Infuse Fluids up to 50% Faster with<br />
<strong>Edwards</strong> <strong>Multi</strong>-<strong>Med</strong> <strong>Central</strong> <strong>Venous</strong> <strong>Catheters</strong><br />
OFFERED EXCLUSIVELY THROUGH CENTURION MEDICAL PRODUCTS
When rapid infusion of fluids is a must, <strong>Edwards</strong><br />
Lifesciences meets this need with <strong>Edwards</strong> <strong>Multi</strong>-<strong>Med</strong><br />
central venous catheters.<br />
Designed for Optimal Flow from “Hub to Tip” 1<br />
• Infuses fluids up to 50% faster than standard CVCs<br />
• Backform design enhances fluid flow throughout<br />
catheter<br />
• Optimized lumen design maximizes lumen<br />
dimensions<br />
Double Protection Against Infection<br />
Reduce the risk of catheter-related infection<br />
with <strong>Edwards</strong> AMC THROMBOSHIELD<br />
(an antimicrobial * heparin coating)<br />
• Provides antimicrobial protection on the inside<br />
and outside of the catheter<br />
• Reduces microbial colonization 2 and reduces<br />
thrombus formation<br />
• No other CVC offers this <strong>com</strong>bination of<br />
patient-protection features<br />
Unique One-Handed Guidewire<br />
Insertion Device<br />
The single-handed guidewire helps<br />
you better manage the task at hand<br />
• Simple operation allows focus<br />
on the procedure, not the device<br />
• Ergonomic guidewire insertion<br />
advancer allows easier, one-handed operation<br />
• Centimeter markings assist in determining<br />
insertion depth<br />
• Flexibility of a J-tip or straight tip depending<br />
on your needs<br />
<strong>Multi</strong>-<strong>Med</strong> <strong>Central</strong> <strong>Venous</strong> Cath<br />
Major Competitor’s<br />
CV Catheter<br />
<strong>Edwards</strong> <strong>Multi</strong>-<strong>Med</strong><br />
CV Catheter<br />
Optional Interlink<br />
injection sites help<br />
eliminate<br />
needlestick risks.
Flexible, Kink-Resistant Polyurethane<br />
Catheter material selection based<br />
on your clinical needs<br />
• Polyurethane material contributes<br />
to excellent handling,<br />
flexibility and kink-resistance<br />
• Soft tip on multi-lumen<br />
catheters for enhanced patient <strong>com</strong>fort<br />
and reduced risk of vessel perforation 3<br />
• Clear extension lumens for excellent fluid path<br />
visualization<br />
• Easy-to-read lumen identification and gauge size<br />
on color-coded hubs<br />
Increased Safety with Needleless Access<br />
Available with Interlink needleless injection caps<br />
• The Interlink system minimizes the risk of<br />
needlestick injuries to healthcare workers 4<br />
Use <strong>Edwards</strong> <strong>Multi</strong>-<strong>Med</strong> central venous catheters<br />
in every environment that requires fast infusion<br />
of fluids. The <strong>Multi</strong>-<strong>Med</strong> <strong>Central</strong> <strong>Venous</strong> Catheter<br />
brings you everything you expect from <strong>Edwards</strong>:<br />
faster flow rates, protection against catheter-related<br />
infection, needleless access and easy one-handed<br />
guidewire handling.<br />
eters for Maximum Flow Rates<br />
Microbial Inhibition with<br />
AMC THROMBOSHIELD Coating<br />
7F 2L & 3L Polyurethane <strong>Multi</strong>-<strong>Med</strong> <strong>Catheters</strong><br />
Average Performance<br />
16 cm Long Catheter 20 cm Long Catheter<br />
Catheter Flow Rate Flow Rate Cross-Section<br />
(ml/hr) (ml/hr) Gauge Equivalence<br />
Triple Lumen<br />
Proximal 1670 1420 18<br />
<strong>Med</strong>ial 1500 1300 18<br />
Distal 3510 3160 16<br />
Double Lumen<br />
Proximal 3620 3200 16<br />
Distal 3608 3292 16<br />
Soft tip<br />
enhances<br />
patient <strong>com</strong>fort.
