V<br />
VD<br />
KL1950<br />
KL1951<br />
Typ / type<br />
Artikel-Nr. / article no.<br />
<strong>FB045</strong>-<strong>4E</strong>A<strong>.4F</strong>.2L<br />
124 689<br />
<strong>FB045</strong>-<strong>4E</strong>K<strong>.4F</strong>.6L<br />
124 180<br />
Leistungsdaten<br />
Performance data<br />
<strong>FB045</strong>-<strong>4E</strong>_<strong>.4F</strong>._L<br />
1~ 230 V ± 10% 50 Hz<br />
160<br />
140<br />
2<br />
U<br />
V<br />
I<br />
A<br />
P 1<br />
W<br />
n<br />
min -1<br />
L WA<br />
dB<br />
Motor 106-50-4<br />
P 1<br />
0,41<br />
I<br />
1,9<br />
n<br />
1320<br />
I A<br />
5,0<br />
C 400V<br />
8<br />
t R 2<br />
70<br />
t R 70<br />
5<br />
kW<br />
A<br />
min -1 A<br />
µF<br />
°C<br />
°C<br />
p d2<br />
1,9 · 10 -6 · V 2<br />
∆pfa<br />
in Pa<br />
120<br />
100<br />
80<br />
60<br />
40<br />
20<br />
0<br />
B045<strong>4E</strong>L1<br />
14<br />
11<br />
0 2.000 4.000 6.000<br />
3<br />
V in m /h<br />
[KL982] B1 E 112 <strong>FB045</strong><strong>4E</strong>K4F6LK801<br />
8<br />
5<br />
15 12<br />
9<br />
6<br />
3<br />
2<br />
3<br />
5<br />
6<br />
8<br />
9<br />
11<br />
12<br />
14<br />
15<br />
230<br />
230<br />
160<br />
130<br />
105<br />
1,9<br />
1,45<br />
1,55<br />
1,3<br />
1,7<br />
1,25<br />
1,8<br />
1,35<br />
1,8<br />
1,45<br />
410<br />
300<br />
330<br />
260<br />
260<br />
190<br />
220<br />
170<br />
175<br />
145<br />
1320<br />
1400<br />
1380<br />
1410<br />
1240<br />
1340<br />
1080<br />
1250<br />
810<br />
1060<br />
74<br />
72<br />
72<br />
69<br />
71<br />
66<br />
69<br />
58<br />
66<br />
2<br />
5 / 8<br />
gemessen in Volldüse ohne Berührungsschutzgitter in Einbauart A nach DIN 24163 Teil 2 (ISO 5801)<br />
measured in full bell mouth without guard grille in installation type A according to DIN 24163 Part 2 (ISO 5801)<br />
gemessen in Kurzdüse mit druckseitigem Berührungsschutzgitter<br />
measured in short bell mouth with guard grille on the pressure side<br />
74 A01 Axialventilatoren / Axial fans
Axialventilator<br />
Axial fan<br />
<strong>FB045</strong>-<strong>4E</strong>_<strong>.4F</strong>._L<br />
f = 50 Hz, < ) 25 °<br />
Beschreibung<br />
Description<br />
Maßblatt<br />
Dimension sheet<br />
<strong>FB045</strong>-<strong>4E</strong>A<strong>.4F</strong>.2L<br />
Artikel-Nr. / article no.<br />
124 689<br />
Axialventilator Bauform A<br />
Klemmenkasten<br />
Luftförderrichtung V (2)<br />
Axial fan design A<br />
Terminal box<br />
Air flow direction V (2)<br />
7,7 kg<br />
Anschlußschaltbild 104XA<br />
Connection diagram<br />
<strong>FB045</strong>-<strong>4E</strong>K<strong>.4F</strong>.6L<br />
Artikel-Nr. / article no.<br />
124 180<br />
Axialventilator für Einbau in Kurzdüse<br />
Motoraufhängung mit druckseitig integriertem<br />
Berührungsschutz und Klemmenkasten<br />
Luftförderrichtung VD (6)<br />
Axial fan for installation in short bell mouth<br />
Motor suspension with on pressure side<br />
integrated guard grille and terminal box<br />
Air flow direction VD (6)<br />
9,5 kg Anschlußschaltbild 104XA<br />
Connection diagram<br />
A01 Axialventilatoren / Axial fans<br />
75
Axialventilator<br />
Axial fan<br />
