Each (€)<br />

Start/Ready Cables<br />

Description Part No. Each (€)<br />

HS 40XL to Agilent 6890 GC N6100410 149<br />

For all PerkinElmer GCs and HP 5890 (2 needed) N1011206 35<br />

TurboMatrix Headspace/HS 40/<br />

HS 40XL Replacement Parts<br />

and Needle Identification<br />

Needle Identification<br />

The number of rings engraved into the needle top<br />

in various types of needles.<br />

Number of Rings Number of Rings<br />

Needle Type for Stainless Steel for Platinum Iridium<br />

Wide-Bore none 1<br />

Small-Bore none 2<br />

Jet 3 4<br />

Replacement Parts<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

9<br />

Headspace Accessories and Supplies<br />

N6100410 149<br />

Description Part No. Each (€)<br />

Platinum/Iridium Needle, Wide-Bore B0144169 2371<br />

Platinum/Iridium Needle, Small-Bore B0500959 2032<br />

Platinum/Iridium Needle, Jet B0510364 1084<br />

Silcosteel Needle, for Headspace Trap Only N6700130 994<br />

Stainless Steel Needle, Wide-Bore B0131385 268<br />

Stainless Steel Needle, Small-Bore B0500987 1024<br />

Stainless Steel Needle, Jet (ships with instrument) B4000011 547<br />

Needle Seal Assembly (without O-Rings) B0500833 74<br />

O-Ring for Needle Seal Assembly (pkg. 10) B0198110 42<br />

Vespel Ferrule 1⁄16 in. (pkg. 10) 09920127 84<br />

Male Nut 1⁄16 in. N9302832 5<br />

GLT Adapter Tube B0503956 207<br />

GLT Adapter Tube, Silcosteel N6700113 529<br />

Graphite/Vespel Ferrule 1⁄16 in. x 0.4 mm 09920104 84<br />

(for use with 0.25 mm i.d. transfer line, pkg. 10)<br />

Graphite/Vespel Ferrule 1⁄16 in. x 0.5 mm 09903700 48<br />

(for use with 0.32 mm i.d. transfer line, pkg. 10)<br />

Nut 1⁄ 16 in. Swagelok N9300059 54<br />

Fused-Silica Capillary Transfer Line:<br />

0.25 mm i.d. x 5 m length N9301356 37<br />

0.32 mm i.d. x 5 m length N9301357 37<br />

TurboMatrix Upgrade Kits<br />

Headspace Accessories<br />

TurboMatrix 16 to 40 Upgrade Kit (Headspace Only)<br />

Includes parts to upgrade an entry-level headspace sampler<br />

to a mid-range headspace sampler that can perform automated<br />

analysis of up to 40 vials with overlapping themostatting of<br />

up to 12 vials. Installation by<br />

PerkinElmer Service is required,<br />

but not included.<br />

Part No.<br />

M0413545<br />

Each (€)<br />

5300<br />

TurboMatrix 16 to 110 Upgrade Kit (Headspace Only)<br />

Includes parts to upgrade an entry-level headspace sampler<br />

to a high-capacity headspace sampler that can perform<br />

automated analysis of up to 110 vials with overlapping<br />

themostatting of up to 12 vials.<br />

Installation by PerkinElmer Service<br />

is required, but not included.<br />

Part No.<br />

M0413546<br />

Each (€)<br />

18400<br />

TurboMatrix 40 to 110 Upgrade Kit<br />

(Headspace and Headspace Trap)<br />

Includes parts to upgrade a mid-range headspace sampler<br />

to a high-capacity headspace sampler that can perform<br />

automated analysis of up to 1100 vials with overlapping<br />

themostatting of up to 12 vials.<br />

Installation by PerkinElmer Service<br />

is required, but not included.<br />

Part No.<br />

M0413547<br />

Each (€)<br />

15100<br />

Note: Requires, but does not include, an options board (M0413551) to be installed<br />

in the headspace sampler. Installation by PerkinElmer Service is required,<br />

but not included.<br />

9<br />

8<br />

7<br />

6 5<br />

4<br />

1<br />

2<br />

3<br />

2<br />

3<br />

Headspace Accessories and Supplies Gas Chromatography<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

147


Gas Chromatography Headspace Accessories and Supplies<br />

Headspace Accessories and Supplies<br />

Headspace Vials, Caps, and Septa<br />

Headspace Caps and Septa<br />

Patented safety springs and caps designed to<br />

release at vial headspace pressures above 73 psi.<br />

Aluminum-Coated Silicone<br />

Rubber Headspace Septa<br />

Includes caps and starsprings<br />

(19 mm diameter). Maximum<br />

temp. 120 °C.<br />

Description Part No. Each (€)<br />

pkg. 100 B0104243 101<br />

pkg. 1000 B0104244 906<br />

pkg. 1000 (preassembled) B4000028 952<br />

Butyl Rubber Headspace Septa<br />

Includes caps and starsprings<br />

(19 mm diameter). Maximum<br />

temp. 100 °C.<br />

Description Part No. Each (€)<br />

pkg. 100 B0159356 51<br />

pkg. 1000 B0159357 460<br />

pkg. 1000 (preassembled) N1010070 507<br />

PTFE-Coated Butyl Rubber<br />

Headspace Septa<br />

Includes caps and starsprings<br />

(19 mm diameter). Maximum<br />

temp. 100 °C.<br />

Description Part No. Each (€)<br />

pkg. 100 B0104239 68<br />

pkg. 1000 B0104240 614<br />

pkg. 1000 (preassembled) B4000025 645<br />

PTFE-Coated Silicone Rubber<br />

Headspace Septa<br />

Includes caps and starsprings<br />

(19 mm diameter). Maximum<br />

temp. 210 °C.<br />

Description Part No. Each (€)<br />

pkg. 100 B0104241 86<br />

pkg. 1000 B0104242 772<br />

pkg. 1000 (preassembled) B4000022 810<br />

Headspace Septa Recommended<br />

Temperature Chart<br />

Upper Temperature<br />

Material Limit at Vial Inertness<br />

Butyl Rubber 100 °C Poor<br />

PTFE-Coated Butyl Rubber 100 °C Good<br />

Aluminum-Coated Silicone 120 to 210 °C Good<br />

PTFE-Coated Silicone 210 °C Good<br />

Headspace Vials<br />

Headspace Starter Kit<br />

Consisting of 1000 vials (B0104236), two sets of septa,<br />

each with aluminum caps and starsprings: 200 PTFE-coated<br />

butyl rubber septa (B0104239), 200 PTFE-coated silicon<br />

rubber septa (B0104241). Also included are: hand crimper<br />

(N9302785), pressure gauge with needle for vials<br />

(B0501377), two needle seal assemblies (B0500833),<br />

10 O-Rings (B0198110), and a book by B. Kolb and L.S.<br />

Ettre, Static Headspace Gas Chromatography Theory and<br />

Practice (N1011210).<br />

Part No. Each (€)<br />

Headspace Safety Sample Vials<br />

B0505601 1339<br />

Description Part No. Each (€)<br />

pkg. 1000 B0104236 370<br />

148


Vial Crimping Tools<br />

Benchtop Crimper<br />

The PerkinElmer Benchtop Crimper with interchangeable<br />

jaws provides a fast and consistent crimp on each vial, every<br />

time. Once crimping pressure is set, the lever action will<br />

repeatedly afford the user a perfectly crimped vial, with little<br />

effort. Jaws and decrimping jaws are available for 11 mm<br />

and 20 mm crimp caps.<br />

Description Part No. Each (€)<br />

Benchtop Crimper with 20 mm Jaw N6620065 1685<br />

Benchtop Crimper without Jaws N6621006 1685<br />

Jaws for Benchtop Crimper, 11 mm N6621008 391<br />

Jaws for Benchtop Crimper, 20 mm N6621009 344<br />

Headspace Accessories and Supplies<br />

Headspace Vials, Caps, and Septa<br />

Electronic Crimpers<br />

New from PerkinElmer, the 20 mm electronic crimpers<br />

and decappers are easy to use and fully rechargeable.<br />

Ergonomically designed to alleviate the potential for Carpal<br />

Tunnel Syndrome and provide a consistent crimp pressure<br />

numerous times. The electronic crimper is provided with<br />

a standard Black and Decker VeraPak ® Gold battery and<br />

charging unit. This hand-held device will crimp several<br />

hundred vials from one charge. Crimping pressure is fully<br />

adjustable for precision control. Also available in 11 mm.<br />

See page 90.<br />

Features and Benefits:<br />

■ Precision control crimping<br />

■ Ergonomically designed grip<br />

■ Numerous reproducible crimps from a single charge<br />

■ Includes standard Black and Decker VersaPak Gold<br />

battery and charger<br />

Description Part No. Each (€)<br />

20 mm Electronic Hand Crimper, 120 V N9302571<br />

20 mm Electronic Hand Crimper, 200 V N9302572 700<br />

20 mm Electronic Hand Crimper, 230 V N9302573 700<br />

20 mm Electronic Hand Crimper, 240 V N9302574 700<br />

20 mm Electronic Hand Decapper, 120 V N9302579<br />

20 mm Electronic Hand Decapper, 200 V N9302580 700<br />

20 mm Electronic Hand Decapper, 230 V N9302581 700<br />

20 mm Electronic Hand Decapper, 240 V N9302585 700<br />

Electronic Crimper Battery N9302582 44<br />

Hand Crimpers<br />

Hand Crimper<br />

Part No. N9302571<br />

Description Part No. Each (€)<br />

Hand Held Crimper, 20 mm N9302785 256<br />

Hand Held Decapper, 20 mm N9301270 64<br />

Headspace Accessories and Supplies Gas Chromatography<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

149


Injectors<br />

Capillary Injectors<br />

Injector Replacement Parts<br />

Components Part No. Each (€)<br />

Gas Chromatography Injectors<br />

18<br />

Manual Gas Control<br />

11<br />

17<br />

6<br />

1<br />

2<br />

3<br />

4<br />

6<br />

8<br />

10<br />

14<br />

15<br />

16<br />

19<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

8<br />

10<br />

11<br />

12<br />

13<br />

14<br />

15<br />

16<br />

17<br />

18<br />

19<br />

Injector Cover N6101482 21<br />

Septum Cap N6100153 96<br />

Thermogreen TM Septum (pkg. 50)* N6621028 202<br />

Injector Top Nut N6101358 96<br />

Injector Head N6100158 421<br />

O-Ring, Silicone for Glass Liner (pkg. 10) N6101374 9<br />

Maximum injector temperature 250 °C,<br />

O-Ring, Graphite for Glass Liner (pkg. 5) N6101378 21<br />

Maximum injector temperature 450 °C.<br />

O-Ring, KALREZ ® for Glass Liner (pkg. 1) N9302782 37<br />

Maximum injector temperature 450 °C.<br />

O-Ring, Viton ® for Glass liner (pkg. 1) N9302783 4<br />

Maximum injector temperature 250 °C,<br />

recommended for use with Mass Spec.<br />

ships with instrument<br />

Quartz Liner (2 mm) for Splitless Operation N6121002 22<br />

Quartz Liner (4 mm) for Split Operation N6121001 34<br />

or Large Volume Splitless Injection<br />

Glass Liner (2 mm) for Splitless Operation N6101372 31<br />

Glass Liner (4 mm) for Split Operation N6101052 29<br />

Deactivated Liner for Splitless Operation N6121021 109<br />

2 mm, packed with wool. (pkg. 5)<br />

Deactivated Liner for Split Operation N6121020 236<br />

4 mm, packed with wool. (pkg. 5)<br />

Deactivated Uniliner N6121022 331<br />

4 mm, packed with wool. (pkg. 5)<br />

Injector Body N6100047 306<br />

1/8 in. Swagelok TM Nut Brass (pkg. 5) N9300056 9<br />

Restrictor N6101034 55<br />

1/8 in. Graphite/Vespel Ferrule (pkg. 10) 09920301 84<br />

1/4 in. Graphite Ferrule (pkg. 10) 09920140 43<br />

1/4 in. Swagelok Nut, Stainless Steel (pkg. 5) N9300055 30<br />

Injector Adapter N6100157 105<br />

Charcoal Trap N6100275 242<br />

Charcoal Trap for PPC Version** N6100331 553<br />

Split Vent Tube N6100159 42<br />

Column Nut 1/16 in. Long length 09903392 27<br />

for reversed ferrule (pkg. 5)<br />

* For more septa, see page 159.<br />

** Not shown.<br />

Miscellaneous Accessories<br />

Description Part No. Each (€)<br />

2 oz. Replacement Charcoal (30/60 mesh) 03300904 20<br />

5 g. Quartz Wool (Untreated) N6102354 26<br />

Column Ferrule Graphite/Vespel 09920105 84<br />

Liner Removal Tool N6100102 125<br />

Merlin Microseal Adapter Kit N9303344 434<br />

Includes: 2 Merlin Microseal septa,<br />

1 nut, and 1 injection port adapter<br />

Merlin Microseal Septa N9303345 181<br />

Zero Dilution Liner (Inner) N1011446 41<br />

Zero Dilution Liner (Outer) N1011445 74<br />

150


Injectors<br />

Capillary Injectors<br />

Split/Splitless Injector Add-On Kits<br />

Capillary Injector with PPC<br />

Kit includes split/splitless injector with programmable<br />

pneumatic control for carrier gas, split vent, heater, sensor,<br />

and heater block. The AutoSystem XL must be PPC ready.<br />

If not, a PPC upgrade kit (N6120146) is required. (See page<br />

166 for more information.) Installation by PerkinElmer<br />

Service is required, but not included.<br />

Voltage Part No. Each (€)<br />

120 V N6120138<br />

240 V N6120139 3128<br />

Complete Capillary Injector Add-On Kits<br />

Kit includes split/splitless injector in module with heater<br />

and sensor, 0-60 psig pressure regulator, and transducer for<br />

pressure readout. For manual gas control.<br />

Voltage Part No. Each (€)<br />

120 V AutoSystem N6120009<br />

240 V AutoSystem N6120022 3329<br />

120 V Clarus N6520012<br />

230 V Clarus N6520013 1916<br />

Dual Capillary Column Adapter Kit<br />

Kit includes all necessary hardware to install two capillary<br />

columns to a capillary injector. Note: Kit does not include<br />

appropriate 1/8 in. 2-hole ferrule. (See page 94) For manual<br />

gas control.<br />

Voltage Part No. Each (€)<br />

120 V N6120050 122<br />

Split/Splitless Injector Starter Kit<br />

for Manual Gas Control<br />

Includes: 2 mm i.d. quartz liner, 4 mm i.d. quartz liner,<br />

silicone O-Rings (10), Thermogreen septa (50), 0.5 mm<br />

graphite ferrules (10), 0.8 mm graphite ferrules (10), 1/16 in.<br />

stainless steel nuts (5), untreated quartz wool, packing rod,<br />

and wafer scribes (10).<br />

Part No. Each (€)<br />

N6120101 574<br />

Injectors Gas Chromatography<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

151


Injectors<br />

Packed Column Injector<br />

Add-On Kits<br />

Injector Replacement Parts<br />

Gas Chromatography Injectors<br />

Packed Column Injector Kit with Manual Pneumatics<br />

Includes: complete injector assembly with heater and sensor,<br />

0-100 mL flow controller, and column head pressure gauge<br />

for installation into the AutoSystem.<br />

Voltage Part No. Each (€)<br />

120 V* N6120007<br />

240 V* N6120023 2245<br />

Packed Column Injector Kit with PPC<br />

The kit includes complete injector assembly with<br />

programmable pneumatic control, heater, sensor, and<br />

heater block. The GC must be PPC ready. If not, a PPC<br />

upgrade kit (N6120146) is required. (See page 166 for<br />

more information.)<br />

Voltage Part No. Each (€)<br />

120 V* N6120136<br />

240 V* N6120137 2288<br />

Packed Column Injector Kit<br />

with Screen Readout and Manual Pneumatics<br />

Includes: complete injector assembly with heater and sensor,<br />

0-100 mL flow controller and column head pressure gauge,<br />

and transducer for screen readout of column carrier flow.<br />

Voltage Part No. Each (€)<br />

120 V* AutoSystem N6120008<br />

240 V* AutoSystem N6120025 2729<br />

120 V* Clarus N6520010<br />

230 V* Clarus N6520011 1398<br />

Packed Column Injector Kit AutoSystem XL and Clarus<br />

The kit includes complete injector, heater, sensor,<br />

and heater block. (Does not include pneumatics.)<br />

Voltage Part No. Each (€)<br />

120 V* N6120071<br />

240 V* N6120072 1824<br />

Packed Column Injector Starter Kit<br />

Includes glass liner, needle guide,<br />

Thermogreen septa (50), untreated<br />

quartz wool, and packing rod.<br />

Packed On-Column Injector for 1/4 in.<br />

(Long-Legged) Glass Columns<br />

Part No.<br />

Each (€)<br />

N6120100 389<br />

For use with 1/4 in. (long-legged) on-column glass column.<br />

Includes: complete injector, heater, and sensor and heater<br />

block. Does NOT include pneumatics.<br />

Voltage Part No. Each (€)<br />

120 V* N6520016<br />

240 V* N6520017 1970<br />

* Service installation required.<br />

1<br />

2<br />

3<br />

4<br />

5<br />

Description Part No. Each (€)<br />

Septum Cap N6100153 96<br />

Septa Thermogreen (pkg. 50)** N6621028 202<br />

Needle Guide N6101050 48<br />

Glass Liner N6101048 57<br />

Quartz Liner N6121000 124<br />

Packed Injector Assembly N6100048 536<br />

** For more septa see page 159.<br />

1<br />

2<br />

3<br />

4<br />

5<br />

152


Injectors<br />

Packed Column Injector<br />

Miscellaneous Accessories<br />

Injector/Detector Adapter 1/4 in.<br />

Adapter fits on injector and detector<br />

outlet (inside oven) for use with<br />

1/4 in. columns.<br />

Liner Removal Tool<br />

Allows easy removal of glass<br />

liners from injector port.<br />

Part No. Each (€)<br />

00080100 172<br />

Part No. Each (€)<br />

N6100102 125<br />

Quartz Wool<br />

Quartz wool (untreated) for<br />

packing glass liners. (5 g.)<br />

Silanized Glass Wool<br />

Packing for wide-bore glass liners.<br />

(2 oz.)<br />

Wide-Bore Adapter Kit<br />

0.53 Capillary Column Adapter Kit<br />

Part No.<br />

Each (€)<br />

N6102354 26<br />

Part No.<br />

Each (€)<br />

03300905 34<br />

Silanized Glass Wool<br />

Part No. 03300905<br />

The AutoSystem Wide-Bore Adapter Kit allows conversion<br />

of the packed inlet for 0.53 mm capillary column operation.<br />

The kit includes 0-20 mL flow control element, wide-bore<br />

adapter with 1/16 in. fitting, wide-bore glass liner, and<br />

column support hanger. Can be used in both on-column<br />

and off-column modes of operation.<br />

Part No. Each (€)<br />

N6120001 523<br />

Injectors Gas Chromatography<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

153


Injectors<br />

POC Injector<br />

POC Replacement Parts<br />

1<br />

2<br />

3<br />

4<br />

5<br />

Components Part No. Each (€)<br />

Septum Cap N6100153 96<br />

Septa (pkg. 50)** N6621028 202<br />

Needle Guide N6101702 66<br />

Liner/Hour Glass N6101703 37<br />

Body Assembly N6100256 555<br />

** For more septa see page 159.<br />

Programmed-Temperature<br />

On-Column Injector System<br />

The Programmed-Temperature On-Column (POC) Inlet is<br />

designed to be used with fused-silica capillary columns.<br />

The sample is injected onto the column while the inlet is<br />

cool.After the injection, the inlet begins to heat. This delay<br />

in heating avoids the flash vaporization associated with a<br />

normal injection. This explosive vaporization can cause<br />

thermal breakdown and/or discrimination of certain<br />

analytes, which can be avoided by using the POC.<br />

Gas Chromatography Injectors<br />

2<br />

3<br />

4<br />

1<br />

5<br />

The POC Injector is best used to achieve recovery of compounds<br />

of greater than C 60 (e.g., polywaxes). The POC utilizes flow<br />

control, producing the best recovery out to C 100 or greater.<br />

POC Injector with Manual Flow Controller<br />

and Head Pressure Gauge<br />

Kit includes all necessary hardware to install injector into<br />

AutoSystem Series or Clarus Series.<br />

Voltage Part No. Each (€)<br />

120 V* N6120076<br />

240 V* N6120077 2436<br />

POC Injector with Manual Flow Controller and Head<br />

Pressure Gauge with Flow Readout on Screen<br />

Kit includes all necessary hardware to install injector into<br />

AutoSystem Series or Clarus Series.<br />

Voltage Part No. Each (€)<br />

120 V* N6120082<br />

240 V* N6120083 3354<br />

POC Injector with PPC Add-On Kit<br />

Kit includes injector with programmable pneumatic control,<br />

heater, sensor, and heater block. The AutoSystem XL or Clarus<br />

GC must be PPC TM ready. If not, a PPC upgrade kit (N6120146)<br />

is required. (See page 166 for more information.) Installation<br />

by PerkinElmer Service is required, but not included.<br />

Voltage Part No. Each (€)<br />

120 V* N6120142<br />

240 V* N6120143 3219<br />

POC Injector Starter Kit<br />

Includes: needle guides (5), universal connectors (5),<br />

0.53 mm i.d. deactivated fused silica (5 m), 1/16 in.<br />

stainless steel nuts (5), 0.8 mm graphite ferrules (10),<br />

Thermogreen septa (50),<br />

and wafer scribes (10).<br />

Part No. Each (€)<br />

* Service installation suggested. AutoSystem firmware revision 1.7<br />

or higher. Operator’s manual (09938559) revision F or greater.<br />

N6120098 625<br />

154


Injectors<br />

PSS Injector<br />

Programmed-Temperature<br />

Split/Splitless Injector System<br />

PSS Injector Add-On Kits with Manual Pneumatics<br />

The programmed-temperature split/splitless (PSS) inlet<br />

allows accurate sample delivery to a capillary column.<br />

The PSS allows the analysis of thermally labile compounds,<br />

while eliminating the discrimination of high-boiling<br />

compounds. One of the major advantages of the PSS is<br />

that any nonvolatile material will remain in the inlet<br />

liner and not on the front of the column.<br />

PSS with pneumatics and pressure readout on screen. Kit<br />

includes all necessary hardware to install injector into GC.<br />

Voltage Part No. Each (€)<br />

120 V* AutoSystem N6120074<br />

240 V* AutoSystem N6120075 4795<br />

120 V* Clarus N6520014<br />

230 V* Clarus N6520015 2076<br />

PSS Injector with PPC<br />

Kit includes injector with programmable pneumatic control,<br />

heater, sensor, and heater block. The GC must be PPC<br />

ready. If not, a PPC upgrade kit (N6120146) is required.<br />

(See page 166 for more information.)<br />

Voltage Part No. Each (€)<br />

120 V* N6120140<br />

240 V* N6120141 3326<br />

PSS Injector Starter Kit<br />

Includes: universal connectors (5), 0.53 mm i.d. deactivated<br />

fused-silica (5 m), 2 mm i.d. quartz liner, 1 mm i.d. quartz<br />

liner, glass hourglass liner, 1/16 in. stainless steel nuts (5),<br />

0.5 mm i.d. graphite ferrules (10), 0.8 mm i.d. graphite<br />

ferrules (10), Viton ® O-Rings (6), graphite O-Rings (5),<br />

untreated quartz wool, wafer scribes<br />

(10), and Thermogreen septa (50).<br />

Part No. Each (€)<br />

Zero Dilution Liners<br />

Used together as set.<br />

N6120102 956<br />

Description Part No. Each (€)<br />

Inner Liner N1011446 41<br />

Outer Liner N1011447 90<br />

* Service installation suggested.<br />

PSS Replacement Parts<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

9<br />

10<br />

11<br />

12<br />

13<br />

14<br />

13<br />

12<br />

Description Part No. Each (€)<br />

Septum Cap N6100153 96<br />

Injector Cover N6101482 21<br />

Septa** (pkg. 50) N6621028 202<br />

Trap, Charcoal – non PPC version N6100275 242<br />

PPC version (not shown) N6100331 553<br />

Nut N6101715 179<br />

Septum Purge N6100260 548<br />

O-Ring Viton (pkg. 10) max. temp N6101747 11<br />

250 °C, recommended for use with<br />

mass spec. Shipped with instrument.<br />

O-Ring KALREZ ® (pkg. 1) 09921004 33<br />

max. temp. 450 °C<br />

O-Ring Graphite (pkg. 5) N6101751 23<br />

max. temp. 450 °C<br />

Quartz Liner, 2 mm Split Mode N6121004 17<br />

Shipped with instrument.<br />

Quartz Liner, 1 mm Splitless Mode N6121006 108<br />

On-column liner N6101539 47<br />

Body Assembly N6100261 765<br />

Ferrule 1/8 in. x 1/16 in. (pkg. 10) 09920301 84<br />

Nut 1/8 in. 09903128 1<br />

Split Vent Line N6100159 42<br />

Purge Restrictor N6101034 55<br />

Nut 09903392 27<br />

** For more septa see page 159.<br />

11<br />

10<br />

Manual Pneumatic Control (non-PPC)<br />

1 3<br />

2<br />

4<br />

5<br />

6<br />

7<br />

8<br />

9<br />

14<br />

Injectors Gas Chromatography<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

155


Injectors<br />

PreVent<br />

Gas Chromatography Injectors<br />

Enhanced Large Volume Injection<br />

Allows the use of chlorinated solvents with<br />

an electron capture detector.<br />

PreVent Time-Saver Mode<br />

Conventional<br />

C5<br />

100 C4 C6<br />

0<br />

Analyze<br />

Cleanup<br />

Equilibrate<br />

PreVent<br />

100<br />

Analyze<br />

Cleanup<br />

Equilibrate<br />

2 μl of 20 pg/μl Pesticide Solution in n-Hexane<br />

50 μl of 20 pg/μl Solution in Methylene Chloride<br />

0<br />

10 30 50 70<br />

10 30 50 70<br />

Three Successive Injections of Diesel Oil<br />

Normal Injection<br />

Septum changed and liner inspected during run<br />

Normal Injection<br />

PreVent<br />

Isolation Mode<br />

Eliminates downtime during routine injector<br />

maintenance. Can provide approximately 100 extra<br />

analytical hours of productivity per system per year.<br />

ELVI Mode<br />

Facilitates manual injection volumes up to 150 μL<br />

and automatic injection volumes up to 50 μL<br />

without solvent reaching the column or detector.<br />

Time-Saver Mode<br />

Prevents unwanted, high molecular weight material<br />

from reaching the detector. Shortens analysis time,<br />

facilitates isothermal chromatography and protects<br />

the detector from contamination.<br />

ProTect Mode<br />

Eliminates contamination by preventing heavy<br />

components in the sample from reaching the<br />

expensive and retentive chromatographic column.<br />

Allows backflushing during chromatographic run.<br />

PreVent Add-On Kit<br />

Kit includes all necessary hardware to add PreVent capability<br />

to an existing PSS injector with PPC or to a capillary<br />

injector with PPC. Includes restrictor<br />

and mid-point PPC module.<br />

Part No. Each (€)<br />

PreVent Hourglass Guide<br />

PreVent Restrictor<br />

Description Part No. Each (€)<br />

0.06 mm i.d., 108 mm Length N6103080 23<br />

0.06 to 0.25 mm i.d., 104 mm Length N6100342 7<br />

PreVent Spacer<br />

ProTect Add-On Kit<br />

Includes all the necessary parts to add<br />

a ProTect accessory to a Clarus GC.<br />

Includes one ProTect column.<br />

ProTect Replacement Column<br />

MSVent Add-On Kit for the Clarus 500 GC/MS<br />

Includes all the necessary parts to<br />

add an MSVent accessory to a<br />

Clarus GC/MS.*<br />

Part No.<br />

* Requires a PreVent option (N6120144) to be already installed<br />

in the Clarus 500 GC gas chromatograph.<br />

N6120144 2093<br />

Part No.<br />

Each (€)<br />

N6120163 650<br />

Part No.<br />

Each (€)<br />

N6103196 254<br />

Part No.<br />

Each (€)<br />

N6103082 63<br />

Part No.<br />

Each (€)<br />

N6103079 103<br />

Each (€)<br />

N6120179 714<br />

156


Injector Supplies<br />

Injector Liners<br />

Glass Inlet Liners<br />

Inlet liners for split injection have mixing chambers with tortuous flow paths to allow full vaporization of the sample.<br />

Deactivating the surface of these liners prevents active compounds from degrading. Packing the liner with wool will trap<br />

non-volatile residue and prevent column contamination when analyzing dirty samples.<br />

Inlet liners for splitless injection are generally designed as straight tubes, although new designs such as the gooseneck will<br />

help contain the sample in the injector. Packing these liners with wool will also help trap non-volatile residue and prevent<br />

column contamination.<br />

Capillary Split/Splitless Injector Liners<br />

ID OD Length Pk<br />

Description mm mm mm Size Part No. Each (€)<br />

NEW! PSS Splitless Glass Liner Siltek Deactivated Surface Liner (with wool) – 2 4 86.2 5 N6502001 251<br />

General purpose use, ideal for chlorinated pesticides analyses<br />

Split Glass Liner Siltek Deactivated Surface Liner (with wool) – Universal liner for general 4 6.2 92.1 5 N6121020 236<br />

purpose analyses. Surface provides inertness over a wide sample pH range. Wool can<br />

be adsorptive if fibers are broken<br />

NEW! Split Glass Liner (with wool) – 4 6 92.1 5 N6502009 131<br />

Universal liner for general purpose analyses<br />

NEW! Split Siltek Deactivated Glass Liner (with wool) – Universal liner for general purpose 4 6 92.1 5 N6502010 203<br />

analyses. Deactivated surface provides minimal bleed and inertness over a wide<br />

sample pH range<br />

NEW! Clarus Cup Split Glass Liner – Good for both high and low molecular weight 4 6 92.1 5 N6502011 267<br />

compounds. Sample vaporization is aided by tortuous flow path and minimizes<br />

molecular weight discrimination. Difficult to clean<br />

NEW! Clarus Cyclosplitter Glass Liner – Patented cylindrical design for dirty samples, 4 6 92.1 5 N6502012 254<br />

easy to clean and allows many injections before cleaning is required. Not recommended<br />

for large volume injections<br />

Uniliner Deactivated Glass Liner (with wool) – 4 6.2 92.1 5 N6121022 331<br />

Universal liner for general purpose analyses<br />

NEW! Clarus Splitless Glass Liner – Low volume sample analyses, beneficial with 1 6.2 92.1 5 N6502006 164<br />

headspace and purge/trap<br />

Quartz Liner for Splitless Operation (ships with instrument) – 2 6.2 92.1 1 N6121002 22<br />

Standard injector liner<br />

Glass Liner for Splitless Operation – 2 6.2 92.1 1 N6101372 31<br />

Universal liner for general purpose analyses<br />

Deactivated Glass Liner for Splitless Operation (with wool) – 2 6.2 92.1 5 N6121021 109<br />

Good for analyses of trace samples<br />

NEW! Siltek Deactivated Liner (with wool) for Splitless Operation – Optimum sample 2 6.2 92.1 5 N6502004 177<br />

dispertion for active samples. Surface provides inertness over a wide sample pH range.<br />

Wool can be adsorptive if fibers are broken<br />

Quartz Liner for Split Operation – 4 6.2 92.1 1 N6121001 34<br />

Good for large volume injection samples<br />

Glass Liner for Split Operation – 4 6.2 92.1 1 N6101052 29<br />

Universal liner for general purpose analyses<br />

NEW! Siltek Deactivated Double Gooseneck Glass Liner (with wool) – Optimum sample 4 6.2 92.1 5 N6502003 134<br />

dispertion for active samples. Decreases breakdown of active compounds such as<br />

endrin and DDT. Chamber contains sample vaporization cloud. Not suitable for PPC systems<br />

NEW! Cyclo Double Gooseneck Liner for Split Operation – Cylindrical design for large 4 6.2 92.1 5 N6502005 246<br />

volume and trace dirty samples. Decreases injection port discrimination. Cannot be<br />

packed with wool and more difficult to clean<br />

Zero Dilution Glass Outer Liner – Ideal for trace HS work. 2 6.3 90 1 N1011445 74<br />

Use in conjunction with N1011446<br />

Zero Dilution Glass Inner Liner – Ideal for trace HS work. 2 6.3 90 1 N1011446 41<br />

Use in conjunction with N1011445<br />

Column installs at<br />

left side of image.<br />

Injector Supplies Gas Chromatography<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

157


Injector Supplies<br />

Injector Liners<br />

Programmed Temperature Split/Splitless (PSS) Injector Liners<br />

Column installs at<br />

left side of image.<br />

ID OD Length Pk<br />

Description mm mm mm Size Part No. Each (€)<br />

Gas Chromatography Injector Supplies<br />

Packed Column Injector Liners<br />

Column installs at<br />

left side of image.<br />

Quartz Liner for Splitless operation (ships with instrument) – 1 4 86.2 1 N6121006 108<br />

Excellent liner for low volume analyses<br />

NEW! Siltek Deactivated Glass PSS Liner – 1 4 86.2 5 N6502000 343<br />

Used for low volume trace sample analyses<br />

Quartz Liner for Split operation (ships with instrument) – 2 4 86.2 1 N6121004 17<br />

Approved PerkinElmer standard injector liner<br />

NEW! Siltek Deactivated Glass Liner for Split operation 2 4 86.2 5 N6502001 251<br />

(with wool) – Maximum inertness and packed with wool gives<br />

optimum sample dispersion. Surface provides inertness over wide<br />

sample pH range. Wool can be adsorptive if fibers are broken<br />

NEW! Siltek Deactivated Glass Liner for Split operation – Max. 2 4 86.2 5 N6502002 216<br />

inertness gives optimum sample dispersion. Deactivated surface<br />

provides minimal bleed and inertness over a wide sample pH range<br />

Zero Dilution Outer Liner – 2.8 4 83 1 N1011447 90<br />

Use in conjunction with N1011446<br />

Zero Dilution Inner Liner – 2 73 1 N1011446 41<br />

Use in conjunction with N1011447<br />

On-column Glass Liner 2.4 4 86.2 1 N6101539 47<br />

Liner/Hour Glass for POC Injector 2.4 4 19.05 1 N6101703 37<br />

ID OD Length Pk<br />

Description mm mm mm Size Part No. Each (€)<br />

Drilled Uniliner (hole on top) – Excellent liner for high sample 4 6.2 92.1 5 N6121022 331<br />

recovery and linearity, recommended for aqueous injections.<br />

Good for PPC equipped GCs<br />

NEW! Drilled Uniliner (hole on bottom) – Recommended for analysis 4 6.2 92.1 5 N6502013 471<br />

in which compounds of interest could be affected by a tailing<br />

solvent peak. Good for PPC equipped GCs<br />

NEW! Gooseneck Drilled Uniliner (hole on top) – Use for trace, active 4 6.2 92.1 5 N6502014 407<br />

samples, high recovery and linearity<br />

NEW! Gooseneck Drilled Uniliner (hole on bottom) – Use for trace, 4 6.2 92.1 5 N6502015 407<br />

active samples, high recovery and linearity<br />

NEW! Open Top Uniliner (with wool) – Packed with fused silica wool, 4 6.2 92.1 5 N6502016 241<br />

highly recommended for high molecular weight active samples.<br />

The fused silica wool traps dirt and sample residue<br />

NEW! Cyclo Uniliner – Cylindrical design for high molecular weight 4 6.2 92.1 5 N6502017 305<br />

samples provides an excellent vaporization surface. Spiral traps<br />

dirt reducing further residue sample interaction<br />

Wide-Bore Column Glass Liner 6 4 92.1 1 N6101375 29<br />

Wide-Bore Column On/Off Quartz Liner 6 4 92.1 1 N6121003 32<br />

158


Injector Supplies<br />

Injector Septa<br />

Merlin MicroSeal<br />

Merlin MicroSeal Adapter Kit<br />

Increase lifetime with over 2000 injections<br />

2 Step sealing system<br />

Temperature ranges up to 325 °C<br />

Pressure ranges 40 to 100 psi<br />

Low bleed, long life alternative for injector port septa<br />

Quick and easy installation<br />

The Merlin MicroSeal Septa is a unique replacement<br />

septa employing a two-step sealing system and an advanced<br />

elastomer material. Because the syringe needle does not<br />

pierce the septa, there is no debris and ghost peaks are<br />

greatly reduced. The MicroSeal Septa also reduces the<br />

incidence of bent syringe needles and liner contamination.<br />

Usable in either manual or autosampler applications, this<br />

septa can improve your productivity and run reliability.<br />

Designed to be used with 23 gauge straight needle syringes.<br />

Pressure ranges from 4 to 100 psi and injection port<br />

temperatures up to 325 °C. Easy installation on most<br />

PerkinElmer chromatographs.<br />

Merlin MicroSeal Nut<br />

Merlin MicroSeal<br />

Adaptor<br />

High Pressure Merlin MicroSeal Kit:<br />

Includes: 2 Merlin MicroSeal septa,<br />

1 nut, and 1 injection port adapter.<br />

Merlin MicroSeal Septum<br />

Merlin MicroSeal Septa. (pkg 1)<br />

Septa for Use with All Injectors<br />

PTFE-Silicone Injector Septa<br />

Merlin MicroSeal<br />

Septum<br />

Part No.<br />

Maximum recommended operating temperature 300 °C.<br />

11 mm diameter.<br />

Each (€)<br />

N9303344 434<br />

Part No.<br />

Each (€)<br />

N9303345 181<br />

Description Part No. Each (€)<br />

Package of 12 00091357 14<br />

Package of 50 00090652 58<br />

Merlin MicroSeal Septum Cut-Away View<br />

Syringe needle<br />

Syringe needle wiper<br />

O-rings seal needle<br />

during injection<br />

Microseal septum<br />

Duckbill opens easily, seals reliably<br />

BTO TM (Bleed Temperature Optimized) Injector Septa<br />

Maximum recommended operating temperature 300 °C.<br />

Low bleed, high temperature. 11 mm diameter.<br />

Description Part No. Each (€)<br />

Package of 50 N9302972 103<br />

Thermogreen Injector Septa<br />

Maximum recommended operating temperature 350 °C.<br />

Low bleed, high temperature. 11 mm diameter.<br />

Description Part No. Each (€)<br />

Package of 50 N6621028 202<br />

Low Bleed Injector Septa<br />

Maximum recommended operating temperature 320 °C.<br />

11 mm diameter.<br />

Description Part No. Each (€)<br />

Package of 50 N9303343 81<br />

Silicone Injector Septa<br />

Septum nut aligns needle<br />

Septum cup<br />

Spring<br />

Maximum recommended operating temperature 250 °C.<br />

11 mm diameter.<br />

Description Part No. Each (€)<br />

Package of 50 54019985 36<br />

Injector Supplies Gas Chromatography<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

159


Injector Supplies<br />

Subambient Accessories<br />

Gas Chromatography Injector Supplies<br />

PerkinElmer offers subambient systems which are<br />

microprocessor controlled. This control allows precise<br />

injection of coolant for the greatest accuracy. Our design<br />

assures you of minimum thermal gradients, thereby<br />

eliminating the peak splitting often found in<br />

other systems.<br />

NOTE: All of the subambient systems require, but do not include,<br />

PerkinElmer Service installation.<br />

Pressure Ratings<br />

LN 2 20 – 30 psi<br />

CO 2 50 –70 psi<br />

AutoSystem<br />

Subambient Accessories<br />

Liquid Carbon Dioxide (CO 2 ) Subambient Accessory<br />

Contains all of the necessary hardware to add subambient<br />

capability. Capable of operating down to -50 °C. Installation<br />

by PerkinElmer Service is required, but not included.<br />

Part No.<br />

Liquid Nitrogen (LN 2 ) Subambient Accessory<br />

Contains all of the necessary hardware to add subambient<br />

capability. Capable of operating down to -99 °C. Installation<br />

by PerkinElmer Service is required, but not included.<br />

Liquid Nitrogen (LN 2 ) Subambient Accessory<br />

for Temperature Programmable Injectors<br />

Each (€)<br />

N6120017 1977<br />

Part No.<br />

Each (€)<br />

N6120016 1671<br />

Contains all of the necessary hardware to add subambient<br />

capability to two temperature programmable injectors<br />

(PSS/Program Split Splitless, POC/Program On-Column)<br />

on one Gas Chromatograph. Capable of operation down to<br />

-99 °C. Requires but does not include oven LN 2 subambient.<br />

Installation by PerkinElmer Service<br />

is required, but not included.<br />

Part No. Each (€)<br />

N6120078 727<br />

Subambient Accessories<br />

Liquid Carbon Dioxide (CO 2 ) Subambient Accessory<br />

Contains all the necessary hardware to add subambient<br />

capability to AutoSystem XL or Clarus GC. Operating<br />

temperature range down to -50 °C.<br />

Installation by PerkinElmer Service<br />

is required, but not included.<br />

Part No.<br />

N6120159<br />

Each (€)<br />

1231<br />

Liquid Nitrogen (LN 2 ) Subambient Accessory<br />

Contains all the necessary hardware to add subambient<br />

capability to AutoSystem XL or Clarus GC. Operating<br />

temperature range down to -99 °C.<br />

Installation by PerkinElmer Service<br />

is required, but not included.<br />

Part No.<br />

N6120158<br />

Each (€)<br />

1352<br />

160


Injector Supplies<br />

Syringes<br />

Autosampler Syringes<br />

Replacement<br />

Syringe<br />

Needle<br />

Description Volume/o.d. Part No. Each (€) Part No. Each (€)<br />

Low injection volume analysis. 0.5 μL/0.63 N6101252 210 N6101469 74<br />

Plunger type: metal plunger in needle.<br />

Routine analysis. Shipped with instrument. 5 μL/0.63 N6101390 110<br />

Plunger metal plunger in barrel with Teflon ® -tipped seal.<br />

0.53 capillary column on-column injection. 5 μL/0.47 N6101380 113<br />

Plunger type: metal plunger in barrel.<br />

Low injection volume. 0.53 capillary on-column injection. 5 μL/0.47 N6101253 210 N6101470 74<br />

Plunger type: metal plunger in needle.<br />

Routine analysis, plunger type: metal plunger in barrel. 5 μL/0.63 N6101251 110<br />

Metal plunger in barrel type 50 μL/0.47 N9302799 223<br />

50 μL/0.63 N6101760 200<br />

Needle Syringes<br />

Why a 7 cm Needle?<br />

All PerkinElmer injectors have been tested and optimized<br />

for use with a 7 cm needle. A 7 cm needle is critical to be<br />

sure your sample is deposited in the optimal zone.<br />

Point Style 2<br />

General-purpose point style designed for septum penetration<br />

in all chromatographic techniques. The needle has a 22°<br />

bevel with the tip slightly bent to minimize coring and<br />

needle plugging.<br />

Point Style 3<br />

Needle has a 90° bevel. Point style 3 is recommended<br />

when the syringe is used for accurate pipetting of liquids.<br />

Excellent for mixing standards of very small volume.<br />

Fixed Needle Syringes<br />

Syringe P.S. #2 P.S. #3<br />

Capacity Part No. Each (€) Part No. Each (€)<br />

10 μL 00230113 47<br />

10 μL* 00230523 47<br />

25 μL N9302202 52 09904823 52<br />

50 μL N9302203 61 09904941 60<br />

100 μL N9302204 61 09904822 62<br />

Fixed Needle Syringe Six Pack<br />

Contains six syringes (10 μL, fixed<br />

needle, point style #2, 00230523).<br />

Fitted with 7 cm needle.<br />

Removable Needle Syringes (RN)<br />

Part No.<br />

Each (€)<br />

N9302230 236<br />

Syringe P.S. #2<br />

Capacity Part No. Each (€)<br />

10 μL* N9302210 71<br />

25 μL N9302211 78<br />

50 μL N9302212 83<br />

100 μL N9302213 94<br />

250 μL N9302214 110<br />

500 μL N9302215 123<br />

* Standard syringe but fitted with 7 cm needle for PerkinElmer injectors.<br />

Injector Supplies Gas Chromatography<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

161


Injector Supplies<br />

Syringes<br />

Gas Chromatography Injector Supplies<br />

Replacement Needles<br />

for Removable Needle Syringes (RN)<br />

Syringe P.S. #2<br />

Capacity Gauge Length Qty. Part No. Each (€)<br />

10 μL** 26S 7 cm pkg. 3 N9302220 35<br />

10 μL 26S 2 in. pkg. 3 N9302222 35<br />

25 μL 22S 2 in. pkg. 3 N9302224 35<br />

50 μL 22S 2 in. pkg. 3 N9302224 35<br />

100 μL 22S 2 in. pkg. 3 N9302226 35<br />

Replacement Needles for RN Syringes<br />

Needle Gauge Volume Part No. Each (€)<br />

26S 10 μL N9302222 35<br />

22S 25, 50, 100 μL N9302224 35<br />

22S 250 μL N9302226 35<br />

P.S. = Point Style<br />

** Recommended for PerkinElmer injectors.<br />

Syringes – Gas Tight<br />

Fixed<br />

Removable<br />

Syringe Needle (N) Needle (RN)<br />

Capacity Part No. Each (€) Part No. Each (€)<br />

10 μL N9302240 61 N9302241 83<br />

25 μL N9302242 59 N9302243 75<br />

50 μL N9302244 71 N9302245 94<br />

100 μL N9302247 75<br />

250 μL N9302250 78 N9302251 94<br />

500 μL N9302253 78 N9302254 94<br />

1.0 mL N9302256 99 N9302257 111<br />

2.5 mL N9302259 75<br />

5.0 mL N9302262 94<br />

10 mL N9302265 120 N9302266 140<br />

10 mL Gas Tight Syringe Part No. N9302266<br />

Ultramicro Volume Syringes<br />

Recommended for liquid sample injections of less than<br />

5 μL for gas chromatography. Syringes come standard with<br />

needle length of 7 cm – optimum for PerkinElmer injectors.<br />

Syringe Needle Syringe<br />

Capacity Gauge Part No. Each (€)<br />

0.5 μL 25 N9302231 134<br />

1.0 μL 26* 00230111 106<br />

1.0 μL 22 00230177 106<br />

2.0 μL 25 N9302235 123<br />

2.0 μL 23 N9302237 143<br />

5.0 μL 24 00230178 123<br />

* Recommended for PerkinElmer Wide-Bore Capillary Adapter.<br />

162


Laboratory Supplies<br />

Gas Sampling Supplies<br />

Filters and Traps<br />

Carrier Gas Filter for GC/MS<br />

21 in. long with 1/8 in. fitting.<br />

Gas In-line Filter<br />

This in-line filter<br />

removes moisture,<br />

oil, and particulate<br />

from gas <strong>supplies</strong>. Large capacity filter requires fewer filter<br />

changes, and improves baseline stability and chromatographic<br />

results. Free-standing model also available. Maximum<br />

pressure 100 psig. Trap packing can be refilled. Approximate<br />

dimensions: 2 1/4 x 17 in. with 1/8 in. fittings.<br />

Description Part No. Each (€)<br />

Base-Mount Filter N9301177 299<br />

In-line Gas Filter N9301178 200<br />

Packing Refill Kit (sufficient for two refills) N9301176 29<br />

Hydrocarbon Trap<br />

Use our activated charcoal<br />

in-line trap to remove<br />

gaseous hydrocarbons<br />

from carrier gas supply.<br />

This trap will remove all hydrocarbons at room temperature<br />

except methane. <strong>Essential</strong> for purge- and-trap systems, or<br />

high-sensitivity FID operation when contamination is a<br />

problem. Maximum pressure 1000 psig. Frits at the end<br />

prevent any particles from entering the gas stream. Trap is<br />

purged with nitrogen and should be purged with the gas you<br />

plan to use. Approximate dimensions:<br />

2 x 14 in. with 1/8 in. fittings.<br />

Part No. Each (€)<br />

Indicating Oxygen Trap<br />

Indicating trap has a<br />

capacity of 40 cc of<br />

pure oxygen. The trap<br />

has a maximum pressure of 100 psig. The trap is shipped in<br />

the active state purged with hydrogen. It is recommended<br />

that you purge the trap with the gas you will be using.<br />

Approximate dimensions: 1 3/8 x 10 1/4 in. Includes<br />

1/8 in. fittings. It is recommended that<br />

the indicating trap be used downstream Part No. Each (€)<br />

of the high-capacity oxygen trap.<br />

N9301191 159<br />

Gas Flow<br />

High-Capacity<br />

Oxygen Filter<br />

Indicating Oxygen Filter<br />

Indicating<br />

Packing<br />

Part No.<br />

Each (€)<br />

N6471025 293<br />

N9301192 147<br />

Gas Flow<br />

Oxygen Trap<br />

High efficiency oxygen<br />

trap has a capacity of 2.5<br />

liters at room temperature.<br />

It is also effective for removing sulfur compounds such as<br />

hydrogen sulfide and mercaptans. This oxygen trap is for use<br />

with nonoxidizing gases such as; He, Ar, N 2 , and CH 4 . Oxygen<br />

removal to below 70 ppb using normal GC flow rates. The<br />

catalyst is a copper-based material that forms copper oxide<br />

in the presence of oxygen; no gas is produced from this<br />

reaction. This trap is intended for use with gases containing<br />

less than 1% oxygen. The trap is delivered active purged<br />

with nitrogen. (Purging with the gas you will be using is<br />

recommended.) Maximum pressure 1000 psig. Approximate<br />

dimensions: 2 x 14 in. including<br />

fitting end; fittings are 1/8 in.<br />

Part No. Each (€)<br />

Safe Glass Moisture Trap<br />

N9301179 262<br />

In-line moisture trap.<br />

Drierite indicating agent<br />

and Molecular Sieve 5A<br />

are packed in glass which is enclosed in a safety plastic tube<br />

in the event the glass breaks. Unique loading design allows<br />

operation in any orientation without channeling. For use with<br />

pressures up to 100 psig. Designed for use with GC detectors<br />

that require high-purity gases. Recommended for ELCD and<br />

ECD systems in which moisture and contamination are a<br />

problem. Trap is shipped active and purged with nitrogen.<br />

It is recommended that you purge the trap with the gas you<br />

plan to use. Approximate dimensions:<br />

1 3/8 x 10 1/4 in. with 1/8 in. end fittings. Part No. Each (€)<br />

Recommended Filters<br />

N9301193 159<br />

Detector Carrier Gas H 2 Air<br />

ECD Moisture Trap<br />

and Oxygen Trap<br />

ELCD Hydrocarbon Trap* Hydrocarbon Trap<br />

FID Hydrocarbon Trap* Moisture Trap Moisture Trap<br />

FPD Hydrocarbon Trap* Moisture Trap Moisture Trap<br />

MS Indicating Oxygen Trap<br />

NPD Hydrocarbon Trap* Moisture Trap Moisture Trap<br />

PID Hydrocarbon Trap*<br />

TCD Hydrocarbon Trap*<br />

* Oxygen Trap if capillary columns are used.<br />

Note: All gases MUST have a minimum purity of 99.995%.<br />

Gases for either ELCD or mass spectrometer MUST have a<br />

minimum purity of 99.999%.<br />

Laboratory Supplies Gas Chromatography<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

163


Laboratory Supplies<br />

Gas Sampling Supplies<br />

Gas Purification Systems<br />

Gas Chromatography Laboratory Supplies<br />

All-In-One Gas Purification System<br />

The trace contaminant removal available from the<br />

three-cartridge Gas Purification System is now available<br />

in a single-cartridge system. The purifier consists of a<br />

manifold head and an all-welded steel cartridge with a<br />

multiple-layer adsorbent bed to sequentially remove<br />

water, oxygen, sulfur compounds, and hydrocarbons.<br />

The All-In-One Gas Purification System has a capacity for<br />

oxygen of at least 450 cc, enough to purify eight 292 cu. ft.<br />

tanks of 99.995% pure helium. Water capacity is at least<br />

1.7 g, while capacity for hydrocarbons (as n-butane) is<br />

5.2 g. The system comes ready to wall mount, but may be<br />

bench-mounted by removing from the bracket and attaching<br />

to a bench-mount base (included). It is shipped fully<br />

activated and filled with high-purity helium.<br />

Product Part No. Each (€)<br />

Gas Purification System with Trap, 1.8 in. Fittings N9306050 345<br />

Replacement Cartridge N9306051 206<br />

Gas Supply Installation Kit<br />

Including hardware to hook up three gas <strong>supplies</strong> to gas<br />

chromatograph. Kit includes: (1) safety gas flow restrictor<br />

for hydrogen (00090038), (1) restrictor warning tag<br />

(00091216), (1) restrictor tag (00091360), (50 ft.) 1/8 in.<br />

refrigeration grade copper tubing (N9300077), (6) 1/8 in.<br />

Swagelok nut (09903128), (6) 1/8 in. brass front ferrules<br />

(09903129), (6) 1/8 in. brass rear ferrules (09903130),<br />

(3) 1/8 in. Swagelok brass 3-way tee (09903170), (3) 1/4 in.<br />

NPT x 1/8 in. Swagelok adapter (09903795), and (1) 1/4 in.<br />

NPT x 1/8 in. NPT reducer female (09903212).<br />

Part No.<br />

Each (€)<br />

N6500123 211<br />

Three-Cartridge Gas Purification System<br />

This system will provide in-line contaminant removal for<br />

your GC gases. This system has convenient replaceable<br />

cartridges with a visual indicator. The PerkinElmer Gas<br />

system consists of three cartridges in series to reduce<br />

column damaging impurities. The first cartridge in the<br />

system will remove residual hydrocarbons and water from<br />

the carrier gas stream. The second cartridge provides<br />

high-capacity oxygen removal (capacity is at least 1000 cc<br />

of pure oxygen); the third cartridge contains an inorganic<br />

indicator that changes from light green to gray to provide<br />

warning when the high-capacity oxygen trap is depleted.<br />

All systems are helium leak tested after assembly.<br />

Approximate dimensions: 33 cm W x 33 cm H x 8 cm D;<br />

weight 4 kg.<br />

Cartridges are easy to replace<br />

High capacity<br />

Wall bracket gets the system up and out of the way<br />

Product Part No. Each (€)<br />

Gas Purification System, 1/8 in. fittings N9306002 689<br />

complete system (includes all three traps)<br />

Hydrocarbon Moisture Replacement Cartridge N9306003 185<br />

High Capacity Oxygen Replacement Cartridge N9306004 204<br />

Indicating Oxygen Replacement Cartridge N9306005 182<br />

Replacement Cartridge Set, one each N9306048 573<br />

hydrocarbon/moisture, high-capacity oxygen<br />

and indicating oxygen<br />

Bypass Accessory, allows operation of system N9306006 75<br />

when installed in place of cartridge<br />

Bench Mount Adapter N9306014 48<br />

164


Laboratory Supplies<br />

Gas Sampling Supplies<br />

High Purity Brass Regulators<br />

PerkinElmer regulators are constructed of high-purity<br />

brass barstock and have stainless steel diaphragms and<br />

metal-to-metal seals. They are suitable for use with<br />

high-purity (>99.995% pure) non-corrosive gases.<br />

Regulators terminate in a 1/4 in. NPT Swagelok fitting.<br />

Barstock body construction<br />

Stainless steel diaphragms<br />

Metal-to-metal seals<br />

Use with high-purity carrier gas<br />

High-purity Brass Regulators (Dual Stage)<br />

Delivery Cylinder<br />

CGA Delivery Pressure Pressure Gauge<br />

Fitting Pressure Use Range (psig) Gauge (psig) (psig) Part No. Each (€)<br />

CGA-350 H 2 and Ar/CH 4 mixes 4-100 0-250 0-3000 09907128 763<br />

CGA-580 He, Ar 4-100 0-250 0-3000 09907127 763<br />

High-purity Brass Regulators (Single Stage)<br />

Delivery Cylinder<br />

CGA Delivery Pressure Pressure Gauge<br />

Fitting Pressure Use Range (psig) Gauge (psig) (psig) Part No. Each (€)<br />

CGA-350 H 2 and Ar/CH 4 mixes 3-80 0-100 0-3000 00230091 381<br />

CGA-580 He, Ar 10-180 0-250 0-3000 00230253 381<br />

CGA-590* Air 5-180 0-250 0-3000 00230090 381<br />

* Supplied with 590-580 Adapter.<br />

PG-H 2 Pure Gas Hydrogen Generators<br />

The PG-H 2 series Hydrogen Generators employ the newest<br />

membrane technology available for the safe production<br />

of pure hydrogen gas.<br />

The patented DBS PG-H 2 series of Hydrogen Pure Gas<br />

Generators is ideal for operation with gas analyzers, as fuel<br />

gas for flame tools, or as a source of pure hydrogen. Electrolytic<br />

membrane technology is preferred over alternative hydrogen<br />

generating techniques because it is clean, requires less<br />

maintenance, and there is no need to store chemicals<br />

to maintain operation. Only pure water, either distilled<br />

or deionized, is required to provide trouble-free,<br />

long-term operation.<br />

Features and Benefits:<br />

LCD display shows set points, operating conditions and status<br />

Continuous or intermittent operation<br />

Visual operating status lights<br />

Alarm conditions<br />

Flow indicator informs the operator at a glance that hydrogen<br />

gas is flowing at the specified rate<br />

Bi-directional RS232 interface<br />

Selectable auto start<br />

Remote control (optional)<br />

Cascading of 2 or more units (optional)<br />

PC-Control capability<br />

PG-H2 Series<br />

Hydrogen Generator<br />

High-Purity Brass Regulator Part No. 09907128<br />

Safety Straps<br />

Nylon adjustable cylinder safety<br />

straps hold tanks securely to<br />

bench top or wall.<br />

Model/Component Part No. Each (€)<br />

Wall Mount N9301298 101<br />

Bench Mount N9301299 101<br />

Model/Component Part No. Each (€)<br />

Deionizer Bag N9306066 75<br />

Desiccant Cartridge, Fitting, and Refill Kit N9306064 279<br />

Desiccant Refill (pkg. 3) N9306065 101<br />

PG-H2 100 Hydrogen Generator 100 mL/min. N9306058 4322<br />

PG-H2 160 Hydrogen Generator 160 mL/min. N9306059 5200<br />

PG-H2 250 Hydrogen Generator 250 mL/min. N9306060 6000<br />

PG-H2 500 Hydrogen Generator 500 mL/min. N9306061 8000<br />

Laboratory Supplies Gas Chromatography<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

165


Laboratory Supplies<br />

Instrument Pneumatics Accessories<br />

Gas Chromatography Laboratory Supplies<br />

Manual Pneumatics<br />

0-20 mL/min. Flow Accessory<br />

For use when converting a flow<br />

controller for low flow applications.<br />

Auxiliary Gas Pneumatics Box<br />

For use with carrier or combustion gas. 0-100 psig gauge.<br />

This compact unit comes in either wall or bench mount,<br />

with or without toggle valve for quick shutoff. Design<br />

allows several units to be installed together. 1/8 in.<br />

Swagelok fittings for gas inlet/outlet. Mounting screws<br />

included. Dimensions: 15 x 2 x 7 in. (D x W x H).<br />

Description Part No. Each (€)<br />

With Toggle Valve N9302146 784<br />

Without Toggle Valve N9302145 746<br />

Flow Controller and Gauge with Screen Readout<br />

Includes: flow controller, gauge, and<br />

transducer for mounting into an<br />

empty instrument pneumatic panel.<br />

Part No.<br />

PPC Detector Control Pneumatics Add-On Kit<br />

Kit includes parts to add one channel of PPC control for<br />

detector gas to an existing detector. For use with hydrogen<br />

or air on FID, NPD, and FPD; makeup on ECD and PID. The<br />

GC must be PPC ready. If not, a PPC upgrade kit (N6120146)<br />

is required. Requires, but does not include, appropriate<br />

PPC frit (see table).<br />

Note: Do not use for ELCD or TCD makeup. These require special kits with<br />

tees. The AutoSystem XL must be PPC ready. If not, a PPC upgrade kit<br />

(N6120146) is required. Installation by PerkinElmer Service is required,<br />

but not included.<br />

Part No. Each (€)<br />

PPC Flow Control Pneumatics Add-On Kit<br />

for Packed or POC Injector<br />

Each (€)<br />

N6101377 261<br />

Part No.<br />

Each (€)<br />

N6120004 670<br />

N6120148 1192<br />

Kit includes parts to add PPC flow control for carrier gas<br />

to an existing packed or POC injector. Requires but does<br />

not include appropriate PPC frit (see table). The GC must<br />

be PPC ready. If not, a PPC upgrade kit (N6120146) is<br />

required. Installation by PerkinElmer Service is required,<br />

but not included.<br />

Part No. Each (€)<br />

N6120149 2130<br />

PPC Upgrade Kit<br />

Kit includes the main control board and hardware to add<br />

PPC capability to an existing AutoSystem XL or Clarus Gas<br />

Chromatograph. Installation by PerkinElmer Service is<br />

required, but not included.<br />

Part No. Each (€)<br />

Preset Pressure Regulator<br />

Consists of a preset (30 psig) nonadjustable pressure regulator<br />

for use with manual detector gas controls. Recommended for<br />

use on hydrogen and air for FID.<br />

Part No. Each (€)<br />

Pressure Regulator with Screen Readout<br />

Includes pressure regulator (0-60 psig)<br />

and transducer for mounting into an<br />

empty instrument panel.<br />

PPC Frits<br />

N6120146 1354<br />

N6101473 249<br />

Part No.<br />

Each (€)<br />

N6120005 434<br />

Injector/<br />

Detector Gas Frit No. Color Part No. Each (€)<br />

ECD Argon/ 4 Black N6120155 84<br />

Methane<br />

or Nitrogen<br />

FID Air 6 Blue N6120157 84<br />

FID Hydrogen 4 Black N6120155 84<br />

FPD Air 5 Green N6120156 84<br />

FPD Hydrogen 4 Black N6120155 84<br />

NPD Air 5 Green N6120156 84<br />

NPD Hydrogen 1 Silver N6120152 84<br />

Packed Carrier 4 Black N6120155 84<br />

POC Carrier 3 Yellow N6120154 84<br />

POC Carrier Use 2 Red N6120153 84<br />

for Low Flows<br />

(i.e.,


Laboratory Supplies<br />

Maintenance Supplies<br />

Flow Meters<br />

Tools<br />

Digital Flow Meter<br />

The PerkinElmer Model 570 meets ISO 9000 and Good<br />

Laboratory Practice (GLP) requirements. The flow meter<br />

comes with a “Certificate of Calibration” that states all of<br />

the traceability information needed for ISO-9000<br />

compliance. The Model 570 is uniquely indentified by<br />

serial number, internal instrument number, and date(s) of<br />

calibration. It is also capable of periodic recalibration.<br />

Product Part No. Each (€)<br />

Digital Flow Meter N9302974 1016<br />

Replacement Glass for Digital Flow Meter N9303429 80<br />

PerkinElmer Electronic Flowmeter 1000<br />

Flow range 0.1-1000 mL/min.<br />

Operating Temperature 0 to 45 °C<br />

Traceable to NIST Primary Standard<br />

Split Ratio Mode<br />

Accuracy +/- -3%<br />

LCD Alphanumeric Display<br />

The PerkinElmer Flowmeter 1000 allows for rapid real-time<br />

flow measurements. Flow rates measured in mL/min.<br />

(volumetric flow). The PerkinElmer Flowmeter 1000 can<br />

quickly calculate split ratios. Ratios are displayed in real<br />

time. Flowmeter not compatible with corrosive or<br />

flammable gases. Portable operation.<br />

(9 V battery included).<br />

Part No. Each (€)<br />

Soap Bubble Flow Meters<br />

N9307029 842<br />

The glass soap bubble flow meters are calibrated in 1 and<br />

10 mL two-stage or 1, 10, and 100 mL three-stage for easy<br />

flow reading. Bubble meters come complete with liquid<br />

soap, rubber squeeze bulb, miscellaneous-sized plastic tube<br />

pieces to adapt to various fittings, and instructions (stand<br />

required, but not included – N9303314).<br />

Product Part No. Each (€)<br />

Two-stage 00230522 101<br />

Three-stage N9300081 218<br />

Stand N9303314 74<br />

Adjustable Wrench<br />

Adjustable 12 in. steel wrench for cylinder pressure<br />

regulators. Wrench opens out to 1 3/4 in.<br />

Fits all regulators listed in this catalog. Part No. Each (€)<br />

Basic Tool Kit<br />

Tools come in tool box for easy storage and use. Kit includes:<br />

open-end wrench set (6 pc.), screwdriver set (6 pc.), adjustable<br />

wrench (6 in.), chain nose pliers (narrow), wire cutters, and<br />

wire strippers.<br />

Part No. Each (€)<br />

Deluxe Tool Kit<br />

Great for use on all lab<br />

instruments! Kit includes<br />

the following tools: openend<br />

wrench set (6 pc.),<br />

screwdriver set (6 pc.),<br />

adjustable wrench (6 in.),<br />

chain nose pliers (narrow),<br />

wire cutters, wire strippers,<br />

slip-joint pliers (6 in.), long<br />

nose No. 5 stainless steel<br />

tweezers (4 3/8 in.), needle file set (6 pc.), Allen key set<br />

(11 pc. imperial sizes), and Allen key set (9 pc. metric sizes).<br />

Shipped in a plastic tool box for<br />

convenient storage.<br />

Part No. Each (€)<br />

6-Piece, Open-End Wrench Set<br />

Six sizes. Includes:<br />

1/4 x 5/16 in. 5/16 x 3/8 in.<br />

3/8 x 1/16 in. 7/16 x 1/2 in.<br />

1/2 x 9/16 in. 9/16 x 5/8 in.<br />

Tubing<br />

N9301324 55<br />

N9301327 242<br />

N9301328 306<br />

Part No.<br />

Each (€)<br />

N9301325 69<br />

Description Qty. Part No. Each (€)<br />

Precleaned Copper Tubing 50 ft. N9300077 120<br />

Teflon ® Tubing, 1/8 in. o.d. 1 ft. 02506483 3<br />

Teflon Tubing, 1/16 in. o.d. Hall Solvent Lines 1 ft. 09985708 7<br />

Tygon Tubing, 1/4 in. i.d., 3/8 in. o.d. for 1 ft. 02506518 3<br />

Water and Air (not for carrier gas)<br />

Laboratory Supplies Gas Chromatography<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

167


Laboratory Supplies<br />

Valves<br />

Valves<br />

Gas Chromatography Laboratory Supplies<br />

There are two types of valves offered. Internal Volume<br />

sample size is determined by an etched rotor inside the<br />

valve. External Volume sample size is determined by a<br />

sample loop outside the valve. External valves are used<br />

primarily for sample injection and/or switching applications.<br />

A valve used for just switching requires another valve<br />

for sample injection. Valves include nuts and ferrules,<br />

but not loops.<br />

3-Port Valve<br />

Requires 90° actuator and standoff for automatic operation.<br />

Replacement<br />

Max. Max. Valve Rotor<br />

Rotation Temp. Pressure Fitting (in.) Coating Part No. Each (€)<br />

Part No. Each (€)<br />

90° 330 °C 300 psi 1/16 N9302885 548<br />

4-Port Valve<br />

Requires 60° actuator and standoff for automatic operation.<br />

90° 175 °C 400 psi 1/16 N9302809 721<br />

90° 350 °C 300 psi 1/16 N9302813 740<br />

90° 330 °C 300 psi 1/8 N9302817 568<br />

6-Port Valve<br />

Requires 60° actuator and standoff for automatic operation.<br />

60° 175 °C 400 psi 1/16 N9302810 810 N9302897 107<br />

60° 350 °C 300 psi 1/16 N9302814 823 N9302901 107<br />

60° 330 °C 300 psi 1/8 N9302818 644 N9302905 107<br />

8-Port Valve<br />

Requires 45° actuator and standoff for automatic operation.<br />

45° 175 °C 400 psi 1/16 N9302811 899<br />

45° 350 °C 300 psi 1/16 N9302815 905<br />

45° 330 °C 300 psi 1/8 N9302819 740<br />

10-Port Valve<br />

Requires 36° actuator and standoff for automatic operation.<br />

36° 175 °C 400 psi 1/16 N9302812 899 N9302899 107<br />

36° 350 °C 300 psi 1/16 N9302816 905 N9302903 107<br />

36° 330 °C 300 psi 1/8 N9302820* 765<br />

* Special 4 1/8 in. standoff included.<br />

8-Port Valve<br />

Part No. N9302819<br />

168


Laboratory Supplies<br />

Valves/Loops<br />

4-Port Internal Valve and Rotor for Liquid Sample Injection<br />

Replacement<br />

Valve<br />

Rotor<br />

Fixed Volume (μL) Fitting Size Port Diameter Part No. Each (€) Part No. Each (€)<br />

0.06 1/16 in. 0.016 N9302800 810<br />

0.2 1/16 in. 0.016 N9302802 810 N9302889 107<br />

0.5 1/16 in. 0.016 N9302803 810 N9302890 107<br />

2.0 1/8 in. 0.030 N9302808 810<br />

Max. Temp. = 75 °C, Max. Pressure = 500 psi, Fitting Size = 1/16 in.<br />

These valves require a 90° actuator and standoff for automatic operation.<br />

Sample Loops<br />

4-Port Internal Valve and Rotor<br />

Sample Loops<br />

6-Port 8-Port 10-Port<br />

Volume Size Part No. Each (€) Part No. Each (€) Part No. Each (€)<br />

100 μL 1/16 in. N9302851 29 N9302854 29 N9302857 29<br />

100 μL 1/8 in. N9302860 29 N9302866 29<br />

250 μL 1/16 in. N9302852 29 N9302855 29 N9302858 29<br />

250 μL 1/8 in. N9302867 29<br />

500 μL 1/16 in. N9302853 29 N9302859 29<br />

500 μL 1/8 in. N9302862 29 N9302868 29<br />

1 mL 1/16 in. N9302950 48 N9302953 48 N9302956 48<br />

1 mL 1/8 in. N9302962 26 N9302965 28<br />

2 mL 1/16 in. N9302951 48 N9302954 48 N9302957 48<br />

2 mL 1/8 in. N9302960 48 N9302966 29<br />

5 mL 1/16 in. N9302952 48 N9302958 48<br />

5 mL 1/8 in. N9302961 48 N9302967 30<br />

1/8 in. fitting loop for valves with 0.030 in. standard port diameter. 1/16 in. fitting loop for valves with 0.016 in. standard port diameter.<br />

Laboratory Supplies Gas Chromatography<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

169


Laboratory Supplies<br />

Valve Accessories<br />

Adapters<br />

Fused-Silica Adapters<br />

These adapters allow connection of fused-silica to unions, valve ports, and reducers.<br />

Gas Chromatography Laboratory Supplies<br />

Description i.d. Colum i.d. Fitting Part No. Each (€)<br />

0.5 mm 0.18 mm - 0.35 mm 1/16 in. N9302846 49<br />

Fused-Silica Tubing<br />

Stainless Steel Nut<br />

Valve Body<br />

Air Actuators<br />

Rotor<br />

0.6 - 0.8 mm 0.53 mm 1/16 in. N9302847 49<br />

Any 1/16 in. N9302850 6<br />

0.5 mm 0.18 mm - 0.35 mm 1/16 in. N9302848 28<br />

0.6 - 0.8 mm 0.53 mm 1/16 in. N9302849 28<br />

Any 1/16 in. N9302886 6<br />

Removable Polyimide Liner<br />

Polyimide<br />

Ferrule<br />

Slot<br />

Standard Port Diameter<br />

For Use With Degree Rotation Part No. Each (€)<br />

3- and 4-port valves 90° N9302882 293<br />

6-port valves 60° N9302881 293<br />

8-port valves 45° N9302825 293<br />

10-port valves 36° N9302827 293<br />

Actuator Knob<br />

Part No. N9302913<br />

Actuator Knob<br />

Manual knob allows manual switching of valves. Can be used<br />

with any valve or standoff listed,<br />

except closemount assembly.<br />

Air Actuator Extension Kit<br />

Angle Bracket<br />

Part No. N9300090<br />

Extension screw allows easy tightening of<br />

the air actuator to the standoff. Required<br />

on AutoSystem Series/Clarus GC.<br />

Closemount<br />

Part No. N9302908<br />

Part No.<br />

Part No.<br />

Each (€)<br />

N9302913 18<br />

Each (€)<br />

N9300088 18<br />

Angle Bracket<br />

General purpose bracket for<br />

mounting standoff and actuators.<br />

Closemount Assembly<br />

Allows close mounting of actuator and valve. Primarily used<br />

for mounting valve outside oven. (Not<br />

to be used with manual actuator knobs) Part No. Each (€)<br />

Restrictor<br />

Rotor Removal Tool<br />

Part No.<br />

At ambient conditions, flows range<br />

from 2-200 mL/min. (inlet at 15 psi).<br />

Includes: stainless steel lines (18 in.<br />

long, 1/16 in. o.d., 0.020 in. i.d.) and<br />

inlet filter.<br />

Part No. Each (€)<br />

Magnet end allows easy removal<br />

of rotor from valves.<br />

Each (€)<br />

N9300090 27<br />

N9302908 42<br />

N9302823 210<br />

Part No.<br />

Each (€)<br />

N9302914 7<br />

170


Laboratory Supplies<br />

Valve Accessories<br />

Special Standoff for 10-Port Valve<br />

This standoff will allow connection<br />

of a 10-port 1/8 in. valve to the<br />

AutoSystem Series/Clarus GC.<br />

Part No. Each (€)<br />

N9302781 54<br />

Starter Kit<br />

Part No. Each (€)<br />

N9302821 427<br />

Standoffs<br />

A standoff supports both the actuator and the valve.<br />

The standoff places the valve at the specific distance<br />

from the actuator. A 4 1/8 in. standoff is recommended<br />

for mounting valves in PerkinElmer GC ovens. Standoff<br />

and actuator sold separately.<br />

Length Part No. Each (€)<br />

2 in. N9302909 51<br />

3 1/4 in. N9302910 51<br />

4 1/8 in. N9302911 51<br />

6 in. N9302912 51<br />

Kits<br />

Sample Loop<br />

Air Actuator<br />

Mounting Kit<br />

Solenoid Kit<br />

Fitting<br />

Solenoid<br />

Sample Valve<br />

Mounting Bracket<br />

Column<br />

Kit includes all necessary hardware to install valves on<br />

AutoSystem Series/Clarus GC. Each kit is capable of<br />

mounting up to two gas valves inside the oven. Includes<br />

detailed instructions that show how to use gas valves,<br />

set up timed events, and configure<br />

the AutoSystem GC software.<br />

Part No. Each (€)<br />

N6120033 395<br />

Kit is required for each air actuator. Solenoid Kit allows<br />

precise pulse of air needed to drive air actuator. Kit<br />

includes instructions. For use with<br />

AutoSystem Series/Clarus GC only. Part No. Each (€)<br />

N6120032 287<br />

Kit includes:<br />

Description Qty. Part No.<br />

2u Screen Filter for use with 6 N9302880<br />

Replacement Filters for N9302879<br />

Filter Union 1/16 in. with Removable 1 N9302879<br />

Screen for use with Gas Line Filter<br />

Reducer 1/8 in. Swagelok to 1/16 in. 4 N9302917<br />

Valco for Packed Column Adapter<br />

Reducer 1/8 in. Swagelok Male Nut 2 N9302844<br />

to 1/16 in. Valco<br />

for Injector/Detector Adapter<br />

Stainless Steel Tubing, 50 cm, 2 N9302922<br />

1/16 in. o.d. to 0.02 in. i.d.<br />

for Carrier to detector<br />

Stainless Steel Tubing, 125 cm, 2 N9300087<br />

1/16 in. o.d. to 0.02 in. i.d.<br />

for Sample Input/Output<br />

Valco Ferrule 1/16 in. 10 N9302835<br />

Valco Nut 1/16 in.* 6 N9302832<br />

* Cannot be used with fused-silica adapters (N9302846 or N9302847).<br />

Tubing Kits<br />

Particulate contamination is the leading cause of valve<br />

failure. This tubing has been washed and precleaned, with<br />

solvent and microfiltered steam from deionized water to<br />

remove organic and ionic particulate contamination.<br />

Each kit contains two pieces of 1/16 in. o.d. S/S tubing.<br />

0.02 in.<br />

Length Part No. Each (€)<br />

20 cm N9302871 11<br />

30 cm N9302872 10<br />

50 cm N9302922 17<br />

125 cm N9300087 114<br />

Laboratory Supplies Gas Chromatography<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

171


Laboratory Supplies<br />

Valve Fittings<br />

Gas Sampling Valve Fittings<br />

Ferrules<br />

Description Qty. Part No. Each (€)<br />

1/16 in. stainless steel pkg. 1 N9302835 5<br />

1/8 in. stainless steel pkg. 1 N9302836 5<br />

Gas Chromatography Laboratory Supplies<br />

Plugs and Caps<br />

Reducers<br />

3/8 in. HEX<br />

1/4 in. HEX<br />

Standard Nuts<br />

Unions<br />

1/4 in. HEX<br />

1/4 in. HEX<br />

7/16 in. HEX<br />

7/16 in. HEX<br />

Description Qty. Part No. Each (€)<br />

1/16 in. plug pkg. 1 N9302918 8<br />

1/8 in. plug pkg. 1 N9302919 8<br />

1/16 in. cap pkg. 1 N9302920 10<br />

1/8 in. cap pkg. 1 N9302921 10<br />

Description Qty. Part No. Each (€)<br />

1/8 in. Swagelok TM to 1/16 in. Valco pkg. 1 N9302917 24<br />

1/16 in. adapter for 1/16 in. port pkg. 1 N9302843 14<br />

Description Qty. Part No. Each (€)<br />

1/16 in. pkg. 1 N9302832 5<br />

1/8 in. pkg. 1 N9302833 3<br />

Description Qty. Part No. Each (€)<br />

1/16 in. to 1/32 in. reducing union pkg. 1 N9302838 60<br />

1/16 in. union pkg. 1 N9302839 36<br />

1/8 in. to 1/16 in. reducing union pkg. 1 N9302840 36<br />

1/8 in. union pkg. 1 N9302841 17<br />

172


TotalChrom<br />

Software<br />

TotalChrom Data Handling Systems<br />

Chromatography Data Systems<br />

A proven solution with leading edge productivity.<br />

Streamlining Your Laboratory Workflow<br />

The entire process, from setting up an analytical method<br />

to the final approval of reports, is a streamlined series of<br />

operations in TotalChrom.<br />

TotalChrom features TC Publisher, a powerful application<br />

that extends report capabilities beyond the standard<br />

templates by providing a sophisticated laboratory report<br />

generator using standardized tools. Unique features let<br />

you graphically format the exact report as needed without<br />

extensive training or special commands. It ensures that<br />

the stages of chromatographic analysis, report generation<br />

and distribution are quick, easy, and complete.<br />

low resolution image<br />

TotalChrom Navigator Screen<br />

PerkinElmer’s TotalChrom Chromatography Data System is<br />

designed to provide laboratories with the total answer to<br />

chromatography data-handling needs.<br />

Acquiring, processing, reporting, reviewing, and approving<br />

data is a streamlined series of operations in PerkinElmer’s<br />

TotalChrom Chromatography Data Systems (CDS), software<br />

designed to fit your laboratory workflow and maximize<br />

productivity. With its scalable architecture, 21 CFR Part<br />

11 compliance features and proven algorithms, TotalChrom<br />

offers a computing strategy to manage your chromatography<br />

data quickly and securely in both regulated and<br />

non-regulated environments.<br />

When configured with a PerkinElmer Clarus 500 Gas<br />

Chromatograph or a PerkinElmer Series 200 Liquid<br />

Chromatograph, the TotalChrom Data System is the<br />

controller and data manager for the overall system. In addition,<br />

TotalChrom can also control selected instruments from other<br />

vendors and can acquire data from<br />

any chromatographic system<br />

through A/D interface.<br />

Report templates can perform calculations between different<br />

peaks in the same sample or even between samples, as<br />

well as automate statistical determination for replicate<br />

injections, with full control over the output format.<br />

Quickly and Easily Navigate,<br />

Review, and Approve Your Data<br />

In the “paper world,” reports need to be reviewed and<br />

signed. The TotalChrom Review & Approve (R&A) feature<br />

is a Graphical Reviewing environment that allows intuitive<br />

navigation into data and reports, and provides for the<br />

implementation of a data approval cycle. With TotalChrom<br />

R&A, chromatograms, raw data, results, and reports can<br />

be easily viewed and compared at a glance. Reviewing and<br />

approving reports can be done electronically, with multiple<br />

levels of authority and secure electronic signatures.<br />

High-throughput applications have dramatically increased the<br />

amount of information produced every day in a laboratory.<br />

This feature streamlines tedious data review by using one<br />

single environment to navigate into data, just like we, every<br />

day, navigate into e-mail.<br />

TCPublisher<br />

Replicate Injections Report<br />

TotalChrom Client/Server (TC<br />

C/S) Data System is the solution<br />

in multi-user environments. TC<br />

C/S systems can easily integrate<br />

all existing chromatographs into a<br />

single networked system supporting<br />

an unlimited number of users<br />

and an unlimited number<br />

of chromatographs.<br />

TCPublisher<br />

Single Injection Report<br />

TCPublisher<br />

Dual Channel Report<br />

www.perkinelmer.com/<strong>supplies</strong> 173


Software<br />

Intelligent Interfaces<br />

Software<br />

Gas Chromatography<br />

dotLINK<br />

dotLINK – Interfacing with ease.<br />

All totalchrom systems utilize PerkinElmer Intelligent<br />

Interfaces to connect each chromatography system to the<br />

data system PC. Each interface contains buffered RAM<br />

memory to maintain data collection in the event that the PC<br />

or PC network becomes inoperative during data acquisition.<br />

Data from instruments is never lost and chromatograph<br />

productivity is preserved.<br />

Analog chromatographs connect to TotalChrom through<br />

NCI (Network Chromatograpy Interface) Series Intelligent<br />

Interfaces. The model NCI 901 is a single-channel device,<br />

while the model NCI 902 is a dual-channel device. Both<br />

interface models are capable of taking analog detector data<br />

(unipolar or bipolar) at sampling rates from 0.1 to 100 Hz.<br />

dotLINK is a Windows ® CE-based interface that allows you<br />

to connect your Clarus GC, Agilent 1100 GC, Agilent 6890 GC,<br />

and Series 200 HPLC directly to the network. Designed to face<br />

today’s workload challenges and provide Ethernet connectivity,<br />

dotLINK allows external buffering with a minimal need for<br />

validation. The dotLINK box integral link has a small<br />

footprint, providing valuable space for your laboratory.<br />

dotLINK supports the following GC and HPLC configurations:<br />

Maximum of 3 PerkinElmer Clarus GCs<br />

Maximum of 1 PerkinElmer Series 200 HPLC System Stack<br />

Maximum of 2 Agilent 6890 GCs<br />

Maximum of 1 Agilent 1100 HPLC/UV System Stack<br />

dotLINK<br />

Recommended<br />

Model Applications Memory Part No. Each (€)<br />

dotLINK 1-3 Clarus 500 GCs 1 MB N5150060 3314<br />

Integral Link<br />

Integral Link for Clarus GC<br />

Provides a digital-to-digital connection between the Clarus<br />

GC and TotalChrom. Requires AutoSystem XL IPM for<br />

TotalChrom Workstation or Client/Server Software.<br />

Also requires appropriate cable for<br />

connection to TotalChrom system. Part No. Each (€)<br />

N6513010 887<br />

Integral LINK for Clarus GC and<br />

TotalChrom Workstation Software<br />

Provides digital-to-digital connection between the Clarus<br />

GC and TotalChrom Chromatography Workstation or the<br />

Clarus 500 Mass Spectrometer. Includes Integral LINK,<br />

TotalChrom Workstation Software,<br />

AutoSystem XL IPM, and serial cable. Part No. Each (€)<br />

Analog Board with Integral LINK*<br />

Description Part No. Each (€)<br />

Analog Board with Integral LINK N6513060 1153<br />

Analog Board with Integral LINK N6513070 4844<br />

and TotalChrom Workstation Software<br />

* For ARNEL Analyzers only.<br />

NCI Intelligent Interfaces<br />

NCI Series Intelligent Interfaces are 24 bit, either single or<br />

dual-channel, buffered, A/D converters which have softwareselectable<br />

input voltage ranges of 10, 2, 1, and 0.1 V with 6<br />

decade dynamic range, programmable sampling rates from<br />

0.1 to 100 points per second selectable in TotalChrom<br />

software, less than 1 microvolt noise (peak to peak), 0.1%<br />

linearity, three sense input lines, and one-system READY<br />

relay for communication with Autosamplers. Includes: a<br />

board containing seven programmable relays and a<br />

Rack/Vial Port (TTL voltage levels) for reading Autosampler<br />

vial BCD information. Memory is segmentable for multiple<br />

chromatograms. Software selectable symmetric bipolar or<br />

unipolar mode operation. All Interfaces carry a 1-year<br />

return to Service Depot warranty.<br />

Model NCI 901 Intelligent Interface<br />

with RVP/Relay Board<br />

Single-channel A/D with 256KB RAM memory and RVP/<br />

Relay board. Stores up to 120K data points. Unipolar/<br />

bipolar operation modes. Requires but does not include<br />

one IEEE or RS232 interface cable. Includes power cord.<br />

Voltage Part No. Each (€)<br />

120 V S9000070<br />

240 V S9000075 2671<br />

Model NCI 902 Intelligent Interface<br />

with RVP/Relay Board<br />

N6513020 3756<br />

Dual-channel A/D with 256KB RAM memory and RVP/<br />

Relay board. Stores up to 120K data points. Unipolar/<br />

bipolar operation modes. Requires but does not include<br />

one IEEE or RS232 interface cable. Includes power cord.<br />

Voltage Part No. Each (€)<br />

120 V S9000090<br />

240 V S9000095 4010<br />

174


Software<br />

Intelligent Interfaces<br />

Power Cords – 240 V<br />

No charge when ordered with 240 V Interface.<br />

Country Part No. Each (€)<br />

UK, Cyprus, Nigeria, Zimbabwe, Singapore, 09991414 41<br />

Malaysia, Zambia<br />

Australia, New Zealand 09991417 23<br />

Europe, Saudi Arabia, Egypt, South Africa, India, 09991415 30<br />

Thailand, China<br />

Denmark, Greenland 09991416 27<br />

Switzerland, Liechtenstein 09991413 25<br />

SoftLINK<br />

SoftLINK – Entry-level solution for instrument connectivity.<br />

Designed for workstation environments, SoftLINK TM provides<br />

instrument connectivity at a glance. SoftLINK is able to<br />

control 1 Series 200 HPLC/UV or up to 3 Clarus GC.<br />

SoftLINK/TotalChrom Workstation Software<br />

Includes: appropriate cable for connection of SoftLINK to<br />

TotalChrom system, TotalChrom<br />

software, and Clarus 500 GC IPM.** Part No. Each (€)<br />

SoftLINK Software Kit<br />

Includes: appropriate cable for connection to TotalChrom<br />

system, SoftLINK software CD,<br />

utilities CD, and the install sheet. Part No. Each (€)<br />

USB to Serial Adapter for SoftLINK<br />

One serial port is required for each<br />

Clarus 500 GC. Additional ports can<br />

be added via this USB converter.<br />

** SoftLINK is not available with PerkinElmer-ARNEL systems.<br />

N6513040 3098<br />

N6520235 106<br />

Part No.<br />

Each (€)<br />

09410077 79<br />

Software Gas Chromatography<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

175


Software<br />

Interface Modules<br />

Interface Personality Modules (IPM)<br />

Interface Validation Modules (IVM)<br />

Gas Chromatography Software<br />

IPMs are instrument-specific software programs that<br />

interpret and translate instrument control and data<br />

acquisition parameters between TotalChrom TM and a specific<br />

digital instrument. IPMs are downloaded from the host PC<br />

(TotalChrom) by a configuration function to a specific port.<br />

(Serial or Ethernet) on a dotLINK interface (internal or<br />

external). Downloaded IPMs are stored in nonvolatile<br />

memory in the dotLINK interface.<br />

IPM for AutoSystem, AutoSystem XL,<br />

and Clarus GCs<br />

Provides control for the PerkinElmer AutoSystem Series<br />

and Clarus GCs and their associated liquid Autosampler,<br />

with simultaneous digital data acquisition from two inboard<br />

detectors. Utilizes one serial port on a dotLINK interface and<br />

may be configured to any port or ports on any LINK interface<br />

or interfaces connected to a single TotalChrom acquisition<br />

system. For TotalChrom Professional<br />

users, v4.0 or higher is required, but Part No. Each (€)<br />

not included.<br />

N5150160 494<br />

IPM for Agilent 5890 Series II and Agilent 5890A GCs<br />

Provides control for the Agilent Series 5890 GCs and their<br />

associated liquid Autosamplers, with simultaneous digital<br />

data acquisition from two inboard detectors. Utilizes one<br />

serial port on a Model 600 LINK Series interface and a<br />

second port for each associated Autosampler that is to be<br />

controlled. This IPM may be configured to any port or ports<br />

on any LINK interface or interfaces connected to a single<br />

TotalChrom acquisition system. Requires one serial cable<br />

for each connected Agilent GC and one serial cable for<br />

each connected Autosampler. For TotalChrom Professional<br />

users, v4.0 or higher is required, but not included. Note:<br />

Each Agilent 5890 and 7673 autosampler must have the<br />

appropriate Agilent serial external<br />

controller card(s) and remote start Part No. Each (€)<br />

cable installed.<br />

N5150165 494<br />

IPM for Agilent 6890/6890Plus<br />

Provides control for the Agilent Series 6890 GCs and their<br />

associated liquid Autosampler, with simultaneous digital<br />

data acquisition from two inboard detectors. Utilizes one<br />

serial port on a dotLINK. This IPM may be configured to<br />

any port or ports on any LINK interface or interfaces<br />

connected to a single TotalChrom acquisition system. It is<br />

recommended that no more than two Agilent 6890 GCs be<br />

configured per workstation LINK interface. Requires one<br />

serial cable for each connected Agilent<br />

GC. Control of the Agilent 6890/<br />

Part No. Each (€)<br />

6890Plus is not available for TC Pro. N5150166 494<br />

Model 520 Interface Validation Module, 120 V<br />

The Model 520 IVM is a calibrated analog peak pattern<br />

generator for use in testing/validating analog to digital<br />

converters such as the NCI 901/902 and the Series 900/900A<br />

Intelligent Interfaces. The module generates eight possible<br />

analog patterns at selectable voltage ranges of 0-0.1, 0-1, 0-2,<br />

and 0-10 volts. Factory calibration is traceable to a NIST<br />

standard volt. Includes remote start/stop cable and analog<br />

signal cable for connection to PerkinElmer NCI/900/900A<br />

Series Intelligent Interfaces. Includes 1-year return to<br />

Service Depot warranty.<br />

Voltage Part No. Each (€)<br />

120 V S9000160<br />

240 V S9000165 2586<br />

TotalChrom Workstation Model 520 IVM Software<br />

Allows user to test any NCI Series and M900A Series<br />

Intelligent Interfaces to validate interface operations<br />

(linearity, reproducibility, etc.). Contains special TotalChrom<br />

interface test methods and automated validation logs to<br />

maintain results of interface tests in software.<br />

Requires, but does not include, a<br />

Model 520 Interface Validation Module. Part No. Each (€)<br />

N5150181 314<br />

176


Software<br />

Serial Cables<br />

IEEE Cables – All TC Versions<br />

Serial Cables<br />

Cable Length Part No. Each (€)<br />

1 m 65105001 153<br />

2 m 65105102 173<br />

4 m 65105204 184<br />

8 m 65105408 230<br />

External Communications Cable<br />

Shielded DB9 Male/Female 9-pin<br />

external RS-232 communications cable.<br />

For M941/M600 LINK Interfaces<br />

Cable Length Part No. Each (€)<br />

7 ft. S5010021 32<br />

25 ft. S5010022 38<br />

50 ft. S5010023 51<br />

100 ft. S5010024 64<br />

For M950/970 Interfaces<br />

Cable Length Part No. Each (€)<br />

7 ft. S5010017 32<br />

25 ft. S5010018 38<br />

50 ft. S5010019 51<br />

100 ft. S5010020 64<br />

For NCI Interfaces<br />

Cable Length Part No. Each (€)<br />

7 ft. S5010037 63<br />

25 ft. S5010038 71<br />

50 ft. S5010039 64<br />

100 ft. S5010040 77<br />

For dotLINK Interfaces<br />

Cable Length Part No. Each (€)<br />

10 ft. 09290144 19<br />

25 ft. 09290145 47<br />

For M941A and M600/610 Link Interfaces<br />

Cable Length Part No. Each (€)<br />

7 ft. S5010025 46<br />

25 ft. S5010030 52<br />

50 ft. S5010031 64<br />

100 ft. S5010032 77<br />

For NCI Interfaces<br />

Part No.<br />

TotalChrom TM WS and C/S Serial<br />

Cables to Lantronix Terminal Server<br />

TotalChrom WS and<br />

C/S Serial Cables to PC<br />

Cable Length Part No. Each (€)<br />

7 ft. S5010033 46<br />

25 ft. S5010034 52<br />

50 ft. S5010035 64<br />

100 ft. S5010036 77<br />

Agilent 6890 – HS40/ATD400 Ready/Run Cables<br />

Each (€)<br />

N6500133 181<br />

Description Part No. Each (€)<br />

Cable Kit, HS40/ATD400 to Agilent 6890 N6100410 149<br />

Cable Kit, M950/970 Series Interface to Agilent 6890 N6100411 159<br />

Serial Cables* for Instrument Interface<br />

Description Part No. Each (€)<br />

PerkinElmer Clarus GC to dotLINK, 10 ft. 09290146 19<br />

PerkinElmer Clarus GC to dotLINK, 25 ft. 09290147 47<br />

PerkinElmer Clarus GC 65609010 223<br />

to M600/M610 LINK, 10 ft.<br />

PerkinElmer Clarus GC 65609025 300<br />

to M600/M610 LINK, 25 ft.<br />

M900/960/970 Series Interface to M600/M610 S5010013 223<br />

LINK, 6 ft. (not for M941)<br />

NCI Series Interface to dotLINK, 7 ft. S5010037 63<br />

NCI Series Interface to M600/M610 LINK, 6 ft. S5010041 223<br />

Agilent 1100 GC-Autosampler to dotLINK, 10 ft. 09290144 19<br />

(Required quantity: 3)<br />

Agilent 1512A Autosampler Controller S5010015 223<br />

(on 5890GC) to M600/M610 LINK, 10 ft.<br />

Agilent 1512A Autosampler Controller S5010016 300<br />

(on 5890GC) to M600/M610 LINK, 25 ft.<br />

Agilent 5890A/Series II GC 65605810 223<br />

to M600/M610 LINK, 10 ft.<br />

Agilent 6890 GC/-Agilent 6890Plus GC- 09290144 19<br />

Autosampler to dotLINK, 10 ft.<br />

Agilent 6890 GC/-Agilent 6890Plus GC- 09290145 47<br />

Autosampler to dotLINK, 25 ft.<br />

Agilent 6890 GC/-Agilent 6890Plus GC- S5010015 223<br />

Autosampler to M600/M610 LINK, 10 ft.<br />

Agilent 6890 GC/-Agilent 6890Plus GC- S5010016 300<br />

Autosampler to M600/M610 LINK, 25 ft.<br />

Agilent 7673A Autosampler Controller 65607610 223<br />

(on 5890GC) to M600/M610 LINK, 10 ft.<br />

Agilent 7673A Autosampler Controller 65607625 300<br />

(on 5890GC) to M600/M610 LINK, 25 ft.<br />

* Special serial cards, instrument communication kits, and IPM software<br />

may be required to complete interfacing of a LINK interface to a digital<br />

chromatograph. Please contact your local PerkinElmer Sales Representative<br />

for details.<br />

M900 Series BCD Cables for Autosamplers<br />

Description Part No. Each (€)<br />

PerkinElmer HS100, HS101, ATD50, AS2000, AS8300 65204501 230<br />

Software Gas Chromatography<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

177


Software<br />

Software Kits<br />

Serial Communications<br />

Cards for TurboChrom<br />

TotalChrom Workstation<br />

SI/DI Upgrade Kits<br />

Gas Chromatography Software<br />

Agilent 5890A/Series II GC<br />

Description Part No. Each (€)<br />

Serial Card S2000203 2360<br />

Agilent 7673A Controller<br />

Description Part No. Each (€)<br />

Remote Start Cable S2000206 102<br />

Serial Card and Control Board S2000205 2928<br />

Serial Card and EPROM S2000204 638<br />

TotalChrom Workstation Manuals<br />

Application Manager’s Guide<br />

Application Manager’s Guide covering<br />

installation and system management<br />

of TotalChrom Workstation software.<br />

Manual Set<br />

Complete manual set including User’s<br />

Guide (volumes 1 and 2), Application<br />

Manager’s Guide, and Tutorial.<br />

TotalChrom Tutorial<br />

Software tutorial that teaches basic data acquisition, method<br />

development, optimization techniques,<br />

sequence development, and calibration. Part No. Each (€)<br />

User’s Guide (Volumes 1 and 2)<br />

User’s manual covering instrument<br />

configuration and basic operation<br />

of TotalChrom TM Workstation software.<br />

Part No.<br />

Each (€)<br />

N5156025 128<br />

Part No.<br />

Each (€)<br />

N5150512 383<br />

N5156021 70<br />

Part No.<br />

Each (€)<br />

N5150518 255<br />

v6.x Workstation Migration to v6.3.x Workstation<br />

Migrates an existing TurboChrom TM Workstation<br />

v4.x or v6.x acquisition system, and associated RPO<br />

systems, to TotalChrom Workstation v6.3.x software.<br />

Requires verification of ownership of TurboChrom<br />

v6.x software. Software supplied on<br />

CD-ROM media v4.x or v6.x.<br />

Part No. Each (€)<br />

N5150349 1140<br />

v6.2.x Workstation Migration to v6.3.x Workstation<br />

Migrates an existing TotalChrom Workstation v6.2.x<br />

acquisition system, and associated RPO systems, to<br />

TotalChrom Workstation v6.3.x software. Requires<br />

verification of ownership of TotalChrom v6.2.x software.<br />

Software supplied on CD-ROM media.<br />

Part No. Each (€)<br />

TotalChrom Workstation Software<br />

N5150715 855<br />

Description Part No. Each (€)<br />

Multi-Instrument Software Kit N5150103 3704<br />

Reprocess-Only Software Kit N5150100 542<br />

178


Thermal Desorbers<br />

TurboMatrix Thermal Desorbers<br />

TurboMatrix<br />

Thermal Desorbers for GC<br />

... driving unrivaled Performance<br />

through Innovation.<br />

Thermal desorption is a technique that simplifies and speeds a wide range of gas<br />

chromatography (GC) applications, including indoor and outdoor air monitoring, analysis<br />

of outgassing from semiconductor materials, polymers, upholstery and furnishings,<br />

packaging, pharmaceuticals, and analysis of flavors and fragrances.<br />

As the undisputed market leader in GC sample handling, we took the next step to offer you<br />

even more benefits for your lab. PerkinElmer offers a family of five different TurboMatrix TM<br />

Thermal Desorber (TD) models in both single-tube and automated 50-tube configurations:<br />

■ TurboMatrix 100 TD – single-tube and manual pneumatics<br />

■ TurboMatrix 150 ATD – 50-tube autosampler and manual pneumatics<br />

■ TurboMatrix 300 TD – single-tube and programmable pneumatic control<br />

■ TurboMatrix 350 ATD – 50-tube autosampler and programmable pneumatic control<br />

■ TurboMatrix 650 ATD – 50-tube autosampler, programmable pneumatic control<br />

and a variety of other accessories for a wide range of applications<br />

This broad offering allows you to match technology<br />

to your laboratory and applications needs.<br />

Confirmatory Analysis<br />

The TurboMatrix 650 ATD allows samplesplit<br />

re-collection on same or different<br />

tubes, delivering the ability to audit<br />

samples and perform confirmatory<br />

analysis and repeat analysis under a<br />

different set of conditions.<br />

Integrity Testing<br />

Sensors monitor all aspects of system<br />

operation to ensure that the instrument<br />

is working as it should and provide an<br />

early indication of possible problems<br />

with the analysis. Analytical techniques<br />

such as tube and trap impedance testing<br />

and the standard addition options help<br />

ensure sample integrity. All of these<br />

are designed to provide the user with<br />

the highest confidence in the final<br />

analytical results.<br />

Reduced Cost Per Sample<br />

The TurboMatrix Thermal Desorbers<br />

save money and minimize laboratory<br />

waste. After each use, all sample tubes<br />

can be reconditioned and conveniently<br />

reused. The system provides cryogenfree<br />

operation down to -30 °C, reducing<br />

operating costs. Unlike other techniques,<br />

thermal desorption requires no solvents,<br />

thus reducing cost, risk of contamination,<br />

analyst exposure and the need for<br />

solvent disposal.<br />

Maximize Sample Throughput<br />

Since the thermal desorber unit can<br />

run simultaneously with the GC, you<br />

can start your next desorption run as<br />

the GC processes the previous run for<br />

maximum productivity.<br />

■ Improved chromatography and narrow peak widths<br />

as a result of 40 °C per second trap heating rate<br />

■ Higher productivity with overlapping tube<br />

desorption and chromatography<br />

■ Wider boiling range analysis and improved water<br />

management using the backflush mode, where<br />

multiple adsorbents can be used in series<br />

■ Uncompromised narrow-bore capillary<br />

chromatography due to rapid desorption<br />

of the focusing trap (40 °C per second)<br />

179


Thermal Desorbers<br />

Ozone Precursor Accessories<br />

Gas Chromatography Thermal Desorbers<br />

Air Toxics Columns<br />

Methyl Silicone Column<br />

For use with Air Toxics TM (T014)<br />

Analyzer System with FID/ECD<br />

detectors. 100 m x 0.32 mm i.d. x 5 μm.<br />

Methyl Silicone Column<br />

The STS 25 is used for sequential sampling of air onto a<br />

series of up to 24 ATD sample tubes. It is a portable unit<br />

and can be operated either by a 12 V battery or 120/240 V.<br />

The sampler includes cables with jack plug connectors<br />

(for use with the monitoring pump) and a set of diffusion<br />

limiting caps. The STS 25 requires but does not include<br />

sample tubes and a monitoring<br />

pump. Also requires a 12 V<br />

Part No. Each (€)<br />

battery or an electrical adapter.<br />

L4280001 6600<br />

12 V Rechargeable Battery<br />

Waterproof, suitable for outdoor use.<br />

Air Monitoring Pump<br />

120 V<br />

Cable<br />

For connecting the STS-25 to<br />

a generic 12 V battery.<br />

Part No.<br />

Each (€)<br />

N6300155 1836<br />

For use with the Air Toxics (T014) Analyzer System<br />

with Mass Spectrometer<br />

60 m x 0.32 mm i.d. x 5 μm.<br />

Part No. Each (€)<br />

Model STS 25 Sequential<br />

Tube Sampler<br />

Model STS 25 Accessories<br />

N9316000 993<br />

Part No.<br />

Each (€)<br />

L4280002 548<br />

Part No.<br />

Each (€)<br />

L4271275 2810<br />

Part No.<br />

Each (€)<br />

L4285007 121<br />

Diffusion Limiting Caps<br />

(pkg. 5)<br />

Electrical Adapter<br />

Allows for direct connection to wall<br />

outlet. Also acts as a battery charger<br />

for 12 V battery (120/240 V).<br />

Personal Monitoring Pump<br />

Description Size Part No. Each (€)<br />

5-100 mL/min. 110 V N6102351<br />

5-100 mL/min. 220 V N6102197 2028<br />

STS 25 Maintenance Kit<br />

Description Part No. Each (€)<br />

Includes: Rotor Tube Seals (pkg. 50), Filter N6609060 504<br />

Disks (pkg. 25), Diffusion Limiting Caps (pkg. 5),<br />

and Rotor Seal (pkg. 10)<br />

Rotor Filter Disk L4281023 5<br />

Viton O-Ring<br />

For use in diffusion limiting cap<br />

and tube seals. (pkg. 50)<br />

Ozone Precursor Accessories<br />

Alumina PLOT TM Column<br />

50 m x 0.32 mm i.d.<br />

ATD 400 Air Monitoring Trap<br />

Low flow trap packed with carbonaceous<br />

sorbents suitable for ozone precursor<br />

and air toxics monitoring. (pkg. 1)<br />

Methyl Silicone Column<br />

50 m x 0.22 i.d. x 1.0 μm<br />

Nafion Dryer<br />

Particulate Filter Kit<br />

Includes disposable filter and fittings.<br />

For use in the ozone precursor analyzer.<br />

Restrictor Tubing<br />

0.10 mm i.d. uncoated, deactivated,<br />

fused-silica restrictor tubing. For<br />

use in the ozone precursor analyzer.<br />

Part No.<br />

Part No.<br />

Part No.<br />

Each (€)<br />

N6301107 2729<br />

Each (€)<br />

L4275108 332<br />

Part No.<br />

Each (€)<br />

N6301108 1518<br />

Part No.<br />

Each (€)<br />

04974414 1193<br />

Part No.<br />

Each (€)<br />

L4285001 108<br />

Part No.<br />

Each (€)<br />

L4280003 453<br />

Part No.<br />

Each (€)<br />

N6300063 255<br />

Part No.<br />

Each (€)<br />

L4275033 147<br />

Each (€)<br />

N9301355 114<br />

180


Thermal Desorbers<br />

Sample Tubes<br />

Caps for TurboMatrix<br />

Brass Long-Term Storage Caps<br />

Recommended for long-term storage.<br />

Two required per tube. Also requires<br />

Teflon ferrule (L1003015). (pkg. 1)<br />

Combined Teflon Ferrule<br />

For use with 1/4 in. Brass Long-term<br />

Storage Cap (09908851). Two (2)<br />

required per tube. (pkg. 1)<br />

Diffusion Caps – Standard<br />

For passive air sampling to ensure<br />

correct diffusion path length. (pkg. 10)<br />

Diffusion Caps with Membrane<br />

Same as above but with a<br />

silicone membrane. (pkg. 10)<br />

Pen Clips<br />

For stainless steel ATD tubes. (pkg. 10)<br />

PFA Teflon Ferrules for<br />

TurboMatrix Storage End Caps<br />

(pkg. 20)<br />

TurboMatrix Analytical Caps<br />

Required for use on the TurboMatrix<br />

instrument during analysis PTFE Caps<br />

with O-Ring. (pkg. 20)<br />

Replacement Parts for ATD 400<br />

Tube Seal and Tube<br />

Part No.<br />

Each (€)<br />

09908851 4<br />

Part No.<br />

Each (€)<br />

L1003015 7<br />

Part No.<br />

Each (€)<br />

L4070207 164<br />

Part No.<br />

Each (€)<br />

L4070208 588<br />

Part No.<br />

Each (€)<br />

L4071029 31<br />

Part No.<br />

Each (€)<br />

M0413625 218<br />

Part No.<br />

Each (€)<br />

N6200119 280<br />

Description Qty. Part No. Each (€)<br />

1<br />

Packed Sample Tube(s)*<br />

1 Sample Tube(s)*<br />

2<br />

Packing Retaining Gauzes 100 L4071034 114<br />

3<br />

Retaining Springs 50 L4071123 86<br />

4<br />

Chamfer Holder O-Ring 1 04973727 2<br />

5<br />

Tube Seal O-Ring 10 04972383 1<br />

6<br />

Grip Seal O-Ring 50 04970343 15<br />

7<br />

Nozzle Filter Disk 1 L4271159 2<br />

3<br />

* See Sample Tube product listing above.<br />

6<br />

2 2<br />

4 5 1 5 7<br />

Sample Tubes for TurboMatrix<br />

Packed Sample Tubes for TurboMatrix<br />

Pkg. Stainless Steel Glass<br />

Qty. Sorbent Part No. Each (€) Part No. Each (€)<br />

10** Air Toxics Tube N9307001 871 N9307008 871<br />

10** Carbopack B 60/80 N9307002 871 N9307009 871<br />

10** Carbopack B 60/80 N9307000 871 N9307007 871<br />

Carbopack C 60/80<br />

Carbosieve SIII 60/80<br />

10** Carbosieve SIII 60/80 N9307003 871 N9307010 871<br />

10** Chromasorb 106 N9307006 871 N9307013 871<br />

10** NIOSH 2549 tube N9307038 871 N9307037 871<br />

10** Tenax GR 60/80 N9307004 871 N9307011 871<br />

10** Tenax TA 60/80 N9307005 871 N9307012 871<br />

** Shipped with brass long-term storage caps.<br />

Packed Sample Tubes<br />

for TurboMatrix<br />

Empty Sample Tubes with Caps<br />

Glass Lined<br />

Pkg. Stainless Steel Stainless Steel Glass<br />

Qty. Part No. Each (€) Part No. Each (€) Part No. Each (€)<br />

10* M0413597 739 M0413595 340 M0413598 368<br />

50* M0413596 1518<br />

* Shipped with Analytical End Caps (N6200119).<br />

Empty Sample Tubes Without Caps<br />

Pkg. Stainless Steel Glass<br />

Qty. Part No. Each (€) Part No. Each (€)<br />

10 L4270128 224 L4071594 249<br />

100 L4270129 2244<br />

Thermal Desorbers Gas Chromatography<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

181


Thermal Desorbers<br />

Thermal Desorber Supplies<br />

Gas Chromatography Thermal Desorbers<br />

Cold Traps, Fittings,<br />

and Accessories<br />

ATD 400 Air Monitoring Trap<br />

Low flow trap (L4275107) packed with carbonaceous<br />

sorbents suitable for ozone precursor<br />

and air toxics monitoring. (pkg. 1) Part No. Each (€)<br />

ATD Cold Trap Nuts<br />

Two required per trap tube. (pkg. 1)<br />

Cold Trap Tube (packed)<br />

Standard cold trap packed<br />

with CarbopackC.<br />

Cold Trap Tube (Low Flow) Unpacked<br />

Cold trap with reduced bore at one<br />

end. Allows minimum gas flow<br />

during trap desorption. (pkg. 1)<br />

Low Flow Cold Trap<br />

Cold Trap Tube (Tenax TA)<br />

Standard cold trap (L4271106)<br />

packed with Tenax TA 60/80. (pkg. 1)<br />

Cold Trap Tube (Unpacked)<br />

Standard cold trap tube unpacked.<br />

(pkg. 1)<br />

Graphite Ferrule<br />

Ferrule for cold trap. Recommended<br />

for all applications except those using<br />

Mass Spectrometer or ECD. (pkg. 2)<br />

PTFE Ferrule<br />

Ferrules for cold trap. Recommended<br />

for use with Mass Spectrometer<br />

or ECD. (pkg. 10)<br />

Note: New ferrules are required<br />

when trap is changed.<br />

L4275108 332<br />

Part No.<br />

Each (€)<br />

N6200150 317<br />

Part No.<br />

Each (€)<br />

L4275107 248<br />

0.7 mm Sorbents Quartz Wool 2.8 mm<br />

Glass Fiber<br />

Disks<br />

Part No.<br />

Packing Retaining Spring<br />

Part No.<br />

Each (€)<br />

L4275089 126<br />

Part No.<br />

Each (€)<br />

L4275009 59<br />

Each (€)<br />

L4271106 92<br />

Part No.<br />

Each (€)<br />

L4271187 5<br />

Part No.<br />

Each (€)<br />

L4275110 9<br />

Consumables Starter Kit<br />

Thermal Desorber Starter Kit<br />

The starter kit is recommended for all<br />

purchasers who do not already have a<br />

TurboMatrix Thermal Desorber.<br />

Includes:<br />

Description Qty. Part No.<br />

Glass Wool pkg. 1 54120790<br />

Tenax TA 60-80, Mesh – 15 g pkg. 1 04978064<br />

Packing Gauze pkg. 100 L4071034<br />

Retaining Spring pkg. 50 L4071123<br />

Stainless Steel Sample Tubes pkg. 10 M0413595<br />

Glass Sample Tube pkg. 10 M0413598<br />

PTFE Filter Discs, Large pkg. 10 L1003029<br />

PTFE Filter Discs pkg. 10 L1003030<br />

Graphite Ferrules pkg. 2 L4271187<br />

Trap Tube Nuts pkg. 2 L4275009<br />

Trap Tubes pkg. 2 M0410094<br />

Gauze Loading Supplies<br />

Gauze Loading Rig<br />

Correctly positions gauze at both ends of stainless steel<br />

sampling tubes. Highly recommended<br />

when packing sample tubes.<br />

Part No. Each (€)<br />

Replacement Plastic Plunger<br />

for Gauze Loading Device<br />

(pkg. 5)<br />

Interface Cables for ATD 400<br />

Nelson 900 Series<br />

Interface Box Cable<br />

Also transmits BCD.<br />

Ready/Start Cable<br />

Also transmits BCD.<br />

Interface Kit<br />

Thermal Desorber GC Interface Kit<br />

Part No.<br />

Each (€)<br />

M0413541 4845<br />

L4070023 2168<br />

Part No.<br />

Each (€)<br />

L4071151 60<br />

Part No.<br />

Part No.<br />

Each (€)<br />

L4270034 210<br />

Each (€)<br />

L4270032 159<br />

Contains all necessary hardware for connecting the heated<br />

transfer line to either 1/8 in. packed or<br />

capillary columns inside the GC oven. Part No. Each (€)<br />

L4270026 838<br />

182


Thermal Desorbers<br />

Thermal Desorber Supplies<br />

Thermal Desorber to<br />

Agilent 6890 GC Ready Start Cable<br />

Connects a TurboMatrix thermal<br />

desorber to an Agilent 6890<br />

or Agilent 6850 GC.<br />

Manual<br />

TurboMatrix Thermal Desorber<br />

User’s Manual<br />

Miscellaneous Accessories<br />

Backflush Nozzle Accessory<br />

Graphite Vespel Ferrule<br />

1/16 in. x 0.5 mm i.d. For connection<br />

of 0.32 mm i.d. transfer line to ATD.<br />

(pkg. 1)<br />

Internal Standard Injection Accessory<br />

To allow the introduction of a<br />

gaseous internal standard.<br />

Liquid Nitrogen Accessory<br />

For operation of the cold trap to -100 °C.<br />

Note: Requires a pressurized Dewar with a relief valve set at 25 psig<br />

(180 kpa). Dewar must have a 1/4 in. Swagelok TM connection. Also<br />

requires a pressure relief valve set at 50 psig<br />

(350 kpa) in pipe between Dewar and ATD 400. Part No.<br />

Regulator 0-60 psig<br />

The standard 0-30 psig regulator can be replaced with this<br />

0-60 psig regulator to expand the choice of column and<br />

application range. Installation by a<br />

PerkinElmer Service Engineer is<br />

required, but not included.<br />

Part No.<br />

N6101474<br />

Each (€)<br />

300<br />

Valco Graphite Vespel Ferrule<br />

For use on Valco TM valve. 1/16 in. i.d.<br />

(pkg. 1)<br />

Part No.<br />

Each (€)<br />

N6100410 149<br />

Part No.<br />

Each (€)<br />

M0413331 93<br />

Part No.<br />

Each (€)<br />

L4275072 217<br />

Part No.<br />

Each (€)<br />

04972066 7<br />

Part No.<br />

Each (€)<br />

L4270010 4056<br />

Each (€)<br />

L4270009 1836<br />

Part No.<br />

Each (€)<br />

04974018 8<br />

TurboMatrix ATD Sample Carousel<br />

Fifty (50) position tube carousel<br />

for use on the TurboMatrix ATD.<br />

Mobile Seal Assembly<br />

Description Part No. Each (€)<br />

Mobile Seal O-Ring, Viton 009 L1003006 1<br />

Mobile Seal O-Ring, Viton 010 04970343 15<br />

Nozzle Filter Disc (pkg. 1) L4271159 2<br />

Software<br />

TurboMatrix TD/ATD PC Control Software Rev 1.1<br />

Provides full external control of a TurboMatrix thermal<br />

desorber from a personal computer running under Windows ®<br />

95, 98, or NT. Methods and sequences can be generated,<br />

stored, edited, printed, and executed. Functions include<br />

diagnostics, user defined access levels, run reports, and<br />

transfer of vial identification to TotalChrom, allowing<br />

complete data traceability. On-screen<br />

interactive help function is available. Part No. Each (€)<br />

Cable included (M0417035).<br />

M0413559 740<br />

TurboMatrix TD/ATD Remote Control Software<br />

Rev 1.1 (for WIN 2000)<br />

Provides full external control of a TurboMatrix thermal<br />

desorber from a personal computer running under Windows<br />

95, 98, or NT. Methods and sequences can be generated,<br />

stored, edited, printed, and executed. Functions include<br />

diagnostics, user defined access levels, run reports, and<br />

transfer of vial identification to TotalChrom, allowing<br />

complete data traceability. On-screen<br />

interactive help function is available. Part No. Each (€)<br />

Cable included (M0417035).<br />

N6200210 819<br />

Trap Supplies<br />

Part No.<br />

Each (€)<br />

M0413380 234<br />

Description Part No. Each (€)<br />

Ceramic Washer M0415339 9<br />

Cold Trap O-Ring 09200091 30<br />

Heat Conduction Bushing M0410316 8<br />

Filter Disk (pkg. 1) L1003030 47<br />

PTFE filter on either side of cold trap<br />

Packing Disk (pkg. 20) L4271290 16<br />

Glass fiber disk for separating sorbents when<br />

packing cold trap with multiple sorbents<br />

Packing Retaining Spring (pkg. 5) N6301054 29<br />

For low flow trap<br />

Packing Tool L4271203 24<br />

Graphite Ferrule (pkg. 2) L4271187 5<br />

Ferrule for cold trap. Recommended for all<br />

applications except those using Mass Spec or ECD<br />

Gripper Insert Replacement (pkg. 2) M0413645 64<br />

Heated Transfer Line M0413644 1314<br />

Standard length 45 in.<br />

Heated Transfer Line M0413558 1454<br />

Long length 70 in.<br />

Thermal Desorbers Gas Chromatography<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

183


Thermal Desorbers<br />

Thermal Desorber Supplies<br />

Gas Chromatography Thermal Desorbers<br />

Thermal Desorber Empty Trap (pkg. 1) M0413627 238<br />

Thermal Desorber Packed Trap N6200150 317<br />

Trap packed with CarbopackC<br />

TurboMatrix Air Monitoring Trap (pkg. 1) M0413628 317<br />

Trap packed with carbonaceous sorbents suitable<br />

for ozone precurser and air toxics monitoring<br />

TurboMatrix Thermal Desorber Packed Trap (pkg. 1) M0413535 334<br />

Trap packed with Tenax TM TA<br />

PTFE Ferrule L4275110 9<br />

Ferrules for cold trap. Recommended for use with<br />

Mass Spec or ECD. (pkg. 10)*<br />

Trap Filter Disk<br />

PTFE filter on either side of cold trap. (pkg.1) L4271160 5<br />

Trap Heat Conduction Bushing and Ceramic Washer M0410316 8<br />

* New ferrules are required when trap is changed.<br />

TurboMatrix Upgrade Kits<br />

Internal Standard Addition/Tube Dry Purge Add-On Kit<br />

Adds capability to introduce a known quantity of a gaseous<br />

standard into the sample tube prior to desorption to verify<br />

analyte recovery. Standard gas is added to the tube in the<br />

sampling direction, allowing use of tubes packed with<br />

multiple adsorbents.<br />

Note: Requires, but does not include, an Options<br />

Board when added to the entry-level thermal<br />

desorber. Installation by PerkinElmer Service<br />

is required, but not included.<br />

Part No.<br />

M0413555<br />

Each (€)<br />

5300<br />

Liquid Nitrogen Cooling Add-On Kit<br />

For operation of the cold trap to -100 °C. Requires, but does<br />

not include, the options board when added to entry-level<br />

thermal desorber. Requires a pressurized Dewar with a relief<br />

valve set at 25 psig (180 kpa). Dewar must have a 1/4 in.<br />

Swagelok connection. Also requires a pressure relief<br />

valve set at 50 psig (350 kpa) in pipe between Dewar and<br />

TurboMatrix. Installation by<br />

PerkinElmer Service is required,<br />

Part No. Each (€)<br />

but not included.<br />

M0413557 1951<br />

On-Line Sampling Add-On Kit<br />

Adds capability to perform on-line sampling of ambient<br />

air directly to the electrically cooled trap. Overlapping<br />

sampling and GC analysis allows collection of air for<br />

analysis up to 50 minutes of every hour. Includes sample<br />

valve, Nafion drier, dry air purge control, and pump.<br />

Air Toxics trap is installed.<br />

Note: Requires, but does not include, an Options Board when added to<br />

entry-level thermal desorber. Allows thermal desorber to still be used for<br />

tube desorption. Installation by PerkinElmer<br />

Service is required, but not included.<br />

Part No. Each (€)<br />

M0413556 13200<br />

Options Board/BCD Output Board<br />

Required for installation of the following options on an entrylevel<br />

thermal desorber – Internal Standard Addition, On-Line<br />

Sampling, or Liquid Nitrogen Cooling. Also provides output<br />

of BCD information regarding tube position numbers and<br />

provides relay output for timed control of external devices.<br />

Note: This board is included as standard on the<br />

automated thermal desorber. Installation by<br />

PerkinElmer Service is required, but not included.<br />

Part No.<br />

M0413551<br />

Each (€)<br />

988<br />

Thermal Desorber to<br />

Automated Thermal Desorber Upgrade Kit<br />

Includes parts to upgrade an entry-level thermal desorber<br />

to an automated thermal desorber for unattended analysis<br />

of up to 50 samples. Includes BCD output communication<br />

capabilities and timed event relays for timed control of<br />

external devices. Installation<br />

by PerkinElmer Service<br />

Part No. Each (€)<br />

is required, but not included.<br />

M0413553 16600<br />

TurboMatrix Upper Seal Assembly<br />

Description Qty. Part No. Each (€)<br />

Low Temp (< 225 °C), pkg. 10 L1003006 1<br />

Viton ® 009 O-Rings<br />

Low Temp (< 225 °C), pkg. 10 L1003008 5<br />

Viton 011 O-Rings<br />

High Temp (> 225 °C), pkg. 1 M0415361 88<br />

Kalrez ® 011, Large Seal O-Ring<br />

High Temp (> 225 °C), pkg. 1 M0415360 80<br />

Kalrez 009, Small Seal O-Ring<br />

Fixed Upper Seal, Graphite Ferrule 09920593 27<br />

TurboMatrix Thermal Desorber High Temperature Kit<br />

Contains all the necessary hardware for operation of the<br />

valve at temperatures starting at 150 °C up to 300 °C.<br />

Service is required, but not included.<br />

Part No. Each (€)<br />

M0413646 1212<br />

184


PerkinElmer, the undisputed leader in Inductively<br />

Coupled Plasma Mass Spectrometry (ICP-MS), is<br />

the preferred choice for atomic spectroscopy solutions<br />

and services in thousands of laboratories globally.<br />

The PerkinElmer SCIEX ELAN product line of ICP-MS<br />

instruments sets the standard for ICP-MS ultratrace<br />

analysis. Whether you choose instruments based on<br />

classic quadrupole technology or instruments that utilize<br />

patented Dynamic Reaction Cell interference-reduction<br />

technology, every application challenge can be met.<br />

Inductively Coupled Plasma – MS


Inductively Coupled Plasma – MS<br />

QUICK-FIND INDEX Page #<br />

Baffled Cyclonic Spray Chambers 202<br />

Concentric Nebulizers 196<br />

Cooling Systems/Chillers 189<br />

Cyclonic Spray Chambers 203<br />

Demountable Quartz Torches 205<br />

Detectors 190<br />

ELAN Consumables Kits 193<br />

ELAN Software 206<br />

GemClean Crossflow II Nebulizers 197<br />

Injector Support Adapters 195<br />

Injectors 194<br />

Ion Optics 190<br />

Peristaltic Pump Tubing 199<br />

PFA Teflon Nebulizers 196<br />

RF Load Coils 205<br />

Sampler and Skimmer Cones 189<br />

PerkinElmer offers a wide selection of superior quality products designed to work with<br />

your PerkinElmer instruments. Our precision-designed products deliver the peace of<br />

mind that comes from knowing that you’ll get the results you need.<br />

The Quick Find Index to the left will help you find products fast. For your convenience,<br />

products are alphabetized by category, sub-category, and family. There is also a more<br />

complete Alphabetical INDEX on page 429 and a Part Number INDEX on page 407.<br />

Cones<br />

Ion Lenses<br />

Precision designed and manufactured large-orifice Sampler<br />

and Skimmer Cones provide superior, long-term stability and<br />

resist clogging, allowing analysis under both high and low<br />

sample-uptake conditions. PerkinElmer's Sampler and<br />

Skimmer Cones are available in Nickel and Platinum for<br />

all ELAN models.<br />

Page 189<br />

PerkinElmer offers the industry's only Single Ion Lens with<br />

the exclusive SwiftMount TM II Cassette Lens Mount. The plug<br />

and play design makes changing the Ion Lens faster and<br />

simpler than ever before. No tools are required as the<br />

design incorporates a clean capture-and-release concept.<br />

Page 190<br />

Scott Spray Chambers 204<br />

Speciation by Chromatography 207<br />

Standards 209<br />

Nebulizers<br />

PerkinElmer offers a wide selection of nebulizers for use<br />

with your ELAN. From our exclusive GemClean design to<br />

standard concentric, PFA Teflon and ultrasonic nebulizers,<br />

you can choose the option that best fits your instrument<br />

and your analysis.<br />

Page 196<br />

Spray Chambers<br />

The spray chamber is responsible for filtering the sample<br />

mist to permit the appropriate droplet size distribution to<br />

reach the plasma. PerkinElmer offers a large selection of<br />

Baffled Cyclonic, Cyclonic and Scott models. Cyclonic and<br />

Baffled Cyclonic models are available in Standard, O-Ring<br />

Free and Water-Cooled versions. Scott models are available<br />

in PFA Teflon, Water-Cooled and Ryton versions.<br />

Page 202


The ELAN Family Sets the Standard<br />

for ICP-MS Ultratrace Analysis<br />

For over 20 years, PerkinElmer and SCIEX<br />

have partnered to develop and distribute the<br />

most innovative and powerful ICP-MS systems.<br />

There are over 2500 ICP-MS systems installed in industries ranging from<br />

environmental and clinical to semiconductor, geochemical and metallurgical,<br />

making PerkinElmer SCIEX the industry leader in ICP-MS.<br />

As the undisputed market leader in ICP-MS, PerkinElmer SCIEX continues<br />

to provide innovative solutions to evolving customer needs:<br />

■ NEW quick-change torch cassette –<br />

changing the torch components is a very<br />

simple process – no tools are required<br />

■ NEW SwiftMount II – the snap-in-place<br />

design makes lens removal or installation<br />

a two-finger approach<br />

■ NEW oil-drain system – changing the oil<br />

in the mechanical vacuum pumps is now<br />

easier and cleaner, using the integrated<br />

valve and thread-on valve extension<br />

■ NEW improved detector lifetime – new<br />

detector electronics enable operation at<br />

lower detector voltages, thereby extending<br />

detector lifetime<br />

ELAN 9000<br />

ELAN ® 9000<br />

Optimizes routine ultratrace analysis<br />

The ELAN 9000 ICP-MS instrument is<br />

perfect for laboratories looking to take<br />

advantage of the powers of detection<br />

of an ICP-MS. It incorporates proven<br />

ICP-MS technology based on 40 years of<br />

innovation and listening to our customers.<br />

The ELAN 9000 simplifies ICP-MS by<br />

providing an easy-to-use, easy-to-maintain<br />

tool for routine ultratrace level analysis.<br />

It is ideal for environmental, clinical,<br />

geochemical and general testing<br />

laboratories with moderate to heavy<br />

loads of ultratrace-level samples.<br />

The proven design of the ELAN 9000<br />

ICP-MS ensures accuracy, improves<br />

method development and consistently<br />

delivers the correct answer, reducing<br />

rework and improving productivity.<br />

Design enhancements provide increased<br />

reliability and reduced cost of ownership,<br />

when compared with other ICP-MS systems.<br />

ELAN DRC-e<br />

Expanding the capabilities of ICP-MS<br />

When your applications extend beyond the<br />

capabilities of conventional quadrupole<br />

ICP-MS, you need the power of the<br />

innovative ELAN DRC-e. The DRC-e<br />

brings the interference-eliminating power<br />

of patented Dynamic Reaction Cell TM<br />

(DRC) technology and performanceenhancing<br />

Axial Field TM Technology (AFT)<br />

to the industry-proven ELAN ICP-MS<br />

system. The result is uncompromised<br />

sensitivity and performance in a robust<br />

system designed for routine laboratories.<br />

Combined with a robust HF-resistant<br />

sample introduction system and the<br />

purpose-designed productivity enhancing<br />

features of the ELAN ICP-MS system, the<br />

maintenance-free Dynamic Reaction Cell<br />

provides a system with uncompromised<br />

performance that is rugged, reliable and<br />

easy-to-use — a must for today’s highthroughput<br />

production environments.<br />

ELAN DRC II<br />

The ultimate in ICP-MS performance<br />

When your applications extend beyond<br />

the capabilities of conventional ICP-MS,<br />

you need the power of the ELAN DRC II.<br />

The ELAN DRC II combines the power of<br />

patented Dynamic Reaction Cell (DRC)<br />

technology, performance-enhancing Axial<br />

Field Technology (AFT) and a highperformance<br />

sample introduction system<br />

with the ability to run any reaction gas.<br />

The result is the ultimate analytical tool,<br />

providing uncompromised sensitivity<br />

and performance in all matrices for the<br />

world’s most difficult applications.<br />

Unlike collision-cell, high-resolution<br />

or cool-plasma systems, the ELAN<br />

DRC II completely eliminates polyatomic<br />

interferences, minimizing background<br />

equivalent concentrations, while<br />

maintaining analyte sensitivity,<br />

providing ultratrace-level detection<br />

limits in virtually any sample.<br />

187


Autosampler and Flow Injection Supplies<br />

Sample Trays, Probes, Tubing, and Accessories<br />

Inductively Coupled Plasma – MS Autosampler and Flow Injection<br />

Autosampler Supplies and<br />

Accessories for ICP-MS<br />

Please see pages 8-10 for our full selection of Sample Trays, Sample Vessels,<br />

Probes, Tubing, and Accessories.<br />

FIAS-400MS Supplies<br />

and Accessories<br />

Please see pages 21-28 for our full selection of Cells, Connectors, Tubing<br />

Valves, and Accessories.<br />

Flow Injection Analysis Upgrade Kit<br />

For use with ELAN 9000/6X00/DRC instruments. It enables<br />

the standard FIAS-400 and FIAS-200 systems to be used for<br />

ICP-MS. Includes ELAN read cable and<br />

the FIAS-400MS hardware manual.<br />

Part No. Each (€)<br />

N8120119 293<br />

ELAN 9000/6X00 FIAS Vapor Adapter Kit<br />

This kit includes all the tubing and connections to connect<br />

the gas-liquid separator to the torch, when doing hydride<br />

generation work. The Vapor<br />

Adapter Kit is included with<br />

the FIAS-400MS system.<br />

Part No.<br />

B0505540<br />

Each (€)<br />

580<br />

Preconcentration Connector Kit<br />

For use with the FIAS-400MS flow injection system. Includes<br />

special connectors and tubing for preconcentration with<br />

ICP-MS. Additionally required, but not included: C18 or<br />

XAD-8 Preconcentration Columns and<br />

Five-port Sampling Valve. Service<br />

installation is recommended.<br />

Part No.<br />

B0508593<br />

Each (€)<br />

1161<br />

Preconcentration Columns<br />

For use with FIA Preconcentration.<br />

Description Qty. Part No. Each (€)<br />

C18 10 B0504047 689<br />

XAD-8 10 B0504048 689<br />

Gilson 222 Accessories<br />

Adapter Plate For Gilson Racks<br />

Required to adapt Gilson 222<br />

style racks to the AS-93plus.<br />

Gilson 222 Teflon Sampling Probe Kit<br />

Includes 1.25 mm i.d. Teflon-lined<br />

sample probe with a bored-out holder.<br />

UltraClean Sampling<br />

Probes and Accessories<br />

UltraClean Sampling Probes<br />

UltraClean Probe<br />

For use with the AS-9x<br />

Autosampler. For ultratrace<br />

analysis with<br />

PFA-ST Concentric<br />

Nebulizer (N8122192).<br />

Requires CTFE Union<br />

(N8122355) to connect<br />

to PFA-ST nebulizer.<br />

Dimension Flow Rate Part No. Each (€)<br />

0.5 mm i.d. 400 μL/min. N8122361 230<br />

0.25 mm i.d. 100 μL/min. N8122360 230<br />

CTFE Union<br />

Part No. N8122360<br />

Part No.<br />

Necessary to connect UltraClean Autosampler Probe<br />

(N8122360 and N8122361) with PFA-ST Teflon<br />

Concentric Nebulizer (N8122192).<br />

Part No.<br />

Each (€)<br />

B3140647 48<br />

Part No.<br />

Each (€)<br />

N8122170 268<br />

Each (€)<br />

N8122355 38<br />

188


Mass Spectrometer Hardware<br />

Cones and Cooling Systems<br />

Cones and Accessories<br />

Precision designed and manufactured large-orifice Sampler<br />

and Skimmer Cones provide superior, long-term stability<br />

and resist clogging, allowing analysis under both high and<br />

low sample-uptake conditions.<br />

Nickel Sampler<br />

Part No. WE021140<br />

Nickel Sampler and Skimmer Cones<br />

ELAN Model Type Part No. Each (€)<br />

9000/6X00/DRC Sampler WE021140 542<br />

9000/6X00/DRC Skimmer WE021137 689<br />

5000 Sampler WE013087 363<br />

5000 Skimmer N8122000 536<br />

Platinum Sampler<br />

Part No. WE027802<br />

Nickel Skimmer<br />

Part No. WE021137<br />

Platinum Skimmer<br />

Part No. WE027803<br />

Platinum Sampler and Skimmer Cones<br />

ELAN Model Type Part No. Each (€)<br />

9000/6X00/DRC Sampler WE027802 1722<br />

9000/6X00/DRC Skimmer WE027803 1977<br />

5000 Sampler N8122025 2245<br />

5000 Skimmer N8122035 4043<br />

Sampler and Skimmer Cone O-Rings<br />

ELAN Model Type Qty. Part No. Each (€)<br />

9000/6X00/DRC Sampler 5 N8120511 14<br />

9000/6X00/DRC Skimmer 5 N8120512 8<br />

5000 Sampler 1 N8122003 9<br />

5000 Sampler 20 N8120114 147<br />

5000 Skimmer 1 N8122002 9<br />

5000 Skimmer 20 N8120113 147<br />

Cone Removal Tool<br />

ELAN Model Part No. Each (€)<br />

9000/6X00/DRC WE017142 351<br />

5000 N8122040 210<br />

Sampler Cone Aluminum Gasket<br />

One aluminum gasket for<br />

ELAN 5000 Sampler Cones.<br />

Cooling Systems<br />

Chillers/Recirculating Water Cooling Systems<br />

Chillers for the ELAN 5000/6X00/DRC systems. Designed<br />

to handle process temperatures from -10° to 40 °C (14° to<br />

104 °F), they feature convenient “one-touch” temperature<br />

control and bright LED readouts which can be easily read,<br />

even from across the room –<br />

and let you check temperature<br />

set point and fluid flow rate<br />

and/or pressure with just a<br />

quick touch.<br />

For added operational safety,<br />

they also feature audible<br />

and visual alarms that alert<br />

you instantly when operating<br />

parameters – such as fluid<br />

temperature, flow rate,<br />

fluid pressure, and ambient<br />

temperature – exceed preset<br />

limits. There are even useradjustable<br />

high and low<br />

temperature limits to help<br />

prevent unauthorized set<br />

point changes plus built-in<br />

safeties to alert you to low<br />

fluid levels and thermal runaway.<br />

Requires the use of ELAN Coolant Fluid (WE016558).<br />

Power<br />

Requirement Operating Temp Flow Rate Part No. Each (€)<br />

208 - 230 V, -15° to 40 °C 60 psi: N0772026 4029<br />

60 Hz, 8 A 4.3 gpm/<br />

16.3 Lpm<br />

240 V, -15° to 40 °C 60 psi: N0772025 4029<br />

50 Hz, 8.5 A 4.3 gpm/<br />

16.3 Lpm<br />

Heat Exchanger System<br />

Part No.<br />

Cooling systems for the ELAN 9000/DRC II/e systems.<br />

Air cooled recirculator without refrigeration. Not to be<br />

placed in areas with temperatures above 30 °C (86 °F).<br />

Requires the use of ELAN Coolant Fluid (WE016558).<br />

Each (€)<br />

WE012989 16<br />

Power Requirement Part No. Each (€)<br />

120 V, 60 Hz N8122248 2265<br />

220/250 V, 50/60 Hz N8122247 2300<br />

Mass Spectrometer Hardware Inductively Coupled Plasma – MS<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

189


Mass Spectrometer Hardware<br />

Cooling Systems, Detectors, and Ion Optics<br />

Inductively Coupled Plasma – MS Mass Spectrometer Hardware<br />

Heavy Organics Chiller<br />

For all ELANs. Refrigerated recirculating system capable of<br />

maintaining the heavy organic sample introduction system<br />

(N8122132) at -20 °C.<br />

Power Requirements Part No. Each (€)<br />

240 V, 50 Hz N8122193 4591<br />

120 V, 60 Hz N8122194 4591<br />

ELAN Coolant Fluid<br />

1 liter bottle. It is essential that this chiller coolant be used<br />

with ELAN 9000/6X00/DRC series<br />

instruments. Also suitable<br />

for organics chillers.<br />

Part No.<br />

WE016558<br />

Each (€)<br />

29<br />

Detectors<br />

SimulScan Dual-Stage Detector<br />

The dual-stage detector is an integral part of the ELAN<br />

SimulScan TM system. It measures both high- and low-level<br />

analytes simultaneously. This conserves valuable or limited<br />

samples, eliminates the need to perform time-consuming<br />

sample dilutions, and allows you to quickly characterize<br />

unknown samples. Designed specifically for use with the<br />

ELAN 9000/6X00/DRCs.<br />

Service installation is<br />

Part No. Each (€)<br />

required, but not included.<br />

N8125001 3469<br />

Detector Electronics Upgrade Kit<br />

For ELAN 9000/6X00/DRCs manufactured before April 2005.<br />

Boosts detector life at least 20%.<br />

Service installation required,<br />

but not included.<br />

Part No.<br />

W1013195<br />

Each (€)<br />

126<br />

Ion Optics<br />

PerkinElmer offers the<br />

industry’s only Single<br />

Ion Lens with the<br />

exclusive SwiftMount TM<br />

II Cassette Lens Mount.<br />

The plug and play<br />

design makes changing<br />

the Ion Lens faster and<br />

simpler than ever<br />

before. No tools are<br />

required as the design<br />

incorporates a clean<br />

capture-and-release<br />

concept. In fact, the<br />

process takes less than<br />

60 seconds, while competitive lens systems that have 30<br />

to 40 pieces are very difficult to clean and reassemble.<br />

And since the lens is only one piece, there is no need to<br />

restabilize the system after cleaning.<br />

Cassette Ion Lens Upgrade Kit<br />

Slide and Click demountable lens assembly for all ELANs<br />

manufactured before April 2005.<br />

Includes all mounting hardware,<br />

ShadowStop TM , and a Series II Lens.<br />

Part No.<br />

W1017871<br />

Each (€)<br />

1268<br />

Series II Ion Lens<br />

Contains a demountable single ion replacement lens for<br />

either the Series II or Cassette Lens Assembly for ELAN<br />

9000/6X00/DRCs manufactured<br />

between January 1998 and April 2005. Part No. Each (€)<br />

Ion Lens<br />

Replacement ion lens for use with early model ELAN 6000s<br />

manufactured before January 1998 that do not have the<br />

Series II lens upgrade. In addition,<br />

some instruments may require<br />

Feed-thru Connector (WE016510).<br />

Part No.<br />

WE014777<br />

Each (€)<br />

172<br />

Cassette Lens ShadowStop<br />

The PerkinElmer SCIEX<br />

patented ShadowStop prevents<br />

photons and un-ionized matrix<br />

constituents from entering the<br />

quadrupole, lowering system<br />

background, and eliminating drift.<br />

This innovation also enhances<br />

ease-of-use because the<br />

ShadowStop is grounded,<br />

making it a passive part of the<br />

ion optic design.<br />

Replacement ShadowStop for use with the Cassette Lens<br />

Mount. For use with ELAN 9000/DRCs<br />

manufactured after April 2005.<br />

Part No. Each (€)<br />

Series II ShadowStop<br />

Replacement ShadowStop for use with ELAN 9000/6100/<br />

DRCs and the Series II Lens Assembly on all ELAN 6000s<br />

manufactured between January 1998<br />

and April 2005.<br />

Part No. Each (€)<br />

Series II Lens Removal Tool<br />

Flexible shaft driver with<br />

removable 2 mm Hex Ball Bit.<br />

2 mm Hex Ball Bit<br />

For use with Series II Lens<br />

Removal Tool (W1010620).<br />

WE018034 319<br />

W1013361 70<br />

WE029011 208<br />

Part No.<br />

Each (€)<br />

W1010620 62<br />

Part No.<br />

Each (€)<br />

W1010598 11<br />

190


Mass Spectrometer Hardware<br />

Mass Flow Controllers<br />

Mass Flow Controllers<br />

Multichannel Mass Flow Controller<br />

For the ELAN 9000/6X00 series of instruments. 3-channel<br />

Mass Flow Controller (MFC) assembly for computer control<br />

of the Plasma, Auxiliary, and Nebulizer gas flows on the<br />

ELAN 6X00/9000. Not for ELAN DRCs. Contains control<br />

unit, software, cabling, tubing, and 2 MFC heads. The internal<br />

MFC from the ELAN is used as the nebulizer channel.<br />

(For instruments manufactured prior to January 1996, the<br />

ELAN 5000 MFC Head, Part No. N8122074 is also required.)<br />

A fourth channel is also available as an extra option.<br />

The computer-controlled fourth channel can be 2 L/min.<br />

(WE018079) for use as a plasma make-up gas when using<br />

certain sampling accessories. Requires software v2.1 or<br />

greater. Service installation is required, but not included.<br />

Power Requirement Part No. Each (€)<br />

110 V, 60 Hz WE018076 16500<br />

220 V, 50 Hz WE018355 17300<br />

Fourth Channel 2 L/min. MFC Option<br />

For the ELAN 9000/6X00 series of instruments. 0-2 L/min.<br />

Mass Flow Controller for use as a plasma make-up gas when<br />

using certain sampling accessories. Not suitable for use with<br />

oxygen. Requires the Multichannel Mass Flow Controller<br />

(WE018076 or WE018355).<br />

Part No. Each (€)<br />

Secondary Nebulizer Gas Mass Flow<br />

Controller Assembly<br />

WE018079 6610<br />

For the ELAN 9000/6X00 series. Free-standing singlechannel<br />

0-2 L/min. Mass Flow Controller for the secondary<br />

(make-up) nebulizer gas flow used with certain sampling<br />

accessories, e.g., low sample uptake<br />

nebulizers. Not suitable for use with<br />

oxygen. Not computer-controlled.<br />

Part No.<br />

N8120503<br />

Each (€)<br />

6100<br />

Mass Flow Controller Assembly<br />

for Organic Sampling System<br />

For the ELAN 9000/6X00 series. A free-standing 0-200<br />

mL/min. Mass Flow Controller for control of the oxygen<br />

flow when using the organic sampling<br />

system. Not computer controlled. Part No. Each (€)<br />

N8120161 6400<br />

Plasma/Aux Gas Mass Flow Controller Upgrade Kit<br />

For the ELAN DRC II and DRC-e. Kit includes two 0-2 L/min.<br />

and 0-20 L/min. Mass Flow Controllers for the Plasma and<br />

Aux gases. Service installation<br />

is required, but not included.<br />

Part No. Each (€)<br />

WE028426 6800<br />

Make-up Gas Mass Flow Controller Upgrade Kit<br />

For the ELAN DRC II and DRC-e. Kit includes one 0-2 L/min.<br />

Mass Flow Controller for the computer controlled addition of<br />

a make-up gas into the plasma. Not for<br />

use with oxygen. Service installation is<br />

required, but not included.<br />

Part No.<br />

WE028427<br />

Each (€)<br />

2571<br />

Oxygen Gas Mass Flow Controller Upgrade Kit<br />

For the ELAN DRC II and DRC-e. Kit includes one 0-200<br />

mL/min. Mass Flow Controller for the computer controlled<br />

addition of oxygen gas into the plasma.<br />

For analyzing organic solvents. Service<br />

installation is required, but not included.<br />

Part No.<br />

WE028428<br />

Each (€)<br />

2571<br />

Nebulizer Gas Mass Flow Controller Upgrade Kit<br />

For ELAN 6000. A built-in nebulizer gas, 0-2 L/min.<br />

Mass Flow Controller Kit. This upgrade kit is available<br />

for instruments shipped before<br />

January 1996. Service installation<br />

is required, but not included.<br />

Part No.<br />

WE015772<br />

Each (€)<br />

4910<br />

Mass Spectrometer Hardware Inductively Coupled Plasma – MS<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

191


Mass Spectrometer Hardware<br />

Reaction Gas Accessories<br />

Inductively Coupled Plasma – MS Mass Spectrometer Hardware<br />

DRC Gas Cabinets and Upgrade Kits<br />

DRC Gas Safety Cabinets<br />

For Semiconductor use in North America. Complete Article<br />

80 compliant gas safety cabinet and delivery system for<br />

DRC instruments. 110 V, 60 Hz.<br />

Channels Gas Part No. Each (€)<br />

Single Ammonia only (NH 3 ) N8122385 14000<br />

Dual Ammonia and Oxygen (NH 3 and O 2 ) N8122387 19100<br />

Dual Ammonia and Methane (NH 3 and CH 4 ) N8122388 19100<br />

Axial Field Technology Upgrade Kit<br />

for ELAN DRC to a DRC plus<br />

Includes all hardware necessary to upgrade an ELAN DRC<br />

to a DRC plus . Service installation<br />

required, but not included.<br />

Part No. Each (€)<br />

ELAN DRC-e to DRC II Upgrade Kit<br />

Remote Roughing Pump Kit<br />

Allows placement of the roughing pumps up to 3 meters<br />

away from ELAN DRCs. Service<br />

installation required, but not included. Part No. Each (€)<br />

Stainless Steel Second Reaction<br />

Gas Pneumatics (without getter)<br />

WE027567 9900<br />

Complete upgrade of a DRC-e to a DRC II. Includes<br />

ammonia regulator and solutions. Service installation<br />

required, but not included.<br />

Part No. Each (€)<br />

Second Reaction Gas Pneumatics<br />

W1012771 35700<br />

WE023935 3686<br />

Allows the use of a second Reaction Gas on DRC IIs, which<br />

have stainless steel gas lines and VCR fittings (manufactured<br />

after January 2004). Cannot be used on instruments with<br />

Teflon reaction gas lines (manufactured before January 2004).<br />

Recommended for reaction gases containing oxygen. Includes<br />

precision 0-3 mL/min. metal Mass Flow Controller, orbitally<br />

welded stainless steel tubing<br />

with VCR fittings and valving. Service Part No. Each (€)<br />

installation required, but not included.<br />

W1008680 4999<br />

Second Reaction Gas Pneumatics (without getter)<br />

Allows the use of a second Reaction Gas with ELAN DRC/<br />

DRC plus /DRC-e and DRC IIs which do not have stainless<br />

steel gas lines (manufactured before January 2004).<br />

Recommended for reaction gases containing oxygen.<br />

Includes precision 0-3 mL/min. Mass Flow Controller and<br />

valving. Service installation required, but not included.<br />

ELAN Model Part No. Each (€)<br />

DRC-e/DRC II (Manufactured before January 2004) WE028439 4999<br />

DRC/DRC plus WE024354 4999<br />

Ammonia Reaction Gas Channel<br />

Allows the use of ammonia as a reaction gas with the ELAN<br />

DRC-e. Requires Corrosive Purge Turbomolecular Pump Kit<br />

(WE029013). Includes precision 0-3 mL/min. Mass Flow<br />

Controller, getter, valving, electronics<br />

and foreline trap. Service installation<br />

required, but not included.<br />

Part No.<br />

W1006057<br />

Each (€)<br />

34300<br />

Getter Regeneration Kit for ELAN DRCs<br />

Temperature controller, gas regulator, and<br />

tubing which allows regeneration of the<br />

Reaction Gas getter on DRC instruments.<br />

Vacuum Pumps and Accessories<br />

Corrosive Purge Turbomolecular Pump Kit<br />

for ELAN 9000 and DRC-e<br />

Protects the turbopump from damage caused by the<br />

analysis of samples containing high concentrations of<br />

phosphoric acid and the use of ammonia reaction gas.<br />

Service installation is required, but not included.<br />

ELAN Model Part No. Each (€)<br />

9000/DRC-e WE029013 7100<br />

6X00 WE017603 23600<br />

Vacuum Pump Oil<br />

For use with Roughing Pumps. One gallon (3.8 liters).<br />

Pump Model Part No. Each (€)<br />

Leybold N8122004 293<br />

Varian N8122308 86<br />

High Vacuum Silicon Grease<br />

For lubrication of ELAN 9000/6X00/<br />

5000/DRCs vacuum system O-rings.<br />

Part No.<br />

Each (€)<br />

WE023257 2500<br />

Part No.<br />

Each (€)<br />

09905147 34<br />

192


Sample Introduction<br />

Consumables Kits and Graphite Furnace Supplies<br />

ELAN Consumables Kits<br />

Consumables Kit for ELAN DRC-e/9000/6X00<br />

Typical one year’s supply of consumables for ELAN<br />

DRC-e/9000/6X00. Consists of the following parts:<br />

Consumables Kit for ELAN DRC II<br />

Typical one year’s supply of consumables for ELAN DRC II.<br />

Consists of the following parts:<br />

Descriptions Kit Qty. Part No. Each (€)<br />

Demountable Quartz Torch 2 N8122006 287<br />

RF Coil Assembly 1 WE021816 312<br />

Alumina Injectors, 2.0 mm i.d. 2 N8126041 198<br />

Cross-Flow II Replacement GemTips 1 N8120515 113<br />

Injector Support Adapter 1 N8120116 79<br />

(Assembled with O-Rings)<br />

Internal Injector Support Adapter O-Ring 1 09210011 1<br />

External Injector Support Adapter O-Ring 2 09210012 1<br />

Injector Support Adapter O-Ring 1 N8122010 3<br />

Drain Tubing for Peristaltic Pump 1 N8122012 37<br />

(12/pack)<br />

Peristaltic Pump Sample Tubing 4 09908587 59<br />

(12/pack)<br />

Capillary Tubing (10 feet/pack) 2 09908265 29<br />

Drain Tubing Adapter Connectors 4 09920379 1<br />

Sampler Cone O-Rings 5 WE012687 2<br />

Skimmer Cone O-Rings 5 09902218 1<br />

Nickel Sampler Cones 3 WE021140 542<br />

Nickel Skimmer Cones 3 WE021137 689<br />

Rear Air Filter, Pump Side 1 WE021074 12<br />

Rear Air Filter, ICP Side 1 WE022567 11<br />

Cartridge Water Filter 1 09904846 43<br />

Vacuum Pump Oil, 1 Gallon (Varian) 1 N8122308 86<br />

SimulScan Dual-Stage Detector 1 N8125001 3469<br />

Argon Regulator Filter 1 N8125006 22<br />

Series II Ion Lens 1 WE018034 319<br />

HGA – 600MS Supplies<br />

Part No.<br />

Each (€)<br />

N8120509 7900<br />

Graphite Consumable Parts for the HGA-600MS<br />

Components Part No. Each (€)<br />

1A<br />

Short Contact Cylinders (pkg. 5) B0105111 194<br />

Left-hand electrical contacts<br />

1B<br />

Cooling Rings (pkg. 5) B0155481 191<br />

1C<br />

Probe Tips (pkg. 10) B0508371 146<br />

Threaded tips for sealing the graphite<br />

furnace during vaporization<br />

1D<br />

Tip Holders (pkg. 5) B0508373 87<br />

1E<br />

Long Contact Cylinders (pkg. 5) B0139997 243<br />

Right-hand electrical contacts<br />

1F<br />

Extractor Tubes (pkg. 5) B0508374 179<br />

Sampling valve inserts<br />

1G<br />

Pyrolytically Coated Tubes (pkg. 10) B0135653 403<br />

1 Pyrolytically Coated Tubes (pkg. 50) B0091504 1808<br />

Descriptions Kit Qty. Part No. Each (€)<br />

Demountable Quartz Torch 2 N8122006 287<br />

O-Ring Kit for Injector Support Adapter 3 N8120100 4<br />

RF Coil Assembly 1 WE021816 312<br />

Quartz Ball Joint Injectors, 2.0 mm i.d. 2 WE023948 670<br />

Ball Joint Injector Support Adapter 1 WE023951 168<br />

Internal Injector Support Adapter O-Ring 3 09210011 1<br />

Drain Tubing Adapter Connectors 2 N8122012 37<br />

(12/pack)<br />

Peristaltic Pump Sample Tubing 4 09908587 59<br />

(12/pack)<br />

Capillary Tubing (10 feet/pack) 2 09908265 29<br />

Drain Tubing Adapter Connectors 4 09920379 1<br />

Sampler Cone O-Rings 1 N8120511 14<br />

Skimmer Cone O-Rings 1 N8120512 8<br />

Platinum Sampler Cone 1 WE027802 1722<br />

Platinum Skimmer Cone 1 WE027803 1977<br />

Rear Air Filter, ICP Side 1 WE022567 11<br />

Rear Air Filter, Pump Side 1 WE021074 12<br />

Vacuum Pump Oil, 1 Gallon (Varian) 1 N8122308 86<br />

SimulScan Dual-Stage Detector 1 N8125001 3469<br />

Argon Regulator Filter 1 N8125006 22<br />

Series II Ion Lens 1 WE018034 319<br />

Liquid Connector for Concentric Nebulizers 1 WE024372 110<br />

Teflon Sample Capillary 6 WE024375 1<br />

for Concentric Nebulizers<br />

A<br />

B<br />

D<br />

C<br />

G<br />

Part No.<br />

Each (€)<br />

N8120542 10400<br />

E<br />

F<br />

Sample Introduction Inductively Coupled Plasma – MS<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

193


Sample Introduction<br />

Injectors and Adapters<br />

Inductively Coupled Plasma – MS Sample Introduction<br />

Alumina Injectors<br />

Alumina Injectors are compatible with Twist Type and<br />

Cassette Torch Mounts. They are vacuum baked to<br />

reduce contamination.<br />

Alumina Injector, 2.0 mm i.d.<br />

Shipped standard with the ELAN DRC-e/9000/6X00/5000/<br />

500. For use with HF-resistant (Ryton ® ) sample introduction<br />

system. Standard injector for aqueous<br />

solutions and less volatile<br />

organic solvents.<br />

Part No.<br />

N8126041<br />

Each (€)<br />

198<br />

Alumina Injector Tube, 1.5 mm i.d.<br />

For the ELAN DRC-e/9000/6X00/5000/500. For reduced<br />

sample loading with HF-resistant<br />

(Ryton) sample introduction system.<br />

Part No. Each (€)<br />

N8126040 198<br />

Alumina Injector Tube, 0.85 mm i.d.<br />

For the ELAN DRC-e/9000/6X00/5000/500. Recommended<br />

for use with volatile organic solutions<br />

on the HF-resistant (Ryton) sample<br />

introduction system.<br />

Part No.<br />

N8126039<br />

Each (€)<br />

198<br />

PFA Injector Assemblies<br />

PFA/Quartz Twist Type Torch<br />

Injector Assembly, 1.5 mm i.d.<br />

For use with instruments that have the twist type torch<br />

mount (available on ELAN models manufactured before<br />

April 2005). An economical solution for many non-HF<br />

applications. For direct analysis of organic solvents. 1.5 mm<br />

i.d. Quartz Injector permanently mounted in PFA support.<br />

Use to reduce solvent loading with<br />

PFA Teflon sample introduction<br />

Part No. Each (€)<br />

system and peltier organics kit.<br />

N8122394 350<br />

PFA/Quartz Cassette Torch<br />

Injector Assembly, 1.5 mm i.d.<br />

For use with instruments that have the cassette torch mount<br />

(available on ELAN models manufactured after April 2005).<br />

An economical solution for many non-HF applications.<br />

For direct analysis of organic solvents. 1.5 mm i.d. Quartz<br />

Injector permanently mounted in PFA support. Use to<br />

reduce solvent loading with PFA<br />

Part No. Each (€)<br />

Teflon sample introduction system<br />

and peltier organics kit.<br />

N8122413 350<br />

PFA/Sapphire Twist Type Torch<br />

Injector Assembly, 1.8 mm i.d.<br />

For use with instruments that have the twist type torch<br />

mount (available on ELAN models manufactured before<br />

April 2005). This HF-resistant injector is ideal for most<br />

high purity and low background applications. 1.8 mm i.d.<br />

sapphire injector permanently mounted<br />

in PFA support. For use with PFA Part No. Each (€)<br />

sample introduction system.<br />

N8122358 740<br />

PFA/Sapphire Cassette Torch<br />

Injector Assembly, 1.8 mm i.d.<br />

For use with instruments that have the cassette torch mount<br />

(available on ELAN models manufactured after April 2005).<br />

This HF-resistant injector is ideal for most high purity and<br />

low background applications. 1.8 mm i.d. sapphire injector<br />

permanently mounted in PFA<br />

support. For use with PFA sample Part No. Each (€)<br />

introduction system.<br />

N8122411 740<br />

PFA/Platinum Twist Type Torch Injector Assembly Part No. N8122359<br />

PFA/Platinum Twist Type Torch<br />

Injector Assembly, 2.0 mm i.d.<br />

For use with instruments that have the twist type torch mount<br />

(available on ELAN models manufactured before April 2005).<br />

This HF-resistant injector is recommended for improved<br />

performance for sub to low ppt Al determinations. 2.0 mm<br />

i.d. platinum injector permanently mounted in PFA support.<br />

For use with PFA Teflon sample<br />

introduction system. Not for use<br />

Part No. Each (€)<br />

with hydrogen peroxide.<br />

N8122359 2296<br />

PFA/Platinum Cassette Torch Injector Assembly. Part No. N8122412<br />

PFA/Platinum Cassette Torch<br />

Injector Assembly, 2.0 mm i.d.<br />

For use with instruments that have the cassette torch mount<br />

(available on ELAN models manufactured after April 2005).<br />

2.0 mm i.d. platinum injector permanently mounted in PFA<br />

support. For use with PFA Teflon<br />

sample introduction system. Not<br />

for use with hydrogen peroxide.<br />

Part No.<br />

N8122412<br />

Each (€)<br />

2295<br />

194


Sample Introduction<br />

Injectors and Adapters<br />

Quartz Injectors<br />

Injector Support Adapters<br />

Quartz Injectors are compatible with Twist Type and<br />

CassetteTorch Mounts.<br />

Quartz Ball Joint Injectors<br />

For ELAN DRC/DRC plus /DRC II. For use with pass-through Ball<br />

Joint Injector Support Adapters (WE023951 or W1012406).<br />

Description Recommended Use Part No. Each (€)<br />

2.0 mm i.d. General Purpose WE023948 670<br />

1.5 mm i.d.* Organics WE027005 638<br />

0.85 mm i.d.* Volatile Organics WE027030 638<br />

* For reduced sample loading.<br />

Quartz Injectors<br />

For the ELAN DRC-e/9000/6X00/5000 when using the<br />

HF-Resistant Sample Introduction System (WE024782).<br />

Description Recommended Use Part No. Each (€)<br />

2.0 mm i.d. Clinical Samples N8125029 191<br />

1.6 mm i.d. Organic Solvents 00473292 134<br />

1.2 mm i.d. Organic Solvents N0681631 159<br />

Sapphire Injector<br />

Sapphire Injector Tube, 2.0 mm i.d.<br />

For the ELAN DRC-e/9000/6X00/5000. Demountable<br />

injector for use with the HF-resistant (Ryton) sample<br />

introduction system. Not for use with<br />

PFA sample introduction system. Part No.<br />

Each (€)<br />

N0695495 995<br />

Ball Joint Twist Type Torch Injector Support Adapter<br />

For ELAN DRC/DRC plus /DRC II. Pass-through design for use<br />

with ball joint injectors. For use with twist type torch mounts<br />

(manufactured before April 2005).<br />

Part No. Each (€)<br />

Ball Joint Cassette Torch Injector Support Adapter<br />

Twist Type Torch Injector Support Adapter<br />

Twist Type Torch Injector Support Adapter<br />

(Assembled with O-Rings)<br />

For the ELAN 9000/6X00/5000/DRC-e. For use with the<br />

Corrosion-Resistant Torch and the<br />

Ryton Scott Spray Chamber.<br />

Part No. Each (€)<br />

Cassette Torch Injector Support Adapter<br />

For ELAN 9000/DRC-e. For use with the Corrosion-Resistant<br />

Torch and the Ryton Scott Spray Chamber. For cassette torch<br />

mounts (manufactured after April 2005).<br />

Part No. Each (€)<br />

Injector Support Adapter O-Ring Kit<br />

For ELAN 9000/6X00/5000/DRCs.<br />

Includes O-Rings for all Injector<br />

Support Adapters.<br />

Injector Support Adapter O-Rings<br />

WE023951 168<br />

For ELAN DRC II. Pass-through design for use with ball<br />

joint injectors. For use with cassette torch mounts<br />

(manufactured after April 2005).<br />

Part No. Each (€)<br />

W1012406 214<br />

For ELAN 9000/6X00/5000/DRC-e. For use with the<br />

Corrosion-Resistant Torch and the Ryton Scott Spray<br />

Chamber. For twist type torch mounts<br />

(manufactured before April 2005). Part No. Each (€)<br />

N8122007 62<br />

N8120116 79<br />

W1013266 214<br />

Part No.<br />

Each (€)<br />

N8120100 4<br />

Position Torch Type Part No. Each (€)<br />

External Twist/Cassette 09210011 1<br />

Internal Twist/Cassette 09210012 1<br />

External (Large) Cassette W1013545 4<br />

Sample Introduction Inductively Coupled Plasma – MS<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

195


Sample Introduction<br />

Nebulizers<br />

Concentric Nebulizers<br />

Concentric Teflon Nebulizer – PFA-ST<br />

Inductively Coupled Plasma – MS Sample Introduction<br />

Concentric Teflon Nebulizer – PFA-ST Part No. N8122192<br />

The PFA-ST Nebulizer features high purity, HF-resistance,<br />

and high performance, along with an exchangeable external<br />

sample uptake capillary. The sample uptake rate is controlled<br />

by the dimension of the external capillary or probe. For use<br />

with autosamplers. Requires a CTFE Union (N8122355) to<br />

connect to the UltraClean Autosampler Probe.<br />

All-Teflon construction, chemically inert<br />

Chemically resistant – ideal for strong acids, alkalis, organics<br />

Resistant to clogging – reliably self-aspirated or pumped<br />

Low, spike-free background for important elements<br />

such as Fe and Ca<br />

Produces a fine aerosol for high transport efficiency<br />

and high sensitivity<br />

Analyze all sample types with a single introduction system<br />

Direct analysis of volatile and non-volatile organic solvents<br />

External threaded interface designed for zero dead<br />

volume connections and easy maintenance<br />

Exchangeable uptake capillaries allow one nebulizer to be<br />

used at different self-aspiration rates from 100 to 400 μL/min.<br />

Can be pumped from<br />

Part No. Each (€)<br />

0.1 to 3 mL/min.<br />

N8122192 1849<br />

Teflon Sample Capillaries for PFA-ST Nebulizers<br />

PFA sample capillaries for use with PFA-ST nebulizer.<br />

Size Uptake Rate Part No. Each (€)<br />

0.5 mm i.d. 400 μL/min. N8122384 158<br />

0.25 mm i.d. 100 μL/min. N8122383 158<br />

Concentric Teflon Nebulizer – PFA-20<br />

UltraClean PFA Teflon nebulizer with<br />

20 μL/min. free aspiration uptake rate.<br />

Not for use with autosamplers.<br />

Part No.<br />

Each (€)<br />

N8122350 1913<br />

Concentric Teflon Nebulizer – PFA-100 Part No. N8122351<br />

Concentric Teflon Nebulizer – PFA-100<br />

UltraClean PFA Teflon Nebulizer with<br />

100 μL/min. free aspiration uptake rate.<br />

Not for use with autosamplers.<br />

MEINHARD Nebulizers<br />

Part No.<br />

The MEINHARD ® Concentric Nebulizer reflects exacting<br />

standards in design and manufacturing. Its advantages<br />

include simplicity of design and operation, reproducible<br />

and self-aligning aerosol, and close fabrication control.<br />

They provide excellent sensitivity and precision for aqueous<br />

solutions and samples with few dissolved solids (less than<br />

1%). MEINHARD Nebulizers are self-aspirating. Not to be<br />

used with solutions containing hydrofluoric acid. PerkinElmer<br />

offers three types for ICP-MS: MEINHARD C3, K, and A3.<br />

All MEINHARD Nebulizers require an End Cap (N0680504)<br />

for use with Ryton Scott Spray Chambers. The Type A3 is<br />

an all quartz concentric nebulizer and ships standard on the<br />

ELAN DRC/DRC plus /DRC II.<br />

MEINHARD Model Material Part No. Each (€)<br />

Type C3 Glass N8102011 867<br />

Type K Glass N0681574 918<br />

Type A3 Quartz WE024371 533<br />

Liquid Connector for Concentric Nebulizers<br />

Low dead volume PEEK connector for use with MEINHARD<br />

Concentric Nebulizers. Requires 0.062 in. (1.59 mm) o.d.<br />

tubing (WE024375). Standard on ELAN DRCs. Not required<br />

for PFA Teflon Nebulizers.<br />

Part No. Each (€)<br />

WE024372 110<br />

Teflon Sample Capillary for Concentric Nebulizers<br />

Each (€)<br />

N8122351 1849<br />

PFA sample capillary 0.062 o.d. x 0.020 i.d. in (1.59 x 0.5 mm)<br />

60 cm length. For use with the Liquid Connector for<br />

Concentric Nebulizers (WE024372). Standard on the<br />

ELAN DRC/DRC plus /DRC II.<br />

Part No. Each (€)<br />

WE024375 1<br />

196


Sample Introduction<br />

Nebulizers<br />

MicroMist Nebulizers<br />

The MicroMist micro-uptake glass concentric nebulizer offers<br />

high performance for limited sample volumes. MicroMists<br />

with sample uptakes 0.2 - 0.4 mL/min. are fitted with an<br />

EzyFit connector with 1.3 o.d. x 0.50 mm i.d. x 700 mm<br />

long sample tubing. MicroMists with sample uptakes<br />

0.05 - 0.1 mL/min. are fitted with an EzyFit connector<br />

with 1.3 o.d. x 0.25 mm i.d. x 700 mm long sample tubing.<br />

All MicroMist Nebulizers offered by PerkinElmer are<br />

supplied with the EzyLok Argon connector.<br />

MicroMist Nebulizer Part No. N0775342<br />

MicroMist Nebulizers with 1 L/min. Ar Flow<br />

Uptake Rate Part No. Each (€)<br />

0.4 mL/min. N0775341 590<br />

0.2 mL/min. N0775342 677<br />

0.1 mL/min. N0775343 677<br />

0.05 mL/min. N0775344 870<br />

SeaSpray Nebulizer<br />

The SeaSpray Concentric Nebulizer is ideal for samples with<br />

high dissolved solids and offers outstanding nebulization<br />

efficiency for trace level analysis. It offers freedom from<br />

clogging while nebulizing solutions near the limit of<br />

solubility of most mineral salts, and conferring significant<br />

sensitivity gains. The SeaSpray Nebulizer for use with the<br />

ELAN series allows an Ar Flow Rate up to 1 L/min. and an<br />

Uptake Rate up to 2 mL/min.<br />

The SeaSpray is supplied with an EZT-075 EzyFit connector<br />

(sample tube 0.75 i.d. x 1.3 mm o.d.). All SeaSpray Nebulizers<br />

offered by PerkinElmer are supplied<br />

with the EzyLok Argon connector. Part No. Each (€)<br />

SeaSpray Nebulizer Part No. N0775340<br />

PFA End-Cap<br />

Used to fit any Concentric Nebulizer<br />

onto the end of the 47 mm PFA<br />

Scott Spray Chamber.<br />

N0775340 750<br />

Part No.<br />

Each (€)<br />

N8122357 638<br />

Ryton End-Cap for Concentric Nebulizers<br />

Ryton End-Cap to fit any<br />

Concentric Nebulizer onto a<br />

Ryton ScottSpray Chamber.<br />

O-Rings for Concentric Nebulizer End Cap<br />

Size Part No. Each (€)<br />

Small 00473194 4<br />

Large 09902153 1<br />

GemClean<br />

Cross-Flow II Nebulizer<br />

GemClean Cross-Flow II Nebulizer<br />

Cross-Flow II Replacement GemTips<br />

Includes a Clear Sapphire<br />

Sample Tip and a Red Ruby<br />

Argon Tip optimized for ICP-<br />

MS. The tips are constructed of<br />

PEEK for maximum corrosion<br />

resistance. Used in all<br />

GemClean Cross-Flow II<br />

Nebulizers produced after<br />

September 1998. Not for use with Cross-Flow Nebulizers<br />

produced before September 1998.<br />

Part No. Each (€)<br />

Cross-Flow Replacement GemTips<br />

For use in all Cross-Flow Nebulizers produced before<br />

September 1998. Includes a Clear Sapphire Sample Tip and<br />

a Red Ruby Argon Tip. The tips are constructed of PEEK for<br />

maximum corrosion resistance. Not<br />

for use with Cross-Flow II Nebulizers. Part No. Each (€)<br />

N0580624 112<br />

Cross-Flow Nebulizer O-Ring Kit<br />

Complete set of O-Rings for use with<br />

Cross-Flow and Cross-Flow II Nebulizers.<br />

Cross-Flow II Nebulizer Argon Ferrule<br />

For use with Cross-Flow II<br />

Nebulizers only.<br />

Part No.<br />

Each (€)<br />

N0680504 261<br />

For ELAN DRC-e/9000/6X00/5000/500/250. Complete<br />

chemically inert Cross-Flow II Nebulizer Assembly for<br />

ICP-MS. Specially processed to reduce BEC levels below<br />

1 ppb. Contains a Ryton End-Cap with a GemTip Clear<br />

Sapphire Sample Tip and a GemTip Red Ruby Argon Tip<br />

optimized for ICP-MS.<br />

Part No. Each (€)<br />

N8120516 510<br />

N8120515 113<br />

Part No.<br />

Each (€)<br />

N9300067 33<br />

Part No.<br />

Each (€)<br />

09920515 9<br />

Sample Introduction Inductively Coupled Plasma – MS<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

