Download PDF

Download PDF Download PDF

sp.salesmrc.com
from sp.salesmrc.com More from this publisher
26.06.2015 Views

"B" DATA SHEET Specifications & Performance Certified Quality Model SB1 & SB25 3 2 1 Metallic Design Level 5 Quality System ISO9001 Certified AIR EXHAUST 3/4" NPT D Environmental Management System ISO14001 Certified AIR INLET 1/2" NPT C 6.89 175 Warren Rupp, Inc. A Unit of IDEX Corporation 800 N. Main St., Mansfield, Ohio 44902 USA Telephone (419) 524.8388 Fax (419) 522.7867 WWW.SANDPIPERPUMP.COM © Copyright 2014 Warren Rupp, Inc. All rights reserved SB1 / SB25 HEAVY DUTY BALL VALVE PUMP DIMENSIONAL TOLERANCE 1/8 [3] [XX] = MILLIMETERS www.sandpiperpump.com B

"B"<br />

DATA SHEET<br />

Specifications & Performance<br />

Certified Quality<br />

Model SB1 & SB25<br />

3 2 1<br />

Metallic<br />

Design Level 5<br />

Quality System<br />

ISO9001 Certified<br />

AIR EXHAUST<br />

3/4" NPT<br />

D<br />

Environmental Management System<br />

ISO14001 Certified<br />

AIR INLET<br />

1/2" NPT<br />

C<br />

6.89<br />

175<br />

Warren Rupp, Inc.<br />

A Unit of IDEX Corporation<br />

800 N. Main St.,<br />

Mansfield, Ohio 44902 USA<br />

Telephone (419) 524.8388<br />

Fax (419) 522.7867<br />

WWW.SANDPIPERPUMP.COM<br />

© Copyright 2014 Warren Rupp, Inc.<br />

All rights reserved<br />

SB1 / SB25<br />

HEAVY DUTY BALL VALVE PUMP<br />

DIMENSIONAL TOLERANCE 1/8 [3]<br />

[XX] = MILLIMETERS<br />

www.sandpiperpump.com<br />

B


Explanation of Pump Nomenclature<br />

Your Model #:<br />

(fill in from pump<br />

nameplate)<br />

__ __ _____ __ ___ __ __<br />

Pump Pump Pump Size Discharge Diaphragm/ Design<br />

Series Design and Options Porting Valve Level<br />

Construction<br />

Model #: XX X XXXXXX, XX XXX X XX<br />

Pump Series<br />

S SANDPIPER ®<br />

Pump Design<br />

B Soilid Ball<br />

Pump Size<br />

1 1"<br />

25 1" BSPT (Tapered Thread)<br />

Discharge Porting Position<br />

D Bottom<br />

S Side<br />

T Top<br />

ET Dual Top<br />

ES Dual Side<br />

Options<br />

P1 Intrinsically Safe ATEX Compliant<br />

Pulse Output<br />

Diaphragm Check Valve Materials<br />

B Nitrile<br />

C FKM with PTFE<br />

F FDA Accepted White Nitrile<br />

GN Neoprene Backup with PTFE Overlay<br />

and PTFE Check Balls<br />

GR Hytrel Backup w/<br />

PTFE Overlay/PTFE Balls<br />

GZ PTFE/Nitrile Bonded<br />

One-Piece/PTFE Balls<br />

H EPDM with PTFE<br />

N Neoprene<br />

R Hytrel<br />

S Santoprene<br />

V FKM<br />

Design Level<br />

5<br />

Construction<br />

A Aluminum Wetted, Aluminum Air<br />

SI Stainless Steel Wetted, Cast Iron Air<br />

SS Stainless Steel Wetted, Aluminum Air<br />

HC Alloy-C Wetted, Aluminum Air<br />

HI Alloy-C Wetted, Cast Iron Air<br />

Your Serial #: (fill in from pump nameplate)______________________________________<br />

