Installation Guide for VIRDI-4000 V3.1 Fingerprint Identification ...
Installation Guide for VIRDI-4000 V3.1 Fingerprint Identification ...
Installation Guide for VIRDI-4000 V3.1 Fingerprint Identification ...
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
<strong>Installation</strong> <strong>Guide</strong> <strong>for</strong> <strong>VIRDI</strong>-<strong>4000</strong> <strong>V3.1</strong><br />
<strong>Fingerprint</strong> <strong>Identification</strong> Terminal<br />
Doc. Ver. : V1.32<br />
Sep.,04.2008<br />
R&D Center<br />
Union Community Co., Ltd.
1. External Connectors<br />
Phone+ (RE) - 2<br />
Phone- (BK) - 1<br />
P - 2<br />
P - 1<br />
Door Phone<br />
Interface<br />
GND (BK) - 2<br />
+12V (RE) - 1<br />
P - 3<br />
P - 2<br />
P - 1<br />
Power Adapter<br />
Interface<br />
GND (BK) - 7<br />
Exit B (OR) - 6<br />
GND (BK) - 5<br />
Input2 (GR) - 4<br />
Input1 (YE) - 3<br />
Lock2 (BR) - 2<br />
Lock1 (RE) - 1<br />
P - 7<br />
P - 6<br />
P - 5<br />
P - 4<br />
P - 3<br />
P - 2<br />
P - 1<br />
Door Lock/Control Input<br />
Interface<br />
<strong>Installation</strong> <strong>for</strong> <strong>VIRDI</strong>-<strong>4000</strong><br />
<strong>V3.1</strong><br />
2
1. External Connectors<br />
1 – (BR) Wie IN0<br />
2 – (RE) Wie IN1<br />
3 – (OR) Wie OUT0<br />
4 – (YE) Wie OUT1<br />
5 – (BK) GND<br />
Wiegand<br />
Interface<br />
10Base-T Ethernet<br />
Interface (RJ45)<br />
<strong>Installation</strong> <strong>for</strong> <strong>VIRDI</strong>-<strong>4000</strong><br />
<strong>V3.1</strong><br />
3
2. Connecting Ethernet (LAN) Cable<br />
UTP 10Base-T<br />
Switch Hub or Hub<br />
RJ45<br />
** UTP Connector<br />
<strong>Installation</strong> <strong>for</strong> <strong>VIRDI</strong>-<strong>4000</strong><br />
<strong>V3.1</strong><br />
4
3. Main Board Feature<br />
J101 Wiegand IN/OUT<br />
J501 Ethernet<br />
Lock 1<br />
Lock 2<br />
Input 1<br />
Input 2<br />
RS485B<br />
RS485A<br />
DC12V<br />
GND<br />
F.GND<br />
GND<br />
Exit Button<br />
: Lock Control Output<br />
: Lock Control Output<br />
: Door Monitor Input 1<br />
: Door Monitor Input 2<br />
: RS-485 B<br />
: RS-485 A<br />
: DC 12V Input<br />
: DC Input Ground<br />
: Field Ground<br />
: Inside Open GND<br />
: Inside Open Exit Button<br />
J101 Wiegand IN/Out :<br />
1 : Wiegnad IN 0 ( Brown )<br />
2 : Wiegand IN 1 ( Red )<br />
3 : Wiegand Out 0 ( Orange )<br />
4 : Wiegand Out 1 ( Yellow )<br />
5 : Ground ( Black )<br />
SW101 RS232 Level Select<br />
Switch Setting I [ RS-232 Level Selection ]<br />
SW101 : Default Setting =>1,4 :ON<br />
Serial0 => 232 Driver Level : 1:ON, 2:OFF<br />
232 TTL Level : 1:OFF, 2:ON<br />
Serial1 => 232 Driver Level : 3:ON, 4:OFF<br />
232 TTL Level : 3:OFF, 4:ON<br />