197


Sample Introduction<br />

Nebulizers<br />

Inductively Coupled Plasma – MS Sample Introduction<br />

Cross-Flow II Nebulizer Sample Ferrule<br />

For use with Cross-Flow II<br />

Nebulizers only.<br />

Cross-Flow II Nebulizer Ferrule Kit<br />

Contains five Sample and<br />

five Argon Ferrules.<br />

End Cap for Cross-Flow II Nebulizer<br />

Contains only the Cross-Flow II End-Cap<br />

with no Fittings or Nebulizer Tips.<br />

GemClean Cross-Flow II<br />

Nebulizer Replacement Parts<br />

Part No.<br />

Each (€)<br />

N0680612 55<br />

Part No.<br />

Each (€)<br />

N8122239 201<br />

GemClean Cross-Flow II Ryton Nebulizer Assembly<br />

Shipped after September 1998.<br />

Components Part No. Each (€)<br />

1 1 Sample Ferrule - TBG 1/16 Tefzel 09920518 9<br />

2 Nut - TBG PEEK 09920516 19<br />

3 Nut 09920517 19<br />

4 Argon Ferrule - TBG 1/8 Tefzel 09920515 9<br />

5 O-Ring, 18W, 1 3/8 i.d., 1 5/8 o.d. 09902033 5<br />

6 Ring 00473543 28<br />

7 O-Rings (2) 09921045 1<br />

8<br />

0.126 i.d., 0.040 w.d., Viton<br />

End Cap Cross-Flow II Nebulizer N8122239 201<br />

9 GemTip Kit for Cross-Flow II Nebulizer N8120515 113<br />

(Contains one each: Argon and Sample tip)<br />

9a<br />

9b<br />

Red Ruby Nebulizer, Argon Tip<br />

Clear Nebulizer Sample Tip<br />

10 Screws (2) - Knurled 00473539 15<br />

10<br />

6<br />

5<br />

7<br />

1<br />

2<br />

8<br />

9b<br />

7<br />

Part No.<br />

10<br />

9a<br />

4<br />

Each (€)<br />

09920518 9<br />

3<br />

Microconcentric Nebulizers<br />

CETAC MCN-100 Microconcentric Nebulizer<br />

Operates at low-flow rates with efficiency that approaches<br />

50%. With flow rates of only 30 μL/min., it can provide<br />

detection limits of a pneumatic nebulizer operating at up<br />

to 1000 μL/min. Total analysis can be<br />

performed on small sample volumes.<br />

HF resistant, high solids capability.<br />

Part No.<br />

N0691702<br />

Each (€)<br />

975<br />

CETAC Aridus Desolvating Microconcentric Nebulizer<br />

For use in ICP-MS when polyatomic spectral interferences<br />

degrade detection limits for certain elements. By the use of<br />

a membrane desolvation system, matrix and solvent species<br />

are swept out of the sample line, never reaching the plasma.<br />

As a result, many polyatomics, like ArO and ArH, are<br />

dramatically reduced, enabling elements like Fe, Ca, and K<br />

to be determined under normal plasma conditions.<br />

Voltage Part No. Each (€)<br />

110 V N8122340 20300<br />

220 V N8122341 20300<br />

198


Sample Introduction<br />

Nebulizers and Peristaltic Pump Supplies and Accessories<br />

Ultrasonic Nebulizers<br />

CETAC Ultrasonic Nebulizer<br />

The Ultrasonic Nebulizer expands the analytical capacity<br />

of your ICP-MS instrument by increasing your sample<br />

introduction efficiency. With this increased efficiency, you<br />

can typically expect an improvement of detection limits<br />

by a factor of 10.<br />

The Ultrasonic Nebulizer uses mechanical forces from an<br />

oscillating transducer to break a liquid sample stream into<br />

very small droplets with a relatively uniform droplet size.<br />

Because the formation of this fine aerosol is so efficient, a<br />

desolvation system consisting of a heated tube and a<br />

condenser is placed after the nebulization chamber to<br />

remove most of the water.<br />

U-6000AT + Ultrasonic Nebulizer System<br />

The U-6000AT + adds a third desolvation stage (membrane<br />

desolvation) which effectively removes water vapor from<br />

the aerosol stream. This eliminates the principal source<br />

of oxygen and hydrogen from the ICP improving detection<br />

limits for elements such as Ca, Fe, and K by a factor of<br />

10 to 100 for ICP-MS.<br />

Organic Analysis by ICP-MS<br />

With the U-6000AT + , trace elements can be determined in<br />

most organic solvents. The aerosol introduced into the ICP-<br />

MS, is virtually free of volatile organic solvent. Trouble-free<br />

determinations of analytes dissolved in solvents such as<br />

kerosene, methanol, THF, n-MP, and IPA are accomplished.<br />

The U-6000AT + can be used with all PerkinElmer ICP and<br />

ICP-MS instruments. Includes one Ultrasonic Nebulizer and<br />

Cooling System.<br />

Voltage Part No. Each (€)<br />

115 V, 50/60 Hz N0691709 26400<br />

230 V, 50/60 Hz N0691710 26400<br />

U-5000AT + Ultrasonic Nebulizer System<br />

The U-5000AT + Ultrasonic Nebulizer offers enhanced<br />

detection limits (up to 10x and greater) for ICP-MS.<br />

Can be used with all PerkinElmer ICP-MS instruments.<br />

Includes one Ultrasonic Nebulizer with two stages of<br />

Peltier cooled desolvation.<br />

Voltage Part No. Each (€)<br />

115 V, 50/60 Hz N8120140 13800<br />

230 V, 50/60 Hz N8120141 13800<br />

Ultrasonic Nebulizer Accessories<br />

Description Part No. Each (€)<br />

Drain Pump Tubing and Connector Kit N8122150 183<br />

Transducer Assembly N8122161 933<br />

KALREZ ® O-Ring for Spray Chamber N8122162 561<br />

Gilson Peristaltic Pump<br />

and Accessories<br />

Gilson ® Minipulse 3, Four-Channel Peristaltic Pump<br />

For ELAN 6X00/5000. 230 V, 50/60 Hz.<br />

Interface Cable for Computer-Control of Gilson<br />

Minipulse 3 Peristaltic Pump<br />

For ELAN 6X00 series.<br />

Replacement Head for Gilson Minipulse 3,<br />

Four-Channel Peristaltic Pump<br />

A replacement head (only) for<br />

Gilson Four-Channel Peristaltic Pump.<br />

Peristaltic Pump Tubing<br />

Peristaltic Pump Tubing<br />

Part No.<br />

Peristaltic pump tubing comes in a package of 12,<br />

30 cm (1 foot) lengths, unless otherwise noted.<br />

Each (€)<br />

N8122126 3877<br />

Part No.<br />

Each (€)<br />

N8125003 759<br />

Part No.<br />

Each (€)<br />

N8122127 1709<br />

Dimensions Color Specifications Part No. Each (€)<br />

0.76 mm i.d. Black/ Standard PVC Peristaltic 09908587 59<br />

Black Pump Tubing, resistant to<br />

most mineral acids. Two stop.<br />

1.14 mm i.d.* Red PVC Tubing for 2 mL/min. N0680375 99<br />

flow rate. Two stop.<br />

3.16 mm i.d. Black/ Drain Tubing for Peristaltic N8122012 37<br />

White Pump. Two stop.<br />

2.79 mm i.d. Violet/ Solvent Flex Tubing, 02508080 37<br />

White Two stop. 1<br />

0.76 mm i.d. Black/ Solvent Flex Tubing, 00473550 59<br />

Black Two stop. 1<br />

1.14 mm i.d. Red Solvent Flex Tubing, N0680376 92<br />

Two stop.<br />

0.76 mm i.d. Black/ Silicone Manifold Tubing, 00473552 88<br />

Black for use with organic solvents,<br />

including MIBK. Two stop. 2<br />

2.79 mm i.d. Violet/ Silicone Manifold Tubing, 09923448 37<br />

White for use with organic solvents,<br />

including MIBK. Two stop. 2<br />

2.79 mm i.d. Violet/ Pharmed Drain Tubing for N8122252 126<br />

White Peristaltic Pump, for use<br />

with organic solvents. Two stop.<br />

* Includes 6 in. (152 mm) PTFE Tubing (09985708) to adapt 0.045 in.<br />

(1.14 mm) i.d. tubing to the Nebulizer Capillary Tubing (09908265).<br />

1<br />

Specially formulated PVC for use with Kerosene or Xylene.<br />

Not recommended for use with MIBK (Methyl Isobutyl Ketone).<br />

2<br />

Not recommended for use with Kerosene or Xylene.<br />

Sample Introduction Inductively Coupled Plasma – MS<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

199


Sample Introduction<br />

Sample Introduction Systems and Replacement Parts<br />

Inductively Coupled Plasma – MS Sample Introduction<br />

Organic Sampling Systems<br />

Peltier Cooled Organic Sample Introduction System<br />

Complete sample introduction system used for the<br />

determination of contaminant’s in light organic solvents<br />

and with HPLC speciation using organic mobile phases ><br />

5% MeOH. User selectable temperature settings of 2° and<br />

-5 °C. Consists of: Peltier-cooled Quartz Cyclonic Spray<br />

Chamber with Oxygen Port, PFA-ST Concentric Nebulizer,<br />

2.0 mm Quartz Injector, Pharmed Peristaltic Pump Tubing,<br />

Teflon Drain Tubing, Oxygen, and Make-up Gas Lines.<br />

110/220 V, 50/60 Hz.<br />

PC 3 Spray Chamber<br />

The PC 3 is the first Peltier-cooled quartz cyclonic spray<br />

chamber for ICP-MS and ICP-OES. The quartz cyclonic<br />

spray chamber offers the advantages of low-memory effects,<br />

fast rinse-out, and in many cases higher sample transport<br />

efficiency. The PC 3 cools the outer walls of the cyclonic<br />

spray chamber to a constant temperature. This reduces<br />

polyatomic ion interferences, such as oxides, for ICP-MS<br />

analysis. The PC 3 reduces solvent loading when volatile<br />

organic solvents are analyzed. Thermal stabilization of the<br />

spray chamber also enhances long-term stability for both<br />

ICP-MS and ICP-OES, particularly for laboratories where<br />

room temperature is not constant.<br />

A PFA Nebulizer is used to introduce samples to the PC 3 .<br />

The nebulizer attaches to the O-Ring Free Cyclonic Spray<br />

Chamber using a one-piece Teflon PFA ferrule-nut.<br />

Torch Type Part No. Each (€)<br />

Cassette Torch Mount N8122410 3714<br />

Twist Type Torch Mount N8122389 3714<br />

PC 3 Spray Chamber, included in the Peltier Cooled Organic<br />

Sample Introduction System Part No. N8122389<br />

Heavy Organic Sample Introduction System<br />

For the ELAN 9000/6X00/5000/DRCs, requires but does not<br />

include, a Heavy Organics Chiller. This accessory is a complete<br />

sample introduction system used for the determination of<br />

contaminant’s in organic solvents that range in volatility from<br />

acetone to kerosene. Recommended for use with heavy<br />

organics that have low oxygen content. Consists of: Glass<br />

Water-cooled Scott Spray Chamber, Glass Concentric<br />

Nebulizer, Ryton End-Cap, 0.85 mm i.d. Alumina Injector,<br />

Viton Peristaltic Pump Tubing, Organic Waste Container,<br />

all necessary connecting hardware, and tubing.<br />

Many organic solutions with low oxygen content will<br />

require the addition of a small amount of oxygen, into the<br />

plasma. Platinum Sampler and Skimmer Cones should<br />

always be used whenever oxygen is added to the plasma.<br />

When used with the ELAN 9000/6X00 series, the Mass Flow<br />

Controller Assembly for Organic Sampling Systems (N8120161)<br />

is required, but not included.<br />

The ELAN DRC/DRC plus requires the Mass Flow Controller<br />

Assembly for Organic Sampling Systems (N8120161), the<br />

Injector Support Adapter for ELAN 9000/6X00/5000/DRC-e<br />

(Twist Type-N8122007 or Cassette Type-W1013266), and<br />

Retaining Ring for ELAN DRC-e/9000/ 6X00/5000 (WE014081).<br />

The ELAN DRC II requires the Oxygen Gas Mass Flow<br />

Controller Upgrade Kit (WE028428), the Injector Support<br />

Adapter for ELAN 9000/6X00/5000/DRC-e (Twist Type-<br />

N8122007 or Cassette Type-W1013266),<br />

and Retaining Ring for ELAN<br />

Part No. Each (€)<br />

DRC-e/9000/6X00/5000 (WE014081).<br />

N8122132 7100<br />

Organic Sampling System Consumables Kit<br />

For the ELAN 9000/6X00/5000/DRCs. Included with the<br />

Heavy Organic Sample Introduction System (N8122132).<br />

Contains tubing for oxygen inlet,<br />

peristaltic pump tubing, and O-rings. Part No. Each (€)<br />

Sample Introduction Systems<br />

PFA Teflon Sample Introduction Systems<br />

Designed for use with either a Cassette or a Twist Type<br />

Torch Mount. Consists of a 47 mm PFA Scott Spray<br />

Chamber (N8122356), PFA End-Cap (N8122357) with<br />

two PFA-100 Concentric Nebulizers (N8122351), either a<br />

Sapphire or a Platinum Injector in PFA support (see table<br />

below), and a Demountable Quartz Torch (N8122006).<br />

Torch Type Injector Type Part No. Each (€)<br />

Cassette Torch Mount Sapphire 1.8 mm i.d. N8122414 6000<br />

Cassette Torch Mount Platinum 2.0 mm i.d. N8122415 7100<br />

Twist Type Torch Mount Sapphire 1.8 mm i.d. N8122362 6000<br />

Twist Type Torch Mount Platinum 2.0 mm i.d. N8122363 7100<br />

HF-Resistant Sample Introduction<br />

System for Cassette Torch<br />

N8122118 1116<br />

For use with ELAN DRC IIs (manufactured after April<br />

2005). Consists of a Ryton Scott Spray Chamber (N8120124)<br />

with a GemClean Cross-Flow II Nebulizer (N8120516), a 2<br />

mm i.d. Alumina Injector (N8126041), Injector Support<br />

Adapter with O-Rings (N8120116),<br />

Retaining Ring (WE014081), and Part No. Each (€)<br />

Drain Connector (WE013119).<br />

WE024782 2117<br />

200


Sample Introduction<br />

Sample Introduction Systems and Replacement Parts<br />

Replacement Parts for Twist Type Torch Models<br />

Twist Type Torch Replacement Parts<br />

for the ELAN 9000/6X00/5000<br />

For ELAN 9000/6X00/5000s manufactured before April 2005.<br />

3<br />

Components Part No. Each (€)<br />

6<br />

1 Ryton Scott Spray Chamber N8120124 402<br />

12<br />

Large O-Ring WE013060 1<br />

for Ryton Scott Spray Chamber<br />

13<br />

Retaining Ring WE014081 59<br />

14<br />

Right-Angled Drain Connector WE013119 230<br />

15<br />

External O-Ring 09210012 1<br />

for Injector Support Adapter<br />

16<br />

Internal O-Ring 09210011 1<br />

for Injector Support Adapter<br />

17<br />

Injector Support Adapter N8122007 62<br />

for ELAN 9000/6X00/5000<br />

18<br />

GemClean Cross-Flow II Nebulizer N8120516 510<br />

Twist Type Torch Replacement Parts for the ELAN DRC<br />

For ELAN DRCs manufactured before April 2005.<br />

Components Part No. Each (€)<br />

E3 9 Safety Shield/Clamp Assembly W1020996 214<br />

10 E2 Baffled Quartz Cyclonic Spray Chamber WE025221 898<br />

11 E3 MEINHARD Type A3 WE024371 533<br />

All-Quartz Concentric Nebulizer<br />

12 E1 Liquid Connector WE024372 110<br />

for Concentric Nebulizers<br />

13 E1 Retaining Ring WE025239 57<br />

for Baffled Quartz<br />

Cyclonic Spray Chamber<br />

14 E1 Ball Joint Injector Support Adapter WE023951 168<br />

for ELAN DRCs<br />

5<br />

ELAN 9000/6X00/5000<br />

5<br />

13<br />

ELAN DRC<br />

14<br />

6<br />

7<br />

10<br />

8<br />

9<br />

2<br />

11<br />

1<br />

12<br />

4<br />

Sample Introduction Inductively Coupled Plasma – MS<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

201


Sample Introduction<br />

Spray Chambers<br />

Baffled Cyclonic Spray Chambers<br />

Water-Cooled Baffled Glass Cyclonic Spray Chamber<br />

for ELAN DRC/DRC plus /DRC II<br />

The Water-Cooled design permits the introduction of<br />

coolant for temperature control. Thermostatting to constant<br />

temperature helps ensure highly reproducible results and<br />

long term stability. Can also be cooled to suppress<br />

volatilization, allowing the direct aspiration of highly<br />

volatile solvents such as naphtha and petrol/gasoline.<br />

Inductively Coupled Plasma – MS Sample Introduction<br />

The spray chamber is an integral part of the sample<br />

introduction system responsible for filtering the sample<br />

mist to permit the appropriate droplet size distribution to<br />

reach the plasma.<br />

The Baffled Cyclonic Spray Chamber features a central<br />

transfer tube which acts as a secondary particle separator<br />

helping separate larger aerosol particles from the sample. This<br />

reduces solvent load in the plasma without compromising<br />

detection limits.<br />

The distance between the bottom of the baffle and the<br />

chamber wall is carefully controlled so that droplets cannot<br />

form on the bottom of the baffle. The advantage is smooth<br />

draining and improved precision.<br />

Baffled Quartz Cyclonic Spray Chamber<br />

For ELAN DRC/DRC plus /DRC II.<br />

Baffled Quartz Spray Chamber<br />

(Teflon O-ring type) with ball joint.<br />

Safety Shield/Clamp Assembly<br />

for the Baffled Quartz Spray Chamber<br />

Polypropylene safety shield/clamp assembly for the Baffled<br />

Quartz Cyclonic Spray Chamber<br />

(WE025221) used on ELAN<br />

DRC/DRC plus /DRC II.<br />

Part No.<br />

W1020996<br />

Each (€)<br />

214<br />

O-Ring for Baffled Quartz Cyclonic Spray Chamber<br />

Teflon coated Viton. Standard on<br />

Baffled Quartz Cyclonic Spray<br />

Chamber (WE025221).<br />

Retaining Ring for the Baffled<br />

Quartz Cyclonic Spray Chamber<br />

Baffled Quartz Cyclonic<br />

Spray Camber<br />

Part No. WE025221<br />

Part No.<br />

Each (€)<br />

WE025221 898<br />

Part No.<br />

Each (€)<br />

09210011 1<br />

Retaining ring for use with the Baffled Quartz Cyclonic Spray<br />

Chamber (WE025221) used on the ELAN DRC/DRC plus /DRC II.<br />

Not for Ryton Scott Spray Chambers.<br />

Torch Type Part No. Each (€)<br />

Cassette Torch Mount W1020331 71<br />

Twist Type Torch Mount WE025239 57<br />

The Water-Cooled Cyclonic Spray Chamber with oxygen<br />

port and ball joint connection is designed for use with the<br />

ELAN DRC/ DRC plus /DRC II. Glass with<br />

baffle. Recommended for light organic<br />

solvents and chromatography use.<br />

Part No.<br />

N8120181<br />

Each (€)<br />

1339<br />

Water-Cooled Baffled Glass Cyclonic Spray Chamber<br />

Water-Cooled Cyclonic Spray Chamber with oxygen port and<br />

ball joint connection for use with the ELAN DRC-e/9000/<br />

6X00/5000. Glass with baffle. Recommended for light organic<br />

solvents and chromatography use. Requires, but does not<br />

include, Cyclonic Spray Chamber<br />

Mount (WE014034) for first time use. Part No. Each (€)<br />

Water-Cooled O-Ring Free<br />

Baffled Glass Cyclonic Spray Chamber<br />

Water-Cooled O-Ring Free Cyclonic<br />

Spray Chamber for use with the<br />

ELAN DRC-e/9000/6X00/5000.<br />

The O-Ring Free design eliminates<br />

the O-Ring seal between the<br />

nebulizer and the spray chamber.<br />

It has several important features:<br />

Simple nebulizer insertion and removal<br />

No O-Rings to replace<br />

Smooth lock and release mechanism<br />

Faster washout times due to elimination of dead<br />

volume around the nebulizer seal<br />

Positive stop to ensure your nebulizer<br />

is correctly positioned every time<br />

Part No.<br />

N0775353<br />

Each (€)<br />

1340<br />

Cyclonic Spray Chamber Mount<br />

N8120180 1339<br />

Mounting hardware for use with the Water-cooled Baffled<br />

Cyclonic Spray Chamber (N8120180), the Cyclonic Spray<br />

Chamber (N8122188), or the Water-Cooled O-Ring Free<br />

Baffled Cyclonic Spray Chamber (N0775353) on the<br />

ELAN DRCe/9000/6X00/5000.<br />

Part No. Each (€)<br />

WE014034 191<br />

202


Sample Introduction<br />

Spray Chambers<br />

Cyclonic Spray Chamber<br />

The cyclonic spray chamber<br />

relies on momentum to<br />

efficiently and quickly<br />

remove the larger droplets<br />

from the sample mist<br />

decreasing any opportunity<br />

for occlusion or agglomeration<br />

of the smaller droplets. The<br />

result is higher efficiency,<br />

better precision, and faster<br />

washouts than other spray<br />

chamber designs.<br />

Save time and expense<br />

O-Ring Free Cyclonic Spray Chamber<br />

Part No. N0775350<br />

1. Decreased sample introduction system installation and<br />

optimization time due to the preset nature of the spray<br />

chamber/nebulizer combination<br />

2. More samples per hour due to minimal dead volume<br />

and efficient draining<br />

Unique design characteristics<br />

1. The nebulizer port is oversized so that sample solution<br />

cannot build up around the nebulizer as it will in other<br />

cyclonic designs. This translates to less carryover,<br />

faster washout times, and greater productivity from<br />

your Optima<br />

2. The nebulizer port angle is tightly controlled so that the<br />

nebulizer mist impacts on the same chamber wall area<br />

in each and every spray chamber. The angle of incidence<br />

is critical in determining the efficiency of large<br />

droplet removal<br />

3. A trace metal free plastic nebulizer Adapter is employed<br />

to fix the depth of nebulizer insertion at the optimal<br />

position. Because of this, there is no need for an operator<br />

to move the nebulizer in and out of the port in an effort<br />

to locate the “sweet spot”<br />

4. Each spray chamber incorporates a precisely machined<br />

ridge along the inside top of the spray chamber. Both the<br />

angle and depth of the ridge are critical to performance.<br />

The result is efficient draining of sample waste and the<br />

elimination of large droplets being swept into the plasma.<br />

This eliminates the periodic “spiking” that adversely<br />

affects precision and fosters faster washout times<br />

Glass Cyclonic Spray Chamber Kit<br />

For use with the ELAN DRCe/9000/6X00/5000. Kit contains<br />

one Glass Cyclonic Spray Chamber, mounting hardware and<br />

instructions. Requires, but does not<br />

include, a Concentric Nebulizer. Not<br />

for use with ELAN DRC/DRC plus /DRC II.<br />

Part No.<br />

N8120150<br />

Each (€)<br />

976<br />

Glass Cyclonic Spray Chamber<br />

For use with the ELAN DRCe/9000/6X00/5000. Glass<br />

Cyclonic Spray Chamber only. Not for use with ELAN<br />

DRC/DRC plus /DRC II. Does not include the mounting hardware<br />

that is included in the Cyclonic Spray<br />

Chamber Kit (N8120150).<br />

Part No. Each (€)<br />

O-Ring Free Glass Cyclonic Spray Chamber<br />

For use with the ELAN DRCe/9000/ 6X00/5000. O-Ring<br />

Free Glass Cyclonic Spray Chamber only. Not for use with<br />

ELAN DRC/DRC plus /DRC II.<br />

Part No. Each (€)<br />

Water-Cooled O-Ring Free Glass<br />

Cyclonic Spray Chamber<br />

N8122188 606<br />

N0775350 584<br />

O-Ring Free Glass Cyclonic<br />

Spray Chamber only. Ball<br />

joint type. For use with the<br />

ELAN DRC/DRC plus /DRC II.<br />

Part No.<br />

Each (€)<br />

N0775354 1260<br />

Sample Introduction Inductively Coupled Plasma – MS<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

203


Sample Introduction<br />

Spray Chambers<br />

Drain Components<br />

Scott Spray Chamber<br />

Inductively Coupled Plasma – MS Sample Introduction<br />

Right-Angled Drain Connector<br />

Teflon connector used to connect Drain<br />

Tubing to Ryton Scott Spray Chamber.<br />

Drain Bottle<br />

For ELAN 9000/6X00/DRC series.<br />

Drain Bottle Cap Assembly<br />

For ELAN 9000/6X00/DRC series.<br />

Drain Adapter<br />

For ELAN 9000/6X00/DRC series.<br />

PFA Teflon Spray Chamber<br />

PFA Teflon Scott Spray Chamber<br />

UltraClean, low volume 47 mm Scott Spray Chamber.<br />

For use with concentric nebulizers.<br />

PFA Teflon construction<br />

Low contamination<br />

Chemically inert<br />

Ideal for dilute-and-shoot analysis<br />

O-ring-free seal reduces contamination<br />

Easy to clean, low maintenance<br />

High transmission and selectivity<br />

Requires a PFA Injector Assembly<br />

and the PFA End-Cap (N8122357).<br />

PFA End-Cap<br />

Used to fit a Concentric Nebulizer<br />

onto the end of the 47 mm PFA Scott<br />

Spray Chamber.<br />

Part No.<br />

Each (€)<br />

WE013119 230<br />

Part No.<br />

Each (€)<br />

09904991 112<br />

Part No.<br />

Each (€)<br />

N0690271 398<br />

Part No.<br />

Each (€)<br />

09920379 1<br />

Part No.<br />

Each (€)<br />

N8122356 1148<br />

Part No.<br />

Each (€)<br />

N8122357 638<br />

Water-Cooled Glass Scott Spray Chamber<br />

For ELAN DRC-e/9000/6X00/5000. Water-cooled Glass<br />

Scott Spray Chamber included in Heavy Organics Sample<br />

Introduction System (N8122132). Recommended for use<br />

with heavy organic solvents.<br />

Does not include End-Cap.<br />

Part No. Each (€)<br />

Ryton Scott Spray Chamber<br />

For ELAN 9000/6X00/5000. Complete HF-resistant Ryton<br />

Scott Spray Chamber. Includes (1) Large O-Ring (WE013060),<br />

(1) Retaining Ring (WE014081),<br />

and (1) Right-Angled Drain<br />

Connector (WE013119).<br />

Part No.<br />

N8120124<br />

Each (€)<br />

402<br />

Large O-Ring for the Ryton Scott Spray Chamber<br />

For use with the HF-resistant Ryton<br />

Scott Spray Chamber on the<br />

ELAN DRC-e/9000/6X00/5000.<br />

Retaining Ring for the Ryton Scott Spray Chamber<br />

For use with the HF-resistant Ryton<br />

Scott Spray Chamber on the<br />

ELAN DRC-e/9000/6X00/5000.<br />

PFA Teflon Scott Spray Chamber Part No. N8122356<br />

PFA End-Cap Part No. N8122357<br />

WE013829 4508<br />

Part No.<br />

Each (€)<br />

WE013060 1<br />

Part No.<br />

Each (€)<br />

WE014081 59<br />

204


Sample Introduction<br />

Torches and Torch Accessories<br />

RF Coils<br />

RF Coil Assembly for the ELAN 9000/6X00/DRCs<br />

Includes fittings, self-aligning.<br />

RF Coil Assembly for the ELAN 5000<br />

Self-aligning.<br />

Torch Alignment Tool<br />

For ELAN 9000/6X00/DRCs. Used<br />

to align the torch in the load coil.<br />

Power Amplifier Tube (Ceramic)<br />

For ELAN 9000/6X00/DRCs and<br />

ELAN 5000As manufactured<br />

after September 1992.<br />

Torches<br />

Demountable Quartz Torch<br />

For all ELANs.<br />

High Efficiency Demountable Quartz Torch<br />

For ELAN 9000/6X00/DRCs. Demountable quartz torch only.<br />

Operates at 25% reduced Argon gas flows compared to the<br />

Demountable Quartz Torch (N8122006). The ELAN 9000<br />

and 6X00 require the High Efficiency Torch Kit (W1007468)<br />

for first time installation.<br />

Part No. Each (€)<br />

High Efficiency Torch Kit<br />

Includes the High Efficiency Torch<br />

(W1008384) and flow restrictors required<br />

for use with the ELAN 9000 and 6X00.<br />

Cassette Torch Mount<br />

Part No.<br />

Part No.<br />

W1008384 377<br />

Part No.<br />

Each (€)<br />

WE021816 312<br />

Part No.<br />

Each (€)<br />

WE012411 249<br />

Part No.<br />

Each (€)<br />

WE015554 97<br />

Part No.<br />

Each (€)<br />

N0695477 2571<br />

Each (€)<br />

N8122006 287<br />

Each (€)<br />

W1007468 631<br />

The Cassette Torch Mount is a new, innovative torch design,<br />

introduced in April 2005, that is fully modular, demountable,<br />

rugged and easy to maintain. Now changing torch components<br />

is a simple process – no tools are required. Cassette Torch<br />

Mount does not include Demountable Quartz Torch or<br />

Injector (shown at the right).<br />

ELAN Model Part No. Each (€)<br />

DRC II W1020672 3698<br />

9000 W1020668 3698<br />

Teflon Ferrules<br />

For torch gas connectors.<br />

Description Part No. Each (€)<br />

Front Ferrule 09903119 4<br />

Back Ferrule 09903120 4<br />

Cassette Torch Replacement Parts<br />

Components Part No. Each (€)<br />

11<br />

Injector Nut W1012408 57<br />

12<br />

Injector Spacer W1012409 14<br />

13<br />

Internal O-Ring 09210011 1<br />

for Injector Support Adapter<br />

14<br />

Torch Spacer W1012410 26<br />

15<br />

Large External O-Ring W1013545 4<br />

for Injector Support Adapter<br />

16<br />

External O-Ring 09210012 1<br />

7<br />

for Injector Support Adapter<br />

Cassette Torch Injector Support W1013266 214<br />

Adapter for ELAN 9000/DRC-e<br />

18<br />

Ball Joint Cassette Torch Injector W1012406 214<br />

Support Adapter for ELAN DRC II<br />

19<br />

Cassette Torch Retaining Ring W1020331 71<br />

110<br />

Safety Shield/Clamp Assembly W1020996 214<br />

2<br />

1<br />

4<br />

3<br />

5 6<br />

Cassette Torch Mount Part No. W1020672<br />

9<br />

10<br />

7 For ELAN 9000/DRC-e<br />

8 For DRC II<br />

Sample Introduction Inductively Coupled Plasma – MS<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

205


ICP-MS Software<br />

ICP-MS Operating System and Application Software<br />

ELAN Software<br />

Inductively Coupled Plasma – MS ICP-MS Software<br />

ELAN 3.3 Software for ELAN 9000/6X00/DRCs<br />

Utilizing the powerful Windows ® XP operating system,<br />

the simple, intuitive software makes ICP-MS accessible to<br />

novices and experts alike. The software is designed<br />

specifically for ICP-MS and includes helpful guidelines that<br />

assist users in selecting the best mass for their particular<br />

matrices. Priority samples, flexible quality-control checks,<br />

transient signal handling, speciation analysis, runlist build,<br />

and customizable reporting are just a few of the features<br />

that will make your life easier (Figure 1). Integrated<br />

maintenance videos and our new PathFinder HTML-based<br />

Help system take the guesswork out of routine tasks. The<br />

SmartTune software wizard automatically sets up all your<br />

tuning procedures, runs them in the sequence you select,<br />

and reports the results based on user-selected pass/fail<br />

criteria. The software includes a library of standard reports<br />

and provides the flexibility to customize reports for your<br />

methods, without having to use a complicated macro<br />

language or exit to another program. The powerful ELAN<br />

software provides effortless operation, all day, every day.<br />

Figure 1: The Build Run List feature will automatically build an exact listing of<br />

all your standards, quality-control checks and samples before you start your<br />

automated analysis – eliminating unexpected sample-run orders and errors.<br />

Upgrade to ELAN 3.3 for use with Chromera Speciation<br />

software. Chromera Speciation software requires<br />

Windows XP SP2.<br />

ELAN 3.3 requires Windows 2000 Pro SP3 or<br />

Windows XP Pro SP2. Service installation not included.<br />

Part No.<br />

Each (€)<br />

W1015115 630<br />

ELAN 3.2 Enhanced Security Software<br />

for ELAN 9000/6X00/DRCs<br />

ELAN Enhanced Security (ES) is an optional software<br />

package that gives you the security, data integrity, and<br />

traceability tools needed to develop FDA-compliant standard<br />

operating procedures, whether you are in a research or<br />

manufacturing environment. User authenticity is verified<br />

by ELAN ES software to ensure that access is limited to<br />

authorized individuals and permissions to perform specific<br />

tasks are controlled. All raw data, including methods and<br />

parameters used, are stored in an encrypted, checksumprotected<br />

dataset, in order to guard against data tampering.<br />

Audit trails that capture file, system, and security-related<br />

events provide traceability to most software actions.<br />

ELAN ES software offers the following features:<br />

Data archival tools simplify long-term data storage<br />

User authenticity is verified by ELAN ES to ensure<br />

access is limited to authorized individuals<br />

File changes are “stamped” with user ID, user name,<br />

date/time, and description<br />

Checksum ensures data tampering is detected<br />

ELAN ES software provides ultimate security for<br />

the regulated environment:<br />

Controlled access to ELAN ES application<br />

Customizable security-feature configuration<br />

Controlled permissions to perform certain operations<br />

ELAN 3.2 ES requires<br />

Windows XP Professional SP2.<br />

Instrument Remote Control Kit<br />

for ELAN 9000/6X00/DRCs<br />

Part No.<br />

Each (€)<br />

W1013691 6600<br />

Contains software and analog modem to control ELAN<br />

9000/6X00/DRC series instruments from a remote location.<br />

For use with analog telephone lines only – not for ISDN.<br />

Requires a second computer (not included). Service<br />

installation required.<br />

Part No. Each (€)<br />

09410047 580<br />

206


Speciation by Chromatography<br />

Speciation Supplies<br />

Chromera Speciation Software<br />

Chromera Speciation Module for ICP-MS<br />

Quantitation, integration, peak identification, and reporting<br />

software for elemental speciation on the ELAN 9000/6X00/<br />

DRC series of instruments to HPLC systems. Chromera<br />

provides fully integrated control of PerkinElmer Series 200<br />

HPLC systems. Includes computerized switching valve and<br />

read cable. Requires Windows XP Pro<br />

SP2 and ELAN 3.3 software. Service Part No. Each (€)<br />

installation not included.<br />

N8120191 4206<br />

TotalChrom ICP-MS to Chromera Upgrade<br />

Requires existing TotalChrom license. Includes Chromera<br />

speciation module and ELAN 3.3 software. Service<br />

installation not included.<br />

Part No. Each (€)<br />

HPLC Columns for Speciation<br />

Bromine Speciation in Drinking Water<br />

INTENSITY (CPS)<br />

1200<br />

1000<br />

800<br />

600<br />

400<br />

200<br />

0<br />

CHROMATOGRAPHIC CONDITIONS<br />

Sample Type: Drinking Water<br />

Column: 5 μm x 15 cm Anion Exchange PRP-X100<br />

Species: Br - , Br0 3<br />

-<br />

Run Time: 7 minutes<br />

Notes: PEEK Hardware.<br />

Part No.<br />

0 100 200 300 400<br />

TIME (SECONDS)<br />

N8122253<br />

N8120192 2055<br />

BrO 3<br />

-<br />

Arsenic and Chromium Speciation in Drinking Water<br />

PULSE INTENSITY<br />

8000<br />

7000<br />

6000<br />

5000<br />

4000<br />

3000<br />

2000<br />

1000<br />

0<br />

As +3 As+5 Cr +6<br />

0 100 200<br />

TIME (SECONDS)<br />

CHROMATOGRAPHIC CONDITIONS<br />

Sample Type: Drinking Water<br />

Column: 3 μm x 3 cm Reduced Activity C8 Cartridge<br />

Species: As +3 , As +5 , Cr +3 , Cr +6<br />

Run Time: < 3 minutes<br />

Notes: Package of 5. Requires Column Holder (07150013) for first time use.<br />

Part No. 02580191<br />

Cr +3<br />

Arsenic Speciation in Urine<br />

Br - As +3<br />

AsB<br />

DMA<br />

As +5<br />

0 1 2 3 4 5 6 7 8 9 10<br />

TIME (SECONDS)<br />

CHROMATOGRAPHIC CONDITIONS<br />

Sample Type: Urine<br />

Column: 5 μm x 15 cm Anion Exchange PRP-X100<br />

Species: As +3 , As +5 , AsB, MMA, DMA<br />

Run Time: 9 minutes<br />

Notes: PEEK Hardware<br />

Part No.<br />

N8122253<br />

MMA<br />

Speciation by Chromatography Inductively Coupled Plasma – MS<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

207


Speciation by Chromatography<br />

Speciation Supplies<br />

Inductively Coupled Plasma – MS Speciation by Chromatography<br />

Guard Column Kit for As Speciation<br />

PRP-X100 Anion Exchange Guard Column Kit for As<br />

speciation. PEEK. Contains one column holder and two<br />

cartridges. For use with HPLC 3 μm<br />

column for As speciation (N8122256).<br />

Part No. Each (€)<br />

N8122254 226<br />

HPLC 3 μm Column for As Speciation<br />

3 μm x 15 cm PRP-X100 Anion Exchange Column for<br />

As speciation. PEEK hardware.<br />

For use with the CDC protocol for<br />

As speciation.<br />

Part No.<br />

N8122256<br />

Each (€)<br />

843<br />

HPLC Column Holder.<br />

For use with 3 cm columns.<br />

Speciation Accessories and Supplies<br />

Peltier Cooled Autosampler Tray for Series 200<br />

Peltier Controller for Autosampler Tray<br />

For use with Peltier Cooled Autosampler Tray (N2930035).<br />

Included in the Supplemental<br />

Arsenic Speciation Kit (N8120534). Part No. Each (€)<br />

Six-Port Switching Valve<br />

Two position PEEK switching valve for injecting internal<br />

standards or connection to ICP-MS. Internal port diameter<br />

0.38 mm (0.015"). Manual or RS232 control. Included with<br />

Chromera. 110/240 V, 50/60 Hz<br />

Part No. Each (€)<br />

HPLC Cable for ELAN 9000/6X00/DRCs<br />

To interface a Series 200 HPLC to the<br />

ELAN. With external stop function –<br />

requires v3.0 software for external stop.<br />

Part No.<br />

N2930035 1454<br />

N2930036 1849<br />

N8122251 1348<br />

Part No.<br />

Each (€)<br />

07150013 190<br />

100-position 2 mL vial tray. Temperature control from<br />

4-60 °C ± 1 °C. Requires Peltier Controller (N2930036).<br />

Included in the Supplemental<br />

Arsenic Speciation Kit (N8120534). Part No. Each (€)<br />

Each (€)<br />

W1007493 150<br />

Tubing Adapter<br />

Polypropylene Sample Vials<br />

0.6 mL Vial (pkg. 500) for use with<br />

Series 200 HPLC Autosampler.<br />

Not for Cr speciation.<br />

PEEK Solvent Filter<br />

PEEK In-Line Filter<br />

For filtering LC mobile phase<br />

after pump, 10 μm size.<br />

Speciation Kits<br />

Connects Peristaltic<br />

Pump Tubing used in<br />

ICP-MS to PEEK Tubing<br />

used in LC, for use<br />

in speciation.<br />

For filtering LC mobile<br />

phase, 10 μm size.<br />

Standard Flow LC-ICP-MS Interface Kit<br />

For connecting HPLC systems operating at flow rate<br />

> 0.5 mL/min. to the ELAN 9000/DRC-e. Includes a Glass<br />

Concentric Nebulizer, Spray Chamber,<br />

PEEK tubing, and fittings.<br />

Part No. Each (€)<br />

Supplemental Arsenic Speciation Kit<br />

Part No.<br />

Each (€)<br />

N8122258 29<br />

Part No.<br />

Each (€)<br />

N9302130 172<br />

Part No.<br />

Each (€)<br />

N8122249 33<br />

Part No.<br />

Each (€)<br />

N8122250 33<br />

N8120532 1071<br />

For labs who wish to use the CDC protocol for As speciation.<br />

Includes Peltier Cooled Autosampler Tray (N2930035), Peltier<br />

Controller (N2930036), HPLC 3 μm Column for As Speciation<br />

(N8122256), Guard Column, Six-port Switching Valve<br />

(N8122251), PEEK fittings, Solvent<br />

Bottle Tray, and 20 μL PEEK Sample Part No. Each (€)<br />

Loop. Requires HPLC system.<br />

N8120534 3100<br />

208


Standards<br />

PerkinElmer Pure Standards for ICP-MS<br />

Depend on Genuine<br />

PerkinElmer Pure Standards<br />

Whatever Your Application,<br />

You Can Count on PerkinElmer<br />

Pure Standards to Yield Reliable,<br />

Accurate Results<br />

PerkinElmer offers a wide selection of standards for ICP-MS.<br />

Each solution is supplied with a comprehensive Certificate<br />

of Analysis that documents the quality. To ensure that your<br />

measurements are accurate, you can rely on our certificates<br />

to provide complete information.<br />

PerkinElmer Pure Atomic Spectroscopy Standards are manufactured<br />

for PerkinElmer to the highest quality standards.<br />

Quality<br />

PerkinElmer Pure standards are prepared<br />

gravimetrically from high-purity metals<br />

and salts, using high-purity reagents.<br />

■ ASTM Type I, filtered water minimizes cations,<br />

anions, and colloids; resistivity is maintained in<br />

the 18-megohm range.<br />

■ Acids used are the highest purity.<br />

■ Semi-micro analytical balances and Class A volumetric<br />

glassware are used, and the bottles are subjected to a<br />

stringent leaching/cleaning process.<br />

■ Following preparation, standards are analyzed<br />

for the major element as well as trace impurities.<br />

The results of the analysis are provided on the<br />

Certificate of Analysis.<br />

Reliability<br />

Multi-element standards are measured<br />

by three methods:<br />

1. Complete analysis (wet and ICP)<br />

of the starting materials<br />

2. Wet and ICP analysis of the<br />

individual prepared standards<br />

3. ICP-MS check of the final multi-element standard<br />

The results of these three analyses are<br />

reported on the Certificate of Analysis.<br />

NIST or NBS SRMs used for the ICP<br />

check are also reported on the<br />

Certificate of Analysis.<br />

Safety<br />

We ship standards to comply with both<br />

DOT and IATA regulations to ensure<br />

their safe delivery to you.<br />

Features<br />

■ ISO 9001 accredited by Underwriters Laboratories<br />

including comprehensive continuous improvement,<br />

product recall, corrective action request, and other<br />

quality maintenance and improvement programs<br />

■ Accreditation by NVLAP/NIST as an EPA performance<br />

testing provider<br />

■ Product labeling meets OSHA and California<br />

labeling standards<br />

■ Bottles are low-density polyethylene from industry<br />

standard Nalge Corporation and are pre-leached and<br />

pre-treated for increased product stability and purity<br />

■ High-purity acids and ASTM Type I water used in<br />

all manufacturing, as reported on the Certificate<br />

of Analysis<br />

■ Traceability directly to NIST standard reference<br />

materials, not independent sources or secondary<br />

NIST SRMs and reported on the Certificate<br />

of Analysis<br />

■ Wet assays on all multi-element products via<br />

standard, accepted wet methods and traceable<br />

directly to NIST SRM to +/-0.5% of true value<br />

and reported on the Certificate of Analysis<br />

■ All solutions tested and confirmed for the absence<br />

of interfering anions, e.g. chloride, bromide, etc.<br />

■ Twelve months guaranteed stability +/-0.5% for<br />

all major analytes for all products<br />

209


Standards<br />

PerkinElmer Pure Plus Standards for ICP-MS<br />

Inductively Coupled Plasma – MS Standards<br />

Detection Limit Standards<br />

ELAN DRC Sensitivity/Detection Limit Solution<br />

For use with ELAN DRC/DRC plus /DRC II. Not for use with the<br />

ELAN DRC-e.<br />

Matrix/Vol. Concentration of Element Part No. Each (€)<br />

0.5% HNO 3 /250 mL 1 μg/L Barium N8125034 63<br />

1 μg/L Beryllium<br />

1 μg/L Calcium<br />

1 μg/L Cerium<br />

1 μg/L Cobalt<br />

1 μg/L Indium<br />

1 μg/L Iron<br />

1 μg/L Lead<br />

1 μg/L Magnesium<br />

1 μg/L Potassium<br />

1 μg/L Rhodium<br />

1 μg/L Sodium<br />

1 μg/L Uranium<br />

ELAN 6100 Detection Limit Solution<br />

For use with the ELAN 9000/6100/DRC-e.<br />

Matrix/Vol. Concentration of Element Part No. Each (€)<br />

1% HNO 3 /250 mL 10 μg/L Beryllium N8125031 63<br />

10 μg/L Cobalt<br />

10 μg/L Indium<br />

10 μg/L Uranium<br />

ELAN 5000 Detection Limit Solution<br />

Matrix/Vol. Concentration of Element Part No. Each (€)<br />

2% HNO 3 /100 mL 10 μg/L Beryllium N8122017 63<br />

10 μg/L Cobalt<br />

10 μg/L Germanium<br />

10 μg/L Indium<br />

10 μg/L Thallium<br />

10 μg/L Uranium<br />

Instrument Calibration Standards<br />

ELAN DRC/DRC plus /DRC II Solution Kit<br />

A complete set of setup, test, and calibration standards<br />

for ELAN DRCs.<br />

Includes: Part No. Each (€)<br />

2 x 1000 mL of Setup/Stability/Masscal Solution N8125035 89<br />

2 x 250 mL of Wash Solution N8125033 37<br />

1 x 250 mL of Sensitivity/Detection Limit Solution N8125034 63<br />

1 x 100 mL of Methanol Blank Solution N8125037 60<br />

1 x 100 mL of Chromium in Methanol Solution N8125038 60<br />

Part No.<br />

Each (€)<br />

N8120541 318<br />

ELAN DRC Setup/Stability/Masscal Solution<br />

For use with ELAN DRC/DRC plus /DRC II. Not for use with the<br />

ELAN DRC-e.<br />

Matrix/Vol. Concentration of Element Part No. Each (€)<br />

0.5% HNO 3 /1000 mL 1 μg/L Aluminum N8125035 89<br />

10 μg/L Barium<br />

1 μg/L Cadmium<br />

1 μg/L Cerium<br />

1 μg/L Chromium<br />

1 μg/L Copper<br />

1 μg/L Indium<br />

1 μg/L Lead<br />

1 μg/L Magnesium<br />

1 μg/L Manganese<br />

1 μg/L Rhodium<br />

1 μg/L Thorium<br />

ELAN 9000/6100 Solution Kit<br />

For use with the ELAN 9000/6100. A complete set of setup,<br />

test, and calibration standards.<br />

Includes: Part No. Each (€)<br />

2 x 1000 mL of Setup/Stability/Masscal Solution N8125030 63<br />

1 x 125 mL of Dual-Detector Calibration Solution N8125032 50<br />

1 x 500 mL of Wash Solution N8122038 45<br />

1 x 250 mL of Detection Limit Solution N8125031 63<br />

ELAN 9000/6100 Setup/Stability/Masscal Solution<br />

For use with the ELAN 9000/6100/DRC-e.<br />

Matrix/Vol. Concentration of Element Part No. Each (€)<br />

1% HNO 3 /1000 mL 10 μg/L Barium N8125030 63<br />

10 μg/L Cadmium<br />

10 μg/L Cerium<br />

10 μg/L Copper<br />

10 μg/L Indium<br />

10 μg/L Lead<br />

10 μg/L Magnesium<br />

10 μg/L Rhodium<br />

10 μg/L Uranium<br />

ELAN 9000/6X00 Dual-Detector Calibration Solution<br />

For use with the ELAN 9000/6100/DRC-e.<br />

Part No.<br />

Each (€)<br />

N8120522 292<br />

Matrix/Vol. Concentration of Element Part No. Each (€)<br />

1% HNO 3 /100 mL 200 μg/L Cadmium N8125032 50<br />

200 μg/L Copper<br />

200 μg/L Lead<br />

200 μg/L Magnesium<br />

200 μg/L Rhodium<br />

210


Standards<br />

PerkinElmer Pure Plus Standards for ICP-MS<br />

ELAN 6000/5000 Plasma Setup Solution<br />

Multi-Element Calibration Standard 3<br />

Matrix/Vol. Concentration of Element Part No. Each (€)<br />

2% HNO 3 /1000 mL 10 μg/L Barium N8122014 88<br />

10 μg/L Cadmium<br />

10 μg/L Cerium<br />

10 μg/L Copper<br />

10 μg/L Germanium<br />

10 μg/L Lead<br />

10 μg/L Magnesium<br />

10 μg/L Rhodium<br />

10 μg/L Scandium<br />

10 μg/L Terbium<br />

10 μg/L Thallium<br />

Multi-Element Standards<br />

Designed to contain virtually every element in the mass<br />

spectrum for concentration checks.<br />

Multi-Element Calibration Standard 1<br />

Matrix/Vol. Concentration of Element Part No. Each (€)<br />

2% HNO 3 /100 mL 10 μg/mL Beryllium N9300231 152<br />

10 μg/mL Bismuth<br />

10 μg/mL Cerium<br />

10 μg/mL Cobalt<br />

10 μg/mL Indium<br />

10 μg/mL Lead<br />

10 μg/mL Magnesium<br />

10 μg/mL Nickel<br />

10 μg/mL Uranium<br />

Multi-Element Calibration Standard 2<br />

Matrix/Vol. Concentration of Element Part No. Each (€)<br />

5% HNO 3 /100 mL 10 μg/mL Cerium N9300232 254<br />

10 μg/mL Dysprosium<br />

10 μg/mL Erbium<br />

10 μg/mL Europium<br />

10 μg/mL Gadolinium<br />

10 μg/mL Holmium<br />

10 μg/mL Lanthanum<br />

10 μg/mL Lutetium<br />

10 μg/mL Neodymium<br />

10 μg/mL Praseodymium<br />

10 μg/mL Samarium<br />

10 μg/mL Scandium<br />

10 μg/mL Terbium<br />

10 μg/mL Thorium<br />

10 μg/mL Thulium<br />

10 μg/mL Ytterbium<br />

10 μg/mL Yttrium<br />

Matrix/Vol. Concentration of Element Part No. Each (€)<br />

5% HNO 3 /100 mL 10 μg/mL Aluminum N9300233 381<br />

10 μg/mL Arsenic<br />

10 μg/mL Barium<br />

10 μg/mL Beryllium<br />

10 μg/mL Bismuth<br />

10 μg/mL Cadmium<br />

10 μg/mL Calcium<br />

10 μg/mL Cesium<br />

10 μg/mL Chromium<br />

10 μg/mL Cobalt<br />

10 μg/mL Copper<br />

10 μg/mL Gallium<br />

10 μg/mL Indium<br />

10 μg/mL Iron<br />

10 μg/mL Lead<br />

10 μg/mL Lithium<br />

10 μg/mL Magnesium<br />

10 μg/mL Manganese<br />

10 μg/mL Mercury**<br />

10 μg/mL Nickel<br />

10 μg/mL Potassium<br />

10 μg/mL Rubidium<br />

10 μg/mL Selenium<br />

10 μg/mL Silver<br />

10 μg/mL Sodium<br />

10 μg/mL Strontium<br />

10 μg/mL Thallium<br />

10 μg/mL Uranium<br />

10 μg/mL Vanadium<br />

10 μg/mL Zinc<br />

** Mercury is supplied as a separate solution due to incompatibility<br />

with other elements.<br />

Multi-Element Calibration Standard 3 –<br />

Without Mercury<br />

Contains all the of the elements found in the standard<br />

Multi-Element Calibration Standard 3, excluding Mercury.<br />

Matrix/Vol. Part No. Each (€)<br />

5% HNO3/100 mL N9301720 343<br />

Multi-Element Calibration Standard 4<br />

Matrix/Vol. Concentration of Element Part No. Each (€)<br />

10% HCL /100 mL 10 μg/mL Antimony N9300234 165<br />

10 μg/mL Gold<br />

10 μg/mL Hafnium<br />

10 μg/mL Iridium<br />

10 μg/mL Palladium<br />

10 μg/mL Platinum<br />

10 μg/mL Rhodium<br />

10 μg/mL Ruthenium<br />

10 μg/mL Tellurium<br />

10 μg/mL Tin<br />

Standards Inductively Coupled Plasma – MS<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

211


Standards<br />

PerkinElmer Pure Plus Standards for ICP-MS<br />

Inductively Coupled Plasma – MS Standards<br />

Multi-Element Calibration Standard 5<br />

Matrix/Vol. Concentration of Element Part No. Each (€)<br />

H 2 O with trace 10 μg/mL Boron N9300235 228<br />

of HF /100 mL 10 μg/mL Germanium<br />

10 μg/mL Molybdenum<br />

10 μg/mL Niobium<br />

10 μg/mL Phosphorus<br />

10 μg/mL Rhenium<br />

10 μg/mL Silicon<br />

10 μg/mL Sulfur<br />

10 μg/mL Tantalum<br />

10 μg/mL Titanium<br />

10 μg/mL Tungsten<br />

10 μg/mL Zirconium<br />

Performance Verification Standards<br />

Methanol Blank Solution<br />

For DRC mode performance verification.<br />

Matrix/Vol. Part No. Each (€)<br />

1% Semiconductor Grade/100 mL N8125037 60<br />

Chromium in Methanol Solution<br />

For DRC mode performance verification.<br />

Matrix/Vol. Concentration of Element Part No. Each (€)<br />

1% Semiconductor 10 μg/L Chromium N8125038 60<br />

Grade Methanol/<br />

100 mL<br />

Selenium Solution<br />

For use with DRC-e.<br />

Matrix/Vol. Concentration of Element Part No. Each (€)<br />

5% HNO 3 /250 mL 10 μg/L Selenium N8125039 86<br />

Smart Tune Standards<br />

SmartTune Solution for Standard ELANs/DRC-e<br />

Matrix/Vol. Concentration of Element Part No. Each (€)<br />

1% HNO 3 /1000 mL 10 μg/L Barium N8125040 90<br />

10 μg/L Beryllium<br />

10 μg/L Cerium<br />

10 μg/L Cobalt<br />

10 μg/L Indium<br />

10 μg/L Magnesium<br />

10 μg/L Lead<br />

10 μg/L Rhodium<br />

10 μg/L Uranium<br />

SmartTune Solution for DRC/DRC plus /DRC II<br />

Matrix/Vol. Concentration of Element Part No. Each (€)<br />

0.5% HNO 3 /1000 mL 10 μg/L Barium N8125041 90<br />

1 μg/L Beryllium<br />

1 μg/L Cerium<br />

1 μg/L Cobalt<br />

1 μg/L Indium<br />

1 μg/L Iron<br />

1 μg/L Lead<br />

1 μg/L Magnesium<br />

1 μg/L Thorium<br />

1 μg/L Uranium<br />

Wash Standards<br />

ELAN DRC Wash Solution<br />

Matrix/Vol. Part No. Each (€)<br />

0.5% HNO 3 /250 mL N8125033 37<br />

ELAN 9000/6X00/DRC-e Wash Solution<br />

Not for use with ELAN DRC/DRC plus /DRC II.<br />

Matrix/Vol. Part No. Each (€)<br />

1% HNO 3 /500 mL N8122038 45<br />

212


PerkinElmer is the acknowledged global leader in Inductively<br />

Coupled Plasma Optical Emission Spectroscopy (ICP-OES),<br />

helping you advance research and development, control<br />

product quality and improve the environment.<br />

The PerkinElmer ® Optima family of ICP-OES instruments<br />

is recognized worldwide as the preferred choice to solve your<br />

application requirements. Whether your requirements are for<br />

high performance and productivity or high performance and<br />

analytical flexibility, the Optima family can meet your needs.<br />

And each instrument is backed by the renowned service and<br />

support of PerkinElmer.<br />

Inductively Coupled Plasma – OES


Inductively Coupled Plasma – OES<br />

QUICK-FIND INDEX Page #<br />

Air and Gas Accessories 216<br />

Blower and Vent Assembly 217<br />

Baffled Cyclonic Spray<br />

Chambers 225<br />

Concentric Nebulizers 221<br />

Cooling Systems/Chillers 217<br />

Cyclonic Spray Chambers 225<br />

Demountable Quartz Torches 227<br />

GemCone Nebulizers 222<br />

GemTip Crossflow II Nebulizers 223<br />

Injector Support Adapters 220<br />

Injectors 220<br />

Peristaltic Pump Tubing 224<br />

Quick-Change Torch Modules 227<br />

RF Load Coils 219<br />

Ryton Scott Spray Chambers 226<br />

Standards 231<br />

Torch Replacement Parts 228<br />

Ultrasonic Nebulizers 221<br />

PerkinElmer offers a wide selection of superior quality products designed to work with<br />

your PerkinElmer instruments. Our precision-designed products deliver the peace of<br />

mind that comes from knowing that you’ll get the results you need.<br />

The Quick Find Index to the left will help you find products fast. For your convenience,<br />

products are alphabetized by category, sub-category, and family. There is also a more<br />

complete Alphabetical INDEX on page 429 and a Part Number INDEX on page 407.<br />

Demountable Quartz Torches<br />

Cooling Systems/Chillers<br />

Nebulizers<br />

PerkinElmer’s demountable design uses one piece of quartz<br />

tubing for plasma and auxiliary gas flow. They are available<br />

in a range of styles from 0-3 Slots, depending on your<br />

instrument and application needs. From organic solvents<br />

to aqueous solutions, there is a torch designed to meet<br />

your need.<br />

Page 227<br />

Water Cooling Systems (Chillers) provide clean, reliable<br />

temperature controlled fluid for open tanks or closed loop<br />

cooling. They are ideal for many routine process cooling<br />

needs. They feature convenient “one-touch” temperature<br />

control, bright LED readouts and audible and visual alarms.<br />

Page 217<br />

PerkinElmer offers a wide selection of nebulizers for use<br />

with your Optima. From our exclusive GemCone and GemTip<br />

Crossflow II designs to standard concentric and ultrasonic<br />

nebulizers, you can choose the option that best fits your<br />

instrument and your analysis.<br />

Page 221<br />

Spray Chambers<br />

The spray chamber is responsible for filtering the sample<br />

mist to permit the appropriate droplet size distribution to<br />

reach the plasma. PerkinElmer offers a large selection of<br />

Cyclonic, Baffled Cyclonic and Ryton Scott models. Cyclonic<br />

and Baffled Cyclonic models are available in Standard,<br />

O-Ring Free and HF Resistant versions.<br />

Page 225


The Optima Family Offers the<br />

Performance and Productivity<br />

to Meet Your Application Requirements<br />

The difference is in the design.<br />

Optima 5300 DV<br />

Building on the success of the<br />

Optima TM , the world’s most<br />

popular ICP family:<br />

■ CCD array detectors provide fast<br />

and accurate performance<br />

■ High-resolution spectrometers<br />

provide easier method development<br />

and greater accuracy<br />

■ Exceptional reliability with a integrated<br />

solid-state RF generator<br />

■ Patented Dual-view optical system<br />

ensures the widest working range<br />

■ Stabilized optical systems eliminate<br />

peak profiling and searching, ensuring<br />

exceptional long-term stability<br />

■ Enhanced sample throughput and<br />

performance with simultaneous<br />

background correction<br />

■ Superior optics, excellent RF stability,<br />

and a thermostatted sample<br />

compartment make it easy to meet<br />

U.S. E.P.A. and DIN regulations<br />

■ A full line of sampling accessories<br />

There has never been a better<br />

time to achieve greater ICP-OES<br />

productivity and performance.<br />

Select from the models below<br />

to choose the Optima that is<br />

right for your needs.<br />

Optima 2100 DV<br />

With the performance and reliability<br />

found in simultaneous systems and the<br />

flexibility inherent to conventional ICPs,<br />

the Optima 2100 DV is revolutionizing<br />

ICP Optical Emission Spectrometry. The<br />

Optima 2100 DV Charge-coupled Device<br />

(CCD) ICP system brings advanced<br />

technology to the entry level ICP market.<br />

The Optima 2100 DV is the ideal solution<br />

for research and quality assurance<br />

laboratories that have a wide variety of<br />

samples and lower frequency of analysis.<br />

Features:<br />

■ CCD detector allows you to collect a complete<br />

simultaneous analyte spectrum at speeds that<br />

far exceed conventional systems<br />

■ Outstanding spectrometer design for superior<br />

results, detection limits and precision<br />

■ Eliminates the need for inaccurate analyte peak<br />

search routines and slow, multiple background reads<br />

■ Automatic dual viewing (DV) ensures the lowest<br />

detection limits and the widest working ranges.<br />

Optima 5X00 DV Series<br />

The Optima 5X00 DV ICP-OES offers<br />

the performance required to maximize<br />

productivity. While other simultaneous<br />

ICPs claim “speed”, only the Optima<br />

5X00 DV Series has the optimized design<br />

required to ensure accuracy, improve<br />

method development, and consistently<br />

deliver the correct answer. The system is<br />

ideal for laboratories with moderate to<br />

heavy loads of difficult samples.<br />

Features:<br />

■ Enhanced real-time graphics and FIAS control<br />

allows transient measurements<br />

■ The SCD detector provides fast and<br />

accurate performance<br />

■ Exclusive high-resolution mode provides easier<br />

method development and greater accuracy<br />

■ Exceptional reliability with a second-generation<br />

integrated solid-state RF generator<br />

■ Thermostatted optical system eliminates peak profiling<br />

and searching, ensuring exceptional long-term stability<br />

Optima 5300V<br />

The Optima 5300V offers a classic vertical<br />

torch configuration that minimizes salt<br />

and carbon build-up, thus minimizing<br />

maintenance worries. This new<br />

application-focused Optima system is<br />

designed specifically to meet the needs<br />

of oil analysis programs and metallurgical<br />

and geological laboratories. The robust<br />

sample introduction system, with its<br />

efficient sample transport, makes<br />

analyzing these samples fast and easy.<br />

The 5300V can meet the challenges for<br />

the most demanding samples requiring<br />

high precision and accuracy.<br />

Features:<br />

■ Easy access to the sample introduction system<br />

■ The oils unit is supplied with a glass cyclonic spray<br />

chamber and a low-flow GemCone nebulizer. It is<br />

also supplied with a 1.2 mm Alumina injector.<br />

■ The HF resistant unit is supplied with a PEEK cyclonic<br />

spray chamber and a high-flow, HF resistant GemCone<br />

nebulizer. This unit is supplied with a standard 2.0 mm<br />

Alumina injector.<br />

215


Accessories for ICP–OES<br />

Autosampler, FIAS, and FIMS Supplies and Laboratory Products<br />

Autosampler, FIAS, and FIMS Supplies and Accessories for ICP-OES<br />

Please see pages 8-10 for our full selection of Autosampler Sample Trays, Sample Vessels, Probes, Tubing, and Accessories.<br />

Please see pages 21-28 for our full selection of Supplies and Accessories for FIAS and FIMS.<br />

Accessories for ICP–OES<br />

Air and Gas Accessories<br />

Air and Water Filters<br />

Description ICP Model Part No. Each (€)<br />

Air Filter Assembly for the Instrument Air Supply Optima TM 2X00/4X00/5X00 N0770198 459<br />

Air Filter and Regulator Kit for the Instrument Air Supply Optima 3X00 XL/3X00 DV 00470652 555<br />

includes Type A82 Balston Air Filter Gas Regulator, and Fittings<br />

Filter Element for the Pre-Final Filter Optima 2X00/3X00/4X00/5X00 09907122 12<br />

for Optima Axial and Dual-View Systems, for the Shear Gas<br />

Filter Element for the Final Filter Optima 2X00/3X00/4X00/5X00 09923464 19<br />

for Optima Axial and Dual-View Systems, for the Shear Gas<br />

Filter Cartridge Element for Type A82 Balston Air Filter – Optima 2X00/3X00/4X00/5X00 N0582251 42<br />

includes Argon and Nitrogen Filters<br />

Air Filter for the Fan of the Main Power Supply Optima 2X00/3X00/4X00/5X00 09995098 7<br />

Air Filter for the RF Generator Inlet Optima 2X00/4X00/5X00 N0775220 20<br />

Air Filter for the RF Generator Inlet Optima 3X00 02509115 7<br />

Water Filter Optima 2X00/3X00/4X00/5X00 09904845 191<br />

Cartridge for the Water Filter Optima 2X00/3X00/4X00/5X00 09904846 43<br />

Inductively Coupled Plasma – OES<br />

Air Compressors<br />

Delivers 50 L/min. at 4.2 bar. Mounted on a 38 L tank built<br />

to ASME high-strength specifications.<br />

Power Requirement Part No. Each (€)<br />

115 V, 60 Hz 03030313 1194<br />

230 V, 50 Hz 03030314 1135<br />

Neon Correction System Assembly<br />

Includes complete neon replacement<br />

assembly for the Optima 2X00.<br />

Nitrogen Purge<br />

Gas Generator<br />

Part No. N0695470<br />

Part No.<br />

Each (€)<br />

B0810144 2762<br />

Nitrogen Purge Gas Generators<br />

Recommended as a source of high purity nitrogen purge<br />

gas. Nitrogen is separated from ambient air by a patented<br />

pressure swing adsorption process using a carbon molecular<br />

sieve (CMS) to differentially adsorb oxygen, carbon dioxide,<br />

water vapor, etc.<br />

Purity 99.99%<br />

Flow rate 5.0 L/min.<br />

Delivery Pressure 5 Bar (73 psig)<br />

Max. ambient temperature: 45 °C<br />

Min. ambient temperature: 5 °C<br />

Power<br />

Built-in<br />

Requirement Air Compressor Part No. Each (€)<br />

115 V, 60 Hz Yes N0695470<br />

115 V, 60 Hz No N0695468<br />

220 V, 50 Hz Yes N0695471 15800<br />

220 V, 50 Hz No N0695469 13800<br />

Accessories for the Nitrogen Purge Gas Generator<br />

Description Part No. Each (€)<br />

Filter, Air Compressor Inlet (pkg. 10) N0695472 54<br />

Filter Kit, Air N0695473 121<br />

Service Kit, Air Compressor N0695475 689<br />

Silencer, Exhaust N0695474 28<br />

216


Accessories for ICP–OES<br />

Laboratory Products<br />

Blower and Vent Assembly<br />

Cooling Systems<br />

Chillers/Recirculating Water Cooling Systems<br />

Water Cooling Systems (Chillers) provide clean, reliable<br />

temperature controlled fluid for open tanks or closed<br />

loop cooling. These Cooling Systems are ideal for many<br />

routine process cooling needs. They feature convenient<br />

“one-touch” temperature control and bright LED readouts<br />

which can be easily read, even from across the room – and<br />

let you check temperature set point and fluid flow rate<br />

and/or pressure quickly.<br />

For added operational safety, they also feature audible<br />

and visual alarms that alert you instantly when operating<br />

parameters exceed pre-set limits. There are even user<br />

adjustable high and low temperature limits to help prevent<br />

unauthorized set point changes plus built-in safeties to alert<br />

you to low fluid levels and thermal runaway.<br />

Other features include a calibration function that allows<br />

you to adjust the Chiller’s temperature display to match<br />

a traceable temperature standard and optional interfaces<br />

for various control functions, such as on/off and<br />

remote control.<br />

Chiller Coolant Mix<br />

Blower and Vent Assembly<br />

A venting system is required to<br />

remove fumes and vapors from the<br />

torch of ICP emission spectrometers.<br />

A vent is recommended for use<br />

over the power supply unit of<br />

most ICP spectrometers for<br />

removal of dissipated heat.<br />

Use exhaust venting to:<br />

Protect lab personnel from toxic vapors<br />

Protect your instrument from corrosive vapors<br />

Improve stability of the ICP torch<br />

Includes Exhaust Hood (03031910), Adapter (03031911),<br />

and Blower. Does not include ducting.<br />

PerkinElmer Service Engineers are<br />

not permitted to install this unit.<br />

Part No.<br />

03030406<br />

Each (€)<br />

1218<br />

Non-glycol coolant, which is made up of five 1/2 gallon<br />

bottles of distilled water and includes an additive to control<br />

black algae and other resistant strains.<br />

Part No. Each (€)<br />

N0776099 264<br />

Exhaust Hood<br />

Stainless steel. Part of Blower<br />

and Vent Assembly (03030406).<br />

Flexible Gas Hosing<br />

100 mm i.d. x 3 m hosing<br />

for RF generator exhaust vent.<br />

Fresh Air Kit<br />

Kit to attach generator air to<br />

fresh air services. Includes<br />

adapter, hose, and clamp.<br />

Part No.<br />

Part No.<br />

Each (€)<br />

N0691578 50<br />

Part No.<br />

Each (€)<br />

03031910 236<br />

Each (€)<br />

N0770434 459<br />

ICP Model Power Requirement Operating Temp. Flow Rate Part No. Each (€)<br />

Optima 2X00/4X00/5X00 208-230 V, 60 Hz, 8 A -15˚ to 40 ˚C 60 psi: 4.3 gpm/16.3 Lpm N0772026 4029<br />

Optima 2X00/4X00/5X00 240 V, 50 Hz, 8.5 A -15˚ to 40 ˚C 60 psi: 4.3 gpm/16.3 Lpm N0772025 4029<br />

Optima 3X00 120 V, 60 Hz, 13.1 A -5˚ to 40 ˚C 60 psi: 1 gpm/3.8 Lpm N0691883 3558<br />

Optima 3X00 240 V, 50 Hz, 7.3 A -5˚ to 40 ˚C 60 psi: 1 gpm/3.8 Lpm N0691884 3558<br />

Accessories for ICP-OES Inductively Coupled Plasma – OES<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

217


Sample Introduction<br />

Accessories for Sample Introduction<br />

Drain Assembly Components<br />

Drain Adapter Assembly<br />

Assembly includes the Ryton Scott Spray Chamber fitting<br />

and tubing to pump out the waste solution from the spray<br />

chamber. Assembly does not include peristaltic pump tubing.<br />

ICP Model Part No. Each (€)<br />

Protective and<br />

Cleaning Accessories<br />

Inductively Coupled Plasma – OES Sample Introduction<br />

Optima 2X00/4X00/5X00 N0680504 261<br />

Optima 3000/3000 SCR/3X00 RL N0690287 308<br />

Optima 3X00 DV/XL/3000 SCX N0690288 51<br />

Drain Assembly Accessories<br />

Description Part No. Each (€)<br />

15 Liter Carboy 09904991 112<br />

Drain Assembly Hardware for the Plasma 400 00473449 87<br />

Drain Cap Assembly for all Optima Series N0690271 398<br />

Elbow Drain Assembly for the 3X00 XL 09920262 3<br />

Drain Loop Assembly for the Plasma 400<br />

Dimensions Solutions Part No. Each (€)<br />

18 in. Aqueous Only 00470551 344<br />

30 in. Organic or Aqueous 00470608 344<br />

Drain Tubing for the Plasma 400<br />

Dimensions Color Solutions Part No. Each (€)<br />

9.5 mm i.d. x 12.7 mm o.d. Clear Aqueous 02506519 3<br />

9.5 mm i.d. x 12.7 mm o.d. Yellow Organic 02506532 3<br />

Pumped Drain Accessory for the Plasma 400<br />

Uses the extra channel of the peristaltic<br />

pump to pump the waste solution out<br />

of the spray chamber.<br />

Part No.<br />

Each (€)<br />

N0650230 402<br />

Argon Humidifier with Bypass Part No. N0775331<br />

Argon Humidifier with Bypass<br />

The Argon Humidifier is commonly used in ICP analyses<br />

of samples with very high dissolved solids concentration.<br />

Helping to prevent salt build-up inside the sample introduction<br />

system, the Argon Humidifier allows uninterrupted<br />

and maintenance-free operation. The Argon Humidifier<br />

combines ease of operation, high performance and safety.<br />

For use with Optima 2X00/4X00/5X00.<br />

The rugged and durable plastic casing enhances safety<br />

The built-in pressure indicator serves as a diagnostic so<br />

you will always know the sample introduction system is<br />

operating properly<br />

An easy-to-use bypass toggle allows you to take the Argon<br />

Humidifier off-line without disconnecting argon lines<br />

Maximum and minimum fill marks ensure that you are<br />

always operating under optimum conditions<br />

A rugged bubbling frit ensures maximum saturation<br />

of the argon<br />

Part No. Each (€)<br />

N0775331 2046<br />

218


Sample Introduction<br />

Accessories for Sample Introduction<br />

Eluo Nebulizer Cleaner<br />

Particle build-up in a nebulizer capillary and tip causes<br />

sample flow to be constricted, thereby reducing nebulizer<br />

efficiency and performance. Previously there was no simple<br />

way to effectively clean and unblock nebulizers. Now,<br />

blocked nebulizers can be safely and easily restored to<br />

optimum performance with a revolutionary new cleaning<br />

instrument – the Eluo. The Eluo is designed to efficiently<br />

deliver a cleanser through the nebulizer capillary to<br />

dislodge particle build-up and thoroughly clean<br />

the nebulizer.<br />

Cleaning your nebulizer is now a simple three step process:<br />

1. Fill your Eluo with Methanol.<br />

2. Insert your nebulizer, tip first, into the Eluo.<br />

3. Clean your nebulizer by pressing the Plunger down.<br />

Use the Eluo regularly to maintain nebulizer performance<br />

and prolong nebulizer life. The Eluo is effective for<br />

MEINHARD ® , MicroMist, and SeaSpray nebulizers.<br />

Sample Compartment Drip Tray,<br />

Optima 3000 and Optima 3000 XL<br />

An acid resistant drip tray that fits in<br />

the bottom of the sample compartment.<br />

Sample Shelf Liner<br />

An acid resistant tray that lines the<br />

sample shelf of the Optima 3000<br />

and Optima 3000 XL.<br />

Thermal Shield for Sample<br />

Compartment Optima 3000<br />

A thermal shield that separates<br />

the nebulizer and spray chamber<br />

from the plasma torch.<br />

Purge Components<br />

Ceramic Interface Cone<br />

The Ceramic Interface Cone for the Optima 3X00 XL and<br />

3000 SCX includes the Ceramic Cone, the Purge<br />

Window (09992731), and the clamp.<br />

The Ceramic Cone is used between<br />

the plasma and the spectrometer.<br />

Part No.<br />

N0690666<br />

Each (€)<br />

268<br />

Ceramic Purge Extension<br />

For the Optima 3000/3000 SCR/<br />

3X00 RL/4300V/5300V.<br />

Part No.<br />

Part No.<br />

Part No.<br />

Part No.<br />

Each (€)<br />

N0695233 52<br />

Each (€)<br />

N0691182 159<br />

Each (€)<br />

N0695219 69<br />

Part No.<br />

Each (€)<br />

N0775358 277<br />

Each (€)<br />

N0581455 459<br />

Purge Extension Windows<br />

The Axial View Purge Extension Window is a replaceable<br />

quartz window that slides into the purge extension between<br />

the torch and the optics. The Radial View Purge Extension<br />

Window Tube is a replaceable quartz tube that slides into the<br />

mount between the torch and the optics for the radial view.<br />

ICP Model View Part No. Each (€)<br />

Optima 2X00 Radial B0810377 429<br />

Optima 2X00/3X00 XL/3000 SCX Axial 09992731 77<br />

Optima 3000/3000 SCR/3X00 RL/ Radial N0581497 159<br />

4300V/5300V<br />

Optima 3X00 DV Axial B0066549 21<br />

Optima 3X00 DV (long tube) Radial N0691689 223<br />

Optima 3X00 DV (short tube) Radial N0690672 217<br />

Optima 4X00/5X00 Axial N0771116 59<br />

Optima 4X00DV/5X00DV Radial N0770322 185<br />

Plasma 400 Radial N0681234 281<br />

B1<br />

B2<br />

RF Load Coils<br />

RF Load Coils*<br />

Components Part No. Each (€)<br />

Radial Purge Extension Window for N0581497 159<br />

Optima 3000/3000 SCR/3X00<br />

RL/4300V5300V<br />

Ceramic Purge Extension for Optima N0581455 459<br />

3000/3000 SCR/3X00 RL/4300V<br />

5300V<br />

ICP Model Part No. Each (€)<br />

Optima 2X00/4X00/5X00 DV N0775300 346<br />

Optima 3X00 XL/3X00 DV N0690772 242<br />

Optima 3000/3000 SCR/3X00 RL N0690572 204<br />

(For instruments manufactured BEFORE 9/21/94)<br />

Optima 3000/3000 SCR/3X00 RL N0690668 495<br />

(For instruments manufactured AFTER 9/21/94)<br />

Optima 4300V/5300V N0771536 178<br />

Plasma 400 (Assembly includes Torch Bonnet) N0680212 255<br />

* Installation by PerkinElmer Service is required, but not included.<br />

RF Load Coil Accessories<br />

Description Part No. Each (€)<br />

Igniter Spark Gap Assembly N0680275 111<br />

for Type II Demountable Torch<br />

Nylon Igniter Standoff 09989859 1<br />

B1<br />

B2<br />

Sample Introduction Inductively Coupled Plasma – OES<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

219


Sample Introduction<br />

Injectors and Adapters<br />

Injectors<br />

Injector Support Adapters<br />

Inductively Coupled Plasma – OES Sample Introduction<br />

Alumina Injectors<br />

Alumina injectors are corrosion-resistant to all mineral acids<br />

including HF and aqua regia. They are also used with less<br />

volatile organic solvents, e.g., xylene. The 2.0 mm i.d.<br />

Alumina Injector is shipped standard with all PerkinElmer<br />

ICP-OES instruments. A variety of sizes are available as an<br />

alternative to the standard injector.<br />

ICP Model Dimensions Part No. Each (€)<br />

Optima 2X00/4X00/5X00 DV 0.80 mm i.d. N0775227 204<br />

Optima 2X00/4X00/5X00 DV 1.2 mm i.d. N0775228 204<br />

Optima 2X00/4X00/5X00 DV 2.0 mm i.d. N0775177 204<br />

Optima 3000/3000 SCR/ 0.85 mm i.d. N0582186 159<br />

3X00 RL/Plasma 400/400 WMA<br />

Optima 3000/3000 SCR/ 1.5 mm i.d. N0582185 159<br />

3X00 RL/Plasma 400/400 WMA<br />

Optima 3000/3000 SCR/ 2.0 mm i.d. N0582184 159<br />

3X00 RL/Plasma 400/400 WMA<br />

Optima 3X00 XL/3X00 DV/ 2.0 mm i.d. N0695362 166<br />

3000 SCX/4300V/5300V<br />

Optima 4300V/5300V 1.2 mm i.d. N0771531 164<br />

Quartz Injectors<br />

Quartz Injectors are designed for organic solvents and<br />

non-HF matricies. A variety of sizes are available as an<br />

alternative to the standard injector.<br />

ICP Model Dimensions Part No. Each (€)<br />

Optima 2X00/4X00/5X00 DV 0.80 mm i.d. N0775225 134<br />

Optima 2X00/4X00/5X00 DV 1.2 mm i.d. N0775226 134<br />

Optima 2X00/4X00/5X00 DV 1.6 mm i.d. N0775223 134<br />

Optima 2X00/4X00/5X00 DV 2.0 mm i.d. N0775014 134<br />

Optima 2X00/4X00/5X00 DV 3.0 mm i.d. N0775224 134<br />

Optima 3000/3000 SCR/ 1.2 mm i.d. N0681631 159<br />

3X00 RL/Plasma 400/400 WMA<br />

Optima 3000/3000 SCR/3X00 RL 1.6 mm i.d. N0695448 166<br />

Optima 3000/3000 SCR/3X00 RL 2.0 mm i.d. N0695441 166<br />

Optima 3X00 XL/3X00 DV/ 0.8 mm i.d. N0695461 166<br />

3000 SCX/4300V/5300V<br />

Optima 3X00 XL/3X00 DV/ 1.2 mm i.d. N0695460 166<br />

3000 SCX/4300V/5300V<br />

Optima 3X00 XL/3X00 DV/ 1.6 mm i.d. N0695449 166<br />

3000 SCX/4300V/5300V<br />

Optima 3X00 XL/3X00 DV/ 2.0 mm i.d. N0695442 159<br />

3000 SCX/4300V/5300V<br />

Plasma 400/400 WMA 1.6 mm i.d. 00473292 134<br />

Sapphire Injectors<br />

Sapphire injectors are ideal for silicon applications.<br />

ICP Model Dimensions Part No. Each (€)<br />

Optima 2X00/4X00/5X00 DV 2.0 mm i.d. N0775247 1052<br />

Optima 3000/3000 SCR/3X00 RL 2.0 mm i.d. N0695495 995<br />

Optima 3X00 XL/3X00 DV/ 2.0 mm i.d. N0695494 995<br />

3000 SCX/4300V/5300V<br />

Injector Support Adapters<br />

Spray<br />

ICP Model Chamber Part No. Each (€)<br />

Optima 2X00/4X00/5X00 DV All N0770603 319<br />

Optima 3000/3000 SCR/3X00 RL Ryton Scott N0695214 126<br />

Optima 3X00 XL/3X00 DV/ Ryton Scott N0695400 242<br />

3000 SCX<br />

Optima 3X00 XL/3X00 DV/ Cyclonic N0690780 242<br />

3000 SCX<br />

Optima 4300V/5300V (bottom) Cyclonic N0771526 284<br />

Optima 4300V/5300V (top) Cyclonic N0771527 121<br />

Plasma 400/400 WMA Ryton Scott N0582248 112<br />

Injector Support Adapter O-Ring Kits<br />

ICP Model Part No. Each (€)<br />

Optima 2X00/4X00/5X00 DV N0770438 13<br />

Optima 3000/3000 SCR/3X00 RL N0690269 25<br />

Optima 3X00 XL/3X00 DV/3000 SCX/ N0690769 25<br />

4300V/5300V<br />

Plasma 400/400 WMA N0580539 59<br />

(Includes O-Rings for the Type II Demountable Torch)<br />

Injector and Adapter for<br />

Optima 3X00 XL/3X00 DV/3000 SCX<br />

A<br />

B<br />

Components Part No. Each (€)<br />

2.0 mm i.d. Alumina Injector N0695362 166<br />

Injector Support Adapter N0695400 242<br />

A<br />

B<br />

220


Sample Introduction<br />

Nebulizers<br />

CETAC Ultrasonic Nebulizer<br />

The CETAC Ultrasonic Nebulizer expands the analytical<br />

capacity of your ICP-OES instrument by increasing your<br />

sample introduction efficiency. You can typically expect<br />

an improvement of detection limits by a factor of 10.<br />

The U-5000AT + Ultrasonic Nebulizer uses mechanical forces<br />

from an oscillating transducer to break a liquid sample<br />

stream into very small droplets with a relatively uniform<br />

droplet size. Because the formation of this fine aerosol is so<br />

efficient, a desolvation system consisting of a heated tube<br />

and a condenser is placed after the nebulization chamber<br />

to remove most of the water.<br />

The U-6000AT + allows direct analysis of organic solvents by<br />

ICP-OES. When the U-6000AT + is used, the green C 2 molecular<br />

bands are eliminated. This efficient desolvation system<br />

produces a robust plasma with minimal spectral interferences.<br />

Can be used with all PerkinElmer ICP and ICP-MS instruments.<br />

Includes one Ultrasonic Nebulizer and Cooling System.<br />

U-5000AT + Ultrasonic Nebulizer System<br />

Description Part No. Each (€)<br />

115 V 50/60 Hz N8120140 13800<br />

230 V 50/60 Hz N8120141 13800<br />

U-6000AT + Ultrasonic Nebulizer System<br />

Description Part No. Each (€)<br />

115 V 50/60 Hz N0691709 26400<br />

230 V 50/60 Hz N0691710 26400<br />

Replacement Parts:<br />

Description Part No. Each (€)<br />

Drain Tubing 02506516 1<br />

Drain Pump Tubing and Connector Kit N8122150 183<br />

Argon Carrier and Sample Tubing 02506517 1<br />

Transducer Assembly N8122161 933<br />

KALREZ ® O-Ring for Spray Chamber N8122162 561<br />

Concentric Nebulizers<br />

MEINHARD Nebulizers<br />

The MEINHARD ® concentric<br />

glass nebulizer reflects exacting<br />

standards in design and<br />

manufacturing. Its advantages<br />

include simplicity of design<br />

and operation, reproducible<br />

and self-aligning aerosol, and<br />

close fabrication control. They<br />

provide excellent sensitivity and precision for aqueous<br />

solutions and samples with few dissolved solids (less than<br />

1%). MEINHARD Nebulizers are self-aspirating and must<br />

be used with solutions containing hydrofluoric acid.<br />

PerkinElmer offers three types for ICP-OES, MEINHARD A,<br />

C, and K. All require an End Cap for use with Ryton Scott<br />

Spray Chambers. See End Cap product listing below for<br />

the correct part number.<br />

MEINHARD Model Application Part No. Each (€)<br />

Type A General Purpose 00472020 587<br />

Type C High Dissolved Solids 00472022 727<br />

Type K Reduced Flow, and Organics N0681574 918<br />

End Cap for GemCone TM<br />

and Concentric Glass Nebulizers<br />

ICP Model Part No. Each (€)<br />

Optima 2X00/3X00/4X00/5X00 N0680504 261<br />

MicroMist Nebulizers<br />

The MicroMist micro-uptake glass concentric nebulizer<br />

offers high performance for limited sample volumes.<br />

MicroMists with sample uptakes 0.2 - 0.6 mL/min. are fitted<br />

with an EzyFit connector with 1.3 mm o.d. x 0.50 mm i.d. x<br />

700 mm long sample tubing. MicroMists with sample uptakes<br />

0.05 - 0.1 mL/min. are fitted with an EzyFit connector with<br />

1.3 mm o.d. x 0.25 mm i.d. x 700 mm long sample tubing.<br />

All MicroMist Nebulizers offered by PerkinElmer are supplied<br />

with the EzyLok argon connector.<br />

MicroMist Nebulizers with 0.7 L/min. Ar Flow for<br />

Optima 2X00/3X00 XL/3X00 DV/3000 SCX/4X00/5X00<br />

Uptake Rate Part No. Each (€)<br />

0.6 mL/min. N0775346 590<br />

0.2 mL/min. N0775347 677<br />

0.1 mL/min. N0775348 677<br />

0.05 mL/min. N0775349 870<br />

Sample Introduction Inductively Coupled Plasma – OES<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

221


Sample Introduction<br />

Nebulizers<br />

GemCone Nebulizer<br />

Inductively Coupled Plasma – OES Sample Introduction<br />

MicroMist Nebulizer<br />

Part No. N0775343<br />

MicroMist Nebulizers with 1 L/min. Ar Flow<br />

for Optima 3000/3000 SCR/3X00 RL<br />

Uptake Rate Part No. Each (€)<br />

0.4 mL/min. N0775341 590<br />

0.2 mL/min. N0775342 677<br />

0.1 mL/min. N0775343 677<br />

0.05 mL/min. N0775344 870<br />

PEEK Mira Mist ® Nebulizer<br />

The Mira Mist fits regular spray chambers as a direct<br />

replacement for glass concentric nebulizers. Its features<br />

include standard pressure (45 psi), low sample flow,<br />

and enhanced parallel path design. The Mira Mist can<br />

operate on 0.2 to 2.5 mL/min. and can handle high levels<br />

of particulates in the sample. Use this nebulizer for analysis<br />

of aqueous samples on the Optima 2X00/4X00/5X00.<br />

ICP Model Part No. Each (€)<br />

Optima 2X00/4X00/5X00 N0775330 1071<br />

SeaSpray Nebulizer<br />

Part No. N0775340<br />

SeaSpray Nebulizers<br />

The SeaSpray Concentric Nebulizer is ideal for samples with<br />

high dissolved solids and offers outstanding nebulization<br />

efficiency for trace level analyses. It offers freedom from<br />

clogging while nebulizing solutions to the limit of<br />

solubility of most mineral salts, and conferring significant<br />

sensitivity gains.<br />

All SeaSpray Nebulizers listed are supplied with an EZT-075<br />

EzyFit connector (sample tube 0.75 mm i.d. x 1.3 mm o.d.).<br />

All SeaSpray Nebulizers offered by PerkinElmer are<br />

supplied with the EzyLok argon connector.<br />

Ar Flow<br />

Uptake<br />

Rate ICP Model Rate Part No. Each (€)<br />

0.7 L/min. Optima 2X00/3X00 XL/ 2 mL/min. N0775345 750<br />

3X00 DV/3000 SCX/<br />

4X00/5X00<br />

1 L/min. Optima 3000/ 2 mL/min. N0775340 750<br />

3000 SCR/3X00 RL<br />

GemCone High Dissolved Solids Nebulizer<br />

GemCone Low Flow Nebulizers<br />

High Solids GemCones<br />

are for samples with high<br />

dissolved solids (up to<br />

20%). GemCone Nebulizers<br />

require an End Cap for use<br />

with Ryton Scott Spray<br />

Chambers. Please see End<br />

Cap product listing below<br />

for the correct part number.<br />

Low Flow GemCones<br />

permit lower nebulizer<br />

gas flow rates, useful for<br />

spectral lines with high<br />

excitation energies and<br />

for providing a more<br />

robust plasma. GemCone<br />

Nebulizers require an End<br />

Cap for use with Ryton<br />

Scott Spray Chambers.<br />

Please see End Cap<br />

product listing below for<br />

the correct part number.<br />

ICP Model Part No. Each (€)<br />

2X00/4X00/5X00/ N0770358 434<br />

3X00 N0690671 638<br />

GemCone Sample Capillary Adapter<br />

Plastic fitting that connects the<br />

capillary sample tube to the nebulizer.<br />

End Cap for GemCone<br />

and Concentric Glass Nebulizers<br />

Part No.<br />

Each (€)<br />

N0690670 638<br />

Part No.<br />

Each (€)<br />

N0371505 13<br />

ICP Model Part No. Each (€)<br />

Optima 2X00/3X00/4X00/5X00 N0680504 261<br />

222


Sample Introduction<br />

Nebulizers<br />

GemTip Crossflow Nebulizer<br />

GemTip TM Crossflow II Nebulizer<br />

for the Optima 2X00/4X00/5X00<br />

Part No. N0770546<br />

GemTip Crossflow II Nebulizers<br />

Excellent general purpose nebulizer for the analysis of<br />

strong mineral acids (including HF) and samples with less<br />

than 5% dissolved solids. It can routinely handle 50% (v/v)<br />

solutions of HCl, HNO 3 , H 2 SO 4 , H 3 PO 4 , 20% (v/v) HF and<br />

30% (v/v) NaOH. Up to 20% NaCl can be aspirated by the<br />

nebulizer for 1 hour without clogging. Uses chemically<br />

resistant GemTips made of sapphire and ruby in a<br />

Ryton End Cap for maximum chemical resistance.<br />

ICP Model Part No. Each (€)<br />

Optima 2X00/4X00/5X00 N0770546 593<br />

Optima 3X00 N0680503 504<br />

GemTip Crossflow II Nebulizer and End Cap Retrofit Kit<br />

This kit includes the GemTip Crossflow II Nebulizer, End Cap<br />

Assembly and the fittings required to install the nebulizer<br />

for the first time on the Plasma<br />

40/400, Plasma 1000/2000, and<br />

Optima 3X00 instruments.<br />

Part No.<br />

N0680610<br />

Each (€)<br />

599<br />

GemTip Crossflow Nebulizer II<br />

Tip Kits Part No. N0690676<br />

GemTip Crossflow<br />

Nebulizer Tip Kits<br />

Includes a clear sapphire sample<br />

tip (0.012 in. i.d.) and a red ruby<br />

argon tip (0.009 in. i.d.). The tips<br />

are constructed of PEEK with the<br />

gem inserts noted for maximum<br />

corrosion resistance. Used in all<br />

GemTip Crossflow Nebulizers.<br />

Description Part No. Each (€)<br />

GemTip Crossflow II N0690676 176<br />

GemTip Crossflow N0580624 112<br />

GemTip Crossflow O-Ring Kit<br />

GemTip Crossflow II Nebulizer<br />

for the Optima 3X00<br />

Part No. N0680503<br />

Includes two of 09902001, two of 09902033, three of<br />

09902151, one of 09921003, and 3 cm of Teflon sample tubing.<br />

Part No.<br />

Each (€)<br />

N9300067 33<br />

GemTip Crossflow II Nebulizer Replacement Parts<br />

1<br />

2<br />

3<br />

4<br />

*<br />

5<br />

6<br />

7<br />

8<br />

9<br />

10<br />

11<br />

a<br />

b<br />

12<br />

13<br />

14<br />

15<br />

16<br />

17<br />

18<br />

2<br />

Description Part No. Each (€)<br />

Screws (two) – Knurled 00473539 15<br />

Ring 00473543 28<br />

O-Ring, 18W, 1-3/8 i.d., 1-5/8 o.d. 09902033 5<br />

Fitting Reducer 1/8 TBG, 1/4 Port 09903471 12<br />

These parts are included with item 4<br />

Ferrule – TBG 1/8 Tefzel 09920515 9<br />

Nut – TBG Flanged 0.0625 PEEK 09920546 8<br />

Nut – TBG Flanged 0.125 PEEK 09920545 8<br />

Ferrule – TBG 1/16 Tefzel 09920518 9<br />

Tubing, 0.032 i.d. x 0.016 Wall, 09985708 7<br />

Teflon ® (per foot)<br />

Tubing, 0.06 i.d. x 1/8 o.d., 02506483 3<br />

Teflon (per foot )<br />

Tip Kit for Crossflow Nebulizer N0690676 176<br />

Argon and Sample tip (one each)<br />

Argon Tip (Red)<br />

Sample Tip (Clear)<br />

End Cap Crossflow Nebulizer N8122239 201<br />

O-Rings (two) 0.126 i.d., 09921045 1<br />

0.040 WD, Viton<br />

Tubing (10 feet ) – 0.023 i.d., Clear 09908265 29<br />

Nut – Hex – 0.250 TBG BRS 09903199 1<br />

Ferrule – Back 1/4 BRS 09903104 1<br />

Ferrule – Front 1/4 BRS 09903103 1<br />

Insert – Tubing 00473578 13<br />

Barbed coupler – Not Shown 09920186 4<br />

13<br />

11 b<br />

8<br />

6<br />

9<br />

14<br />

3 12<br />

1<br />

13<br />

11 a<br />

5<br />

17 16 15<br />

4<br />

7<br />

*<br />

18<br />

*<br />

*<br />

10<br />

Sample Introduction Inductively Coupled Plasma – OES<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

223


Sample Introduction<br />

Peristaltic Pump Supplies and Accessories<br />

Inductively Coupled Plasma – OES Sample Introduction<br />

Peristaltic Pump<br />

Gilson ® 4-Channel Peristaltic Pump<br />

The Gilson 4-Channel Peristaltic Pump can be used<br />

with the Optima Series of ICP spectrometers. The<br />

Pump requires, but does not include, the Gilson Pump<br />

Adapter Cable (N0690262) for computer control by the<br />

Optima 3X00. No computer control of the Pump is<br />

available for the Optima 2X00/4X00/5X00. All Optima<br />

2X00/4X00/5X00 spectrometers are Part No. Each (€)<br />

supplied with a 3-channel peristaltic<br />

pump as standard equipment.<br />

N8122126 3877<br />

Gilson Pump Adapter Cable<br />

Connects the Gilson Pump to the<br />

Optima 3X00 for computer control<br />

of the pump.<br />

On-line Internal Standard Addition Kit<br />

for the Optima Series<br />

This kit uses the third channel of the Optima pump and<br />

allows the automatic addition of an internal standard to<br />

standards, blanks, and samples.<br />

It includes peristaltic pump tubing<br />

(N0695476) and FIAS fittings.<br />

Part No.<br />

N0690673<br />

Each (€)<br />

912<br />

Peristaltic Pump Head<br />

For use with Optima 2X00/4X00/5X00.<br />

Roller Material Part No. Each (€)<br />

Plastic (Delrin) N0690284 402<br />

Stainless Steel N0690360 1046<br />

Peristaltic Pump Shelf for the Optima 3000 Family<br />

An optional shelf for the peristaltic pump that hangs from<br />

the sample shelf. Useful if extra space<br />

is required on the sample shelf.<br />

Part No. Each (€)<br />

N0690639 344<br />

Peristaltic Pump Tubing<br />

Nebulizer Capillary Tubing<br />

Part No.<br />

Each (€)<br />

N0690262 87<br />

10 ft. (3 m) length of polyethylene tubing, 0.023 in. (0.6 mm)<br />

i.d. x 0.038 in. (0.97 mm) o.d. Tubing is used between the<br />

nebulizer and the pump tubing. For use<br />

with GemTip Crossflow and GemCone<br />

High Dissolved Solids Nebulizers.<br />

Part No.<br />

09908265<br />

Each (€)<br />

29<br />

Peristaltic Pump Tubing<br />

Peristaltic pump tubing comes in a package of 12,<br />

30 cm (1 foot) lengths, unless otherwise noted.<br />

Dimensions Color Specifications Part No. Each (€)<br />

0.76 mm i.d. Black Standard PVC Peristaltic 09908587 59<br />

Pump Tubing, resistant to<br />

most mineral acids.<br />

1.14 mm i.d.* Red PVC Tubing for use with N0680375 99<br />

pump drain accessory,<br />

for 2 mL/min. flow rate.<br />

1.14 mm i.d. Red Solvent Flex Tubing, N0680376 92<br />

specially formulated PVC<br />

for use with kerosene<br />

or xylene. Not recommended<br />

for use with MIBK (methyl<br />

isobutyl ketone). For use<br />

with pump drain accessory.<br />

0.76 mm i.d. Black Solvent Flex Tubing, 00473550 59<br />

specially formulated PVC<br />

for use with kerosene<br />

or xylene. Not recommended<br />

for use with MIBK (methyl<br />

isobutyl ketone).<br />

0.76 mm i.d. Black Silicone Manifold Tubing, 00473552 88<br />

for use with organic<br />

solvents including MIBK.<br />

Not recommended for use<br />

with kerosene or xylene.<br />

1.14 mm i.d. Red Silicone Manifold Tubing, N0691595 149<br />

for use with organic<br />

solvents including MIBK.<br />

Not recommended for use<br />

with kerosene or xylene.<br />

For use with pump<br />

drain accessory.<br />

*Includes 6 in. (152 cm) PTFE Tubing (09985708) to adapt 0.045 in.<br />

(1.14 mm) i.d. tubing to the Nebulizer Capillary Tubing (09908265).<br />

PTFE Tubing<br />

1 ft (0.3 m) length of PTFE tubing, 0.79 mm o.d. x<br />

0.41 mm i.d. Used to connect capillary tubing (09908265)<br />

to GemTip Crossflow Nebulizers, and<br />

to larger i.d. Peristaltic Pump Tubing. Part No. Each (€)<br />

Teflon Tubing<br />

09985708 7<br />

1 meter length of Teflon tubing, 1 mm i.d. For delivering<br />

and pumping out the sample. Used with larger i.d. solvent<br />

flex tubing. Also used with<br />

the pumped drain assembly.<br />

Part No. Each (€)<br />

B0029792 2<br />

224


Sample Introduction<br />

Spray Chambers<br />

Cyclonic Spray Chamber<br />

The spray chamber is an integral part of the sample<br />

introduction system responsible for filtering the sample<br />

mist to permit the appropriate droplet size distribution to<br />

reach the plasma. The cyclonic spray chamber relies on<br />

momentum to efficiently and quickly remove the larger<br />

droplets from the sample mist decreasing any opportunity<br />

for occlusion or agglomeration of the smaller droplets.<br />

The result is higher efficiency, better precision, and<br />

faster washouts than other spray chamber designs.<br />

Save time and expense<br />

1. Decreased sample introduction system installation and<br />

optimization time due to the preset nature of the spray<br />

chamber/nebulizer combination.<br />

2. More samples per hour due to minimal dead volume<br />

and efficient draining.<br />

Unique design characteristics<br />

1. The nebulizer port is oversized so that sample solution<br />

cannot build up around the nebulizer as it will in other<br />

cyclonic designs. This translates to less carryover,<br />

faster washout times, and greater productivity from<br />

your Optima.<br />

2. The nebulizer port angle is tightly controlled so that the<br />

nebulizer mist impacts on the same chamber wall area<br />

in each and every spray chamber. The angle of incidence<br />

is critical in determining the efficiency of large<br />

droplet removal.<br />

3. A trace metal free plastic nebulizer adapter is employed<br />

to fix the depth of nebulizer insertion at the optimal<br />

position. Because of this, there is no need for an operator<br />

to move the nebulizer in and out of the port in an effort<br />

to locate the “sweet spot”.<br />

4. Each spray chamber incorporates a precisely machined<br />

ridge along the inside top of the spray chamber. Both the<br />

angle and depth of the ridge are critical to performance.<br />

The result is efficient draining of sample waste and the<br />

elimination of large droplets being swept into the plasma.<br />

This eliminates the periodic “spiking” that adversely<br />

affects precision and fosters faster washout times.<br />

Cyclonic Spray Chambers<br />

Standard and O-Ring Free Glass Cyclonic Spray Chambers<br />

can be used with either GemCone or Concentric Glass<br />

Nebulizers. HF Resistant Cyclonic Spray Chambers should<br />

be used with GemCone, SeaSpray, or MicroMist nebulizers.<br />

ICP Model Type Part No. Each (€)<br />

Optima 2X00/4X00/5X00 Standard N0776052 791<br />

Optima 2X00/4X00/5X00 O-Ring Free N0775351 584<br />

Optima 2X00/4X00/5X00 HF Resistant N0775357 1704<br />

Optima 3X00 DV/XL/3000 SCX Standard N8122188 606<br />

Optima 3X00 DV/XL/3000 SCX O-Ring Free N0775350 584<br />

Cyclonic Spray Chamber, Standard<br />

Part No. N0776052<br />

Baffled Cyclonic Spray Chambers<br />

The Baffled Cyclonic Spray Chamber features a central<br />

transfer tube which acts as a secondary particle separator,<br />

helping to separate larger aerosol particles from the sample.<br />

This reduces solvent load in the plasma without<br />

compromising detection limits.<br />

The internal baffle design has two important characteristics:<br />

1. The distance between the bottom of the baffle and the<br />

chamber wall is carefully controlled so that droplets<br />

cannot form on the bottom of the baffle. The advantage<br />

is smooth draining and improved precision.<br />

2. The baffle is cut at a sharp angle so that a large<br />

cross-section of the spray chamber is sampled as<br />

opposed to a straight cut which would have a very<br />

small sampling cross-section. The advantage is more<br />

representative sampling and reduced matrix effects.<br />

ICP Model Type Part No. Each (€)<br />

Optima 2X00/4X00/5X00 DV Standard N0776053 956<br />

Optima 2X00/4X00/5X00 DV O-Ring Free N0775352 704<br />

Optima 2X00/4X00/5X00 DV O-Ring Free N0775355 704<br />

for Organics<br />

(4 mm baffle)<br />

Optima 4300V/5300V Standard N0771501 800<br />

Optima 4300V/5300V O-Ring Free N0775356 704<br />

Optima 4300V/5300V HF Resistant N0771550 2071<br />

Baffled Cyclonic Spray Chamber,<br />

Standard Part No. N0776053<br />

Cyclonic Spray Chamber, O-Ring<br />

Free Part No. N0775351<br />

Baffled Cyclonic Spray Chamber,<br />

O-Ring Free Part No. N0775352<br />

Sample Introduction Inductively Coupled Plasma – OES<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

225


Sample Introduction<br />

Spray Chambers<br />

Inductively Coupled Plasma – OES Sample Introduction<br />

Ryton Scott Spray Chamber and Replacement Parts<br />

Ryton Scott Spray Chambers<br />

The Ryton Scott Spray Chamber is made from corrosionresistant<br />

Ryton, which is inert to most mineral acids including<br />

HF, Aqua Regia, and all organic solvents normally used in ICP<br />

analyses. The Scott-type design minimizes pulsations from<br />

the peristaltic pump. The Type II, two-piece design ensures<br />

leak-free performance. The removable inner tube allows the<br />

chamber to be easily disassembled for cleaning.<br />

ICP Model Part No. Each (€)<br />

Optima 2X00/4X00/5X00 N0770357 112<br />

Optima 3000/3000 SCR/3X00 RL N0690640 191<br />

Optima 3X00 DV/XL/3000 SCX N0690720 191<br />

Plasma 400 (Complete) N0580542 338<br />

Plasma 400 (Inner Tube) N0582259 198<br />

Plasma 400 (Outer Chamber) N0582258 60<br />

Ryton Scott External Spray Chamber Kit<br />

Ryton Scott External Spray Chamber Kit Replacement Parts for the Optima 3X00<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

9<br />

10<br />

11<br />

12<br />

13<br />

14<br />

15<br />

16<br />

17<br />

18<br />

19<br />

20<br />

21<br />

1<br />

2<br />

4<br />

External Spray Chamber Kit for the Optima 3X00 series.<br />

Includes External Ryton Scott Type II Spray Chamber, 1.2 mm<br />

Quartz Injector, and appropriate<br />

mounting hardware. For use with<br />

high-volatility samples.<br />

Part No.<br />

N0690289<br />

Each (€)<br />

638<br />

Components Part No. Each (€)<br />

Polypropylene Male Compression Fitting 1/8 NPT, 1/4 in. Tubing 09903999 5<br />

Brass Male Compression Fitting, 1/8 NPT, 1/4 in. Tubing 09903428 6<br />

Aluminum Tubing Insert, 1/8 in. i.d. 1/4 in. o.d. 09903094 1<br />

Quartz Injector, 1.2 mm i.d. N0695460 166<br />

Torch Adapter (for External Spray Chamber Kit)* N0695426 159<br />

Silicone Tubing, 1/4 in. i.d., 1 m piece* B0018283 11<br />

TFE Teflon Tubing, 1/4 in., 1 m piece 02508059 13<br />

External Chamber Bracket N0695433 74<br />

Spray Chamber Adapter (for External Spray Chamber)* N0695368 214<br />

Nebulizer Argon Tube Assembly N0690677 29<br />

Silicone O-Ring (red) 0.364 in. i.d., 0.070 in. width* 09902247 2<br />

Viton O-Ring (for use with Silicone applications) 0.364 in. i.d., 0.070 in. width* 09902015 6<br />

Tygon ® Tube (F4040A), Translucent Yellow, 3/8 in. i.d., cut to 3/4 in.* 02506532 3<br />

Drain Adapter* N0695414 46<br />

Barbed Elbow Fitting, Kynar, 10-32 UNF Male, 3/32 in.* 09920262 3<br />

Solvent Flex Tubing, Yellow PVC, 0.060 in. i.d.* 09985729 2<br />

Barbed Coupler Fitting, Kynar, 3/32 in. Tubing to 3/32 in. Tubing 09920186 4<br />

Spray Chamber (inner) to be Assembled with Item 19* N0582258 60<br />

Spray Chamber (outer)* N0695222 225<br />

Machine Screw, 4-40 x 5/16 in. long, Binding Head SS<br />

Component Clip, 1.375 in. i.d. (to hold External Spray Chamber) 09986072 50<br />

*Can also be used as replacement parts for the Single-Slot Demountable Torch Assembly<br />

with External Spray Chamber (N0770608), for the Optima 2X00/4X00/5X00.<br />

3<br />

5<br />

6 7 10 8<br />

14<br />

15<br />

13<br />

16<br />

17<br />

18 / 19<br />

20<br />

9<br />

11<br />

12<br />

21<br />

226


Sample Introduction<br />

Torches and Torch Accessories<br />

Torches<br />

Torch Modules and Assemblies<br />

Demountable Quartz Torch<br />

for Optima 2X00/4X00/5X00 DV,<br />

Single-Slot Part No. N0770338<br />

Demountable<br />

Quartz Torches<br />

Demountable design using<br />

one-piece quartz tubing for<br />

plasma and auxiliary gas<br />

flow. Available in a wide<br />

range of styles from 0-3 Slots,<br />

depending on your instrument<br />

and application needs. Torches<br />

without slots are recommended<br />

for organic solvents. 1-Slot<br />

torches are the standard torch<br />

for aqueous solutions. 3-Slot<br />

torches are typically used for<br />

organics analysis.<br />

ICP Model # of Slots Part No. Each (€)<br />

Optima 2X00/4X00/5X00 DV 0 N0770343 306<br />

Optima 2X00/4X00/5X00 DV 0 (short ver.) N0770344 306<br />

Optima 2X00/4X00/5X00 DV 1 N0770338 306<br />

Optima 3X00 DV 2 N0691662 427<br />

Optima 3000 SCX/3X00 XL 0 N0695379 427<br />

Optima 3000/3000 SCR/3X00 RL 1 N0690568 427<br />

Optima 3000/3000 SCR/3X00 RL 3 N0681690 599<br />

and Plasma 400 Wear Metals<br />

Analyzer (for Organics)<br />

Optima 4300V/5300V 3 N0771500 427<br />

Plasma 400* 3 N0580528 453<br />

*Not to be used with the Plasma 400 Wear Metals Analyzer.<br />

Torch Bonnets<br />

Torch Bonnets<br />

The torch bonnet is used as a spacer between<br />

the Torch and RF Load Coil.<br />

ICP Model Part No. Each (€)<br />

Optima 2X00/4X00/5X00 N0775289 98<br />

Optima 3000/3000 SCR/3X00 RL N0695295 102<br />

(for instruments manufactured BEFORE 9/21/94)<br />

Optima 3000/3000 SCR/3X00 RL N0695456 236<br />

(for instruments manufactured AFTER 9/21/94)<br />

Optima 3X00 XL/3X00 DV N0691664 134<br />

Quick-Change Torch Module in Quick-Change<br />

Torch Module Support Stand<br />

Quick-Change Torch Module with Cyclonic Spray<br />

Chamber and Concentric Nebulizer<br />

Complete Torch and Sample<br />

Introduction Module including<br />

complete Single-Slot Demountable<br />

Torch, Mounting Block, 2 mm<br />

Alumina Injector, Cyclonic Spray<br />

Chamber, and MEINHARD Type C<br />

Concentric Nebulizer.<br />

ICP Model Part No. Each (€)<br />

Optima 2X00/4X00/5X00 N0770607 4005<br />

Quick-Change Torch Module with Ryton Scott<br />

Spray Chamber and GemTip Crossflow Nebulizer<br />

Complete Torch and Sample<br />

Introduction Module including<br />

Demountable Single-Slot Torch,<br />

Mounting Block, 2 mm Alumina<br />

Injector, Ryton Scott Spray Chamber,<br />

and GemTip Crossflow II Nebulizer.<br />

Useful when a separate sample<br />

introduction is required for<br />

running different sample types.<br />

For Optima 2X00/4X00/5X00<br />

Part No. N0770606<br />

ICP Model Part No. Each (€)<br />

Optima 2X00/4X00/5X00 DV N0770606 3469<br />

Optima 3000/3000 SCR/3X00 RL N0690610 2678<br />

Optima 3X00 DV N0690812 3214<br />

Optima 3X00 XL/3000 SCX N0690712 3214<br />

Quick-Change Torch Module Support Stand<br />

A free-standing support stand to hold your spare Quick-<br />

Change Torch Module or as a means of conveniently holding<br />

your module when working inside the sample compartment.<br />

ICP Model Part No. Each (€)<br />

Optima 2X00/4X00/5X00 DV N0770609 128<br />

Optima 3X00 N0690636 204<br />

Mounting Block for Quick Change Torch Modules<br />

Mounting block only. Does not include torch, injector, spray<br />

chamber, or nebulizer. For Optima 2X00/4X00/5X00.<br />

Part No.<br />

Each (€)<br />

N0770600 2270<br />

Sample Introduction Inductively Coupled Plasma – OES<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

227


Inductively Coupled Plasma – OES Sample Introduction<br />

Sample Introduction<br />

Torches and Torch Accessories<br />

Quick-Change Torch Module for Dry Aerosols<br />

A Quick-Change Torch Module designed for the introduction<br />

of dry sample aerosols, such as ultrasonic nebulization, laser<br />

sampling, spark ablation, and electrothermal vaporization.<br />

For use with the Optima 3000, 3000 SCR, and 3X00 RL.<br />

Includes Single-Slot Demountable Torch, 2 mm Alumina<br />

Injector, Dry Aerosol Injector Support<br />

Adapter, Mounting Block, Gas Lines, Part No. Each (€)<br />

and Fittings.<br />

N0690638 1990<br />

Dry Aerosol Block and Injector Assembly<br />

Allows the standard Quick-Change Torch Module to be used<br />

as a dry aerosol system. For use with the Optima 3000, 3000<br />

SCR, and 3X00 RL. Includes Dry Aerosol<br />

Injector Support Adapter, Mounting<br />

Block, and Fittings.<br />

Part No.<br />

N0690637<br />

Each (€)<br />

414<br />

Dry Aerosol Adapter for Ultrasonic Nebulization<br />

Adapter to connect 1/4 in. tubing to Injector Support Adapter<br />

(N0695400 or N0770603). For use with ultrasonic nebulization<br />

with the Optima 2X00 DV, 3X00 XL, 3X00 DV, 3000 SCX,<br />

4X00 DV, and 5X00 DV.<br />

Part No. Each (€)<br />

Quick-Change Torch Module<br />

for HF-Resistant Analysis<br />

Complete Torch and Sample Introduction Assembly for the<br />

Optima 4300V and 5300V, including the 3-Slot Demountable<br />

Quartz Torch, Mounting Block, 2 mm Alumina Injector,<br />

HF Resistant Cyclonic Spray Chamber, and GemCone<br />

High Dissolved Solids Nebulizer.<br />

Part No. Each (€)<br />

Quick-Change Torch Module for Used Oil Analysis<br />

Complete Torch and Sample Introduction Assembly<br />

for the Optima 4300V and 5300V, including the 3-Slot<br />

Demountable Quartz Torch, Mounting Block, 1.2 mm<br />

Alumina Injector, Baffled Cyclonic<br />

Spray Chamber, and GemCone<br />

Low-Flow Nebulizer.<br />

Part No.<br />

N0770910<br />

Each (€)<br />

2100<br />

Single-Slot Demountable Torch Assembly<br />

with External Spray Chamber<br />

N0690770 145<br />

N0770911 3799<br />

Complete Torch and External Spray Chamber Assembly<br />

for the Optima 2X00/4X00/5X00, including Single-Slot<br />

Demountable Torch, 2 mm Quartz Injector, 1.6 mm Quartz<br />

Injector, External Ryton ® Scott Type II Spray Chamber,<br />

O-Rings, and appropriate mounting<br />

hardware. For use with<br />

high-volatility samples.<br />

Part No.<br />

N0770608<br />

Each (€)<br />

1943<br />

Demountable Type II Torch Assembly<br />

with Ryton ® Type II Spray Chamber<br />

Complete Torch and Spray Chamber Assembly for the Plasma<br />

400, including Type II Demountable Torch, Mounting Block,<br />

2 mm Alumina Injector, Ryton Type II<br />

Spray Chamber, O-Ring Kit, and<br />

appropriate mounting hardware.<br />

Part No.<br />

N0680241<br />

Each (€)<br />

1250<br />

Torch Replacement Parts<br />

Torch O-Rings<br />

ICP Model Location Dimensions Part No. Each (€)<br />

Optima 2X00/3X00/ Torch 0.612 i.d., 09902155 3<br />

4X00/5X00 DV Base Mount 0.103 w.d.<br />

Optima 3X00 XL/ 0.239 i.d., 09902006 2<br />

3X00 DV/3000 SCX<br />

0.070 w.d.<br />

Optima 3X00 XL/ 0.364 i.d., 09902015 6<br />

3X00 DV/3000 SCX<br />

0.070 w.d.<br />

Optima 3X00 XL/ 8.74 i.d., 09921028 1<br />

3X00 DV/3000 SCX<br />

1.78 w.d.<br />

Optima 3X00 XL/ Torch 0.239 i.d., 09902207 4<br />

3X00 DV/3000 SCX/ Adapter - 0.070 w.d.<br />

4300V/5300V Inside<br />

Optima 3X00 XL/ Torch 0.301 i.d., 09902247 2<br />

3X00 DV/3000 SCX/ Adapter - 0.070 w.d.<br />

4300V/5300V Outside<br />

Optima 4300V/5300V Ball Joint 0.301 i.d., 09926070 1<br />

0.070 w.d.<br />

Plasma 400 09902152 2<br />

Plasma 400 09902225 1<br />

Torch O-Ring Kits<br />

Kits contain a selection of O-Rings for ICP Demountable<br />

Torches. Replacement of the torch O-Rings is normally<br />

recommended when replacing a quartz torch.<br />

ICP Model Part No. Each (€)<br />

Optima 2X00/4X00/5X00 N0770437 27<br />

Optima 3000/3000 SCR/3X00 RL N0690269 25<br />

Optima 3X00 XL/3X00 DV/3000 SCX N0690769 25<br />

Plasma 400/400 WMA N0580539 59<br />

(includes O-Rings for the Injector Support Adapter)<br />

Plasma Gas/Ignitor Cable “T” Connection<br />

for Optima 3000/3000 XL<br />

Quartz Torch Copper Ignitor Tape<br />

Used for all torches with the<br />

Optima 2X00/4X00/5X00.<br />

Sheet with 48 squares.<br />

Part No.<br />

Part No.<br />

Each (€)<br />

N0690607 62<br />

Each (€)<br />

N0775297 13<br />

228


Sample Introduction<br />

Torches and Torch Accessories<br />

Torch Replacement Parts<br />

Quick-Change Torch Module Replacement Parts<br />

for Optima 3000, 3X00 RL, and 3X00 SCR<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

9<br />

10<br />

11<br />

12<br />

13<br />

14<br />

15<br />

16<br />

17<br />

18<br />

19<br />

20<br />

21<br />

22<br />

23<br />

24<br />

25<br />

26<br />

27<br />

28<br />

Components Part No. Each (€)<br />

Thumbscrew #10 N0580534 8<br />

GemTip TM Crossflow II Nebulizer and N0680503 504<br />

End Cap Assembly<br />

Alumina Injector, 2.0 mm i.d. N0582184 159<br />

Ryton Scott Spray Chamber – N0582258 60<br />

Inner Tube (combine with item 12)<br />

Quartz Torch Demountable, Single Slot N0690568 427<br />

Assembly – Adjustable Mount N0690593 1160<br />

Cable Assembly – RF Ignitor N0690607 62<br />

Fitting – N0695214 126<br />

Couple Injector to Spray Chamber<br />

Support – Torch N0695220 268<br />

Ryton Scott Spray Chamber – N0695222 225<br />

Outer Tube (combine with item 4)<br />

Pointer – Adjustable Mount N0695225 22<br />

Clamp Plate N0695238 73<br />

Screw, Knurled N0581558 51<br />

Clamp Bracket N0581793 24<br />

O-Ring 00473194 4<br />

Clear Tygon Tubing (per foot) 02506516 1<br />

O-Ring 09902207 4<br />

O-Ring 09902155 3<br />

O-Ring 09902247 2<br />

Insert 09903094 1<br />

O-Ring 09902015 6<br />

Screw – BDHM 6-32 x 1/4 in.<br />

Polyethylene Tube (per foot) 02506517 1<br />

Connector 1/8 NPT to 1/4 TBG<br />

Insert 1/4 in. o.d. 3/16 in. i.d. 09920118 7<br />

Marker – Plasma 09940438 28<br />

Marker – Aux<br />

Barb Fitting Male – 10-32 NPT 1/8 TBG 09920034 2<br />

Demountable Torch Replacement Parts<br />

for Optima 3X00<br />

A<br />

B<br />

C1<br />

C2<br />

1<br />

2<br />

3<br />

Components Part No. Each (€)<br />

Alumina Injector, 2.0 mm i.d.:<br />

Optima 3000/3000 SCR/3X00 RL N0582184 159<br />

Optima 3000 DV/3000 SCX/3X00 XL N0695362 166<br />

Demountable Quartz Torch:<br />

Single Slot for Optima 3000/ N0690568 427<br />

3000 SCR/3X00 RL<br />

No Slot Torch N0695379 427<br />

for Optima 3X00 SCX/3X00 XL<br />

2-Slot Torch for Optima 3X00 DV N0691662 427<br />

Injector Support Adapter:<br />

Optima 3000/3000 SCR/3X00 RL N0695214 126<br />

with Ryton ® Scott Spray Chambers<br />

Optima 3000 SCX/3X00 DV/3X00 XL N0695400 242<br />

with Ryton Scott Spray Chambers<br />

Optima 3000 SCX/3X00 DV/3X00 XL N0690780 242<br />

with Cyclonic Spray Chambers<br />

O-Ring 09902155 3<br />

O-Ring 09902247 2<br />

O-Ring 09902006 2<br />

See page 220 for our full selection of Alumina, Quartz, and Saphire Injectors.<br />

5<br />

18<br />

12<br />

1<br />

9<br />

11 / 22<br />

10<br />

4<br />

C2<br />

7<br />

B<br />

1<br />

A<br />

2<br />

15<br />

23 / 25 / 27<br />

6<br />

20 / 24 / 28<br />

16 / 26<br />

3<br />

17<br />

2<br />

19<br />

8<br />

14<br />

21<br />

13<br />

3<br />

C1<br />

2<br />

Sample Introduction Inductively Coupled Plasma – OES<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

229


Sample Introduction<br />

Torches and Torch Accessories<br />

Torch Replacement Parts<br />

Quick-Change Torch Module Replacement Parts<br />

for Optima 3X00 DV, 3X00 SCX, 3X00 XL<br />

Components Part No. Each (€)<br />

Inductively Coupled Plasma – OES Sample Introduction<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

9<br />

10<br />

11<br />

12<br />

13<br />

14<br />

15<br />

16<br />

17<br />

18<br />

19<br />

20<br />

21<br />

22<br />

23<br />

24<br />

25<br />

26<br />

27<br />

28<br />

29<br />

30<br />

31<br />

Alumina Injector, 2.0 mm i.d. N0695362 166<br />

Block – Axial – Dove Tail N0695367 164<br />

Fitting – Axial N0695400 242<br />

Cable Assembly – RF Generator Ignitor N0690607 62<br />

Tygon Tubing (per foot) 02506516 1<br />

Polyethylene Tubing (per foot) 02506517 1<br />

O-Ring 00473194 4<br />

Cap – Screw 10-32, 0.625 Long, SS<br />

Barb Fitting Male – 09920034 2<br />

10-32 NPT 1/8 TBG<br />

O-Ring 09902207 4<br />

O-Ring 09902155 3<br />

O-Ring 09902247 2<br />

Tubing Insert, 0.125 i.d. 09903094 1<br />

Knob – Thumbscrew SCR 10 09908522 2<br />

6-32 x 3/8 SOC Cap Screw<br />

8-32 x 3/8 SOC Cap Screw<br />

SOC Cap 10-32 x 1/2 SS<br />

Washer, Flat #8<br />

Lock Washer, #8<br />

Quick Connect Stem 1/8 Tubing, Barb 09920021 57<br />

Clamp Hose – 1/4 in. Bypass 09903021 1<br />

Insert – Tube 1/4 o.d. x 3/16 i.d. 09920118 7<br />

O-Ring 09921028 1<br />

Knob – Thumbscrew 09923012 2<br />

Wire Marker Strip 09940438 28<br />

Bev-A-Line Tubing, 09985727 2<br />

0.125 i.d., Clear (per foot)<br />

Wire Marker – AUX<br />

Tubing Silicone (per foot) 09985514 3<br />

Axial Drain Fitting 09920528 3<br />

PVC Tubing, 1.5 mm i.d. 09985729 2<br />

Clamp Plate N0695381 51<br />

15 / 24 3 10 1<br />

23 12<br />

29<br />

30<br />

8<br />

16 / 18 / 19<br />

2 31 14 / 17<br />

11<br />

28<br />

15<br />

9<br />

“Plasma”<br />

4<br />

7 5 / 13 / 25<br />

26<br />

“Neb”<br />

“Aux”<br />

20 21 28 6 / 22 / 27<br />

230


Standards<br />

PerkinElmer Pure Standards for ICP-OES<br />

Depend on Genuine<br />

PerkinElmer Pure Standards<br />

Whatever Your Application,<br />

You Can Count on PerkinElmer<br />

Pure Standards to Yield Reliable,<br />

Accurate Results<br />

PerkinElmer offers a wide selection of standards for ICP-OES.<br />

Each solution is supplied with a comprehensive Certificate<br />

of Analysis that documents the quality. To ensure that your<br />

measurements are accurate, you can rely on our certificates<br />

to provide complete information.<br />

PerkinElmer Pure Atomic Spectroscopy Standards are manufactured<br />

for PerkinElmer to the highest quality standards.<br />

Quality<br />

PerkinElmer Pure standards are prepared<br />

gravimetrically from high-purity metals<br />

and salts, using high-purity reagents.<br />

■ ASTM Type I, filtered water minimizes cations,<br />

anions, and colloids; resistivity is maintained in<br />

the 18-megohm range.<br />

■ Acids used are the highest purity.<br />

■ Semi-micro analytical balances and Class A volumetric<br />

glassware are used, and the bottles are subjected to a<br />

stringent leaching/cleaning process.<br />

■ Following preparation, standards are analyzed<br />

for the major element as well as trace impurities.<br />

The results of the analysis are provided on the<br />

Certificate of Analysis.<br />

Reliability<br />

Multi-element standards are measured<br />

by three methods:<br />

1. Complete analysis (wet and ICP)<br />

of the starting materials<br />

2. Wet and ICP analysis of the<br />

individual prepared standards<br />

3. ICP-MS check of the final multi-element standard<br />

The results of these three analyses are<br />

reported on the Certificate of Analysis.<br />

NIST or NBS SRMs used for the ICP<br />

check are also reported on the<br />

Certificate of Analysis.<br />

Safety<br />

We ship standards to comply with both<br />

DOT and IATA regulations to ensure<br />

their safe delivery to you.<br />

Features<br />

■ ISO 9001 accredited by Underwriters Laboratories<br />

including comprehensive continuous improvement,<br />

product recall, corrective action request, and other<br />

quality maintenance and improvement programs<br />

■ Accreditation by NVLAP/NIST as an EPA performance<br />

testing provider<br />

■ Product labeling meets OSHA and California<br />

labeling standards<br />

■ Bottles are low-density polyethylene from industry<br />

standard Nalge Corporation and are pre-leached and<br />

pre-treated for increased product stability and purity<br />

■ High-purity acids and ASTM Type I water used in<br />

all manufacturing, as reported on the Certificate<br />

of Analysis<br />

■ Traceability directly to NIST standard reference<br />

materials, not independent sources or secondary<br />

NIST SRMs and reported on the Certificate<br />

of Analysis<br />

■ Wet assays on all multi-element products via<br />

standard, accepted wet methods and traceable<br />

directly to NIST SRM to +/-0.5% of true value<br />

and reported on the Certificate of Analysis<br />

■ All solutions tested and confirmed for the absence<br />

of interfering anions, e.g. chloride, bromide, etc.<br />

■ Twelve months guaranteed stability +/-0.5% for<br />

all major analytes for all products<br />

www.perkinelmer.com/<strong>supplies</strong> 231


Standards<br />

PerkinElmer Pure Standards for ICP-OES<br />

Inductively Coupled Plasma – OES Standards<br />

Alternate Trace Metal Drinking Water<br />

and Wastewater Pollution Standards<br />

Alternate Metals I<br />

Matrix/Vol. Concentration of Element Part No. Each (€)<br />

2% HNO 3 /100 mL 20 μg/mL Aluminum N9300214 190<br />

5 μg/mL Antimony<br />

5 μg/mL Beryllium<br />

10 μg/mL Cobalt<br />

10 μg/mL Copper<br />

20 μg/mL Iron<br />

10 μg/mL Manganese<br />

10 μg/mL Nickel<br />

5 μg/mL Thallium<br />

20 μg/mL Vanadium<br />

10 μg/mL Zinc<br />

Alternate Metals II<br />

Matrix/Vol. Concentration of Element Part No. Each (€)<br />

2% HNO 3 /100 mL 500 μg/mL Calcium N9300215 114<br />

100 μg/mL Magnesium<br />

100 μg/mL Potassium<br />

500 μg/mL Sodium<br />

Contract Required Detection<br />

Limits (CRDL) Standard<br />

Used to verify the Contract Required Detection Limits (CRDL)<br />

for ICP and HGA ® elements<br />

Contains all the required elements on the TAL at the correct<br />

concentration ratios<br />

Dilute by a factor of 1,000 prior to use to meet the “two times<br />

CRDL” requirement for ICP analysis and by a factor of 2,000<br />

to meet the “one times CRDL” requirement for HGA analysis<br />

Use at the start and end of each sample analysis or at least<br />

twice in an eight-hour shift for ICP, and at the start of your<br />

sample analysis run for HGA<br />

CRDL Standard<br />

Matrix/Vol. Concentration of Element Part No. Each (€)<br />

5% HNO 3 /100 mL 120 μg/mL Antimony N9300225 228<br />

20 μg/mL Arsenic<br />

10 μg/mL Beryllium<br />

10 μg/mL Cadmium<br />

20 μg/mL Chromium<br />

100 μg/mL Cobalt<br />

50 μg/mL Copper<br />

6 μg/mL Lead<br />

30 μg/mL Manganese<br />

80 μg/mL Nickel<br />

10 μg/mL Selenium<br />

20 μg/mL Silver<br />

20 μg/mL Thallium<br />

100 μg/mL Vanadium<br />

40 μg/mL Zinc<br />

Drinking Water Pollutant Standards<br />

Recommended for use in procedures for compliance<br />

monitoring of drinking water<br />

Recommended for the analysis of ground and surface<br />

water where determination at the drinking water<br />

contaminant levels is required<br />

Supplied in two bottles. Mercury (100 mL at 10 μg/mL)<br />

is included, but shipped in a separate bottle<br />

For use with U.S. EPA SW-846, method 1310 and U.S. National Primary<br />

Drinking Water Regulations 40 CFR Part 141. Secondary metals from<br />

U.S. EPA Appendix to 200.7 used in the analysis of drinking water by ICP.<br />

Primary Drinking Water Metals<br />

Matrix/Vol. Concentration of Element Part No. Each (€)<br />

2% HNO 3 /100 mL 10 μg/mL Arsenic N9300216 152<br />

100 μg/mL Barium<br />

5 μg/mL Cadmium<br />

10 μg/mL Chromium<br />

10 μg/mL Lead<br />

5 μg/mL Selenium<br />

10 μg/mL Silver<br />

10 μg/mL Mercury<br />

Secondary Drinking Water Metals<br />

Matrix/Vol. Concentration of Element Part No. Each (€)<br />

2% HNO 3 /100 mL 100 μg/mL Copper N9300217 114<br />

30 μg/mL Iron<br />

5 μg/mL Manganese<br />

500 μg/mL Zinc<br />

232


Standards<br />

PerkinElmer Pure Standards for ICP-OES<br />

Groundwater and Wastewater<br />

Pollution Control Check Standards<br />

Use as a daily control standard<br />

Check the accuracy and precision of your analysis<br />

Refer to U.S. EPA methods manual 600/4-79-020, “Methods for Chemical<br />

Analysis of Water and Wastes”: Trace metals I, II, and III methods.<br />

Trace Metals I<br />

Matrix/Vol. Concentration of Element Part No. Each (€)<br />

5% HNO 3 /100 mL 500 μg/mL Aluminum N9300211 228<br />

100 μg/mL Arsenic<br />

100 μg/mL Beryllium<br />

25 μg/mL Cadmium<br />

100 μg/mL Chromium<br />

100 μg/mL Cobalt<br />

100 μg/mL Copper<br />

100 μg/mL Iron<br />

100 μg/mL Lead<br />

100 μg/mL Manganese<br />

5 μg/mL Mercury<br />

100 μg/mL Nickel<br />

25 μg/mL Selenium<br />

250 μg/mL Vanadium<br />

100 μg/mL Zinc<br />

Trace Metals II<br />

Matrix/Vol. Concentration of Element Part No. Each (€)<br />

2% HNO 3 /100 mL 20 μg/mL Antimony N9300212 88<br />

10 μg/mL Silver<br />

20 μg/mL Thallium<br />

Trace Metals III<br />

Matrix/Vol. Concentration of Element Part No. Each (€)<br />

2% HNO 3 /100 mL 500 μg/mL Barium N9300213 152<br />

500 μg/mL Calcium<br />

100 μg/mL Magnesium<br />

500 μg/mL Molybdenum<br />

100 μg/mL Potassium<br />

500 μg/mL Sodium<br />

Instrument Calibration Standards<br />

Please see page 66 for our full selection of Instrument Calibration Standards<br />

for Contract Laboratory Program (CLP) analysis.<br />

Low UV Standard<br />

Matrix/Vol. Concentration of Element Part No. Each (€)<br />

2% HNO 3 /250 mL 10 μg/mL Aluminum N0691580 126<br />

10 μg/mL Phosphorus<br />

10 μg/mL Sulfur<br />

Calcium Stray Light Standard<br />

Matrix/Vol. Concentration of Element Part No. Each (€)<br />

H 2 O /100 mL 10,000 μg/mL Calcium N0691581 88<br />

Interference Check Standards<br />

Used to verify interelement and background correction<br />

factors required at the beginning and the end of each<br />

analysis run or at least twice in an eight-hour shift.<br />

Interference checks require two solutions: the interferents<br />

alone, and the combination of interferents and analytes.<br />

Interferents A Solution<br />

To prepare the solution of interferents alone, dilute<br />

N9300226 by a factor of 10. To prepare the solution of<br />

interferents and analytes, dilute 10 mL of interferents<br />

solution (N9300226) and 1 mL of analytes solution<br />

(N9300227) to 100 mL with 5% high-purity HNO 3 .<br />

Matrix/Vol. Concentration of Element Part No. Each (€)<br />

5% HNO 3 /500 mL 5,000 μg/mL Aluminum N9300226 356<br />

5,000 μg/mL Calcium<br />

2,000 μg/mL Iron<br />

5,000 μg/mL Magnesium<br />

Analytes B Solution<br />

Matrix/Vol. Concentration of Element Part No. Each (€)<br />

5% HNO 3 /100 mL 60 μg/mL Antimony N9300227 190<br />

10 μg/mL Arsenic<br />

50 μg/mL Barium<br />

50 μg/mL Beryllium<br />

100 μg/mL Cadmium<br />

50 μg/mL Chromium<br />

50 μg/mL Cobalt<br />

50 μg/mL Copper<br />

5 μg/mL Lead<br />

50 μg/mL Manganese<br />

100 μg/mL Nickel<br />

5 μg/mL Selenium<br />

20 μg/mL Silver<br />

10 μg/mL Thallium<br />

50 μg/mL Vanadium<br />

100 μg/mL Zinc<br />

Alternate Interferents A Solution<br />

Besides the four interferents in N9300226, six more elements<br />

that can interfere with the determination of the elements on<br />

the TAL are listed in EPA SOW.3/90 and ILM04.0. Alternate<br />

Interferents A solution contains these elements. Together<br />

these solutions enable you to check and correct for all the<br />

interferences listed in SOW.3/90.<br />

Two solutions are required. To prepare the interferents<br />

solution, combine 10 mL of N9300226 with 10 mL of<br />

N9300228 and dilute to 100 mL with 5% high-purity HNO 3 .<br />

To prepare the solution of interferents and analytes,<br />

combine 10 mL of N9300226 with 10 mL of N9300228,<br />

1 mL of N9300227 and 1 mL of N9300229 and dilute to<br />

100 mL with 5% high-purity HNO 3 .<br />

Matrix/Vol. Concentration of Element Part No. Each (€)<br />

5% HNO 3 /500 mL 1,000 μg/mL Chromium N9300228 292<br />

1,000 μg/mL Copper<br />

1,000 μg/mL Manganese<br />

1,000 μg/mL Nickel<br />

1,000 μg/mL Thallium<br />

1,000 μg/mL Vanadium<br />

Standards Inductively Coupled Plasma – OES<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

233


Standards<br />

PerkinElmer Pure Standards for ICP-OES<br />

Inductively Coupled Plasma – OES Standards<br />

Alternate Analytes B Solution<br />

Matrix/Vol. Concentration of Element Part No. Each (€)<br />

5% HNO 3 /100 mL 100 μg/mL Aluminum N9300229 228<br />

100 μg/mL Arsenic<br />

100 μg/mL Boron<br />

10 μg/mL Calcium<br />

10 μg/mL Iron<br />

10 μg/mL Magnesium<br />

100 μg/mL Molybdenum<br />

100 μg/mL Sodium<br />

100 μg/mL Antimony<br />

100 μg/mL Selenium<br />

10 μg/mL Silicon<br />

100 μg/mL Thallium<br />

Interference Check Standard, 18<br />

Use to set or confirm that the correct background correction<br />

intervals have been set. For use in U.S. EPA SW-846,<br />

method 6010 section 5.7 and method 200.7 section 7.6.2.<br />

Matrix/Vol. Concentration of Element Part No. Each (€)<br />

5% HNO 3 /100 mL 1,000 μg/mL Arsenic N9300205 381<br />

300 μg/mL Barium<br />

100 μg/mL Beryllium<br />

300 μg/mL Cadmium<br />

300 μg/mL Chromium<br />

300 μg/mL Cobalt<br />

300 μg/mL Copper<br />

1,000 μg/mL Lead<br />

200 μg/mL Manganese<br />

50 μg/mL Mercury<br />

300 μg/mL Nickel<br />

20,000 μg/mL Potassium<br />

500 μg/mL Selenium<br />

300 μg/mL Silver<br />

1,000 μg/mL Thallium<br />

300 μg/mL Vanadium<br />

300 μg/mL Zinc<br />

Interference Check Standard, Sb<br />

Matrix/Vol. Concentration of Element Part No. Each (€)<br />

2% HNO 3 /500 mL 1,000 μg/mL Antimony N9300101 101<br />

Interference Check Standard, 5 Elements<br />

Matrix/Vol. Concentration of Element Part No. Each (€)<br />

5% HNO 3 /100 mL 1,200 μg/mL Aluminum N9300208 228<br />

6,000 μg/mL Calcium<br />

5,000 μg/mL Iron<br />

3,000 μg/mL Magnesium<br />

1,000 μg/mL Sodium<br />

Spike Samples<br />

Used to check the effect of sample matrix and<br />

methodology on spike recovery<br />

Add 1.0 mL of spike sample to your aqueous samples<br />

and add 2.0 mL of spike sample to your solid samples<br />

prior to digestion<br />

Matrix/Vol. Concentration of Element Part No. Each (€)<br />

5% HNO 3 /100 mL 200 μg/mL Aluminum N9300230 292<br />

50 μg/mL Antimony<br />

200 μg/mL Arsenic<br />

200 μg/mL Barium<br />

5 μg/mL Beryllium<br />

5 μg/mL Cadmium<br />

20 μg/mL Chromium<br />

50 μg/mL Cobalt<br />

25 μg/mL Copper<br />

100 μg/mL Iron<br />

50 μg/mL Lead<br />

50 μg/mL Manganese<br />

50 μg/mL Nickel<br />

200 μg/mL Selenium<br />

5 μg/mL Silver<br />

200 μg/mL Thallium<br />

50 μg/mL Vanadium<br />

50 μg/mL Zinc<br />

Multi-Element Standards<br />

Multi-element standards were formulated for use with U.S.<br />

EPA methods but can be used with many other methods<br />

successfully. For use in U.S. EPA SW-846, method 6010<br />

section 5.4, as well as method 200.7 section 7.4.<br />

Mixed Standard Solution I<br />

Matrix/Vol. Concentration of Element Part No. Each (€)<br />

2% HNO 3 /100 mL 50 μg/mL Beryllium N9300200 152<br />

150 μg/mL Cadmium<br />

500 μg/mL Lead<br />

100 μg/mL Manganese<br />

200 μg/mL Selenium<br />

150 μg/mL Zinc<br />

Mixed Standard Solution II<br />

Matrix/Vol. Concentration of Element Part No. Each (€)<br />

5% HNO 3 /100 mL 100 μg/mL Barium N9300201 126<br />

100 μg/mL Cobalt<br />

100 μg/mL Copper<br />

10,000 μg/mL Iron<br />

100 μg/mL Vanadium<br />

Mixed Standard Solution III<br />

Matrix/Vol. Concentration of Element Part No. Each (€)<br />

2% HNO 3 /100 mL 500 μg/mL Arsenic N9300202 101<br />

100 μg/mL Molybdenum<br />

100 μg/mL Silicon<br />

234


Standards<br />

PerkinElmer Pure Standards for ICP-OES<br />

Mixed Standard Solution IV<br />

Matrix/Vol. Concentration of Element Part No. Each (€)<br />

5% HNO 3 /100 mL 200 μg/mL Aluminum N9300203 152<br />

1,000 μg/mL Calcium<br />

20 μg/mL Chromium<br />

20 μg/mL Nickel<br />

400 μg/mL Potassium<br />

200 μg/mL Sodium<br />

Mixed Standard Solution V<br />

Matrix/Vol. Concentration of Element Part No. Each (€)<br />

5% HNO 3 /100 mL 200 μg/mL Antimony N9300204 126<br />

100 μg/mL Boron<br />

1,000 μg/mL Magnesium<br />

50 μg/mL Silver<br />

200 μg/mL Thallium<br />

Multi-Element Standard<br />

Matrix/Vol. Concentration of Element Part No. Each (€)<br />

2% HNO 3 /500 mL 50 μg/mL Arsenic N0691579 318<br />

1 μg/mL Barium<br />

10 μg/mL Lanthanum<br />

1 μg/mL Magnesium<br />

10 μg/mL Manganese<br />

10 μg/mL Nickel<br />

50 μg/mL Potassium<br />

10 μg/mL Strontium<br />

10 μg/mL Zinc<br />

Quality Control Standards<br />

Use for trace metal analysis<br />

Check your standard curve<br />

Economical, 100 mL volume<br />

For U.S. EPA method 200.7 and EPA methods manual 600/482-055<br />

“Technical Additions to Methods for Chemical Analysis of Water and Wastes.”<br />

Quality Control Standard, 21 Elements<br />

Matrix/Vol. Concentration of Element Part No. Each (€)<br />

5% HNO 3 /100 mL 100 μg/mL Antimony N9300281 318<br />

100 μg/mL Arsenic<br />

100 μg/mL Beryllium<br />

100 μg/mL Cadmium<br />

100 μg/mL Calcium<br />

100 μg/mL Chromium<br />

100 μg/mL Cobalt<br />

100 μg/mL Copper<br />

100 μg/mL Iron<br />

100 μg/mL Lead<br />

100 μg/mL Lithium<br />

100 μg/mL Magnesium<br />

100 μg/mL Manganese<br />

100 μg/mL Molybdenum<br />

100 μg/mL Nickel<br />

100 μg/mL Selenium<br />

100 μg/mL Strontium<br />

100 μg/mL Thallium<br />

100 μg/mL Titanium<br />

100 μg/mL Vanadium<br />

100 μg/mL Zinc<br />

Quality Control Standard, 7A Elements<br />

Matrix/Vol. Concentration of Element Part No. Each (€)<br />

5% HNO 3 /100 mL 100 μg/mL Aluminum N9300280 152<br />

100 μg/mL Barium<br />

100 μg/mL Boron<br />

1,000 μg/mL Potassium<br />

500 μg/mL Silicon<br />

50 μg/mL Silver<br />

100 μg/mL Sodium<br />

TCLP<br />

Recommended for use in the Toxicity Characteristics<br />

Leachate Procedure, Method 1311.<br />

Matrix/Vol. Concentration of Element Part No. Each (€)<br />

2% HNO 3 /500 mL 25 μg/mL Arsenic N9300241 318<br />

500 μg/mL Barium<br />

5 μg/mL Cadmium<br />

25 μg/mL Chromium<br />

25 μg/mL Lead<br />

5 μg/mL Selenium<br />

25 μg/mL Silver<br />

20 μg/mL Mercury*<br />

* Mercury is supplied in a separate 500 mL bottle.<br />

Standards Inductively Coupled Plasma – OES<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

235


Standards<br />

PerkinElmer Pure Standards for ICP-OES<br />

Inductively Coupled Plasma – OES Standards<br />

Wavecal Solutions<br />

VIS Wavecal Solution<br />

Matrix/Vol. Concentration of Element Part No. Each (€)<br />

2% HNO 3 /250 mL 1 μg/mL Barium N9302946 228<br />

1 μg/mL Calcium<br />

10 μg/mL Lanthanum<br />

10 μg/mL Lithium<br />

10 μg/mL Manganese<br />

50 μg/mL Potassium<br />

10 μg/mL Sodium<br />

10 μg/mL Strontium<br />

UV Wavecal Solution<br />

Correct for calibration changes automatically using the<br />

Wavecal program in your ICP spectrometer’s software.<br />

For use in U.S. EPA SW-846, Method 6010 section 5.6<br />

and method 200.7 section 7.6.1.<br />

Matrix/Vol. Concentration of Element Part No. Each (€)<br />

2% HCI/100 mL 20 μg/mL Arsenic N0681470 24<br />

20 μg/mL Lanthanum<br />

20 μg/mL Lithium<br />

20 μg/mL Manganese<br />

20 μg/mL Molybdenum<br />

20 μg/mL Nickel<br />

100 μg/mL Phosphorus<br />

100 μg/mL Potassium<br />

20 μg/mL Scandium<br />

20 μg/mL Sodium<br />

100 μg/mL Sulfur<br />

2% HCI/500 mL 20 μg/mL Arsenic N0582152 45<br />

20 μg/mL Lanthanum<br />

20 μg/mL Lithium<br />

20 μg/mL Manganese<br />

20 μg/mL Molybdenum<br />

20 μg/mL Nickel<br />

100 μg/mL Phosphorus<br />

100 μg/mL Potassium<br />

20 μg/mL Scandium<br />

20 μg/mL Sodium<br />

100 μg/mL Sulfur<br />

Plasma 40 Wear Metals Wavecal Organic Solution<br />

Before using, dilute to a concentration of 20 μg/mL.<br />

Matrix/Vol. Concentration of Element Part No. Each (€)<br />

75/85 Base Oil/4 oz. 500 μg/mL Aluminum N0681581 547<br />

500 μg/mL Barium<br />

500 μg/mL Boron<br />

500 μg/mL Cadmium<br />

500 μg/mL Calcium<br />

500 μg/mL Chromium<br />

500 μg/mL Copper<br />

500 μg/mL Iron<br />

500 μg/mL Lead<br />

500 μg/mL Lithium<br />

500 μg/mL Magnesium<br />

500 μg/mL Manganese<br />

500 μg/mL Molybdenum<br />

500 μg/mL Nickel<br />

500 μg/mL Phosphorus<br />

500 μg/mL Potassium<br />

500 μg/mL Silicon<br />

500 μg/mL Silver<br />

500 μg/mL Sodium<br />

500 μg/mL Tin<br />

500 μg/mL Titanium<br />

500 μg/mL Vanadium<br />

500 μg/mL Zinc<br />

236


Infrared Spectroscopy<br />

PerkinElmer is the preferred choice for<br />

reliable Infrared (IR) solutions in thousands<br />

of laboratories worldwide. The speed, accuracy<br />

and quality of results deliver proven, long-term cost<br />

savings. With 60+ years of IR experience, PerkinElmer understands each<br />

laboratory’s unique requirements – delivering solutions tailored to your<br />

specific analytical needs.<br />

We offer the industry’s broadest range of IR products.<br />

PerkinElmer instruments are built to the highest ISO-9000<br />

standards, delivering fast, accurate results consistently.<br />

Our continual innovation assures you’re at the<br />

forefront of the industry, and with a wide range<br />

of support packages available, your lab is covered –<br />

from product selection to implementation,<br />

application support and maintenance.