ATEX Detail<br />

(1)<br />

II 2GD II 1G T5c T5<br />

II 3/1 G c T5<br />

Doc. #203040000<br />

II 1D c T100°C<br />

I M1 c<br />

I M2 c<br />

II 2G c T5<br />

II 2GD T5<br />

II 3/2 G c T5<br />

Doc. #203040000 II 2D c T100°C<br />

Models equipped with Construction designations<br />

SI or HI. Note: See ATEX Explanation of Type<br />

Certificate<br />

Models equipped with Construction designations A,<br />

SI, SS, HC, or HI. Note: See ATEX Explanation of<br />

Type Examination Certificate<br />

II II 2G Ex Ex ia ia c c IIC IIC T5 T5<br />

(2)<br />

II 3/2 2D c G iaD Ex 20 ia IP67 c IIC T100˚C T5<br />

II 2D Ex c ia 20 IP67<br />

T100°C<br />

Note: Pumps ordered with the options listed in (1) to the left are<br />

ATEX compliant when ordered with kit option P1.<br />

1 • Model SB1 & SB25<br />

www.sandpiperpump.com<br />

sb1dl5ds-rev0714


Performance<br />

SB1 & SB25<br />

SUCTION/DISCHARGE PORT SIZE<br />

• SB1: 1” (25.4mm) NPT(F)<br />

• SB25: 1” (25.4mm) BSP Tapered<br />

CAPACITY<br />

• 0 to 42 gallons per minute<br />

(0 to 159 liters per minute)<br />

AIR DISTRIBUTION VALVE<br />

• No-lube, no-stall design<br />

SOLIDS-HANDLING<br />

• Up to nearly .25 in. (6.3mm)<br />

HEADS UP TO<br />

• 125 psi or 289 ft. of water<br />

(8.8 Kg/cm 2 or 88 meters)<br />

MAXIMUM OPERATING PRESSURE<br />

• 125 psi (8.6 bar)<br />

DISPLACEMENT/STROKE<br />

• .09 Gallon / .34 liter<br />

SHIPPING WEIGHT<br />

• Aluminum 31 lbs. (14kg)<br />

• Stainless Steel 45 lbs. (20kg)<br />

• Alloy C 45 lbs. (20kg)<br />

HEAD<br />

sb1dl5ds-rev0714<br />

BAR<br />

• Stainless Steel with Cast Iron Center 65 lbs. (30kg)<br />

• Alloy C with Cast Iron Center 65 lbs. (30kg)<br />

Materials<br />

Material Profile:<br />

7<br />

6<br />

5<br />

4<br />

3<br />

2<br />

1<br />

0<br />

PSI<br />

100<br />

90<br />

80<br />

CAUTION! Operating temperature limitations are as follows:<br />

Conductive Acetal: Tough, impact resistant, ductile. Good<br />

abrasion resistance and low friction surface. Generally inert, with<br />

good chemical resistance except for strong acids and oxidizing<br />

agents.<br />

EPDM: Shows very good water and chemical resistance. Has<br />

poor resistance to oils and solvents, but is fair in ketones and<br />

alcohols.<br />

FKM: (Fluorocarbon) Shows good resistance to a wide range<br />

of oils and solvents; especially all aliphatic, aromatic and<br />

halogenated hydrocarbons, acids, animal and vegetable oils.<br />

Hot water or hot aqueous solutions (over 70°F(21°C)) will<br />

attack FKM.<br />

Hytrel®: Good on acids, bases, amines and glycols at room<br />

temperatures only.<br />

Neoprene: All purpose. Resistance to vegetable oils. Generally<br />

not affected by moderate chemicals, fats, greases and many<br />

oils and solvents. Generally attacked by strong oxidizing acids,<br />

ketones, esters and nitro hydrocarbons and chlorinated aromatic<br />

hydrocarbons.<br />

Nitrile: General purpose, oil-resistant. Shows good solvent, oil,<br />

water and hydraulic fluid resistance. Should not be used with<br />

highly polar solvents like acetone and MEK, ozone, chlorinated<br />

hydrocarbons and nitro hydrocarbons.<br />

Nylon: 6/6 High strength and toughness over a wide<br />

temperature range. Moderate to good resistance to fuels, oils<br />

and chemicals.<br />

100 PSI<br />

80 PSI<br />

10(17)<br />

15(25.5)<br />

20(34)<br />

25(42.5)<br />

30(51)<br />

70<br />

60<br />

35(59.5)<br />

40(68)<br />

50<br />

45(76.5)<br />

40<br />

50(85)<br />

30<br />

20<br />

10<br />