SW201,204 Lock Type Switch<br />
SW202,203 Lock Type Switch<br />
SW102 RS485 Termination<br />
Resistor Select Switch<br />
F251 Fuse<br />
J251 5V Output<br />
Switch Setting II [ Lock Type Selection ]<br />
SW201 : NO [ Normal Open Relay Contact ]<br />
NC [ Normal Close Relay Contact ]<br />
SW202 : ST/M [ Strike/Motor/Dead-Bolt Lock ]<br />
A/D [ Auto Door Selection ]<br />
SW203 : Strike [ Strike, Auto Door, Dead bolt ]<br />
Motor [ Motor Lock Selection ]<br />
SW204 : ST/M [ Strike/Motor/Dead-bolt Lock ]<br />
A/D [ Auto Door Selection ]<br />
Switch Setting III [ Lock Type Selection ]<br />
SW201 : ON [ 120ohm termination resistor ]<br />
OFF [ Open the termination resistor ]<br />
SW2 Lock Type Switch<br />
RV201 Volume Control<br />
J301 Keypad Interface<br />
J302 <strong>Fingerprint</strong> Sensor<br />
SW2 Dip Switch : Default Setting =>3:ON<br />
1 : Option ( RS485 Product ID )<br />
2 : Option ( RS485 Product ID )<br />
3 : Motor (on) / Strike (off) Select<br />
4 : Reserved<br />
5 : Reserved<br />
6 : Reserved<br />
<strong>Installation</strong> <strong>for</strong> <strong>VIRDI</strong>-<strong>4000</strong><br />
<strong>V3.1</strong><br />
5
4. Keypad Board Feature<br />
RV352 Approach Sensor Distance Control<br />
Low<br />
High<br />
J359 UV LED Interface<br />
J353 RF/Smart Card Interface<br />
J352 LCD Interface I<br />
J353 LCD Interface II<br />
J356 Touch Sensor<br />
High<br />
J358 Reed Switch<br />
J360 Touch 2nd<br />
J355 Speaker<br />
Low<br />
J357 Doorphone<br />
Interface<br />
J351 Main Board<br />
Interface<br />
RV351 LCD contrast Control<br />
<strong>Installation</strong> <strong>for</strong> <strong>VIRDI</strong>-<strong>4000</strong><br />
<strong>V3.1</strong><br />
6
5. Schematic <strong>for</strong> Door Lock Interface<br />
ST/MT<br />
AutoDoor<br />
LockCon1<br />
SW202<br />
BSI-10<br />
R228<br />
1<br />
472R<br />
2 B<br />
1 2<br />
R229<br />
473R<br />
D201<br />
S1A<br />
VIN<br />
5V<br />
A K<br />
E C<br />
VIN<br />
DC210<br />
104C2<br />
1<br />
2<br />
Q203<br />
KN2222AS<br />
1<br />
2<br />
Door Lock Interface<br />
LM_COM2<br />
K201<br />
G6S-2-5VDC<br />
10<br />
9<br />
8<br />
4<br />
1<br />
12<br />
DC211<br />
104C2<br />
3<br />
5<br />
NC<br />
SW203<br />
BSI-10<br />
SW201<br />
BSI-10<br />
NO<br />
D202<br />
S1A<br />
A K<br />
1<br />
2<br />
Motor<br />
Strike/AutoDoor<br />
Lock1<br />
PV204<br />
VN20-260LJ<br />
D204<br />
S1A<br />
5V<br />
A K<br />
DC215<br />
104C2<br />
1<br />
2<br />
K202<br />
G6S-2-5VDC<br />
10<br />
9<br />
8<br />
4<br />
1<br />
12<br />
3<br />
5<br />
VIN<br />
1<br />
AutoDoor<br />
LM_COM2<br />
Strike/Motor<br />
SW204<br />
BSI-10<br />
Strike/Motor<br />
Lock2<br />
D205<br />