Infrared Spectroscopy<br />

QUICK-FIND INDEX Page #<br />

Autosampler and Sipper Supplies 242<br />

Demountable Cells and Windows 248<br />

Desiccant Kits 240<br />

Evacuable Potassium Bromide Die 258<br />

FT-NIR Cells and Supplies 249<br />

Liquid Sampling Cells<br />

and Supplies 246<br />

Microscopy Sampling<br />

Accessories and Supplies 252<br />

Potassium Bromide Presses 258<br />

Press-N-Lock Demountable<br />

Cell and Windows 250<br />

Reflectance Accessories 255<br />

Sampling Kits and Supplies 257<br />

Sealed Liquid Cells 250<br />

Semi-demountable Cells<br />

and Windows 251<br />

Short-path Demountable<br />

Gas Cells and Windows 245<br />

Solid Sampling Accessories<br />

and Supplies 258<br />

Spectrum Infrared Software 261<br />

Upgrade Kits 265<br />

PerkinElmer offers a wide selection of superior quality products designed to work with<br />

your PerkinElmer instruments. Our precision-designed products deliver the peace of<br />

mind that comes from knowing that you’ll get the results you need.<br />

The Quick Find Index to the left will help you find products fast. For your convenience,<br />

products are alphabetized by category, sub-category, and family. There is also a more<br />

complete Alphabetical INDEX on page 429 and a Part Number INDEX on page 407.<br />

Desiccant Kits<br />

Evacuable Potassium Bromide Die<br />

Manual Hydraulic Press<br />

Desiccant Kits are required for all PerkinElmer FT-IR<br />

spectrophotometers to keep the optical path free from<br />

moisture. It is recommended that the desiccant be replaced<br />

every six months. Please refer to the instrument operator's<br />

manual for correct installation instructions.<br />

Page 240<br />

Prepare 13 mm diameter Kbr pellets of the highest quality<br />

and clarity. The pellet is formed inside an evacuated<br />

chamber and pressed between a highly polished anvil and<br />

plunger. This die is precisely constructed to produce pellets<br />

of uniform quality and will continue to provide many years<br />

of service in your laboratory.<br />

Page 258<br />

This compact and easy-to-operate press is used with the<br />

KBr Die to prepare KBr pellets. The pressure is produced<br />

by operating a pump lever. The Press can also be used with<br />

Heated Platens for applications such as the preparation of<br />

thin polymer films.<br />

Page 258<br />

Universal Demountable Cell<br />

The Universal Demountable Cell is supplied without windows<br />

or spacers. Add Circular Windows (Page 248) to construct a<br />

Demountable Cell. Use Rectangular Windows (Page 251) to<br />

create a semi-demountable cell. A wide variety of window<br />

materials is available to suit your application needs.<br />

Page 248


A History of Innovation...<br />

a Vision for the Future<br />

For more than 60 years, PerkinElmer has<br />

been a world leader in IR spectroscopy,<br />

continually providing innovations designed<br />

to help laboratories produce accurate and<br />

reliable results with ease.<br />

Through industry firsts such as Absolute Virtual Instrument<br />

(AVI) and Atmospheric Vapor Compensation (AVC) and other<br />

patented technologies as well as in-depth IR training and<br />

unmatched service, PerkinElmer continues to deliver Infrared<br />

systems that meet your needs.<br />

Spectrum Spotlight<br />

From the introduction of the industry’s first IR model in<br />

1944 through the pioneering of modular sampling systems,<br />

PerkinElmer has continually advanced the technology of FT-IR<br />

spectroscopy. Our history of innovation continues with the<br />

Spectrum TM family of FT-IR and FT-NIR spectrometers.<br />

Spectrum BX<br />

Spectrum BX Systems are designed<br />

to meet the high validation standards<br />

set by QA/QC, method development<br />

and analytical service laboratories.<br />

All systems in the range offer fast<br />

throughput and rapid access to reliable<br />

and dependable FTIR results, day<br />

in and day out.<br />

Spectrum GX<br />

The Spectrum GX Systems set new<br />

performance standards for sophisticated<br />

research and development work and<br />

routine QA/QC applications. Its top<br />

signal-to-noise performance makes it<br />

the highest performing, research grade<br />

FTIR system available anywhere –<br />

offering unparalleled scope for growth.<br />

With Spectrum GX today’s system<br />

meets tomorrow’s needs.<br />

Spectrum RX<br />

If you work in a busy laboratory and<br />

need a dependable, rugged system<br />

which copes easily with the everyday<br />

challenges of routine applications, you<br />

should use one of our Spectrum RX<br />

Systems. Ideal for QA/QC and educational<br />

environments, they're fast, accurate,<br />

reliable and offer the only genuinely<br />

integrated, preconfigured solution to<br />

get you up and running fast.<br />

Spectrum 100 and Spectrum 100N<br />

Our history of innovation continues with<br />

the reliable, innovative Spectrum 100<br />

spectrometers. Featuring zero-alignment,<br />

easy-to-interchange accessories and<br />

integrated self-test routines, the<br />

Spectrum 100 and 100N systems offer<br />

quick, predictable and reproducible<br />

results – sample after sample.<br />

Spectrum Spotlight<br />

In the field of IR microscopy, PerkinElmer<br />

has been at the forefront since it introduced<br />

the first commercial IR microscope in<br />

1954. A continuous stream of PerkinElmer<br />

innovation has transformed the technique,<br />

made IR microscopy one of the most<br />

potent analytical tools, and established<br />

PerkinElmer FT-IR microscopes as the<br />

industry-standard. The Company’s<br />

breakthroughs in microscopy have set<br />

the benchmark for performance, software<br />

control, and ease of operation.<br />

PerkinElmer’s imaging systems allow large<br />

sample areas to be analyzed in minutes<br />

and seconds, rather than hours. The<br />

Spectrum Spotlight imaging systems’ high<br />

sensitivity allows the smallest samples to<br />

be detected while its IR imaging speed<br />

improves problem-solving time and<br />

redefines maximum measurement areas,<br />

revealing information not previously<br />

available and extending IR analysis to<br />

many new applications.<br />

239


Laboratory Products<br />

Desiccant and Maintenance Kits<br />

Infrared Spectroscopy Laboratory Products<br />

Beamsplitters<br />

KBr Beamsplitter<br />

Replacement Beamsplitter for Spectrum One/100 Systems.<br />

Service installation required, but not included.<br />

Csl Beamsplitter<br />

Replacement Beamsplitter for Spectrum One/100 Systems.<br />

Service installation required, but not included.<br />

Desiccant Kits<br />

Disposable Desiccant Kit Part No. N0171159<br />

These kits are required for all the PerkinElmer FT-IR<br />

Spectrometers to keep the optical path free from moisture.<br />

It is recommended that the desiccant is replaced every<br />

six months. Follow the instructions in the appropriate<br />

instrument manual to install the desiccant.<br />

Disposable Desiccant Kit<br />

User-installable desiccant, includes two desiccant packs.<br />

Four packs (two kits) required for each desiccant change.<br />

For use with Model 1600, Paragon 500, Paragon 1000,<br />

Spectrum TM 1000, Spectrum RX, and Spectrum BX. Also for<br />

Spectrum GX, Spectrum 2000, System 2000, Spectrum One,<br />

and Spectrum One NTS. Six packs<br />

(three kits) required for use with<br />

Part No. Each (€)<br />

Spectrum 100 and Spectrum 100N. N0171159 39<br />

Rechargeable Desiccant Kit for Spectrum One and<br />

Spectrum One NTS<br />

Includes four desiccant packs, two to<br />

use in the instrument and two spares<br />

for recharging.<br />

Part No.<br />

Part No.<br />

Each (€)<br />

L1200214 4026<br />

Part No.<br />

Each (€)<br />

L1200216 7200<br />

Each (€)<br />

L1200219 394<br />

Rechargeable Desiccant Kit for Spectrum<br />

1000/Spectrum RX/Spectrum BX/ Paragon<br />

500/Paragon 1000/Model 1600<br />

Includes one desiccant pack. One pack<br />

required for each desiccant change.<br />

Rechargeable Desiccant Kit for Model 1700<br />

Includes one desiccant pack. One pack<br />

required for each desiccant change.<br />

Rechargeable Desiccant Kit for Spectrum GX/<br />

Spectrum 2000/System 2000 FT-IR Optical Units<br />

Includes one desiccant pack. One pack<br />

required for each desiccant change.<br />

Rechargeable Desiccant Kit for Spectrum GX/<br />

Spectrum 2000 Detector Area/System 2000<br />

Includes one desiccant pack. One pack<br />

required for each desiccant change.<br />

Maintenance Kits<br />

Spectrum One NTS Maintenance Kit<br />

Includes spare Source Lamp and<br />

Desiccant recommended for 6-12<br />

monthly maintenance operations.<br />

Spectrum IdentiCheck Maintenance Kit<br />

Includes spare source lamp<br />

and desiccant.<br />

Laser Head (HeNe) and Laser Power Supply<br />

User-installable spare for<br />

Spectrum One/100 and Spectrum<br />

One NTS/100N systems.<br />

Part No.<br />

Each (€)<br />

L1180480 197<br />

Part No.<br />

Each (€)<br />

L1160333 347<br />

Part No.<br />

Each (€)<br />

04994506 307<br />

Part No.<br />

Each (€)<br />

04994507 574<br />

Part No.<br />

Part No.<br />

Each (€)<br />

L1180486 221<br />

Part No.<br />

Each (€)<br />

L1240097 185<br />

Each (€)<br />

L1200253 1268<br />

240


Laboratory Products<br />

Source Lamps and Standards<br />

Source Lamps<br />

TG/IR and GC/IR Supplies<br />

Source Lamp for Spectrum One NTS/100N<br />

User-installable spare for<br />

Spectrum One NTS/100N Systems.<br />

Source Lamp for Spectrum One/100<br />

User-installable spare for<br />

Spectrum One/100 Systems.<br />

Standards<br />

Spectralon Reference Standards Set (Calibrated)<br />

For use with the Spectrum One NTS/100N Reflectance<br />

Accessory and the IdentiCheck Reflectance Accessory.<br />

Includes calibrated standards for<br />

reflective values of 99, 75, 50, and 2%.<br />

Part No. Each (€)<br />

L1181322 5400<br />

Thin Test Films<br />

These thin polymer films, sealed in cardboard mounts,<br />

serve as easy-to-use standards which are stable with time.<br />

Use them to check frequency accuracy and to monitor any<br />

changes in the overall performance of the spectrometer.<br />

Mounted films of polystyrene and Teflon ® are available,<br />

0.038 and 0.05 mm thick, respectively.<br />

Polystyrene Test Film<br />

0.038 mm, mounted.<br />

Teflon Test Film<br />

0.05 mm.<br />

Part No.<br />

Each (€)<br />

L1240098 179<br />

Part No.<br />

Each (€)<br />

L1200406 1208<br />

Part No.<br />

Each (€)<br />

L1202057 16<br />

Part No.<br />

Each (€)<br />

L1181056 5<br />

The removable inert linings of the cell and transfer<br />

line can be replaced with the spares supplied with the<br />

TG/IR Maintenance Kit. Potassium bromide and zinc<br />

selenide replacement infrared windows for the gas cell<br />

are also available.<br />

TG/IR Maintenance Kit<br />

Includes cell inner body, heater line<br />

inner tube (1,500 mm), selection<br />

of O-Rings, and fuses.<br />

KBr Windows for Gas Cell<br />

ZnSe Windows for Gas Cell<br />

PEEK Cell Liner<br />

Heated Line Inner Tube<br />

Test Mix-FID for GC/IR<br />

Part No.<br />

Each (€)<br />

L1362300 365<br />

Part No.<br />

Each (€)<br />

04978581 606<br />

Part No.<br />

Each (€)<br />

04978582 1471<br />

Part No.<br />

Each (€)<br />

L1362307 167<br />

Part No.<br />

Each (€)<br />

04978590 161<br />

Part No.<br />

Each (€)<br />

L4831520 57<br />

Laboratory Products Infrared Spectroscopy<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

241


Infrared Spectroscopy Sampling Accessories and Supplies<br />

Sampling Accessories and Supplies<br />

Autosampler and Sipper Supplies<br />

Autosampler Accessories<br />

Drip Tray for FT-NIR<br />

Flush Port Lid O-Ring for FT-NIR<br />

Fuses (2A time delay) for FT-NIR<br />

Insulation Block<br />

for Spectrum OilExpress<br />

Non-Return Valve for FT-NIR<br />

Sample Probe<br />

for Spectrum OilExpress<br />

Solvent Bottle and Cap (drilled)<br />

for FT-IR and FT-NIR<br />

Solvent Filter for FT-NIR<br />

Autosampler Flowcells,<br />

Windows, and Supplies<br />

FT-IR Flowcell<br />

0.1 mm pathlength, wedged Spacer,<br />

ZnSe Windows (one grooved),<br />

and three ports.<br />

OilExpress Flowcell<br />

0.1 mm pathlength, wedged Spacer,<br />

ZnSe Windows (one grooved), and<br />

two ports. Optimized for the sampling<br />

L1191202 2201<br />

of viscous fluids and to reduce interference fringes.<br />

ZnSe Windows for FT-IR and<br />

Spectrum OilExpress Flowcell<br />

Fitted to ensure moisture resistance.<br />

Part No.<br />

Each (€)<br />

L1191014 132<br />

Part No.<br />

Each (€)<br />

09921037 2<br />

Part No.<br />

Each (€)<br />

04970839 1<br />

Part No.<br />

Each (€)<br />

L1200558 261<br />

Part No.<br />

Part No.<br />

Each (€)<br />

L1200555 969<br />

Part No.<br />

Each (€)<br />

L1195019 62<br />

Part No.<br />

Each (€)<br />

04970573 114<br />

Each (€)<br />

09903615 68<br />

Part No.<br />

Each (€)<br />

L1191080 2201<br />

Part No.<br />

Part No.<br />

Each (€)<br />

Each (€)<br />

L1191081 1256<br />

Gaskets and Spacers for FT-IR<br />

and Spectrum OilExpress Flowcell<br />

FT-NIR Flowcell<br />

1 mm pathlength, quartz, and 2-ports.<br />

Gasket Set for FT-NIR Flowcell -<br />

1 mm 2-port<br />

(pkg. 10)<br />

Gasket Set for FT-NIR Flowcell -<br />

0.5 mm 2-port<br />

(pkg. 10)<br />

Autosampler Sample Cassettes<br />

and Vials for FT-IR and FT-NIR<br />

Additional sample cassettes can be purchased for the FT-IR<br />

Liquid Autosampler. For greater productivity, one cassette<br />

can be used for analysis while others are being loaded.<br />

Autosampler Vial Cassette<br />

Holds 50 tubes, 16.8 x 67 mm.<br />

Autosampler Vial Cassette<br />

Holds 100 tubes, 16.8 x 67 mm.<br />

Plastic Autosampler Vials<br />

for FT-IR and FT-NIR<br />

Pack of 1000 vials<br />

Caps for FT-NIR Glass Vials<br />

Pack of 144 caps<br />

Septa for FT-NIR Glass Vials<br />

Pack of 100 Septa<br />

Part No.<br />

Each (€)<br />

L1191082 61<br />

Part No.<br />

Each (€)<br />

L1191207 1531<br />

Part No.<br />

Each (€)<br />

L1191099 132<br />

Part No.<br />

Each (€)<br />

L1191113 132<br />

Part No.<br />

Each (€)<br />

L1191021 2081<br />

Part No.<br />

Each (€)<br />

L1191018 3002<br />

Part No.<br />

Each (€)<br />

L1191079 132<br />

Part No.<br />

Each (€)<br />

L1191210 85<br />

Part No.<br />

Each (€)<br />

L1191211 74<br />

242


Autosampler Sample Racks<br />

for Spectrum OilExpress<br />

Additional sample racks can be purchased for the Spectrum<br />

OilExpress Autosampler. There is a choice of sample test<br />

tube or sample bottle racks depending on the sampling<br />

requirements. Also, for greater productivity, one rack can<br />

be used for analysis while others are being loaded.<br />

Autosampler Oil Bottle Rack<br />

Additional 30-position, 4 oz bottle rack to allow the<br />

preparation of the next rack while a run is in progress.<br />

Allows sample presentation in standard sample<br />

collection vessels, reducing the amount<br />

of sample preparation required.<br />

Part No. Each (€)<br />

L1200551 981<br />

Autosampler Test Tube Racks 16 x 6<br />

Allows interchangeable sampling<br />

between test-tube vials and<br />

4 oz bottles.<br />

Autosampler Syringe<br />

and Needle Supplies<br />

Needle for FT-IR and FT-NIR<br />

Needle O-Ring for FT-IR and FT-NIR<br />

(pkg. 5)<br />

Needle Spring for FT-IR and FT-NIR<br />

(pkg. 5)<br />

10 mL Syringe with Plunger<br />

for Spectrum OilExpress<br />

Seal Kit for Spectrum OilExpress<br />

Contains four user replaceable<br />

syringe piston noses.<br />

Lubrication Kit for Syringe Pump<br />

Screw Drive for Spectrum OilExpress<br />

Syringe Clamps for Spectrum OilExpress<br />

Clamps to prevent Syringe barrel<br />

from moving.<br />

Part No.<br />

Sampling Accessories and Supplies<br />

Each (€)<br />

L1200589 921<br />

Part No.<br />

Each (€)<br />

L1191031 47<br />

Part No.<br />

Each (€)<br />

L1003012 3<br />

Part No.<br />

Each (€)<br />

L1003018 12<br />

Part No.<br />

Each (€)<br />

L1200552 137<br />

Part No.<br />

Each (€)<br />

L1200553 66<br />

Part No.<br />

Each (€)<br />

L1200559 33<br />

Part No.<br />

Each (€)<br />

L1200574 80<br />

Autosampler and Sipper Supplies<br />

Autosampler Tubing<br />

Peristaltic Pump Tubing<br />

Length Material Application Part No. Each(€)<br />

3 m Tygon ® 4040A FT-IR, FT-NIR, L1191015 62<br />

OilExpress<br />

3 m Tygon R-3603 FT-NIR 02507999 9<br />

3 m PharMed TM FT-NIR L1191114 35<br />

Waste Tubing<br />

Application Part No. Each(€)<br />

OilExpress L1200560 27<br />

FT-NIR 02508065 10<br />

Tubing for Needle and Connections<br />

in Front Panel for FT-IR and FT-NIR<br />

1 m, Teflon ® Tube, 2 mm i.d.<br />

Ferrules for Ends of Teflon<br />

Tubing for FT-IR and FT-NIR<br />

For front panel and flowcell<br />

connections, 1/8 in. Tefzel. (pkg. 5)<br />

Nuts for Ends of Teflon<br />

Tubing for FT-IR and FT-NIR<br />

For front panel and flowcell<br />

connections, 1/8 in. (pkg. 5)<br />

Tube Flanging Kit<br />

Sample Needle Tubing<br />

for Spectrum OilExpress<br />

Flowcell to Syringe Tubing<br />

for Spectrum OilExpress<br />

Solvent to Syringe Tubing<br />

for Spectrum OilExpress<br />

(pkg. 2)<br />

Injection/Transfer Port to Flowcell<br />

Tubing for Spectrum OilExpress<br />

Part No.<br />

Each (€)<br />

02508063 10<br />

Part No.<br />

Part No.<br />

Part No.<br />

Each (€)<br />

09923337 263<br />

Part No.<br />

Each (€)<br />

L1200587 44<br />

Part No.<br />

Each (€)<br />

L1200588 49<br />

Part No.<br />

Each (€)<br />

L1200556 44<br />

Part No.<br />

Each (€)<br />

L1003021 18<br />

Each (€)<br />

L1003020 18<br />

Each (€)<br />

L1200557 44<br />

Sampling Accessories and Supplies Infrared Spectroscopy<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

243


Infrared Spectroscopy Sampling Accessories and Supplies<br />

Sampling Accessories and Supplies<br />

Autosampler and Sipper Supplies<br />

Sipper Cells and Windows<br />

for the Spectrum One/100<br />

Demountable Sipper Cell Kit – No Windows<br />

Allows cells to be made up with different window materials<br />

and pathlengths to suit specific applications. Choose from the<br />

windows and spacers listed below.<br />

Part No. Each (€)<br />

Sipper Cell Windows<br />

For use with the Demountable Sipper Cell Kit. Includes one<br />

grooved and one plain window.<br />

Window Material Part No. Each (€)<br />

KBr L1200308 610<br />

CaF 2 L1200309 803<br />

BaF 2 L1200310 829<br />

Sipper Cell Spacers<br />

For use with the Demountable Sipper Cell Kit.<br />

Width Part No. Each (€)<br />

50 Microns L1201904 14<br />

100 Microns L1201905 14<br />

Sipper Cells and Windows<br />

for the Spectrum One NTS/100N<br />

Quartz Sipper Cell Inlet Window<br />

Quartz Sipper Cell Plain Window<br />

Cell Spacer 0.5 mm<br />

L1200306 217<br />

Part No.<br />

Each (€)<br />

L1202715 234<br />

Part No.<br />

Each (€)<br />

L1202716 234<br />

Part No.<br />

Each (€)<br />

L1201231 2<br />

Sipper Supplies<br />

Sipper Pump Tubing<br />

Complete with hose barb connectors.<br />

Material Part No. Each (€)<br />

Viton L1202006 13<br />

Autoprene L1202035 13<br />

Silicone L1202036 13<br />

Tygon ® L1202037 13<br />

Teflon Tubing (1 m)<br />

Used for internal connection<br />

between Sipper pump and cell.<br />

Ferrule (Tefzel)<br />

Used for Sipper tube connection. (pkg. 5)<br />

Nut Flange for Ferrule<br />

Used for Sipper tube connection. (pkg. 5)<br />

Filter<br />

Used for filtering solid particulates<br />

from the liquid sample.<br />

Tablet Autosampler Supplies<br />

Part No.<br />

Each (€)<br />

02508063 10<br />

Part No.<br />

Each (€)<br />

L1003021 18<br />

Part No.<br />

Each (€)<br />

L1003020 18<br />

Part No.<br />

Each (€)<br />

L1201989 167<br />

The Spectrum FT-NIR Systems Tablet Autosampler is ideal<br />

for tablet identification, tablet assays, and content uniformity<br />

of tablet batches. It can also be used as a Near Infrared<br />

Reflectance Accessory for analyzing a wide range of sample<br />

types in various containers.<br />

244


Custom Tablet Moulds Resin Kit<br />

Includes resin, accelerator, and release agent to make<br />

approximately 200 custom moulds.<br />

Part No. Each (€)<br />

Tablet Setting Pin<br />

Size Pkg. Part No. Each (€)<br />

6 mm 5 L1241555 18<br />

4 mm 5 L1241559 18<br />

Tablet Mould<br />

Size Pkg. Part No. Each (€)<br />

6 mm 5 L1241557 6<br />

4 mm 5 L1241558 6<br />

Tablet Mould Base<br />

(pkg. 5)<br />

Disposable Syringe<br />

Size Pkg. Part No. Each (€)<br />

1 mm 100 09200010 300<br />

10 mm 100 09200011 345<br />

Syringe Nozzle<br />

(pkg. 50)<br />

Tablet Holder<br />

Size Pkg. Part No. Each (€)<br />

8 mm 5 L1241571 7<br />

9 mm 5 L1241572 7<br />

10 mm 5 L1241573 7<br />

11 mm 5 L1241574 7<br />

12 mm 5 L1241575 15<br />

4 mL Glass Vial with Cap,<br />

15 x 45 mm<br />

(pkg. 100)<br />

Beaker, 100 mL Tri-Corner<br />

(pkg. 100)<br />

Spatula<br />

(pkg. 3)<br />

Sampling Accessories and Supplies<br />

L1245024 371<br />

Part No.<br />

Each (€)<br />

L1241556 49<br />

Part No.<br />

Each (€)<br />

09200013 187<br />

Part No.<br />

Each (€)<br />

L9001029 78<br />

Part No.<br />

Each (€)<br />

09200012 102<br />

Part No.<br />

Each (€)<br />

09200017 33<br />

Autosampler and Gas Sampling Supplies<br />

Short-path Demountable<br />

Gas Cells and Windows<br />

PerkinElmer offers Short-path Demountable Cells to<br />

monitor air pollutants, study vapor phase transitions in<br />

gas molecules, and quantify impurities in gas samples.<br />

These 10 cm cells have been designed for use on all<br />

PerkinElmer infrared instruments.<br />

Removable Windows for Easy Cleaning<br />

Reactive gases may fog or attack the window material, but<br />

the windows can be removed easily and repolished.<br />

Stopcocks for filling and purging the cell are an integral<br />

part of the cell body. The cells should not be subjected to<br />

pressures of more than one atmosphere. The cell has a<br />

volume of approximately 120 mL.<br />

The cell is supplied with windows, and spare windows can<br />

be ordered separately. A Universal 10 cm Gas Cell Mount is<br />

required to mount the accessory in the sample slide of the<br />

instrument and must be ordered separately.<br />

10 cm Short-path Demountable<br />

Gas Cells with Windows<br />

Window Material Part No. Each (€)<br />

NaCl 51000634 546<br />

KBr 51000636 616<br />

CaF 2 51000638 616<br />

47 mm Replacement Windows<br />

Window Material Qty. Part No. Each (€)<br />

NaCl 2 51000635 176<br />

KBr 2 51000637 301<br />

CaF 2 2 51000639 667<br />

Universal 10 cm Gas Cell Mount<br />

Gaskets for 10 cm Gas Cells<br />

Part No.<br />

Each (€)<br />

51000817 103<br />

Part No.<br />

Each (€)<br />

51012725 51<br />

Sampling Accessories and Supplies Infrared Spectroscopy<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

245


Sampling Accessories and Supplies<br />

Liquid Sampling Cells and Supplies<br />

PerkinElmer Liquid Sampling Cells<br />

and Window Materials<br />

PerkinElmer offers a wide selection<br />

of liquid sampling cells and<br />

window materials.<br />

PerkinElmer offers a versatile product line of liquid<br />

sampling cells which utilize a specially designed<br />

Universal mount suitable for both FT-IR and dispersive<br />

instruments, and a wide variety of high-quality window<br />

materials to meet your analytical needs. These windows<br />

are polished to precise tolerances of flatness.<br />

The first criteria to consider when selecting a<br />

window material is the wavelength range over which<br />

the spectrum must be measured.<br />

Sealed Cell and Demountable Cell<br />

Other important considerations include solubility,<br />

reactivity, and the refractive index of the window<br />

material with respect to the sample. Sometimes<br />

mechanical and thermal characteristics may also<br />

be important.<br />

Solubility<br />

Transmission Refractive Index G/100 G H 2 0<br />

Window Material Refractive Range μm cm -1 at 1000 cm -1 at 20 °C<br />

Sodium Chloride, NaCl 0.25 - 16 40,000 - 625 1.49 36.0<br />

Potassium Bromide, KBr 0.25 - 26 40,000 - 385 1.52 65.2<br />

Potassium Chloride, KCl 0.25 - 20 40,000 - 500 1.46 34.7<br />

Cesium Iodide, CsI 0.30 - 50 33,000 - 200 1.74 160.0 (at 61 °C)<br />

Fused Silica, Si0 2 0.20 - 4 50,000 - 2,500 1.42 (at 3,333 cm -1 ) Insoluble<br />

Calcium Fluoride, CaF 2 0.20 - 9 50,000 - 1,100 1.39 (at 2,000 cm -1 ) 1.51 x 10 -3<br />

Barium Fluoride, BaF 2 0.20 - 13 50,000 - 770 1.42 0.12 (at 25 °C)<br />

Thallium Bromide-Iodide, KRS-5 0.60 - 40 16,600 - 250 2.37 < 4.76 x 10 -2<br />

Silver Bromide, AgBr 0.50 - 35 20,000 - 285 2.00 12 x 10 -6<br />

Zinc Sulfide, ZnS (Cleartran) 1.0 - 14 10,000 - 715 2.20 Insoluble<br />

Zinc Selenide, ZnSe (Irtran-4) 1.0 - 19.5 10,000 - 515 2.41 Insoluble<br />

Polyethylene (high-density) 16 - 333 625 - 30 1.54 (at 5,000 cm -1 ) Insoluble<br />

246


Sampling Accessories and Supplies<br />

Liquid Sampling Cells and Supplies<br />

PerkinElmer offers a variety of cell<br />

options for analyzing liquid samples.<br />

Liquids are traditionally analyzed as thin films in cells. A cell consists<br />

of two FT-IR transparent windows. A Teflon spacer is generally<br />

used to produce a film of the desired thickness or pathlength.<br />

Demountable Cells – using circular windows, the Universal<br />

Demountable Cell is ideal for use with mulls, capillary films,<br />

cast films and very viscous liquids.<br />

Semi-demountable Cells – using rectangular windows, the Universal<br />

Demountable Cell is designed for use with high viscosity liquids<br />

or mull samples.<br />

Sealed Liquid Cells – designed as a preassembled, integral unit,<br />

Sealed Liquid Cells are great for highly volatile samples and<br />

quantitative analysis.<br />

Press-N-Lock Demountable Cells – eliminates the need for nuts, springs,<br />

and bolts to keep the cell together.<br />

Press-N-Lock Demountable Cell Part No. N9302642<br />

PerkinElmer cells feature both rugged construction and flexibility.<br />

All can easily be cleaned for re-use and, depending on the cell you<br />

choose, can be disassembled so that cell windows can be cleaned<br />

and polished regularly.<br />

PerkinElmer also offers<br />

FT-NIR Cells which are<br />

available in a wide range<br />

of configurations and<br />

lightpaths.<br />

The following information may be helpful in selecting window materials:<br />

Sodium Chloride (NaCl)<br />

NaCl is one of the most versatile window materials available, due to<br />

its spectral range and low cost. Samples should not contain water<br />

because NaCl is hygroscopic. This will cause the windows to fog and<br />

become unusable. Store NaCl cells in a desiccator when not in use.<br />

NaCl withstands mechanical stress and can be used up to 400 °C.<br />

Potassium Bromide (KBr)<br />

KBr has a slightly wider spectral range than NaCl but is more<br />

hygroscopic. Although able to provide good resistance to mechanical<br />

shock, KBr is easily cleaved. KBr can be used up to 300 °C.<br />

Cesium Iodide (CsI)<br />

CsI has an extended spectral range relative to NaCl and KBr.<br />

However, CsI is very hygroscopic and is soft material that can be<br />

scratched easily. CsI does not cleave, reacts with many organic<br />

compounds, and can withstand rapid temperature changes.<br />

Calcium Fluoride (CaF 2 )<br />

CaF 2 is extremely hard and stable. CaF 2 is not significantly affected<br />

by moisture and does not fog. While resistant to most acids and<br />

bases, CaF 2 should not be used with ammonium salts.<br />

Barium Fluoride (BaF 2 )<br />

BaF 2 is a relatively hard material, similar to CaF 2 . Though less<br />

resistant to water than CaF 2 , BaF 2 has a wider spectral range. The<br />

useful temperature range extends to 500 °C. Also, BaF 2 should not<br />

be used with ammonium salts.<br />

Thallium Bromide-Iodide (KRS-5)<br />

KRS-5 has a broad spectral range and a high refractive index,<br />

making it ideal for internal reflectance accessories. KRS-5 is<br />

slightly soluble in water and bases but insoluble in acids; KRS-5<br />

is toxic and should not be repolished.<br />

Silver Bromide (AgBr)<br />

AgBr is easily scratched and has a tendency to cold flow at room<br />

temperature. Although only minimally degraded by water, AgBr will<br />

corrode after prolonged contact with moisture and metals. Avoid<br />

exposure to ultraviolet lights, as the crystal has a tendency to darken.<br />

Zinc Sulfide (Cleartran TM )<br />

Cleartran is relatively hard and has a high refractive index. Cleartran<br />

is insoluble in water but is slightly attacked by acids and strong bases.<br />

Zinc Selenide (Irtran-4 TM )<br />

Irtran-4 is similar to Cleartran except that it is somewhat softer<br />

and more easily scratched. Irtran-4 is used in total reflectance<br />

accessories because of its high refractive index.<br />

Fused Silica (SiO 2 )<br />

Infrared grade SiO 2 has a useful spectral range extending into<br />

the near infrared. Although insoluble in water, SiO 2 is resistant<br />

to mechanical and thermal stress.<br />

Polyethylene<br />

Polyethylene is a window material for the far infrared. Although it<br />

has a broad absorption band at about 70 cm -1 , polyethylene can be<br />

used to 10 cm -1 . The principal disadvantage with polyethylene is<br />

that its lack of rigidity makes cell thickness difficult to control. In<br />

addition, polyethylene cell windows are difficult to clean.<br />

FT-NIR Cells<br />

www.perkinelmer.com/<strong>supplies</strong> 247


Infrared Spectroscopy Sampling Accessories and Supplies<br />

Sampling Accessories and Supplies<br />

Liquid Sampling Cells and Supplies<br />

Demountable Cell<br />

Crystal Polishing Kit<br />

Crystal Polishing Kit<br />

Fogged windows are quickly restored to perfect condition<br />

with the infrared crystal polishing kit. The kit contains<br />

everything necessary to repolish sodium chloride,<br />

potassium bromide, or cesium iodide windows, and<br />

includes a smoothing lap, polishing rouge, a sponge,<br />

an optical flat, a Selvyt cloth, and a booklet describing<br />

the repolishing technique. Special self-adhesive Selvyts<br />

that stick to the polishing lap are also<br />

supplied; this keeps the Selvyt flat and Part No. Each (€)<br />

makes replacement quick and simple.<br />

51001188 342<br />

Replacement Parts for the Crystal Polishing Kit<br />

The following parts are included in the Crystal Polishing<br />

Kit, but are also available separately:<br />

Description Part No. Each (€)<br />

Selvyt Cloth (pkg. 5) 51001324 90<br />

Glass Grinding Lap 51001325 73<br />

Optical Lap 51001326 73<br />

Cleaning Sponge (pkg. 2) 51001327 51<br />

Tin Polishing Rouge, 56 g 51001328 94<br />

Polishing Lap Glass Plate 51001329 51<br />

Demountable Cells and Windows<br />

For Mulls, Capillary Films, Cast Films,<br />

and Very Viscous Liquids<br />

Circular windows are used to<br />

construct a demountable cell<br />

where the sample is placed on<br />

one window and the second<br />

window is pressed lightly on<br />

top of the first. Spacers of various<br />

thicknesses can be used to vary<br />

the cell pathlength.<br />

Universal Demountable<br />

Cell Mount<br />

Includes top and back plates.<br />

The Universal Demountable Cell<br />

is supplied without windows or<br />

spacers – circular windows and<br />

spacers should be ordered<br />

separately. A thicknesscompensating<br />

spacer is required<br />

for 2 mm thick windows. The<br />

windows are demountable and<br />

can be easily changed and<br />

repolished when necessary.<br />

Part No.<br />

Each (€)<br />

L1270986 299<br />

Demountable Cell Parts<br />

Components Part No. Each (€)<br />

1<br />

Back Plate<br />

23 Window Aligner 04821132 12<br />

31 Neoprene TM Gasket L1270512 15<br />

43 Circular Window (see product listing below)<br />

53 Spacer (see product listing below)<br />

63 Top Plate<br />

74 Teflon ® Plugs (pkg. 6) 04821008 6<br />

82 Quick Release Nut 04821131 14<br />

1 2 3 4 5 4<br />

Circular Demountable Cell Windows (Pair)<br />

Window Material Diameter Thickness Part No. Each (€)<br />

Sodium Chloride 25 mm 4 mm L1271102 82<br />

Potassium Bromide 25 mm 4 mm L1271202 136<br />

Calcium Fluoride 25 mm 4 mm L1271602 617<br />

Barium Fluoride 25 mm 4 mm L1272002 660<br />

Thallium Bomide-Iodide 25 mm 4 mm L1270665 688<br />

Silver Bromide 25 mm 2 mm L1272102 518<br />

Zinc Selenide 25 mm 2 mm L1270766 919<br />

Circular Spacers for Circular<br />

Demountable Cell Windows<br />

Spacer Material Thickness Qty. Part No. Each (€)<br />

Lead 0.025 mm 10 L1271250 72<br />

Teflon* 0.05 mm 10 51001135 59<br />

Teflon* 0.1 mm 6 51001137 59<br />

Teflon* 0.2 mm 3 51001140 59<br />

Teflon* 0.5 mm 3 51001141 63<br />

* Teflon spacers can be used for the analysis of less viscous samples.<br />

6<br />

7<br />

8<br />

248


FT-NIR Cells and Supplies<br />

PerkinElmer offers a<br />

comprehensive range of FT-NIR<br />

Cells, cell holders, and <strong>supplies</strong>.<br />

The range includes Cylindrical<br />

Cells, Rectangular Cells, Semimicro<br />

Cells, and Micro Cells.<br />

These cells are suitable for use<br />

with all PerkinElmer FT-NIR<br />

Spectrometers.<br />

FT-NIR Cylindrical Cells<br />

Material Lightpath mm Qty. Part No. Each (€)<br />

Fused Silica 2 1 L1181301 231<br />

Fused Silica 5 1 L1181302 266<br />

Quartz Suprasil 300 10 1 B0631099 97<br />

Quartz Suprasil 300 20 1 B0631100 97<br />

Quartz Suprasil 300 50 1 B0631101 129<br />

Quartz Suprasil 300 100 1 B0631102 143<br />

FT-NIR Cylindrical Cell Holders<br />

Lightpath mm Qty. Part No. Each (€)<br />

10 1 L1181303 257<br />

50 1 N9302620 159<br />

100 1 N9302640 133<br />

FT-NIR Rectangular Cells<br />

Lightpath<br />

Material mm Cap Qty. Part No. Each (€)<br />

Quartz Suprasil 300 1 Lid 2 B0631013 327<br />

Fused Silica 2 Lid 1 L1181304 121<br />

5 Lid 2 B0631014 177<br />

10 Lid 2 B0631015 160<br />

20 Lid 2 B0631016 332<br />

Quartz Suprasil 300 50 Lid 1 B0631017 218<br />

100 Lid 1 B0631018 200<br />

1 Stopper 2 B0631031 399<br />

5 Stopper 2 B0631032 356<br />

10 Stopper 2 B0631033 179<br />

20 Stopper 2 B0631034 200<br />

50 Stopper 2 B0631035 250<br />

100 Stopper 1 B0631036 467<br />

Quartz Infrasil 5 Stopper 2 52001539 187<br />

50 mm FT-NIR Rectangular<br />

Cell Holder<br />

Semi-Micro Rectangular Cells<br />

Part No.<br />

Lightpath mm Cap Qty. Part No. Each (€)<br />

10 Lid 2 B0631051 451<br />

20 Lid 2 B0631045 422<br />

5 Stopper 2 B0631065 489<br />

10 Stopper 2 B0631066 489<br />

20 Stopper 2 B0631060 385<br />

Sampling Accessories and Supplies<br />

Each (€)<br />

02200550 103<br />

Liquid Sampling Cells and Supplies<br />

Micro Rectangular Cell<br />

Material Lightpath mm Cap Qty. Part No. Each (€)<br />

Quartz Suprasil 300 10 Stopper 2 B0631078 709<br />

Spare Lids and Stoppers<br />

Description Part No. Each (€)<br />

5 mm PTFE Lid B0631145 4<br />

10 mm PTFE Lid B0631129 2<br />

Stopper, NS7 Fitting, PTFE B0631128 3<br />

Stopper, PTFE B0631149 3<br />

FT-NIR FT-Raman Sampling Accessory Kit<br />

Developed to ensure that you obtain the best possible spectrum<br />

for virtually any sample, the kit is comprised of four sampling<br />

devices designed to be used interchangeably without<br />

realignment between samples. These accessories provide<br />

reproducible sample positioning essential for quantitative<br />

studies. Each accessory is matched with the Raman collection<br />

optics and will enhance the signal-to-noise by factors of 2 to 4.<br />

Compatible with the 1700X Series FT-NIR FT-Raman<br />

spectrometer, the System 2000R,<br />

Spectrum 2000R, and the<br />

Spectrum GX Raman.<br />

Part No.<br />

L1304040<br />

Each (€)<br />

3493<br />

Low-Volume Liquid Spheres<br />

For use with the FT-Raman Sampling<br />

Accessory. (pkg. 50)<br />

FT-NIR Disposable Cells and Holders<br />

for the Spectrum One NTS/100N<br />

Disposable Snap-Cells<br />

Fully assembled for the convenient analysis of liquid samples.<br />

Includes cell holder, Snap-cells, glass cell windows, and a<br />

1 mL pipette for sample introduction. Pathlength ca 0.5 mm.<br />

Snap-Cell (Qty.) Glass Cell Windows (Qty.) Part No. Each (€)<br />

Pack of 5 10 L1240056 32<br />

Pack of 100 200 L1240057 592<br />

Molded Flexible Cuvette Holder<br />

in Transmission Cell Slide<br />

For rectangular cuvettes of pathlength<br />

0.5 - 20 mm or ca 11 mm diameter<br />

disposable vials.<br />

Part No.<br />

Part No.<br />

Each (€)<br />

L1871106 437<br />

Each (€)<br />

L1240055 35<br />

Sampling Accessories and Supplies Infrared Spectroscopy<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

249


Infrared Spectroscopy Sampling Accessories and Supplies<br />

Sealed Cell<br />

Sampling Accessories and Supplies<br />

Liquid Sampling Cells and Supplies<br />

Press-N-Lock Demountable<br />

Cell and Windows<br />

For Simple Analysis of Mulls, Smears, and Viscous Films<br />

The Press-N-Lock Demountable Cell lets you analyze<br />

mulls, smears, viscous films, etc., without the use of<br />

nuts, springs, or bolts to keep the cell together. You<br />

can use this cell on any PerkinElmer FT-IR<br />

spectrometer. The cell consists of a<br />

backplate with a Viton O-Ring that<br />

lets you slip the cover on and off<br />

with ease.<br />

Press-N-Lock Demountable Cell<br />

Press-N-Lock Cell O-Rings<br />

25 mm (pkg. 12).<br />

Press-N-Lock Demountable Cell Windows (Pair)<br />

Window Material Diameter Thickness Part No. Each (€)<br />

NaCl 25 mm 4 mm L1271102 82<br />

KBr 25 mm 4 mm L1271202 136<br />

BaF 2 25 mm 4 mm L1272002 660<br />

ZnSe 25 mm 2 mm L1270766 919<br />

CaF 2 25 mm 4 mm L1271602 617<br />

Sealed Liquid Cells<br />

Part No.<br />

For Highly Volatile Samples and Quantitative Analysis<br />

Each (€)<br />

N9302642 123<br />

Part No.<br />

Each (€)<br />

N9302643 44<br />

The sealed liquid cells have a corrosion-resistant construction,<br />

making them ideal for highly volatile samples. Each sealed<br />

liquid cell has a precise pathlength which is calibrated using<br />

the interference pattern generated by an empty cell in the<br />

beam of a spectrometer. The sealed liquid cells are ideal<br />

for quantitative analysis where you require an accurate<br />

reproducible cell thickness. These cells use a lead spacer<br />

which is amalgamated to the window<br />

material. The resultant bond forms a<br />

good leak-free seal which is effective<br />

in preventing evaporation and loss of<br />

sample. You can fill or empty liquid<br />

samples easily. The sealed liquid cell<br />

is an integral unit and cannot<br />

be disassembled.<br />

Rugged construction<br />

Easy to fill and clean<br />

Leak-free operation<br />

Calibrated for quantitative analysis<br />

Usable on all PerkinElmer FT-IR spectrometers<br />

Holds Highly Volatile Samples<br />

The amalgam seal between the windows will hold even low<br />

boiling samples, such as ethyl ether, through a spectral scan.<br />

You can use the 0.025 mm thickness cells for highly polar,<br />

pure liquids. The 0.1 - 0.2 mm thick cells are designed for<br />

samples that are weak absorbers of infrared energy.<br />

Easy to Fill and Clean<br />

The sample filling orifice is compatible with Luer-Lok<br />

hypodermic syringes. Two syringes are recommended<br />

when cleaning the cell. Never use viscous materials which<br />

are difficult to remove from a sealed liquid cell. Instead,<br />

use a semi-demountable cell.<br />

Variety of Window Materials Available<br />

Different window materials are available to accommodate<br />

your wavelength range requirements and to permit working<br />

with aqueous and non-aqueous samples.<br />

Sealed cells come with the windows and pathlength specified.<br />

Each cell includes a pair of Teflon plugs. Simply order the<br />

cell configuration you want using a single part number. All<br />

sealed cells use rectangular windows. The cells are calibrated<br />

and shipped in desiccated and sealed plastic containers.<br />

Rectangular Sealed Liquid Cells<br />

Window Material Pathlength Part No. Each (€)<br />

Sodium Chloride 0.025 mm L1270941 321<br />

0.05 mm L1270942 321<br />

0.1 mm L1270944 321<br />

0.2 mm L1270947 289<br />

0.5 mm L1270948 321<br />

1 mm L1270949 321<br />

Potassium Bromide 0.025 mm L1270951 330<br />

0.05 mm L1270952 330<br />

0.1 mm L1270954 366<br />

0.2 mm L1270957 366<br />

0.5 mm L1270958 366<br />

1 mm L1270959 312<br />

Calcium Fluoride 0.025 mm L1270961 570<br />

0.05 mm L1270962 570<br />

0.1 mm L1270964 570<br />

0.2 mm L1270967 570<br />

0.5 mm L1270968 856<br />

1 mm L1270969 602<br />

Zinc Selenide 0.1 mm L1270970 1181<br />

Luer-Lok Syringe<br />

for Sealed Liquid Cells<br />

Sealed Cell<br />

Part No.<br />

Each(€)<br />

04967845 11<br />

250


Semi-demountable Cells and Windows<br />

For High-Viscosity Liquids or Mull Samples<br />

By using rectangular windows instead of circular windows,<br />

the demountable cell becomes a semi-demountable cell. The<br />

semi-demountable cell can be used either as a demountable<br />

cell or as a sealed cell for high-viscosity liquids or mull<br />

samples. Combining two different requirements into one<br />

cell allows a myriad of different sampling applications.<br />

For Liquid Samples<br />

After assembling the cell, you<br />

can introduce the liquid sample<br />

through injection ports that<br />

are part of the top plate. The<br />

windows and spacers are not<br />

cemented together, allowing<br />

you to disassemble the cell<br />

easily. The semi-demountable<br />

cell is ideal for samples that<br />

are hard to clean or for<br />

unknown liquids which may<br />

contain moisture and attack<br />

hygroscopic window materials.<br />

For Mull Samples<br />

Liquid cells can also be used if Demountable Cell<br />

your sample is a Nujol mull<br />

or a capillary film, just use two undrilled windows and use<br />

the cell as a straight demountable cell. Select from a wide<br />

variety of window materials to meet your analytical needs.<br />

To order a semi-demountable cell, order the Universal<br />

Demountable Cell and your choice of windows and spacers.<br />

A thickness-compensating spacer is required for 2 mm<br />

thick windows. Alternatively, the complete kit can be<br />

ordered preassembled.<br />

Universal Demountable<br />

Cell Mount<br />

Includes top and back plates.<br />

Semi-demountable Cell Parts<br />

Part No.<br />

Components Part No. Each (€)<br />

1<br />

Back Plate<br />

23 Window Aligner 04821132 12<br />

31 Neoprene TM Gasket L1270512 15<br />

43 Undrilled Window (see product listing at right)<br />

53 Spacer (see product listing at right)<br />

63 Drilled Window (see product listing at right)<br />

73 Top Plate<br />

84 Teflon Plugs (pkg. 6) 04821008 6<br />

92 Quick Release Nut 04821131 14<br />

Sampling Accessories and Supplies<br />

Each (€)<br />

L1270986 299<br />

Liquid Sampling Cells and Supplies<br />

Rectangular Semi-demountable Cell Windows<br />

Rectangular Semi-demountable Cell Windows are available<br />

in a variety of window materials. All windows come in<br />

pairs and measure 41 x 23 mm (H x W).<br />

Window Material Thickness Part No. Each (€)<br />

Sodium Chloride 4 mm L1271191 157<br />

Potassium Bromide 4 mm L1271192 155<br />

Calcium Fluoride 4 mm L1271193 247<br />

Barium Fluoride 4 mm L1271194 741<br />

Cesium Iodide 4 mm L1271195 1655<br />

Zinc Selenide 2 mm L1270765 792<br />

Silver Bromide 2 mm L1270666 1987<br />

Thallium Bromide-Iodide 2 mm L1270664 759<br />

Rectangular Spacers for Rectangular<br />

Semi-demountable Cell Windows<br />

Spacer Material Thickness Qty. Part No. Each (€)<br />

Lead 0.025 mm 10 L1270301 74<br />

Teflon 0.05 mm 6 L1270402 74<br />

Teflon 0.1 mm 6 L1270404 61<br />

Teflon 0.2 mm 3 L1270408 74<br />

Teflon 0.5 mm 3 L1270409 74<br />

Teflon 1 mm 3 L1270410 61<br />

Assorted (2 of each) L1270421 97<br />

Rectangular Semi-demountable<br />

Cell Kits (Preassembled)<br />

Window Material Pathlength Part No. Each (€)<br />

Sodium Chloride 0.025 mm L1270741 278<br />

0.05 mm L1270742 292<br />

0.1 mm L1270744 273<br />

0.2 mm L1270747 273<br />

0.5 mm L1270748 273<br />

1 mm L1270749 273<br />

Potassium Bromide 0.025 mm L1270751 330<br />

0.05 mm L1270752 366<br />

0.1 mm L1270754 312<br />

0.2 mm L1270757 366<br />

0.5 mm L1270758 366<br />

1 mm L1270759 366<br />

Calcium Fluoride 0.025 mm L1270761 500<br />

0.05 mm L1270762 570<br />

0.1 mm L1270764 570<br />

0.2 mm L1270767 500<br />

0.5 mm L1270768 500<br />

1 mm L1270769 570<br />

1 2 3 4 5 6<br />

7<br />

8<br />

9<br />

Sampling Accessories and Supplies Infrared Spectroscopy<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

251


Infrared Spectroscopy Sampling Accessories and Supplies<br />

Sampling Accessories and Supplies<br />

Microscopy Sampling Accessories and Supplies<br />

Beam Condensers<br />

5X Beam Condenser<br />

For Easy Analysis of Microsamples<br />

FT-IR Beam Condenser Part No. 01860794<br />

A beam condenser is required for microsamples such<br />

as KBr microdisks, paint flakes, small spots on polymer<br />

films, and even single fibers when an optional fiber holder<br />

is used. The optical design of the 5X Beam Condenser<br />

provides optimum light-gathering power and ease of use<br />

when working with microsamples. The 5X Beam Condenser<br />

includes the transfer optics and Microsample Disk Holder.<br />

Benefits include:<br />

Easy measurement of microgram and submicrogram<br />

quantities of sample<br />

Highly efficient optical design results in high-quality<br />

FT-IR spectra<br />

Miniature Diamond Anvil Cell available for high-pressure<br />

analysis of small, optically thick polymeric samples<br />

Part No.<br />

Each (€)<br />

01860794 2751<br />

Diamond Anvil Cell<br />

Horizontally Mounted Stage, Holder<br />

for Miniature Diamond Anvil Cell<br />

Microfocus Accessory<br />

The Microfocus Accessory is a low-cost Beam Condenser<br />

for transmission measurement of<br />

small samples such as fibers and<br />

paint flakes.<br />

Part No.<br />

L1160550<br />

Each (€)<br />

616<br />

40-Micron Aperture for<br />

Microfocus Accessory<br />

(pkg. 5)<br />

250-Micron Aperture for<br />

Microfocus Accessory<br />

(pkg. 5)<br />

18-Micronfiber Holder for 5X Beam Condenser<br />

or Microfocus Accessory<br />

(pkg. 5)<br />

33-Micronfiber Holder for 5X Beam Condenser<br />

or Microfocus Accessory<br />

(pkg. 5)<br />

Part No.<br />

Part No.<br />

Part No.<br />

Each (€)<br />

L1160585 137<br />

Part No.<br />

Each (€)<br />

L1160583 197<br />

Each (€)<br />

L1160581 440<br />

Part No.<br />

Each (€)<br />

N9302618 6000<br />

Part No.<br />

Each (€)<br />

01862812 200<br />

Each (€)<br />

L1160582 159<br />

252


Microsampling Tools<br />

PerkinElmer offers a range of carefully selected tools and<br />

<strong>supplies</strong> which allow you to prepare and manipulate<br />

samples for infrared microspectroscopy.<br />

Microsampling Tool Kit<br />

Includes: Dissecting Forceps (N9302610), Roller Knife<br />

(N9302619), Micro Specimen Tweezers (N9302609),<br />

Tungsten Microneedle (N9302604), Straight Micro Probe<br />

(N9302605), Aluminum Probe Handle<br />

(N9302622), and Pin Vise (N9302603). Part No. Each (€)<br />

Dissecting Forceps<br />

Cadmium-plated, sharp<br />

points 4 in. long, serrated tip.<br />

Roller Knife<br />

Consists of razor knife at one end and a roller-wheel device<br />

for pressing samples at the other end. Use for cutting and<br />

sectioning specimens and for<br />

flattening samples such as fibers,<br />

hairs, and crystals.<br />

Part No.<br />

N9302619<br />

Each (€)<br />

77<br />

Tweezers<br />

Description Part No. Each (€)<br />

Very sharp points, excellent for N9302609 77<br />

miniature and micro specimens<br />

Non-magnetic, stainless steel points N9302607 63<br />

are 0.055" wide, rounded tips<br />

Narrow needle points, indented shanks N9302608 71<br />

Tungsten Microneedle<br />

Tungsten alloy, 0.0002 in. tip.<br />

Straight Micro Probe<br />

Stainless steel, very sharp.<br />

Angled Micro Probe<br />

Stainless steel, very sharp, 90° bend.<br />

Aluminum Probe Handle<br />

For screw-based probes. At least<br />

one handle must be ordered.<br />

Pin Vise<br />

Use for specimen preparation to separate fibres and films.<br />

Range 0 - 1 mm. (Holds tungsten wires that are sharpened<br />

to a fine point by placing them<br />

in a burner flame and then<br />

in sodium nitrate).<br />

Part No.<br />

N9302603<br />

Each (€)<br />

22<br />

Sampling Accessories and Supplies<br />

N1870151 293<br />

Part No.<br />

Microscopy Sampling Accessories and Supplies<br />

Each (€)<br />

N9302610 15<br />

Part No.<br />

Each (€)<br />

N9302604 56<br />

Part No.<br />

Each (€)<br />

N9302605 56<br />

Part No.<br />

Each (€)<br />

N9302606 56<br />

Part No.<br />

Each(€)<br />

N9302622 22<br />

Rotatable Cell Holder and<br />

Microscope Supplies<br />

Rotatable Cell Holder<br />

Requires, but does not include,<br />

Rotatable Cell Holder Plate.<br />

Rotatable Cell Holder Plate<br />

Sample Holder<br />

3 x 13 mm.<br />

Sample Holder with Gold Mirror<br />

Spare Germanium Crystal<br />

with Holder<br />

For ATR Objective.<br />

Spare Silicon Crystal with Holder<br />

For ATR Objective.<br />

Base Microscope Slides<br />

Box of 72, 1 x 3 in., 1 mm thick, optical<br />

quality glass, for visible observations.<br />

Infrared Windows<br />

Part No.<br />

Each (€)<br />

L1861790 43<br />

Part No.<br />

Each (€)<br />

L1861789 48<br />

Part No.<br />

Each (€)<br />

L1861634 32<br />

Part No.<br />

Each (€)<br />

L1860409 119<br />

Part No.<br />

Each (€)<br />

L1860268 1555<br />

Part No.<br />

Each (€)<br />

L1860269 2081<br />

Part No.<br />

Each (€)<br />

N9302600 23<br />

Infrared windows allow you to support microsamples<br />

for infrared analysis with the microscope. All windows are<br />

13 mm diameter and are available in the Infrared crystals<br />

designated below.<br />

Window Material Dimensions Part No. Each (€)<br />

Barium Fluoride 13 x 1 mm N9302611 196<br />

Barium Fluoride 13 x 2 mm N9302612 182<br />

Zinc Selenide 13 x 1 mm N9302613 223<br />

Sodium Chloride 13 x 2 mm N9302614 32<br />

Potassium Bromide 13 x 2 mm N9302615 43<br />

Sampling Accessories and Supplies Infrared Spectroscopy<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

253


Infrared Spectroscopy Sampling Accessories and Supplies<br />

Sampling Accessories and Supplies<br />

Microscopy Sampling Accessories and Supplies<br />

Sampling Accessories<br />

FT-IR Microscope Sampling Accessory Kit<br />

Includes two KBr windows (13 x 2 mm), Rotatable Sample<br />

Disk Holder, two 3 x 1 in. three-position sample holders with<br />

13 mm apertures (one position with a fixed gold-coated glass<br />

mirror), sample spacer for large samples, view-through<br />

variable apertures set, 100-micron pin hole aperture,<br />

low-magnification screen, and sample accessory<br />

carrying case. Supplied as standard<br />

with AutoIMAGE TM Systems.<br />

Part No. Each (€)<br />

Whole Field Aperture Kit*<br />

Rotatable Cell Holder<br />

Rotatable Cell Holder Plate<br />

Holder for Reflection<br />

Transmission Measurements*<br />

* Included in FT-IR Microscope Sampling Accessory Kit (L1860250).<br />

Hot Stage Accessory<br />

L1860250 1579<br />

Simplifies the isolation of the sample areas for Infrared<br />

examination by allowing the sample to be kept in view,<br />

even when an aperture is in place.<br />

Part No. Each (€)<br />

L1860249 574<br />

Part No.<br />

Part No.<br />

Each (€)<br />

L1861790 43<br />

Part No.<br />

Each (€)<br />

L1861789 48<br />

Each (€)<br />

N1873124 67<br />

Consists of a heating block, which accepts FT-IR windows<br />

and a temperature controller. The heating block contains<br />

an integral thermocouple; the temperature is digitally<br />

displayed in degrees Centigrade on the controller. The Hot<br />

Stage can heat samples up to 230 °C in 1° increments. A<br />

target temperature may be selected and maintained. The<br />

Hot Stage is held in the slide clip on the sample stage of a<br />

PerkinElmer FT-IR Microscope. The microscope requires<br />

no modifications to accept the Hot Stage Accessory.<br />

Power Requirement Part No. Each (€)<br />

100/120 V, 60 Hz N1870184 6600<br />

220/240 V, 50 Hz N1870188 6800<br />

AutoIMAGE<br />

Compression Cell<br />

This is a device for flattening soft materials and holding<br />

specimens flat and in optical contact with salt windows.<br />

The cell consists of an aluminum block machined to<br />

accept FT-IR windows, window retainers, and a special<br />

wrench to apply pressure across the IR windows. The<br />

specimen is held between two FT-IR windows. The<br />

Compression Cell fits into the sample slide holder on the<br />

stage of the FT-IR microscope. One- and two-millimeter<br />

thick windows of 13 mm outer diameter can be used with<br />

the cell; two KBr windows (2 mm thickness) are included.<br />

The cell can apply pressure without rotating (and therefore<br />

scratching) the windows. Fits both MultiScope TM<br />

and AutoIMAGE systems.<br />

Part No. Each (€)<br />

N1870185 760<br />

254


Diffuse Reflectance Accessories<br />

Ideal for Measurement of Opaque or Highly Scattering Samples<br />

Diffuse Reflectance Accessory provides a convenient and<br />

sensitive method for analyzing opaque or highly scattering<br />

solid samples such as pharmaceuticals, food products, soap<br />

powders, coal, clay, paper, painted surfaces, polymer foam,<br />

and catalysts.<br />

Fast, reproducible measurement; no alignment<br />

Flexibility for different sample holders to accommodate<br />

macro- and microsampling<br />

cups, silicon carbide<br />

abrasive pads, and<br />

diamond abrasive<br />

sampling sticks<br />

No sample preparation<br />

using unique abrasive<br />

pads and sticks<br />

Robust design with<br />

enclosed optics<br />

Macrosample Cup<br />

Description Qty. Part No. Each (€)<br />

For Spectrum One/100 1 L1201654 74<br />

For Pre-Spectrum One 1 L1271012 14<br />

Microsample Cup<br />

Description Qty. Part No. Each (€)<br />

For Spectrum One/100 1 L1201655 74<br />

For Pre-Spectrum One 1 L1271013 14<br />

Abrasive Pad<br />

Description Qty. Part No. Each (€)<br />

Metal-Coated Silicon Carbide 100 L1275106 299<br />

Uncoated Silicon Carbide 100 L1271021 110<br />

Abrasive Sampling Stick<br />

Description Qty. Part No. Each (€)<br />

Metal-Coated Diamond 100 L1275105 484<br />

Uncoated Diamond 100 L1275102 407<br />

Multi-Purpose Sample Holder<br />

Diffuse Adapter Kit<br />

For 2000 or GX to Spectrum One/100.<br />

Part No.<br />

Sampling Accessories and Supplies<br />

Diffuse Reflectance Accessory<br />

Each (€)<br />

L1201865 138<br />

Part No.<br />

Each (€)<br />

L1200394 185<br />

Horizontal Attenuated Total<br />

Reflectance (HATR) Accessories<br />

Reflectance Accessories<br />

A Fast, Reliable Means for Analyzing a Wide Variety of Samples<br />

Based on an attenuated total reflectance principle, the<br />

PerkinElmer Horizontal ATR (HATR) Accessory offers a<br />

fast, reliable means for analyzing a wide range of solid,<br />

liquid, and paste samples not easily examined by<br />

conventional transmission techniques.<br />

HATR Top Plates for Spectrum One/100<br />

Plate Material Angle Plate Type Part No. Each (€)<br />

ZnSe 45° Flat L1200313 730<br />

45° Trough L1200314 730<br />

60° Flat L1200315 730<br />

60° Trough L1200316 730<br />

Coated ZnSe* 45° Flat L1200323 1232<br />

45° Trough L1200324 1232<br />

60° Flat L1200325 1232<br />

Ge 30° Flat L1200337 891<br />

30° Trough L1200338 891<br />

45° Flat L1200333 891<br />

45° Trough L1200334 891<br />

60° Flat L1200335 891<br />

60° Trough L1200336 891<br />

AMTIR 45° Flat L1200343 1148<br />

45° Trough L1200344 1148<br />

60° Flat L1200345 1148<br />

60° Trough L1200346 1148<br />

* Includes special protective coating on the crystal for extended lifetime.<br />

HATR Top Plates for Pre-Spectrum One<br />

Plate Material Plate Type Part No. Each (€)<br />

ZnSe Flat L1360267 628<br />

Trough L1360266 628<br />

Ge Flat L1360269 837<br />

Trough L1360268 837<br />

AMTIR Flat L1360271 837<br />

Trough L1360270 837<br />

KRS-5 Flat L1360273 837<br />

Trough L1360272 837<br />

HATR Accessory<br />

Sampling Accessories and Supplies Infrared Spectroscopy<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

255


Infrared Spectroscopy Sampling Accessories and Supplies<br />

Sampling Accessories and Supplies<br />

Reflectance Accessories<br />

Pressure Arm Kit<br />

for the Spectrum One<br />

HATR Adapter Kit<br />

Description Part No. Each (€)<br />

2000 to 1000 or GX to either RX or BX L1360274 150<br />

2000 or GX to Spectrum One/100 L1200393 185<br />

HATR Variable Pressure<br />

Clamp Assembly<br />

FT-NIR Reflectance Accessories<br />

FT-NIRA Solids Rotating Sample Holder<br />

Provides improved repeatability for reflectance measurements<br />

of coarse, granular materials. Requires, but does not include,<br />

Spectrum One NTS/100N FT-NIRA (L1240050).<br />

Set of Five Spare Glass Sample Dishes for FT-NIRA<br />

Solids Rotating Sample Holder<br />

High-Performance Sample Dish<br />

for FT-NIRA Solids Rotating Sample Holder<br />

Comprises high-quality Suprasil base.<br />

Sample Cup for the Spectrum<br />

IdentiCheck Reflectance Accessory<br />

Description Qty. Part No. Each (€)<br />

Upper Position 3 L1181318 1507<br />

Lower Position 4 L1181319 329<br />

FT-NIRA Transflectance Liquids<br />

Sampling Accessory Starter Kit<br />

Includes five Liquids Reflectors<br />

and Petri dish bases, FT-NIRA Liquids<br />

Sampling procedure, and user guide.<br />

FT-NIRA Transflectance Liquids<br />

Sampling Accessory Kit<br />

Includes 100 FT-NIRA Liquids<br />

Reflectors and Petri dish bases.<br />

Part No.<br />

Each (€)<br />

L1200321 592<br />

Part No.<br />

Each (€)<br />

L1360275 281<br />

Part No.<br />

Each (€)<br />

L1240053 1016<br />

Part No.<br />

Each (€)<br />

L1181257 110<br />

Part No.<br />

Each (€)<br />

L1185305 281<br />

Part No.<br />

Each (€)<br />

L1185153 99<br />

Part No.<br />

Each (€)<br />

L1180501 865<br />

FT-NIRA Liquids Petri Dish Base<br />

(pkg. 100)<br />

FT-NIRA Liquids Reflector<br />

(pkg. 100)<br />

Disposable Glass Vials for FT-NIRA<br />

4 mL glass vials with cap, (pkg. 100).<br />

Specular Reflectance Accessories<br />

Variable-Angle Specular Reflectance Accessory<br />

Flat Reference Mirror<br />

Aperture Mask<br />

For Measurement of Samples<br />

with Glossy Coatings and<br />

Reflective Surfaces<br />

PerkinElmer offers both Fixedangle<br />

and Variable-angle Specular<br />

Reflectance Accessories. Optimized<br />

to match the throughputs of all<br />

PerkinElmer FT-IR spectrometers,<br />

these accessories provide<br />

unmatched ease of use and<br />

optical efficiency.<br />

Replacement Reference<br />

Mirrors and Aperture<br />

Masks are available<br />

separately. Aperture<br />

Masks are available<br />

in 3 sizes for<br />

studying a variety<br />

of small sample areas.<br />

Aperture Part No. Each (€)<br />

2 mm 01861854 35<br />

5 mm 01861861 35<br />

10 mm 01861862 35<br />

Universal Attenuated Total<br />

Reflectance (ATR) Accessories<br />

Spectrum One Universal ATR Optional/<br />

Replacement Top-Plate<br />

Part No.<br />

Each (€)<br />

L1180502 386<br />

Part No.<br />

Each (€)<br />

L1180503 602<br />

Part No.<br />

Each (€)<br />

L9001029 78<br />

Part No.<br />

Each (€)<br />

00071006 119<br />

Description Part No. Each (€)<br />

1 Reflection Top-Plate L1200364 4306<br />

3 Reflection Top-Plate L1200365 4306<br />

9 Reflection Top-Plate L1200366 4306<br />

Pressure Arm Kit L1200321 592<br />

256


Liquid and Mull FT-IR Sampling Kit Part No. L1365311<br />

FT-IR Sampling Kits<br />

Two FT-IR Sampling Kits are available to help the newcomer<br />

to FT-IR spectroscopy choose the more frequently required<br />

items, and to simplify ordering and storage. KBr has been<br />

chosen for the transmitting material. The two kits are<br />

packaged in attractive storage and carrying cases.<br />

Liquid and Mull FT-IR Sampling Kit<br />

This kit will satisfy the needs of most new users of FT-IR<br />

spectroscopy and has been designed to provide all the<br />

necessary equipment for handling liquids and mulls. A<br />

magnetic film holder is also included.<br />

Includes:<br />

Polystyrene Film (0.038 mm)<br />

Nujol DD 057 (100 mL)<br />

10 cm Micro Spatula<br />

2 mL Luer Syringe<br />

Agate Pestle and Mortar<br />

Magnetic Film Holder – Circular<br />

Universal Demountable Cell Mount<br />

Assorted Spacers<br />

KBr Demountable Cell Windows (two pairs)<br />

KBr Semi-demountable Cell Windows (two pairs)<br />

Part No.<br />

Sampling Accessories and Supplies<br />

Each (€)<br />

L1365311 2117<br />

General Purpose FT-IR Sampling Kit<br />

Sampling Kits and Supplies<br />

General Purpose FT-IR Sampling Kit Part No. L1365312<br />

This kit includes all of the necessary equipment for handling<br />

liquids, mulls, and KBr pellets and also includes a magnetic<br />

film holder and a Microfocus Accessory. It should be noted<br />

that a laboratory press for making KBr pellets should be<br />

ordered separately.<br />

Includes:<br />

Polystyrene Film (0.038 mm)<br />

Universal KBr Disk Holder<br />

Nujol DD 057 (100 mL)<br />

10 cm Micro Spatula<br />

2 mL Luer Syringe<br />

Agate Pestle and Mortar<br />

Magnetic Film Holder – Circular<br />

KBr Powder (100 g)<br />

13 mm KBr Die<br />

Micro-disk Holder Accessory<br />

Beam Condenser Accessory<br />

100 μm Diameter Sample Holder Accessory<br />

500 μm Diameter Sample Holder Accessory<br />

Universal Demountable Cell Mount<br />

Assorted Spacers<br />

KBr Demountable Cell Windows (two pairs)<br />

KBr Semi-demountable Cell Windows (two pairs)<br />

FT-IR Sampling Kit Supplies<br />

Part No.<br />

Each (€)<br />

L1365312 3242<br />

Description Size Part No. Each (€)<br />

Nujol 100 mL 04960691 58<br />

Fluorolube TM 1 oz bottle 01862301 41<br />

KBr Powder 100 g 04977043 131<br />

KBr Random Cuttings 100 g bottle N9300086 103<br />

Micro Spatula 10 cm 04967843 11<br />

Luer Syringe 2 mL 04967845 11<br />

Agate Pestle and Mortar 04967854 91<br />

Sampling Accessories and Supplies Infrared Spectroscopy<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

257


Infrared Spectroscopy Sampling Accessories and Supplies<br />

Sampling Accessories and Supplies<br />

Solid Sampling Accessories and Supplies<br />

There are several options to consider when analyzing<br />

solid samples. Depending on the chemical composition<br />

and spectral information needed you can select any of<br />

the following techniques:<br />

Prepare a potassium bromide pellet<br />

Formulate a sample mull<br />

Measure directly with a diffuse reflectance accessory<br />

Hydraulic Press and Evacuable<br />

Potassium Bromide Die<br />

The KBr pellet technique is probably the one most often<br />

used to prepare solid samples for infrared analysis. First the<br />

sample is ground to a fine particle size and then mixed<br />

uniformly with dry KBr powder. Finally, this sample is<br />

placed in an evacuable KBr die and a 13 mm clear disk is<br />

pressed in a hydraulic press to form a KBr pellet. Pellets can<br />

also be prepared using less expensive and quicker methods.<br />

Manual Hydraulic Press<br />

Manual Hydraulic Press<br />

This compact and easy-to-operate press is used with the<br />

KBr die to prepare KBr pellets.<br />

The pressure is produced by<br />

operating a pump lever.<br />

Part No.<br />

51004599<br />

Each (€)<br />

3430<br />

Water-Cooled Heated Platens<br />

with Automatic Temperature Control (300 °C)<br />

Model Power Req. Part No. Each (€)<br />

Specac 110 V, 60 Hz 04978444 4421<br />

220 V, 50 Hz 04978443 4421<br />

PerkinElmer 110 V, 60 Hz L1270504 2261<br />

220 V, 50 Hz L1270503 2261<br />

Evacuable Potassium Bromide Die<br />

The Evacuable Potassium Bromide Die will<br />

prepare 13 mm diameter pellets of the highest<br />

quality and clarity. The pellet is formed inside<br />

an evacuated chamber and pressed between a<br />

highly polished anvil and plunger. This die is<br />

precisely constructed to produce pellets<br />

of uniform quality and will continue<br />

to provide many years of service in<br />

your laboratory.<br />

Part No. Each (€)<br />

Evacuable Potassium Bromide Die Accessories<br />

The following parts are included with the Evacuable<br />

Potassium Bromide Die, but can also be ordered separately:<br />

Description Part No. Each (€)<br />

Plunger 51001152 170<br />

Set of Upper and Lower Anvils 04820519 195<br />

Set of O-Rings 04800514 150<br />

Perspex TM Extractor Ring 04977042 50<br />

Potassium Bromide Pellet Holder<br />

A KBr Pellet Holder is required,<br />

but must be ordered separately.<br />

Adjustable Adapter<br />

The Adjustable Adapter is required in order to mount<br />

the Potassium Bromide Pellet Holder<br />

in your FT-IR spectrometer.<br />

Part No. Each (€)<br />

L1060351 46<br />

Constant Thickness Film Maker<br />

A constant thickness film maker is available as an option<br />

for this press. When used in conjunction with heated<br />

platens and a press, it enables quick preparation of polymer<br />

film samples for qualitative and<br />

quantitative analysis.<br />

Part No. Each (€)<br />

Support Rings For KBr Pellets<br />

51001144 478<br />

Part No.<br />

Each (€)<br />

04810949 142<br />

04977032 2572<br />

Circular paper rings to reinforce your KBr disks are available.<br />

If the amount of sample is limited there are also paper<br />

microframes which reduce the size of the pellet to 11 x 2 mm.<br />

Description Qty. Part No. Each (€)<br />

Paper Rings 100 51001148 170<br />

Microframes 100 51001149 114<br />

258


KBr Pellet Mini-press<br />

The Mini-press is designed for those situations where you<br />

occasionally need to make KBr pellets. This is the simplest<br />

solid sample device and is ideal for student use, where very<br />

low cost is an important factor. Two highly polished bolts<br />

turn against each other in a steel cylinder. The pellet is<br />

formed right inside the cylinder which becomes the sample<br />

holder. Once formed, the pellet cannot be removed from the<br />

cylinder without being destroyed. The Mini-press requires<br />

but does not include the holder.<br />

Evacuable KBr Mini-press<br />

Holder for Evacuable<br />

KBr Mini-press<br />

KBr Pellet Quick Press<br />

The Quick Press provides a fast and economical way to<br />

prepare good quality KBr pellets. A hydraulic press is not<br />

needed and pellets with diameters of 1, 3, or 7 mm can be<br />

prepared, depending on the die sets used. The Quick Press<br />

is simple and easy to use. Simply load the sample and<br />

potassium bromide mixture into the selected die. Place the die<br />

in position in the Quick Press. Then apply a steady pressure<br />

to the handle, equivalent to that of a firm handshake.<br />

Quick Press<br />

Quick Press<br />

Part No.<br />

The Quick Press consists of a handpress, a 7 mm die set,<br />

and a metal collar.<br />

Part No. Each (€)<br />

Sampling Accessories and Supplies<br />

Each (€)<br />

51002592 211<br />

Part No.<br />

Each (€)<br />

51002593 84<br />

01860436 1145<br />

Solid Sampling Accessories and Supplies<br />

Die Sets for Micropellets<br />

Micropellets can be prepared in the Quick Press by<br />

purchasing the optional 3 or 1 mm die. The KBr pellet is<br />

formed in a metal collar that fits into an adjustable Pellet<br />

Holder. The 1 mm micro-KBr pellets can be used in the<br />

PerkinElmer 5X Beam Condenser Accessory.<br />

Die Size Part No. Each (€)<br />

1 mm 01862295 355<br />

3 mm 01862292 343<br />

7 mm 01862289 305<br />

Adjustable Pellet Holder Adapter<br />

Required, but not included,<br />

with Quick Press.<br />

Polarizers<br />

Polarized radiation is used to study orientation effects<br />

in single crystals, polymers, and other large molecules.<br />

Polarization measurements are also used to determine<br />

optical constants and to assist in the assignment of<br />

observed absorption bands to normal modes of vibration.<br />

The Spectrum GX, Spectrum 2000, and System 2000 FT-IR<br />

spectrometers can have software controlled polarizers<br />

installed inside the instrument, but other PerkinElmer<br />

infrared instruments will require a polarizer, mounted<br />

in the sample compartment.<br />

Polarizer Kits<br />

Description Part No. Each (€)<br />

Mid-IR, Thallium Bromide-Iodide L1271025 3218<br />

Far-IR, Polyethylene L1271026 2309<br />

Near-IR, Calcium Fluoride L1271027 2966<br />

Visible Polarizer Kit<br />

Useful for the study of crystalline materials, most of which<br />

exhibit bi-refringence (i.e. double refraction). Areas of<br />

disparate chemical composition can be differentiated<br />

by observation under crossed polarizers (i.e. a fiber in<br />

a polymer, gel imperfections in polymer film, different<br />

layers in a laminated structure). Fits both MultiScope<br />

and AutoIMAGE systems.<br />

Part No. Each (€)<br />

Infrared Polarizer Kit<br />

Part No.<br />

Each (€)<br />

L1060351 46<br />

L1860221 1639<br />

Used to study orientation effects of single crystals,<br />

polymers and other large molecules. Fits both MultiScope<br />

and AutoIMAGE systems.<br />

Part No. Each (€)<br />

L1860408 3648<br />

Sampling Accessories and Supplies Infrared Spectroscopy<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

259


Infrared Spectroscopy Sampling Accessories and Supplies<br />

Sampling Accessories and Supplies<br />

Solid Sampling Accessories and Supplies<br />

FT-NIR Remote Immersion Probe Part No. L1181314<br />

Remote Sampling System Accessories<br />

Remote Solids Probe Kit<br />

Featuring probe and connecting fibers.<br />

Only for use with the Spectrum<br />

One NTS/100N.<br />

Replacement Remote Solids Fiber Cable<br />

For use with the High-Performance<br />

Remote Solids Sampling System.<br />

Spare Solids Probe Reflectance Cap<br />

For use with the High-Performance<br />

Remote Solids Sampling System.<br />

FT-NIR Remote Immersion Probe<br />

Pathlength Part No. Each (€)<br />

10 mm L1181314 9900<br />

1 mm L1181316 9900<br />

Sample Holders and Film Mounts<br />

A variety of sample holders and film mounts are available to<br />

accommodate polymer films and other thin samples<br />

Magnetic Film Holder<br />

Use the Magnetic Film Holder to hold polymer films<br />

and a wide variety of other thin samples by placing them<br />

between the ring-shaped magnet and<br />

the backplate.<br />

Part No. Each (€)<br />

Spring-Loaded Sample Holder<br />

This sample holder consists of a clamping plate held by<br />

light spring tension. Use it to hold single windows, films,<br />

filters, or films mounted on cards.<br />

Part No. Each (€)<br />

Adhesive Film Mounts<br />

Part No.<br />

Each (€)<br />

L1240062 15000<br />

Part No.<br />

Each (€)<br />

L9001162 4876<br />

Part No.<br />

Each (€)<br />

L1245221 97<br />

04974438 82<br />

01860470 66<br />

These convenient, easy-to-use, and economical cardboard<br />

mounts permanently hold polymer films or other thin<br />

samples. Just place the film over the aperture and fold<br />

the adhesive sides together to form a permanent mount.<br />

The mounts fit directly into the<br />

sample slide of the spectrometer. Part No. Each (€)<br />

(pkg. 100)<br />

01860449 148<br />

260


Software<br />

Spectrum Infrared Software<br />

Application Software Packages<br />

Spectrum Search Plus Software<br />

Provides a library search and match capability with five<br />

different algorithms, and an expert system for spectral<br />

interpretation, resulting in a chemical functional group<br />

listing of the possible structural units (PSUs) displayed on<br />

the screen. In addition, Spectrum Search can perform<br />

interactive interpretation. The program includes provision<br />

for the entry of chemical and physical data about the sample,<br />

which can be used to eliminate obvious mismatches. The<br />

output includes the 28 closest matches from a single library<br />

or any group of libraries. The Fluka library (1725 spectra), an<br />

ATR Polymer library (100 spectra), a Raman Polymer library<br />

(100 spectra), and a Small Drugs library are included as<br />

standard. Spectrum Search Plus can be used in conjunction<br />

with the complete Sadtler collection of libraries. The software<br />

provides full builder graphics and multiple spectra split<br />

display. Included is a license certificate<br />

to access Spectrum Search Plus, which<br />

Part No. Each (€)<br />

resides on the Spectrum Software CD. L1108755 1876<br />

IR Expert Software<br />

Allows indication of spectrum quality and common<br />

measurement problems, causes and cures. Also included<br />

is automatic data optimization according to user-defined<br />

parameters. Included is a license certificate to access IR<br />

Expert, which resides on the Spectrum Software CD. Only<br />

available for Spectrum One systems.<br />

Part No. Each (€)<br />

Spectrum QUANT+<br />

This package is a multicomponent quantitative analysis<br />

package based on principal component regression (PCR).<br />

A complete set of diagnostics is available in graphical<br />

presentations to ensure proper calibration in easy-tounderstand<br />

formats. The statistical approach used by<br />

Spectrum QUANT+ enables it to ignore errors caused<br />

by uncontrolled variations from sample to sample, and<br />

minimize errors caused by sampling methods. In addition<br />

to measuring concentrations, Spectrum QUANT+ can relate<br />

spectral data to physical properties of the sample being<br />

analyzed. Up to 15 properties may be determined and up<br />

to 150 standards may be used in the calibration set.<br />

Included is a license certificate to<br />

Part No. Each (€)<br />

access Spectrum QUANT+, which<br />

resides on the Spectrum Software CD. L1108757 3095<br />

QUANT+ Upgrade<br />

L1108759 610<br />

Single-user upgrade for Spectrum QUANT+. Includes<br />

IR Spectroscopy CD, manual, and license certificate for<br />

Spectrum QUANT+.<br />

Part No. Each (€)<br />

L1108822 1117<br />

Spectrum QUANTC Software<br />

This package is designed for the quantitative analysis of<br />

mixtures using a least-squares curve-fitting algorithm to<br />

determine the concentration of up to 15 components from<br />

a single spectrum. Methods can be password protected<br />

and include a history file, which details the changes made<br />

during development. The software also includes method<br />

validation, trend analysis, component correlation spectra,<br />

and context-sensitive help. Included is a license certificate<br />

to access Spectrum QUANTC, which resides on the<br />

Spectrum Software CD.<br />

Part No. Each (€)<br />

QUANTC Upgrade<br />

Spectrum Procedures<br />

This is a FT-IR macro-programming package, which<br />

requires no programming or syntax checking. All the major<br />

elements of FT-IR analytical procedures, such as data<br />

collection, reports, labels, and push buttons, are available<br />

as modules that are combined like building blocks to create<br />

the procedure. Search, Spectrum QUANT+ and Spectrum<br />

QUANTC analysis can be used in the procedure. Once<br />

developed, procedures can be compiled as executable files<br />

and distributed as stand-alone applications or called from<br />

the Spectrum Software. Included is a license certificate to<br />

access Spectrum Procedures, which resides on the<br />

Spectrum Software CD. Requires,<br />

Part No. Each (€)<br />

but does not include, Microsoft<br />

Visual Basic v4.0 (16 bit), (L1108772). L1108760 1876<br />

Spectrum Procedures Upgrade<br />

Single-user upgrade for Spectrum Procedures. Includes<br />

FT-IR Spectroscopy CD, manual, and license certificate for<br />

Spectrum Procedures.<br />

Part No. Each (€)<br />

Visual Basic Kit v4.0<br />

L1108758 1876<br />

Single-user upgrade for Spectrum QUANTC. Includes<br />

IR Spectroscopy CD, manual, and license certificate for<br />

Spectrum QUANTC.<br />

Part No. Each (€)<br />

L1108824 657<br />

L1108823 657<br />

Required for Spectrum Procedures. Includes license and<br />

software for Microsoft Visual Basic v6.0 and downgrade<br />

CD to allow Microsoft Visual Basic<br />

v4.0 (16-bit) to be installed.<br />

Part No. Each (€)<br />

L1108772 1762<br />

Software Infrared Spectroscopy<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

261


Software<br />

Spectrum Infrared Software<br />

Infrared Spectroscopy Software<br />

Spectrum Procedures and Visual Basic Kit<br />

Includes Spectrum Procedures (L1108760)<br />

and Visual Basic (L1108772).<br />

PerkinElmer Educational Software Package<br />

Provide schools and colleges with software to advance<br />

students, understanding of FT-IR. IR-Tutor software guides<br />

students through the background and theory of FT-IR<br />

spectroscopy as well as how to interpret the spectra they<br />

collect. Spectrum software allows students to perform<br />

advanced processing on spectra, create professional<br />

reports, and use automatic spectral interpretation and<br />

comparison algorithms. Only available with order<br />

of a Spectrum BX or RX instrument.<br />

Includes:<br />

IR-Tutor software disks<br />

Spectrum Software CD and manual<br />

10-user license for IR-Tutor<br />

10-user license for Spectrum Software<br />

AutoIMAGE Upgrades<br />

AutoIMAGE Upgrade Kit<br />

Part No.<br />

Part No.<br />

Single-user license for AutoIMAGE v4.0 or earlier to<br />

AutoIMAGE v5.0 upgrade. Includes AutoIMAGE v5.0<br />

software and AutoIMAGE manuals. Requires, but does<br />

not include, AutoIMAGE Frame Grabber Card Upgrade<br />

Kit (L1860305).<br />

Specifications:<br />

AutoIMAGE v5.0 operates under the Windows 2000<br />

(service pack 2-4) and Windows XP Pro SP2 operating<br />

systems only<br />

Spectrum BX, 1000, and RX instruments cannot be upgraded<br />

to the latest AutoIMAGE v5.0 software<br />

Spectrum v5.0 is required to run AutoIMAGE v5.0<br />

AutoIMAGE v5.0 does not meet the technical requirements<br />

of 21 CFR Part 11 and therefore must not be installed onto<br />

systems with Spectrum ES v5.0 loaded<br />

AutoIMAGE Frame Grabber Card Upgrade Kit<br />

Each (€)<br />

L1108818 2338<br />

Each (€)<br />

L1108548 1314<br />

Part No.<br />

Each (€)<br />

LX108640 657<br />

This kit upgrades the AutoIMAGE frame grabber to allow<br />

the AutoIMAGE to be controlled by the latest AutoIMAGE<br />

v5.0 software running under Windows 2000. Includes the<br />

Mutech frame grabber card and a<br />

cable adapter to allow the AutoIMAGE<br />

to be connected to the PC.<br />

Part No.<br />

L1860305<br />

Each (€)<br />

2010<br />

PerkinElmer Stage Control Box<br />

This kit is required to upgrade from a Marzhauser stage<br />

controller to a PerkinElmer stage controller to achieve<br />

compatibility with AutoIMAGE v5.0 software. Includes<br />

stage control box, control cable,<br />

and installation instructions.<br />

Part No. Each (€)<br />

Spectrum One/100 AssureID<br />

Upgrades and Validation Suite<br />

Spectrum AssureID is a software suite providing a<br />

dedicated software solution for regulated industries.<br />

Using the latest database technology, data storage is<br />

secure, archival simple, and data retrieval quick.<br />

1. Spectrum AssureID addresses the need of manufacturing<br />

industries to improve product quality, realize efficiencies<br />

and meet the demands of regulatory bodies. It addresses<br />

the need to:<br />

Verify the identity and quality of raw materials, packaging<br />

materials, in-process materials, and finished products<br />

Monitor process variation<br />

Determine accurate concentration of active ingredients,<br />

excipients, additives, and moisture<br />

2. Spectrum AssureID addresses the needs of the QA/QC<br />

market by directly addressing the biggest issues:<br />

Faster than conventional technology allows more testing<br />

leading to better quality<br />

Deployed at the point of manufacture to maximize<br />

turnaround time and reduce cost of poor quality<br />

Simple enough to be used by process operatives<br />

Easy to develop, validate, and implement robust methods<br />

Complete set of compliance tools including intrinsic<br />

21 CFR Part 11 compliance<br />

AssureID operates with Spectrum One/100 MIR and<br />

Spectrum One/100 FT-NIR spectrometers and a whole<br />

host of plug and play accessories including Tablet<br />

Autosampler, FT-NIRA, UATR, HATR, etc.<br />

License to Upgrade Spectrum, Spectrum CFR<br />

or Spectrum ES to Spectrum AssureID v4.0<br />

License to Upgrade Spectrum AssureID v3.0<br />

or earlier to Spectrum AssureID v4.0<br />

L1860279 3260<br />

Part No.<br />

Part No.<br />

Each (€)<br />

LX100689 9400<br />

Each (€)<br />

LX100690 3128<br />

262


Software<br />

Spectrum Infrared Software<br />

Spectrum One Software Upgrades<br />

Spectrum One v6.0 Software Upgrade<br />

License to upgrade Spectrum v3.02 or earlier to Spectrum<br />

One v6.0. Includes Spectrum One v6.0 software, instrument<br />

control, data processing tools, spectral calculator, quantitative<br />

predictions, Spectrum Search, and Report Builder.<br />

5-user and 10-user licenses are available to enable customers<br />

who have already purchased a single-user license to install<br />

the software on additional systems. Instrument manuals are<br />

also included. Upgrade includes Spectrum, IR Expert, and<br />

Spectrum Search only. If upgrades to other software packages<br />

are required these must be ordered separately. Purchase of<br />

single-user license upgrade (LX108848) is a pre-requisite for<br />

purchase of 5-user and 10-user licenses.<br />

License Qty. Part No. Each (€)<br />

Single-user LX108848 788<br />

5-user LX100846 1970<br />

10-user LX100849 3153<br />

Spectrum One NTS v6.0 Software Upgrade<br />

License to upgrade Spectrum v3.02 or earlier to Spectrum<br />

One NTS v6.0. Includes Spectrum One NTS v6.0 software,<br />

instrument control, data processing tools, spectral calculator,<br />

and quantitative predictions, Quant+, QuantC, SIMCA, and<br />

Report Builder. 5-user and 10-user licenses are available to<br />

enable customers who have already purchased a single-user<br />

license to install the software on additional systems.<br />

Spectrum One NTS manuals are also included. Purchase<br />

of single-user license upgrade (LX108848) is a pre-requisite<br />

for purchase of 5-user and 10-user licenses.<br />

License Qty. Part No. Each (€)<br />

Single-user LX108848 788<br />

5-user LX100846 1970<br />

10-user LX100849 3153<br />

Spectrum GX v5.0 Upgrade<br />

Single-user license for Spectrum v3.02 or earlier to Spectrum<br />

GX v5.0 upgrade. Includes Spectrum GX v5.0 software,<br />

instrument control, data processing tools, spectral calculator,<br />

quantitative predictions, Spectrum Search, and Report<br />

Builder. Spectrum GX manuals are also included. Upgrade<br />

includes Spectrum and Spectrum Search only. If upgrades<br />

to other software packages are required these must be<br />

ordered separately.<br />

Part No. Each (€)<br />

L1100980 788<br />

Spectrum BX v5.0 Upgrade<br />

Single-user license for Spectrum v3.02 or earlier to Spectrum<br />

BX v5.0 upgrade. Includes Spectrum BX v5.0 software,<br />

instrument control, data processing tools, spectral calculator,<br />

quantitative predictions, Spectrum Search, and Report<br />

Builder. Spectrum BX manuals are also included. Upgrade<br />

includes Spectrum and Spectrum Search only. If upgrades<br />

to other software packages are required, these must be<br />

ordered separately.<br />

Part No. Each (€)<br />

Spectrum RX PC Software Upgrade<br />

L1100981 788<br />

Software kit to allow existing stand-alone Spectrum RX users<br />

to control the instrument with a PC. Includes Spectrum v5.0<br />

software, instrument control, data processing tools, spectral<br />

calculator, quantitative predictions, Spectrum Search, and<br />

Report Builder. IR Spectroscopy Software manual also<br />

included. The license number will refer to a Spectrum BX.<br />

This is also a valid license number for a Spectrum RX. When<br />

installed the instrument will be referred to in the software as<br />

a Spectrum BX. Requires, but does not include, RS232<br />

Communications Cable (09410022).<br />

Part No. Each (€)<br />

LX108689 2299<br />

Software Infrared Spectroscopy<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

263


Software Upgrade Kits<br />

Spectrum Infrared Software<br />

Infrared Spectroscopy Software Upgrade Kits<br />

Spectrum One Enhanced<br />

Security Software Upgrades<br />

Spectrum One ES v6.0 provides the power of Spectrum<br />

One v6.0 with the added benefit of 21 CFR Part 11 technical<br />

compliance. Spectrum One ES v6.0 achieves the highest<br />

standard for technical compliance in data security and<br />

integrity by the use of a proprietary security component and<br />

the implementation of audit trails, data security, and integrity<br />

features by 21 CFR Part 11 trained software engineers.<br />

Key compliance features:<br />

Full 21 CFR Part 11 technical compliance<br />

Password protected access control<br />

Multilevel user permissions<br />

Comprehensive audit-trailing<br />

Legacy data tool<br />

Available for Spectrum One/100, Spectrum One NTS/100N,<br />

and Spectrum GX<br />

Spectrum One ES v6.0 Upgrade<br />

License to upgrade prior Spectrum software versions to<br />

Spectrum One ES v6.0. Includes Spectrum One ES v6.0<br />

software, instrument control, data processing tools, spectral<br />

calculator, quantitative predictions, legacy data converter,<br />

reporting software plus an administration utility to set<br />

access control permissions to the software. 5-user and<br />

10-user licenses are available to enable customers who<br />

have already purchased a single-user license to install the<br />

software on additional systems. Spectrum One manuals<br />

are also included. Purchase of single-user license upgrade<br />

(LX108849 or LX108850) is a pre-requisite for purchase<br />

of 5-user and 10-user licenses.<br />

Prior Spectrum Software Version License Qty. Part No. Each (€)<br />

Spectrum CFR 4.0 Single-user LX108849 1314<br />

5-user LX100847 3284<br />

10-user LX100850 5300<br />

Spectrum v3.02 or earlier Single-user LX108850 3941<br />

5-user LX100847 3284<br />

10-user LX100850 5300<br />

Spectrum One NTS ES v6.0 Upgrade<br />

License to upgrade prior Spectrum software versions to<br />

Spectrum One NTS ES v6.0. Includes Spectrum One NTS<br />

ES v6.0 software, instrument control, data processing tools,<br />

spectral calculator, quantitative predictions, legacy data<br />

converter, reporting software plus an administration utility<br />

to set access control permissions to the software. 5-user<br />

and 10-user licenses are available to enable customers<br />

who have already purchased a single-user license to install<br />

the software on additional systems. Spectrum One NTS<br />

manuals are also included. Purchase of single-user license<br />

upgrade (LX108849 or LX108850) is a pre-requisite for<br />

purchase of 5 and 10-user licenses.<br />

Prior Spectrum Software Version License Qty. Part No. Each (€)<br />

Spectrum CFR 4.0 Single-user LX108849 1314<br />

5-user LX100847 3284<br />

10-user LX100850 5300<br />

Spectrum v3.02 or earlier Single-user LX108850 3941<br />

5-user LX100847 3284<br />

10-user LX100850 5300<br />

Spectrum GX ES v5.0 Upgrade<br />

Single-user license for Spectrum v3.02 or earlier to<br />

Spectrum GX ES v5.0 upgrade. Includes Spectrum GX ES<br />

v5.0 software, instrument control, data processing, spectral<br />

calculator, quantitative predictions, legacy data converter,<br />

reporting software, plus an administration utility to set access<br />

control permissions to the software.<br />

Spectrum GX manuals and an<br />

Part No. Each (€)<br />

administrators guide are also included. L1100974 3941<br />

264


Upgrade Kits<br />

Detector, Microscope, and Spectrum One/100 Upgrades<br />

Detector Upgrades<br />

Spectrum One/100 Upgrades<br />

MCT Mid-IR Detector Upgrade Kit<br />

Spectrum One/100 Systems can be upgraded to include<br />

an MCT Detector using one of these kits. Includes MCT<br />

Detector, MCT pre-amp, additional optics, and hardware.<br />

For instruments with serial number 53300 or lower, an<br />

MCT Casting Conversion Kit (L1200220) is also required<br />

and must be ordered separately.<br />

Description Part No. Each (€)<br />

NB 1 mm L1200236 7500<br />

MB 1 mm L1200237 7500<br />

WB 1 mm L1200238 7500<br />

MCT Casting Conversion Kit<br />

This conversion kit is required when<br />

upgrading Spectrum One Systems<br />

installed before September, 1999<br />

with an MCT Detector.<br />

Microscope Upgrades<br />

Microscope Upgrade Kit MultiScope Systems*<br />

This kit upgrades the MultiScope microscopes that are<br />

currently used with Spectrum RX, Spectrum BX, Spectrum/<br />

Paragon 1000, or the 1600 Series FT-IR Spectrometers to<br />

enable them to be interfaced with a<br />

Spectrum One spectrometer.<br />

Part No. Each (€)<br />

L1200390 1611<br />

Microscope Upgrade Kit for AutoIMAGE Systems*<br />

This kit upgrades AutoIMAGE system microscopes that are<br />

currently used with Spectrum RX, Spectrum BX, Spectrum/<br />

Paragon 1000, or the 1600 Series FT-IR Spectrometers to<br />

enable them to be interfaced to a Spectrum One<br />

spectrometer.<br />

Part No. Each (€)<br />

* Spectrum GX, Spectrum 2000, and System 2000 microscopes cannot be<br />

upgraded to be used with a Spectrum One system.<br />

Germanium ATR Objective Upgrade Kit<br />

Part No.<br />

Each (€)<br />

L1200220 256<br />

L1200392 1611<br />

This kit upgrades the MultiScope System, or the<br />

AutoIMAGE System Microscope without ATR Objective<br />

to include ATR Objective facility. This is a field fit option<br />

including cassegrain, mount, and germanium micro-ATR<br />

crystal with holder. A spare germanium crystal with holder<br />

is also included.<br />

Part No. Each (€)<br />

L1860298 7900<br />

LCD Touch-Screen Upgrade<br />

Spectrum One NTS systems<br />

without an LCD touch screen can<br />

be upgraded with this kit.<br />

Left-Side FT-NIR External Beam<br />

Kit (Microscope Compatible)<br />

L1240204 1208<br />

Allows for connection of AutoIMAGE<br />

microscope system. For use with the Spectrum One NTS.<br />

Spectrum One Infrared Sample Compartment<br />

Includes Sample Base Plate, Slide Mount, and Sample<br />

Compartment Covers. Allows for traditional infrared<br />

measurements to be made on Analyzer<br />

Systems such as the Edible Oil<br />

Analyzer or Used Oil Analyzer.<br />

Part No.<br />

L1200302<br />

Each (€)<br />

2684<br />

Spectrum One/100 Sample Shuttle<br />

Allows sample to be moved in and out of infrared beam for<br />

automatic background correction<br />

during sample measurement.<br />

Part No. Each (€)<br />

Spectrum One Base-Plate<br />

Includes sample base-plate and sample slide mount. Can be<br />

used to permanently mount a sampling accessory. When the<br />

accessory is required to do an infrared measurement, the<br />

accessory and base-plate can simply<br />

be pushed into the Spectrum One<br />

sample compartment area.<br />

Part No.<br />

L1200254<br />

Each (€)<br />

425<br />

Spectrum One Left-Hand Side<br />

External Beam Upgrade<br />

Part No.<br />

Each (€)<br />

L1200223 2013<br />

Part No.<br />

Each (€)<br />

L1200301 616<br />

Spectrum One systems without an external beam merging<br />

from the left-hand side of the instrument can be upgraded<br />

with these kits.<br />

Description Part No. Each (€)<br />

KBr L1200205 1232<br />

Upgrade Kits Infrared Spectroscopy<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

265


©2005 PerkinElmer, Inc. Microsoft is a registered trademark of Microsoft Corporation in the United States and other countries. 400083_03<br />

Getting perfect results is now<br />

a walk in the park<br />

Upgrade to a better lab experience<br />

with the NEW PerkinElmer Spectrum 100 FT-IR Spectrometers<br />

Experience the Spectrum 100 FT-IR and 100N FT-NIR and enjoy all the benefits of having unparalleled<br />

quality and reliability. You’ll achieve harmony in your lab and gain perfect results with these easy-to-use<br />

instruments. The Spectrum 100 Series is packed with everything you need to succeed and backed by<br />

the expertise of PerkinElmer ® , so you can breathe easier every single day.<br />

See how the Spectrum 100 Series delivers the performance and reliability essential to your lab.<br />

Just go to www.perkinelmer.com/spectrum100<br />

Or, call 1 800-762-4000 (North America) or (+1) 203-925-4602<br />

Visit www.perkinelmer.com/lasoffices for a listing of our global offices.


PerkinElmer offers a comprehensive line of<br />

High Performance Liquid Chromatography (HPLC)<br />

systems to meet your lab’s every requirement. The<br />

PerkinElmer Series 200 HPLC family was designed<br />

to meet and exceed the liquid chromatography<br />

demands of your lab. It offers a fully modular<br />

scalable system structure – meaning no compromises<br />

on functionality or performance. Best of all,<br />

every PerkinElmer instrument is backed by our<br />

renowned global service and support organization.<br />

Liquid Chromatography<br />

Acquiring, processing, reporting, reviewing<br />

and approving data are a streamlined series<br />

of operations in PerkinElmer’s TotalChrom ®<br />

Chromatography Data System (CDS) software,<br />

designed to fit your laboratory workflow and<br />

maximize productivity. TotalChrom data systems<br />

can be deployed in stand-alone, thin client or<br />

enterprise client/server computing environments.


Liquid Chromatography<br />

QUICK-FIND INDEX Page #<br />

Autosampler Trays 270<br />

Autosampler Vials, Caps<br />

and Septa 271<br />

PerkinElmer offers a wide selection of superior quality products designed to work with<br />

your PerkinElmer instruments. Our precision-designed products deliver the peace of<br />

mind that comes from knowing that you’ll get the results you need.<br />

The Quick Find Index to the left will help you find products fast. For your convenience,<br />

products are alphabetized by category, sub-category, and family. There is also a more<br />

complete Alphabetical INDEX on page 429 and a Part Number INDEX on page 407.<br />

Cartridge Columns 274<br />

Check Valves 319<br />

Conventional Columns 294<br />

Conventional Guard Cartridges<br />

and Accessories 313<br />

Degassing Systems 318<br />

Detector Lamps 316<br />

Deuterium Lamps<br />

PerkinElmer Deuterium Lamps for the Series 200 UV/Vis<br />

Detector, provide outstanding performance and longevity.<br />

Deuterium lamps are warranteed for at least 500 hours of<br />

operation. Lamp replacement is quick and easy due to a<br />

self-aligning lamp mount.<br />

Page 316<br />

Detectors 314<br />

Dynamic Mixers 321<br />

Fittings 323<br />

ISS-200 Supplies 273<br />

LC Column Ovens 317<br />

Peltier Trays 270<br />

Pistons and Piston Seals 319<br />

Pump Accessories 321<br />

Rheodyne Injection Valves 324<br />

Sample Introduction 327<br />

Supplies and Accessories 323<br />

Syringes 273<br />

TotalChrom Chromatography<br />

Software 328<br />

Autosampler Vials, Caps, and Septa<br />

Brownlee Columns<br />

PerkinElmer Autosampler vials and caps are guaranteed to<br />

fit and are compatible with the Series 200 Autosampler.<br />

Vials and caps are inert to samples ordinarily analyzed by<br />

Liquid Chromatography. Septa are designed specifically for<br />

autosampler needle to prevent bending, breakage, or coring<br />

of the septa.<br />

Page 271<br />

Brownlee TM Conventional and Cartridge Columns for Reversed<br />

Phase, Normal Phase and Ion Exchange Chromatography<br />

modes of separation. Conventional columns use standard<br />

compression end fittings compatible with all HPLC<br />

instrumentation. Each column is individually tested. Brownlee Cartridge Columns are<br />

available in three lengths and two internal diameters. The MPLC cartridge system<br />

allows direct coupling of a cartridge to a guard without any dead volume. NewGuard ®<br />

Cartridge Columns prolong column life two to five fold by eliminating particulates<br />

and contaminant's.<br />

Page 274<br />

Online Vacuum Degassing Systems<br />

Extend the performance of your pump by using a Degassing<br />

System. The Series 200 Vacuum Degasser is a low-volume,<br />

high efficiency, online module for removal of dissolved gasses<br />

from HPLC solvents. The vacuum degasser is available in<br />

three and five channel models to support isocratic, binary<br />

and quaternary pumps as well as degassing of autosampler<br />

flush solvent.<br />

Page 318


PerkinElmer Series 200<br />

HPLC Systems<br />

Designed to<br />

Never<br />

Let You Down<br />

HPLC Series 200<br />

PerkinElmer knows you need to rely<br />

on your high performance liquid<br />

chromatography (HPLC) system to<br />

get the job done day-in and day-out.<br />

That’s why we designed and built the<br />

Series 200 system of HPLC instruments.<br />

We’re confident the Series 200 HPLC<br />

systems will meet and exceed the liquid<br />

chromatography demands of your lab,<br />

because each component – from pump<br />

to data handling – has a proven track<br />

record behind it. Best of all, all of our<br />

systems are backed by our renowned<br />

global service and support organization,<br />

so you know you can depend on them<br />

today, tomorrow, and for years to come.<br />

SoftLINK TM : entry-level solution<br />

for instrument connectivity<br />

Designed for instrument workstation<br />

environments, SoftLINK provides<br />

instrument connectivity at a glance.<br />

dotLINK TM : interfacing with ease<br />

dotLINK is a Windows CE-based<br />

interface that allows you to connect<br />

your Series 200 directly to the<br />

network. Designed to face today’s<br />

workload challenges and provide<br />

Ethernet connectivity, dotLINK allows<br />

external buffering with a minimal<br />

need for validation.<br />

269


Liquid Chromatography Autosampler Supplies and Accessories<br />

Autosampler Supplies and Accessories<br />

Autosampler Trays and Plates<br />

Peltier Tray Accessories<br />

100-Position Peltier Temperature-Controlled<br />

Tray Accessory<br />

100 standard 2 mL vials. Temperature controlled from<br />

4-60° C within ± 1° C directly from Autosampler keypad –<br />

or from TotalChrom Workstation – Client/Server.<br />

Double Microtiter Peltier<br />

Temperature-Controlled Tray Accessory<br />

Two shallow or medium depth microtiter plates. Temperature<br />

controlled from 4-60° C within ± 1° C directly from Autosampler<br />

keypad – or from TotalChrom Workstation – Client/Server.<br />

(Also requires N2930036).<br />

Part No. Each (€)<br />

Peltier Temperature Controller<br />

Controller Unit required for operation<br />

of either 100-position or Double<br />

Microtiter Peltier trays.<br />

Part No.<br />

Part No.<br />

Each (€)<br />

N2930035 1454<br />

N2930037 1454<br />

Each (€)<br />

N2930036 1849<br />

Series 200 Autosampler Microtiter Trays and Plates<br />

100-Position Peltier Temperature-Controlled Tray Accessory<br />

Part No. N2930035<br />

Sample Trays<br />

PerkinElmer has researched, engineered, and developed<br />

the Series 200 Autosampler to ensure precision, flexibility,<br />

reliability, and ease-of-use.<br />

Our unique XYZ design allows you to take advantage<br />

of the built-in “extra” capabilities including dilution,<br />

derivatization, and standard addition – all without<br />

additional hardware or cost.<br />

Description Part No. Each (€)<br />

25-Position Sample Tray N2930040 351<br />

80-Position Sample Tray, Dilution (with tank) N2930314 625<br />

Includes: 80-Position Tray Only N2930044 395<br />

Glass Diluent Tank Only B0505677 398<br />

85-Position Sample Tray, Derivatization N2930041 351<br />

100-Position Sample Tray N2931097 351<br />

205-Position Sample Tray, Microvials/10 standard vials N2930042 351<br />

225-Position Sample Tray, Microvials/high throughput N2930043 351<br />

If you need high throughput and high speed, the Series 200 is designed for injecting up to 225 samples at rates as fast as<br />

two to three injections per minute from any sample position – ideal for LC/MS work. The Series 200 even supports direct<br />

injections from microtiter plates – shallow or deepwell format.<br />

Tray Description Part No. Each (€) Microtiter Plates Description Part No. Each (€)<br />

Double Deep Microtiter Tray N2930147 332 96-well Deep (1mL) N9302560 8<br />

(Holds two 96-well Plates) 96-well Plate Cover/Mat N9302563 5<br />

Double Microtiter Peltier Tray N2930037 1454 96-well Shallow (200 μL) N9302562 5<br />

Requires Peltier Controller (N2930036) 96-well Mid (500 μL) N9302561 7<br />

(Holds two 96-well Plates) 96-well Plate Cover/Mat N9302563 5<br />

Double Shallow Microtiter Plate Tray N2930146 332 96-well Shallow (200 μL) N9302562 5<br />

(Holds two 96-well Plates) 96-well Mid (500 μL) N9302561 7<br />

96-well Plate Cover/Mat N9302563 5<br />

Peltier Tray for 384-well Microtiter Plates N2930038 1454 384-well Plate (200 μL) N9302564 10<br />

Requires Peltier Controller (N2930036) and 384-well Plate Cover/Mat N9302565 197<br />

Series 200 Autosampler Firmware 1.08 or higher.<br />

270


0.2 mL Micro Vials,<br />

Caps, and Septa<br />

Caps/Septa<br />

Description Part No. Each (€)<br />

Polyethylene press-on cap for 8 mm o.d. vials N9302141 140<br />

(pkg. 1000)<br />

Aluminum crimp-top cap with Teflon-lined butyl 03300806 171<br />

rubber septa for 8 mm vials (pkg. 1000)<br />

Crimp Top Vials<br />

Glass microVials, tapered,<br />

0.2 mL, 8 mm o.d. top. (pkg. 500)<br />

Glass Autosampler Vial Sleeve<br />

Polyethylene Micro Vial Kit<br />

Includes 300 μL tapered vial, blue<br />

polypropylene cap with bonded<br />

silicone/PTFE septa. (pkg. 500)<br />

2.0 mL Vials, Caps and Septa<br />

PerkinElmer Autosampler vials are guaranteed for fit and<br />

compatibility with the Series 200 Autosampler. Both vials<br />

and caps are totally inert to samples ordinarily analyzed by<br />

Liquid Chromatography.<br />

Crimp Caps<br />

Description Size Part No. Each (€)<br />

Crimp Green (pkg. 100) 11 mm N9302684 35<br />

Aluminum cap with Teflon ® /rubber<br />

Crimp Red (pkg. 100) 11 mm N9302685 37<br />

Aluminum cap with Teflon/rubber<br />

Series 200 Autosampler<br />

Autosampler Supplies and Accessories<br />

Part No.<br />

Each (€)<br />

N9302136 357<br />

Part No.<br />

Each (€)<br />

N9307027 159<br />

Part No.<br />

Each (€)<br />

N9306080 557<br />

Compatibility Table for Vials and Caps in Sample Trays<br />

Autosampler Vials and Caps<br />

Description Size Part No. Each (€)<br />

Crimp Blue (pkg. 100) 11 mm N9302686 41<br />

Aluminum cap with Teflon/rubber<br />

Crimp Silver (pkg. 100) 11 mm N9306015 25<br />

Aluminum cap with Teflon/rubber<br />

Crimp Top Vials<br />

Type 1 borosilicate standard glass vials, 2.0 mL,<br />

11 mm o.d. top.<br />

Description Part No. Each (€)<br />

Amber glass (pkg. 100) N9302680 31<br />

Clear glass (pkg. 100) N9301385 18<br />

Screw Top Vials and Caps – Wide Mouth<br />

Type 1 borosilicate standard glass vials,<br />

2.0 mL, 12 x 32 mm.<br />

Description Size Part No. Each (€)<br />

Amber Glass (pkg. 100) N9306057 20<br />

Clear Glass (pkg. 100) N9306053 19<br />

Screw Black (pkg. 100) 10 mm N9306052 45<br />

Polypropylene with PTFE/slit<br />

white silicone<br />

6 mL Vials and Caps<br />

Part No.<br />

Part No.<br />

Each (€)<br />

N9302143 56<br />

Each (€)<br />

N9302134 101<br />

Vials<br />

Caps<br />

Volume Series 200 Tray Part No. Each (€) Part No. Each (€)<br />

0.2 mL* 205-Position N9302136 357 N9302141 140<br />

225-Position<br />

2.0 mL - Crimp Top 81-Position N9302680 31 N9302684 35<br />

85-Position N9301385 18 N9302685 37<br />

100-Position N9302686 41<br />

105-Position Peltier N9306015 25<br />

205-Position<br />

2.0 mL - Screw Top 81-Position N9306053 19 N9306052 45<br />

85-Position N9306057 20<br />

100-Position<br />

100-Position Peltier<br />

205-Position<br />

6.0 mL 25-Position N9302134 101 N9302143 56<br />

85-Position<br />

* Requires N9307027 sleeves<br />

Caps/Septa<br />

Polyethylene press-on cap<br />

for 20 mm o.d. vials. (pkg. 250)<br />

Crimp Top Vials<br />

Glass large-volume vials,<br />

6.0 mL, 20 mm o.d. top. (pkg. 125)<br />

Autosampler Supplies and Accessories Liquid Chromatography<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

271


Liquid Chromatography Autosampler Supplies and Accessories<br />

Autosampler Supplies and Accessories<br />

Autosampler Vial Crimping Tools<br />

Crimpers<br />

PerkinElmer also provides crimpers for a variety of cap<br />

sizes. Crimp capping is still a preferred method by some<br />

laboratories to ensure sample integrity, particularly those<br />

containing volatile compounds.<br />

Bench Top Vial Crimper<br />

Without jaws.<br />

Bench Top Vial Crimper Jaws<br />

For 11 mm vials.<br />

Bench Top Vial Crimper Jaws<br />

For 20 mm vials.<br />

Economy Cap Removal Tool<br />

20 mm.<br />

Vial Crimper<br />

For 11 mm o.d. top vials.<br />

Part No.<br />

Each (€)<br />

N6621006 1685<br />

Part No.<br />

Each (€)<br />

N6621008 391<br />

Part No.<br />

Each (€)<br />

N6621009 344<br />

Part No.<br />

Each (€)<br />

N9301270 64<br />

Part No.<br />

Each (€)<br />

00090699 263<br />

Electronic Crimpers<br />

New from PerkinElmer, the 11 mm electronic crimpers<br />

and decappers are easy to use and fully rechargeable.<br />

Ergonomically designed to alleviate the potential for carpal<br />

tunnel syndrome and provide a consistent crimp pressure<br />

numerous times. The electronic crimper is provided with<br />

a standard Black and Decker VersaPak ® Gold battery and<br />

charging unit. This handheld device will crimp several<br />

hundred vials on one charge. Crimping pressure is fully<br />

adjustable for precision control. Also available in 20 mm.<br />

Features and Benefits:<br />

Precision control crimping<br />

Ergonomically designed grip<br />

Numerous reproducible crimps<br />

from a single charge<br />

Includes standard Black and Decker<br />

VersaPak Gold battery and charger<br />

Description Voltage Part No. Each (€)<br />

11 mm Electronic Crimper 120 V N9302567<br />

11 mm Electronic Crimper 230 V N9302569 700<br />

11 mm Electronic Crimper 240 V N9302570 700<br />

11 mm Electronic Decapper 120 V N9302575<br />

11 mm Electronic Decapper 230 V N9302577 700<br />

11 mm Electronic Decapper 240 V N9302579 700<br />

Electric Crimper Battery N9302585 44<br />

272


Autosampler Syringes Series 200<br />

Description Size Part. No. Each (€)<br />

Sampling Syringe 50 μL 09923304 281<br />

Sampling Syringe 100 μL 09923305 281<br />

Sampling Syringe 250 μL 09923270 281<br />

Sampling Syringe 500 μL 09923306 281<br />

Sampling Syringe 1000 μL 09923307 281<br />

Sampling Syringe 2500 μL 09923219 281<br />

Requires one-time purchase of<br />

Sampling Syringe Kit (N2930313)<br />

Sampling Syringe Kit 2500 μL N2930313 281<br />

Includes: 2500 μL syringe, union,<br />

and tubing kit<br />

Flush Syringe 2500 μL 09923219 281<br />

\<br />

BCD Cables<br />

Series 200 Autosampler 1022 BCD Cable<br />

REM Box.<br />

Series 200 Autosampler TotalChrom TM /<br />

Turbochrom TM BCD Cable<br />

900 Interface.<br />

ISS-200 Injector Valve<br />

Parts for BSW Valves<br />

Description Part No. Each (€)<br />

Rotor Seal B0185480 91<br />

Stator B0162836 229<br />

ISS-200 Sample Trays<br />

Description Part No. Each (€)<br />

100-Position Sample Tray B0198017 930<br />

150-Position Sample Tray B0198016 640<br />

Autosampler Supplies and Accessories<br />

Part No.<br />

Part No.<br />

Each (€)<br />

N2930341 295<br />

Each (€)<br />

N2930340 242<br />

ISS-200 and Series 200 Autosampler<br />

ISS-200 Spares<br />

Description Part No. Each (€)<br />

Dosing Pump (250 μL) B0193780 2420<br />

Dosing Pump (1500 μL) B0506592 1761<br />

Dosing (Sample) Pump Piston (250 μL) B0092468 349<br />

Dosing Pump Piston Seal (250 μL) B0133956 175<br />

Flush Pump Inlet Check Valve B0105973 437<br />

Flush Pump Outlet Check Valve B0105974 359<br />

Flush Pump Piston B0092456 372<br />

Flush Pump Piston Head B0170873 465<br />

Flush Pump Piston Seal B0170875 42<br />

Flush Solvent Filter B0193766 137<br />

with Teflon ® tubing, nuts, and ferrules<br />

PerkinElmer Injection Valve Assembly B0185259 2771<br />

(w/150 μL loop)<br />

Sampling Needle 02540582 99<br />

Serial Dilution Tank B0505677 398<br />

Teflon Transfer Tube 02506495 1<br />

Tefzel Sample Transfer Tube B0121084 49<br />

for Prep Option Kit<br />

Manuals<br />

User’s Manual Series 200<br />

User’s Manual ISS-200<br />

Replacement Parts Series 200<br />

Part No.<br />

Each (€)<br />

09938912 97<br />

Part No.<br />

Each (€)<br />

B0198180 790<br />

Description Size Part. No. Each (€)<br />

Delrin Nut 1/16 in. 09920381 7<br />

Fingertight Nut (qty. 1) 09920513 17<br />

Flush Reservoir Filter 40 μm SS 09903615 68<br />

Flush Reservoir Filter 40 μm Ti N2600089 75<br />

Needle Cartridge Cap Screw N2931064 38<br />

Needle Cartridge Casting N2931012 197<br />

Needle Cartridge Thumb Screw 09920672 6<br />

Needle Spring 09920429 1<br />

Stainless Steel Injector Needle N2930023 140<br />

Stainless Steel Sample Holding Loop N2930311 281<br />

Teflon Transfer Line Per Ft 02506495 1<br />

Tefzel Reverse Ferrule 1/16 in. 09920382 4<br />

Tefzel Union 09920391 34<br />

no nuts or ferrules<br />

Titanium Injector Needle N2930024 389<br />

Titanium Sample Holding Loop N2930312 414<br />

Union 1/16 in. 09903289 92<br />

Union Holder Arm N2931081 35<br />

Note: See the Rheodyne Valve section for injection valves spares<br />

Autosampler Supplies and Accessories Liquid Chromatography<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

273


Cartridge Columns<br />

Brownlee Cartridge Columns<br />

Analytical Cartridges for<br />

Conventional and Narrowbore HPLC*<br />

Analytical cartridges from the Brownlee TM line are available in three<br />

lengths (30, 100, and 220 mm), and two internal diameters (4.6 and<br />

2.1 mm). The MPLC cartridge system allows direct coupling of a<br />

cartridge to a guard without any dead volume. Changing cartridges<br />

is easy with the finger-tight cartridge design which does not require<br />

any wrench-tightening of the holder or disconnecting of tubing<br />

from the LC system. A specific cartridge holder is required for each<br />

cartridge length. Additional information on MPLC holders can<br />

be found on page 293. Pressure ratings are 7,000 psi for silicabased<br />

columns.<br />

■ Quality: Columns are manufactured under stringent ISO-9001 certified<br />

quality control standards. Individual test chromatograms are included<br />

with each 100 mm and 220 mm cartridge.<br />

■ Flexible: Same reusable holder for 4.6 and 2.1 mm i.d. cartridges.<br />

Compatible with all HPLC instruments. Choice of different cartridge<br />

lengths to enhance speed or resolution.<br />

■ Economical: Cartridges are less expensive than conventional columns.<br />

Solvent consumption reduced by using narrowbore or shorter columns.<br />

■ Experience: 25 years of manufacturing experience since Bob Brownlee<br />

introduced the first finger-tight cartridge system in 1977.<br />

* Microbore, semi-preparative and conventional MPLC columns<br />

found on pages 290.<br />

Brownlee Sorbents<br />

Brownlee offers a wide selection of sorbents based on both silica<br />

and polymer supports.<br />

Aquapore ® is a wide-pore (300 Å, 7, and 20 μm), silica-based<br />

support suitable for the separation of large biopolymers.<br />

Spheri-5 ® is a small-pore (80 Å, 5 μm), silica-based sorbent for<br />

separating small molecules. Both monofunctional (comb-type)<br />

and polyfunctional (polymerized loop-type) C8 and C18 sorbents<br />

are available.<br />

Polypore ® is a polymer-based (microporous, 10 μm) sorbent<br />

for the analysis of organic acid and sugars.<br />

Validated is a small-pore (100 Å, 5 μm) silica-based C18<br />

sorbent for small molecules, specifically for consistent<br />

pharmaceutical assays.<br />

Brownlee Columns and Holders<br />

Reduced Activity is a small-pore, base-deactivated (100 Å, 3,<br />

and 5 μm) silica-based, reversed-phase sorbent (C18 or C8)<br />

developed for HPLC of basic analytes and pharmaceuticals.<br />

CHOICE is a small-pore, base-deactivated (100 Å, 3 μm C18)<br />

silica-based, reversed-phase sorbent (C18) developed for<br />

LC/MS separations.<br />

Modes of Separation<br />

Reversed-Phase Chromatography (RPC) is the most popular HPLC<br />

mode and is used in 60-80% of all applications. In RPC, hydrophobic<br />

groups (C18, C8, or C4) bonded to a silica support are used together<br />

with a mobile phase of water and organic solvent<br />

(e.g. methanol, acetonitrile).<br />

Polar Phase (Normal Phase) Chromatography (NPC) uses a polar<br />

stationary phase (unbonded silica, bonded amino or cyano group)<br />

together with a nonpolar mobile phase (e.g., hexane). NPC is useful<br />

for functional group analysis, isomeric separations, purification of<br />

organics, and sample cleanup.<br />

Ion-Exchange Chromatography (IEC) utilizes bonded ionic groups to<br />

separate ionic analytes. Retention is based on the affinity of various<br />

analyte ions for the stationary phase and various mobile phase<br />

parameters (e.g., pH, ionic strength).<br />

Pecosphere is a small-pore (80 Å, 3, 5, and 10 μm) silica-based<br />

sorbent for HPLC of small molecules.<br />

274


Column Selection Guide<br />

Cartridge Columns<br />

Brownlee Cartridge Column Selection and Specification Guide<br />

Molecular Weight Solubility Mode Sorbent<br />

2000 Water Ion exchange Aquapore AX-300<br />

Wide-pore reversed phase Aquapore OD-300, RP-300, BU-300<br />

Column Selection Guide for Biological Applications<br />

Molecular Weight<br />

Mode<br />

Proteins Wide-pore reversed phase Aquapore OD-300, RP-300, BU-300<br />

Ion exchange<br />

Aquapore AX-300<br />

Peptides Reversed phase Validated , Peco Red. Act.-3 and 5, CHOICE<br />

Wide-pore reversed phase Aquapore OD-300, RP-300, BU-300<br />

Ion exchange<br />

Aquapore AX-300<br />

Amino acids Reversed phase Spheri-5 RP-18, Validated<br />

Oligonucleotides, Nucleotides Wide-pore reversed phase Aquapore OD-300, RP-300, Speri-5 RP-18, CHOICE<br />

Ion exchange<br />

Aquapore AX-300<br />

Nucleosides Reversed phase Spheri-5 RP-18, CHOICE<br />

Organic acids Mixed mode Polypore H<br />

Sugars Mixed mode Polypore CA<br />

Specific Recommendations<br />

■<br />

■<br />

■<br />

■<br />

■<br />

■<br />

■<br />

Pharmaceutical/Clinical: Validated, Red. Act.-3<br />

Protein/Peptides: Aquapore OD-300, RP-300, BU-300<br />

DNAs/Polynucleotides: Aquapore RP-300<br />

Industrial/Food: Spheri-5, Pecosphere, Red. Act.-3<br />

Environmental: Spheri-5, Pecosphere, Red. Act.-3<br />

Sugars: Spheri-5 Amino, Polypore CA<br />

Organic Acids/Alcohols: Polypore H<br />

Cartridge Columns Liquid Chromatography<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

275


Cartridge Column Applications<br />

Column Application Notes<br />

Liquid Chromatography Cartridge Column Applications<br />

Subject<br />

Page No.<br />

Biotechnology<br />

Human Serum Profile 277<br />

Nucleosides and Bases 277<br />

Organic Acids 277<br />

Tryptic Digest of Glycoprotein Human IgA 277<br />

Clinical<br />

Barbiturates 278<br />

Theophylline 278<br />

Environmental<br />

Diquat and Paraquat 278<br />

Phenol Priority Pollutants 278<br />

Food<br />

Analysis of OPA Precolumn Derivatives of Amino Acids 279<br />

Analysis of Sugars (resin column) 279<br />

Analysis of Organic Acids 279<br />

Fat-soluble Vitamins in Animal Feeds 279<br />

Olive Oil Triglycerides 280<br />

Organic Acids in Fruit Juice 280<br />

Sweetener in Beverage 280<br />

Water-Soluble Vitamins in Animal Feeds 280<br />

Industrial<br />

Epoxy Resin 281<br />

Hexachlorophene 281<br />

Polystyrene Additives 281<br />

Short-Chain Fatty Acids 281<br />

Pharmaceutical<br />

Analgesics in Tablets 282<br />

Analgesics/Anti-inflammatory 282<br />

Antihistamines 282<br />

Benzodiazepines 282<br />

Carbamazepine in Serum 283<br />

Cardiac Drugs 283<br />

Chlorthalidone HPLC Assay 283<br />

Estrogenic Steroids 283<br />

Parabens in Hand Cream 284<br />

Phenothiazines 284<br />

Prednisone in Tablet Prep 284<br />

The LC/MS of Quinolone Antibiotic Degradation Products 284<br />

276


Cartridge Column Applications<br />

Biotechnology Applications<br />

Human Serum Profile<br />

1<br />

CHROMATOGRAPHIC CONDITIONS<br />

Column: Pecosphere 5 C18 (150 x 4.6 mm, 5 μm)<br />

Detection: UV at 254 nm<br />

Mobile Phase: A: 60% MeOH/H 2 O<br />

B: 0.02 M NaH 2 PO 4 in pH 5.6<br />

Linear gradient from 0.5% – 40% A in 7 min.<br />

Flow Rate: 2.0 mL/min.<br />

Pressure: 2,200 psi (15 MPa)<br />

Inj. Volume: 10 μL of deproteinized serum<br />

Nucleosides and Bases<br />

Peak Identification<br />

2 4<br />

5<br />

3<br />

1. Cytosine<br />

2. Uracil<br />

3. Cytidine<br />

4. Uridine<br />

5. Hypoxanthine<br />

6. Xanthine<br />

7. Thymine<br />

8. Inosine<br />

9. Guanosine<br />

10. Thymidine<br />

11. Adenine<br />

12. Adenosine<br />

6<br />

7<br />

8<br />

Peak Identification<br />

CHROMATOGRAPHIC CONDITIONS<br />

Column: Pecosphere 5 C18 (150 x 4.6 mm, 5 μm)<br />

Detection: UV at 254 nm<br />

Mobile Phase: A: 60% MeOH/H 2 0<br />

B: 0.02 M NaH 2 PO 4 in pH 5.5 aqueous buffer<br />

gradient 0.5% – 40% A in 3 min.<br />

Flow Rate: 3.5 mL/min.<br />

Pressure: 3,500 psi (24 MPa)<br />

1. Creatinine<br />

2. Uric Acid<br />

3. Tyrosine<br />

4. Hypoxanthine<br />

5. Undine<br />

6. Xanthine<br />

7. Inosine<br />

8. Guanosine<br />

9. Tryptophan<br />

10. Theobromine<br />

11. Caffeine<br />

0 5 10<br />

MINUTES<br />

9<br />

10<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

0 2 4<br />

MINUTES<br />

7<br />

8<br />

10<br />

9<br />

11<br />

11<br />

12<br />

Organic Acids<br />

Peak Identification<br />

1. Oxalic Acid<br />

2. Citric Acid<br />

3. α-Ketoguitaric<br />

Acid<br />

4. Malic Acid<br />

5. Succicinic Acid<br />

6. Formic Acid<br />

7. Acetic Acid<br />

8. Fumaric Acid<br />

9. Butyric Acid<br />

CHROMATOGRAPHIC CONDITIONS<br />

Column: Polypore H (220 x 4.6 mm i.d.)<br />

Detection: 210 nm<br />

Mobile Phase: 0.01 N H 2 SO 4<br />

Flow Rate: 0.15 mL/min.<br />

Temperature: 25 °C<br />

Part No. 02580169 Part No. 07110089<br />

Part No. 02580169<br />

Tryptic Map of Glycoproteins Human IgA<br />

ABSORBANCE<br />

1<br />

2<br />

3 4<br />

5<br />

6<br />

7<br />

0 10 20<br />

MINUTES<br />

0 10 20 30 40 50<br />

MINUTES<br />

CHROMATOGRAPHIC CONDITIONS<br />

Column: Aquapore RP-300 (7 μm, 300 Å, 220 x 2.1 mm)<br />

Detection: UV at 214 nm<br />

Mobile Phase: A: 0.1% TFA<br />

B: 0.1% TFA in ACN<br />

Flow Rate: 0.25 mL/min.<br />

Gradient: 2-70% B in 45 min.<br />

Sample: Tryptic digest of glycoprotein Human IgA 200 pmoles<br />

Part No. 07110060<br />

8<br />

9<br />

Cartridge Column Applications Liquid Chromatography<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

277


Cartridge Column Applications<br />

Clinical and Environmental Applications<br />

Liquid Chromatography Cartridge Column Applications<br />

Barbiturates<br />

Peak Identification<br />

1. Barbital<br />

2. Phenobarbital<br />

3. Aprobarbital<br />

4. Butabarbital<br />

5. Mephobarbital<br />

6. Amobarbital<br />

7. Pentobarbital<br />

8. Secobarbital<br />

CHROMATOGRAPHIC CONDITIONS<br />

Column: Pecosphere-3 x 3 C18 (33 x 4.6 mm i.d.)<br />

Detection: UV at 200 nm<br />

Mobile Phase: MeOH, 0.015 M (NH 4 ) 2 HPO 2 :H 2 O (55:20:25)<br />

Flow Rate: 2.5 mL/min.<br />

Sample: 3 μL injection: 0.1 mg/mL of each barbiturate<br />

Part No. 02580164<br />

Diquat and Paraquat<br />

ABSORBANCE<br />

310 nm<br />

1<br />

255 nm<br />

0 2 4<br />

MINUTES<br />

1<br />

2<br />

3<br />

4<br />

5<br />

0 1<br />

MINUTES<br />

CHROMATOGRAPHIC CONDITIONS<br />

Column: Two Pecosphere 3 x 3, silica (83 x 4.6 mm i.d., 3 μm)<br />

Detection: UV at 310 for diquat and 255 for paraquat<br />

Mobile Phase: Tetramethyl ammonium hydroxide 10 g/L,<br />

ammonium sulfate 30 g/L (in water)<br />

Flow Rate: 0.8 mL/min.<br />

Sample: 10 ng per component<br />

Temperature: 70 °C<br />

Part No. 02580167<br />

2<br />

3<br />

6<br />

7<br />

8<br />

Peak Identification<br />

1. Diquat<br />

2. Paraquat<br />

3. Ethylparaquat<br />

(internal standard)<br />

Phenol Priority Pollutants<br />

Peak Identification<br />

1. Phenol<br />

2. p-Nitrophenol<br />

3. o-chlorophenol<br />

4. 2, 4-Dinetrophenol<br />

5. o-Nitrophenol<br />

6. 2, 4 Dimethylphenol<br />

7. 4-Chloro-m-Cresol<br />

8. 2, 4-dichlorophenol<br />

9. 4, 6-Dinitro-o-Cresol<br />

10. 2, 4, 6-Trichlorophenol<br />

11. Pentachlorophenol<br />

CHROMATOGRAPHIC CONDITIONS<br />

Column: Pecosphere 3 C18 (83 x 4.6 mm i.d., 3 μm)<br />

Detection: UV at 254 nm<br />

Mobile Phase: Linear gradient of 35% acetonitrile/water (pH 2.2)<br />

to 100% acetonitrile in 4 min.<br />

Flow Rate: 2.5 mL/min.<br />

Inj. Volume: 6 μL injection volume; 0.1-0.2 mg/mL of each compound<br />

Part No. 02580166<br />

Theophylline<br />

Peak Identification<br />

1. Theobromine<br />

2. Theophyline<br />

3. ß-OH Ethyl Theophylline<br />

4. Caffeine<br />

CHROMATOGRAPHIC CONDITIONS<br />

Column: Pecosphere-3 x 3 C18 (33 x 4.6 mm i.d.)<br />

Detection: UV at 273 nm<br />

Mobile Phase: 11% CH 3 CN in H 2 O<br />

Flow Rate: 3.0 mL/min.<br />

Sample: 6 μL injection: 1-10 mg/L standards<br />

Part No. 02580164<br />

1<br />

2<br />

4<br />

3<br />

0 1 2 3 4 5<br />

MINUTES<br />

1<br />

5<br />

2<br />

6<br />

9<br />

7<br />

8<br />

3<br />

10<br />

0 15 30 45<br />

SECONDS<br />

4<br />

11<br />

278


Cartridge Column Applications<br />

Food Applications<br />

Absorbance (210 nm)<br />

Analysis of Organic Acids<br />

Org. Acid<br />

Acetic acid 80<br />

(mg/mL)<br />

CHROMATOGRAPHIC CONDITIONS<br />

Column: Polypore H (220 x 4.6 mm, 10 μm)/Polypore H guard<br />

column (30 x 4.6 mm)<br />

Detection: UV at 210 nm<br />

Mobile Phase: 0.01N H 2 SO 4<br />

Flow Rate: 0.3 mL/min. at room temp., 300 psi<br />

Sample: 5 μL of standard or vinegar sample diluted 1:4 in mobile phase<br />

Analysis of OPA Precolumn Derivatives of<br />

Amino Acids<br />

FLUORESCENCE<br />

White Vinegar<br />

Standard<br />

Asp<br />

oxalic<br />

Glu<br />

tartaric<br />

malic<br />

Ser<br />

CHROMATOGRAPHIC CONDITIONS<br />

Column: Pecosphere 3 x 3 C18 (33 x 4.6 mm i.d., 3 μm)<br />

Detection: Fluorescence 340 nm (Ex)/450 nm (Em)<br />

Mobile Phase: A: Methanol<br />

B: 1.5% THF in 50 mM NaOAc (pH 5.9)<br />

Linear gradient of 5% A to 80% A in 6.5 min.<br />

Flow Rate: 2.5 mL/min.<br />

Sample: Soy protein hydrolyzate sample derivatized with OPA<br />

Gly<br />

His<br />

succinic<br />

0 2 4 6 8 10 12 14<br />

MINUTES<br />

Part No. 07110089/07110085<br />

Arg<br />

Thr<br />

Ala<br />

Tyr<br />

Val<br />

Phe<br />

Leu<br />

0 4 8<br />

MINUTES<br />

Part No. 02580164<br />

formic<br />

acetic<br />

acetic<br />

propionic<br />

butyric<br />

Lys<br />

UV ABSORBANCE<br />

Analysis of Sugars<br />

RI Intensity<br />

CHROMATOGRAPHIC CONDITIONS<br />

Column: Polypore CA (220 x 4.6 mm, 10 μm)/Polypore CA guard<br />

column (30 x 4.6 mm)<br />

Detection: RI<br />

Mobile Phase: Water<br />

Flow Rate: 0.2 mL/min. at 75 °C, 100 psi<br />

Sample: 10 μL of standard or juice sample diluted 1:4 in water<br />

Fat-soluble Vitamins in Animal Feed Premix<br />

Feed Premix<br />

265 nm<br />

Grape Juice<br />

Apple Juice<br />

Standards<br />

0 10 20<br />

MINUTES<br />

1<br />

1<br />

sucrose<br />

2<br />

2<br />

glucose<br />

sucrose<br />

glucose<br />

sucrose<br />

glucose<br />

FSV Standards<br />

1. Vitamin A Acetate<br />

2. Vitamin D 2<br />

3. Vitamin E<br />

4. Vitamin E Acetate<br />

0.0 5.0 10.0 15.0<br />

MINUTES<br />

285 nm<br />

Found<br />

fructose<br />

fructose<br />

fructose<br />

Part No. 07110095/07110091<br />

CHROMATOGRAPHIC CONDITIONS<br />

Column: Reduced-activity 3 μm C18 column (83 mm x 4.6 mm i.d., 3 μm)<br />

Detection: UV absorbance at 265/285 nm<br />

Mobile Phase: 92% methanol/water<br />

Flow Rate: 1.5 mL/min. at 35 °C<br />

Sample: Animal feed premix<br />

Part No.<br />

N9303394<br />

3<br />

sorbitol<br />

mg/g<br />

1. Vitamin A Acetate 4.50<br />

2. Vitamin D 3 0.10<br />

3. Folic Acid 0.3 65.20<br />

4<br />

4<br />

Cartridge Column Applications Liquid Chromatography<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

279


Cartridge Column Applications<br />

Food Applications<br />

Liquid Chromatography Cartridge Column Applications<br />

Olive Oil Triglycerides<br />

0 4 8 0 4 8 12<br />

MINUTES<br />

CHROMATOGRAPHIC CONDITIONS<br />

Column: Two PerkinElmer Pecosphere 3 x 8 C18 columns<br />

connected in series (83 x 4.6 mm i.d., 3 μm)<br />

Detection: Refractive Index<br />

Mobile Phase: Acetone/Acetonitrile (70:30)<br />

Flow Rate: 2.5 mL/min.<br />

Part No. 02580166<br />

Organic Acids in Fruit Juice<br />

Absorbance (210 nm)<br />

Standards<br />

Trilinolenin<br />

Tripalmitolein<br />

Orange<br />

Juice<br />

Cranberry<br />

Cocktail<br />

Standards<br />

Trilinolein<br />

Triolean<br />

(000)<br />

oxalic<br />

quinic<br />

oxalic<br />

oxalic<br />

tartaric<br />

quinic<br />

malic<br />

CHROMATOGRAPHIC CONDITIONS<br />

Column: Spheri-5 RP-18 (220 x 4.6 mm, 5 μm)<br />

Detection: UV at 210 nm<br />

Mobile Phase: 25 mM KH 2 PO 4 at pH 2.4, purge with 30%<br />

ACN for 1 min. then equilibrate for 10 min.<br />

Flow Rate: 1.5 mL/min. at room temperature, pressure 2,400 psi<br />

Sample: 5 μL of beverage sample diluted 1:4 in mobile phase<br />

Part No. 07110017<br />

ascorbic<br />

quinic<br />

malic<br />

shikimic<br />

ascorbic<br />

LPL<br />

malic<br />

lactic shikimic<br />

acetic<br />

LPO<br />

LOL<br />

LOO<br />

OOO<br />

POO<br />

POP<br />

PPP<br />

SOO<br />

SPO<br />

citric<br />

citric<br />

citric<br />

000. Triolean<br />

L. Linoleic Acid<br />

P. Palmitic Acid<br />

S. Stearic Acid<br />

succinic<br />

1.0 2.0 3.0 4.0 5.0 6.0<br />

MINUTES<br />

UV ABSORBANCE<br />

Sweeteners and Additives in Beverages<br />

Peak Identification<br />

1. Matrix<br />

2. Saccharin<br />

3. Caffeine<br />

4. Aspartame<br />

5. Vanillin<br />

6. Sodium Benzoate<br />

CHROMATOGRAPHIC CONDITIONS<br />

Column: Pecosphere 5 x 15 C18 (150 x 4.6 mm i.d., 5 μm)<br />

Detection: UV at 254 nm<br />

Mobile Phase: 45% A in B A: Methanol B: Water with 0.7 g m/L hexane<br />

sulfonic acid & H 3 PO 4 to pH 2.1<br />

Flow Rate: 1.5 mL/min.<br />

Sample: 5 μL injection of carbonated beverage product<br />

Part No. 02580169<br />

Water-Soluble Vitamins in Animal Feed Premix<br />

295 nm<br />

275 nm<br />

1<br />

2<br />

3<br />

3<br />

Standards<br />

0 5 10<br />

MINUTES<br />

CHROMATOGRAPHIC CONDITIONS<br />

Column: PerkinElmer Reduced-activity 3 μm C8 column<br />

(83 mm x 4.6 mm i.d.)<br />

Detection: UV absorbance at 275 nm<br />

Mobile Phase: 15% methanol, 85% [10 mM hexanesulfonate (Sigma),<br />

1% acetic acid, 0.13% triethylamine in water]<br />

Flow Rate: 1.5 mL/min. at 35 °C<br />

Sample: Animal feed premix<br />

Part No. 02580192<br />

4<br />

1. Vitamin C<br />

2. Niacin<br />

5<br />

Vitamin Premix Found mg/g<br />

3. Niacinamide 7.2<br />

5. Thiamine 2.3<br />

6. Folic Acid 0.3<br />

7. Riboflavin 1.7<br />

5<br />

6<br />

6<br />

1<br />

2<br />

3<br />

0 MINUTES 5<br />

4<br />

5<br />

3. Niacinamide<br />

4. Pyridoxine<br />

5. Thiamine<br />

6. Folic Acid<br />

7. Riboflavin<br />

7<br />

7<br />

6<br />

280


Cartridge Column Applications<br />

Industrial Applications<br />

Epoxy Resin<br />

0 10 20 30<br />

Minutes<br />

CHROMATOGRAPHIC CONDITIONS<br />

Column: Pecosphere 3 C18 (83 x 4.6 mm, 3 μm)<br />

Detection: UV at 230 nm<br />

Mobile Phase: Linear gradient of 40% acetonitrile/water<br />

to 100% acetonitrile in 30 min.<br />

Flow Rate: 2.5 mL/min.<br />

Pressure: 4,300 psi (30 MPa)<br />

Temperature: Ambient<br />

Inj. Volume: 6 μL<br />

Hexachlorophene<br />

Peak Identification<br />

1. Unknown<br />

2. Tri-Chlorophenol<br />

3. Unknown<br />

4. Mixed Bis-Pheno<br />

5. Hexachlorophene<br />

6. Unknown<br />

7. Unknown<br />

8. 8-Chloro-Trimer<br />

9. 9-Chloro-Trimer<br />

CHROMATOGRAPHIC CONDITIONS<br />

Column: Pecosphere 3 C18 (83 x 4.6 mm, 3 μm)<br />

Detection: UV at 300 nm<br />

Mobile Phase: A: CH3CN<br />

B: 1% CH 3 COONH 4 in MeOH/H 2 0 (77:23) Concave<br />

gradient from 0.1% A to 40% A in 9 min.<br />

Flow Rate: 1.8 mL/min.<br />

Pressure: 4,300 psi (30 MPa)<br />

Temperature: Ambient<br />

Inj. Volume: 20 μL<br />

Polystyrene Additives<br />

Peak Identification<br />

1. Acetophenone<br />

2. Cumyl Alcohol<br />

3. Methyl Styrene<br />

4. Santonox<br />

5. Dicumyl Peroxide<br />

Part No. 02580166 Part No. 02580169<br />

Inj.<br />

1<br />

2 3<br />

4<br />

5<br />

6<br />

0 5 10 15<br />

Minutes<br />

7<br />

CHROMATOGRAPHIC CONDITIONS<br />

Column: Pecosphere 5 C18 (150 x 4.6 mm, 5 μm)<br />

Detection: UV at 254 nm<br />

Mobile Phase: Linear gradient of 25% acetonitrile/water<br />

to 100% acetonitrile in 10 min.<br />

Flow Rate: 3.0 mL/min.<br />

Pressure: 3,200 psi (8 MPa)<br />

Temperature: Ambient<br />

Inj. Volume: 6 μL<br />

Short-chain Fatty Acids<br />

Peak Identification<br />

1. Formic Acid<br />

2. Acetic Acid<br />

3. Propionic Acid<br />

4. Butyric Acid<br />

CHROMATOGRAPHIC CONDITIONS<br />

Column: Pecosphere 5 C18 (150 x 4.6 mm, 5 μm)<br />

Detection: UV at 220 nm<br />

Mobile Phase: 10% CH 3 CN in water (pH 2.0)<br />

Flow Rate: 2.0 mL/min.<br />

Pressure: 2,600 psi (18 MPa)<br />

Temperature: Ambient<br />

Inj. Volume: 10 μL<br />

Part No. 02580166 Part No. 02580169<br />

8<br />

9<br />

Inj.<br />

1 2 3 4<br />

0 2 4 6 8 10<br />

Minutes<br />

1<br />

2<br />

3<br />

0 1 2 3<br />

Minutes<br />

5<br />

4<br />

Cartridge Column Applications Liquid Chromatography<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

281


Cartridge Column Applications<br />

Pharmaceutical Applications<br />

Liquid Chromatography Cartridge Column Applications<br />

Analgesic/Anti-Inflammatory<br />

Peak Identification<br />

1. Acetaminophen<br />

2. Naproxen<br />

3. Indomethacin<br />

4. Phenylbutazone<br />

5. Meclolenamate<br />

1<br />

0 10<br />

MINUTES<br />

CHROMATOGRAPHIC CONDITIONS<br />

Column: Brownlee RP-8 Spheri-5 (220 x 2.1 mm)<br />

Detection: UV at 200 nm<br />

Mobile Phase: A: 0.08% Diethylamine 0.08% Phosphoric Acid<br />

90% Acetonitrile<br />

B: 0.08% Diethylamine 0.09% Phosphoric Acid pH 2.3<br />

Gradient: 5% A for 2 min.; 5% – 100% A in 15 min.; 100% A for 5 min.<br />

Flow Rate: 0.5 mL/min.<br />

Temperature: 50 °C<br />

Part No. 07110006<br />

Analgesics in Tablets<br />

Peak Identification<br />

1. Acetaminophen<br />

2. Caffeine<br />

3. Salicylamide<br />

4. Acetylsalicylic Acid<br />

CHROMATOGRAPHIC CONDITIONS<br />

Column: Pecosphere 3 x 8 C18 (33 x 4.6 mm i.d.)<br />

Detection: UV at 250 nm<br />

Mobile Phase: 15% CH 3 CN in 0.1% H 3 PO 4<br />

Flow Rate: 2.0 mL/min.<br />

Inj. Volume:1 μL of tablet extract<br />

Part No. 02580166<br />

1<br />

2<br />

3<br />

2<br />

4<br />

3<br />

0 1 2<br />

MINUTES<br />

4 5<br />

Antihistamines<br />

Peak Identification<br />

1. Chlorpheniramine<br />

2. Diphenhydramine<br />

3. Hydroxyzine<br />

4. Meclizine<br />

0 10<br />

MINUTES<br />

CHROMATOGRAPHIC CONDITIONS<br />

Column: Brownlee RP-8 Spheri-5 (220 x 2.1 mm)<br />

Detection: UV at 200 nm<br />

Mobile Phase: A: 0.08% Diethylamine 0.08% Phosphoric Acid<br />

90% Acetonitrile<br />

B: 0.08% Diethylamine 0.09% Phosphoric Acid pH 2.3<br />

Gradient: 5% A for 2 min.; 5% – 100% A in 15 min.; 100% A for 5 min.<br />

Flow Rate: 0.5 mL/min.<br />

Temperature: 50 °C<br />

Part No. 07110006<br />

Benzadiazepines<br />

Peak Identification<br />

1. Norchlordiazepoxide<br />

2. Chlorodiazepoxide<br />

3. Oxazepam<br />

4. Nordiazepam<br />

5. Desalkyiflurazepam<br />

6. Diazepam<br />

7. Flurazepam<br />

8. Prazepam<br />

0 10<br />

MINUTES<br />

CHROMATOGRAPHIC CONDITIONS<br />

Column: Brownlee RP-8 Spheri-5 (220 x 2.1 mm)<br />

Detection: UV at 200 nm<br />

Mobile Phase: A: 0.08% Diethylamine 0.08% Phosphoric Acid<br />

90% Acetonitrile<br />

B: 0.08% Diethylamine 0.09% Phosphoric Acid pH 2.3<br />

Gradient: 5% A for 2 min.; 5% – 100% A in 15 min.; 100% A for 5 min.<br />

Flow Rate: 0.5 mL/min.<br />

Temperature: 50 °C<br />

Part No. 07110006<br />

1<br />

1<br />

2<br />

2<br />

3<br />

3<br />

4 6<br />

5<br />

7<br />

8<br />

4<br />

282


Cartridge Column Applications<br />

Pharmaceutical Applications<br />

mAU (212 nm)<br />

Carbamazepine in Serum<br />

Clinical Sample<br />

Standard<br />

O<br />

0 2 4 6<br />

MINUTES<br />

CHROMATOGRAPHIC CONDITIONS<br />

Column: Validated C18 (100 x 4.6 mm i.d.)<br />

Detection: 212 nm<br />

Mobile Phase: 55% MeOH/H 2 O<br />

Flow Rate: 1.0 mL/min.<br />

Sample: 2 μL of standard at 10 ng/μL, 2 μL of clinical serum extract<br />

Part No. 00402241<br />

Cardiac Drugs<br />

Peak Identification<br />

N<br />

CONH 2<br />

1. Procainamide<br />

2. Acetylprocainamide<br />

3. Nadolol<br />

4. Lidocaine<br />

5. Disopyramide<br />

6. Propranolol<br />

7. Nifedipine<br />

CBZE<br />

CHROMATOGRAPHIC CONDITIONS<br />

Column: RP-8 Spheri-5 (220 x 2.1 mm)<br />

Detection: UV at 200 nm<br />

Mobile Phase: A: 0.08% Diethylamine 0.08%<br />

Phosphoric Acid 90% Acetonitrile<br />

B: 0.08% Diethylamine 0.09%<br />

Phosphoric Acid pH 2.3<br />

Gradient: 5% A for 2 min.; 5% – 100% A in 15 min.; 100% A for 5 min.<br />

Flow Rate: 0.5 mL/min.<br />

Temperature: 50 °C<br />

Part No. 07110006<br />

1<br />

0 10<br />

MINUTES<br />

2<br />

3<br />

CBZ<br />

4<br />

N<br />

CONH 2<br />

CHA (int. std.)<br />

5<br />

6<br />

7<br />

N<br />

CONH 2<br />

Chlorthalidone HPLC Assay<br />

ABSORBANCE (235 nm)<br />

0.005 AU<br />

Impurity<br />

Chlorthalidone<br />

OH<br />

NH<br />

CL<br />

O SO 2 NH 2<br />

Chlorthalidone<br />

0 1 2 3<br />

MINUTES<br />

CHROMATOGRAPHIC CONDITIONS<br />

Column: Reduced activity C18 (33 x 4.6 mm i.d.)<br />

Detection: UV at 235 nm<br />

Mobile Phase: MeOH:H 2 O:HOAc (34:65:1)<br />

Flow Rate: 1.5 mL/min..<br />

Temperature: 30 °C<br />

Part No. 02580195<br />

Estrogenic Steroids<br />

Peak Identification<br />

1. Estriol<br />

2. ß-Estradiol<br />

3. α-Equilenin<br />

4. Equilin<br />

5. Estrone<br />

O<br />

CO 2 H<br />

CL<br />

CCA SO 2 NH 2<br />

CCA<br />

CBSA<br />

OCH 3<br />

NH<br />

O<br />

CBSA<br />

CHROMATOGRAPHIC CONDITIONS<br />

Column: Pecosphere-3CR C18 (4.6 x 83 mm) coupled/<br />

a Pecosphere-3 x 3CR C18 (33 x 4.6 mm)<br />

Detection: UV at 280 nm<br />

Mobile Phase: 33/67 v/v ACN/(0.5 M Phosphate Buffer<br />

Monobasic, 0.1% TEA adjusted to pH 4)<br />

Inj. Volume: 10 μL<br />

Part No. 02580194/02580195<br />

1<br />

2<br />

10 Minutes<br />

3<br />

4<br />

5<br />

CL<br />

SO 2 NH 2<br />

Cartridge Column Applications Liquid Chromatography<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

283


Cartridge Column Applications<br />

Pharmaceutical Applications<br />

Liquid Chromatography Cartridge Column Applications<br />

Parabens in Hand Cream<br />

Peak Identification<br />

1. Methylparaben<br />

2. Ethylparaben<br />

3. Propylparaben<br />

4. Butylparaben<br />

CHROMATOGRAPHIC CONDITIONS<br />

Column: Pecosphere 3 x 3CR C18 (33 x 4.6 mm)<br />

Detection: UV at 254 nm<br />

Mobile Phase: 50/50 v/v Methanol/H 2 0<br />

Flow Rate: 3 mL/min.<br />

Inj. Volume: 10 μL<br />

Part No. 02580195<br />

Phenothiazines<br />

Peak Identification<br />

1. Mesoridazine<br />

2. Promazine<br />

3. Thiothixene<br />

4. Chlorpromazine<br />

5. Trifluoperazine<br />

6. Thioridazine<br />

1<br />

3<br />

0 30<br />

Seconds<br />

0 10<br />

MINUTES<br />

Handcream<br />

Standards<br />

1<br />

2<br />

3<br />

4<br />

0 30<br />

Seconds<br />

CHROMATOGRAPHIC CONDITIONS<br />

Column: Brownlee RP-8 Spheri-5 (220 x 2.1 mm)<br />

Detection: UV at 200 nm<br />

Mobile Phase: A: 0.08% Diethylamine 0.08% Phosphoric Acid 90%<br />

Acetonitrile<br />

B: 0.08% Diethylamine 0.09% Phosphoric Acid pH 2.3<br />

Gradient: 5% A for 2 min.; 5% – 100% A in 15 min.; 100% A for 5 min.<br />

Flow Rate: 0.5 mL/min.<br />

Temperature: 50 °C<br />

Part No. 07110006<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

Intensity, cps<br />

Prednisone in Tablet Preparations<br />

Peak Identification<br />

1. Acetanilide<br />

2. Prednisone<br />

2.5 mg<br />

Deltasone<br />

Tablet<br />

CHROMATOGRAPHIC CONDITIONS<br />

Column: Pecosphere 3 x 8 C18 (83 x 4.6 mm i.d.)<br />

Detection: UV at 254 nm<br />

Mobile Phase: 50/50 v/v methanol/water<br />

Flow Rate: 2 mL/min.<br />

Inj. Volume:10 μL<br />

Part No. 02580166<br />

1<br />

2<br />

Standards<br />

45 SECONDS 45 SECONDS<br />

The LC/MS Identification and Quantitation of<br />

Quinolone Antibiotic Degradation Products<br />

Photolyte 2 MS<br />

308.2<br />

290.2<br />

300 m/z, amu<br />

Lomefloxacin MS<br />

352.2<br />

308.2<br />

300 m/z, amu<br />

1 2 3 4 5 6 7<br />

Time, Minutes<br />

CHROMATOGRAPHIC CONDITIONS<br />

Column: Reduced Activity C18 (33 x 4.6 mm, 3-μm)<br />

Detection: LC/MS with IonSpray (pneumatically assisted electrospray)<br />

Mobile Phase: Solvent A: 95% water, 0.1% formic acid, 5% MeOH<br />

Solvent B: 95% MeOH, 0.1% formic acid, 5% water<br />

0-12% B (convex, program 4) in 5 min., hold 5 min.<br />

Flow Rate: 1 mL/min. – split 65 mL/min. to MS, the rest to UV detector<br />

Sample: A partially degraded sample of Lomefloxacin (25 μg/mL) after<br />

irradiation for 10 min. Note photolyte 2 is only at ~0.5% level.<br />

Part No. 02580195<br />

Extracted Ion Chromatogram<br />

m/z = 332<br />

4.51<br />

m/z = 294<br />

4.66<br />

m/z = 308<br />

5.22<br />

4 5 6 7<br />

Total Ion Chromatogram<br />

Photolyte 3<br />

Photolyte 1<br />

Photolyte 2<br />

4.56<br />

4.66 5.22<br />

Lomefloxacin<br />

1<br />

2<br />

m/z = 352<br />

m/z = 308<br />

284


Cartridge Columns<br />

Brownlee CHOICE Columns for LC/MS<br />

Columns for LC/MS<br />

The matrix below illustrates the wide variety of column<br />

dimensions for the different chromatographic needs. Shorter<br />

length columns allow for faster separations. Smaller internal<br />

diameters (i.d.) offer higher sensitivity for smaller sample<br />

concentration. A longer column will be better suited to<br />

more complicated mixtures or where resolution may be<br />

difficult. If sample size is a concern; use a column with a<br />

smaller internal diameter; 2.1 or 3.2 mm, since this will<br />

provide greater sensitivity.<br />

There are four levels of efficiency/capacity to choose from:<br />

Type of Spectrometer User Needs Column Recommendation<br />

Triple or Single quad Moderate efficiency 20 x 3.2, 3 μm<br />

Low capacity<br />

High throughput<br />

Single quad Better efficiency 30 x 2.1, 3 μm<br />

Medium capacity 30 x 4.6, 5 μm<br />

Triple quad Best efficiency 50 x 3.2, 3 μm<br />

Medium capacity 50 x 3.2, 5 μm<br />

Triple quad High efficiency 50 x 4.6, 5 μm<br />

High capacity<br />

CHOICE Columns<br />

The CHOICE columns provide the speed and efficiency<br />

appropriate for LC/MS. Each column’s separation<br />

requirements vary depending on the system, sample,<br />

and mass spectrometer.<br />

PFPP for Separating Basic Drugs for LC/MS<br />

Penta Fluoro Phenyl Propyl (PFPP) phase is ideal for basic<br />

drug separation prior to mass spectrometry. This bonded<br />

phase has been shown to efficiently separate basic drugs<br />

in a 90% Acetonitrile/water mobile phase, eliminating the<br />

interference of ion-pairing reagents and ion-suppressing<br />

agents normally used for these separations on C18. 1, 2<br />

References:<br />

1<br />

S.R. Needham, et.al. Rapid Commun. in Mass Spectrom.,<br />

13, 2231-2236 (1999)<br />

2<br />

S.R. Needham, et.al. J. Chromatogr, A 869 (2000) 159-170<br />

Particle Pore Surface % End<br />

Description Size Diameter Area (M 2 /G) Carbon Cap<br />

CHOICE C18, 3 μ 3 μm 100 Å 350 12% Yes<br />

CHOICE C8, 3 μ 3 μm 100 Å 350 7% Yes<br />

CHOICE C18, 5 μ 5 μm 100 Å 350 12% Yes<br />

CHOICE PFPP, 5 μ 5 μm 100 Å 320 5% Yes<br />

30x2.1 mm i.d.** 30x4.6 mm i.d.** 50x3.2 mm i.d.* 50x4.6 mm i.d.*<br />

1 per package 1 per package 1 per package 1 per package<br />

Description Part No. Each (€) Part No. Each (€) Part No. Each (€) Part No. Each (€)<br />

CHOICE C18, 3 μm N2580003 421<br />

CHOICE C8, 3 μm N2580012 408 N2580013 421<br />

CHOICE C18, 5 μm N2580020 408 N2580022 421 N2580021 421<br />

CHOICE PFPP, 5 μm N2580042 408<br />

* Requires Holder (N2580030)<br />

** Requires Holder (07150013)<br />

Note: See page 293 for additional MPLC holders.<br />

Specifications<br />

Cartridge Columns Liquid Chromatography<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

285


Cartridge Columns<br />

Brownlee MPLC Columns<br />

Ion Exchange<br />

Note: For additional Ion Exchange Column lengths, please see page 287.<br />

30 mm x 4.6 mm i.d.* 30 mm x 2.1 mm i.d.* 100 mm x 4.6 mm i.d.**<br />

2 per package 2 per package 1 per package<br />

Description Part No. Each (€) Part No. Each (€) Part No. Each (€)<br />

Liquid Chromatography Cartridge Columns<br />

AX-300, Aquapore ® 07110073 381 07110074 318 07110075 509<br />

7 μm, 300 Å, weak anion<br />

Polypore ® CA 07110091 381 07110093 625<br />

10 μm, polymeric, calcium form<br />

Polypore H 07110085 611 07110087 1185<br />

10 μm, polymeric, hydrogen form<br />

Polar Phase<br />

Note: For additional Polar Phase Column lengths, please see page 287.<br />

Amino, Spheri-5 ® 07110037 165 07110039 292<br />

Aminopropyl, 5 μm, 80 Å<br />

Cyano, Spheri-5 07110043 165 07110045 292<br />

Cyanopropyl, 5 μm, 80 Å<br />

Silica, Spheri-5 07110031 165 07110032 126 07110033 381<br />

5 μm, 80 Å<br />

Silica, Spheri-10 07110145 152<br />

10 μm, 80 Å<br />

Reversed Phase<br />

Note: For additional Reversed Phase Column lengths, please see page 287.<br />

BU-300, Aquapore Butyl C-4, 07110061 190 07110062 165<br />

7 μm, 300 Å<br />

Cyano, Spheri-5 07110043 165 07110045 292<br />

Cyanopropyl, 5 μm, 80 Å<br />

OD-300, Aquapore ODS 07110235 165 07110234 165 07110232 292<br />

C-18, 7 μm, 300 Å<br />

ODS, Spheri-5 07110019 165 07110020 114 07110021 356<br />

C-18, polyfunctional, 5 μm, 80 Å,<br />

Phenyl, Spheri-5 07110025 190 07110027 332<br />

Phenyl, 5 μm, 80 Å<br />

RP-8, Spheri-5 07110001 165 07110002 126 07110003 356<br />

C-8, monofunctional, 5 μm, 80 Å<br />

RP-8, Spheri-10 07110121 152 07110123 254<br />

C-8, monofunctional, 10 μm, 80 Å<br />

RP-18, Spheri-5 07110013 165 07110014 165 07110015 228<br />

C-18, monofunctional, 5 μm, 80 Å<br />

RP-18, Spheri-10 07110115 165 07110117 420<br />

C-18, monofunctional, 10 μm, 80 Å<br />

RP-300, Aquapore Octyl C-8, 07110055 190 07110056 228 07110057 356<br />

7 μm, 300 Å<br />

* Requires Holder (07150013)<br />

** Requires Holder (07150014)<br />

286


Cartridge Columns<br />

Brownlee MPLC Columns<br />

Ion Exchange<br />

Note: For additional Ion Exchange Column lengths, please see page 286.<br />

100 mm x 2.1 mm i.d.** 220 mm x 4.6 mm i.d.*** 220 mm x 2.1 mm i.d.***<br />

1 per package 1 per package 1 per package<br />

Description Part No. Each (€) Part No. Each (€) Part No. Each (€)<br />

AX-300, Aquapore ® 07110077 802<br />

7 μm, 300 Å, weak anion<br />

Polypore ® CA 07110095 955<br />

10 μm, polymeric, calcium form<br />

Polypore H 07110089 1529<br />

10 μm, polymeric, hydrogen form<br />

Polar Phase<br />

Note: For additional Polar Phase Column lengths, please see page 286.<br />

Amino, Spheri-5 ® 07110041 381<br />

Aminopropyl, 5 μm, 80 Å<br />

Cyano, Spheri-5 07110047 483<br />

Cyanopropyl, 5 μm, 80 Å<br />

Silica, Spheri-5 07110035 483<br />

5 μm, 80 Å<br />

Silica, Spheri-10<br />

10 μm, 80 Å<br />

Reversed Phase<br />

Note: For additional Reversed Phase Column lengths, please see page 286.<br />

BU-300, Aquapore Butyl C-4, 07110064 356<br />

7 μm, 300 Å<br />

Cyano, Spheri-5 07110047 483<br />

Cyanopropyl, 5 μm, 80 Å<br />

OD-300, Aquapore ODS 07110233 318 07110231 356 07110236 356<br />

C-18, 7 μm, 300 Å<br />

ODS, Spheri-5 07110022 254 07110023 509 07110024 420<br />

C-18, polyfunctional, 5 μm, 80 Å,<br />

Phenyl, Spheri-5 07110029 547<br />

Phenyl, 5 μm, 80 Å<br />

RP-8, Spheri-5 07110004 318 07110005 547 07110006 381<br />

C-8, monofunctional, 5 μm, 80 Å<br />

RP-8, Spheri-10<br />

C-8, monofunctional, 10 μm, 80 Å<br />

RP-18, Spheri-5 07110016 292 07110017 547 07110018 318<br />

C-18, monofunctional, 5 μm, 80 Å<br />

RP-18, Spheri-10 07110119 381<br />

C-18, monofunctional, 10 μm, 80 Å<br />

RP-300, Aquapore Octyl C-8, 07110058 292 07110059 611 07110060 381<br />

7 μm, 300 Å<br />

** Requires Holder (07150014)<br />

*** Requires Holder (07150015)<br />

Cartridge Columns Liquid Chromatography<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

287


Cartridge Columns<br />

Brownlee Peco Fast LC Columns<br />

Liquid Chromatography Cartridge Columns<br />

Fast HPLC with 3x3 TM Peco Columns<br />

PerkinElmer pioneered the development of Fast HPLC and<br />

introduced the popular 3x3 Columns (33 x 4.6 mm) in the<br />

80s. The 3x3 Column is capable of very rapid analysis, as<br />

short as one to two minutes. These columns are available in<br />

economical packs of five. The 83 mm long 3x8 Column with<br />

>10,000 plates can separate many complex mixtures in less<br />

than 10 minutes.<br />

PerkinElmer’s Peco cartridges (including Fast HPLC) are<br />

available with MPLC ® holders. Three cartridge lengths<br />

(33, 83, and 150 mm) are available in 4.6 mm i.d.<br />

Additionally, the Peco cartridges are still compatible with<br />

the “old-style” Peco cartridge holders (wrench-tightened).<br />

Three Peco silica-based supports are available.<br />

Peco MPLC holders (83 and 33 mm).<br />

Pecosphere TM is a small-pore, extremely rugged<br />

(80 Å, 3, 5, and 10 μm, C18 or silica) sorbent for<br />

HPLC of small molecules.<br />

Peco HCODS is a wide-pore (300 Å, 5 μm, polyfunctional<br />

C18) sorbent for separation of proteins and peptides.<br />

Reduced Activity is a small-pore, base-deactivated<br />

(100 Å, 3, and 5 μm, C8 or C18) sorbent developed<br />

for HPLC of basic analytes and pharmaceuticals. The<br />

proprietary bonding chemistry increases its resistance<br />

to acidic mobile phase.<br />

SCAVENGER COLUMNS are small precolumns<br />

(33 x 4.6 mm i.d.) packed with 10 μm, C18 or silica<br />

materials. The scavenger is placed before the injector<br />

to protect the analytical column from mobile phase<br />

contaminant's. Its use is mandatory for Fast HPLC to<br />

prolong column life. It is available as a pack of five<br />

and requires the Peco MPLC holder.<br />

Specifications<br />

UV ABSORBANCE<br />

Analysis of Water-Soluble Vitamins<br />

in Multivitamin Tablets<br />

295 nm<br />

Standards<br />

275 nm<br />

1<br />

2<br />

3<br />

Multivitamin Capsule<br />

1<br />

3<br />

4<br />

4<br />

Centrum TM Tablet<br />

1<br />

3<br />

4<br />

CHROMATOGRAPHIC CONDITIONS<br />

Column: Reduced-activity 3 μm C8 column<br />

(83 mm x 4.6 mm i.d.)<br />

Found (mg)<br />

1. 176.00<br />

3. 26.00<br />

4. 2.23<br />

5. 11.30<br />

6. 1.06<br />

7. 5.38<br />

Found (mg)<br />

1. 74.00<br />

3. 18.50<br />

4. 2.51<br />

5. 1.45<br />

6. 0.42<br />

7. 1.62<br />

Detection: UV Absorbance at 275 nm<br />

Mobile Phase: 15% Methanol, 85% [10 mM Hexanesulfonate,<br />

1% Acetic Acid, 0.13% Triethylamine in Water]<br />

Flow Rate: 1.5 mL/min. at 35 °C<br />

Sample: 5 μL of Vitamin Tablet Extracts<br />

5<br />

5<br />

5<br />

0.0 5.0 10.0<br />

TIME (MIN.)<br />

Part No. 02580192<br />

1. Vitamin C<br />

2. Niacin<br />

3. Niacinamide<br />

4. Pyridoxine<br />

Particle Pore Surface % End<br />

Product Functionality Size μm Diameter Å Area (M 2 /G) Carbon Cap<br />

Pecosphere 3 C18 C18, monofunctional 3 80 170 11 Yes<br />

Pecosphere 5 C18 C18, monofunctional 5 80 170 11 Yes<br />

Reduced Activity 3 C18 C18, monofunctional 3 80 200 12 Yes<br />

Reduced Activity 3 C8 C8, monofunctional 3 80 200 5 Yes<br />

Reduced Activity 5 C18 C18, monofunctional 5 80 200 12 Yes<br />

Reduced Activity 5 C8 C8, monofunctional 5 80 200 5 Yes<br />

Peco HCODS C18, polyfunctional 5 300 90 9 No<br />

C18 Scavenger C18, monofunctional 10 80 170 11 Yes<br />

6<br />

6<br />

6<br />

7<br />

7<br />

7<br />

5. Thiamine<br />

6. Folic Acid<br />

7. Riboflavin<br />

288


Cartridge Columns<br />

Brownlee Peco Fast LC Columns<br />

Normal Phase<br />

33 x 4.6 mm i.d.* 83 x 4.6 mm i.d.** 150 x 4.6 mm i.d.***<br />

5 per package 1 per package 1 per package<br />

(requires holder 07150028) (requires holder 07150029) (requires holder 07150030)<br />

Description Part No. Each (€) Part No. Each (€) Part No. Each (€)<br />

Pecosphere 3 Silica 02580167 281<br />

Reversed Phase<br />

Monofunctional; Pore Diameter 80 Å<br />

Pecosphere 3 C18, 3 μm 02580164 555 02580166 287<br />

Pecosphere 5 C18, 5 μm 02580169 332<br />

Pecosphere 3CR C8, Base Deactivated, 3 μm 02580191 619 02580192 274<br />

Pecosphere 3CR C18, Base Deactivated, 3 μm 02580195 778 02580194 274<br />

Reduced Activity 5 C18, 5 μm N9303396 357<br />

Reduced Activity 5 C8, 5 μm 02580168 299<br />

Peco HCODS C18, Polyfunctional, 5 μm, 300 Å 02580213 242<br />

Scavenger Columns<br />

Silica Scavenger, 10 μm 02580203 510<br />

C18 Scavenger, Monofunctional, 10 μm, 80 Å 02580202 593<br />

Van Deemter’s Curves<br />

HETP (μm)<br />

60<br />

40<br />

20<br />

5 μm<br />

0<br />

0 2 4 6 8<br />

FLOW RATE (mL/min)<br />

10 μm<br />

3 μm<br />

Van Deemter’s curves showing column plate height vs. flow rate for 3,<br />

5, and 10 μm particle columns. The 3 μm particle is preferred for Fast<br />

LC because of its superior performance and higher optimum flow rate.<br />

Analysis of an Analgesic<br />

Tablet Using Fast LC<br />

Peak Identification<br />

1. Acetaminophen<br />

2. Caffeine<br />

3. Salicylamide<br />

4. Acetylsalicylic Acid<br />

0 1 2<br />

TIME (MIN.)<br />

CHROMATOGRAPHIC CONDITIONS<br />

Column: Pecosphere 3x3 C18 (33 x 4.6 mm)<br />

Detection: UV at 240 nm<br />

Mobile Phase: 15% CH 3 CN in H 2 0<br />

Flow Rate: 2.0 mL/min.<br />

Sample: 1 μL of the tablet extract<br />

Part No. 02580164<br />

1<br />

2<br />

3<br />

4<br />

Cartridge Columns Liquid Chromatography<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

289


Cartridge Columns<br />

Brownlee Preparative and VeloSep Columns<br />

Liquid Chromatography Cartridge Columns<br />

Brownlee Preparative Columns<br />

Preparative columns are 10 mm i.d. cartridges, packed with<br />

Aquapore ® 20 μm, 300 Å sorbents.<br />

Easy scale-up from the Aquapore analytical<br />

columns using similar bonded phase<br />

Available in 30, 100, and 250 mm cartridges<br />

The unique 100 and 250 mm cartridge design<br />

incorporates a moveable inlet plug and filter which<br />

compensates for changes in bed volume with use<br />

Typical sample capacity of the 250 mm cartridge<br />

is 50 mg to 1 g of material (depending on resolution and<br />

purity requirements). The typical flow rate is 4-10 mL/min.<br />

Save time with high-pressure<br />

preparative runs up to 3000 psi<br />

Achieve high performance with<br />

the 20 μm, 300 Å sorbents<br />

optimized for bioseparations<br />

Specifications<br />

Pore Diameter: 300 Å - Surface Area: 100 M 2 /G - End Cap: Yes<br />

Product Functionality % Carbon<br />

Aquapore Octyl Octyl (C8) 5<br />

Aquapore ODS Octadecyl (C18) 10<br />

Note: The Aquapore Preparative Sorbents are spherical 20 μm<br />

silica-based sorbents.<br />

Preparative Columns<br />

20 μm, 300 Å, 10 mm i.d.<br />

Description Part No. Each (€) Part No. Each (€)<br />

Aquapore Octyl 07110165* 700 07110166** 891<br />

Aquapore ODS 07110114* 675 07110163** 1121<br />

* 100 mm Cartridge (Requires holder 07150005)<br />

** 250 mm Cartridge (Requires holder 07150006)<br />

Brownlee VeloSep Columns<br />

VeloSep ® columns are 3.2 mm i.d. cartridges packed with<br />

3 μm reversed-phase support for high throughput analysis<br />

and reduced solvent consumption.<br />

Improve sensitivity and speed while cutting<br />

solvent consumption by half<br />

Packed with 3 μm C8 or C18 sorbents<br />

Available in 40 or 100 mm lengths<br />

Specifications<br />

Prep-10 Cartridges<br />

Pore Diameter: 100 Å - Surface Area: 170 M 2 /G - End Cap: Yes<br />

Product Functionality % Carbon<br />

RP-8, VeloSep Octyl (C8) 7<br />

RP-18, VeloSep Octadecyl (C18) 14<br />

VeloSep Columns<br />

3 μm, C18, 100 Å, 3.2 mm i.d.<br />

Description Part No. Each (€) Part No. Each (€)<br />

RP-8, VeloSep 07110189* 165 07110190** 318<br />

RP-18, VeloSep 07110191* 152 07110192** 254<br />

* 40 mm Cartridge, (pkg. 2), (Requires holder 07150013)<br />

** 100 mm Cartridge (Requires holder 07150014)<br />

Analysis of Penicillins<br />

VeloSep RP-18, 3 μm, 100 x 3.2 mm<br />

Purification of Synthetic Trityl-On Oligonucleotides<br />

Aquapore Octyl, 20 μm 250 x 10 mm<br />

ABSORBANCE mAU<br />

CHROMATOGRAPHIC CONDITIONS<br />

Conditions: Solvent A: 10 mM Sodium Phosphate pH 6.5<br />

Solvent B: 50% Isopropyl Alcohol in Water<br />

Gradient: 5-50% B in 10 min.<br />

Flow Rate: 0.5 mL/min.<br />

Temperature: 5 °C, 230 nm<br />

Part No. 07110192<br />

600<br />

500<br />

400<br />

300<br />

200<br />

100<br />

ABSORBANCE<br />

0<br />

0 5 10<br />

TIME (MIN.)<br />

2.859<br />

2.859<br />

2.029<br />

Amoxicillin<br />

Ampicillin<br />

4.018<br />

5.250<br />

5.250<br />

6.770<br />

7.184<br />

0.333<br />

8.926<br />

9.643<br />

10.117<br />

0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34<br />

TIME (MIN.)<br />

CHROMATOGRAPHIC CONDITIONS<br />

Conditions: Buffer A: 100 mM Triethylammonium Acetate pH 7.6<br />

Buffer B: 80% Acetonitrile in Buffer A<br />

Gradient: 10-45% B in 35 min.<br />

Sample: 0.25 μ Mole DNA material<br />

Flow Rate: 5.0 mL/min. Ambient. 260 nm<br />

Part No. 07110166<br />

Cloxicillin contaminant<br />

Penicillin G<br />

20.218<br />

23.474<br />

Piperacillin<br />

Cloxicillin<br />

26.736<br />

290


Cartridge Columns<br />

Brownlee Validated MPLC Columns<br />

Brownlee Validated Columns<br />

Brownlee Validated Sorbent<br />

The Brownlee Validated Sorbent is derived from a neutral<br />

“Type B” silica with inherent low silanophilic activity. Each<br />

sorbent lot is tested to meet stringent specifications for the<br />

separation of basic, neutral, and acidic test probes. Column<br />

lifetime studies and additional selectivity evaluations using<br />

real samples are also conducted. A high-temperature bonding<br />

technique is coupled with an exhaustive end-capping<br />

procedure to ensure maximum coverage of the silica surface.<br />

A proprietary treatment step is used to further eliminate<br />

any trace residual metals in the silica that create active<br />

adsorptive sites. The result is a highly deactivated column<br />

which yields excellent peak shape for difficult basic analytes,<br />

pharmaceuticals, and small peptides.<br />

Important Features of Validated Columns<br />

Convenient cartridge design<br />

Guaranteed batch-to-batch reproducibility<br />

Test Chromatogram and Certification of Compliance shipped<br />

with each column (except for 30 mm and NewGuard ® )<br />

Packed with a 5 μm reduced activity monofunctional C18 sorbent<br />

Compatibility with acidic, neutral, and basic analytes<br />

Excellent column lifetime<br />

Available in 30, 100, 150, or 220 mm MPLC cartridges<br />

(2.1 mm and/or 4.6 mm i.d.)<br />

Select 100 mm cartridge for routine assays<br />

30 mm cartridge for screening or as a replaceable front end<br />

Use 2.1 mm i.d. cartridges to reduce solvent consumption<br />

Lot history tracking system<br />

Specifications<br />

Validated MPLC Columns<br />

Validated C18 (100 x 4.6 mm i.d.) 34% MeOH,<br />

65% water, 1% HOAc, 1 mL/min., 1650 psi,<br />

30 °C 10 μL of degraded chlorthalidone at 1 μg/μL<br />

ABSORBANCE mAU<br />

200<br />

180<br />

160<br />

140<br />

120<br />

100<br />

80<br />

60<br />

40<br />

20<br />

Pore Surface % End<br />

Product Functionality Diameter Area (M 2 /G) Carbon Cap<br />

Validated (5 μm) C18 monofunctional 100 Å 350 ± 10% 18% Yes<br />

Description Part No. Each (€)<br />

Validated C18, 220 x 4.6 mm (requires 220 mm holder 07150015) 00402243 514<br />

Validated C18, 150 x 4.6 mm (requires 150 mm holder 07150030) 00403058 636<br />

Validated C18, 100 x 4.6 mm (requires 100 mm holder 07150014) 00402241 445<br />

Validated C18,100 x 2.1 mm (requires 100 mm holder 07150014) 00402240 318<br />

Validated C18, 30 x 4.6 mm (requires 30 mm holder 07150013) 00402239 292<br />

Validated C18, NewGuard, 15 x 3.2 mm 00402237 165<br />

(requires NewGuard holder 07150001)<br />

100 mm NewGuard System Holder 07150016 318<br />

(For direct coupling of NewGuard and 100 mm cartridge)<br />

Union (For direct coupling of two cartridges) 07150018 152<br />

Note: See page 293 for additional MPLC holders.<br />

Impurity<br />

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15<br />

TIME (MIN.)<br />

Comparative test results of columns packed with three different silica<br />

lots for a USP assay of chlorthalidone. The chromatogram of a degraded<br />

bulk sample (1 mg/mL) shows the presence of an unidentified impurity,<br />

chlorthalidone, its hydrolysis product, 4'-chloro-3'-sulfamoyl-2-<br />

benzophenone carboxylic acid (CCA) and a degradation product,<br />

2-chloro-5- (1-methoxy-3-oxo-1-isoindoliny)-benzenesulfonamide (CBSA).<br />

Part No. 00402241<br />

Validated C18 (100 x 4.6 mm),<br />

75/25 MeOH/Water 1 mL/min.,<br />

30 °C, 230 nm detection<br />

Pyridine<br />

Uracil<br />

Chlorthalidone<br />

CCA<br />

Propyl<br />

Paraben<br />

0 TIME (MIN.) 4<br />

CBSA<br />

N, N-dimethylaniline<br />

Toluene<br />

Silica Lot 1<br />

Lot 2<br />

Lot 3<br />

Performance of Validated Column with basic,<br />

acidic, and neutral test probes.<br />

Part No. 00402241<br />

Cartridge Columns Liquid Chromatography<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

291


Cartridge Columns<br />

Guard Cartridge Columns and Accessories<br />

NewGuard Columns<br />

Standards Solutions<br />

Liquid Chromatography Cartridge Columns<br />

NewGuard cartridges are small guard cartridges (15 mm x 3.2<br />

mm i.d.) packed with 5 or 7 μm sorbents. NewGuard<br />

cartridges prolong column life by eliminating particulates,<br />

contaminant's, and strongly bound sample components.<br />

They act as replaceable, disposable heads of your analytical<br />

columns. There is negligible loss of efficiency and little effect<br />

on retention or resolution. NewGuards are available<br />

in a convenient 3-pack and can be coupled directly to any<br />

MPLC cartridge with a union (07150018).<br />

Prolong column life by 2 to 5 times<br />

Protect your column from particulates and strongly<br />

bound sample components<br />

Optimized dimensions to prevent loss of resolution<br />

Easy coupling to MPLC cartridges or conventional columns<br />

Finger-tight seal to 7000 psi using NewGuard holders<br />

Can be used for sample preconcentration<br />

(connected to sample injection loop)<br />

15 mm cartridge*, 3.2 mm i.d., 3 per pkg.<br />

Description Part No. Each (€)<br />

Amino, Aquapore ® Amino, 7 μm spherical 07110098 126<br />

Anion, Aquapore Anion, 7 μm spherical 07110102 152<br />

Cyano, Aquapore Cyano, 7 μm spherical 07110100 126<br />

Diol, Aquapore Diol, 7 μm spherical 07110105 153<br />

Phenyl, Aquapore Phenyl, 7 μm spherical 07110096 126<br />

RP-2, Aquapore Dimethyl, 7 μm spherical 07110086 126<br />

RP-4, Aquapore Butyl, 7 μm spherical 07110088 126<br />

RP-8, Aquapore Octyl, 7 μm spherical 07110090 126<br />

RP-18, Aquapore ODS, 7 μm spherical 07110092 126<br />

Silica, Aquapore Silica, 7 μm spherical 07110106 101<br />

Validated ® , C18, 5 μm spherical 00402237 165<br />

* Requires holder (07150001)<br />

Note: Actual bed length of NewGuard is about 13 mm<br />

Replacement Seals for MPLC and Prep-10 Holders<br />

Test Mix<br />

Description Part No. Each (€)<br />

Universal test mix for reversed-phase (5 mL/pkg.) 00890893 43<br />

Standards<br />

Description Part No. Each (€)<br />

HPLC SV Calibration Mix #5/610 PAH 00891542 114<br />

HPLC 610 Calibration Mix A 00891543 59<br />

HPLC 610 Calibration Mix B 00891544 59<br />

NewGuard cartridges directly coupled to a 220 mm MPLC<br />

cartridge and connected externally to a 250 mm conventional column.<br />

View of the NewGuard holder<br />

and a NewGuard 3/pack.<br />

Item Description Part No. Each (€)<br />

Prep-10 Inlet Seal One each (Prep-10 Seal Replacement Kit tools required) 07150012 37<br />

Prep-10 Outlet Seal One each (Prep-10 Seal Replacement Kit tools required) 07150026 24<br />

Seals for MPLC Holders Two 7000 psi seals (Seal Replacement Kit tools required) 07150024 37<br />

Seal Replacement Kit for MPLC Holders Tools and two 7000 psi seals 07150023 126<br />

292


Cartridge Columns<br />

Holders and Accessories for Cartridge Columns<br />

Product MPLC/Peco Family<br />

TM Holders<br />

The patented MPLC cartridge system ensures leak-free operation up to 7000 psi, with only finger-tightening. The<br />

high-pressure seal in each end assembly actually seals tighter as pressure increases. No wrenches are required, and<br />

there is no need to disconnect any tubing to your LC system when changing a cartridge. Each MPLC cartridge can<br />

be directly coupled to another using a union.<br />

Name Description Part No. Each (€)<br />

Universal Holder Kit Includes 100 and 220 mm holder bodies, 07150025 483<br />

2 end assemblies, 1 union, 1 NewGuard end assembly.<br />

NewGuard ® Holder Holds a single NewGuard cartridge or a single 20 mm 07150001 190<br />

CHOICE TM cartridge.<br />

30 mm Holder Holds a single MPLC and CHOICE 30 mm cartridge. 07150013 190<br />

33 mm Peco Holder Holds 33 mm Fast LC Peco cartridge only. 07150028 228<br />

50 mm Holder Holds a single 50 mm CHOICE cartridge only. N2580030 244<br />

83 mm Peco Holder Holds 83 mm Fast LC Peco cartridge only. 07150029 292<br />

100 mm Holder Holds a single MPLC 100 mm cartridge. 07150014 190<br />

150 mm Holder Holds a single MPLC 150 mm cartridge. 07150030 165<br />

220 mm Holder Holds a single MPLC 220 mm cartridge. 07150015 190<br />

250 mm Holder Holds a single MPLC 250 mm cartridge. 07150031 318<br />

100 mm NewGuard Holder for a NewGuard and a 100 mm coupled cartridge. 07150016 318<br />

System Holder<br />

220 mm NewGuard Holder for a NewGuard 07150017 318<br />

System Holder<br />

and a 220 mm coupled cartridge.<br />

130 mm MPLC Holder for a 30 and 100 mm coupled cartridge. 07150032 292<br />

System Holder<br />

Union For direct coupling of 2 cartridge holders. 07150018 152<br />

(Two holder bodies and 2 end assemblies also required.)<br />

NewGuard Upgrades a 30 mm holder to a NewGuard holder. 07150002 126<br />

End Assembly<br />

End Assembly Holder component. 07150019 75<br />

30 mm Holder Body Holder component. 07150020 37<br />

100 mm Holder Body Holder component. 07150021 45<br />

220 mm Holder Body Holder component. 07150022 63<br />

Prep-10 Cartridge Holders<br />

100 mm Prep-10 Holder Holds a single 100 mm Prep-10 cartridge. 07150005 356<br />

250 mm Prep-10 Holder Holds a single 250 mm Prep-10 cartridge. 07150006 445<br />

Cartridge Columns Liquid Chromatography<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

293


Conventional Columns<br />

Conventional Columns<br />

Brownlee Conventional Columns<br />

Conventional Brownlee Columns (non-cartridge) use standard<br />

compression end fittings compatible with all HPLC instrumentation.<br />

These columns do not require MPLC holders.<br />

■ End fittings compatible with HPLC systems from any vendor<br />

■ Use with NewGuard system (line connection) for even longer column life<br />

■ Each column is individually tested<br />

Conventional columns do not require MPLC holders.<br />

Brownlee Microbore HPLC Columns<br />

Microbore columns (1.0 mm i.d.) are ideal for the analysis of samples<br />

of limited availability (e.g., micropurification of picomole levels of<br />

proteins/peptides). Reducing the column diameter from the standard<br />

4.6 mm to 1.0 mm increases the mass sensitivity by 20 times. Sample<br />

components can be collected in small elution volumes (1-50 μL) for<br />

further sequence or mass analysis. Microbore offers major benefits in<br />

pharmacokinetic assays and LC/MS applications. The typical flow<br />

rate range is 10-100 μL/min., therefore specialized HPLC systems<br />

may be required for optimum column performance.<br />

■ Increase sensitivity and decrease solvent consumption by a factor of 20<br />

(compared with 4.6 mm i.d.)<br />

■ Reduce sample size for pharmacokinetic assays<br />

■ Better compatibility with LC/MS interfaces<br />

■ Each column is individually tested<br />

250 mm, 100 mm Microbore Columns (1.0 mm i.d.)<br />

Modes of Separation<br />

Reversed-Phase Chromatography (RPC) is the most popular HPLC mode<br />

and is used in 60-80% of all applications. In RPC, hydrophobic groups<br />

(C18, C8, or C4) bonded to a silica support are used together with a<br />

mobile phase of water and organic solvent (e.g. methanol, acetonitrile).<br />

Polar Phase (Normal Phase) Chromatography (NPC) uses a polar stationary<br />

phase (unbonded silica, bonded amino or cyano group) together<br />

with a non-polar mobile phase (e.g., hexane). NPC is useful for<br />

functional group analysis, isomeric separations, purification of<br />

organics, and sample cleanup.<br />

Ion-Exchange Chromatography (IEC) utilizes bonded ionic groups to<br />

separate ionic analytes. Retention is based on the affinity of various<br />

analyte ions for the stationary phase and various mobile phase<br />

parameters (e.g., pH, ionic strength).<br />

Brownlee Analytical<br />

This is PerkinElmer’s all-purpose HPLC column line for<br />

conventional as well as high speed LC separations. The (110 Å)<br />

silica is equivalent to the Hypersil. Columns are available in 3<br />

or 5 μ and lengths ranging from 30-250 mm, in 2.1 and 4.6 i.d.<br />

The Brownlee Analytical family includes Amino, C18, C8,<br />

Cyano, Phenyl, Silica, and PAH phases.<br />

Brownlee Aquapore ®<br />

This is a wide-pore (300 Å, 7, and 20 μm), silica-based support<br />

suitable for the separation of large biopolymers<br />

Brownlee Bio<br />

This material is wide-pore silica (300 Å) that is excellent for peptide<br />

and protein separation. Columns are available in 5 μ and lengths<br />

ranging from 30-250 mm, in 2.1 and 4.6 i.d. in C8 and C18 phases.<br />

Brownlee CHOICE TM<br />

This line of columns is made of (60 Å) silica which results in large<br />

surface area, high carbon loads, and high retention compounds.<br />

Columns are available in 3 or 5 μm and lengths ranging from<br />

30-250 mm, in 2.1 and 4.6 i.d. The Brownlee Choice family<br />

includes the Basix, C18, Organic Acids, and PFP Propyl phases.<br />

Brownlee Spheri-5 ®<br />

This is a small-pore (80 Å, 5 μm), silica based sorbent for separating<br />

small molecules. Both monofunctional (comb-pre) and polyfunctional<br />

(polymerized loop-type) C8 and C18 sorbents available<br />

Brownlee Validated TM<br />

These columns are made on high-purity, Type B silica with<br />

inherent low silanophilic activity. It exhibits excellent peak shape<br />

for a wide range of compounds while also having a wide number<br />

of phases. The Brownlee Validated columns are the best choice<br />

for pharmaceutical applications that deal with a lot of basic or<br />

multi-functional compounds. Columns are available in 3 or 5 μ<br />

and lengths ranging from 30-250 mm, in 2.1 and 4.6 i.d., and<br />

include Amino, C18, C8, Carbamate, Cyano, IBD (intrinsically<br />

base-deactivated), PFP (pentafluorophenyl) and phenyl phases.<br />

Guard Columns and Cartridges<br />

To protect your column investment, we offer a complete line of<br />

guard columns in our direct connect guard cartridges. These can be<br />

attached to any column offered above. You can easily select the<br />

phase type to the appropriate guard column packing to ensure a<br />

correct silica match.<br />

294


Conventional Columns<br />

Conventional Columns Selection and Specification Guide<br />

Specifications<br />

Support Types<br />

Silica is the most common HPLC support. It is efficient and rugged, but has a limited pH range of 2-7. Polymer-based<br />

supports (polystyrene copolymer) offer a greater pH range of 1-14, but have lower pressure ratings and some limitations<br />

with organic solvents. Small-pore (80-100 Å) supports are used for small molecules, while wide-pore supports (300 Å)<br />

are better suited for proteins or other macro-molecules.<br />

Brownlee Pore % End<br />

Product Functionality Diameter (Å) Carbon Cap Applications Page No.<br />

Analytical Amino 110 2 No General purpose, excellent for carbohydrate analysis 308<br />

Analytical C18 110 13 Yes Superior general purpose for non-basic analytes 308<br />

Analytical C8 110 7 Yes Superior general purpose for non-basic analytes 308<br />

Analytical Cyano 110 4 Yes General purpose analysis Cyano used in either normal or reversed phase analytes 308<br />

Analytical Phenyl 110 6 Yes General purpose Phenyl for neutral analytes 308<br />

Analytical Silica 110 - - Ideal for polar analytes 308<br />

Analytical PAH 110 - Yes Maximum resolution of polynuclear aromatic hydrocarbons 308<br />

Bio C18 300 6 Yes Excellent for high molecular weight compounds and proteins 309<br />

Bio C8 300 - - Excellent for high molecular weight compounds and proteins 309<br />

CHOICE TM Basix 60 12 Yes Excellent for amine-containing compounds and basic pharmaceuticals. 310<br />

Ideal for LC/MS<br />

CHOICE C18 60 27 Yes Separates basic compounds showing good deactivation. 310<br />

Excellent for explosives or steroids<br />

CHOICE Organic Acids 60 - No Use for challenging organic acids 310<br />

CHOICE PFP Propyl 60 17 Yes Ideal for MS, ELSD, or NPD detection of nucleosides, nucleotides, 310<br />

purines, pyrimidines or halogenated compounds<br />

Validated TM Amino 100 2 No Ideal for carbohydrates 311<br />

Validated C1 100 5 - Exceptional stable C1 phase. Least retentive reversed phase hydrocarbon packing 311<br />

Validated C4 100 9 Yes High bonding coverage and base deactivation. Less retention than C18 or C8 311<br />

Validated Aqueous C18 100 15 No Excellent for highly water soluble or poorly organic soluble compounds 311<br />

such as water soluble vitamins and organic acids<br />

Validated C18 100 20 Yes Used for the detection of anilines, barbiturates, carbonyls, fat-soluble vitamins, 311<br />

fatty acids, glycerides, phthalates, PTH amino acids, steroids, other acids<br />

Validated C8 100 12 Yes Less hydrophobic retention than Brownlee Validated C18 311<br />

Validated Carbamate 100 - - Fast analysis of carbamates 312<br />

Validated Cyano 100 8 Yes Excellent for basic pharmaceuticals and steroids 312<br />

Validated IBD 100 12 No Unique separation for acids, bases, zwitterions, and other polar compounds 312<br />

Validated PFP 100 7 Yes Ideal for taxors and precursors or halogenated compounds, 312<br />

amines, esters or ketones<br />

Validated Phenyl 100 10 Yes Ideal for the separation of fatty acids, polynuclear aromatic hydrocarbons, 312<br />

purines and pyrimidines<br />

Conventional Columns Liquid Chromatography<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