0 0 4 8 12 16 20 24 28 32 36 40<br />

U.S. Gallons per minute<br />

60 PSI<br />

40 PSI<br />

AIR CONSUMPTION<br />

SCFM (M 3 /hr)<br />

20 PSI Air Inlet Pressure<br />

MODEL SB1/SB25 Performance Curve<br />

Performance based on the following: elastomer fitted pump, flooded suction,<br />

water at ambient conditions. The use of other materials and varying hydraulic<br />

conditions may result in deviations in excess of 5%.<br />

0 25 50 75 100 125 150<br />

Liters per minute<br />

CAPACITY<br />

Operating<br />

Temperatures:<br />

Max. Min.<br />

190°F<br />

88°C<br />

280°F<br />

138°C<br />

350°F<br />

177°C<br />

220°F<br />

104°C<br />

200°F<br />

93°C<br />

190°F<br />

88°C<br />

180°F<br />

82°C<br />

-20°F<br />

-29°C<br />

-40°F<br />

-40°C<br />

-40°F<br />

-40°C<br />

-20°F<br />

-29°C<br />

-10°F<br />

-23°C<br />

-10°F<br />

-23°C<br />

32°F<br />

0°C<br />

Polypropylene: A thermoplastic polymer. Moderate tensile<br />

and flex strength. Resists stong acids and alkali. Attacked by<br />

chlorine, fuming nitric acid and other strong oxidizing agents.<br />

PVDF: (Polyvinylidene Fluoride) A durable fluoroplastic with<br />

excellent chemical resistance. Excellent for UV applications.<br />

High tensile strength and impact resistance.<br />

Santoprene®: Injection molded thermoplastic elastomer with<br />

no fabric layer. Long mechanical flex life. Excellent abrasion<br />

resistance.<br />

UHMW PE: A thermoplastic that is highly resistant to a broad<br />

range of chemicals. Exhibits outstanding abrasion and impact<br />

resistance, along with environmental stress-cracking resistance.<br />

Urethane: Shows good resistance to abrasives. Has poor<br />

resistance to most solvents and oils.<br />

Virgin PTFE: (PFA/TFE) Chemically inert, virtually impervious.<br />

Very few chemicals are known to chemically react with PTFE;<br />

molten alkali metals, turbulent liquid or gaseous fluorine and<br />

a few fluoro-chemicals such as chlorine trifluoride or oxygen<br />

difluoride which readily liberate free fluorine at elevated<br />

temperatures.<br />

www.sandpiperpump.com Model SB1 & SB25 • 2<br />

180°F<br />

82°C<br />

250°F<br />

121°C<br />

275°F<br />

135°C<br />

180°F<br />

82°C<br />

150°F<br />

66°C<br />

220°F<br />

104°C<br />

32°F<br />

0°C<br />

0°F<br />

-18°C<br />

-40°F<br />

-40°C<br />

-35°F<br />

-37°C<br />

32°F<br />

0°C<br />

-35°F<br />

-37°C<br />

Maximum and Minimum Temperatures are the limits for which these materials can be operated.<br />

Temperatures coupled with pressure affect the longevity of diaphragm pump components.<br />

Maximum life should not be expected at the extreme limits of the temperature ranges.<br />

Metals:<br />

Alloy C: Equal to ASTM494 CW-12M-1 specification for nickel and nickel alloy.<br />

Stainless Steel: Equal to or exceeding ASTM specification A743 CF-8M for corrosion<br />

resistant iron chromium, iron chromium nickel and nickel based alloy castings for<br />

general applications. Commonly referred to as 316 Stainless Steel in the pump industry.<br />

For specific applications, always consult the Chemical Resistance Chart.<br />

Ambient temperature range: -20°C to +40°C<br />

Process temperature range: -20°C to +80°C for models rated as category 1 equipment<br />

-20°C to +100°C for models rated as category 2 equipment<br />

In addition, the ambient temperature range and the process temperature range do not exceed the operating temperature range of the applied non-metallic parts as listed in the manuals of the pumps.