S1A<br />
A K<br />
1<br />
2<br />
PV206<br />
VN20-260LJ<br />
LockCon2<br />
R241<br />
1<br />
472R<br />
2<br />
1 2<br />
R240<br />
473R<br />
B<br />
E C<br />
Q205<br />
KN2222AS<br />
Strike/Motor<br />
2<br />
DC216<br />
104C2<br />
<strong>Installation</strong> <strong>for</strong> <strong>VIRDI</strong>-<strong>4000</strong><br />
<strong>V3.1</strong><br />
7
6. Connections of harness to terminal blocks<br />
Door Lock<br />
Cable<br />
P-<br />
P-<br />
P-<br />
P-<br />
P-<br />
P-<br />
P-<br />
1<br />
2<br />
3<br />
4<br />
5<br />
6<br />
7<br />
(BK)<br />
(OR)<br />
(BK)<br />
(GR)<br />
(YE)<br />
(BR)<br />
(RE)<br />
RS485<br />
Cable<br />
P-<br />
P-<br />
P-<br />
1<br />
2<br />
(BK)<br />
(RE)<br />
3<br />
Power Cable<br />
GND<br />
Exit B<br />
FG<br />
GND<br />
+12V<br />
RS485.A<br />
RS485.B<br />
Input2<br />
Input1<br />
Lock.2<br />
Lock.1<br />
<strong>Installation</strong> <strong>for</strong> <strong>VIRDI</strong>-<strong>4000</strong><br />
<strong>V3.1</strong><br />
8
7. Connecting Door Phone<br />
7 Pin Door Lock<br />
Housing<br />
P-7 (BK)<br />
P-6 (OR)<br />
** Inside Open Switch Connection<br />
P-7 (BK)<br />
P-6 (OR)<br />
Door Phone<br />
Housing<br />
※ The <strong>Installation</strong> distance is Max 30M(100feet) between <strong>VIRDI</strong>-<strong>4000</strong> and Door Phone.<br />
If you want to call the door phone, please use the “Call” button.<br />
<strong>Installation</strong> <strong>for</strong> <strong>VIRDI</strong>-<strong>4000</strong><br />
<strong>V3.1</strong><br />
9
8. Connecting Dead-Bolt Type Door Lock (Fail Safe)<br />
8.1. Connect with One System/ One Lock<br />
ON<br />
Lock Type Select S/W<br />
NO<br />
SW2<br />
SW201<br />
NC<br />
SW204<br />
ST/M<br />
A/D<br />
SW202<br />
A/D<br />
SW203<br />
Strike<br />
ST/M<br />
Motor<br />
- C +<br />
ON<br />
WnP<br />
1 2 3 4<br />
Door Monitor<br />
(-)Black<br />
(+)Red<br />
1 2 3 4 5 6<br />
Lock 1 (RE) - 1<br />
Lock 2 (BR) - 2<br />
Input1 (YE) - 3<br />
Input2 (GR) - 4<br />
GND (BK) - 5<br />
Exit B (OR) - 6<br />
GND (BK) - 7<br />
Pin1<br />
Pin3<br />
Pin5<br />
Pin6<br />
Pin7<br />
Lock(+)<br />
Input1<br />
Lock(-)<br />
Exit B<br />
GND<br />
Inside Door Open S/W<br />
<strong>Installation</strong> <strong>for</strong> <strong>VIRDI</strong>-<strong>4000</strong><br />
<strong>V3.1</strong><br />
10
8. Connecting Dead-Bolt Type Door Lock (Fail Safe)<br />
8.2. Connect with Two Systems/ One Lock<br />
ON<br />
System 1<br />
Lock Type Select S/W<br />
NO<br />
SW2<br />
SW201<br />
NC<br />
SW204<br />
ST/M<br />
A/D<br />
SW202<br />
A/D<br />
SW203<br />
Strike<br />
ST/M<br />
Motor<br />
ON<br />
System 2<br />
Lock Type Select S/W<br />
NO<br />
SW2<br />
SW201<br />