295


Conventional Columns<br />

Conventional Column Applications<br />

Subject<br />

Biochemical<br />

Page No.<br />

Liquid Chromatography Conventional Columns<br />

Adenine, Adenosine, ATP, ADP, and AMP 297<br />

Aromatic Amino Acids 297<br />

Carboxylic Acids 297<br />

Nucleic Acid Bases 297<br />

Nucleotides, Nucleosides, and Nitrogenous Bases 298<br />

Purines/Pyrimidines 298<br />

Thymine, Thymidine, TTP, TDP, and TMP 298<br />

Dietary Supplements/Plant Extracts<br />

Allicin in Garlic Tablets 299<br />

Hyperforin in St. John’s Wort 299<br />

Phenethyl Glucosinsolate 299<br />

Vitamins (Fat Soluble) 299<br />

Environmental<br />

Aldehydes and Ketones (DNPH derivatives) 300<br />

Explosives by EPA Method 8330 C18 300<br />

Explosives by EPA Method 8330 Cyano 300<br />

Herbicides (Phenoxyacid Mix A) 301<br />

Herbicides (Phenoxyacid Mix B) 301<br />

Herbicides (Phenylureas) 302<br />

Pesticides 302<br />

Pesticides (Carbamates) 303<br />

Polynuclear Aromatic Hydrocarbons 303<br />

Food and Flavors<br />

Heat Level Assay for Habenero Nuggets 304<br />

Organic Acids in Grape Juice 304<br />

Organic Acids Standards 304<br />

Sugars 304<br />

Pharmaceutical<br />

Analgesic Acetaminophen and Narcotic Analgesics 305<br />

Analgesic Acetaminophen and Narcotic Analgesics 305<br />

Antiarrhythmic Atenolol 305<br />

Antiarrhythmic Calcium Channel Blockers 305<br />

Antibiotic Amoxicillin 306<br />

Antibiotic Sulfamethoxazole, Trimethoprim, and Napththoate 306<br />

Antidepressants (Tricyclic) 306<br />

Corticosteroids 306<br />

Corticosteroids – Standards 307<br />

Hormones B-Estridol, Norethindrone, and Ethynyl Estadiol 307<br />

Narcotic Analgesic Hydrocodone Bitartrate by USP 25 307<br />

296


Adenine, Adenosine, ATP, ADP, and AMP<br />

1<br />

2<br />

3<br />

0 2 4 6 8 10 12 14 16 18 20<br />

TIME (MIN.)<br />

CHROMATOGRAPHIC CONDITIONS<br />

Column: Brownlee Validated IBD<br />

Dimensions: 150 x 4.6 mm, 5 μm, 100 Å<br />

Detection: UV @ 260 nm<br />

Solvent: 20 mM Ammonium Acetate, pH 5.8<br />

Mobile Phase: 20 mM Ammonium Acetate, pH 5.8: Methanol (97.5:2.5)<br />

Flow Rate: 1.0 mL/min. @ 35 °C<br />

Injection: 20 μL<br />

Part No.<br />

4<br />

N9303582<br />

Aromatic Amino Acids<br />

Peak Identification<br />

1.<br />

2.<br />

3.<br />

5<br />

Conc.<br />

Peak Identification (μg/mL)<br />

1. ATP 258<br />

2. ADP 320<br />

3. AMP 274<br />

4. Adenine 84<br />

5. Adenosine 254<br />

CHROMATOGRAPHIC CONDITIONS<br />

Column: Brownlee Validated Aqueous C18<br />

Dimensions: 150 x 4.6 mm, 5 μm, 100 Å<br />

Detection: UV @ 254 nm<br />

Solvent: Mobile Phase A<br />

Mobile Phases: A: 50 mM Potassium Phosphate, pH 2.5<br />

B: Acetonitrile 5-20% B: 0-5 min. 20-5% B: 5-6 min.<br />

Hold at 5% B: 6-13 min.<br />

Flow Rate: 1.0 mL/min.<br />

Temperature: 30 °C<br />

Injection: 20 μL<br />

Part No.<br />

Tyrosine 0.2<br />

Phenylalanine 1.6<br />

Tryptophan 0.4<br />

N9303546<br />

Conc.<br />

(mg/mL)<br />

1<br />

0 2 4 6 8 10<br />

TIME (MIN.)<br />

2<br />

Conventional Column Applications<br />

3<br />

Carboxylic Acids<br />

Peak Identification<br />

1.<br />

2.<br />

3.<br />

4.<br />

5.<br />

6.<br />

Conc.<br />

(mg/mL)<br />

Malonic Acid 500<br />

Lactic Acid 500<br />

Acetic Acid 1000<br />

Citric Acid 1000<br />

Succinic Acid 2000<br />

Fumaric Acid 10<br />

Biochemical<br />

CHROMATOGRAPHIC CONDITIONS<br />

Column: Brownlee Validated Aqueous C18<br />

Dimensions: 150 x 4.6 mm, 5 μm, 100 Å<br />

Detection: UV @ 210 nm<br />

Solvent: Water<br />

Mobile Phase: 50 mM Potassium Phosphate, pH 2.5: Acetonitrile (99:1)<br />

Flow Rate: 1.5 mL/min.<br />

Temperature: 25 °C<br />

Injection: 10 μL<br />

Part No.<br />

N9303546<br />

Nucleic Acid Bases<br />

1<br />

0 1 2 3 4<br />

TIME (MIN.)<br />

CHROMATOGRAPHIC CONDITIONS<br />

Column: Brownlee Choice PFP Propyl<br />

Dimensions: 150 x 4.6 mm, 5 μm, 60 Å<br />

Conc.: 100 μg/mL each<br />

Detection: UV @ 260 nm<br />

Solvent: 20 mM Ammonium Acetate, pH 5.0 (Note: 1–3 drops of<br />

Ammonium Hydroxide added to keep Guanine in solution)<br />

Mobile Phase: 20 mM Ammonium Acetate, pH 5.0:Methanol (85:15, v/v)<br />

Flow Rate: 1.0 mL/min.<br />

Temperature: Ambient<br />

Injection: 1.0 μL<br />

Part No.<br />

1<br />

2 3<br />

N9303644<br />

4<br />

2<br />

3<br />

4<br />

5<br />

6<br />

Peak Identification<br />

1.<br />

2.<br />

3.<br />

4.<br />

5.<br />

Cytosine<br />

Uracil<br />

Guanine<br />

Thymine<br />

Adenine<br />

0 1 2 3 4 5 6 7 8 9<br />

TIME (MIN.)<br />

5<br />

Conventional Column Applications Liquid Chromatography<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

297


Conventional Column Applications<br />

Biochemical<br />

Liquid Chromatography Conventional Column Applications<br />

Nucleotides, Nucleosides, and Nitrogenous Bases<br />

Peak Identification<br />

1.<br />

2.<br />

3.<br />

4.<br />

5.<br />

6.<br />

7.<br />

8.<br />

9.<br />

10.<br />

11.<br />

Conc.<br />

(μg/mL)<br />

CDP 146<br />

CMP 113<br />

ATP 117<br />

ADP 145<br />

Cytidine 155<br />

TMP 157<br />

AMP 125<br />

Guanine 36<br />

Guanosine 103<br />

Adenine 38<br />

Adenosine 115<br />

CHROMATOGRAPHIC CONDITIONS<br />

Column: Brownlee Validated IBD<br />

Dimensions: 150 x 4.6 mm, 5 μm<br />

Detection: UV @ 260 nm<br />

Solvent: 20 mM Ammonium Acetate, pH 5.8<br />

Mobile Phase: 20 mM Ammonium Acetate, pH 5.8: Methanol (97.5:2.5)<br />

Flow Rate: 1.0 mL/min.<br />

Temperature: 35 °C<br />

Injection: 20 μL<br />

Part No.<br />

N9303582<br />

Purines/Pyrimidines<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

4 6 7<br />

2<br />

1 3<br />

5<br />

8<br />

9<br />

10<br />

11<br />

0 2 4 6 8 10 12 14 16 18<br />

TIME (MIN.)<br />

9 10<br />

0 5 10 15 20 25<br />

TIME (MIN.)<br />

11<br />

13 14<br />

12<br />

Thymine, Thymidine,<br />

TTP, TDP, and TMP<br />

Conc.<br />

Peak Identification (μg/mL)<br />

1. TTP 224<br />

2. TDP 152<br />

3. TMP 346<br />

4. Thymine 88<br />

5. Thymidine 318<br />

CHROMATOGRAPHIC CONDITIONS<br />

Column: Brownlee Validated IBD<br />

Dimensions: 150 x 4.6 mm, 5 μm, 100 Å<br />

Detection: UV @ 260 nm<br />

Solvent: 200 mM Ammonium Acetate, pH 5.8<br />

Mobile Phase: 20 mM Ammonium Acetate, pH 5.8: Methanol (97.5:2.5)<br />

Flow: 1.0 mL/min.<br />

Temperature: 35 °C<br />

Injection: 20 μL<br />

Part No.<br />

Peak Identification<br />

1.<br />

2.<br />

3.<br />

4.<br />

5.<br />

6.<br />

7.<br />

8.<br />

9.<br />

10.<br />

11.<br />

12.<br />

13.<br />

14.<br />

Cytosine<br />

5-Methylcytosine<br />

Uracil<br />

Uric Acid<br />

Hypoxanthine<br />

Xanthine<br />

Thymine<br />

Purine<br />

Theobromine<br />

Ethyluracil<br />

6-Methylpurine<br />

1, 7-Dimethylxanthine<br />

Theophylline<br />

Propyluracil<br />

CHROMATOGRAPHIC CONDITIONS<br />

Column: Brownlee Validated PFP<br />

Dimensions: 250 x 4.6 mm, 5 μm, 100 Å<br />

Conc.: 100 mg/mL each<br />

Detection: UV @ 260 nm<br />

Solvent: Mobile Phase<br />

Mobile Phase: 0.001% Formic Acid in Water: Methanol (50:50, v/v)<br />

Flow Rate: 1.0 mL/min.<br />

Temperature: Ambient<br />

Injection: 10 μL<br />

Part No.<br />

N9303582<br />

N9303600<br />

1<br />

2<br />

3<br />

4<br />

5<br />

0 2 4 6 8 10 12 14 16<br />

TIME (MIN.)<br />

298


Allicin in Garlic Tablets<br />

CHROMATOGRAPHIC CONDITIONS<br />

Column: Brownlee Analytical C18<br />

Dimensions: 150 x 4.6 mm, 5 μm, 110 Å<br />

Conc.: 1.2 mg/mL Garlic Tablet in Water<br />

Detection: UV @ 240 nm<br />

Solvent: Deionized Water<br />

Mobile Phase: Water:Methanol (50:50, v/v)<br />

Flow Rate: 0.8 mL/min.<br />

Temperature: 30 °C<br />

Injection: 20 μL<br />

Part No.<br />

N9303513<br />

Peak Identification<br />

1.<br />

Allicin<br />

0 2 4 6 8<br />

TIME (MIN.)<br />

Hyperforin in St. John’s Wort<br />

1<br />

CHROMATOGRAPHIC CONDITIONS<br />

Column: Brownlee Analytical C18<br />

Dimensions: 150 x 4.6 mm, 5 μm, 110 Å<br />

Sample: St. John’s Wort capsule<br />

Conc.: 4.17 mg/mL<br />

Detection: UV @ 270 nm<br />

Solvent: Methanol<br />

Mobile Phase: 0.01 N Phosphate Buffer, pH 2.5: Acetonitrile (15:85, v/v)<br />

Flow Rate: 1.2 mL/min.<br />

Autosampler: 15 °C<br />

Temperature: 30 °C<br />

Injection: 20 μL<br />

Part No.<br />

N9303513<br />

Peak Identification<br />

1.<br />

2.<br />

Hyperforin<br />

Adhyperforin<br />

0 2 4 6 8 10 12 14 16<br />

TIME (MIN.)<br />

1<br />

2<br />

Conventional Column Applications<br />

Dietary Supplements/Plant Extracts<br />

Phenethyl Glucosinolate<br />

Peak Identification<br />

1.<br />

Part No.<br />

Vitamins (Fat Soluble)<br />

CHROMATOGRAPHIC CONDITIONS<br />

Column: Brownlee Validated C18<br />

Dimensions: 250 x 4.6 mm, 5 μm, 100 Å<br />

Detection: UV @ 280 nm<br />

Solvent: Diethyl Ether<br />

Mobile Phase: Acetonitrile:Methanol (90:10, v/v)<br />

Time (min.) Flow (mL/min.)<br />

1.00 1.00<br />

5.00 1.00<br />

5.01 2.00<br />

50.0 2.00<br />

Temperature: 30 °C<br />

Part No.<br />

Phenethyl Glucosinolate<br />

CHROMATOGRAPHIC CONDITIONS<br />

Column: Brownlee Validated Aqueous C18<br />

Dimensions: 150 x 4.6 mm, 5 μm, 100 Å<br />

Conc.: 1000 μg/mL<br />

Detection: UV @ 210 nm<br />

Solvent: Water<br />

Mobile Phase: A: 50 mM Potassium Phosphate, pH 2.5 B: Acetonitrile<br />

Time (min.) %B<br />

0.0 0<br />

10 75<br />

11 0<br />

16 0<br />

Flow Rate: 1.0 mL/min.<br />

Temperature: Ambient<br />

Injection: 10 μL<br />

1<br />

2<br />

3<br />

N9303546<br />

0 10 20 30 40<br />

TIME (MIN.)<br />

4<br />

5<br />

6 7<br />

8<br />

N9303561<br />

9<br />

Peak Identification<br />

1.<br />

2.<br />

3.<br />

4.<br />

5.<br />

6.<br />

7.<br />

8.<br />

9.<br />

1<br />

0 2 4 6 8 10 12 14<br />

TIME (MIN.)<br />

Conc.<br />

mg/mL<br />

Solvent Front n/a<br />

Menadione 0.45<br />

(Vitamin K3)<br />

All-trans-retinol 0.34<br />

(Vitamin A)<br />

Vitamin D3 0.4<br />

Unknown<br />

n/a<br />

Tocopherol 2.4<br />

(Vitamin E)<br />

Tocopherol Acetate 2.4<br />

(Vitamin E Acetate)<br />

Unknown<br />

n/a<br />

Phylloquinone 0.84<br />

(Vitamin K1)<br />

Conventional Column Applications Liquid Chromatography<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

299


Conventional Column Applications<br />

Environmental<br />

Liquid Chromatography Conventional Column Applications<br />

Aldehydes and Ketones (DNPH derivatives)<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6 8<br />

7 9<br />

10 11<br />

12 13<br />

0 2 4 6 8 10 12 14<br />

TIME (MIN.)<br />

Explosives by EPA Method 8330<br />

Peak Identification<br />

1.<br />

2.<br />

3.<br />

4.<br />

5.<br />

6.<br />

7.<br />

8.<br />

9.<br />

10.<br />

11.<br />

12.<br />

13.<br />

14.<br />

CHROMATOGRAPHIC CONDITIONS<br />

Column: Brownlee Analytical C18<br />

Dimensions: 250 x 4.6 mm, 5 μm, 110 Å<br />

Conc.: 500 μg/mL each component<br />

Detection: UV @ 254 nm<br />

Solvent: Acetonitrile<br />

Mobile Phase: Water:Methanol (50:50, v/v)<br />

Flow Rate: 1.5 mL/min.<br />

Temperature: 27 °C<br />

Injection: 3 μL<br />

Part No.<br />

HMX<br />

RDX<br />

1, 3, 5-Trinitrobenzene<br />

1, 3-Dinitrobenzene<br />

Tetryl<br />

Nitrobenzene<br />

2, 4, 6-Trinitrotoluene<br />

2-Amino-4, 6-Dinitrotoluene<br />

4-Amino-2, 6-Dinitrotoluene<br />

2, 6-Dinitrotoluene<br />

2, 4-Dinitrotoluene<br />

2-Nitrotoluene<br />

4-Nitrotoluene<br />

3-Nitrotoluene<br />

N9303514<br />

1<br />

2<br />

3<br />

4<br />

6<br />

5<br />

0 2 4 6 8 10 12<br />

TIME (MIN.)<br />

DNPH Derivatives of:<br />

1. Formaldehyde<br />

2. Acetaldehyde<br />

3. Acetone<br />

4. Acrolein<br />

5. Propionaldehyde<br />

6. Crotonaldehyde<br />

7. MEK<br />

8. Methacrolein<br />

9. Butyraldehyde<br />

10. Benzaldehyde<br />

11. Valeraldehyde<br />

12. m-Tolualdehyde<br />

13. Hexanaldehyde<br />

CHROMATOGRAPHIC CONDITIONS<br />

Column: Brownlee Validated C18<br />

Dimensions: 150 x 4.6 mm, 5 μm, 100 Å<br />

Conc.: 30 μg/mL each, as derivative<br />

Mobile Phase: Solvent A: Water, Solvent B: Acetonitrile,<br />

Solvent C: Tetrahydrofuran, 50-30% A/30-65%<br />

B/20-5% C, 0-15 min.<br />

Flow Rate: 1.5 mL/min.<br />

Wavelength: 365 nm<br />

Temperature: 40 °C<br />

Injection: 10 μL<br />

Part No.<br />

N9303558<br />

Explosives by EPA Method 8330<br />

Peak Identification<br />

5<br />

1.<br />

2.<br />

3.<br />

Nitrobenzene<br />

2-Nitrotoluene<br />

4-Nitrotoluene<br />

6<br />

4. 3-Nitrotoluene<br />

1<br />

4<br />

11<br />

5. 1, 3-Dinitrobenzene<br />

8<br />

3<br />

6. 1, 3, 5-Trinitrobenzene<br />

2<br />

7<br />

7. 2, 6-Dinitrotoluene<br />

9<br />

8. 2, 4-Dinitrotoluene<br />

9<br />

12<br />

12. RDX<br />

13 14 13. Tetryl<br />

13<br />

9. 2, 4, 6-Trinitrotoluene<br />

7 11<br />

8<br />

10. 4-Amino-2, 6-Dinitrotoluene<br />

10<br />

11. 2-Amino-4, 6-Dinitrotoluene<br />

10<br />

14. HMX<br />

12<br />

0 2 4 6 8 10 12 14<br />

TIME (MIN.)<br />

CHROMATOGRAPHIC CONDITIONS<br />

Column: Brownlee Analytical Cyano<br />

Dimensions: 250 x 4.6 mm, 5 μm, 110 Å<br />

Conc.: 500 μg/mL each component<br />

Detection: UV @ 254 nm<br />

Solvent: Acetonitrile<br />

Mobile Phase: Water: Methanol (50:50, v/v)<br />

Flow Rate: 1.5 mL/min.<br />

Temperature: 27 °C<br />

Injection: 3 μL<br />

Part No.<br />

N9303523<br />

14<br />

300


Herbicides (Phenoxyacid Mix A)<br />

1<br />

5 6 7 8 9 10 11 12 13 14 15 16 17<br />

TIME (MIN.)<br />

Herbicides (Phenoxyacid Mix B)<br />

1<br />

2<br />

2<br />

3 4<br />

5<br />

Conventional Column Applications<br />

6 7<br />

12 14 16 18 20 22 24 26<br />

TIME (MIN.)<br />

3<br />

4 5<br />

6<br />

7<br />

8<br />

8<br />

9<br />

9<br />

1. Picloram<br />

2. Chloramben<br />

3. Dicamba<br />

4. Bentazon<br />

5. 2, 4-D<br />

6. Dichlorprop<br />

7. 2, 4, 5-TP<br />

8. Acifluorfen<br />

9. 1, 4-Dichlorobenzene (IS)<br />

Environmental<br />

CHROMATOGRAPHIC CONDITIONS<br />

Column: Brownlee Aqueous<br />

Dimensions: 150 x 4.6 mm, 5 μm, 100 Å<br />

Sample Diluent: Acetonitrile<br />

Conc.: 10 ppm each herbicide<br />

Detection: UV @ 225 nm<br />

Mobile Phase: A: 0.05% H 3 PO 4 B: Acetonitrile<br />

Time (min.) %B<br />

0 10<br />

10 45<br />

16 45<br />

22 90<br />

24 90<br />

25 10<br />

Flow Rate: 1.0 mL/min.<br />

Temperature: Ambient<br />

Injection: 10 μL<br />

Part No.<br />

N9303546<br />

1. 4-Nitrophenol<br />

2. MCPA<br />

3. 3, 5-Dichlorobenzoic acid<br />

4. MCPP<br />

5. 2, 4, 5-T<br />

6. 2, 4-DB<br />

7. 1, 4-Dichlorobenzene (IS)<br />

8. Dinoseb<br />

9. Pentachlorophenol<br />

CHROMATOGRAPHIC CONDITIONS<br />

Column: Brownlee Validated<br />

Dimensions: 150 x 4.6 mm, 5 μm, 100 Å<br />

Sample Diluent: Acetonitrile<br />

Conc.: 10 ppm each herbicide<br />

Detection: UV @ 225 nm<br />

Mobile Phase: A: 0.05% H 3 PO 4 B: Acetonitrile<br />

Time (min.) %B<br />

0 10<br />

10 45<br />

16 45<br />

22 90<br />

24 90<br />

25 10<br />

Flow Rate: 1.0 mL/min.<br />

Temperature: Ambient<br />

Injection: 10 μL<br />

Part No.<br />

N9303546<br />

Conventional Column Applications Liquid Chromatography<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

301


Conventional Column Applications<br />

Environmental<br />

Liquid Chromatography Conventional Column Applications<br />

Herbicides (Phenylurea)<br />

1<br />

2<br />

3<br />

0 10 20<br />

TIME (MIN.)<br />

Pesticides<br />

1<br />

2<br />

4<br />

5 6<br />

3<br />

4, 5<br />

6<br />

7<br />

8<br />

0 10 20 30<br />

TIME (MIN.)<br />

9<br />

7<br />

10 11<br />

8<br />

12<br />

1.<br />

2.<br />

3.<br />

4.<br />

5.<br />

6.<br />

7.<br />

8.<br />

9.<br />

10.<br />

11.<br />

12.<br />

13.<br />

14.<br />

15.<br />

16.<br />

17.<br />

9<br />

10<br />

Desisopropyl Atrazine<br />

Desethyl Atrazine<br />

Simazine<br />

Terbuthylazine Desethyl<br />

Cyanazine<br />

Methabenzthiazuron<br />

Chlortoluron<br />

Atrazine<br />

Secbumeton<br />

Isoproturon<br />

Diuron<br />

Terbumeton<br />

Terbuthylazine<br />

Linuron<br />

Flusilazole<br />

Ethofumerate<br />

Neburon<br />

13<br />

14<br />

15<br />

16<br />

17<br />

Peak Identification<br />

1.<br />

2.<br />

3.<br />

4.<br />

5.<br />

6.<br />

7.<br />

8.<br />

9.<br />

10.<br />

Tebuthiuron 2<br />

Thidiazuron 2<br />

Monuron 5<br />

Fluometuron 2<br />

Diuron 2<br />

Propanil 2<br />

Siduron 2<br />

Linuron 2<br />

Carbazole 5<br />

Diflubenzuron 2<br />

CHROMATOGRAPHIC CONDITIONS<br />

Column: Brownlee Validated C18<br />

Dimensions: 150 x 4.6 mm, 5 μm, 100 Å)<br />

Sample Diluent: Acetonitrile<br />

Detection: UV @ 245 nm<br />

Mobile Phase: A: 25 mM Phosphate Buffer, pH 2.5 B: Acetonitrile<br />

Time (min.) %B<br />

0 40<br />

8 40<br />

14 55<br />

18 55<br />

19 40<br />

Flow Rate: 1.5 mL/min.<br />

Temperature: Ambient<br />

Injection: 20 μL<br />

Part No.<br />

N9303558<br />

Conc.<br />

(μg/mL or ppm)<br />

CHROMATOGRAPHIC CONDITIONS<br />

Column: Brownlee Choice C18<br />

Dimensions: 150 x 4.6 mm, 5 μm, 60 Å<br />

Conc.: Approx. 10 ppm each pesticide<br />

Detection: UV @ 220 nm<br />

Solvent: Acetonitrile<br />

Mobile Phase: A: 20 mM K 2 HPO 4 , pH 7.0 B: Acetonitrile<br />

Time (min.) %B<br />

0 20<br />

10 40<br />

15 40<br />

30 70<br />

30.1 20<br />

Flow Rate: 1.2 mL/min.<br />

Temperature: Ambient<br />

Injection: 5 μL<br />

Part No.<br />

N9303628<br />

302


Pesticides (Carbamates)<br />

1 2 3 4<br />

5<br />

0 2 4 6 8 10<br />

TIME (MIN.)<br />

6<br />

7 8<br />

10<br />

Polynuclear Aromatic Hydrocarbons<br />

Peak Identification<br />

1.<br />

2.<br />

3.<br />

4.<br />

5.<br />

6.<br />

7.<br />

8.<br />

9.<br />

10.<br />

11.<br />

12.<br />

13.<br />

14.<br />

15.<br />

16.<br />

9<br />

Conc.<br />

(μg/mL)<br />

Naphthalene 100<br />

Acenaphthylene 100<br />

Acenaphthene 100<br />

Fluorene 100<br />

Phenanthrene 50<br />

Anthracene 100<br />

Fluoranthene 50<br />

Pyrene 50<br />

Benzo(a)anthracene 50<br />

Chrysene 50<br />

Benzo(b)fluoranthene 50<br />

Benzo(k)fluoranthene 50<br />

Benzo(a)pyrene 50<br />

Dibenzo(a,h)anthracene 50<br />

Benzo(ghi)perylene 50<br />

Indeno(1, 2, 3-cd)pyrene 50<br />

1<br />

2<br />

11<br />

3<br />

4<br />

Conventional Column Applications<br />

1.<br />

2.<br />

3.<br />

4.<br />

5.<br />

6.<br />

7.<br />

8.<br />

9.<br />

10.<br />

11.<br />

Aldicarb<br />

Aldicarb Sulfoxide<br />

Oxamyl<br />

Methomyl<br />

3-Hydroxycarbofuran<br />

Aldicarb<br />

Propoxur<br />

Carbofuran<br />

Carbaryl<br />

Methiocarb<br />

4-Bromo-3, 5-Dimethylcarbamate<br />

Part No.<br />

0 2 4 6 8 10 12 14 16 18<br />

TIME (MIN.)<br />

5<br />

6<br />

7 8<br />

9<br />

10<br />

11<br />

12<br />

13<br />

N9303570<br />

Environmental<br />

CHROMATOGRAPHIC CONDITIONS<br />

Column: Brownlee Validated Carbamate<br />

Dimensions: 50 x 4.6 mm, 3 μm, 100 Å<br />

Conc.: 50 μg/mL each<br />

Detection: UV @ 220 nm<br />

Solvent: Methanol<br />

Mobile Phase: A: 90:10 Water: Methanol B: 90:10 Methanol: Acetonitrile<br />

Time (min.) %B<br />

0 10<br />

10 90<br />

Flow Rate: 1.5 mL/min.<br />

Temperature: 27 °C<br />

Injection: 5 μL<br />

14 15 16<br />

CHROMATOGRAPHIC CONDITIONS<br />

Column: Brownlee Analytical PAH<br />

Dimensions: 150 x 3.2 mm, 5 μm, 110 Å<br />

Detection: UV @ 254 nm<br />

Solvent: 1:9 Methylene Chloride:Acetonitrile<br />

Mobile Phase: A: Purified Water B: Acetonitrile<br />

Time (min.) %B<br />

0 40<br />

7 60<br />

11 100<br />

18 40<br />

Flow Rate: 1.2 mL/min.<br />

Temperature: Ambient<br />

Injection: 5 μ<br />

Part No.<br />

N9303430<br />

Conventional Column Applications Liquid Chromatography<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

303


Conventional Column Applications<br />

Food and Flavors<br />

Liquid Chromatography Conventional Column Applications<br />

Heat Level Assay for Habeñero Nuggets<br />

Peak Identification<br />

1.<br />

2.<br />

3.<br />

Part No.<br />

Organic Acids in Grape Juice<br />

CHROMATOGRAPHIC CONDITIONS<br />

Column: Brownlee Choice Organic Acids<br />

Dimensions: 300 x 4.6 mm, 5 μm, 60 Å<br />

Conc.: Grape Juice: Water (50:50, v/v)<br />

Detection: UV @ 226 nm<br />

Solvent: Purified Water<br />

Mobile Phase: 100 mM Phosphate Buffer, pH 2.5<br />

Flow Rate: 0.5 mL/min.<br />

Temperature: Ambient<br />

Injection: 10 μL<br />

Part No.<br />

Unknown<br />

Capsaicin<br />

Dihydrocapsaicin<br />

0 1 2 3 4 5 6 7 8<br />

TIME (MIN.)<br />

CHROMATOGRAPHIC CONDITIONS<br />

Column: Brownlee Analytical C18<br />

Dimensions: 150 x 4.6 mm, 5 μm, 110 Å<br />

Conc.: 4000 μg/mL<br />

Detection: UV @ 280 nm<br />

Solvent: Ethanol<br />

Mobile Phase: A: 1% Acetic Acid in Water (v/v) B: Acetonitrile<br />

Time (min.) %B<br />

0 50<br />

2 50<br />

9 80<br />

12 80<br />

13 50<br />

Flow Rate: 1.0 mL/min.<br />

Temperature: Ambient<br />

Injection: 10 μL Habeñero Nugget Extract<br />

1<br />

N9303513<br />

2<br />

N9303634<br />

Peak Identification<br />

1.<br />

2.<br />

0 5 10 15 20 25 30 35 40<br />

TIME (MIN.)<br />

1<br />

2<br />

Tartaric Acid<br />

Malic Acid<br />

3<br />

Organic Acids Standard<br />

0 5 10 15 20 25 30 35 40<br />

TIME (MIN.)<br />

CHROMATOGRAPHIC CONDITIONS<br />

Column: Brownlee Choice Organic Acids<br />

Dimensions: 300 x 4.6 mm, 5 μm, 60 Å<br />

Detection: UV @ 226 nm<br />

Solvent: Purified Water<br />

Mobile Phase: 100 mM Phosphate Buffer, pH 2.5<br />

Flow Rate: 0.5 mL/min.<br />

Temperature: Ambient<br />

Injection: 10 μL<br />

Part No.<br />

Sugars<br />

N9303634<br />

CHROMATOGRAPHIC CONDITIONS<br />

Column: Brownlee Validated Amino<br />

Dimensions: 150 x 4.6 mm, 3 μm, 100 Å<br />

Detection: Refractive Index @ 35 °C<br />

Solvent: Mobile Phase<br />

Mobile Phase: Water:Acetonitrile (25:75, v/v)<br />

Flow Rate: 0.8 mL/min.<br />

Temperature: 35 °C<br />

Injection: 20 μL<br />

Part No.<br />

1<br />

2<br />

3<br />

Peak Identification<br />

1.<br />

2.<br />

3.<br />

4.<br />

5.<br />

Fructose 2.0<br />

Glucose 2.1<br />

Sucrose 4.0<br />

Maltose 4.5<br />

Lactose 4.4<br />

N9303534<br />

Conc.<br />

(mg/mL)<br />

4<br />

Peak Identification<br />

1.<br />

2.<br />

3.<br />

4.<br />

5.<br />

Tartaric Acid 1<br />

Quinic Acid 1<br />

Malic Acid 1<br />

Citric Acid<br />

Fumaric Acid<br />

5<br />

1<br />

2<br />

Conc.<br />

(μg/mL)<br />

0 2 4 6 8 10 12 14<br />

TIME (MIN.)<br />

3<br />

4<br />

5<br />

304


Analgesic Acetaminophen<br />

and Narcotic Analgesics<br />

Peak Identification<br />

1.<br />

2.<br />

3.<br />

4.<br />

Acetaminophen<br />

Codeine<br />

Oxycodone<br />

Hydroxycodone<br />

0 1 2 3 4 5 6 7 8 9<br />

TIME (MIN.)<br />

CHROMATOGRAPHIC CONDITIONS<br />

Column: Brownlee Choice<br />

Dimensions: 150 x 4.6 mm, 5 μm, 60 Å<br />

Conc.: 100 μg/mL<br />

Detection: UV @ 280 nm<br />

Solvent: Mobile Phase<br />

Mobile Phase: 20 mM Ammonium Acetate, pH 4.5: Acetonitrile (85:15, v/v)<br />

Flow Rate: 1.0 mL/min.<br />

Temperature: 30 °C<br />

Injection: 5 μL<br />

Part No.<br />

N9303618<br />

Analgesic Acetaminophen and Narcotic Analgesics<br />

Peak Identification<br />

U.<br />

1.<br />

2.<br />

3.<br />

4.<br />

5.<br />

* (Ret. Time (min.), Tailing, Resolution)<br />

Part No.<br />

N9303561<br />

Conc.<br />

(μg/mL)<br />

Unknown<br />

unknown<br />

(3.1, NA, NA)*<br />

1<br />

2<br />

Morphine Sulfate 204<br />

(3.3, 1.0, 1.8)*<br />

Acetaminophen 92<br />

3<br />

(5.0, 1.1, 14.1)*<br />

4<br />

Codeine Phosphate 216<br />

(5.5, 1.4, 2.6)*<br />

5<br />

Oxycodone HCl 206<br />

U<br />

(7.5, 1.4, 8.5)*<br />

Hydrocodone Bitartrate 218 0 1 2 3 4 5 6 7 8 9<br />

(8.9, 1.4, 5.0)*<br />

TIME (MIN.)<br />

CHROMATOGRAPHIC CONDITIONS<br />

Column: Brownlee Validated C18<br />

Dimensions: 250 x 4.6 mm, 5 μm, 100 Å<br />

Sample: Raw Material Mix<br />

Detection: UV @ 235 nm<br />

Solvent: Mobile Phase<br />

Mobile Phase: A: 10 mm Potassium Phosphate, pH 2.8<br />

B: Acetonitrile:Methanol (90:10 v/v) (85A:15B, v/v)<br />

Flow Rate: 1.0 mL/min.<br />

Temperature: 27 °C<br />

Injection: 4.0 μL<br />

1<br />

2<br />

3<br />

Conventional Column Applications<br />

4<br />

Antiarrhythmic Atenolol<br />

Peak Identification<br />

1.<br />

2.<br />

1<br />

Pharmaceutical<br />

0 2 4 6 8 10 12<br />

TIME (MIN.)<br />

CHROMATOGRAPHIC CONDITIONS<br />

Column: Brownlee Choice Basix<br />

Dimensions: 150 x 4.6 mm, 5 μm, 60 Å<br />

Conc.: 1 mg/mL<br />

Detection: UV @ 225 nm<br />

Solvent: Water:Methanol (7:3, v/v)<br />

Mobile Phase: Acetonitrile: 20 mM Ammonium Acetate, pH 4.5 (80:20, v/v)<br />

Flow Rate: 1.2 mL/min.<br />

Temperature: 25 °C<br />

Injection: 1 μL<br />

Part No.<br />

Uracil (marker)<br />

Atenolol<br />

N9303618<br />

Antiarrhythmic Calcium Channel Blockers<br />

Peak Identification<br />

1.<br />

2.<br />

3.<br />

4.<br />

5.<br />

2<br />

CHROMATOGRAPHIC CONDITIONS<br />

Column: Brownlee Validated Cyano<br />

Dimensions: 150 x 4.6 mm, 5 μm, 100 Å<br />

Conc.: 100 mg/mL<br />

Detection: 235 nm<br />

Solvent: Acetonitrile:Water (1:1)<br />

Mobile Phase: 20 mM Potassium Phosphate Monobasic, pH 3.0:<br />

Acetonitrile (70:30, v/v)<br />

Flow Rate: 1.2 mL/min.<br />

Temperature: 30 °C (±1 °C)<br />

Injection: 5 μL<br />

Part No.<br />

Diltiazem<br />

Nifedipine Impurity<br />

Verapamil<br />

Nifedipine<br />

Nicardipine<br />

0 1 2 3 4 5 6 7 8 9<br />

TIME (MIN.)<br />

N9303575<br />

1<br />

2<br />

3<br />

4<br />

5<br />

Conventional Column Applications Liquid Chromatography<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

305


Conventional Column Applications<br />

Pharmaceutical<br />

Liquid Chromatography Conventional Column Applications<br />

Antibiotic Amoxicillin<br />

Peak Identification<br />

1.<br />

CHROMATOGRAPHIC CONDITIONS<br />

Column: Brownlee Validated IBD<br />

Dimensions: 150 x 4.6 mm, 5 μm, 100 Å<br />

Conc.: 1.5 mg/mL<br />

Detection: UV @ 270 nm<br />

Solvent: Acetonitrile:Water (10:90, v/v)<br />

Mobile Phase: 10 mM Ammonium Formate, pH 2.5: Acetonitrile (95:5, v/v)<br />

Flow Rate: 1.2 mL/min.<br />

Temperature: 30 °C<br />

Injection: 5 μL<br />

Part No.<br />

Amoxicillin<br />

N9303582<br />

0 1 2 3 4 5 6<br />

TIME (MIN.)<br />

Antibiotic Sulfamethoxazole, Trimethoprim,<br />

and Naphthoate<br />

Peak Identification<br />

1.<br />

2.<br />

3.<br />

Part No.<br />

Trimethoprim<br />

Sulfamethoxazole<br />

Naphthoate<br />

0 2 4 6 8 10 12 14<br />

TIME (MIN.)<br />

CHROMATOGRAPHIC CONDITIONS<br />

Column: Brownlee Choice C18<br />

Dimensions: 150 x 4.6 mm, 5 μm, 60 Å<br />

Conc.: 100 μg/mL<br />

Detection: UV @ 220 nm<br />

Solvent: Water:Methanol (1:1, v/v)<br />

Mobile Phase: 10 mM Ammonium Formate, pH to 3.0<br />

with Formic Acid: Methanol (50:50, v/v)<br />

Flow Rate: 1.0 mL/min.<br />

Temperature: Ambient<br />

Injection: 10 μL<br />

N9303628<br />

1<br />

2<br />

3<br />

1<br />

Antidepressants (Tricyclic)<br />

Peak Identification<br />

1.<br />

2.<br />

3.<br />

4.<br />

5.<br />

6.<br />

7.<br />

CHROMATOGRAPHIC CONDITIONS<br />

Column: Brownlee Choice Basix<br />

Dimensions: 150 x 4.6 mm, 5 μm, 60 Å<br />

Conc.: 100 μg/mL<br />

Detection: UV @ 254 nm<br />

Solvent: Mobile Phase<br />

Mobile Phase: Acetonitrile: 50 mM KH 2 PO 4 pH3: Methanol (60:25:15, v/v)<br />

Flow Rate: 1.2 mL/min.<br />

Temperature: 30 °C<br />

Injection: 10 μL<br />

Part No.<br />

Doxepin<br />

Nordoxepin<br />

Amitriptyline<br />

Imipramine<br />

Desimipramine<br />

Nortriptyline<br />

Protriptyline<br />

Corticosteroids<br />

Part No.<br />

1<br />

1 2<br />

3<br />

4<br />

0 1 2 3 4 5 6 7 8 9<br />

TIME (MIN.)<br />

N9303618<br />

N9303628<br />

Peak Identification<br />

1.<br />

2.<br />

3.<br />

2 3<br />

0 1 2 3 4<br />

TIME (MIN.)<br />

CHROMATOGRAPHIC CONDITIONS<br />

Column: Brownlee Choice C18<br />

Dimensions: 150 x 4.6 mm, 5 μm, 60 Å<br />

Conc.: 100 μg/mL each<br />

Detection: UV @ 254 nm<br />

Solvent: Water:Acetonitrile (1:1)<br />

Mobile Phase: Water:Methanol (50:50, v/v)<br />

Flow Rate: 1.0 mL/min.<br />

Temperature: Ambient<br />

Injection: 5 μL<br />

5<br />

6<br />

7<br />

Uracil<br />

Corticosterone<br />

Deoxycorticosterone<br />

306


Corticosteroids Standards<br />

Peak Identification<br />

1.<br />

2.<br />

3.<br />

4.<br />

5.<br />

6.<br />

CHROMATOGRAPHIC CONDITIONS<br />

Column: Brownlee Validated C18<br />

Dimensions: 150 x 4.6 mm, 5 μm, 100 Å<br />

Conc.: 100 μg/mL<br />

Detection: UV @ 220 nm<br />

Solvent: Mobile Phase<br />

Mobile Phase: Water:Methanol (30:70, v/v)<br />

Flow Rate: 1.0 mL/min.<br />

Temperature: 30 °C<br />

Injection: 5 μL<br />

Part No.<br />

Uracil<br />

Triamcinolone<br />

Hydrocortisone<br />

Dexamethasone<br />

Corticosterone<br />

Deoxycorticosterone<br />

N9303558<br />

1<br />

0 1 2 3 4 5 6<br />

TIME (MIN.)<br />

Narcotic Analgesic Hydrocodone Bitartrate by USP 25<br />

Impurities resolved<br />

from primary peak.<br />

0 1 2 3 4<br />

TIME (MIN.)<br />

2<br />

0 1 2 3 4<br />

TIME (MIN.)<br />

3<br />

4<br />

5<br />

Conventional Column Applications<br />

6<br />

1<br />

Hormones ß-Estradiol, Norethindrone,<br />

and Ethynyl Estradiol<br />

Peak Identification<br />

1.<br />

2.<br />

3.<br />

CHROMATOGRAPHIC CONDITIONS<br />

Column: Brownlee Validated C18<br />

Dimensions: 150 x 4.6 mm, 5 μm, 100 Å<br />

Conc.: 333 μg/mL<br />

Detection: UV @ 230 nm<br />

Solvent: Acetonitrile:Water (80:20, v/v)<br />

Mobile Phase: 10 mM Ammonium Formate, pH 3.0:<br />

Acetonitrile (60:40, v/v)<br />

Flow Rate: 1.0 mL/min.<br />

Temperature: 30 °C<br />

Injection: 10 μL<br />

Part No.<br />

ß-Estradiol<br />

Norethindrone<br />

Ethynyl Estradiol<br />

N9303558<br />

Pharmaceutical<br />

0 2 4 6 8 10 12 14<br />

TIME (MIN.)<br />

Ret. Time Inj. %<br />

Peak Identification (min.) RSD (n=5)<br />

1.<br />

Hydrocodone Bitartrate 3.1 0.37%<br />

CHROMATOGRAPHIC CONDITIONS<br />

Column: Brownlee Analytical Silica<br />

Dimensions: 250 x 4.6 mm, 5 μm, 100 Å<br />

Sample: Assay Standard<br />

Conc.: 1 μg/mL<br />

Detection: UV @ 280 nm<br />

Solvent: Mobile Phase<br />

Mobile Phase: A: 800 mM Acetonitrile; 4 mL<br />

Water; 1 mL Diethylamine<br />

B: Methanol (55A:45B, v/v)<br />

Flow Rate: 1.5 mL/min.<br />

Temperature: 27 °C<br />

Injection: 20 μL<br />

Part No.<br />

N9303526<br />

1<br />

2<br />

3<br />

Conventional Column Applications Liquid Chromatography<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

307


Conventional Columns<br />

Brownlee Analytical Conventional Columns<br />

Liquid Chromatography Conventional Columns<br />

Brownlee Analytical Amino<br />

Ideal column for mono and disaccharide analyses. Most<br />

popular amino-based stationary phase. Routine analysis of<br />

simple sugars, using isocratic elution and a refractive index<br />

detector or an evaporative light scattering detector.<br />

pH range: 2.5 to 7.5 - Temperature limit: 80 °C<br />

Pore size: 110 Å - Carbon load: 2% - End Cap: No<br />

Length<br />

Particle<br />

Phase mm ID mm Size μm Part No. Each (€)<br />

Amino 50 4.6 3 N9303502 356<br />

Amino 100 4.6 3 N9303500 381<br />

Amino 150 4.6 3 N9303501 407<br />

Amino 50 4.6 5 N9303506 343<br />

Amino 100 4.6 5 N9303503 369<br />

Amino 150 4.6 5 N9303504 381<br />

Amino 250 4.6 5 N9303505 433<br />

Brownlee Analytical C8<br />

Shorter retention times for hydrophobic compounds.<br />

Reliable performance with symmetrical peak shapes<br />

for neutral to acidic compounds.<br />

pH range: 2.5 to 7.5 - Temperature limit: 80 °C - Pore size: 100 Å<br />

Carbon load: 7% - End Cap: Yes<br />

Length<br />

Particle<br />

Phase mm ID mm Size μm Part No. Each (€)<br />

C8 30 4.6 5 N9303521 326<br />

C8 100 4.6 5 N9303515 369<br />

C8 150 4.0 5 N9303516 389<br />

C8 150 4.6 5 N9303517 389<br />

C8 200 4.6 5 N9303518 407<br />

C8 250 4.0 5 N9303519 433<br />

C8 250 4.6 5 N9303520 433<br />

Brownlee Analytical C18<br />

Suitable for a wide range of acidic to neutral hydrophobic<br />

compounds. Excellent all purpose column.<br />

pH range: 2.5 to 7.5 - Temperature limit: 80 °C<br />

Pore size: 110 Å - Carbon load: 13% - End Cap: Yes<br />

Length<br />

Particle<br />

Phase mm ID mm Size μm Part No. Each (€)<br />

C18 30 4.6 3 N9303509 339<br />

C18 50 4.6 3 N9303510 356<br />

C18 100 4.6 3 N9303507 381<br />

C18 150 4.6 3 N9303508 407<br />

C18 100 4.0 5 N9303511 369<br />

C18 100 4.6 5 N9303512 369<br />

C18 150 4.6 5 N9303513 389<br />

C18 250 4.6 5 N9303514 433<br />

Brownlee Analytical Cyano<br />

Suitable for analyses of a wide range of compounds<br />

from acidic through slightly basic. Highly base-deactivated<br />

spherical silica.<br />

pH range: 2.5 to 7.5 - Temperature limit: 80 °C - Pore size: 110 Å<br />

Carbon load: 4% - End Cap: Yes<br />

Length<br />

Particle<br />

Phase mm ID mm Size μm Part No. Each (€)<br />

Cyano 150 4.6 5 N9303522 381<br />

Cyano 250 4.6 5 N9303523 433<br />

Brownlee Analytical PAH<br />

Specifically designed for challenging analyses of<br />

polynuclear aromatic hydrocarbons.<br />

pH range: 2.5 to 7.5 - Temperature limit: 80 °C - Pore size: 110 Å<br />

End Cap: Yes<br />

Length<br />

Particle<br />

Phase mm ID mm Size μm Part No. Each (€)<br />

PAH 100 4.6 5 N9303527 353<br />

PAH 150 3.2 5 N9303430 517<br />

PAH 150 4.6 5 N9303529 521<br />

PAH 200 4.6 5 N9303528 534<br />

PAH 250 2.1 5 N9303530 534<br />

PAH 250 4.6 5 N9303531 534<br />

Brownlee Analytical Phenyl<br />

Unique selectivity especially for aromatic compounds.<br />

pH range: 2.5 to 7.5 - Temperature limit: 80 °C - Carbon load: 6%<br />

Pore size: 110 Å - End Cap: Yes<br />

Length<br />

Particle<br />

Phase mm ID mm Size μm Part No. Each (€)<br />

Phenyl 150 4.6 5 N9303524 389<br />

Brownlee Analytical Silica<br />

Good general purpose packing for normal phase separations.<br />

pH range: 2.5 to 7.5 - Temperature limit: 80 °C - Pore size: 110 Å<br />

End Cap: No<br />

Length<br />

Particle<br />

Phase mm ID mm Size μm Part No. Each (€)<br />

Silica 150 4.6 5 N9303525 389<br />

Silica 250 4.6 5 N9303526 433<br />

308


Conventional Columns<br />

Brownlee Aquapore and Bio Conventional Columns<br />

Brownlee Aquapore AX-300<br />

Brownlee Bio C8<br />

Used for Ion Exchange chromatography.<br />

Pore Size: 300 Å<br />

Length<br />

Particle<br />

Phase mm ID mm Size μm Part No. Each (€)<br />

AX-300 250 4.6 7 07120040 1312<br />

Brownlee Aquapore Octyl C8<br />

Used for Reversed Phase chromatography.<br />

Pore Size: 300 Å<br />

Length<br />

Particle<br />

Phase mm ID mm Size μm Part No. Each (€)<br />

C8 100 1.0 7 07120096 547<br />

C8 250 1.0 7 07120097 547<br />

C8 250 4.6 7 07120033 738<br />

Brownlee Aquapore ODS C18<br />

Silica-based support suitable for the separation of large<br />

biopolymers. Microbore columns increase sensitivity,<br />

reduce sample size, and have better compatibility<br />

with LC/MS interfaces.<br />

Pore Size: 300 Å<br />

Length<br />

Particle<br />

Phase mm ID mm Size μm Part No. Each (€)<br />

C18 100 1.0 7 07120099 547<br />

C18 250 4.6 7 07120073 636<br />

Wide-pore HPLC Column. High proportion of pore/surface<br />

area available for large molecule separations.<br />

Pore Size: 300 Å - Carbon Load: 6% - End Cap: Yes<br />

Length<br />

Particle<br />

Phase mm ID mm Size μm Part No. Each (€)<br />

C8 50 2.1 5 N9303664 433<br />

C8 50 4.6 5 N9303665 433<br />

C8 100 2.1 5 N9303656 471<br />

C8 100 4.6 5 N9303657 471<br />

C8 150 2.1 5 N9303658 508<br />

C8 150 4.6 5 N9303659 508<br />

C8 200 2.1 5 N9303660 547<br />

C8 200 4.6 5 N9303661 547<br />

C8 250 2.1 5 N9303662 580<br />

C8 250 4.6 5 N9303663 580<br />

Brownlee Bio C18<br />

Excellent for separating peptides or proteins.<br />

Wide-pore HPLC Column.<br />

Pore Size: 300 Å - Carbon Load: 6% - End Cap: Yes<br />

Length<br />

Particle<br />

Phase mm ID mm Size μm Part No. Each (€)<br />

C18 50 2.1 5 N9303654 433<br />

C18 50 4.6 5 N9303655 433<br />

C18 100 2.1 5 N9303646 471<br />

C18 100 4.6 5 N9303647 471<br />

C18 150 2.1 5 N9303648 508<br />

C18 150 4.6 5 N9303649 508<br />

C18 200 2.1 5 N9303650 547<br />

C18 200 4.6 5 N9303651 547<br />

C18 250 2.1 5 N9303652 580<br />

C18 250 4.6 5 N9303653 580<br />

Conventional Columns Liquid Chromatography<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

309


Conventional Columns<br />

Brownlee CHOICE Conventional Columns<br />

Liquid Chromatography Conventional Columns<br />

Brownlee CHOICE Basix<br />

Excellent choice for analytes containing amine<br />

group functionality.<br />

pH range: 2.5 to 7.5 - Temperature limit: 80 °C -<br />

Pore Size: 60 Å - Carbon Load: 12% - End Cap: Yes<br />

Length<br />

Particle<br />

Phase mm ID mm Size μm Part No. Each (€)<br />

Basix 30 2.1 3 N9303610 471<br />

Basix 50 2.1 3 N9303611 471<br />

Basix 100 2.1 3 N9303608 508<br />

Basix 100 4.6 3 N9303609 508<br />

Basix 150 4.6 3 N9303612 547<br />

Basix 50 2.1 5 N9303615 433<br />

Basix 50 4.6 5 N9303616 433<br />

Basix 100 2.1 5 N9303613 471<br />

Basix 100 4.6 5 N9303614 471<br />

Basix 150 2.1 5 N9303617 504<br />

Basix 150 4.6 5 N9303618 508<br />

Basix 250 4.6 5 N9303619 580<br />

Brownlee CHOICE C18<br />

Excellent choice for LC/MS. Highly retentive phase for<br />

hydrophobic and slightly polar analytes.<br />

pH range: 2.5 to 7.5 - Temperature limit: 80 °C -<br />

Pore Size: 60 Å - Carbon Load: 27% - End Cap: Yes<br />

Length<br />

Particle<br />

Phase mm ID mm Size μm Part No. Each (€)<br />

C18 50 2.1 3 N9303622 471<br />

C18 50 4.6 3 N9303623 471<br />

C18 100 2.1 3 N9303620 508<br />

C18 100 4.6 3 N9303621 508<br />

C18 150 4.6 3 N9303624 547<br />

C18 50 2.1 5 N9303626 433<br />

C18 100 2.1 5 N9303625 471<br />

C18 150 2.1 5 N9303627 508<br />

C18 150 4.6 5 N9303628 508<br />

C18 250 2.1 5 N9303629 580<br />

C18 250 4.6 5 N9303630 580<br />

Brownlee CHOICE Organic Acids<br />

Enhanced retention and selectivity for polar organic acids.<br />

Retention is stable and reproducible even with 100%<br />

aqueous mobile phase specified in the AOAC method.<br />

pH range: 2.5 to 7.5 - Temperature limit: 80 °C -<br />

Pore Size: 60 Å - End Cap: No<br />

Length<br />

Particle<br />

Phase mm ID mm Size μm Part No. Each (€)<br />

Organic Acids 150 4.6 5 N9303631 721<br />

Organic Acids 250 2.1 5 N9303632 598<br />

Organic Acids 250 4.6 5 N9303633 764<br />

Organic Acids 300 4.6 5 N9303634 790<br />

Brownlee CHOICE Propyl<br />

Highly retentive for basic analytes. Excellent separation of<br />

nucleosides, nucleotides, purines, pyrimidines halogenated<br />

compounds, beta blockers and tricyclic antidepressants.<br />

pH range: 2.5 to 7.5 - Temperature limit: 80 °C -<br />

Pore Size: 60 Å - Carbon Load: 17% - End Cap: Yes<br />

Length<br />

Particle<br />

Phase mm ID mm Size μm Part No. Each (€)<br />

PFP Propyl 50 2.1 3 N9303636 483<br />

PFP Propyl 50 4.6 3 N9303637 483<br />

PFP Propyl 100 4.6 3 N9303635 521<br />

PFP Propyl 30 2.1 5 N9303640 453<br />

PFP Propyl 50 2.1 5 N9303641 453<br />

PFP Propyl 50 4.6 5 N9303642 453<br />

PFP Propyl 100 2.1 5 N9303638 483<br />

PFP Propyl 100 4.6 5 N9303639 483<br />

PFP Propyl 150 2.1 5 N9303643 521<br />

PFP Propyl 150 4.6 5 N9303644 521<br />

PFP Propyl 250 4.6 5 N9303645 598<br />

310


Conventional Columns<br />

Brownlee Spheri-5 and Validated Conventional Columns<br />

Brownlee Spheri-5 ®<br />

Small pore silica-based sorbent for separating small<br />

molecules both non-functional and polyfunctional<br />

C8 and C18 are available.<br />

Length: 250 mm - ID: 4.6 mm - Pore Size: 80 Å<br />

Length<br />

Particle<br />

Phase mm ID mm Size μm Part No. Each (€)<br />

C2 250 4.6 10 07120005 483<br />

C8 250 4.6 5 07120012 483<br />

C18 250 4.6 5 07120016 573<br />

C18 250 4.6 10 07120001 483<br />

C18 ODS 250 4.6 5 07120019 483<br />

Silica 250 4.6 5 07120023 611<br />

Brownlee Validated TM Amino<br />

Good for normal phase analytes of mono- and disaccharides<br />

or similar compounds.<br />

pH range: 2.5 to 7.5 - Temperature limit: 80 °C -<br />

Particle Size: 5 μm - Pore Size: 100 Å - Carbon Load: 2%<br />

Length<br />

Particle<br />

Phase mm ID mm Size μm Part No. Each (€)<br />

Amino 100 2.1 5 N9303532 471<br />

Amino 150 2.1 5 N9303533 508<br />

Amino 150 4.6 5 N9303534 508<br />

Amino 200 4.6 5 N9303535 547<br />

Amino 250 4.6 5 N9303536 580<br />

Brownlee Validated Aqueous C18<br />

Highly base deactivated. Compatible with highly aqueous<br />

mobile phases.<br />

pH range: 2.5 to 7.5 - Temperature limit: 80 °C -<br />

Pore Size: 100 Å - Carbon Load: 15% - End Cap: No<br />

Length<br />

Particle<br />

Phase mm ID mm Size μm Part No. Each (€)<br />

Aqueous C18 30 2.1 3 N9303540 483<br />

Aqueous C18 50 2.1 3 N9303541 483<br />

Aqueous C18 50 4.6 3 N9303542 483<br />

Aqueous C18 100 2.1 3 N9303537 521<br />

Aqueous C18 100 4.6 3 N9303538 521<br />

Aqueous C18 150 2.1 3 N9303539 547<br />

Aqueous C18 30 4.6 5 N9303550 453<br />

Aqueous C18 100 2.1 5 N9303543 483<br />

Aqueous C18 100 4.6 5 N9303544 483<br />

Aqueous C18 150 2.1 5 N9303545 521<br />

Aqueous C18 150 4.6 5 N9303546 521<br />

Aqueous C18 200 4.6 5 N9303547 560<br />

Aqueous C18 250 2.1 5 N9303548 598<br />

Aqueous C18 250 4.6 5 N9303549 598<br />

Brownlee Validated C1<br />

Least retentive reversed phase hydrocarbon packing.<br />

pH range: 2.5 to 7.5 - Temperature limit: 80 °C -<br />

Pore Size: 100 Å - Carbon Load: 5% - End Cap: No<br />

Length<br />

Particle<br />

Phase mm ID mm Size μm Part No. Each (€)<br />

C1 150 4.6 5 N9303718 500<br />

C1 250 4.6 5 N9303719 571<br />

Brownlee Validated C4<br />

High bonding coverage and base deactivation. Less retention<br />

than C18 or C8 phases.<br />

pH range: 2.5 to 7.5 - Temperature limit: 80 °C -<br />

Pore Size: 100 Å - Carbon Load: 9% - End Cap: Yes<br />

Length<br />

Particle<br />

Phase mm ID mm Size μm Part No. Each (€)<br />

C4 150 4.6 5 N9303720 500<br />

C4 250 4.6 5 N9303721 571<br />

Brownlee Validated C8<br />

Retentive, high purity base-deactivated reversed phase packing.<br />

pH range: 2.5 to 7.5 - Temperature limit: 80 °C -<br />

Pore Size: 80 Å - Carbon Load: 12% - End Cap: Yes<br />

Length<br />

Particle<br />

Phase mm ID mm Size μm Part No. Each (€)<br />

C8 100 2.1 5 N9303564 471<br />

C8 100 4.6 5 N9303565 471<br />

C8 150 2.1 5 N9303566 508<br />

C8 150 4.6 5 N9303567 508<br />

C8 250 4.6 5 N9303568 580<br />

Brownlee Validated C18<br />

Excellent general purpose phase column.<br />

Retentive high purity packing.<br />

pH range: 2.5 to 7.5 - Temperature limit: 80 °C -<br />

Pore Size: 100 Å - Carbon Load: 20% - End Cap: Yes<br />

Length<br />

Particle<br />

Phase mm ID mm Size μm Part No. Each (€)<br />

C18 100 2.1 3 N9303551 508<br />

C18 100 4.6 3 N9303552 508<br />

C18 50 2.1 5 N9303562 433<br />

C18 50 4.6 5 N9303563 433<br />

C18 100 2.1 5 N9303553 471<br />

C18 100 4.6 5 N9303554 471<br />

C18 150 2.1 5 N9303556 508<br />

C18 150 4.0 5 N9303557 508<br />

C18 150 4.6 5 N9303558 508<br />

C18 200 4.6 5 N9303559 547<br />

C18 250 2.1 5 N9303560 580<br />

C18 250 4.6 5 N9303561 580<br />

Conventional Columns Liquid Chromatography<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

311


Conventional Columns<br />

Brownlee Validated Conventional Columns<br />

Liquid Chromatography Conventional Columns<br />

Brownlee Validated TM Carbamate<br />

A unique stationary phase bonded to a 3μm silica<br />

specifically designed for carbamate analysis. This column<br />

is compatible with fluorescence or LC/MS detection.<br />

Validated Carbamate column has much faster analysis,<br />

which will significantly reduce solvent usage.<br />

pH range: 2.5 to 7.5 - Temperature limit: 80 °C - Pore Size: 100 Å<br />

Length<br />

Particle<br />

Phase mm ID mm Size μm Part No. Each (€)<br />

Carbamate 50 4.6 3 N9303570 644<br />

Carbamate 100 4.6 3 N9303569 644<br />

Carbamate 250 4.6 3 N9303571 611<br />

Brownlee Validated Cyano<br />

High purity Cyano phase with few silanol sites. Less sensitive<br />

to small amounts of water present in the mobile phase.<br />

pH range: 2.5 to 7.5 - Temperature limit: 80 °C -<br />

Pore Size: 100 Å - Carbon Load: 10% - End Cap: Yes<br />

Length<br />

Particle<br />

Phase mm ID mm Size μm Part No. Each (€)<br />

Cyano 30 4.6 5 N9303578 433<br />

Cyano 100 2.1 5 N9303572 471<br />

Cyano 100 4.6 5 N9303573 471<br />

Cyano 150 2.1 5 N9303574 508<br />

Cyano 150 4.6 5 N9303575 508<br />

Cyano 200 4.6 5 N9303576 547<br />

Cyano 250 4.6 5 N9303577 580<br />

Brownlee Validated IBD<br />

Unique selectivity and a high level of base-deactivation.<br />

Reduces or eliminates the need for mobile phase additives.<br />

pH range: 2.5 to 7.5 - Temperature limit: 80 °C -<br />

Pore Size: 100 Å - Carbon Load: 12% - End Cap: No<br />

Length<br />

Particle<br />

Phase mm ID mm Size μm Part No. Each (€)<br />

IBD 30 4.6 3 N9303594 433<br />

IBD 50 2.1 3 N9303595 433<br />

IBD 50 4.6 3 N9303596 433<br />

IBD 100 2.1 3 N9303590 521<br />

IBD 100 4.6 3 N9303591 521<br />

IBD 150 2.1 3 N9303592 547<br />

IBD 150 4.6 3 N9303593 547<br />

IBD 30 1.0 5 N9303585 478<br />

IBD 30 2.1 5 N9303586 453<br />

IBD 30 4.6 5 N9303587 453<br />

Length<br />

Particle<br />

Phase mm ID mm Size μm Part No. Each (€)<br />

IBD 50 2.1 5 N9303588 453<br />

IBD 50 4.6 5 N9303589 453<br />

IBD 100 2.1 5 N9303579 433<br />

IBD 100 4.6 5 N9303580 433<br />

IBD 150 2.1 5 N9303581 521<br />

IBD 150 4.6 5 N9303582 521<br />

IBD 200 4.6 5 N9303583 560<br />

IBD 250 4.6 5 N9303584 598<br />

Brownlee Validated PFP<br />

Unique selectivity for compounds containing<br />

organohalogens or other basic functional groups.<br />

pH range: 2.5 to 7.5 - Temperature limit: 80 °C -<br />

Pore Size: 100 Å - Carbon Load: 7% - End Cap: Yes<br />

Length<br />

Particle<br />

Phase mm ID mm Size μm Part No. Each (€)<br />

PFP 50 2.1 5 N9303601 453<br />

PFP 100 4.6 5 N9303597 433<br />

PFP 150 2.1 5 N9303598 521<br />

PFP 150 4.6 5 N9303599 521<br />

PFP 250 4.6 5 N9303600 598<br />

Brownlee Validated Phenyl<br />

High purity, highly retentive base-deactivated phase,<br />

especially designed for aromatic analytes.<br />

pH range: 2.5 to 7.5 - Temperature limit: 80 °C -<br />

Pore Size: 100 Å - Carbon Load: 10% - End Cap: Yes<br />

Length<br />

Particle<br />

Phase mm ID mm Size μm Part No. Each (€)<br />

Phenyl 50 1.0 3 N9303604 496<br />

Phenyl 100 2.1 3 N9303602 508<br />

Phenyl 100 4.6 3 N9303603 508<br />

Phenyl 150 2.1 5 N9303605 508<br />

Phenyl 150 4.6 5 N9303606 508<br />

Phenyl 250 4.6 5 N9303607 580<br />

312


Conventional Columns<br />

Guard Cartridges and Accessories<br />

Guard Cartridge Accessories<br />

Description Part No. Each (€)<br />

10 mm guard cartridge holder with filter N9303713 139<br />

10 mm guard cartridge holder without filter N9303712 114<br />

High pressure filter N9303711 114<br />

Peek tip standard fittings N9303714 17<br />

Replacement cap frits 2.0 mm, 2.0 μm N9303717 44<br />

Replacement cap frits 4.0 mm, 0.5 μm N9303716 44<br />

Replacement cap frits 4.0 mm, 2.0 μm N9303715 37<br />

Guard Cartridges Brownlee Analytical<br />

Pkg: 3<br />

Length<br />

Particle<br />

Phase mm ID mm Size μm Part No. Each (€)<br />

Amino 10 2.1 5 N9303674 185<br />

Amino 10 4.0 5 N9303675 185<br />

C18 10 2.1 5 N9303676 185<br />

C18 10 4.0 5 N9303677 185<br />

C8 10 2.1 5 N9303678 185<br />

C8 10 4.0 5 N9303679 185<br />

Cyano 10 2.1 5 N9303680 185<br />

Cyano 10 4.0 5 N9303681 185<br />

PAH 10 2.1 5 N9303682 185<br />

PAH 10 4.0 5 N9303683 185<br />

Phenyl 10 2.1 5 N9303684 185<br />

Phenyl 10 4.0 5 N9303685 185<br />

Silica 10 2.1 5 N9303686 185<br />

Silica 10 4.0 5 N9303687 185<br />

Guard Cartridges Brownlee Bio<br />

Pore Size: 300 Å - Pkg: 3<br />

Length<br />

Particle<br />

Phase mm ID mm Size μm Part No. Each (€)<br />

C18 10 2.1 5 N9303708 185<br />

C18 10 4.0 5 N9303707 185<br />

C8 10 2.1 5 N9303709 185<br />

C8 10 4.0 5 N9303710 185<br />

Guard Cartridges Brownlee CHOICE<br />

Pore Size: 60 Å - Pkg: 3<br />

Length<br />

Particle<br />

Phase mm ID mm Size μm Part No. Each (€)<br />

Basix 10 2.1 5 N9303666 185<br />

Basix 10 4.0 5 N9303667 185<br />

C18 10 2.1 5 N9303668 185<br />

C18 10 4.0 5 N9303669 185<br />

Organic Acids 10 2.1 5 N9303670 185<br />

Organic Acids 10 4.0 5 N9303671 185<br />

PFP Propyl 10 2.1 5 N9303672 185<br />

PFP Propyl 10 4.0 5 N9303673 185<br />

Guard Cartridges Brownlee Validated<br />

Pore Size: 100 Å - Pkg: 3<br />

Length<br />

Particle<br />

Phase mm ID mm Size μm Part No. Each (€)<br />

Amino 10 2.1 5 N9303688 185<br />

Amino 10 4.0 5 N9303689 185<br />

Aqueous C18 10 2.1 5 N9303690 185<br />

Aqueous C18 10 4.0 5 N9303691 185<br />

C1 10 4.0 5 N9303722 181<br />

C4 10 4.0 5 N9303723 181<br />

C8 10 2.1 5 N9303695 185<br />

C8 10 4.0 5 N9303696 185<br />

C18 10 2.1 5 N9303693 185<br />

C18 10 4.0 5 N9303694 185<br />

C18 10 4.0 10 N9303692 185<br />

Carbamate 10 2.1 5 N9303697 185<br />

Carbamate 10 4.0 5 N9303698 185<br />

Cyano 10 2.1 5 N9303699 185<br />

Cyano 10 4.0 5 N9303700 185<br />

IBD 10 2.1 5 N9303701 185<br />

IBD 10 4.0 5 N9303702 185<br />

PFP 10 2.1 5 N9303703 185<br />

PFP 10 4.0 5 N9303704 185<br />

Phenyl 10 2.1 5 N9303705 185<br />

Phenyl 10 4.0 5 N9303706 185<br />

Conventional Columns Liquid Chromatography<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

313


Detectors<br />

Diode Array Detector<br />

LC-135C/235 Detector<br />

Series 200 Diode Array Detector<br />

Backpressure Regulator<br />

Adjustable from 15-59 psi,<br />

stainless steel.<br />

Part No. Each (€)<br />

09907126 236<br />

Backpressure Regulator<br />

Adjustable from 15-59 psi,<br />

stainless steel.<br />

Part No. Each (€)<br />

09907126 236<br />

Detector/Lamp<br />

Flowcell Assembly<br />

Part No. Each (€)<br />

N2351285 504<br />

Part No. Each (€)<br />

Detector/Lamps<br />

Description Part No. Each (€)<br />

Deuterium Lamp (Phase 2) N2922046 523<br />

Standard Deuterium Lamp (Phase 1) N2922010 899<br />

Tungsten Source N2922011 143<br />

8.0 μL titanium.<br />

N2350211 1683<br />

Flowcells<br />

Liquid Chromatography Detectors<br />

Operator’s Manual<br />

Maintenance Kit<br />

Includes: test flowcell, D2 lamp,<br />

cell lens, and backpressure valve.<br />

Series 200 Photo Diode Array Detector<br />

Part No. Each (€)<br />

09938727 159<br />

Part No. Each (€)<br />

N2350014 2270<br />

Description Part No. Each (€)<br />

Flowcell Assembly, PEEK N2922029 1492<br />

12 μL, 10 mm path<br />

Low Volume Flowcell Assembly, Stainless Steel N2922030 2168<br />

5.0 μL, 4.5 mm path<br />

Standard Flowcell Assembly, Stainless Steel N2922028 2844<br />

12.0 μL, 10.0 mm path<br />

Operator’s Manual<br />

Part No.<br />

Each (€)<br />

09938914 99<br />

314


Detectors<br />

Fluorescence and Refractive Index (RI) Detector<br />

Series 200 Fluorescence Detector<br />

Combining Sensitivity and Specificity<br />

The Series 200 Fluorescence Detector provides the highest<br />

sensitivities for diverse LC analyses such as serum and<br />

plasma in pharmaceutical research, environmental analysis<br />

of pollutants, and food and beverage products. The major<br />

benefit afforded by fluorescence detection is the inherent<br />

sensitivity of the technique coupled with high specificity.<br />

The Series 200 Detector provides signal-to-noise ratio of<br />

>300:1 for trace analysis using a 150 W Zenon source.<br />

Maximum analysis flexibility is provided by full wavelength<br />

programming (Ex 200-850 nm, Em 250-900 nm), background<br />

subtraction, and spectrum memory.<br />

The major benefit afforded by fluorescence detection<br />

is the inherent high sensitivity of the technique coupled<br />

with outstanding specificity – given that relatively few<br />

molecules natively fluoresce. Therefore, the specific<br />

excitation and emission wavelength profile aids in the<br />

characterization of individual components. The Series 200<br />

Fluorescence Detector delivers the outstanding performance<br />

and reliability you’ve come to expect from PerkinElmer –<br />

backed by our unrivaled global support network.<br />

Series 200 Fluorescence Detector<br />

100/120/220/240 VAC, 50/60 Hz.<br />

Series 200/200A Detector Lamps<br />

Xenon lamp for Series 200 Detector.<br />

Part No.<br />

Each (€)<br />

N2922006 8800<br />

Part No.<br />

Each (€)<br />

N2922082 823<br />

Series 200a Refractive Index Detector<br />

Series 200a RI Detector<br />

The Series 200a Refractive Index (RI) Detector is a highly<br />

stable and sensitive LC and GPC detector. The Series 200a is<br />

well suited for compounds that do not have high absorptivity<br />

in the UV range, such as polymers, sugars, organic acids, and<br />

triglycerides. The full color display and easy keypad entry of<br />

autozero, purge, and thermostatted flow cell temperature,<br />

assure reliable and accurate results every time.<br />

Detector Lamps 200/200a<br />

Components Part No. Each (€)<br />

Series 200 RI Tungsten Source 02712273 332<br />

Manuals/Maintenance Items/Accessories<br />

Components Part No. Each (€)<br />

Series 200 RI Detector Operator’s Manual 09938906 79<br />

Series 200a RI Detector Operator’s Manual 09936751 79<br />

LC-240 FL Detector<br />

Detector Lamps<br />

Components Part No. Each (€)<br />

LC-240 Xenon Source Lamp L2251157 555<br />

Festoon Lamp 04969486 9<br />

Manuals/Maintenance Items/Accessories<br />

Components Part No. Each (€)<br />

LC-240 R928 Photomultiplier 09972337 706<br />

Detectors Liquid Chromatography<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

315


Detectors<br />

UV/Visible Detector<br />

Series 200/785A UV/VIS<br />

Detector Source Lamps<br />

Description Part No. Each (€)<br />

Deuterium Lamp N2920149 510<br />

Tungsten Lamp N2920146 465<br />

Series 200 UV/VIS Detector<br />

Liquid Chromatography Detectors<br />

Series 200 UV/VIS Detector<br />

Outstanding sensitivity.<br />

The proven dual-beam optical design yields high<br />

sensitivity even for difficult ultra-trace analysis,<br />

detecting picogram quantities of many compounds.<br />

Couple that with your choice of either a Deuterium<br />

or Tungsten source for outstanding ultraviolet and<br />

true visible performance anywhere in the detector’s<br />

190-700 nm wavelength range. Lamp changes are<br />

quick and easy due to a unique, self-aligning lamp<br />

mount. Choose from several easily interchangeable<br />

flowcell formats to match your specific analytical<br />

needs – including a flowcell for microbore applications.<br />

Flexibility and ease-of-use are ensured through an<br />

optimized user interface – including an easy-to-read,<br />

multi-line display, tactile keyboard, and context-sensitive<br />

function keys. Full wavelength programmability, batterybacked<br />

method storage, and linking of methods allow for<br />

automated analysis, if required, and method development<br />

activities – all without computer control! A full suite of<br />

user accessible diagnostics allow for quick troubleshooting<br />

in the unlikely event of a problem – while an integrated<br />

leak-detector sounds an audible alert and halts your<br />

analysis if a solvent leak occurs.<br />

When single-point method control of your HPLC system<br />

is required, the Series 200 UV/Vis is fully controllable via<br />

PerkinElmer’s TotalChrom Chromatography Data Systems.<br />

The Series 200 UV/Vis features full digital output of<br />

chromatographic data, so an intermediary analog-to-digital<br />

interface is not required. This simplifies system installation<br />

and operation and reduces bench-space requirements as well.<br />

Deuterium Lamp Part No. N2920149<br />

Series 200/785A UV/VIS<br />

Flowcells/Flowcell<br />

Description Part No. Each (€)<br />

Flowcell Standard N2920117 2134<br />

Analytical (8 mm x 12 μL), for 785A only<br />

Analytical (19 mm x 15 μL), for UV 200 N2920124 546<br />

Flowcell Bulkhead Union 25000323 151<br />

Flowcell Assembly Microbore (6 mm x 2.4 μL) 29000544 2283<br />

Flowcell Assembly Prep (3 mm x 1.7 μL) 29000545 1224<br />

Heat Exchange Assembly, 785A 26000050 1180<br />

Heat Exchange Flowcell Assembly, N2920125 1357<br />

(10 mm x 15 μL), UV 200<br />

Reference Aperture Dry Cell 29000078 37<br />

Windows Flowcell Suprasil (pair) 72000008 146<br />

Series 200/785A UV/VIS<br />

Manuals/Maintenance Items<br />

Description Part No. Each (€)<br />

Backpressure Regulator 09907126 236<br />

Adjustable from 15-59 psi, stainless steel<br />

Cable 785A to TotalChrom 09410036 210<br />

Cable Assembly 60000186 70<br />

Detector Signal, for 785A only<br />

Cable Assembly 60000366 101<br />

Remote Autozero, for 785A only<br />

Series 200 Manual 09936504 106<br />

785A Manual, User’s Manual 09936189 198<br />

316


Ovens<br />

LC Column Ovens<br />

Series 200 Ovens<br />

In many HPLC analyses, variations in column temperature<br />

can cause significant changes in retention times, making<br />

qualitative analysis difficult and affecting the precision of<br />

quantitative measurements.<br />

Series 200 Peltier Column Oven<br />

PerkinElmer offers three versions of the Series 200<br />

Column Oven to meet your specific needs: heat-only,<br />

Peltier (heat and cool) and a Peltier unit with built-in<br />

column selection/switching valve.<br />

The PerkinElmer Series 200 family of column ovens controls<br />

the mobile phase and sample temperature before they enter<br />

the column via a built-in preheater. This eliminates thermal<br />

gradients across the column, resulting in better column<br />

performance and precise retention times. All heating<br />

and cooling (Peltier units only) is performed electrically,<br />

permitting sub-ambient temperatures as low as 5 °C without<br />

coolant or refrigerants.<br />

The Series 200 Oven/Selector permits automated switching<br />

of up to six HPLC columns via PerkinElmer’s TotalChrom<br />

data handling software. This feature is extremely beneficial<br />

for method development applications and in the<br />

multi-user/multi-method labs.<br />

Key Features:<br />

All electronic design permits wide operating range and leak<br />

alarm – Peltier units do not require refrigerants and coolants<br />

Peltier units use remote-control software permitting full<br />

oven and selector valve control in real-time or within<br />

a TotalChrom method sequence<br />

Integrated solvent pre-heater/chiller minimizes<br />

temperature gradients<br />

Large and easily accessible column compartment holds<br />

even 30 cm column formats<br />

Fully stackable design integrates into complete<br />

Series 200 system<br />

Heat Only Oven<br />

Precise temperature control as low as 5 °C above ambient<br />

to 100 °C; accuracy of +/- 1 °C and stability of +/- 0.05 °C<br />

with mobile phase preheating. LED display of set point<br />

and actual temperature. Stackable with other Series 200 LC<br />

modules. Removable front panel<br />

to access column compartment that Part No. Each (€)<br />

accepts up to 30 cm columns.<br />

N2601581 2220<br />

Peltier LC Column Compartment (120 -240 V)<br />

Precise temperature control as low as 7 °C to 90 °C;<br />

accuracy of +/- 1 °C and stability of +/- 0.2 °C with mobile<br />

phase preheating. LED display of set point and actual<br />

temperature. Audible leak alarm. Stackable with other Series<br />

200 LC modules. Removable front panel<br />

to access column compartment that<br />

accepts up to 30 cm columns.<br />

Part No.<br />

N2601580<br />

Each (€)<br />

3089<br />

Peltier Column Compartment and<br />

Selector Valve (120 -240 V)<br />

Precise temperature control from 5 °C to 90 °C; accuracy of<br />

+/- 1 °C and stability of +/- 0.2 °C with mobile phase<br />

preheating. LED display of set point and actual temperature.<br />

Audible leak alarm. Stackable with other Series 200 LC<br />

modules. Removable front panel to access column<br />

compartment that accepts up to 30 cm columns – or<br />

additional smaller column formats. Temperature and<br />

selection valve controlled via software running under<br />

TotalChrom 6.2 or greater. Includes Series 200 Accessory<br />

Control S/W (N2601585). Requires but does not include:<br />

Lantronix terminal (S2000062) or<br />

edge port USB to RS232 (09402020). Part No. Each (€)<br />

Series 200 Accessory Control Software<br />

Software to control heat<br />

only (N2601581) and Peltier<br />

Oven (N2601580).<br />

N2601579 4634<br />

Part No.<br />

Each (€)<br />

N2601585 309<br />

Ovens Liquid Chromatography<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

317


Pumps<br />

Degassing Kits<br />

Degassing Kits - Helium<br />

Helium degassing solvent packages are available in a<br />

choice of three solvent configurations. Each kit contains a<br />

manifold, bottles, and all required tubing and fittings. The<br />

helium manifold has been designed to prevent accidental<br />

over-pressurization and to eliminate the possibility of<br />

solvent migrating back into the helium supply lines. The<br />

glass bottles supplied with the kits are specially coated to<br />

ensure safety and prevent solvent leakage if accidentally<br />

dropped or otherwise broken.<br />

Description Part No. Each (€)<br />

Liquid Chromatography Pumps<br />

The 200 Series Vacuum degasser is a low volume, high<br />

efficiency, on-line module for removal of dissolved gases from<br />

HPLC solvents. The vacuum degasser is available in 3 and 5<br />

channel models to support isocratic, binary and quaternary<br />

pumps as well as degassing of autosampler flush solvent.<br />

Description Part No. Each (€)<br />

3-Channel Vacuum Degassing Package N2600571 1706<br />

Includes: a vacuum degasser, one 1 L bottle<br />

with cap, one 2 L bottle with cap, and an<br />

organizer and tray accessory<br />

5-Channel Vacuum Degassing Package N2600570 3174<br />

Includes: a vacuum degasser, two 1 L bottles<br />

with caps, two 2 L bottles with caps, solvent<br />

tray, and organizer<br />

Replacement Vacuum Degasser Bottles<br />

Description Part No. Each (€)<br />

1 L Glass Bottle N2600497 70<br />

2 L Glass Bottle N2600498 172<br />

Binary Solvent Package N2600505 1100<br />

Includes: one 1 L glass bottle kit and one 2 L<br />

glass bottle kit, with cap assemblies, one helium<br />

manifold, and a solvent organizer accessory<br />

Isocratic Solvent Package N2600491 721<br />

Includes: one 2 L glass bottle kit, with cap<br />

assembly, and a helium manifold<br />

Quaternary Solvent Package N2600506 1643<br />

Includes: two 1 L glass bottle kits and two 2 L<br />

glass bottle kits, with cap assemblies, one helium<br />

manifold, and a solvent organizer accessory<br />

200 Series Vacuum Degasser Kit Part No. N2600571<br />

Degassing System Spares - Helium<br />

200 Series On-line<br />

Vacuum Degasser Kits<br />

Description Size Part No. Each (€)<br />

1 L Glass Bottle N2600497 70<br />

1 L Glass Bottle Kit N2600456 351<br />

Includes: cap assembly, sparger (10 μm), solvent<br />

filter (10 μm), connecting fittings, and instructions<br />

2 L Glass Bottle N2600498 172<br />

2 L Glass Bottle Kit N2600457 414<br />

5 L Glass Bottle N2600499 268<br />

5 L Glass Bottle Kit N2600458 536<br />

Autosampler Flush Bottle Kit N2600459 395<br />

Bottle Cap Assembly N2600495 274<br />

For 1 L and 2 L glass bottles. Includes: sparger<br />

(10 μm), solvent filter (10 μm), connecting fittings<br />

Bottle Cap Assembly N2600496 312<br />

For 5 L glass bottle<br />

Helium Manifold Kit N2600284 459<br />

5 psi regulator<br />

Kel-F Ferrule 1/8 in. 09903771 4<br />

Tefzel Nut 1/8 in. N2601189 11<br />

Supply Connectors - Helium<br />

Each solvent reservoir system requires high-purity helium,<br />

either to pressurize or to degas the solvents. The helium<br />

pressure regulator with shut-off valve can deliver from 5 to<br />

180 psi of pressure from an external tank. We offer all the<br />

fittings needed to connect a helium source to your solvent<br />

reservoir system. Refer to your operator’s manual for<br />

step-by-step installation instructions.<br />

Description Part No. Each (€)<br />

Female Connector 09903906 23<br />

Reduces 1/4 to 1/8 in.<br />

Regulator 00230090 381<br />

5 to 180 psi with outlet shut-off valve<br />

Teflon Tubing 02506483 3<br />

Helium and Solvent Supply, per 1 ft. length<br />

1/8 in. o.d. x .06 in. i.d.<br />

318


Pumps<br />

Piston and Piston Accessories<br />

Check Valves<br />

Check valves, which include a sealing washer, are easy to install using the optional Torque Wrench kit. For all PerkinElmer<br />

pumps an intermediate check valve is required. The input check valve, which is identical, should be ordered.<br />

Standard Micropump Biocompatible<br />

Stainless Steel Stainless Steel Titanium<br />

Description Part No. Each (€) Part No. Each (€) Part No. Each (€)<br />

Inlet/Intermediate Check Valve 02540177 549 02540177 549 N2600226 759<br />

Outlet Check Valve 02540197 549 02540197 549 N2600192 695<br />

Check Valves<br />

Pistons<br />

Series 200 and Model 250/410 Pump Pistons<br />

High and low pressure pistons are made of sapphire for the highest quality hardness and surface.<br />

Standard Micropump Biocompatible<br />

Stainless Steel Stainless Steel Titanium<br />

Description Part No. Each (€) Part No. Each (€) Part No. Each (€)<br />

High Pressure Piston N2600124 344 N2910511 555 N2600124 344<br />

Low Pressure Piston N2600104 255 N2910512 899 N2600104 255<br />

Piston Seals<br />

Series 200 and Model 250/410 Piston Seals<br />

Pistons and Seals<br />

All PerkinElmer pumps contain a high and low pressure piston seal. In addition to the standard high pressure seal, we provide<br />

extended performance seals for more specialized requirements. The chemically resistant seal is composed of a graphite Teflon<br />

material. This seal is inert to an extended range of solvents, such as buffers. It cannot be used with high flows or pressures in<br />

excess of 3000 psi. Whenever replacing the low pressure seal, the Low Pressure Seal Back-Up Ring should also be replaced.<br />

Standard Micropump Biocompatible<br />

Stainless Steel Stainless Steel Titanium<br />

Description Part No. Each (€) Part No. Each (€) Part No. Each (€)<br />

High Pressure Piston Seal Backup O-Ring 09902128 1 09902128 1 09902128 1<br />

High Pressure Piston Seal Backup Ring 02542076 19 02542076 19<br />

High Pressure Piston Seal with Backup Ring 09923367 60<br />

High Pressure Piston Seal – Chemically Resistant (New) 09907345 66<br />

Low Pressure Piston Seal 09907339 60 09923366 40 09907339 60<br />

Low Pressure Piston Seal Backup Guide Bushing 02542313 27 N2601174 98<br />

Standard High Pressure Piston Seal (Gold) 09907324 55 09907338 80<br />

Pumps Liquid Chromatography<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

319


Pumps<br />

Piston and Piston Accessories<br />

Seals, Pistons, and Check Valves<br />

Standard Micropump Biocompatible<br />

Stainless Steel Stainless Steel* Titanium*<br />

Component Part No. Each (€) Part No. Each (€) Part No. Each (€)<br />

Liquid Chromatography Pumps<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

9<br />

Standard High Pressure Piston Seal (Gold) 09907324 55 09907338 80<br />

High Pressure Piston Seal – Chemically Resistant (New) 09907345 66<br />

High Pressure Piston Seal Backup Ring 02542076 19 02542076 19<br />

High Pressure Piston Seal with Backup Ring 09923367 60<br />

High Pressure Piston Seal Backup O-Ring 09902128 1 09902128 1 09902018 1<br />

Low Pressure Piston Seal 09907339 60 09923366 40 09907339 60<br />

Low Pressure Piston Seal Backup Guide Bushing 02542313 27 N2601174 98<br />

High Pressure Piston N2600124 344 N2910511 555 N2600124 344<br />

Low Pressure Piston N2600104 255 N2910512 899 N2600104 255<br />

Inlet/Intermediate Check Valve 02540177 549 02540177 549 N2600226 759<br />

Outlet Check Valve 02540197 549 02540197 549 N2600192 695<br />

* Refer to the User’s Manual for a complete illustrated parts list.<br />

6<br />

9<br />

1<br />

2<br />

3<br />

4<br />

Exploded view of standard stainless steel pump head.<br />

5<br />

7<br />

8<br />

320


Pumps<br />

Pump Accessories<br />

Bio Conversion Kit<br />

Bio Conversion Kit<br />

For the Series 200 Pump and Series 200 Autosampler. Kit<br />

contains all of the parts necessary to<br />

convert the pump and the autosampler<br />

for Bio applications.<br />

Part No.<br />

N2910035<br />

Each (€)<br />

3793<br />

Maintenance Kits and Tools<br />

Description Part No. Each (€)<br />

Biocompatible Piston Seal Replacement Kit N2910385 592<br />

Includes: four seals, backup rings, and O-Rings<br />

Check Valve Torque Wrench 02540871 35<br />

Diaphragm for Pulse Compensator N2601316 140<br />

High Pressure Piston Seal Replacement Kit N2910383 302<br />

Includes: four seals, backup rings, and O-Rings<br />

Insertion Tool N2601503 83<br />

Micropump Piston Seal Replacement Kit N2910384 417<br />

Pulse Compensator Repair Kit N2600313 78<br />

Includes: diaphragm, elastomer plug, and seal<br />

Seal Removal Tool N2601295 7<br />

Series 200 Bio LC Pump Maintenance Kit N2910346 2321<br />

Includes: fuses, seals, O-Rings, and seal tools<br />

Series 200 Pump Maintenance Kit N2910345 931<br />

Includes: fuses, seals, O-Rings, and seal tools<br />

Manuals and Accessories<br />

Description Part No. Each (€)<br />

Model 250 Operator’s Manual 09937169 107<br />

Pump Backpressure Regulator (to generate 02540272 548<br />

backpressure for applications less than 250 psi)<br />

Pump Priming Syringe (30 mL, plastic) 09904849 2<br />

Series 200 Operator’s Manual 09938910 92<br />

Series 200 Pump Injector Bracket N2910349 53<br />

Mixers<br />

Series 200 Dynamic Mixer<br />

Series 200 Dynamic Mixer Accessory (100-240 V) – Used<br />

to facilitate complete mobile phase blending, resulting in<br />

improved retention performance. The mixer will most<br />

typically be used as part of a Series 200 Micro pump<br />

package – where high-pressure blending of 2 pump<br />

outputs is required. Three different volume mixing heads<br />

(75, 200, and 400 μL) are available.<br />

Kit includes: Mixer Accessory, stainless<br />

steel “tee” fitting (N2911127), U.S. style<br />

AC line cord and 0.1 A Type T fuse.<br />

Mixing Heads<br />

Part No.<br />

Each (€)<br />

N2910520 416<br />

Size Part No. Each (€)<br />

75 μL N2910521 349<br />

200 μL N2910522 332<br />

400 μL N2910523 332<br />

Series 200 Dynamic Mixer Mounting Bracket<br />

Allows the mixer to be mounted to<br />

the side of a Series 200 Autosampler<br />

for stacked configurations.<br />

Static Mixers<br />

Static Mixers with high efficient<br />

vortex sheer mixing<br />

Improve gradient accuracy<br />

Increase sensitivity<br />

Reduce baseline noise<br />

In-line binary format<br />

Ideal for microbore HPLC LC/MS<br />

Description Size Part No. Each (€)<br />

Binary T Mixer, Stainless Steel 10 μL N2911170 659<br />

Binary T Mixer, Stainless Steel 150 μL N2911171 659<br />

In-line Mixer Assembly 150 μL N2911173 617<br />

In-line Mixer Assembly 500 μL N2911172 730<br />

Static Mixers Replacement Cartridges<br />

Part No.<br />

Description Size Part No. Each (€)<br />

For 10 μL Binary T Mixer 10 μL N2911174 309<br />

For 10 μL Binary T Mixer 25 μL N2911175 309<br />

For 150 μL Binary T Mixer 50 μL N2911176 309<br />

For 150 μL Binary T Mixer 150 μL N2911177 309<br />

For 150 μL Binary T Mixer 250 μL N2911178 309<br />

Pulse Compensators<br />

The pulse compensator combines high-efficiency pulse<br />

smoothing with a low void volume. A Teflon diaphragm<br />

separates a reservoir filled by an RTV elastomer plug.<br />

Normal use will necessitate the eventual replacement<br />

of the diaphragm.<br />

Each (€)<br />

N2915102 58<br />

Description Part No. Each (€)<br />

Diaphragm for Pulse Compensator N2601316 140<br />

Pulse Compensator Repair Kit N2601313 54<br />

Includes: diaphragm, elastomer plug, and seal<br />

Series 200 Pump Solvent Upgrade Kits<br />

The unique design of the PerkinElmer Series 200 Pump<br />

allows it to easily be upgraded for additional solvent<br />

capability right in your laboratory as your needs change.<br />

Installation of the kit by a PerkinElmer Service and Support<br />

is recommended, but not included. Contact your local<br />

PerkinElmer representative for more information.<br />

Description Part No. Each (€)<br />

Series 200 Binary to Quaternary Upgrade Kit N2910344 4744<br />

Series 200 Isocratic to Binary Upgrade Kit N2910342 4451<br />

Series 200 Isocratic to Quaternary Upgrade Kit N2910343 8400<br />

Pumps Liquid Chromatography<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

321


Pumps<br />

Solvent Filters and Spargers<br />

Solvent Spargers<br />

Solvent Reservoir Sparger<br />

Description Size μm Part No. Each (€)<br />

Stainless Steel 10 09903610 68<br />

Titanium 10 N2600070 65<br />

Stainless Steel 40 09903615 68<br />

Titanium 40 N2600089 75<br />

Solvent Filters<br />

Solvent Sparger<br />

Liquid Chromatography Pumps<br />

Solvent Filters<br />

In-line Solvent Filter System<br />

For stainless steel pumps.<br />

In-line Solvent Filter Replacement Kit<br />

For all stainless steel pumps.<br />

Includes two 0.5 μm filter<br />

elements and four seals.<br />

In-line Solvent Filter System, Titanium<br />

For Biocompatible pumps.<br />

Replacement 2 μm Titanium Filter Element<br />

For in-line solvent filter for Biocompatible pumps. Requires,<br />

but does not include, Replacement Seal<br />

for In-line Solvent Filter (N2601262). Part No. Each (€)<br />

Replacement Seal for In-line Solvent Filter<br />

For Biocompatible pumps. Use with<br />

Replacement 2 μm Titanium Filter<br />

Element (N2601477).<br />

Part No.<br />

Part No.<br />

Each (€)<br />

02540311 68<br />

Part No.<br />

Each (€)<br />

09903606 126<br />

Each (€)<br />

N2600259 631<br />

N2601477 140<br />

Part No.<br />

Each (€)<br />

N2601262 28<br />

322


Supplies and Accessories<br />

Fittings<br />

Fittings<br />

Stainless steel nuts are available in both Parker-Hannifin<br />

and Rheodyne formats. The nuts are used to connect 1/16<br />

in. o.d. stainless steel tubing and feature a 10-32 thread size.<br />

PerkinElmer also offers select SSI fittings for 1/16 in. o.d.<br />

tubing in 1/4-28 thread size.<br />

For biocompatible applications, both plastic and Isopure<br />

titanium fittings are available. PerkinElmer has created a<br />

Biocompatible Column Fittings Kit which contains fittings<br />

of various inert materials, such as PEEK and Tefzel ® .<br />

Description Qty. Part No. Each (€)<br />

Fingertight One-Piece Nut and Ferrule 1 09920513 17<br />

Parker-Hannifin Ferrule, 1/16 in. 1 00873032 15<br />

Parker-Hannifin Nut, 1/16 in. 1 09903980 19<br />

Parker-Hannifin Nut and Ferrule Kit, 1/16 in. 1 00890945 147<br />

Parker-Hannifin Zero-dead-volume Union, 1 09903289 92<br />

with nuts and ferrules<br />

Rheodyne Ferrule, 1/16 in. 1 09904947 10<br />

Rheodyne Nut, 1/16 in.: long body 1 09904974 14<br />

Rheodyne Nut, 1/16 in.: short body 1 09904956 11<br />

Rheodyne Nut and Ferrule Kit, 1/16 in. 1 02540274 92<br />

6 ferrules, 3 short nuts, 3 long nuts<br />

RheoFlex PEEK Nut and Ferrule Set (pkg. 10) 1 N9302676 62<br />

SSI Nut and Ferrule Kit,1/16 in. 1 02540273 68<br />

5 nuts and 10 ferrules<br />

Swagelok Zero-dead-volume Union 1 09903807 106<br />

Titanium Ferrule, 1/16 in. 1 N2601346 17<br />

Titanium Long Nut, 1/16 in. 1 N0911038 73<br />

Titanium Short Nut, 1/16 in. 1 N0911028 31<br />

Tube Nut 410 Bio Pump 1 N2601149 56<br />

Valco Ferrule, 1/16 in. 1 09903891 4<br />

Valco Nut, 1/16 in. 1 09903890 4<br />

Fittings Kits<br />

Biocompatible Column Fittings for LC<br />

Recommended for users of a<br />

PerkinElmer Biocompatible LC system.<br />

Contains nuts, ferrules, and unions.<br />

Fittings Kit for LC<br />

All-in-one fittings kit. The kit contains Rheodyne and SSI<br />

nuts and ferrules as well as Fingertight II nuts and ferrules<br />

for toolless installation. Zero-dead-volume and low-deadvolume<br />

unions are also included. In addition, you receive<br />

varying lengths of stainless steel tubing<br />

in 0.007 and 0.010 in. i.d.s, as well Part No. Each (€)<br />

as 0.030 in. i.d. Tefzel tubing.<br />

N9301002 727<br />

Operation Kit<br />

Recommended for purchasers of their<br />

first LC. Includes tubing, union, fittings,<br />

syringe, basic LC book, and test mix.<br />

PEEK One-Piece<br />

Fingertight TM Fittings<br />

PEEK Union<br />

Part No.<br />

This PEEK Fingertight is the<br />

toughest in regard to chemical<br />

resistance and pressure. This<br />

high-performance fingertight is<br />

recommended for the most<br />

demanding applications and will<br />

resist pressures up to 6000 psi<br />

(400 bar). The diameter of the<br />

head of the nuts has been<br />

increased by 50% to give you<br />

power enough to tighten without<br />

tools. The nut and ferrule are<br />

made from a single piece of<br />

PEEK. (pkg. 10)<br />

Part No.<br />

Each (€)<br />

N9301001 631<br />

Part No.<br />

Each (€)<br />

00890873 721<br />

Each (€)<br />

ED020005 71<br />

The PEEK union allows you to connect two pieces of 1/16 in.<br />

tubing quickly and reliably. This union features a .012 in.<br />

thru-hole of minimum length for the lowest possible dead<br />

volume. Because this is a PEEK union, it is absolutely inert<br />

and biocompatible. The PEEK<br />

union comes without nuts. (pkg. 5)<br />

Part No. Each (€)<br />

ED020008 51<br />

Supplies and Accessories Liquid Chromatography<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

323


Supplies and Accessories<br />

Rheodyne Injection Valves<br />

Rheodyne 7725 Injection Valve<br />

Rheodyne 7010 Injection Valve<br />

Liquid Chromatography Supplies and Accessories<br />

The Model 7725 and 7725i are Rheodyne’s most advanced<br />

sample injectors for analytical HPLC. They can inject from<br />

1 μL to 5 mL with high accuracy and precision. These<br />

versatile injectors can use either of two methods for loading<br />

the sample loop. The partial-filling method uses the syringe<br />

to measure the sample volume. It lets you vary volume<br />

easily without having to change the loop, and it does not<br />

waste any sample. Any amount up to half the loop volume<br />

can be loaded. The amount injected into the column is the<br />

exact volume dispensed from the syringe. The completefilling<br />

method uses the loop to measure the volume. It lets<br />

you load the loop without having to read syringe calibrations<br />

carefully. Excess sample is required to completely flush<br />

mobile phase from the loop. The amount injected is the<br />

volume of the loop.<br />

Flow switching occurs at a flat interface between a<br />

polymeric rotor seal and a ceramic stator face. This<br />

combination provides long seal life. In a clean system,<br />

the 7725 typically can make more than 30,000 injections<br />

before requiring replacement of the rotor seal.<br />

The Models 7725 and 7725i are essentially identical, but<br />

the latter has a built-in position sensing switch, which can<br />

provide the chromatograph with a reproducible start signal.<br />

These models are new versions of the popular Model 7125.<br />

New features include:<br />

Flow is not interrupted during switching, a benefit when<br />

using flow-sensitive detectors, fragile columns, or pumps<br />

that are disturbed by pressure transients. A patented<br />

make-before-break or MBB TM passage makes new<br />

connections before old ones break<br />

Wide port angles provide improved access to fittings<br />

A front-end pressure screw makes it easy to adjust<br />

and maintain<br />

A 2 μL internal sample loop is available. The new models<br />

use the same rotor seals as the 7125, but sample loops and<br />

some other parts are not interchangeable. These injectors are<br />

set for 5000 psi (345 bar, 34 MPa) and are adjustable to 7000<br />

psi (483 bar, 48 MPa). Maximum temperature is 60 °C. A 20 μL<br />

loop is attached when a complete valve is purchased<br />

7725 Injection Valve<br />

For use in the Series 200 Autosampler.<br />

7725i Injection Valve with Internal Switch<br />

For stand-alone use.<br />

Part No.<br />

Part No.<br />

Each (€)<br />

N9306019 1033<br />

Each (€)<br />

N9306017 1090<br />

7010 Injection Valve<br />

The Model 7010 is a single-mode injector for the completefilling<br />

method of loading the sample loop. You can achieve<br />

high precision without the need to read syringe calibrations<br />

carefully. You should load an excess of sample – at least<br />

two loop volumes – to flush mobile phase from the loop.<br />

The 7010 can also be used as a column-switching valve. The<br />

injector ships with a 20 μL loop attached. Pressure is set for<br />

5000 psi and is adjustable to 7000 psi.<br />

Rotor seal is a Vespel polymer, which Part No. Each (€)<br />

has an operating pH range of 0-10. 02540142 785<br />

Rheodyne 8125 Low-Dispersion<br />

Stainless Steel Injection Valve<br />

8125 Injection Valve<br />

Ideal for use in an LC/MS system, the Model 8125 is<br />

designed for 1 mm and 2 mm microbore columns, and<br />

can also be used with conventional analytical columns<br />

(3 to 5 mm). It can inject sample volumes from 0.5 to 50 μL<br />

with zero sample waste, using the partial-filling method.<br />

Small flow passages produce low dispersion, maintaining<br />

the high mass sensitivity inherent in micro columns.<br />

The 8125 Low-dispersion injector can quickly and easily be<br />

added to the PerkinElmer Series 200<br />

Autosampler, thus making it an ideal<br />

choice as a LC/MS sampling accessory.<br />

Part No.<br />

N9306021<br />

Each (€)<br />

1938<br />

Rheodyne 9725 PEEK Injection Valve<br />

The Model 9725 is highly inert and well-suited to the<br />

chromatography of biological molecules using all techniques,<br />

including those with aggressive mobile phases. It applies to<br />

both HPLC and soft gel chromatography, and is also suitable<br />

for ion chromatography, since metal does not contact the<br />

mobile phase. This injector is identical to the Model 7725<br />

stainless steel injector, but the materials are different: the<br />

loop, nuts, ferrules, stator, and vent lines are made of PEEK,<br />

polyetheretherketone; the rotor seal polymer is Tefzel. PEEK<br />

has an outstanding combination of strength and inertness.<br />

The operating pH range is 0 to 14. The injector is set for its<br />

maximum pressure capability, 5000 psi (345 bar, 34 MPa).<br />

However, useable pressure may be lower, since the burst<br />

pressure of the PEEK sample loop usually limits it.<br />

Maximum temperature is 50 °C. A 20 μL loop is attached.<br />

The Rheodyne 9725 can quickly and easily be added to<br />

the PerkinElmer Series 200 Autosampler, making it an<br />

ideal sampling accessory for biochemistries. The Series<br />

200 Autosampler also supports Peltier-cooled sample<br />

trays for temperature labile samples (see page 270).<br />

9725 Injection Valve<br />

For use in the Series 200 Autosampler.<br />

Part No.<br />

Each (€)<br />

N9306020 1530<br />

324


Supplies and Accessories<br />

Rheodyne Injection Valves<br />

Rheodyne Valves Spare Parts<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

9<br />

10<br />

11<br />

12<br />

13<br />

14<br />

15<br />

16<br />

17<br />

18<br />

Model 9725 Model 8125 Model 7010 Model 7125 Model 7725<br />

Part Part No. Each (€) Part No. Each (€) Part No. Each (€) Part No. Each (€) Part No. Each (€)<br />

Handle Screw<br />

Handle<br />

Knob Assembly<br />

Set Screws<br />

Needle Guide<br />

S200 Autosampler N2931054 51 N2931054 51 N2931054 51<br />

Manual Valve 09904800 28 09904800 28 09904800 28 09904800 28<br />

ISS-100 02541946 47<br />

Body<br />

Thrust Bearing<br />

Rotor Pin<br />

Seal Pins<br />

Needle Port Tube 09904805 40 09904805 40 09904805 40 09904805 40<br />

Bearing Ring 09904963 47 09904963 47<br />

Isolation Seal 09904962 85 09904962 85<br />

Rotor Seal<br />

Vespel 09904802 98 10070900 125 09904955 94 09904802 98 09904802 98<br />

Tefzel N9302677 103 N9302677 103 N9302677 103<br />

PEEK N9306044 105 N9306044 105 N9306044 105<br />

Stator Ring<br />

Stator Face Assembly 09904801 347<br />

PEEK and Ceramic N9306047 179 N9306047 179<br />

Set Screws<br />

Stator 10071000 1849 09904953 293<br />

PEEK N9306046 338<br />

Stainless Steel 09904953 293 N9306045 402<br />

Titanium N0911041 740<br />

Stator Screws<br />

1 2<br />

7<br />

10<br />

3<br />

4<br />

5<br />

6<br />

8<br />

9<br />

11<br />

12<br />

13<br />

14<br />

15<br />

16<br />

17<br />

18<br />

Rheodyne Injection Valve<br />

Supplies and Accessories Liquid Chromatography<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

325


Supplies and Accessories<br />

Rheodyne Sample Loops<br />

Internal Loop for<br />

Models 7725/9725<br />

PEEK Sample Loops<br />

for Rheodyne Valves<br />

Liquid Chromatography Supplies and Accessories<br />

Description Part No. Each (€)<br />

2 μL (PEEK and Ceramic) N9306022 230<br />

Sample Loops<br />

Stainless Steel Sample Loops for Rheodyne Valves and Injectors<br />

PEEK Sample Loops avoid many of the problems associated<br />

with stainless steel sample loops. Metal loops will often<br />

absorb sample components resulting in inaccurate quantitative<br />

results. In addition, metal loops may be corroded by<br />

high-salt buffers and chloride salts. Sample Loops are<br />

made from PEEK tubing and fittings. PEEK (Poly-Ether-<br />

Ether-Ketone) is a mechanically strong, chemically inert<br />

polymer ideal for HPLC applications where metal surfaces<br />

may interact with mobile phase or sample components.<br />

Each Sample Loop is supplied with two PEEK hex-head<br />

nuts and ferrules. These fittings grip the tubing in two<br />

locations for a more reliable connection.<br />

Model 9725<br />

Description Part No. Each (€)<br />

5 μL PEEK Sample Loop N9306033 125<br />

10 μL PEEK Sample Loop N9306034 125<br />

20 μL PEEK Sample Loop N9306035 125<br />

50 μL PEEK Sample Loop N9306036 125<br />

100 μL PEEK Sample Loop N9306037 125<br />

200 μL PEEK Sample Loop N9306038 140<br />

500 μL PEEK Sample Loop N9306039 185<br />

1 mL PEEK Sample Loop N9306040 140<br />

2 mL PEEK Sample Loop N9306041 210<br />

5 mL PEEK Sample Loop N9306042 351<br />

Model 7125/7010 Model 7725 Model 8125<br />

Description Part No. Each (€) Part No. Each (€) Part No. Each (€)<br />

5 μL Stainless Steel Sample Loop 09904827 61 N9306023 83 20143300 125<br />

10 μL Stainless Steel Sample Loop 09904938 59 N9306024 83<br />

20 μL Stainless Steel Sample Loop 09904939 59 N9306025 83 10082600 78<br />

50 μL Stainless Steel Sample Loop 09904940 59 N9306026 83<br />

100 μL Stainless Steel Sample Loop 09904942 65 N9306027 83 41000013 78<br />

200 μL Stainless Steel Sample Loop 09904818 61 N9306028 83 09904818 61<br />

500 μL Stainless Steel Sample Loop 09904819 68 N9306029 83<br />

1 mL Stainless Steel Sample Loop 09904820 75 N9306030 83<br />

2 mL Stainless Steel Sample Loop N9306031 172<br />

5 mL Stainless Steel Sample Loop N9306032 210<br />

Note: Loops are compatible with both manual valves and Series 200 Autosampler valves.<br />

326


Supplies and Accessories<br />

Sample Introduction<br />

Microsyringes (For Manual Injection)<br />

Syringes are used for accurate and precise liquid delivery.<br />

Each syringe is hand-fitted to assure maximum accuracy.<br />

Our syringes are composed of glass barrels and precision<br />

stainless steel needles. The needle features a blunt tip,<br />

required for use with a Rheodyne injector.<br />

Description Part No. Each (€)<br />

10 μL Syringe 09904937 59<br />

25 μL Syringe 09904823 52<br />

50 μL Syringe 09904941 60<br />

100 μL Syringe 09904822 62<br />

Rheodyne 22-gauge Blunt Needle with Luer Hub 09904943 34<br />

PEEK Tubing<br />

PEEK tubing has the strength required to withstand continuous<br />

use at HPLC pressure without swelling or bursting. The<br />

dense polymer structure of PEEK tubing eliminates the<br />

permeability to organic solvents that causes other polymer<br />

tubing, such as Tefzel ® to “sweat.”<br />

Use PEEK tubing with virtually any organic or inorganic<br />

liquid. PEEK tubing is not affected by halide salts, high<br />

strength buffers or other aggressive mobile phases that<br />

degrade stainless steel.<br />

Description Size Part No. Each (€)<br />

1/16 in. o.d. x .007 in. i.d. 5 ft. N9302678 40<br />

1/16 in. o.d. x .010 in. i.d. 5 ft. N9302650 34<br />

Solvent and Sample Filtration<br />

All-Glass Filter Apparatus<br />

For solvent filtration.<br />

FP Vericel Hydrophilic Filters<br />

For aqueous mobile phase,<br />

47 mm, 0.45 μm. (pkg. 100)<br />

PTFE Hydrophobic Filters<br />

For nonaqueous mobile phase,<br />

47 mm, 0.45 μm. (pkg. 100)<br />

Sample Filter Assembly<br />

Acro LC-13 13 mm, 0.45 μm,<br />

for common reversed-phase<br />

solvents. (pkg. 100)<br />

Sample Filter Assembly<br />

Acrodisk CR-13 13 mm, 0.45 μm,<br />

for THF, DMSO, etc. (pkg. 100)<br />

Part No.<br />

Each (€)<br />

N9301063 867<br />

Part No.<br />

Each (€)<br />

N9301067 230<br />

Part No.<br />

Each (€)<br />

N9301068 593<br />

Part No.<br />

Each (€)<br />

02542783 370<br />

Part No.<br />

Each (€)<br />

02542782 351<br />

Tubing and Connectors<br />

Stainless Steel Tubing<br />

SS-316 Tubing<br />

Description Size Part No. Each (€)<br />

1/16 in. o.d. x .043 in. i.d. 6 ft. 00873035 77<br />

1/16 in. o.d. x .015 in. i.d. 6 ft. 00873036 66<br />

1/16 in. o.d. x .007 in. i.d. 3 ft. 02540838 140<br />

1/16 in. o.d. x .007 in. i.d. 20 cm 02711441 9<br />

1/16 in. o.d. x .007 in. i.d. 50 cm 00891480 37<br />

Tefzel Tubing<br />

Description Size Part No. Each (€)<br />

1/16 in. o.d. x .030 in. i.d. 10 ft. N9301029 64<br />

Tubing Accessories<br />

For cutting polymeric tubing.<br />

Clean-Cut TM Tubing<br />

The Clean-Cut is designed to cut Teflon ® , Tefzel, and<br />

polymers in general, and PEEK capillary tubing in particular.<br />

The compact design enables every chromatographer to carry<br />

it in his pocket. A unique safety locking mechanism secures<br />

the blade when not in use.<br />

Suitable for dimensions from<br />

Part No. Each (€)<br />

1/16 to 1/8 in. (pkg. 1)<br />

ED020015 18<br />

Replacement Blade<br />

(pkg. 10)<br />

Tubing Plier<br />

Part No.<br />

Each (€)<br />

ED020016 13<br />

For cutting 1/16 in. stainless steel capillaries. Annealed<br />

jaws with plastic handles.<br />

Avoids distortion of o.d.<br />

and closing the i.d. (pkg. 1)<br />

Part No.<br />

ED020017<br />

Each (€)<br />

33<br />

Supplies and Accessories Liquid Chromatography<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

327


TotalChrom CDS<br />

Software<br />

TotalChrom TM<br />

Chromatography Data Systems<br />

A proven solution with leading edge productivity.<br />

The TotalChrom Client/Server (TC C/S) Data System is the<br />

solution in multi-user environments. TC C/S systems can<br />

easily integrate all existing chromatographs into a single<br />

networked system supporting an unlimited number of<br />

users and an unlimited number of chromatographs.<br />

TotalChrom features TC Publisher, a powerful application<br />

that extends report capabilities beyond the standard<br />

templates by providing a sophisticated laboratory report<br />

generator using standardized tools. Unique features let<br />

you graphically format the exact report as needed without<br />

extensive training or special commands. It ensures that<br />

the stages of chromatographic analysis, report generation,<br />

and distribution are quick, easy, and complete.<br />

Report templates can perform calculations between different<br />

peaks in the same sample or even between samples, as well<br />

as automate statistical determination to replicate injections,<br />

with full control over the output format.<br />

Streamlining your laboratory workflow,<br />

the entire process from setting up an<br />

analytical method to the final approval<br />

of reports is a streamlined series of<br />

operations in TotalChrom<br />

PerkinElmer’s TotalChrom Chromatography Data System<br />

(CDS) is designed to provide laboratories with the total<br />

answer to chromatography data handling needs.<br />

Acquiring, processing, reporting, reviewing and approving<br />

data is a streamlined series of operations in PerkinElmer’s<br />

TotalChrom Chromatography Data System, software<br />

designed to fit your laboratory workflow and maximize<br />

productivity. With its scalable architecture, 21 CFR part<br />

11 compliance features and proven algorithms,<br />

TotalChrom offers a computing strategy to manage your<br />

chromatography data quickly and securely in both<br />

regulated and non-regulated environments.<br />

Quickly and Easily Navigate,<br />

Review and Approve Your Data<br />

In the “paper world” reports need to be reviewed and<br />

signed. The TotalChrom Review & Approve (R&A) feature<br />

is a Graphical Reviewing environment that allows intuitive<br />

navigation into data and reports, and provides for the<br />

implementation of a data approval cycle. With TC R&A,<br />

chromatograms, raw data results, and reports can be easily<br />

viewed and compared at a glance.<br />

Reviewing and approving reports can be done electronically,<br />

with multiple levels of authority and secure electronic<br />

signatures. High throughput applications have dramatically<br />

increased the amount of information produced every<br />

day in a laboratory. This feature streamlines tedious data<br />

review by using one single environment to navigate into<br />

data, just like we, every day, navigate into e-mail.<br />

When configured with a PerkinElmer Clarus 500 Gas<br />

Chromatograph or a PerkinElmer Series 200 Liquid<br />

Chromatograph, the TotalChrom Data System is the<br />

controller and data manager for the overall system.<br />

TotalChrom systems can also control selected instruments<br />

from other vendors and can acquire data from any<br />

chromatographic system through A/D interface.<br />

328 www.perkinelmer.com/<strong>supplies</strong>


Software<br />

Intelligent Interfaces for TotalChrom<br />

TotalChrom systems utilize PerkinElmer Intelligent<br />

Interfaces to connect each chromatography system to the<br />

data system PC. Each interface contains buffered RAM<br />

memory to maintain data collection in the event that the PC<br />

or PC network becomes inoperative during data acquisition.<br />

Data from instruments is never lost and chromatograph<br />

productivity is preserved.<br />

Analog chromatographs connect to TotalChrom through<br />

NCI (Network Chromatography Interface) Series Intelligent<br />

Interfaces. The model NCI 901 is a single-channel device,<br />

while the model NCI 902 is a dual-channel device. Both<br />

interface models are capable of taking analog detector data<br />

(unipolar or bipolar) at sampling rates from 0.1 to 100 Hz.<br />

dotLINK<br />

dotLINK–interfacing with ease<br />

dotLINK is a Windows CE-based interface that allows you<br />

to connect your Clarus 500 GC and Series 200 HPLC, plus<br />

Agilent 1100 and Agilent 6890 GCs directly to the network.<br />

Designed to face today’s workload challenges and provide<br />

Ethernet connectivity, dotLINK allows external buffering<br />

with a minimal need for validation. The dotLINK box has a<br />

small footprint providing valuable space for your laboratory.<br />

dotLINK supports the following GC and HPLC configurations:<br />

Maximum of 3 PKI Clarus 500 GCs<br />

Maximum of 1 PerkinElmer Series 200 HPLC System Stack<br />

Maximum of 2 Agilent 6890 GCs<br />

Maximum of 1 Agilent 1100 HPLC/UV System Stack<br />

NCI Intelligent Interfaces<br />

NCI Series Intelligent Interfaces are 24-bit, either single or<br />

dual-channel, buffered, A/D converters which have softwareselectable<br />

input voltage ranges of 10, 2, 1, and 0.1 V with<br />

6-decade dynamic range, programmable sampling rates<br />

from 0.1 to 100 points per second selectable in TotalChrom<br />

software, less than 1 microvolt noise (peak to peak), 0.1%<br />

linearity, three sense input lines, and one system READY<br />

relay for communication with Autosamplers. Includes a<br />

board containing seven programmable relays and a Rack/<br />

Vial Port (TTL voltage levels) for reading Autosampler vial<br />

BCD information. Memory is segmentable for multiple<br />

chromatograms. Software selectable symmetric bipolar or<br />

unipolar mode operation. All Interfaces carry a one-year<br />

return to Service Depot warranty.<br />

Model NCI 901 Intelligent Interface<br />

with RVP/Relay Board, 120 V<br />

Single channel A/D with 256 KB RAM memory<br />

and RVP/Relay board. Stores up to 120 K data points.<br />

Unipolar/bipolar operation modes. Requires, but<br />

does not include, one IEEE or RS232 interface cable.<br />

Includes 120 V power cord.<br />

Part No. Each (€)<br />

S9000070<br />

Model NCI 901 Intelligent Interface<br />

with RVP/Relay Board, 240 V<br />

Single channel A/D with 256 KB RAM memory<br />

and RVP/Relay board. Stores up to 120 K data points.<br />

Unipolar/bipolar operation modes. Requires, but<br />

does not include, one IEEE or RS232 interface cable.<br />

Includes 240 V power cord.<br />

Part No. Each (€)<br />

Model 902 Intelligent Interface<br />

with RVP/Relay Board, 120 V<br />

Model 902 Intelligent Interface<br />

with RVP/Relay Board, 240 V<br />

S9000075 2671<br />

Dual channel A/D with 256 KB RAM memory<br />

and RVP/Relay board. Stores up to 120 K data points.<br />

Unipolar/bipolar operation modes. Requires, but<br />

does not include, one IEEE or RS232 interface cable.<br />

Includes 120 V power cord.<br />

Part No. Each (€)<br />

S9000090<br />

Dual channel A/D with 256 KB RAM memory<br />

and RVP/Relay board. Stores up to 120 K data points.<br />

Unipolar/bipolar operation modes. Requires, but<br />

does not include, one IEEE or RS232 interface cable.<br />

Includes 240 V power cord.<br />

Part No. Each (€)<br />

S9000095 4010<br />

Software Liquid Chromatography<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

329


Software<br />

Interface Modules for TotalChrom<br />

Interface Personality Modules (IPM)<br />

Interface Validation Modules (IVM)<br />

Liquid Chromatography Software<br />

IPMs are instrument-specific software programs that<br />

interpret and translate instrument control and data<br />

acquisition parameters between TotalChrom and a specific<br />

digital instrument. IPMs are downloaded from the host PC<br />

(TotalChrom) by a configuration function to a specific<br />

(Serial or Ethernet) port on a dotLINK interface (internal<br />

or external). Downloaded IPMs are stored in nonvolatile<br />

memory in the dotLINK interface.<br />

IPM for Agilent 1100 HPLC<br />

Provides control for the Agilent series 1100 HPLC modules.<br />

Each dotLINK Interface or M610 can accommodate one<br />

HPLC instrument system. Requires, but does not include,<br />

serial communication cable for each Agilent 1100 module<br />

controlled by TotalChrom.<br />

Description Part No. Each (€)<br />

TotalChrom Client Server N5150267 494<br />

TotalChrom Workstation N5150167 494<br />

IPM for PerkinElmer LC Systems<br />

Provides complete control of PerkinElmer HPLC pumps,<br />

random access autosampler, diode array detectors (S200<br />

and LC-235C), and programmable UV/Vis detectors (S200<br />

and LC-785A)* with simultaneous digital data acquisition<br />

from two channels per detector. This IPM may be configured<br />

across one or more dotLINK or 600 Series LINK interface(s)<br />

on a single TotalChrom acquisition system. Each dotLINK<br />

interface can accommodate one HPLC instrument system.<br />

Requires, but does not include, one Turbo LC Plus<br />

Communications Kit for each LC module controlled by<br />

TotalChrom Workstation. Also compatible with TurboChrom<br />

Workstation v6 data systems.<br />

Description Part No. Each (€)<br />

TotalChrom Client Server N5150262 494<br />

TotalChrom Workstation N5150162 494<br />

* Series 200 UV/Vis detector requires TotalChrom<br />

or TurboChrom Workstation v6.1.2 or higher.<br />

Model 520 Interface Validation Module, 120 V<br />

The Model 520 IVM is a calibrated analog peak pattern<br />

generator for use in testing/validating analog to digital<br />

converters such as the NCI 901/902 and the Series<br />

900/900A Intelligent Interfaces. The module generates<br />

eight possible analog patterns at selectable voltage ranges<br />

of 0-0.1, 0-1, 0-2, and 0-10 V. Factory calibration is traceable<br />

to a NIST standard volt. Includes remote start/stop cable<br />

and analog signal cable for connection to PerkinElmer<br />

NCI/900/900A Series Intelligent Interfaces. Includes<br />

one-year return to Service Depot warranty.<br />

Voltage Part No. Each (€)<br />

120 V S9000160<br />

240 V S9000165 2586<br />

TotalChrom Workstation Model 520 IVM Software<br />

Allows user to test any NCI Series and M900A Series<br />

Intelligent Interfaces to validate interface operations<br />

(linearity, reproducibility, etc.). Contains special<br />

TotalChrom interface test methods and automated<br />

validation logs to maintain results of interface tests<br />

in software. Requires, but does not include, a Model 520<br />

Interface Validation Module.<br />

Part No. Each (€)<br />

Power Cords – 240 V<br />

N5150181 314<br />

Select appropriate power cord (No Charge) from list below. All 120 V<br />

interfaces include USA power cord. Canada, Japan, Taiwan, Puerto Rico,<br />

Bahamas, and most Latin American countries use 120 V interface version.<br />

Country Part No. Each (€)<br />

Australia, New Zealand 09991417 23<br />

Denmark, Greenland 09991416 27<br />

Europe, Saudi Arabia, Egypt, South Africa, 09991415 30<br />

India, Thailand, China<br />

Switzerland, Liechtenstein 09991413 25<br />

UK, Cyprus, Nigeria, Zimbabwe, 09991414 41<br />

Singapore, Malaysia, Zambia<br />

330


Software<br />

Serial Cables<br />

IEEE Cables<br />

All TC Versions<br />

Serial Cables<br />

Serial Cables for Instrument to dotLINK<br />

Cable Length Part No. Each (€)<br />

1 m 65105001 153<br />

2 m 65105102 173<br />

4 m 65105204 184<br />

8 m 65105408 230<br />

Connector Extender<br />

Extender attachment for use on computers where the PC<br />

case interferes with connection of the<br />

IEEE cable. Attaches to the IEEE board<br />

connector on back of PC case.<br />

Part No.<br />

09997196<br />

Each (€)<br />

73<br />

Serial Cables to Lantronix<br />

Terminal Server from<br />

TotalChrom Interfaces<br />

For M950/970 Interfaces<br />

7 ft. S5010017 32<br />

25 ft. S5010018 38<br />

50 ft. S5010019 51<br />

100 ft. S5010020 64<br />

For M941/M600 LINK Interfaces<br />

7 ft. S5010021 32<br />

25 ft. S5010022 38<br />

50 ft. S5010023 51<br />

100 ft. S5010024 64<br />

For NCI Interfaces<br />

7 ft. S5010037 63<br />

25 ft. S5010038 71<br />

50 ft. S5010039 64<br />

100 ft. S5010040 77<br />

Serial Cables to PC from<br />

TotalChrom Interfaces<br />

For M941 A and M600/610 Link Interfaces<br />

7 ft. S5010025 46<br />

25 ft. S5010030 52<br />

50 ft. S5010031 64<br />

100 ft. S5010032 77<br />

For dotLINK Interfaces<br />

10 ft. 09290144 19<br />

25 ft. 09290145 47<br />

For NCI Interfaces<br />

7 ft. S5010033 46<br />

25 ft. S5010034 52<br />

50 ft. S5010035 64<br />

100 ft. S5010036 77<br />

Description Part No. Each (€)<br />

Agilent 1100 HPLC to dotLINK, 10 ft. 09290144 19<br />

NCI Series to dotLINK S5010037 63<br />

for non-controlled detectors, 7 ft.<br />

PerkinElmer Series 200 Autosampler 09290149 9<br />

to dotLINK, 5 ft.<br />

PerkinElmer Series 200 Pump to dotLINK, 5 ft. 09290148 8<br />

PerkinElmer Series 200 UV/Vis to dotLINK, 5 ft. 09290149 9<br />

Serial Cables* for Instrument to M600 LINK<br />

Description Part No. Each (€)<br />

Agilent 1100 HPLC to M600/M610 LINK, 10 ft. S5010015 223<br />

Agilent 1100 HPLC to M600/M610 LINK, 25 ft. S5010016 300<br />

M900/960/970 Series Interface S5010013 223<br />

to M600/M610 LINK, 6 ft. (not for M941)<br />

NCI Series Interface to M600/M610 LINK, 6 ft. S5010041 223<br />

PerkinElmer ISS 200 Autosampler 09410015 159<br />

to M610 LINK, 6 ft.<br />

PerkinElmer Series 200 Autosampler N2930343 198<br />

to M610 LINK, 6 ft.<br />

PerkinElmer Model 250 Pump, Series 410 Pump 09410015 159<br />

to M610 LINK, 6 ft.<br />

PerkinElmer LC 235C Diode Array Detector 09410015 159<br />

to M610 LINK, 6 ft.<br />

PerkinElmer Series 200 Pump to M610 LINK, 6 ft. 09410020 187<br />

PerkinElmer Model 785A UV/Vis Detector 09410036 210<br />

to M610 LINK, 6 ft.<br />

PerkinElmer Series 200 UV/Vis Detector N2930343 198<br />

to M610 LINK, 6 ft.<br />

* Special serial cards, instrument communication kits, and IPM software<br />

may be required to complete interfacing of a LINK interface to a digital<br />

chromatograph. Please contact your local PerkinElmer Sales<br />

Representative for details.<br />

Software Liquid Chromatography<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

331


Software<br />

TotalChrom Software Kits<br />

Liquid Chromatography Software<br />

TotalChrom Optional Software<br />

Size Exclusion Software (TurboSEC)<br />

for TotalChrom Workstation<br />

TurboSEC provides calculation and reporting of weight<br />

average (Mw) or number average (Mn) molecular weight<br />

distributions. PolyDispersivity (Mw/Mn), z-average,<br />

viscosity average (Mv) and Intrinsic Viscosity. Slice reports,<br />

peak reports and Above/Below reports are also available.<br />

Plot options include SEC chromatograms, calibration plots,<br />

and overlays of cumulative Mw%, Mn%, Mz% averages on<br />

plots. Includes calibration using narrow or broad molecular<br />

weight standards with plots of log Mw vs. retention time of<br />

volume, nine calibration curve fit types, universal (integral)<br />

calibration, and retention time shift marker peak. User<br />

may draw baselines and processing limits are settable<br />

interactively through graphics.<br />

Requires TotalChrom or TurboChrom Part No. Each (€)<br />

Workstation v6.1 or higher.<br />

N5150183 1995<br />

Turbo Method Development Software<br />

for TotalChrom Workstation<br />

Turbo Method Development Software provides full binary,<br />

ternary, and quaternary mobile phase optimization by<br />

automatically searching mobile phase variables. Graphical<br />

displays of separation results indicate optimized area of<br />

separation. Also includes ruggedness testing with complete<br />

automation and documentation.<br />

Requires TotalChrom Workstation Part No. Each (€)<br />

v6.2 or higher software.<br />

N5150187 1596<br />

IRIS Spectral Processing Software<br />

for TotalChrom<br />

IRIS is an optional software program for spectral processing<br />

of data acquired from the PerkinElmer S200 Diode Array<br />

Detectors. Requires IPM for PerkinElmer LC Modules<br />

(N5150162) for control of S200. Also requires TotalChrom<br />

or TurboChrom 6.3.1 or higher.<br />

Part No. Each (€)<br />

TurboScan 200<br />

N5150130 1877<br />

TurboScan 200 is an optional software program for spectral<br />

processing of data aquired from the LC 235C PDA detector.<br />

Requires TurboChrom 6.1.x,<br />

TotalChrom 6.2.x or 6.3.0.<br />

Part No. Each (€)<br />

S2700055 2137<br />

TotalChrom Workstation Manuals<br />

Application Manager’s Guide<br />

Application Manager’s Guide covering<br />

installation and system management<br />

of TotalChrom Workstation software.<br />

Manual Set<br />

Complete manual set including User’s<br />

Guide (volumes 1 and 2), Application<br />

Manager’s Guide, and Tutorial.<br />

TotalChrom Tutorial<br />

Software tutorial that teaches basic data acquisition, method<br />

development, optimization techniques,<br />

sequence development, and calibration.<br />

Part No. Each (€)<br />

N5156021 70<br />

User’s Guide (Volumes 1 and 2)<br />

User’s Manual covering instrument<br />

configuration and basic operation<br />

of TotalChrom Workstation software.<br />

TotalChrom Workstation<br />

SI/DI Upgrade Kits<br />

TurboChrom Workstation Migration<br />

to TotalChrom v6.3.x Workstation<br />

Part No.<br />

Each (€)<br />

N5156025 128<br />

Part No.<br />

Each (€)<br />

N5150512 383<br />

Part No.<br />

Each (€)<br />

N5150518 255<br />

Migrates an existing TurboChrom Workstation v4.x 02 or<br />

v6.1.x acquisition system, and associated RPO systems, to<br />

TotalChrom Workstation v6.3.x software. Requires<br />

verification of ownership of<br />

TurboChrom software. Software<br />

supplied with CD-ROM media.<br />

Part No.<br />

N5150349<br />

Each (€)<br />

1140<br />

v6.2.x Workstation Migration to v6.3.x Workstation<br />

Migrates an existing TotalChrom v6.2.x acquisition system,<br />

and associated RPO Systems, to TotalChrom Workstation<br />

v6.3.x software. Requires verification of ownership of<br />

TotalChrom v6.2.x software. Software<br />

supplied with CD-ROM media.<br />

Part No. Each (€)<br />

N5150715 855<br />

332


PerkinElmer is the leader in<br />

high-sensitivity Thermal Analysis<br />

instrumentation, providing you the<br />

confidence to achieve fast, accurate,<br />

reproducible results. Our industryleading<br />

Thermal Analysis Pyris<br />

software and extensive range of<br />

Thermal Analysis accessories combine<br />

ease of use with needed flexibility,<br />

delivering solutions for a vast array of<br />

material property analyses.<br />

Thermal Analysis<br />

HyperDSC is the only true fastscan DSC<br />

technique, featuring scanning rates of up to<br />

500 °C/minute, giving you the ability to achieve fast,<br />

accurate, reproducible results. The technique is only<br />

available on the Diamond DSC from PerkinElmer and is<br />

used in many of the world’s leading pharmaceutical and<br />

polymer R&D laboratories because of its ability to provide<br />

information that previously may have gone undetected.


Thermal Analysis<br />

QUICK-FIND INDEX Page #<br />

DSC Autosampler Supplies<br />

and Accessories 345<br />

DSC High Pressure Cell<br />

and Supplies 346<br />

DSC Intracoolers and<br />

Subambient Accessories 347<br />

DSC Photocalorimeter<br />

Accessories and Supplies 349<br />

DSC Sample Holder Supplies 350<br />

DSC Sample Pan Crimpers 344<br />

DSC Sample Pans<br />

Quick Reference 336<br />

DTA Supplies and Accessories 353<br />

Laboratory Products<br />

and Accessories 354<br />

Mechanical Analysis:<br />

DMA Measuring Systems 356<br />

PerkinElmer offers a wide selection of superior quality products designed to work with<br />

your PerkinElmer instruments. Our precision-designed products deliver the peace of<br />

mind that comes from knowing that you’ll get the results you need.<br />

The Quick Find Index to the left will help you find products fast. For your convenience,<br />

products are alphabetized by category, sub-category, and family. There is also a more<br />

complete Alphabetical INDEX on page 429 and a Part Number INDEX on page 407.<br />

Aluminum Sample Pans and Covers<br />

Autosampler Sample Pans and Covers<br />

Used with nonvolatile solid samples, such as polymers<br />

and pharmaceuticals. Routinely used for applications such<br />

as polymer melting, crystallization, glass transitions of<br />

polymers, thermoplastics, and thermosets. Pans are<br />

crimped, but not hermetically sealed.<br />

Page 336<br />

The autosampler pans are available in sealed or<br />

vented versions. These pans may also be used for<br />

non-robotic systems.<br />

Page 338<br />

Mechanical Analysis:<br />

DMA/TMA Furnace Accessories 366<br />

Mechanical Analysis:<br />

TMA Measuring Systems 364<br />

Purge Gas Accessories 354<br />

TG/DTA Supplies<br />

and Accessories 367<br />

TGA Furnace and<br />

Furnace Accessories 369<br />

TGA Hangdown Wires,<br />

Sample Pans, and Supplies 371<br />

Thermal Analysis Software 373<br />

Ultramicrobalance Supplies 375<br />

Thermal Analysis Gas Station<br />

Universal Crimper Press<br />

The Thermal Analysis Gas Station provides full control<br />

of all gases used in thermal analysis. In addition to<br />

performing gas switching, it also fully controls the gas<br />

flow rate, and detects rapid changes in pressure and empty<br />

cylinders. The Thermal Analysis Gas Station controls up<br />

to four purge gases, uses calibrated massflow controls,<br />

and is easy to program.<br />

Page 355<br />

The Universal Crimper Press provides high quality pan<br />

sealing for the autosampler sample pans/hermetically<br />

sealed pans and can also crimp standard aluminum pans,<br />

large volume stainless steel (24 bar), and volatile pans.<br />

This is achieved simply by using the appropriate sealing<br />

insert. Includes sample pan suction tool and inserts to<br />

seal 10, 30, and 50 μL sample pans.<br />

Page 344


Differential Scanning Calorimeter (DSC)<br />

Thermal Analysis<br />

PerkinElmer is the leader in high sensitivity Thermal<br />

Analysis instrumentation, providing you the confidence to<br />

achieve fast, accurate, reproducible results. Our industryleading<br />

Thermal Analysis software and extensive range<br />

of Thermal Analysis accessories combine ease of use<br />

with needed flexibility, delivering solutions for a vast array<br />

of material property analyses. In addition to our power<br />

compensation Diamond DSC, PerkinElmer offers traditional<br />

heat flux DSC’s for less demanding applications.<br />

Diamond DSC<br />

The Diamond DSC is PerkinElmer’s unique powercompensation<br />

DSC, offering unparalleled sensitivity and<br />

insights into materials processes. In this exclusive design,<br />

the sample and reference pans are heated by two independent<br />

furnaces embedded in a temperature-controlled heat sink.<br />

This allows sophisticated analysis when performing the<br />

direct measurement of heat flow into or out of a sample.<br />

The Sapphire DSC<br />

The Sapphire DSC, the newest member of the PerkinElmer<br />

family of differential scanning calorimeters, is a heat flux<br />

DSC with broad temperature range and exceptional<br />

autosampler capabilities.<br />

The Sapphire DSC offers two inherent benefits because of<br />

its design: high sensitivity and excellent baseline stability.<br />

The unique heat flux oval sensor of the instrument<br />

provides extraordinary resolution and sensitivity and<br />

flat reproducible baselines.<br />

The power compensation DSC design leads to sharper<br />

peaks and high sensitivity. Additionally, benefits include<br />

true isothermal operation, modulated temperature DSC<br />

(StepScan) technique and HyperDSC for dramatic<br />

enhancements in sensitivity, as well as greater<br />

productivity. The Diamond DSC offers it all.<br />

The Diamond DSC features:<br />

■ Fastest heating and cooling rates<br />

■ Outstanding resolution<br />

■ Increased sensitivity<br />

■ True isothermal measurements<br />

■ High caloric accuracy<br />

Pyris 6 DSC<br />

The PYRIS TM 6 DSC is an ideal instrument for quality<br />

assurance/quality control and university laboratories.<br />

It performs routine experiments to characterize materials,<br />

predict product performance, optimize processing<br />

conditions, and improve quality.<br />

The PYRIS 6 DSC features:<br />

■ Exceptional value and performance<br />

■ Exceptional robustness and reliability<br />

■ Simple, inexpensive operation<br />

■ Space-saving footprint<br />

■ Easy-to-use Windows ® -based software<br />

Only PerkinElmer offers you a choice between two DSC<br />

models: a heat flux DSC and the power compensation DSC.<br />

No matter what your industry or application needs,<br />

PerkinElmer’s 40 years in the industry can offer the<br />

best solution for your analyses, based on your lab’s<br />

needs and budget.<br />

The Sapphire DSC features:<br />

■ Oval sensor for high resolution and sensitivity<br />

■ Highly reliable 50-position autosampler<br />

■ Multiple cooling options and pan types for broad operation range<br />

HyperDSC<br />

HyperDSC is the only true fastscan DSC technique,<br />

with scanning rates of up to 500 °C/min. The technique<br />

allows you to obtain additional, often crucial information,<br />

in seconds rather than minutes and is only available on<br />

the Diamond DSC from PerkinElmer.<br />

Many of the world’s leading pharmaceutical and polymer<br />

R&D laboratories have adopted the technique because of<br />

it’s ability to provide information that previously may<br />

have gone undetected. The HyperDSC technique makes<br />

it easier to study polymorphism in pharmaceuticals and<br />

realistically simulate polymer processing conditions. In<br />

addition, scientists are also exploring the use of<br />

HyperDSC in protein analyses.<br />

www.perkinelmer.com/<strong>supplies</strong> 335


DSC Sample Pans and Crimpers<br />

DSC Sample Pan Quick Reference<br />

Thermal Analysis DSC Sample Pans and Crimpers<br />

For use with Diamond DSC, Pyris 1 DSC, DSC 7, DSC 6, Pyris 6 DSC, and Jade DSC<br />

Aluminum<br />

Operating Maximum Crimper<br />

Sample Pan Range Vol. (μL) Pressure Quantity (Sealer) Part No. Page #<br />

Open/Crimped Pans<br />

Standard Aluminum Pans and Covers -170˚ to 600 ˚C 40 Ambient 400 02190048 or 02190041 342<br />

B0139005 with<br />

B0508921<br />

Aluminum Pans for Photocalorimetric Analysis -170˚ to 600 ˚C 12.5 Ambient 100 Not Required B0196858 341<br />

Aluminum Sample Pans -170˚ to 600 ˚C 28 Ambient 200 N5356027 N5356010 342<br />

N5356028<br />

Aluminum Sample Pans -170˚ to 600 ˚C 45 Ambient 400 N5356027 N5356012 342<br />

N5356028<br />

Aluminum Sample Pans, High Volume -170˚ to 600 ˚C 90 Ambient 200 N5356027 N5356034 342<br />

N5356028<br />

Aluminum Sample Pans for Photo DSC -170˚ to 600 ˚C 50 Ambient 400 Not Required N5356025 341<br />

Aluminum Sample Pans for HyperDSC -170˚ to 600 ˚C 50 Ambient 100 Not Required N5203115<br />

Vented/Pierced Pans<br />

Aluminum Covers (Pierced) -170˚ to 600 ˚C 0.05 mm hole 400 B7001014 338<br />

Volatile Aluminum Pans and Covers (Pierced) -170˚ to 600 ˚C 20 0.05 mm hole 100 02190061 or N5190788 346<br />

B0139005 with<br />

B0144637<br />

Aluminum (Vented) -170˚ to 600 ˚C 30 Vented 400 B0139005 B0143018 338<br />

Aluminum (Vented) -170˚ to 600 ˚C 50 Vented 400 B0139005 B0143019 338<br />

Hermetically Sealed/Volatile Pans<br />

Aluminum Pans -170˚ to 600 ˚C 10 1 bar 400 B0139005 B0143015 338<br />

Aluminum Pans -170˚ to 600 ˚C 30 1 bar 400 B0139005 B0143016 338<br />

Aluminum Pans -170˚ to 600 ˚C 50 1 bar 400 B0139005 B0143017 338<br />

Aluminum Pans and Covers -170˚ to 600 ˚C 20 2 bar 400 02190061 or 02190062 339<br />

B0139005 with<br />

B0144637<br />

Aluminum Pans and Covers -170˚ to 600 ˚C 10 3 bar 400 B0139005 B0169319 338<br />

Aluminum Pans and Covers -170˚ to 600 ˚C 30 3 bar 400 B0139005 B0169320 338<br />

Aluminum Pans and Covers -170˚ to 600 ˚C 50 3 bar 400 B0139005 B0169321 338<br />

Non-Coated Aluminum Sample Pans and Covers -170˚ to 500 ˚C 7.5 3 bar 200 N5356027 N5356008 339<br />

N5356028<br />

Alodined Aluminum Sample Pans and Covers -170˚ to 300 ˚C 7.5 3 bar 200 N5356027 N5356009 339<br />

N5356028<br />

Aluminum Sample Pans and Covers, Small Volume -170˚ to 500 ˚C 15 30 bar 40 N5356027 N5356003 340<br />

N5356028<br />

Aluminum Sample Pans and Covers, High Volume -170˚ to 500 ˚C 70 30 bar 40 N5356027 or N5356002 340<br />

N5356028<br />

Sample Pan Kits<br />

Aluminum Pan and Cover Starter Kit 3 bar 200/200 B0139005 B0510800<br />

Ceramic<br />

For use with Sapphire DSC<br />

Open/Crimped Pans<br />

Alumina Pans and Covers -170˚ to 730 ˚C 40 Ambient 6 Not Required N5190180 343<br />

Ceramic Sample Pans RT to 1500 ˚C 25 Ambient 5 Not Required N5356019 343<br />

Ceramic Sample Pans RT to 1500 ˚C 55 Ambient 2 Not Required N5356020 343<br />

336


DSC Sample Pans and Crimpers<br />

DSC Sample Pan Quick Reference<br />

For use with Diamond DSC, Pyris 1 DSC, DSC 7, DSC 6, Pyris 6 DSC, and Jade DSC<br />

Copper<br />

Operating Maximum Crimper<br />

Sample Pan Range Vol. (μL) Pressure Quantity (Sealer) Part No. Page #<br />

Open/Crimped Pans<br />

Standard Copper Pans and Covers -170˚ to 730 ˚C Ambient 200 02190048 03190026 342<br />

Copper Sample Pans -170˚ to 800 ˚C 45 Ambient 200 Not Required N5356021 342<br />

Gold<br />

Open/Crimped Pans<br />

Standard Gold Pans and Covers -170˚ to 730 ˚C 40 Ambient 10 02190048 02190042 342<br />

Hermetically Sealed/Volatile Pans<br />

Volatile Gold Pans and Covers -170˚ to 730 ˚C 20 2 bar 10 02190061 or 02190080 339<br />

B0139005 with<br />

B0144637<br />

High Pressure Gold-Plated Pans and Covers -170˚ to 400 ˚C 30 150 bar 5 B0182864 B0182902 340<br />

Graphite<br />

Open/Crimped Pans<br />

Graphite Pans and Covers -170˚ to 730 ˚C 40 Ambient 4 Not Required 03190025 343<br />

Platinum<br />

Open/Crimped Pans<br />

Platinum Pans and Covers -170˚ to 730 ˚C 40 Ambient 4 Not Required 03190024 343<br />

Platinum Sample Pans -170˚ to 1500 ˚C 45 Ambient 5 Not Required N5356016 343<br />

Platinum Sample Pans -170˚ to 1500 ˚C 95 Ambient 5 Not Required N5356017 343<br />

Silver<br />

Hermetically Sealed/Volatile Pans<br />

Silver Sample Pans and Covers (Small Volume) -170˚ to 600 ˚C 15 50 bar 20 N5356027 N5356005 340<br />

N5356028<br />

Silver Sample Pans and Covers (High Volume) -170˚ to 600 ˚C 70 50 bar 20 N5356027 N5356004 340<br />

N5356028<br />

Stainless Steel<br />

Hermetically Sealed/Volatile Pans<br />

Stainless Steel Pans, Covers, and O-Rings -40˚ to 300 ˚C 60 24 bar 20 09908467 or 03190218 340<br />

B0139005 with<br />

B0505340<br />

Stainless Steel Pans, Covers, and O-Rings -40˚ to 300 ˚C 60 24 bar 1000 09908467 or 03190029 340<br />

B0139005 with<br />

B0505341<br />

High Pressure Stainless Steel Pans and Covers -170˚ to 400 ˚C 30 150 bar 5 B0182864 B0182901 340<br />

Stainless Steel Sample Pans and Covers (Small Vol.) -170˚ to 800 ˚C 15 50 bar 20 N5356027 N5356007 340<br />

N5356028<br />

Stainless Steel Sample Pans and Covers (High Vol.) -170˚ to 800 ˚C 70 50 bar 20 N5356027 N5356006 340<br />

N5356028<br />

Titanium<br />

For use with Sapphire DSC<br />

Open/Crimped Pans<br />

High Pressure Titanium Pans and Covers -170˚ to 400 ˚C 30 150 bar 5 B0182864 B0182903 340<br />

DSC Sample Pans and Crimpers Thermal Analysis<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

337


DSC Sample Pans and Crimpers<br />

Autosampler Sample Pan and Covers<br />

Thermal Analysis DSC Sample Pans and Crimpers<br />

For use with Diamond DSC, Pyris 1 DSC, DSC 7, DSC 6, Pyris 6 DSC, and Jade DSC<br />

Autosampler Sample Pans and Covers<br />

The autosampler pans are available in sealed or vented versions. These pans may also be used for non-robotic systems.<br />

Operating Maximum Crimper<br />

Sample Pan Range Vol. (μL) Pressure Quantity (Sealer) Part No. Each (€)<br />

Aluminum (Vented) 1 -170˚ to 600 ˚C 30 Vented 400 B0139005 B0143018 289<br />

Aluminum (Vented) 1 -170˚ to 600 ˚C 50 Vented 400 B0139005 B0143019 237<br />

Aluminum Pans 1, 2 -170˚ to 600 ˚C 10 1 bar 400 B0139005 B0143015 237<br />

Aluminum Pans 1, 2 -170˚ to 600 ˚C 30 1 bar 400 B0139005 B0143016 289<br />

Aluminum Pans 1, 2 -170˚ to 600 ˚C 50 1 bar 400 B0139005 B0143017 237<br />

Aluminum Covers 3 -170˚ to 600 ˚C 400 B0143003 237<br />

Aluminum Pans and Covers 2 -170˚ to 600 ˚C 10 3 bar 400 B0139005 B0169319 970<br />

Aluminum Pans and Covers 2 -170˚ to 600 ˚C 30 3 bar 400 B0139005 B0169320 970<br />

Aluminum Pans and Covers 2 -170˚ to 600 ˚C 50 3 bar 400 B0139005 B0169321 970<br />

Aluminum Covers (Pierced) 4 -170˚ to 600 ˚C 0.05 mm hole 400 B7001014 422<br />

Aluminum Sample Pans 2, 5 -170˚ to 600 ˚C 28 Ambient 200 N5356027 N5356010 174<br />

N5356028<br />

Aluminum Sample Pans 6 -170˚ to 600 ˚C 45 Ambient 400 N5356027 N5356012 269<br />

N5356028<br />

1<br />

Require Covers (B0143003)<br />

2<br />

Can be used with all Autosamplers<br />

3<br />

For use with (B0143015, B0143016, B0143017, B0143018, and B0143019)<br />

4<br />

For use with (B0169319, B0169320, and B0169321)<br />

5<br />

Requires Autosampler Pan Die and Stage (N5356031)<br />

6<br />

Cover Plate style (N5356015)<br />

For use with Sapphire DSC<br />

338


DSC Sample Pans and Crimpers<br />

Hermetically Sealed Sample Pans (up to 3 bar)<br />

For use with Diamond DSC, Pyris 1 DSC, DSC 7, DSC 6, Pyris 6 DSC, and Jade DSC<br />

Hermetically Sealed Sample Pans (up to 3 bar)<br />

Hermetically sealed sample pans are used with volatile<br />

solid or liquid samples which exert significant vapor<br />

pressure at the temperature of interest. Available in both<br />

aluminum and gold pans.<br />

Pans can withstand an internal pressure up to 3 bar<br />

The heats of fusion of materials which sublime can be<br />

determined accurately<br />

The effect of an enclosed atmosphere on thermal behavior<br />

of a sample can be observed<br />

Capsules have an effective volume of up to 50 microliters<br />

Gold pans are available for samples requiring temperatures<br />

above 600 °C<br />

For use with Sapphire DSC<br />

Operating Maximum Crimper<br />

Sample Pan Range Vol. (μL) Pressure Quantity (Sealer) Part No. Each (€)<br />

Aluminum Pans 1, 2 -170˚ to 600 ˚C 10 1 bar 400 B0139005 B0143015 237<br />

Aluminum Pans 1, 2 -170˚ to 600 ˚C 30 1 bar 400 B0139005 B0143016 289<br />

Aluminum Pans 1, 2 -170˚ to 600 ˚C 50 1 bar 400 B0139005 B0143017 237<br />

Aluminum Covers 3 -170˚ to 600 ˚C 400 B0143003 237<br />

Aluminum Pans and Covers 2 -170˚ to 600 ˚C 10 3 bar 400 B0139005 B0169319 970<br />

Aluminum Pans and Covers 2 -170˚ to 600 ˚C 30 3 bar 400 B0139005 B0169320 970<br />

Aluminum Pans and Covers 2 -170˚ to 600 ˚C 50 3 bar 400 B0139005 B0169321 970<br />

Non-Coated Aluminum Sample Pans and Covers 5 -170˚ to 500 ˚C 7.5 3 bar 200 N5356027 N5356008 333<br />

N5356028<br />

Alodined Aluminum Sample Pans and Covers 5 -170˚ to 300 ˚C 7.5 3 bar 200 N5356027 N5356009 476<br />

N5356028<br />

Volatile Aluminum Pans and Covers 4 -170˚ to 600 ˚C 20 2 bar 400 02190061 or 02190062 443<br />

B0139005 with<br />

B0144637<br />

Volatile Gold Pans and Covers -170˚ to 730 ˚C 20 2 bar 10 02190060 or 02190080 1078<br />

B0139005 with<br />

B0144637<br />

1<br />

Require Covers (B0143003)<br />

2<br />

Can be used with all Autosamplers<br />

3<br />

For use with (B0143015, B0143016, and B0143017)<br />

4<br />

Can be used with all Mechanical Autosamplers<br />

5<br />

Requires Die (N5356036) and Stage (N5356035)<br />

Major Applications<br />

Purity analyses (i.e., pharmaceuticals, melting of lipids,<br />

or liquid crystals)<br />

Phase transitions, heat of vaporization, and boiling points<br />

DSC Sample Pans and Crimpers Thermal Analysis<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

339


DSC Sample Pans and Crimpers<br />

High Pressure Sample Pans (24 to 150 bar)<br />

Thermal Analysis DSC Sample Pans and Crimpers<br />

For use with Diamond DSC, Pyris 1 DSC, DSC 7, DSC 6, Pyris 6 DSC, and Jade DSC<br />

High Pressure Sample Pans (24 to 150 bar)<br />

Pans contain the sample in a sealed environment throughout<br />

an experiment. The sealing suppresses the vaporization of a<br />

solvent or contains a volatile reaction product, thereby<br />

eliminating the interfering effects of the heat of vaporization.<br />

Stainless Steel Pans with O-Ring:<br />

Sealed pans prevent any mass loss<br />

Pans can withstand an internal pressure of 24 bar<br />

High internal pressure capability allows water samples<br />

to be heated higher than 100 °C<br />

Large sample capacity yields higher sensitivity<br />

Operating range of -40° to 300 °C, unless otherwise<br />

limited by sample vapor pressure<br />

Under no circumstances should<br />

the pans be heated above 300 °C.<br />

Any application requiring<br />

the heating beyond 200 °C or<br />

where gaseous decomposition<br />

products may be generated<br />

should first be tested outside<br />

of the instrument.<br />

Major Applications<br />

For use with Sapphire DSC<br />

Operating Maximum Crimper<br />

Sample Pan Range Vol. (μL) Pressure Quantity (Sealer) Part No. Each (€)<br />

Aluminum Sample Pans and Covers, High Volume 3 -170˚ to 500 ˚C 70 30 bar 40 N5356027 N5356002 333<br />

N5356028<br />

Aluminum Sample Pans and Covers, Small Volume 3 -170˚ to 500 ˚C 15 30 bar 40 N5356027 N5356003 333<br />

N5356028<br />

Gold-Plated Pans, Covers, and Seals 1 -170˚ to 400 ˚C 30 150 bar 5 B0182864 B0182902 950<br />

Stainless Steel Pans, Covers, and Seals 1 -170˚ to 400 ˚C 30 150 bar 5 B0182864 B0182901 228<br />

Titanium Pans, Covers, and Seals 2 -170˚ to 400 ˚C 30 150 bar 5 B0182864 B0182903 1218<br />

Silver Sample Pans and Covers, High Volume 3 -170˚ to 600 ˚C 70 50 bar 20 N5356027 N5356004 445<br />

N5356028<br />

Silver Sample Pans and Covers, Small Volume 3 -170˚ to 600 ˚C 15 50 bar 20 N5356027 N5356005 412<br />

N5356028<br />

Stainless Steel Pans, Covers, and O-Rings -40˚ to 300 ˚C 60 24 bar 20 B0139005 with 03190218 176<br />

B0505340<br />

Stainless Steel Pans, Covers, and O-Rings -40˚ to 300 ˚C 60 24 bar 1000 B0139005 with 03190029 4363<br />

B0505340<br />

Stainless Steel Sample Pans and Covers (Small Vol.) -170˚ to 800 ˚C 15 50 bar 20 N5356027 N5356007 412<br />

N5356028<br />

Stainless Steel Sample Pans and Covers (High Vol.) -170˚ to 800 ˚C 70 50 bar 20 N5356027 N5356006 412<br />

N5356028<br />

1<br />

Reusable, includes 5 Pans and 20 Gold-Plated Seals, uses Replacement Seals (B0182905)<br />

2<br />

Reusable, includes 5 Pans and 20 Titanium Seals, uses Replacement Seals (B0185054)<br />

3<br />

Electric Sealer (N5356028) requires Hermetic Die (N5356032) and Stage (N5356035), included with Manual Sealer<br />

The study of aqueous biological solutions (such as protein<br />

in water) where the dilution requires large sample sizes<br />

and water vaporization must be suppressed<br />

Epoxy phenolic curing and vulcanization of rubber where the<br />

loss of volatiles can otherwise make interpretation difficult<br />

Reusable 150 Bar High Pressure Pans<br />

These reusable capsules can contain up to 150 bar. Their<br />

unique design includes a bursting disk on the cover of the<br />

capsule which allows the sample to safely vent if the pressure<br />

should exceed 150 atmospheres.<br />

The use of high pressure capsules in DSC permits<br />

suppressing the endothermic signal resulting from the<br />

volatilization of sample material or from the volatilization<br />

or decomposition of reaction by-products<br />

High pressure capsules permit the study of explosive materials<br />

and can be used in any situation where the advantage of a<br />

self-generating atmosphere is to be employed<br />

Capsules available in steel, gold-plated steel, and titanium<br />

Can withstand a maximum internal pressure up to 150 bar<br />

Capsules are reusable after sealing<br />

Used in hazard testing, curing reactions<br />

340


DSC Sample Pans and Crimpers<br />

Large Volume Pans (55 to 90 μL) and Photo DSC Sample Pans<br />

For use with Diamond DSC, Pyris 1 DSC, DSC 7, DSC 6, Pyris 6 DSC, and Jade DSC<br />

Large Volume Sample Pans (55 to 90 μL)<br />

Operating Maximum Crimper<br />

Sample Pan Range Vol. (μL) Pressure Quantity (Sealer) Part No. Each (€)<br />

Aluminum Sample Pans 1 -170˚ to 600 ˚C 90 open 200 N5356027 N5356034 286<br />

N5356028<br />

Aluminum Sample Pans and Covers 1 -170˚ to 500 ˚C 70 30 bar 40 N5356027 N5356002 333<br />

N5356028<br />

Ceramic Sample Pans RT to 1500 ˚C 55 open 2 Not Required N5356020 333<br />

Stainless Steel Pans, Covers, and O-Rings -40˚ to 300 ˚C 60 24 bar 20 B0139005 with 03190218 176<br />

B0505340<br />

Stainless Steel Pans, Covers, and O-Rings -40˚ to 300 ˚C 60 24 bar 1000 B0139005 with 03190029 4363<br />

B0505340<br />

1<br />

Electric Sealer (N5356028) requires Hermetic Die (N5356032) and Stage (N5356035)<br />

Large Volume Stainless<br />

Steel Capsule Kit<br />

Part No.<br />

Each (€)<br />

03190021 1875<br />

Kit Includes: Part No. Each (€)<br />

Quick Press 09908467 1301<br />

Quick Press Spacer Die 03191047 140<br />

Guard Ring Inserts, 1 pair 03190236 134<br />

20 Pans, Covers, and O-Rings 03190218 176<br />

Photo DSC Pans<br />

For use with Sapphire DSC<br />

Large Volume and Volatile Sample Pans<br />

Large Volume Stainless Steel Pans are designed for high pressure, large capacity analysis. Capsules contain the sample in a<br />

sealed environment throughout an experiment. The Viton TM O-Ring allows formation of a seal which suppresses the vaporization<br />

of a solvent or contains a volatile reaction product, thereby eliminating the interfering effects of the heat of vaporization.<br />

The photocalorimetric accessory extends the use of the Diamond DSC and permits to quantitatively measure the enthalpy<br />

changes (heat flow) in a material during and after exposure to UV light.<br />

Operating Maximum Crimper<br />

Sample Pan Range Vol. (μL) Pressure Quantity (Sealer) Part No. Each (€)<br />

Aluminum Pans for Photocalorimetric Analysis -170˚ to 600 ˚C 12.5 Ambient 100 Not Required B0196858 550<br />

Pans and Quartz Covers -170˚ to 600 ˚C 12.5 Ambient 100 Not Required B0198030 1469<br />

Quartz Covers 10 B0181091 93<br />

Aluminum Sample Pans for Photo DSC 1 -170˚ to 600 ˚C 50 Ambient 400 Not Required N5356025 238<br />

Aluminum Covers for Photo DSC 2 -170˚ to 600 ˚C 400 N5356026 238<br />

1<br />

For thin samples with Photo DSC (PDC121)<br />

2<br />

For thin Sample Pan (N5356025) with Photo DSC (PDC121)<br />

DSC Sample Pans and Crimpers Thermal Analysis<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

341


DSC Sample Pans and Crimpers<br />

Open Sample Pans<br />

Thermal Analysis DSC Sample Pans and Crimpers<br />

For use with Diamond DSC, Pyris 1 DSC, DSC 7, DSC 6, Pyris 6 DSC, and Jade DSC<br />

Open Sample Pans<br />

PerkinElmer offers sample pans to satisfy the needs of<br />

most thermal analysts. Ambient sample pans are available<br />

in aluminum, copper, or gold with the option for crimping.<br />

For special applications you can chose from alumina/<br />

ceramic, platinum, or graphite pans.<br />

In the crimped standard sample pan, the sample is completely<br />

enclosed in a highly conductive capsule and distributed in a<br />

thin layer such that the internal resistance in the sample<br />

itself is very small<br />

Due to the high thermal conductivities of aluminum, copper,<br />

and gold, heat transfer is maximized. This means that sample<br />

size can be minimized<br />

Because of their high-temperature capabilities, platinum and<br />

gold can be used to 730 °C<br />

Aluminum Copper Gold<br />

1<br />

Not for use with Diamond DSC, PYRIS 1 DSC, or DSC 7 Autosampler<br />

2<br />

Cover (N5356011)<br />

3<br />

Can be used with Autosampler, requires Autosampler Pan Die and Stage (N5356031)<br />

4<br />

Cover Crimp style (N5356014). Not for DSC Autosampler, requires Crimping Die and Stage (N5366030)<br />

5<br />

Cover Plate style (N5356015)<br />

6<br />

Copper Mesh Cover (N5356022)<br />

7<br />

Stainless Steel Mesh Cover (N5356023)<br />

8<br />

Recommended for O.I.T. tests<br />

For use with Sapphire DSC<br />

Aluminum Sample Pans and Covers<br />

Used with nonvolatile solid samples, such as polymers<br />

and pharmaceuticals. Routinely used for applications<br />

such as polymer melting, crystallization, glass transitions<br />

of polymers, thermoplastics, and thermosets. Pans are<br />

crimped but not hermetically sealed.<br />

Copper Sample Pans and Covers<br />

Can be used for samples that have transitions that occur<br />

above the temperature range of the aluminum pans.<br />

Typical applications include antioxidant testing (O.I.T.),<br />

thermoset and thermoplastic glass transition, and melting<br />

point determinations.<br />

Gold Sample Pans and Covers<br />

Used for any non-metal, i.e., ceramics, coal, soils, or<br />

minerals. Can also be used for any material that reacts<br />

with aluminum or which must be heated over 600 °C.<br />

Operating Maximum Crimper<br />

Sample Pan Range Vol. (μL) Pressure Quantity (Sealer) Part No. Each (€)<br />

Standard Aluminum Pans and Covers 1 -170˚ to 600 ˚C 40 Ambient 400 02190048 or 02190041 434<br />

B0139005 with<br />

B0508921<br />

Standard Copper Pans and Covers 1 -170˚ to 730 ˚C 40 Ambient 200 02190048 03190026 297<br />

Standard Gold Pans and Covers 1 -170˚ to 730 ˚C 40 Ambient 10 02190048 02190042 2035<br />

Aluminum Sample Pans 2, 3 -170˚ to 600 ˚C 28 Ambient 200 N5356027 N5356010 174<br />

N5356028<br />

Aluminum Sample Pans 4, 5 -170˚ to 600 ˚C 45 Ambient 400 N5356027 N5356012 269<br />

N5356028<br />

Aluminum Sample Pans, High Volume 4, 5 -170˚ to 600 ˚C 90 Ambient 200 N5356027 N5356034 286<br />

N5356028<br />

Copper Sample Pans 6, 7, 8 -170˚ to 800 ˚C 45 Ambient 200 Not Required N5356021 255<br />

342


DSC Sample Pans and Crimpers<br />

Open Sample Pans<br />

For use with Diamond DSC, Pyris 1 DSC, DSC 7, DSC 6, Pyris 6 DSC, and Jade DSC<br />

Alumina/Ceramic Sample Pans and Covers<br />

Used for oxidation studies of metals, minerals, ceramics,<br />

clays, and soils. They can also be used for melting and<br />

eutectic diagrams in the metals industry. The covers are<br />

pierced. A crimper is not required.<br />

Graphite Sample Pans and Covers<br />

Use in an inert atmosphere. They are primarily used with<br />

metals, but not for oxidation studies. They have extremely<br />

good heat transfer properties which yield sharp transition<br />

curves. A crimper is not required.<br />

Platinum Sample Pans and Covers<br />

Use these pans and covers when gold and graphite pans and<br />

covers are not suitable. Used to analyze mineral, soil, and<br />

ceramic samples. They are also used to allow a chemical<br />

reaction where platinum acts as a catalyst. They are easy to<br />

clean and reusable. A crimper is not required.<br />

For use with Sapphire DSC<br />

Operating Maximum Crimper<br />

Sample Pan Range Vol. (μL) Pressure Quantity (Sealer) Part No. Each (€)<br />

Alumina Pans and Covers -170˚ to 730 ˚C 40 Ambient 6 Not Required N5190180 395<br />

Ceramic Sample Pans 1 RT to 1500 ˚C 25 Ambient 5 Not Required N5356019 174<br />

Ceramic Sample Pans 1 RT to 1500 ˚C 55 Ambient 2 Not Required N5356020 333<br />

Graphite Pans and Covers -170˚ to 730 ˚C 40 Ambient 4 Not Required 03190025 297<br />

Platinum Pans and Covers* -170˚ to 730 ˚C 40 Ambient 4 Not Required 03190024 950<br />

Platinum Sample Pans 2 -170˚ to 1500 ˚C 45 Ambient 5 Not Required N5356016 507<br />

Platinum Sample Pans, High Volume 2 -170˚ to 1500 ˚C 95 Ambient 5 Not Required N5356017 507<br />

1<br />

No Covers<br />

2<br />

Plate Covers (N5356018)<br />

* While Supplies Last<br />

Alumina/Ceramic<br />

Graphite<br />

Platinum<br />

DSC Sample Pans and Crimpers Thermal Analysis<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

343


DSC Sample Pans and Crimpers<br />

Universal Crimpers<br />

Thermal Analysis DSC Sample Pans and Crimpers<br />

For use with Diamond DSC, Pyris 1 DSC, DSC 7, DSC 6, Pyris 6 DSC, and Jade DSC<br />

Crimpers and Sealers<br />

High-Pressure Capsule Sealing Tool<br />

Quick Press<br />

For use with: Seal Pans (03190218<br />

and 03190029) and requires<br />

Spacer Die (03191047).<br />

This reliable sealing tool is fast<br />

and precise. It employs a built-in<br />

torque clutch which guarantees<br />

that all capsules are closed with<br />

the same torque.<br />

For use with: Seal Pans (B0182901,<br />

B0182902, and B0182903).<br />

Standard Sample Pan Crimper Press<br />

Used to crimp covers on standard DSC pans of<br />

aluminum, gold, and copper. Design incorporates a<br />

replaceable crimper head.<br />

For use with: Crimp Pans (02190041 and 03190026)<br />

and Replacement Crimper Head (02191171).<br />

Crimpers for Sapphire DSC Pans<br />

Universal Crimper Press<br />

For use with Sapphire DSC<br />

The Universal Crimper Press provides high quality pan<br />

sealing for the autosampler sample pans/Hermetically<br />

sealed pans and can also crimp standard aluminum pans,<br />

large volume stainless steel (24 bar), and volatile pans.<br />

This is achieved simply by using the appropriate sealing<br />

insert. Includes sample pan suction tool and inserts to<br />

seal 10, 30, and 50 μL sample pans.<br />

Requires:<br />

Insert (B0144637) for Volatile Sample Pans (02190062,<br />

02190080, and N5190788), Insert (B0505340) for Stainless<br />

Steel Pans (03190218 and 03190029), Insert (B0508921) for<br />

Standard Aluminum Pans (02190041),<br />

and Insert (B0139033) for Hermetically Part No. Each (€)<br />

10, 30, and 50 μL Pans included.<br />

B0139005 2328<br />

Description Crimper (Sealer) Part No. Each (€)<br />

Manual Sample Pan Crimper (Sealer) with Die and Stage, Includes Hermetic Die (N5356032), N5356027 2381<br />

Stage (N5356035), and Extruding Rod (N5356033)<br />

Part No.<br />

Each (€)<br />

B0182864 1951<br />

Part No.<br />

Each (€)<br />

09908467 1301<br />

Part No.<br />

Each (€)<br />

02190048 1742<br />

Electric Driven Sample Pan Crimper (Sealer) without Die and Stage, Requires Die and Stage N5356028 6000<br />

Die and Stage for Crimpable Sample Pan, Seal Pans (N5356012 and N5356034) N5356027 or N5356030 1403<br />

N5356028<br />

Die and Stage for Autosampler Sample Pan, Seal Pans (N5356010) N5356027 or N5356031 225<br />

N5356028<br />

Die for Hermetic Sample Pan, Seal all Pans 30 and 50 bar, included in manual Standard Pan Crimper N5356028 N5356032 311<br />

Stage for Hermetic Sample Pan, Required for Hermetic Die (N5356032) or Die for Simple N5356028 N5356035 429<br />

Seal (N5356036), included with Manual Sample Pan Crimper<br />

Die for Simple Seal, Seals Pans (N5356008 and N5356009), requires Stage for Hermetic Seal (N5356035) N5356027 or N5356036 251<br />

N5356028<br />

Extruding Rod for Hermetic Sample Pan Sealer, For Hermetic Sample Pan Sealer N5356027 or N5356033 530<br />

N5356028<br />

344


DSC Supplies and Accessories<br />

Autosampler Supplies and Accessories<br />

PerkinElmer Diamond DSC Autosampler provides the<br />

automation, convenience, and flexibility you need!<br />

Allows automated DSC testing of up to 48 samples<br />

for the PYRIS 1 DSC and 44 samples for the Diamond DSC<br />

without operator attention<br />

Handles 10, 30, and 50 μL sealed pans and vented (open)<br />

pans as well as high pressure capsules<br />

Complete software control from a computer keyboard<br />

simplifies operation<br />

Diamond DSC, PYRIS 1 DSC<br />

Autosampler, and DSC 7 Robotic<br />

System Supplies and Accessories<br />

Magazine Kit B0142511 695<br />

Set of 12 magazines.<br />

Platinum Cover for Sample and B0139122 186<br />

Reference Cells, two required.<br />

1 Slide Key B0139120 166<br />

One end is magnetized for easy removal of magazines from the<br />

sample carousel. Other end (not magnetic) is used to insert<br />

magazines in sample carousel.<br />

Used to insert and remove the sample magazine through the<br />

access port in the cover<br />

Inserting magazines with the slide key prevents humidity and<br />

dust from entering the working space when changing samples<br />

2 Special Sample Pan Manipulator B0142512 300<br />

Specially designed to simplify the pickup and positioning of<br />

your sample pans and covers<br />

Stainless steel handle incorporates suction device<br />

5 Standard Sample Pan Manipulator B0143263 74<br />

Prevents contamination of your sample<br />

Simplifies the handling of your sample pans and covers<br />

Replacement Rubber Tip<br />

Used on the Sample Pan Manipulators, the Autosampler<br />

Sample Arm, and the Robotic system. Replace the rubber<br />

tip regularly for reliable operation.<br />

Part No. Each (€)<br />

Large Platinum Furnace Cover<br />

Used when running sample specimens<br />

in large volume stainless steel pans<br />

with the Autosampler. Two required.<br />

N5376097 29<br />

Part No.<br />

Each (€)<br />

B0182981 668<br />

Diamond DSC Autosampler<br />

Sample Preparation Recommendations<br />

2<br />

Never touch your sample, sample pan,<br />

sample cover, or platinum cover with your bare<br />

fingers. Body oils and greases may cause<br />

contamination and erroneous results.<br />

1<br />

DSC Supplies and Accessories Thermal Analysis<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