<strong>FB045</strong>-<strong>4E</strong>_<strong>.4F</strong>._P<br />
f = 50 Hz, < ) 30 °<br />
Bauformen<br />
Designs<br />
V<br />
VD<br />
Typ / type<br />
Artikel-Nr. / article no.<br />
KL1950<br />
<strong>FB045</strong>-<strong>4E</strong>A<strong>.4F</strong>.2P<br />
107 179<br />
KL1951<br />
<strong>FB045</strong>-<strong>4E</strong>K<strong>.4F</strong>.6P<br />
209 023<br />
Leistungsdaten<br />
Performance data<br />
<strong>FB045</strong>-<strong>4E</strong>_<strong>.4F</strong>._P<br />
1~ 230 V ± 10% 50 Hz<br />
Motor 106-50-4<br />
P 1<br />
0,48<br />
I<br />
2,1<br />
n<br />
1325<br />
I A<br />
5,1<br />
C 400V<br />
8<br />
t R 2<br />
70<br />
t R 70<br />
5<br />
kW<br />
A<br />
min -1 A<br />
µF<br />
°C<br />
°C<br />
p d2<br />
1,9 · 10 -7 · V 2<br />
pfa<br />
in Pa<br />
D<br />
140<br />
120<br />
100<br />
80<br />
60<br />
40<br />
20<br />
0<br />
B045<strong>4E</strong>P1<br />
14<br />
11<br />
15<br />
0 2.000 4.000 6.000<br />
3<br />
V in m /h<br />
[KL1018] B1 E091 <strong>FB045</strong><strong>4E</strong>K4F6PK801<br />
8<br />
2<br />
5<br />
12<br />
9<br />
6<br />
3<br />
2<br />
3<br />
5<br />
6<br />
8<br />
9<br />
11<br />
12<br />
14<br />
15<br />
U<br />
V<br />
230<br />
230<br />
160<br />
130<br />
105<br />
I<br />
A<br />
2,1<br />
1,6<br />
1,8<br />
1,5<br />
1,9<br />
1,55<br />
1,95<br />
1,7<br />
1,75<br />
1,65<br />
P 1<br />
W<br />
480<br />
340<br />
390<br />
330<br />
300<br />
240<br />
250<br />
210<br />
170<br />
160<br />
1325<br />
1390<br />
1320<br />
1360<br />
1120<br />
1220<br />
850<br />
1050<br />
690<br />
810<br />
L WA<br />
n<br />
min -1 dB<br />
77<br />
73<br />
73<br />
70<br />
70<br />
64<br />
66<br />
57<br />
60<br />
2<br />
5 / 8<br />
gemessen in Volldüse ohne Berührungsschutzgitter in Einbauart A nach DIN 24163 Teil 2 (ISO 5801)<br />
measured in full bell mouth without guard grille in installation type A according to DIN 24163 Part 2 (ISO 5801)<br />
gemessen in Kurzdüse mit druckseitigem Berührungsschutzgitter<br />
measured in short bell mouth with guard grille on the pressure side<br />
76 A01 Axialventilatoren / Axial fans
Axialventilator<br />
Axial fan<br />
<strong>FB045</strong>-<strong>4E</strong>_<strong>.4F</strong>._P<br />
f = 50 Hz, < ) 30 °<br />
Beschreibung<br />
Description<br />
Maßblatt<br />
Dimension sheet<br />
<strong>FB045</strong>-<strong>4E</strong>A<strong>.4F</strong>.2P<br />
Artikel-Nr. / article no.<br />
107 179<br />
Axialventilator Bauform A<br />
Klemmenkasten<br />
Luftförderrichtung V (2)<br />
Axial fan design A<br />
Terminal box<br />
Air flow direction V (2)<br />
7,7 kg<br />
Anschlußschaltbild 104XA<br />
Connection diagram<br />
<strong>FB045</strong>-<strong>4E</strong>K<strong>.4F</strong>.6P<br />
Artikel-Nr. / article no.<br />
209 023<br />
Axialventilator für Einbau in Kurzdüse<br />
Motoraufhängung mit druckseitig integriertem<br />
Berührungsschutz und Klemmenkasten<br />
Luftförderrichtung VD (6)<br />
Axial fan for installation in short bell mouth<br />
Motor suspension with on pressure side<br />
integrated guard grille and terminal box<br />
Air flow direction VD (6)<br />
9,5 kg Anschlußschaltbild 104XA<br />
Connection diagram<br />