NC<br />
SW204<br />
ST/M<br />
A/D<br />
SW202<br />
A/D<br />
SW203<br />
Strike<br />
ST/M<br />
Motor<br />
- C +<br />
ON<br />
WnP<br />
1 2 3 4<br />
(-)Black<br />
(+)Red<br />
Door Monitor<br />
1 2 3 4 5 6<br />
1 2 3 4 5 6<br />
Lock(+)<br />
Lock(+)<br />
Lock(-)<br />
Lock(-)<br />
Pin1<br />
Pin3<br />
Input1<br />
Input1<br />
Lock 1 (RE) - 1<br />
Lock 2 (BR) - 2<br />
Input1 (YE) - 3<br />
Input2 (GR) - 4<br />
GND (BK) - 5<br />
Exit B (OR) - 6<br />
GND (BK) - 7<br />
Lock 1 (RE) - 1<br />
Lock 2 (BR) - 2<br />
Input1 (YE) - 3<br />
Input2 (GR) - 4<br />
GND (BK) - 5<br />
Exit B (OR) - 6<br />
GND (BK) - 7<br />
Pin5<br />
Pin1<br />
Pin2<br />
Pin3<br />
System 1<br />
System 2<br />
<strong>Installation</strong> <strong>for</strong> <strong>VIRDI</strong>-<strong>4000</strong><br />
<strong>V3.1</strong><br />
11
9. Connecting Strike Type Door Lock (Fail Safe)<br />
9.1. Connect with One system/ One Lock<br />
Lock Type Select S/W<br />
SW201<br />
SW204<br />
ST/M<br />
(-)Black<br />
(+)Red<br />
ON<br />
NO<br />
SW2<br />
NC<br />
A/D<br />
SW202<br />
A/D<br />
SW203<br />
Strike<br />
ST/M<br />
Motor<br />
1 2 3 4 5 6<br />
Lock(+)<br />
Lock(-)<br />
Input1<br />
Door Monitor<br />
Pin6<br />
Exit B<br />
Pin1<br />
GND<br />
Inside Door Open S/W<br />
Lock 1 (RE) - 1<br />
Lock 2 (BR) - 2<br />
Input1 (YE) - 3<br />
Input2 (GR) - 4<br />
GND (BK) - 5<br />
Exit B (OR) - 6<br />
GND (BK) - 7<br />
Pin3<br />
Pin5<br />
Pin7<br />
<strong>Installation</strong> <strong>for</strong> <strong>VIRDI</strong>-<strong>4000</strong><br />
<strong>V3.1</strong><br />
12
9. Connecting Strike Type Door Lock (Fail Safe)<br />
9.2. Connect with Two systems/ One Lock<br />
ON<br />
System 1<br />
Lock Type Select S/W<br />
NO<br />
SW2<br />
SW201<br />
NC<br />
SW204<br />
ST/M<br />
A/D<br />
SW202<br />
A/D<br />
SW203<br />
Strike<br />
ST/M<br />
Motor<br />
ON<br />
System 2<br />
Lock Type Select S/W<br />
NO<br />
SW2<br />
SW201<br />
NC<br />
SW204<br />
ST/M<br />
A/D<br />
SW202<br />
A/D<br />
SW203<br />
Strike<br />
ST/M<br />
Motor<br />
(-)Black<br />
(+)Red<br />
1 2 3 4 5 6<br />
1 2 3 4 5 6<br />
Lock(+)<br />
Lock(+)<br />
Pin1<br />
Lock(-)<br />
Input1<br />
Lock(-)<br />
Input1<br />
Door Monitor<br />
Lock 1 (RE) - 1<br />
Lock 2 (BR) - 2<br />
Input1 (YE) - 3<br />
Input2 (GR) - 4<br />
GND (BK) - 5<br />
Exit B (OR) - 6<br />
GND (BK) - 7<br />
Lock 1 (RE) - 1<br />
Lock 2 (BR) - 2<br />
Input1 (YE) - 3<br />
Input2 (GR) - 4<br />
GND (BK) - 5<br />
Exit B (OR) - 6<br />
GND (BK) - 7<br />
Pin3<br />
Pin5<br />
Pin1<br />
Pin2<br />
Pin3<br />
System 1<br />
System 2<br />
<strong>Installation</strong> <strong>for</strong> <strong>VIRDI</strong>-<strong>4000</strong><br />