345


DSC Supplies and Accessories<br />

DSC High Pressure Cells and Accessories<br />

Thermal Analysis DSC Supplies and Accessories<br />

DSC High Pressure Cell Part No. N5200001<br />

Accessories<br />

Replacement Sample Holder<br />

for DSC High Pressure Cell<br />

Replacement sample holder for use with the DSC High<br />

Pressure Cell tested to meet all<br />

temperature and pressure specifications. Part No. Each (€)<br />

O-Ring for DSC High Pressure<br />

Cell Enclosure Cover<br />

Aluminum Sample Holder Cover<br />

for DSC High Pressure Cell<br />

Glass Wool Pads<br />

for DSC High Pressure Cell<br />

Sample Handling Tray<br />

for DSC High Pressure Cell<br />

Vapor Pressure Pan Kit<br />

N0200015 1073<br />

Part No.<br />

Each (€)<br />

B0199379 1<br />

Part No.<br />

Each (€)<br />

B0500724 140<br />

Part No.<br />

Each (€)<br />

B0500722 98<br />

Part No.<br />

Each (€)<br />

N5201016 148<br />

This kit includes 100 volatile aluminum pans and 100 pierced<br />

covers. A 50-micron diameter hole is centered in the cover.<br />

Use this kit for more reproducible measurements of boiling<br />

points, heats of vaporization, and sublimation temperatures.<br />

Vapor pressure studies can be conducted when using these<br />

pans and covers with the High Pressure DSC or the TGA.<br />

Maximum temperature is 600 °C. Use Sealer (02190061) or<br />

Universal Press (B0139005) with<br />

Sealing Insert (B0144637). 100 of each. Part No. Each (€)<br />

N5190788 300<br />

DSC High Pressure Cells<br />

The DSC High Pressure Cell is an accessory for performing<br />

DSC experiments at elevated pressure. The accessory<br />

operates with the Differential Scanning Calorimeters that<br />

use the unique PerkinElmer power compensated principle.<br />

Pressure range is 42 bar (600 psi) maximum; temperature<br />

range is 40° to 600 °C.<br />

Typical applications include:<br />

Oxidation testing of oils, fats, foods, and plastics<br />

Curing and crosslinking reactions<br />

Suppression of evaporation of volatiles<br />

Analysis of pressure-dependent chemical reactions<br />

There are built-in connections for a liquid cooling system<br />

(tap water or circulating system). PerkinElmer Service<br />

installation is recommended.<br />

Diamond DSC High Pressure Cell Kit<br />

Includes: DSC High Pressure Cell<br />

(N5200001) and Diamond DSC High<br />

Pressure Connection Kit (N5360321).<br />

Diamond DSC Connection Kit<br />

Upgrade kit for existing DSC 7<br />

customers who need to use DSC 7<br />

High Pressure Cell on Diamond DSC.<br />

DSC 7, DSC-4, and DSC-2<br />

High Pressure Cell<br />

Pyris 1 DSC High Pressure Cell Kit<br />

Includes: DSC High Pressure Cell<br />

(N5200001) and PYRIS 1 DSC High<br />

Pressure Connection Kit (N5370298).<br />

Part No.<br />

PYRIS 1 DSC High Pressure Connection Kit<br />

Each (€)<br />

N5360188 15700<br />

Part No.<br />

Each (€)<br />

N5360321 708<br />

Part No.<br />

Each (€)<br />

N5200001 14200<br />

Part No.<br />

Each (€)<br />

N5370299 15700<br />

Upgrade for existing DSC 7 or DSC 4 customers who need<br />

to use the High Pressure Cell<br />

(N5200001) on the PYRIS 1 DSC. Part No. Each (€)<br />

N5370298 708<br />

346


DSC Supplies and Accessories<br />

Intracoolers and Subambient Accessories<br />

Intracoolers<br />

Intracoolers from PerkinElmer are subambient devices<br />

that automatically control the flow of coolant through a<br />

circulating chamber attached to the Diamond DSC, PYRIS 1<br />

DSC, PYRIS 6 DSC, Sapphire DSC, DSC 7, TMA 7, or DMA 7<br />

analyzers. They are either single or dual-stage mechanical<br />

compression refrigeration units with a cylindrical expansion<br />

chamber and special bolts and insulation for mounting<br />

directly on the sample holder block of the Diamond DSC,<br />

PYRIS 1 DSC, PYRIS 6 DSC, and DSC 7, or the furnace<br />

assembly of the DMA 7 or TMA 7.<br />

Diamond DSC/PYRIS 1 DSC Intracooler 1P<br />

Allows for subambient operation to -30 °C.<br />

Voltage Part No. Each (€)<br />

115 V, 50/60 Hz N5370205<br />

230 V, 50/60 Hz N5370206 3290<br />

Diamond DSC/PYRIS 1 DSC Intracooler 2P<br />

Allows for subambient operation to -65 °C.<br />

Voltage Part No. Each (€)<br />

115 V, 50/60 Hz N5370207 6700<br />

230 V, 50/60 Hz N5370208 6700<br />

DSC 7 Intracooler 1<br />

Allows for subambient operation to -30 °C.<br />

Voltage Part No. Each (€)<br />

115 V, 50/60 Hz 03190205 3456<br />

230 V, 50/60 Hz 03190206 3456<br />

DSC 7 Intracooler 2<br />

Allows for subambient operation to -65 °C.<br />

Voltage Part No. Each (€)<br />

115 V, 50/60 Hz 03190207 6611<br />

230 V, 50/60 Hz 03190208 6700<br />

Intracooler SP Kit for Sapphire DSC<br />

Allows for subambient operation to -70 °C.<br />

Voltage Part No. Each (€)<br />

115 V N5350130 6700<br />

220 V N5350131 6700<br />

PYRIS 6 DSC Intracooler<br />

Allows for subambient operation to -80 °C.<br />

Voltage Part No. Each (€)<br />

115 V, 50/60 Hz N5374098 6700<br />

230 V, 50/60 Hz N5374099 6700<br />

PYRIS 6 DSC with Intracooler Hose Part No. N5374098<br />

Intracooler Spares<br />

Intracooler Bolt Kit for the Diamond<br />

DSC/PYRIS 1 DSC and DSC 7<br />

Includes: Part No. Each (€)<br />

Intracooler Bolt Insulating Disk 03191720 37<br />

Split Bushing 03191719 22<br />

Bolt 03191527 111<br />

Subambient Accessories for<br />

Diamond DSC/PYRIS 1 DSC<br />

Diamond DSC/PYRIS 1 DSC<br />

Part No.<br />

Each (€)<br />

03190247 255<br />

Description Part No. Each (€)<br />

CryoFill System N5370540 13400<br />

Includes LN 2 Control Box and CryoFill Dewar Tank<br />

CryoFill Dewar Tank, 50 L N5373009 3290<br />

Long LN 2 Transfer Line, 2 m N5372187 988<br />

Short LN 2 Transfer Line, 1 m N5372060 529<br />

LN 2 Septum Assembly (LN 2 Receptacle) N5370147 28<br />

LN 2 Cold Finger Threaded Solid Aluminum Cylinder 04191577 312<br />

For use with ice water bath or LN 2 .<br />

DSC Supplies and Accessories Thermal Analysis<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

347


DSC Supplies and Accessories<br />

Intracoolers and Subambient Accessories<br />

Thermal Analysis DSC Supplies and Accessories<br />

Subambient Accessories for DSC 7<br />

Dry Box Assembly<br />

Includes all mounting hardware.<br />

Description Part No. Each (€)<br />

With Irises N5190226 1518<br />

With Gloves N5190738 1887<br />

Cold Water Turbulent Chamber Kit<br />

This kit can be used with a cold water faucet or water circulator<br />

if ice is not available for the reservoir. (Included with the<br />

Ambient DSC 7).<br />

Description Part No. Each (€)<br />

Diamond DSC N5370142 401<br />

DSC 7 04190367 740<br />

Dry Box Glove Kit<br />

Allows existing dry box to be<br />

converted from Irises to gloves.<br />

Service installation recommended.<br />

Dry Box Sample Entry Port<br />

For DSC 7 Dry Box Assembly w/gloves.<br />

Dry Box Hold Down Screw<br />

Replacement Iris<br />

Eight required.<br />

Replacement Gloves with Arms<br />

Size 9.<br />

LN 2 Cold Finger Threaded Solid Aluminum Cylinder<br />

For use with ice water bath or LN 2 .<br />

DSC 7 Gasket<br />

Red rubber gasket between<br />

sample holder and deck lid.<br />

Part No.<br />

Each (€)<br />

N5190504 759<br />

Part No.<br />

Each (€)<br />

N5190784 456<br />

Part No.<br />

Each (€)<br />

09907504 8<br />

Part No.<br />

Each (€)<br />

N5191009 8<br />

Part No.<br />

Each (€)<br />

03191024 236<br />

Part No.<br />

Each (€)<br />

04191577 312<br />

Part No.<br />

Each (€)<br />

N5191845 77<br />

Subambient Accessories for<br />

PYRIS 6 DSC/DSC 6<br />

PRYIS 6 DSC/DSC 6 Subambient Kit<br />

Description Part No. Each (€)<br />

With Dewar N5200032 7100<br />

Without Dewar N5200033 1441<br />

Subambient Accessories for Sapphire DSC<br />

Air Cooling Accessory and Gas Switching<br />

Accessory for Sapphire DSC<br />

3 Channels: one to cool down furnace and the other two<br />

for gas switch. Requires, but does not<br />

include, Cooling Jacket (N5351002). Part No. Each (€)<br />

Cooling Jacket Sapphire DSC<br />

Required for LN 2 Automatic Gas<br />

Cooling Accessory (N5350110) and<br />

Air Cooling Accessory (N5350302).<br />

LN 2 Auto Cooling Accessory<br />

Allows operation of the Sapphire DSC from -150° to 725 °C.<br />

Requires, but does not include,<br />

Cooling Jacket (N5351002). Service<br />

installation recommended.<br />

Part No.<br />

N5350110<br />

Each (€)<br />

10600<br />

Cooling Can Accessory, Sapphire DSC<br />

N5350302 2743<br />

Part No.<br />

Each (€)<br />

N5351002 3809<br />

Manual LN 2 cooling device. Sits on top of the instrument.<br />

Enables ability to speed up cooling<br />

time between measurements and<br />

to start at subambient temperatures.<br />

Part No.<br />

N5351009<br />

Each (€)<br />

854<br />

348


DSC Supplies and Accessories<br />

Photocalorimeter Accessories and Supplies<br />

The Photocalorimeter Accessory extends the use of the<br />

Diamond DSC and permits the quantitative measurement of the<br />

enthalpy changes (heat flow) in a material during and after<br />

exposure to UV light. This configuration provides the most<br />

advanced system for the study of photo initiated reactions.<br />

Typical applications include:<br />

Monitoring the curing process for light-activated<br />

curing of printing inks and coatings<br />

Determining the effects of UV light on polymers<br />

in accelerated testing<br />

For information about the PerkinElmer Photocalorimeter Accessory, please<br />

contact your local PerkinElmer Sales Representative.<br />

Aluminum Capsules<br />

Aluminum Sample Pans and Covers<br />

for UV Curing Studies<br />

In response to requests from our customers, PerkinElmer<br />

developed these pans to allow reproducible isolation of small<br />

quantities of liquid samples (such as uncured resins) so that<br />

UV curing reactions may be more accurately monitored by<br />

DSC. Pans are available alone or with quartz covers. We<br />

recommend you use quartz covers when analyzing samples<br />

which will evaporate at the temperature of interest.<br />

Product Quantity Part No. Each (€)<br />

Aluminum Sample Pans* pkg. 100 B0196858 379<br />

Aluminum Sample Pans* 100 of Each B0198030 1469<br />

and Quartz Covers<br />

* Volume of 12.5 microliters<br />

Photocalorimeter Accessory<br />

Kit for Diamond DSC<br />

Photocalorimeter Accessory Kit<br />

The photocalorimeter accessory extends the use of the<br />

Diamond DSC and permits to quantitatively measure the<br />

enthalpy changes (heat flow) in a material during and after<br />

exposure to UV light. This configuration provides the most<br />

advanced system for the study of photo initiated reactions.<br />

Requires Service Engineer installation.<br />

Features:<br />

Short calorimetric response time of the DSC permits the<br />

analysis of even the most rapid curing reactions<br />

Precise isothermal temperature control of the power<br />

compensation Diamond DSC, even during the most rapid<br />

reaction, guarantees the accuracy of measurements<br />

Photofeedback system maintains constant lamp intensity,<br />

thus assuring accurate and consistent sample exposure<br />

Exposure intensity directly measured in the DSC analyzer<br />

Part No.<br />

Each (€)<br />

N5360016 23300<br />

Photocalorimeter Accessory<br />

Replacement Parts<br />

Quartz Window for Sample<br />

Cup Holder for Diamond DSC<br />

Graphite Disc<br />

Set of 2.<br />

Replacement Quartz Windows<br />

for DSC 7 Sample Holder Cover<br />

Two windows are required<br />

for each sample holder.<br />

Sample Holder Cover Without<br />

Quartz Window for DSC 7<br />

Part No. Each (€)<br />

N5365044 34<br />

Part No. Each (€)<br />

B0186924 31<br />

Part No. Each (€)<br />

B0066549 21<br />

Part No. Each (€)<br />

B0181576 718<br />

DSC Supplies and Accessories Thermal Analysis<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

349


DSC Supplies and Accessories<br />

Sample Holder Supplies and Calibration Reference Materials<br />

Thermal Analysis DSC Supplies and Accessories<br />

PYRIS 1 DSC Flow-Through Cover Kit Part No. N5370153<br />

DSC 7 Flow-Through Cover Kit Part No. 03190062<br />

O-Ring for Chimney Part No. 09902102<br />

DSC Calibration Reference Materials<br />

PerkinElmer reference materials are 99.999% pure. DSC<br />

requires elements of this purity so that the instrument can<br />

be accurately calibrated. Depend on PerkinElmer for quality<br />

calibration reference materials.<br />

Reference<br />

Transition<br />

Material Point Part No. Each (€)<br />

Indium 156.60 °C 03190033 29<br />

Tin 231.88 °C 03190034 75<br />

Lead 327.47 °C 03190035 43<br />

Zinc 419.47 °C 03190036 38<br />

Encapsulated Kit 02190045* 305<br />

for DSC 7, PYRIS 1 DSC, and Diamond DSC<br />

N5190762** 79<br />

* Includes a large and small indium, tin, and lead<br />

** Includes indium and zinc<br />

Specific Heat Kit<br />

Includes four sapphire disks manufactured to two separate<br />

diameters and thicknesses. Also includes a calibration chart<br />

giving the specific heat of aluminum<br />

oxide in the form of synthetic sapphire. Part No. Each (€)<br />

DSC Flow-Through Cover Kits<br />

DSC Flow-Through Cover Kits<br />

02190136 494<br />

The flow-through cover provides a short path for volatiles or<br />

decomposition products to exit from the DSC sample holder.<br />

When the flow-through cover is installed, the sliding sample<br />

holder enclosure cover is displaced by the accessory. The<br />

flow-through cover should be used with samples that undergo<br />

decomposition, dehydration, or oxidation, especially if<br />

the thermal conductivity of the products of the reaction<br />

is different from that of the purge gas.<br />

Description Part No. Each (€)<br />

Diamond DSC N5360142 1714<br />

PYRIS 1 DSC N5370153 1581<br />

DSC 7, DSC 4 03190062 1734<br />

O-Ring for Chimney<br />

Small, two required.<br />

O-Ring for DSC 7 Flow-Through Cover<br />

Large, two required.<br />

Part No.<br />

Each (€)<br />

09902102 1<br />

Part No.<br />

Each (€)<br />

09902205 4<br />

350


DSC Supplies and Accessories<br />

Sample Holder Supplies and Calibration Reference Materials<br />

Sample Holder Supplies<br />

Sample Holder Cover Reforming Tool<br />

DSC performance is enhanced with sample holder covers<br />

that are formed properly and not degraded by extended<br />

usage. This tool allows the analyst<br />

to reform the platinum covers to<br />

their original dimensions.<br />

Part No.<br />

03190030<br />

Each (€)<br />

837<br />

Vented Platinum Sample Holder Covers<br />

Each cover has two vent holes and is used for the Diamond<br />

DSC, PYRIS 1 DSC, and DSC 7 sample holders.<br />

Description Part No. Each (€)<br />

Kit of 2 04190299 214<br />

Kit of 6 03190031 563<br />

Forceps<br />

Sample Holder<br />

Cover Reforming Tool<br />

Part No. 03190030<br />

Hook Forceps<br />

Part No. 09908138<br />

Vented Platinum<br />

Sample Holder Cover<br />

Part No. 04190299<br />

Description Part No. Each (€)<br />

Flat Round Tips 09908400 60<br />

Flat Pointed Tips N5361078 183<br />

Hook 09908138 66<br />

Guard Ring Inserts<br />

A pair of removable, shaped aluminum inserts fitting in DSC<br />

sample holder cavities, preventing inadvertent dropping of<br />

pans, covers, etc., into the cavity. Also recommended for<br />

applications generating condensable gaseous products as<br />

the inserts are readily removed for cleaning.<br />

Description Part No. Each (€)<br />

DSC 7, DSC 4 (pair) 03190236 134<br />

PYRIS 1 DSC (pair) N5370236 408<br />

Diamond DSC (pair) N5360236 105<br />

DSC 7 Guard Ring Plastic Collar<br />

O-Ring for Swing-Away Cover<br />

For standard swing-away cover on<br />

DSC 7 and DSC 4.<br />

Diamond DSC Loading Tool<br />

Gasket for DSC 7 Draft Shield<br />

DSC 7 Gasket<br />

Guard Ring Inserts (pair)<br />

for PYRIS 1 DSC<br />

Part No. N5373126<br />

Red rubber gasket between<br />

sample holder and deck lid.<br />

Guard Ring Inserts (pair)<br />

for DSC 7, DSC 4<br />

Part No. 03190236<br />

Part No.<br />

Allows an easy insertion and<br />

removal of sample or reference<br />

pans or platinum covers.<br />

Part No.<br />

Each (€)<br />

N5361180 39<br />

Part No.<br />

Each (€)<br />

N5191085 42<br />

Part No.<br />

Each (€)<br />

N5191333 110<br />

Part No.<br />

Each (€)<br />

09902206 22<br />

Each (€)<br />

N5191845 77<br />

DSC Supplies and Accessories Thermal Analysis<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

351


DSC Supplies and Accessories<br />

Structure of Common Polymer Poster<br />

Thermal Analysis DSC Supplies and Accessories<br />

Melting Point (MP) and Glass Transition Temperature (Tg) are the most important thermodynamic<br />

parameters for the common polymers. These properties can be easily and quickly determined by DSC.<br />

Melting point temperature range (°C)<br />

Glass transition temperature range (°C)<br />

352


DTA Supplies and Accessories<br />

DTA Calibration Reference Materials and Supplies<br />

DTA 7 and DTA 1700 Supplies<br />

and Accessories<br />

Components Part No. Each (€)<br />

1 DTA Alumina Purge Gas Tube 04190119 204<br />

Located between the sample and<br />

reference cups; permits purging<br />

of the sample area (pkg. 2)<br />

2 Sample and Reference Cup Holders 04190163 1257<br />

95% platinum/5% rhodium cups<br />

0.47 cm diameter (pkg. 4)<br />

Aluminum Oxide Powder* 04190197 49<br />

Vial of 28 g<br />

4 Thermocouple Retaining Clips 04190117 56<br />

(pkg. 6)<br />

5 Thermocouple Support Post 04191228 408<br />

* Operating Tip: Place some aluminum oxide powder between<br />

the sample and the cup to prevent the sample from adhering<br />

to the cup.<br />

7 Sample and Reference Cups<br />

Alumina, platinum, and magnesia cups are available.<br />

Use alumina cups if the sample is to be brought to<br />

temperatures higher than 1500 °C and when metal<br />

samples are being run. Use magnesia cups for super<br />

conductor investigations. Use the platinum cups when<br />

alumina and magnesia cups are not suitable.<br />

Cup Material Size Quantity Part No. Each (€)<br />

Alumina 60 mm 3 1 04191290 34<br />

60 mm 3 6 04190166 192<br />

60 mm 3 25 04190387 883<br />

100 mm 3 1 04191291 111<br />

100 mm 3 6 04190217 643<br />

100 mm 3 25 04190388 1043<br />

Alumina Sample Pair N5380063 90<br />

Cup Lids<br />

Platinum 100 mm 3 10 04190165 1144<br />

Magnesia 60 mm 3 1 04191838 55<br />

100 mm 3 1 04191839 62<br />

Operating Tip: Since some samples will adhere to the cups,<br />

we recommend that you keep spare cups on hand.<br />

Components Part No. Each (€)<br />

9 Non-magnetic Straight Forceps 09908400 60<br />

DTA 7 Only Supplies and Accessories<br />

Components Part No. Each (€)<br />

3 Matched Sample and Reference N5380052 580<br />

Thermocouples*, matched pair, S-type<br />

O-Rings 09921019 2<br />

Furnace tube<br />

Base 09921018 3<br />

Purge tube 09902245 2<br />

Components Part No. Each (€)<br />

8 Alumina Furnace Tube N5380037 644<br />

Cylindrical with closed end. Placed<br />

over the cups to ensure even heating<br />

of both the sample and reference<br />

materials and to provide a controlled<br />

gas environment<br />

Oven Thermocouple Assembly, S-type N5380051 434<br />

Sapphire Cup for Oven Thermocouple N5191875 579<br />

Replacement Furnace Heater Assembly N5380053 7100<br />

DTA 7 Spares Kit N5380015 2765<br />

Hex Wrench 09907236 1<br />

Open Alumina Furnace Tube Kit N5380062 4285<br />

For collecting evolved gases<br />

generated during a DTA experiment<br />

Balance Cup Stand N5381081 29<br />

Use this stand to support the sample<br />

cup vertically while weighing your sample<br />

* Operating Tip: When replacing the thermocouple, replace<br />

both thermocouples because they are a matched pair.<br />

DTA Calibration Reference Materials<br />

Reference Material Transition Point Part No. Each (€)<br />

Aluminum 660.10 °C N5380057 18<br />

Gold 1063.00 °C N5380058 90<br />

Palladium 1551.85 °C N5380071 29<br />

7<br />

2<br />

9<br />

1<br />

4<br />

DTA 7<br />

5<br />

8<br />

7<br />

3<br />

6<br />

DTA Supplies and Accessories Thermal Analysis<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

353


Thermal Analysis Laboratory Products and Accessories<br />

Laboratory Products and Accessories<br />

Purge Gas Accessories<br />

Fittings<br />

(Included<br />

with Filter<br />

Dryer Kit)<br />

1 Filter Dryer Kit<br />

2<br />

Filters and Traps<br />

Filter Dryer<br />

Replacement<br />

Cartridge<br />

Filters<br />

1<br />

2<br />

3<br />

Filter Traps<br />

Copper Tubing<br />

Teflon<br />

Tubing<br />

NPT Connector (male)<br />

NPT Reducing<br />

Bushing (female)<br />

Filter Dryer Kit Part No. N5370103<br />

Components Part No. Each (€)<br />

Filter Dryer Kit N5370103 319<br />

Removes moisture and particulates<br />

from your purge gas<br />

Includes all the necessary fittings needed<br />

to make pneumatic connections easy<br />

Tape and tubing are not included,<br />

Filter Dryer Replacement Cartridge 09923454 46<br />

with a visual indicator for Hammond Dryer<br />

Type “H” Purge Gas Restrictor 01541498 93<br />

Provides a flow of about 1 cc/min. purge per pound of<br />

pressure for nitrogen, air, or oxygen. (For helium, the<br />

flow rate is substantially faster)<br />

Thread Sealant Tape 09908134 19<br />

Roll of Teflon tape, 1/4 in. x 260 in.<br />

The In-line Filter Trap removes moisture, oil, and dust from<br />

the gases before they flow into your instrument. It consists<br />

of a transparent acrylic tube containing a molecular sieve<br />

and a desiccant, Drierite. An indicator changes color to let<br />

you know when the packing must be changed, while the<br />

cartridge design makes replacement of the filter material<br />

easy. A refill kit is also available.<br />

In-line Filter Trap Part No. N9301178<br />

Description Part No. Each (€)<br />

Copper Gas Line Kit N2410170 217<br />

In-Line Filter Trap N9301178 200<br />

Refill Kit for the In-Line Filter Trap N9301176 29<br />

Flow Meters<br />

Allows you to accurately control and conserve purge gas<br />

Measures nitrogen flow from 0 to 100 cc/min.<br />

Includes 1/8 NPT female connections<br />

Diamond DMA Flow Meters<br />

Description Part No. Each (€)<br />

Flow Meter 20-140 mL/min. N5356000 1051<br />

Flow Meter 50-500 mL/min. N5356001 1051<br />

Float Displacement<br />

Flow Meter<br />

Gas Cylinder<br />

Installation Accessories<br />

Adjustable Wrench for Cylinder Pressure Regulators<br />

Adjustable 30 cm steel wrench<br />

opens out to 4.5 cm; fits all the<br />

regulators listed on this page.<br />

Gas Cylinder Safety Holders<br />

Keep your lab safe from toppled gas cylinders! Safety<br />

holders are designed for either wall mount or bench<br />

mount. Body of cast aluminum. Adjustable nylon web<br />

strap holds cylinders.<br />

Product Part No. Each (€)<br />

Wall Mount N9301298 101<br />

Bench Mount N9301299 101<br />

Gas Split Kit<br />

Allows for simple expansion of a limited supply of gas<br />

sources. A single resource can be split into individual<br />

regulated <strong>supplies</strong>. Maximum inlet<br />

pressure of 300 psi. Maximum outlet<br />

pressure or 150 psi.<br />

Part No.<br />

N5190462<br />

Each (€)<br />

166<br />

Gas Regulators and Accessories<br />

Oxygen Pressure Regulator<br />

Part No.<br />

Each (€)<br />

02901624 300<br />

Float Displacement Flow Meter<br />

Part No. 02901624<br />

Part No.<br />

Each (€)<br />

N9301324 55<br />

Guarantees constant delivery pressure even when cylinder<br />

pressure varies. Two-stage regulator with brass body and<br />

stainless steel diaphragm. Maximum inlet pressure of<br />

20,700 KPa. Supplied with CGA-540 adapter. Includes a<br />

Swagelok 1/4 in. NPT to 1/8 in. fitting, which is used to<br />

attach the regulator to the purge gas<br />

tubing. Approximate weight: 1.3 Kg. Part No. Each (€)<br />

02400084 606<br />

354


Helium/Nitrogen Pressure Regulator<br />

Two-stage regulator for precise outlet pressure control.<br />

Brass body and stainless steel diaphragm for long life<br />

and minimum maintenance. Maximum inlet pressure of<br />

20,700 KPa. Supplied with CGA-580<br />

adapter. Approximate weight: 1.3 Kg. Part No. Each<br />

Gas Pressure Regulator Features:<br />

Barstock Body Construction<br />

Barstock bodies have a lower internal volume than forged<br />

bodies, allowing for more complete purging of atmospheric<br />

contaminant's.<br />

Stainless Steel Diaphragms<br />

Unlike elastomeric diaphragms, stainless steel diaphragms<br />

don’t absorb atmospheric contaminant's or allow them to<br />

diffuse into the gas stream.<br />

Metal-to-Metal Seals<br />

Metal-to-metal seals provide reliable protection from<br />

inboard leakage of atmospheric contaminant's.<br />

Swagelok Reducing Fittings<br />

Size Part No. Each (€)<br />

1/4-1/8 in. 09903471 12<br />

1/4-1/4 in. 09903196 10<br />

Copper Line Assembly, 6 foot<br />

Includes 1/8 in. Swagelok<br />

fitting at each end.<br />

Gas Line Assembly, Plastic<br />

Type “H” Purge Gas Restrictor<br />

Provides a flow of about 1 cc/min.<br />

purge per pound of pressure for<br />

nitrogen, air, or oxygen. (For helium,<br />

the flow rate is substantially faster).<br />

Thread Sealant Tape<br />

Roll of Teflon tape, 1/4 x 260 in.<br />

Gas Selector Accessory<br />

The GSA 7 Gas Selector Accessory enables reproducible<br />

rapid sample atmosphere switching. With this gas selector,<br />

thermal experiments are totally automated, requiring no<br />

operator intervention during even the most complex<br />

analyses. Can be used with Diamond DSC, PYRIS 1 DSC,<br />

DSC 7, PYRIS 1 TGA, and TGA 7.<br />

Product Voltage Part No. Each (€)<br />

GSA 7 Gas Selector Accessory 100 V N5190269 2771<br />

115 V N5190270 2771<br />

230 V N5190271 2771<br />

3<br />

Laboratory Products and Accessories<br />

02400085 606<br />

Part No.<br />

Each (€)<br />

02400011 85<br />

Part No.<br />

Each (€)<br />

N2410147 79<br />

Type “H”<br />

Restrictor<br />

Part No.<br />

Each (€)<br />

01541498 93<br />

Part No.<br />

(€)<br />

Each (€)<br />

09908134 19<br />

Purge Gas Accessories<br />

Diamond Air Cooling and Gas Switching Accessory<br />

For Diamond TG/DTA, Diamond TMA,<br />

and Diamond DMA. 3 channels: One<br />

for cooling down the furnace and<br />

2 for purge gas switching.<br />

Gas Station for Thermal Analysis<br />

Use the Thermal Analysis Gas<br />

Station (TAGS), a gas selector<br />

accessory with all thermal<br />

analyzers. The TAGS is a very<br />

flexible accessory featuring full<br />

control of all gases used in<br />

thermal analysis. In addition<br />

to performing gas switching,<br />

the TAGS also fully controls<br />

the gas flow rate, independent<br />

of the type of gas, and detects<br />

rapid changes in pressure and<br />

empty cylinders.<br />

Part No.<br />

Each (€)<br />

N5350202 2532<br />

TAGS Uses Calibrated Massflow Controls<br />

Massflow controllers provide more accurate control of flow<br />

rates than pressure controls, consequently reproducibility<br />

of results (when studying effect of flow rate on material<br />

properties) is improved. Massflow controls measure and<br />

controls the flow of gases independent of changes in<br />

pressure and temperature.<br />

TAGS is Simple to Program<br />

With the PYRIS Series software, TAGS is fully computercontrolled<br />

utilizing up to four different gases. Gas switching<br />

can be done on a time or temperature program.<br />

With the 7 Series/Unix software, TAGS can operate by<br />

monitoring the instrument furnace temperature and can<br />

switch between any of four gases at a programmed<br />

temperature or programmed time. Multiple gas switching<br />

methods can be developed and stored in TAGS memory.<br />

GSA 7 Gas Selector<br />

Part No. N5190270<br />

Thermal Analysis Gas Station (TAGS)<br />

Part No.<br />

Each (€)<br />

N5202019 5400<br />

Laboratory Products and Accessories Thermal Analysis<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

355


Mechanical Analysis (DMA)<br />

3-Point Bending Measuring Systems<br />

Thermal Analysis Mechanical Analysis (DMA)<br />

The bending measuring systems available from PerkinElmer<br />

are used to perform many of the classical mechanical testing<br />

applications. 3-Point bending is typically used with high<br />

modulus materials such as thermoplastics, resins, epoxy<br />

and graphite laminates, composites, and highly crystalline<br />

thermoplastics through Tg. Sample geometries include solid<br />

materials, such as bar stock, test plaques, test coupons,<br />

sheet stock, wire, rods, and tubes.<br />

Diamond DMA Bending<br />

Measuring System<br />

3-Point Bending<br />

3-Point Bending<br />

Measuring System*<br />

Part No.<br />

* More Bending Systems in Dual Cantilever Section<br />

DMA 7/DMA 7e 3-Point Bending<br />

System Replacement Parts<br />

Each (€)<br />

N5353035 2381<br />

Components Part No. Each (€)<br />

1 Universal DMA Sample Tube N5390107 714<br />

For use with stainless steel 3-Point Bending, Extension, and<br />

Parallel Plate measuring systems<br />

2 Universal DMA Probe Tip Holder N5390105 344<br />

For use with stainless steel 3-Point Bending, 2-Point, 3-Point/<br />

4-Point Bending, Single and Dual Cantilever, and Parallel Plate<br />

measuring systems. Includes Probe Tip Holder (N5390104),<br />

Collet (N5391004), and Lock Nut (N5391003)<br />

3 Knife Edge Bending Platform 5 mm N5390102 198<br />

10 mm N5390197 198<br />

4<br />

15 mm N5390101 198<br />

5<br />

20 mm N5390122 198<br />

6 Knife Edge Probe Tip 10 mm N5391016 91<br />

7<br />

5 mm N5391063 91<br />

8<br />

(sphere) 3 mm N5391017 40<br />

9 Hex Nut 09911186 1<br />

1<br />

6<br />

7 8<br />

2<br />

3 4 5<br />

9<br />

DMA 7/DMA 7e Large Adjustable<br />

3-Point/4-Point Bending Kit<br />

This kit provides for the analysis of extremely high modulus<br />

samples and larger samples. Standard test bars, i.e., dog<br />

bones, test plaque, and other samples up to 165 mm long<br />

can be tested with this kit. This kit<br />

complies with ASTM Standard D790.<br />

Kit includes:<br />

Part No.<br />

N5390478<br />

Each (€)<br />

4886<br />

Product Part No. Each (€)<br />

Large Platform N5390420 1862<br />

10 mm 4-Point Bending Probe Tip N5390453 459<br />

15 mm 4-Point Bending Probe Tip N5390452 459<br />

20 mm 4-Point Bending Probe Tip N5390451 459<br />

10 mm Knife 3-Point Bending Probe Tip N5391016 91<br />

3 mm Spherical Probe Tip N5391017 40<br />

Universal DMA Probe Tip Holder N5390105 344<br />

Split Ferrule N5191662 91<br />

Collar N5391054 91<br />

DMA 7/DMA 7e Measuring<br />

Parts for ASTM 5934-96<br />

Cylindrical Probe Tip<br />

Rounded 3-Point Bending Platforms<br />

Part No.<br />

Each (€)<br />

N5390175 281<br />

These platforms are designed<br />

to address several ASTM test<br />

procedures which require rounded<br />

rather than knife-edge surfaces on<br />

bending platforms.<br />

Width Part No. Each (€)<br />

5 mm N5390428 198<br />

15 mm N5390427 198<br />

20 mm N5390426 198<br />

356


Mechanical Analysis (DMA)<br />

3-Point Bending Measuring Systems<br />

DMA 7/DMA 7e Quartz 3-Point<br />

Bending Measuring Systems<br />

and Replacement Parts<br />

DMA Quartz 3-Point Bending Systems<br />

Similar to the stainless steel 3-Point measuring system but<br />

of quartz construction. Measuring systems are shipped in an<br />

attractive wooden case and include 1 mm hemispherical tip<br />

probe, 3 mm knife probe, 5 mm knife probe, mounting<br />

hardware, spare shims, and instructions.<br />

Description Part No. Each (€)<br />

For use with the Standard Furnace N5390136 2627<br />

For use with the High-Temperature Furnace N5390137 2627<br />

DMA 7/DMA 7e 3-Point Bending<br />

Probe Alignment Tools<br />

For Knife-edge Spacing.<br />

Size Part No. Each (€)<br />

5 mm N5391095 48<br />

10 mm N5391183 255<br />

15 mm N5391094 119<br />

20 mm N5391093 60<br />

Quartz 3-Point Bending Sample Tubes<br />

Components Part No. Each (€)<br />

10 10 Used with Standard Furnace, N5191472 714<br />

11<br />

part of N5390136 kit<br />

Used with High-Temperature Furnace, N5191549 555<br />

part of N5390137 kit<br />

12 12 Bending Platform N5391181 644<br />

Quartz Probes<br />

Quartz 10 mm 3-Point bending platform is permanently<br />

fused to the base of the sample tube. Used with the<br />

High-Temperature Furnace (Not shown.)<br />

Part of Quartz 3-Point Bending Systems<br />

(N5390137 and N5390136).<br />

Components Part No. Each (€)<br />

13 13 1 mm Round Tip Probe N5190377 504<br />

(Hemispherical, 0.02 in.)<br />

14 14 3 mm Knife-Edge Probe N5190393 619<br />

15 15 7 mm Knife-Edge Probe N5190614 542<br />

High-Temperature Tape 02507907 56<br />

For securing thermocouple to the sample tube<br />

Quartz Measuring System<br />

for Standard Furnace<br />

Part No. N5390136<br />

11<br />

12<br />

Quartz 3-Point<br />

Bending Sample Tubes<br />

Stainless Steel<br />

Measuring System<br />

Part No. N5390137<br />

10<br />

13 14 15<br />

Quartz Probes<br />

Mechanical Analysis (DMA) Thermal Analysis<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

357


Mechanical Analysis (DMA)<br />

Bending/Dual Cantilever Measuring Systems<br />

Thermal Analysis Mechanical Analysis (DMA)<br />

4<br />

1<br />

Bending<br />

3<br />

2<br />

The Dual Cantilever measuring system is used to perform<br />

many of the classical mechanical testing applications.<br />

It is typically used with medium-modulus materials<br />

such as elastomers and materials above their glass<br />

transition temperature.<br />

Low-mass clamping system allows optimum temperature<br />

accuracy, faster scanning rates, faster temperature<br />

equilibrium, and cool-down<br />

Vertical mounting ensures that forces are collinear<br />

Since no static force is required, analysis can continue even<br />

as sample melts<br />

Measuring system can easily be modified to perform single<br />

cantilever analyses<br />

Diamond DMA Bending Measuring System/<br />

(Dual Cantilever)<br />

Description Part No. Each (€)<br />

8 mm N5353083 1428<br />

20 mm N5353081 2477<br />

32 mm N5353082 1714<br />

Chuck and Clamp 20 mm for Bending N5353084 1094<br />

Plate, Gap Setting in Bending N5353079 451<br />

Torque Wrench Set N5353087 620<br />

DMA 7/DMA 7e Dual Cantilever Measuring<br />

System and Replacement Parts<br />

Dual Cantilever Measuring System<br />

Used to analyze materials with mid-range modulus. Two<br />

different measuring systems are supplied: a high-modulus<br />

system which is recommended when the storage modulus<br />

is greater than 1 x 108, and a low-modulus system which<br />

is recommended when the storage modulus is less than<br />

1 x 108. Measuring system is shipped in an attractive<br />

wooden case and includes high-modulus and low-modulus<br />

sample tubes, a universal probe tip holder, a dual cantilever<br />

probe tip, a center clamp assembly,<br />

a hex ball driver, and instructions. Part No. Each (€)<br />

Components Part No. Each (€)<br />

1 Dual Cantilever Sample Tube N5390176 803<br />

Includes side clamp fixture assembly, high-modulus type<br />

2 Universal DMA 7/DMA 7e N5390105 344<br />

Probe Tip Holder<br />

For use with the stainless steel Single and Dual Cantilever,<br />

2-, 3-, and 4-Point Bending, and Parallel Plate measuring<br />

systems, includes Probe Tip Holder (N5390104), Collet<br />

(N5391004), and Lock Nut (N5391003)<br />

3 Center Clamp Assembly N5390175 281<br />

Used on low-modulus and high-modulus sample tube<br />

4 Dual Cantilever Sample Tube N5390174 1065<br />

Includes side clamp fixture assembly, low-modulus type<br />

High-Temperature Tape 02507907 56<br />

For securing thermocouple to the sample tube<br />

N5390131 3233<br />

358


Mechanical Analysis (DMA)<br />

Compression/Expansion Measuring Systems<br />

Diamond DMA Measuring<br />

System and Parts<br />

DMA 7/DMA 7e Parallel<br />

Plates with Tray Kits<br />

Compression Measuring System<br />

The compression head uses the<br />

components of the tension head.<br />

There is one size for the compression<br />

head containing one top plate and<br />

one bottom plate.<br />

Torque Wrench Set<br />

DMA 7/DMA 7e<br />

Cup and Plate Kits<br />

Compression<br />

Part No.<br />

Each (€)<br />

N5353032 291<br />

Part No.<br />

Each (€)<br />

N5353087 620<br />

These kits include 5, 10, 15, and 20 mm diameter plates<br />

and 8, 13, 18, and 21.5 mm cups. They can be used to study<br />

low-modulus materials that have honey-like consistencies,<br />

or to study thermoplastics and rubbers which are above<br />

their Tg’s, or study samples that cure or melt, to or from,<br />

the liquid state.<br />

Product Part No. Each (€)<br />

Cup and Plate Trial Kit N5390464 261<br />

Includes:<br />

8 mm Cup and 5 mm Plate; 13 mm Cup and 10 mm Plate;<br />

18 mm Cup and 15 mm Plate; 21.5 mm Cup and 20 mm Plate;<br />

Instruction Sheet<br />

5 mm Cup and Plate Kit (10 of each) N5390465 434<br />

Includes:<br />

8 mm Cup and 5 mm Plate<br />

10 mm Cup and Plate Kit (10 of each) N5390466 675<br />

Includes:<br />

13 mm Cup and 10 mm Plate<br />

15 mm Cup and Plate Kit (10 of each) N5390467 510<br />

Includes:<br />

18 mm Cup and 15 mm Plate<br />

20 mm Cup and Plate Kit (10 of each) N5390468 542<br />

Includes:<br />

21.5 mm Cup and 20 mm Plate<br />

These kits include plates with diameters of 5, 10, and 15 mm.<br />

They can be used with materials that become so fluid they<br />

flow out of the parallel plates. In this event, the bottom<br />

tray will act as a catch basin and prevent the liquid from<br />

flowing into the furnace. Use these kits for the study of<br />

thermoplastics and rubbers which are above their Tg’s.<br />

Product Part No. Each (€)<br />

Parallel Plates with Tray Trial Kit N5390469 300<br />

Includes (Bottom/Top):<br />

5 mm Parallel Plate with Tray/5 mm Plate<br />

10 mm Parallel Plate with Tray/10 mm Plate<br />

15 mm Parallel Plate with Tray/15 mm Plate<br />

Instruction Sheet<br />

5 mm Parallel Plate with Tray Kit N5390470 87<br />

Includes (Bottom/Top):<br />

5 mm Parallel Plate with Tray/5 mm Plate<br />

10 mm Parallel Plate with Tray Kit N5390471 94<br />

Includes (Bottom/Top):<br />

10 mm Parallel Plate with Tray/10 mm Plate<br />

15 mm Parallel Plate with Tray Kit N5390472 102<br />

Includes (Bottom/Top):<br />

15 mm Parallel Plate with Tray/15 mm Plate<br />

DMA 7/DMA 7e Cup and Plate Kits<br />

Part No. N5390466<br />

Sample<br />

Tray<br />

Top Plate<br />

DMA 7/DMA 7e Parallel Plates with Tray Kits<br />

Part No. N5390472<br />

Plate<br />

Cup<br />

Mechanical Analysis (DMA) Thermal Analysis<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

359


Mechanical Analysis (DMA)<br />

Compression/Expansion Measuring Systems<br />

Thermal Analysis Mechanical Analysis (DMA)<br />

2<br />

1<br />

5 6 7 8<br />

4 3<br />

9<br />

Stainless Steel Parallel Plate Measuring System Part No. N5390133<br />

DMA 7/DMA 7e Parallel<br />

Plate Measuring System<br />

and Replacement Parts<br />

Stainless Steel Parallel Plate Measuring System<br />

Measuring system is shipped in an attractive wooden case<br />

and includes 1, 3, 5, 10, and 20 mm parallel plates, mounting<br />

hardware, and instructions.<br />

Part No. Each (€)<br />

N5390133 2306<br />

Components Part No. Each (€)<br />

1 Universal DMA Sample Tube N5390107 714<br />

For use with Stainless Steel Parallel Plate, 3-Point Bending,<br />

and Extension measuring systems.<br />

2 Universal DMA Probe Tip Holder N5390105 344<br />

For use with Stainless Steel Parallel Plate, 2-, 3-, and 4-Point<br />

Bending. Single and Dual Cantilever measuring systems.<br />

Includes Probe Tip Holder (N5390104), Collet (N5391004),<br />

and Lock Nut (N5391005)<br />

Stainless Steel Parallel Plate Probe Tips<br />

3 Top only, 1 mm* N5391014 40<br />

4 Top only, 3 mm* N5391015 40<br />

5 Top and bottom, 5 mm* N5390143 126<br />

6 Top and bottom, 10 mm* N5390144 126<br />

7 Top and bottom, 15 mm* N5390145 126<br />

8 Top and bottom, 20 mm* N5390146 126<br />

9 Hex Nut 09911186 1<br />

High-Temperature Tape 02507907 56<br />

For securing thermocouple to the sample tube<br />

* Each stainless steel replacement parallel plate set includes<br />

the hex nut used to fasten the bottom plate to the probe<br />

tip holder.<br />

360


Mechanical Analysis (DMA)<br />

Compression/Expansion Measuring Systems<br />

DMA 7/DMA 7e Quartz Parallel<br />

Plate Measuring Systems<br />

and Replacement Parts<br />

Quartz Parallel Plate Systems<br />

Similar to the Stainless Steel Parallel Plate measuring system<br />

but of quartz construction. Measuring systems are shipped<br />

in an attractive wooden case and include 1, 3, and 6 mm<br />

parallel plate probes, mounting hardware, and instructions.<br />

Description Part No. Each (€)<br />

For use with the Standard Furnace N5390135 2627<br />

For use with the High-Temperature Furnace N5390138 2627<br />

Quartz Sample Tubes<br />

9<br />

10<br />

Description Part No. Each (€)<br />

Used with Standard Furnace, N5191837 676<br />

part of N5390135 kit<br />

Used with High-Temperature Furnace, N5191549 555<br />

part of N5390138 kit<br />

Quartz Parallel Plate Probes<br />

The following Quartz Probes are used on the Large<br />

and Small Quartz Parallel Plate measuring systems.<br />

11<br />

12<br />

13<br />

Description Part No. Each (€)<br />

1 mm N5190376 504<br />

3 mm N5190378 504<br />

6 mm N5190606 370<br />

DMA 7/DMA 7e Sintered<br />

Parallel Plate Kits<br />

These kits include 10, 15, and 20 mm diameter stainless<br />

steel plates. They can be used for materials with oil<br />

additives or solvents that otherwise slip between<br />

conventional parallel plates. Typical applications are<br />

rubbers, foods, lubricated polymers, and hydrogels.<br />

Product Part No. Each (€)<br />

Sintered Parallel Plates Trial Kit N5390460 363<br />

Includes (Bottom/Top):<br />

10 mm Sintered Parallel Plate/10 mm Sintered Parallel Plate<br />

15 mm Sintered Parallel Plate/15 mm Sintered Parallel Plate<br />

20 mm Sintered Parallel Plate/20 mm Sintered Parallel Plate<br />

Instruction Sheet<br />

10 mm Sintered Parallel Plates Kit (5 of each) N5390461 510<br />

Includes (Bottom/Top):<br />

10 mm Sintered Parallel Plate/10 mm Sintered Parallel Plate<br />

15 mm Sintered Parallel Plates Kit (5 of each) N5390462 510<br />

Includes (Bottom/Top):<br />

15 mm Sintered Parallel Plate/15 mm Sintered Parallel Plate<br />

20 mm Sintered Parallel Plates Kit (5 of each) N5390463 510<br />

Includes (Bottom/Top):<br />

20 mm Sintered Parallel Plate/20 mm Sintered Parallel Plate<br />

10<br />

Sample<br />

DMA 7/DMA 7e Sintered Parallel Plate Kits<br />

Part No. N5390460<br />

9<br />

Top Plate<br />

Bottom Plate<br />

Quartz Large and<br />

Small Parallel Plate<br />

Measuring Systems<br />

11 12 13<br />

Quartz Parallel Plate Measuring<br />

System for Standard Furnace<br />

Part No. N5390135<br />

Mechanical Analysis (DMA) Thermal Analysis<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

361


Mechanical Analysis (DMA)<br />

Extension and Shear Analysis Measuring Systems<br />

Thermal Analysis Mechanical Analysis (DMA)<br />

Diamond DMA Extension<br />

Measuring System and<br />

Replacement Parts<br />

The extension analysis measuring systems are used to<br />

measure materials such as thin films, textiles, and<br />

other fibers.<br />

Features:<br />

Fine resolution of force allows use of precise<br />

stresses and strains<br />

Wide bandwidth transducers and automatic sample<br />

corrections allow analysis of samples that experience<br />

massive expansion or shrinkage<br />

Blown Films:<br />

Determination of tensile properties<br />

Detection of orientation effects<br />

Detection of partial melting or recrystallization<br />

Analysis of heat-shrink materials<br />

Detection of oxidation, biodegradation, or aging<br />

Fibers, Yarns, and Monofilaments:<br />

Determination of tensile properties<br />

Analysis of single filaments, high- or low-denier fibers<br />

Determination of yarn heat-set points<br />

Extension Measuring System<br />

Part No. N5390132<br />

Tension<br />

Part No. N5353080<br />

Diamond DMA Extension Measuring System<br />

Part No.<br />

Each (€)<br />

N5353080 1808<br />

Description Part No. Each (€)<br />

Chuck Set-Probe Side for Tension N5353086 857<br />

Clamp Set-Base Side for Tension N5353085 906<br />

Plate, Gap Setting in Tension N5353078 309<br />

Torque Wrench Set N5353087 620<br />

DMA 7/DMA 7e Extension<br />

Measuring System and<br />

Replacement Parts<br />

DMA 7/DMA 7e Stainless Steel<br />

Extension Measuring System<br />

Used to study materials such as thin films and fibers.<br />

Includes a fixture which provides flat parallel clamping<br />

surfaces for analyzing materials such as films, and a fixture<br />

which provides tangential clamping surfaces for analyzing<br />

materials such as fibers or wire. Measuring system is shipped<br />

in an attractive wooden case and also includes an extension<br />

probe tip holder, mounting hardware,<br />

a hex ball driver, and instructions. Part No. Each (€)<br />

Used on standard furnace.<br />

N5390132 3287<br />

Components Part No. Each (€)<br />

1 2 Universal Sample Tube N5390107 714<br />

For use with the Stainless Steel Extension, 3-Point Bending,<br />

and Parallel Plate Measuring System<br />

2 2 Extension Probe Tip Holder N5390193 344<br />

Includes Probe Tip Holder Shaft (N5390112),<br />

Collet (N5391004), and Lock Nut (N5391003)<br />

Filter Clamp Assembly – Includes plate and screws<br />

3 3 Top N5390178 370<br />

4 4 Bottom N5390177 370<br />

Film Clamp Assembly<br />

5 5 Top N5390154 370<br />

6 6 Bottom N5390156 370<br />

7 7 Hex Nut 09911186 1<br />

Stainless Steel Extension<br />

Measuring System<br />

Part No. N5390132<br />

5<br />

6<br />

7<br />

2<br />

3<br />

4<br />

7<br />

1<br />

362


Mechanical Analysis (DMA)<br />

Extension and Shear Analysis Measuring Systems<br />

DMA 7/DMA 7e Quartz<br />

Extension Measuring System<br />

DMA 7/DMA 7e Quartz Extension Measuring System<br />

Used to study low-modulus materials such as thin films<br />

and fibers. Includes a fixture which provides flat parallel<br />

clamping surfaces, and a fixture which uses fiber pins and<br />

is especially suited for single filament samples. Measuring<br />

system is shipped in an attractive wooden case and also<br />

includes mounting hardware, 100<br />

fiber pins, and instructions. Used Part No. Each (€)<br />

on high-temperature furnace only.<br />

N5390134 3686<br />

DMA 7/DMA 7e Quartz<br />

Extension Measuring System<br />

and Replacement Parts<br />

Components Part No. Each (€)<br />

7 Quartz Sample Tube N5191700 523<br />

8 Quartz Probe N5190609 523<br />

9 Clamp Assembly N5190611 523<br />

Includes top and bottom clamps<br />

Sample Load Fixture N5190615 721<br />

Used to align and install sample<br />

into film sample clamps<br />

10 Fiber Pins (pkg. 100) N5390157 414<br />

10 High-Temperature Tape 02507907 56<br />

For securing thermocouple<br />

to the sample tube<br />

Shear Measuring System<br />

for Diamond DMA<br />

Diamond DMA Film Shear<br />

Measuring System<br />

Diamond DMA Shear Sandwich<br />

Measuring System<br />

Part No.<br />

Each (€)<br />

N5353031 2571<br />

Part No.<br />

Each (€)<br />

N5353030 3300<br />

7<br />

Quartz Extension Measuring System Part No. N5390134<br />

Film Shear<br />

Part No. N5353031<br />

9<br />

8<br />

Shear Sandwich<br />

Part No. N5353030<br />

10<br />

Mechanical Analysis (DMA) Thermal Analysis<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

363


Mechanical Analysis (TMA)<br />

TMA Measuring Systems<br />

Thermal Analysis Mechanical Analysis (TMA)<br />

Application Solutions<br />

with Multiple Probe Types<br />

Expansion: The expansion probe permits<br />

the direct determination of the coefficient<br />

of linear expansion, a characteristic and<br />

important property of any material.<br />

Penetration and Compression: Narrow<br />

tip compression probes are available<br />

for penetration measurements. A broad<br />

tip compression probe permits the<br />

determination of the compressive<br />

modulus and additional properties<br />

of soft rubber materials.<br />

Flexure: The deflection temperature of<br />

materials under load and other types of<br />

3-Point bending studies can be performed<br />

with the flexure analysis probe.<br />

Extension: Extension and contraction<br />

characteristics of fibers and films can<br />

be measured with this accessory.<br />

Dilatometer: Volumetric expansion<br />

and contraction can be measured with<br />

this accessory.<br />

Bending/Flexure<br />

Analysis Kits and Parts<br />

Permits deformation studies of films. Includes flexure<br />

analysis probe and platform.<br />

Product Part No. Each (€)<br />

Diamond TMA Quartz Bending Kit N5353023 3935<br />

Includes:<br />

Probe and 5 mm Platform,<br />

Diamond TMA Quartz Bending Probe N5353048 2528<br />

Diamond TMA Quartz,<br />

5 mm Bending Platform (Stage) N5353009 1688<br />

TMA 7 Flexure Analysis Kit N5190399 1135<br />

Includes:<br />

Probe and 5 mm Platform,<br />

TMA 7 Flexure Probe N5190393 619<br />

TMA 7 10 mm Flexure Analysis Sample Platform N5391181 644<br />

Dilatometer Kit<br />

Permits the determination of volumetric changes of materials<br />

as a function of temperature. The accessory is useful for<br />

materials whose linear coefficient of expansion cannot be<br />

easily determined by the expansion probe. The dilatometer is<br />

useful for determining the volume change of materials upon<br />

melting, or upon cooling from a melt. A typical application<br />

would be the determination of shrinkage from a mold.<br />

Diamond TMA<br />

Product Part No. Each (€)<br />

Includes: Sapphire Cup, Sapphire Plate, N5353095 531<br />

Probe, Alumina, and Spatula.<br />

TMA 7<br />

Product Part No. Each (€)<br />

Large Quartz Dilatometer Kit N5190763 1441<br />

1 mL capacity to be used with the large 28 mm diameter furnace<br />

Includes: Large Quartz Dilatometer Cell (barrel and plunger)<br />

Aluminum Oxide Powder 28 g<br />

Quartz Sample Tube<br />

Instruction Sheet<br />

Large Dilatometer Cell (Barrel and Plunger) N5192094 1288<br />

Small Quartz Dilatometer Kit 03190461 1467<br />

0.1 mL capacity to be used with the 15 mm diameter furnace<br />

Includes: Small Quartz Dilatometer Cell (barrel and plunger)<br />

Aluminum Oxide Powder 28 g<br />

Instruction Sheet<br />

Small Dilatometer Cell (Barrel and Plunger) 03191705 1377<br />

Aluminum Oxide Powder 04190197 49<br />

Vial of 28 g, filling medium<br />

364


Mechanical Analysis (TMA)<br />

TMA Measuring Systems<br />

Extension Analysis<br />

Kit and Parts<br />

Diamond TMA Quartz Tension Kit<br />

Allows distortion studies of drawn,<br />

spun, and cast fibers and films.<br />

Includes:<br />

Components Part No. Each (€)<br />

Diamond TMA Standard Furnace Quartz N5353041 2414<br />

Tension Probe<br />

Diamond TMA Standard Furnace Quartz N5353042 1000<br />

Tension Chuck<br />

Tool for Tension Sample Setup N5353045 620<br />

Diamond TMA Metal Tension<br />

Product Part No. Each (€)<br />

Diamond TMA Metal Tension Probe N5353043 597<br />

Diamond TMA Standard Furnace Metal Screw N5353046 165<br />

for Tension Chuck Probe (5 pcs.)<br />

Diamond TMA Standard Furnace Metal Screw N5353047 138<br />

for Tension Chuck Sample<br />

Diamond TMA Standard Furnace Tension Chuck (2) N5353044 914<br />

TMA 7 Extension Analysis Kit<br />

Comes with Sample Tube and Probe<br />

extension clamps, sample load<br />

fixture, and autozero standard.<br />

Also includes:<br />

Product Part No. Each (€)<br />

TMA 7 Extension Probe N5190609 523<br />

TMA 7 Extension Sample Tube N5191700 523<br />

TMA 7 Extension Sample Clamp N5190611 523<br />

TMA 7 Sample Load Fixture N5190615 721<br />

Used to align and install film<br />

sample into sample clamps<br />

Sample Tubes and Cylinders<br />

Diamond TMA<br />

Product Part No. Each (€)<br />

Standard Furnace Quartz Cylinder K-TC (Old-type) N5353013 1617<br />

Standard Furnace Quartz Cylinder with K-TC N5353050 1617<br />

Standard Furnace Quartz Cylinder without TC N5353054 1423<br />

Standard Furnace Metal Cylinder without TC N5353056 1051<br />

Standard Furnace Metal Cylinder with K-TC N5353052 1246<br />

High-Temperature Alumina Cylinder with N5353051 2697<br />

Platinum/Pt Rhodium Thermocouple<br />

K = Chromel/Alumel Thermocouple<br />

TMA 7<br />

Part No.<br />

Each (€)<br />

N5353021 3414<br />

Part No.<br />

Each (€)<br />

N5190619 3125<br />

Product Part No. Each (€)<br />

Quartz Sample Tube N5191549 555<br />

Required for the expansion, penetration,<br />

compression, and flexure modes of operation<br />

Quartz 3-Point Bending Sample Tube N5391181 644<br />

This tube differs from the standard sample<br />

tube in that the 10 mm bending platform is<br />

permanently fused to the base of the tube<br />

TMA 7 Expansion/Compression/<br />

Penetration Quartz Probes<br />

PerkinElmer’s quartz probes are manufactured to extremely<br />

high tolerances to ensure you obtain the most accurate data<br />

from your instrument.<br />

Product Part No. Each (€)<br />

1 Expansion Probe N5190378 504<br />

3.7 mm diameter flat tip<br />

2 Penetration Probe N5190376 504<br />

1 mm diameter flat tip<br />

3 Compression Probe<br />

0.5 mm radius spherical tip N5190377 504<br />

1.5 mm radius spherical tip N5190416 504<br />

1 2 3<br />

Diamond TMA Standard Furnace<br />

3<br />

2<br />

1<br />

Product Part No. Each (€)<br />

Aluminum Viscous Fluid Cup and N5356029 755<br />

Pin Set for Curing Studies<br />

Quartz Conical Penetration Probe N5353040 2526<br />

Quartz Penetration Probe (0.5 mm) N5353039 2571<br />

Quartz Penetration Probe (1.0 mm) N5353038 1571<br />

Quartz Sample Stage (5 pcs.) N5353057 263<br />

Quartz Expansion Probe N5353036 1197<br />

Diamond TMA High-Temperature Furnace<br />

Product Part No. Each (€)<br />

Alumina Expansion Probe N5353037 1106<br />

Alumina Sample Stage (5 pcs.) N5353059 763<br />

Mechanical Analysis (TMA) Thermal Analysis<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

365


Mechanical Analysis (TMA/DMA)<br />

Furnace Accessories, Reference Materials, and Supplies<br />

Thermal Analysis Mechanical Analysis (TMA/DMA)<br />

Diamond DMA/TMA Calibration<br />

Reference Materials and Tools<br />

Diamond DMA<br />

Product Part No. Each (€)<br />

Aluminum Plate N5353073 109<br />

PMMA, 0.2 x 8 x 40 mm N5353076 71<br />

PMMA, 1.5 x 10 x 50 mm N5353077 71<br />

Pure Iron Plate N5353074 263<br />

Stainless Steel Plate N5353075 237<br />

Diamond TMA<br />

Product Part No. Each (€)<br />

Aluminum Standard Cylinder for Standard Furnace N5353065 83<br />

Quartz Standard Cylinder for High-Temperature Furnace N5353140 203<br />

Diamond DMA/TMA Furnace<br />

Tubes, Thermocouples,<br />

and Accessories<br />

Diamond DMA<br />

Product Part No. Each (€)<br />

Immersion Liner N5353141 686<br />

Used to analyze samples in liquids. Temperature range:<br />

Rate to 80 °C (upper limit depends on liquid), Purge Gas:<br />

requires 1000 mL/min. or more dry air or nitrogen,<br />

Immersion liquid volume: maximum 15 mL.<br />

Diamond TMA<br />

Product Part No. Each (€)<br />

Front Plate for Vacuum Operation N5353116 1809<br />

Quartz Vacuum Accessory Kit N5353114 3619<br />

Standard Furnace<br />

Alumina Vacuum Accessory Kit N5353115 3333<br />

Immersion Studies Tube N5353144 7100<br />

Quartz Furnace Tube N5353062 1611<br />

Quartz Vacuum Furnace Tube N5353117 1809<br />

Thermocouple K-TC N5353060 194<br />

High-Temperature Furnace<br />

Alumina Furnace Tube N5353063 1351<br />

Alumina Vacuum Furnace Tube N5353118 1809<br />

Thermocouple R-TC N5353061 420<br />

5<br />

1<br />

2<br />

6 7<br />

8<br />

3<br />

4<br />

9<br />

DMA 7, DMA 7e, and TMA7<br />

Reference Materials<br />

10<br />

Components Part No. Each (€)<br />

1 Force Calibration Weight, 50 g 09908825 16<br />

2 Micrometer 09907281 332<br />

3 TMA 7 Extension Autozero Cylinder N5191792 46<br />

4 DMA Epoxy Reference Material (pkg.10) N5390128 191<br />

5 Zero Step Block for SS 3-Point Bending<br />

20 mm N5391090 91<br />

15 mm N5391104 148<br />

10 mm N5391184 191<br />

6 Eigendeformation Calibration Cylinder N5191469 9<br />

7 DMA 10 mm Height Calibration Cylinder N5391051 56<br />

8 Aluminum Cylinder 02191858 73<br />

for Expansion Measurement<br />

Indium Temperature 03190033 29<br />

Calibration Reference Material<br />

Zinc Temperature 03190036 38<br />

Calibration Reference Material<br />

Dual Cantilever Height Calibration Aid N5391085 90<br />

Sapphire Disk 02191269 125<br />

for TMA Ordinate Calibration<br />

DMA 7, DMA 7e, and TMA7<br />

Thermocouples, Furnaces,<br />

and Supplies<br />

Components Part No. Each (€)<br />

9 DMA/TMA 7 Sample Thermocouple N5190417 64<br />

10<br />

DMA Ceramic Thermocouple Insulator N5391048 23<br />

High-Temperature Tape 02507907 56<br />

for securing thermocouple<br />

to the sample tube<br />

Non-Magnetic Straight Tweezers 09908400 60<br />

Buoyancy Fluid 02190218 427<br />

DMA High-Temperature Furnace Install Kit N5390141 3482<br />

Designed to add High-Temperature<br />

capability to a DMA 7<br />

Includes heat sink, insulator, and<br />

High-Temperature furnace<br />

TMA 7 Large Furnace Install Kit N5190617 4349<br />

Designed to add large furnace<br />

capability to a TMA 7<br />

Includes heat sink, insulator, and<br />

large furnace<br />

Replacement DMA/TMA 7 Furnace<br />

Large, 28 mm i.d. (to 500 °C) N5190613 3482<br />

Small, High-Temperature 15 mm i.d. N5190370 2372<br />

(to 1000 °C)<br />

366


Calibration Reference Materials<br />

Description Transition Point Part No. Each (€)<br />

Aluminum 660.10 °C N5380057 18<br />

Gold 1063.00 °C N5380058 90<br />

Indium 156.60 °C 03190033 29<br />

Lead 327.47 °C 03190035 43<br />

Palladium 1551.85 °C N5380071 29<br />

Tin 231.88 °C 03190034 75<br />

Zinc 419.47 °C 03190036 38<br />

Furnace and Furnace Accessories<br />

Diamond Air Cooling and Gas Switching Accessory<br />

3 Channels: one to cool down furnace<br />

and the other two for gas switch.<br />

Balance Beam Socket Set for Diamond TG/DTA<br />

Plug-in type, Set of 2 alumina beams<br />

for sample and reference side,<br />

includes Thermocouple.<br />

Furnace Tube Standard<br />

Furnace Tube for Corrosive Gas<br />

Furnace Tube Vacuum<br />

Part No.<br />

TG/DTA Supplies and Accessories<br />

Each (€)<br />

N5350202 2532<br />

Part No.<br />

Each (€)<br />

N5352006 2381<br />

Part No.<br />

Each (€)<br />

N5352004 1825<br />

Part No.<br />

Each (€)<br />

N5352027 2644<br />

Part No.<br />

Each (€)<br />

N5352005 3174<br />

Diamond TG/DTA Supplies and Accessories<br />

Hyphenated Accessories<br />

Diamond TG/DTA Gas Transfer<br />

System Standard Unit<br />

Controller for heated transfer line.<br />

Gas Transfer Accessory for FTIR<br />

Heated transfer line – requires<br />

Gas Transfer System (N5350201)<br />

for temperature control.<br />

Gas Transfer Accessory for MS<br />

Heated transfer line – requires<br />

Gas Transfer System (N5350201)<br />

for temperature control.<br />

In-Line Filter Trap for<br />

Diamond TG/DTA<br />

Part No.<br />

Each (€)<br />

N5350201 6900<br />

Part No.<br />

Each (€)<br />

N5350203 714<br />

Part No.<br />

Each (€)<br />

N5350204 4285<br />

The In-line Filter Trap removes moisture, oil, and dust from<br />

the gases before they flow into your instrument. It consists<br />

of a transparent acrylic tube containing a molecular sieve<br />

and a desiccant, Drierite. An indicator changes color to let<br />

you know when the packing must be changed, while the<br />

cartridge design makes replacement of the filter material easy.<br />

Product Part No. Each (€)<br />

In-Line Filter Trap N9301178 200<br />

In-Line Filter Trap Refill Kit N9301176 29<br />

Sample Pans<br />

Description Qty. Part No. Each (€)<br />

Alumina Sample Pans, 25 uL Set of 5 N5356019 174<br />

Alumina Sample Pans, 55 uL Set of 2 N5356020 333<br />

Aluminum Cover for Autosampler Pans Set of 400 N5356026 238<br />

Aluminum Open Sample Pan Set of 400 N5356012 269<br />

Aluminum Open Sample Pan, 50 uL Set of 400 N5356025 238<br />

Aluminum Open Sample Pan, 90 uL Set of 200 N5356034 286<br />

Copper Mesh Cover Set of 200 N5356022 88<br />

Used with N5356021<br />

to fix sample position<br />

Copper, Open Sample Pan, 45 uL Set of 200 N5356021 255<br />

Platinum Cover for Open Pan Set of 5 N5356018 174<br />

Platinum, Open Sample Pan, 45 uL Set of 5 N5356016 507<br />

Platinum, Open Sample Pan, 90 uL Set of 5 N5356017 507<br />

Stainless Steel Mesh Cover Set of 200 N5356023 88<br />

TG/DTA Supplies and Accessories Thermal Analysis<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

367


TGA Supplies and Accessories<br />

Calibration Reference Materials<br />

Thermal Analysis TGA Supplies and Accessories<br />

Calibration Reference Materials for Temperature Calibration<br />

of PerkinElmer TGA Furnaces Pyris 1 TGA, TGA 6, and TGA 7<br />

Ensure accurate thermogravimetric measurements with<br />

PerkinElmer magnetic reference materials.<br />

Kit of Five Reference Materials<br />

Including Alumel, Nickel, Perkalloy,<br />

Iron, and Hisat-50 (one piece each).<br />

Alumel Reference Material<br />

Three 2 in. pieces of Alumel wire.<br />

Magnetic transition temperature<br />

of 154.2 °C.<br />

Nickel Reference Material<br />

Three 2 in. pieces of 99.99% Nickel<br />

wire. Magnetic transition temperature<br />

of 355.3 °C.<br />

Perkalloy Reference Material<br />

Three 2 in. pieces of Perkalloy wire.<br />

Magnetic transition temperature<br />

of 596 °C.<br />

Iron Reference Material<br />

Three 2 in. pieces of 99.99% Iron wire.<br />

Magnetic transition temperature<br />

of 780 °C.<br />

Part No.<br />

Each (€)<br />

02190071 102<br />

Part No.<br />

Each (€)<br />

09988015 66<br />

Part No.<br />

Each (€)<br />

N5190869 66<br />

Part No.<br />

Each (€)<br />

N5190616 66<br />

Part No.<br />

Each (€)<br />

09988017 66<br />

Magnetic Calibration Reference Materials are available in kit form and now are<br />

also available separately for your convenience. We recommend that you use<br />

fresh reference materials each time you calibrate your instrument. In this way<br />

you can avoid the effects of hysteresis and oxidation on the Curie point of the<br />

reference materials.<br />

368


TGA Supplies and Accessories<br />

Furnace and Furnace Accessories<br />

Conversion Kits*<br />

PYRIS 1 TGA Standard to<br />

High-Temperature Conversion Kit<br />

Designed to add high-temperature<br />

furnace capability to a PYRIS 1 TGA<br />

equipped with a standard furnace.<br />

PYRIS 1 TGA High-Temperature to<br />

Standard Conversion Kit<br />

Designed to add standard furnace<br />

capability to a TGA equipped with<br />

a high-temperature furnace.<br />

TGA 7 Standard Furnace Install Kit<br />

Designed to add standard furnace capability to a TGA 7<br />

Thermogravimetric Analyzer<br />

with high-temperature furnace.<br />

Part No. Each (€)<br />

TGA 7 High-Temperature Furnace Install Kit<br />

Designed to add high-temperature furnace capability to a<br />

TGA 7 Thermogravimetric Analyzer<br />

equipped with the standard furnace.<br />

Part No. Each (€)<br />

N5190510 12500<br />

* PerkinElmer Service installation required.<br />

Furnace Accessories and<br />

Glassware for TGA Standard<br />

and High-Temperature<br />

1<br />

2<br />

Standard TGA TGA High-Temperature<br />

Components Part No. Each (€) Part No. Each (€)<br />

Furnace N5190264 1862 N5190172 7900<br />

Furnace Thermocouple N5190196 459<br />

Cup for Furnace N5191875 579<br />

Thermocouple<br />

Sample Thermocouple 03190253 421 N5190197 644<br />

Sample Thermocouple N5190786 861<br />

Furnace Tube Quartz<br />

TGA 7 N5190203 344<br />

PYRIS 1 TGA N5370459 344 N5190202 548<br />

Platinum Furnace Shield 03191628 893<br />

PRYIS 6 TGA<br />

Part No.<br />

Each (€)<br />

N5370332 12100<br />

Part No.<br />

Each (€)<br />

N5370331 3813<br />

N5190511 6300<br />

Description Part No. Each (€)<br />

Ceramic Sample Cup Holder N5203020 332<br />

Replacement Furnace Thermocouple N5376817 279<br />

Replacement Sample Thermocouple N5376806 386<br />

Calibration Weight for PYRIS 6 TGA N5200042 47<br />

Components Part No. Each (€)<br />

1 3 Balance Platinum Ribbon Kit* N5370478 712<br />

1 4 Balance Tare Weight N5190284 110<br />

for TGA 7 High-Temperature<br />

1 4 Balance Tare Weight N5190282 110<br />

for TGA 7 Standard<br />

1 5 O-Ring, used under Balance Cover 09902163 25<br />

5 7/8 in. o.d. x 1/8 in. wide<br />

1 O-Ring, Ball Joint 09902131 10<br />

1 7/16 in. o.d. x 1/8 in. wide<br />

1 O-Ring, Split, used at TGA 7 09902031 3<br />

Standard Furnace Mount<br />

1 7/8 in. o.d. x 3/16 in. wide<br />

1 Fuse 09981785 4<br />

12 A, 250 V (Line Power)<br />

* PerkinElmer Service installation required.<br />

3<br />

6<br />

7<br />

8<br />

9<br />

4<br />

1<br />

2<br />

5<br />

Standard Furnace TGA<br />

TGA Supplies and Accessories Thermal Analysis<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

369


TGA Supplies and Accessories<br />

Furnace and Furnace Accessories<br />

Thermal Analysis TGA Supplies and Accessories<br />

TGA Accessories and Supplies<br />

PYRIS 1 TGA Accupik Replacement Needle Kit<br />

Contains 3 needles.<br />

PYRIS 1 TGA Cooling Jacket<br />

With this accessory and C 6<br />

Chiller (optional), the TGA<br />

can start from -20 °C.<br />

PYRIS TGA Volatile Sealer Tool<br />

PYRIS TGA Volatile<br />

Capsule Sealer Kit<br />

Tube Clamp for PYRIS 1 TGA<br />

3/8 in. diameter.<br />

Antistatic Compound, Liquid<br />

Apply to the outside of the glassware<br />

to reduce static electricity.<br />

Static Discharge Kit, TGA Furnace<br />

Includes conductive tube, conductive<br />

grease, gasket, O-Ring, and instructions.<br />

Designed for labs prone to static problems.<br />

TGA Furnace Conductive Tube<br />

Forceps, Non-Magnetic<br />

Description Part No. Each (€)<br />

Hooked 09908138 66<br />

Straight 09908400 60<br />

Antistatic Compound, Liquid<br />

for TGA 7 High-Temperature<br />

Apply to the outside of the glassware<br />

to reduce static electricity.<br />

100 mg Calibration Weight<br />

for TGA 1 and PYRIS 1 TGA<br />

Part No.<br />

Part No.<br />

Each (€)<br />

N5370552 568<br />

Part No.<br />

Each (€)<br />

N5370555 204<br />

Part No.<br />

Each (€)<br />

09903011 3<br />

Part No.<br />

Each (€)<br />

09905932 65<br />

Part No.<br />

Each (€)<br />

N5190512 2949<br />

Part No.<br />

Each (€)<br />

N5191552 2621<br />

Part No.<br />

Each (€)<br />

09905932 65<br />

Part No.<br />

Each (€)<br />

N5370554 210<br />

Part No.<br />

Each (€)<br />

N5370553 1518<br />

Each (€)<br />

09908397 153<br />

370


TGA Supplies and Accessories<br />

Hangdown Wires, Sample Pans, and Supplies<br />

Hangdown Wire Kits<br />

6<br />

7<br />

7<br />

7<br />

8<br />

TGA 7 Standard TGA 7 High Temperature PYRIS 1 TGA Standard PYRIS 1 TGA High Temperature<br />

Description Material Qty. Part No. Each (€) Part No. Each (€) Part No. Each (€) Part No. Each (€)<br />

Hangdown Wire Link Kit Quartz 10 N5190330 217<br />

Hanger Kit Quartz 5 N5370487 263<br />

Autosampler Hanger Kit Quartz 5 N5370488 275<br />

Hangdown Wire Kit Nichrome 6 N5190285 306<br />

Includes 6 preformed and 6 straight wires<br />

Hangdown Wire Kit Nichrome 6 N5190516 140<br />

Includes 6 preformed wires<br />

Hangdown Wire Kit Nichrome 6 N5190515 124<br />

Includes 6 straight wires<br />

Autosampler Hanger Kit Nichrome 5 N5370490 101<br />

Hanger Kit Platinum 6 N5370330 409<br />

Hangdown Wire Kit Platinum 6 N5190276 414<br />

Includes 6 preformed wires<br />

Stirrup Kit Platinum 4 03190265 536 N5190279 548 03190265 536 N5190279 548<br />

Nichrome Hangdown Wire Kit<br />

Part No. N5190285<br />

Quartz Hangdown Wire Link Kit<br />

Part No. N5190330<br />

Platinum Stirrup Kit<br />

Part No. 03190265<br />

Platinum Hangdown Wire Kit<br />

Part No. N5190276<br />

6<br />

7<br />

8<br />

High-Temperature Furnace TGA<br />

TGA Supplies and Accessories Thermal Analysis<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

371


TGA Supplies and Accessories<br />

Hangdown Wires, Sample Pans, and Supplies<br />

Thermal Analysis TGA Supplies and Accessories<br />

Sample Pans, Covers, and Supplies<br />

Platinum Sample Pan Kits<br />

9<br />

9<br />

Description Part No. Each (€)<br />

Sample Pan Kit 03190264 772<br />

for TGA 7 Standard/PYRIS 1 TGA,<br />

Includes 4 pans<br />

Sample Pan Kit N5190280 1149<br />

for TGA 7/PYRIS 1 TGA<br />

High-Temperature, Includes 4 pans<br />

Gold Volatile Pans and Covers<br />

for TGA 7/PYRIS 1 TGA<br />

For use with the TGA 7 or PYRIS 1 TGA (after making a<br />

pinhole) from room temperature to 1000 °C with gold pans<br />

for maintenance of vapor phase over sample. Requires<br />

Sample Sealer Assembly (02190061) for sealing or Universal<br />

Crimper Press (B0139005), with<br />

Sealing Insert (B0144637). 10 of each. Part No. Each (€)<br />

Aluminum Vapor Pressure Pan Kit<br />

for TGA 7/PYRIS 1 TGA<br />

This kit includes 100 volatile aluminum pans and 100<br />

pierced covers. A 50-micron diameter hole is centered in<br />

the cover. Use this kit for more reproducible measurements<br />

of boiling points, heats of vaporization, and sublimation<br />

temperatures. Vapor pressure studies can be conducted<br />

when using these pans and covers with the High Pressure<br />

DSC or the TGA. Maximum temperature is 600 °C. Requires<br />

Sample Sealer Assembly (02190061) for sealing or Universal<br />

Crimper Press (B0139005) with<br />

Sealing Insert (B0144637). 100 of each. Part No. Each (€)<br />

PYRIS 1 TGA Accupik Sample Pan and Covers<br />

Maximum temperature is 600 °C.<br />

400 pieces.<br />

Platinum Sample Pan Kit<br />

Part No. 03190264<br />

02190080 1078<br />

N5190788 300<br />

Part No.<br />

Each (€)<br />

N5370550 529<br />

Ceramic Liner Kit for TGA 7/PYRIS 1 TGA<br />

High-Temperature Sample Pans.<br />

Includes 6 covers and 6 liners.<br />

PYRIS 1 TGA Autosampler Ceramic Crucible Kit<br />

Contains 10 ceramic crucibles.<br />

Part No.<br />

PYRIS 6 TGA Sample Pans and Accessories<br />

Each (€)<br />

N5190283 644<br />

Part No.<br />

Each (€)<br />

N5370464 163<br />

Description Part No. Each (€)<br />

Sample Pan Kit for TGA 6 N5200040 118<br />

PYRIS 6 TGA Sample Holder N5203020 332<br />

Sample Pan Kit for TGA 6<br />

Part No. N5200040<br />

372


Thermal Analysis Software<br />

PYRIS Software<br />

PYRIS Series Advanced Software<br />

Additional Data Processing Power to Handle<br />

Your Laboratory’s Demanding Tasks<br />

A variety of thermal analysis software packages are<br />

available from PerkinElmer to allow you to perform specific<br />

tasks. Whether you need to determine absolute purity or<br />

kinetic parameters that characterize a reaction process, we<br />

have the software to handle the job.<br />

Temperature Dependent Crystallinity Software<br />

for PYRIS Users<br />

Contains the program disks and installation instructions. This<br />

version is for use directly from PYRIS Software for Windows<br />

without the need for manual conversion<br />

of the ASCII data files. Does not contain<br />

a separate security holder.<br />

Part No.<br />

N5370637<br />

Each (€)<br />

332<br />

DSC and DTA Kinetics Software<br />

Use these packages to obtain the kinetic parameters that<br />

characterize thermally initiated reactions. These programs<br />

use multilinear Regression Analysis (for the 7 Series and<br />

the 7 Series/UNIX software only). Contact your local<br />

salesperson for available options.<br />

Description Part No. Each (€)<br />

PYRIS DSC Scanning Kinetics Software (Single-user) N5370667 2627<br />

PYRIS DSC Isothermal Kinetics Software (Single-user) N5370668 2627<br />

PYRIS DSC Advanced Software Suite (Single-user) N5370610 4256<br />

PYRIS Model Free Kinetics (MFK) Software (Single-user) N5370638 1064<br />

TGA Decomposition Kinetics Software<br />

Allows calculation of the kinetics constants from multiple<br />

heating rate TG curves using from three to six data curves.<br />

Contact your local salesperson for available options.<br />

Description Part No. Each (€)<br />

PYRIS Model Free Kinetics (MFK) Software (Single-user) N5370638 1064<br />

PYRIS TGA Decomposition Kinetics (Single-user) N5370669 2627<br />

PYRIS TGA Advanced Software Suite (Single-user) N5370616 3192<br />

Includes: PYRIS 1 TGA and Diamond TG/DTA<br />

Decomposition Kinetics and PYRIS 1 TGA<br />

AutoStepwise Advanced Software<br />

DSC/TGA<br />

PYRIS Advanced Kinetics Software Suite (Single-user) N5370647 3724<br />

PYRIS Advanced Kinetics Software Suite (2+users) N5370648 1436<br />

Includes: PYRIS Series DSC Scanning Kinetics,<br />

DSC Isothermal Kenetics, DSC/TGA MFK, TGA<br />

Decomposition Kinetics<br />

PYRIS DSC Step Scan Software<br />

The PYRIS StepScan software provides the ability to<br />

determine accurate specific heat capacity (Cp) under a<br />

variety of conditions. StepScan produces a temperature<br />

program that consists of a series of short temperature steps.<br />

After each step, the heat flow is equilibrated until a criterion<br />

is satisfied, and then the next step is started. This produces<br />

a series of peaks. Available for both Diamond DSC and the<br />

PYRIS 1 DSC. It requires the PYRIS<br />

Software v3.7 or above.<br />

Part No. Each (€)<br />

PYRIS Series DSC Specific Heat Advanced Software<br />

(Single-User )<br />

Because the PYRIS 1 DSC and the DSC 7 provide a linear<br />

energy measurement over a wide temperature range, the<br />

two-curve Specific Heat Software allows the user to run a<br />

baseline and sample to calculate the Cp and enthalpy<br />

change of the sample. The three-curve method enables the<br />

analyst to be consistent with ASTM Method 1269E which<br />

requires sample, baseline, and reference runs for analysis of<br />

Cp and enthalpy change of the sample. Includes: one-, two-,<br />

and three-curve Specific Heat calculation<br />

capability for use on a single PC. Part No. Each (€)<br />

PYRIS Series DSC Purity Advanced Software<br />

(Single-User )<br />

N5370679 3192<br />

N5370665 2660<br />

This software package enables the analyst to determine the<br />

absolute purity of a sample. It also can identify the sample<br />

purity even if the sample decomposes during melting. The<br />

ideal melting point and the actual melting point may also be<br />

calculated. A Van’t Hoff plot is calculated and displayed by<br />

the software. The heat of fusion and melting point depression<br />

can be determined. Includes: one-, two-,<br />

and three-curve Specific Heat calculation Part No. Each (€)<br />

capability for use on a single PC.<br />

N5370666 3290<br />

PYRIS Enhanced Security Software (Single-User )<br />

In response to 21 CFR Part 11 and the increasing data<br />

security requirements in other industries, PerkinElmer’s<br />

PYRIS Enhanced Security TM (ES) option offers the<br />

technical compliance tools needed<br />

to meet these mandatory regulations. Part No. Each (€)<br />

N5370680 3192<br />

Thermal Analysis Software Thermal Analysis<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

373


Thermal Analysis Software<br />

PYRIS Software<br />

Thermal Analysis Thermal Analysis Software<br />

PYRIS Series Thermal<br />

Analysis Manager Software<br />

PYRIS Series Thermal Analysis Manager<br />

(Single-User )<br />

For control and operation of up to<br />

eight thermal analyzers of any type<br />

from a single PC controller.<br />

PYRIS Series Thermal Analysis<br />

Manager Additional Licenses<br />

(2-10 )<br />

PYRIS Series Multi-User IC License<br />

For those customers that require additional instrument<br />

control of their thermal analyzers from remote locations,<br />

such as in different laboratories<br />

within one facility, order one for<br />

each additional license.<br />

Part No.<br />

N5370606<br />

Each (€)<br />

1064<br />

PYRIS Series TMA/DMA<br />

Advanced Software<br />

PYRIS Series DMA 7/7e Advanced Software Suite<br />

(Single User )<br />

All DMA 7/7e Advanced Software Packages listed below are<br />

included for use on a single PC. Includes: DMA Frequency<br />

Scan Advanced Software (N5370674), DMA Dynamic Stress<br />

Scan Advanced Software (N5370675), DMA Frequency<br />

Multiplexing Advanced Software (N5370673), DMA Time/<br />

Temperature Superposition Advanced Software (N5370676),<br />

TMA/DMA Static Stress Scan Advanced<br />

Software (N5370671), TMA/DMA Creep<br />

Part No. Each (€)<br />

Recovery Advanced Software (N5370672). N5370622 7700<br />

PYRIS Series DMA 7/7e Advanced<br />

Software Suite Additional Licenses<br />

PYRIS Series DMA 7/7e<br />

Frequency Multiplexing Software<br />

Part No.<br />

Each (€)<br />

N5370600 6200<br />

Part No.<br />

Each (€)<br />

N5370603 186<br />

Part No.<br />

Each (€)<br />

N5370623 213<br />

This software enables the analyst to easily set up in one<br />

method a series of DMA Frequency Scans at different<br />

temperatures. This type of method<br />

is well-suited for Time/Temperature<br />

Superposition analysis.<br />

Part No.<br />

N5370673<br />

Each (€)<br />

3192<br />

PYRIS Series TMA/DMA Static Stress Scan Software<br />

In static stress scan mode, the static stress applied to the<br />

sample material is programmed over a specific range with<br />

time. Temperature is held constant and there is no dynamic<br />

component. Stress-dependent behavior is characterized by<br />

monitoring changes in strain. This mode<br />

is useful for the evaluation of the stress<br />

dependence of a physical structure.<br />

Part No.<br />

N5370671<br />

Each (€)<br />

3192<br />

PYRIS Series DMA Time/Temperature<br />

Superposition Software<br />

This analytical package utilizes data generated from frequency<br />

scans or Frequency Multiplex scans. A master curve is created<br />

(superimposed) from a series of frequency scans at different<br />

temperatures. The master curve is based on the WLF<br />

(Williams-Landell-Ferry) equations. A master curve is used to<br />

predict long-term mechanical behavior of a material. This is<br />

particularly applicable to amorphous,<br />

Part No. Each (€)<br />

linear, and cross-linked polymers as<br />

well as other materials.<br />

N5370676 3192<br />

PYRIS Series TMA 7 Advanced Software Suite<br />

(Single-User )<br />

All TMA 7 Advanced Software Packages listed below are<br />

included for use on a single PC. Includes: TMA/DMA Static<br />

Stress Scan Advanced Software<br />

(N5370671), TMA/DMA Creep Recovery<br />

Advanced Software (N5370672).<br />

Part No.<br />

N5370619<br />

Each (€)<br />

4256<br />

PYRIS Series TMA 7 Advanced<br />

Software Suite Additional Licenses<br />

Part No.<br />

Description Part No. Each (€)<br />

PYRIS DSC Advanced Software Suite (Single-user) N5370610 4256<br />

PYRIS DSC Advanced Software Suite (2+users) N5370611 1436<br />

PYRIS Series DMA 7/7e Frequency Scan Software<br />

Allows you to operate the DMA in a frequency scan mode<br />

where the frequency of oscillation is programmed over a<br />

specific and continuous range with time. Both temperature<br />

and stress are held constant in this mode. Rate-dependent<br />

behavior is characterized by monitoring the change in strain<br />

and phase over time. The frequency scan<br />

mode is a valuable tool for characterizing<br />

Part No. Each (€)<br />

or fingerprinting materials.<br />

N5370674 3192<br />

PYRIS Series DMA 7/7e Creep-Recovery Software<br />

Each (€)<br />

N5370620 213<br />

Use the Creep-recovery software to instantaneously apply<br />

a stress and hold it at the programmed constant value for<br />

a programmed time, and then instantaneously remove the<br />

stress. Time and stress-dependent behavior is characterized<br />

by monitoring the strain. Compliance, modulus, and stress<br />

are calculated and displayed on the screen as a Retardation<br />

Spectrum. The creep-recovery mode is used to generate<br />

modulus and viscosity values at long times (very low<br />

frequencies) that are not within practical limits of instrumental<br />

testing. A programmed ramped static<br />

force is now available as part of each<br />

Part No. Each (€)<br />

package for mechanical hysteresis. N5370672 2660<br />

PYRIS Series DMA 7/7e Dynamic Stress Scan Software<br />

In the Dynamic Stress Scan mode, the dynamic stress applied<br />

to the sample material is programmed over a specific range<br />

with time. Temperature and frequency are held constant.<br />

Stress-dependent behavior is characterized by monitoring<br />

changes in strain. This mode is useful for the evaluation of<br />

the stress dependence of a physical structure. It is also used<br />

to aid in the selection of the stress<br />

parameter used in the other DMA 7<br />

Part No. Each (€)<br />

modes of operation.<br />

N5370675 3192<br />

374


Ultramicrobalance Supplies<br />

Weights, Forceps, Stirrups, and Pans<br />

AD-6 Ultramicrobalance<br />

Provides highly accurate weighing of your samples<br />

Features a maximum sensitivity of 0.1 μg<br />

and a capacity of 5.0 g<br />

Allows easy access to the weighing chamber for both<br />

right-and left-handed analysts<br />

Communicates your results to a printer or a computer<br />

via an optional RS-232C interface<br />

Designed for high-performance weighing procedures<br />

Microcomputer controlled<br />

Autobalance Accessory Kit<br />

Includes non-magnetic stainless steel forceps, tare weight set,<br />

Class M calibrating weight, flat<br />

sample pans, and spare fuses.<br />

Part No. Each (€)<br />

Forceps<br />

Product Part No. Each (€)<br />

Non-Magnetic, Nonserrated Stainless Steel Straight 09908400 60<br />

Non-Magnetic, Hooked 09908138 66<br />

Manuals<br />

Product Part No. Each (€)<br />

Autobalance Quick Reference Guide 09937138 48<br />

AD-6 Instruction Manual C0991141 65<br />

Repair Kit<br />

Hangdown Wire Repair Kit<br />

Use to repair one wire for the<br />

AD-2/AD-4/AD-6 Balance.<br />

Sample Pans<br />

Product Pkg. Part No. Each (€)<br />

Aluminum Flat Pans<br />

For Standard Stirrup Kit 20 C3221027 99<br />

Stirrup Kit<br />

Standard Stirrup Kit<br />

Includes two matched stirrups.<br />

Weight and Weight Sets<br />

03220067 429<br />

Part No.<br />

Each (€)<br />

C3220112 125<br />

Part No.<br />

Each (€)<br />

03220068 179<br />

Description Part No. Each (€)<br />

Class 1.1 Calibrating Weight (per ASTM E617,100 mg) 09908397 153<br />

Tare Weight Set 09908396 56<br />

Includes: 13 weights ranging from 1 mg to 1 g<br />

AD-6 Ultramicrobalance<br />

Non-Magnetic,<br />

Nonserrated Stainless<br />

Steel Straight Forceps<br />

Part No. 09908400<br />

Tare Weight Set<br />

Part No. 09908396<br />

Standard Stirrup Kit<br />

Part No. 03220068<br />

Non-Magnetic, Hooked Forceps<br />

Part No. 09908138<br />

Aluminum Flat Pans<br />

Part No. C3221027<br />

Part No. C3221047<br />

Class 1.1 Calibrating Weight<br />

Part No. 09908397<br />

Ultramicrobalance Supplies Thermal Analysis<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

375


®


PerkinElmer has been an industry leader in UV/Vis/NIR and UV/Vis instrumentation for almost<br />

50 years, and we continue to innovate with our LAMBDA Series of spectrophotometers,<br />

with exclusive features such as the Universal Reflectance Accessory (URA). Offering sampling<br />

flexibility and superior data quality, PerkinElmer instruments are the standard in thousands of<br />

laboratories, in multiple industries worldwide.<br />

The LAMBDA 25/35/45 UV/Vis spectrophotometers increase productivity by generating<br />

accurate results the first time, every time. The new high-performance LAMBDA 950, 850<br />

and 650 UV/Vis/NIR and UV/Vis spectrophotometers deliver high performance, flexibility<br />

and convenience. Each model includes the same range of modular components and snap-in<br />

accessories to tackle a range of tough applications. These LAMBDA systems are easy to<br />

operate and deliver results you can trust, and are supported by the worldwide service and<br />

support of PerkinElmer.<br />

UV Visible


UV Visible<br />

QUICK-FIND INDEX Page #<br />

Calibration Reference<br />

Materials 395<br />

Cell Changers and<br />

Accessories 387<br />

Cell Holders 388<br />

Cells for Spectroscopy 390<br />

Cylindrical Cells 391<br />

Deuterium and Tungsten<br />

Source Lamps 397<br />

Fiber Optic Accessories 380<br />

Flow-through Cells 391<br />

General Purpose Optical<br />

Bench Kits 380<br />

Integrating Sphere Accessories 381<br />

Macro Cells 392<br />

Micro Cells 393<br />

Polarimetry Supplies 399<br />

Polarizer/Depolarizer<br />

Accessories 382<br />

Research Peltier System 386<br />

Routine Peltier Systems 385<br />

Semi-micro Cells 393<br />

Sippers and Sipper<br />

Accessories 382<br />

Specular Reflectance<br />

Accessories 384<br />

PerkinElmer offers a wide selection of superior quality products designed to work with<br />

your PerkinElmer instruments. Our precision-designed products deliver the peace of<br />

mind that comes from knowing that you’ll get the results you need.<br />

The Quick Find Index to the left will help you find products fast. For your convenience,<br />

products are alphabetized by category, sub-category, and family. There is also a more<br />

complete Alphabetical INDEX on page 429 and a Part Number INDEX on page 407.<br />

Deuterium and Tungsten Source Lamps<br />

Cells for Spectroscopy<br />

Calibration Reference Materials<br />

For optimum instrument performance, always use original<br />

replacement Source Lamps from PerkinElmer. Our extensive<br />

quality control and inspection process ensures the very<br />

best quality sources. This guarantees top performance and<br />

maximum stability from your UV/Vis Spectrophotometer.<br />

Page 397<br />

PerkinElmer cells ensure top optical performance, with high<br />

cell transmission and accurate pathlength. The cell windows<br />

are fused to the bodies by a special process which avoids<br />

deformation of the windows. This assures that the full<br />

width of the cell is usable and the finished cell dimensions<br />

are maintained.<br />

Page 390<br />

PerkinElmer Reference Materials speed calibration<br />

verification of UV/Vis and UV/Vis/NIR Spectrophotometers,<br />

providing laboratory managers with the evidence they need<br />

to pass the strictest quality audit. A USA-based calibration<br />

laboratory ensures a reliable two-week turnaround service<br />

for periodical recalibrations.<br />

Page 395<br />

Ultra-micro Cells 394<br />

UV/Vis Software 398<br />

8+1 Cell Changer<br />

A range of automatic linear cell changers speeds and<br />

simplifies multi-sample measurements and quantitative<br />

calibrations. The 8+1 Cell Changer is an automatic water<br />

thermostattable, automatic linear cell changer, for eight<br />

samples and one reference. It includes the Automatic<br />

Linear Transport, 8-Cell Holder Water Thermostattable and<br />

Water Thermostattable Reference Cell Holder.<br />

Page 387


LAMBDA Spectrophotometers<br />

Proven Technology that Delivers<br />

Consistently High Quality Results<br />

PerkinElmer provides a range of UV/Vis and<br />

UV/Vis/NIR spectrophotometers, software,<br />

sampling accessories and services to help<br />

you improve product quality, productivity<br />

and analytical processes.<br />

LAMBDAs are the preferred choice of busy teaching, materials<br />

research and bio-research laboratories, where the PerkinElmer<br />

name is synonymous with quality, performance and reliability.<br />

LAMBDA 950<br />

LAMBDA 25/35/45<br />

PerkinElmer’s Lambda TM 25/35/45 UV/Vis<br />

systems increase productivity by mimicking<br />

the QA workflow to generate high quality<br />

results the first time, every time. The<br />

Lambda systems are easy to operate and<br />

deliver results you can trust with the<br />

minimum of operator training – it’s easy<br />

to develop simple, robust methods and<br />

ensure they’re followed without mistakes.<br />

With more than 10,000 units installed<br />

world-wide our superior technology and<br />

build quality has proven itself under the<br />

toughest conditions.<br />

Features:<br />

■ True double-beam operation provides the best<br />

possible stability and allows references to be<br />

measured and corrected in real-time<br />

■ Sealed and quartz coated high throughput optics<br />

ensure consistently high performance throughout<br />

the instrument’s service life<br />

LAMBDA 950, 850, and 650<br />

The new LAMBDA 950, 850, and 650<br />

UV/Vis/NIR and UV/Vis spectrophotometers<br />

are the industry standard for high<br />

performance, flexibility and convenience.<br />

Each model includes the same range<br />

of modular components and snap-in<br />

accessories to tackle a range of<br />

tough applications.<br />

LAMBDA 650<br />

The LAMBDA 650 is an upgradeable,<br />

flexible UV/Vis system at a cost-effective<br />

price. This system is for high performance<br />

measurements between 190 and 900 nm.<br />

Applications include color analysis of<br />

paints and textiles, turbid solutions,<br />

and enzyme kinetics in life science,<br />

biochemistry, and pharmaceutical<br />

laboratories. The LAMBDA 650 can be<br />

upgraded for higher sampling. A 150 mm<br />

integrating sphere is included for ASTM,<br />

CIE, and DIN measurements.<br />

LAMBDA 850<br />

The LAMBDA 850 is our highest<br />

performance UV/Vis system. Choose this<br />

model for ultra-high UV/Vis performance<br />

for wavelengths between 175 and 900 nm,<br />

for applications such as sun protection,<br />

reflectance properties of flat panel display<br />

screens, paint films, transmission and<br />

reflectance characterization of glass<br />

and solar cells.<br />

LAMBDA 950<br />

The LAMBDA 950 is our highest<br />

performance UV/Vis/NIR System. Choose<br />

this model for ultra-high UV/Vis/NIR<br />

performance for wavelengths up to<br />

3,300 nm, high precision measurements,<br />

and for applications such as highly<br />

reflective and anti-reflective coatings,<br />

color correction coatings, bandpass<br />

characteristics of UV, Vis, and NIR filters,<br />

and more.<br />

379


Accessories<br />

Fiber Optic and General Purpose Optical Bench Accessories<br />

Autosampler Supplies<br />

and Accessories for UV<br />

Please see pages 8-9 for our full selection of Sample Trays, Sample Vessels,<br />

Probes, Tubing, and Accessories for the AS93plus Autosampler.<br />

Fiber Optics Accessories<br />

Light Shield<br />

For use with Fiber Optic Dip Probe (N1016070).<br />

LAMBDA Model Part No. Each (€)<br />

All N1016074 437<br />

Probe Tip<br />

For use with Fiber Optic Dip Probe (N1016070).<br />

UV Visible Accessories<br />

Transfer-Optic for 1X/2X/3X/4X/Bio Part No. B0509546<br />

Transfer-Optic for Mono-Fibers<br />

Fiber optic transfer holder for LAMBDA spectrophotometers.<br />

Requires pair of Mono-Fibers 2x2 or 2x10 meters and/or<br />

optrode. Other optrodes available on request<br />

LAMBDA Model Part No. Each (€)<br />

1X/2X/3X/4X/Bio B0509546 2129<br />

650/850/950 L6020290 2505<br />

800/900 B2205302 4512<br />

Pair of Mono-Fibers<br />

2x2 meters each.<br />

Wavelength Part No. Each (€)<br />

250 to 900 nm (UV/Vis) B0196912 2895<br />

400 to 2400 nm (Vis/NIR) B0509591 2012<br />

Fiber Optic Dip Probe<br />

The Fiber Optic Dip Probe is a 15 mm, 316 grade stainless<br />

steel probe with a wavelength of 200-1100 nm. Requires<br />

but does not include, Transfer-Optic for Mono-Fibers,<br />

Light Shield (N1016074), and one of the following Probe<br />

Tips: Probe Tip, 2 mm pathlength (N1016073); Probe Tip,<br />

5 mm pathlength (N1016072); or Probe Tip, 10 mm<br />

pathlength (N1016071).<br />

LAMBDA Model Part No. Each (€)<br />

All N1016070 1675<br />

Pathlength Part No. Each (€)<br />

2 mm N1016073 556<br />

5 mm N1016072 616<br />

10 mm N1016071 682<br />

General Purpose Optical Bench Kits<br />

for the LAMBDA 6XX/8XX/9XX<br />

Sample Holder Mount Kit<br />

Two cantilever sample holders<br />

with magnetic bases.<br />

Variable Angle Transmittance Sample Holder Kit<br />

Holds samples at an accurately measured angle to the<br />

incident beam for measurement of<br />

transmittance. Samples can be up<br />

to 1 cm thick and up to 10 cm square.<br />

Part No.<br />

PELA1006<br />

Each (€)<br />

1579<br />

Optical Bench Kit<br />

Two magnetized mounted iris<br />

diaphragms on two optical<br />

rails with mounts.<br />

Short Focal Length Mirror Kit, Spot Incidence<br />

Kit consists of a short focal length (20 to 30 mm) concave<br />

mirror on an adjustable base with<br />

magnetic mounts to allow for small<br />

spot incidence of curved samples.<br />

Part No.<br />

PELA1013<br />

Each (€)<br />

975<br />

Beam Blocker Kit<br />

Optical black beam blocker on<br />

adjustable base with magnetic mounts.<br />

Fiber Optic Measurement Stage and Holder Kit<br />

Includes two fiber optic holders to<br />

allow for measurement of small<br />

diameter fibers and fixed apertures.<br />

Part No.<br />

Each (€)<br />

PELA1005 1208<br />

Part No.<br />

Each (€)<br />

PELA1008 2010<br />

Part No.<br />

Each (€)<br />

PELA1014 329<br />

Part No.<br />

Each (€)<br />

PELA1015 6100<br />

380


Accessories<br />

Integrating Sphere Accessories<br />

Biconical Accessory Small Spot Size (Praying Mantis) Part No. PELA1022<br />

Biconical Accessory Small Spot Size (Praying Mantis)<br />

For diffuse reflectance measurement with horizontal sample<br />

position for powders, pastes, and granulates. Provides a<br />

very small spot size.<br />

LAMBDA Model Wavelength Range Part No. Each (€)<br />

1X/2X/3X/4X/Bio 200 to 1100 nm C6950209 8700<br />

6XX/8XX/9XX 200 to 3300 nm PELA1022 11000<br />

Variable Angle Transmittance Sample Holder<br />

of Non-Scattering Samples<br />

Includes sample holder and manual rotary stage<br />

cinematically positioned in front of the sphere.<br />

LAMBDA Model Part No. Each (€)<br />

6XX/8XX/9XX PELA9042 2165<br />

Center Mounted Sample Holder, Clip Style<br />

Part No. PELA9039<br />

Center Mounted Sample Holder, Clip Style<br />

For 150 mm integrating spheres. Clip style for films<br />

and paper samples.<br />

LAMBDA Model Part No. Each (€)<br />

6XX/8XX/9XX PELA9039 3185<br />

Center Mounted Sample Holder, Jaw Style<br />

For 150 mm integrating spheres. Jaw style for solid<br />

samples like glasses, prisms, etc.<br />

LAMBDA Model Part No. Each (€)<br />

6XX/8XX/9XX PELA9038 3913<br />

Cell Holder for 150 mm Integrating Sphere<br />

For measurement in 1 cm cuvettes in transmission<br />

or reflectance mode.<br />

LAMBDA Model Part No. Each (€)<br />

6XX/8XX/9XX C6951019 185<br />

Small Spot Accessory Kit<br />

for 150 mm Integrating Sphere<br />

Lens kit for reducing beam size to the transmittance, to<br />

the center mount, and to the diffuse reflectance position.<br />

LAMBDA Model Part No. Each (€)<br />

6XX/8XX/9XX L6020211 9100<br />

Accessories UV Visible<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

381


Accessories<br />

Polarizer/Depolarizer Accessories<br />

Polarizer/Depolarizer and Accessories<br />

for the LAMBDA 6XX/8XX/9XX<br />

Common Beam Depolarizer<br />

for LAMBDA 6XX/8XX/9XX<br />

For measurements with depolarized light. Wavelength<br />

range: 190 to 2600 nm. Setup with stepper drive, controlled<br />

by UV WinLab TM software.<br />

Service installation required.<br />

Part No. Each (€)<br />

B0501282 3373<br />

Polarizer/Depolarizer Crystals<br />

for the LAMBDA 6XX/8XX/9XX<br />

High Performance Polarizer Crystal<br />

for LAMBDA 6XX/8XX/9XX Double Polarizer Drive<br />

High performance polarizer. One set to update the Double<br />

Polarizer Drive. For equal energy level in sample and<br />

reference beam, two Crystals are necessary.<br />

Wavelength range: 300 to 2600 nm. Part No. Each (€)<br />

B0505284 8100<br />

UV Visible Accessories<br />

Double Polarizer Drive Part No. B0505530<br />

Double Polarizer Drive for LAMBDA 6XX/8XX/9XX<br />

High performance double polarizer (depolarizer) driver for<br />

installation in the sample compartment. The polarization<br />

(depolarization) orientation can be fully automated,<br />

changed by a scan at a fixed wavelength or with a stepping<br />

mode. Resolution of 0.25° for scanning. The polarization<br />

(depolarization) orientation in the<br />

stepping mode can be changed at Part No. Each (€)<br />

up to 20 wavelength positions.<br />

B0505530 1106<br />

Requires, but does not include, one or two of the following<br />

polarization elements:<br />

Description Part No. Each (€)<br />

High Performance Polarizer Crystal B0505284 8100<br />

Film Polarizer B2205022 688<br />

Depolarizer Crystal B2205021 2931<br />

Glan-Taylor Polarizer Crystal N1010520 2285<br />

Film Polarizer for LAMBDA 6XX/8XX/9XX<br />

Double Polarizer Drive<br />

High performance film polarizer. One part to update the<br />

Double Polarizer Drive. For equal energy level in sample<br />

and reference beam, two Crystals are necessary. Wavelength<br />

range: 400 to 700 nm. Other wavelength<br />

ranges available on request.<br />

Part No. Each (€)<br />

B2205022 688<br />

Glan-Taylor Polarizer Crystal<br />

for LAMBDA 6XX/8XX/9XX Double Polarizer Drive<br />

Mounted 15 mm Glan-Taylor polarizer. For equal energy<br />

level in sample and reference beam,<br />

two Crystals are necessary. Wavelength<br />

range: 210 to 1000 nm.<br />

Part No.<br />

N1010520<br />

Each (€)<br />

2285<br />

Depolarizer Crystal for LAMBDA 6XX/8XX/9XX<br />

Double Polarizer Drive<br />

High performance depolarizer crystal for measurements in<br />

depolarized light in the sample compartment. One part to<br />

update the double polarizer drive. For equal energy level in<br />

sample and reference beam, two Crystals are necessary. The<br />

depolarizer crystals can be rotated at up to 20 wavelength<br />

points to get a wavelength<br />

independent depolarization.<br />

Part No. Each (€)<br />

Wavelength range: 190 to 2600 nm.<br />

B2205021 2931<br />

Sippers and Accessories<br />

Peristaltic Sipper “PESI”<br />

Sampling and purging time selectable from keyboard.<br />

For LAMBDA 25/35/45/10/20/40 no accessory PCB<br />

necessary. Requires, but does not include, accessory PCB<br />

for LAMBDA Bio 11, 12, and 14, (B0509681/B2190034) or<br />

accessory PCB for LAMBDA 18/19 (B0124984/B0116378).<br />

For LAMBDA 6XX/8XX/9XX, requires, but does not<br />

include, Installation Kit for LAMBDA 800/900 (B2500123)<br />

and Accessory PC Board for LAMBDA 800/900 (B2205116).<br />

Requires, but does not include, Flowcell<br />

of choice with screw connector.<br />

Part No.<br />

Each (€)<br />

B2190036 1256<br />

382


Accessories<br />

Sipper Accessories<br />

Sipper Cells<br />

Flow-Through Cell, 10 mm, with<br />

Two Screw Connectors<br />

10 mm pathlength, with two screw<br />

connectors, Quartz SUPRASIL ® ,<br />

160 μL cell volume.<br />

Part No. Each (€)<br />

B0631087 297<br />

Vacuum Sipper “VASI”<br />

Sampling and purging time selectable from keyboard.<br />

For LAMBDA 25/35/45/10/20/40 no accessory PCB<br />

necessary. Requires, but does not include, accessory PCB<br />

for LAMBDA Bio 11, 12 and 14 (B0509681/B2190034) or<br />

accessory PCB for LAMBDA 18/19 (B0124984/B0116378).<br />

Compatible with UV WinLab 2.8 or earlier only.<br />

For LAMBDA 6XX/8XX/9XX, requires, but does not<br />

include, Installation Kit for LAMBDA 800/900 (B2500123)<br />

and LAMBDA 800/900 Accessory PC Board (B2205116).<br />

Compatible with UV WinLab 3.0 or earlier only.<br />

Requires, but does not include, 110 V/60 Hz Pump Unit<br />

(B0505866) or 220 V/50 Hz Pump Unit (B0084183) and<br />

Flowcell of choice with screw connector.<br />

Description Part No. Each (€)<br />

Vacuum Sipper with Pinch Valve B2190037 1142<br />

Vacuum Sipper with Solenoid Valve B2190038 1675<br />

Pump Unit<br />

Vacuum pump with 1 L waste bottle. For use with sipper<br />

systems (or funnel cells).<br />

Power Requirement Part No. Each (€)<br />

120 V/60 Hz B0505866 831<br />

220 V/50 Hz B0084183 873<br />

Long Pathlength Flowcell, 50 mm,<br />

with Two Screw Connectors<br />

50 mm pathlength, with two screw<br />

connectors, Quartz, 370 μL<br />

cell volume.<br />

Micro Flowcell, 10 mm, with Nipple Connector<br />

10 mm pathlength, non-thermostatted,<br />

nipple connector, Quartz SUPRASIL,<br />

160 μL cell volume.<br />

Long Pathlength Micro Flowcell, 50 mm,<br />

with Nipple Connector<br />

50 mm pathlength, 4 mm circular<br />

chamber. Nipple connector, Quartz<br />

SUPRASIL, 600 μL cell volume.<br />

Sipper Tubing<br />

Tubing Kit for Peristaltic and Vacuum Sipper<br />

For Peristaltic Sipper “PESI”<br />

(B2190036), and Vacuum Sipper<br />

“VASI” with Pinch Valve (B2190037).<br />

Tubing Kit for Vacuum Sipper with Solenoid Valve<br />

For Vacuum Sipper “VASI” with<br />

Solenoid Valve (B2190038). For Micro<br />

Flowcells with screw connectors.<br />

Tygon Tubing for Peristaltic Pump (Purple/Purple)<br />

2.06 mm i.d. with a 0.80 mm<br />

wall thickness. (pkg. 12)<br />

Part No.<br />

Each (€)<br />

B0631088 659<br />

Part No.<br />

Each (€)<br />

B0191766 528<br />

Part No.<br />

Each (€)<br />

B0109944 869<br />

Part No.<br />

Each (€)<br />

B2500103 117<br />

Part No.<br />

Each (€)<br />

B0198023 117<br />

Part No.<br />

Each (€)<br />

B0199034 37<br />

Accessories UV Visible<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

383


Accessories<br />

Specular Reflectance<br />

Absolute Specular<br />

Reflectance Accessory<br />

Accessories for<br />

Specular Reflectance<br />

UV Visible Accessories<br />

VN Absolute Specular Reflectance Accessory Part No. N1016008<br />

VN Absolute Specular Reflectance Accessories<br />

for the LAMBDA 6XX/8XX/9XX Spectrophotometer<br />

The Absolute Specular Reflectance Accessory mounts in the<br />

standard sample compartment. It is used to produce absolute<br />

reflectance data on various types of surfaces. Both highly<br />

reflective and anti-reflective surfaces may be measured.<br />

When measuring a sample, only one light bounce from<br />

the sample surface is required. This provides the optimal<br />

s/n performance.<br />

Base Plate (N1016001) or the General Purpose Optical<br />

Bench Base Plate required. Use of Integrating Sphere<br />

Detector is recommended.<br />

Specifications:<br />

For measurements of absolute specular reflectance<br />

of filters, glasses, and mirrors<br />

Angle of Incidence: 8°, 15°, 30°, 45°, and 60°<br />

Typical Accuracy: Better than 1% reflectance when compared<br />

to a known commercially available standard (SRM 2003 etc.)<br />

Wavelength Range: 190 to 900 nm (LAMBDA 6XX),<br />

175 to 900 nm (LAMBDA 8XX), 175 to 3300 nm (LAMBDA 9XX)<br />

Sample Size: Minimum sample size ~ 2.5 cm<br />

Angle of Incidence Part No. Each (€)<br />

8° - Near Normal N1016008 5800<br />

15° N1016015 7200<br />

30° N1016030 7200<br />

45° N1016045 3394<br />

60° N1016060 3446<br />

Base Plate for VN Absolute Specular Reflectance<br />

Accessories for the LAMBDA 6XX/8XX/9XX<br />

Mother plate for the VN accessory suite.<br />

LAMBDA Model Part No. Each (€)<br />

6XX/8XX/9XX N1016001 2088<br />

Relative Specular Reflectance Accessory, 6° Part No. B0086703<br />

Relative Specular Reflectance Accessory, 6°<br />

For reflectance or thickness measurements.<br />

6° angle of light incidence.<br />

LAMBDA Model Part No. Each (€)<br />

All B0086703 2536<br />

Spare Standard Mirror<br />

For Relative Specular Reflectance Accessory, 6° (B0086703)<br />

and Variable Angle Reflectance Accessory (B0137314).<br />

This mirror is not calibrated.<br />

LAMBDA Model Part No. Each (€)<br />

All B0071519 159<br />

Powder Sample Holder Set<br />

For measurement of powder samples.<br />

LAMBDA Model Part No. Each (€)<br />

All PELA9040 682<br />

384


Accessories<br />

Thermostatting Accessories<br />

Routine Peltier Single Sample Accessory<br />

Peltier temperature controlled single cell holder for the<br />

sample position. Also included are a reference position<br />

cover, power supply, power cables, and User’s Guide.<br />

Selectable temperature range 20° to 45 °C. Requires the<br />

LAMBDA 25, 35, 45 Accessory Board (L6000500).<br />

LAMBDA Model Part No. Each (€)<br />

1X/2X/3X/4X/Bio B2000159 3148<br />

Routine Peltier Systems<br />

Routine Peltier System – Single Sample Accessory<br />

+ Single Reference Accessory<br />

Includes the Peltier Single Sample Accessory (B2000159)<br />

for the sample position and the Single Reference Accessory<br />

(B0510412) for the reference position. Also included are a<br />

reference position cover, power supply, power cables, and<br />

User’s Guide. Selectable temperature range 20° to 45 °C.<br />

Requires the LAMBDA 25, 35, 45 Accessory Board (L6000500).<br />

LAMBDA Model Part No. Each (€)<br />

1X/2X/3X/4X/Bio N1010565 3947<br />

Routine Peltier System – 9-Sample Position<br />

Accessory + Single Reference Accessory<br />

Includes the Peltier 9-Sample Position Accessory for<br />

the sample position and the Single Reference Accessory<br />

for the reference position. Also included are 5 beam<br />

masks, alignment gauge, reference position cover, sample<br />

compartment extension, power supply, cables, and User’s<br />

Guide. Selectable temperature range 20° to 45 °C. Must be<br />

service installed. Requires the LAMBDA 25, 35, 45<br />

Accessory Board (L6000500).<br />

LAMBDA Model Part No. Each (€)<br />

1X/2X/3X/4X/Bio N1010566 5400<br />

Routine Peltier 9-Sample Position Accessory<br />

Includes the Peltier 9 position cell changer, 5 beam masks,<br />

alignment gauge, reference position cover, sample compartment<br />

extension, power supply, power cables, and User’s Guide.<br />

Must be service installed. Selectable temperature range 20°<br />

to 45 °C. Requires the LAMBDA 25, 35, 45 Accessory<br />

Board (L6000500).<br />

LAMBDA Model Part No. Each (€)<br />

1X/2X/3X/4X/Bio B2000160 4555<br />

Routine Peltier Single Reference Accessory<br />

Peltier temperature controlled single cell holder for the<br />

reference position Also included are the power supply,<br />

power cables, and User’s Guide. Selectable temperature<br />

range 20° to 45 °C. Requires the LAMBDA 25, 35, 45<br />

Accessory Board (L6000500).<br />

LAMBDA Model Part No. Each (€)<br />

1X/2X/3X/4X/Bio B0510412 819<br />

9-Postion Cell Holder<br />

As included with the Peltier 9-Sample Position Accessory.<br />

Additional interchangeable cell holder for use with the<br />

9-position cell changer.<br />

LAMBDA Model Part No. Each (€)<br />

1X/2X/3X/4X/Bio B0510366 437<br />

Accessories UV Visible<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

385


Accessories<br />

Thermostatting Accessories<br />

Peltier Controlled Fluid Circulator (PCB-150)<br />

An external fluid circulator for use with all thermostatted<br />

cell holders enabling peltier effect temperature control.<br />

With both heating and cooling ability the circulator<br />

provides a temperature range of 20° to 60 °C with an<br />

accuracy of +/- 0.1 °C. Also included is a serial port<br />

and documentation to enable PC programming.<br />

LAMBDA Model Part No. Each (€)<br />

All N1015158 2840<br />

UV Visible Accessories<br />

Research Peltier<br />

System – 6 Position<br />

Part No. L6310011<br />

Research Peltier System<br />

Research Peltier System – Single Cell (PTP-1)<br />

For thermostatting of one rectangular cell in the sample<br />

beam. Temperature range 0° to 100 °C. Flexible programming<br />

of temperature ramps with up to 8 segments is possible.<br />

For thermostatting the reference cell holder, use Water<br />

Thermostatted Cell Holder (B0080819), not included.<br />

LAMBDA Model Part No. Each (€)<br />

All L6310010 3858<br />

Research Peltier System – 6 Position (PTP-6)<br />

For thermostatting of up to six rectangular cells in the sample<br />

beam, stirring possible. Temperature range 0° to 100 °C.<br />

Flexible programming of temperature ramps with up to<br />

8 segments is possible. Requires, but does not include,<br />

Automatic Linear Transport for LAMBDA 1X/2X/3X/4X/Bio<br />

(B2000186) or Linear Cell Programmer for LAMBDA<br />

6XX/8XX/9XX (B2205401).<br />

LAMBDA Model Part No. Each (€)<br />

All L6310011 6400<br />

Water Thermostatted Cell Holder<br />

A single cell holder with 3 mm fluid tubing connectors to<br />

enable fluid circulated temperature stabilization. Can be<br />

installed in the reference position with the PTP-1 and PTP-6<br />

to allow the reference sample to be temperature controlled.<br />

Requires, but does not include, a fluid circulator.<br />

LAMBDA Model Part No. Each (€)<br />

All B0080819 737<br />

Water Circulator, 220 V/50 Hz<br />

Electronic temperature control, continuously settable from<br />

20° to 65 °C, temperature stability +/- 0.2 °C, with precision<br />

thermometer and built-in cooling coils.<br />

LAMBDA Model Part No. Each (€)<br />

All B0080171 2143<br />

Water Circulator, 110 V/60 Hz<br />

Electronic temperature control, continuously settable from<br />

32° to 60 °C, temperature stability +/- 0.2 °C, with precision<br />

thermometer and built-in cooling coils.<br />

LAMBDA Model Part No. Each (€)<br />

All N9302736 1746<br />

Temperature Measurement Kit<br />

Probe for measuring the temperature within the cell.<br />

Includes glass cell. Requires the LAMBDA 25, 35, 45<br />

Accessory Board (L6000500).<br />

LAMBDA Model Part No. Each (€)<br />

1X/2X/3X/4X/Bio B0185227 472<br />

Magnetic Stirrer Accessory<br />

For 1-cell position. For single cell holders and cell changers.<br />

Power Requirements Part No. Each (€)<br />

110 V/60 Hz B0507355 778<br />

220 V/50 Hz B0510070 945<br />

Stirring Rods<br />

Set of 15 pieces for stirring in the cuvette. For use with<br />

Research Peltier System – 6 Position (PTP-6), (L6310011) and<br />

13-Cell Changer System (B0185210), and<br />

Magnetic Stirrer Accessory (B0507355). Part No. Each (€)<br />

B0187028 63<br />

386


Cells<br />

Cell Changers and Accessories<br />

Cell Changers for<br />

LAMBDA 1X/2X/3X/4X/Bio<br />

5+5 Cell Changer for LAMBDA 1X/2X/3X/4X/Bio<br />

Automatic linear 5+5 cell changer for long pathlength<br />

cells up to 50 mm. Includes: Automatic Linear Transport<br />

(B2000186), Reference Kit (B2000310), and two Long<br />

Pathlength 5-Cell Holders (B0089439).<br />

No accessory PCB required.<br />

Part No. Each (€)<br />

8+1 Cell Changer for LAMBDA 1X/2X/3X/4X/Bio<br />

Automatic water thermostattable automatic linear cell<br />

changer for eight samples and one reference. Includes:<br />

Automatic Linear Transport<br />

(B2000186), 8-Cell Holder<br />

Water Thermostattable<br />

(B2205411), and Water<br />

Thermostattable Reference<br />

Cell Holder (B2000201).<br />

No accessory PCB required.<br />

8+8 Cell Changer for LAMBDA 1X/2X/3X/4X/Bio<br />

13-Cell Changer System for LAMBDA<br />

1X/2X/3X/4X/Bio<br />

N1010569 3146<br />

Part No.<br />

Each (€)<br />

N1010567 2775<br />

Automatic water thermostattable automatic linear cell<br />

changer for eight samples and eight references. Includes:<br />

Automatic Linear Transport (B2000186), Reference Kit<br />

(B2000310), and two 8-Cell Holders<br />

(B2205411). No accessory PCB required. Part No. Each (€)<br />

N1010568 3266<br />

Includes cell changer and one carousel each for glass/quartz<br />

and plastic cuvettes. Accessory PCB (L6000500) required for<br />

LAMBDA 25/35/45, or PCB (B0509681)<br />

required for LAMBDA 10/20/40/Bio,<br />

but not included.<br />

Part No.<br />

B0185210<br />

Each (€)<br />

2966<br />

Manual Cell Changer for LAMBDA 1X/2X/3X/4X/Bio<br />

Base unit to be used with cell holder of choice. Includes<br />

Accessory Cover (B0094014). Requires, but does not<br />

include, Long Pathlength 5-Cell Holder<br />

(B0089439) or 8-Cell Holder, Water<br />

Thermostattable (B2500081).<br />

Part No.<br />

B2500080<br />

Each (€)<br />

945<br />

Automatic Linear Transport for LAMBDA<br />

1X/2X/3X/4X/Bio<br />

Automatic linear transport unit. Can be combined with<br />

8-Cell Holder, Water Thermostattable (B2205411), Long<br />

Pathlength 5-Cell Holders (B0089439), or Research Peltier<br />

System (L6310011). For reference position, Reference Kit<br />

(B2000310) and 5- or 8-Cell Holder recommended, but<br />

not included. Single Cell Reference<br />

Holder (B2000201) can be<br />

Part No. Each (€)<br />

used alternatively.<br />

B2000186 1711<br />

Reference Kit<br />

For Automatic Linear Transport (B2000186). For reference<br />

position to be used with 8-Cell Holder, Water Thermostattable<br />

(B2205411) or Long Pathlength<br />

5-Cell Holder (B0089439).<br />

Part No. Each (€)<br />

Gel-Scanner Linear Transport for Gels and Glasses<br />

for LAMBDA 1X/2X/3X/4X/Bio<br />

Complete Gel-Scanner accessory. Allows measurement<br />

of 100 mm gel cuvettes or glass samples up to 100 mm<br />

pathlength in continuous or random access mode.<br />

No accessory PCB required. For gel<br />

measurement, Gel Cell (B0107047)<br />

is required, but not included.<br />

Part No.<br />

B2000199<br />

Each (€)<br />

4019<br />

Gel Cell, Glass<br />

B2000310 359<br />

For gel measurements with Gel-Scanner Linear Transport<br />

(B2000199). Dimensions are 6 mm pathlength by 100 mm<br />

width by 10 mm height.<br />

Part No. Each<br />

(€)<br />

CP183700 251<br />

Cells UV Visible<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

387


Cells<br />

Cell Changers and Holders<br />

UV Visible Cells<br />

Cell Changers for LAMBDA 6XX/8XX/9XX<br />

9+9 Peltier Controlled<br />

Cell Programmer<br />

for LAMBDA<br />

6XX/8XX/9XX<br />

Spectrophotometers<br />

The accessory includes<br />

two sample trays with<br />

nine positions each. The following sample setup is possible:<br />

one reference cell and eight sample cells on either tray or<br />

nine cells on the sample tray and nine cells on the reference<br />

tray. For temperature control,<br />

Accessory PCB required (B2205116). Part No. Each (€)<br />

Temperature range 15° to 45 °C.<br />

B2205104 5500<br />

Linear Cell<br />

Programmer for<br />

LAMBDA 6XX/8XX/9XX<br />

UV/Vis/NIR<br />

Spectrophotometers<br />

Requires set of two cell<br />

holders of choice, either<br />

two Long Pathlength 5-Cell Holders (B0089439), or two 8-Cell<br />

Holders, Water Thermostattable (B2205411).<br />

Part No.<br />

Each (€)<br />

B2205401 3385<br />

Linear Transport<br />

and Gel-Scanner for<br />

LAMBDA 8XX/9XX<br />

Complete Gel-, Film-,<br />

and Filter-Scanner<br />

accessory for LAMBDA<br />

8XX/9XX. Allows<br />

measurement of 100 mm gel cuvettes or film and glass<br />

samples in continuous or random mode.<br />

Part No. Each (€)<br />

B2205420 3660<br />

Cell Holders<br />

To extend the range of samples you can analyze, we offer<br />

a wide range of sample cell holders.<br />

Standard Cell Holder<br />

The Standard Cell Holder<br />

is provided as standard<br />

equipment with your<br />

PerkinElmer LAMBDA Series<br />

instrument. A lifter (included)<br />

makes short cell removal<br />

easy. It accommodates a<br />

large selection of rectangular<br />

cells up to 10 mm pathlength. The Standard Cell Holder<br />

is adjustable both vertically and horizontally.<br />

Rectangular Long-Path<br />

Cell Holder for LAMBDA<br />

1X/2X/3X/4X/Bio<br />

The Rectangular Long-Path<br />

Cell Holder accepts cells with<br />

pathlengths from 10 to 100 mm.<br />

This optional cell holder is easy to<br />

install and has the same footprint<br />

as the Standard Cell Holder. It<br />

is designed for a precise fit and gives<br />

you maximum reproducibility.<br />

Part No. Each (€)<br />

Cylindrical Long-Path Cell Holder<br />

for LAMBDA 6XX/8XX/9XX<br />

Accommodates cylindrical cells with<br />

pathlengths up to 100 mm.<br />

Part No.<br />

Cylindrical Long-Path<br />

Cell Holder<br />

Each (€)<br />

B0505071 396<br />

B0080821 566<br />

The Cylindrical Long-Path<br />

Cell Holder accommodates<br />

cells with outside diameters<br />

from 22 to 30 mm. A versatile<br />

cell holder, it accepts cells<br />

with pathlengths up to<br />

100 mm. The spring loaded<br />

clamping arms provide a<br />

precise, reproducible fit and<br />

are easy to adjust.<br />

Part No.<br />

Each (€)<br />

C0550303 148<br />

Part No.<br />

Each (€)<br />

B0082539 264<br />

388


Cell Holders<br />

Solid Sample Holder<br />

Minimum sample size<br />

10 x 15 mm. Maximum<br />

sample thickness 5 mm.<br />

8-Cell Holder, Water Thermostattable<br />

Cells<br />

Cell Holders<br />

For Automatic Linear Transport for LAMBDA 1X/2X/3X/<br />

4X/Bio (B2000186) or LAMBDA 800/900 (B2205401) in<br />

sample or reference position.<br />

Accommodates up to eight<br />

10 mm cells.<br />

Part No.<br />

B2205411<br />

Each (€)<br />

544<br />

Part No. Each (€)<br />

B0080822 419<br />

Single-Cell Reference Holder<br />

For Automatic Linear Transport<br />

(B2000186). For one cell with up<br />

to 10 mm pathlength.<br />

Part No. Each (€)<br />

B2000201 359<br />

Long Pathlength 5-Cell Holder<br />

Test Tube Holder<br />

This holder accommodates<br />

test tubes from 11 to<br />

17 mm diameter.<br />

Variable Angle<br />

Sample Holder<br />

Part No.<br />

0° to 60° for sample position<br />

for measurement in transmission<br />

of filter glasses and other<br />

transparent samples. Minimum<br />

sample size is 30 x 40 mm.<br />

Part No.<br />

Each (€)<br />

B0500952 434<br />

Each (€)<br />

B0152471 1603<br />

For Automatic Linear Transport for LAMBDA 1X/2X/3X/<br />

4X/Bio (B2000186) or LAMBDA 800/900 (B2205401) in<br />

sample or reference position.<br />

Accommodates five cells<br />

of up to 50 mm pathlength.<br />

Part No.<br />

B0089439<br />

Each (€)<br />

472<br />

Glass/Quartz Cuvette Cell<br />

Holder/Carousel for 13-Cell Changer<br />

For use with the 13-Cell<br />

Changer (B1085210).<br />

Plastic Cuvette Cell Holder/Carousel<br />

for 13-Cell Changer<br />

For use with the 13-Cell<br />

Changer (B1085210).<br />

8-Cell Holder, Water Thermostattable for Manual<br />

Cell Changer for LAMBDA 1X/2X/3X/4X/Bio<br />

For Manual Cell Changer (B2500080).<br />

Accepts eight cells of up to<br />

10 mm pathlength.<br />

Long Pathlength Reference Cell Holder,<br />

Non-Thermostatted for LAMBDA 1X/2X/3X/4X/Bio<br />

For Manual Cell Changer (B2500080).<br />

Reference Cell Holder, Water Thermostattable<br />

for LAMBDA 1X/2X/3X/4X/Bio<br />

For Manual Cell Changer (B2500080).<br />

Part No.<br />

Part No.<br />

Each (€)<br />

B0193768 297<br />

Part No.<br />

Each (€)<br />

B2500081 664<br />

Part No.<br />

Each (€)<br />

B2500082 324<br />

Part No.<br />

Each (€)<br />

B0185163 323<br />

Each (€)<br />

B2500083 329<br />

Cells UV Visible<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

389


Cells<br />

Cells for Spectroscopy<br />

High Quality,<br />

Precision Cells<br />

Make Full Use of the Accuracy and<br />

Sensitivity of Your Optical Instrument<br />

No matter what type of cells your application requires –<br />

rectangular or cylindrical, standard or short path, micro,<br />

semi-micro, or flowcells – choosing only high quality,<br />

precision cells allows you to make full use of the<br />

accuracy and sensitivity of your optical instrument.<br />

PerkinElmer cells ensure top optical performance, with<br />

high cell transmission and accurate pathlength. The cell<br />

windows are fused to the bodies by a special process<br />

which avoids deformation of the windows. This assures<br />

that the full width of the cell is usable and the finished<br />

cell dimensions are maintained.<br />

PerkinElmer Spectroscopy Cells are available in a wide variety of sizes and types.<br />

Our cells are manufactured from various<br />

types of glass. We offer three basic<br />

materials, Special Optical Glass,<br />

SUPRASIL ® UV Quartz and SUPRASIL<br />

300 NIR Quartz in all the common sizes<br />

and types. The most important criterion<br />

for the choice of a particular type of glass<br />

is the spectral range for which the cell is<br />

intended. Color logos are fused onto each<br />

PerkinElmer cell, thus indicating the<br />

spectral range over which the cell can<br />

be used.<br />

Special Optical Glass<br />

Indicates that SCHOTT type UK 5 is<br />

used for cells referred to in the catalog<br />

as manufactured from “Special Optical<br />

Glass”. This crown glass is made from<br />

exceptionally pure raw materials, which<br />

gives an improved transmission in the<br />

near ultraviolet range. An empty cell<br />

will give a transmission of more than<br />

80% over a spectral range of between<br />

320 and 2500 nm.<br />

SUPRASIL UV Quartz<br />

Indicates that quartz of the highest<br />

purity and homogeneity has been used<br />

for the window. Because it is produced<br />

from a silicon compound, it is also<br />

called synthetic quartz. SUPRASIL<br />

gives transmission values of more than<br />

80% over a spectral range of between<br />

200 and 2500 nm for an empty cell.<br />

SUPRASIL 300 NIR Quartz<br />

Denotes a synthetic quartz that is free<br />

from OH absorption. Therefore it is<br />

suitable for applications in the near<br />

infrared range up to approximately<br />

4000 nm. SUPRASIL 300 gives a<br />

transmission of more than 80% over<br />

a spectral range of between 200 and<br />

3500 nm for an empty cell.<br />

390


Cells<br />

Cylindrical and Flow-Through Cells for Spectroscopy<br />

Cylindrical Cells – Macro with PTFE Stopper<br />

Cylindrical cells are used with spectrophotometers that have a larger, circular light beam. Each cell has an outside<br />

diameter of 22 mm and an inside diameter of 19 mm. Each package contains one cell and two windows.<br />

Lightpath Outside Cell<br />

Material mm Depth mm Volume Remarks Part No. Each (€)<br />

NIR Quartz 10 12.5 2.8 mL neck Ø 6 mm taper 1:10 B0631099 97<br />

SUPRASIL ® 300 20 22.5 5.6 mL neck NS 7 B0631100 97<br />

50 52.5 14.0 mL 2 necks NS 7 B0631101 129<br />

100 102.5 28.0 mL 2 necks NS 7 B0631102 143<br />

Quartz SUPRASIL 10 12.5 2.8 mL neck Ø 6 mm taper 1:10 B0631095 81<br />

20 22.5 5.6 mL neck NS 7 B0631096 85<br />

50 52.5 14.0 mL 2 necks NS 7 B0631097 113<br />

100 102.5 28.0 mL 2 necks NS 7 B0631098 127<br />

Special Optical Glass 10 12.5 2.8 mL neck Ø 6 mm taper 1:10 B0631091 53<br />

20 22.5 5.6 mL neck NS 7 B0631092 55<br />

50 52.5 14.0 mL 2 necks NS 7 B0631093 74<br />

100 102.5 28.0 mL 2 necks NS 7 B0631094 78<br />

Flow-through Cells<br />

NIR Quartz SUPRASIL Cylindrical<br />

Cells Macro with PTFE Stopper,<br />

10 mm Part No. B0631099<br />

Flow-through cells are used for measuring samples with continuous flow or with Sippers where individual samples are<br />

aspirated into the cell. All cells have center heights of 15 mm. Each package contains one cell with two clear windows. The<br />

cells listed below are Compact with two screw connectors, M6 x1 and 500 mm length FEP tubing - 1.9 mm o.d., 1.1 mm i.d.<br />

Lightpath Center Outside Dim. Aperture Cell<br />

Material mm Height mm H x W x D mm Volume Part No. Each (€)<br />

Quartz SUPRASIL 1 15 35 x 12.5 x 12.5 17.5 x 3.5 62 μL B0631085 506<br />

Quartz SUPRASIL 10 15 35 x 12.5 x 12.5 11 x 3.5 390 μL B0631084 268<br />

Quartz SUPRASIL 10 15 35 x 12.5 x 12.5 8 x 2 160 μL B0631087 297<br />

Quartz SUPRASIL 10 15 35 x 12.5 x 12.5 11 x 2.5 300 μL B0631150 583<br />

Quartz SUPRASIL 10 15 35 x 12.5 x 12.5 Ø 3 80 μL B0631089 278<br />

Quartz SUPRASIL 50 15 45 x 12.5 x 52.5 Ø 3 370 μL B0631088 659<br />

Quartz SUPRASIL 10 15 35 x 12.5 x 12.5 Ø 2 30 μL B0631090 274<br />

Quartz SUPRASIL (FIAS) 10 15 35 x 12.5 x 12.5 Ø 1.5 18 μL B0631151 529<br />

Quartz SUPRASIL (FIAS) 10 15 35 x 12.5 x 12.5 Ø 1 8 μL B0631152 308<br />

Lids and Stoppers<br />

Description Lightpath mm Part No. Each (€)<br />

Glass Covering Plate 1 B0631144 3<br />

PTFE Fitted Lid 5 B0631145 4<br />

PTFE Fitted Lid 10 B0631129 2<br />

PTFE Fitted Lid 20 B0631146 3<br />

PTFE Fitted Lid 50 B0631147 4<br />

Glass Fitted Lid 100 B0631148 15<br />

PTFE Stopper with NS 7 Fitting B0631128 3<br />

PTFE Stopper with Fitting Ø 6, taper 1:10 B0631149 3<br />

Replacement Tubing<br />

Description Part No. Each (€)<br />

FEP-Replacement Tubing with one short screw fitting, 500 mm long B0631130 25<br />

FEP-Replacement Tubing with one long screw fitting, 500 mm long B0631131 28<br />

Sipper Tubing to Cuvette (in) B2500129 75<br />

Sipper Tubing to Cuvette (out) B2500127 23<br />

FEP Tubing – Short Fitting<br />

Part No. B0631130<br />

FEP Tubing – Long Fitting<br />

Part No. B0631131<br />

Cells UV Visible<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

391


Cells<br />

Standard Cells for Spectroscopy<br />

Macro with PTFE Lid<br />

Standard rectangular Macro cells are the most common type of spectroscopy cell and are used for<br />

routine UV/VIS analysis. Each cell has a standard inside width of 9.5 mm and a base thickness<br />

of 1.5 mm. All Macro cells contain two clear windows.<br />

Lightpath Outside Dim. Cell<br />

Material mm H x W x D mm Volume Qty. Part No. Each (€)<br />

UV Visible Cells<br />

Special Optical Glass Macro<br />

with PTFE Lid, 10 mm<br />

Part No. B0631003<br />

NIR Quartz Macro<br />

with PTFE Stopper, 10 mm<br />

Part No. B0631033<br />

NIR Quartz SUPRASIL ® 300 1* 45 x 12.5 x 3.5 350 μL 2 B0631013 327<br />

5 45 x 12.5 x 7.5 1.75 mL 2 B0631014 177<br />

10 45 x 12.5 x 12.5 3.5 mL 2 B0631015 160<br />

20 45 x 12.5 x 22.5 7.0 mL 2 B0631016 332<br />

50 45 x 12.5 x 52.5 17.5 mL 1 B0631017 218<br />

100 45 x 12.5 x 102.5 35.0 mL 1 B0631018 200<br />

Optical Glass 10 45 x 12.5 x 12.5 3.5 mL 4 B0631134 120<br />

360-2500 nm without lid<br />

Quartz SUPRASIL 1* 45 x 12.5 x 3.5 350 μL 2 B0631007 150<br />

5 45 x 12.5 x 7.5 1.75 mL 2 B0631008 116<br />

10 45 x 12.5 x 12.5 3.5 mL 2 B0631009 111<br />

20 45 x 12.5 x 22.5 7.0 mL 2 B0631010 147<br />

50 45 x 12.5 x 52.5 17.5 mL 1 B0631011 118<br />

100 45 x 12.5 x 102.5 35.0 mL 1 B0631012 184<br />

Special Optical Glass 1* 45 x 12.5 x 3.5 350 μL 2 B0631001 84<br />

5 45 x 12.5 x 7.5 1.75 mL 2 B0631002 65<br />

10 45 x 12.5 x 12.5 3.5 mL 2 B0631003 54<br />

20 45 x 12.5 x 22.5 7.0 mL 2 B0631004 81<br />

50 45 x 12.5 x 52.5 17.5 mL 1 B0631005 62<br />

* Glass lid<br />

Macro with PTFE Stopper<br />

100 45 x 12.5 x 102.5 35.0 mL 1 B0631006 108<br />

Lightpath Outside Dim. Cell<br />

Material mm H x W x D mm Volume Qty. Part No. Each (€)<br />

NIR Quartz SUPRASIL 300 1 52 x 12.5 x 3.5 350 μL 2 B0631031 399<br />

5 46 x 12.5 x 7.5 1.75 mL 2 B0631032 356<br />

10 46 x 12.5 x 12.5 3.5 mL 2 B0631033 179<br />

20 46 x 12.5 x 22.5 7.0 mL 2 B0631034 200<br />

50 46 x 12.5 x 52.5 17.5 mL 1 B0631035 250<br />

100 46 x 12.5 x 102.5 35.0 mL 1 B0631036 467<br />

Quartz SUPRASIL 1 52 x 12.5 x 3.5 350 μL 2 B0631025 217<br />

5 46 x 12.5 x 7.5 1.75 mL 2 B0631026 159<br />

10 46 x 12.5 x 12.5 3.5 mL 2 B0631027 157<br />

20 46 x 12.5 x 22.5 7.0 mL 2 B0631028 351<br />

50 46 x 12.5 x 52.5 17.5 mL 1 B0631029 179<br />

100 46 x 12.5 x 102.5 35.0 mL 1 B0631030 327<br />

Special Optical Glass 1 48 x 12.5 x 3.5 350 μL 2 B0631019 170<br />

5 46 x 12.5 x 7.5 1.75 mL 2 B0631020 216<br />

10 46 x 12.5 x 12.5 3.5 mL 2 B0631021 100<br />

50 46 x 12.5 x 52.5 17.5 mL 1 B0631023 147<br />

392


Cells<br />

Standard Cells for Spectroscopy<br />

Micro with PTFE Lid<br />

Micro cells have the same outside dimension as the Macro cells but the cell walls have been thickened,<br />

limiting the interior sample chamber width to 2 mm. This reduces the sample requirements by 80%.<br />

Each Micro cell has a standard light path of 10 mm and each package contains two cells with two<br />

clear windows each. All Micro cells listed have black sidewalls and base.<br />

Outside Dim. Base Cell<br />

Material H x W x D mm Thickness mm Volume Part No. Each (€)<br />

Quartz SUPRASIL ® 45 x 12.5 x 12.5 3.2 700 μL B0631071 290<br />

Special Optical Glass 45 x 12.5 x 12.5 3.2 700 μL B0631070 97<br />

Quartz SUPRASIL Micro<br />

with PTFE Lid 10 mm<br />

Part No. B0631071<br />

Micro with PTFE Stopper<br />

Outside Dim. Base Cell<br />

Material H x W x D mm Thickness mm Volume Part No. Each (€)<br />

NIR Quartz SUPRASIL 300 40 x 12.5 x 12.5 1.5 400 μL B0631078 709<br />

Quartz SUPRASIL 40 x 12.5 x 12.5 1.5 400 μL B0631077 382<br />

Special Optical Glass 40 x 12.5 x 12.5 1.5 400 μL B0631076 190<br />

Semi-micro with PTFE Lid – Black<br />

Semi-micro cells have the same outside dimension as the Macro cells but the cell walls have been<br />

thickened slightly, limiting the interior sample chamber width to 4 mm. This reduces the sample<br />

requirements by 60%. Each cell has a base thickness of 3.2 mm and each package contains two cells<br />

with two clear windows each.<br />

Lightpath Outside Dim. Cell<br />

Material mm H x W x D mm Volume Part No. Each (€)<br />

NIR Quartz SUPRASIL 300 5 45 x 12.5 x 7.5 700 μL B0631050 451<br />

10 45 x 12.5 x 12.5 1.4 mL B0631051 451<br />

Quartz SUPRASIL 5 45 x 12.5 x 7.5 700 μL B0631048 329<br />

10 45 x 12.5 x 12.5 1.4 mL B0631049 331<br />

Special Optical Glass 5 45 x 12.5 x 7.5 700 μL B0631046 137<br />

Semi-micro with PTFE Lid – Clear<br />

10 45 x 12.5 x 12.5 1.4 mL B0631047 95<br />

Lightpath Outside Dim. Cell<br />

Material mm H x W x D mm Volume Part No. Each (€)<br />

NIR Quartz SUPRASIL 300 20 45 x 12.5 x 22.5 2.8 mL B0631045 422<br />

Quartz SUPRASIL 20 45 x 12.5 x 22.5 2.8 mL B0631042 182<br />

Special Optical Glass 20 45 x 12.5 x 22.5 2.8 mL B0631039 143<br />

Quartz SUPRASIL Micro<br />

with PTFE Stopper 10 mm<br />

Part No. B0631077<br />

Quartz SUPRASIL Semimicro<br />

with PTFE Lid 10 mm<br />

Part No. B0631049<br />

Cells UV Visible<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

393


Cells<br />

Standard Cells for Spectroscopy<br />

Semi-micro with PTFE Stopper – Black<br />

Lightpath Outside Dim. Cell<br />

Material mm H x W x D mm Volume Part No. Each (€)<br />

NIR Quartz SUPRASIL ® 300 5 46 x 12.5 x 7.5 700 μL B0631065 489<br />

10 46 x 12.5 x 12.5 1.4 mL B0631066 489<br />

Quartz SUPRASIL 10 46 x 12.5 x 12.5 1.4 mL B0631064 580<br />

Special Optical Glass 5 46 x 12.5 x 7.5 700 μL B0631061 214<br />

Quartz SUPRASIL<br />

Semi-micro with PTFE<br />

Stopper 10 mm<br />

Part No. B0631064<br />

Semi-micro with PTFE Stopper – Clear<br />

Lightpath Outside Dim. Cell<br />

Material mm H x W x D mm Volume Part No. Each (€)<br />

UV Visible Cells<br />

Quartz SUPRASIL<br />

Ultra-micro with Pipette<br />

Tips 0.1 mm<br />

Part No. B0631082<br />

NIR Quartz SUPRASIL 300 20 46 x 12.5 x 22.5 2.8 mL B0631060 385<br />

Quartz SUPRASIL 20 46 x 12.5 x 22.5 2.8 mL B0631057 474<br />

Ultra-micro with PTFE Lid<br />

Ultra-micro cells use a narrower sample chamber, raising it directly into the center of the light path<br />

and masking it with black quartz. This design optimizes the use of smaller sample volumes. All<br />

Ultra-micro cells contain one cell and two clear windows.<br />

Lightpath Center Outside Dim. Aperture Chamber Filling<br />

Material mm Height mm H x W x D mm mm Vol. Vol. Part No. Each (€)<br />

Quartz SUPRASIL 10 15 45 x 12.5 x 12.5 2 x 1.5 30 μL 50 μL B0631079 206<br />

Ultra-micro with Pipette Tips<br />

Ultra-micro cells with Pipette Tips are available in Quartz SUPRASIL with center heights of 15 mm.<br />

Each package contains one cell with two clear windows.<br />

Lightpath Outside Dim. Aperture Chamber Filling<br />

Material mm H x W x D mm mm Vol. Vol. Part No. Each (€)<br />

Quartz SUPRASIL 0.1 40 x 12.5 x 12.5 1 x 5 0.5 μL 2 μL B0631082 420<br />

1 40 x 12.5 x 12.5 1 x 5 5 μL 10 μL B0631083 394<br />

5 45 x 12.5 x 12.5 Ø 0.8 2.5 μL 5 μL B0631080 385<br />

10 40 x 12.5 x 12.5 Ø 0.8 5 μL 10 μL B0631081 361<br />

394


Consumables and Supplies<br />

Calibration Reference Materials<br />

Secondary Reference Materials<br />

PerkinElmer reference materials speed calibration verification<br />

of UV/Vis and UV/Vis/NIR Spectrophotometers,* providing<br />

laboratory managers with the evidence they need to pass<br />

the strictest quality audit.<br />

A comprehensive range of certified traceable filters and<br />

sealed cuvettes fit into the standard instrument cuvette<br />

holder allowing users to generate simple protocols to verify<br />

ordinate and abscissa accuracy, stray light radiation, and<br />

spectral resolution. There is also a range of color and<br />

reflectance materials specifically designed for the popular<br />

LAMBDA 9/18/19/8XX/9XX Spectrophotometers.<br />

All reference materials are certified traceable to NIST<br />

primary reference material and supplied with a calibration<br />

certificate detailing the calibration method and results.<br />

A USA-based calibration laboratory ensures a reliable<br />

two-week turnaround service for periodical recalibrations,<br />

allowing laboratories to maintain the requirements of their<br />

calibration SOPs.<br />

Key features:<br />

Comprehensive range of materials<br />

Traceable to NIST<br />

Immediate availability<br />

Rapid recalibration service<br />

* Not diode array spectrometers<br />

Photometric and Wavelength Accuracy<br />

Reference Material Set<br />

Set of reference materials to verify the ordinate and<br />

abscissa (wavelength) accuracy of UV/Vis and UV/Vis/NIR<br />

Spectrophotometers. The set comprises four glass filters<br />

mounted in precision aluminum spring mounts. They are<br />

designed for use with the standard 10 mm cuvette holders<br />

of most UV/Vis and UV/Vis/NIR Spectrophotometers. The<br />

set is provided in a robust aluminum container. There are<br />

three neutral density glass filters for checking the ordinate<br />

accuracy and a holmium oxide glass filter for checking the<br />

wavelength accuracy of a spectrometer. Each filter has<br />

an identification number. The ordinate and abscissa values<br />

of each filter are quoted in the accompanying Certificate<br />

of Calibration. NG nominal 10%,<br />

20%, 50%/holmium oxide filter.<br />

Part No. Each (€)<br />

B0507805 1671<br />

Stray Light Solutions Reference Material Set<br />

Set comprising four solutions in sealed cells – one reference<br />

solution and three test solutions. The cells are designed for<br />

use with the standard 10 mm cuvette holders of most<br />

UV/Vis and UV/Vis/NIR Spectrophotometers. The test<br />

solutions comprising sodium iodide, sodium nitrite, and<br />

potassium chloride, act as a cut-off filter with a very precise<br />

wavelength. The set is provided in a robust aluminum<br />

container with a Certificate of<br />

Calibration. Sodium iodide, sodium Part No. Each (€)<br />

nitrite, potassium chloride, and water. B2500099 2166<br />

Pharmacopoeia Solutions Reference Material Set<br />

Set of sealed cells to verify calibration in accordance with<br />

Pharmacopoeia monographs.<br />

Ordinate (photometric) accuracy; potassium dichromate<br />

Abscissa (wavelength) accuracy; holmium perchlorate<br />

Level of stray radiation; potassium chloride<br />

Resolution; toluene in hexane<br />

Set comprising six solutions in sealed cells – two reference<br />

solutions and four test solutions. The cells are designed for<br />

use with the standard 10 mm cuvette holders of most UV/Vis<br />

and UV/Vis/NIR Spectrophotometers. The set is provided<br />

in two robust aluminum containers with a Certificate of<br />

Calibration. Potassium dichromate/potassium chloride,<br />

holmium perchlorate, and toluene.<br />

Part No. Each (€)<br />

Photometric and Wavelength Accuracy<br />

Reference Material Set Part No. B0507805<br />

B2500100 3903<br />

Consumables and Supplies UV Visible<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

395


Consumables and Supplies<br />

Calibration Reference Materials<br />

UV Visible Consumables and Supplies<br />

Spectralon ® UV/Vis/NIR Diffuse<br />

Reflectance Reference Material<br />

For use with LAMBDA 9/18/19/8XX/9XX<br />

150 mm integrating spheres<br />

Durable, chemically inert<br />

High reflectance values – 95 to 99%<br />

Washable<br />

Direct traceability to the National Institute<br />

of Standards and Technology (NIST)<br />

Spectralon diffuse reflectance standard sets consist of a<br />

diffuse white standard and a selection of diffuse gray<br />

reference material. Each standard in the set is supplied<br />

with complete diffuse reflectance data from 250 to 2500 nm,<br />

and is mounted in an anodized aluminum frame. The set is<br />

packed in an airtight storage case.<br />

Calibrated Diffuse Reflectance Reference<br />

Materials, Set of Four (1.25")<br />

Reflectance factors:<br />

99%, 75%, 50%, and 2%.<br />

Calibrated Diffuse Reflectance Reference<br />

Materials, Set of Eight (1.25")<br />

Reflectance factors: 99%, 80%,<br />

60%, 40%, 20%, 10%, 5%, and 2%.<br />

Calibrated Diffuse Reflectance Reference<br />

Materials, Set of Eight (2")<br />

Reflectance factors: 99%, 80%,<br />

60%, 40%, 20%, 10%, 5%, and 2%.<br />

Spectralon Diffuse<br />

Color Reference Material<br />

For use with LAMBDA 9/18/19/8XX/9XX<br />

150 mm integrating spheres<br />

Durable, chemically inert<br />

Highly diffuse<br />

Consistent reflectance<br />

Non-thermochromic<br />

Part No.<br />

Each (€)<br />

PELA9010 1242<br />

Part No.<br />

Each (€)<br />

PELA9012 3696<br />

Part No.<br />

Each (€)<br />

PELA9013 2739<br />

These durable, waterproof reference materials can be washed<br />

and easily machined without loss of color or surface texture.<br />

They are non-thermochromic, so there is no need to control<br />

laboratory temperature. As in the Diffuse Reflectance Reference<br />

Material Set, reference materials are supplied with data from<br />

250 to 2500 nm, mounted in anodized aluminum frames,<br />

and packed in an airtight case.<br />

Calibrated Diffuse Color Reference<br />

Materials, Set of Four (2")<br />

Set includes one each: red, green,<br />

blue, and yellow standard.<br />

Calibrated Diffuse Color and Neutral Reference<br />

Materials, Set of Eight (2")<br />

Set includes one each: red, green, blue, yellow, and four<br />

diffuse reflectance reference<br />

materials: 99%, 75%, 50%, and 2%. Part No. Each (€)<br />

Calibrated Diffuse Color Reference<br />

Materials,Set of Eight (2")<br />

Set includes one each: red, green, blue,<br />

yellow, orange, purple, cyan, and violet.<br />

Miscellaneous Calibration Materials<br />

Disposable Reference Mirror for<br />

Reflectance Spectroscopy<br />

This mirror is necessary to check the accuracy of absolute<br />

and to correct the spectra of non-absolute specular reflectance<br />

accessories. The mirror is a secondary standard and is<br />

calibrated according to GLP regulations,<br />

wavelength range 250 to 2500 nm. Part No. Each (€)<br />

Recalibration Reference Material<br />

To guarantee the integrity of the reference materials, you<br />

should have them recalibrated at periodic intervals. The<br />

recommended recalibration frequency is shown on the<br />

enclosed Certificate of Calibration. PerkinElmer will<br />

perform recalibration.<br />

Quantity Part No. Each (€)<br />

Set N1010539 938<br />

Single N1010540 263<br />

Spectralon Calibrated White Plate<br />

Size Part No. Each (€)<br />

1.25" PELA9057 688<br />

2.00" PELA9058 813<br />

Spectralon Calibrated Diffuse Reflectance<br />

Reference Material Set, Color<br />

Calibrated Spectralon color<br />

reference materials, set of four,<br />

and approximately 5 cm diameter.<br />

Part No.<br />

Each (€)<br />

PELA9018 1854<br />

PELA9020 4928<br />

Part No.<br />

Each (€)<br />

PELA9021 2767<br />

N1010504 1232<br />

Part No.<br />

Each (€)<br />

PELA9019 1854<br />

396


Consumables and Supplies<br />

Source Lamps<br />

Deuterium and Tungsten<br />

Source Lamps<br />

For optimum instrument performance, always use original<br />

replacement sources from PerkinElmer.<br />

Our extensive quality control and inspection process<br />

demands the very best quality sources. This guarantees<br />

top performance and maximum stability from your<br />

UV/Vis Spectrophotometer.<br />

Installation of a new lamp by a PerkinElmer Service Engineer<br />

is recommended for proper lamp alignment. Optimum<br />

performance is achieved when the lamp is correctly aligned.<br />

Eye protection is required when viewing deuterium or<br />

tungsten lamps when lit.<br />

Deuterium Lamp<br />

Part No. B0160917<br />

Tungsten Lamp<br />

Part No. B0114620<br />

Deuterium Lamps for LAMBDA Spectrophotometers<br />

LAMBDA Model Part No. Each (€)<br />

For LAMBDA 1/3 C0550505 610<br />

For LAMBDA 1X/2X/3X/4X/5X/5XX/Bio/6XX/8XX/9XX B0160917 579<br />

For LAMBDA 4/6 C6880055 676<br />

Tungsten Lamps for LAMBDA Spectrophotometers<br />

LAMBDA Model Part No. Each (€)<br />

For LAMBDA 1/3* C0550500 69<br />

For LAMBDA 1X/2X/3X/4X/Bio/6XX/8XX/9XX B0114620 98<br />

For LAMBDA 4/6* C6880054 97<br />

For 5X/5XX B0091906 120<br />

* Prefocused and prealigned<br />

Consumables and Supplies UV Visible<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

397


Software<br />

UV/Vis Application and Operating System Software<br />

UV Visible Software<br />

Advanced Applications Software<br />

PerkinElmer offers a variety of Advanced Application Software<br />

packages for use with your UV/Vis system. All programs:<br />

Include Results Database software (L6100050)<br />

Are validated under Windows 2000 and XP<br />

Require UV Winlab 2.85 or later for operation with<br />

the LAMBDA 25, 35, and 45<br />

Require UV Winlab 3.0 or later for operation with<br />

the LAMBDA 6XX/8XX/9XX<br />

Architectural Glass Software<br />

Software to enable the reflectance and transmittance<br />

properties of thin-film coatings applied to architectural glass<br />

to be evaluated. Included are ISO, DIN, and ASTM methods<br />

for light, solar, and UV, UVA, and UVB and normal, double,<br />

and triple glazing.<br />

LAMBDA Model WinLab Version Part No. Each (€)<br />

25/35/45/6XX/8XX/9XX 3.0 or earlier L6100047 938<br />

6XX/8XX/9XX 5.0 L6100116 938<br />

Color Methods Software<br />

A software package to calculate color indices for liquids,<br />

and clear and opaque solids. Compliant with all the major<br />

CIE, ASTM, DIN, and ISO methodologies, the software<br />

includes predefined illuminants, observers, and calculations<br />

required by the above along with easy-to-use graphical<br />

representation of results.<br />

LAMBDA Model WinLab Version Part No. Each (€)<br />

25/35/45/6XX/8XX/9XX 3.0 or earlier L6100046 1564<br />

6XX/8XX/9XX 5.0 L6100114 1564<br />

Filter Testing Software<br />

A dedicated software package to evaluate transmission<br />

characteristics of optical thin-film coatings for bandpass<br />

and non-bandpass filters.<br />

LAMBDA Model WinLab Version Part No. Each (€)<br />

25/35/45/6XX/8XX/9XX 3.0 or earlier L6100049 688<br />

6XX/8XX/9XX 5.0 L6100115 688<br />

Protection Glass Software<br />

Software offering industry standard calculations required<br />

for personal and industrial eye protection. Included are<br />

luminous, visible, UV, and near-IR transmittance calculations<br />

along with shade number and relative visual attenuation.<br />

LAMBDA Model WinLab Version Part No. Each (€)<br />

25/35/45/6XX/8XX/9XX 3.0 or earlier L6100048 938<br />

6XX/8XX/9XX 5.0 L6100117 938<br />

UV WinLab<br />

UV WinLab v5 Upgrade<br />

UV WinLab v5 is designed to simplify and speed the<br />

analysis performed on the LAMBDA family of instruments<br />

by mimicking the QA workflow. The ability to pre-define<br />

and lock methods ensures that the analyst is presented with<br />

only the information needed to perform the analysis.<br />

Using the latest database technology data retrieval is quick<br />

and easy. A range of intelligent querying and charting<br />

options transforms data from a collection of individual<br />

results into a store of valuable knowledge that aids faster<br />

decision-making.<br />

The Communiqué TM reporting environment provides<br />

customized report templates, including company logos,<br />

results, sample descriptions and spectra, using a simple<br />

drag and drop editor. GLP information, including method<br />

revision, analyst’s name and time and date of the analysis<br />

is automatically included, and reports can even be<br />

automatically e-mailed at the end of an analysis.<br />

The ES (Enhanced Security) version of UV WinLab v5<br />

software integrates technical compliance with the FDA<br />

regulation 21 CFR Part 11, within the workflow user<br />

interface. Unlike other packages with “bolt-on” compliance<br />

modules, UV WinLab ES eliminates compliance loopholes,<br />

without compromising productivity. E-signatures can be<br />

placed where you need them in the workflow.<br />

UV WinLab v5 Upgrade can be used to upgrade the<br />

LAMBDA 20, 25, 35, 40, 45, 6XX, 8XX, and 9XX. Earlier<br />

instruments are not supported. UV WinLab v5 does NOT<br />

support the following accessories:<br />

Research Peltiers (PTP-1 and PTP-6)<br />

Vacuum Pinch Sipper<br />

Vacuum Solenoid Sipper<br />

Gel-Scanner Linear Transport for Gels and Glasses<br />

The Research Peltiers can be used with UV WinLab ES v5<br />

but any setting of the temperature of ramping must be<br />

performed via the local interface on the accessory.<br />

Upgrade Information Part No. Each (€)<br />

From UV WinLab v3 or Lower to UV WinLab v5 L6100095 1564<br />

From UV WinLab v3 or Lower to UV WinLab ES v5 L6100096 3753<br />

From UV WinLab v4 to UV WinLab v5 L6100097 375<br />

From UV WinLab v4 to UV WinLab ES v5 L6100099 1251<br />

From UV WinLab v4 ES to UV WinLab ES v5 L6100098 375<br />

UV WinLab v5 Multi-User License<br />

Description Part No. Each (€)<br />

UV WinLab v5 5-User License L6100102 5600<br />

UV WinLab ES v5 5-User License L6100103 9000<br />

UV WinLab v5 10-User License L6100104 9700<br />

UV WinLab ES v5 10-User License L6100105 15500<br />

UV WinLab 2.8 Upgrade for<br />

LAMBDA 1X/2X/3X/4X/Bio<br />

Part No.<br />

Each (€)<br />

L6100013 1327<br />

398


Polarimetry Supplies<br />

Polarimetry Consumables<br />

Polarimetry Cells<br />

Our polarimetry cells are exclusively manufactured for<br />

PerkinElmer. Use them to maintain the high level of accuracy<br />

and precision of your PerkinElmer Polarimeter. They are<br />

manufactured by a special process in which the windows<br />

are fused to the cell bodies to ensure that they are free<br />

of tension. Because the windows are not mechanically<br />

inserted, birefringence effects, which could affect the<br />

accuracy of your reading, are eliminated.<br />

Each of our polarimetry cells is individually tested with<br />

respect to its pathlength. The actual pathlength of each cell<br />

is engraved on the cell to the nearest 0.001 cm (i.e. to the<br />

nearest 0.01 mm), together with the serial number of the cell.<br />

All cells are jacketed for thermostatting with constant<br />

temperature water, except for one flowcell. Their residual<br />

cell rotation is almost zero and may be neglected in<br />

most measurements.<br />

Cells are designed for easy filling and emptying, with no<br />

loss of sample. The filling ports are arranged so that liquid<br />

flows over the inner window surfaces. A wide variety of<br />

cells made of fused silica are available. These cells are used<br />

for measurements of optical rotation in the ultraviolet range<br />

or at elevated temperatures.<br />

PerkinElmer offers a wide range of polarimetry sample<br />

cells for virtually all applications, including micro cells,<br />

short path cells, flow cells, and fused silica (quartz) cells.<br />

Use quartz cells for all wavelengths and for elevated<br />

temperatures (200 °C, maximum). Use glass cells only<br />

for visible wavelengths, above 400 nm.<br />

Standard Cells for Polarimetry<br />

Material Lightpath Cell Vol. Part No. Each (€)<br />

Quartz, Fused Silica 100 mm 6.2 mL B0041696 1006<br />

Quartz, Fused Silica* 100 mm 3.0 mL B0507403 1297<br />

Optical Glass 100 mm 6.2 mL B0041693 677<br />

Optical Glass* 100 mm 3.0 mL B0507447 643<br />

* Reduced volume<br />

Short Path Cells for Polarimetry<br />

Material Lightpath Cell Vol. Part No. Each (€)<br />

Quartz, Fused Silica 20 mm 1.3 mL B0022087 1836<br />

Quartz, Fused Silica 10 mm 0.6 mL B0022088 1440<br />

Optical Glass 10 mm 0.5 mL B0017052 896<br />

Optical Glass 1 mm 0.25 mL B0017057 896<br />

Micro Cells for Polarimetry<br />

Material Lightpath Cell Vol. Part No. Each (€)<br />

Quartz, Fused Silica 100 mm 1.0 mL B0023365 1396<br />

Quartz, Fused Silica* 100 mm 0.35 mL B0131186 1781<br />

Optical Glass 100 mm 1.0 mL B0017047 690<br />

* With reduced inner diameter<br />

Beaker Cells for Polarimetry<br />

Beaker cells are not thermostattable.<br />

Material Lightpath Cell Vol. Part No. Each (€)<br />

Quartz, Fused Silica 100 mm 50 mL B0023363 1396<br />

Optical Glass 100 mm 50 mL B0017041 451<br />

Flow Cells for Polarimetry<br />

Material Lightpath Cell Vol. Part No. Each (€)<br />

Quartz, Fused Silica* 100 mm 6.2 mL B0507451 1539<br />

Optical Glass 100 mm 5.0 mL B0017054 951<br />

* With two PTFE tubing (4 mm i.d.)<br />

LC Cells for Polarimetry<br />

LC cells have PTFE connecting capillaries, and<br />

are not thermostattable.<br />

Material Lightpath Cell Vol. Part No. Each (€)<br />

Quartz, Fused Silica 100 mm 80 μL B0107592 2028<br />

Quartz, Fused Silica 100 mm 40 μL B0107593 2265<br />

LC Alignment Cell<br />

For aligning the special LC cell holder.<br />

Part No.<br />

Each(€)<br />

B0017072 753<br />

Polarimetry Supplies UV Visible<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

399


Polarimetry Supplies<br />

Polarimetry Consumables and Software<br />

UV Visible Polarimetry Supplies<br />

Interference Filters, Replacement<br />

Parts and Source Lamps<br />

Optional Interference Filter<br />

For Model 341 Polarimeters.<br />

Service installation recommended.<br />

Wavelength Part No. Each (€)<br />

302 nm B0094404 706<br />

325 nm B2100154 933<br />

405 nm B0062666 649<br />

Pluggable Coupling<br />

For cell thermostatting.<br />

Connection Part No. Each (€)<br />

Female B0023491 54<br />

Male B0023492 43<br />

PTFE Stopper<br />

10 mm long.<br />

Cell Compatibility Diameter Part No. Each (€)<br />

017 047/017 057/022 086 - 3 mm B0017059 4<br />

022 091/023 365/037 634/<br />

037 635/022 085/037 357<br />

041 693/041 696 6 mm B0041695 4<br />

Polyethylene Protective End Caps<br />

For polarimetry cells and quartz<br />

control plates. (pkg. 20)<br />

Source Lamps<br />

Part No.<br />

Each (€)<br />

B0076786 21<br />

High-quality source lamps, specifically selected to optimize<br />

the performance of all PerkinElmer Polarimeters, offer high<br />

radiant energy and a long operating lifetime. As a result,<br />

precise measurements of optical rotation can be made,<br />

even when the sample absorbs strongly.<br />

Description Polarimeter Model Part No. Each (€)<br />

Sodium, 20 W 341/343/343plus/341LC/ B0008754 345<br />

241/241MC/243/243B<br />

Mercury Vapor (St46) 341/343S/343plus/341LC B0510581 585<br />

Polarimetry Software<br />

Pol WinLab Software CD Upgrade Kit<br />

A software upgrade for PerkinElmer polarimeters. Pol<br />

WinLab software allows complete instrument control with<br />

data acquisition and storage. Both Wavelength Program and<br />

Time drive methods are equipped with a report generator<br />

and result calculator. The software package also includes<br />

instrument validation and pre-programmed methods for<br />

most common applications.<br />

Does not support 14X and 24X Series polarimeters.<br />

Requires, but does not include, PC<br />

and RS-232C Cable (B0180242).<br />

Part No.<br />

Pol WinLab ES Software CD Kit<br />

An optional 21 CFR Part II compliant software package for<br />

PerkinElmer polarimeters. Pol WinLab ES software allows<br />

complete instrument control with data acquisition and<br />

storage. Both Wavelength Program and Time drive methods<br />

are equipped with a report generator and result calculator.<br />

The software package also includes instrument validation<br />

and pre-programmed methods for most common<br />

applications. The Software package offers full security<br />

features including electronic signature, password protected<br />

login, user rights, and audit trail.<br />

Does not support 14X and 24X Series polarimeters.<br />

Requires, but does not include, PC<br />

and RS-232C Cable (B0180242).<br />

Part No.<br />

Secondary Standards<br />

Secondary quartz standards are available for instrument<br />

validation. Quartz control plates can be calibrated for<br />

wavelengths in the visible spectral range only.<br />

Quartz Control Plate +1° at 589 nm<br />

With thermostattable housing,<br />

nominal rotation +1° at 589 nm<br />

(NaD). Secondary standard.<br />

Quartz Control Plate -1° at 589 nm<br />

With thermostattable housing,<br />

nominal rotation -1° at 589 nm<br />

(NaD). Secondary standard.<br />

Each (€)<br />

L6100081 1611<br />

Each (€)<br />

L6100082 4510<br />

Part No.<br />

Each (€)<br />

B0098800 3014<br />

Part No.<br />

Each (€)<br />

B0098799 3014<br />

400


Robust and comprehensive, efficient and uncomplicated<br />

ADVANCED Guide to Online Ordering<br />

www.perkinelmer.com/<strong>supplies</strong><br />

The PerkinElmer online ordering process is designed to help you find exactly what you need quickly and easily, and then<br />

receive it in a timely manner. Whether you choose QUICK Registration for streamlined service, or FULL Registration to gain<br />

all the advantages of the PerkinElmer ordering system, your shopping experience will be efficient and convenient.<br />

FULL Registration...<br />

Using FULL Registration increases<br />

the benefits of ordering online from<br />

PerkinElmer. You can:<br />

Enjoy a convenient process.<br />

Simply enter your account number,<br />

then confirm and select a billing address<br />

on the next page. If you don't have<br />

your account number available when<br />

ordering, submit your ship-to and/or<br />

bill-to addresses. After placing your<br />

order, you should receive an email<br />

notifying you that the order has been<br />

linked to your account.<br />

Receive special offers.<br />

You’ll have the opportunity to sign up<br />

for optional newsletters and periodic<br />

promotions so you can learn about and<br />

save on products you use every day.<br />

ADVANCED Guide to Online Ordering<br />

... vs. QUICK Registration<br />

If you want to place an order but<br />

don’t wish to receive the benefits<br />

of FULL Registration right now,<br />

then QUICK Registration is for you.<br />

With QUICK Registration, you can:<br />

Order with minimal information<br />

Shop by product number<br />

Get price and availability in the<br />

Shopping Cart<br />

PerkinElmer Consumables and Accessories<br />

For a complete listing of all local offices and mailing addresses go to pages 2-4 or visit<br />

www.perkinelmer.com/lasoffices or e-mail us: las.<strong>supplies</strong>@perkinelmer.com<br />

401


ADVANCED Guide to Online Ordering<br />

ADVANCED Guide to Online Ordering<br />

www.perkinelmer.com/<strong>supplies</strong><br />

Now that you’ve registered and are ready to order online, you’ll find many valuable tools that can simplify your experience.<br />