A01 Axialventilatoren / Axial fans<br />
77
Axialventilator<br />
Axial fan<br />
<strong>FB045</strong>-<strong>4E</strong>_.4I._S<br />
f = 50 Hz, < ) 35 °<br />
Bauformen<br />
Designs<br />
V<br />
VD<br />
KL1950<br />
KL1951<br />
Typ / type<br />
Artikel-Nr. / article no.<br />
<strong>FB045</strong>-<strong>4E</strong>A.4I.2S<br />
124 690<br />
<strong>FB045</strong>-<strong>4E</strong>K.4I.6S<br />
124 181<br />
Leistungsdaten<br />
Performance data<br />
<strong>FB045</strong>-<strong>4E</strong>_.4I._S<br />
1~ 230 V ± 10% 50 Hz<br />
Motor 106-70-4<br />
P 1<br />
0,57<br />
I<br />
2,4<br />
n<br />
1270<br />
I A<br />
4,2<br />
C 400V<br />
10<br />
t R 2<br />
70<br />
t R 70<br />
5<br />
kW<br />
A<br />
min -1 A<br />
µF<br />
°C<br />
°C<br />
pfa<br />
in Pa<br />
+<br />
140<br />
120<br />
100<br />
80<br />
60<br />
40<br />
20<br />
14<br />
11<br />
2<br />
8<br />
5<br />
2<br />
3<br />
5<br />
6<br />
8<br />
9<br />
11<br />
12<br />
U<br />
V<br />
230<br />
230<br />
160<br />
130<br />
I<br />
A<br />
2,4<br />
2,0<br />
2,1<br />
1,95<br />
2,4<br />
2,2<br />
2,4<br />
2,3<br />
P 1<br />
W<br />
570<br />
440<br />
480<br />
430<br />
370<br />
340<br />
290<br />
280<br />
1270<br />
1350<br />
1330<br />
1360<br />
1110<br />
1170<br />
880<br />
960<br />
L WA<br />
n<br />
min -1 dB<br />
80<br />
77<br />
77<br />
75<br />
73<br />
65<br />
68<br />
p d2<br />
1,75 · 10 -6 · V 2<br />
0<br />
B045<strong>4E</strong>S1<br />
15<br />
0 2.000 4.000 6.000 8.000<br />
3<br />
V in m /h<br />
[KL1021] B1 E107 <strong>FB045</strong><strong>4E</strong>K4I6SK801<br />
12<br />
9<br />
6<br />
3<br />
14<br />
15<br />
105<br />
2,2<br />
2,1<br />
210<br />
200<br />
660<br />
720<br />
57<br />
60<br />
2<br />
5 / 8<br />
gemessen in Volldüse ohne Berührungsschutzgitter in Einbauart A nach DIN 24163 Teil 2 (ISO 5801)<br />
measured in full bell mouth without guard grille in installation type A according to DIN 24163 Part 2 (ISO 5801)<br />
gemessen in Kurzdüse mit druckseitigem Berührungsschutzgitter<br />
measured in short bell mouth with guard grille on the pressure side<br />
78 A01 Axialventilatoren / Axial fans
Axialventilator<br />
Axial fan<br />
<strong>FB045</strong>-<strong>4E</strong>_.4I._S<br />
f = 50 Hz, < ) 35 °<br />
Beschreibung<br />
Description<br />
Maßblatt<br />
Dimension sheet<br />
<strong>FB045</strong>-<strong>4E</strong>A.4I.2S<br />
Artikel-Nr. / article no.<br />
124 690<br />
Axialventilator Bauform A<br />
Klemmenkaten<br />
Luftförderrichtung V (2)<br />
Axial fan design A<br />
Terminal box<br />
Air flow direction V (2)<br />
9,7 kg<br />
Anschlußschaltbild 104XA<br />
Connection diagram<br />
<strong>FB045</strong>-<strong>4E</strong>K.4I.6S<br />
Artikel-Nr. / article no.<br />
124 181<br />
Axialventilator für Einbau in Kurzdüse<br />
Motoraufhängung mit druckseitig integriertem<br />
Berührungsschutz und Klemmenkasten<br />
Luftförderrichtung VD (6)<br />
Axial fan for installation in short bell mouth<br />
Motor suspension with on pressure side<br />
integrated guard grille and terminal box<br />
Air flow direction VD (6)<br />
11,5 kg Anschlußschaltbild 104XA<br />
Connection diagram<br />
A01 Axialventilatoren / Axial fans<br />
79