<strong>V3.1</strong><br />
13
10. Connecting Strike Type Door Lock (Fail Secure)<br />
10.1. Connect with One system/ One Lock<br />
Lock Type Select S/W<br />
ON<br />
NO<br />
SW2<br />
SW201<br />
NC<br />
SW204<br />
ST/M<br />
A/D<br />
SW202<br />
A/D<br />
SW203<br />
Strike<br />
ST/M<br />
Motor<br />
(-)Black<br />
(+)Red<br />
1 2 3 4 5 6<br />
Lock(+)<br />
Lock(-)<br />
Pin1<br />
Input1<br />
Exit B<br />
GND<br />
Door Monitor<br />
Inside Door Open S/W<br />
Lock 1 (RE) - 1<br />
Lock 2 (BR) - 2<br />
Input1 (YE) - 3<br />
Input2 (GR) - 4<br />
GND (BK) - 5<br />
Exit B (OR) - 6<br />
GND (BK) - 7<br />
Pin3<br />
Pin5<br />
Pin6<br />
Pin7<br />
<strong>Installation</strong> <strong>for</strong> <strong>VIRDI</strong>-<strong>4000</strong><br />
<strong>V3.1</strong><br />
14
10. Connecting Strike Type Door Lock (Fail Secure)<br />
ON<br />
10.2. Connect with Two systems/ One Lock<br />
System 1<br />
Lock Type Select S/W<br />
NO<br />
SW2<br />
SW201<br />
NC<br />
SW204<br />
ST/M<br />
A/D<br />
SW202<br />
A/D<br />
SW203<br />
Strike<br />
ST/M<br />
Motor<br />
ON<br />
System 2<br />
Lock Type Select S/W<br />
NO<br />
SW2<br />
SW201<br />
NC<br />
SW204<br />
ST/M<br />
A/D<br />
SW202<br />
A/D<br />
SW203<br />
Strike<br />
ST/M<br />
Motor<br />
(-)Black<br />
(+)Red<br />
1 2 3 4 5 6<br />
1 2 3 4 5 6<br />
Lock(+)<br />
Lock(+)<br />
Lock(-)<br />
Lock(-)<br />
Pin1<br />
Input1<br />
Input1<br />
Door Monitor<br />
Lock 1 (RE) - 1<br />
Lock 2 (BR) - 2<br />
Input1 (YE) - 3<br />
Input2 (GR) - 4<br />
GND (BK) - 5<br />
Exit B (OR) - 6<br />
GND (BK) - 7<br />
Lock 1 (RE) - 1<br />
Lock 2 (BR) - 2<br />
Input1 (YE) - 3<br />
Input2 (GR) - 4<br />
GND (BK) - 5<br />
Exit B (OR) - 6<br />
GND (BK) - 7<br />
Pin3<br />
Pin5<br />
Pin1<br />
Pin3<br />
Pin5<br />
System 1<br />
System 2<br />
<strong>Installation</strong> <strong>for</strong> <strong>VIRDI</strong>-<strong>4000</strong><br />
<strong>V3.1</strong><br />
15
11. Connecting EM Type Door Lock (Fail Safe)<br />
11.1. Connect with One system/ One Lock<br />
Lock Type Select S/W<br />
SW201<br />
SW204<br />
ST/M<br />
ON<br />
NO<br />
SW2<br />
NC<br />
A/D<br />
SW202<br />
A/D<br />
SW203<br />
Strike<br />
ST/M<br />
Motor<br />
- (Black)<br />
+ (Red)<br />
1 2 3 4 5 6<br />
Lock(+)<br />
Lock(-)<br />
Pin6<br />
Input1<br />
Exit B<br />
Door Monitor<br />
Pin1<br />
GND<br />
Inside Door Open S/W<br />
Lock 1 (RE) - 1<br />
Lock 2 (BR) - 2<br />
Input1 (YE) - 3<br />
Input2 (GR) - 4<br />
GND (BK) - 5<br />
Exit B (OR) - 6<br />
GND (BK) - 7<br />
Pin3<br />
Pin5<br />
Pin7<br />
<strong>Installation</strong> <strong>for</strong> <strong>VIRDI</strong>-<strong>4000</strong><br />
<strong>V3.1</strong><br />
16