For example, you can recreate past orders to easily reorder what worked best for you, or even create a “Favorites” list to<br />

keep those product numbers handy. These features and others, described in detail below, can maximize your time online<br />

and help ensure your laboratory is fully stocked and running smoothly.<br />

When ordering from www.perkinelmer.com/<strong>supplies</strong> you can:<br />

Shop by product number • Quickly reorder from a favorites list or past order • Schedule recurring orders<br />

Estimate delivery time • Check order status • Track shipping<br />

Shop by<br />

Product Number<br />

Simply enter the desired product<br />

number found on our website,<br />

or the part number in this<br />

catalog. For your convenience,<br />

you can add up to 20 products<br />

to your Shopping Cart at one time.<br />

PerkinElmer Consumables and Accessories<br />

Create a Favorites List<br />

Another way to expedite orders is to create a “Favorites” list. Simply add<br />

products from any product page, past order or your Shopping Cart… 20 products<br />

can be stored at one time. Then, to order one or more of these items, simply click<br />

on “Favorites” from the Home Page or the My Account page to make your selection.<br />

402<br />

www.perkinelmer.com/<strong>supplies</strong>


ADVANCED Guide to Online Ordering<br />

www.perkinelmer.com/<strong>supplies</strong><br />

Recreate Past<br />

Orders Quickly<br />

This is a great time-saving feature if<br />

you typically order the same things<br />

frequently and have multiple line<br />

items per order. You can look up any<br />

past order – whether it was placed<br />

by phone, fax or online. From the<br />

Order Details page, you can choose<br />

some or all of the line items to add<br />

to a new Shopping Cart.<br />

ADVANCED Guide to Online Ordering<br />

Schedule Recurring Orders<br />

Do you have certain <strong>supplies</strong>, like<br />

Graphite Furnace Tubes, that constantly<br />

need replenishing? A Recurring Order<br />

ensures you’ll never run out by having<br />

a specified quantity automatically shipped<br />

on a regular basis. Save the time of<br />

re-ordering – you’ll get added savings, too.<br />

This valuable option allows you to<br />

schedule orders up to two years in advance,<br />

as if you were scheduling a recurring<br />

meeting on your calendar. You choose the<br />

order frequency: weekly, once every two<br />

weeks, monthly or once every two months.<br />

You can easily edit that schedule on the<br />

shipping confirmation page.<br />

For short-duration orders, you can design<br />

a customized shipping schedule for each<br />

line item, specifying exactly when you<br />

want the shipment to leave PerkinElmer –<br />

on the day it is available or a specific date<br />

in the future.<br />

PerkinElmer Consumables and Accessories<br />

For a complete listing of all local offices and mailing addresses go to pages 2-4 or visit<br />

www.perkinelmer.com/lasoffices or e-mail us: las.<strong>supplies</strong>@perkinelmer.com<br />

403


ADVANCED Guide to Online Ordering<br />

PerkinElmer Consumables and Accessories ADVANCED Guide to Online Ordering<br />

www.perkinelmer.com/<strong>supplies</strong><br />

Check Product Availability<br />

Your Shopping Cart contains important information, including<br />

a “Delivery Time Estimation” for each product you order. The<br />

“Date Available” shows when the product will be available for<br />

shipping and, for your convenience, exceptions to<br />

the normal shipping time will be indicated. On<br />

this page you also have the ability to select future<br />

shipment dates that better fit your needs.<br />

Here, you can also determine the status of<br />

your order and view its progress using our<br />

tracking capabilities – whether that order<br />

was placed by phone, fax or online.<br />

Customize your<br />

Shipping Information<br />

To ensure your materials reach their destination<br />

safely, you can customize your shipping information<br />

in several ways –<br />

“Attention/Recipient” is the name that will appear on<br />

the shipping label and packing list to correctly route the<br />

shipment when it arrives at your company.<br />

“Special Shipping Instructions” enable you to designate<br />

a shipping carrier and account number, or request special<br />

packaging for hazardous materials. These will be reviewed by<br />

PerkinElmer Customer Care and appear on the packing list.<br />

“Internal Delivery Instructions” are more specific<br />

directions you can include. They will appear on the<br />

packing list to help your receiving department. They<br />

could include information such as building and lab number,<br />

receiving hours or special handling instructions.<br />

“Customer Specific Instructions” allow you to take even<br />

greater control of your account by establishing permanent<br />

messages that will pop up each time an order is entered.<br />

You can identify details such as valid internal Purchase<br />

Order formats and authorized purchasers.<br />

404 www.perkinelmer.com/<strong>supplies</strong>


ADVANCED Guide to Online Ordering<br />

www.perkinelmer.com/<strong>supplies</strong><br />

ADVANCED Guide to Online Ordering<br />

Online Help (and how to get it)<br />

Our goal is to streamline your shopping experience. We are available to assist in many ways:<br />

“Ask Customer Care” link: Located on each page of registration and checkout, the symbol will lead you<br />

to page-specific help as well as the contact information for Customer Care.<br />

Help windows: If you see a term or phrase with a dashed underline, simply click on it for clarification.<br />

“How to Order Online” link: Look for this window in the “My Account” section found at www.perkinelmer.com/las.<br />

You’ll get a comprehensive overview to ordering online with PerkinElmer.<br />

Questions? Our knowledgeable Customer<br />

Care Representatives are ready to help.<br />

Simply contact your local PerkinElmer office<br />

(see pages 2-4 for local office listings).<br />

PerkinElmer Consumables and Accessories<br />

For a complete listing of all local offices and mailing addresses go to pages 2-4 or visit<br />

www.perkinelmer.com/lasoffices or e-mail us: las.<strong>supplies</strong>@perkinelmer.com<br />