Dimensional Drawings<br />

SB1 & SB25 Heavy Duty Ball Valve<br />

8 7 6 5 4 3<br />

11.36<br />

288<br />

DISCHARGE PORT<br />

1" NPT (SB1)<br />

1" BSPT (SB25)<br />

6.12<br />

155<br />

"C"<br />

"A"<br />

"B"<br />

AIR EXHAUST<br />

3/4" NPT<br />

6 5 4 3 2 1<br />

"C"<br />

"B"<br />

"D"<br />

DISCHARGE PORT<br />

1" NPT (SB1)<br />

1" BSPT (SB25)<br />

6.12<br />

155<br />

12.50<br />

317<br />

"A"<br />

AIR EXHAUST<br />

3/4" NPT<br />

AIR INLET<br />

1/2" NPT<br />

9.00<br />

229<br />

8<br />

12.50<br />

317<br />

4X<br />

4.63<br />

118<br />

.72<br />

18<br />

SUCTION PORT<br />

1" NPT (SB1)<br />

1" BSPT (SB25)<br />

.28 [7] MOUNTING HOLE<br />

NOTE:<br />

UNIT FURNISHED WITH SUB-BASE PLATE<br />

AND RUBBER FEET AS STANDARD. FOR<br />

STATIONARY BOLT DOWN USE, RUBBER<br />

FEET CAN BE REMOVED.<br />

8.56<br />

217<br />

7<br />

6<br />

4X<br />

4.63<br />

118<br />

.72<br />

18<br />

SUCTION PORT<br />

1" NPT (SB1) AIR INLET<br />

1" BSPT (SB25) 1/2" NPT<br />

6.89<br />

175<br />

.28 [7] MOUNTING HOLE<br />

NOTE:<br />

UNIT FURNISHED WITH SUB-BASE PLATE<br />

AND RUBBER FEET AS STANDARD. FOR<br />

STATIONARY BOLT DOWN USE, RUBBER<br />

FEET CAN BE REMOVED.<br />

PUMP<br />

COFIGURATION<br />

ALUMINUM<br />

CENTER SECTION<br />

SB1 / SB25<br />

HEAVY DUTY BALL VALVE PUMP<br />

DIMENSIONAL TOLERANCE 1/8 [3]<br />

[XX] = MILLIMETERS<br />

DIM "A" DIM "B" DIM "C" DIM "D"<br />

F.1 REVISED VALVE CONFIGURATION MF 11/9/2011<br />

6.89<br />

175<br />

PUMP<br />

COFIGURATION<br />

ALUMINUM<br />

CENTER SECTION<br />

3.95 [100] 5.86 [149] 13.90 [353] 14.55 [370]<br />

CAST IRON<br />

CENTER SECTION 4.10 [104] 5.54 [141] 13.60 [345] 15.75 [400]<br />

PULSE OUTPUT<br />

CONFIGURATION<br />

REV REVISION CHG DATE APP DATE ECN<br />

SB1 / SB<br />

HEAVY DUTY BALL VA<br />

DIMENSIONAL TOLERAN<br />

[XX] = MILLIMETE<br />

DIM "A"<br />

DIM "B"<br />

3.95 [100] 5.86 [149<br />

CAST IRON<br />

CENTER SECTION 4.10 [104] 5.54 [141<br />

PULSE OUTPUT<br />

CONFIGURATION<br />

PART NUMBER<br />

MATERIAL<br />

PUMP REFERENCE PR<br />

450.060.000<br />

MADE FROM<br />

6<br />

F.1 REVISED VALVE CONFIGURATION MF 11/9/2011<br />

REV REVISION CHG DATE APP DATE ECN<br />

PART NUMBER<br />

MADE FROM<br />

MATERIAL<br />

PUMP REFERENCE PROJECT<br />

450.060.000<br />

UNLESS OTHERWISE<br />

SPECIFIED<br />

TOLEARNCES<br />

WARREN RUPP , I<br />

.XX<br />

.XXX<br />

.010<br />

.005<br />