<strong>Multi</strong>-<strong>Med</strong> <strong>Central</strong> <strong>Venous</strong> <strong>Catheters</strong><br />
<strong>Multi</strong>-<strong>Med</strong> central venous catheters are available in two different configurations: basic set and expanded kit.<br />
Contents of the basic set and expanded kit are as follows:<br />
Basic Set<br />
• One radiopaque polyurethane catheter<br />
• One vessel dilator<br />
• One injection cap per lumen<br />
• One optional suture loop with box clamp<br />
• One 0.032" or 0.035" diameter x 60 cm guidewire with<br />
straight and J-tip and guidewire insertion device<br />
• One 5 ml syringe<br />
• One 22 ga x 1-1/2" needle<br />
• One 18 ga x 2-1/2" thin-wall needle<br />
• One 18 ga x 2-1/2" catheter over 20 ga needle<br />
Expanded Kit<br />
Includes contents of Basic Set plus<br />
• One CSR wrap<br />
• One fenestrated drape<br />
• One 5 ml ampule lidocaine HCI 1%<br />
• One 3 ml syringe<br />
• One 25 ga x 1" needle<br />
• Additional 5 ml syringe<br />
• One 3-0 suture with straight cutting needle<br />
• One disposable scalpel with #11 blade<br />
• One packet Povidone Iodine triple prep swabs<br />
• One packet Povidone Iodine ointment<br />
• Two 2" x 2" gauze pads<br />
• Five 4" x 4" gauze pads<br />
• One 3 ml applicator with ChloraPrep preoperative<br />
skin preparation (optional)<br />
<strong>Edwards</strong> Lifesciences LLC offers other<br />
members of the access family,<br />
including introducers and central venous catheters,<br />
as well as a full line of <strong>Edwards</strong> Swan-Ganz <strong>Catheters</strong>,<br />
disposable pressure transducers and<br />
a blood management protection system.<br />
*Contact inhibition of microbial growth on surface of catheters. Effective against<br />
organisms <strong>com</strong>monly associated with noso<strong>com</strong>ial infection, e.g., S. epidermidis.<br />
REFERENCES<br />
1. LIchtenthal P. Maximum Flow Rates through Triple Lumen <strong>Central</strong> <strong>Venous</strong> <strong>Catheters</strong>–<br />
Who has the highest flow? Presented October 17, 1997. American Society of Critical<br />
Care Anesthesiologists. Abstract.<br />
2. Tebbs SE, Elliot TS. A Novel Antimicrobial <strong>Central</strong> <strong>Venous</strong> Catheter Impregnated with<br />
Benzalkonium Chloride. Journal of Antimicrobial Chemotherapy. 1993;31:261-271.<br />
3. Gravenstien N, Blackshear RH. In Vitro Evaluation of Relative Performance of<br />
<strong>Central</strong> <strong>Venous</strong> <strong>Catheters</strong>: Comparison of Materials, Selected Models, Number of<br />
Lumens, and Angles of Incidence to Simulate Membrane. J Clin Monit. 7:1-6:1991.<br />
4. Skolnick R. et al. Evaluation and Implementation of a Needleless Intravenous<br />
System: Making Needlesticks a Needless Problem. AJIC. Feb 1993: 21, 39-41.<br />
Significant antimicrobial activity associated with AMC THROMBOSHIELD has been<br />
demonstrated using in vitro agar diffusion assays against the following organisms:<br />
Staphylococcus epidermidis, Staphylococcus aureus, Streptococcus faecalis, Candida<br />
albicans, Escherichia coli, Serratia marcescens, and Acinetobacter calcoaceticus.<br />
Rx only. See instructions for use for full prescribing information.<br />
<strong>Edwards</strong> and the stylized E logo are trademarks of <strong>Edwards</strong> Lifesciences Corporation.<br />
<strong>Edwards</strong> Lifesciences, AMC Thromboshield and <strong>Multi</strong>-<strong>Med</strong> are trademarks of <strong>Edwards</strong><br />
Lifesciences Corporation and are registered in the United States Patent and<br />
Trademark Office.<br />
ChloraPrep is a trademark of CareFusion or one of its subsidiaries.<br />
All rights reserved. AR01219<br />
Offered exclusively through:<br />
100 CENTURION WAY | P.O. BOX 510 | WILLIAMSTON | MICHIGAN | 48895<br />
517.546.5400 | 800.248.4058 | fax 517.546.9388 | www.centurionmp.<strong>com</strong><br />
©2011 Centurion <strong>Med</strong>ical Products Corporation LIT132V1