405


Indexes<br />

Indexes


00071006 – 03190035 Part Number Index<br />

Index<br />

Part Number<br />

407<br />

00071006 . . . . . . . . . . . . . . . . . . . . . . . . . . . 56<br />

00080100 . . . . . . 131-132, 135, 139, 141, 153<br />

00090652 . . . . . . . . . . . . . . . . . . . . . . . . . . 159<br />

00090699 . . . . . . . . . . . . . . . . . . . . . . . 90, 272<br />

00090709 . . . . . . . . . . . . . . . . . . . . . . . . . . . 80<br />

00091279 . . . . . . . . . . . . . . . . . . . . . . . . . . 134<br />

00091357 . . . . . . . . . . . . . . . . . . . . . . . . . . 159<br />

00091667 . . . . . . . . . . . . . . . . . . . . . . . . . . 131<br />

00230090 . . . . . . . . . . . . . . . . . . . . . . 165, 318<br />

00230091 . . . . . . . . . . . . . . . . . . . . . . . . . . 165<br />

00230111 . . . . . . . . . . . . . . . . . . . . . . . . . . 162<br />

00230113 . . . . . . . . . . . . . . . . . . . . . . . . . . 161<br />

00230177 . . . . . . . . . . . . . . . . . . . . . . . . . . 162<br />

00230178 . . . . . . . . . . . . . . . . . . . . . . . . . . 162<br />

00230253 . . . . . . . . . . . . . . . . . . . . . . . . . . 165<br />

00230522 . . . . . . . . . . . . . . . . . . . . . . . . . . 167<br />

00230523 . . . . . . . . . . . . . . . . . . . . . . . . . . 161<br />

00400266 . . . . . . . . . . . . . . . . . . . . . . . . . . . 14<br />

00400275 . . . . . . . . . . . . . . . . . . . . . . . . . . . 14<br />

00400276 . . . . . . . . . . . . . . . . . . . . . . . . . . . 14<br />

00400277 . . . . . . . . . . . . . . . . . . . . . . . . . . . 14<br />

00400289 . . . . . . . . . . . . . . . . . . . . . . . . . . . 14<br />

00402237 . . . . . . . . . . . . . . . . . . . . . . 291-292<br />

00402239 . . . . . . . . . . . . . . . . . . . . . . . . . . 291<br />

00402240 . . . . . . . . . . . . . . . . . . . . . . . . . . 291<br />

00402241 . . . . . . . . . . . . . . . . . . . . . . . . . . 291<br />

00402243 . . . . . . . . . . . . . . . . . . . . . . . . . . 291<br />

00403058 . . . . . . . . . . . . . . . . . . . . . . . . . . 291<br />

00470258 . . . . . . . . . . . . . . . . . . . . . . . . . . . 37<br />

00470391 . . . . . . . . . . . . . . . . . . . . . . . . . . . 14<br />

00470551 . . . . . . . . . . . . . . . . . . . . . . . . . . 218<br />

00470608 . . . . . . . . . . . . . . . . . . . . . . . . . . 218<br />

00470652 . . . . . . . . . . . . . . . . . . . . . . . 36, 216<br />

00470988 . . . . . . . . . . . . . . . . . . . . . . . . 13-14<br />

00471420 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9<br />

00471422 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9<br />

00471440 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8<br />

00471441 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8<br />

00472014 . . . . . . . . . . . . . . . . . . . . . . . . 13-14<br />

00472020 . . . . . . . . . . . . . . . . . . . . . . . . . . 221<br />

00472022 . . . . . . . . . . . . . . . . . . . . . . . . . . 221<br />

00473194 . . . . . . . . . . . . . . . . . . 197, 229-230<br />

00473292 . . . . . . . . . . . . . . . . . . . . . . 195, 220<br />

00473449 . . . . . . . . . . . . . . . . . . . . . . . . . . 218<br />

00473539 . . . . . . . . . . . . . . . . . . . . . . 198, 223<br />

00473543 . . . . . . . . . . . . . . . . . . . . . . 198, 223<br />

00473550 . . . . . . . . . . . . . . . . . . . . . . 199, 224<br />

00473552 . . . . . . . . . . . . . . . . . . . . . . 199, 224<br />

00473578 . . . . . . . . . . . . . . . . . . . . . . . . . . 223<br />

00570194 . . . . . . . . . . . . . . . . . . . . . . . . . . . 45<br />

00570559 . . . . . . . . . . . . . . . . . . . . . . . . . . . 37<br />

00570567 . . . . . . . . . . . . . . . . . . . . . . . . . . . 37<br />

00570948 . . . . . . . . . . . . . . . . . . . . . . . . 13-14<br />

00570957 . . . . . . . . . . . . . . . . . . . . . . . . . . . 17<br />

00570984 . . . . . . . . . . . . . . . . . . . . . . . . 13-14<br />

00572561 . . . . . . . . . . . . . . . . . . . . . . . . 13-15<br />

00572615 . . . . . . . . . . . . . . . . . . . . . . . . 13-14<br />

00572616 . . . . . . . . . . . . . . . . . . . . . . . . . . . 14<br />

00572624 . . . . . . . . . . . . . . . . . . . . . . . . 13-14<br />

00572695 . . . . . . . . . . . . . . . . . . . . . . . . 13-14<br />

00572737 . . . . . . . . . . . . . . . . . . . . . . . . . . . 14<br />

00873032 . . . . . . . . . . . . . . . . . . . . . . . . . . 323<br />

00873035 . . . . . . . . . . . . . . . . . . . . . . . . . . 327<br />

00873036 . . . . . . . . . . . . . . . . . . . . . . . . . . 327<br />

00890873 . . . . . . . . . . . . . . . . . . . . . . . . . . 323<br />

00890893 . . . . . . . . . . . . . . . . . . . . . . . . . . 292<br />

00890945 . . . . . . . . . . . . . . . . . . . . . . . . . . 323<br />

00891480 . . . . . . . . . . . . . . . . . . . . . . . . . . 327<br />

00891542 . . . . . . . . . . . . . . . . . . . . . . . . . . 292<br />

00891543 . . . . . . . . . . . . . . . . . . . . . . . . . . 292<br />

00891544 . . . . . . . . . . . . . . . . . . . . . . . . . . 292<br />

01541498 . . . . . . . . . . . . . . . . . . . . . . 354-355<br />

01860436 . . . . . . . . . . . . . . . . . . . . . . . . . . 259<br />

01860449 . . . . . . . . . . . . . . . . . . . . . . . . . . 260<br />

01860470 . . . . . . . . . . . . . . . . . . . . . . . . . . 260<br />

018i60794. . . . . . . . . . . . . . . . . . . . . . . . . . 252<br />

01861854 . . . . . . . . . . . . . . . . . . . . . . . . . . 256<br />

01861861 . . . . . . . . . . . . . . . . . . . . . . . . . . 256<br />

01861862 . . . . . . . . . . . . . . . . . . . . . . . . . . 256<br />

01862289 . . . . . . . . . . . . . . . . . . . . . . . . . . 259<br />

01862292 . . . . . . . . . . . . . . . . . . . . . . . . . . 259<br />

01862295 . . . . . . . . . . . . . . . . . . . . . . . . . . 259<br />

01862301 . . . . . . . . . . . . . . . . . . . . . . . . . . 257<br />

01862812 . . . . . . . . . . . . . . . . . . . . . . . . . . 252<br />

02190041 . . . . . . . . . . . . . . . . . . . . . . . . . . 342<br />

02190042 . . . . . . . . . . . . . . . . . . . . . . . . . . 342<br />

02190045 . . . . . . . . . . . . . . . . . . . . . . . . . . 350<br />

02190048 . . . . . . . . . . . . . . . . . . . . . . . . . . 344<br />

02190061 . . . . . . . . . . . . . . . . . . . . . . . . . . . 80<br />

02190062 . . . . . . . . . . . . . . . . . . . . . . . . . . 339<br />

02190071 . . . . . . . . . . . . . . . . . . . . . . . . . . 368<br />

02190080 . . . . . . . . . . . . . . . . . . . . . . 339, 372<br />

02190136 . . . . . . . . . . . . . . . . . . . . . . . . . . 350<br />

02191269 . . . . . . . . . . . . . . . . . . . . . . . . . . 366<br />

02191858 . . . . . . . . . . . . . . . . . . . . . . . . . . 366<br />

02200550 . . . . . . . . . . . . . . . . . . . . . . . . . . 249<br />

02400011 . . . . . . . . . . . . . . . . . . . . . . . . . . 355<br />

02400084 . . . . . . . . . . . . . . . . . . . . . . . 77, 354<br />

02400085 . . . . . . . . . . . . . . . . . . . . . . . . . . 355<br />

02400115 . . . . . . . . . . . . . . . . . . . . . . . . 76, 78<br />

02400117 . . . . . . . . . . . . . . . . . . . . . . . . . . . 78<br />

02400119 . . . . . . . . . . . . . . . . . . . . . . . . 76, 78<br />

02400137 . . . . . . . . . . . . . . . . . . . . . . . . 81-82<br />

02400642 . . . . . . . . . . . . . . . . . . . . . . . . . . . 80<br />

02400815 . . . . . . . . . . . . . . . . . . . . . . . . . . . 78<br />

02401028 . . . . . . . . . . . . . . . . . . . . . . . . 81-82<br />

02401042 . . . . . . . . . . . . . . . . . . . . . . . . 81-82<br />

02401092 . . . . . . . . . . . . . . . . . . . . . . . . . . . 78<br />

02401117 . . . . . . . . . . . . . . . . . . . . . . . . . . . 78<br />

02401118 . . . . . . . . . . . . . . . . . . . . . . . . . . . 78<br />

02401119 . . . . . . . . . . . . . . . . . . . . . . . . 76, 78<br />

02401120 . . . . . . . . . . . . . . . . . . . . . . . . 76, 80<br />

02401121 . . . . . . . . . . . . . . . . . . . . . . . . 76, 80<br />

02401286 . . . . . . . . . . . . . . . . . . . . . . . . . . . 80<br />

02401291 . . . . . . . . . . . . . . . . . . . . . . . . . . . 83<br />

02401293 . . . . . . . . . . . . . . . . . . . . . . . . . . . 83<br />

02401294 . . . . . . . . . . . . . . . . . . . . . . . . . . . 82<br />

02401296 . . . . . . . . . . . . . . . . . . . . . . . . . . . 80<br />

02401344 . . . . . . . . . . . . . . . . . . . . . . . . . . . 78<br />

02401347 . . . . . . . . . . . . . . . . . . . . . . . . . . . 80<br />

02401362 . . . . . . . . . . . . . . . . . . . . . . . . 76, 78<br />

02401583 . . . . . . . . . . . . . . . . . . . . . . . . 81-82<br />

02402087 . . . . . . . . . . . . . . . . . . . . . . . . . . . 83<br />

02402089 . . . . . . . . . . . . . . . . . . . . . . . . . . . 83<br />

02450972 . . . . . . . . . . . . . . . . . . . . . . . . . . . 94<br />

02506483 . . . . . . . . . . . . . . . . . . 167, 223, 318<br />

02506495 . . . . . . . . . . . . . . . . . . . . . . . . . . 273<br />

02506516 . . . . . . . . . . . . . . . . . . 221, 229-230<br />

02506517 . . . . . . . . . . . . . . . . . . 221, 229-230<br />

02506518 . . . . . . . . . . . . . . . . . . . . . . . . . . 167<br />

02506519 . . . . . . . . . . . . . . . . . . . . . . . . . . 218<br />

02506532 . . . . . . . . . . . . . . . . . . . . . . 218, 226<br />

02507907 . . . . . . . . . . 357-358, 360, 363, 366<br />

02507987 . . . . . . . . . . . . . . . . . . . . . . . . . . . 13<br />

02507999 . . . . . . . . . . . . . . . . . . . . . . . . . . 243<br />

02508059 . . . . . . . . . . . . . . . . . . . . . . . . . . 226<br />

02508063 . . . . . . . . . . . . . . . . . . . . . . 243-244<br />

02508065 . . . . . . . . . . . . . . . . . . . . . . . . . . 243<br />

02508080 . . . . . . . . . . . . . . . . . . . . . . . . . . 199<br />

02509115 . . . . . . . . . . . . . . . . . . . . . . . . . . 216<br />

02540142 . . . . . . . . . . . . . . . . . . . . . . . . . . 324<br />

02540177 . . . . . . . . . . . . . . . . . . . . . . 319-320<br />

02540197 . . . . . . . . . . . . . . . . . . . . . . 319-320<br />

02540272 . . . . . . . . . . . . . . . . . . . . . . . . . . 321<br />

02540273 . . . . . . . . . . . . . . . . . . . . . . . . . . 323<br />

02540274 . . . . . . . . . . . . . . . . . . . . . . . . . . 323<br />

02540311 . . . . . . . . . . . . . . . . . . . . . . . . . . 322<br />

02540582 . . . . . . . . . . . . . . . . . . . . . . . . . . 273<br />

02540838 . . . . . . . . . . . . . . . . . . . . . . . . . . 327<br />

02540871 . . . . . . . . . . . . . . . . . . . . . . . . . . 321<br />

02541946 . . . . . . . . . . . . . . . . . . . . . . . . . . 325<br />

02542076 . . . . . . . . . . . . . . . . . . . . . . 319-320<br />

02542313 . . . . . . . . . . . . . . . . . . . . . . 319-320<br />

02542782 . . . . . . . . . . . . . . . . . . . . . . . . . . 327<br />

02542783 . . . . . . . . . . . . . . . . . . . . . . . . . . 327<br />

02580164 . . . . . . . . . . . . . . . . . . . . . . . . . . 289<br />

02580166 . . . . . . . . . . . . . . . . . . . . . . . . . . 289<br />

02580167 . . . . . . . . . . . . . . . . . . . . . . . . . . 289<br />

02580168 . . . . . . . . . . . . . . . . . . . . . . . . . . 289<br />

02580169 . . . . . . . . . . . . . . . . . . . . . . . . . . 289<br />

02580191 . . . . . . . . . . . . . . . . . . . . . . . . . . 289<br />

02580192 . . . . . . . . . . . . . . . . . . . . . . . . . . 289<br />

02580194 . . . . . . . . . . . . . . . . . . . . . . . . . . 289<br />

02580195 . . . . . . . . . . . . . . . . . . . . . . . . . . 289<br />

02580202 . . . . . . . . . . . . . . . . . . . . . . . . . . 289<br />

02580203 . . . . . . . . . . . . . . . . . . . . . . . . . . 289<br />

02580213 . . . . . . . . . . . . . . . . . . . . . . . . . . 289<br />

02711441 . . . . . . . . . . . . . . . . . . . . . . . . . . 327<br />

02712273 . . . . . . . . . . . . . . . . . . . . . . . . . . 315<br />

02900540 . . . . . . . . . . . . . . . . . . . . . . . . . . . 67<br />

02901518 . . . . . . . . . . . . . . . . . . . . . . . . . . . 45<br />

02901624 . . . . . . . . . . . . . . . . . . . . . . . . . . 354<br />

03030106 . . . . . . . . . . . . . . . . . . . . . . . . . . . 38<br />

03030130 . . . . . . . . . . . . . . . . . . . . . . . . . . . 14<br />

03030135 . . . . . . . . . . . . . . . . . . . . . . . . . . . 18<br />

03030204 . . . . . . . . . . . . . . . . . . . . . . . . . . . 38<br />

03030264 . . . . . . . . . . . . . . . . . . . . . . . . . . . 38<br />

03030284 . . . . . . . . . . . . . . . . . . . . . . . . . . . 38<br />

03030299 . . . . . . . . . . . . . . . . . . . . . . . . . . . 17<br />

03030313 . . . . . . . . . . . . . . . . . . . . . . . . . . 216<br />

03030314 . . . . . . . . . . . . . . . . . . . . . . . . . . 216<br />

03030352 . . . . . . . . . . . . . . . . . . . . . . . . 17, 20<br />

03030353 . . . . . . . . . . . . . . . . . . . . . . . . . . . 20<br />

03030354 . . . . . . . . . . . . . . . . . . . . . . . . . . . 17<br />

03030402 . . . . . . . . . . . . . . . . . . . . . . . . . . . 17<br />

03030404 . . . . . . . . . . . . . . . . . . . . . . . . . . . 17<br />

03030405 . . . . . . . . . . . . . . . . . . . . . . . . . . . 18<br />

03030406 . . . . . . . . . . . . . . . . . . . . . . . 38, 217<br />

03030433 . . . . . . . . . . . . . . . . . . . . . . . . . . . 17<br />

03030791 . . . . . . . . . . . . . . . . . . . . . . . . . . . 48<br />

03030793 . . . . . . . . . . . . . . . . . . . . . . . . . . . 48<br />

03030952 . . . . . . . . . . . . . . . . . . . . . . . . . . . 48<br />

03030972 . . . . . . . . . . . . . . . . . . . . . . . . . . . 48<br />

03030997 . . . . . . . . . . . . . . . . . . . . . . . . . . . 48<br />

03030998 . . . . . . . . . . . . . . . . . . . . . . . . . . . 48<br />

03031456 . . . . . . . . . . . . . . . . . . . . . . . . . . . 20<br />

03031460 . . . . . . . . . . . . . . . . . . . . . . . . . . . 20<br />

03031573 . . . . . . . . . . . . . . . . . . . . . . . . 13-15<br />

03031802 . . . . . . . . . . . . . . . . . . . . . . . . . . . 20<br />

03031806 . . . . . . . . . . . . . . . . . . . . . . . . . . . 20<br />

03031808 . . . . . . . . . . . . . . . . . . . . . . . . . . . 20<br />

03031810 . . . . . . . . . . . . . . . . . . . . . . . . . . . 17<br />

03031812 . . . . . . . . . . . . . . . . . . . . . . . . . . . 20<br />

03031910 . . . . . . . . . . . . . . . . . . . . . . . 38, 217<br />

03031920 . . . . . . . . . . . . . . . . . . . . . . . . . . . 17<br />

03033124 . . . . . . . . . . . . . . . . . . . . . . . . . . . 17<br />

03190021 . . . . . . . . . . . . . . . . . . . . . . . . . . 341<br />

03190024 . . . . . . . . . . . . . . . . . . . . . . . . . . 343<br />

03190025 . . . . . . . . . . . . . . . . . . . . . . . . . . 343<br />

03190026 . . . . . . . . . . . . . . . . . . . . . . . . . . 342<br />

03190029 . . . . . . . . . . . . . . . . . . . . . . 340-341<br />

03190030 . . . . . . . . . . . . . . . . . . . . . . . . . . 351<br />

03190031 . . . . . . . . . . . . . . . . . . . . . . . . . . 351<br />

03190033 . . . . . . . . . . . . . . . . . . 350, 366-367<br />

03190034 . . . . . . . . . . . . . . . . . . . . . . 350, 367<br />

03190035 . . . . . . . . . . . . . . . . . . . . . . 350, 367<br />

Part No. Page Part No. Page Part No. Page<br />

See page 4 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

See page 2 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong>


Index Part Number 03190036 – 09290148<br />

Index<br />

Part Number<br />

408<br />

03190036 . . . . . . . . . . . . . . . . . . 350, 366-367<br />

03190062 . . . . . . . . . . . . . . . . . . . . . . . . . . 350<br />

03190205 . . . . . . . . . . . . . . . . . . . . . . . . . . 347<br />

03190206 . . . . . . . . . . . . . . . . . . . . . . . . . . 347<br />

03190207 . . . . . . . . . . . . . . . . . . . . . . . . . . 347<br />

03190208 . . . . . . . . . . . . . . . . . . . . . . . . . . 347<br />

03190218 . . . . . . . . . . . . . . . . . . . . . . 340-341<br />

03190236 . . . . . . . . . . . . . . . . . . . . . . 341, 351<br />

03190247 . . . . . . . . . . . . . . . . . . . . . . . . . . 347<br />

03190253 . . . . . . . . . . . . . . . . . . . . . . . . . . 369<br />

03190264 . . . . . . . . . . . . . . . . . . . . . . . . . . 372<br />

03190265 . . . . . . . . . . . . . . . . . . . . . . . . . . 371<br />

03190461 . . . . . . . . . . . . . . . . . . . . . . . . . . 364<br />

03191024 . . . . . . . . . . . . . . . . . . . . . . . . . . 348<br />

03191047 . . . . . . . . . . . . . . . . . . . . . . . . . . 341<br />

03191527 . . . . . . . . . . . . . . . . . . . . . . . . . . 347<br />

03191628 . . . . . . . . . . . . . . . . . . . . . . . . . . 369<br />

03191705 . . . . . . . . . . . . . . . . . . . . . . . . . . 364<br />

03191719 . . . . . . . . . . . . . . . . . . . . . . . . . . 347<br />

03191720 . . . . . . . . . . . . . . . . . . . . . . . . . . 347<br />

03220067 . . . . . . . . . . . . . . . . . . . . . . . . . . 375<br />

03220068 . . . . . . . . . . . . . . . . . . . . . . . . . . 375<br />

03300806 . . . . . . . . . . . . . . . . . . . . . . . . . . 271<br />

03300865 . . . . . . . . . . . . . . . . . . . . . . . . . . 140<br />

03300866 . . . . . . . . . . . . . . . . . . . . . . . . . . 140<br />

03300904 . . . . . . . . . . . . . . . . . . . . . . . . . . 150<br />

03300905 . . . . . . . . . . . . . . . . . . . . . . . . . . 153<br />

03302775 . . . . . . . . . . . . . . . . . . . . . . . . . . 140<br />

03302777 . . . . . . . . . . . . . . . . . . . . . . . . . . 140<br />

03302778 . . . . . . . . . . . . . . . . . . . . . . . . . . 140<br />

03302973 . . . . . . . . . . . . . . . . . . . . . . . . . . 140<br />

03302976 . . . . . . . . . . . . . . . . . . . . . . . . . . 140<br />

03302979 . . . . . . . . . . . . . . . . . . . . . . . . . . 140<br />

03302989 . . . . . . . . . . . . . . . . . . . . . . . . . . 140<br />

03303598 . . . . . . . . . . . . . . . . . . . . . . . . . . 140<br />

03303599 . . . . . . . . . . . . . . . . . . . . . . . . . . 140<br />

03303773 . . . . . . . . . . . . . . . . . . . . . . . . . . 140<br />

04190117 . . . . . . . . . . . . . . . . . . . . . . . . . . 353<br />

04190119 . . . . . . . . . . . . . . . . . . . . . . . . . . 353<br />

04190163 . . . . . . . . . . . . . . . . . . . . . . . . . . 353<br />

04190165 . . . . . . . . . . . . . . . . . . . . . . . . . . 353<br />

04190166 . . . . . . . . . . . . . . . . . . . . . . . . . . 353<br />

04190197 . . . . . . . . . . . . . . . . . . . . . . 353, 364<br />

04190217 . . . . . . . . . . . . . . . . . . . . . . . . . . 353<br />

04190226 . . . . . . . . . . . . . . . . . . . . . . . . . . . 77<br />

04190299 . . . . . . . . . . . . . . . . . . . . . . . . . . 351<br />

04190367 . . . . . . . . . . . . . . . . . . . . . . . . . . 348<br />

04190387 . . . . . . . . . . . . . . . . . . . . . . . . . . 353<br />

04190388 . . . . . . . . . . . . . . . . . . . . . . . . . . 353<br />

04191228 . . . . . . . . . . . . . . . . . . . . . . . . . . 353<br />

04191290 . . . . . . . . . . . . . . . . . . . . . . . . . . 353<br />

04191291 . . . . . . . . . . . . . . . . . . . . . . . . . . 353<br />

04191577 . . . . . . . . . . . . . . . . . . . . . . . . . . 348<br />

04191838 . . . . . . . . . . . . . . . . . . . . . . . . . . 353<br />

04191839 . . . . . . . . . . . . . . . . . . . . . . . . . . 353<br />

04308523 . . . . . . . . . . . . . . . . . . . . . . . . . . 138<br />

04800514 . . . . . . . . . . . . . . . . . . . . . . . . . . 258<br />

04810949 . . . . . . . . . . . . . . . . . . . . . . . . . . 258<br />

04820519 . . . . . . . . . . . . . . . . . . . . . . . . . . 258<br />

04821008 . . . . . . . . . . . . . . . . . . . . . . 248, 251<br />

04821131 . . . . . . . . . . . . . . . . . . . . . . 248, 251<br />

04821132 . . . . . . . . . . . . . . . . . . . . . . 248, 251<br />

04960691 . . . . . . . . . . . . . . . . . . . . . . . . . . 257<br />

04967843 . . . . . . . . . . . . . . . . . . . . . . . . . . 257<br />

04967845 . . . . . . . . . . . . . . . . . . . . . . 250, 257<br />

04967854 . . . . . . . . . . . . . . . . . . . . . . . . . . 257<br />

04969486 . . . . . . . . . . . . . . . . . . . . . . . . . . 315<br />

04970343 . . . . . . . . . . . . . . . . . . . . . . 181, 183<br />

04970573 . . . . . . . . . . . . . . . . . . . . . . . . . . 242<br />

04970839 . . . . . . . . . . . . . . . . . . . . . . . . . . 242<br />

04972066 . . . . . . . . . . . . . . . . . . . . . . . . . . 183<br />

04972383 . . . . . . . . . . . . . . . . . . . . . . . . . . 181<br />

04972392 . . . . . . . . . . . . . . . . . . . . . . . . . . . 94<br />

04973727 . . . . . . . . . . . . . . . . . . . . . . . . . . 181<br />

04974018 . . . . . . . . . . . . . . . . . . . . . . . . . . 183<br />

04974414 . . . . . . . . . . . . . . . . . . . . . . . . . . 180<br />

04974438 . . . . . . . . . . . . . . . . . . . . . . . . . . 260<br />

04977032 . . . . . . . . . . . . . . . . . . . . . . . . . . 258<br />

04977042 . . . . . . . . . . . . . . . . . . . . . . . . . . 258<br />

04977043 . . . . . . . . . . . . . . . . . . . . . . . . . . 257<br />

04978443 . . . . . . . . . . . . . . . . . . . . . . . . . . 258<br />

04978444 . . . . . . . . . . . . . . . . . . . . . . . . . . 258<br />

04978581 . . . . . . . . . . . . . . . . . . . . . . . . . . 241<br />

04978582 . . . . . . . . . . . . . . . . . . . . . . . . . . 241<br />

04978590 . . . . . . . . . . . . . . . . . . . . . . . . . . 241<br />

04994506 . . . . . . . . . . . . . . . . . . . . . . . . . . 240<br />

04994507 . . . . . . . . . . . . . . . . . . . . . . . . . . 240<br />

07110001 . . . . . . . . . . . . . . . . . . . . . . . . . . 286<br />

07110002 . . . . . . . . . . . . . . . . . . . . . . . . . . 286<br />

07110003 . . . . . . . . . . . . . . . . . . . . . . . . . . 286<br />

07110004 . . . . . . . . . . . . . . . . . . . . . . . . . . 287<br />

07110005 . . . . . . . . . . . . . . . . . . . . . . . . . . 287<br />

07110006 . . . . . . . . . . . . . . . . . . . . . . . . . . 287<br />

07110013 . . . . . . . . . . . . . . . . . . . . . . . . . . 286<br />

07110014 . . . . . . . . . . . . . . . . . . . . . . . . . . 286<br />

07110015 . . . . . . . . . . . . . . . . . . . . . . . . . . 286<br />

07110016 . . . . . . . . . . . . . . . . . . . . . . . . . . 287<br />

07110017 . . . . . . . . . . . . . . . . . . . . . . . . . . 287<br />

07110018 . . . . . . . . . . . . . . . . . . . . . . . . . . 287<br />

07110019 . . . . . . . . . . . . . . . . . . . . . . . . . . 286<br />

07110020 . . . . . . . . . . . . . . . . . . . . . . . . . . 286<br />

07110021 . . . . . . . . . . . . . . . . . . . . . . . . . . 286<br />

07110022 . . . . . . . . . . . . . . . . . . . . . . . . . . 287<br />

07110023 . . . . . . . . . . . . . . . . . . . . . . . . . . 287<br />

07110024 . . . . . . . . . . . . . . . . . . . . . . . . . . 287<br />

07110025 . . . . . . . . . . . . . . . . . . . . . . . . . . 286<br />

07110027 . . . . . . . . . . . . . . . . . . . . . . . . . . 286<br />

07110029 . . . . . . . . . . . . . . . . . . . . . . . . . . 287<br />

07110031 . . . . . . . . . . . . . . . . . . . . . . . . . . 286<br />

07110032 . . . . . . . . . . . . . . . . . . . . . . . . . . 286<br />

07110033 . . . . . . . . . . . . . . . . . . . . . . . . . . 286<br />

07110035 . . . . . . . . . . . . . . . . . . . . . . . . . . 287<br />

07110037 . . . . . . . . . . . . . . . . . . . . . . . . . . 286<br />

07110039 . . . . . . . . . . . . . . . . . . . . . . . . . . 286<br />

07110041 . . . . . . . . . . . . . . . . . . . . . . . . . . 287<br />

07110043 . . . . . . . . . . . . . . . . . . . . . . . . . . 286<br />

07110045 . . . . . . . . . . . . . . . . . . . . . . . . . . 286<br />

07110047 . . . . . . . . . . . . . . . . . . . . . . . . . . 287<br />

07110055 . . . . . . . . . . . . . . . . . . . . . . . . . . 286<br />

07110056 . . . . . . . . . . . . . . . . . . . . . . . . . . 286<br />

07110057 . . . . . . . . . . . . . . . . . . . . . . . . . . 286<br />

07110058 . . . . . . . . . . . . . . . . . . . . . . . . . . 287<br />

07110059 . . . . . . . . . . . . . . . . . . . . . . . . . . 287<br />

07110060 . . . . . . . . . . . . . . . . . . . . . . . . . . 287<br />

07110061 . . . . . . . . . . . . . . . . . . . . . . . . . . 286<br />

07110062 . . . . . . . . . . . . . . . . . . . . . . . . . . 286<br />

07110064 . . . . . . . . . . . . . . . . . . . . . . . . . . 287<br />

07110073 . . . . . . . . . . . . . . . . . . . . . . . . . . 286<br />

07110074 . . . . . . . . . . . . . . . . . . . . . . . . . . 286<br />

07110075 . . . . . . . . . . . . . . . . . . . . . . . . . . 286<br />

07110077 . . . . . . . . . . . . . . . . . . . . . . . . . . 287<br />

07110085 . . . . . . . . . . . . . . . . . . . . . . . . . . 286<br />

07110086 . . . . . . . . . . . . . . . . . . . . . . . . . . 292<br />

07110087 . . . . . . . . . . . . . . . . . . . . . . . . . . 286<br />

07110088 . . . . . . . . . . . . . . . . . . . . . . . . . . 292<br />

07110089 . . . . . . . . . . . . . . . . . . . . . . . . . . 287<br />

07110090 . . . . . . . . . . . . . . . . . . . . . . . . . . 292<br />

07110091 . . . . . . . . . . . . . . . . . . . . . . . . . . 286<br />

07110092 . . . . . . . . . . . . . . . . . . . . . . . . . . 292<br />

07110093 . . . . . . . . . . . . . . . . . . . . . . . . . . 286<br />

07110095 . . . . . . . . . . . . . . . . . . . . . . . . . . 287<br />

07110096 . . . . . . . . . . . . . . . . . . . . . . . . . . 292<br />

07110098 . . . . . . . . . . . . . . . . . . . . . . . . . . 292<br />

07110100 . . . . . . . . . . . . . . . . . . . . . . . . . . 292<br />

07110102 . . . . . . . . . . . . . . . . . . . . . . . . . . 292<br />

07110105 . . . . . . . . . . . . . . . . . . . . . . . . . . 292<br />

07110106 . . . . . . . . . . . . . . . . . . . . . . . . . . 292<br />

07110114 . . . . . . . . . . . . . . . . . . . . . . . . . . 290<br />

07110115 . . . . . . . . . . . . . . . . . . . . . . . . . . 286<br />

07110117 . . . . . . . . . . . . . . . . . . . . . . . . . . 286<br />

07110119 . . . . . . . . . . . . . . . . . . . . . . . . . . 287<br />

07110121 . . . . . . . . . . . . . . . . . . . . . . . . . . 286<br />

07110123 . . . . . . . . . . . . . . . . . . . . . . . . . . 286<br />

07110145 . . . . . . . . . . . . . . . . . . . . . . . . . . 286<br />

07110163 . . . . . . . . . . . . . . . . . . . . . . . . . . 290<br />

07110165 . . . . . . . . . . . . . . . . . . . . . . . . . . 290<br />

07110166 . . . . . . . . . . . . . . . . . . . . . . . . . . 290<br />

07110189 . . . . . . . . . . . . . . . . . . . . . . . . . . 290<br />

07110190 . . . . . . . . . . . . . . . . . . . . . . . . . . 290<br />

07110191 . . . . . . . . . . . . . . . . . . . . . . . . . . 290<br />

07110192 . . . . . . . . . . . . . . . . . . . . . . . . . . 290<br />

07110231 . . . . . . . . . . . . . . . . . . . . . . . . . . 287<br />

07110232 . . . . . . . . . . . . . . . . . . . . . . . . . . 286<br />

07110233 . . . . . . . . . . . . . . . . . . . . . . . . . . 287<br />

07110234 . . . . . . . . . . . . . . . . . . . . . . . . . . 286<br />

07110235 . . . . . . . . . . . . . . . . . . . . . . . . . . 286<br />

07110236 . . . . . . . . . . . . . . . . . . . . . . . . . . 287<br />

07120001 . . . . . . . . . . . . . . . . . . . . . . . . . . 311<br />

07120005 . . . . . . . . . . . . . . . . . . . . . . . . . . 311<br />

07120012 . . . . . . . . . . . . . . . . . . . . . . . . . . 311<br />

07120016 . . . . . . . . . . . . . . . . . . . . . . . . . . 311<br />

07120019 . . . . . . . . . . . . . . . . . . . . . . . . . . 311<br />

07120023 . . . . . . . . . . . . . . . . . . . . . . . . . . 311<br />

07120033 . . . . . . . . . . . . . . . . . . . . . . . . . . 309<br />

07120040 . . . . . . . . . . . . . . . . . . . . . . . . . . 309<br />

07120073 . . . . . . . . . . . . . . . . . . . . . . . . . . 309<br />

07120096 . . . . . . . . . . . . . . . . . . . . . . . . . . 309<br />

07120097 . . . . . . . . . . . . . . . . . . . . . . . . . . 309<br />

07120099 . . . . . . . . . . . . . . . . . . . . . . . . . . 309<br />

07150001 . . . . . . . . . . . . . . . . . . . . . . . . . . 293<br />

07150002 . . . . . . . . . . . . . . . . . . . . . . . . . . 293<br />

07150005 . . . . . . . . . . . . . . . . . . . . . . . . . . 293<br />

07150006 . . . . . . . . . . . . . . . . . . . . . . . . . . 293<br />

07150012 . . . . . . . . . . . . . . . . . . . . . . . . . . 292<br />

07150013 . . . . . . . . . . . . . . . . . . . . . . 208, 293<br />

07150014 . . . . . . . . . . . . . . . . . . . . . . . . . . 293<br />

07150015 . . . . . . . . . . . . . . . . . . . . . . . . . . 293<br />

07150016 . . . . . . . . . . . . . . . . . . . . . . 291, 293<br />

07150017 . . . . . . . . . . . . . . . . . . . . . . . . . . 293<br />

07150018 . . . . . . . . . . . . . . . . . . . . . . 291, 293<br />

07150019 . . . . . . . . . . . . . . . . . . . . . . . . . . 293<br />

07150020 . . . . . . . . . . . . . . . . . . . . . . . . . . 293<br />

07150021 . . . . . . . . . . . . . . . . . . . . . . . . . . 293<br />

07150022 . . . . . . . . . . . . . . . . . . . . . . . . . . 293<br />

07150023 . . . . . . . . . . . . . . . . . . . . . . . . . . 292<br />

07150024 . . . . . . . . . . . . . . . . . . . . . . . . . . 292<br />

07150025 . . . . . . . . . . . . . . . . . . . . . . . . . . 293<br />

07150026 . . . . . . . . . . . . . . . . . . . . . . . . . . 292<br />

07150028 . . . . . . . . . . . . . . . . . . . . . . . . . . 293<br />

07150029 . . . . . . . . . . . . . . . . . . . . . . . . . . 293<br />

07150030 . . . . . . . . . . . . . . . . . . . . . . . . . . 293<br />

07150031 . . . . . . . . . . . . . . . . . . . . . . . . . . 293<br />

07150032 . . . . . . . . . . . . . . . . . . . . . . . . . . 293<br />

09200010 . . . . . . . . . . . . . . . . . . . . . . . . . . 245<br />

09200011 . . . . . . . . . . . . . . . . . . . . . . . . . . 245<br />

09200012 . . . . . . . . . . . . . . . . . . . . . . . . . . 245<br />

09200013 . . . . . . . . . . . . . . . . . . . . . . . . . . 245<br />

09200017 . . . . . . . . . . . . . . . . . . . . . . . . . . 245<br />

09200091 . . . . . . . . . . . . . . . . . . . . . . 144, 183<br />

09210011 . . . . . . . . . . 193, 195, 201-202, 205<br />

09210012 . . . . . . . . . . . . . . 193, 195, 201, 205<br />

09290144 . . . . . . . . . . . . . . . . . . . . . . 177, 331<br />

09290145 . . . . . . . . . . . . . . . . . . . . . . 177, 331<br />

09290146 . . . . . . . . . . . . . . . . . . . . . . . . . . 177<br />

09290147 . . . . . . . . . . . . . . . . . . . . . . . . . . 177<br />

09290148 . . . . . . . . . . . . . . . . . . . . . . . . . . 331<br />

Part No. Page Part No. Page Part No. Page


09290149 – 09985727 Part Number Index<br />

Index<br />

Part Number<br />

409<br />

09290149 . . . . . . . . . . . . . . . . . . . . . . . . . . 331<br />

09410015 . . . . . . . . . . . . . . . . . . . . . . . . . . 331<br />

09410020 . . . . . . . . . . . . . . . . . . . . . . . . . . 331<br />

09410036 . . . . . . . . . . . . . . . . . . . . . . 316, 331<br />

09410047 . . . . . . . . . . . . . . . . . . . . . . . . . . 206<br />

09410077 . . . . . . . . . . . . . . . . . . . . . . . . . . 175<br />

09421018 . . . . . . . . . . . . . . . . . . . . . . . . . . . 77<br />

09421019 . . . . . . . . . . . . . . . . . . . . . . . . . . . 77<br />

09421021 . . . . . . . . . . . . . . . . . . . . . . . . . . . 77<br />

09902005 . . . . . . . . . . . . . . . . . . . . . . . . . . . 20<br />

09902006 . . . . . . . . . . . . . . . . . . . . . . 228-229<br />

09902015. . . . . . . . . . . . . 17-19, 226, 228-229<br />

09902018 . . . . . . . . . . . . . . . . . . . . . . . . . . 320<br />

09902031 . . . . . . . . . . . . . . . . . . . . . . . . . . 369<br />

09902033 . . . . . . . . . . . . . . . . . . . . . . 198, 223<br />

09902035 . . . . . . . . . . . . . . . . . . . . . . . . . . . 81<br />

09902048 . . . . . . . . . . . . . . . . . . . . . . . . . . . 81<br />

09902102 . . . . . . . . . . . . . . . . . . . . . . . 20, 350<br />

09902123 . . . . . . . . . . . . . . . . . . . . . . . . . . . 81<br />

09902128 . . . . . . . . . . . . . . . . . . . . . . 319-320<br />

09902131 . . . . . . . . . . . . . . . . . . . . . . . . . . 369<br />

09902143 . . . . . . . . . . . . . . . . . . . . . . 132-133<br />

09902147 . . . . . . . . . . . . . . . . . . . . . . . . 13-14<br />

09902152 . . . . . . . . . . . . . . . . . . . . . . . . . . 228<br />

09902153 . . . . . . . . . . . . . . . . . . . . . . . . . . 197<br />

09902155 . . . . . . . . . . . . . . . . . . . . . . 228-230<br />

09902163 . . . . . . . . . . . . . . . . . . . . . . . . . . 369<br />

09902188 . . . . . . . . . . . . . . . . . . . . . . . . . . . 81<br />

09902205 . . . . . . . . . . . . . . . . . . . . . . . . . . 350<br />

09902206 . . . . . . . . . . . . . . . . . . . . . . . . . . 351<br />

09902207 . . . . . . . . . . . . . . . . . . . . . . 228-230<br />

09902218 . . . . . . . . . . . . . . . . . . . . . . . . . . 193<br />

09902219 . . . . . . . . . . . . . . . . . . . . . . . . 13-15<br />

09902225 . . . . . . . . . . . . . . . . . . . . . . . . . . 228<br />

09902236 . . . . . . . . . . . . . . . . . . . . . . . . 13-14<br />

09902239 . . . . . . . . . . . . . . . . . . . . . . . . . . . 20<br />

09902240 . . . . . . . . . . . . . . . . . . . . . . . . 13-14<br />

09902245 . . . . . . . . . . . . . . . . . . . . . . . . . . 353<br />

09902247 . . . . . . . . . . . . . . 135, 226, 228-230<br />

09902473 . . . . . . . . . . . . . . . . . . . . . . . . . . . 18<br />

09903011 . . . . . . . . . . . . . . . . . . . . . . . . . . 370<br />

09903021 . . . . . . . . . . . . . . . . . . . . . . . . . . 230<br />

09903094 . . . . . . . . . . . . . . . . . . 226, 229-230<br />

09903103 . . . . . . . . . . . . . . . . . . . . . . . . . . 223<br />

09903104 . . . . . . . . . . . . . . . . . . . . . . . . . . 223<br />

09903119 . . . . . . . . . . . . . . . . . . . . . . . . . . 205<br />

09903120 . . . . . . . . . . . . . . . . . . . . . . . . . . 205<br />

09903128 . . . . . . . . . . . . . . . . . . . . . . . . . . 155<br />

09903196 . . . . . . . . . . . . . . . . . . . . . . . . . . 355<br />

09903199 . . . . . . . . . . . . . . . . . . . . . . . . . . 223<br />

09903289 . . . . . . . . . . . . . . . . . . . . . . 273, 323<br />

09903392 . . . . . . . . . . . . . . . . . . . 92, 150, 155<br />

09903394 . . . . . . . . . . . . . . . . . . . . . . . . . . . 94<br />

09903395 . . . . . . . . . . . . . . . . . . . . . . . . . . . 94<br />

09903428 . . . . . . . . . . . . . . . . . . . . . . . . . . 226<br />

09903471 . . . . . . . . . . . . . . . . . . . . . . 223, 355<br />

09903606 . . . . . . . . . . . . . . . . . . . . . . . . . . 322<br />

09903610 . . . . . . . . . . . . . . . . . . . . . . . . . . 322<br />

09903615 . . . . . . . . . . . . . . . . . . 242, 273, 322<br />

09903665 . . . . . . . . . . . . . . . . . . . . . . . . . . . 82<br />

09903673 . . . . . . . . . . . . . . . . . . . . . . . . . . . 82<br />

09903700 . . . . . . . . . . . . . . . . . . . . . . . 94, 147<br />

09903739 . . . . . . . . . . . . . . . . . . . . . . . . 92, 94<br />

09903771 . . . . . . . . . . . . . . . . . . . . . . . . . . 318<br />

09903799 . . . . . . . . . . . . . . . . . . . . . . . . . . . 23<br />

09903807 . . . . . . . . . . . . . . . . . . . . . . . . . . 323<br />

09903890 . . . . . . . . . . . . . . . . . . . . . . . . . . 323<br />

09903891 . . . . . . . . . . . . . . . . . . . . . . . . . . 323<br />

09903906 . . . . . . . . . . . . . . . . . . . . . . . . . . 318<br />

09903915 . . . . . . . . . . . . . . . . . . . . . . . . . . . 94<br />

09903980 . . . . . . . . . . . . . . . . . . . . . . . . . . 323<br />

09903981 . . . . . . . . . . . . . . . . . . . . . . . . . . . 94<br />

09903999 . . . . . . . . . . . . . . . . . . . . . . . . . . 226<br />

09904800 . . . . . . . . . . . . . . . . . . . . . . . . . . 325<br />

09904801 . . . . . . . . . . . . . . . . . . . . . . . . . . 325<br />

09904802 . . . . . . . . . . . . . . . . . . . . . . . . . . 325<br />

09904805 . . . . . . . . . . . . . . . . . . . . . . . . . . 325<br />

09904818 . . . . . . . . . . . . . . . . . . . . . . . . . . 326<br />

09904819 . . . . . . . . . . . . . . . . . . . . . . . . . . 326<br />

09904820 . . . . . . . . . . . . . . . . . . . . . . . . . . 326<br />

09904822 . . . . . . . . . . . . . . . . . . . . . . 161, 327<br />

09904823 . . . . . . . . . . . . . . . . . . . . . . 161, 327<br />

09904827 . . . . . . . . . . . . . . . . . . . . . . . . . . 326<br />

09904845 . . . . . . . . . . . . . . . . . . . . . . . . . . 216<br />

09904846 . . . . . . . . . . . . . . . . . . . . . . 193, 216<br />

09904849 . . . . . . . . . . . . . . . . . . . . . . . . . . 321<br />

09904937 . . . . . . . . . . . . . . . . . . . . . . . . . . 327<br />

09904938 . . . . . . . . . . . . . . . . . . . . . . . . . . 326<br />

09904939 . . . . . . . . . . . . . . . . . . . . . . . . . . 326<br />

09904940 . . . . . . . . . . . . . . . . . . . . . . . . . . 326<br />

09904941 . . . . . . . . . . . . . . . . . . . . . . 161, 327<br />

09904942 . . . . . . . . . . . . . . . . . . . . . . . . . . 326<br />

09904943 . . . . . . . . . . . . . . . . . . . . . . . . . . 327<br />

09904947 . . . . . . . . . . . . . . . . . . . . . . . . . . 323<br />

09904953 . . . . . . . . . . . . . . . . . . . . . . . . . . 325<br />

09904955 . . . . . . . . . . . . . . . . . . . . . . . . . . 325<br />

09904956 . . . . . . . . . . . . . . . . . . . . . . . . . . 323<br />

09904962 . . . . . . . . . . . . . . . . . . . . . . . . . . 325<br />

09904963 . . . . . . . . . . . . . . . . . . . . . . . . . . 325<br />

09904974 . . . . . . . . . . . . . . . . . . . . . . . . . . 323<br />

09904991 . . . . . . . . . . . . . . . . . . . 13, 204, 218<br />

09905147 . . . . . . . . . . . . . . . . . . . . . . . . . . 192<br />

09905932 . . . . . . . . . . . . . . . . . . . . . . . . . . 370<br />

09907120 . . . . . . . . . . . . . . . . . . . . . . . . . . . 36<br />

09907122 . . . . . . . . . . . . . . . . . . . . . . . . . . 216<br />

09907126 . . . . . . . . . . . . . . . . . . . . . . 314, 316<br />

09907127 . . . . . . . . . . . . . . . . . . . . . . . . . . 165<br />

09907128 . . . . . . . . . . . . . . . . . . . . . . . . . . 165<br />

09907204 . . . . . . . . . . . . . . . . . . . . . . . . . . . 82<br />

09907222 . . . . . . . . . . . . . . . . . . . . . . . . . . 137<br />

09907233 . . . . . . . . . . . . . . . . . . . . . . . . . . 145<br />

09907236 . . . . . . . . . . . . . . . . . . . . . . . . . . 353<br />

09907281 . . . . . . . . . . . . . . . . . . . . . . . . . . 366<br />

09907324 . . . . . . . . . . . . . . . . . . . . . . 319-320<br />

09907338 . . . . . . . . . . . . . . . . . . . . . . 319-320<br />

09907339 . . . . . . . . . . . . . . . . . . . . . . 319-320<br />

09907345 . . . . . . . . . . . . . . . . . . . . . . 319-320<br />

09907504 . . . . . . . . . . . . . . . . . . . . . . . . . . 348<br />

09907827 . . . . . . . . . . . . . . . . . . . . . . . . . . 132<br />

09907925 . . . . . . . . . . . . . . . . . . . . . . . . . . . 35<br />

09907998 . . . . . . . . . . . . . . . . . . . . . . . . . . . 88<br />

09908134 . . . . . . . . . . . . . . . . . . . . . . 354-355<br />

09908138 . . . . . . . . . . . . . . . 80, 351, 370, 375<br />

09908265 . . . . . . . . . . . . . . . 18, 193, 223-224<br />

09908396 . . . . . . . . . . . . . . . . . . . . . . . . . . 375<br />

09908397 . . . . . . . . . . . . . . . . . . . . . . 370, 375<br />

09908400 . . . . . . . 80, 351, 353, 366, 370, 375<br />

09908467 . . . . . . . . . . . . . . . . . . . . . . 341, 344<br />

09908522 . . . . . . . . . . . . . . . . . . . . . . . . . . 230<br />

09908587 . . . . . . . . . . . . . . . . . . 193, 199, 224<br />

09908825 . . . . . . . . . . . . . . . . . . . . . . . . . . 366<br />

09908851 . . . . . . . . . . . . . . . . . . . . . . . . . . 181<br />

09910148 . . . . . . . . . . . . . . . . . . . . . . . . 13-14<br />

09911186 . . . . . . . . . . . . . . . . . . 356, 360, 362<br />

09911286 . . . . . . . . . . . . . . . . . . . . . . . . 13-14<br />

09912223 . . . . . . . . . . . . . . . . . . . . . . . . . . 133<br />

09920021 . . . . . . . . . . . . . . . . . . . . . . . . . . 230<br />

09920034 . . . . . . . . . . . . . . . . . . . . . . 229-230<br />

09920104 . . . . . . . . . . . . . . . . . . . . . . . 94, 147<br />

09920105 . . . . . . . . . . . . . . . . . . . . . . . 94, 150<br />

09920107 . . . . . . . . . . . . . . . . . . . . . . . . 92, 94<br />

09920118 . . . . . . . . . . . . . . . . . . . . . . 229-230<br />

09920123 . . . . . . . . . . . . . . . . . . . . . . . . . . . 10<br />

09920124 . . . . . . . . . . . . . . . . . . . . . . . . . . . 10<br />

09920127 . . . . . . . . . . . . . . . . . . . . . . . 94, 147<br />

09920140 . . . . . . . . . . . . . . . . . . . . . . . 94, 150<br />

09920141 . . . . . . . . . . . . . . . . . . . . . . . . 92, 94<br />

09920186 . . . . . . . . . . . . . . . . . . . . . . 223, 226<br />

09920262 . . . . . . . . . . . . . . . . . . . . . . 218, 226<br />

09920301 . . . . . . . . . . . . . . . . . . . . . . 150, 155<br />

09920379 . . . . . . . . . . . . . . . . . . . . . . 193, 204<br />

09920381 . . . . . . . . . . . . . . . . . . . . . . . . . . 273<br />

09920382 . . . . . . . . . . . . . . . . . . . . . . . . . . 273<br />

09920391 . . . . . . . . . . . . . . . . . . . . . . . . . . 273<br />

09920404 . . . . . . . . . . . . . . . . . . . . . . . . . . . 81<br />

09920429 . . . . . . . . . . . . . . . . . . . . . . . . . . 273<br />

09920513 . . . . . . . . . . . . . . . . . . . . . . 273, 323<br />

09920515 . . . . . . . . . . . . . . . . . . 197-198, 223<br />

09920516 . . . . . . . . . . . . . . . . . . . . . . . . . . 198<br />

09920517 . . . . . . . . . . . . . . . . . . . . . . . . . . 198<br />

09920518 . . . . . . . . . . . . . . . . . . . . . . 198, 223<br />

09920528 . . . . . . . . . . . . . . . . . . . . . . . . . . 230<br />

09920545 . . . . . . . . . . . . . . . . . . . . . . . . . . 223<br />

09920546 . . . . . . . . . . . . . . . . . . . . . . . . . . 223<br />

09920593 . . . . . . . . . . . . . . . . . . . . . . . . . . 184<br />

09920672 . . . . . . . . . . . . . . . . . . . . . . . . . . 273<br />

09921004 . . . . . . . . . . . . . . . . . . . . . . . . . . 155<br />

09921018 . . . . . . . . . . . . . . . . . . . . . . . . . . 353<br />

09921019 . . . . . . . . . . . . . . . . . . . . . . . . . . 353<br />

09921028 . . . . . . . . . . . . . . . . . . . . . . 228, 230<br />

09921037 . . . . . . . . . . . . . . . . . . . . . . . . . . 242<br />

09921044 . . . . . . . . . . . . . . . . . . . . . . . . 13-14<br />

09921045 . . . . . . . . . . . . . . . . . . . . . . 198, 223<br />

09923012 . . . . . . . . . . . . . . . . . . . . . . . . . . 230<br />

09923031 . . . . . . . . . . . . . . . . . . . . . . . . . . . 89<br />

09923032 . . . . . . . . . . . . . . . . . . . . . . . . . . . 89<br />

09923078 . . . . . . . . . . . . . . . . . . . . . . 132, 137<br />

09923219 . . . . . . . . . . . . . . . . . . . . . . . . . . 273<br />

09923270 . . . . . . . . . . . . . . . . . . . . . . . . . . 273<br />

09923304 . . . . . . . . . . . . . . . . . . . . . . . . . . 273<br />

09923305 . . . . . . . . . . . . . . . . . . . . . . . . . . 273<br />

09923306 . . . . . . . . . . . . . . . . . . . . . . . . . . 273<br />

09923307 . . . . . . . . . . . . . . . . . . . . . . . . . . 273<br />

09923337 . . . . . . . . . . . . . . . . . . . . . . . . . . 243<br />

09923366 . . . . . . . . . . . . . . . . . . . . . . 319-320<br />

09923367 . . . . . . . . . . . . . . . . . . . . . . 319-320<br />

09923448 . . . . . . . . . . . . . . . . . . . . . . . . . . 199<br />

09923454 . . . . . . . . . . . . . . . . . . . . . . . . . . 354<br />

09923464 . . . . . . . . . . . . . . . . . . . . . . . 36, 216<br />

09923490 . . . . . . . . . . . . . . . . . . . . . . . . . . 137<br />

09923491 . . . . . . . . . . . . . . . . . . . . . . . . . . 137<br />

09923492 . . . . . . . . . . . . . . . . . . . . . . . . . . 137<br />

09923518 . . . . . . . . . . . . . . . . . . . . . . . . . . 137<br />

09926070 . . . . . . . . . . . . . . . . . . . . . . . . . . 228<br />

09926083 . . . . . . . . . . . . . . . . . . . . . . . . . . . 18<br />

09934472 . . . . . . . . . . . . . . . . . . . . . . . . . . 137<br />

09934562 . . . . . . . . . . . . . . . . . . . . . . . . . . 137<br />

09935404 . . . . . . . . . . . . . . . . . . . . . . . . . . 144<br />

09936189 . . . . . . . . . . . . . . . . . . . . . . . . . . 316<br />

09936341 . . . . . . . . . . . . . . . . . . . . . . . . . . 137<br />

09936504 . . . . . . . . . . . . . . . . . . . . . . . . . . 316<br />

09936751 . . . . . . . . . . . . . . . . . . . . . . . . . . 315<br />

09937138 . . . . . . . . . . . . . . . . . . . . . . . . . . 375<br />

09937169 . . . . . . . . . . . . . . . . . . . . . . . . . . 321<br />

09938727 . . . . . . . . . . . . . . . . . . . . . . . . . . 314<br />

09938906 . . . . . . . . . . . . . . . . . . . . . . . . . . 315<br />

09938910 . . . . . . . . . . . . . . . . . . . . . . . . . . 321<br />

09938912 . . . . . . . . . . . . . . . . . . . . . . . . . . 273<br />

09938914 . . . . . . . . . . . . . . . . . . . . . . . . . . 314<br />

09940438 . . . . . . . . . . . . . . . . . . . . . . 229-230<br />

09972321 . . . . . . . . . . . . . . . . . . . . . . . . . . 135<br />

09972337 . . . . . . . . . . . . . . . . . . . . . . . . . . 315<br />

09981785 . . . . . . . . . . . . . . . . . . . . . . . . . . 369<br />

09985514 . . . . . . . . . . . . . . . . . . . . . . . . . . 230<br />

09985708 . . . . . . . . . . . . . . . 18, 167, 223-224<br />

09985727 . . . . . . . . . . . . . . . . . . . . . . . . . . 230<br />

Part No. Page Part No. Page Part No. Page<br />

See page 4 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

See page 2 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong>


Index Part Number 09985729 – B0157117<br />

Index<br />

Part Number<br />

410<br />

09985729 . . . . . . . . . . . . . . . . . . . . . . 226, 230<br />

09986072 . . . . . . . . . . . . . . . . . . . . . . . . . . 226<br />

09988015 . . . . . . . . . . . . . . . . . . . . . . . . . . 368<br />

09988017 . . . . . . . . . . . . . . . . . . . . . . . . . . 368<br />

09989859 . . . . . . . . . . . . . . . . . . . . . . . . . . 219<br />

09991413 . . . . . . . . . . . . . . . . . . . . . . 175, 330<br />

09991414 . . . . . . . . . . . . . . . . . . . . . . 175, 330<br />

09991415 . . . . . . . . . . . . . . . . . . . . . . 175, 330<br />

09991416 . . . . . . . . . . . . . . . . . . . . . . 175, 330<br />

09991417 . . . . . . . . . . . . . . . . . . . . . . 175, 330<br />

09991463 . . . . . . . . . . . . . . . . . . . . . . . . . . 137<br />

09992731 . . . . . . . . . . . . . . . . . . . . . . . . . . 219<br />

09995097 . . . . . . . . . . . . . . . . . . . . . . . . . . . 37<br />

09995098 . . . . . . . . . . . . . . . . . . . . . . . . . . 216<br />

09997196 . . . . . . . . . . . . . . . . . . . . . . . . . . 331<br />

10070900 . . . . . . . . . . . . . . . . . . . . . . . . . . 325<br />

10071000 . . . . . . . . . . . . . . . . . . . . . . . . . . 325<br />

10082600 . . . . . . . . . . . . . . . . . . . . . . . . . . 326<br />

20143300 . . . . . . . . . . . . . . . . . . . . . . . . . . 326<br />

25000323 . . . . . . . . . . . . . . . . . . . . . . . . . . 316<br />

26000050 . . . . . . . . . . . . . . . . . . . . . . . . . . 316<br />

29000078 . . . . . . . . . . . . . . . . . . . . . . . . . . 316<br />

29000544 . . . . . . . . . . . . . . . . . . . . . . . . . . 316<br />

29000545 . . . . . . . . . . . . . . . . . . . . . . . . . . 316<br />

41000013 . . . . . . . . . . . . . . . . . . . . . . . . . . 326<br />

51000634 . . . . . . . . . . . . . . . . . . . . . . . . . . 245<br />

51000635 . . . . . . . . . . . . . . . . . . . . . . . . . . 245<br />

51000636 . . . . . . . . . . . . . . . . . . . . . . . . . . 245<br />

51000637 . . . . . . . . . . . . . . . . . . . . . . . . . . 245<br />

51000638 . . . . . . . . . . . . . . . . . . . . . . . . . . 245<br />

51000639 . . . . . . . . . . . . . . . . . . . . . . . . . . 245<br />

51001135 . . . . . . . . . . . . . . . . . . . . . . . . . . 248<br />

51001137 . . . . . . . . . . . . . . . . . . . . . . . . . . 248<br />

51001140 . . . . . . . . . . . . . . . . . . . . . . . . . . 248<br />

51001141 . . . . . . . . . . . . . . . . . . . . . . . . . . 248<br />

51001144 . . . . . . . . . . . . . . . . . . . . . . . . . . 258<br />

51001148 . . . . . . . . . . . . . . . . . . . . . . . . . . 258<br />

51001149 . . . . . . . . . . . . . . . . . . . . . . . . . . 258<br />

51001152 . . . . . . . . . . . . . . . . . . . . . . . . . . 258<br />

51001188 . . . . . . . . . . . . . . . . . . . . . . . . . . 248<br />

51001324 . . . . . . . . . . . . . . . . . . . . . . . . . . 248<br />

51001325 . . . . . . . . . . . . . . . . . . . . . . . . . . 248<br />

51001326 . . . . . . . . . . . . . . . . . . . . . . . . . . 248<br />

51001327 . . . . . . . . . . . . . . . . . . . . . . . . . . 248<br />

51001328 . . . . . . . . . . . . . . . . . . . . . . . . . . 248<br />

51001329 . . . . . . . . . . . . . . . . . . . . . . . . . . 248<br />

51002592 . . . . . . . . . . . . . . . . . . . . . . . . . . 259<br />

51002593 . . . . . . . . . . . . . . . . . . . . . . . . . . 259<br />

51004599 . . . . . . . . . . . . . . . . . . . . . . . . . . 258<br />

51010817 . . . . . . . . . . . . . . . . . . . . . . . . . . 245<br />

51012725 . . . . . . . . . . . . . . . . . . . . . . . . . . 245<br />

52001539 . . . . . . . . . . . . . . . . . . . . . . . . . . 249<br />

52001543 . . . . . . . . . . . . . . . . . . . . . . . . . . 249<br />

54019985 . . . . . . . . . . . . . . . . . . . . . . . . . . 159<br />

60000186 . . . . . . . . . . . . . . . . . . . . . . . . . . 316<br />

60000366 . . . . . . . . . . . . . . . . . . . . . . . . . . 316<br />

65105001 . . . . . . . . . . . . . . . . . . . . . . 177, 331<br />

65105102 . . . . . . . . . . . . . . . . . . . . . . 177, 331<br />

65105204 . . . . . . . . . . . . . . . . . . . . . . 177, 331<br />

65105408 . . . . . . . . . . . . . . . . . . . . . . 177, 331<br />

65204501 . . . . . . . . . . . . . . . . . . . . . . . . . . 177<br />

65605810 . . . . . . . . . . . . . . . . . . . . . . . . . . 177<br />

65607610 . . . . . . . . . . . . . . . . . . . . . . . . . . 177<br />

65607625 . . . . . . . . . . . . . . . . . . . . . . . . . . 177<br />

65609010 . . . . . . . . . . . . . . . . . . . . . . . . . . 177<br />

65609025 . . . . . . . . . . . . . . . . . . . . . . . . . . 177<br />

72000008 . . . . . . . . . . . . . . . . . . . . . . . . . . 316<br />

B0008754 . . . . . . . . . . . . . . . . . . . . . . . . . . 400<br />

B0017041 . . . . . . . . . . . . . . . . . . . . . . . . . . 399<br />

B0017047 . . . . . . . . . . . . . . . . . . . . . . . . . . 399<br />

B0017052 . . . . . . . . . . . . . . . . . . . . . . . . . . 399<br />

B0017054 . . . . . . . . . . . . . . . . . . . . . . . . . . 399<br />

B0017057 . . . . . . . . . . . . . . . . . . . . . . . . . . 399<br />

B0017059 . . . . . . . . . . . . . . . . . . . . . . . . . . 400<br />

B0017072 . . . . . . . . . . . . . . . . . . . . . . . . . . 399<br />

B0017998 . . . . . . . . . . . . . . . . . . . . . 10, 12, 25<br />

B0018283 . . . . . . . . . . . . . . . . . 22, 25-26, 226<br />

B0022087 . . . . . . . . . . . . . . . . . . . . . . . . . . 399<br />

B0022088 . . . . . . . . . . . . . . . . . . . . . . . . . . 399<br />

B0023363 . . . . . . . . . . . . . . . . . . . . . . . . . . 399<br />

B0023365 . . . . . . . . . . . . . . . . . . . . . . . . . . 399<br />

B0023491 . . . . . . . . . . . . . . . . . . . . . . . . . . 400<br />

B0023492 . . . . . . . . . . . . . . . . . . . . . . . . . . 400<br />

B0029792 . . . . . . . . . . . . . . . . . 10, 12, 25, 224<br />

B0029796 . . . . . . . . . . . . . . . . . . . . . . . . . . . 27<br />

B0041693 . . . . . . . . . . . . . . . . . . . . . . . . . . 399<br />

B0041695 . . . . . . . . . . . . . . . . . . . . . . . . . . 400<br />

B0041696 . . . . . . . . . . . . . . . . . . . . . . . . . . 399<br />

B0045095 . . . . . . . . . . . . . . . . . . . . . . . . . . . 20<br />

B0045472 . . . . . . . . . . . . . . . . . . . . . . . . . . . 25<br />

B0046948 . . . . . . . . . . . . . . . . . . . . . . . . . . . 22<br />

B0047209 . . . . . . . . . . . . . . . . . . . . . . . . . . . 33<br />

B0048139 . . . . . . . . . . . . . . . . . . . . . . . . . 8, 25<br />

B0055900 . . . . . . . . . . . . . . . . . . . . . . . . . . . 11<br />

B0057334 . . . . . . . . . . . . . . . . . . . . . . . . . . . 20<br />

B0057336 . . . . . . . . . . . . . . . . . . . . . . . . . . . 20<br />

B0057408 . . . . . . . . . . . . . . . . . . . . . . . . . . . 20<br />

B0057409 . . . . . . . . . . . . . . . . . . . . . . . . . . . 20<br />

B0057410 . . . . . . . . . . . . . . . . . . . . . . . . . . . 20<br />

B0057761 . . . . . . . . . . . . . . . . . . . . . . . . . . . 20<br />

B0062666 . . . . . . . . . . . . . . . . . . . . . . . . . . 400<br />

B0066549 . . . . . . . . . . . . . . . . 22, 33, 219, 349<br />

B0070126 . . . . . . . . . . . . . . . . . . . . . . . . . . . 26<br />

B0070699 . . . . . . . . . . . . . . . . . . . . . . . . . . . 32<br />

B0071145 . . . . . . . . . . . . . . . . . . . . . . . . . . . 33<br />

B0071519 . . . . . . . . . . . . . . . . . . . . . . . . . . 384<br />

B0076786 . . . . . . . . . . . . . . . . . . . . . . . . . . 400<br />

B0080112 . . . . . . . . . . . . . . . . . . . . . . . . . . . 31<br />

B0080171 . . . . . . . . . . . . . . . . . . . . . . . . . . 386<br />

B0080259 . . . . . . . . . . . . . . . . . . . . . . . . . . . 32<br />

B0080333 . . . . . . . . . . . . . . . . . . . . . . . . . . . 10<br />

B0080819 . . . . . . . . . . . . . . . . . . . . . . . . . . 386<br />

B0080821 . . . . . . . . . . . . . . . . . . . . . . . . . . 388<br />

B0080822 . . . . . . . . . . . . . . . . . . . . . . . . . . 389<br />

B0080850 . . . . . . . . . . . . . . . . . . . . . . . . . . . 33<br />

B0082539 . . . . . . . . . . . . . . . . . . . . . . . . . . 388<br />

B0084183 . . . . . . . . . . . . . . . . . . . . . . . . . . 383<br />

B0086142 . . . . . . . . . . . . . . . . . . . . . . . . . . . 12<br />

B0086703 . . . . . . . . . . . . . . . . . . . . . . . . . . 384<br />

B0087056 . . . . . . . . . . . . . . . . . . . . . . . . . . . 11<br />

B0087354 . . . . . . . . . . . . . . . . . . . . . . . . . . . 49<br />

B0087600 . . . . . . . . . . . . . . . . . . . . . . . . . . . 11<br />

B0089439 . . . . . . . . . . . . . . . . . . . . . . . . . . 389<br />

B0091504 . . . . . . . . . . . . . . . . . . . . . . . 32, 193<br />

B0091906 . . . . . . . . . . . . . . . . . . . . . . . . . . 397<br />

B0092456 . . . . . . . . . . . . . . . . . . . . . . . . . . 273<br />

B0092468 . . . . . . . . . . . . . . . . . . . . . . . . . . 273<br />

B0094032 . . . . . . . . . . . . . . . . . . . . . . . . . . . 49<br />

B0094138 . . . . . . . . . . . . . . . . . . . . . . . . . . . 49<br />

B0094140 . . . . . . . . . . . . . . . . . . . . . . . . . . . 49<br />

B0094321 . . . . . . . . . . . . . . . . . . . . . . . . . . . 49<br />

B0094404 . . . . . . . . . . . . . . . . . . . . . . . . . . 400<br />

B0094413 . . . . . . . . . . . . . . . . . . . . . . . . . . . 49<br />

B0094415 . . . . . . . . . . . . . . . . . . . . . . . . . . . 49<br />

B0097693 . . . . . . . . . . . . . . . . . . . . . . . . . . . 49<br />

B0097694 . . . . . . . . . . . . . . . . . . . . . . . . . . . 49<br />

B0098258 . . . . . . . . . . . . . . . . . . . . . . . . . . . 31<br />

B0098452 . . . . . . . . . . . . . . . . . . . . . . . . . . . 49<br />

B0098453 . . . . . . . . . . . . . . . . . . . . . . . . . . . 49<br />

B0098640 . . . . . . . . . . . . . . . . . . . . . . . . . . . 49<br />

B0098799 . . . . . . . . . . . . . . . . . . . . . . . . . . 400<br />

B0098800 . . . . . . . . . . . . . . . . . . . . . . . . . . 400<br />

B0101045 . . . . . . . . . . . . . . . . . . . . . . . . . . . 11<br />

B0101161 . . . . . . . . . . . . . . . . . . . . . . . . . . . 12<br />

B0101164 . . . . . . . . . . . . . . . . . . . . . . . . . . . 12<br />

B0102332 . . . . . . . . . . . . . . . . . . . . . . . . . . . 12<br />

B0102949 . . . . . . . . . . . . . . . . . . . . . . . . . . . 15<br />

B0103037 . . . . . . . . . . . . . . . . . . . . . . . . . . . 12<br />

B0104236 . . . . . . . . . . . . . . . . . . . . . . . . . . 148<br />

B0104239 . . . . . . . . . . . . . . . . . . . . . . . . . . 148<br />

B0104240 . . . . . . . . . . . . . . . . . . . . . . . . . . 148<br />

B0104241 . . . . . . . . . . . . . . . . . . . . . . . . . . 148<br />

B0104242 . . . . . . . . . . . . . . . . . . . . . . . . . . 148<br />

B0104243 . . . . . . . . . . . . . . . . . . . . . . . . . . 148<br />

B0104244 . . . . . . . . . . . . . . . . . . . . . . . . . . 148<br />

B0104281 . . . . . . . . . . . . . . . . . . . . . . . . . . . 12<br />

B0104342 . . . . . . . . . . . . . . . . . . . . . . . . . . . 33<br />

B0104987 . . . . . . . . . . . . . . . . . . . . . . . . . . . 12<br />

B0105111 . . . . . . . . . . . . . . . . . . . . . . . . . . 193<br />

B0105197 . . . . . . . . . . . . . . . . . . . . . . . . . . . 32<br />

B0105973 . . . . . . . . . . . . . . . . . . . . . . . 11, 273<br />

B0105974 . . . . . . . . . . . . . . . . . . . . . . . 11, 273<br />

B0107592 . . . . . . . . . . . . . . . . . . . . . . . . . . 399<br />

B0107593 . . . . . . . . . . . . . . . . . . . . . . . . . . 399<br />

B0109322 . . . . . . . . . . . . . . . . . . . . . . . . . . . 32<br />

B0109324 . . . . . . . . . . . . . . . . . . . . . . . . . . . 31<br />

B0109944 . . . . . . . . . . . . . . . . . . . . . . . . . . 383<br />

B0114620 . . . . . . . . . . . . . . . . . . . . . . . . . . 397<br />

B0115576 . . . . . . . . . . . . . . . . . . . . . . . . . . . 33<br />

B0116823 . . . . . . . . . . . . . . . . . . . . . . . . . . . 31<br />

B0119079 . . . . . . . . . . . . . . . . . . . . . . . . . . . 11<br />

B0120242 . . . . . . . . . . . . . . . . . . . . . . . . . . . 31<br />

B0121084 . . . . . . . . . . . . . . . . . . . . . . . . . . 273<br />

B0127014 . . . . . . . . . . . . . . . . . . . . . . . . . . . 45<br />

B0127431 . . . . . . . . . . . . . . . . . . . . . . . . . . . 31<br />

B0128495 . . . . . . . . . . . . . . . . . . . . . . . . . . . 31<br />

B0129258 . . . . . . . . . . . . . . . . . . . . . . . . . . . 12<br />

B0129303 . . . . . . . . . . . . . . . . . . . . . . . . . . . 11<br />

B0129926 . . . . . . . . . . . . . . . . . . . . . . . . . . . 15<br />

B0131186 . . . . . . . . . . . . . . . . . . . . . . . . . . 399<br />

B0131385 . . . . . . . . . . . . . . . . . . . . . . . . . . 147<br />

B0131410 . . . . . . . . . . . . . . . . . . . . . . . . . . 145<br />

B0132799 . . . . . . . . . . . . . . . . . . . . . . . . . . . 12<br />

B0133956 . . . . . . . . . . . . . . . . . . . . . . . . . . 273<br />

B0135485 . . . . . . . . . . . . . . . . . . . . . . . . . . 145<br />

B0135653 . . . . . . . . . . . . . . . . . . . . . . . 32, 193<br />

B0137111 . . . . . . . . . . . . . . . . . . . . . . . . . . . 32<br />

B0137112 . . . . . . . . . . . . . . . . . . . . . . . . . . . 31<br />

B0139005 . . . . . . . . . . . . . . . . . . . . . . . . . . 344<br />

B0139120 . . . . . . . . . . . . . . . . . . . . . . . . . . 345<br />

B0139122 . . . . . . . . . . . . . . . . . . . . . . . . . . 345<br />

B0139997 . . . . . . . . . . . . . . . . . . . . . . . . . . 193<br />

B0142511 . . . . . . . . . . . . . . . . . . . . . . . . . . 345<br />

B0142512 . . . . . . . . . . . . . . . . . . . . . . . . . . 345<br />

B0143003 . . . . . . . . . . . . . . . . . . . . . . 338-339<br />

B0143015 . . . . . . . . . . . . . . . . . . . . . . 338-339<br />

B0143016 . . . . . . . . . . . . . . . . . . . . . . 338-339<br />

B0143017 . . . . . . . . . . . . . . . . . . . . . . 338-339<br />

B0143018 . . . . . . . . . . . . . . . . . . . . . . . . . . 338<br />

B0143019 . . . . . . . . . . . . . . . . . . . . . . . . . . 338<br />

B0143263 . . . . . . . . . . . . . . . . . . . . . . . . . . 345<br />

B0144169 . . . . . . . . . . . . . . . . . . . . . . . . . . 147<br />

B0147449 . . . . . . . . . . . . . . . . . . . . . . . . . . 145<br />

B0148615 . . . . . . . . . . . . . . . . . . . . . . . . . . . 45<br />

B0148651 . . . . . . . . . . . . . . . . . . . . . . . . . . . 20<br />

B0151573 . . . . . . . . . . . . . . . . . . . . . . . . . . . 15<br />

B0151579 . . . . . . . . . . . . . . . . . . . . . . . . . . . 15<br />

B0151697 . . . . . . . . . . . . . . . . . . . . . . . . . . . 15<br />

B0151737 . . . . . . . . . . . . . . . . . . . . . . . . . . 145<br />

B0152456 . . . . . . . . . . . . . . . . . . . . . . . . . . . 20<br />

B0152471 . . . . . . . . . . . . . . . . . . . . . . . . . . 389<br />

B0153250 . . . . . . . . . . . . . . . . . . . . . . . . . . . 15<br />

B0155481 . . . . . . . . . . . . . . . . . . . . . . . . . . 193<br />

B0155546 . . . . . . . . . . . . . . . . . . . . . . . . . . . 15<br />

B0156094 . . . . . . . . . . . . . . . . . . . . . . . . . . . 44<br />

B0157117 . . . . . . . . . . . . . . . . . . . . . . . . . . . 15<br />

Part No. Page Part No. Page Part No. Page


B0158598 – B0509561 Part Number Index<br />

Index<br />

Part Number<br />

411<br />

B0158598 . . . . . . . . . . . . . . . . . . . . . . . . . . . 15<br />

B0158616 . . . . . . . . . . . . . . . . . . . . . . . . . . . 15<br />

B0158690 . . . . . . . . . . . . . . . . . . . . . . . . . . . 15<br />

B0159356 . . . . . . . . . . . . . . . . . . . . . . . . . . 148<br />

B0159357 . . . . . . . . . . . . . . . . . . . . . . . . . . 148<br />

B0160697 . . . . . . . . . . . . . . . . . . . . . . . . . . . 15<br />

B0160917 . . . . . . . . . . . . . . . . . . . . . . . . . . 397<br />

B0162668 . . . . . . . . . . . . . . . . . . . . . . . . . . . 15<br />

B0162669 . . . . . . . . . . . . . . . . . . . . . . . . . . . 15<br />

B0162671 . . . . . . . . . . . . . . . . . . . . . . . . . . . 15<br />

B0162836 . . . . . . . . . . . . . . . . . . . . . . . . . . 273<br />

B0165332 . . . . . . . . . . . . . . . . . . . . . . . . . . . 19<br />

B0166502 . . . . . . . . . . . . . . . . . . . . . . . . . . . 20<br />

B0166503 . . . . . . . . . . . . . . . . . . . . . . . . . . . 17<br />

B0166505 . . . . . . . . . . . . . . . . . . . . . . . . . . . 20<br />

B0166506 . . . . . . . . . . . . . . . . . . . . . . . . . . . 20<br />

B0166507 . . . . . . . . . . . . . . . . . . . . . . . . . . . 20<br />

B0169319 . . . . . . . . . . . . . . . . . . . . . . 338-339<br />

B0169320 . . . . . . . . . . . . . . . . . . . . . . 338-339<br />

B0169321 . . . . . . . . . . . . . . . . . . . . . . 338-339<br />

B0170873 . . . . . . . . . . . . . . . . . . . . . . . . . . 273<br />

B0170875 . . . . . . . . . . . . . . . . . . . . . . . . . . 273<br />

B0173404 . . . . . . . . . . . . . . . . . . . . . . . . . . . 15<br />

B0174378 . . . . . . . . . . . . . . . . . . . . . 15, 18-19<br />

B0174379 . . . . . . . . . . . . . . . . . . . . . . . . . . . 15<br />

B0174380 . . . . . . . . . . . . . . . . . . . . . . . . . . . 15<br />

B0180361 . . . . . . . . . . . . . . . . . . . . . . . . . . . 31<br />

B0180363 . . . . . . . . . . . . . . . . . . . . . . . . . . . 31<br />

B0181091 . . . . . . . . . . . . . . . . . . . . . . . . . . 341<br />

B0181354 . . . . . . . . . . . . . . . . . . . . . . . . . . . 25<br />

B0181576 . . . . . . . . . . . . . . . . . . . . . . . . . . 349<br />

B0181842 . . . . . . . . . . . . . . . . . . . . . . . . . . . 15<br />

B0182864 . . . . . . . . . . . . . . . . . . . . . . . . . . 344<br />

B0182901 . . . . . . . . . . . . . . . . . . . . . . . . . . 340<br />

B0182902 . . . . . . . . . . . . . . . . . . . . . . . . . . 340<br />

B0182903 . . . . . . . . . . . . . . . . . . . . . . . . . . 340<br />

B0182981 . . . . . . . . . . . . . . . . . . . . . . . . . . 345<br />

B0184142 . . . . . . . . . . . . . . . . . . . . . . . . . . 143<br />

B0185163 . . . . . . . . . . . . . . . . . . . . . . . . . . 389<br />

B0185210 . . . . . . . . . . . . . . . . . . . . . . . . . . 387<br />

B0185227 . . . . . . . . . . . . . . . . . . . . . . . . . . 386<br />

B0185259 . . . . . . . . . . . . . . . . . . . . . . . . . . 273<br />

B0185480 . . . . . . . . . . . . . . . . . . . . . . . . . . 273<br />

B0186924 . . . . . . . . . . . . . . . . . . . . . . . . . . 349<br />

B0187028 . . . . . . . . . . . . . . . . . . . . . . . . . . 386<br />

B0187258 . . . . . . . . . . . . . . . . . . . . . . . . . . . 22<br />

B0190001 . . . . . . . . . . . . . . . . . . . . . . . . . . . 15<br />

B0190634 . . . . . . . . . . . . . . . . . . . . . 32, 35, 67<br />

B0190635 . . . . . . . . . . . . . . . . . . . . . 32, 35, 67<br />

B0190672 . . . . . . . . . . . . . . . . . . . . . . . . 15, 19<br />

B0191058 . . . . . . . . . . . . . . . . . . . . . 23, 25, 28<br />

B0191059 . . . . . . . . . . . . . . . . . . . . . 23, 25, 28<br />

B0191060 . . . . . . . . . . . . . . . . . . . . . . . . . 9, 25<br />

B0191090 . . . . . . . . . . . . . . . . . . . . . . . . . . . 26<br />

B0191766 . . . . . . . . . . . . . . . . . . . . . . . . . . 383<br />

B0193160 . . . . . . . . . . . . . . . . . . . . . . . . 23, 25<br />

B0193161 . . . . . . . . . . . . . . . . . . . . . . . . 25, 28<br />

B0193233 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8<br />

B0193234 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8<br />

B0193235 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8<br />

B0193342 . . . . . . . . . . . . . . . . . . . . . 23-24, 28<br />

B0193766 . . . . . . . . . . . . . . . . . . . . . . . . . . 273<br />

B0193768 . . . . . . . . . . . . . . . . . . . . . . . . . . 389<br />

B0193772 . . . . . . . . . . . . . . . . . . . . . . . . . . . 22<br />

B0193780 . . . . . . . . . . . . . . . . . . . . . . . . . . 273<br />

B0193793 . . . . . . . . . . . . . . . . . . . . . . . . . . . 26<br />

B0193873 . . . . . . . . . . . . . . . . . . . . . . . . . . . 24<br />

B0194048 . . . . . . . . . . . . . . . . . . . . . . . . . . . 25<br />

B0194049 . . . . . . . . . . . . . . . . . . . . . . . . . . . 25<br />

B0196704 . . . . . . . . . . . . . . . . . . . . . . . . 24, 28<br />

B0196850 . . . . . . . . . . . . . . . . . . . . . . . . 24, 28<br />

B0196857 . . . . . . . . . . . . . . . . . . . . . . . . . . . 24<br />

B0196858 . . . . . . . . . . . . . . . . . . . . . . 341, 349<br />

B0196882 . . . . . . . . . . . . . . . . . . . . . . . . . . . 24<br />

B0196912 . . . . . . . . . . . . . . . . . . . . . . . . . . 380<br />

B0197336 . . . . . . . . . . . . . . . . . . . . . . . . . . 145<br />

B0198005 . . . . . . . . . . . . . . . . . . . . . . . . . . . 35<br />

B0198016 . . . . . . . . . . . . . . . . . . . . . . . . . . 273<br />

B0198017 . . . . . . . . . . . . . . . . . . . . . . . . . . 273<br />

B0198023 . . . . . . . . . . . . . . . . . . . . . . . . . . 383<br />

B0198030 . . . . . . . . . . . . . . . . . . . . . . 341, 349<br />

B0198072 . . . . . . . . . . . . . . . . . . . . . . . . . . . 35<br />

B0198093 . . . . . . . . . . . . . . . . . . . . . . . . . . . 80<br />

B0198097 . . . . . . . . . . . . . . . . . . . . . . . . 23, 25<br />

B0198099 . . . . . . . . . . . . . . . . . . . . . . . . 25-26<br />

B0198100 . . . . . . . . . . . . . . . . . . . . . . . . 25-26<br />

B0198104 . . . . . . . . . . . . . . . . . . . . . . . . . . . 26<br />

B0198110 . . . . . . . . . . . . . . . . . . . . . . . . . . 147<br />

B0198111 . . . . . . . . . . . . . . . . . . . . . . . . 23, 26<br />

B0198180 . . . . . . . . . . . . . . . . . . . . . . . . . . 273<br />

B0198201 . . . . . . . . . . . . . . . . . . . . . . . . 24, 26<br />

B0199034 . . . . . . . . . . . . . . . . . . . . . . . 25, 383<br />

B0199035 . . . . . . . . . . . . . . . . . . . . . . . . . . . 24<br />

B0199233 . . . . . . . . . . . . . . . . . . . . . . . . . . . 24<br />

B0199379 . . . . . . . . . . . . . . . . . . . . . . . . . . 346<br />

B0500695 . . . . . . . . . . . . . . . . . . . . . . . . . . . 28<br />

B0500722 . . . . . . . . . . . . . . . . . . . . . . . . . . 346<br />

B0500724 . . . . . . . . . . . . . . . . . . . . . . . . . . 346<br />

B0500748 . . . . . . . . . . . . . . . . . . . . . . . . . . . 34<br />

B0500778 . . . . . . . . . . . . . . . . . . . . . . . . . . 144<br />

B0500833 . . . . . . . . . . . . . . . . . . . . . . . . . . 147<br />

B0500843 . . . . . . . . . . . . . . . . . . . . . . . . . . 145<br />

B0500952 . . . . . . . . . . . . . . . . . . . . . . . . . . 389<br />

B0500959 . . . . . . . . . . . . . . . . . . . . . . . . . . 147<br />

B0500987 . . . . . . . . . . . . . . . . . . . . . . . . . . 147<br />

B0501000 . . . . . . . . . . . . . . . . . . . . . . . . 25-26<br />

B0501022 . . . . . . . . . . . . . . . . . . . . . . . . . . . 17<br />

B0501025 . . . . . . . . . . . . . . . . . . . . . . . . . . . 17<br />

B0501026 . . . . . . . . . . . . . . . . . . . . . . . . . . . 17<br />

B0501029 . . . . . . . . . . . . . . . . . . . . . . . . . . . 17<br />

B0501056 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8<br />

B0501236 . . . . . . . . . . . . . . . . . . . . . . . . . . . 35<br />

B0501252 . . . . . . . . . . . . . . . . . . . . . . . . . . . 37<br />

B0501258 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8<br />

B0501282 . . . . . . . . . . . . . . . . . . . . . . . . . . 382<br />

B0501315 . . . . . . . . . . . . . . . . . . . . . . . . . . . 24<br />

B0501580 . . . . . . . . . . . . . . . . . . . . . . . . 24, 28<br />

B0501594 . . . . . . . . . . . . . . . . . . . . . . . . 25, 28<br />

B0501595 . . . . . . . . . . . . . . . . . . . . . . . . 25, 28<br />

B0501696 . . . . . . . . . . . . . . . . . . . . . . . . . . . 37<br />

B0502195 . . . . . . . . . . . . . . . . . . . . . . . . . . . 55<br />

B0502196 . . . . . . . . . . . . . . . . . . . . . . . . . . . 55<br />

B0502197 . . . . . . . . . . . . . . . . . . . . . . . . 53, 55<br />

B0502201 . . . . . . . . . . . . . . . . . . . . . . . . . . . 54<br />

B0502202 . . . . . . . . . . . . . . . . . . . . . . . . . . . 54<br />

B0502203 . . . . . . . . . . . . . . . . . . . . . . . . . . . 54<br />

B0502204 . . . . . . . . . . . . . . . . . . . . . . . . . . . 54<br />

B0502706 . . . . . . . . . . . . . . . . . . . . . . . . 26, 37<br />

B0502921 . . . . . . . . . . . . . . . . . . . . . . . . . . . 25<br />

B0502923 . . . . . . . . . . . . . . . . . . . . . . . . . . . 25<br />

B0502924 . . . . . . . . . . . . . . . . . . . . . . . . . . . 25<br />

B0502925 . . . . . . . . . . . . . . . . . . . . . . . . . . . 25<br />

B0503956 . . . . . . . . . . . . . . . . . . . . . . . . . . 147<br />

B0504033 . . . . . . . . . . . . . . . . . . . . . . . . . . . 34<br />

B0504035 . . . . . . . . . . . . . . . . . . . . . . . . . . . 34<br />

B0504036 . . . . . . . . . . . . . . . . . . . . . . . . . . . 34<br />

B0504047 . . . . . . . . . . . . . . . . . . . . . . . 28, 188<br />

B0504048 . . . . . . . . . . . . . . . . . . . . . . . 28, 188<br />

B0505071 . . . . . . . . . . . . . . . . . . . . . . . . . . 388<br />

B0505086 . . . . . . . . . . . . . . . . . . . . . . . . 17-19<br />

B0505266 . . . . . . . . . . . . . . . . . . . . . . . . . . 146<br />

B0505268 . . . . . . . . . . . . . . . . . . . . . . . . . . 145<br />

B0505271 . . . . . . . . . . . . . . . . . . . . . . . . . . 144<br />

B0505284 . . . . . . . . . . . . . . . . . . . . . . . . . . 382<br />

B0505326 . . . . . . . . . . . . . . . . . . . . . . . . . . . 26<br />

B0505475 . . . . . . . . . . . . . . . . . . . . . . . . . . 143<br />

B0505480 . . . . . . . . . . . . . . . . . . . . . . . . 17, 19<br />

B0505530 . . . . . . . . . . . . . . . . . . . . . . . . . . 382<br />

B0505540 . . . . . . . . . . . . . . . . . . . . . . . . . . 188<br />

B0505588 . . . . . . . . . . . . . . . . . . . . . . . . . . . 17<br />

B0505589 . . . . . . . . . . . . . . . . . . . . . . . . . . . 17<br />

B0505590 . . . . . . . . . . . . . . . . . . . . . . . . 17, 19<br />

B0505601 . . . . . . . . . . . . . . . . . . . . . . . . . . 148<br />

B0505650 . . . . . . . . . . . . . . . . . . . . . . . . . . . 23<br />

B0505677 . . . . . . . . . . . . . . . . . . . . . . 270, 273<br />

B0505866 . . . . . . . . . . . . . . . . . . . . . . . . . . 383<br />

B0505889 . . . . . . . . . . . . . . . . . . . . . . . . . . 146<br />

B0505962 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9<br />

B0505978 . . . . . . . . . . . . . . . . . . . . . . . . . . 146<br />

B0506058 . . . . . . . . . . . . . . . . . . . . . . . . 25, 28<br />

B0506060 . . . . . . . . . . . . . . . . . . . . . . . . . . . 25<br />

B0506539 . . . . . . . . . . . . . . . . . . . . . . . . . . 146<br />

B0506592 . . . . . . . . . . . . . . . . . . . . . . . . . . 273<br />

B0506603 . . . . . . . . . . . . . . . . . . . . . . . . . . 146<br />

B0506666 . . . . . . . . . . . . . . . . . . . . . . . . . . . 17<br />

B0506668 . . . . . . . . . . . . . . . . . . . . . . . . . . . 17<br />

B0506716 . . . . . . . . . . . . . . . . . . . . . . . . . . . 24<br />

B0506722 . . . . . . . . . . . . . . . . . . . . . . . . . . . 35<br />

B0507020 . . . . . . . . . . . . . . . . . . . . . . . . . . . 25<br />

B0507021 . . . . . . . . . . . . . . . . . . . . . . . . . . . 25<br />

B0507226 . . . . . . . . . . . . . . . . . . . . . . . . . . . 67<br />

B0507355 . . . . . . . . . . . . . . . . . . . . . . . . . . 386<br />

B0507403 . . . . . . . . . . . . . . . . . . . . . . . . . . 399<br />

B0507447 . . . . . . . . . . . . . . . . . . . . . . . . . . 399<br />

B0507451 . . . . . . . . . . . . . . . . . . . . . . . . . . 399<br />

B0507486 . . . . . . . . . . . . . . . . . . . . . . . . . . . 22<br />

B0507487 . . . . . . . . . . . . . . . . . . . . . . . . . . . 22<br />

B0507692 . . . . . . . . . . . . . . . . . . . . . . . . 25, 28<br />

B0507708 . . . . . . . . . . . . . . . . . . . . . . . . . . . 25<br />

B0507777 . . . . . . . . . . . . . . . . . . . . . . . . . . . 26<br />

B0507779 . . . . . . . . . . . . . . . . . . . . . . . . . . . 26<br />

B0507791 . . . . . . . . . . . . . . . . . . . . . . . . . . . 23<br />

B0507792 . . . . . . . . . . . . . . . . . . . . . . . . . . . 23<br />

B0507805 . . . . . . . . . . . . . . . . . . . . . . . . . . 395<br />

B0507914 . . . . . . . . . . . . . . . . . . . . . . . . 23, 28<br />

B0507918 . . . . . . . . . . . . . . . . . . . . . . . . . . . 24<br />

B0507919 . . . . . . . . . . . . . . . . . . . . . . . . . 8, 24<br />

B0507920 . . . . . . . . . . . . . . . . . . . . . . . . . . . 24<br />

B0507921 . . . . . . . . . . . . . . . . . . . . . . . . . . . 24<br />

B0507942 . . . . . . . . . . . . . . . . . . . . . . . . . . 146<br />

B0507944 . . . . . . . . . . . . . . . . . . . . . . . . . . 146<br />

B0507949 . . . . . . . . . . . . . . . . . . . . . . . . . . . 24<br />

B0507957 . . . . . . . . . . . . . . . . . . . . . . . . 22-23<br />

B0507959 . . . . . . . . . . . . . . . . . . . . . . . . . . . 22<br />

B0507960 . . . . . . . . . . . . . . . . . . . . . . . . . . . 22<br />

B0507962 . . . . . . . . . . . . . . . . . . . . . . . . . . . 22<br />

B0508306 . . . . . . . . . . . . . . . . . . . . . . . . . . . 22<br />

B0508310 . . . . . . . . . . . . . . . . . . . . . . . . . . . 25<br />

B0508371 . . . . . . . . . . . . . . . . . . . . . . . . . . 193<br />

B0508373 . . . . . . . . . . . . . . . . . . . . . . . . . . 193<br />

B0508374 . . . . . . . . . . . . . . . . . . . . . . . . . . 193<br />

B0508520 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8<br />

B0508521 . . . . . . . . . . . . . . . . . . . . . . . . . . 146<br />

B0508593 . . . . . . . . . . . . . . . . . . . . . . . . . . 188<br />

B0508594 . . . . . . . . . . . . . . . . . . . . . . . . . . . 23<br />

B0508738 . . . . . . . . . . . . . . . . . . . . . . . . . . 146<br />

B0508836 . . . . . . . . . . . . . . . . . . . . . . . . . . . 35<br />

B0508901 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8<br />

B0508902 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8<br />

B0509065 . . . . . . . . . . . . . . . . . . . . . . . . . . . 37<br />

B0509095 . . . . . . . . . . . . . . . . . . . . . . . . 23, 28<br />

B0509479 . . . . . . . . . . . . . . . . . . . . . . . . . . . 22<br />

B0509546 . . . . . . . . . . . . . . . . . . . . . . . . . . 380<br />

B0509554 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8<br />

B0509555 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8<br />

B0509561 . . . . . . . . . . . . . . . . . . . . . . . . . . . 28<br />

Part No. Page Part No. Page Part No. Page<br />

See page 4 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

See page 2 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong>


Index Part Number B0509590 – B3001262<br />

Index<br />

Part Number<br />

412<br />

B0509590 . . . . . . . . . . . . . . . . . . . . . . . . 23, 28<br />

B0509591 . . . . . . . . . . . . . . . . . . . . . . . . . . 380<br />

B0509612 . . . . . . . . . . . . . . . . . . . . . . . . . . . 27<br />

B0509650 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8<br />

B0509652 . . . . . . . . . . . . . . . . . . . . . . . . . . . 10<br />

B0510032 . . . . . . . . . . . . . . . . . . . . . . . . . . . 27<br />

B0510070 . . . . . . . . . . . . . . . . . . . . . . . . . . 386<br />

B0510251 . . . . . . . . . . . . . . . . . . . . . . . . . . 146<br />

B0510364 . . . . . . . . . . . . . . . . . . . . . . . . . . 147<br />

B0510366 . . . . . . . . . . . . . . . . . . . . . . . . . . 385<br />

B0510370 . . . . . . . . . . . . . . . . . . . . . . . . . . . 22<br />

B0510397 . . . . . . . . . . . . . . . . . . . . . . . . . . . 11<br />

B0510398 . . . . . . . . . . . . . . . . . . . . . . . . . . . 11<br />

B0510403 . . . . . . . . . . . . . . . . . . . . . . . . . . 146<br />

B0510404 . . . . . . . . . . . . . . . . . . . . . . . . . . . 11<br />

B0510412 . . . . . . . . . . . . . . . . . . . . . . . . . . 385<br />

B0510417 . . . . . . . . . . . . . . . . . . . . . . . . . . . 11<br />

B0510487 . . . . . . . . . . . . . . . . . . . . . . . . . . . 22<br />

B0510581 . . . . . . . . . . . . . . . . . . . . . . . . . . 400<br />

B0510984 . . . . . . . . . . . . . . . . . . . . . . . . . . 145<br />

B0511502 . . . . . . . . . . . . . . . . . . . . . . . . . . . 51<br />

B0511503 . . . . . . . . . . . . . . . . . . . . . . . . . . . 51<br />

B0511504 . . . . . . . . . . . . . . . . . . . . . . . . . . . 51<br />

B0511505 . . . . . . . . . . . . . . . . . . . . . . . . . . . 51<br />

B0511506 . . . . . . . . . . . . . . . . . . . . . . . . . . . 52<br />

B0511507 . . . . . . . . . . . . . . . . . . . . . . . . . . . 52<br />

B0511511 . . . . . . . . . . . . . . . . . . . . . . . . . . . 52<br />

B0511512 . . . . . . . . . . . . . . . . . . . . . . . . . . . 52<br />

B0511513 . . . . . . . . . . . . . . . . . . . . . . . . . . . 51<br />

B0511514 . . . . . . . . . . . . . . . . . . . . . . . . . . . 51<br />

B0511515 . . . . . . . . . . . . . . . . . . . . . . . . . . . 51<br />

B0511516 . . . . . . . . . . . . . . . . . . . . . . . . . . . 51<br />

B0511517 . . . . . . . . . . . . . . . . . . . . . . . . . . . 51<br />

B0511518 . . . . . . . . . . . . . . . . . . . . . . . . . . . 51<br />

B0511519 . . . . . . . . . . . . . . . . . . . . . . . . . . . 51<br />

B0511522 . . . . . . . . . . . . . . . . . . . . . . . . . . . 51<br />

B0511523 . . . . . . . . . . . . . . . . . . . . . . . . . . . 51<br />

B0511524 . . . . . . . . . . . . . . . . . . . . . . . . . . . 51<br />

B0511525 . . . . . . . . . . . . . . . . . . . . . . . . . . . 51<br />

B0511526 . . . . . . . . . . . . . . . . . . . . . . . . . . . 51<br />

B0511527 . . . . . . . . . . . . . . . . . . . . . . . . . . . 51<br />

B0511528 . . . . . . . . . . . . . . . . . . . . . . . . . . . 52<br />

B0511529 . . . . . . . . . . . . . . . . . . . . . . . . . . . 52<br />

B0511530 . . . . . . . . . . . . . . . . . . . . . . . . . . . 52<br />

B0511532 . . . . . . . . . . . . . . . . . . . . . . . . . . . 54<br />

B0511533 . . . . . . . . . . . . . . . . . . . . . . . . . . . 54<br />

B0511534 . . . . . . . . . . . . . . . . . . . . . . . . . . . 54<br />

B0511535 . . . . . . . . . . . . . . . . . . . . . . . . . . . 54<br />

B0511537 . . . . . . . . . . . . . . . . . . . . . . . . . . . 55<br />

B0511538 . . . . . . . . . . . . . . . . . . . . . . . . . . . 54<br />

B0511539 . . . . . . . . . . . . . . . . . . . . . . . . . . . 54<br />

B0511540 . . . . . . . . . . . . . . . . . . . . . . . . . . . 55<br />

B0511541 . . . . . . . . . . . . . . . . . . . . . . . . 53, 55<br />

B0511546 . . . . . . . . . . . . . . . . . . . . . . . . . . . 55<br />

B0511601 . . . . . . . . . . . . . . . . . . . . . . . . . . . 51<br />

B0511602 . . . . . . . . . . . . . . . . . . . . . . . . . . . 51<br />

B0511603 . . . . . . . . . . . . . . . . . . . . . . . . . . . 51<br />

B0511674 . . . . . . . . . . . . . . . . . . . . . . . . . . . 54<br />

B0511675 . . . . . . . . . . . . . . . . . . . . . . . . . . . 54<br />

B0511676 . . . . . . . . . . . . . . . . . . . . . . . . . . . 54<br />

B0511677 . . . . . . . . . . . . . . . . . . . . . . . . 53, 55<br />

B0511678 . . . . . . . . . . . . . . . . . . . . . . . . . . . 54<br />

B0511679 . . . . . . . . . . . . . . . . . . . . . . . . . . . 55<br />

B0511778 . . . . . . . . . . . . . . . . . . . . . . . . . . . 37<br />

B0511779 . . . . . . . . . . . . . . . . . . . . . . . . . . . 37<br />

B0511806 . . . . . . . . . . . . . . . . . . . . . . . . . . . 37<br />

B0631001 . . . . . . . . . . . . . . . . . . . . . . . . . . 392<br />

B0631002 . . . . . . . . . . . . . . . . . . . . . . . . . . 392<br />

B0631003 . . . . . . . . . . . . . . . . . . . . . . . . . . 392<br />

B0631004 . . . . . . . . . . . . . . . . . . . . . . . . . . 392<br />

B0631005 . . . . . . . . . . . . . . . . . . . . . . . . . . 392<br />

B0631006 . . . . . . . . . . . . . . . . . . . . . . . . . . 392<br />

B0631007 . . . . . . . . . . . . . . . . . . . . . . . . . . 392<br />

B0631008 . . . . . . . . . . . . . . . . . . . . . . . . . . 392<br />

B0631009 . . . . . . . . . . . . . . . . . . . . . . . . . . 392<br />

B0631010 . . . . . . . . . . . . . . . . . . . . . . . . . . 392<br />

B0631011 . . . . . . . . . . . . . . . . . . . . . . . . . . 392<br />

B0631012 . . . . . . . . . . . . . . . . . . . . . . . . . . 392<br />

B0631013 . . . . . . . . . . . . . . . . . . . . . . 249, 392<br />

B0631014 . . . . . . . . . . . . . . . . . . . . . . 249, 392<br />

B0631015 . . . . . . . . . . . . . . . . . . . . . . 249, 392<br />

B0631016 . . . . . . . . . . . . . . . . . . . . . . 249, 392<br />

B0631017 . . . . . . . . . . . . . . . . . . . . . . 249, 392<br />

B0631018 . . . . . . . . . . . . . . . . . . . . . . 249, 392<br />

B0631019 . . . . . . . . . . . . . . . . . . . . . . . . . . 392<br />

B0631020 . . . . . . . . . . . . . . . . . . . . . . . . . . 392<br />

B0631021 . . . . . . . . . . . . . . . . . . . . . . . . . . 392<br />

B0631023 . . . . . . . . . . . . . . . . . . . . . . . . . . 392<br />

B0631025 . . . . . . . . . . . . . . . . . . . . . . . . . . 392<br />

B0631026 . . . . . . . . . . . . . . . . . . . . . . . . . . 392<br />

B0631027 . . . . . . . . . . . . . . . . . . . . . . . . . . 392<br />

B0631028 . . . . . . . . . . . . . . . . . . . . . . . . . . 392<br />

B0631029 . . . . . . . . . . . . . . . . . . . . . . . . . . 392<br />

B0631030 . . . . . . . . . . . . . . . . . . . . . . . . . . 392<br />

B0631031 . . . . . . . . . . . . . . . . . . . . . . 249, 392<br />

B0631032 . . . . . . . . . . . . . . . . . . . . . . 249, 392<br />

B0631033 . . . . . . . . . . . . . . . . . . . . . . 249, 392<br />

B0631034 . . . . . . . . . . . . . . . . . . . . . . 249, 392<br />

B0631035 . . . . . . . . . . . . . . . . . . . . . . 249, 392<br />

B0631036 . . . . . . . . . . . . . . . . . . . . . . 249, 392<br />

B0631039 . . . . . . . . . . . . . . . . . . . . . . . . . . 393<br />

B0631042 . . . . . . . . . . . . . . . . . . . . . . . . . . 393<br />

B0631045 . . . . . . . . . . . . . . . . . . . . . . 249, 393<br />

B0631046 . . . . . . . . . . . . . . . . . . . . . . . . . . 393<br />

B0631047 . . . . . . . . . . . . . . . . . . . . . . . . . . 393<br />

B0631048 . . . . . . . . . . . . . . . . . . . . . . . . . . 393<br />

B0631049 . . . . . . . . . . . . . . . . . . . . . . . . . . 393<br />

B0631050 . . . . . . . . . . . . . . . . . . . . . . . . . . 393<br />

B0631051 . . . . . . . . . . . . . . . . . . . . . . 249, 393<br />

B0631057 . . . . . . . . . . . . . . . . . . . . . . . . . . 394<br />

B0631060 . . . . . . . . . . . . . . . . . . . . . . 249, 394<br />

B0631061 . . . . . . . . . . . . . . . . . . . . . . . . . . 394<br />

B0631064 . . . . . . . . . . . . . . . . . . . . . . . . . . 394<br />

B0631065 . . . . . . . . . . . . . . . . . . . . . . 249, 394<br />

B0631066 . . . . . . . . . . . . . . . . . . . . . . 249, 394<br />

B0631070 . . . . . . . . . . . . . . . . . . . . . . . . . . 393<br />

B0631071 . . . . . . . . . . . . . . . . . . . . . . . . . . 393<br />

B0631076 . . . . . . . . . . . . . . . . . . . . . . . . . . 393<br />

B0631077 . . . . . . . . . . . . . . . . . . . . . . . . . . 393<br />

B0631078 . . . . . . . . . . . . . . . . . . . . . . 249, 393<br />

B0631079 . . . . . . . . . . . . . . . . . . . . . . . . . . 394<br />

B0631080 . . . . . . . . . . . . . . . . . . . . . . . . . . 394<br />

B0631081 . . . . . . . . . . . . . . . . . . . . . . . . . . 394<br />

B0631082 . . . . . . . . . . . . . . . . . . . . . . . . . . 394<br />

B0631083 . . . . . . . . . . . . . . . . . . . . . . . . . . 394<br />

B0631084 . . . . . . . . . . . . . . . . . . . . . . . . . . 391<br />

B0631085 . . . . . . . . . . . . . . . . . . . . . . . . . . 391<br />

B0631087 . . . . . . . . . . . . . . . . . . . . . . 383, 391<br />

B0631088 . . . . . . . . . . . . . . . . . . . . . . 383, 391<br />

B0631089 . . . . . . . . . . . . . . . . . . . . . . . . . . 391<br />

B0631090 . . . . . . . . . . . . . . . . . . . . . . . . . . 391<br />

B0631091 . . . . . . . . . . . . . . . . . . . . . . . . . . 391<br />

B0631092 . . . . . . . . . . . . . . . . . . . . . . . . . . 391<br />

B0631093 . . . . . . . . . . . . . . . . . . . . . . . . . . 391<br />

B0631094 . . . . . . . . . . . . . . . . . . . . . . . . . . 391<br />

B0631095 . . . . . . . . . . . . . . . . . . . . . . . . . . 391<br />

B0631096 . . . . . . . . . . . . . . . . . . . . . . . . . . 391<br />

B0631097 . . . . . . . . . . . . . . . . . . . . . . . . . . 391<br />

B0631098 . . . . . . . . . . . . . . . . . . . . . . . . . . 391<br />

B0631099 . . . . . . . . . . . . . . . . . . . . . . 249, 391<br />

B0631100 . . . . . . . . . . . . . . . . . . . . . . 249, 391<br />

B0631101 . . . . . . . . . . . . . . . . . . . . . . 249, 391<br />

B0631102 . . . . . . . . . . . . . . . . . . . . . . 249, 391<br />

B0631128 . . . . . . . . . . . . . . . . . . . . . . 249, 391<br />

B0631129 . . . . . . . . . . . . . . . . . . . . . . 249, 391<br />

B0631130 . . . . . . . . . . . . . . . . . . . . . . . . . . 391<br />

B0631131 . . . . . . . . . . . . . . . . . . . . . . . . . . 391<br />

B0631134 . . . . . . . . . . . . . . . . . . . . . . . . . . 392<br />

B0631144 . . . . . . . . . . . . . . . . . . . . . . . . . . 391<br />

B0631145 . . . . . . . . . . . . . . . . . . . . . . 249, 391<br />

B0631146 . . . . . . . . . . . . . . . . . . . . . . . . . . 391<br />

B0631147 . . . . . . . . . . . . . . . . . . . . . . . . . . 391<br />

B0631148 . . . . . . . . . . . . . . . . . . . . . . . . . . 391<br />

B0631149 . . . . . . . . . . . . . . . . . . . . . . 249, 391<br />

B0631150 . . . . . . . . . . . . . . . . . . . . . . . . . . 391<br />

B0631151 . . . . . . . . . . . . . . . . . . . . . . . . . . 391<br />

B0631152 . . . . . . . . . . . . . . . . . . . . . . . . . . 391<br />

B0810144 . . . . . . . . . . . . . . . . . . . . . . . . . . 216<br />

B0810377 . . . . . . . . . . . . . . . . . . . . . . . . . . 219<br />

B0851900 . . . . . . . . . . . . . . . . . . . . . . . . . . . 35<br />

B2000159 . . . . . . . . . . . . . . . . . . . . . . . . . . 385<br />

B2000160 . . . . . . . . . . . . . . . . . . . . . . . . . . 385<br />

B2000186 . . . . . . . . . . . . . . . . . . . . . . . . . . 387<br />

B2000199 . . . . . . . . . . . . . . . . . . . . . . . . . . 387<br />

B2000201 . . . . . . . . . . . . . . . . . . . . . . . . . . 389<br />

B2000310 . . . . . . . . . . . . . . . . . . . . . . . . . . 387<br />

B2100154 . . . . . . . . . . . . . . . . . . . . . . . . . . 400<br />

B2190036 . . . . . . . . . . . . . . . . . . . . . . . . . . 382<br />

B2190037 . . . . . . . . . . . . . . . . . . . . . . . . . . 383<br />

B2190038 . . . . . . . . . . . . . . . . . . . . . . . . . . 383<br />

B2205021 . . . . . . . . . . . . . . . . . . . . . . . . . . 382<br />

B2205022 . . . . . . . . . . . . . . . . . . . . . . . . . . 382<br />

B2205104 . . . . . . . . . . . . . . . . . . . . . . . . . . 388<br />

B2205302 . . . . . . . . . . . . . . . . . . . . . . . . . . 380<br />

B2205401 . . . . . . . . . . . . . . . . . . . . . . . . . . 388<br />

B2205411 . . . . . . . . . . . . . . . . . . . . . . . . . . 389<br />

B2205420 . . . . . . . . . . . . . . . . . . . . . . . . . . 388<br />

B2500080 . . . . . . . . . . . . . . . . . . . . . . . . . . 387<br />

B2500081 . . . . . . . . . . . . . . . . . . . . . . . . . . 389<br />

B2500082 . . . . . . . . . . . . . . . . . . . . . . . . . . 389<br />

B2500083 . . . . . . . . . . . . . . . . . . . . . . . . . . 389<br />

B2500099 . . . . . . . . . . . . . . . . . . . . . . . . . . 395<br />

B2500100 . . . . . . . . . . . . . . . . . . . . . . . . . . 395<br />

B2500103 . . . . . . . . . . . . . . . . . . . . . . . . . . 383<br />

B2500127 . . . . . . . . . . . . . . . . . . . . . . . . . . 391<br />

B2500129 . . . . . . . . . . . . . . . . . . . . . . . . . . 391<br />

B3000001 . . . . . . . . . . . . . . . . . . . . . . . . . . . 25<br />

B3000019 . . . . . . . . . . . . . . . . . . . . . . . . . . . 10<br />

B3000055 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9<br />

B3000111 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8<br />

B3000132 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8<br />

B3000133 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8<br />

B3000135 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8<br />

B3000152 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9<br />

B3000157 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9<br />

B3000158 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9<br />

B3000159 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9<br />

B3000160 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9<br />

B3000161 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9<br />

B3000166 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8<br />

B3000240 . . . . . . . . . . . . . . . . . . . . . . . . . . . 23<br />

B3000243 . . . . . . . . . . . . . . . . . . . . . . . . . . . 22<br />

B3000251 . . . . . . . . . . . . . . . . . . . . . . . . . . . 23<br />

B3000274 . . . . . . . . . . . . . . . . . . . . . . . . . . . 22<br />

B3000277 . . . . . . . . . . . . . . . . . . . . . . . . . . . 22<br />

B3000342 . . . . . . . . . . . . . . . . . . . . . . . . . . . 32<br />

B3000350 . . . . . . . . . . . . . . . . . . . . . . . . 22, 49<br />

B3000641 . . . . . . . . . . . . . . . . . . . . . . . . . . . 34<br />

B3000653 . . . . . . . . . . . . . . . . . . . . . . . . . . . 34<br />

B3000655 . . . . . . . . . . . . . . . . . . . . . . . . . . . 34<br />

B3000656 . . . . . . . . . . . . . . . . . . . . . . . . . . . 45<br />

B3001123 . . . . . . . . . . . . . . . . . . . . . . . . . . . 33<br />

B3001124 . . . . . . . . . . . . . . . . . . . . . . . . . . . 33<br />

B3001254 . . . . . . . . . . . . . . . . . . . . . . . . . . . 32<br />

B3001256 . . . . . . . . . . . . . . . . . . . . . . . . . . . 31<br />

B3001262 . . . . . . . . . . . . . . . . . . . . . . . . . . . 32<br />

Part No. Page Part No. Page Part No. Page


B3001264 – L1200406 Part Number Index<br />

Index<br />

Part Number<br />

413<br />

B3001264 . . . . . . . . . . . . . . . . . . . . . . . . . . . 32<br />

B3001330 . . . . . . . . . . . . . . . . . . . . . . . . . . . 11<br />

B3001333 . . . . . . . . . . . . . . . . . . . . . . . . 10, 12<br />

B3001334 . . . . . . . . . . . . . . . . . . . . . . . . 10, 12<br />

B3001335 . . . . . . . . . . . . . . . . . . . . . . . . . . . 10<br />

B3001465 . . . . . . . . . . . . . . . . . . . . . . . . . . . 11<br />

B3001505 . . . . . . . . . . . . . . . . . . . . . . . . . . . 11<br />

B3001506 . . . . . . . . . . . . . . . . . . . . . . . . . . . 11<br />

B3001507 . . . . . . . . . . . . . . . . . . . . . . . . . . . 11<br />

B3001566 . . . . . . . . . . . . . . . . . . . . . . . . . . . 11<br />

B3001567 . . . . . . . . . . . . . . . . . . . . . . . . . . . 11<br />

B3001647 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8<br />

B3001769 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9<br />

B3001770 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9<br />

B3001771 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9<br />

B3001772 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9<br />

B3002006 . . . . . . . . . . . . . . . . . . . . . . . . . . . 11<br />

B3002007 . . . . . . . . . . . . . . . . . . . . . . . . . . . 11<br />

B3002046 . . . . . . . . . . . . . . . . . . . . . . . . . . . 11<br />

B3002072 . . . . . . . . . . . . . . . . . . . . . . . . . . . 10<br />

B3002076 . . . . . . . . . . . . . . . . . . . . . . . . . . . 10<br />

B3002091 . . . . . . . . . . . . . . . . . . . . . . . . . . . 10<br />

B3002094 . . . . . . . . . . . . . . . . . . . . . . . . . . . 10<br />

B3002097 . . . . . . . . . . . . . . . . . . . . . . . . . . . 10<br />

B3002102 . . . . . . . . . . . . . . . . . . . . . . . . . . . 34<br />

B3002103 . . . . . . . . . . . . . . . . . . . . . . . . . . . 34<br />

B3120405 . . . . . . . . . . . . . . . . . . . . . . . . . . . 34<br />

B3121301 . . . . . . . . . . . . . . . . . . . . . . . . . . . 31<br />

B3130086 . . . . . . . . . . . . . . . . . . . . . . . . . . . 31<br />

B3140123 . . . . . . . . . . . . . . . . . . . . . . . . . . . 10<br />

B3140210 . . . . . . . . . . . . . . . . . . . . . . . . . . . 10<br />

B3140211 . . . . . . . . . . . . . . . . . . . . . . . . . . . 10<br />

B3140226 . . . . . . . . . . . . . . . . . . . . . . . . . . . 10<br />

B3140227 . . . . . . . . . . . . . . . . . . . . . . . . . . . 10<br />

B3140236 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8<br />

B3140244 . . . . . . . . . . . . . . . . . . . . . . . . . . . 10<br />

B3140255 . . . . . . . . . . . . . . . . . . . . . . . . . . . 27<br />

B3140361 . . . . . . . . . . . . . . . . . . . . . . . . . . . 34<br />

B3140362 . . . . . . . . . . . . . . . . . . . . . . . . . . . 34<br />

B3140380 . . . . . . . . . . . . . . . . . . . . . . . . 53, 55<br />

B3140381 . . . . . . . . . . . . . . . . . . . . . . . . . . . 55<br />

B3140382 . . . . . . . . . . . . . . . . . . . . . . . . . . . 54<br />

B3140383 . . . . . . . . . . . . . . . . . . . . . . . . . . . 54<br />

B3140386 . . . . . . . . . . . . . . . . . . . . . . . . . . . 55<br />

B3140387 . . . . . . . . . . . . . . . . . . . . . . . . . . . 55<br />

B3140617 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8<br />

B3140618 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8<br />

B3140621 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8<br />

B3140622 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8<br />

B3140647 . . . . . . . . . . . . . . . . . . . . . . . . 8, 188<br />

B3140715 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8<br />

B3140721 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8<br />

B3140730 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8<br />

B3140760 . . . . . . . . . . . . . . . . . . . . . . . . . . . 49<br />

B3140770 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8<br />

B3141052 . . . . . . . . . . . . . . . . . . . . . . . . . . . 10<br />

B3141064 . . . . . . . . . . . . . . . . . . . . . . . . 33, 67<br />

B3150169 . . . . . . . . . . . . . . . . . . . . . . . . . . . 45<br />

B4000011 . . . . . . . . . . . . . . . . . . . . . . . . . . 147<br />

B4000012 . . . . . . . . . . . . . . . . . . . . . . . . . . 146<br />

B4000022 . . . . . . . . . . . . . . . . . . . . . . . . . . 148<br />

B4000025 . . . . . . . . . . . . . . . . . . . . . . . . . . 148<br />

B4000028 . . . . . . . . . . . . . . . . . . . . . . . . . . 148<br />

B4000033 . . . . . . . . . . . . . . . . . . . . . . . . . . 146<br />

B4000046 . . . . . . . . . . . . . . . . . . . . . . . . . . 144<br />

B4000057 . . . . . . . . . . . . . . . . . . . . . . . . . . 143<br />

C0550303 . . . . . . . . . . . . . . . . . . . . . . . . . . 388<br />

C0550500 . . . . . . . . . . . . . . . . . . . . . . . 45, 397<br />

C0550505 . . . . . . . . . . . . . . . . . . . . . . . . . . 397<br />

C0991141 . . . . . . . . . . . . . . . . . . . . . . . . . . 375<br />

C3220112 . . . . . . . . . . . . . . . . . . . . . . . . . . 375<br />

C3221027 . . . . . . . . . . . . . . . . . . . . . . . . . . 375<br />

C6880054 . . . . . . . . . . . . . . . . . . . . . . . . . . 397<br />

C6880055 . . . . . . . . . . . . . . . . . . . . . . . . . . 397<br />

C6950209 . . . . . . . . . . . . . . . . . . . . . . . . . . 381<br />

C6951019 . . . . . . . . . . . . . . . . . . . . . . . . . . 381<br />

CP183700 . . . . . . . . . . . . . . . . . . . . . . . . . . 387<br />

E5711269 . . . . . . . . . . . . . . . . . . . . . . . . . . 138<br />

E5711272 . . . . . . . . . . . . . . . . . . . . . . . . . . 137<br />

E6070836 . . . . . . . . . . . . . . . . . . . . . . . . . . 137<br />

E6400206 . . . . . . . . . . . . . . . . . . . . . . . . . . 137<br />

E6400207 . . . . . . . . . . . . . . . . . . . . . . . . . . 137<br />

E6400208 . . . . . . . . . . . . . . . . . . . . . . . . . . 137<br />

E6400209 . . . . . . . . . . . . . . . . . . . . . . . . . . 137<br />

E6400211 . . . . . . . . . . . . . . . . . . . . . . . . . . 137<br />

E6400223 . . . . . . . . . . . . . . . . . . . . . . . . . . 137<br />

E6400242 . . . . . . . . . . . . . . . . . . . . . . . . . . 137<br />

E6400247 . . . . . . . . . . . . . . . . . . . . . . . . . . 137<br />

E6400251 . . . . . . . . . . . . . . . . . . . . . . . . . . 137<br />

E6400265 . . . . . . . . . . . . . . . . . . . . . . . . . . 137<br />

E6401017 . . . . . . . . . . . . . . . . . . . . . . . . . . 137<br />

E6401208 . . . . . . . . . . . . . . . . . . . . . . . . . . 137<br />

E6401213 . . . . . . . . . . . . . . . . . . . . . . . . . . 137<br />

E6401214 . . . . . . . . . . . . . . . . . . . . . . . . . . 137<br />

E6401217 . . . . . . . . . . . . . . . . . . . . . . . . . . 137<br />

E6401219 . . . . . . . . . . . . . . . . . . . . . . . . . . 137<br />

E6401220 . . . . . . . . . . . . . . . . . . . . . . . . . . 137<br />

E6401308 . . . . . . . . . . . . . . . . . . . . . . . . . . 138<br />

E6401309 . . . . . . . . . . . . . . . . . . . . . . . . . . 138<br />

E6401384 . . . . . . . . . . . . . . . . . . . . . . . . . . 137<br />

E6420003 . . . . . . . . . . . . . . . . . . . . . . . . . . 138<br />

E6420007 . . . . . . . . . . . . . . . . . . . . . . . . . . 138<br />

E6420021 . . . . . . . . . . . . . . . . . . . . . . . . . . 137<br />

ED020005 . . . . . . . . . . . . . . . . . . . . . . . . . . 323<br />

ED020008 . . . . . . . . . . . . . . . . . . . . . . . . . . 323<br />

ED020015 . . . . . . . . . . . . . . . . . . . . . . . . . . 327<br />

ED020016 . . . . . . . . . . . . . . . . . . . . . . . . . . 327<br />

ED020017 . . . . . . . . . . . . . . . . . . . . . . . . . . 327<br />

L1003006 . . . . . . . . . . . . . . . . . . . . . . 183-184<br />

L1003008 . . . . . . . . . . . . . . . . . . . . . . . . . . 184<br />

L1003012 . . . . . . . . . . . . . . . . . . . . . . . . . . 243<br />

L1003015 . . . . . . . . . . . . . . . . . . . . . . . . . . 181<br />

L1003018 . . . . . . . . . . . . . . . . . . . . . . . . . . 243<br />

L1003020 . . . . . . . . . . . . . . . . . . . . . . 243-244<br />

L1003021 . . . . . . . . . . . . . . . . . . . . . . 243-244<br />

L1003030 . . . . . . . . . . . . . . . . . . . . . . . . . . 183<br />

L1060351 . . . . . . . . . . . . . . . . . . . . . . 258-259<br />

L1100974 . . . . . . . . . . . . . . . . . . . . . . . . . . 264<br />

L1100980 . . . . . . . . . . . . . . . . . . . . . . . . . . 263<br />

L1100981 . . . . . . . . . . . . . . . . . . . . . . . . . . 263<br />

L1108548 . . . . . . . . . . . . . . . . . . . . . . . . . . 262<br />

L1108755 . . . . . . . . . . . . . . . . . . . . . . . . . . 261<br />

L1108757 . . . . . . . . . . . . . . . . . . . . . . . . . . 261<br />

L1108758 . . . . . . . . . . . . . . . . . . . . . . . . . . 261<br />

L1108759 . . . . . . . . . . . . . . . . . . . . . . . . . . 261<br />

L1108760 . . . . . . . . . . . . . . . . . . . . . . . . . . 261<br />

L1108772 . . . . . . . . . . . . . . . . . . . . . . . . . . 261<br />

L1108818 . . . . . . . . . . . . . . . . . . . . . . . . . . 262<br />

L1108822 . . . . . . . . . . . . . . . . . . . . . . . . . . 261<br />

L1108823 . . . . . . . . . . . . . . . . . . . . . . . . . . 261<br />

L1108824 . . . . . . . . . . . . . . . . . . . . . . . . . . 261<br />

L1160333 . . . . . . . . . . . . . . . . . . . . . . . . . . 240<br />

L1160550 . . . . . . . . . . . . . . . . . . . . . . . . . . 252<br />

L1160581 . . . . . . . . . . . . . . . . . . . . . . . . . . 252<br />

L1160582 . . . . . . . . . . . . . . . . . . . . . . . . . . 252<br />

L1160583 . . . . . . . . . . . . . . . . . . . . . . . . . . 252<br />

L1160585 . . . . . . . . . . . . . . . . . . . . . . . . . . 252<br />

L1180480 . . . . . . . . . . . . . . . . . . . . . . . . . . 240<br />

L1180486 . . . . . . . . . . . . . . . . . . . . . . . . . . 240<br />

L1180501 . . . . . . . . . . . . . . . . . . . . . . . . . . 256<br />

L1180502 . . . . . . . . . . . . . . . . . . . . . . . . . . 256<br />

L1180503 . . . . . . . . . . . . . . . . . . . . . . . . . . 256<br />

L1181056 . . . . . . . . . . . . . . . . . . . . . . . . . . 241<br />

L1181257 . . . . . . . . . . . . . . . . . . . . . . . . . . 256<br />

L1181301 . . . . . . . . . . . . . . . . . . . . . . . . . . 249<br />

L1181302 . . . . . . . . . . . . . . . . . . . . . . . . . . 249<br />

L1181303 . . . . . . . . . . . . . . . . . . . . . . . . . . 249<br />

L1181304 . . . . . . . . . . . . . . . . . . . . . . . . . . 249<br />

L1181314 . . . . . . . . . . . . . . . . . . . . . . . . . . 260<br />

L1181316 . . . . . . . . . . . . . . . . . . . . . . . . . . 260<br />

L1181318 . . . . . . . . . . . . . . . . . . . . . . . . . . 256<br />

L1181319 . . . . . . . . . . . . . . . . . . . . . . . . . . 256<br />

L1181322 . . . . . . . . . . . . . . . . . . . . . . . . . . 241<br />

L1185153 . . . . . . . . . . . . . . . . . . . . . . . . . . 256<br />

L1185305 . . . . . . . . . . . . . . . . . . . . . . . . . . 256<br />

L1191014 . . . . . . . . . . . . . . . . . . . . . . . . . . 242<br />

L1191015 . . . . . . . . . . . . . . . . . . . . . . . . . . 243<br />

L1191018 . . . . . . . . . . . . . . . . . . . . . . . . . . 242<br />

L1191021 . . . . . . . . . . . . . . . . . . . . . . . . . . 242<br />

L1191031 . . . . . . . . . . . . . . . . . . . . . . . . . . 243<br />

L1191079 . . . . . . . . . . . . . . . . . . . . . . . . . . 242<br />

L1191080 . . . . . . . . . . . . . . . . . . . . . . . . . . 242<br />

L1191081 . . . . . . . . . . . . . . . . . . . . . . . . . . 242<br />

L1191082 . . . . . . . . . . . . . . . . . . . . . . . . . . 242<br />

L1191099 . . . . . . . . . . . . . . . . . . . . . . . . . . 242<br />

L1191113 . . . . . . . . . . . . . . . . . . . . . . . . . . 242<br />

L1191114 . . . . . . . . . . . . . . . . . . . . . . . . . . 243<br />

L1191202 . . . . . . . . . . . . . . . . . . . . . . . . . . 242<br />

L1191207 . . . . . . . . . . . . . . . . . . . . . . . . . . 242<br />

L1191210 . . . . . . . . . . . . . . . . . . . . . . . . . . 242<br />

L1191211 . . . . . . . . . . . . . . . . . . . . . . . . . . 242<br />

L1195019 . . . . . . . . . . . . . . . . . . . . . . . . . . 242<br />

L1200205 . . . . . . . . . . . . . . . . . . . . . . . . . . 265<br />

L1200214 . . . . . . . . . . . . . . . . . . . . . . . . . . 240<br />

L1200216 . . . . . . . . . . . . . . . . . . . . . . . . . . 240<br />

L1200219 . . . . . . . . . . . . . . . . . . . . . . . . . . 240<br />

L1200220 . . . . . . . . . . . . . . . . . . . . . . . . . . 265<br />

L1200223 . . . . . . . . . . . . . . . . . . . . . . . . . . 265<br />

L1200236 . . . . . . . . . . . . . . . . . . . . . . . . . . 265<br />

L1200237 . . . . . . . . . . . . . . . . . . . . . . . . . . 265<br />

L1200238 . . . . . . . . . . . . . . . . . . . . . . . . . . 265<br />

L1200241 . . . . . . . . . . . . . . . . . . . . . . . . . . 265<br />

L1200253 . . . . . . . . . . . . . . . . . . . . . . . . . . 240<br />

L1200254 . . . . . . . . . . . . . . . . . . . . . . . . . . 265<br />

L1200301 . . . . . . . . . . . . . . . . . . . . . . . . . . 265<br />

L1200302 . . . . . . . . . . . . . . . . . . . . . . . . . . 265<br />

L1200306 . . . . . . . . . . . . . . . . . . . . . . . . . . 244<br />

L1200308 . . . . . . . . . . . . . . . . . . . . . . . . . . 244<br />

L1200309 . . . . . . . . . . . . . . . . . . . . . . . . . . 244<br />

L1200310 . . . . . . . . . . . . . . . . . . . . . . . . . . 244<br />

L1200313 . . . . . . . . . . . . . . . . . . . . . . . . . . 255<br />

L1200314 . . . . . . . . . . . . . . . . . . . . . . . . . . 255<br />

L1200315 . . . . . . . . . . . . . . . . . . . . . . . . . . 255<br />

L1200316 . . . . . . . . . . . . . . . . . . . . . . . . . . 255<br />

L1200321 . . . . . . . . . . . . . . . . . . . . . . . . . . 256<br />

L1200323 . . . . . . . . . . . . . . . . . . . . . . . . . . 255<br />

L1200324 . . . . . . . . . . . . . . . . . . . . . . . . . . 255<br />

L1200325 . . . . . . . . . . . . . . . . . . . . . . . . . . 255<br />

L1200333 . . . . . . . . . . . . . . . . . . . . . . . . . . 255<br />

L1200334 . . . . . . . . . . . . . . . . . . . . . . . . . . 255<br />

L1200335 . . . . . . . . . . . . . . . . . . . . . . . . . . 255<br />

L1200336 . . . . . . . . . . . . . . . . . . . . . . . . . . 255<br />

L1200337 . . . . . . . . . . . . . . . . . . . . . . . . . . 255<br />

L1200338 . . . . . . . . . . . . . . . . . . . . . . . . . . 255<br />

L1200343 . . . . . . . . . . . . . . . . . . . . . . . . . . 255<br />

L1200344 . . . . . . . . . . . . . . . . . . . . . . . . . . 255<br />

L1200345 . . . . . . . . . . . . . . . . . . . . . . . . . . 255<br />

L1200346 . . . . . . . . . . . . . . . . . . . . . . . . . . 255<br />

L1200364 . . . . . . . . . . . . . . . . . . . . . . . . . . 256<br />

L1200365 . . . . . . . . . . . . . . . . . . . . . . . . . . 256<br />

L1200366 . . . . . . . . . . . . . . . . . . . . . . . . . . 256<br />

L1200390 . . . . . . . . . . . . . . . . . . . . . . . . . . 265<br />

L1200392 . . . . . . . . . . . . . . . . . . . . . . . . . . 265<br />

L1200393 . . . . . . . . . . . . . . . . . . . . . . . . . . 256<br />

L1200394 . . . . . . . . . . . . . . . . . . . . . . . . . . 255<br />

L1200406 . . . . . . . . . . . . . . . . . . . . . . . . . . 241<br />

Part No. Page Part No. Page Part No. Page<br />

See page 4 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

See page 2 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong>


Index Part Number L1200551 – LX100846<br />

Index<br />

Part Number<br />

414<br />

L1200551 . . . . . . . . . . . . . . . . . . . . . . . . . . 243<br />

L1200552 . . . . . . . . . . . . . . . . . . . . . . . . . . 243<br />

L1200553 . . . . . . . . . . . . . . . . . . . . . . . . . . 243<br />

L1200555 . . . . . . . . . . . . . . . . . . . . . . . . . . 242<br />

L1200556 . . . . . . . . . . . . . . . . . . . . . . . . . . 243<br />

L1200557 . . . . . . . . . . . . . . . . . . . . . . . . . . 243<br />

L1200558 . . . . . . . . . . . . . . . . . . . . . . . . . . 242<br />

L1200559 . . . . . . . . . . . . . . . . . . . . . . . . . . 243<br />

L1200560 . . . . . . . . . . . . . . . . . . . . . . . . . . 243<br />

L1200574 . . . . . . . . . . . . . . . . . . . . . . . . . . 243<br />

L1200587 . . . . . . . . . . . . . . . . . . . . . . . . . . 243<br />

L1200588 . . . . . . . . . . . . . . . . . . . . . . . . . . 243<br />

L1200589 . . . . . . . . . . . . . . . . . . . . . . . . . . 243<br />

L1201231 . . . . . . . . . . . . . . . . . . . . . . . . . . 244<br />

L1201654 . . . . . . . . . . . . . . . . . . . . . . . . . . 255<br />

L1201655 . . . . . . . . . . . . . . . . . . . . . . . . . . 255<br />

L1201865 . . . . . . . . . . . . . . . . . . . . . . . . . . 255<br />

L1201904 . . . . . . . . . . . . . . . . . . . . . . . . . . 244<br />

L1201905 . . . . . . . . . . . . . . . . . . . . . . . . . . 244<br />

L1201989 . . . . . . . . . . . . . . . . . . . . . . . . . . 244<br />

L1202006 . . . . . . . . . . . . . . . . . . . . . . . . . . 244<br />

L1202035 . . . . . . . . . . . . . . . . . . . . . . . . . . 244<br />

L1202036 . . . . . . . . . . . . . . . . . . . . . . . . . . 244<br />

L1202037 . . . . . . . . . . . . . . . . . . . . . . . . . . 244<br />

L1202057 . . . . . . . . . . . . . . . . . . . . . . . . . . 241<br />

L1202715 . . . . . . . . . . . . . . . . . . . . . . . . . . 244<br />

L1202716 . . . . . . . . . . . . . . . . . . . . . . . . . . 244<br />

L1240053 . . . . . . . . . . . . . . . . . . . . . . . . . . 256<br />

L1240055 . . . . . . . . . . . . . . . . . . . . . . . . . . 249<br />

L1240056 . . . . . . . . . . . . . . . . . . . . . . . . . . 249<br />

L1240057 . . . . . . . . . . . . . . . . . . . . . . . . . . 249<br />

L1240062 . . . . . . . . . . . . . . . . . . . . . . . . . . 260<br />

L1240097 . . . . . . . . . . . . . . . . . . . . . . . . . . 240<br />

L1240098 . . . . . . . . . . . . . . . . . . . . . . . . . . 241<br />

L1240204 . . . . . . . . . . . . . . . . . . . . . . . . . . 265<br />

L1241555 . . . . . . . . . . . . . . . . . . . . . . . . . . 245<br />

L1241556 . . . . . . . . . . . . . . . . . . . . . . . . . . 245<br />

L1241557 . . . . . . . . . . . . . . . . . . . . . . . . . . 245<br />

L1241558 . . . . . . . . . . . . . . . . . . . . . . . . . . 245<br />

L1241559 . . . . . . . . . . . . . . . . . . . . . . . . . . 245<br />

L1241571 . . . . . . . . . . . . . . . . . . . . . . . . . . 245<br />

L1241572 . . . . . . . . . . . . . . . . . . . . . . . . . . 245<br />

L1241573 . . . . . . . . . . . . . . . . . . . . . . . . . . 245<br />

L1241574 . . . . . . . . . . . . . . . . . . . . . . . . . . 245<br />

L1241575 . . . . . . . . . . . . . . . . . . . . . . . . . . 245<br />

L1245024 . . . . . . . . . . . . . . . . . . . . . . . . . . 245<br />

L1245221 . . . . . . . . . . . . . . . . . . . . . . . . . . 260<br />

L1270301 . . . . . . . . . . . . . . . . . . . . . . . . . . 251<br />

L1270402 . . . . . . . . . . . . . . . . . . . . . . . . . . 251<br />

L1270404 . . . . . . . . . . . . . . . . . . . . . . . . . . 251<br />

L1270408 . . . . . . . . . . . . . . . . . . . . . . . . . . 251<br />

L1270409 . . . . . . . . . . . . . . . . . . . . . . . . . . 251<br />

L1270410 . . . . . . . . . . . . . . . . . . . . . . . . . . 251<br />

L1270421 . . . . . . . . . . . . . . . . . . . . . . . . . . 251<br />

L1270503 . . . . . . . . . . . . . . . . . . . . . . . . . . 258<br />

L1270504 . . . . . . . . . . . . . . . . . . . . . . . . . . 258<br />

L1270512 . . . . . . . . . . . . . . . . . . . . . . 248, 251<br />

L1270664 . . . . . . . . . . . . . . . . . . . . . . . . . . 251<br />

L1270665 . . . . . . . . . . . . . . . . . . . . . . . . . . 248<br />

L1270666 . . . . . . . . . . . . . . . . . . . . . . . . . . 251<br />

L1270741 . . . . . . . . . . . . . . . . . . . . . . . . . . 251<br />

L1270742 . . . . . . . . . . . . . . . . . . . . . . . . . . 251<br />

L1270744 . . . . . . . . . . . . . . . . . . . . . . . . . . 251<br />

L1270747 . . . . . . . . . . . . . . . . . . . . . . . . . . 251<br />

L1270748 . . . . . . . . . . . . . . . . . . . . . . . . . . 251<br />

L1270749 . . . . . . . . . . . . . . . . . . . . . . . . . . 251<br />

L1270751 . . . . . . . . . . . . . . . . . . . . . . . . . . 251<br />

L1270752 . . . . . . . . . . . . . . . . . . . . . . . . . . 251<br />

L1270754 . . . . . . . . . . . . . . . . . . . . . . . . . . 251<br />

L1270757 . . . . . . . . . . . . . . . . . . . . . . . . . . 251<br />

L1270758 . . . . . . . . . . . . . . . . . . . . . . . . . . 251<br />

L1270759 . . . . . . . . . . . . . . . . . . . . . . . . . . 251<br />

L1270761 . . . . . . . . . . . . . . . . . . . . . . . . . . 251<br />

L1270762 . . . . . . . . . . . . . . . . . . . . . . . . . . 251<br />

L1270764 . . . . . . . . . . . . . . . . . . . . . . . . . . 251<br />

L1270765 . . . . . . . . . . . . . . . . . . . . . . . . . . 251<br />

L1270766 . . . . . . . . . . . . . . . . . . . . . . 248, 250<br />

L1270767 . . . . . . . . . . . . . . . . . . . . . . . . . . 251<br />

L1270768 . . . . . . . . . . . . . . . . . . . . . . . . . . 251<br />

L1270769 . . . . . . . . . . . . . . . . . . . . . . . . . . 251<br />

L1270941 . . . . . . . . . . . . . . . . . . . . . . . . . . 250<br />

L1270942 . . . . . . . . . . . . . . . . . . . . . . . . . . 250<br />

L1270944 . . . . . . . . . . . . . . . . . . . . . . . . . . 250<br />

L1270947 . . . . . . . . . . . . . . . . . . . . . . . . . . 250<br />

L1270948 . . . . . . . . . . . . . . . . . . . . . . . . . . 250<br />

L1270949 . . . . . . . . . . . . . . . . . . . . . . . . . . 250<br />

L1270951 . . . . . . . . . . . . . . . . . . . . . . . . . . 250<br />

L1270952 . . . . . . . . . . . . . . . . . . . . . . . . . . 250<br />

L1270954 . . . . . . . . . . . . . . . . . . . . . . . . . . 250<br />

L1270957 . . . . . . . . . . . . . . . . . . . . . . . . . . 250<br />

L1270958 . . . . . . . . . . . . . . . . . . . . . . . . . . 250<br />

L1270959 . . . . . . . . . . . . . . . . . . . . . . . . . . 250<br />

L1270961 . . . . . . . . . . . . . . . . . . . . . . . . . . 250<br />

L1270962 . . . . . . . . . . . . . . . . . . . . . . . . . . 250<br />

L1270964 . . . . . . . . . . . . . . . . . . . . . . . . . . 250<br />

L1270967 . . . . . . . . . . . . . . . . . . . . . . . . . . 250<br />

L1270968 . . . . . . . . . . . . . . . . . . . . . . . . . . 250<br />

L1270969 . . . . . . . . . . . . . . . . . . . . . . . . . . 250<br />

L1270970 . . . . . . . . . . . . . . . . . . . . . . . . . . 250<br />

L1270986 . . . . . . . . . . . . . . . . . . . . . . 248, 251<br />

L1271012 . . . . . . . . . . . . . . . . . . . . . . . . . . 255<br />

L1271013 . . . . . . . . . . . . . . . . . . . . . . . . . . 255<br />

L1271021 . . . . . . . . . . . . . . . . . . . . . . . . . . 255<br />

L1271025 . . . . . . . . . . . . . . . . . . . . . . . . . . 259<br />

L1271026 . . . . . . . . . . . . . . . . . . . . . . . . . . 259<br />

L1271027 . . . . . . . . . . . . . . . . . . . . . . . . . . 259<br />

L1271102 . . . . . . . . . . . . . . . . . . . . . . 248, 250<br />

L1271191 . . . . . . . . . . . . . . . . . . . . . . . . . . 251<br />

L1271192 . . . . . . . . . . . . . . . . . . . . . . . . . . 251<br />

L1271193 . . . . . . . . . . . . . . . . . . . . . . . . . . 251<br />

L1271194 . . . . . . . . . . . . . . . . . . . . . . . . . . 251<br />

L1271195 . . . . . . . . . . . . . . . . . . . . . . . . . . 251<br />

L1271202 . . . . . . . . . . . . . . . . . . . . . . 248, 250<br />

L1271250 . . . . . . . . . . . . . . . . . . . . . . . . . . 248<br />

L1271602 . . . . . . . . . . . . . . . . . . . . . . 248, 250<br />

L1272002 . . . . . . . . . . . . . . . . . . . . . . 248, 250<br />

L1272102 . . . . . . . . . . . . . . . . . . . . . . . . . . 248<br />

L1275102 . . . . . . . . . . . . . . . . . . . . . . . . . . 255<br />

L1275105 . . . . . . . . . . . . . . . . . . . . . . . . . . 255<br />

L1275106 . . . . . . . . . . . . . . . . . . . . . . . . . . 255<br />

L1304040 . . . . . . . . . . . . . . . . . . . . . . . . . . 249<br />

L1360266 . . . . . . . . . . . . . . . . . . . . . . . . . . 255<br />

L1360267 . . . . . . . . . . . . . . . . . . . . . . . . . . 255<br />

L1360268 . . . . . . . . . . . . . . . . . . . . . . . . . . 255<br />

L1360269 . . . . . . . . . . . . . . . . . . . . . . . . . . 255<br />

L1360270 . . . . . . . . . . . . . . . . . . . . . . . . . . 255<br />

L1360271 . . . . . . . . . . . . . . . . . . . . . . . . . . 255<br />

L1360272 . . . . . . . . . . . . . . . . . . . . . . . . . . 255<br />

L1360273 . . . . . . . . . . . . . . . . . . . . . . . . . . 255<br />

L1360274 . . . . . . . . . . . . . . . . . . . . . . . . . . 256<br />

L1360275 . . . . . . . . . . . . . . . . . . . . . . . . . . 256<br />

L1362300 . . . . . . . . . . . . . . . . . . . . . . . . . . 241<br />

L1362307 . . . . . . . . . . . . . . . . . . . . . . . . . . 241<br />

L1365311 . . . . . . . . . . . . . . . . . . . . . . . . . . 257<br />

L1365312 . . . . . . . . . . . . . . . . . . . . . . . . . . 257<br />

L1860221 . . . . . . . . . . . . . . . . . . . . . . . . . . 259<br />

L1860249 . . . . . . . . . . . . . . . . . . . . . . . . . . 254<br />

L1860250 . . . . . . . . . . . . . . . . . . . . . . . . . . 254<br />

L1860268 . . . . . . . . . . . . . . . . . . . . . . . . . . 253<br />

L1860269 . . . . . . . . . . . . . . . . . . . . . . . . . . 253<br />

L1860279 . . . . . . . . . . . . . . . . . . . . . . . . . . 262<br />

L1860298 . . . . . . . . . . . . . . . . . . . . . . . . . . 265<br />

L1860305 . . . . . . . . . . . . . . . . . . . . . . . . . . 262<br />

L1860408 . . . . . . . . . . . . . . . . . . . . . . . . . . 259<br />

L1860409 . . . . . . . . . . . . . . . . . . . . . . . . . . 253<br />

L1861634 . . . . . . . . . . . . . . . . . . . . . . . . . . 253<br />

L1861789 . . . . . . . . . . . . . . . . . . . . . . 253-254<br />

L1861790 . . . . . . . . . . . . . . . . . . . . . . 253-254<br />

L1871106 . . . . . . . . . . . . . . . . . . . . . . . . . . 249<br />

L2251157 . . . . . . . . . . . . . . . . . . . . . . . . . . 315<br />

L4070023 . . . . . . . . . . . . . . . . . . . . . . . . . . 182<br />

L4070207 . . . . . . . . . . . . . . . . . . . . . . . . . . 181<br />

L4070208 . . . . . . . . . . . . . . . . . . . . . . . . . . 181<br />

L4071029 . . . . . . . . . . . . . . . . . . . . . . . . . . 181<br />

L4071034 . . . . . . . . . . . . . . . . . . . . . . . . . . 181<br />

L4071123 . . . . . . . . . . . . . . . . . . . . . . . . . . 181<br />

L4071151 . . . . . . . . . . . . . . . . . . . . . . . . . . 182<br />

L4071594 . . . . . . . . . . . . . . . . . . . . . . . . . . 181<br />

L4135472 . . . . . . . . . . . . . . . . . . . . . . . . . . 135<br />

L4270009 . . . . . . . . . . . . . . . . . . . . . . . . . . 183<br />

L4270010 . . . . . . . . . . . . . . . . . . . . . . . . . . 183<br />

L4270026 . . . . . . . . . . . . . . . . . . . . . . . . . . 182<br />

L4270032 . . . . . . . . . . . . . . . . . . . . . . . . . . 182<br />

L4270034 . . . . . . . . . . . . . . . . . . . . . . . . . . 182<br />

L4270128 . . . . . . . . . . . . . . . . . . . . . . . . . . 181<br />

L4270129 . . . . . . . . . . . . . . . . . . . . . . . . . . 181<br />

L4271106 . . . . . . . . . . . . . . . . . . . . . . . . . . 182<br />

L4271159 . . . . . . . . . . . . . . . . . . . . . . 181, 183<br />

L4271160 . . . . . . . . . . . . . . . . . . . . . . . . . . 184<br />

L4271187 . . . . . . . . . . . . . . . . . . . . . . 182-183<br />

L4271203 . . . . . . . . . . . . . . . . . . . . . . . . . . 183<br />

L4271275 . . . . . . . . . . . . . . . . . . . . . . . . . . 180<br />

L4271290 . . . . . . . . . . . . . . . . . . . . . . . . . . 183<br />

L4275009 . . . . . . . . . . . . . . . . . . . . . . . . . . 182<br />

L4275033 . . . . . . . . . . . . . . . . . . . . . . . . . . 180<br />

L4275072 . . . . . . . . . . . . . . . . . . . . . . . . . . 183<br />

L4275089 . . . . . . . . . . . . . . . . . . . . . . . . . . 182<br />

L4275107 . . . . . . . . . . . . . . . . . . . . . . . . . . 182<br />

L4275108 . . . . . . . . . . . . . . . . . . . . . . 180, 182<br />

L4275110 . . . . . . . . . . . . . . . . . . . . . . 182, 184<br />

L4280001 . . . . . . . . . . . . . . . . . . . . . . . . . . 180<br />

L4280002 . . . . . . . . . . . . . . . . . . . . . . . . . . 180<br />

L4280003 . . . . . . . . . . . . . . . . . . . . . . . . . . 180<br />

L4281023 . . . . . . . . . . . . . . . . . . . . . . . . . . 180<br />

L4285001 . . . . . . . . . . . . . . . . . . . . . . . . . . 180<br />

L4285007 . . . . . . . . . . . . . . . . . . . . . . . . . . 180<br />

L4831520 . . . . . . . . . . . . . . . . . . . . . . . . . . 241<br />

L6020211 . . . . . . . . . . . . . . . . . . . . . . . . . . 381<br />

L6020290 . . . . . . . . . . . . . . . . . . . . . . . . . . 380<br />

L6100013 . . . . . . . . . . . . . . . . . . . . . . . . . . 398<br />

L6100046 . . . . . . . . . . . . . . . . . . . . . . . . . . 398<br />

L6100047 . . . . . . . . . . . . . . . . . . . . . . . . . . 398<br />

L6100048 . . . . . . . . . . . . . . . . . . . . . . . . . . 398<br />

L6100049 . . . . . . . . . . . . . . . . . . . . . . . . . . 398<br />

L6100081 . . . . . . . . . . . . . . . . . . . . . . . . . . 400<br />

L6100082 . . . . . . . . . . . . . . . . . . . . . . . . . . 400<br />

L6100095 . . . . . . . . . . . . . . . . . . . . . . . . . . 398<br />

L6100096 . . . . . . . . . . . . . . . . . . . . . . . . . . 398<br />

L6100097 . . . . . . . . . . . . . . . . . . . . . . . . . . 398<br />

L6100098 . . . . . . . . . . . . . . . . . . . . . . . . . . 398<br />

L6100099 . . . . . . . . . . . . . . . . . . . . . . . . . . 398<br />

L6100102 . . . . . . . . . . . . . . . . . . . . . . . . . . 398<br />

L6100103 . . . . . . . . . . . . . . . . . . . . . . . . . . 398<br />

L6100104 . . . . . . . . . . . . . . . . . . . . . . . . . . 398<br />

L6100105 . . . . . . . . . . . . . . . . . . . . . . . . . . 398<br />

L6100114 . . . . . . . . . . . . . . . . . . . . . . . . . . 398<br />

L6100115 . . . . . . . . . . . . . . . . . . . . . . . . . . 398<br />

L6100116 . . . . . . . . . . . . . . . . . . . . . . . . . . 398<br />

L6100117 . . . . . . . . . . . . . . . . . . . . . . . . . . 398<br />

L6310010 . . . . . . . . . . . . . . . . . . . . . . . . . . 386<br />

L6310011 . . . . . . . . . . . . . . . . . . . . . . . . . . 386<br />

L9001029 . . . . . . . . . . . . . . . . . . . . . . 245, 256<br />

L9001162 . . . . . . . . . . . . . . . . . . . . . . . . . . 260<br />

LX100689 . . . . . . . . . . . . . . . . . . . . . . . . . . 262<br />

LX100690 . . . . . . . . . . . . . . . . . . . . . . . . . . 262<br />

LX100846 . . . . . . . . . . . . . . . . . . . . . . . . . . 263<br />

Part No. Page Part No. Page Part No. Page


LX100847 – N0772026 Part Number Index<br />

Index<br />

Part Number<br />

415<br />

LX100847 . . . . . . . . . . . . . . . . . . . . . . . . . . 264<br />

LX100849 . . . . . . . . . . . . . . . . . . . . . . . . . . 263<br />

LX100850 . . . . . . . . . . . . . . . . . . . . . . . . . . 264<br />

LX108640 . . . . . . . . . . . . . . . . . . . . . . . . . . 262<br />

LX108689 . . . . . . . . . . . . . . . . . . . . . . . . . . 263<br />

LX108848 . . . . . . . . . . . . . . . . . . . . . . . . . . 263<br />

LX108849 . . . . . . . . . . . . . . . . . . . . . . . . . . 264<br />

LX108850 . . . . . . . . . . . . . . . . . . . . . . . . . . 264<br />

M0410316 . . . . . . . . . . . . . . . . . . . . . . 183-184<br />

M0413331 . . . . . . . . . . . . . . . . . . . . . . . . . 183<br />

M0413348 . . . . . . . . . . . . . . . . . . . . . . . . . 145<br />

M0413380 . . . . . . . . . . . . . . . . . . . . . . . . . 183<br />

M0413401 . . . . . . . . . . . . . . . . . . . . . . . . . 144<br />

M0413535 . . . . . . . . . . . . . . . . . . . . . . . . . 184<br />

M0413541 . . . . . . . . . . . . . . . . . . . . . . . . . 182<br />

M0413545 . . . . . . . . . . . . . . . . . . . . . . . . . 147<br />

M0413546 . . . . . . . . . . . . . . . . . . . . . . . . . 147<br />

M0413547 . . . . . . . . . . . . . . . . . . . . . . . . . 147<br />

M0413548 . . . . . . . . . . . . . . . . . . . . . . . . . 143<br />

M0413549 . . . . . . . . . . . . . . . . . . . . . . . . . 143<br />

M0413550 . . . . . . . . . . . . . . . . . . . . . . . . . 143<br />

M0413551 . . . . . . . . . . . . . . . . . . . . . 143, 184<br />

M0413552 . . . . . . . . . . . . . . . . . . . . . . . . . 144<br />

M0413553 . . . . . . . . . . . . . . . . . . . . . . . . . 184<br />

M0413555 . . . . . . . . . . . . . . . . . . . . . . . . . 184<br />

M0413556 . . . . . . . . . . . . . . . . . . . . . . . . . 184<br />

M0413557 . . . . . . . . . . . . . . . . . . . . . . . . . 184<br />

M0413558 . . . . . . . . . . . . . . . . . . . . . . . . . 183<br />

M0413559 . . . . . . . . . . . . . . . . . . . . . . . . . 183<br />

M0413592 . . . . . . . . . . . . . . . . . . . . . . . . . 145<br />

M0413593 . . . . . . . . . . . . . . . . . . . . . . . . . 145<br />

M0413595 . . . . . . . . . . . . . . . . . . . . . . . . . 181<br />

M0413596 . . . . . . . . . . . . . . . . . . . . . . . . . 181<br />

M0413597 . . . . . . . . . . . . . . . . . . . . . . . . . 181<br />

M0413598 . . . . . . . . . . . . . . . . . . . . . . . . . 181<br />

M0413625 . . . . . . . . . . . . . . . . . . . . . . . . . 181<br />

M0413627 . . . . . . . . . . . . . . . . . . . . . . . . . 184<br />

M0413628 . . . . . . . . . . . . . . . . . . . . . . . . . 184<br />

M0413643 . . . . . . . . . . . . . . . . . . . . . . . . . 144<br />

M0413644 . . . . . . . . . . . . . . . . . . . . . . . . . 183<br />

M0413645 . . . . . . . . . . . . . . . . . . . . . . . . . 183<br />

M0413646 . . . . . . . . . . . . . . . . . . . . . . . . . 184<br />

M0415339 . . . . . . . . . . . . . . . . . . . . . . . . . 183<br />

M0415360 . . . . . . . . . . . . . . . . . . . . . . . . . 184<br />

M0415361 . . . . . . . . . . . . . . . . . . . . . . . . . 184<br />

N0171159 . . . . . . . . . . . . . . . . . . . . . . . . . . 240<br />

N0200015 . . . . . . . . . . . . . . . . . . . . . . . . . . 346<br />

N0370119 . . . . . . . . . . . . . . . . . . . . . . . . . . . 45<br />

N0370149 . . . . . . . . . . . . . . . . . . . . . . . . . . . 14<br />

N0370392 . . . . . . . . . . . . . . . . . . . . . . . . . . . 13<br />

N0370393 . . . . . . . . . . . . . . . . . . . . . . . . 17-18<br />

N0370394 . . . . . . . . . . . . . . . . . . . . . . . . 17-18<br />

N0370398 . . . . . . . . . . . . . . . . . . . . . . . . . . . 18<br />

N0370399 . . . . . . . . . . . . . . . . . . . . . . . . . . . 18<br />

N0371485 . . . . . . . . . . . . . . . . . . . . . . . . . . . 18<br />

N0371492 . . . . . . . . . . . . . . . . . . . . . . . . . . . 18<br />

N0371493 . . . . . . . . . . . . . . . . . . . . . . . . . . . 18<br />

N0371505 . . . . . . . . . . . . . . . . . . . . . . . 18, 222<br />

N0371520 . . . . . . . . . . . . . . . . . . . . . . . . . . . 18<br />

N0371522 . . . . . . . . . . . . . . . . . . . . . . . . . . . 18<br />

N0400058 . . . . . . . . . . . . . . . . . . . . . . . . . . . 13<br />

N0400100 . . . . . . . . . . . . . . . . . . . . . . . . . . . 13<br />

N0400101 . . . . . . . . . . . . . . . . . . . . . . . . . . . 13<br />

N0400102 . . . . . . . . . . . . . . . . . . . . . . . . . . . 13<br />

N0400103 . . . . . . . . . . . . . . . . . . . . . . . . . . . 13<br />

N0401171 . . . . . . . . . . . . . . . . . . . . . . . . . . . 13<br />

N0410100 . . . . . . . . . . . . . . . . . . . . . . . . . . . 48<br />

N0580528 . . . . . . . . . . . . . . . . . . . . . . . . . . 227<br />

N0580531 . . . . . . . . . . . . . . . . . . . . . . . . . . . 36<br />

N0580534 . . . . . . . . . . . . . . . . . . . . . . . . . . 229<br />

N0580539 . . . . . . . . . . . . . . . . . . . . . . 220, 228<br />

N0580540 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9<br />

N0580542 . . . . . . . . . . . . . . . . . . . . . . . . . . 226<br />

N0580624 . . . . . . . . . . . . . . . . . . . . . . 197, 223<br />

N0581455 . . . . . . . . . . . . . . . . . . . . . . . . . . 219<br />

N0581497 . . . . . . . . . . . . . . . . . . . . . . . . . . 219<br />

N0581558 . . . . . . . . . . . . . . . . . . . . . . . . . . 229<br />

N0581793 . . . . . . . . . . . . . . . . . . . . . . . . . . 229<br />

N0582152 . . . . . . . . . . . . . . . . . . . . . . . . . . 236<br />

N0582184 . . . . . . . . . . . . . . . . . . . . . . 220, 229<br />

N0582185 . . . . . . . . . . . . . . . . . . . . . . . . . . 220<br />

N0582186 . . . . . . . . . . . . . . . . . . . . . . . . . . 220<br />

N0582248 . . . . . . . . . . . . . . . . . . . . . . . . . . 220<br />

N0582251 . . . . . . . . . . . . . . . . . . . . . . . 36, 216<br />

N0582258 . . . . . . . . . . . . . . . . . . . . . . 226, 229<br />

N0582259 . . . . . . . . . . . . . . . . . . . . . . . . . . 226<br />

N0650230 . . . . . . . . . . . . . . . . . . . . . . . . . . 218<br />

N0660122 . . . . . . . . . . . . . . . . . . . . . . . . . . . 44<br />

N0660123 . . . . . . . . . . . . . . . . . . . . . . . . . . . 44<br />

N0680212 . . . . . . . . . . . . . . . . . . . . . . . . . . 219<br />

N0680241 . . . . . . . . . . . . . . . . . . . . . . . . . . 228<br />

N0680275 . . . . . . . . . . . . . . . . . . . . . . . . . . 219<br />

N0680375 . . . . . . . . . . . . . . . . . . . . . . 199, 224<br />

N0680376 . . . . . . . . . . . . . . . . . . . . . . 199, 224<br />

N0680503 . . . . . . . . . . . . . . . . . . . . . . 223, 229<br />

N0680504 . . . . . . . . . . . . . . 197, 218, 221-222<br />

N0680610 . . . . . . . . . . . . . . . . . . . . . . . . . . 223<br />

N0680612 . . . . . . . . . . . . . . . . . . . . . . . . . . 198<br />

N0681234 . . . . . . . . . . . . . . . . . . . . . . . . . . 219<br />

N0681470 . . . . . . . . . . . . . . . . . . . . . . . . . . 236<br />

N0681574 . . . . . . . . . . . . . . . . . . . . . . 196, 221<br />

N0681581 . . . . . . . . . . . . . . . . . . . . . . . . . . 236<br />

N0681631 . . . . . . . . . . . . . . . . . . . . . . 195, 220<br />

N0681690 . . . . . . . . . . . . . . . . . . . . . . . . . . 227<br />

N0690262 . . . . . . . . . . . . . . . . . . . . . . . . . . 224<br />

N0690269 . . . . . . . . . . . . . . . . . . . . . . 220, 228<br />

N0690271 . . . . . . . . . . . . . . . . . . . . . . 204, 218<br />

N0690284 . . . . . . . . . . . . . . . . . . . . . . . . . . 224<br />

N0690287 . . . . . . . . . . . . . . . . . . . . . . . . . . 218<br />

N0690288 . . . . . . . . . . . . . . . . . . . . . . . . . . 218<br />

N0690289 . . . . . . . . . . . . . . . . . . . . . . . . . . 226<br />

N0690360 . . . . . . . . . . . . . . . . . . . . . . . . . . 224<br />

N0690568 . . . . . . . . . . . . . . . . . . . . . . 227, 229<br />

N0690572 . . . . . . . . . . . . . . . . . . . . . . . . . . 219<br />

N0690593 . . . . . . . . . . . . . . . . . . . . . . . . . . 229<br />

N0690607 . . . . . . . . . . . . . . . . . . . . . . 228-230<br />

N0690610 . . . . . . . . . . . . . . . . . . . . . . . . . . 227<br />

N0690636 . . . . . . . . . . . . . . . . . . . . . . . . . . 227<br />

N0690637 . . . . . . . . . . . . . . . . . . . . . . . . . . 228<br />

N0690638 . . . . . . . . . . . . . . . . . . . . . . . . . . 228<br />

N0690639 . . . . . . . . . . . . . . . . . . . . . . . . . . 224<br />

N0690640 . . . . . . . . . . . . . . . . . . . . . . . . . . 226<br />

N0690666 . . . . . . . . . . . . . . . . . . . . . . . . . . 219<br />

N0690668 . . . . . . . . . . . . . . . . . . . . . . . . . . 219<br />

N0690670 . . . . . . . . . . . . . . . . . . . . . . . . . . 222<br />

N0690671 . . . . . . . . . . . . . . . . . . . . . . . . . . 222<br />

N0690672 . . . . . . . . . . . . . . . . . . . . . . . . . . 219<br />

N0690673 . . . . . . . . . . . . . . . . . . . . . . . . . . 224<br />

N0690676 . . . . . . . . . . . . . . . . . . . . . . . . . . 223<br />

N0690677 . . . . . . . . . . . . . . . . . . . . . . . . . . 226<br />

N0690712 . . . . . . . . . . . . . . . . . . . . . . . . . . 227<br />

N0690720 . . . . . . . . . . . . . . . . . . . . . . . . . . 226<br />

N0690769 . . . . . . . . . . . . . . . . . . . . . . 220, 228<br />

N0690770 . . . . . . . . . . . . . . . . . . . . . . . . . . 228<br />

N0690772 . . . . . . . . . . . . . . . . . . . . . . . . . . 219<br />

N0690780 . . . . . . . . . . . . . . . . . . . . . . 220, 229<br />

N0690812 . . . . . . . . . . . . . . . . . . . . . . . . . . 227<br />

N0691182 . . . . . . . . . . . . . . . . . . . . . . . . . . 219<br />

N0691578 . . . . . . . . . . . . . . . . . . . . . . . . . . 217<br />

N0691579 . . . . . . . . . . . . . . . . . . . . . . . . . . 235<br />

N0691580 . . . . . . . . . . . . . . . . . . . . . . . . . . 233<br />

N0691581 . . . . . . . . . . . . . . . . . . . . . . . . . . 233<br />

N0691595 . . . . . . . . . . . . . . . . . . . . . . . . . . 224<br />

N0691662 . . . . . . . . . . . . . . . . . . . . . . 227, 229<br />

N0691664 . . . . . . . . . . . . . . . . . . . . . . . . . . 227<br />

N0691689 . . . . . . . . . . . . . . . . . . . . . . . . . . 219<br />

N0691702 . . . . . . . . . . . . . . . . . . . . . . . . . . 198<br />

N0691709 . . . . . . . . . . . . . . . . . . . . . . 199, 221<br />

N0691710 . . . . . . . . . . . . . . . . . . . . . . 199, 221<br />

N0691883 . . . . . . . . . . . . . . . . . . . . . . . . . . 217<br />

N0691884 . . . . . . . . . . . . . . . . . . . . . . . . . . 217<br />

N0695214 . . . . . . . . . . . . . . . . . . . . . . 220, 229<br />

N0695219 . . . . . . . . . . . . . . . . . . . . . . . . . . 219<br />

N0695220 . . . . . . . . . . . . . . . . . . . . . . . . . . 229<br />

N0695222 . . . . . . . . . . . . . . . . . . . . . . 226, 229<br />

N0695225 . . . . . . . . . . . . . . . . . . . . . . . . . . 229<br />

N0695233 . . . . . . . . . . . . . . . . . . . . . . . . . . 219<br />

N0695238 . . . . . . . . . . . . . . . . . . . . . . . . . . 229<br />

N0695295 . . . . . . . . . . . . . . . . . . . . . . . . . . 227<br />

N0695362 . . . . . . . . . . . . . . . . . . 220, 229-230<br />

N0695367 . . . . . . . . . . . . . . . . . . . . . . . . . . 230<br />

N0695368 . . . . . . . . . . . . . . . . . . . . . . . . . . 226<br />

N0695379 . . . . . . . . . . . . . . . . . . . . . . 227, 229<br />

N0695381 . . . . . . . . . . . . . . . . . . . . . . . . . . 230<br />

N0695400 . . . . . . . . . . . . . . . . . . 220, 229-230<br />

N0695414 . . . . . . . . . . . . . . . . . . . . . . . . . . 226<br />

N0695426 . . . . . . . . . . . . . . . . . . . . . . . . . . 226<br />

N0695433 . . . . . . . . . . . . . . . . . . . . . . . . . . 226<br />

N0695441 . . . . . . . . . . . . . . . . . . . . . . . . . . 220<br />

N0695442 . . . . . . . . . . . . . . . . . . . . . . . . . . 220<br />

N0695448 . . . . . . . . . . . . . . . . . . . . . . . . . . 220<br />

N0695449 . . . . . . . . . . . . . . . . . . . . . . . . . . 220<br />

N0695456 . . . . . . . . . . . . . . . . . . . . . . . . . . 227<br />

N0695460 . . . . . . . . . . . . . . . . . . . . . . 220, 226<br />

N0695461 . . . . . . . . . . . . . . . . . . . . . . . . . . 220<br />

N0695468 . . . . . . . . . . . . . . . . . . . . . . . . . . 216<br />

N0695469 . . . . . . . . . . . . . . . . . . . . . . . . . . 216<br />

N0695470 . . . . . . . . . . . . . . . . . . . . . . . . . . 216<br />

N0695471 . . . . . . . . . . . . . . . . . . . . . . . . . . 216<br />

N0695472 . . . . . . . . . . . . . . . . . . . . . . . . . . 216<br />

N0695473 . . . . . . . . . . . . . . . . . . . . . . . . . . 216<br />

N0695474 . . . . . . . . . . . . . . . . . . . . . . . . . . 216<br />

N0695475 . . . . . . . . . . . . . . . . . . . . . . . . . . 216<br />

N0695477 . . . . . . . . . . . . . . . . . . . . . . . . . . 205<br />

N0695494 . . . . . . . . . . . . . . . . . . . . . . . . . . 220<br />

N0695495 . . . . . . . . . . . . . . . . . . . . . . 195, 220<br />

N0770198 . . . . . . . . . . . . . . . . . . . . . . . . . . 216<br />

N0770322 . . . . . . . . . . . . . . . . . . . . . . . . . . 219<br />

N0770338 . . . . . . . . . . . . . . . . . . . . . . . . . . 227<br />

N0770343 . . . . . . . . . . . . . . . . . . . . . . . . . . 227<br />

N0770344 . . . . . . . . . . . . . . . . . . . . . . . . . . 227<br />

N0770357 . . . . . . . . . . . . . . . . . . . . . . . . . . 226<br />

N0770358 . . . . . . . . . . . . . . . . . . . . . . . . . . 222<br />

N0770434 . . . . . . . . . . . . . . . . . . . . . . . . . . 217<br />

N0770437 . . . . . . . . . . . . . . . . . . . . . . . . . . 228<br />

N0770438 . . . . . . . . . . . . . . . . . . . . . . . . . . 220<br />

N0770546 . . . . . . . . . . . . . . . . . . . . . . . . . . 223<br />

N0770600 . . . . . . . . . . . . . . . . . . . . . . . . . . 227<br />

N0770603 . . . . . . . . . . . . . . . . . . . . . . . . . . 220<br />

N0770606 . . . . . . . . . . . . . . . . . . . . . . . . . . 227<br />

N0770607 . . . . . . . . . . . . . . . . . . . . . . . . . . 227<br />

N0770608 . . . . . . . . . . . . . . . . . . . . . . . . . . 228<br />

N0770609 . . . . . . . . . . . . . . . . . . . . . . . . . . 227<br />

N0770910 . . . . . . . . . . . . . . . . . . . . . . . . . . 228<br />

N0770911 . . . . . . . . . . . . . . . . . . . . . . . . . . 228<br />

N0771116 . . . . . . . . . . . . . . . . . . . . . . . . . . 219<br />

N0771500 . . . . . . . . . . . . . . . . . . . . . . . . . . 227<br />

N0771501 . . . . . . . . . . . . . . . . . . . . . . . . . . 225<br />

N0771526 . . . . . . . . . . . . . . . . . . . . . . . . . . 220<br />

N0771527 . . . . . . . . . . . . . . . . . . . . . . . . . . 220<br />

N0771529 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9<br />

N0771531 . . . . . . . . . . . . . . . . . . . . . . . . . . 220<br />

N0771536 . . . . . . . . . . . . . . . . . . . . . . . . . . 219<br />

N0771550 . . . . . . . . . . . . . . . . . . . . . . . . . . 225<br />

N0772025 . . . . . . . . . . . . . . . . . . . . . . 189, 217<br />

N0772026 . . . . . . . . . . . . . . . . . . . . . . 189, 217<br />

Part No. Page Part No. Page Part No. Page<br />

See page 4 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

See page 2 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong>


Index Part Number N0775014 – N2910344<br />

Index<br />

Part Number<br />

416<br />

N0775014 . . . . . . . . . . . . . . . . . . . . . . . . . . 220<br />

N0775177 . . . . . . . . . . . . . . . . . . . . . . . . . . 220<br />

N0775220 . . . . . . . . . . . . . . . . . . . . . . . . . . 216<br />

N0775223 . . . . . . . . . . . . . . . . . . . . . . . . . . 220<br />

N0775224 . . . . . . . . . . . . . . . . . . . . . . . . . . 220<br />

N0775225 . . . . . . . . . . . . . . . . . . . . . . . . . . 220<br />

N0775226 . . . . . . . . . . . . . . . . . . . . . . . . . . 220<br />

N0775227 . . . . . . . . . . . . . . . . . . . . . . . . . . 220<br />

N0775228 . . . . . . . . . . . . . . . . . . . . . . . . . . 220<br />

N0775247 . . . . . . . . . . . . . . . . . . . . . . . . . . 220<br />

N0775289 . . . . . . . . . . . . . . . . . . . . . . . . . . 227<br />

N0775297 . . . . . . . . . . . . . . . . . . . . . . . . . . 228<br />

N0775300 . . . . . . . . . . . . . . . . . . . . . . . . . . 219<br />

N0775330 . . . . . . . . . . . . . . . . . . . . . . . . . . 222<br />

N0775331 . . . . . . . . . . . . . . . . . . . . . . . . . . 218<br />

N0775340 . . . . . . . . . . . . . . . . . . . . . . 197, 222<br />

N0775341 . . . . . . . . . . . . . . . . . . . . . . 197, 222<br />

N0775342 . . . . . . . . . . . . . . . . . . . . . . 197, 222<br />

N0775343 . . . . . . . . . . . . . . . . . . . . . . 197, 222<br />

N0775344 . . . . . . . . . . . . . . . . . . . . . . 197, 222<br />

N0775345 . . . . . . . . . . . . . . . . . . . . . . . . . . 222<br />

N0775346 . . . . . . . . . . . . . . . . . . . . . . . . . . 221<br />

N0775347 . . . . . . . . . . . . . . . . . . . . . . . . . . 221<br />

N0775348 . . . . . . . . . . . . . . . . . . . . . . . . . . 221<br />

N0775349 . . . . . . . . . . . . . . . . . . . . . . . . . . 221<br />

N0775350 . . . . . . . . . . . . . . . . . . . . . . 203, 225<br />

N0775351 . . . . . . . . . . . . . . . . . . . . . . . . . . 225<br />

N0775352 . . . . . . . . . . . . . . . . . . . . . . . . . . 225<br />

N0775353 . . . . . . . . . . . . . . . . . . . . . . . . . . 202<br />

N0775354 . . . . . . . . . . . . . . . . . . . . . . . . . . 203<br />

N0775355 . . . . . . . . . . . . . . . . . . . . . . . . . . 225<br />

N0775356 . . . . . . . . . . . . . . . . . . . . . . . . . . 225<br />

N0775357 . . . . . . . . . . . . . . . . . . . . . . . . . . 225<br />

N0775358 . . . . . . . . . . . . . . . . . . . . . . . . . . 219<br />

N0776052 . . . . . . . . . . . . . . . . . . . . . . . . . . 225<br />

N0776053 . . . . . . . . . . . . . . . . . . . . . . . . . . 225<br />

N0776099 . . . . . . . . . . . . . . . . . . . . . . . . . . 217<br />

N0911028 . . . . . . . . . . . . . . . . . . . . . . . . . . 323<br />

N0911038 . . . . . . . . . . . . . . . . . . . . . . . . . . 323<br />

N0911041 . . . . . . . . . . . . . . . . . . . . . . . . . . 325<br />

N1010047 . . . . . . . . . . . . . . . . . . . . . . . . . . 143<br />

N1010048 . . . . . . . . . . . . . . . . . . . . . . . . . . 144<br />

N1010050 . . . . . . . . . . . . . . . . . . . . . . . . . . 143<br />

N1010070 . . . . . . . . . . . . . . . . . . . . . . . . . . 148<br />

N1010200 . . . . . . . . . . . . . . . . . . . . . . . . . . . 71<br />

N1010202 . . . . . . . . . . . . . . . . . . . . . . . . . . . 71<br />

N1010215 . . . . . . . . . . . . . . . . . . . . . . . . 13, 18<br />

N1010230 . . . . . . . . . . . . . . . . . . . . . . . . . . . 71<br />

N1010504 . . . . . . . . . . . . . . . . . . . . . . . . . . 396<br />

N1010520 . . . . . . . . . . . . . . . . . . . . . . . . . . 382<br />

N1010539 . . . . . . . . . . . . . . . . . . . . . . . . . . 396<br />

N1010540 . . . . . . . . . . . . . . . . . . . . . . . . . . 396<br />

N1010565 . . . . . . . . . . . . . . . . . . . . . . . . . . 385<br />

N1010566 . . . . . . . . . . . . . . . . . . . . . . . . . . 385<br />

N1010567 . . . . . . . . . . . . . . . . . . . . . . . . . . 387<br />

N1010568 . . . . . . . . . . . . . . . . . . . . . . . . . . 387<br />

N1010569 . . . . . . . . . . . . . . . . . . . . . . . . . . 387<br />

N1011206 . . . . . . . . . . . . . . . . . . . . . . . . . . 147<br />

N1011210 . . . . . . . . . . . . . . . . . . . . . . . . . . 144<br />

N1011445 . . . . . . . . . . . . . . . . . . 144, 150, 157<br />

N1011446 . . . . . . . . . . 144, 150, 155, 157-158<br />

N1011447 . . . . . . . . . . . . . . . . . . 144, 155, 158<br />

N1015158 . . . . . . . . . . . . . . . . . . . . . . . . . . 386<br />

N1016001 . . . . . . . . . . . . . . . . . . . . . . . . . . 384<br />

N1016008 . . . . . . . . . . . . . . . . . . . . . . . . . . 384<br />

N1016015 . . . . . . . . . . . . . . . . . . . . . . . . . . 384<br />

N1016030 . . . . . . . . . . . . . . . . . . . . . . . . . . 384<br />

N1016045 . . . . . . . . . . . . . . . . . . . . . . . . . . 384<br />

N1016060 . . . . . . . . . . . . . . . . . . . . . . . . . . 384<br />

N1016070 . . . . . . . . . . . . . . . . . . . . . . . . . . 380<br />

N1016071 . . . . . . . . . . . . . . . . . . . . . . . . . . 380<br />

N1016072 . . . . . . . . . . . . . . . . . . . . . . . . . . 380<br />

N1016073 . . . . . . . . . . . . . . . . . . . . . . . . . . 380<br />

N1016074 . . . . . . . . . . . . . . . . . . . . . . . . . . 380<br />

N1870151 . . . . . . . . . . . . . . . . . . . . . . . . . . 253<br />

N1870184 . . . . . . . . . . . . . . . . . . . . . . . . . . 254<br />

N1870185 . . . . . . . . . . . . . . . . . . . . . . . . . . 254<br />

N1870188 . . . . . . . . . . . . . . . . . . . . . . . . . . 254<br />

N1873124 . . . . . . . . . . . . . . . . . . . . . . . . . . 254<br />

N2010381 . . . . . . . . . . . . . . . . . . . . . . . . . . . 13<br />

N2011074 . . . . . . . . . . . . . . . . . . . . . . . . . . . 13<br />

N2350014 . . . . . . . . . . . . . . . . . . . . . . . . . . 314<br />

N2350211 . . . . . . . . . . . . . . . . . . . . . . . . . . 314<br />

N2351285 . . . . . . . . . . . . . . . . . . . . . . . . . . 314<br />

N2410021 . . . . . . . . . . . . . . . . . . . . . . . . . . . 77<br />

N2410022 . . . . . . . . . . . . . . . . . . . . . . . . . . . 77<br />

N2410092 . . . . . . . . . . . . . . . . . . . . . . . . . . . 78<br />

N2410141 . . . . . . . . . . . . . . . . . . . . . . . . . . . 77<br />

N2410145 . . . . . . . . . . . . . . . . . . . . . . . . 76, 78<br />

N2410146 . . . . . . . . . . . . . . . . . . . . . . . . . . . 80<br />

N2410147 . . . . . . . . . . . . . . . . . . . . . . . 77, 355<br />

N2410153 . . . . . . . . . . . . . . . . . . . . . . . . . . . 79<br />

N2410154 . . . . . . . . . . . . . . . . . . . . . . . . . . . 79<br />

N2410155 . . . . . . . . . . . . . . . . . . . . . . . . . . . 80<br />

N2410157 . . . . . . . . . . . . . . . . . . . . . . . . . . . 78<br />

N2410164 . . . . . . . . . . . . . . . . . . . . . . . . . . . 78<br />

N2410165 . . . . . . . . . . . . . . . . . . . . . . . . . . . 78<br />

N2410166 . . . . . . . . . . . . . . . . . . . . . . . . . . . 78<br />

N2410170 . . . . . . . . . . . . . . . . . . . . . . . 77, 354<br />

N2410172 . . . . . . . . . . . . . . . . . . . . . . . . . . . 77<br />

N2410173 . . . . . . . . . . . . . . . . . . . . . . . . . . . 77<br />

N2410174 . . . . . . . . . . . . . . . . . . . . . . . . . . . 77<br />

N2410177 . . . . . . . . . . . . . . . . . . . . . . . . . . . 79<br />

N2410188 . . . . . . . . . . . . . . . . . . . . . . . . . . . 78<br />

N2410189 . . . . . . . . . . . . . . . . . . . . . . . . . . . 76<br />

N2410191 . . . . . . . . . . . . . . . . . . . . . . . . . . . 78<br />

N2410212 . . . . . . . . . . . . . . . . . . . . . . . . . . . 79<br />

N2410237 . . . . . . . . . . . . . . . . . . . . . . . . . . . 81<br />

N2410244 . . . . . . . . . . . . . . . . . . . . . . . . . . . 80<br />

N2410248 . . . . . . . . . . . . . . . . . . . . . . . . . . . 77<br />

N2410265 . . . . . . . . . . . . . . . . . . . . . . . . . . . 76<br />

N2410277 . . . . . . . . . . . . . . . . . . . . . . . . . . . 78<br />

N2410278 . . . . . . . . . . . . . . . . . . . . . . . . . . . 78<br />

N2410315 . . . . . . . . . . . . . . . . . . . . . . . . . . . 81<br />

N2410320 . . . . . . . . . . . . . . . . . . . . . . . . . . . 80<br />

N2410324 . . . . . . . . . . . . . . . . . . . . . . . . 76, 80<br />

N2410325 . . . . . . . . . . . . . . . . . . . . . . . . . . . 80<br />

N2410327 . . . . . . . . . . . . . . . . . . . . . . . . . . . 77<br />

N2410330 . . . . . . . . . . . . . . . . . . . . . . . . . . . 79<br />

N2410331 . . . . . . . . . . . . . . . . . . . . . . . . . . . 78<br />

N2410332 . . . . . . . . . . . . . . . . . . . . . . . . . . . 78<br />

N2410360 . . . . . . . . . . . . . . . . . . . . . . . . . . . 77<br />

N2410361 . . . . . . . . . . . . . . . . . . . . . . . . . . . 77<br />

N2410365 . . . . . . . . . . . . . . . . . . . . . . . . . . . 77<br />

N2410501 . . . . . . . . . . . . . . . . . . . . . . . . 76, 80<br />

N2410502 . . . . . . . . . . . . . . . . . . . . . . . . . . . 77<br />

N2410503 . . . . . . . . . . . . . . . . . . . . . . . . . . . 77<br />

N2410506 . . . . . . . . . . . . . . . . . . . . . . . . . . . 76<br />

N2410507 . . . . . . . . . . . . . . . . . . . . . . . . . . . 76<br />

N2410513 . . . . . . . . . . . . . . . . . . . . . . . . . . . 76<br />

N2410518 . . . . . . . . . . . . . . . . . . . . . . . . . . . 78<br />

N2410680 . . . . . . . . . . . . . . . . . . . . . . . . . . . 78<br />

N2410681 . . . . . . . . . . . . . . . . . . . . . . . . . . . 78<br />

N2410682 . . . . . . . . . . . . . . . . . . . . . . . . 76, 78<br />

N2410683 . . . . . . . . . . . . . . . . . . . . . . . . 76, 78<br />

N2410684 . . . . . . . . . . . . . . . . . . . . . . . . . . . 78<br />

N2411019 . . . . . . . . . . . . . . . . . . . . . . . . . . . 82<br />

N2411087 . . . . . . . . . . . . . . . . . . . . . . . . . . . 83<br />

N2411088 . . . . . . . . . . . . . . . . . . . . . . . . . . . 83<br />

N2411117 . . . . . . . . . . . . . . . . . . . . . . . . . . . 81<br />

N2411118 . . . . . . . . . . . . . . . . . . . . . . . . . . . 81<br />

N2411144 . . . . . . . . . . . . . . . . . . . . . . . . . . . 82<br />

N2411235 . . . . . . . . . . . . . . . . . . . . . . . . 76, 79<br />

N2411255 . . . . . . . . . . . . . . . . . . . . . . . . . . . 80<br />

N2411257 . . . . . . . . . . . . . . . . . . . . . . . . . . . 83<br />

N2411264 . . . . . . . . . . . . . . . . . . . . . . . . . . . 79<br />

N2411267 . . . . . . . . . . . . . . . . . . . . . . . . . . . 80<br />

N2411273 . . . . . . . . . . . . . . . . . . . . . . . . 76, 78<br />

N2411274 . . . . . . . . . . . . . . . . . . . . . . . . . . . 82<br />

N2411291 . . . . . . . . . . . . . . . . . . . . . . . . . . . 79<br />

N2411300 . . . . . . . . . . . . . . . . . . . . . . . . 76, 79<br />

N2411333 . . . . . . . . . . . . . . . . . . . . . . . . 76, 78<br />

N2411335 . . . . . . . . . . . . . . . . . . . . . . . . . . . 79<br />

N2411341 . . . . . . . . . . . . . . . . . . . . . . . . . . . 81<br />

N2411342 . . . . . . . . . . . . . . . . . . . . . . . . . . . 81<br />

N2411359 . . . . . . . . . . . . . . . . . . . . . 76, 79, 82<br />

N2411362 . . . . . . . . . . . . . . . . . . . . . . . . . . . 80<br />

N2411363 . . . . . . . . . . . . . . . . . . . . . . . . . . . 80<br />

N2411364 . . . . . . . . . . . . . . . . . . . . . . . . . . . 80<br />

N2411374 . . . . . . . . . . . . . . . . . . . . . . . . . . . 83<br />

N2411401 . . . . . . . . . . . . . . . . . . . . . . . . 76, 79<br />

N2411487 . . . . . . . . . . . . . . . . . . . . . . . . . . . 79<br />

N2411514 . . . . . . . . . . . . . . . . . . . . . . . . . . . 79<br />

N2411527 . . . . . . . . . . . . . . . . . . . . . . . . . . . 78<br />

N2420212 . . . . . . . . . . . . . . . . . . . . . . . . . . . 76<br />

N2420214 . . . . . . . . . . . . . . . . . . . . . . . . . . . 81<br />

N2421070 . . . . . . . . . . . . . . . . . . . . . . . . . . . 79<br />

N2580003 . . . . . . . . . . . . . . . . . . . . . . . . . . 285<br />

N2580012 . . . . . . . . . . . . . . . . . . . . . . . . . . 285<br />

N2580013 . . . . . . . . . . . . . . . . . . . . . . . . . . 285<br />

N2580020 . . . . . . . . . . . . . . . . . . . . . . . . . . 285<br />

N2580021 . . . . . . . . . . . . . . . . . . . . . . . . . . 285<br />

N2580022 . . . . . . . . . . . . . . . . . . . . . . . . . . 285<br />

N2580030 . . . . . . . . . . . . . . . . . . . . . . . . . . 293<br />

N2580042 . . . . . . . . . . . . . . . . . . . . . . . . . . 285<br />

N2600070 . . . . . . . . . . . . . . . . . . . . . . . . . . 322<br />

N2600089 . . . . . . . . . . . . . . . . . . . . . . 273, 322<br />

N2600104 . . . . . . . . . . . . . . . . . . . . . . 319-320<br />

N2600124 . . . . . . . . . . . . . . . . . . . . . . 319-320<br />

N2600192 . . . . . . . . . . . . . . . . . . . . . . 319-320<br />

N2600226 . . . . . . . . . . . . . . . . . . . . . . 319-320<br />

N2600259 . . . . . . . . . . . . . . . . . . . . . . . . . . 322<br />

N2600284 . . . . . . . . . . . . . . . . . . . . . . . . . . 318<br />

N2600313 . . . . . . . . . . . . . . . . . . . . . . . . . . 321<br />

N2600456 . . . . . . . . . . . . . . . . . . . . . . . . . . 318<br />

N2600457 . . . . . . . . . . . . . . . . . . . . . . . . . . 318<br />

N2600458 . . . . . . . . . . . . . . . . . . . . . . . . . . 318<br />

N2600459 . . . . . . . . . . . . . . . . . . . . . . . . . . 318<br />

N2600491 . . . . . . . . . . . . . . . . . . . . . . . . . . 318<br />

N2600495 . . . . . . . . . . . . . . . . . . . . . . . . . . 318<br />

N2600496 . . . . . . . . . . . . . . . . . . . . . . . . . . 318<br />

N2600497 . . . . . . . . . . . . . . . . . . . . . . . . . . 318<br />

N2600498 . . . . . . . . . . . . . . . . . . . . . . . . . . 318<br />

N2600499 . . . . . . . . . . . . . . . . . . . . . . . . . . 318<br />

N2600505 . . . . . . . . . . . . . . . . . . . . . . . . . . 318<br />

N2600506 . . . . . . . . . . . . . . . . . . . . . . . . . . 318<br />

N2600570 . . . . . . . . . . . . . . . . . . . . . . . . . . 318<br />

N2600571 . . . . . . . . . . . . . . . . . . . . . . . . . . 318<br />

N2601149 . . . . . . . . . . . . . . . . . . . . . . . . . . 323<br />

N2601174 . . . . . . . . . . . . . . . . . . . . . . 319-320<br />

N2601189 . . . . . . . . . . . . . . . . . . . . . . . . . . 318<br />

N2601262 . . . . . . . . . . . . . . . . . . . . . . . . . . 322<br />

N2601295 . . . . . . . . . . . . . . . . . . . . . . . . . . 321<br />

N2601313 . . . . . . . . . . . . . . . . . . . . . . . . . . 321<br />

N2601316 . . . . . . . . . . . . . . . . . . . . . . . . . . 321<br />

N2601346 . . . . . . . . . . . . . . . . . . . . . . . . . . 323<br />

N2601477 . . . . . . . . . . . . . . . . . . . . . . . . . . 322<br />

N2601503 . . . . . . . . . . . . . . . . . . . . . . . . . . 321<br />

N2601579 . . . . . . . . . . . . . . . . . . . . . . . . . . 317<br />

N2601580 . . . . . . . . . . . . . . . . . . . . . . . . . . 317<br />

N2601581 . . . . . . . . . . . . . . . . . . . . . . . . . . 317<br />

N2601585 . . . . . . . . . . . . . . . . . . . . . . . . . . 317<br />

N2910035 . . . . . . . . . . . . . . . . . . . . . . . . . . 321<br />

N2910342 . . . . . . . . . . . . . . . . . . . . . . . . . . 321<br />

N2910343 . . . . . . . . . . . . . . . . . . . . . . . . . . 321<br />

N2910344 . . . . . . . . . . . . . . . . . . . . . . . . . . 321<br />

Part No. Page Part No. Page Part No. Page


N2910345 – N3050411 Part Number Index<br />

Index<br />

Part Number<br />

417<br />

N2910345 . . . . . . . . . . . . . . . . . . . . . . . . . . 321<br />

N2910346 . . . . . . . . . . . . . . . . . . . . . . . . . . 321<br />

N2910349 . . . . . . . . . . . . . . . . . . . . . . . . . . 321<br />

N2910383 . . . . . . . . . . . . . . . . . . . . . . . . . . 321<br />

N2910384 . . . . . . . . . . . . . . . . . . . . . . . . . . 321<br />

N2910385 . . . . . . . . . . . . . . . . . . . . . . . . . . 321<br />

N2910511 . . . . . . . . . . . . . . . . . . . . . . 319-320<br />

N2910512 . . . . . . . . . . . . . . . . . . . . . . 319-320<br />

N2910520 . . . . . . . . . . . . . . . . . . . . . . . . . . 321<br />

N2910521 . . . . . . . . . . . . . . . . . . . . . . . . . . 321<br />

N2910522 . . . . . . . . . . . . . . . . . . . . . . . . . . 321<br />

N2910523 . . . . . . . . . . . . . . . . . . . . . . . . . . 321<br />

N2911170 . . . . . . . . . . . . . . . . . . . . . . . . . . 321<br />

N2911171 . . . . . . . . . . . . . . . . . . . . . . . . . . 321<br />

N2911172 . . . . . . . . . . . . . . . . . . . . . . . . . . 321<br />

N2911173 . . . . . . . . . . . . . . . . . . . . . . . . . . 321<br />

N2911174 . . . . . . . . . . . . . . . . . . . . . . . . . . 321<br />

N2911175 . . . . . . . . . . . . . . . . . . . . . . . . . . 321<br />

N2911176 . . . . . . . . . . . . . . . . . . . . . . . . . . 321<br />

N2911177 . . . . . . . . . . . . . . . . . . . . . . . . . . 321<br />

N2911178 . . . . . . . . . . . . . . . . . . . . . . . . . . 321<br />

N2915102 . . . . . . . . . . . . . . . . . . . . . . . . . . 321<br />

N2920117 . . . . . . . . . . . . . . . . . . . . . . . . . . 316<br />

N2920124 . . . . . . . . . . . . . . . . . . . . . . . . . . 316<br />

N2920125 . . . . . . . . . . . . . . . . . . . . . . . . . . 316<br />

N2920146 . . . . . . . . . . . . . . . . . . . . . . . . . . 316<br />

N2920149 . . . . . . . . . . . . . . . . . . . . . . . . . . 316<br />

N2922006 . . . . . . . . . . . . . . . . . . . . . . . . . . 315<br />

N2922010 . . . . . . . . . . . . . . . . . . . . . . . . . . 314<br />

N2922011 . . . . . . . . . . . . . . . . . . . . . . . . . . 314<br />

N2922028 . . . . . . . . . . . . . . . . . . . . . . . . . . 314<br />

N2922029 . . . . . . . . . . . . . . . . . . . . . . . . . . 314<br />

N2922030 . . . . . . . . . . . . . . . . . . . . . . . . . . 314<br />

N2922046 . . . . . . . . . . . . . . . . . . . . . . . . . . 314<br />

N2922082 . . . . . . . . . . . . . . . . . . . . . . . . . . 315<br />

N2930023 . . . . . . . . . . . . . . . . . . . . . . . . . . 273<br />

N2930024 . . . . . . . . . . . . . . . . . . . . . . . . . . 273<br />

N2930035 . . . . . . . . . . . . . . . . . . . . . . 208, 270<br />

N2930036 . . . . . . . . . . . . . . . . . . . . . . 208, 270<br />

N2930037 . . . . . . . . . . . . . . . . . . . . . . . . . . 270<br />

N2930038 . . . . . . . . . . . . . . . . . . . . . . . . . . 270<br />

N2930040 . . . . . . . . . . . . . . . . . . . . . . . . . . 270<br />

N2930041 . . . . . . . . . . . . . . . . . . . . . . . . . . 270<br />

N2930042 . . . . . . . . . . . . . . . . . . . . . . . . . . 270<br />

N2930043 . . . . . . . . . . . . . . . . . . . . . . . . . . 270<br />

N2930044 . . . . . . . . . . . . . . . . . . . . . . . . . . 270<br />

N2930146 . . . . . . . . . . . . . . . . . . . . . . . . . . 270<br />

N2930147 . . . . . . . . . . . . . . . . . . . . . . . . . . 270<br />

N2930311 . . . . . . . . . . . . . . . . . . . . . . . . . . 273<br />

N2930312 . . . . . . . . . . . . . . . . . . . . . . . . . . 273<br />

N2930313 . . . . . . . . . . . . . . . . . . . . . . . . . . 273<br />

N2930314 . . . . . . . . . . . . . . . . . . . . . . . . . . 270<br />

N2930340 . . . . . . . . . . . . . . . . . . . . . . . . . . 273<br />

N2930341 . . . . . . . . . . . . . . . . . . . . . . . . . . 273<br />

N2930343 . . . . . . . . . . . . . . . . . . . . . . . . . . 331<br />

N2931012 . . . . . . . . . . . . . . . . . . . . . . . . . . 273<br />

N2931054 . . . . . . . . . . . . . . . . . . . . . . . . . . 325<br />

N2931064 . . . . . . . . . . . . . . . . . . . . . . . . . . 273<br />

N2931081 . . . . . . . . . . . . . . . . . . . . . . . . . . 273<br />

N2931097 . . . . . . . . . . . . . . . . . . . . . . . . . . 270<br />

N3050102 . . . . . . . . . . . . . . . . . . . . . . . . . . . 41<br />

N3050103 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />

N3050105 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />

N3050107 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />

N3050108 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />

N3050109 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />

N3050110 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />

N3050111 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />

N3050114 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />

N3050115 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />

N3050118 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />

N3050119 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />

N3050121 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />

N3050122 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />

N3050123 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />

N3050124 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />

N3050126 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />

N3050128 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />

N3050129 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />

N3050130 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />

N3050133 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />

N3050134 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />

N3050135 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />

N3050137 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />

N3050138 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />

N3050139 . . . . . . . . . . . . . . . . . . . . . . . . . . . 41<br />

N3050141 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />

N3050142 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />

N3050144 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />

N3050145 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />

N3050146 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />

N3050148 . . . . . . . . . . . . . . . . . . . . . . . . . . . 41<br />

N3050149 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />

N3050150 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />

N3050152 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />

N3050155 . . . . . . . . . . . . . . . . . . . . . . . . . . . 41<br />

N3050157 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />

N3050158 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />

N3050161 . . . . . . . . . . . . . . . . . . . . . . . . . . . 41<br />

N3050162 . . . . . . . . . . . . . . . . . . . . . . . . . . . 41<br />

N3050165 . . . . . . . . . . . . . . . . . . . . . . . . . . . 41<br />

N3050166 . . . . . . . . . . . . . . . . . . . . . . . . . . . 41<br />

N3050168 . . . . . . . . . . . . . . . . . . . . . . . . . . . 41<br />

N3050170 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />

N3050171 . . . . . . . . . . . . . . . . . . . . . . . . . . . 41<br />

N3050172 . . . . . . . . . . . . . . . . . . . . . . . . . . . 41<br />

N3050173 . . . . . . . . . . . . . . . . . . . . . . . . . . . 41<br />

N3050174 . . . . . . . . . . . . . . . . . . . . . . . . . . . 41<br />

N3050175 . . . . . . . . . . . . . . . . . . . . . . . . . . . 41<br />

N3050176 . . . . . . . . . . . . . . . . . . . . . . . . . . . 41<br />

N3050177 . . . . . . . . . . . . . . . . . . . . . . . . . . . 41<br />

N3050178 . . . . . . . . . . . . . . . . . . . . . . . . . . . 41<br />

N3050180 . . . . . . . . . . . . . . . . . . . . . . . . . . . 41<br />

N3050182 . . . . . . . . . . . . . . . . . . . . . . . . . . . 41<br />

N3050183 . . . . . . . . . . . . . . . . . . . . . . . . . . . 41<br />

N3050184 . . . . . . . . . . . . . . . . . . . . . . . . . . . 41<br />

N3050186 . . . . . . . . . . . . . . . . . . . . . . . . . . . 41<br />

N3050187 . . . . . . . . . . . . . . . . . . . . . . . . . . . 41<br />

N3050189 . . . . . . . . . . . . . . . . . . . . . . . . . . . 41<br />

N3050190 . . . . . . . . . . . . . . . . . . . . . . . . . . . 41<br />

N3050191 . . . . . . . . . . . . . . . . . . . . . . . . . . . 41<br />

N3050192 . . . . . . . . . . . . . . . . . . . . . . . . . . . 41<br />

N3050196 . . . . . . . . . . . . . . . . . . . . . . . . . . . 44<br />

N3050197 . . . . . . . . . . . . . . . . . . . . . . . . . . . 44<br />

N3050198 . . . . . . . . . . . . . . . . . . . . . . . . . . . 44<br />

N3050201 . . . . . . . . . . . . . . . . . . . . . . . . . . . 42<br />

N3050202 . . . . . . . . . . . . . . . . . . . . . . . . . . . 42<br />

N3050203 . . . . . . . . . . . . . . . . . . . . . . . . . . . 42<br />

N3050204 . . . . . . . . . . . . . . . . . . . . . . . . . . . 42<br />

N3050205 . . . . . . . . . . . . . . . . . . . . . . . . . . . 42<br />

N3050206 . . . . . . . . . . . . . . . . . . . . . . . . . . . 42<br />

N3050207 . . . . . . . . . . . . . . . . . . . . . . . . . . . 42<br />

N3050208 . . . . . . . . . . . . . . . . . . . . . . . . . . . 42<br />

N3050209 . . . . . . . . . . . . . . . . . . . . . . . . . . . 42<br />

N3050210 . . . . . . . . . . . . . . . . . . . . . . . . . . . 42<br />

N3050211 . . . . . . . . . . . . . . . . . . . . . . . . . . . 42<br />

N3050212 . . . . . . . . . . . . . . . . . . . . . . . . . . . 42<br />

N3050213 . . . . . . . . . . . . . . . . . . . . . . . . . . . 42<br />

N3050214 . . . . . . . . . . . . . . . . . . . . . . . . . . . 42<br />

N3050215 . . . . . . . . . . . . . . . . . . . . . . . . . . . 42<br />

N3050216 . . . . . . . . . . . . . . . . . . . . . . . . . . . 42<br />

N3050217 . . . . . . . . . . . . . . . . . . . . . . . . . . . 42<br />

N3050218 . . . . . . . . . . . . . . . . . . . . . . . . . . . 42<br />

N3050302 . . . . . . . . . . . . . . . . . . . . . . . . . . . 41<br />

N3050303 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />

N3050305 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />

N3050307 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />

N3050308 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />

N3050309 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />

N3050310 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />

N3050311 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />

N3050314 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />

N3050315 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />

N3050318 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />

N3050319 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />

N3050321 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />

N3050322 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />

N3050323 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />

N3050324 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />

N3050326 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />

N3050328 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />

N3050329 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />

N3050330 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />

N3050333 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />

N3050334 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />

N3050335 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />

N3050337 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />

N3050338 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />

N3050339 . . . . . . . . . . . . . . . . . . . . . . . . . . . 41<br />

N3050341 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />

N3050342 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />

N3050344 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />

N3050345 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />

N3050346 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />

N3050348 . . . . . . . . . . . . . . . . . . . . . . . . . . . 41<br />

N3050349 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />

N3050350 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />

N3050352 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />

N3050355 . . . . . . . . . . . . . . . . . . . . . . . . . . . 41<br />

N3050357 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />

N3050358 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />

N3050361 . . . . . . . . . . . . . . . . . . . . . . . . . . . 41<br />

N3050362 . . . . . . . . . . . . . . . . . . . . . . . . . . . 41<br />

N3050365 . . . . . . . . . . . . . . . . . . . . . . . . . . . 41<br />

N3050366 . . . . . . . . . . . . . . . . . . . . . . . . . . . 41<br />

N3050368 . . . . . . . . . . . . . . . . . . . . . . . . . . . 41<br />

N3050370 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />

N3050371 . . . . . . . . . . . . . . . . . . . . . . . . . . . 41<br />

N3050372 . . . . . . . . . . . . . . . . . . . . . . . . . . . 41<br />

N3050373 . . . . . . . . . . . . . . . . . . . . . . . . . . . 41<br />

N3050374 . . . . . . . . . . . . . . . . . . . . . . . . . . . 41<br />

N3050375 . . . . . . . . . . . . . . . . . . . . . . . . . . . 41<br />

N3050376 . . . . . . . . . . . . . . . . . . . . . . . . . . . 41<br />

N3050377 . . . . . . . . . . . . . . . . . . . . . . . . . . . 41<br />

N3050378 . . . . . . . . . . . . . . . . . . . . . . . . . . . 41<br />

N3050380 . . . . . . . . . . . . . . . . . . . . . . . . . . . 41<br />

N3050382 . . . . . . . . . . . . . . . . . . . . . . . . . . . 41<br />

N3050383 . . . . . . . . . . . . . . . . . . . . . . . . . . . 41<br />

N3050384 . . . . . . . . . . . . . . . . . . . . . . . . . . . 41<br />

N3050386 . . . . . . . . . . . . . . . . . . . . . . . . . . . 41<br />

N3050387 . . . . . . . . . . . . . . . . . . . . . . . . . . . 41<br />

N3050389 . . . . . . . . . . . . . . . . . . . . . . . . . . . 41<br />

N3050390 . . . . . . . . . . . . . . . . . . . . . . . . . . . 41<br />

N3050391 . . . . . . . . . . . . . . . . . . . . . . . . . . . 41<br />

N3050392 . . . . . . . . . . . . . . . . . . . . . . . . . . . 41<br />

N3050401 . . . . . . . . . . . . . . . . . . . . . . . . . . . 42<br />

N3050402 . . . . . . . . . . . . . . . . . . . . . . . . . . . 42<br />

N3050403 . . . . . . . . . . . . . . . . . . . . . . . . . . . 42<br />

N3050404 . . . . . . . . . . . . . . . . . . . . . . . . . . . 42<br />

N3050405 . . . . . . . . . . . . . . . . . . . . . . . . . . . 42<br />

N3050406 . . . . . . . . . . . . . . . . . . . . . . . . . . . 42<br />

N3050407 . . . . . . . . . . . . . . . . . . . . . . . . . . . 42<br />

N3050408 . . . . . . . . . . . . . . . . . . . . . . . . . . . 42<br />

N3050409 . . . . . . . . . . . . . . . . . . . . . . . . . . . 42<br />

N3050410 . . . . . . . . . . . . . . . . . . . . . . . . . . . 42<br />

N3050411 . . . . . . . . . . . . . . . . . . . . . . . . . . . 42<br />

Part No. Page Part No. Page Part No. Page<br />

See page 4 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

See page 2 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong>


Index Part Number N3050412 – N5150130<br />

Index<br />

Part Number<br />

418<br />

N3050412 . . . . . . . . . . . . . . . . . . . . . . . . . . . 42<br />

N3050413 . . . . . . . . . . . . . . . . . . . . . . . . . . . 42<br />

N3050414 . . . . . . . . . . . . . . . . . . . . . . . . . . . 42<br />

N3050415 . . . . . . . . . . . . . . . . . . . . . . . . . . . 42<br />

N3050416 . . . . . . . . . . . . . . . . . . . . . . . . . . . 42<br />

N3050417 . . . . . . . . . . . . . . . . . . . . . . . . . . . 42<br />

N3050418 . . . . . . . . . . . . . . . . . . . . . . . . . . . 42<br />

N3050605 . . . . . . . . . . . . . . . . . . . . . . . . . . . 47<br />

N3050611 . . . . . . . . . . . . . . . . . . . . . . . . . . . 47<br />

N3050615 . . . . . . . . . . . . . . . . . . . . . . . . . . . 47<br />

N3050620 . . . . . . . . . . . . . . . . . . . . . . . . . . . 47<br />

N3050630 . . . . . . . . . . . . . . . . . . . . . . . . . . . 47<br />

N3050634 . . . . . . . . . . . . . . . . . . . . . . . . . . . 47<br />

N3050655 . . . . . . . . . . . . . . . . . . . . . . . . . . . 47<br />

N3050657 . . . . . . . . . . . . . . . . . . . . . . . . . . . 47<br />

N3050664 . . . . . . . . . . . . . . . . . . . . . . . . . . . 47<br />

N3050670 . . . . . . . . . . . . . . . . . . . . . . . . . . . 47<br />

N3050672 . . . . . . . . . . . . . . . . . . . . . . . . . . . 47<br />

N3050675 . . . . . . . . . . . . . . . . . . . . . . . . . . . 47<br />

N3050680 . . . . . . . . . . . . . . . . . . . . . . . . . . . 47<br />

N3050683 . . . . . . . . . . . . . . . . . . . . . . . . . . . 47<br />

N3050691 . . . . . . . . . . . . . . . . . . . . . . . . . . . 47<br />

N3050702 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />

N3050703 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />

N3050705 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />

N3050707 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />

N3050708 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />

N3050709 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />

N3050710 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />

N3050711 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />

N3050714 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />

N3050715 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />

N3050718 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />

N3050719 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />

N3050721 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />

N3050722 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />

N3050723 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />

N3050726 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />

N3050728 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />

N3050729 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />

N3050730 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />

N3050734 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />

N3050735 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />

N3050737 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />

N3050738 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />

N3050739 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />

N3050741 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />

N3050742 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />

N3050744 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />

N3050745 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />

N3050746 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />

N3050748 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />

N3050749 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />

N3050750 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />

N3050752 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />

N3050755 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />

N3050757 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />

N3050758 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />

N3050761 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />

N3050762 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />

N3050765 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />

N3050766 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />

N3050768 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />

N3050770 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />

N3050771 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />

N3050772 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />

N3050773 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />

N3050775 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />

N3050776 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />

N3050777 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />

N3050778 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />

N3050780 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />

N3050782 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />

N3050783 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />

N3050786 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />

N3050787 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />

N3050789 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />

N3050791 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />

N3050792 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />

N3050801 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />

N3050802 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />

N3050803 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />

N3050804 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />

N3050805 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />

N3050806 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />

N3050807 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />

N3050808 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />

N3050809 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />

N3050810 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />

N3050811 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />

N3050812 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />

N3050813 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />

N3050814 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />

N3050815 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />

N3050816 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />

N3050817 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />

N3050818 . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />

N3050860 . . . . . . . . . . . . . . . . . . . . . . . . . . . 47<br />

N3050861 . . . . . . . . . . . . . . . . . . . . . . . . . . . 47<br />

N3050862 . . . . . . . . . . . . . . . . . . . . . . . . . . . 47<br />

N3050863 . . . . . . . . . . . . . . . . . . . . . . . . . . . 47<br />

N3050864 . . . . . . . . . . . . . . . . . . . . . . . . . . . 47<br />

N3050865 . . . . . . . . . . . . . . . . . . . . . . . . . . . 47<br />

N3050866 . . . . . . . . . . . . . . . . . . . . . . . . . . . 47<br />

N3050867 . . . . . . . . . . . . . . . . . . . . . . . . . . . 47<br />

N3050868 . . . . . . . . . . . . . . . . . . . . . . . . . . . 47<br />

N3050869 . . . . . . . . . . . . . . . . . . . . . . . . . . . 47<br />

N3050870 . . . . . . . . . . . . . . . . . . . . . . . . . . . 47<br />

N3050871 . . . . . . . . . . . . . . . . . . . . . . . . . . . 47<br />

N3050872 . . . . . . . . . . . . . . . . . . . . . . . . . . . 47<br />

N3050873 . . . . . . . . . . . . . . . . . . . . . . . . . . . 47<br />

N3050874 . . . . . . . . . . . . . . . . . . . . . . . . . . . 47<br />

N3051050 . . . . . . . . . . . . . . . . . . . . . . . . . . . 45<br />

N3110109 . . . . . . . . . . . . . . . . . . . . . . . . 17, 20<br />

N3110110 . . . . . . . . . . . . . . . . . . . . . . . . . . . 17<br />

N3110111 . . . . . . . . . . . . . . . . . . . . . . . . . . . 17<br />

N3110145 . . . . . . . . . . . . . . . . . . . . . . . . . . . 31<br />

N3110146 . . . . . . . . . . . . . . . . . . . . . . . . . . . 32<br />

N3110147 . . . . . . . . . . . . . . . . . . . . . . . . . . . 34<br />

N3110149 . . . . . . . . . . . . . . . . . . . . . . . . . . . 32<br />

N3111158 . . . . . . . . . . . . . . . . . . . . . . . . . . . 17<br />

N3141005 . . . . . . . . . . . . . . . . . . . . . . . . . . . 60<br />

N3141009 . . . . . . . . . . . . . . . . . . . . . . . . . . . 64<br />

N3141010 . . . . . . . . . . . . . . . . . . . . . . . . . . . 64<br />

N3141011 . . . . . . . . . . . . . . . . . . . . . . . . . . . 60<br />

N3141012 . . . . . . . . . . . . . . . . . . . . . . . . . . . 60<br />

N3141014 . . . . . . . . . . . . . . . . . . . . . 57, 60, 63<br />

N3141015 . . . . . . . . . . . . . . . . . . . . . . . . 57, 60<br />

N3141016 . . . . . . . . . . . . . . . . . . . . . . . . 58, 60<br />

N3141017 . . . . . . . . . . . . . . . . . . . . . . . . . . . 60<br />

N3141018 . . . . . . . . . . . . . . . . . . . . . . . . 60, 63<br />

N3141019 . . . . . . . . . . . . . . . . . . . . . . . . 57, 60<br />

N3141020 . . . . . . . . . . . . . . . . . . . . . . . . . . . 60<br />

N3141021 . . . . . . . . . . . . . . . . . . . . . 57-58, 60<br />

N3141022 . . . . . . . . . . . . . . . . . . . . . 57-58, 60<br />

N3141023 . . . . . . . . . . . . . . . . . . . . . . . . . . . 60<br />

N3141025 . . . . . . . . . . . . . . . . . . . . . . . . . . . 61<br />

N3141026 . . . . . . . . . . . . . . . . . . . . . 61-62, 64<br />

N3141027 . . . . . . . . . . . . . . . . . . . . . . . . 61, 64<br />

N3141028 . . . . . . . . . . . . . . . . . . . . . . . . . . . 61<br />

N3141029 . . . . . . . . . . . . . . . . . . . . . . . . 61-62<br />

N3141030 . . . . . . . . . . . . . . . . . . . . . 61-62, 64<br />

N3141031 . . . . . . . . . . . . . . . . . . . . . 61-62, 64<br />

N3141032 . . . . . . . . . . . . . . . . . . . . . 61-62, 64<br />

N3142000 . . . . . . . . . . . . . . . . . . . . . . . . . . . 62<br />

N3142001 . . . . . . . . . . . . . . . . . . . . . . . . . . . 62<br />

N3142002 . . . . . . . . . . . . . . . . . . . . . . . . . . . 62<br />

N3142003 . . . . . . . . . . . . . . . . . . . . . . . . . . . 62<br />

N3142013 . . . . . . . . . . . . . . . . . . . . . . . . 60, 63<br />

N3142345 . . . . . . . . . . . . . . . . . . . . . . . . . . . 57<br />

N3142346 . . . . . . . . . . . . . . . . . . . . . . . . . . . 57<br />

N3142347 . . . . . . . . . . . . . . . . . . . . . . . . . . . 57<br />

N3142348 . . . . . . . . . . . . . . . . . . . . . . . . . . . 57<br />

N3142349 . . . . . . . . . . . . . . . . . . . . . . . . 57-58<br />

N3142350 . . . . . . . . . . . . . . . . . . . . . . . . 57-58<br />

N3142351 . . . . . . . . . . . . . . . . . . . . . . . . . . . 57<br />

N3142352 . . . . . . . . . . . . . . . . . . . . . . . . . . . 57<br />

N3142353 . . . . . . . . . . . . . . . . . . . . . . . . . . . 57<br />

N3142354 . . . . . . . . . . . . . . . . . . . . . . . . . . . 57<br />

N3142355 . . . . . . . . . . . . . . . . . . . . . . . . . . . 59<br />

N3142356 . . . . . . . . . . . . . . . . . . . . . . . . . . . 59<br />

N3142357 . . . . . . . . . . . . . . . . . . . . . . . . . . . 59<br />

N3142360 . . . . . . . . . . . . . . . . . . . . . . . . . . . 59<br />

N3142363 . . . . . . . . . . . . . . . . . . . . . . . . . . . 59<br />

N3142364 . . . . . . . . . . . . . . . . . . . . . . . . . . . 59<br />

N3142366 . . . . . . . . . . . . . . . . . . . . . . . . . . . 59<br />

N3142367 . . . . . . . . . . . . . . . . . . . . . . . . . . . 62<br />

N3142368 . . . . . . . . . . . . . . . . . . . . . . . . . . . 62<br />

N3142369 . . . . . . . . . . . . . . . . . . . . . . . . . . . 62<br />

N3142370 . . . . . . . . . . . . . . . . . . . . . . . . . . . 62<br />

N3142371 . . . . . . . . . . . . . . . . . . . . . . . . . . . 62<br />

N3142372 . . . . . . . . . . . . . . . . . . . . . . . . . . . 62<br />

N3142373 . . . . . . . . . . . . . . . . . . . . . . . . . . . 62<br />

N3142374 . . . . . . . . . . . . . . . . . . . . . . . . . . . 62<br />

N3142398 . . . . . . . . . . . . . . . . . . . . . . . . 61-62<br />

N3142399 . . . . . . . . . . . . . . . . . . . . . . . . . . . 60<br />

N3142400 . . . . . . . . . . . . . . . . . . . . . . . . . . . 60<br />

N3142409 . . . . . . . . . . . . . . . . . . . . . . . . . . . 58<br />

N3142410 . . . . . . . . . . . . . . . . . . . . . . . . . . . 58<br />

N3142411 . . . . . . . . . . . . . . . . . . . . . . . . . . . 58<br />

N3142412 . . . . . . . . . . . . . . . . . . . . . . . . . . . 58<br />

N3142413 . . . . . . . . . . . . . . . . . . . . . . . . . . . 58<br />

N3142415 . . . . . . . . . . . . . . . . . . . . . . . . . . . 58<br />

N3142416 . . . . . . . . . . . . . . . . . . . . . 58, 60, 63<br />

N3142418 . . . . . . . . . . . . . . . . . . . . . . . . . . . 60<br />

N3142419 . . . . . . . . . . . . . . . . . . . . . . . . . . . 63<br />

N3142420 . . . . . . . . . . . . . . . . . . . . . . . . . . . 63<br />

N3142423 . . . . . . . . . . . . . . . . . . . . . . . . . . . 63<br />

N3142424 . . . . . . . . . . . . . . . . . . . . . . . . . . . 63<br />

N3142425 . . . . . . . . . . . . . . . . . . . . . . . . . . . 63<br />

N3142427 . . . . . . . . . . . . . . . . . . . . . . . . . . . 63<br />

N3142428 . . . . . . . . . . . . . . . . . . . . . . . . . . . 63<br />

N3142429 . . . . . . . . . . . . . . . . . . . . . . . . . . . 63<br />

N3142430 . . . . . . . . . . . . . . . . . . . . . . . . . . . 59<br />

N3142431 . . . . . . . . . . . . . . . . . . . . . . . . . . . 59<br />

N3142435 . . . . . . . . . . . . . . . . . . . . . . . . . . . 64<br />

N3142436 . . . . . . . . . . . . . . . . . . . . . . . . . . . 63<br />

N3142437 . . . . . . . . . . . . . . . . . . . . . . . . . . . 63<br />

N3142438 . . . . . . . . . . . . . . . . . . . . . . . . . . . 64<br />

N3142449 . . . . . . . . . . . . . . . . . . . . . . . . . . . 64<br />

N3142450 . . . . . . . . . . . . . . . . . . . . . . . . . . . 64<br />

N3142451 . . . . . . . . . . . . . . . . . . . . . . . . . . . 64<br />

N3142452 . . . . . . . . . . . . . . . . . . . . . . . . . . . 60<br />

N3142453 . . . . . . . . . . . . . . . . . . . . . . . . . . . 64<br />

N3142454 . . . . . . . . . . . . . . . . . . . . . . . . . . . 64<br />

N3142456 . . . . . . . . . . . . . . . . . . . . . . . . . . . 60<br />

N3142485 . . . . . . . . . . . . . . . . . . . . . . . . . . . 59<br />

N3142486 . . . . . . . . . . . . . . . . . . . . . . . . . . . 59<br />

N3150131 . . . . . . . . . . . . . . . . . . . . . . . . . . . 48<br />

N3150188 . . . . . . . . . . . . . . . . . . . . . . . . 17, 19<br />

N3150303 . . . . . . . . . . . . . . . . . . . . . . . . . . . 48<br />

N5001409 . . . . . . . . . . . . . . . . . . . . . . . . . . . 77<br />

N5150060 . . . . . . . . . . . . . . . . . . . . . . . . . . 174<br />

N5150100 . . . . . . . . . . . . . . . . . . . . . . . . . . 178<br />

N5150103 . . . . . . . . . . . . . . . . . . . . . . . . . . 178<br />

N5150130 . . . . . . . . . . . . . . . . . . . . . . . . . . 332<br />

Part No. Page Part No. Page Part No. Page


N5150160 – N5370490 Part Number Index<br />

Index<br />

Part Number<br />

419<br />

N5150160 . . . . . . . . . . . . . . . . . . . . . . . . . . 176<br />

N5150162 . . . . . . . . . . . . . . . . . . . . . . . . . . 330<br />

N5150165 . . . . . . . . . . . . . . . . . . . . . . . . . . 176<br />

N5150166 . . . . . . . . . . . . . . . . . . . . . . . . . . 176<br />

N5150167 . . . . . . . . . . . . . . . . . . . . . . . . . . 330<br />

N5150181 . . . . . . . . . . . . . . . . . . . . . . 176, 330<br />

N5150183 . . . . . . . . . . . . . . . . . . . . . . . . . . 332<br />

N5150187 . . . . . . . . . . . . . . . . . . . . . . . . . . 332<br />

N5150262 . . . . . . . . . . . . . . . . . . . . . . . . . . 330<br />

N5150267 . . . . . . . . . . . . . . . . . . . . . . . . . . 330<br />

N5150349 . . . . . . . . . . . . . . . . . . . . . . 178, 332<br />

N5150512 . . . . . . . . . . . . . . . . . . . . . . 178, 332<br />

N5150518 . . . . . . . . . . . . . . . . . . . . . . 178, 332<br />

N5150715 . . . . . . . . . . . . . . . . . . . . . . 178, 332<br />

N5156021 . . . . . . . . . . . . . . . . . . . . . . 178, 332<br />

N5156025 . . . . . . . . . . . . . . . . . . . . . . 178, 332<br />

N5190172 . . . . . . . . . . . . . . . . . . . . . . . . . . 369<br />

N5190180 . . . . . . . . . . . . . . . . . . . . . . . . . . 343<br />

N5190196 . . . . . . . . . . . . . . . . . . . . . . . . . . 369<br />

N5190197 . . . . . . . . . . . . . . . . . . . . . . . . . . 369<br />

N5190202 . . . . . . . . . . . . . . . . . . . . . . . . . . 369<br />

N5190203 . . . . . . . . . . . . . . . . . . . . . . . . . . 369<br />

N5190226 . . . . . . . . . . . . . . . . . . . . . . . . . . 348<br />

N5190264 . . . . . . . . . . . . . . . . . . . . . . . . . . 369<br />

N5190269 . . . . . . . . . . . . . . . . . . . . . . . . . . 355<br />

N5190270 . . . . . . . . . . . . . . . . . . . . . . . . . . 355<br />

N5190271 . . . . . . . . . . . . . . . . . . . . . . . . . . 355<br />

N5190276 . . . . . . . . . . . . . . . . . . . . . . . . . . 371<br />

N5190279 . . . . . . . . . . . . . . . . . . . . . . . . . . 371<br />

N5190280 . . . . . . . . . . . . . . . . . . . . . . . . . . 372<br />

N5190282 . . . . . . . . . . . . . . . . . . . . . . . . . . 369<br />

N5190283 . . . . . . . . . . . . . . . . . . . . . . . . . . 372<br />

N5190284 . . . . . . . . . . . . . . . . . . . . . . . . . . 369<br />

N5190285 . . . . . . . . . . . . . . . . . . . . . . . . . . 371<br />

N5190330 . . . . . . . . . . . . . . . . . . . . . . . . . . 371<br />

N5190370 . . . . . . . . . . . . . . . . . . . . . . . . . . 366<br />

N5190376 . . . . . . . . . . . . . . . . . . . . . . 361, 365<br />

N5190377 . . . . . . . . . . . . . . . . . . . . . . 357, 365<br />

N5190378 . . . . . . . . . . . . . . . . . . . . . . 361, 365<br />

N5190393 . . . . . . . . . . . . . . . . . . . . . . 357, 364<br />

N5190399 . . . . . . . . . . . . . . . . . . . . . . . . . . 364<br />

N5190416 . . . . . . . . . . . . . . . . . . . . . . . . . . 365<br />

N5190417 . . . . . . . . . . . . . . . . . . . . . . . . . . 366<br />

N5190462 . . . . . . . . . . . . . . . . . . . . . . . . . . 354<br />

N5190504 . . . . . . . . . . . . . . . . . . . . . . . . . . 348<br />

N5190510 . . . . . . . . . . . . . . . . . . . . . . . . . . 369<br />

N5190511 . . . . . . . . . . . . . . . . . . . . . . . . . . 369<br />

N5190512 . . . . . . . . . . . . . . . . . . . . . . . . . . 370<br />

N5190515 . . . . . . . . . . . . . . . . . . . . . . . . . . 371<br />

N5190516 . . . . . . . . . . . . . . . . . . . . . . . . . . 371<br />

N5190606 . . . . . . . . . . . . . . . . . . . . . . . . . . 361<br />

N5190609 . . . . . . . . . . . . . . . . . . . . . . 363, 365<br />

N5190611 . . . . . . . . . . . . . . . . . . . . . . 363, 365<br />

N5190613 . . . . . . . . . . . . . . . . . . . . . . . . . . 366<br />

N5190614 . . . . . . . . . . . . . . . . . . . . . . . . . . 357<br />

N5190615 . . . . . . . . . . . . . . . . . . . . . . 363, 365<br />

N5190616 . . . . . . . . . . . . . . . . . . . . . . . . . . 368<br />

N5190617 . . . . . . . . . . . . . . . . . . . . . . . . . . 366<br />

N5190619 . . . . . . . . . . . . . . . . . . . . . . . . . . 365<br />

N5190738 . . . . . . . . . . . . . . . . . . . . . . . . . . 348<br />

N5190762 . . . . . . . . . . . . . . . . . . . . . . . . . . 350<br />

N5190763 . . . . . . . . . . . . . . . . . . . . . . . . . . 364<br />

N5190784 . . . . . . . . . . . . . . . . . . . . . . . . . . 348<br />

N5190786 . . . . . . . . . . . . . . . . . . . . . . . . . . 369<br />

N5190788 . . . . . . . . . . . . . . . . . . . . . . 346, 372<br />

N5190869 . . . . . . . . . . . . . . . . . . . . . . . . . . 368<br />

N5191009 . . . . . . . . . . . . . . . . . . . . . . . . . . 348<br />

N5191085 . . . . . . . . . . . . . . . . . . . . . . . . . . 351<br />

N5191333 . . . . . . . . . . . . . . . . . . . . . . . . . . 351<br />

N5191469 . . . . . . . . . . . . . . . . . . . . . . . . . . 366<br />

N5191472 . . . . . . . . . . . . . . . . . . . . . . . . . . 357<br />

N5191549 . . . . . . . . . . . . . . . . . . 357, 361, 365<br />

N5191552 . . . . . . . . . . . . . . . . . . . . . . . . . . 370<br />

N5191662 . . . . . . . . . . . . . . . . . . . . . . . . . . 356<br />

N5191700 . . . . . . . . . . . . . . . . . . . . . . 363, 365<br />

N5191792 . . . . . . . . . . . . . . . . . . . . . . . . . . 366<br />

N5191837 . . . . . . . . . . . . . . . . . . . . . . . . . . 361<br />

N5191845 . . . . . . . . . . . . . . . . . . . . . . 348, 351<br />

N5191875 . . . . . . . . . . . . . . . . . . . . . . 353, 369<br />

N5192094 . . . . . . . . . . . . . . . . . . . . . . . . . . 364<br />

N5200001 . . . . . . . . . . . . . . . . . . . . . . . . . . 346<br />

N5200032 . . . . . . . . . . . . . . . . . . . . . . . . . . 348<br />

N5200033 . . . . . . . . . . . . . . . . . . . . . . . . . . 348<br />

N5200040 . . . . . . . . . . . . . . . . . . . . . . . . . . 372<br />

N5201016 . . . . . . . . . . . . . . . . . . . . . . . . . . 346<br />

N5202019 . . . . . . . . . . . . . . . . . . . . . . . . . . 355<br />

N5203020 . . . . . . . . . . . . . . . . . . . . . . 369, 372<br />

N5350110 . . . . . . . . . . . . . . . . . . . . . . . . . . 348<br />

N5350130 . . . . . . . . . . . . . . . . . . . . . . . . . . 347<br />

N5350131 . . . . . . . . . . . . . . . . . . . . . . . . . . 347<br />

N5350201 . . . . . . . . . . . . . . . . . . . . . . . . . . 367<br />

N5350202 . . . . . . . . . . . . . . . . . . . . . . 355, 367<br />

N5350203 . . . . . . . . . . . . . . . . . . . . . . . . . . 367<br />

N5350204 . . . . . . . . . . . . . . . . . . . . . . . . . . 367<br />

N5350302 . . . . . . . . . . . . . . . . . . . . . . . . . . 348<br />

N5351002 . . . . . . . . . . . . . . . . . . . . . . . . . . 348<br />

N5351009 . . . . . . . . . . . . . . . . . . . . . . . . . . 348<br />

N5352004 . . . . . . . . . . . . . . . . . . . . . . . . . . 367<br />

N5352005 . . . . . . . . . . . . . . . . . . . . . . . . . . 367<br />

N5352006 . . . . . . . . . . . . . . . . . . . . . . . . . . 367<br />

N5352027 . . . . . . . . . . . . . . . . . . . . . . . . . . 367<br />

N5353009 . . . . . . . . . . . . . . . . . . . . . . . . . . 364<br />

N5353013 . . . . . . . . . . . . . . . . . . . . . . . . . . 365<br />

N5353021 . . . . . . . . . . . . . . . . . . . . . . . . . . 365<br />

N5353023 . . . . . . . . . . . . . . . . . . . . . . . . . . 364<br />

N5353030 . . . . . . . . . . . . . . . . . . . . . . . . . . 363<br />

N5353031 . . . . . . . . . . . . . . . . . . . . . . . . . . 363<br />

N5353032 . . . . . . . . . . . . . . . . . . . . . . . . . . 359<br />

N5353035 . . . . . . . . . . . . . . . . . . . . . . . . . . 356<br />

N5353036 . . . . . . . . . . . . . . . . . . . . . . . . . . 365<br />

N5353037 . . . . . . . . . . . . . . . . . . . . . . . . . . 365<br />

N5353038 . . . . . . . . . . . . . . . . . . . . . . . . . . 365<br />

N5353039 . . . . . . . . . . . . . . . . . . . . . . . . . . 365<br />

N5353040 . . . . . . . . . . . . . . . . . . . . . . . . . . 365<br />

N5353041 . . . . . . . . . . . . . . . . . . . . . . . . . . 365<br />

N5353042 . . . . . . . . . . . . . . . . . . . . . . . . . . 365<br />

N5353043 . . . . . . . . . . . . . . . . . . . . . . . . . . 365<br />

N5353044 . . . . . . . . . . . . . . . . . . . . . . . . . . 365<br />

N5353045 . . . . . . . . . . . . . . . . . . . . . . . . . . 365<br />

N5353046 . . . . . . . . . . . . . . . . . . . . . . . . . . 365<br />

N5353047 . . . . . . . . . . . . . . . . . . . . . . . . . . 365<br />

N5353048 . . . . . . . . . . . . . . . . . . . . . . . . . . 364<br />

N5353050 . . . . . . . . . . . . . . . . . . . . . . . . . . 365<br />

N5353051 . . . . . . . . . . . . . . . . . . . . . . . . . . 365<br />

N5353052 . . . . . . . . . . . . . . . . . . . . . . . . . . 365<br />

N5353054 . . . . . . . . . . . . . . . . . . . . . . . . . . 365<br />

N5353056 . . . . . . . . . . . . . . . . . . . . . . . . . . 365<br />

N5353057 . . . . . . . . . . . . . . . . . . . . . . . . . . 365<br />

N5353059 . . . . . . . . . . . . . . . . . . . . . . . . . . 365<br />

N5353060 . . . . . . . . . . . . . . . . . . . . . . . . . . 366<br />

N5353061 . . . . . . . . . . . . . . . . . . . . . . . . . . 366<br />

N5353062 . . . . . . . . . . . . . . . . . . . . . . . . . . 366<br />

N5353063 . . . . . . . . . . . . . . . . . . . . . . . . . . 366<br />

N5353065 . . . . . . . . . . . . . . . . . . . . . . . . . . 366<br />

N5353073 . . . . . . . . . . . . . . . . . . . . . . . . . . 366<br />

N5353074 . . . . . . . . . . . . . . . . . . . . . . . . . . 366<br />

N5353075 . . . . . . . . . . . . . . . . . . . . . . . . . . 366<br />

N5353076 . . . . . . . . . . . . . . . . . . . . . . . . . . 366<br />

N5353077 . . . . . . . . . . . . . . . . . . . . . . . . . . 366<br />

N5353078 . . . . . . . . . . . . . . . . . . . . . . . . . . 362<br />

N5353079 . . . . . . . . . . . . . . . . . . . . . . . . . . 358<br />

N5353081 . . . . . . . . . . . . . . . . . . . . . . . . . . 358<br />

N5353082 . . . . . . . . . . . . . . . . . . . . . . . . . . 358<br />

N5353083 . . . . . . . . . . . . . . . . . . . . . . . . . . 358<br />

N5353084 . . . . . . . . . . . . . . . . . . . . . . . . . . 358<br />

N5353085 . . . . . . . . . . . . . . . . . . . . . . . . . . 362<br />

N5353086 . . . . . . . . . . . . . . . . . . . . . . . . . . 362<br />

N5353087 . . . . . . . . . . . . . . . . . . 358-359, 362<br />

N5353095 . . . . . . . . . . . . . . . . . . . . . . . . . . 364<br />

N5353114 . . . . . . . . . . . . . . . . . . . . . . . . . . 366<br />

N5353115 . . . . . . . . . . . . . . . . . . . . . . . . . . 366<br />

N5353116 . . . . . . . . . . . . . . . . . . . . . . . . . . 366<br />

N5353117 . . . . . . . . . . . . . . . . . . . . . . . . . . 366<br />

N5353118 . . . . . . . . . . . . . . . . . . . . . . . . . . 366<br />

N5353140 . . . . . . . . . . . . . . . . . . . . . . . . . . 366<br />

N5353141 . . . . . . . . . . . . . . . . . . . . . . . . . . 366<br />

N5353144 . . . . . . . . . . . . . . . . . . . . . . . . . . 366<br />

N5356000 . . . . . . . . . . . . . . . . . . . . . . . . . . 354<br />

N5356001 . . . . . . . . . . . . . . . . . . . . . . . . . . 354<br />

N5356002 . . . . . . . . . . . . . . . . . . . . . . 340-341<br />

N5356003 . . . . . . . . . . . . . . . . . . . . . . . . . . 340<br />

N5356004 . . . . . . . . . . . . . . . . . . . . . . . . . . 340<br />

N5356005 . . . . . . . . . . . . . . . . . . . . . . . . . . 340<br />

N5356006 . . . . . . . . . . . . . . . . . . . . . . . . . . 340<br />

N5356007 . . . . . . . . . . . . . . . . . . . . . . . . . . 340<br />

N5356008 . . . . . . . . . . . . . . . . . . . . . . . . . . 339<br />

N5356009 . . . . . . . . . . . . . . . . . . . . . . . . . . 339<br />

N5356010 . . . . . . . . . . . . . . . . . . . . . . 338, 342<br />

N5356012 . . . . . . . . . . . . . . . . . . 338, 342, 367<br />

N5356016 . . . . . . . . . . . . . . . . . . . . . . 343, 367<br />

N5356017 . . . . . . . . . . . . . . . . . . . . . . 343, 367<br />

N5356018 . . . . . . . . . . . . . . . . . . . . . . . . . . 367<br />

N5356019 . . . . . . . . . . . . . . . . . . . . . . 343, 367<br />

N5356020 . . . . . . . . . . . . . . . . . . 341, 343, 367<br />

N5356021 . . . . . . . . . . . . . . . . . . . . . . 342, 367<br />

N5356022 . . . . . . . . . . . . . . . . . . . . . . . . . . 367<br />

N5356023 . . . . . . . . . . . . . . . . . . . . . . . . . . 367<br />

N5356025 . . . . . . . . . . . . . . . . . . . . . . 341, 367<br />

N5356026 . . . . . . . . . . . . . . . . . . . . . . 341, 367<br />

N5356027 . . . . . . . . . . . . . . . . . . . . . . . . . . 344<br />

N5356028 . . . . . . . . . . . . . . . . . . . . . . . . . . 344<br />

N5356029 . . . . . . . . . . . . . . . . . . . . . . . . . . 365<br />

N5356030 . . . . . . . . . . . . . . . . . . . . . . . . . . 344<br />

N5356031 . . . . . . . . . . . . . . . . . . . . . . . . . . 344<br />

N5356032 . . . . . . . . . . . . . . . . . . . . . . . . . . 344<br />

N5356033 . . . . . . . . . . . . . . . . . . . . . . . . . . 344<br />

N5356034 . . . . . . . . . . . . . . . . . . 341-342, 367<br />

N5356035 . . . . . . . . . . . . . . . . . . . . . . . . . . 344<br />

N5356036 . . . . . . . . . . . . . . . . . . . . . . . . . . 344<br />

N5360016 . . . . . . . . . . . . . . . . . . . . . . . . . . 349<br />

N5360142 . . . . . . . . . . . . . . . . . . . . . . . . . . 350<br />

N5360188 . . . . . . . . . . . . . . . . . . . . . . . . . . 346<br />

N5360236 . . . . . . . . . . . . . . . . . . . . . . . . . . 351<br />

N5360321 . . . . . . . . . . . . . . . . . . . . . . . . . . 346<br />

N5361078 . . . . . . . . . . . . . . . . . . . . . . . . . . 351<br />

N5361180 . . . . . . . . . . . . . . . . . . . . . . . . . . 351<br />

N5365044 . . . . . . . . . . . . . . . . . . . . . . . . . . 349<br />

N5370103 . . . . . . . . . . . . . . . . . . . . . . . . . . 354<br />

N5370142 . . . . . . . . . . . . . . . . . . . . . . . . . . 348<br />

N5370147 . . . . . . . . . . . . . . . . . . . . . . . . . . 347<br />

N5370153 . . . . . . . . . . . . . . . . . . . . . . . . . . 350<br />

N5370205 . . . . . . . . . . . . . . . . . . . . . . . . . . 347<br />

N5370206 . . . . . . . . . . . . . . . . . . . . . . . . . . 347<br />

N5370207 . . . . . . . . . . . . . . . . . . . . . . . . . . 347<br />

N5370208 . . . . . . . . . . . . . . . . . . . . . . . . . . 347<br />

N5370236 . . . . . . . . . . . . . . . . . . . . . . . . . . 351<br />

N5370298 . . . . . . . . . . . . . . . . . . . . . . . . . . 346<br />

N5370299 . . . . . . . . . . . . . . . . . . . . . . . . . . 346<br />

N5370331 . . . . . . . . . . . . . . . . . . . . . . . . . . 369<br />

N5370332 . . . . . . . . . . . . . . . . . . . . . . . . . . 369<br />

N5370459 . . . . . . . . . . . . . . . . . . . . . . . . . . 369<br />

N5370464 . . . . . . . . . . . . . . . . . . . . . . . . . . 372<br />

N5370478 . . . . . . . . . . . . . . . . . . . . . . . . . . 369<br />

N5370487 . . . . . . . . . . . . . . . . . . . . . . . . . . 371<br />

N5370488 . . . . . . . . . . . . . . . . . . . . . . . . . . 371<br />

N5370490 . . . . . . . . . . . . . . . . . . . . . . . . . . 371<br />

Part No. Page Part No. Page Part No. Page<br />

See page 4 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

See page 2 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong>


Index Part Number N5370540 – N6120009<br />

Index<br />

Part Number<br />

420<br />

N5370540 . . . . . . . . . . . . . . . . . . . . . . . . . . 347<br />

N5370550 . . . . . . . . . . . . . . . . . . . . . . . . . . 372<br />

N5370552 . . . . . . . . . . . . . . . . . . . . . . . . . . 370<br />

N5370553 . . . . . . . . . . . . . . . . . . . . . . . . . . 370<br />

N5370554 . . . . . . . . . . . . . . . . . . . . . . . . . . 370<br />

N5370555 . . . . . . . . . . . . . . . . . . . . . . . . . . 370<br />

N5370600 . . . . . . . . . . . . . . . . . . . . . . . . . . 374<br />

N5370603 . . . . . . . . . . . . . . . . . . . . . . . . . . 374<br />

N5370606 . . . . . . . . . . . . . . . . . . . . . . . . . . 374<br />

N5370610 . . . . . . . . . . . . . . . . . . . . . . . . . . 374<br />

N5370611 . . . . . . . . . . . . . . . . . . . . . . . . . . 374<br />

N5370619 . . . . . . . . . . . . . . . . . . . . . . . . . . 374<br />

N5370620 . . . . . . . . . . . . . . . . . . . . . . . . . . 374<br />

N5370622 . . . . . . . . . . . . . . . . . . . . . . . . . . 374<br />

N5370623 . . . . . . . . . . . . . . . . . . . . . . . . . . 374<br />

N5370637 . . . . . . . . . . . . . . . . . . . . . . . . . . 373<br />

N5370638 . . . . . . . . . . . . . . . . . . . . . . . . . . 373<br />

N5370647 . . . . . . . . . . . . . . . . . . . . . . . . . . 373<br />

N5370648 . . . . . . . . . . . . . . . . . . . . . . . . . . 373<br />

N5370665 . . . . . . . . . . . . . . . . . . . . . . . . . . 373<br />

N5370666 . . . . . . . . . . . . . . . . . . . . . . . . . . 373<br />

N5370667 . . . . . . . . . . . . . . . . . . . . . . . . . . 373<br />

N5370668 . . . . . . . . . . . . . . . . . . . . . . . . . . 373<br />

N5370669 . . . . . . . . . . . . . . . . . . . . . . . . . . 373<br />

N5370671 . . . . . . . . . . . . . . . . . . . . . . . . . . 374<br />

N5370672 . . . . . . . . . . . . . . . . . . . . . . . . . . 374<br />

N5370673 . . . . . . . . . . . . . . . . . . . . . . . . . . 374<br />

N5370674 . . . . . . . . . . . . . . . . . . . . . . . . . . 374<br />

N5370675 . . . . . . . . . . . . . . . . . . . . . . . . . . 374<br />

N5370676 . . . . . . . . . . . . . . . . . . . . . . . . . . 374<br />

N5370679 . . . . . . . . . . . . . . . . . . . . . . . . . . 373<br />

N5372060 . . . . . . . . . . . . . . . . . . . . . . . . . . 347<br />

N5372187 . . . . . . . . . . . . . . . . . . . . . . . . . . 347<br />

N5373009 . . . . . . . . . . . . . . . . . . . . . . . . . . 347<br />

N5373126 . . . . . . . . . . . . . . . . . . . . . . . . . . 351<br />

N5374098 . . . . . . . . . . . . . . . . . . . . . . . . . . 347<br />

N5374099 . . . . . . . . . . . . . . . . . . . . . . . . . . 347<br />

N5376097 . . . . . . . . . . . . . . . . . . . . . . . . . . 345<br />

N5376806 . . . . . . . . . . . . . . . . . . . . . . . . . . 369<br />

N5376817 . . . . . . . . . . . . . . . . . . . . . . . . . . 369<br />

N5380015 . . . . . . . . . . . . . . . . . . . . . . . . . . 353<br />

N5380037 . . . . . . . . . . . . . . . . . . . . . . . . . . 353<br />

N5380051 . . . . . . . . . . . . . . . . . . . . . . . . . . 353<br />

N5380052 . . . . . . . . . . . . . . . . . . . . . . . . . . 353<br />

N5380053 . . . . . . . . . . . . . . . . . . . . . . . . . . 353<br />

N5380057 . . . . . . . . . . . . . . . . . . . . . . 353, 367<br />

N5380058 . . . . . . . . . . . . . . . . . . . . . . 353, 367<br />

N5380062 . . . . . . . . . . . . . . . . . . . . . . . . . . 353<br />

N5380063 . . . . . . . . . . . . . . . . . . . . . . . . . . 353<br />

N5380071 . . . . . . . . . . . . . . . . . . . . . . 353, 367<br />

N5381081 . . . . . . . . . . . . . . . . . . . . . . . . . . 353<br />

N5390101 . . . . . . . . . . . . . . . . . . . . . . . . . . 356<br />

N5390102 . . . . . . . . . . . . . . . . . . . . . . . . . . 356<br />

N5390105 . . . . . . . . . . . . . . . . . . 356, 358, 360<br />

N5390107 . . . . . . . . . . . . . . . . . . 356, 360, 362<br />

N5390122 . . . . . . . . . . . . . . . . . . . . . . . . . . 356<br />

N5390128 . . . . . . . . . . . . . . . . . . . . . . . . . . 366<br />

N5390131 . . . . . . . . . . . . . . . . . . . . . . . . . . 358<br />

N5390132 . . . . . . . . . . . . . . . . . . . . . . . . . . 362<br />

N5390133 . . . . . . . . . . . . . . . . . . . . . . . . . . 360<br />

N5390134 . . . . . . . . . . . . . . . . . . . . . . . . . . 363<br />

N5390135 . . . . . . . . . . . . . . . . . . . . . . . . . . 361<br />

N5390136 . . . . . . . . . . . . . . . . . . . . . . . . . . 357<br />

N5390137 . . . . . . . . . . . . . . . . . . . . . . . . . . 357<br />

N5390138 . . . . . . . . . . . . . . . . . . . . . . . . . . 361<br />

N5390141 . . . . . . . . . . . . . . . . . . . . . . . . . . 366<br />

N5390143 . . . . . . . . . . . . . . . . . . . . . . . . . . 360<br />

N5390144 . . . . . . . . . . . . . . . . . . . . . . . . . . 360<br />

N5390145 . . . . . . . . . . . . . . . . . . . . . . . . . . 360<br />

N5390146 . . . . . . . . . . . . . . . . . . . . . . . . . . 360<br />

N5390154 . . . . . . . . . . . . . . . . . . . . . . . . . . 362<br />

N5390156 . . . . . . . . . . . . . . . . . . . . . . . . . . 362<br />

N5390157 . . . . . . . . . . . . . . . . . . . . . . . . . . 363<br />

N5390174 . . . . . . . . . . . . . . . . . . . . . . . . . . 358<br />

N5390175 . . . . . . . . . . . . . . . . . . . . . . 356, 358<br />

N5390176 . . . . . . . . . . . . . . . . . . . . . . . . . . 358<br />

N5390177 . . . . . . . . . . . . . . . . . . . . . . . . . . 362<br />

N5390178 . . . . . . . . . . . . . . . . . . . . . . . . . . 362<br />

N5390193 . . . . . . . . . . . . . . . . . . . . . . . . . . 362<br />

N5390197 . . . . . . . . . . . . . . . . . . . . . . . . . . 356<br />

N5390420 . . . . . . . . . . . . . . . . . . . . . . . . . . 356<br />

N5390426 . . . . . . . . . . . . . . . . . . . . . . . . . . 356<br />

N5390427 . . . . . . . . . . . . . . . . . . . . . . . . . . 356<br />

N5390428 . . . . . . . . . . . . . . . . . . . . . . . . . . 356<br />

N5390451 . . . . . . . . . . . . . . . . . . . . . . . . . . 356<br />

N5390452 . . . . . . . . . . . . . . . . . . . . . . . . . . 356<br />

N5390453 . . . . . . . . . . . . . . . . . . . . . . . . . . 356<br />

N5390460 . . . . . . . . . . . . . . . . . . . . . . . . . . 361<br />

N5390461 . . . . . . . . . . . . . . . . . . . . . . . . . . 361<br />

N5390462 . . . . . . . . . . . . . . . . . . . . . . . . . . 361<br />

N5390463 . . . . . . . . . . . . . . . . . . . . . . . . . . 361<br />

N5390464 . . . . . . . . . . . . . . . . . . . . . . . . . . 359<br />

N5390465 . . . . . . . . . . . . . . . . . . . . . . . . . . 359<br />

N5390466 . . . . . . . . . . . . . . . . . . . . . . . . . . 359<br />

N5390467 . . . . . . . . . . . . . . . . . . . . . . . . . . 359<br />

N5390468 . . . . . . . . . . . . . . . . . . . . . . . . . . 359<br />

N5390469 . . . . . . . . . . . . . . . . . . . . . . . . . . 359<br />

N5390470 . . . . . . . . . . . . . . . . . . . . . . . . . . 359<br />

N5390471 . . . . . . . . . . . . . . . . . . . . . . . . . . 359<br />

N5390472 . . . . . . . . . . . . . . . . . . . . . . . . . . 359<br />

N5390478 . . . . . . . . . . . . . . . . . . . . . . . . . . 356<br />

N5391014 . . . . . . . . . . . . . . . . . . . . . . . . . . 360<br />

N5391015 . . . . . . . . . . . . . . . . . . . . . . . . . . 360<br />

N5391016 . . . . . . . . . . . . . . . . . . . . . . . . . . 356<br />

N5391017 . . . . . . . . . . . . . . . . . . . . . . . . . . 356<br />

N5391048 . . . . . . . . . . . . . . . . . . . . . . . . . . 366<br />

N5391051 . . . . . . . . . . . . . . . . . . . . . . . . . . 366<br />

N5391054 . . . . . . . . . . . . . . . . . . . . . . . . . . 356<br />

N5391063 . . . . . . . . . . . . . . . . . . . . . . . . . . 356<br />

N5391085 . . . . . . . . . . . . . . . . . . . . . . . . . . 366<br />

N5391090 . . . . . . . . . . . . . . . . . . . . . . . . . . 366<br />

N5391093 . . . . . . . . . . . . . . . . . . . . . . . . . . 357<br />

N5391094 . . . . . . . . . . . . . . . . . . . . . . . . . . 357<br />

N5391095 . . . . . . . . . . . . . . . . . . . . . . . . . . 357<br />

N5391104 . . . . . . . . . . . . . . . . . . . . . . . . . . 366<br />

N5391181 . . . . . . . . . . . . . . . . . . 357, 364-365<br />

N5391183 . . . . . . . . . . . . . . . . . . . . . . . . . . 357<br />

N5391184 . . . . . . . . . . . . . . . . . . . . . . . . . . 366<br />

N6000637 . . . . . . . . . . . . . . . . . . . . . . . . . . 135<br />

N6000968 . . . . . . . . . . . . . . . . . . . . . . . . . . 131<br />

N6000981 . . . . . . . . . . . . . . . . . . . . . . . . . . 135<br />

N6001204 . . . . . . . . . . . . . . . . . . . . . . 132-133<br />

N6003057 . . . . . . . . . . . . . . . . . . . . . . . . . . 135<br />

N6003066 . . . . . . . . . . . . . . . . . . . . . . . . . . 135<br />

N6100016 . . . . . . . . . . . . . . . . . . . . . . . . . . 134<br />

N6100037 . . . . . . . . . . . . . . . . . . . . . . . . . . 133<br />

N6100038 . . . . . . . . . . . . . . . . . . . . . . 133, 139<br />

N6100047 . . . . . . . . . . . . . . . . . . . . . . . . . . 150<br />

N6100048 . . . . . . . . . . . . . . . . . . . . . . . . . . 152<br />

N6100102 . . . . . . . . . . . . . . . . . . 134, 150, 153<br />

N6100153 . . . . . . . . . . . . . . 150, 152, 154-155<br />

N6100157 . . . . . . . . . . . . . . . . . . . . . . . . . . 150<br />

N6100158 . . . . . . . . . . . . . . . . . . . . . . . . . . 150<br />

N6100159 . . . . . . . . . . . . . . . . . . . . . . 150, 155<br />

N6100161 . . . . . . . . . . . . . . . . . . . . . . . . . . 131<br />

N6100170 . . . . . . . . . . . . . . . . . . . . . . . . . . 133<br />

N6100194 . . . . . . . . . . . . . . . . . . . . . . 132, 134<br />

N6100228 . . . . . . . . . . . . . . . . . . . . . . . . . . 139<br />

N6100243 . . . . . . . . . . . . . . . . . . . . . . . . . . 135<br />

N6100244 . . . . . . . . . . . . . . . . . . . . . . . . . . 135<br />

N6100245 . . . . . . . . . . . . . . . . . . . . . . . . . . 135<br />

N6100253 . . . . . . . . . . . . . . . . . . . . . . . . . . 139<br />

N6100256 . . . . . . . . . . . . . . . . . . . . . . . . . . 154<br />

N6100260 . . . . . . . . . . . . . . . . . . . . . . . . . . 155<br />

N6100261 . . . . . . . . . . . . . . . . . . . . . . . . . . 155<br />

N6100264 . . . . . . . . . . . . . . . . . . . . . . . . . . 135<br />

N6100275 . . . . . . . . . . . . . . . . . . . . . . 150, 155<br />

N6100289 . . . . . . . . . . . . . . . . . . . . . . . . . . 134<br />

N6100331 . . . . . . . . . . . . . . . . . . . . . . 150, 155<br />

N6100342 . . . . . . . . . . . . . . . . . . . . . . . . . . 156<br />

N6100357 . . . . . . . . . . . . . . . . . . . . . . . . . . 132<br />

N6100361 . . . . . . . . . . . . . . . . . . . . . . . . . . 132<br />

N6100364 . . . . . . . . . . . . . . . . . . . . . . . . . . 132<br />

N6100410 . . . . . . . . . . . . . . . . . . 147, 177, 183<br />

N6100411 . . . . . . . . . . . . . . . . . . . . . . . . . . 177<br />

N6100430 . . . . . . . . . . . . . . . . . . . . . . . . . . 132<br />

N6101034 . . . . . . . . . . . . . . . . . . . . . . 150, 155<br />

N6101037 . . . . . . . . . . . . . . . . . . . . . . . . . . 133<br />

N6101048 . . . . . . . . . . . . . . . . . . . . . . . . . . 152<br />

N6101050 . . . . . . . . . . . . . . . . . . . . . . . . . . 152<br />

N6101052 . . . . . . . . . . . . . . . . . . . . . . 150, 157<br />

N6101070 . . . . . . . . . . . . . . . . . . . . . . . . . . . 93<br />

N6101085 . . . . . . . . . . . . . . . . . . . . . . 132-133<br />

N6101100 . . . . . . . . . . . . . . . . . . . . . . . . . . 133<br />

N6101182 . . . . . . . . . . . . . . . . . . . . . . . . . . . 88<br />

N6101183 . . . . . . . . . . . . . . . . . . . . . . . . . . . 88<br />

N6101251 . . . . . . . . . . . . . . . . . . . . . . . 88, 161<br />

N6101252 . . . . . . . . . . . . . . . . . . . . . . . 88, 161<br />

N6101253 . . . . . . . . . . . . . . . . . . . . . . . 88, 161<br />

N6101276 . . . . . . . . . . . . . . . . . . . . . . . . . . . 89<br />

N6101297 . . . . . . . . . . . . . . . . . . . . . . . . . . 132<br />

N6101345 . . . . . . . . . . . . . . . . . . . . . . . . . . 134<br />

N6101358 . . . . . . . . . . . . . . . . . . . . . . . . . . 150<br />

N6101372 . . . . . . . . . . . . . . . . . . . . . . 150, 157<br />

N6101374 . . . . . . . . . . . . . . . . . . . . . . . . . . 150<br />

N6101375 . . . . . . . . . . . . . . . . . . . . . . . 92, 158<br />

N6101377 . . . . . . . . . . . . . . . . . . . . . . . 92, 166<br />

N6101378 . . . . . . . . . . . . . . . . . . . . . . . . . . 150<br />

N6101380 . . . . . . . . . . . . . . . . . . . . . . . 88, 161<br />

N6101390 . . . . . . . . . . . . . . . . . . . . . . . 88, 161<br />

N6101412 . . . . . . . . . . . . . . . . . . . . . . . . . . 134<br />

N6101469 . . . . . . . . . . . . . . . . . . . . . . . 88, 161<br />

N6101470 . . . . . . . . . . . . . . . . . . . . . . . 88, 161<br />

N6101473 . . . . . . . . . . . . . . . . . . . . . . . . . . 166<br />

N6101474 . . . . . . . . . . . . . . . . . . . . . . . . . . 183<br />

N6101482 . . . . . . . . . . . . . . . . . . . . . . 150, 155<br />

N6101539 . . . . . . . . . . . . . . . . . . . . . . 155, 158<br />

N6101547 . . . . . . . . . . . . . . . . . . . . . . . . . . 133<br />

N6101696 . . . . . . . . . . . . . . . . . . . . . . . . . . 140<br />

N6101702 . . . . . . . . . . . . . . . . . . . . . . . . . . 154<br />

N6101703 . . . . . . . . . . . . . . . . . . . . . . 154, 158<br />

N6101715 . . . . . . . . . . . . . . . . . . . . . . . . . . 155<br />

N6101747 . . . . . . . . . . . . . . . . . . . . . . . . . . 155<br />

N6101751 . . . . . . . . . . . . . . . . . . . . . . . . . . 155<br />

N6101760 . . . . . . . . . . . . . . . . . . . . . . . 88, 161<br />

N6102190 . . . . . . . . . . . . . . . . . . . . . . . . . . . 92<br />

N6102197 . . . . . . . . . . . . . . . . . . . . . . . . . . 180<br />

N6102351 . . . . . . . . . . . . . . . . . . . . . . . . . . 180<br />

N6102354 . . . . . . . . . . . . . . 132, 134, 150, 153<br />

N6103079 . . . . . . . . . . . . . . . . . . . . . . . . . . 156<br />

N6103080 . . . . . . . . . . . . . . . . . . . . . . . . . . 156<br />

N6103082 . . . . . . . . . . . . . . . . . . . . . . . . . . 156<br />

N6103089 . . . . . . . . . . . . . . . . . . . . . . . . . . 132<br />

N6103151 . . . . . . . . . . . . . . . . . . . . . . . . . . 132<br />

N6103167 . . . . . . . . . . . . . . . . . . . . . . . . . . 132<br />

N6103175 . . . . . . . . . . . . . . . . . . . . . . . . . . 132<br />

N6103188 . . . . . . . . . . . . . . . . . . . . . . . . . . 132<br />

N6103196 . . . . . . . . . . . . . . . . . . . . . . . . . . 156<br />

N6103225 . . . . . . . . . . . . . . . . . . . . . . . . . . 132<br />

N6120001 . . . . . . . . . . . . . . . . . . . . . . . 92, 153<br />

N6120004 . . . . . . . . . . . . . . . . . . . . . . . . . . 166<br />

N6120005 . . . . . . . . . . . . . . . . . . . . . . . . . . 166<br />

N6120006 . . . . . . . . . . . . . . . . . . . . . . 132, 141<br />

N6120007 . . . . . . . . . . . . . . . . . . . . . . . . . . 152<br />

N6120008 . . . . . . . . . . . . . . . . . . . . . . . . . . 152<br />

N6120009 . . . . . . . . . . . . . . . . . . . . . . . . . . 151<br />

Part No. Page Part No. Page Part No. Page


N6120010 – N8122126 Part Number Index<br />

Index<br />

Part Number<br />

421<br />

N6120010 . . . . . . . . . . . . . . . . . . . . . . . . . . 133<br />

N6120011 . . . . . . . . . . . . . . . . . . . . . . . . . . 131<br />

N6120012 . . . . . . . . . . . . . . . . . . . . . . . . . . 141<br />

N6120014 . . . . . . . . . . . . . . . . . . . . . . . . . . 131<br />

N6120015 . . . . . . . . . . . . . . . . . . . . . . . . . . 141<br />

N6120016 . . . . . . . . . . . . . . . . . . . . . . . . . . 160<br />

N6120017 . . . . . . . . . . . . . . . . . . . . . . . . . . 160<br />

N6120020 . . . . . . . . . . . . . . . . . . . 92, 132, 141<br />

N6120022 . . . . . . . . . . . . . . . . . . . . . . . . . . 151<br />

N6120023 . . . . . . . . . . . . . . . . . . . . . . . . . . 152<br />

N6120024 . . . . . . . . . . . . . . . . . . . . . . . . . . 133<br />

N6120025 . . . . . . . . . . . . . . . . . . . . . . . . . . 152<br />

N6120026 . . . . . . . . . . . . . . . . . . . . . . . . . . 131<br />

N6120027 . . . . . . . . . . . . . . . . . . . . . . . . . . 141<br />

N6120031 . . . . . . . . . . . . . . . . . . . . . . . . . . . 88<br />

N6120032 . . . . . . . . . . . . . . . . . . . . . . . . . . 171<br />

N6120033 . . . . . . . . . . . . . . . . . . . . . . . . . . 171<br />

N6120036 . . . . . . . . . . . . . . . . . . . . . . . . . . . 88<br />

N6120047 . . . . . . . . . . . . . . . . . . . . . . . . . . 140<br />

N6120050 . . . . . . . . . . . . . . . . . . . . . . . . . . 151<br />

N6120057 . . . . . . . . . . . . . . . . . . . . . . . . . . 140<br />

N6120059 . . . . . . . . . . . . . . . . . . 131-132, 140<br />

N6120061 . . . . . . . . . . . . . . . . . . . . . . . . . . 140<br />

N6120062 . . . . . . . . . . . . . . . . . . . . . . . . . . 140<br />

N6120070 . . . . . . . . . . . . . . . . . . . . . . . . . . 134<br />

N6120071 . . . . . . . . . . . . . . . . . . . . . . . . . . 152<br />

N6120072 . . . . . . . . . . . . . . . . . . . . . . . . . . 152<br />

N6120074 . . . . . . . . . . . . . . . . . . . . . . . . . . 155<br />

N6120075 . . . . . . . . . . . . . . . . . . . . . . . . . . 155<br />

N6120076 . . . . . . . . . . . . . . . . . . . . . . . . . . 154<br />

N6120077 . . . . . . . . . . . . . . . . . . . . . . . . . . 154<br />

N6120078 . . . . . . . . . . . . . . . . . . . . . . . . . . 160<br />

N6120080 . . . . . . . . . . . . . . . . . . . . . . . . . . 141<br />

N6120082 . . . . . . . . . . . . . . . . . . . . . . . . . . 154<br />

N6120083 . . . . . . . . . . . . . . . . . . . . . . . . . . 154<br />

N6120088 . . . . . . . . . . . . . . . . . . . . . . . . . . 135<br />

N6120089 . . . . . . . . . . . . . . . . . . . . . . . . . . 135<br />

N6120090 . . . . . . . . . . . . . . . . . . . . . . . . . . 139<br />

N6120091 . . . . . . . . . . . . . . . . . . . . . . . . . . 139<br />

N6120092 . . . . . . . . . . . . . . . . . . . . . . . . . . 139<br />

N6120093 . . . . . . . . . . . . . . . . . . . . . . . . . . 139<br />

N6120094 . . . . . . . . . . . . . . . . . . . . . . . . . . 139<br />

N6120095 . . . . . . . . . . . . . . . . . . . . . . . . . . 135<br />

N6120098 . . . . . . . . . . . . . . . . . . . . . . . . . . 154<br />

N6120100 . . . . . . . . . . . . . . . . . . . . . . . . . . 152<br />

N6120101 . . . . . . . . . . . . . . . . . . . . . . . . . . 151<br />

N6120102 . . . . . . . . . . . . . . . . . . . . . . . . . . 155<br />

N6120105 . . . . . . . . . . . . . . . . . . . . . . . . . . . 88<br />

N6120120 . . . . . . . . . . . . . . . . . . . . . . . . . . 133<br />

N6120121 . . . . . . . . . . . . . . . . . . . . . . . . . . 133<br />

N6120122 . . . . . . . . . . . . . . . . . . . . . . . . . . 131<br />

N6120123 . . . . . . . . . . . . . . . . . . . . . . . . . . 131<br />

N6120124 . . . . . . . . . . . . . . . . . . . . . . . . . . 141<br />

N6120125 . . . . . . . . . . . . . . . . . . . . . . . . . . 141<br />

N6120126 . . . . . . . . . . . . . . . . . . . . . . . . . . 139<br />

N6120127 . . . . . . . . . . . . . . . . . . . . . . . . . . 139<br />

N6120128 . . . . . . . . . . . . . . . . . . . . . . . . . . 135<br />

N6120129 . . . . . . . . . . . . . . . . . . . . . . . . . . 135<br />

N6120130 . . . . . . . . . . . . . . . . . . . . . . . . . . 140<br />

N6120131 . . . . . . . . . . . . . . . . . . . . . . . . . . 140<br />

N6120136 . . . . . . . . . . . . . . . . . . . . . . . . . . 152<br />

N6120137 . . . . . . . . . . . . . . . . . . . . . . . . . . 152<br />

N6120138 . . . . . . . . . . . . . . . . . . . . . . . . . . 151<br />

N6120139 . . . . . . . . . . . . . . . . . . . . . . . . . . 151<br />

N6120140 . . . . . . . . . . . . . . . . . . . . . . . . . . 155<br />

N6120141 . . . . . . . . . . . . . . . . . . . . . . . . . . 155<br />

N6120142 . . . . . . . . . . . . . . . . . . . . . . . . . . 154<br />

N6120143 . . . . . . . . . . . . . . . . . . . . . . . . . . 154<br />

N6120144 . . . . . . . . . . . . . . . . . . . . . . . . . . 156<br />

N6120146 . . . . . . . . . . . . . . . . . . . . . . . . . . 166<br />

N6120148 . . . . . . . . . . . . . . . . . . . . . . . . . . 166<br />

N6120149 . . . . . . . . . . . . . . . . . . . . . . . . . . 166<br />

N6120150 . . . . . . . . . . . . . . . . . . . . . . . . . . 141<br />

N6120152 . . . . . . . . . . . . . . . . . . . . . . . . . . 166<br />

N6120153 . . . . . . . . . . . . . . . . . . . . . . . . . . 166<br />

N6120154 . . . . . . . . . . . . . . . . . . . . . . . . . . 166<br />

N6120155 . . . . . . . . . . . . . . . . . . . . . . . . . . 166<br />

N6120156 . . . . . . . . . . . . . . . . . . . . . . . . . . 166<br />

N6120157 . . . . . . . . . . . . . . . . . . . . . . . . . . 166<br />

N6120158 . . . . . . . . . . . . . . . . . . . . . . . . . . 160<br />

N6120159 . . . . . . . . . . . . . . . . . . . . . . . . . . 160<br />

N6120161 . . . . . . . . . . . . . . . . . . . . . . 132, 134<br />

N6120162 . . . . . . . . . . . . . . . . . . . . . . 132-133<br />

N6120163 . . . . . . . . . . . . . . . . . . . . . . . . . . 156<br />

N6120165 . . . . . . . . . . . . . . . . . . . . . . . . . . 132<br />

N6120166 . . . . . . . . . . . . . . . . . . . . . . . . . . 132<br />

N6120167 . . . . . . . . . . . . . . . . . . . . . . . . . . 132<br />

N6120168 . . . . . . . . . . . . . . . . . . . . . . . . . . 132<br />

N6120179 . . . . . . . . . . . . . . . . . . . . . . 138, 156<br />

N6120181 . . . . . . . . . . . . . . . . . . . . . . . . . . . 88<br />

N6121000 . . . . . . . . . . . . . . . . . . . . . . . . . . 152<br />

N6121001 . . . . . . . . . . . . . . . . . . . . . . 150, 157<br />

N6121002 . . . . . . . . . . . . . . . . . . . . . . 150, 157<br />

N6121003 . . . . . . . . . . . . . . . . . . . . . . . 92, 158<br />

N6121004 . . . . . . . . . . . . . . . . . . . . . . 155, 158<br />

N6121006 . . . . . . . . . . . . . . . . . . . . . . 155, 158<br />

N6121020 . . . . . . . . . . . . . . . . . . . . . . 150, 157<br />

N6121021 . . . . . . . . . . . . . . . . . . . . . . 150, 157<br />

N6121022 . . . . . . . . . . . . . . . . . . 150, 157-158<br />

N6200119 . . . . . . . . . . . . . . . . . . . . . . . . . . 181<br />

N6200150 . . . . . . . . . . . . . . . . . . 144, 182, 184<br />

N6200200 . . . . . . . . . . . . . . . . . . . . . . . . . . 145<br />

N6200210 . . . . . . . . . . . . . . . . . . . . . . . . . . 183<br />

N6201001 . . . . . . . . . . . . . . . . . . . . . . . . . . 146<br />

N6201030 . . . . . . . . . . . . . . . . . . . . . . . . . . 146<br />

N6212407 . . . . . . . . . . . . . . . . . . . . . . . . . . 137<br />

N6300063 . . . . . . . . . . . . . . . . . . . . . . . . . . 180<br />

N6300155 . . . . . . . . . . . . . . . . . . . . . . . . . . 180<br />

N6301054 . . . . . . . . . . . . . . . . . . . . . . . . . . 183<br />

N6301107 . . . . . . . . . . . . . . . . . . . . . . . . . . 180<br />

N6301108 . . . . . . . . . . . . . . . . . . . . . . . . . . 180<br />

N6470012 . . . . . . . . . . . . . . . . . . . . . . . . . . 137<br />

N6470045 . . . . . . . . . . . . . . . . . . . . . . . . . . 137<br />

N6470070 . . . . . . . . . . . . . . . . . . . . . . . . . . 138<br />

N6470080 . . . . . . . . . . . . . . . . . . . . . . . . . . 138<br />

N6470207 . . . . . . . . . . . . . . . . . . . . . . . . . . 137<br />

N6471025 . . . . . . . . . . . . . . . . . . . . . . 137, 163<br />

N6471031 . . . . . . . . . . . . . . . . . . . . . . . . . . 137<br />

N6500123 . . . . . . . . . . . . . . . . . . . . . . . . . . 164<br />

N6500133 . . . . . . . . . . . . . . . . . . . . . . . . . . 177<br />

N6502000 . . . . . . . . . . . . . . . . . . . . . . . . . . 158<br />

N6502001 . . . . . . . . . . . . . . . . . . . . . . 157-158<br />

N6502002 . . . . . . . . . . . . . . . . . . . . . . . . . . 158<br />

N6502003 . . . . . . . . . . . . . . . . . . . . . . . . . . 157<br />

N6502004 . . . . . . . . . . . . . . . . . . . . . . . . . . 157<br />

N6502005 . . . . . . . . . . . . . . . . . . . . . . . . . . 157<br />

N6502006 . . . . . . . . . . . . . . . . . . . . . . . . . . 157<br />

N6502009 . . . . . . . . . . . . . . . . . . . . . . . . . . 157<br />

N6502010 . . . . . . . . . . . . . . . . . . . . . . . . . . 157<br />

N6502011 . . . . . . . . . . . . . . . . . . . . . . . . . . 157<br />

N6502012 . . . . . . . . . . . . . . . . . . . . . . . . . . 157<br />

N6502013 . . . . . . . . . . . . . . . . . . . . . . . . . . 158<br />

N6502014 . . . . . . . . . . . . . . . . . . . . . . . . . . 158<br />

N6502015 . . . . . . . . . . . . . . . . . . . . . . . . . . 158<br />

N6502016 . . . . . . . . . . . . . . . . . . . . . . . . . . 158<br />

N6502017 . . . . . . . . . . . . . . . . . . . . . . . . . . 158<br />

N6513010 . . . . . . . . . . . . . . . . . . . . . . . . . . 174<br />

N6513020 . . . . . . . . . . . . . . . . . . . . . . . . . . 174<br />

N6513040 . . . . . . . . . . . . . . . . . . . . . . . . . . 175<br />

N6513060 . . . . . . . . . . . . . . . . . . . . . . . . . . 174<br />

N6513070 . . . . . . . . . . . . . . . . . . . . . . . . . . 174<br />

N6520010 . . . . . . . . . . . . . . . . . . . . . . . . . . 152<br />

N6520011 . . . . . . . . . . . . . . . . . . . . . . . . . . 152<br />

N6520012 . . . . . . . . . . . . . . . . . . . . . . . . . . 151<br />

N6520013 . . . . . . . . . . . . . . . . . . . . . . . . . . 151<br />

N6520014 . . . . . . . . . . . . . . . . . . . . . . . . . . 155<br />

N6520015 . . . . . . . . . . . . . . . . . . . . . . . . . . 155<br />

N6520016 . . . . . . . . . . . . . . . . . . . . . . . . . . 152<br />

N6520017 . . . . . . . . . . . . . . . . . . . . . . . . . . 152<br />

N6520018 . . . . . . . . . . . . . . . . . . . . . . . . . . 132<br />

N6520019 . . . . . . . . . . . . . . . . . . . . . . . . . . 132<br />

N6520020 . . . . . . . . . . . . . . . . . . . . . . . . . . 131<br />

N6520021 . . . . . . . . . . . . . . . . . . . . . . . . . . 131<br />

N6520022 . . . . . . . . . . . . . . . . . . . . . . . . . . 141<br />

N6520023 . . . . . . . . . . . . . . . . . . . . . . . . . . 141<br />

N6520024 . . . . . . . . . . . . . . . . . . . . . . . . . . 139<br />

N6520025 . . . . . . . . . . . . . . . . . . . . . . . . . . 139<br />

N6520026 . . . . . . . . . . . . . . . . . . . . . . . . . . 140<br />

N6520027 . . . . . . . . . . . . . . . . . . . . . . . . . . 140<br />

N6520028 . . . . . . . . . . . . . . . . . . . . . . . . . . 135<br />

N6520029 . . . . . . . . . . . . . . . . . . . . . . . . . . 135<br />

N6520206 . . . . . . . . . . . . . . . . . . . . . . . . . . 138<br />

N6520220 . . . . . . . . . . . . . . . . . . . . . . . . . . 138<br />

N6520235 . . . . . . . . . . . . . . . . . . . . . . . . . . 175<br />

N6520240 . . . . . . . . . . . . . . . . . . . . . . . . . . 138<br />

N6609060 . . . . . . . . . . . . . . . . . . . . . . . . . . 180<br />

N6620065 . . . . . . . . . . . . . . . . . . . . . . . . . . 149<br />

N6621006 . . . . . . . . . . . . . . . . . . . 90, 149, 272<br />

N6621008 . . . . . . . . . . . . . . . . . . . 90, 149, 272<br />

N6621009 . . . . . . . . . . . . . . . . . . . 90, 149, 272<br />

N6621028 . . . . . . . . . . 150, 152, 154-155, 159<br />

N6700113 . . . . . . . . . . . . . . . . . . . . . . . . . . 147<br />

N6700130 . . . . . . . . . . . . . . . . . . . . . . . . . . 147<br />

N6700200 . . . . . . . . . . . . . . . . . . . . . . . . . . 145<br />

N8102011 . . . . . . . . . . . . . . . . . . . . . . . . . . 196<br />

N8120100 . . . . . . . . . . . . . . . . . . . . . . 193, 195<br />

N8120113 . . . . . . . . . . . . . . . . . . . . . . . . . . 189<br />

N8120116 . . . . . . . . . . . . . . . . . . . . . . 193, 195<br />

N8120119 . . . . . . . . . . . . . . . . . . . . . . . . . . 188<br />

N8120124 . . . . . . . . . . . . . . . . . . . . . . 201, 204<br />

N8120140 . . . . . . . . . . . . . . . . . . . . . . 199, 221<br />

N8120141 . . . . . . . . . . . . . . . . . . . . . . 199, 221<br />

N8120150 . . . . . . . . . . . . . . . . . . . . . . . . . . 203<br />

N8120161 . . . . . . . . . . . . . . . . . . . . . . . . . . 191<br />

N8120180 . . . . . . . . . . . . . . . . . . . . . . . . . . 202<br />

N8120181 . . . . . . . . . . . . . . . . . . . . . . . . . . 202<br />

N8120191 . . . . . . . . . . . . . . . . . . . . . . . . . . 207<br />

N8120192 . . . . . . . . . . . . . . . . . . . . . . . . . . 207<br />

N8120503 . . . . . . . . . . . . . . . . . . . . . . . . . . 191<br />

N8120509 . . . . . . . . . . . . . . . . . . . . . . . . . . 193<br />

N8120511 . . . . . . . . . . . . . . . . . . . . . . 189, 193<br />

N8120512 . . . . . . . . . . . . . . . . . . . . . . 189, 193<br />

N8120515 . . . . . . . . . . . . . . . . . . 193, 197-198<br />

N8120516 . . . . . . . . . . . . . . . . . . . . . . 197, 201<br />

N8120522 . . . . . . . . . . . . . . . . . . . . . . . . . . 210<br />

N8120532 . . . . . . . . . . . . . . . . . . . . . . . . . . 208<br />

N8120534 . . . . . . . . . . . . . . . . . . . . . . . . . . 208<br />

N8120541 . . . . . . . . . . . . . . . . . . . . . . . . . . 210<br />

N8120542 . . . . . . . . . . . . . . . . . . . . . . . . . . 193<br />

N8122000 . . . . . . . . . . . . . . . . . . . . . . . . . . 189<br />

N8122002 . . . . . . . . . . . . . . . . . . . . . . . . . . 189<br />

N8122003 . . . . . . . . . . . . . . . . . . . . . . . . . . 189<br />

N8122004 . . . . . . . . . . . . . . . . . . . . . . . . . . 192<br />

N8122006 . . . . . . . . . . . . . . . . . . . . . . 193, 205<br />

N8122007 . . . . . . . . . . . . . . . . . . . . . . 195, 201<br />

N8122010 . . . . . . . . . . . . . . . . . . . . . . . . . . 193<br />

N8122012 . . . . . . . . . . . . . . . . . . . . . . 193, 199<br />

N8122014 . . . . . . . . . . . . . . . . . . . . . . . . . . 211<br />

N8122017 . . . . . . . . . . . . . . . . . . . . . . . . . . 210<br />

N8122025 . . . . . . . . . . . . . . . . . . . . . . . . . . 189<br />

N8122035 . . . . . . . . . . . . . . . . . . . . . . . . . . 189<br />

N8122038 . . . . . . . . . . . . . . . . . . . . . . 210, 212<br />

N8122040 . . . . . . . . . . . . . . . . . . . . . . . . . . 189<br />

N8122114 . . . . . . . . . . . . . . . . . . . . . . . . . . 189<br />

N8122118 . . . . . . . . . . . . . . . . . . . . . . . . . . 200<br />

N8122126 . . . . . . . . . . . . . . . . . . . . . . 199, 224<br />

Part No. Page Part No. Page Part No. Page<br />

See page 4 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

See page 2 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong>


Index Part Number N8122127 – N9300232<br />

Index<br />

Part Number<br />

422<br />

N8122127 . . . . . . . . . . . . . . . . . . . . . . . . . . 199<br />

N8122132 . . . . . . . . . . . . . . . . . . . . . . . . . . 200<br />

N8122150 . . . . . . . . . . . . . . . . . . . . . . 199, 221<br />

N8122161 . . . . . . . . . . . . . . . . . . . . . . 199, 221<br />

N8122162 . . . . . . . . . . . . . . . . . . . . . . 199, 221<br />

N8122170 . . . . . . . . . . . . . . . . . . . . . . . . . . 188<br />

N8122188 . . . . . . . . . . . . . . . . . . . . . . 203, 225<br />

N8122192 . . . . . . . . . . . . . . . . . . . . . . . . . . 196<br />

N8122193 . . . . . . . . . . . . . . . . . . . . . . . . . . 190<br />

N8122194 . . . . . . . . . . . . . . . . . . . . . . . . . . 190<br />

N8122239 . . . . . . . . . . . . . . . . . . . . . . 198, 223<br />

N8122247 . . . . . . . . . . . . . . . . . . . . . . . . . . 189<br />

N8122248 . . . . . . . . . . . . . . . . . . . . . . . . . . 189<br />

N8122249 . . . . . . . . . . . . . . . . . . . . . . . . . . 208<br />

N8122250 . . . . . . . . . . . . . . . . . . . . . . . . . . 208<br />

N8122251 . . . . . . . . . . . . . . . . . . . . . . . . . . 208<br />

N8122252 . . . . . . . . . . . . . . . . . . . . . . . . . . 199<br />

N8122254 . . . . . . . . . . . . . . . . . . . . . . . . . . 208<br />

N8122256 . . . . . . . . . . . . . . . . . . . . . . . . . . 208<br />

N8122258 . . . . . . . . . . . . . . . . . . . . . . . . . . 208<br />

N8122308 . . . . . . . . . . . . . . . . . . . . . . 192-193<br />

N8122340 . . . . . . . . . . . . . . . . . . . . . . . . . . 198<br />

N8122341 . . . . . . . . . . . . . . . . . . . . . . . . . . 198<br />

N8122350 . . . . . . . . . . . . . . . . . . . . . . . . . . 196<br />

N8122351 . . . . . . . . . . . . . . . . . . . . . . . . . . 196<br />

N8122355 . . . . . . . . . . . . . . . . . . . . . . . . . . 188<br />

N8122356 . . . . . . . . . . . . . . . . . . . . . . . . . . 204<br />

N8122357 . . . . . . . . . . . . . . . . . . . . . . 197, 204<br />

N8122358 . . . . . . . . . . . . . . . . . . . . . . . . . . 194<br />

N8122359 . . . . . . . . . . . . . . . . . . . . . . . . . . 194<br />

N8122360 . . . . . . . . . . . . . . . . . . . . . . . . . . 188<br />

N8122361 . . . . . . . . . . . . . . . . . . . . . . . . . . 188<br />

N8122362 . . . . . . . . . . . . . . . . . . . . . . . . . . 200<br />

N8122363 . . . . . . . . . . . . . . . . . . . . . . . . . . 200<br />

N8122383 . . . . . . . . . . . . . . . . . . . . . . . . . . 196<br />

N8122384 . . . . . . . . . . . . . . . . . . . . . . . . . . 196<br />

N8122385 . . . . . . . . . . . . . . . . . . . . . . . . . . 192<br />

N8122387 . . . . . . . . . . . . . . . . . . . . . . . . . . 192<br />

N8122388 . . . . . . . . . . . . . . . . . . . . . . . . . . 192<br />

N8122389 . . . . . . . . . . . . . . . . . . . . . . . . . . 200<br />

N8122394 . . . . . . . . . . . . . . . . . . . . . . . . . . 194<br />

N8122410 . . . . . . . . . . . . . . . . . . . . . . . . . . 200<br />

N8122411 . . . . . . . . . . . . . . . . . . . . . . . . . . 194<br />

N8122412 . . . . . . . . . . . . . . . . . . . . . . . . . . 194<br />

N8122413 . . . . . . . . . . . . . . . . . . . . . . . . . . 194<br />

N8122414 . . . . . . . . . . . . . . . . . . . . . . . . . . 200<br />

N8122415 . . . . . . . . . . . . . . . . . . . . . . . . . . 200<br />

N8125001 . . . . . . . . . . . . . . . . . . . . . . 190, 193<br />

N8125003 . . . . . . . . . . . . . . . . . . . . . . . . . . 199<br />

N8125006 . . . . . . . . . . . . . . . . . . . . . . . . . . 193<br />

N8125029 . . . . . . . . . . . . . . . . . . . . . . . . . . 195<br />

N8125030 . . . . . . . . . . . . . . . . . . . . . . . . . . 210<br />

N8125031 . . . . . . . . . . . . . . . . . . . . . . . . . . 210<br />

N8125032 . . . . . . . . . . . . . . . . . . . . . . . . . . 210<br />

N8125033 . . . . . . . . . . . . . . . . . . . . . . 210, 212<br />

N8125034 . . . . . . . . . . . . . . . . . . . . . . . . . . 210<br />

N8125035 . . . . . . . . . . . . . . . . . . . . . . . . . . 210<br />

N8125037 . . . . . . . . . . . . . . . . . . . . . . 210, 212<br />

N8125038 . . . . . . . . . . . . . . . . . . . . . . 210, 212<br />

N8125039 . . . . . . . . . . . . . . . . . . . . . . . . . . 212<br />

N8125040 . . . . . . . . . . . . . . . . . . . . . . . . . . 212<br />

N8125041 . . . . . . . . . . . . . . . . . . . . . . . . . . 212<br />

N8126039 . . . . . . . . . . . . . . . . . . . . . . . . . . 194<br />

N8126040 . . . . . . . . . . . . . . . . . . . . . . . . . . 194<br />

N8126041 . . . . . . . . . . . . . . . . . . . . . . 193-194<br />

N9300030 . . . . . . . . . . . . . . . . . . . . . . . . . . . 95<br />

N9300031 . . . . . . . . . . . . . . . . . . . . . . . . . . . 95<br />

N9300032 . . . . . . . . . . . . . . . . . . . . . . . . . . . 95<br />

N9300033 . . . . . . . . . . . . . . . . . . . . . . . . . . . 95<br />