11. Connecting EM Type Door Lock(Fail Safe)<br />
11.2. Connect with Two System/ One Lock<br />
System 1<br />
Lock Type Select S/W<br />
SW201<br />
SW204<br />
ST/M<br />
System 2<br />
Lock Type Select S/W<br />
SW201<br />
SW204<br />
ST/M<br />
ON<br />
NO<br />
SW2<br />
NC<br />
A/D<br />
SW202<br />
A/D<br />
SW203<br />
Strike<br />
ST/M<br />
Motor<br />
ON<br />
NO<br />
SW2<br />
NC<br />
A/D<br />
SW202<br />
A/D<br />
SW203<br />
Strike<br />
ST/M<br />
Motor<br />
- (Black)<br />
+ (Red)<br />
1 2 3 4 5 6<br />
1 2 3 4 5 6<br />
Lock(+)<br />
Lock(+)<br />
Lock(-)<br />
Lock(-)<br />
Pin1<br />
Input1<br />
Input1<br />
Lock+ (RE) - 1<br />
Lock- (BR) - 2<br />
Input1 (YE) - 3<br />
Input2 (GR) - 4<br />
GND (BK) - 5<br />
Exit B (OR) - 6<br />
GND (BK) - 7<br />
Lock+ (RE) - 1<br />
Lock- (BR) - 2<br />
Input1 (YE) - 3<br />
Input2 (GR) - 4<br />
GND (BK) - 5<br />
Exit B (OR) - 6<br />
GND (BK) - 7<br />
Pin2<br />
Pin3<br />
Pin1<br />
Pin2<br />
Pin3<br />
Door Monitor<br />
System 1<br />
System 2<br />
<strong>Installation</strong> <strong>for</strong> <strong>VIRDI</strong>-<strong>4000</strong><br />
<strong>V3.1</strong><br />
17
11. Connecting EM Type Door Lock (Fail Safe)<br />
11.3. Connect with One system/ Two Locks ** Use external DC Power adapter<br />
Lock Type Select S/W<br />
SW201<br />
SW204<br />
ST/M<br />
Lock 1<br />
ON<br />
NO<br />
SW2<br />
NC<br />
A/D<br />
SW202<br />
A/D<br />
SW203<br />
Strike<br />
ST/M<br />
Motor<br />
- (Black)<br />
12V 3A<br />
Adapter<br />
(-)<br />
(+)<br />
1 2 3 4 5 6<br />
Lock(-)<br />
Lock(+)<br />
+ (Red)<br />
Input1<br />
Door Monitor<br />
Exit B<br />
Pin1<br />
Pin2<br />
Pin3<br />
Pin6<br />
Pin7<br />
GND<br />
Inside Door Open S/W<br />
Lock 1 (RE) - 1<br />
Lock 2 (BR) - 2<br />
Input1 (YE) - 3<br />
Input2 (GR) - 4<br />
GND (BK) - 5<br />
Exit B (OR) - 6<br />
GND (BK) - 7<br />
Lock 2<br />
<strong>Installation</strong> <strong>for</strong> <strong>VIRDI</strong>-<strong>4000</strong><br />
<strong>V3.1</strong><br />
18
12. Connecting Auto-Door<br />
(Contact Control)<br />
12.1. Connect with One system/ One Door<br />
Lock Type Select S/W<br />
Auto Door Operating Part<br />
Auto Door Motor<br />
ON<br />
NO<br />
SW2<br />
SW201<br />
NC<br />
SW204<br />
ST/M<br />
A/D<br />
SW202<br />
A/D<br />
SW203<br />
Strike<br />
ST/M<br />
Motor<br />
Auto-Door Sensor<br />
9P CONN<br />
Sensor Input Line<br />
Auto-Door Monitor<br />
1 2 3 4 5 6<br />
Lock(+)<br />
Lock(-)<br />
Inside Door Open S/W<br />
Lock 1 (RE) - 1<br />
Lock 2 (BR) - 2<br />
Input1 (YE) - 3<br />
Input2 (GR) - 4<br />
GND (BK) - 5<br />
Exit B (OR) - 6<br />
GND (BK) - 7<br />
Pin1<br />
Pin2<br />
<strong>Installation</strong> <strong>for</strong> <strong>VIRDI</strong>-<strong>4000</strong><br />