ANGULAR 1/2<br />

63<br />

SURFACE FINSH<br />

DO NOT SCALE DRAWING<br />

DIMENSIONS ARE INCHES<br />

THIS IS A PROPRIETARY DOCUMENT. DO NOT REPRODUCE OR DISCLOS<br />

EXPRESS WRITTEN PERMISSION OF WARREN RUPP, INC<br />

DESCRIPTION<br />

OUTLINE, DIMENSIONAL, SB1<br />

450.073.000<br />

DRAWING NUMBER<br />

SH<br />

3 • Model SB1 & SB25<br />

www.sandpiperpump.com<br />

sb1dl5ds-rev0714


11.36<br />

288<br />

"C"<br />

"B"<br />

"A"<br />

"D"<br />

"D"<br />

11.36<br />

288<br />

DISCHARGE PORT<br />

1" NPT (SB1)<br />

1" BSPT (SB25)<br />

DISCHARGE PORT<br />

1" NPT (SB1)<br />

1" BSPT (SB25)<br />

8.43<br />

214<br />

7.62<br />

194<br />

7.62<br />

194<br />

"C"<br />

"B"<br />

"A"<br />

AIR EXHAUST<br />

3/4" NPT<br />

AIR EXHAUST<br />

3/4" NPT<br />

AIR INLET<br />

1/2" NPT<br />

AIR INLET<br />

6.82 1/2" NPT<br />

173<br />

9.00<br />

229<br />

9.00<br />

229<br />

8.56<br />

217<br />

8.56<br />

217<br />

8.43<br />

214<br />

.64<br />

.72<br />

16<br />

18<br />

SUCTION PORT<br />

1" NPT (SB1)<br />

1" BSPT (SB25)<br />

.64<br />

.72<br />

16<br />

4X .28 [7] MOUNTING HOLE 18<br />

SUCTION PORT<br />

NOTE: 1" NPT (SB1)<br />

UNIT 1" FURNISHED BSPT (SB25) WITH SUB-BASE PLATE<br />

AND RUBBER FEET AS STANDARD. FOR<br />

STATIONARY BOLT DOWN USE, RUBBER<br />

4X FEET .28 CAN [7] MOUNTING BE REMOVED. HOLE<br />

NOTE:<br />

UNIT FURNISHED WITH SUB-BASE PLATE<br />

AND RUBBER FEET AS STANDARD. FOR<br />

STATIONARY BOLT DOWN USE, RUBBER HEAVY DUTY FLAP VALVE PUMP<br />

FEET CAN BE REMOVED.<br />

BOTTOM PORTED<br />

DIMENSIONAL TOLERANCE 1/8 [3]<br />

[XX] = MILLIMETERS<br />

PUMP<br />

COFIGURATION<br />

ALUMINUM<br />

CENTER SECTION<br />

6.82<br />

173<br />

DIM "A" DIM "B" DIM "C" DIM "D"<br />

HEAVY DUTY FLAP VALVE PUMP<br />

BOTTOM PORTED<br />

DIMENSIONAL TOLERANCE 1/8 [3]<br />

3.95 [100] 5.86 [149] 15.36 [390] 14.49 [368]<br />

CAST IRON<br />

[XX] = MILLIMETERS<br />

CENTER SECTION 4.10 [104] 5.54 [141] 15.06 [383] 15.69 [398]<br />

PULSE PUMP OUTPUT<br />

COFIGURATION<br />

CONFIGURATION DIM "A" DIM "B" DIM "C" DIM "D"<br />

ALUMINUM<br />

CENTER SECTION<br />

3.95 [100] 5.86 [149] 15.36 [390] 14.49 [368]<br />

CAST IRON<br />

CENTER SECTION 4.10 [104] 5.54 [141] 15.06 [383] 15.69 [398]<br />

PULSE OUTPUT<br />

CONFIGURATION


Written Warranty<br />

5 - YEAR Limited Product Warranty<br />

Quality System ISO9001 Certified • Environmental Management Systems ISO14001 Certified<br />