N9300036 . . . . . . . . . . . . . . . . . . . . . . . . . . . 95<br />

N9300037 . . . . . . . . . . . . . . . . . . . . . . . . . . . 95<br />

N9300038 . . . . . . . . . . . . . . . . . . . . . . . . . . . 95<br />

N9300039 . . . . . . . . . . . . . . . . . . . . . . . . . . . 95<br />

N9300040 . . . . . . . . . . . . . . . . . . . . . . . . . . . 95<br />

N9300041 . . . . . . . . . . . . . . . . . . . . . . . . . . . 95<br />

N9300042 . . . . . . . . . . . . . . . . . . . . . . . . . . . 95<br />

N9300043 . . . . . . . . . . . . . . . . . . . . . . . . . . . 95<br />

N9300044 . . . . . . . . . . . . . . . . . . . . . . . . . . . 95<br />

N9300046 . . . . . . . . . . . . . . . . . . . . . . . . . . . 95<br />

N9300047 . . . . . . . . . . . . . . . . . . . . . . . . . . . 95<br />

N9300048 . . . . . . . . . . . . . . . . . . . . . . . . . . . 95<br />

N9300049 . . . . . . . . . . . . . . . . . . . . . . . . . . . 95<br />

N9300050 . . . . . . . . . . . . . . . . . . . . . . . . . . . 95<br />

N9300051 . . . . . . . . . . . . . . . . . . . . . . . . . . . 95<br />

N9300053 . . . . . . . . . . . . . . . . . . . . . . . . . . . 95<br />

N9300054 . . . . . . . . . . . . . . . . . . . . . . . . . . . 95<br />

N9300055 . . . . . . . . . . . . . . . . . . . . . . . 95, 150<br />

N9300056 . . . . . . . . . . . . . . . . . . . . . . . 95, 150<br />

N9300057 . . . . . . . . . . . . . . . . . . . . . . . . . . . 95<br />

N9300058 . . . . . . . . . . . . . . . . . . . . . . . . . . . 95<br />

N9300059 . . . . . . . . . . . . . . . . . . . . . . . 95, 147<br />

N9300060 . . . . . . . . . . . . . . . . . . . . . . . . . . . 95<br />

N9300061 . . . . . . . . . . . . . . . . . . . . . . . . . . . 95<br />

N9300063 . . . . . . . . . . . . . . . . . . . . . . . . . . . 92<br />

N9300065 . . . . . . . . . . . . . . . . . . . . . . . . . . . 17<br />

N9300066 . . . . . . . . . . . . . . . . . . . . . . . . . . . 17<br />

N9300067 . . . . . . . . . . . . . . . . . . . . . . 197, 223<br />

N9300068 . . . . . . . . . . . . . . . . . . . . . . . . . . . 37<br />

N9300077 . . . . . . . . . . . . . . . . . . . . . . 137, 167<br />

N9300081 . . . . . . . . . . . . . . . . . . . . . . . . . . 167<br />

N9300086 . . . . . . . . . . . . . . . . . . . . . . . . . . 257<br />

N9300087 . . . . . . . . . . . . . . . . . . . . . . . . . . 171<br />

N9300088 . . . . . . . . . . . . . . . . . . . . . . . . . . 170<br />

N9300089 . . . . . . . . . . . . . . . . . . . . . . . . . . 133<br />

N9300090 . . . . . . . . . . . . . . . . . . . . . . . . . . 170<br />

N9300096 . . . . . . . . . . . . . . . . . . . . . . . . . . 135<br />

N9300100 . . . . . . . . . . . . . . . . . . . . . . . . . . . 68<br />

N9300101 . . . . . . . . . . . . . . . . . . . . 66, 68, 234<br />

N9300102 . . . . . . . . . . . . . . . . . . . . . . . . . . . 68<br />

N9300103 . . . . . . . . . . . . . . . . . . . . . . . . . . . 68<br />

N9300104 . . . . . . . . . . . . . . . . . . . . . . . . . . . 68<br />

N9300105 . . . . . . . . . . . . . . . . . . . . . . . . . . . 68<br />

N9300106 . . . . . . . . . . . . . . . . . . . . . . . . . . . 68<br />

N9300107 . . . . . . . . . . . . . . . . . . . . . . . . . . . 68<br />

N9300108 . . . . . . . . . . . . . . . . . . . . . . . . . . . 68<br />

N9300110 . . . . . . . . . . . . . . . . . . . . . . . . . . . 68<br />

N9300111 . . . . . . . . . . . . . . . . . . . . . . . . . . . 68<br />

N9300112 . . . . . . . . . . . . . . . . . . . . . . . . . . . 68<br />

N9300113 . . . . . . . . . . . . . . . . . . . . . . . . . . . 68<br />

N9300114 . . . . . . . . . . . . . . . . . . . . . . . . . . . 68<br />

N9300115 . . . . . . . . . . . . . . . . . . . . . . . . . . . 68<br />

N9300116 . . . . . . . . . . . . . . . . . . . . . . . . . . . 68<br />

N9300117 . . . . . . . . . . . . . . . . . . . . . . . . . . . 68<br />

N9300118 . . . . . . . . . . . . . . . . . . . . . . . . . . . 68<br />

N9300119 . . . . . . . . . . . . . . . . . . . . . . . . . . . 68<br />

N9300120 . . . . . . . . . . . . . . . . . . . . . . . . . . . 68<br />

N9300121 . . . . . . . . . . . . . . . . . . . . . . . . . . . 68<br />

N9300122 . . . . . . . . . . . . . . . . . . . . . . . . . . . 68<br />

N9300123 . . . . . . . . . . . . . . . . . . . . . . . . . . . 68<br />

N9300124 . . . . . . . . . . . . . . . . . . . . . . . . . . . 68<br />

N9300125 . . . . . . . . . . . . . . . . . . . . . . . . . . . 68<br />

N9300126 . . . . . . . . . . . . . . . . . . . . . . . . . . . 68<br />

N9300127 . . . . . . . . . . . . . . . . . . . . . . . . . . . 68<br />

N9300128 . . . . . . . . . . . . . . . . . . . . . . . . . . . 68<br />

N9300129 . . . . . . . . . . . . . . . . . . . . . . . . . . . 68<br />

N9300130 . . . . . . . . . . . . . . . . . . . . . . . . . . . 68<br />

N9300131 . . . . . . . . . . . . . . . . . . . . . . . . . . . 68<br />

N9300132 . . . . . . . . . . . . . . . . . . . . . . . . . . . 68<br />

N9300133 . . . . . . . . . . . . . . . . . . . . . . . . 66, 68<br />

N9300134 . . . . . . . . . . . . . . . . . . . . . . . . . . . 69<br />

N9300135 . . . . . . . . . . . . . . . . . . . . . . . . . . . 69<br />

N9300136 . . . . . . . . . . . . . . . . . . . . . . . . . . . 69<br />

N9300137 . . . . . . . . . . . . . . . . . . . . . . . . . . . 69<br />

N9300138 . . . . . . . . . . . . . . . . . . . . . . . . . . . 69<br />

N9300139 . . . . . . . . . . . . . . . . . . . . . . . . . . . 69<br />

N9300140 . . . . . . . . . . . . . . . . . . . . . . . . . . . 69<br />

N9300141 . . . . . . . . . . . . . . . . . . . . . . . . . . . 69<br />

N9300142 . . . . . . . . . . . . . . . . . . . . . . . . . . . 69<br />

N9300143 . . . . . . . . . . . . . . . . . . . . . . . . . . . 69<br />

N9300144 . . . . . . . . . . . . . . . . . . . . . . . . . . . 69<br />

N9300145 . . . . . . . . . . . . . . . . . . . . . . . . . . . 69<br />

N9300146 . . . . . . . . . . . . . . . . . . . . . . . . . . . 69<br />

N9300147 . . . . . . . . . . . . . . . . . . . . . . . . . . . 69<br />

N9300148 . . . . . . . . . . . . . . . . . . . . . . . . . . . 69<br />

N9300149 . . . . . . . . . . . . . . . . . . . . . . . . . . . 69<br />

N9300150 . . . . . . . . . . . . . . . . . . . . . . . . . . . 69<br />

N9300151 . . . . . . . . . . . . . . . . . . . . . . . . . . . 69<br />

N9300152 . . . . . . . . . . . . . . . . . . . . . . . . . . . 69<br />

N9300153 . . . . . . . . . . . . . . . . . . . . . . . . . . . 69<br />

N9300154 . . . . . . . . . . . . . . . . . . . . . . . . . . . 69<br />

N9300155 . . . . . . . . . . . . . . . . . . . . . . . . . . . 69<br />

N9300156 . . . . . . . . . . . . . . . . . . . . . . . . . . . 69<br />

N9300157 . . . . . . . . . . . . . . . . . . . . . . . . . . . 69<br />

N9300158 . . . . . . . . . . . . . . . . . . . . . . . . . . . 69<br />

N9300160 . . . . . . . . . . . . . . . . . . . . . . . . . . . 69<br />

N9300161 . . . . . . . . . . . . . . . . . . . . . . . . . . . 69<br />

N9300162 . . . . . . . . . . . . . . . . . . . . . . . . . . . 69<br />

N9300163 . . . . . . . . . . . . . . . . . . . . . . . . . . . 69<br />

N9300165 . . . . . . . . . . . . . . . . . . . . . . . . . . . 69<br />

N9300166 . . . . . . . . . . . . . . . . . . . . . . . . . . . 69<br />

N9300167 . . . . . . . . . . . . . . . . . . . . . . . . . . . 69<br />

N9300168 . . . . . . . . . . . . . . . . . . . . . . . . . . . 69<br />

N9300169 . . . . . . . . . . . . . . . . . . . . . . . . . . . 69<br />

N9300170 . . . . . . . . . . . . . . . . . . . . . . . . . . . 69<br />

N9300171 . . . . . . . . . . . . . . . . . . . . . . . . . . . 69<br />

N9300172 . . . . . . . . . . . . . . . . . . . . . . . . . . . 68<br />

N9300173 . . . . . . . . . . . . . . . . . . . . . . . . . . . 68<br />

N9300174 . . . . . . . . . . . . . . . . . . . . . . . . . . . 68<br />

N9300175 . . . . . . . . . . . . . . . . . . . . . . . . . . . 68<br />

N9300176 . . . . . . . . . . . . . . . . . . . . . . . . . . . 68<br />

N9300177 . . . . . . . . . . . . . . . . . . . . . . . . . . . 69<br />

N9300178 . . . . . . . . . . . . . . . . . . . . . . . . . . . 69<br />

N9300179 . . . . . . . . . . . . . . . . . . . . . . . . . . . 68<br />

N9300180 . . . . . . . . . . . . . . . . . . . . . . . . . . . 68<br />

N9300181 . . . . . . . . . . . . . . . . . . . . . . . . . . . 68<br />

N9300182 . . . . . . . . . . . . . . . . . . . . . . . . . . . 69<br />

N9300183 . . . . . . . . . . . . . . . . . . . . . . . . . . . 68<br />

N9300184 . . . . . . . . . . . . . . . . . . . . . . . . . . . 68<br />

N9300200 . . . . . . . . . . . . . . . . . . . . . . . . . . 234<br />

N9300201 . . . . . . . . . . . . . . . . . . . . . . . . . . 234<br />

N9300202 . . . . . . . . . . . . . . . . . . . . . . . . . . 234<br />

N9300203 . . . . . . . . . . . . . . . . . . . . . . . . . . 235<br />

N9300204 . . . . . . . . . . . . . . . . . . . . . . . . . . 235<br />

N9300205 . . . . . . . . . . . . . . . . . . . . . . . . . . 234<br />

N9300207 . . . . . . . . . . . . . . . . . . . . . . . . . . . 68<br />

N9300208 . . . . . . . . . . . . . . . . . . . . . . . . . . 234<br />

N9300211 . . . . . . . . . . . . . . . . . . . . . . . 67, 233<br />

N9300212 . . . . . . . . . . . . . . . . . . . . . . . 67, 233<br />

N9300213 . . . . . . . . . . . . . . . . . . . . . . . 67, 233<br />

N9300214 . . . . . . . . . . . . . . . . . . . . . . . 66, 232<br />

N9300215 . . . . . . . . . . . . . . . . . . . . . . . 66, 232<br />

N9300216 . . . . . . . . . . . . . . . . . . . . . . . . . . 232<br />

N9300217 . . . . . . . . . . . . . . . . . . . . . . . . . . 232<br />

N9300218 . . . . . . . . . . . . . . . . . . . . . . . . . . . 66<br />

N9300219 . . . . . . . . . . . . . . . . . . . . . . . . . . . 66<br />

N9300220 . . . . . . . . . . . . . . . . . . . . . . . . . . . 66<br />

N9300221 . . . . . . . . . . . . . . . . . . . . . . . . . . . 66<br />

N9300224 . . . . . . . . . . . . . . . . . . . . . . . . . . . 67<br />

N9300225 . . . . . . . . . . . . . . . . . . . . . . . . . . 232<br />

N9300226 . . . . . . . . . . . . . . . . . . . . . . . . . . 233<br />

N9300227 . . . . . . . . . . . . . . . . . . . . . . . . . . 233<br />

N9300228 . . . . . . . . . . . . . . . . . . . . . . . . . . 233<br />

N9300229 . . . . . . . . . . . . . . . . . . . . . . . . . . 234<br />

N9300230 . . . . . . . . . . . . . . . . . . . . . . . . . . 234<br />

N9300231 . . . . . . . . . . . . . . . . . . . . . . . . . . 211<br />

N9300232 . . . . . . . . . . . . . . . . . . . . . . . . . . 211<br />

Part No. Page Part No. Page Part No. Page


N9300233 – N9302846 Part Number Index<br />

Index<br />

Part Number<br />

423<br />

N9300233 . . . . . . . . . . . . . . . . . . . . . . . . . . 211<br />

N9300234 . . . . . . . . . . . . . . . . . . . . . . . . . . 211<br />

N9300235 . . . . . . . . . . . . . . . . . . . . . . . . . . 212<br />

N9300241 . . . . . . . . . . . . . . . . . . . . . . . . . . 235<br />

N9300244 . . . . . . . . . . . . . . . . . . . . . . . . . . . 66<br />

N9300260 . . . . . . . . . . . . . . . . . . . . . . . . . . . 67<br />

N9300280 . . . . . . . . . . . . . . . . . . . . . . . . . . 235<br />

N9300281 . . . . . . . . . . . . . . . . . . . . . . . . . . 235<br />

N9301001 . . . . . . . . . . . . . . . . . . . . . . . . . . 323<br />

N9301002 . . . . . . . . . . . . . . . . . . . . . . . . . . 323<br />

N9301029 . . . . . . . . . . . . . . . . . . . . . . . . . . 327<br />

N9301063 . . . . . . . . . . . . . . . . . . . . . . . . . . 327<br />

N9301067 . . . . . . . . . . . . . . . . . . . . . . . . . . 327<br />

N9301068 . . . . . . . . . . . . . . . . . . . . . . . . . . 327<br />

N9301167 . . . . . . . . . . . . . . . . . . . . . . . . . . . 93<br />

N9301169 . . . . . . . . . . . . . . . . . . . . . . . . . . . 93<br />

N9301170 . . . . . . . . . . . . . . . . . . . . . . . . . . . 93<br />

N9301171 . . . . . . . . . . . . . . . . . . . . . . . . . . . 93<br />

N9301172 . . . . . . . . . . . . . . . . . . . . . . . . . . . 93<br />

N9301176 . . . . . . . . . . . . . . . . . . 163, 354, 367<br />

N9301177 . . . . . . . . . . . . . . . . . . . . . . . . . . 163<br />

N9301178 . . . . . . . . . . . . . . . . . . 163, 354, 367<br />

N9301179 . . . . . . . . . . . . . . . . . . . . . . . . . . 163<br />

N9301191 . . . . . . . . . . . . . . . . . . . . . . . . . . 163<br />

N9301192 . . . . . . . . . . . . . . . . . . . . . . . . . . 163<br />

N9301193 . . . . . . . . . . . . . . . . . . . . . . . . . . 163<br />

N9301204 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8<br />

N9301205 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8<br />

N9301221 . . . . . . . . . . . . . . . . . . . . . . . . . . . 95<br />

N9301222 . . . . . . . . . . . . . . . . . . . . . . . . . . . 95<br />

N9301223 . . . . . . . . . . . . . . . . . . . . . . . . . . . 95<br />

N9301225 . . . . . . . . . . . . . . . . . . . . . . . . . . . 95<br />

N9301226 . . . . . . . . . . . . . . . . . . . . . . . . . . . 95<br />

N9301227 . . . . . . . . . . . . . . . . . . . . . . . . . . . 95<br />

N9301233 . . . . . . . . . . . . . . . . . . . . . . . . . . . 95<br />

N9301253 . . . . . . . . . . . . . . . . . . . . . . . . . . . 95<br />

N9301254 . . . . . . . . . . . . . . . . . . . . . . . . . . . 95<br />

N9301255 . . . . . . . . . . . . . . . . . . . . . . . . . . . 95<br />

N9301259 . . . . . . . . . . . . . . . . . . . . . . . . . . . 95<br />

N9301266 . . . . . . . . . . . . . . . . . . . . . . . . . . . 95<br />

N9301267 . . . . . . . . . . . . . . . . . . . . . . . . . . . 95<br />

N9301268 . . . . . . . . . . . . . . . . . . . . . . . . . . . 95<br />

N9301269 . . . . . . . . . . . . . . . . . . . . . . . . . . . 95<br />

N9301270 . . . . . . . . . . . . . . . . . . . 90, 149, 272<br />

N9301272 . . . . . . . . . . . . . . . . . . . . . . 132, 137<br />

N9301298 . . . . . . . . . . . . . . . . . . . . . . 165, 354<br />

N9301299 . . . . . . . . . . . . . . . . . . . . . . 165, 354<br />

N9301303 . . . . . . . . . . . . . . . . . . . . . . . . . . . 89<br />

N9301304 . . . . . . . . . . . . . . . . . . . . . . . . . . . 89<br />

N9301324 . . . . . . . . . . . . . . . . . . . . . . 167, 354<br />

N9301325 . . . . . . . . . . . . . . . . . . . . . . . . . . 167<br />

N9301327 . . . . . . . . . . . . . . . . . . . . . . . . . . 167<br />

N9301328 . . . . . . . . . . . . . . . . . . . . . . . . . . 167<br />

N9301338 . . . . . . . . . . . . . . . . . . . . . . . . . . . 93<br />

N9301340 . . . . . . . . . . . . . . . . . . . . . . . . . . . 93<br />

N9301341 . . . . . . . . . . . . . . . . . . . . . . . . . . . 93<br />

N9301342 . . . . . . . . . . . . . . . . . . . . . . . . . . . 93<br />

N9301343 . . . . . . . . . . . . . . . . . . . . . . . . . . . 93<br />

N9301346 . . . . . . . . . . . . . . . . . . . . . . . . . . . 93<br />

N9301354 . . . . . . . . . . . . . . . . . . . . . . . . . . . 93<br />

N9301355 . . . . . . . . . . . . . . . . . . . . . . . 93, 180<br />

N9301356 . . . . . . . . . . . . . . . . . . . 93, 144, 147<br />

N9301357 . . . . . . . . . . . . . . . . . . . 93, 144, 147<br />

N9301358 . . . . . . . . . . . . . . . . . . . . . . . . . . . 93<br />

N9301360 . . . . . . . . . . . . . . . . . . . . . . . . . . . 94<br />

N9301361 . . . . . . . . . . . . . . . . . . . . . . . . . . . 94<br />

N9301376 . . . . . . . . . . . . . . . . . . . 92, 132, 137<br />

N9301385 . . . . . . . . . . . . . . . . . . . . . . . 89, 271<br />

N9301390 . . . . . . . . . . . . . . . . . . . . . . . . . . . 90<br />

N9301398 . . . . . . . . . . . . . . . . . . . . . . . . . . . 36<br />

N9301399 . . . . . . . . . . . . . . . . . . . . . . . . . . . 36<br />

N9301710 . . . . . . . . . . . . . . . . . . . . . . . . . . . 36<br />

N9301711 . . . . . . . . . . . . . . . . . . . . . . . . . . . 36<br />

N9301712 . . . . . . . . . . . . . . . . . . . . . . . . . . . 36<br />

N9301714 . . . . . . . . . . . . . . . . . . . . . . . . . . . 36<br />

N9301715 . . . . . . . . . . . . . . . . . . . . . . . . . . . 36<br />

N9301720 . . . . . . . . . . . . . . . . . . . . . . . . . . 211<br />

N9301730 . . . . . . . . . . . . . . . . . . . . . . . . . . 137<br />

N9302081 . . . . . . . . . . . . . . . . . . . . . . . . . . . 94<br />

N9302130 . . . . . . . . . . . . . . . . . . . . . . . . . . 208<br />

N9302134 . . . . . . . . . . . . . . . . . . . . . . . . . . 271<br />

N9302136 . . . . . . . . . . . . . . . . . . . . . . . . . . 271<br />

N9302141 . . . . . . . . . . . . . . . . . . . . . . . . . . 271<br />

N9302143 . . . . . . . . . . . . . . . . . . . . . . . . . . 271<br />

N9302145 . . . . . . . . . . . . . . . . . . . . . . . . . . 166<br />

N9302146 . . . . . . . . . . . . . . . . . . . . . . . . . . 166<br />

N9302149 . . . . . . . . . . . . . . . . . . . . . . . . . . . 93<br />

N9302197 . . . . . . . . . . . . . . . . . . . . . . . . . . . 36<br />

N9302199 . . . . . . . . . . . . . . . . . . . . . . . . . . . 36<br />

N9302202 . . . . . . . . . . . . . . . . . . . . . . . . . . 161<br />

N9302203 . . . . . . . . . . . . . . . . . . . . . . . . . . 161<br />

N9302204 . . . . . . . . . . . . . . . . . . . . . . . . . . 161<br />

N9302210 . . . . . . . . . . . . . . . . . . . . . . . . . . 161<br />

N9302211 . . . . . . . . . . . . . . . . . . . . . . . . . . 161<br />

N9302212 . . . . . . . . . . . . . . . . . . . . . . . . . . 161<br />

N9302213 . . . . . . . . . . . . . . . . . . . . . . . . . . 161<br />

N9302214 . . . . . . . . . . . . . . . . . . . . . . . . . . 161<br />

N9302215 . . . . . . . . . . . . . . . . . . . . . . . . . . 161<br />

N9302220 . . . . . . . . . . . . . . . . . . . . . . . . . . 162<br />

N9302222 . . . . . . . . . . . . . . . . . . . . . . . . . . 162<br />

N9302224 . . . . . . . . . . . . . . . . . . . . . . . . . . 162<br />

N9302226 . . . . . . . . . . . . . . . . . . . . . . . . . . 162<br />

N9302230 . . . . . . . . . . . . . . . . . . . . . . . . . . 161<br />

N9302231 . . . . . . . . . . . . . . . . . . . . . . . . . . 162<br />

N9302235 . . . . . . . . . . . . . . . . . . . . . . . . . . 162<br />

N9302237 . . . . . . . . . . . . . . . . . . . . . . . . . . 162<br />

N9302240 . . . . . . . . . . . . . . . . . . . . . . . . . . 162<br />

N9302241 . . . . . . . . . . . . . . . . . . . . . . . . . . 162<br />

N9302242 . . . . . . . . . . . . . . . . . . . . . . . . . . 162<br />

N9302243 . . . . . . . . . . . . . . . . . . . . . . . . . . 162<br />

N9302244 . . . . . . . . . . . . . . . . . . . . . . . . . . 162<br />

N9302245 . . . . . . . . . . . . . . . . . . . . . . . . . . 162<br />

N9302247 . . . . . . . . . . . . . . . . . . . . . . . . . . 162<br />

N9302250 . . . . . . . . . . . . . . . . . . . . . . . . . . 162<br />

N9302251 . . . . . . . . . . . . . . . . . . . . . . . . . . 162<br />

N9302253 . . . . . . . . . . . . . . . . . . . . . . . . . . 162<br />

N9302254 . . . . . . . . . . . . . . . . . . . . . . . . . . 162<br />

N9302256 . . . . . . . . . . . . . . . . . . . . . . . . . . 162<br />

N9302257 . . . . . . . . . . . . . . . . . . . . . . . . . . 162<br />

N9302259 . . . . . . . . . . . . . . . . . . . . . . . . . . 162<br />

N9302262 . . . . . . . . . . . . . . . . . . . . . . . . . . 162<br />

N9302265 . . . . . . . . . . . . . . . . . . . . . . . . . . 162<br />

N9302266 . . . . . . . . . . . . . . . . . . . . . . . . . . 162<br />

N9302560 . . . . . . . . . . . . . . . . . . . . . . . . . . 270<br />

N9302561 . . . . . . . . . . . . . . . . . . . . . . . . . . 270<br />

N9302562 . . . . . . . . . . . . . . . . . . . . . . . . . . 270<br />

N9302563 . . . . . . . . . . . . . . . . . . . . . . . . . . 270<br />

N9302564 . . . . . . . . . . . . . . . . . . . . . . . . . . 270<br />

N9302565 . . . . . . . . . . . . . . . . . . . . . . . . . . 270<br />

N9302567 . . . . . . . . . . . . . . . . . . . . . . . 90, 272<br />

N9302568 . . . . . . . . . . . . . . . . . . . . . . . . . . . 90<br />

N9302569 . . . . . . . . . . . . . . . . . . . . . . . 90, 272<br />

N9302570 . . . . . . . . . . . . . . . . . . . . . . . 90, 272<br />

N9302571 . . . . . . . . . . . . . . . . . . . . . . . . . . 149<br />

N9302572 . . . . . . . . . . . . . . . . . . . . . . . . . . 149<br />

N9302573 . . . . . . . . . . . . . . . . . . . . . . . . . . 149<br />

N9302574 . . . . . . . . . . . . . . . . . . . . . . . . . . 149<br />

N9302575 . . . . . . . . . . . . . . . . . . . . . . . 90, 272<br />

N9302576 . . . . . . . . . . . . . . . . . . . . . . . . . . . 90<br />

N9302577 . . . . . . . . . . . . . . . . . . . . . . . 90, 272<br />

N9302578 . . . . . . . . . . . . . . . . . . . . . . . . . . . 90<br />

N9302579 . . . . . . . . . . . . . . . . . . . . . . 149, 272<br />

N9302580 . . . . . . . . . . . . . . . . . . . . . . . . . . 149<br />

N9302581 . . . . . . . . . . . . . . . . . . . . . . . . . . 149<br />

N9302582 . . . . . . . . . . . . . . . . . . . . . . . . . . 149<br />

N9302585 . . . . . . . . . . . . . . . . . . . 90, 149, 272<br />

N9302600 . . . . . . . . . . . . . . . . . . . . . . . . . . 253<br />

N9302603 . . . . . . . . . . . . . . . . . . . . . . . . . . 253<br />

N9302604 . . . . . . . . . . . . . . . . . . . . . . . . . . 253<br />

N9302605 . . . . . . . . . . . . . . . . . . . . . . . . . . 253<br />

N9302606 . . . . . . . . . . . . . . . . . . . . . . . . . . 253<br />

N9302607 . . . . . . . . . . . . . . . . . . . . . . . . . . 253<br />

N9302608 . . . . . . . . . . . . . . . . . . . . . . . . . . 253<br />

N9302609 . . . . . . . . . . . . . . . . . . . . . . . . . . 253<br />

N9302610 . . . . . . . . . . . . . . . . . . . . . . . . . . 253<br />

N9302611 . . . . . . . . . . . . . . . . . . . . . . . . . . 253<br />

N9302612 . . . . . . . . . . . . . . . . . . . . . . . . . . 253<br />

N9302613 . . . . . . . . . . . . . . . . . . . . . . . . . . 253<br />

N9302614 . . . . . . . . . . . . . . . . . . . . . . . . . . 253<br />

N9302615 . . . . . . . . . . . . . . . . . . . . . . . . . . 253<br />

N9302618 . . . . . . . . . . . . . . . . . . . . . . . . . . 252<br />

N9302619 . . . . . . . . . . . . . . . . . . . . . . . . . . 253<br />

N9302620 . . . . . . . . . . . . . . . . . . . . . . . . . . 249<br />

N9302622 . . . . . . . . . . . . . . . . . . . . . . . . . . 253<br />

N9302640 . . . . . . . . . . . . . . . . . . . . . . . . . . 249<br />

N9302642 . . . . . . . . . . . . . . . . . . . . . . . . . . 250<br />

N9302643 . . . . . . . . . . . . . . . . . . . . . . . . . . 250<br />

N9302650 . . . . . . . . . . . . . . . . . . . . . . . . . . 327<br />

N9302676 . . . . . . . . . . . . . . . . . . . . . . . . . . 323<br />

N9302677 . . . . . . . . . . . . . . . . . . . . . . . . . . 325<br />

N9302678 . . . . . . . . . . . . . . . . . . . . . . . . . . 327<br />

N9302680 . . . . . . . . . . . . . . . . . . . . . . . 89, 271<br />

N9302681 . . . . . . . . . . . . . . . . . . . . . . . . . . . 89<br />

N9302682 . . . . . . . . . . . . . . . . . . . . . . . . . . . 89<br />

N9302684 . . . . . . . . . . . . . . . . . . . . . . . 89, 271<br />

N9302685 . . . . . . . . . . . . . . . . . . . . . . . 89, 271<br />

N9302686 . . . . . . . . . . . . . . . . . . . . . . . 89, 271<br />

N9302698 . . . . . . . . . . . . . . . . . . . . . . . . . . 134<br />

N9302736 . . . . . . . . . . . . . . . . . . . . . . . . . . 386<br />

N9302780 . . . . . . . . . . . . . . . . . . . . . . . . . . . 89<br />

N9302781 . . . . . . . . . . . . . . . . . . . . . . . . . . 171<br />

N9302782 . . . . . . . . . . . . . . . . . . . . . . . . . . 150<br />

N9302783 . . . . . . . . . . . . . . . . . . . . . . . . . . 150<br />

N9302784 . . . . . . . . . . . . . . . . . . . . . . . . . . . 89<br />

N9302785 . . . . . . . . . . . . . . . . . . . . . . . 90, 149<br />

N9302799 . . . . . . . . . . . . . . . . . . . . . . . 88, 161<br />

N9302800 . . . . . . . . . . . . . . . . . . . . . . . . . . 169<br />

N9302802 . . . . . . . . . . . . . . . . . . . . . . . . . . 169<br />

N9302803 . . . . . . . . . . . . . . . . . . . . . . . . . . 169<br />

N9302808 . . . . . . . . . . . . . . . . . . . . . . . . . . 169<br />

N9302809 . . . . . . . . . . . . . . . . . . . . . . . . . . 168<br />

N9302810 . . . . . . . . . . . . . . . . . . . . . . . . . . 168<br />

N9302811 . . . . . . . . . . . . . . . . . . . . . . . . . . 168<br />

N9302812 . . . . . . . . . . . . . . . . . . . . . . . . . . 168<br />

N9302813 . . . . . . . . . . . . . . . . . . . . . . . . . . 168<br />

N9302814 . . . . . . . . . . . . . . . . . . . . . . . . . . 168<br />

N9302815 . . . . . . . . . . . . . . . . . . . . . . . . . . 168<br />

N9302816 . . . . . . . . . . . . . . . . . . . . . . . . . . 168<br />

N9302817 . . . . . . . . . . . . . . . . . . . . . . . . . . 168<br />

N9302818 . . . . . . . . . . . . . . . . . . . . . . . . . . 168<br />

N9302819 . . . . . . . . . . . . . . . . . . . . . . . . . . 168<br />

N9302820 . . . . . . . . . . . . . . . . . . . . . . . . . . 168<br />

N9302821 . . . . . . . . . . . . . . . . . . . . . . . . . . 171<br />

N9302823 . . . . . . . . . . . . . . . . . . . . . . . . . . 170<br />

N9302825 . . . . . . . . . . . . . . . . . . . . . . . . . . 170<br />

N9302827 . . . . . . . . . . . . . . . . . . . . . . . . . . 170<br />

N9302832 . . . . . . . . . . . . . . . . . . . . . . 147, 172<br />

N9302833 . . . . . . . . . . . . . . . . . . . . . . . . . . 172<br />

N9302835 . . . . . . . . . . . . . . . . . . . . . . . . . . 172<br />

N9302836 . . . . . . . . . . . . . . . . . . . . . . . . . . 172<br />

N9302838 . . . . . . . . . . . . . . . . . . . . . . . . . . 172<br />

N9302839 . . . . . . . . . . . . . . . . . . . . . . . . . . 172<br />

N9302840 . . . . . . . . . . . . . . . . . . . . . . . . . . 172<br />

N9302841 . . . . . . . . . . . . . . . . . . . . . . . . . . 172<br />

N9302843 . . . . . . . . . . . . . . . . . . . . . . . . . . 172<br />

N9302846 . . . . . . . . . . . . . . . . . . . . . . . . . . 170<br />

Part No. Page Part No. Page Part No. Page<br />

See page 4 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

See page 2 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong>


Index Part Number N9302847 – N9303643<br />

Index<br />

Part Number<br />

424<br />

N9302847 . . . . . . . . . . . . . . . . . . . . . . . . . . 170<br />

N9302848 . . . . . . . . . . . . . . . . . . . . . . . . . . 170<br />

N9302849 . . . . . . . . . . . . . . . . . . . . . . . . . . 170<br />

N9302850 . . . . . . . . . . . . . . . . . . . . . . . . . . 170<br />

N9302851 . . . . . . . . . . . . . . . . . . . . . . . . . . 169<br />

N9302852 . . . . . . . . . . . . . . . . . . . . . . . . . . 169<br />

N9302853 . . . . . . . . . . . . . . . . . . . . . . . . . . 169<br />

N9302854 . . . . . . . . . . . . . . . . . . . . . . . . . . 169<br />

N9302855 . . . . . . . . . . . . . . . . . . . . . . . . . . 169<br />

N9302857 . . . . . . . . . . . . . . . . . . . . . . . . . . 169<br />

N9302858 . . . . . . . . . . . . . . . . . . . . . . . . . . 169<br />

N9302859 . . . . . . . . . . . . . . . . . . . . . . . . . . 169<br />

N9302860 . . . . . . . . . . . . . . . . . . . . . . . . . . 169<br />

N9302862 . . . . . . . . . . . . . . . . . . . . . . . . . . 169<br />

N9302866 . . . . . . . . . . . . . . . . . . . . . . . . . . 169<br />

N9302867 . . . . . . . . . . . . . . . . . . . . . . . . . . 169<br />

N9302868 . . . . . . . . . . . . . . . . . . . . . . . . . . 169<br />

N9302871 . . . . . . . . . . . . . . . . . . . . . . . . . . 171<br />

N9302872 . . . . . . . . . . . . . . . . . . . . . . . . . . 171<br />

N9302881 . . . . . . . . . . . . . . . . . . . . . . . . . . 170<br />

N9302882 . . . . . . . . . . . . . . . . . . . . . . . . . . 170<br />

N9302885 . . . . . . . . . . . . . . . . . . . . . . . . . . 168<br />

N9302886 . . . . . . . . . . . . . . . . . . . . . . . . . . 170<br />

N9302889 . . . . . . . . . . . . . . . . . . . . . . . . . . 169<br />

N9302890 . . . . . . . . . . . . . . . . . . . . . . . . . . 169<br />

N9302897 . . . . . . . . . . . . . . . . . . . . . . . . . . 168<br />

N9302899 . . . . . . . . . . . . . . . . . . . . . . . . . . 168<br />

N9302901 . . . . . . . . . . . . . . . . . . . . . . . . . . 168<br />

N9302903 . . . . . . . . . . . . . . . . . . . . . . . . . . 168<br />

N9302905 . . . . . . . . . . . . . . . . . . . . . . . . . . 168<br />

N9302908 . . . . . . . . . . . . . . . . . . . . . . . . . . 170<br />

N9302909 . . . . . . . . . . . . . . . . . . . . . . . . . . 171<br />

N9302910 . . . . . . . . . . . . . . . . . . . . . . . . . . 171<br />

N9302911 . . . . . . . . . . . . . . . . . . . . . . . . . . 171<br />

N9302912 . . . . . . . . . . . . . . . . . . . . . . . . . . 171<br />

N9302913 . . . . . . . . . . . . . . . . . . . . . . . . . . 170<br />

N9302914 . . . . . . . . . . . . . . . . . . . . . . . . . . 170<br />

N9302917 . . . . . . . . . . . . . . . . . . . . . . . . . . 172<br />

N9302918 . . . . . . . . . . . . . . . . . . . . . . . . . . 172<br />

N9302919 . . . . . . . . . . . . . . . . . . . . . . . . . . 172<br />

N9302920 . . . . . . . . . . . . . . . . . . . . . . . . . . 172<br />

N9302921 . . . . . . . . . . . . . . . . . . . . . . . . . . 172<br />

N9302922 . . . . . . . . . . . . . . . . . . . . . . . . . . 171<br />

N9302945 . . . . . . . . . . . . . . . . . . . . . . . . . . . 89<br />

N9302946 . . . . . . . . . . . . . . . . . . . . . . . . . . 236<br />

N9302950 . . . . . . . . . . . . . . . . . . . . . . . . . . 169<br />

N9302951 . . . . . . . . . . . . . . . . . . . . . . . . . . 169<br />

N9302952 . . . . . . . . . . . . . . . . . . . . . . . . . . 169<br />

N9302953 . . . . . . . . . . . . . . . . . . . . . . . . . . 169<br />

N9302954 . . . . . . . . . . . . . . . . . . . . . . . . . . 169<br />

N9302956 . . . . . . . . . . . . . . . . . . . . . . . . . . 169<br />

N9302957 . . . . . . . . . . . . . . . . . . . . . . . . . . 169<br />

N9302958 . . . . . . . . . . . . . . . . . . . . . . . . . . 169<br />

N9302960 . . . . . . . . . . . . . . . . . . . . . . . . . . 169<br />

N9302961 . . . . . . . . . . . . . . . . . . . . . . . . . . 169<br />

N9302962 . . . . . . . . . . . . . . . . . . . . . . . . . . 169<br />

N9302965 . . . . . . . . . . . . . . . . . . . . . . . . . . 169<br />

N9302966 . . . . . . . . . . . . . . . . . . . . . . . . . . 169<br />

N9302967 . . . . . . . . . . . . . . . . . . . . . . . . . . 169<br />

N9302972 . . . . . . . . . . . . . . . . . . 132, 137, 159<br />

N9302974 . . . . . . . . . . . . . . . . . . . . . . . . . . 167<br />

N9303314 . . . . . . . . . . . . . . . . . . . . . . . . . . 167<br />

N9303343 . . . . . . . . . . . . . . . . . . . . . . . . . . 159<br />

N9303344 . . . . . . . . . . . . . . . . . . . . . . 150, 159<br />

N9303345 . . . . . . . . . . . . . . . . . . . . . . 150, 159<br />

N9303396 . . . . . . . . . . . . . . . . . . . . . . . . . . 289<br />

N9303429 . . . . . . . . . . . . . . . . . . . . . . . . . . 167<br />

N9303430 . . . . . . . . . . . . . . . . . . . . . . . . . . 308<br />

N9303441 . . . . . . . . . . . . . . . . . . . . . . . . . . . 89<br />

N9303442 . . . . . . . . . . . . . . . . . . . . . . . . . . . 89<br />

N9303445 . . . . . . . . . . . . . . . . . . . . . 32, 35, 67<br />

N9303448 . . . . . . . . . . . . . . . . . . . . . . . . . . . 93<br />

N9303500 . . . . . . . . . . . . . . . . . . . . . . . . . . 308<br />

N9303501 . . . . . . . . . . . . . . . . . . . . . . . . . . 308<br />

N9303502 . . . . . . . . . . . . . . . . . . . . . . . . . . 308<br />

N9303503 . . . . . . . . . . . . . . . . . . . . . . . . . . 308<br />

N9303504 . . . . . . . . . . . . . . . . . . . . . . . . . . 308<br />

N9303505 . . . . . . . . . . . . . . . . . . . . . . . . . . 308<br />

N9303506 . . . . . . . . . . . . . . . . . . . . . . . . . . 308<br />

N9303507 . . . . . . . . . . . . . . . . . . . . . . . . . . 308<br />

N9303508 . . . . . . . . . . . . . . . . . . . . . . . . . . 308<br />

N9303509 . . . . . . . . . . . . . . . . . . . . . . . . . . 308<br />

N9303510 . . . . . . . . . . . . . . . . . . . . . . . . . . 308<br />

N9303511 . . . . . . . . . . . . . . . . . . . . . . . . . . 308<br />

N9303512 . . . . . . . . . . . . . . . . . . . . . . . . . . 308<br />

N9303513 . . . . . . . . . . . . . . . . . . . . . . . . . . 308<br />

N9303514 . . . . . . . . . . . . . . . . . . . . . . . . . . 308<br />

N9303515 . . . . . . . . . . . . . . . . . . . . . . . . . . 308<br />

N9303516 . . . . . . . . . . . . . . . . . . . . . . . . . . 308<br />

N9303517 . . . . . . . . . . . . . . . . . . . . . . . . . . 308<br />

N9303518 . . . . . . . . . . . . . . . . . . . . . . . . . . 308<br />

N9303519 . . . . . . . . . . . . . . . . . . . . . . . . . . 308<br />

N9303520 . . . . . . . . . . . . . . . . . . . . . . . . . . 308<br />

N9303521 . . . . . . . . . . . . . . . . . . . . . . . . . . 308<br />

N9303522 . . . . . . . . . . . . . . . . . . . . . . . . . . 308<br />

N9303523 . . . . . . . . . . . . . . . . . . . . . . . . . . 308<br />

N9303524 . . . . . . . . . . . . . . . . . . . . . . . . . . 308<br />

N9303525 . . . . . . . . . . . . . . . . . . . . . . . . . . 308<br />

N9303526 . . . . . . . . . . . . . . . . . . . . . . . . . . 308<br />

N9303527 . . . . . . . . . . . . . . . . . . . . . . . . . . 308<br />

N9303528 . . . . . . . . . . . . . . . . . . . . . . . . . . 308<br />

N9303529 . . . . . . . . . . . . . . . . . . . . . . . . . . 308<br />

N9303530 . . . . . . . . . . . . . . . . . . . . . . . . . . 308<br />

N9303531 . . . . . . . . . . . . . . . . . . . . . . . . . . 308<br />

N9303532 . . . . . . . . . . . . . . . . . . . . . . . . . . 311<br />

N9303533 . . . . . . . . . . . . . . . . . . . . . . . . . . 311<br />

N9303534 . . . . . . . . . . . . . . . . . . . . . . . . . . 311<br />

N9303535 . . . . . . . . . . . . . . . . . . . . . . . . . . 311<br />

N9303536 . . . . . . . . . . . . . . . . . . . . . . . . . . 311<br />

N9303537 . . . . . . . . . . . . . . . . . . . . . . . . . . 311<br />

N9303538 . . . . . . . . . . . . . . . . . . . . . . . . . . 311<br />

N9303539 . . . . . . . . . . . . . . . . . . . . . . . . . . 311<br />

N9303540 . . . . . . . . . . . . . . . . . . . . . . . . . . 311<br />

N9303541 . . . . . . . . . . . . . . . . . . . . . . . . . . 311<br />

N9303542 . . . . . . . . . . . . . . . . . . . . . . . . . . 311<br />

N9303543 . . . . . . . . . . . . . . . . . . . . . . . . . . 311<br />

N9303544 . . . . . . . . . . . . . . . . . . . . . . . . . . 311<br />

N9303545 . . . . . . . . . . . . . . . . . . . . . . . . . . 311<br />

N9303546 . . . . . . . . . . . . . . . . . . . . . . . . . . 311<br />

N9303547 . . . . . . . . . . . . . . . . . . . . . . . . . . 311<br />

N9303548 . . . . . . . . . . . . . . . . . . . . . . . . . . 311<br />

N9303549 . . . . . . . . . . . . . . . . . . . . . . . . . . 311<br />

N9303550 . . . . . . . . . . . . . . . . . . . . . . . . . . 311<br />

N9303551 . . . . . . . . . . . . . . . . . . . . . . . . . . 311<br />

N9303552 . . . . . . . . . . . . . . . . . . . . . . . . . . 311<br />

N9303553 . . . . . . . . . . . . . . . . . . . . . . . . . . 311<br />

N9303554 . . . . . . . . . . . . . . . . . . . . . . . . . . 311<br />

N9303556 . . . . . . . . . . . . . . . . . . . . . . . . . . 311<br />

N9303557 . . . . . . . . . . . . . . . . . . . . . . . . . . 311<br />

N9303558 . . . . . . . . . . . . . . . . . . . . . . . . . . 311<br />

N9303559 . . . . . . . . . . . . . . . . . . . . . . . . . . 311<br />

N9303560 . . . . . . . . . . . . . . . . . . . . . . . . . . 311<br />

N9303561 . . . . . . . . . . . . . . . . . . . . . . . . . . 311<br />

N9303562 . . . . . . . . . . . . . . . . . . . . . . . . . . 311<br />

N9303563 . . . . . . . . . . . . . . . . . . . . . . . . . . 311<br />

N9303564 . . . . . . . . . . . . . . . . . . . . . . . . . . 311<br />

N9303565 . . . . . . . . . . . . . . . . . . . . . . . . . . 311<br />

N9303566 . . . . . . . . . . . . . . . . . . . . . . . . . . 311<br />

N9303567 . . . . . . . . . . . . . . . . . . . . . . . . . . 311<br />

N9303568 . . . . . . . . . . . . . . . . . . . . . . . . . . 311<br />

N9303569 . . . . . . . . . . . . . . . . . . . . . . . . . . 312<br />

N9303570 . . . . . . . . . . . . . . . . . . . . . . . . . . 312<br />

N9303571 . . . . . . . . . . . . . . . . . . . . . . . . . . 312<br />

N9303572 . . . . . . . . . . . . . . . . . . . . . . . . . . 312<br />

N9303573 . . . . . . . . . . . . . . . . . . . . . . . . . . 312<br />

N9303574 . . . . . . . . . . . . . . . . . . . . . . . . . . 312<br />

N9303575 . . . . . . . . . . . . . . . . . . . . . . . . . . 312<br />

N9303576 . . . . . . . . . . . . . . . . . . . . . . . . . . 312<br />

N9303577 . . . . . . . . . . . . . . . . . . . . . . . . . . 312<br />

N9303578 . . . . . . . . . . . . . . . . . . . . . . . . . . 312<br />

N9303579 . . . . . . . . . . . . . . . . . . . . . . . . . . 312<br />

N9303580 . . . . . . . . . . . . . . . . . . . . . . . . . . 312<br />

N9303581 . . . . . . . . . . . . . . . . . . . . . . . . . . 312<br />

N9303582 . . . . . . . . . . . . . . . . . . . . . . . . . . 312<br />

N9303583 . . . . . . . . . . . . . . . . . . . . . . . . . . 312<br />

N9303584 . . . . . . . . . . . . . . . . . . . . . . . . . . 312<br />

N9303585 . . . . . . . . . . . . . . . . . . . . . . . . . . 312<br />

N9303586 . . . . . . . . . . . . . . . . . . . . . . . . . . 312<br />

N9303587 . . . . . . . . . . . . . . . . . . . . . . . . . . 312<br />

N9303588 . . . . . . . . . . . . . . . . . . . . . . . . . . 312<br />

N9303589 . . . . . . . . . . . . . . . . . . . . . . . . . . 312<br />

N9303590 . . . . . . . . . . . . . . . . . . . . . . . . . . 312<br />

N9303591 . . . . . . . . . . . . . . . . . . . . . . . . . . 312<br />

N9303592 . . . . . . . . . . . . . . . . . . . . . . . . . . 312<br />

N9303593 . . . . . . . . . . . . . . . . . . . . . . . . . . 312<br />

N9303594 . . . . . . . . . . . . . . . . . . . . . . . . . . 312<br />

N9303595 . . . . . . . . . . . . . . . . . . . . . . . . . . 312<br />

N9303596 . . . . . . . . . . . . . . . . . . . . . . . . . . 312<br />

N9303597 . . . . . . . . . . . . . . . . . . . . . . . . . . 312<br />

N9303598 . . . . . . . . . . . . . . . . . . . . . . . . . . 312<br />

N9303599 . . . . . . . . . . . . . . . . . . . . . . . . . . 312<br />

N9303600 . . . . . . . . . . . . . . . . . . . . . . . . . . 312<br />

N9303601 . . . . . . . . . . . . . . . . . . . . . . . . . . 312<br />

N9303602 . . . . . . . . . . . . . . . . . . . . . . . . . . 312<br />

N9303603 . . . . . . . . . . . . . . . . . . . . . . . . . . 312<br />

N9303604 . . . . . . . . . . . . . . . . . . . . . . . . . . 312<br />

N9303605 . . . . . . . . . . . . . . . . . . . . . . . . . . 312<br />

N9303606 . . . . . . . . . . . . . . . . . . . . . . . . . . 312<br />

N9303607 . . . . . . . . . . . . . . . . . . . . . . . . . . 312<br />

N9303608 . . . . . . . . . . . . . . . . . . . . . . . . . . 310<br />

N9303609 . . . . . . . . . . . . . . . . . . . . . . . . . . 310<br />

N9303610 . . . . . . . . . . . . . . . . . . . . . . . . . . 310<br />

N9303611 . . . . . . . . . . . . . . . . . . . . . . . . . . 310<br />

N9303612 . . . . . . . . . . . . . . . . . . . . . . . . . . 310<br />

N9303613 . . . . . . . . . . . . . . . . . . . . . . . . . . 310<br />

N9303614 . . . . . . . . . . . . . . . . . . . . . . . . . . 310<br />

N9303615 . . . . . . . . . . . . . . . . . . . . . . . . . . 310<br />

N9303616 . . . . . . . . . . . . . . . . . . . . . . . . . . 310<br />

N9303617 . . . . . . . . . . . . . . . . . . . . . . . . . . 310<br />

N9303618 . . . . . . . . . . . . . . . . . . . . . . . . . . 310<br />

N9303619 . . . . . . . . . . . . . . . . . . . . . . . . . . 310<br />

N9303620 . . . . . . . . . . . . . . . . . . . . . . . . . . 310<br />

N9303621 . . . . . . . . . . . . . . . . . . . . . . . . . . 310<br />

N9303622 . . . . . . . . . . . . . . . . . . . . . . . . . . 310<br />

N9303623 . . . . . . . . . . . . . . . . . . . . . . . . . . 310<br />

N9303624 . . . . . . . . . . . . . . . . . . . . . . . . . . 310<br />

N9303625 . . . . . . . . . . . . . . . . . . . . . . . . . . 310<br />

N9303626 . . . . . . . . . . . . . . . . . . . . . . . . . . 310<br />

N9303627 . . . . . . . . . . . . . . . . . . . . . . . . . . 310<br />

N9303628 . . . . . . . . . . . . . . . . . . . . . . . . . . 310<br />

N9303629 . . . . . . . . . . . . . . . . . . . . . . . . . . 310<br />

N9303630 . . . . . . . . . . . . . . . . . . . . . . . . . . 310<br />

N9303631 . . . . . . . . . . . . . . . . . . . . . . . . . . 310<br />

N9303632 . . . . . . . . . . . . . . . . . . . . . . . . . . 310<br />

N9303633 . . . . . . . . . . . . . . . . . . . . . . . . . . 310<br />

N9303634 . . . . . . . . . . . . . . . . . . . . . . . . . . 310<br />

N9303635 . . . . . . . . . . . . . . . . . . . . . . . . . . 310<br />

N9303636 . . . . . . . . . . . . . . . . . . . . . . . . . . 310<br />

N9303637 . . . . . . . . . . . . . . . . . . . . . . . . . . 310<br />

N9303638 . . . . . . . . . . . . . . . . . . . . . . . . . . 310<br />

N9303639 . . . . . . . . . . . . . . . . . . . . . . . . . . 310<br />

N9303640 . . . . . . . . . . . . . . . . . . . . . . . . . . 310<br />

N9303641 . . . . . . . . . . . . . . . . . . . . . . . . . . 310<br />

N9303641 . . . . . . . . . . . . . . . . . . . . . . . . . . 310<br />

N9303642 . . . . . . . . . . . . . . . . . . . . . . . . . . 310<br />

N9303643 . . . . . . . . . . . . . . . . . . . . . . . . . . 310<br />

Part No. Page Part No. Page Part No. Page


N9303644 – N9316016 Part Number Index<br />

Index<br />

Part Number<br />

425<br />

N9303644 . . . . . . . . . . . . . . . . . . . . . . . . . . 310<br />

N9303645 . . . . . . . . . . . . . . . . . . . . . . . . . . 310<br />

N9303646 . . . . . . . . . . . . . . . . . . . . . . . . . . 309<br />

N9303647 . . . . . . . . . . . . . . . . . . . . . . . . . . 309<br />

N9303648 . . . . . . . . . . . . . . . . . . . . . . . . . . 309<br />

N9303649 . . . . . . . . . . . . . . . . . . . . . . . . . . 309<br />

N9303650 . . . . . . . . . . . . . . . . . . . . . . . . . . 309<br />

N9303651 . . . . . . . . . . . . . . . . . . . . . . . . . . 309<br />

N9303652 . . . . . . . . . . . . . . . . . . . . . . . . . . 309<br />

N9303653 . . . . . . . . . . . . . . . . . . . . . . . . . . 309<br />

N9303654 . . . . . . . . . . . . . . . . . . . . . . . . . . 309<br />

N9303655 . . . . . . . . . . . . . . . . . . . . . . . . . . 309<br />

N9303656 . . . . . . . . . . . . . . . . . . . . . . . . . . 309<br />

N9303657 . . . . . . . . . . . . . . . . . . . . . . . . . . 309<br />

N9303658 . . . . . . . . . . . . . . . . . . . . . . . . . . 309<br />

N9303659 . . . . . . . . . . . . . . . . . . . . . . . . . . 309<br />

N9303660 . . . . . . . . . . . . . . . . . . . . . . . . . . 309<br />

N9303661 . . . . . . . . . . . . . . . . . . . . . . . . . . 309<br />

N9303662 . . . . . . . . . . . . . . . . . . . . . . . . . . 309<br />

N9303663 . . . . . . . . . . . . . . . . . . . . . . . . . . 309<br />

N9303664 . . . . . . . . . . . . . . . . . . . . . . . . . . 309<br />

N9303665 . . . . . . . . . . . . . . . . . . . . . . . . . . 309<br />

N9303666 . . . . . . . . . . . . . . . . . . . . . . . . . . 313<br />

N9303667 . . . . . . . . . . . . . . . . . . . . . . . . . . 313<br />

N9303668 . . . . . . . . . . . . . . . . . . . . . . . . . . 313<br />

N9303669 . . . . . . . . . . . . . . . . . . . . . . . . . . 313<br />

N9303670 . . . . . . . . . . . . . . . . . . . . . . . . . . 313<br />

N9303671 . . . . . . . . . . . . . . . . . . . . . . . . . . 313<br />

N9303672 . . . . . . . . . . . . . . . . . . . . . . . . . . 313<br />

N9303673 . . . . . . . . . . . . . . . . . . . . . . . . . . 313<br />

N9303674 . . . . . . . . . . . . . . . . . . . . . . . . . . 313<br />

N9303675 . . . . . . . . . . . . . . . . . . . . . . . . . . 313<br />

N9303676 . . . . . . . . . . . . . . . . . . . . . . . . . . 313<br />

N9303677 . . . . . . . . . . . . . . . . . . . . . . . . . . 313<br />

N9303678 . . . . . . . . . . . . . . . . . . . . . . . . . . 313<br />

N9303679 . . . . . . . . . . . . . . . . . . . . . . . . . . 313<br />

N9303680 . . . . . . . . . . . . . . . . . . . . . . . . . . 313<br />

N9303681 . . . . . . . . . . . . . . . . . . . . . . . . . . 313<br />

N9303682 . . . . . . . . . . . . . . . . . . . . . . . . . . 313<br />

N9303683 . . . . . . . . . . . . . . . . . . . . . . . . . . 313<br />

N9303684 . . . . . . . . . . . . . . . . . . . . . . . . . . 313<br />

N9303685 . . . . . . . . . . . . . . . . . . . . . . . . . . 313<br />

N9303686 . . . . . . . . . . . . . . . . . . . . . . . . . . 313<br />

N9303687 . . . . . . . . . . . . . . . . . . . . . . . . . . 313<br />

N9303688 . . . . . . . . . . . . . . . . . . . . . . . . . . 313<br />

N9303689 . . . . . . . . . . . . . . . . . . . . . . . . . . 313<br />

N9303690 . . . . . . . . . . . . . . . . . . . . . . . . . . 313<br />

N9303691 . . . . . . . . . . . . . . . . . . . . . . . . . . 313<br />

N9303692 . . . . . . . . . . . . . . . . . . . . . . . . . . 313<br />

N9303693 . . . . . . . . . . . . . . . . . . . . . . . . . . 313<br />

N9303694 . . . . . . . . . . . . . . . . . . . . . . . . . . 313<br />

N9303695 . . . . . . . . . . . . . . . . . . . . . . . . . . 313<br />

N9303696 . . . . . . . . . . . . . . . . . . . . . . . . . . 313<br />

N9303697 . . . . . . . . . . . . . . . . . . . . . . . . . . 313<br />

N9303698 . . . . . . . . . . . . . . . . . . . . . . . . . . 313<br />

N9303699 . . . . . . . . . . . . . . . . . . . . . . . . . . 313<br />

N9303700 . . . . . . . . . . . . . . . . . . . . . . . . . . 313<br />

N9303701 . . . . . . . . . . . . . . . . . . . . . . . . . . 313<br />

N9303702 . . . . . . . . . . . . . . . . . . . . . . . . . . 313<br />

N9303703 . . . . . . . . . . . . . . . . . . . . . . . . . . 313<br />

N9303704 . . . . . . . . . . . . . . . . . . . . . . . . . . 313<br />

N9303705 . . . . . . . . . . . . . . . . . . . . . . . . . . 313<br />

N9303706 . . . . . . . . . . . . . . . . . . . . . . . . . . 313<br />

N9303707 . . . . . . . . . . . . . . . . . . . . . . . . . . 313<br />

N9303708 . . . . . . . . . . . . . . . . . . . . . . . . . . 313<br />

N9303709 . . . . . . . . . . . . . . . . . . . . . . . . . . 313<br />

N9303710 . . . . . . . . . . . . . . . . . . . . . . . . . . 313<br />

N9303711 . . . . . . . . . . . . . . . . . . . . . . . . . . 313<br />

N9303712 . . . . . . . . . . . . . . . . . . . . . . . . . . 313<br />

N9303713 . . . . . . . . . . . . . . . . . . . . . . . . . . 313<br />

N9303714 . . . . . . . . . . . . . . . . . . . . . . . . . . 313<br />

N9303715 . . . . . . . . . . . . . . . . . . . . . . . . . . 313<br />

N9303716 . . . . . . . . . . . . . . . . . . . . . . . . . . 313<br />

N9303717 . . . . . . . . . . . . . . . . . . . . . . . . . . 313<br />

N9303718 . . . . . . . . . . . . . . . . . . . . . . . . . . 311<br />

N9303719 . . . . . . . . . . . . . . . . . . . . . . . . . . 311<br />

N9303720 . . . . . . . . . . . . . . . . . . . . . . . . . . 311<br />

N9303721 . . . . . . . . . . . . . . . . . . . . . . . . . . 311<br />

N9303722 . . . . . . . . . . . . . . . . . . . . . . . . . . 313<br />

N9303723 . . . . . . . . . . . . . . . . . . . . . . . . . . 313<br />

N9303759 . . . . . . . . . . . . . . . . . . . . . . . . . . . 68<br />

N9303761 . . . . . . . . . . . . . . . . . . . . . . . . . . . 68<br />

N9303763 . . . . . . . . . . . . . . . . . . . . . . . . . . . 68<br />

N9303766 . . . . . . . . . . . . . . . . . . . . . . . . . . . 68<br />

N9303771 . . . . . . . . . . . . . . . . . . . . . . . . . . . 68<br />

N9303775 . . . . . . . . . . . . . . . . . . . . . . . . . . . 68<br />

N9303779 . . . . . . . . . . . . . . . . . . . . . . . . . . . 69<br />

N9303783 . . . . . . . . . . . . . . . . . . . . . . . . . . . 68<br />

N9303784 . . . . . . . . . . . . . . . . . . . . . . . . . . . 69<br />

N9303785 . . . . . . . . . . . . . . . . . . . . . . . . . . . 69<br />

N9303788 . . . . . . . . . . . . . . . . . . . . . . . . . . . 69<br />

N9303789 . . . . . . . . . . . . . . . . . . . . . . . . . . . 69<br />

N9303799 . . . . . . . . . . . . . . . . . . . . . . . . . . . 69<br />

N9303801 . . . . . . . . . . . . . . . . . . . . . . . . . . . 69<br />

N9303806 . . . . . . . . . . . . . . . . . . . . . . . . . . . 69<br />

N9303810 . . . . . . . . . . . . . . . . . . . . . . . . . . . 69<br />

N9303812 . . . . . . . . . . . . . . . . . . . . . . . . . . . 69<br />

N9304012 . . . . . . . . . . . . . . . . . . . . . . . . . . 130<br />

N9304013 . . . . . . . . . . . . . . . . . . . . . . . . . . 130<br />

N9304014 . . . . . . . . . . . . . . . . . . . . . . . . . . 130<br />

N9304016 . . . . . . . . . . . . . . . . . . . . . . . . . . 130<br />

N9304017 . . . . . . . . . . . . . . . . . . . . . . . . . . 130<br />

N9304018 . . . . . . . . . . . . . . . . . . . . . . . . . . 130<br />

N9304019 . . . . . . . . . . . . . . . . . . . . . . . . . . 130<br />

N9304020 . . . . . . . . . . . . . . . . . . . . . . . . . . 130<br />

N9304021 . . . . . . . . . . . . . . . . . . . . . . . . . . 130<br />

N9304022 . . . . . . . . . . . . . . . . . . . . . . . . . . 130<br />

N9304023 . . . . . . . . . . . . . . . . . . . . . . . . . . 130<br />

N9304046 . . . . . . . . . . . . . . . . . . . . . . . . . . 130<br />

N9304047 . . . . . . . . . . . . . . . . . . . . . . . . . . 130<br />

N9304048 . . . . . . . . . . . . . . . . . . . . . . . . . . 130<br />

N9305012 . . . . . . . . . . . . . . . . . . . . . . . . . . 130<br />

N9305013 . . . . . . . . . . . . . . . . . . . . . . . . . . 130<br />

N9305014 . . . . . . . . . . . . . . . . . . . . . . . . . . 130<br />

N9305016 . . . . . . . . . . . . . . . . . . . . . . . . . . 130<br />

N9305017 . . . . . . . . . . . . . . . . . . . . . . . . . . 130<br />

N9305018 . . . . . . . . . . . . . . . . . . . . . . . . . . 130<br />

N9305019 . . . . . . . . . . . . . . . . . . . . . . . . . . 130<br />

N9305022 . . . . . . . . . . . . . . . . . . . . . . . . . . 130<br />

N9305047 . . . . . . . . . . . . . . . . . . . . . . . . . . 130<br />

N9305048 . . . . . . . . . . . . . . . . . . . . . . . . . . 130<br />

N9306000 . . . . . . . . . . . . . . . . . . . . . . . . . . . 94<br />

N9306001 . . . . . . . . . . . . . . . . . . . . . . . . . . . 94<br />

N9306002 . . . . . . . . . . . . . . . . . . . . . . . . . . 164<br />

N9306003 . . . . . . . . . . . . . . . . . . . . . . . . . . 164<br />

N9306004 . . . . . . . . . . . . . . . . . . . . . . . . . . 164<br />

N9306005 . . . . . . . . . . . . . . . . . . . . . . . . . . 164<br />

N9306006 . . . . . . . . . . . . . . . . . . . . . . . . . . 164<br />

N9306014 . . . . . . . . . . . . . . . . . . . . . . . . . . 164<br />

N9306015 . . . . . . . . . . . . . . . . . . . . . . . 89, 271<br />

N9306016 . . . . . . . . . . . . . . . . . . . . . . . . . . . 23<br />

N9306017 . . . . . . . . . . . . . . . . . . . . . . . . . . 324<br />

N9306019 . . . . . . . . . . . . . . . . . . . . . . . . . . 324<br />

N9306020 . . . . . . . . . . . . . . . . . . . . . . . . . . 324<br />

N9306021 . . . . . . . . . . . . . . . . . . . . . . . . . . 324<br />

N9306022 . . . . . . . . . . . . . . . . . . . . . . . . . . 326<br />

N9306023 . . . . . . . . . . . . . . . . . . . . . . . . . . 326<br />

N9306024 . . . . . . . . . . . . . . . . . . . . . . . . . . 326<br />

N9306025 . . . . . . . . . . . . . . . . . . . . . . . . . . 326<br />

N9306026 . . . . . . . . . . . . . . . . . . . . . . . . . . 326<br />

N9306027 . . . . . . . . . . . . . . . . . . . . . . . . . . 326<br />

N9306028 . . . . . . . . . . . . . . . . . . . . . . . . . . 326<br />

N9306029 . . . . . . . . . . . . . . . . . . . . . . . . . . 326<br />

N9306030 . . . . . . . . . . . . . . . . . . . . . . . . . . 326<br />

N9306031 . . . . . . . . . . . . . . . . . . . . . . . . . . 326<br />

N9306032 . . . . . . . . . . . . . . . . . . . . . . . . . . 326<br />

N9306033 . . . . . . . . . . . . . . . . . . . . . . . . . . 326<br />

N9306034 . . . . . . . . . . . . . . . . . . . . . . . . . . 326<br />

N9306035 . . . . . . . . . . . . . . . . . . . . . . . . . . 326<br />

N9306036 . . . . . . . . . . . . . . . . . . . . . . . . . . 326<br />

N9306037 . . . . . . . . . . . . . . . . . . . . . . . . . . 326<br />

N9306038 . . . . . . . . . . . . . . . . . . . . . . . . . . 326<br />

N9306039 . . . . . . . . . . . . . . . . . . . . . . . . . . 326<br />

N9306040 . . . . . . . . . . . . . . . . . . . . . . . . . . 326<br />

N9306041 . . . . . . . . . . . . . . . . . . . . . . . . . . 326<br />

N9306042 . . . . . . . . . . . . . . . . . . . . . . . . . . 326<br />

N9306044 . . . . . . . . . . . . . . . . . . . . . . . . . . 325<br />

N9306045 . . . . . . . . . . . . . . . . . . . . . . . . . . 325<br />

N9306046 . . . . . . . . . . . . . . . . . . . . . . . . . . 325<br />

N9306047 . . . . . . . . . . . . . . . . . . . . . . . . . . 325<br />

N9306048 . . . . . . . . . . . . . . . . . . . . . . . . . . 164<br />

N9306050 . . . . . . . . . . . . . . . . . . . . . . . . . . 164<br />

N9306051 . . . . . . . . . . . . . . . . . . . . . . . . . . 164<br />

N9306052 . . . . . . . . . . . . . . . . . . . . . . . . . . 271<br />

N9306053 . . . . . . . . . . . . . . . . . . . . . . . . . . 271<br />

N9306057 . . . . . . . . . . . . . . . . . . . . . . . . . . 271<br />

N9306058 . . . . . . . . . . . . . . . . . . . . . . . . . . 165<br />

N9306059 . . . . . . . . . . . . . . . . . . . . . . . . . . 165<br />

N9306060 . . . . . . . . . . . . . . . . . . . . . . . . . . 165<br />

N9306061 . . . . . . . . . . . . . . . . . . . . . . . . . . 165<br />

N9306064 . . . . . . . . . . . . . . . . . . . . . . . . . . 165<br />

N9306065 . . . . . . . . . . . . . . . . . . . . . . . . . . 165<br />

N9306066 . . . . . . . . . . . . . . . . . . . . . . . . . . 165<br />

N9306080 . . . . . . . . . . . . . . . . . . . . . . . . . . 271<br />

N9306090 . . . . . . . . . . . . . . . . . . . . . . . . . . . 94<br />

N9306091 . . . . . . . . . . . . . . . . . . . . . . . . . . . 94<br />

N9306092 . . . . . . . . . . . . . . . . . . . . . . . . . . . 94<br />

N9306093 . . . . . . . . . . . . . . . . . . . . . . . . . . . 94<br />

N9306094 . . . . . . . . . . . . . . . . . . . . . . . . . . . 94<br />

N9306095 . . . . . . . . . . . . . . . . . . . . . . . . . . . 94<br />

N9306096 . . . . . . . . . . . . . . . . . . . . . . . . . . . 94<br />

N9307000 . . . . . . . . . . . . . . . . . . . . . . . . . . 181<br />

N9307001 . . . . . . . . . . . . . . . . . . . . . . . . . . 181<br />

N9307002 . . . . . . . . . . . . . . . . . . . . . . . . . . 181<br />

N9307003 . . . . . . . . . . . . . . . . . . . . . . . . . . 181<br />

N9307004 . . . . . . . . . . . . . . . . . . . . . . . . . . 181<br />

N9307005 . . . . . . . . . . . . . . . . . . . . . . . . . . 181<br />

N9307006 . . . . . . . . . . . . . . . . . . . . . . . . . . 181<br />

N9307007 . . . . . . . . . . . . . . . . . . . . . . . . . . 181<br />

N9307008 . . . . . . . . . . . . . . . . . . . . . . . . . . 181<br />

N9307009 . . . . . . . . . . . . . . . . . . . . . . . . . . 181<br />

N9307010 . . . . . . . . . . . . . . . . . . . . . . . . . . 181<br />

N9307011 . . . . . . . . . . . . . . . . . . . . . . . . . . 181<br />

N9307012 . . . . . . . . . . . . . . . . . . . . . . . . . . 181<br />

N9307013 . . . . . . . . . . . . . . . . . . . . . . . . . . 181<br />

N9307027 . . . . . . . . . . . . . . . . . . . . . . . . . . 271<br />

N9307029 . . . . . . . . . . . . . . . . . . . . . . . . . . 167<br />

N9307037 . . . . . . . . . . . . . . . . . . . . . . . . . . 181<br />

N9307038 . . . . . . . . . . . . . . . . . . . . . . . . . . 181<br />

N9316000 . . . . . . . . . . . . . . . . . . . . . . . . . . 180<br />

N9316001 . . . . . . . . . . . . . . . . . . . . . . . . . . 121<br />

N9316002 . . . . . . . . . . . . . . . . . . . . . . . . . . 121<br />

N9316003 . . . . . . . . . . . . . . . . . . . . . . . . . . 121<br />

N9316004 . . . . . . . . . . . . . . . . . . . . . . . . . . 121<br />

N9316005 . . . . . . . . . . . . . . . . . . . . . . . . . . 121<br />

N9316006 . . . . . . . . . . . . . . . . . . . . . . . . . . 121<br />

N9316007 . . . . . . . . . . . . . . . . . . . . . . . . . . 121<br />

N9316008 . . . . . . . . . . . . . . . . . . . . . . . . . . 121<br />

N9316009 . . . . . . . . . . . . . . . . . . . . . . . . . . 121<br />

N9316010 . . . . . . . . . . . . . . . . . . . . . . . . . . 121<br />

N9316011 . . . . . . . . . . . . . . . . . . . . . . . . . . 121<br />

N9316012 . . . . . . . . . . . . . . . . . . . . . . . . . . 121<br />

N9316013 . . . . . . . . . . . . . . . . . . . . . . . . . . 121<br />

N9316014 . . . . . . . . . . . . . . . . . . . . . . . . . . 121<br />

N9316015 . . . . . . . . . . . . . . . . . . . . . . 121, 127<br />

N9316016 . . . . . . . . . . . . . . . . . . . . . . . . . . 121<br />

Part No. Page Part No. Page Part No. Page<br />

See page 4 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

See page 2 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong>


Index Part Number N9316017 – N9316257<br />

Index<br />

Part Number<br />

426<br />

N9316017 . . . . . . . . . . . . . . . . . . . . . . . . . . 121<br />

N9316018 . . . . . . . . . . . . . . . . . . . . . . . . . . 121<br />

N9316019 . . . . . . . . . . . . . . . . . . . . . . . . . . 121<br />

N9316020 . . . . . . . . . . . . . . . . . . . . . . . . . . 121<br />

N9316021 . . . . . . . . . . . . . . . . . . . . . . . . . . 121<br />

N9316022 . . . . . . . . . . . . . . . . . . . . . . . . . . 121<br />

N9316023 . . . . . . . . . . . . . . . . . . . . . . . 97, 121<br />

N9316024 . . . . . . . . . . . . . . . . . . . . 97-98, 121<br />

N9316025 . . . . . . . . . . . . . . . . . . . . . . . . . . 121<br />

N9316026 . . . . . . . . . . . . . . . . . . . . . . . . . . 121<br />

N9316027 . . . . . . . . . . . . . . . . . . . . . . . . . . 121<br />

N9316028 . . . . . . . . . . . . . . . . . . . . . . . . . . 121<br />

N9316029 . . . . . . . . . . . . . . . . . . . . . . . . . . 121<br />

N9316030 . . . . . . . . . . . . . . . . . . . . . . . . . . 121<br />

N9316031 . . . . . . . . . . . . . . . . . . . . . . . . . . 121<br />

N9316032 . . . . . . . . . . . . . . . . . . . . . . . . . . 121<br />

N9316033 . . . . . . . . . . . . . . . . . . . . . . . . . . 121<br />

N9316034 . . . . . . . . . . . . . . . . . . . . . . . . . . 121<br />

N9316035 . . . . . . . . . . . . . . . . . . . . . . . . . . 121<br />

N9316036 . . . . . . . . . . . . . . . . . . . . . . . . . . 121<br />

N9316037 . . . . . . . . . . . . . . . . . . . . . . . . . . 121<br />

N9316038 . . . . . . . . . . . . . . . . . . . . . . . . . . 121<br />

N9316039 . . . . . . . . . . . . . . . . . . . . . . . . . . 121<br />

N9316040 . . . . . . . . . . . . . . . . . . . . . . . . . . 121<br />

N9316041 . . . . . . . . . . . . . . . . . . . . . . . . . . 121<br />

N9316042 . . . . . . . . . . . . . . . . . . . . . . . . . . 121<br />

N9316043 . . . . . . . . . . . . . . . . . . . . . . . . . . 121<br />

N9316044 . . . . . . . . . . . . . . . . . . . . . . . . . . 121<br />

N9316045 . . . . . . . . . . . . . . . . . . . . . . . . . . 121<br />

N9316046 . . . . . . . . . . . . . . . . . . . . 97-98, 121<br />

N9316047 . . . . . . . . . . . . . . . . . . . . . . . . . . 121<br />

N9316048 . . . . . . . . . . . . . . . . . . . . . . . . . . 121<br />

N9316049 . . . . . . . . . . . . . . . . . . . . . . . . . . 121<br />

N9316050 . . . . . . . . . . . . . . . . . . . . 97-98, 121<br />

N9316051 . . . . . . . . . . . . . . . . . . . . . . . . . . 121<br />

N9316052 . . . . . . . . . . . . . . . . . . . . . . . . . . 121<br />

N9316053 . . . . . . . . . . . . . . . . . . . . . . . . . . 121<br />

N9316054 . . . . . . . . . . . . . . . . . . . . . . . . . . 121<br />

N9316056 . . . . . . . . . . . . . . . . . . . . . . . . . . 121<br />

N9316057 . . . . . . . . . . . . . . . . . . . . . . . . . . 121<br />

N9316058 . . . . . . . . . . . . . . . . . . . . . . . . . . 121<br />

N9316061 . . . . . . . . . . . . . . . . . . . . . . . . . . 121<br />

N9316062 . . . . . . . . . . . . . . . . . . . . . . . . . . 121<br />

N9316063 . . . . . . . . . . . . . . . . . . . . . . . . . . 121<br />

N9316064 . . . . . . . . . . . . . . . . . . . . . . . . . . 121<br />

N9316065 . . . . . . . . . . . . . . . . . . . . . . . . . . 127<br />

N9316066 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />

N9316067 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />

N9316068 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />

N9316069 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />

N9316071 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />

N9316072 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />

N9316073 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />

N9316074 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />

N9316075 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />

N9316076 . . . . . . . . . . . . . . . . . . . . 97-98, 122<br />

N9316077 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />

N9316078 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />

N9316079 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />

N9316080 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />

N9316081 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />

N9316082 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />

N9316083 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />

N9316084 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />

N9316085 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />

N9316086 . . . . . . . . . . . . . . . . . . . . 97-98, 122<br />

N9316087 . . . . . . . . . . . . . . . . . . . . 97-98, 122<br />

N9316088 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />

N9316089 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />

N9316090 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />

N9316091 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />

N9316092 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />

N9316093 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />

N9316094 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />

N9316095 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />

N9316096 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />

N9316097 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />

N9316098 . . . . . . . . . . . . . . . . . . . . 97-98, 122<br />

N9316099 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />

N9316100 . . . . . . . . . . . . . . . . . . . . 97-98, 122<br />

N9316101 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />

N9316102 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />

N9316103 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />

N9316104 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />

N9316105 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />

N9316108 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />

N9316109 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />

N9316110 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />

N9316111 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />

N9316112 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />

N9316113 . . . . . . . . . . . . . . . . . . . . . . . . . . 123<br />

N9316114 . . . . . . . . . . . . . . . . . . . . . . . . . . 123<br />

N9316115 . . . . . . . . . . . . . . . . . . . . . . . . . . 123<br />

N9316116 . . . . . . . . . . . . . . . . . . . . . . . . . . 123<br />

N9316117 . . . . . . . . . . . . . . . . . . . . . . . . . . 123<br />

N9316118 . . . . . . . . . . . . . . . . . . . . . . . . . . 123<br />

N9316119 . . . . . . . . . . . . . . . . . . . . . . . . . . 123<br />

N9316120 . . . . . . . . . . . . . . . . . . . . . . . . . . 123<br />

N9316121 . . . . . . . . . . . . . . . . . . . . . . . . . . 123<br />

N9316122 . . . . . . . . . . . . . . . . . . . . . . . . . . 123<br />

N9316123 . . . . . . . . . . . . . . . . . . . . . . . . . . 123<br />

N9316124 . . . . . . . . . . . . . . . . . . . . . . . . . . 123<br />

N9316125 . . . . . . . . . . . . . . . . . . . . . . . . . . 123<br />

N9316126 . . . . . . . . . . . . . . . . . . . . . . . . . . 123<br />

N9316127 . . . . . . . . . . . . . . . . . . . . . . . . . . 123<br />

N9316128 . . . . . . . . . . . . . . . . . . . . . . . . . . 123<br />

N9316129 . . . . . . . . . . . . . . . . . . . . . . . 97, 123<br />

N9316130 . . . . . . . . . . . . . . . . . . . . . . . . . . 123<br />

N9316131 . . . . . . . . . . . . . . . . . . . . . . . . . . 123<br />

N9316132 . . . . . . . . . . . . . . . . . . . . . . . . . . 123<br />

N9316133 . . . . . . . . . . . . . . . . . . . . . . . . . . 123<br />

N9316134 . . . . . . . . . . . . . . . . . . . . . . . . . . 123<br />

N9316135 . . . . . . . . . . . . . . . . . . . . . . . . . . 123<br />

N9316136 . . . . . . . . . . . . . . . . . . . . . . . 97, 123<br />

N9316137 . . . . . . . . . . . . . . . . . . . . . . . . . . 123<br />

N9316138 . . . . . . . . . . . . . . . . . . . . . . . . . . 123<br />

N9316139 . . . . . . . . . . . . . . . . . . . . . . . . . . 123<br />

N9316140 . . . . . . . . . . . . . . . . . . . . . . . . . . 123<br />

N9316141 . . . . . . . . . . . . . . . . . . . . . . . . . . 123<br />

N9316142 . . . . . . . . . . . . . . . . . . . . . . . . . . 123<br />

N9316143 . . . . . . . . . . . . . . . . . . . . . . . . . . 123<br />

N9316144 . . . . . . . . . . . . . . . . . . . . . . . . . . 123<br />

N9316145 . . . . . . . . . . . . . . . . . . . . . . . . . . 123<br />

N9316146 . . . . . . . . . . . . . . . . . . . . . . . . . . 123<br />

N9316147 . . . . . . . . . . . . . . . . . . . . . . . . . . 123<br />

N9316148 . . . . . . . . . . . . . . . . . . . . . . . . . . 123<br />

N9316149 . . . . . . . . . . . . . . . . . . . . . . . . . . 123<br />

N9316150 . . . . . . . . . . . . . . . . . . . . . . . . . . 123<br />

N9316151 . . . . . . . . . . . . . . . . . . . . . . . . . . 123<br />

N9316152 . . . . . . . . . . . . . . . . . . . . . . . 97, 123<br />

N9316153 . . . . . . . . . . . . . . . . . . . . . . . 98, 123<br />

N9316172 . . . . . . . . . . . . . . . . . . . . . . . . . . 124<br />

N9316173 . . . . . . . . . . . . . . . . . . . . . . . . . . 124<br />

N9316174 . . . . . . . . . . . . . . . . . . . . . . . . . . 124<br />

N9316175 . . . . . . . . . . . . . . . . . . . . . . . . . . 124<br />

N9316176 . . . . . . . . . . . . . . . . . . . . . . . . . . 124<br />

N9316177 . . . . . . . . . . . . . . . . . . . . . . . . . . 124<br />

N9316178 . . . . . . . . . . . . . . . . . . . . . . . . . . 124<br />

N9316179 . . . . . . . . . . . . . . . . . . . . . . . . . . 124<br />

N9316180 . . . . . . . . . . . . . . . . . . . . . . . . . . 124<br />

N9316181 . . . . . . . . . . . . . . . . . . . . . . . . . . 124<br />

N9316182 . . . . . . . . . . . . . . . . . . . . . . . . . . 124<br />

N9316183 . . . . . . . . . . . . . . . . . . . . . . . . . . 124<br />

N9316184 . . . . . . . . . . . . . . . . . . . . . . . . . . 124<br />

N9316185 . . . . . . . . . . . . . . . . . . . . . . . . . . 124<br />

N9316186 . . . . . . . . . . . . . . . . . . . . . . . . . . 124<br />

N9316187 . . . . . . . . . . . . . . . . . . . . . . . . . . 124<br />

N9316188 . . . . . . . . . . . . . . . . . . . . . . . . . . 124<br />

N9316189 . . . . . . . . . . . . . . . . . . . . . . . . . . 124<br />

N9316190 . . . . . . . . . . . . . . . . . . . . . . . 97, 124<br />

N9316191 . . . . . . . . . . . . . . . . . . . . . . . 97, 124<br />

N9316192 . . . . . . . . . . . . . . . . . . . . . . . . . . 124<br />

N9316193 . . . . . . . . . . . . . . . . . . . . . . . . . . 124<br />

N9316194 . . . . . . . . . . . . . . . . . . . . . . . . . . 124<br />

N9316195 . . . . . . . . . . . . . . . . . . . . . . . . . . 124<br />

N9316196 . . . . . . . . . . . . . . . . . . . . . . . . . . 124<br />

N9316197 . . . . . . . . . . . . . . . . . . . . 97-98, 124<br />

N9316198 . . . . . . . . . . . . . . . . . . . . . . . . . . 124<br />

N9316199 . . . . . . . . . . . . . . . . . . . . . . . . . . 124<br />

N9316200 . . . . . . . . . . . . . . . . . . . . . . . . . . 125<br />

N9316201 . . . . . . . . . . . . . . . . . . . . . . . 97, 125<br />

N9316202 . . . . . . . . . . . . . . . . . . . . . . . . . . 125<br />

N9316203 . . . . . . . . . . . . . . . . . . . . . . . . . . 125<br />

N9316204 . . . . . . . . . . . . . . . . . . . . . . . . . . 125<br />

N9316205 . . . . . . . . . . . . . . . . . . . . . . . . . . 125<br />

N9316206 . . . . . . . . . . . . . . . . . . . . . . . 97, 125<br />

N9316207 . . . . . . . . . . . . . . . . . . . . 97-98, 125<br />

N9316208 . . . . . . . . . . . . . . . . . . . . 97-98, 125<br />

N9316209 . . . . . . . . . . . . . . . . . . . . . . . . . . 125<br />

N9316210 . . . . . . . . . . . . . . . . . . . . . . . . . . 125<br />

N9316211 . . . . . . . . . . . . . . . . . . . . . . . . . . 125<br />

N9316212 . . . . . . . . . . . . . . . . . . . . . . . . . . 125<br />

N9316213 . . . . . . . . . . . . . . . . . . . . . . . . . . 125<br />

N9316214 . . . . . . . . . . . . . . . . . . . . . . . . . . 125<br />

N9316215 . . . . . . . . . . . . . . . . . . . . . . . . . . 125<br />

N9316216 . . . . . . . . . . . . . . . . . . . . . . . . . . 125<br />

N9316217 . . . . . . . . . . . . . . . . . . . . . . . . . . 125<br />

N9316218 . . . . . . . . . . . . . . . . . . . . . . . . . . 125<br />

N9316219 . . . . . . . . . . . . . . . . . . . . . . . . . . 125<br />

N9316220 . . . . . . . . . . . . . . . . . . . . . . . . . . 125<br />

N9316221 . . . . . . . . . . . . . . . . . . . . . . . . . . 125<br />

N9316222 . . . . . . . . . . . . . . . . . . . . . . . . . . 125<br />

N9316223 . . . . . . . . . . . . . . . . . . . . . . . . . . 125<br />

N9316224 . . . . . . . . . . . . . . . . . . . . . . . . . . 125<br />

N9316225 . . . . . . . . . . . . . . . . . . . . . . . . . . 125<br />

N9316226 . . . . . . . . . . . . . . . . . . . . . . . . . . 125<br />

N9316227 . . . . . . . . . . . . . . . . . . . . . . . . . . 125<br />

N9316228 . . . . . . . . . . . . . . . . . . . . . . . . . . 125<br />

N9316229 . . . . . . . . . . . . . . . . . . . . . . . . . . 125<br />

N9316230 . . . . . . . . . . . . . . . . . . . . . . . . . . 125<br />

N9316231 . . . . . . . . . . . . . . . . . . . . . . . . . . 125<br />

N9316232 . . . . . . . . . . . . . . . . . . . . . . . . . . 125<br />

N9316234 . . . . . . . . . . . . . . . . . . . . . . . 97, 125<br />

N9316235 . . . . . . . . . . . . . . . . . . . . . . . . . . 125<br />

N9316236 . . . . . . . . . . . . . . . . . . . . . . . . . . 125<br />

N9316237 . . . . . . . . . . . . . . . . . . . . . . . . . . 125<br />

N9316238 . . . . . . . . . . . . . . . . . . . . . . . . . . 125<br />

N9316239 . . . . . . . . . . . . . . . . . . . . . . . . . . 125<br />

N9316240 . . . . . . . . . . . . . . . . . . . . . . . . . . 125<br />

N9316241 . . . . . . . . . . . . . . . . . . . . . . . . . . 125<br />

N9316242 . . . . . . . . . . . . . . . . . . . . . . . . . . 125<br />

N9316243 . . . . . . . . . . . . . . . . . . . . . . . 97, 125<br />

N9316244 . . . . . . . . . . . . . . . . . . . . . . . . . . 125<br />

N9316245 . . . . . . . . . . . . . . . . . . . . . . . . . . 125<br />

N9316246 . . . . . . . . . . . . . . . . . . . . . . . . . . 125<br />

N9316247 . . . . . . . . . . . . . . . . . . . . . . . . . . 125<br />

N9316248 . . . . . . . . . . . . . . . . . . . . . . . . . . 125<br />

N9316249 . . . . . . . . . . . . . . . . . . . . . . . . . . 125<br />

N9316250 . . . . . . . . . . . . . . . . . . . . . . . . . . 125<br />

N9316251 . . . . . . . . . . . . . . . . . . . . . . . . . . 125<br />

N9316252 . . . . . . . . . . . . . . . . . . . . . . . . . . 125<br />

N9316253 . . . . . . . . . . . . . . . . . . . . . . . . . . 125<br />

N9316254 . . . . . . . . . . . . . . . . . . . . . . . . . . 125<br />

N9316255 . . . . . . . . . . . . . . . . . . . . 97-98, 125<br />

N9316256 . . . . . . . . . . . . . . . . . . . . . . . . . . 125<br />

N9316257 . . . . . . . . . . . . . . . . . . . . . . . . . . 125<br />

Part No. Page Part No. Page Part No. Page


N9316258 – N9316627 Part Number Index<br />

Index<br />

Part Number<br />

427<br />

N9316258 . . . . . . . . . . . . . . . . . . . . . . . . . . 125<br />

N9316259 . . . . . . . . . . . . . . . . . . . . . . . . . . 125<br />

N9316260 . . . . . . . . . . . . . . . . . . . . . . . . . . 125<br />

N9316261 . . . . . . . . . . . . . . . . . . . . . . . . . . 127<br />

N9316262 . . . . . . . . . . . . . . . . . . . . . . . . . . 127<br />

N9316263 . . . . . . . . . . . . . . . . . . . . . . . . . . 123<br />

N9316264 . . . . . . . . . . . . . . . . . . . . . . . . . . 123<br />

N9316265 . . . . . . . . . . . . . . . . . . . . . . . . . . 123<br />

N9316266 . . . . . . . . . . . . . . . . . . . . . . . . . . 123<br />

N9316267 . . . . . . . . . . . . . . . . . . . . . . . . . . 123<br />

N9316268 . . . . . . . . . . . . . . . . . . . . . . . . . . 121<br />

N9316269 . . . . . . . . . . . . . . . . . . . . . . . . . . 121<br />

N9316270 . . . . . . . . . . . . . . . . . . . . . . . . . . 121<br />

N9316271 . . . . . . . . . . . . . . . . . . . . . . . . . . 121<br />

N9316272 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />

N9316273 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />

N9316274 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />

N9316275 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />

N9316276 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />

N9316277 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />

N9316278 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />

N9316279 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />

N9316280 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />

N9316281 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />

N9316282 . . . . . . . . . . . . . . . . . . . . . . . 97, 122<br />

N9316283 . . . . . . . . . . . . . . . . . . . . 97-98, 122<br />

N9316284 . . . . . . . . . . . . . . . . . . . . . . . 98, 122<br />

N9316285 . . . . . . . . . . . . . . . . . . . . . . . 97, 122<br />

N9316286 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />

N9316287 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />

N9316288 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />

N9316289 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />

N9316290 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />

N9316291 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />

N9316292 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />

N9316293 . . . . . . . . . . . . . . . . . . . . 97-98, 122<br />

N9316294 . . . . . . . . . . . . . . . . . . . . . . . 98, 122<br />

N9316295 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />

N9316296 . . . . . . . . . . . . . . . . . . . . . . . 97, 122<br />

N9316297 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />

N9316298 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />

N9316299 . . . . . . . . . . . . . . . . . . . . . . . 97, 122<br />

N9316300 . . . . . . . . . . . . . . . . . . . . 97-98, 122<br />

N9316301 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />

N9316302 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />

N9316303 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />

N9316304 . . . . . . . . . . . . . . . . . . . . . . . . . . 129<br />

N9316305 . . . . . . . . . . . . . . . . . . . . . . . . . . 129<br />

N9316319 . . . . . . . . . . . . . . . . . . . . . . . . . . 125<br />

N9316345 . . . . . . . . . . . . . . . . . . . . . . . . . . 127<br />

N9316346 . . . . . . . . . . . . . . . . . . . . . . . . . . 127<br />

N9316347 . . . . . . . . . . . . . . . . . . . . . . . . . . 127<br />

N9316348 . . . . . . . . . . . . . . . . . . . . . . . . . . 127<br />

N9316349 . . . . . . . . . . . . . . . . . . . . . . . . . . 127<br />

N9316350 . . . . . . . . . . . . . . . . . . . . . . . . . . 127<br />

N9316351 . . . . . . . . . . . . . . . . . . . . . . . . . . 127<br />

N9316352 . . . . . . . . . . . . . . . . . . . . . . . . . . 127<br />

N9316353 . . . . . . . . . . . . . . . . . . . . . . . . . . 127<br />

N9316354 . . . . . . . . . . . . . . . . . . . . . . . . . . 127<br />

N9316355 . . . . . . . . . . . . . . . . . . . . . . . . . . 127<br />

N9316356 . . . . . . . . . . . . . . . . . . . . . . . . . . 127<br />

N9316357 . . . . . . . . . . . . . . . . . . . . . . . . . . 127<br />

N9316358 . . . . . . . . . . . . . . . . . . . . . . . . . . 127<br />

N9316359 . . . . . . . . . . . . . . . . . . . . . . . . . . 129<br />

N9316360 . . . . . . . . . . . . . . . . . . . . . . . . . . 129<br />

N9316361 . . . . . . . . . . . . . . . . . . . . . . . . . . 129<br />

N9316386 . . . . . . . . . . . . . . . . . . . . . . . . . . 127<br />

N9316387 . . . . . . . . . . . . . . . . . . . . . . . . . . 127<br />

N9316388 . . . . . . . . . . . . . . . . . . . . . . . 98, 127<br />

N9316389 . . . . . . . . . . . . . . . . . . . . . . . . . . 127<br />

N9316390 . . . . . . . . . . . . . . . . . . . . . . . . . . 127<br />

N9316391 . . . . . . . . . . . . . . . . . . . . . . . . . . 127<br />

N9316392 . . . . . . . . . . . . . . . . . . . . 97-98, 127<br />

N9316393 . . . . . . . . . . . . . . . . . . . . 97-98, 127<br />

N9316394 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />

N9316395 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />

N9316396 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />

N9316398 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />

N9316399 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />

N9316400 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />

N9316401 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />

N9316402 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />

N9316403 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />

N9316404 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />

N9316405 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />

N9316406 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />

N9316407 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />

N9316408 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />

N9316409 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />

N9316410 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />

N9316411 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />

N9316412 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />

N9316413 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />

N9316416 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />

N9316417 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />

N9316418 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />

N9316419 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />

N9316420 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />

N9316421 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />

N9316422 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />

N9316423 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />

N9316425 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />

N9316426 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />

N9316427 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />

N9316428 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />

N9316429 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />

N9316430 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />

N9316431 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />

N9316432 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />

N9316433 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />

N9316434 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />

N9316435 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />

N9316436 . . . . . . . . . . . . . . . . . . . . . . . . . . 123<br />

N9316437 . . . . . . . . . . . . . . . . . . . . . . . . . . 123<br />

N9316438 . . . . . . . . . . . . . . . . . . . . . . . . . . 123<br />

N9316439 . . . . . . . . . . . . . . . . . . . . . . . . . . 123<br />

N9316440 . . . . . . . . . . . . . . . . . . . . . . . . . . 123<br />

N9316441 . . . . . . . . . . . . . . . . . . . . . . . . . . 123<br />

N9316442 . . . . . . . . . . . . . . . . . . . . . . . . . . 123<br />

N9316443 . . . . . . . . . . . . . . . . . . . . . . . . . . 123<br />

N9316444 . . . . . . . . . . . . . . . . . . . . . . . . . . 123<br />

N9316445 . . . . . . . . . . . . . . . . . . . . . . . . . . 123<br />

N9316446 . . . . . . . . . . . . . . . . . . . . . . . . . . 123<br />

N9316478 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />

N9316480 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />

N9316481 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />

N9316482 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />

N9316483 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />

N9316484 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />

N9316485 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />

N9316487 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />

N9316488 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />

N9316489 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />

N9316490 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />

N9316491 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />

N9316492 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />

N9316493 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />

N9316494 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />

N9316495 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />

N9316496 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />

N9316497 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />

N9316498 . . . . . . . . . . . . . . . . . . . . . . . . . . 124<br />

N9316520 . . . . . . . . . . . . . . . . . . . . . . . . . . 127<br />

N9316521 . . . . . . . . . . . . . . . . . . . . . . . . . . 127<br />

N9316534 . . . . . . . . . . . . . . . . . . . . . . . . . . 123<br />

N9316535 . . . . . . . . . . . . . . . . . . . . . . . . . . 123<br />

N9316536 . . . . . . . . . . . . . . . . . . . . . . . . . . 123<br />

N9316537 . . . . . . . . . . . . . . . . . . . . . . . . . . 123<br />

N9316538 . . . . . . . . . . . . . . . . . . . . . . . . . . 123<br />

N9316539 . . . . . . . . . . . . . . . . . . . . . . . . . . 123<br />

N9316540 . . . . . . . . . . . . . . . . . . . . . . . . . . 123<br />

N9316541 . . . . . . . . . . . . . . . . . . . . . . . . . . 123<br />

N9316542 . . . . . . . . . . . . . . . . . . . . . . . . . . 123<br />

N9316544 . . . . . . . . . . . . . . . . . . . . . . . . . . 129<br />

N9316545 . . . . . . . . . . . . . . . . . . . . . . . . . . 129<br />

N9316546 . . . . . . . . . . . . . . . . . . . . . . . . . . 129<br />

N9316547 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />

N9316548 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />

N9316549 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />

N9316550 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />

N9316551 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />

N9316552 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />

N9316553 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />

N9316554 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />

N9316555 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />

N9316556 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />

N9316557 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />

N9316558 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />

N9316559 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />

N9316560 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />

N9316561 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />

N9316562 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />

N9316563 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />

N9316564 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />

N9316565 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />

N9316566 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />

N9316567 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />

N9316568 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />

N9316569 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />

N9316570 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />

N9316571 . . . . . . . . . . . . . . . . . . . . . . . . . . 128<br />

N9316572 . . . . . . . . . . . . . . . . . . . . . . . . . . 127<br />

N9316573 . . . . . . . . . . . . . . . . . . . . . . . . . . 125<br />

N9316574 . . . . . . . . . . . . . . . . . . . . . . . . . . 125<br />

N9316575 . . . . . . . . . . . . . . . . . . . . . . . . . . 125<br />

N9316576 . . . . . . . . . . . . . . . . . . . . . . . . . . 125<br />

N9316577 . . . . . . . . . . . . . . . . . . . . . . . . . . 125<br />

N9316578 . . . . . . . . . . . . . . . . . . . . . . . . . . 125<br />

N9316579 . . . . . . . . . . . . . . . . . . . . . . . . . . 125<br />

N9316601 . . . . . . . . . . . . . . . . . . . . . . . . . . 129<br />

N9316602 . . . . . . . . . . . . . . . . . . . . . . . . . . 129<br />

N9316603 . . . . . . . . . . . . . . . . . . . . . . . . . . 129<br />

N9316604 . . . . . . . . . . . . . . . . . . . . . . . . . . 129<br />

N9316605 . . . . . . . . . . . . . . . . . . . . . . . . . . 129<br />

N9316606 . . . . . . . . . . . . . . . . . . . . . . . . . . 129<br />

N9316607 . . . . . . . . . . . . . . . . . . . . . . 129, 144<br />

N9316608 . . . . . . . . . . . . . . . . . . . . . . 129, 144<br />

N9316609 . . . . . . . . . . . . . . . . . . . . . . . . . . 129<br />

N9316610 . . . . . . . . . . . . . . . . . . . . . . . . . . 124<br />

N9316611 . . . . . . . . . . . . . . . . . . . . . . . . . . 124<br />

N9316612 . . . . . . . . . . . . . . . . . . . . . . . . . . 124<br />

N9316613 . . . . . . . . . . . . . . . . . . . . . . . . . . 124<br />

N9316614 . . . . . . . . . . . . . . . . . . . . . . . . . . 124<br />

N9316615 . . . . . . . . . . . . . . . . . . . . . . . . . . 124<br />

N9316616 . . . . . . . . . . . . . . . . . . . . . . . . . . 124<br />

N9316617 . . . . . . . . . . . . . . . . . . . . . . . . . . 124<br />

N9316618 . . . . . . . . . . . . . . . . . . . . . . . . . . 124<br />

N9316619 . . . . . . . . . . . . . . . . . . . . . . . . . . 124<br />

N9316620 . . . . . . . . . . . . . . . . . . . . . . . . . . 124<br />

N9316621 . . . . . . . . . . . . . . . . . . . . . . . . . . 124<br />

N9316622 . . . . . . . . . . . . . . . . . . . . . . . . . . 124<br />

N9316623 . . . . . . . . . . . . . . . . . . . . . . . . . . 124<br />

N9316624 . . . . . . . . . . . . . . . . . . . . . . . . . . 124<br />

N9316625 . . . . . . . . . . . . . . . . . . . . . . . . . . 124<br />

N9316626 . . . . . . . . . . . . . . . . . . . . . . . . . . 124<br />

N9316627 . . . . . . . . . . . . . . . . . . . . . . . . . . 124<br />

Part No. Page Part No. Page Part No. Page<br />

See page 4 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

See page 2 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong>


Index<br />

Index Part Number N9316628 – WE029013<br />

Part Number<br />

Part No. Page Part No. Page Part No. Page<br />

N9316628 . . . . . . . . . . . . . . . . . . . . . . . . . . 124<br />

N9316629 . . . . . . . . . . . . . . . . . . . . . . . . . . 124<br />

N9316630 . . . . . . . . . . . . . . . . . . . . . . . . . . 124<br />

N9316631 . . . . . . . . . . . . . . . . . . . . . . . . . . 124<br />

N9316632 . . . . . . . . . . . . . . . . . . . . . . . . . . 124<br />

N9316633 . . . . . . . . . . . . . . . . . . . . . . . . . . 124<br />

N9316634 . . . . . . . . . . . . . . . . . . . . . . . . . . 124<br />

N9316635 . . . . . . . . . . . . . . . . . . . . . . . . . . 124<br />

N9316636 . . . . . . . . . . . . . . . . . . . . . . . . . . 124<br />

N9316637 . . . . . . . . . . . . . . . . . . . . . . . . . . 124<br />

N9316638 . . . . . . . . . . . . . . . . . . . . . . . . . . 124<br />

N9316639 . . . . . . . . . . . . . . . . . . . . . . . . . . 124<br />

N9316640 . . . . . . . . . . . . . . . . . . . . . . . . . . 124<br />

N9316641 . . . . . . . . . . . . . . . . . . . . . . . . . . 124<br />

N9316642 . . . . . . . . . . . . . . . . . . . . . . . . . . 124<br />

N9316643 . . . . . . . . . . . . . . . . . . . . . . . . . . 124<br />

N9316644 . . . . . . . . . . . . . . . . . . . . . . . . . . 124<br />

N9316645 . . . . . . . . . . . . . . . . . . . . . . . . . . 124<br />

N9316646 . . . . . . . . . . . . . . . . . . . . . . . . . . 124<br />

N9316647 . . . . . . . . . . . . . . . . . . . . . . . . . . 124<br />

N9316648 . . . . . . . . . . . . . . . . . . . . . . . . . . 124<br />

N9316649 . . . . . . . . . . . . . . . . . . . . . . . . . . 124<br />

N9316650 . . . . . . . . . . . . . . . . . . . . . . . . . . 127<br />

N9316651 . . . . . . . . . . . . . . . . . . . . . . . . . . 127<br />

N9316652 . . . . . . . . . . . . . . . . . . . . . . . . . . 127<br />

N9316653 . . . . . . . . . . . . . . . . . . . . . . . . . . 127<br />

N9316654 . . . . . . . . . . . . . . . . . . . . . . . . . . 127<br />

N9316655 . . . . . . . . . . . . . . . . . . . . . . . . . . 127<br />

N9316656 . . . . . . . . . . . . . . . . . . . . . . . . . . 127<br />

N9316657 . . . . . . . . . . . . . . . . . . . . . . . . . . 127<br />

N9316658 . . . . . . . . . . . . . . . . . . . . . . . . . . 127<br />

N9316659 . . . . . . . . . . . . . . . . . . . . . . . . . . 127<br />

N9316660 . . . . . . . . . . . . . . . . . . . . . . . . . . 127<br />

N9316661 . . . . . . . . . . . . . . . . . . . . . . . . . . 126<br />

N9316662 . . . . . . . . . . . . . . . . . . . . . . . . . . 126<br />

N9316663 . . . . . . . . . . . . . . . . . . . . . . . . . . 126<br />

N9316664 . . . . . . . . . . . . . . . . . . . . . . . . . . 126<br />

N9316665 . . . . . . . . . . . . . . . . . . . . . . . . . . 126<br />

N9316666 . . . . . . . . . . . . . . . . . . . . . . . . . . 126<br />

N9316667 . . . . . . . . . . . . . . . . . . . . . . . . . . 126<br />

N9316668 . . . . . . . . . . . . . . . . . . . . . . . . . . 126<br />

N9316669 . . . . . . . . . . . . . . . . . . . . . . . . . . 126<br />

N9316670 . . . . . . . . . . . . . . . . . . . . . . . . . . 126<br />

N9316671 . . . . . . . . . . . . . . . . . . . . . . . . . . 126<br />

N9316672 . . . . . . . . . . . . . . . . . . . . . . . . . . 126<br />

N9316673 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />

N9316674 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />

N9316675 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />

N9316676 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />

N9316677 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />

N9316678 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />

N9316679 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />

N9316680 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />

N9316681 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />

N9316682 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />

N9316684 . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />

PELA1005 . . . . . . . . . . . . . . . . . . . . . . . . . . 380<br />

PELA1006 . . . . . . . . . . . . . . . . . . . . . . . . . . 380<br />

PELA1008 . . . . . . . . . . . . . . . . . . . . . . . . . . 380<br />

PELA1013 . . . . . . . . . . . . . . . . . . . . . . . . . . 380<br />

PELA1014 . . . . . . . . . . . . . . . . . . . . . . . . . . 380<br />

PELA1015 . . . . . . . . . . . . . . . . . . . . . . . . . . 380<br />

PELA1022 . . . . . . . . . . . . . . . . . . . . . . . . . . 381<br />

PELA9010 . . . . . . . . . . . . . . . . . . . . . . . . . . 396<br />

PELA9012 . . . . . . . . . . . . . . . . . . . . . . . . . . 396<br />

PELA9013 . . . . . . . . . . . . . . . . . . . . . . . . . . 396<br />

PELA9018 . . . . . . . . . . . . . . . . . . . . . . . . . . 396<br />

PELA9019 . . . . . . . . . . . . . . . . . . . . . . . . . . 396<br />

PELA9020 . . . . . . . . . . . . . . . . . . . . . . . . . . 396<br />

PELA9021 . . . . . . . . . . . . . . . . . . . . . . . . . . 396<br />

PELA9038 . . . . . . . . . . . . . . . . . . . . . . . . . . 381<br />

PELA9039 . . . . . . . . . . . . . . . . . . . . . . . . . . 381<br />

PELA9040 . . . . . . . . . . . . . . . . . . . . . . . . . . 384<br />

PELA9042 . . . . . . . . . . . . . . . . . . . . . . . . . . 381<br />

PELA9057 . . . . . . . . . . . . . . . . . . . . . . . . . . 396<br />

PELA9058 . . . . . . . . . . . . . . . . . . . . . . . . . . 396<br />

S2000203 . . . . . . . . . . . . . . . . . . . . . . . . . . 178<br />

S2000204 . . . . . . . . . . . . . . . . . . . . . . . . . . 178<br />

S2000205 . . . . . . . . . . . . . . . . . . . . . . . . . . 178<br />

S2000206 . . . . . . . . . . . . . . . . . . . . . . . . . . 178<br />

S2700055 . . . . . . . . . . . . . . . . . . . . . . . . . . 332<br />

S2701017 . . . . . . . . . . . . . . . . . . . . . . . . . . 138<br />

S2701116 . . . . . . . . . . . . . . . . . . . . . . . . . . 138<br />

S2701610 . . . . . . . . . . . . . . . . . . . . . . . . . . 137<br />

S5010013 . . . . . . . . . . . . . . . . . . . . . . 177, 331<br />

S5010015 . . . . . . . . . . . . . . . . . . . . . . 177, 331<br />

S5010016 . . . . . . . . . . . . . . . . . . . . . . 177, 331<br />

S5010017 . . . . . . . . . . . . . . . . . . . . . . 177, 331<br />

S5010018 . . . . . . . . . . . . . . . . . . . . . . 177, 331<br />

S5010019 . . . . . . . . . . . . . . . . . . . . . . 177, 331<br />

S5010020 . . . . . . . . . . . . . . . . . . . . . . 177, 331<br />

S5010021 . . . . . . . . . . . . . . . . . . . . . . 177, 331<br />

S5010022 . . . . . . . . . . . . . . . . . . . . . . 177, 331<br />

S5010023 . . . . . . . . . . . . . . . . . . . . . . 177, 331<br />

S5010024 . . . . . . . . . . . . . . . . . . . . . . 177, 331<br />

S5010025 . . . . . . . . . . . . . . . . . . 137, 177, 331<br />

S5010030 . . . . . . . . . . . . . . . . . . 137, 177, 331<br />

S5010031 . . . . . . . . . . . . . . . . . . . . . . 177, 331<br />

S5010032 . . . . . . . . . . . . . . . . . . . . . . 177, 331<br />

S5010033 . . . . . . . . . . . . . . . . . . . . . . 177, 331<br />

S5010034 . . . . . . . . . . . . . . . . . . . . . . 177, 331<br />

S5010035 . . . . . . . . . . . . . . . . . . . . . . 177, 331<br />

S5010036 . . . . . . . . . . . . . . . . . . . . . . 177, 331<br />

S5010037 . . . . . . . . . . . . . . . . . . . . . . 177, 331<br />

S5010038 . . . . . . . . . . . . . . . . . . . . . . 177, 331<br />

S5010039 . . . . . . . . . . . . . . . . . . . . . . 177, 331<br />

S5010040 . . . . . . . . . . . . . . . . . . . . . . 177, 331<br />

S5010041 . . . . . . . . . . . . . . . . . . . . . . 177, 331<br />

S9000070 . . . . . . . . . . . . . . . . . . . . . . 174, 329<br />

S9000075 . . . . . . . . . . . . . . . . . . . . . . 174, 329<br />

S9000090 . . . . . . . . . . . . . . . . . . . . . . 174, 329<br />

S9000095 . . . . . . . . . . . . . . . . . . . . . . 174, 329<br />

S9000160 . . . . . . . . . . . . . . . . . . . . . . 176, 330<br />

S9000165 . . . . . . . . . . . . . . . . . . . . . . 176, 330<br />

W1006057 . . . . . . . . . . . . . . . . . . . . . . . . . 192<br />

W1007468 . . . . . . . . . . . . . . . . . . . . . . . . . 205<br />

W1007493 . . . . . . . . . . . . . . . . . . . . . . . . . 208<br />

W1008384 . . . . . . . . . . . . . . . . . . . . . . . . . 205<br />

W1008680 . . . . . . . . . . . . . . . . . . . . . . . . . 192<br />

W1010598 . . . . . . . . . . . . . . . . . . . . . . . . . 190<br />

W1010620 . . . . . . . . . . . . . . . . . . . . . . . . . 190<br />

W1012406 . . . . . . . . . . . . . . . . . . . . . 195, 205<br />

W1012408 . . . . . . . . . . . . . . . . . . . . . . . . . 205<br />

W1012409 . . . . . . . . . . . . . . . . . . . . . . . . . 205<br />

W1012410 . . . . . . . . . . . . . . . . . . . . . . . . . 205<br />

W1012771 . . . . . . . . . . . . . . . . . . . . . . . . . 192<br />

W1013195 . . . . . . . . . . . . . . . . . . . . . . . . . 190<br />

W1013266 . . . . . . . . . . . . . . . . . . . . . 195, 205<br />

W1013361 . . . . . . . . . . . . . . . . . . . . . . . . . 190<br />

W1013545 . . . . . . . . . . . . . . . . . . . . . 195, 205<br />

W1013691 . . . . . . . . . . . . . . . . . . . . . . . . . 206<br />

W1015115 . . . . . . . . . . . . . . . . . . . . . . . . . 206<br />

W1017871 . . . . . . . . . . . . . . . . . . . . . . . . . 190<br />

W1020331 . . . . . . . . . . . . . . . . . . . . . 202, 205<br />

W1020668 . . . . . . . . . . . . . . . . . . . . . . . . . 205<br />

W1020672 . . . . . . . . . . . . . . . . . . . . . . . . . 205<br />

W1020996 . . . . . . . . . . . . . . . . . . 201-202, 205<br />

WE012411 . . . . . . . . . . . . . . . . . . . . . . . . . 205<br />

WE012687 . . . . . . . . . . . . . . . . . . . . . . . . . 193<br />

WE012989 . . . . . . . . . . . . . . . . . . . . . . . . . 189<br />

WE013060 . . . . . . . . . . . . . . . . . . . . . 201, 204<br />

WE013087 . . . . . . . . . . . . . . . . . . . . . . . . . 189<br />

WE013119 . . . . . . . . . . . . . . . . . . . . . 201, 204<br />

WE013829 . . . . . . . . . . . . . . . . . . . . . . . . . 204<br />

WE014034 . . . . . . . . . . . . . . . . . . . . . . . . . 202<br />

WE014081 . . . . . . . . . . . . . . . . . . . . . 201, 204<br />

WE014777 . . . . . . . . . . . . . . . . . . . . . . . . . 190<br />

WE015554 . . . . . . . . . . . . . . . . . . . . . . . . . 205<br />

WE015772 . . . . . . . . . . . . . . . . . . . . . . . . . 191<br />

WE016558 . . . . . . . . . . . . . . . . . . . . . . . . . 190<br />

WE017142 . . . . . . . . . . . . . . . . . . . . . . . . . 189<br />

WE017603 . . . . . . . . . . . . . . . . . . . . . . . . . 192<br />

WE018034 . . . . . . . . . . . . . . . . . . . . . 190, 193<br />

WE018076 . . . . . . . . . . . . . . . . . . . . . . . . . 191<br />

WE018079 . . . . . . . . . . . . . . . . . . . . . . . . . 191<br />

WE018355 . . . . . . . . . . . . . . . . . . . . . . . . . 191<br />

WE021074 . . . . . . . . . . . . . . . . . . . . . . . . . 193<br />

WE021137 . . . . . . . . . . . . . . . . . . . . . 189, 193<br />

WE021140 . . . . . . . . . . . . . . . . . . . . . 189, 193<br />

WE021816 . . . . . . . . . . . . . . . . . . . . . 193, 205<br />

WE022567 . . . . . . . . . . . . . . . . . . . . . . . . . 193<br />

WE023257 . . . . . . . . . . . . . . . . . . . . . . . . . 192<br />

WE023935 . . . . . . . . . . . . . . . . . . . . . . . . . 192<br />

WE023948 . . . . . . . . . . . . . . . . . . . . . 193, 195<br />

WE023951 . . . . . . . . . . . . . . . . . 193, 195, 201<br />

WE024354 . . . . . . . . . . . . . . . . . . . . . . . . . 192<br />

WE024371 . . . . . . . . . . . . . . . . . . . . . 196, 201<br />

WE024372 . . . . . . . . . . . . . . . . . 193, 196, 201<br />

WE024375 . . . . . . . . . . . . . . . . . . . . . 193, 196<br />

WE024782 . . . . . . . . . . . . . . . . . . . . . . . . . 200<br />

WE025221. . . . . . . . . . . . . . . . . . . . . . 201-202<br />

WE025239. . . . . . . . . . . . . . . . . . . . . . 201-202<br />

WE027005 . . . . . . . . . . . . . . . . . . . . . . . . . 195<br />

WE027030 . . . . . . . . . . . . . . . . . . . . . . . . . 195<br />

WE027567 . . . . . . . . . . . . . . . . . . . . . . . . . 192<br />

WE027802 . . . . . . . . . . . . . . . . . . . . . 189, 193<br />

WE027803 . . . . . . . . . . . . . . . . . . . . . 189, 193<br />

WE028426 . . . . . . . . . . . . . . . . . . . . . . . . . 191<br />

WE028427 . . . . . . . . . . . . . . . . . . . . . . . . . 191<br />

WE028428 . . . . . . . . . . . . . . . . . . . . . . . . . 191<br />

WE028439 . . . . . . . . . . . . . . . . . . . . . . . . . 192<br />

WE029011 . . . . . . . . . . . . . . . . . . . . . . . . . 190<br />

WE029013 . . . . . . . . . . . . . . . . . . . . . . . . . 192<br />

428


Atomic Absorption Index<br />

Alphabetical<br />

Amalgamation System Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . .26<br />

AutoPrep 50 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10<br />

Autosampler Supplies and Accessories . . . . . . . . . . . . . . . . . . . . .8-12<br />

Autosampler Flame/FIAS Probes . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9<br />

Sampling Probe Assemblies and Components . . . . . . . . . . . . . . . .9<br />

Sampling Probe Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9<br />

Autosampler Flame/FIAS Trays and Vessels . . . . . . . . . . . . . . . . . . . . .8<br />

Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8<br />

Rinsing Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8<br />

Sample Trays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8<br />

Sample Vessels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8<br />

Tubes and Beakers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8<br />

Dilution System Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10<br />

AutoPrep 50 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10<br />

Graphite Furnace Autosampler Supplies . . . . . . . . . . . . . . . . . . . .11-12<br />

Autosampler Sample Cups . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11<br />

Autosampler Trays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11<br />

Check Valves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11<br />

Ferrule Kits and Tubing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12<br />

Reagent Containers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12<br />

Sampling Capillaries . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12<br />

Burner Heads . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13-15<br />

AAnalyst 100/200/300/400/700/800 . . . . . . . . . . . . . . . . . . . . . . . .13<br />

Models 1100(B), 2100, and 4100 . . . . . . . . . . . . . . . . . . . . . . . . . . .15<br />

Models 2280, 2380, 3030(B), 3100, 3110, 3300,<br />

4000, 5000, and 5100 PC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14<br />

Burner System Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13-20<br />

AAnalyst 100/200/300/400/700/800 . . . . . . . . . . . . . . . . . . . . . . . .13<br />

Burner Heads . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13<br />

Burner System Components . . . . . . . . . . . . . . . . . . . . . . . . . . . .13<br />

Drain Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13<br />

Models 1100(B), 2100, and 4100 . . . . . . . . . . . . . . . . . . . . . . . . . . .15<br />

Burner Heads . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15<br />

Models 2280, 2380, 3030(B), 3100, 3110, 3300,<br />

4000, 5000, and 5100 PC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14<br />

Cable and Pin Assemblies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14<br />

Nebulizer Assemblies and Components Quick Reference . . . . . . . . . . .17<br />

Plastic Body Nebulizers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17<br />

Stainless Steel Body Nebulizers . . . . . . . . . . . . . . . . . . . . . . . . . .17<br />

Nebulizers and Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18-20<br />

Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18<br />

GemTip Nebulizers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18<br />

High-Sensitivity Nebulizer with Pt/Ir Capillary . . . . . . . . . . . . . . . .19<br />

High-Sensitivity Nebulizers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19<br />

Stainless Steel Body Nebulizers and Parts . . . . . . . . . . . . . . . . . .20<br />

Contact Cylinders . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31, 34<br />

HGA Contact Cylinders . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31<br />

THGA Contact Cylinders . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34<br />

Flow Injection Sampling Supplies . . . . . . . . . . . . . . . . . . . . . . . .21-28<br />

FIAS and FIMS Parts and Supplies . . . . . . . . . . . . . . . . . . . . . . . .22-23<br />

FIAS Cells and Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22<br />

FIMS Cells and Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22<br />

Gas/Liquid Separator Consumables . . . . . . . . . . . . . . . . . . . . . . .22<br />

Pump Magazines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23<br />

Spare Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23<br />

Switching Valves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23<br />

FIAS and FIMS Tubing Adapters and Connectors . . . . . . . . . . . . . . . . .24<br />

Adapters with Internal Threads . . . . . . . . . . . . . . . . . . . . . . . . . .24<br />

Adapters with External Threads . . . . . . . . . . . . . . . . . . . . . . . . . .24<br />

Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24<br />

FIAS and FIMS Tubing and Supplies . . . . . . . . . . . . . . . . . . . . . . . . . .25<br />

Peristaltic Pump Tubing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25<br />

PTFE Tubing, Screw Connectors, and O-Rings . . . . . . . . . . . . . . .25<br />

Sample Loops . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25<br />

Flow Injection Amalgamation System . . . . . . . . . . . . . . . . . . . . . . . . .26<br />

Amalgamation System and Supplies . . . . . . . . . . . . . . . . . . . . . .26<br />

Flow Injection Analysis and Mercury Systems . . . . . . . . . . . . . . . . . . .21<br />

Flow Injection Furnace Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27<br />

FIAS-Furnace Coupling Kit and Supplies . . . . . . . . . . . . . . . . . . . .27<br />

Flow Injection Preconcentration Kit and Supplies . . . . . . . . . . . . . . . . .28<br />

Flow Injection Sampling Valves and Supplies . . . . . . . . . . . . . . . .28<br />

Peristaltic Pump Tubing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28<br />

Preconcentration Columns . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28<br />

PTFE Tubing Assemblies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28<br />

Tubing Adapters and Connectors . . . . . . . . . . . . . . . . . . . . . . . . .28<br />

Graphite Furnace Tubes and Supplies . . . . . . . . . . . . . . . . . . . . .31-35<br />

HGA Graphite Contact Cylinders, Tubes, and Supplies . . . . . . . . . .31-32<br />

Circulatory Cooling System . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33<br />

Contact Cylinders . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31<br />

HGA Graphite Cooling Systems and Quartz Windows . . . . . . . . . . .33<br />

L'vov Platforms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31<br />

Matrix Modifiers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32<br />

Pyrocoated Graphite Tubes (Grooved) . . . . . . . . . . . . . . . . . . . . . .32<br />

Pyrocoated Graphite Tubes with Integrated Platform . . . . . . . . . . .32<br />

Quartz Window Components . . . . . . . . . . . . . . . . . . . . . . . . . . . .33<br />

Quartz Windows . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35<br />

Uncoated Graphite Tubes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32<br />

THGA Graphite Contact Cylinders, Tubes, and Supplies . . . . . . . . .34-35<br />

Contact Cylinders . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34<br />

Graphite Tubes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34<br />

Matrix Modifiers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35<br />

Spare Parts and Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35<br />

Graphite Tubes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32, 34<br />

HGA Graphite Tubes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32<br />

THGA Graphite Tubes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34<br />

High Pressure Asher System Supplies . . . . . . . . . . . . . . . . . . . . .51-52<br />

Laboratory Products . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .36-38<br />

Filters, Regulators, and Supplies . . . . . . . . . . . . . . . . . . . . . . . . . .36-38<br />

Filters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .36<br />

Flash Arrestor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .37<br />

Hose Assemblies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .37<br />

Instrument Filters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .37<br />

MiniDispenser . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .37<br />

Regulators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .38<br />

Venting System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .38<br />

Lamps for Atomic Absorption . . . . . . . . . . . . . . . . . . . . . . . . . . . .39-48<br />

Lumina Hollow Cathode Lamp Coded Adapters . . . . . . . . . . . . . . . . . .43<br />

Coded Lumina Adapters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .43<br />

Lumina Hollow Cathode Lamps . . . . . . . . . . . . . . . . . . . . . . . . . . .39-43<br />

Features and Benefits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .39<br />

Lumina Lamps and Lamps with Adapters . . . . . . . . . . . . . . . .40-41<br />

Lumina Multi-Element Hollow Cathode Lamps . . . . . . . . . . . . . . .42<br />

Non-Coded Hollow Cathode Lamp Adapters . . . . . . . . . . . . . . . . . . . .44<br />

Lamp Plug Adapters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .44<br />

Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .45<br />

Background Corrector Sources . . . . . . . . . . . . . . . . . . . . . . . . . .45<br />

Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .45<br />

System 2 EDL Lamp Supplies and Accessories . . . . . . . . . . . . . . . . . .48<br />

EDL Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .48<br />

EDL Driver Assemblies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .48<br />

System 2 EDL Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . .48<br />

Alphabetical Atomic Absorption Index<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

429


Atomic Absorption Index<br />

Alphabetical<br />

System 2 EDL Lamps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .46-47<br />

Features and Benefits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .46<br />

System 2 EDL Lamps and Adapters . . . . . . . . . . . . . . . . . . . . . . .47<br />

Matrix Modifiers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .67<br />

Mercury/Hydride System and Supplies . . . . . . . . . . . . . . . . . . . . . . .49<br />

MHS, Quartz Cells, and Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . .49<br />

Quartz Cells . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .49<br />

MiniDispenser . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .37<br />

Multiwave Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .53-55<br />

PerkinElmer Pure Atomic Absorption Standards . . . . . . . . . . . . . . .66-67<br />

Alternate Trace Metal Drinking<br />

CLP Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .66<br />

Contract Required Detection Limits (CRDL) Standard . . . . . . . . . . .67<br />

Groundwater and Wastewater<br />

Pollution Control Check Standards . . . . . . . . . . . . . . . . . . . . . . . .67<br />

Pollution and Wastewater Standards . . . . . . . . . . . . . . . . . . . . . .66<br />

Reagents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .67<br />

Tubing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24-25<br />

Adapters and Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24<br />

Peristaltic Pump Tubing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25<br />

PTFE Tubing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25<br />

Atomic Absorption Index Alphabetical<br />

Multiwave 3000 Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .57-64<br />

Rotor 1 DRY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .62<br />

Rotor 8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .57-59<br />

Rotor 8 EVAP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .62<br />

Rotor 8 SOLV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .63-64<br />

Rotor 16 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .60-61<br />

Nebulizers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17-20<br />

Gemtip . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18<br />

High-Sensitivity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19<br />

Quick Reference . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17<br />

Stainless Steel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20<br />

Sample Cups and Vessels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8, 11<br />

Autosampler Vessels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8<br />

Graphite Furnace Autosampler Sample Cups . . . . . . . . . . . . . . . . . . .11<br />

Sample Preparation Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . .50-64<br />

High Pressure Asher System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50<br />

High Pressure Asher System Supplies . . . . . . . . . . . . . . . . . . . . . .51-52<br />

Heat Trays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .51<br />

Reaction Vessel Racks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .51<br />

Reaction Vessel Sets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .51<br />

Reaction Vessels and Lids . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .51<br />

Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .52<br />

Multiwave . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .53-55<br />

Multiwave Accessories and Supplies . . . . . . . . . . . . . . . . . . . .53-55<br />

Reaction Vessel Assemblies . . . . . . . . . . . . . . . . . . . . . . . . . . . . .54<br />

Reaction Vessel Racks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .55<br />

Rotors and Rotor Assemblies . . . . . . . . . . . . . . . . . . . . . . . . . . . .55<br />

Multiwave 3000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .56-64<br />

Multiwave 3000 Accessories and Supplies . . . . . . . . . . . . . . .56-64<br />

Multiwave 3000 Digestion Rotors . . . . . . . . . . . . . . . . . . . . . . . . .57-61<br />

Rotor 8 Consumables and Vessels . . . . . . . . . . . . . . . . . . . . .57-58<br />

Rotor 8 Spare Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .59<br />

Rotor 16 Consumables and Vessels . . . . . . . . . . . . . . . . . . . . . . .60<br />

Rotor 16 Spare Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .61<br />

Multiwave 3000 Drying and Evaporation Rotors . . . . . . . . . . . . . . . . .62<br />

Rotor 1 DRY Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .62<br />

Rotor 8 EVAP Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .62<br />

Multiwave 3000 Solvent Extraction Rotors . . . . . . . . . . . . . . . . . . . . .63<br />

Rotor 8 SOLV Consumables and Vessels . . . . . . . . . . . . . . . . . . .63<br />

Multiwave 3000 Solvent Extraction Rotors and System Spare Parts . . .64<br />

Rotor 8 SOLV Spare Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .64<br />

System Spare Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .64<br />

Sampling Probes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9<br />

Assemblies and Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9<br />

Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .65-69<br />

PerkinElmer Pure Atomic Absorption Standards . . . . . . . . . . . . . . .66-69<br />

Single-Element Calibration Standards . . . . . . . . . . . . . . . . . . .68-69<br />

WinLab32 Software for AA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .70-71<br />

Software for Atomic Absorption Analysis . . . . . . . . . . . . . . . . . . . .70-71<br />

Windows . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33, 35<br />

HGA Quartz Windows . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33<br />

THGA Quartz Windows . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35<br />

430


Elemental Analysis Index<br />

Alphabetical<br />

2400 Series II Analysis Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .76<br />

Analysis Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .76<br />

CHN Analysis Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .76<br />

CHNS Analysis Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .76<br />

Oxygen Analysis Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .76<br />

Calibration Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .80<br />

Gas Pressure Regulators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .77<br />

Laboratory Products . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .77<br />

For the 2400/2410 Series II Analyzers . . . . . . . . . . . . . . . . . . . . . . . .77<br />

Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .77<br />

Gas Lines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .77<br />

Gas Pressure Regulators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .77<br />

Printer Kit and Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .77<br />

Packing Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .78-79<br />

Reagents, Tubes, and Receptacles . . . . . . . . . . . . . . . . . . . . . . . .78-79<br />

2400 Tubes and Reagent Kits . . . . . . . . . . . . . . . . . . . . . . . . . . .78<br />

Packing Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .78<br />

Receptacles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .79<br />

Tubes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .79<br />

Reagents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .78<br />

Sample Handling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .80<br />

Calibration Standards, Capsules, and Supplies . . . . . . . . . . . . . . . . . .80<br />

Calibration Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .80<br />

Sample Capsules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .80<br />

Sample Handling Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . .80<br />

Sealers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .80<br />

Spare Parts and Tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .81-83<br />

Autoinjector and Fitting Spares . . . . . . . . . . . . . . . . . . . . . . . . . . . . .81<br />

Autoinjector Spares . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .81<br />

Fittings for Combustion<br />

and Reduction Tubes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .81<br />

Fittings and Tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .82<br />

Fittings for Scrubber . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .82<br />

Spare Parts for 2400/2410 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .82<br />

Tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .82<br />

Valve Spares . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .83<br />

Ultramicrobalance Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .375<br />

Alphabetical Elemental Analysis Index<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

431


Gas Chromatography Index<br />

Alphabetical<br />

Gas Chromatography Index Alphabetical<br />

Autosampler Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .88-90<br />

Syringes and Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .88<br />

Autosampler Replacement Parts . . . . . . . . . . . . . . . . . . . . . . . . .88<br />

Miscellaneous Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . .88<br />

Syringes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .88<br />

Vial Crimping Tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .90<br />

Crimping Tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .90<br />

Vials, Caps, and Septa . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .89<br />

Crimp Caps and Septa . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .89<br />

Crimp Top Sample Vials . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .89<br />

Screw Top Sample Vials and Caps . . . . . . . . . . . . . . . . . . . . . . . .89<br />

Vial Holder Racks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .89<br />

Waste Vials . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .89<br />

Capillary Column Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . .92-95<br />

Adapter Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .92<br />

Connectors and Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .93<br />

Column Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .93<br />

Tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .93<br />

Uncoated Deactivated Fused-Silica Capillary Tubing . . . . . . . . . . .93<br />

Universal Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .93<br />

Ferrules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .94<br />

Graphite and Vespel Ferrules . . . . . . . . . . . . . . . . . . . . . . . . . . . .94<br />

SilTite Ferrules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .94<br />

Fittings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .95<br />

Swagelok Fittings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .95<br />

Capillary Column Applications . . . . . . . . . . . . . . . . . . . . . . . . . .99-119<br />

Environmental . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .99-109<br />

Food and Flavors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .110-112<br />

Forensics/Clinical Toxicology . . . . . . . . . . . . . . . . . . . . . . . . . . .113-115<br />

Industrial Chemicals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .116-118<br />

Petroleum . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .119<br />

Capillary Columns . . . . . . . . . . . . . . . . . . . . . . . . . .91, 97-98, 120-130<br />

Capillary Columns . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .91<br />

U.S. EPA Methods . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .97-98<br />

U.S. EPA Drinking Water Test Methods . . . . . . . . . . . . . . . . . . . . .97<br />

U.S. EPA Organic Chemical Analysis Waste Water Methods . . . . . .97<br />

U.S. EPA Solid Waste Test Methods . . . . . . . . . . . . . . . . . . . . . . .98<br />

Phase Cross-Reference . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .120<br />

PerkinElmer Elite Series Capillary Columns . . . . . . . . . . . . . . . .121-128<br />

Elite-1ht (High-Temp) Dimethylpolysiloxane . . . . . . . . . . . . . . . . .121<br />

Elite-1 Dimethylpolysiloxane . . . . . . . . . . . . . . . . . . . . . . . . . . .121<br />

Elite-5 Amine . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .122<br />

Elite-5ht (High-Temp) (5% – Diphenyl) – Dimethylpolysiloxane . .122<br />

Elite-5ms (5% – Diphenyl) – Dimethylpolysiloxane . . . . . . . . . . .122<br />

Elite-5 (5% – Diphenyl) – Dimethylpolysiloxane . . . . . . . . . . . . .122<br />

Elite-17 (50% – Phenyl) – Methylpolysiloxane . . . . . . . . . . . . . .123<br />

Elite-17ht (High-Temp) (50% – Phenyl) – Methylpolysiloxane . . .123<br />

Elite-17ms (Low Bleed) (50% – Phenyl) – Methylpolysiloxane . . .123<br />

Elite-35 (35% – Diphenyl) – Dimethylpolysiloxane . . . . . . . . . . .123<br />

Elite-35ms (35% – Phenyl) – Methylpolysiloxane . . . . . . . . . . . .123<br />

Elite-200 Trifluoropropylmethyl Polysiloxane . . . . . . . . . . . . . . . .124<br />

Elite-225 (50% – Cyanopropylmethyl) –<br />

Phenylmethylpolysiloxane . . . . . . . . . . . . . . . . . . . . . . . . . . . . .124<br />

Elite-502.2 Specialty Phase for<br />

Analysis of Volatiles (U.S. EPA 502.2) . . . . . . . . . . . . . . . . . . . . .124<br />

Elite-608 Specialty Phase for<br />

Semivolatile Pesticides (U.S. EPA 608) . . . . . . . . . . . . . . . . . . . .124<br />

Elite-624 Specialty Phase for<br />

Analysis of Volatiles (U.S. EPA 624) . . . . . . . . . . . . . . . . . . . . . .125<br />

Elite-1301 (6% – Cyanopropylphenyl) – Methylpolysiloxane . . . .125<br />

Elite-1701 (14% – Cyanopropylphenyl) – Methylpolysiloxane . . .125<br />

Elite-BAC Blood Alcohol Analysis Columns for GC<br />

and High-Speed Headspace Gas Chromatography . . . . . . . . . . .125<br />

Elite-Betacydex Betacyclodextrin for Chiral Separations . . . . . . . .125<br />

Elite-CLPesticides . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .126<br />

Elite-CLPesticides 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .126<br />

Elite-FFAP Nitroterephthalic Acid Modified Polyethylene<br />

Glycol (Bonded) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .127<br />

Elite-HT SimDist for High-Temperature Simulated Distillation . . . .127<br />

Elite-MTBE Low Polarity Stationary Phase . . . . . . . . . . . . . . . . .127<br />

Elite-PONA Dimethylpolysiloxane Processed<br />

for Detailed Analysis of Petroleum Naphtha . . . . . . . . . . . . . . . .127<br />

Elite-RX for Analysis of Drugs of Abuse . . . . . . . . . . . . . . . . . . .127<br />

Elite-SimDist Dimethylpolysiloxane Processed<br />

for Simulated Distillation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .127<br />

Elite-TPH Specialty Phase for Analysis of<br />

Total Petroleum Hydrocarbons . . . . . . . . . . . . . . . . . . . . . . . . . .127<br />

Elite-VMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .127<br />

Elite-Volatiles Specialty Phase for Analysis of Volatile<br />

Organic Compounds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .127<br />

Elite-XLB Specialty Phase for GC/MS<br />

with Exceptionally Low Bleed . . . . . . . . . . . . . . . . . . . . . . . . . . .127<br />

Elite-MWAX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .128<br />

Elite-WAX ETR (Extended Temperature Range)<br />

Polyethylene Glycol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .128<br />

Elite-WAX Polyethylene Glycol . . . . . . . . . . . . . . . . . . . . . . . . . .128<br />

PerkinElmer Elite Series Guard and PLOT Columns . . . . . . . . . . . . . .129<br />

Elite-Alumina/KCI* PLOT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .129<br />

Elite-Alumina PLOT Phase for<br />

Analysis of Light Hydrocarbons . . . . . . . . . . . . . . . . . . . . . . . . .129<br />

Elite-Cyclosil B PLOT for Chiral Separations . . . . . . . . . . . . . . . .129<br />

Elite-Molesieve PLOT Phase for<br />

Analysis of Permanent Gases . . . . . . . . . . . . . . . . . . . . . . . . . .129<br />

Elite-Q PLOT Phase for Analysis of<br />

Light Gases and Hydrocarbons . . . . . . . . . . . . . . . . . . . . . . . . .129<br />

Elite Guard Columns . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .129<br />

PerkinElmer Packed Columns . . . . . . . . . . . . . . . . . . . . . . . . . . . . .130<br />

Packed Columns . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .130<br />

Detectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .131-141<br />

Electron Capture Detectors (ECD) . . . . . . . . . . . . . . . . . . . . . . . . . . .131<br />

Add-On Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .131<br />

Column Adapters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .131<br />

ECD Wipe Test Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .131<br />

Flame Ionization Detector (FID) Auto-Ignite . . . . . . . . . . . . . . . . . . . .132<br />

Add-On Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .132<br />

Auto-Ignite FID Replacement Parts . . . . . . . . . . . . . . . . . . . . . . .132<br />

Detector Series Operation Kit . . . . . . . . . . . . . . . . . . . . . . . . . . .132<br />

FID Miscellaneous Accessories . . . . . . . . . . . . . . . . . . . . . . . . .132<br />

Flame Ionization Detector (FID) External Igniter . . . . . . . . . . . . . . . . .133<br />

Add-On Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .133<br />

Replacement Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .133<br />

Flame Ionization Detector (FID) Replacement Parts . . . . . . . . . . . . . .134<br />

Catalytic Reactor Accessory . . . . . . . . . . . . . . . . . . . . . . . . . . . .134<br />

Catalytic Reactor Replacement Parts . . . . . . . . . . . . . . . . . . . . .134<br />

Miscellaneous Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . .134<br />

Flame Photometric Detector (FPD) . . . . . . . . . . . . . . . . . . . . . . . . . .135<br />

Add-On Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .135<br />

Mass Spectrometer Detector . . . . . . . . . . . . . . . . . . . . . . . . . .136-138<br />

Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .137<br />

Inner Source Replacement Parts . . . . . . . . . . . . . . . . . . . . . . . .137<br />

Ionizer Replacement Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . .137<br />

Manuals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .137<br />

Miscellaneous Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . .137<br />

Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .138<br />

Transfer Line . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .138<br />

Upgrade Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .138<br />

Nitrogen Phosphorus Detector (NPD) . . . . . . . . . . . . . . . . . . . . . . . .139<br />

Add-On Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .139<br />

Column Adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .139<br />

Replacement Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .139<br />

432


Gas Chromatography Index<br />

Alphabetical<br />

Photoionization Detector (PID) . . . . . . . . . . . . . . . . . . . . . . . . . . . . .140<br />

Add-On Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .140<br />

Detector Series Operation Kits . . . . . . . . . . . . . . . . . . . . . . . . . .140<br />

Miscellaneous Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . .140<br />

Replacement Lamps and Parts . . . . . . . . . . . . . . . . . . . . . . . . .140<br />

Thermal Conductivity Detector (TCD) . . . . . . . . . . . . . . . . . . . . . . . .141<br />

Add-On Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .141<br />

Column Adapters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .141<br />

TCD/FID Series Operation Kit . . . . . . . . . . . . . . . . . . . . . . . . . . .141<br />

Ferrules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .94<br />

Graphite . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .94<br />

Graphite/Vespel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .94<br />

SilTite . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .94<br />

Filters and Traps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .163<br />

Fittings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .95<br />

Capillary Columns . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .95<br />

Swagelok Fittings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .95<br />

Flow Meters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .167<br />

Digital Flow Meters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .167<br />

Electronic Flow Meter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .167<br />

Soap Bubble Flow Meter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .167<br />

Generators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .165<br />

Hydrogen Generators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .165<br />

Headspace Accessories and Supplies . . . . . . . . . . . . . . . . . . .142-149<br />

Add-On Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .143<br />

Headspce Add-On Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .143<br />

Headspace Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .144-147<br />

Extended Heated Transfer Line . . . . . . . . . . . . . . . . . . . . . . . . . .144<br />

Heated Transfer Line . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .144<br />

Remote Control Software (RCS) . . . . . . . . . . . . . . . . . . . . . . . . .145<br />

Sample Trays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .145<br />

Tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .145<br />

TurboMatrix and HS 40XL<br />

Adapter Kits for Non-PerkinElmer<br />

Gas Chromatographs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .146<br />

TurboMatrix Headspace/HS 40/<br />

HS 40XL Replacement Parts<br />

and Needle Identification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .147<br />

TurboMatrix Upgrade Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . .147<br />

Headspace Vials, Caps, and Septa . . . . . . . . . . . . . . . . . . . . . .148-149<br />

Headspace Caps and Septa . . . . . . . . . . . . . . . . . . . . . . . . . . .148<br />

Headspace Septa Recommended Temperature Chart . . . . . . . . .148<br />

Headspace Vials . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .148<br />

Vial Crimping Tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .149<br />

Injector Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .157-162<br />

Injector Liners . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .157-158<br />

Glass Inlet Liners . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .157<br />

Injector Septa . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .159<br />

Merlin MicroSeal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .159<br />

Septa for Use with All Injectors . . . . . . . . . . . . . . . . . . . . . . . . .159<br />

Subambient Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .160<br />

AutoSystem<br />

Subambient Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .160<br />

Subambient Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .160<br />

Syringes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .161-162<br />

Autosampler Syringes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .161<br />

Needle Syringes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .161<br />

Syringes – Gas Tight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .162<br />

Ultramicro Volume Syringes . . . . . . . . . . . . . . . . . . . . . . . . . . . .162<br />

Injectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .150-156<br />

Capillary Injectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .150-151<br />

Injector Replacement Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . .150<br />

Miscellaneous Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . .150<br />

Split/Splitless Injector Add-On Kits . . . . . . . . . . . . . . . . . . . . . . .151<br />

POC Injector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .154<br />

POC Replacement Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .154<br />

Programmed-Temperature<br />

On-Column Injector System . . . . . . . . . . . . . . . . . . . . . . . . . . . .154<br />

PSS Injector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .155<br />

Programmed-Temperature<br />

Split/Splitless Injector System . . . . . . . . . . . . . . . . . . . . . . . . . .155<br />

PSS Replacement Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .155<br />

Packed Column Injectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . .152-153<br />

Add-On Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .152<br />

Injector Replacement Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . .152<br />

Miscellaneous Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . .153<br />

Wide-Bore Adapter Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .153<br />

PreVent . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .156<br />

PreVent . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .156<br />

Inlet Liners . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .157<br />

Glass Inlet Liners . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .157<br />

Capillary Split/Splitless Liners . . . . . . . . . . . . . . . . . . . . . . . . . .157<br />

PSS Liners . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .158<br />

Packed Column Liners . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .158<br />

Laboratory Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .163-172<br />

Gas Sampling Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .163-165<br />

Filters and Traps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .163<br />

Gas Purification Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .164<br />

High Purity Brass Regulators . . . . . . . . . . . . . . . . . . . . . . . . . . .165<br />

PG-H2 Pure Gas Hydrogen Generators . . . . . . . . . . . . . . . . . . . .165<br />

Instrument Pneumatics Accessories . . . . . . . . . . . . . . . . . . . . . . . . .166<br />

Manual Pneumatics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .166<br />

PPC Frits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .166<br />

Maintenance Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .167<br />

Flow Meters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .167<br />

Tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .167<br />

Tubing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .167<br />

Valve Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .170-171<br />

Adapters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .170<br />

Air Actuators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .170<br />

Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .171<br />

Valve Fittings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .172<br />

Gas Sampling Valve Fittings . . . . . . . . . . . . . . . . . . . . . . . . . . . .172<br />

Valves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .168<br />

Valves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .168<br />

Valves/Loops . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .169<br />

Sample Loops . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .169<br />

Sample Loops . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .169<br />

Septa . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .159<br />

Injector Septa . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .159<br />

Low Bleed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .159<br />

Merlin MicroSeal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .159<br />

PTFE-Silicone . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .159<br />

Thermogreen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .159<br />

Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .173-178<br />

TotalChrom Data Handling Systems . . . . . . . . . . . . . . . . . . . . . . . . .173<br />

Intelligent Interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .174-175<br />

dotLINK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .174<br />

Integral Link . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .174<br />

NCI Intelligent Interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .174<br />

Power Cords 240 V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .175<br />

Alphabetical Gas Chromatography Index<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

433


Gas Chromatography Index<br />

Alphabetical<br />

Gas Chromatography Index Alphabetical<br />

SoftLINK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .175<br />

Interface Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .176<br />

Interface Personality Modules (IPM) . . . . . . . . . . . . . . . . . . . . . .176<br />

Interface Validation Modules (IVM) . . . . . . . . . . . . . . . . . . . . . . .176<br />

Serial Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .177<br />

IEEE Cables – All TC Versions . . . . . . . . . . . . . . . . . . . . . . . . . .177<br />

TotalChrom TM WS and C/S Serial Cables<br />

to Lantronix Terminal Server . . . . . . . . . . . . . . . . . . . . . . . . . . .177<br />

TotalChrom WS and C/S Serial Cables to PC . . . . . . . . . . . . . . .177<br />

Serial Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .177<br />

Software Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .178<br />

Serial Communications CArds for TurboChrom . . . . . . . . . . . . . .178<br />

TotalChrom Workstation Manuals . . . . . . . . . . . . . . . . . . . . . . . .178<br />

TotalChrom Workstation SI/DI Upgrade Kits . . . . . . . . . . . . . . . . .178<br />

TotalChrom Workstation Software . . . . . . . . . . . . . . . . . . . . . . . .178<br />

Syringes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .161-162<br />

Autosampler Syringes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .161<br />

Needle Syringes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .161-162<br />

Fixed Needle Syringes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .161<br />

Gas Tight Syringes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .162<br />

Removable Needle Syringes . . . . . . . . . . . . . . . . . . . . . . . . . . .161<br />

Ultramicro Volume Syringes . . . . . . . . . . . . . . . . . . . . . . . . . . . .162<br />

Thermal Desorbers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .179-184<br />

Ozone Precursor Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .180<br />

Air Toxics Columns . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .180<br />

Model STS 25 Sequential Tube Sampler . . . . . . . . . . . . . . . . . . .180<br />

Model STS 25 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . .180<br />

Ozone Precursor Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . .180<br />

Sample Tubes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .181<br />

Caps for TurboMatrix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .181<br />

Repalcement Parts for ATD 400 Tube Seal and Tube . . . . . . . . . .181<br />

Sample Tubes for TurboMatrix . . . . . . . . . . . . . . . . . . . . . . . . . .181<br />

Thermal Desorber Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . .182-184<br />

Cold Traps, Fittings, and Accessories . . . . . . . . . . . . . . . . . . . . .182<br />

Consumables Starter Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .182<br />

Gauze Loading Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .182<br />

Interface Cables for ATD 400 . . . . . . . . . . . . . . . . . . . . . . . . . . .182<br />

Interface Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .182-183<br />

Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .183<br />

Miscellaneous Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . .183<br />

Mobile Seal Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .183<br />

Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .183<br />

Trap Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .183-184<br />

TurboMatrix Upgrade Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . .184<br />

TurboMatrix Upper Seal Assembly . . . . . . . . . . . . . . . . . . . . . . .184<br />

Valves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .170-172<br />

Valve Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .170-172<br />

Adapters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .170<br />

Air Acuators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .170<br />

Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .171<br />

Standoffs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .171<br />

Valve Fittings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .172<br />

Vials . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .88-90, 148-149<br />

Autosampler Vials . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .88-89<br />

Autosampler Starter Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .88<br />

Crimp Top Sample Vials and Caps . . . . . . . . . . . . . . . . . . . . . . . .89<br />

Screw Top Sample Vials and Caps . . . . . . . . . . . . . . . . . . . . . . . .89<br />

Crimping Tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .90, 149<br />

11 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .90<br />

20 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .149<br />

Headspace Vials . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .148<br />

Crimp Caps and Septa . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .148<br />

Safety Sample Vials . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .148<br />

434


Inductively Coupled Plasma – MS Index<br />

Alphabetical<br />

Autosampler Supplies and Accessories . . . . . . . . . . . . . . . . .8-10, 188<br />

Autosampler Flame/FIAS Probes . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9<br />

Autosampler Flame/FIAS Trays and Vessels . . . . . . . . . . . . . . . . . . . . .8<br />

Dilution System Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10<br />

Gilson 222 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .188<br />

UltraClean Sampling Probes and Accessories . . . . . . . . . . . . . . . . . .188<br />

Chillers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .189<br />

Chromera Speciation Software . . . . . . . . . . . . . . . . . . . . . . . . . . . .207<br />

Cones . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .189<br />

Nickel Sampler and Skimmer Cones . . . . . . . . . . . . . . . . . . . . . . . . .189<br />

Platinum Sampler and Skimmer Cones . . . . . . . . . . . . . . . . . . . . . . .189<br />

Cooling Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .189<br />

Chillers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .189<br />

Heat Exchanger Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .189<br />

Detectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .190<br />

ELAN Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .206<br />

Flow Injection Sampling Supplies . . . . . . . . . . . . . . . . . . . .21-28, 188<br />

FIAS and FIMS Parts and Supplies . . . . . . . . . . . . . . . . . . . . . . . .22-23<br />

FIAS and FIMS Tubing Adapters and Connectors . . . . . . . . . . . . . . . . .24<br />

FIAS and FIMS Tubing and Supplies . . . . . . . . . . . . . . . . . . . . . . . . . .25<br />

FIAS-400MS Supplies and Accessories . . . . . . . . . . . . . . . . . . . . . .188<br />

Flow Injection Amalgamation System . . . . . . . . . . . . . . . . . . . . . . . . .26<br />

Flow Injection Analysis and Mercury Systems . . . . . . . . . . . . . . . . . . .21<br />

Flow Injection Furnace Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27<br />

Flow Injection Preconcentration Kit and Supplies . . . . . . . . . . . . . . . . .28<br />

Heat Exchanger Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .189<br />

Injector Support Adapters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .195<br />

Injectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .194-195<br />

Alumina Injectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .194<br />

PFA Injector Assemblies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .194<br />

Quartz Injectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .195<br />

Sapphire Injector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .195<br />

Ion Optics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .190<br />

Ion Lenses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .190<br />

ShadowStops . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .190<br />

Mass Flow Controllers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .191<br />

Mass Spectrometer Hardware . . . . . . . . . . . . . . . . . . . . . . . . .189-192<br />

Cones and Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .189<br />

Nickel Sampler and Skimmer Cones . . . . . . . . . . . . . . . . . . . . .189<br />

Platinum Sampler and Skimmer Cones . . . . . . . . . . . . . . . . . . .189<br />

Cooling Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .189<br />

Chillers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .189<br />

Heat Exchangers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .189<br />

Detectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .190<br />

Ion Optics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .190<br />

Ion Lenses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .190<br />

ShadowStops . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .190<br />

Mass Flow Controllers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .191<br />

Reaction Gas Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .192<br />

DRC Gas Cabinets and Upgrade Kits . . . . . . . . . . . . . . . . . . . . .192<br />

Second Reaction Gas Pneumatics . . . . . . . . . . . . . . . . . . . . . . .192<br />

Vacuum Pumps and Accessories . . . . . . . . . . . . . . . . . . . . . . . .192<br />

Nebulizers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .196-199<br />

Concentric Nebulizers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .196-197<br />

MEINHARD Nebulizers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .196<br />

MicroMist Nebulizers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .197<br />

SeaSpray Nebulizers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .197<br />

Teflon PFA Nebulizers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .196<br />

GemClean Cross-Flow II Nebulizer . . . . . . . . . . . . . . . . . . . . . . . . . .197<br />

Microconcentric Nebulizers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .198<br />

Ultrasonic Nebulizers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .199<br />

Peristaltic Pump Tubing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .199<br />

Reaction Gas Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .192<br />

DRC Gas Cabinets and Upgrade Kits . . . . . . . . . . . . . . . . . . . . . . . .192<br />

Second Reaction Gas Pneumatics . . . . . . . . . . . . . . . . . . . . . . . . . .192<br />

Vacuum Pumps and Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . .192<br />

Sample Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .193-205<br />

Consumables Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .193<br />

Graphite Furnace Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .193<br />

HGA – 600MS Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .193<br />

Injector Support Adapters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .195<br />

Injectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .194-195<br />

Alumina Injectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .194<br />

PFA Injector Assemblies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .194<br />

Quartz Injectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .195<br />

Sapphire Injector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .195<br />

Nebulizers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .196-199<br />

Concentric Nebulizers . . . . . . . . . . . . . . . . . . . . . . . . . . . .196-197<br />

GemClean Cross-Flow II Nebulizer . . . . . . . . . . . . . . . . . . . . . . .197<br />

GemClean Cross-Flow II Nebulizer Replacement Parts . . . . . . . . .198<br />

Microconcentric Nebulizers . . . . . . . . . . . . . . . . . . . . . . . . . . . .198<br />

Ultrasonic Nebulizers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .199<br />

Peristaltic Pump Supplies and Accessories . . . . . . . . . . . . . . . . . . . .199<br />

Gilson Peristaltic Pump and Accessories . . . . . . . . . . . . . . . . . .199<br />

Peristaltic Pump Tubing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .199<br />

Sample Introduction Systems and Replacement Parts . . . . . . . .200-201<br />

Organic Sampling Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . .200<br />

Replacement Parts for Twist Type Torch Models . . . . . . . . . . . . .201<br />

Sample Introduction Systems . . . . . . . . . . . . . . . . . . . . . . . . . . .200<br />

Spray Chambers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .202-204<br />

Baffled Cyclonic Spray Chambers . . . . . . . . . . . . . . . . . . . . . . .202<br />

Cyclonic Spray Chamber . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .203<br />

Drain Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .204<br />

PFA Teflon Spray Chamber . . . . . . . . . . . . . . . . . . . . . . . . . . . .204<br />

Scott Spray Chamber . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .204<br />

Torches and Torch Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . .205<br />

RF Coils . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .205<br />

Torches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .205<br />

Sample Introduction Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . .200<br />

HF-Resistant Sample Introduction System . . . . . . . . . . . . . . . . . . . . .200<br />

Organic Sample Introduction Systems . . . . . . . . . . . . . . . . . . . . . . .200<br />

Heavy Organic Sample Introduction System . . . . . . . . . . . . . . . .200<br />

Peltier Cooled Organic Sample Introduction System . . . . . . . . . .200<br />

PFA Teflon Sample Introduction Systems . . . . . . . . . . . . . . . . . . . . .200<br />

Sample Preparation Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . .53-64<br />

Multiwave 3000 Accessories and Supplies . . . . . . . . . . . . . . . . . .56-64<br />

Multiwave Accessories and Supplies . . . . . . . . . . . . . . . . . . . . . . .53-55<br />

Software for ICP-MS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .206<br />

ICP-MS Operating System and Application Software . . . . . . . . . . . . .206<br />

ELAN Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .206<br />

Alphabetical Inductively Coupled Plasma – MS Index<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

435


Inductively Coupled Plasma – MS Index<br />

Alphabetical<br />

Speciation by Chromatography . . . . . . . . . . . . . . . . . . . . . . . .207-208<br />

Speciation Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .207-208<br />

Chromera Speciation Software . . . . . . . . . . . . . . . . . . . . . . . . . .207<br />

HPLC Columns for Speciation . . . . . . . . . . . . . . . . . . . . . . . . . .207<br />

Speciation Accessories and Supplies . . . . . . . . . . . . . . . . . . . . .208<br />

Speciation Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .208<br />

Spray Chambers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .202-204<br />

Baffled Cyclonic Spray Chambers . . . . . . . . . . . . . . . . . . . . . . . . . . .202<br />

Cyclonic Spray Chamber . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .203<br />

PFA Teflon Spray Chamber . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .204<br />

Scott Spray Chamber . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .204<br />

Inductively Coupled Plasma – MS Index Alphabetical<br />

Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .209-212<br />

PerkinElmer Pure Plus Standards for ICP-MS . . . . . . . . . . . . . .209-212<br />

Detection Limit Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . .210<br />

Instrument Calibration Standards . . . . . . . . . . . . . . . . . . . . . . . .210<br />

Multi-Element Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .211<br />

Performance Verification Standards . . . . . . . . . . . . . . . . . . . . . .212<br />

Smart Tune Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .212<br />

Wash Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .212<br />

Torches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .205<br />

Cassette Torch Mount . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .205<br />

Demountable Quartz Torch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .205<br />

High Efficiency Demountable Quartz Torch . . . . . . . . . . . . . . . . . . . .205<br />

Vacuum Pump Oil . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .192<br />

436


Inductively Coupled Plasma – OES Index<br />

Alphabetical<br />

Accessories for ICP–OES . . . . . . . . . . . . . . . . . . . . . . . . . . . . .216-217<br />

Laboratory Products . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .216-217<br />

Air and Gas Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .216<br />

Blower and Vent Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . .217<br />

Cooling Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .217<br />

Autosampler Supplies and Accessories . . . . . . . . . . . . . . . . . . . . .8-10<br />

Autosampler Flame/FIAS Probes . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9<br />

Autosampler Flame/FIAS Trays and Vessels . . . . . . . . . . . . . . . . . . . . .8<br />

Dilution System Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10<br />

Chillers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .217<br />

Cooling Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .217<br />

Chillers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .217<br />

Flow Injection Sampling Supplies . . . . . . . . . . . . . . . . . . . . . . . .21-28<br />

FIAS and FIMS Parts and Supplies . . . . . . . . . . . . . . . . . . . . . . . .22-23<br />

FIAS and FIMS Tubing Adapters and Connectors . . . . . . . . . . . . . . . . .24<br />

FIAS and FIMS Tubing and Supplies . . . . . . . . . . . . . . . . . . . . . . . . . .25<br />

Flow Injection Amalgamation System . . . . . . . . . . . . . . . . . . . . . . . . .26<br />

Flow Injection Analysis and Mercury Systems . . . . . . . . . . . . . . . . . . .21<br />

Flow Injection Furnace Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27<br />

Flow Injection Preconcentration Kit and Supplies . . . . . . . . . . . . . . . . .28<br />

Injector Support Adapters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .220<br />

Injectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .220<br />

Alumina Injectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .220<br />

Quartz Injectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .220<br />

Sapphire Injectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .220<br />

Nebulizers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .221-223<br />

Concentric Nebulizers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .221-222<br />

MEINHARD Nebulizers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .221<br />

MicroMist Nebulizers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .221<br />

PEEK Mira Mist Nebulizer . . . . . . . . . . . . . . . . . . . . . . . . . . . . .222<br />

SeaSpray Nebulizers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .222<br />

GemCone Nebulizers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .222<br />

GemTip Crossflow Nebulizer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .223<br />

Ultrasonic Nebulizer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .221<br />

Peristaltic Pump Tubing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .224<br />

Sample Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .218-230<br />

Accessories for Sample Introduction . . . . . . . . . . . . . . . . . . . . .218-219<br />

Drain Assembly Components . . . . . . . . . . . . . . . . . . . . . . . . . . .218<br />

Protective and Cleaning Accessories . . . . . . . . . . . . . . . . . . . . .218<br />

Purge Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .219<br />

RF Load Coils . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .219<br />

Injectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .220<br />

Alumina Injectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .220<br />

Quartz Injectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .220<br />

Sapphire Injectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .220<br />

Injector Support Adapters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .220<br />

Nebulizers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .221-223<br />

CETAC Ultrasonic Nebulizer . . . . . . . . . . . . . . . . . . . . . . . . . . . .221<br />

Concentric Nebulizers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .221<br />

GemCone Nebulizer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .222<br />

GemTip Crossflow Nebulizer . . . . . . . . . . . . . . . . . . . . . . . . . . .223<br />

Peristaltic Pump Supplies and Accessories . . . . . . . . . . . . . . . . . . . .224<br />

Peristaltic Pump . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .224<br />

Peristaltic Pump Tubing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .224<br />

Spray Chambers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .225-226<br />

Cyclonic Spray Chamber . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .225<br />

Ryton Scott Spray Chamber and Replacement Parts . . . . . . . . . .226<br />

Torches and Torch Accessories . . . . . . . . . . . . . . . . . . . . . . . . .227-230<br />

Torch Bonnets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .227<br />

Torch Modules and Assemblies . . . . . . . . . . . . . . . . . . . . . . . . .227<br />

Torch Replacement Parts . . . . . . . . . . . . . . . . . . . . . . . . . .228-230<br />

Torches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .227<br />

Sample Preparation Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . .50-64<br />

High Pressure Asher System Supplies . . . . . . . . . . . . . . . . . . . . . .50-52<br />

Multiwave 3000 Accessories and Supplies . . . . . . . . . . . . . . . . . .56-64<br />

Multiwave Accessories and Supplies . . . . . . . . . . . . . . . . . . . . . . .53-55<br />

Spray Chambers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .225-226<br />

Baffled Cyclonic Spray Chambers . . . . . . . . . . . . . . . . . . . . . . . . . . .225<br />

Cyclonic Spray Chamber . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .225<br />

Ryton Scott Spray Chamber . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .226<br />

Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .231-236<br />

PerkinElmer Pure Standards for ICP-OES . . . . . . . . . . . . . . . . .231-236<br />

Alternate Trace Metal Drinking Water<br />

and Wastewater Pollution Standards . . . . . . . . . . . . . . . . . . . . .232<br />

Contract Required Detection Limits (CRDL) Standard . . . . . . . . . .232<br />

Drinking Water Pollutant Standards . . . . . . . . . . . . . . . . . . . . . .232<br />

Groundwater and Wastewater Pollution Control Check Standards 233<br />

Instrument Calibration Standards . . . . . . . . . . . . . . . . . . . . . . . .233<br />

Interference Check Standards . . . . . . . . . . . . . . . . . . . . . . . . . .233<br />

Multi-Element Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .234<br />

Quality Control Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . .235<br />

Wavecal Solutions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .236<br />

Torches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .227-228<br />

Demountable Quartz Torch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .227<br />

Quick-Change Torch Modules . . . . . . . . . . . . . . . . . . . . . . . . . .227-228<br />

Alphabetical Inductively Coupled Plasma – OES Index<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

437


Infrared Spectroscopy Index<br />

Alphabetical<br />

Infrared Spectroscopy Index Alphabetical<br />

Autosampler Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .242-244<br />

Desiccant Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .240<br />

Evacuable<br />

Potassium Bromide Die . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .258<br />

Gas Sampling Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .245<br />

Hydraulic Press . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .258<br />

KBr Pellet Mini-press . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .259<br />

KBr Pellet Quick Press . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .259<br />

Laboratory Products . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .240-241<br />

Beamsplitters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .240<br />

Desiccant Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .240<br />

Maintenance Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .240<br />

Source Lamps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .241<br />

Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .241<br />

TG/IR and GC/IR Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .241<br />

Liquid Sampling Cells and Supplies . . . . . . . . . . . . . . . . . . . . .248-251<br />

Demountable Cells and Windows . . . . . . . . . . . . . . . . . . . . . . . . . . .248<br />

FT-NIR Cells and Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .249<br />

FT-NIR Disposable Cells and Holders<br />

for the Spectrum One NTS/100N . . . . . . . . . . . . . . . . . . . . . . . . . . .249<br />

Press-N-Lock Demountable Cell and Windows . . . . . . . . . . . . . . . . .250<br />

Sealed Liquid Cells . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .250<br />

Semi-demountable Cells and Windows . . . . . . . . . . . . . . . . . . . . . . .251<br />

Microscopy Sampling Accessories and Supplies . . . . . . . . . . .252-254<br />

Reflectance Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . .255-256<br />

Diffuse Reflectance Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . .255<br />

FT-NIR Reflectance Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . .256<br />

Horizontal Attenuated Total Reflectance (HATR) Accessories . . . . . . . .255<br />

Specular Reflectance Accessories . . . . . . . . . . . . . . . . . . . . . . . . . .256<br />

Universal Attenuated Total Reflectance (ATR) Accessories . . . . . . . . .256<br />

Sampling Accessories and Supplies . . . . . . . . . . . . . . . . . . . .242-260<br />

Autosampler Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .242-244<br />

Autosampler Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .242<br />

Autosampler Flowcells, Windows, and Supplies . . . . . . . . . . . . .242<br />

Autosampler Sample Cassettes<br />

and Vials for FT-IR and FT-NIR . . . . . . . . . . . . . . . . . . . . . . . . . .242<br />

Autosampler Sample Racks for Spectrum OilExpress . . . . . . . . .243<br />

Autosampler Syringe and Needle Supplies . . . . . . . . . . . . . . . . .243<br />

Autosampler Tubing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .243<br />

Tablet Autosampler Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . .244<br />

Gas Sampling Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .245<br />

Short-path Demountable Gas Cells and Windows . . . . . . . . . . . .245<br />

Liquid Sampling Cells and Supplies . . . . . . . . . . . . . . . . . . . . . .246-251<br />

Crystal Polishing Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .248<br />

Demountable Cells and Windows . . . . . . . . . . . . . . . . . . . . . . . .248<br />

FT-NIR Cells and Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . .249<br />

FT-NIR Disposable Cells and Holders<br />

for the Spectrum One NTS/100N . . . . . . . . . . . . . . . . . . . . . . . .249<br />

Press-N-Lock Demountable Cell and Windows . . . . . . . . . . . . . .250<br />

Sealed Liquid Cells . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .250<br />

Semi-demountable Cells and Windows . . . . . . . . . . . . . . . . . . . .251<br />

Microscopy Sampling Accessories and Supplies . . . . . . . . . . . .252-254<br />

Beam Condensers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .252<br />

Microsampling Tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .253<br />

Rotatable Cell Holder and Microscope Supplies . . . . . . . . . . . . .253<br />

Sampling Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .254<br />

Reflectance Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .255-256<br />

Diffuse Reflectance Accessories . . . . . . . . . . . . . . . . . . . . . . . . .255<br />

FT-NIR Reflectance Accessories . . . . . . . . . . . . . . . . . . . . . . . . .256<br />

Horizontal Attenuated Total Reflectance (HATR) Accessories . . . . .255<br />

Specular Reflectance Accessories . . . . . . . . . . . . . . . . . . . . . . .256<br />

Universal Attenuated Total Reflectance (ATR) Accessories . . . . . .256<br />

Sampling Kits and Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .257<br />

FT-IR Sampling Kit Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . .257<br />

FT-IR Sampling Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .257<br />

Sipper Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .244<br />

Sipper Cells and Windows for the Spectrum One/100 . . . . . . . . .244<br />

Sipper Cells and Windows for the Spectrum One NTS/100N . . . .244<br />

Sipper Pump Tubing and Supplies . . . . . . . . . . . . . . . . . . . . . . .244<br />

Solid Sampling Accessories and Supplies . . . . . . . . . . . . . . . . .258-260<br />

Evacuable Potassium Bromide Die . . . . . . . . . . . . . . . . . . . . . . .258<br />

Hydraulic Press . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .258<br />

KBr Pellet Mini-press . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .259<br />

KBr Pellet Quick Press . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .259<br />

Polarizers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .259<br />

Remote Sampling System Accessories . . . . . . . . . . . . . . . . . . . .260<br />

Sample Holders and Film Mounts . . . . . . . . . . . . . . . . . . . . . . . .260<br />

Sipper Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .244<br />

Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .261-264<br />

Spectrum Infrared Software . . . . . . . . . . . . . . . . . . . . . . . . . . .261-264<br />

Application Software Packages . . . . . . . . . . . . . . . . . . . . . . . . .261<br />

AutoIMAGE Upgrades . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .262<br />

Spectrum One Enhanced Security Software Upgrades . . . . . . . . .264<br />

Spectrum One Software Upgrades . . . . . . . . . . . . . . . . . . . . . . .263<br />

Spectrum One/100 AssureID<br />

Upgrades and Validation Suite . . . . . . . . . . . . . . . . . . . . . . . . . .262<br />

Solid Sampling Accessories and Supplies . . . . . . . . . . . . . . . .258-260<br />

Hydraulic Press and Evacuable<br />

Potassium Bromide Die . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .258<br />

KBr Pellet Mini-press . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .259<br />

KBr Pellet Quick Press . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .259<br />

Polarizers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .259<br />

Remote Sampling System Accessories . . . . . . . . . . . . . . . . . . . . . . .260<br />

Sample Holders and Film Mounts . . . . . . . . . . . . . . . . . . . . . . . . . . .260<br />

Spectrum One Enhanced<br />

Security Software Upgrades . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .264<br />

Spectrum One Software Upgrades . . . . . . . . . . . . . . . . . . . . . . . . .263<br />

Upgrade Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .265<br />

Detector Upgrades . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .265<br />

Microscope Upgrades . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .265<br />

Spectrum One/100 Upgrades . . . . . . . . . . . . . . . . . . . . . . . . . . . . .265<br />

438


Liquid Chromatography Index<br />

Alphabetical<br />

Autosampler Supplies and Accessories . . . . . . . . . . . . . . . . . .270-273<br />

Autosampler Trays and Plates . . . . . . . . . . . . . . . . . . . . . . . . . . . . .270<br />

Peltier Tray Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .270<br />

Sample Trays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .270<br />

Series 200 Autosampler Microtiter Trays and Plates . . . . . . . . . .270<br />

Autosampler Vial Crimping Tools . . . . . . . . . . . . . . . . . . . . . . . . . . .272<br />

Crimpers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .272<br />

Autosampler Vials and Caps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .271<br />

0.2 mL Micro Vials,<br />

Caps, and Septa . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .271<br />

2.0 mL Vials, Caps and Septa . . . . . . . . . . . . . . . . . . . . . . . . . .271<br />

6 mL Vials and Caps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .271<br />

Compatibility Table for Vials and Caps in Sample Trays . . . . . . . .271<br />

ISS-200 and Series 200 Autosampler . . . . . . . . . . . . . . . . . . . . . . .273<br />

Autosampler Syringes Series 200 . . . . . . . . . . . . . . . . . . . . . . .273<br />

BCD Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .273<br />

ISS-200 Injector Valve Parts for BSW Valves . . . . . . . . . . . . . . . .273<br />

ISS-200 Sample Trays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .273<br />

ISS-200 Spares . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .273<br />

Manuals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .273<br />

Replacement Parts Series 200 . . . . . . . . . . . . . . . . . . . . . . . . .273<br />

Cartridge Column Applications . . . . . . . . . . . . . . . . . . . . . . . . .276-284<br />

Biotechnology Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .277<br />

Clinical and Environmental Applications . . . . . . . . . . . . . . . . . . . . . .278<br />

Column Application Notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .276<br />

Food Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .279-280<br />

Industrial Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .281<br />

Pharmaceutical Applications . . . . . . . . . . . . . . . . . . . . . . . . . . .282-284<br />

Cartridge Columns . . . . . . . . . . . . . . . . . . . . . . . . . .274-275, 285-293<br />

Brownlee CHOICE Columns for LC/MS . . . . . . . . . . . . . . . . . . . . . . .285<br />

CHOICE Columns . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .285<br />

Columns for LC/MS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .285<br />

Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .285<br />

Brownlee Cartridge Column Selection and Specification Guide . . . . . .275<br />

Brownlee Cartridge Columns . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .274<br />

Brownlee MPLC Columns . . . . . . . . . . . . . . . . . . . . . . . . . . . . .286-287<br />

Ion Exchange . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .286-287<br />

Polar Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .286-287<br />

Reversed Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .286-287<br />

Brownlee Peco Fast LC Columns . . . . . . . . . . . . . . . . . . . . . . .288-289<br />

Normal Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .289<br />

Reversed Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .289<br />

Scavenger Columns . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .289<br />

Brownlee Preparative and VeloSep Columns . . . . . . . . . . . . . . . . . . .290<br />

Brownlee Preparative Columns . . . . . . . . . . . . . . . . . . . . . . . . .290<br />

Brownlee VeloSep Columns . . . . . . . . . . . . . . . . . . . . . . . . . . . .290<br />

Brownlee Validated MPLC Columns . . . . . . . . . . . . . . . . . . . . . . . . .291<br />

Brownlee Validated Columns . . . . . . . . . . . . . . . . . . . . . . . . . . .291<br />

Guard Cartridge Columns and Accessories . . . . . . . . . . . . . . . . . . . .292<br />

NewGuard Columns . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .292<br />

Replacement Seals for MPLC and Prep-10 Holders . . . . . . . . . .292<br />

Standards Solutions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .292<br />

Holders and Accessories for Cartridge Columns . . . . . . . . . . . . . . . .293<br />

MPLC/PecoTM Holders . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .293<br />

Prep-10 Cartridge Holders . . . . . . . . . . . . . . . . . . . . . . . . . . . . .293<br />

Check Valves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .319<br />

Conventional Column Applications . . . . . . . . . . . . . . . . . . . . . .297-307<br />

Biochemical . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .297-298<br />

Dietary Supplements/Plant Extracts . . . . . . . . . . . . . . . . . . . . . . . . .299<br />

Environmental . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .300-303<br />

Food and Flavors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .304<br />

Pharmaceutical . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .305-307<br />

Conventional Columns . . . . . . . . . . . . . . . . . . . . . . .294-296, 308-313<br />

Brownlee Validated Conventional Columns . . . . . . . . . . . . . . . . . . . .312<br />

Brownlee Validated Cyano . . . . . . . . . . . . . . . . . . . . . . . . . . . . .312<br />

Brownlee Validated IBD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .312<br />

Brownlee Validated PFP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .312<br />

Brownlee Validated Phenyl . . . . . . . . . . . . . . . . . . . . . . . . . . . . .312<br />

Brownlee ValidatedTM Carbamate . . . . . . . . . . . . . . . . . . . . . . .312<br />

Brownlee Analytical Conventional Columns . . . . . . . . . . . . . . . . . . . .308<br />

Brownlee Analytical Amino . . . . . . . . . . . . . . . . . . . . . . . . . . . . .308<br />

Brownlee Analytical C18 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .308<br />

Brownlee Analytical C8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .308<br />

Brownlee Analytical Cyano . . . . . . . . . . . . . . . . . . . . . . . . . . . . .308<br />

Brownlee Analytical PAH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .308<br />

Brownlee Analytical Phenyl . . . . . . . . . . . . . . . . . . . . . . . . . . . .308<br />

Brownlee Analytical Silica . . . . . . . . . . . . . . . . . . . . . . . . . . . . .308<br />

Brownlee Aquapore and Bio Conventional Columns . . . . . . . . . . . . . .309<br />

Brownlee Aquapore AX-300 . . . . . . . . . . . . . . . . . . . . . . . . . . . .309<br />

Brownlee Aquapore ODS C18 . . . . . . . . . . . . . . . . . . . . . . . . . .309<br />

Brownlee Aquapore Octyl C8 . . . . . . . . . . . . . . . . . . . . . . . . . . .309<br />

Brownlee Bio C18 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .309<br />

Brownlee Bio C8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .309<br />

Brownlee CHOICE Conventional Columns . . . . . . . . . . . . . . . . . . . . .310<br />

Brownlee CHOICE Basix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .310<br />

Brownlee CHOICE C18 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .310<br />

Brownlee CHOICE Organic Acids . . . . . . . . . . . . . . . . . . . . . . . .310<br />

Brownlee CHOICE Propyl . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .310<br />

Brownlee Spheri-5 and Validated Conventional Columns . . . . . . . . . .311<br />

Brownlee Spheri-5 ® . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .311<br />

Brownlee Validated Aqueous C18 . . . . . . . . . . . . . . . . . . . . . . . .311<br />

Brownlee Validated C1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .311<br />

Brownlee Validated C18 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .311<br />

Brownlee Validated C4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .311<br />

Brownlee Validated C8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .311<br />

Brownlee ValidatedTM Amino . . . . . . . . . . . . . . . . . . . . . . . . . . .311<br />

Conventional Column Applications . . . . . . . . . . . . . . . . . . . . . . . . . .296<br />

Conventional Columns Selection and Specification Guide . . . . . . . . . .295<br />

Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .295<br />

Guard Cartridges and Accessories . . . . . . . . . . . . . . . . . . . . . . . . . .313<br />

Guard Cartridge Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . .313<br />

Guard Cartridges Brownlee Analytical . . . . . . . . . . . . . . . . . . . . .313<br />

Guard Cartridges Brownlee Bio . . . . . . . . . . . . . . . . . . . . . . . . .313<br />

Guard Cartridges Brownlee CHOICE . . . . . . . . . . . . . . . . . . . . . .313<br />

Guard Cartridges Brownlee Validated . . . . . . . . . . . . . . . . . . . . .313<br />

Degassing Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .318<br />

200 Series On-line . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .318<br />

Helium . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .318<br />

System Spares . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .318<br />

Detectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .314-316<br />

Diode Array Detector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .314<br />

LC-135C/235 Detector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .314<br />

Series 200 Diode Array Detector . . . . . . . . . . . . . . . . . . . . . . . .314<br />

Fluorescence and Refractive Index (RI) Detector . . . . . . . . . . . . . . . .315<br />

LC-240 FL Detector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .315<br />

Series 200 Fluorescence Detector . . . . . . . . . . . . . . . . . . . . . . .315<br />

Series 200a RI Detector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .315<br />

UV/Visible Detector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .316<br />

Series 200/785A UV/VIS<br />

Detector Source Lamps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .316<br />

Series 200/785A UV/VIS<br />

Flowcells/Flowcell . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .316<br />

Series 200/785A UV/VIS<br />

Manuals/Maintenance Items . . . . . . . . . . . . . . . . . . . . . . . . . . .316<br />

Alphabetical Liquid Chromatography Index<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

439


Liquid Chromatography Index<br />

Alphabetical<br />

Filters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .327<br />

Filters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .327<br />

Fittings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .323<br />

PEEK Fingertight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .323<br />

Microtiter Trays and Plates . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .270<br />

Mixers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .321<br />

Dynamic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .321<br />

Static . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .321<br />

Serial Cables to PC from<br />

TotalChrom Interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .331<br />

TotalChrom Software Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .332<br />

TotalChrom Optional Software . . . . . . . . . . . . . . . . . . . . . . . . . .332<br />

TotalChrom Workstation<br />

SI/DI Upgrade Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .332<br />

TotalChrom Workstation Manuals . . . . . . . . . . . . . . . . . . . . . . . .332<br />

Standard Solutions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .292<br />

Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .292<br />

Test Mix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .292<br />

Liquid Chromatography Index Alphabetical<br />

Ovens . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .317<br />

LC Column Ovens . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .317<br />

Series 200 Ovens . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .317<br />

Peltier Trays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .270<br />

100 Position . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .270<br />

Double Micrtiter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .270<br />

Peltier Temperature Controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . .270<br />

Pistons . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .319<br />

Piston Seals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .319<br />

Pistons . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .319<br />

Pumps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .318-322<br />

Degassing Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .318<br />

200 Series On-line<br />

Vacuum Degasser Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .318<br />

Degassing Kits - Helium . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .318<br />

Degassing System Spares - Helium . . . . . . . . . . . . . . . . . . . . . .318<br />

Supply Connectors - Helium . . . . . . . . . . . . . . . . . . . . . . . . . . .318<br />

Piston and Piston Accessories . . . . . . . . . . . . . . . . . . . . . . . . .319-320<br />

Check Valves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .319<br />

Piston Seals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .319<br />

Pistons . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .319<br />

Seals, Pistons, and Check Valves . . . . . . . . . . . . . . . . . . . . . . . .320<br />

Pump Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .321<br />

Bio Conversion Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .321<br />

Maintenance Kits and Tools . . . . . . . . . . . . . . . . . . . . . . . . . . . .321<br />

Manuals and Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . .321<br />

Mixers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .321<br />

Pulse Compensators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .321<br />

Series 200 Pump Solvent Upgrade Kits . . . . . . . . . . . . . . . . . . .321<br />

Solvent Filters and Spargers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .322<br />

Solvent Filters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .322<br />

Solvent Spargers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .322<br />

Sample Loops . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .326<br />

Internal Loop . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .326<br />

PEEK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .326<br />

Stainless Steel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .326<br />

Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .329-332<br />

Intelligent Interfaces for TotalChrom . . . . . . . . . . . . . . . . . . . . . . . . .329<br />

NCI Intelligent Interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .329<br />

dotLINK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .329<br />

Interface Modules for TotalChrom . . . . . . . . . . . . . . . . . . . . . . . . . . .330<br />

Interface Personality Modules (IPM) . . . . . . . . . . . . . . . . . . . . . .330<br />

Interface Validation Modules (IVM) . . . . . . . . . . . . . . . . . . . . . . .330<br />

Power Cords – 240 V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .330<br />

Serial Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .331<br />

IEEE Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .331<br />

Serial Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .331<br />

Serial Cables to Lantronix<br />

Terminal Server from<br />

TotalChrom Interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .331<br />

Supplies and Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . .323-327<br />

Fittings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .323<br />

Fittings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .323<br />

Fittings Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .323<br />

PEEK Union . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .323<br />

PEEK One-Piece FingertightTM Fittings . . . . . . . . . . . . . . . . . . .323<br />

Rheodyne Injection Valves . . . . . . . . . . . . . . . . . . . . . . . . . . . .324-325<br />

Rheodyne 7010 Injection Valve . . . . . . . . . . . . . . . . . . . . . . . . .324<br />

Rheodyne 7725 Injection Valve . . . . . . . . . . . . . . . . . . . . . . . . .324<br />

Rheodyne 8125 Low-Dispersion Stainless Steel Injection Valve . .324<br />

Rheodyne 9725 PEEK Injection Valve . . . . . . . . . . . . . . . . . . . . .324<br />

Rheodyne Valves Spare Parts . . . . . . . . . . . . . . . . . . . . . . . . . . .325<br />

Rheodyne Sample Loops . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .326<br />

Internal Loop for Models 7725/9725 . . . . . . . . . . . . . . . . . . . . .326<br />

PEEK Sample Loops for Rheodyne Valves . . . . . . . . . . . . . . . . . .326<br />

Stainless Steel Sample Loops for Rheodyne Valves and Injectors .326<br />

Sample Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .327<br />

Microsyringes (For Manual Injection) . . . . . . . . . . . . . . . . . . . . .327<br />

PEEK Tubing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .327<br />

Solvent and Sample Filtration . . . . . . . . . . . . . . . . . . . . . . . . . .327<br />

Stainless Steel Tubing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .327<br />

Tubing Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .327<br />

Syringes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .272, 327<br />

Autosampler . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .272<br />

Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .327<br />

Tubing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .327<br />

PEEK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .327<br />

Stainless Steel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .327<br />

Valves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .324-325<br />

7010 Injection Valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .324<br />

7725 Injection Valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .324<br />

8125 Injection Valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .324<br />

9725 Injection Valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .324<br />

Spare Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .325<br />

Vials . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .271-272<br />

Autosampler . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .271-272<br />

Crimp Top . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .271<br />

Crimping Tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .272<br />

Micro . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .271<br />

Polyethylene . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .271<br />

Screw Top . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .271<br />

440


Thermal Analysis Index<br />

Alphabetical<br />

Autosampler Supplies and Accessories (DSC) . . . . . . . . . . . . . . . . .345<br />

Hangdown Wire Kits (TGA) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .371<br />

Calibration Reference Materials . . . . . . . . . . . . . . . .350, 353, 366-368<br />

Diamond DMA/TMA Calibration Reference Materials . . . . . . . . . . . . .366<br />

Diamond TG/DTA Calibration Reference Materials . . . . . . . . . . . . . . .367<br />

DSC Calibration Reference Materials . . . . . . . . . . . . . . . . . . . . . . . .350<br />

DTA Calibration Reference Materials . . . . . . . . . . . . . . . . . . . . . . . . .353<br />

TGA Calibration Reference Materials . . . . . . . . . . . . . . . . . . . . . . . .368<br />

Crimpers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .344<br />

DSC Supplies and Accessories . . . . . . . . . . . . . . . . . . . . . . . . .345-352<br />

Autosampler Supplies and Accessories . . . . . . . . . . . . . . . . . . . . . .345<br />

Diamond DSC, PYRIS 1 DSC Autosampler,<br />

and DSC 7 Robotic System Supplies and Accessories . . . . . . . . .345<br />

DSC High Pressure Cells and Accessories . . . . . . . . . . . . . . . . . . . .346<br />

Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .346<br />

DSC High Pressure Cells . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .346<br />

Intracoolers and Subambient Accessories . . . . . . . . . . . . . . . . .347-348<br />

Intracooler Spares . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .347<br />

Intracoolers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .347<br />

Subambient Accessories for<br />

Diamond DSC/PYRIS 1 DSC . . . . . . . . . . . . . . . . . . . . . . . . . . . .347<br />

Subambient Accessories for DSC 7 . . . . . . . . . . . . . . . . . . . . . .348<br />

Subambient Accessories for<br />

PYRIS 6 DSC/DSC 6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .348<br />

Subambient Accessories for Sapphire DSC . . . . . . . . . . . . . . . . .348<br />

Photocalorimeter Accessories and Supplies . . . . . . . . . . . . . . . . . . .349<br />

Aluminum Capsules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .349<br />

Photocalorimeter Accessory<br />

Kit for Diamond DSC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .349<br />

Photocalorimeter Accessory<br />

Replacement Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .349<br />

Sample Holder Supplies and Calibration Reference Materials . . .350-351<br />

DSC Calibration Reference Materials . . . . . . . . . . . . . . . . . . . . .350<br />

DSC Flow-Through Cover Kits . . . . . . . . . . . . . . . . . . . . . . . . . .350<br />

Sample Holder Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .351<br />

Structure of Common Polymer Poster . . . . . . . . . . . . . . . . . . . . . . . .352<br />

DSC Sample Pans and Crimpers . . . . . . . . . . . . . . . . . . . . . . .336-344<br />

Autosampler Sample Pan and Covers . . . . . . . . . . . . . . . . . . . . . . . .338<br />

DSC Sample Pan Quick Reference . . . . . . . . . . . . . . . . . . . . . .336-337<br />

Aluminum . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .336<br />

Ceramic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .336<br />

Copper . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .337<br />

Gold . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .337<br />

Graphite . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .337<br />

Platinum . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .337<br />

Silver . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .337<br />

Stainless Steel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .337<br />

Titanium . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .337<br />

Hermetically Sealed Sample Pans (up to 3 bar) . . . . . . . . . . . . . . . . .339<br />

High Pressure Sample Pans (24 to 150 bar) . . . . . . . . . . . . . . . . . . .340<br />

Large Volume Pans (55 to 90 μL) and Photo DSC Sample Pans . . . . .341<br />

Large Volume Sample Pans (55 to 90 μL) . . . . . . . . . . . . . . . . .341<br />

Photo DSC Pans . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .341<br />

Open Sample Pans . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .342-343<br />

Universal Crimpers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .344<br />

Crimpers and Sealers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .344<br />

DTA Supplies and Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . .353<br />

DTA Calibration Reference Materials and Supplies . . . . . . . . . . . . . .353<br />

DTA 7 Only Supplies and Accessories . . . . . . . . . . . . . . . . . . . .353<br />

DTA 7 and DTA 1700 Supplies and Accessories . . . . . . . . . . . . .353<br />

DTA Calibration Reference Materials . . . . . . . . . . . . . . . . . . . . .353<br />

Gas Station . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .355<br />

High Pressure Cells and Accessories (DSC) . . . . . . . . . . . . . . . . . . .346<br />

Intracoolers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .347<br />

Laboratory Products and Accessories . . . . . . . . . . . . . . . . . . .354-355<br />

Purge Gas Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .354-355<br />

Filters and Traps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .354<br />

Flow Meters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .354<br />

Gas Cylinder<br />

Installation Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .354<br />

Gas Regulators and Accessories . . . . . . . . . . . . . . . . . . . . . . . .354<br />

Gas Selector Accessory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .355<br />

Gas Station for Thermal Analysis . . . . . . . . . . . . . . . . . . . . . . . .355<br />

Mechanical Analysis (DMA) . . . . . . . . . . . . . . . . . . . . . . . . . . .356-363<br />

3-Point Bending Measuring Systems . . . . . . . . . . . . . . . . . . . .356-357<br />

Diamond DMA Bending Measuring System . . . . . . . . . . . . . . . . .356<br />

DMA 7/DMA 7e 3-Point Bending System Replacement Parts . . .356<br />

DMA 7/DMA 7e Large Adjustable 3-Point/4-Point Bending Kit . . .356<br />

DMA 7/DMA 7e Measuring Parts for ASTM 5934-96 . . . . . . . . .356<br />

DMA 7/DMA 7e Quartz 3-Point Bending Measuring Systems<br />

and Replacement Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .357<br />

Bending/Dual Cantilever Measuring Systems . . . . . . . . . . . . . . . . . .358<br />

Diamond DMA Bending Measuring System/(Dual Cantilever) . . . .358<br />

DMA 7/DMA 7e Dual Cantilever Measuring System<br />

and Replacement Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .358<br />

Compression/Expansion Measuring Systems . . . . . . . . . . . . . . .359-361<br />

Diamond DMA Measuring System and Parts . . . . . . . . . . . . . . . .359<br />

DMA 7/DMA 7e Cup and Plate Kits . . . . . . . . . . . . . . . . . . . . . .359<br />

DMA 7/DMA 7e Parallel Plates with Tray Kits . . . . . . . . . . . . . . .359<br />

DMA 7/DMA 7e Parallel Plate Measuring System<br />

and Replacement Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .360<br />

DMA 7/DMA 7e Quartz Parallel Plate Measuring Systems<br />

and Replacement Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .361<br />

DMA 7/DMA 7e Sintered Parallel Plate Kits . . . . . . . . . . . . . . . .361<br />

Extension and Shear Analysis Measuring Systems . . . . . . . . . . .362-363<br />

Diamond DMA Extension Measuring System<br />

and Replacement Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .362<br />

DMA 7/DMA 7e Extension Measuring System<br />

and Replacement Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .362<br />

DMA 7/DMA 7e Quartz Extension Measuring System . . . . . . . . .363<br />

DMA 7/DMA 7e Quartz Extension Measuring System<br />

and Replacement Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .363<br />

Shear Measuring System for Diamond DMA . . . . . . . . . . . . . . . .363<br />

Mechanical Analysis (TMA) . . . . . . . . . . . . . . . . . . . . . . . . . . . .364-365<br />

TMA Measuring Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . .364-365<br />

Application Solutions with Multiple Probe Types . . . . . . . . . . . . .364<br />

Bending/Flexure Analysis Kits and Parts . . . . . . . . . . . . . . . . . . .364<br />

Dilatometer Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .364<br />

Extension Analysis Kit and Parts . . . . . . . . . . . . . . . . . . . . . . . . .365<br />

Sample Tubes and Cylinders . . . . . . . . . . . . . . . . . . . . . . . . . . .365<br />

TMA 7 Expansion/Compression/<br />

Penetration Quartz Probes . . . . . . . . . . . . . . . . . . . . . . . . . . . . .365<br />

Mechanical Analysis (TMA/DMA) . . . . . . . . . . . . . . . . . . . . . . . . . . .366<br />

Furnace Accessories, Reference Materials, and Supplies . . . . . . . . . .366<br />

Diamond DMA/TMA Calibration<br />

Reference Materials and Tools . . . . . . . . . . . . . . . . . . . . . . . . . .366<br />

Diamond DMA/TMA Furnace Tubes, Thermocouple,<br />

and Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .366<br />

DMA 7, DMA 7e, and TMA7 Reference Materials . . . . . . . . . . . .366<br />

DMA 7, DMA 7e, and TMA7 Thermocouples, Furnaces,<br />

and Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .366<br />

Alphabetical Thermal Analysis Index<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

441


Thermal Analysis Index<br />

Alphabetical<br />

Photocalorimeter Accessories and Supplies . . . . . . . . . . . . . . . . . .349<br />

Purge Gas Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .354-355<br />

Filters and Traps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .354<br />

Flow Meters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .354<br />

Gas Cylinder Installation Accessories . . . . . . . . . . . . . . . . . . . . . . . .354<br />

Gas Regulators and Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . .355<br />

Gas Station and Gas Selector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .355<br />

Sample Holder Supplies (DSC) . . . . . . . . . . . . . . . . . . . . . . . . .350-351<br />

Sample Pans and Covers (DSC) . . . . . . . . . . . . . . . . . . . . . . . .336-343<br />

Sample Pans and Covers (Diamond TG/DTA) . . . . . . . . . . . . . . . . . .367<br />

Thermal Analysis Index Alphabetical<br />

Sample Pans and Covers (TGA) . . . . . . . . . . . . . . . . . . . . . . . . . . . .372<br />

Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .373-374<br />

Subambient Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . .347-348<br />

TG/DTA Supplies and Accessories . . . . . . . . . . . . . . . . . . . . . . . . . .367<br />

Diamond TG/DTA Supplies and Accessories . . . . . . . . . . . . . . . . . . .367<br />

Calibration Reference Materials . . . . . . . . . . . . . . . . . . . . . . . . .367<br />

Furnace and Furnace Accessories . . . . . . . . . . . . . . . . . . . . . . .367<br />

Hyphenated Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .367<br />

In-Line Filter Trap for Diamond TG/DTA . . . . . . . . . . . . . . . . . . .367<br />

Sample Pans . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .367<br />

TGA Supplies and Accessories . . . . . . . . . . . . . . . . . . . . . . . . .368-372<br />

Calibration Reference Materials . . . . . . . . . . . . . . . . . . . . . . . . . . . .368<br />

Furnace and Furnace Accessories . . . . . . . . . . . . . . . . . . . . . . .369-370<br />

Conversion Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .369<br />

Furnace Accessories and Glassware<br />

for TGA Standard and High-Temperature . . . . . . . . . . . . . . . . . .369<br />

TGA Accessories and Supplies . . . . . . . . . . . . . . . . . . . . . . . . . .370<br />

Hangdown Wires, Sample Pans, and Supplies . . . . . . . . . . . . . .371-372<br />

Hangdown Wire Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .371<br />

Sample Pans, Covers, and Supplies . . . . . . . . . . . . . . . . . . . . . .372<br />

Thermal Analysis Software . . . . . . . . . . . . . . . . . . . . . . . . . . . .373-374<br />

PYRIS Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .373-374<br />

PYRIS Series Advanced Software . . . . . . . . . . . . . . . . . . . . . . . .373<br />

PYRIS Series TMA/DMA<br />

Advanced Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .374<br />

PYRIS Series Thermal<br />

Analysis Manager Software . . . . . . . . . . . . . . . . . . . . . . . . . . . .374<br />

Ultramicrobalance Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .375<br />

Weights, Forceps, Stirrups, and Pans . . . . . . . . . . . . . . . . . . . . . . . .375<br />

AD-6 Ultramicrobalance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .375<br />

442


UV Visible Index<br />

Alphabetical<br />

Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8-9, 380-386<br />

Autosampler Supplies and Accessories for UV . . . . . . . . . . . . . . . . . .8-9<br />

Fiber Optics Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .380<br />

General Purpose Optical Bench Kits<br />

for the LAMBDA 6XX/8XX/9XX . . . . . . . . . . . . . . . . . . . . . . . . . . . . .380<br />

Integrating Sphere Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . .381<br />

Polarizer/Depolarizer Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . .382<br />

Polarizer/Depolarizer Crystals<br />

for the LAMBDA 6XX/8XX/9XX . . . . . . . . . . . . . . . . . . . . . . . . . .382<br />

Polarizer/Depolarizer and Accessories<br />

for the LAMBDA 6XX/8XX/9XX . . . . . . . . . . . . . . . . . . . . . . . . . .382<br />

Sipper Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .382-383<br />

Sipper Cells . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .383<br />

Sipper Tubing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .383<br />

Sippers and Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .382<br />

Specular Reflectance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .384<br />

Absolute Specular Reflectance Accessory . . . . . . . . . . . . . . . . . .384<br />

Accessories for Specular Reflectance . . . . . . . . . . . . . . . . . . . . .384<br />

Thermostatting Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . .385-386<br />

Research Peltier System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .386<br />

Routine Peltier Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .385<br />

Autosampler Supplies<br />

and Accessories for UV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8-9<br />

Calibration Reference Materials . . . . . . . . . . . . . . . . . . . . . . . .395-396<br />

Miscellaneous Calibration Materials . . . . . . . . . . . . . . . . . . . . . . . . .396<br />

Secondary Reference Materials . . . . . . . . . . . . . . . . . . . . . . . . . . . .395<br />

Spectralon Diffuse Color Reference Material . . . . . . . . . . . . . . . . . . .396<br />

Spectralon ® UV/Vis/NIR Diffuse<br />

Reflectance Reference Material . . . . . . . . . . . . . . . . . . . . . . . . . . . .396<br />

Cells . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .387-394<br />

Cell Changers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .387-388<br />

Cell Changers for LAMBDA 1X/2X/3X/4X/Bio . . . . . . . . . . . . . . .387<br />

Cell Changers for LAMBDA 6XX/8XX/9XX . . . . . . . . . . . . . . . . . .388<br />

Cell Holders . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .388-389<br />

Cylindrical Cells – Macro with PTFE Stopper . . . . . . . . . . . . . . . . . . .391<br />

Flow-through Cells . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .391<br />

Lids and Stoppers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .391<br />

Replacement Tubing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .391<br />

Standard Cells for Spectroscopy . . . . . . . . . . . . . . . . . . . . . . . .392-394<br />

Macro with PTFE Lid . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .392<br />

Macro with PTFE Stopper . . . . . . . . . . . . . . . . . . . . . . . . . . . . .392<br />

Micro with PTFE Lid . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .393<br />

Micro with PTFE Stopper . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .393<br />

Semi-micro with PTFE Lid – Black . . . . . . . . . . . . . . . . . . . . . . .393<br />

Semi-micro with PTFE Lid – Clear . . . . . . . . . . . . . . . . . . . . . . .393<br />

Semi-micro with PTFE Stopper – Black . . . . . . . . . . . . . . . . . . .394<br />

Semi-micro with PTFE Stopper – Clear . . . . . . . . . . . . . . . . . . .394<br />

Ultra-micro with PTFE Lid . . . . . . . . . . . . . . . . . . . . . . . . . . . . .394<br />

Ultra-micro with Pipette Tips . . . . . . . . . . . . . . . . . . . . . . . . . . .394<br />

Consumables and Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . .395-397<br />

Calibration Reference Materials . . . . . . . . . . . . . . . . . . . . . . . .395-396<br />

Miscellaneous Calibration Materials . . . . . . . . . . . . . . . . . . . . . .396<br />

Secondary Reference Materials . . . . . . . . . . . . . . . . . . . . . . . . .395<br />

Spectralon Diffuse Color Reference Material . . . . . . . . . . . . . . . .396<br />

Spectralon ® UV/Vis/NIR Diffuse<br />

Reflectance Reference Material . . . . . . . . . . . . . . . . . . . . . . . . .396<br />

Source Lamps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .397<br />

Deuterium and Tungsten Source Lamps . . . . . . . . . . . . . . . . . . .397<br />

Deuterium and Tungsten Source Lamps . . . . . . . . . . . . . . . . . . . . .397<br />

Fiber Optics Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .380<br />

General Purpose Optical Bench Kits<br />

for the LAMBDA 6XX/8XX/9XX . . . . . . . . . . . . . . . . . . . . . . . . . . . . .380<br />

Integrating Sphere Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . .381<br />

Polarimetry Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .399-400<br />

Interference Filters, Replacement<br />

Parts and Source Lamps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .400<br />

Polarimetry Cells . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .399<br />

Polarimetry Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .400<br />

Secondary Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .400<br />

Polarizer/Depolarizer Accessories . . . . . . . . . . . . . . . . . . . . . . . . . .382<br />

Research Peltier System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .386<br />

Routine Peltier Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .385<br />

Sippers and Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . .382-383<br />

Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .398<br />

UV/Vis Application and Operating System Software . . . . . . . . . . . . . .398<br />

Advanced Applications Software . . . . . . . . . . . . . . . . . . . . . . . .398<br />

UV WinLab . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .398<br />

Specular Reflectance Accessories . . . . . . . . . . . . . . . . . . . . . . . . . .384<br />

Standard Cells for Spectroscopy . . . . . . . . . . . . . . . . . . . . . . .392-394<br />

Macro with PTFE Lid . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .392<br />

Macro with PTFE Stopper . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .392<br />

Micro with PTFE Lid . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .393<br />

Micro with PTFE Stopper . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .393<br />

Semi-micro with PTFE Lid – Black . . . . . . . . . . . . . . . . . . . . . . . . . .393<br />

Semi-micro with PTFE Lid – Clear . . . . . . . . . . . . . . . . . . . . . . . . . .393<br />

Semi-micro with PTFE Stopper – Black . . . . . . . . . . . . . . . . . . . . . .394<br />

Semi-micro with PTFE Stopper – Clear . . . . . . . . . . . . . . . . . . . . . . .394<br />

Ultra-micro with PTFE Lid . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .394<br />

Ultra-micro with Pipette Tips . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .394<br />

UV WinLab . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .398<br />

Alphabetical UV Visible Index<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

443


Terms and Conditions of Sale<br />

Terms and Conditions of Sale


Terms and Conditions of Sale<br />

1. Delivery Dates and Prices<br />

a) All delivery and shipment dates indicated on the face<br />

hereof are approximate and subject to Seller's availability<br />

schedule. Seller will make reasonable efforts to meet the<br />

delivery date(s) quoted. However, Seller will not be liable<br />

for its failure to meet the quoted delivery dates or for any<br />

delay in performance hereunder due to unforeseen<br />

circumstances or shortages, due to causes beyond its<br />

control, or due to its voluntary or mandatory compliance<br />

with any governmental act, regulation, or request. If, by<br />

reason of such circumstances, Seller's <strong>supplies</strong> of the<br />

equipment or service (hereinafter the “Product(s)”) covered<br />

hereby are limited, Seller shall have the right to allocate the<br />

available supply among its customers in such manner as it,<br />

in its sole discretion, determines appropriate.<br />

b) All orders are priced on the basis of an estimated<br />

shipment date within ninety (90) days of the date of order<br />

to the stated destination. Should Buyer request a change in<br />

the estimated shipment date or otherwise cause delay in<br />

delivery beyond ninety (90) days from the date of order or<br />

request that the Products be shipped outside the country of<br />

original delivery, the prices established by this quote shall<br />

no longer apply, and Seller's list prices in effect on the<br />

actual date of shipment shall be used in determining the<br />

price to be paid. Except as provided above, if the price is<br />

stated by reference to a published price list, then the price<br />

shall be the price on the published price list in effect at the<br />

time Seller receives Buyer's purchase order, without regard<br />

to the requested delivery date. However, if any Product is<br />

ordered prior to the effective date of a published price<br />

change and the delivery date is rescheduled, the price in<br />

effect at the time of the initial delivery date shall apply.<br />

c) If Buyer requests shipment to a country other than the<br />

country originally requested, and if Seller elects not to<br />

cancel the order pursuant to Paragraph 12 hereof, Seller's<br />

applicable surcharge for the actual country of delivery shall<br />

be added to the price.<br />

d) Notwithstanding any provision to the contrary herein, all<br />

prices are subject to increase without notice to reflect<br />

changes in: (1) Federal or State laws taxing raw material or<br />

processed materials; (2) applicable laws or regulations<br />

governing working hours or compensation of labor; and/or<br />

(3) freight charges, insurance costs, duty or other factors<br />

affecting costs of shipment.<br />

2. Packing and Loss or Damage in Transit.<br />

Products will be packed for shipment in a manner suitable<br />

to the method of shipment specified by Buyer, or to the<br />

method selected by Seller in the absence of instructions.<br />

Unless otherwise indicated on the face hereof, all sales<br />

hereunder are f.o.b. shipping point, and all risk of loss or<br />

damage to equipment in transit is upon Buyer. Payment will<br />

be made in accordance with Paragraph 5 below.<br />

3. Payment Due For Partial Deliveries.<br />

Seller may, in its sole discretion, deliver any portion of the<br />

Products ordered, regardless of utility to Buyer in the<br />

absence of the undelivered portion, and all such partial<br />

deliveries shall be accepted and paid for in accordance with<br />

the terms of Paragraphs 4 and 5 below. Likewise,<br />

completion of any installation services shall not be a<br />

condition to Buyer's obligation to remit payment. The<br />

making of a partial delivery that, to any extent, is not in<br />

accordance with the contract of sale shall not affect the<br />

Buyer's obligation hereunder to remit payment.<br />

4. Inspection, Acceptance and Return<br />

of Products or Trade-Ins.<br />

Buyer shall inspect the Products immediately upon receipt<br />

and shall, within five (5) business days after receipt, give<br />

written notice to Seller of any claim for shortage or that the<br />

Products do not conform with the terms of the contract of<br />

sale. If Buyer shall fail to give such notice, the Products<br />

shall be deemed accepted and to conform with the terms<br />

of the contract of sale, and Buyer shall be bound to pay for<br />

the Products in accordance with the terms of Paragraph 5<br />

below. Return of Products, defective or otherwise, will not<br />

be accepted by Seller without (i) written notification from<br />

Buyer to Seller within 30 days of receipt of invoice and<br />

(ii) receipt of a return authorization number from Seller.<br />

Products authorized to be returned shall be shipped f.o.b.<br />

destination, freight pre-paid. When return of nonconforming<br />

goods has been accepted by Seller, conforming shipment<br />

may be made in accordance with Paragraph 1 above and<br />

Paragraph 8 below without further liability on Seller's part.<br />

Buyer will be liable for restocking charges in the event<br />

Products are returned to the Seller which are not defective<br />

and are in accordance with these terms. When a trade-in<br />

is authorized by Seller, Buyer shall ship, f.o.b. destination,<br />

freight pre-paid, the material or equipment so authorized<br />

for trade-in, to Seller's specified location.<br />

5. Payment and Credit Terms.<br />

Unless otherwise indicated on the face hereof, Buyer agrees<br />

to remit payment in full to the address provided on the face<br />

of Seller's invoice for all shipments, including shipments of<br />

any portion of the Products ordered, upon receipt of<br />

invoice. This obligation shall not be contingent upon the<br />

completion of any installation services included in the<br />

purchase price. No cash discounts will be granted. Account<br />

balances not paid in accordance with these terms are<br />

subject to the maximum prevailing legal interest rate<br />

calculated from date of delinquency. In the event Seller<br />

finds it necessary to refer an account to an attorney or an<br />

agent for collection of delinquent accounts, Buyer shall pay<br />

all costs of collection including, without limitation,<br />

reasonable attorneys' fees. Buyer agrees that Seller shall<br />

retain a security interest in the Products sold hereunder to<br />

secure any portion of the price not paid on delivery and<br />

will, on request, execute a security agreement in such form<br />

as is required by Seller, which, at Seller's option, may be<br />

filed with appropriate local, state, or other relevant<br />

authorities. Should Buyer become delinquent in the<br />

payment of any sum due hereunder, or if Buyer becomes<br />

insolvent, or if any proceedings are commenced under any<br />

bankruptcy or similar laws for Buyer's reorganization or<br />

other debt adjustment, Seller will not be obligated to<br />

continue performance. Seller reserves the right to change<br />

the credit terms provided herein when, in Seller's opinion,<br />

the financial condition or previous payment record of Buyer<br />

so warrants. If, within thirty (30) days of receipt of written<br />

notice of such change, Buyer fails to agree and comply with<br />

different terms of credit, and/or fails to give adequate<br />

assurance of due performance, Seller may (a) by notice to<br />

Buyer, treat such failure or refusal as a repudiation by<br />

Buyer of the portion of the purchase order not then fully<br />

performed, whereupon Seller may cancel all further<br />

deliveries and any amounts unpaid hereunder shall<br />

immediately become due and payable; or (b) make<br />

shipments under reservation of a demand for advance<br />

payment or payment against tender of documents of title.<br />

Buyer's acceptance of delivery of any Products shall<br />

constitute a representation that Buyer is solvent.<br />

Terms and Conditions of Sale<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

445


Terms and Conditions of Sale<br />

Terms and Conditions of Sale<br />

6. Taxes.<br />

Buyer is responsible for the ultimate payment of all taxes<br />

which may be assessed or levied on or on account of<br />

Products sold hereunder to Buyer, whether termed a gross<br />

receipts tax, use tax, property tax, sales tax or otherwise.<br />

Where Buyer claims that a transaction is not subject to any<br />

such tax, that Buyer is exempt, or that Seller is not required<br />

to collect such tax, Buyer agrees to provide Seller with any<br />

documentation necessary to support such a claim, to allow<br />

Seller to document its decision not to collect such tax(es),<br />

and to indemnify and hold Seller harmless from and against<br />

any and all fines, penalties, interest, taxes, and other<br />

expenses, including, without limitation, reasonable<br />

attorney's fees, incurred by Seller as a result of reliance<br />

upon Buyer's position.<br />

7. Installation and Site Preparation.<br />

Installation services are included in the purchase price of<br />

the Products sold hereunder only if expressly so stated on<br />

the face of Seller's quotation or in Seller's applicable price<br />

list. Installation services for Products transferred outside the<br />

country of original delivery by Buyer's actions may be<br />

subject to additional charges based on the actual installation<br />

site location. For Products requiring installation by Seller's<br />

service personnel, it is the responsibility of Buyer to<br />

prepare the site environmentally and provide the required<br />

services, power, water, drain, air, bottled gases, permits,<br />

licenses, approvals, etc., as well as whatever is required to<br />

uncrate and transport the Product to its appropriate location<br />

for use. Failure to do so, prior to Seller's service personnel<br />

arriving at Buyer's site on the mutually agreed upon<br />

installation date, will result in a service charge by Seller to<br />

cover the lost time of its service personnel. Should Seller be<br />

unable to perform the required installation services within<br />

twelve months of a Product's shipment date as a result of<br />

Buyer's inability to prepare the site as required, Buyer may<br />

be responsible for additional costs associated with required<br />

hardware, software and firmware updates. Because Seller's<br />

service personnel may be required to enter upon Buyer's<br />

premises for the purpose of providing service to the<br />

Products sold hereunder, Buyer hereby undertakes to<br />

maintain its premises in a safe condition and to comply<br />

with all applicable laws, statutes and regulations governing<br />

workplace health and safety, and hereby accepts full<br />

responsibility for any harm or injury to, or liability arising<br />

from work performed by, Seller's personnel while on<br />

Buyer's premises, except to the extent caused solely by the<br />

gross negligence or willful misconduct of Seller's personnel.<br />

Seller's sales and service personnel are not authorized to<br />

enter into any indemnity or hold harmless agreements on<br />

behalf of Seller.<br />

8. Limited Warranty.<br />

a) Warranty.<br />

i) Seller warrants to Buyer that the Products sold to Buyer<br />

are, at the time of shipment to Buyer from Seller, free from<br />

defects in materials and workmanship.<br />

ii) This warranty shall be valid for a period of 90 days from<br />

the date of shipment to Buyer, unless a different period is<br />

specified herein, or in Seller's applicable price list in which<br />

case such specified period shall apply. Notwithstanding<br />

anything to the contrary contained herein, the warranty<br />

period for data processing equipment, including data<br />

storage devices, processors, printers, terminals,<br />

communication interfaces, tape drives and all similar<br />

devices, is in all cases limited to ninety (90) days from<br />

the date of shipment to Buyer.<br />

iii) Except in the case of an authorized distributor of Seller,<br />

authorized in writing by Seller to extend this warranty to<br />

distributor's customers, the warranty herein applies only to<br />

Buyer as the original purchaser from Seller and may not be<br />

assigned, sold or otherwise transferred to any third party.<br />

iv) As Buyer's sole and exclusive remedy under this<br />

warranty, Seller agrees either to repair or replace, at Seller's<br />

sole option, any part or parts of such Products which,<br />

under proper and normal conditions of use, prove(s) to<br />

be defective within the applicable warranty period.<br />

Alternatively, Seller may at any time, in its sole discretion,<br />

elect to discharge its warranty obligation hereunder by<br />

accepting the return of any defective Product pursuant<br />

to the terms set forth herein and refunding the purchase<br />

price paid by Buyer.<br />

b) Exclusions and Limitations.<br />

i) It is recognized that some parts by their nature may not<br />

function for the warranty period applicable to the Product.<br />

Therefore, expressly excluded from the warranty herein are<br />

chromatography columns, filaments, energy sources, lamps,<br />

power amplifier tubes, graphite tubes, sample cell holders,<br />

burner and furnace chambers, nebulizers, and other similar<br />

parts referenced in the Product's applicable operating<br />

manual.<br />

ii) The warranty herein excludes any equipment or<br />

accessories which are identified on applicable price lists,<br />

quotations, special promotional materials, or on the face<br />

hereof, for which this limited warranty may be further<br />

limited. Included within this category are items produced<br />

by third party manufacturers (as to which Seller passes<br />

to Buyer the warranty it has been provided by the<br />

manufacturer) and items which are sold at specially<br />

reduced prices with reduced warranty protection (in some<br />

cases, extended warranty protection may be available at<br />

an increased price).<br />

iii) This warranty does not cover loss, damage, or defects<br />

resulting from: transportation to the Buyer's facility,<br />

improper or inadequate maintenance by Buyer, Buyersupplied<br />

software or interfacing, unauthorized modification<br />

or misuse, operation outside of the environmental<br />

specifications for the Product or improper site preparation<br />

or maintenance.<br />

iv) No warranty is made with respect to used,<br />

reconstructed, refurbished or previously owned Products,<br />

which will be so marked on the face hereof and, unless<br />

otherwise indicated on the face hereof, shall be sold "As Is".<br />

v) The warranty herein applies only to Products within the<br />

country of original delivery. Products transferred outside<br />

the country of original delivery, either by Seller at the<br />

direction of Buyer or by Buyer's actions subsequent to<br />

delivery, may be subject to additional charges prior to<br />

warranty repair or replacement of such Products based on<br />

the actual location of such Products and Seller's warranty<br />

and/or service surcharges for such location(s).<br />

c) Place of Service.<br />

Except when otherwise provided in Seller's current<br />

applicable price list, Seller shall use reasonable efforts to<br />

perform all warranty services hereunder at Buyer's facility,<br />

as soon as reasonably practicable after notification by Buyer<br />

of a possible defect; provided, however, that Seller reserves<br />

the right to require that Buyer return the Product to Seller's<br />

production facility, transportation charges prepaid, when<br />

necessary to provide proper warranty service.<br />

446


Terms and Conditions of Sale<br />

d) Software and Firmware Products.<br />

The sole and exclusive warranty applicable to software<br />

and firmware products provided by Seller for use with a<br />

processor is as follows: Seller warrants that such software<br />

and firmware will conform to Seller's program manuals<br />

current at the time of shipment to Buyer when properly<br />

installed on the processor, provided, however, that Seller<br />

does not warrant that the operation of the processor or<br />

software or firmware will be uninterrupted or error-free.<br />

SELLER MAKES NO OTHER WARRANTIES, WHETHER<br />

EXPRESS OR IMPLIED, WITH RESPECT TO THE<br />

PRODUCTS, INCLUDING, WITHOUT LIMITATION,<br />

THE IMPLIED WARRANTIES OF MERCHANTABILITY<br />

AND FITNESS FOR A PARTICULAR PURPOSE.<br />

9. Exclusive Remedies.<br />

THE REMEDIES PROVIDED HEREIN ARE BUYER'S SOLE<br />

AND EXCLUSIVE REMEDIES. SELLER SHALL NOT BE<br />

LIABLE FOR ANY INDIRECT, SPECIAL, INCIDENTAL,<br />

CONSEQUENTIAL OR PUNITIVE DAMAGES, WHETHER<br />

BASED ON CONTRACT, TORT, STRICT LIABILITY OR<br />

OTHERWISE, ARISING OUT OF THE DESIGN,<br />

MANUFACTURE, SALE, DELIVERY, INSTALLATION,<br />

SERVICE OR USE OF THE PRODUCTS. SELLER NEITHER<br />

ASSUMES NOR AUTHORIZES ANY OTHER PERSON TO<br />

ASSUME FOR IT ANY OTHER LIABILITY IN<br />

CONNECTION WITH THE DESIGN, MANUFACTURE,<br />

SALE, DELIVERY, INSTALLATION, SERVICE OR USE OF<br />

THE PRODUCTS.<br />

10. Patent Indemnity.<br />

Seller agrees to defend, at its own expense, any suit or legal<br />

proceeding which may be brought against Buyer alleging<br />

infringement by Buyer of any patent of the United States, as<br />

a result of Buyer's use of the Product sold hereunder for its<br />

intended purposes, provided that Buyer shall give Seller<br />

prompt written notice of any claim, threat, or institution of<br />

any such suit or legal proceeding, and provided further that<br />

Seller shall then have the sole right to control and conduct<br />

the defense and/or settlement of such claim, threat, suit or<br />

legal proceeding, either in the name of Seller or Buyer or<br />

both, and Buyer shall, at Seller's request and expense,<br />

provide relevant information and reasonable cooperation.<br />

Seller shall pay all final judgments and all costs and<br />

attorney's fees assessed against Buyer in any such suit or<br />

legal proceeding, provided Buyer has complied with the<br />

conditions hereof with respect to prompt notice and<br />

cooperation in connection with such suit or legal<br />

proceeding and given exclusive control thereof to Seller.<br />

Notwithstanding the foregoing, Seller shall not be liable for<br />

any attorney's fees or other legal expenses incurred by<br />

Buyer without the knowledge and prior written consent of<br />

Seller. Seller shall have the right, at its own expense, to<br />

procure for Buyer the right to continue using the Product<br />

claimed to infringe, replace said Product with an equally<br />

satisfactory non-infringing Product, modify said Product so<br />

that it becomes non-infringing, or remove such Product and<br />

refund the purchase price thereof less a reasonable amount<br />

for use, damage or obsolescence.<br />

The foregoing indemnity fully defines Seller's obligation for<br />

patent infringement. Such obligations shall specifically not<br />

apply to:<br />

a) an infringement claim resulting from additions or<br />

changes in or to the Product made by Buyer or any third<br />

party or from use in combination with other equipment;<br />

or<br />

b) an infringement claim which is settled without the<br />

prior written consent of Seller; or<br />

c) an infringement claim which results from compliance<br />

by Seller with specifications furnished by Buyer.<br />

The total amount of Seller's obligation and liability under<br />

this Section shall not exceed the price paid by Buyer to<br />

Seller for the Product held to infringe, and in no event will<br />

Seller be held accountable for consequential damages under<br />

this indemnity, such as loss of business profits or goodwill.<br />

With respect to any infringement claim arising from Product<br />

manufactured in whole or in part to Buyer's specifications<br />

or from use of such Product in conjunction with any other<br />

goods , Buyer will indemnify and hold harmless Seller from<br />

and against all such claims for damages or profits arising<br />

from infringement of patents, designs, copyrights or<br />

trademarks.<br />

11. Modification of Terms.<br />

BUYER'S ACCEPTANCE OF ANY QUOTATION IS<br />

EXPRESSLY SUBJECT TO BUYER'S ASSENT TO EACH<br />

AND ALL OF THE TERMS AND CONDITIONS SET FORTH<br />

IN SELLER'S QUOTATION, AND BUYER'S ASSENT TO<br />

THESE TERMS AND CONDITIONS OF SALE SHALL BE<br />

CONCLUSIVELY PRESUMED FROM BUYER'S<br />

SUBMISSION OF ITS PURCHASE ORDER. NO ADDITION<br />

TO OR MODIFICATION OF SAID TERMS AND<br />

CONDITIONS SHALL BE BINDING UPON SELLER<br />

UNLESS SPECIFICALLY AGREED TO BY SELLER IN<br />

WRITING. IF BUYER'S PURCHASE ORDER OR OTHER<br />

CORRESPONDENCE CONTAINS TERMS OR CONDITIONS<br />

CONTRARY TO OR IN ADDITION TO THE TERMS AND<br />

CONDITIONS CONTAINED HEREIN OR IN SELLER'S<br />

QUOTATION, ACCEPTANCE OF ANY ORDER BY SELLER<br />

SHALL NOT BE CONSTRUED AS ASSENT TO SUCH<br />

CONTRARY OR ADDITIONAL TERMS AND CONDITIONS<br />

OR CONSTITUTE A WAIVER BY SELLER OF ANY OF THE<br />

TERMS AND CONDITIONS CONTAINED HEREIN OR IN<br />

SELLER'S QUOTATION. SELLER'S ACCEPTANCE OF<br />

BUYER'S PURCHASE ORDER IS EXPRESSLY<br />

CONDITIONED ON BUYER'S ASSENT TO THESE TERMS<br />

AND CONDITIONS. NO MODIFICATION OR WAIVER OF<br />

THESE TERMS AND CONDITIONS IS VALID, UNLESS<br />

CONFIRMED IN WRITING BY AN AUTHORIZED<br />

REPRESENTATIVE OF SELLER.<br />

12. Authority to Export.<br />

ALL ORDERS ACCEPTED FOR EXPORT (AND/OR RE-<br />

EXPORT) ARE SUBJECT TO: 1) UNITED STATES<br />

GOVERNMENT EXPORT REGULATIONS; AND 2) BUYER<br />

PROVIDING SELLER WITH ALL DOCUMENTATION<br />

NECESSARY FOR SHIPMENT TO THE DESTINATION<br />

COUNTRY.<br />

13. Software Licenses and Copyrighted Material.<br />

a) Seller provides software products by license only. The<br />

terms of the license are available from Seller and are<br />

deemed accepted by Buyer on delivery of licensed software.<br />

b) Unless otherwise specified, Seller's copyrighted material<br />

(software, firmware, and printed documentation) may not<br />

be copied except for archive purposes, to replace a defective<br />

copy, or for program error verification by Buyer.<br />

Terms and Conditions of Sale<br />

See page 42 for ordering information.<br />

For the most current product listing,<br />

visit www.perkinelmer.com/<strong>supplies</strong><br />

447


Terms and Conditions of Sale<br />

Terms and Conditions of Sale<br />

14. Miscellaneous.<br />

a) Excusable Delays.<br />

Seller shall not be liable for delays in delivery or failure to<br />

manufacture or deliver goods due to acts of God, acts or<br />

failures to act of Buyer, acts of civil military authority, fires,<br />

strikes, floods, epidemics, attack, war, delays in<br />

transportation or other causes beyond Seller's reasonable<br />

control, including, without limitation, delays in obtaining<br />

or inability to obtain necessary labor, materials,<br />

components, or manufacturing facilities.<br />

b) Governing Law.<br />

The contract of sale shall be governed by and construed in<br />

accordance with the laws of the Commonwealth of<br />

Massachusetts, U.S.A. without regard to its principles of<br />

conflict of laws. Any disputes relating to the contract of sale<br />

between Buyer and Seller shall be adjudicated in the state<br />

or federal courts in the Commonwealth of Massachusetts,<br />

U.S.A., and both parties hereby consent to the exclusive<br />

jurisdiction of said courts for purposes of any such<br />

litigation. The parties expressly agree to waive application<br />

of the United Nations Convention on Contracts for the<br />

International Sale of Goods.<br />

c) Confidential Data and Information.<br />

If, in connection with the sale, purchase, use, or<br />

maintenance of the Products, Seller is requested, required,<br />

or deems it advisable to furnish data or information which<br />

it, in its sole discretion, deems proprietary, confidential, or<br />

both, Seller shall not, in any event, submit or be required to<br />

furnish such data or information unless Buyer enters into<br />

an agreement concerning the handling, use, copying,<br />

retention and return of such information, the form of which<br />

agreement is available to Buyer on request. Seller does not<br />

agree to accept any proprietary or confidential information<br />

of Buyer in the absence of such a written agreement signed<br />

by an authorized representative of Seller.<br />

d) Assignment.<br />

Buyer may not assign, transfer or delegate any of its rights<br />

or obligations herein without the prior written consent of<br />

Seller, and any purported assignment of such rights or<br />

obligations without such consent shall be null and void.<br />

e) Severability.<br />

If any provision herein is deemed unenforceable by a court<br />

of competent jurisdiction, the other provisions shall remain<br />

in full force and effect as if the unenforceable provision had<br />

not been included.<br />

448


PerkinElmer and OneSource are registered trademarks of PerkinElmer, Inc. © 2005 PerkinElmer, Inc. 400073A_01<br />

Scientists aren’t the only ones making<br />

breakthrough discoveries.<br />

Procurement and sourcing pros are discovering OneSource ® – PerkinElmer’s<br />

comprehensive solution for maintaining all your lab equipment. Now they have<br />

smart ways to reduce costs and improve service quality. Scientist productivity<br />

rises too, thanks to faster maintenance response and repair times. And, best of all,<br />

the longer they work with OneSource, the greater the savings.<br />

Introducing<br />

To make your own discoveries, call today for your free maintenance audit.<br />

In the U.S. and Canada, call 303-884-9510; in Europe, call +44 (0) 7785 921164.<br />

Or send an e-mail to onesource@perkinelmer.com. See? You’re saving already.<br />

www.perkinelmer.com/onesource


www.perkinelmer.com/<strong>supplies</strong><br />

PerkinElmer Life and<br />

Analytical Sciences<br />

710 Bridgeport Avenue<br />

Shelton, CT 06484-4794 USA<br />

Phone: (800) 762-4000 or<br />

(+1) 203-925-4602<br />

www.perkinelmer.com<br />

For a complete listing of our global offices, visit www.perkinelmer.com/lasoffices<br />

©2005 PerkinElmer, Inc. All rights reserved. PerkinElmer is a trademark of PerkinElmer, Inc.<br />

007386_03 Printed in the USA

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!