<strong>V3.1</strong><br />
19
12. Connecting Auto-Door (Contact Control)<br />
12.2. Connect with Two systems/ One Door<br />
System 1 System 2<br />
Lock Type Select S/W<br />
Lock Type Select S/W<br />
SW201<br />
SW204<br />
ST/M<br />
SW201<br />
SW204<br />
ST/M<br />
ON<br />
NO<br />
SW2<br />
NC<br />
A/D<br />
SW202<br />
A/D<br />
SW203<br />
Strike<br />
ST/M<br />
Motor<br />
ON<br />
NO<br />
SW2<br />
NC<br />
A/D<br />
SW202<br />
A/D<br />
SW203<br />
Strike<br />
ST/M<br />
Motor<br />
Auto Door Operating Part<br />
Auto-Door Sensor<br />
Auto Door Motor<br />
Auto-Door Monitor<br />
1 2 3 4 5 6<br />
1 2 3 4 5 6<br />
Sensor Input Line<br />
9P CONN<br />
Lock(+)<br />
Lock(-)<br />
Lock(+)<br />
Lock(-)<br />
Lock 1 (RE) - 1<br />
Lock 2 (BR) - 2<br />
Input1 (YE) - 3<br />
Input2 (GR) - 4<br />
GND (BK) - 5<br />
Exit B (OR) - 6<br />
GND (BK) - 7<br />
Lock 1 (RE) - 1<br />
Lock 2 (BR) - 2<br />
Input1 (YE) - 3<br />
Input2 (GR) - 4<br />
GND (BK) - 5<br />
Exit B (OR) - 6<br />
GND (BK) - 7<br />
Pin1<br />
Pin2<br />
Pin1<br />
Pin2<br />
System 1<br />
System 2<br />
<strong>Installation</strong> <strong>for</strong> <strong>VIRDI</strong>-<strong>4000</strong><br />
<strong>V3.1</strong><br />
20
13. Connecting Motor Lock<br />
Lock Type Select S/W<br />
SW201<br />
SW204<br />
ST/M<br />
ON<br />
NO<br />
SW2<br />
NC<br />
A/D<br />
SW202<br />
A/D<br />
SW203<br />
Strike<br />
ST/M<br />
Motor<br />
Blue<br />
Brown<br />
Orange<br />
White<br />
Yellow<br />
Black<br />
1 2 3 4 5 6<br />
Lock 1 (RE) - 1<br />
Lock 2 (BR) - 2<br />
Input1 (YE) - 3<br />
Input2 (GR) - 4<br />
GND (BK) - 5<br />
Exit B (OR) - 6<br />
GND (BK) - 7<br />
Pin1<br />
Pin2<br />
Pin3<br />
Pin4<br />
Pin6<br />
Pin7<br />
Lock(+)<br />
Lock(-)<br />
Input1<br />
Input2<br />
Exit B<br />
GND<br />
Motor 1<br />
Motor 2<br />
Door Monitor<br />
Unlock Signal<br />
Ground<br />
Inside Door Open S/W<br />
<strong>Installation</strong> <strong>for</strong> <strong>VIRDI</strong>-<strong>4000</strong><br />
<strong>V3.1</strong><br />
21
14. Connecting 2 Emergency Lamps<br />
Lock Type Select S/W<br />
SW201<br />
SW204<br />
ST/M<br />
Emergency<br />
Lamp 1<br />
Emergency<br />
Lamp 2<br />
ON<br />
NO<br />
SW2<br />
NC<br />
A/D<br />
SW202<br />
A/D<br />
SW203<br />
Strike<br />
ST/M<br />
Motor<br />
1 2 3 4 5 6<br />
12 V (+) Ground (-) 12 V (+) Ground (-)<br />
Lock 1 (RE) - 1<br />
Lock 2 (BR) - 2<br />
Input1 (YE) - 3<br />
Input2 (GR) - 4<br />
GND (BK) - 5<br />
Exit B (OR) - 6<br />
GND (BK) - 7<br />
Pin1<br />
Pin2<br />
Pin5<br />
Pin7<br />
<strong>Installation</strong> <strong>for</strong> <strong>VIRDI</strong>-<strong>4000</strong><br />
<strong>V3.1</strong><br />
22