Warren Rupp, Inc. (“Warren Rupp”) warrants to the original end-use purchaser that no product sold by<br />

Warren Rupp that bears a Warren Rupp brand shall fail under normal use and service due to a defect in material<br />

or workmanship within five years from the date of shipment from Warren Rupp’s factory. Warren Rupp brands<br />

include SANDPIPER®, MARATHON®, PortaPump®, SludgeMaster and Tranquilizer®.<br />

~ See complete warranty at www. sandpiperpump.com/About/guaranteesandwarranties.html ~<br />

Declaration of Conformity<br />

Manufacturer: Warren Rupp, Inc. ® , 800 N. Main Street<br />

Mansfield, Ohio, 44902 USA<br />

Certifies that Air-Operated Double Diaphragm Pump Series: HDB, HDF, M Non-Metallic,<br />

S Non-Metallic, M Metallic, S Metallic, T Series, G Series, U Series, EH and SH High Pressure,<br />

RS Series, W Series, SMA and SPA Submersibles, and Tranquilizer Surge Suppressors comply with<br />

the European Community Directive 2006/42/EC on Machinery, according to Annex VIII.<br />

This product has used Harmonized Standard EN809:1998+A1:2009, Pumps and Pump Units<br />

for Liquids - Common Safety Requirements, to verify conformance.<br />

Signature of authorized person<br />

David Roseberry<br />

Printed name of authorized person<br />

October 20, 2005<br />

Date of issue<br />

Engineering Manager<br />

Title<br />

Revision Level: F<br />

August 23, 2012<br />

Date of revision


EC Declaration of Conformity<br />

In accordance with ATEX Directive 94/9/EC,<br />

Equipment intended for use in potentially explosive environments.<br />

Manufacturer: Warren Rupp, Inc. ® , A Unit of IDEX Corportion<br />

800 North Main Street, P.O. Box 1568, Mansfield, OH 44902 USA<br />

EN 60079-25: 2004<br />

For pumps equipped with Pulse Output ATEX Option<br />

KEMA Quality B.V. (0344)<br />

AODD Pumps and Surge Suppressors<br />

For Type Examination Designations<br />

Applicable Standard:<br />

EN13463-1: 2001,<br />

EN13463-5: 2003<br />

AODD (Air-Operated Double Diaphragm) Pumps<br />

EC Type Examination Certificate No. Pumps: KEMA 09ATEX0071 X<br />

KEMA Quality B.V.<br />

Utrechtseweg 310<br />

6812 AR Arnhem, The Netherlands<br />

DATE/APPROVAL/TITLE:<br />

27 MAY 2010<br />

EC Declaration of Conformity<br />

David Roseberry, Engineering Manager<br />

David Roseberry, Engineering Manager<br />

ATEX Summary of Markings<br />

Type Marking Listed In<br />

Pump types, S1F, S15, S20,<br />

and S30 provided with the<br />

pulse output option<br />

Pump types, S1F, S15, S20,<br />

and S30 provided with the<br />

integral solenoid option<br />

Pump types, HDB1½, HDB40,<br />

HDB2, HDB50, HDB3, HDF1,<br />

HDF25, HDF2, HDF3M, PB¼,<br />

S05, S1F, S15, S20, S30, SB1,<br />

SB25, ST1½, ST40, G15, G20,<br />

and G30, without the above<br />

listed options, no aluminum<br />

parts<br />

Pump types, DMF2, DMF3,<br />

HDB1½, HDB40, HDB2,<br />

HDB50, HDB3, HDF1, HDF25,<br />

HDF2, HDF3M, PB¼, S05, S1F,<br />

S15, S20, S30, SB1, SB25,<br />

SE½, ST1, ST25, ST1½, ST40,<br />

U1F, G05, G1F, G15, G20, and<br />

G30<br />

Surge Suppressors all types<br />

Applicable Standard:<br />

EN13463-1: 2001,<br />

EN13463-5: 2003<br />

EC Type Certificate No. Pumps: KEMA 09ATEX0071 X<br />

Type Certificate No. Pumps: KEMA 09ATEX0072 X<br />

Type Certificate No. Suppressors: KEMA 09ATEX0073<br />

II 2 G Ex ia c IIC T5<br />

II 3/2 G Ex ia c IIC T5<br />

II 2 D Ex c iaD 20 IP67 T100 o C<br />

II 2 G EEx m c II T5<br />

II 3/2 G EEx m c II T5<br />

II 2 D c IP65 T100 o C<br />

II 1 G c T5<br />

II 3/1 G c T5<br />

II 1 D c T100 o C<br />

I M1 c<br />

I M2 c<br />

II 2 G c T5<br />

II 3/2 G c T5<br />

II 2 D c T100 o C<br />

II 2 G T5<br />

II 3/2 G T5<br />

II 2 D T100 o C<br />

DATE/APPROVAL/TITLE:<br />

27 MAY 2010<br />

KEMA 09ATEX0071 X<br />

CE 0344<br />

KEMA 09ATEX0073<br />

CE<br />

KEMA 09ATEX0071 X<br />

KEMA 09ATEX0071 X<br />

KEMA 09ATEX0071 X<br />

KEMA 09ATEX0071 X KEMA 09ATEX0071 X<br />

CE 0344<br />

KEMA 09ATEX0071 X<br />

KEMA 09ATEX0071 X<br />

KEMA 09ATEX0071 X KEMA 09ATEX0071 X<br />

KEMA 09ATEX0072 X KEMA 09ATEX0071 X<br />

CE 0344<br />

KEMA 09ATEX0071 X<br />

KEMA 09ATEX0071 X<br />

KEMA 09ATEX0072 X<br />

KEMA 09ATEX0072 X KEMA 09ATEX0072 X<br />

CE<br />

KEMA 09ATEX0072 X<br />

KEMA 09ATEX0072 X<br />

In accordance with ATEX Directive 94/9/EC,<br />

Equipment intended for use in potentially explosive environments.<br />

KEMA 09ATEX0073<br />

KEMA 09ATEX0073<br />

KEMA 09ATEX0073<br />

EC Declaration of Conformity<br />

Non-Conductive<br />

Fluids<br />

No<br />

Yes<br />

Yes<br />

AODD (Air-Operated Double Diaphragm) Pumps<br />

EC Type Examination Certificate No. Pumps: KEMA 09ATEX0071 X<br />

KEMA Quality B.V.<br />

Utrechtseweg 310<br />

6812 AR Arnhem, The Netherlands<br />

No<br />

Yes<br />

Yes<br />

No<br />

Yes<br />

Yes<br />

No<br />

Yes<br />

AODD Pumps and Surge Suppressors<br />

For Type Examination Designations, see page 2 (back)<br />

EN 60079-25: 2004<br />

For pumps equipped with Pulse Output ATEX Option<br />

KEMA Quality B.V. (0344)<br />

Manufacturer: Warren Rupp, Inc. ® , A Unit of IDEX Corportion<br />

800 North Main Street, P.O. Box 1568, Mansfield, OH 44901-1568 USA<br />

No<br />

Yes<br />

Yes<br />

No<br />

Yes<br />

Yes<br />

Pumps marked with equipment Category II 3/1 G (internal 3 G / eternal 1 G), 1D, M1 and M2 when<br />

used for non-conductive fluids. The pumps are Category II 2 G when used for conductive fluids.<br />

Pumps and surge suppressors marked with equipment Category II 3/2 (internal 3 G / external 2 G), 2D<br />

when used for non-conductive fluids. The pumps are Category II 2 G when used for conductive fluids.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!