1. External Connectors<br />

Phone+ (RE) - 2<br />

Phone- (BK) - 1<br />

P - 2<br />

P - 1<br />

Door Phone<br />

Interface<br />

GND (BK) - 2<br />

+12V (RE) - 1<br />

P - 3<br />

P - 2<br />

P - 1<br />

Power Adapter<br />

Interface<br />

GND (BK) - 7<br />

Exit B (OR) - 6<br />

GND (BK) - 5<br />

Input2 (GR) - 4<br />

Input1 (YE) - 3<br />

Lock2 (BR) - 2<br />

Lock1 (RE) - 1<br />

P - 7<br />

P - 6<br />

P - 5<br />

P - 4<br />

P - 3<br />

P - 2<br />

P - 1<br />

Door Lock/Control Input<br />

Interface<br />

<strong>Installation</strong> <strong>for</strong> <strong>VIRDI</strong>-<strong>4000</strong><br />

<strong>V3.1</strong><br />

2


1. External Connectors<br />

1 – (BR) Wie IN0<br />

2 – (RE) Wie IN1<br />

3 – (OR) Wie OUT0<br />

4 – (YE) Wie OUT1<br />

5 – (BK) GND<br />

Wiegand<br />

Interface<br />

10Base-T Ethernet<br />

Interface (RJ45)<br />

<strong>Installation</strong> <strong>for</strong> <strong>VIRDI</strong>-<strong>4000</strong><br />

<strong>V3.1</strong><br />

3


2. Connecting Ethernet (LAN) Cable<br />

UTP 10Base-T<br />

Switch Hub or Hub<br />

RJ45<br />

** UTP Connector<br />

<strong>Installation</strong> <strong>for</strong> <strong>VIRDI</strong>-<strong>4000</strong><br />

<strong>V3.1</strong><br />

4


3. Main Board Feature<br />

J101 Wiegand IN/OUT<br />

J501 Ethernet<br />

Lock 1<br />

Lock 2<br />

Input 1<br />

Input 2<br />

RS485B<br />

RS485A<br />

DC12V<br />

GND<br />

F.GND<br />

GND<br />

Exit Button<br />

: Lock Control Output<br />

: Lock Control Output<br />

: Door Monitor Input 1<br />

: Door Monitor Input 2<br />

: RS-485 B<br />

: RS-485 A<br />

: DC 12V Input<br />

: DC Input Ground<br />

: Field Ground<br />

: Inside Open GND<br />

: Inside Open Exit Button<br />

J101 Wiegand IN/Out :<br />

1 : Wiegnad IN 0 ( Brown )<br />

2 : Wiegand IN 1 ( Red )<br />

3 : Wiegand Out 0 ( Orange )<br />

4 : Wiegand Out 1 ( Yellow )<br />

5 : Ground ( Black )<br />

SW101 RS232 Level Select<br />

Switch Setting I [ RS-232 Level Selection ]<br />

SW101 : Default Setting =>1,4 :ON<br />

Serial0 => 232 Driver Level : 1:ON, 2:OFF<br />

232 TTL Level : 1:OFF, 2:ON<br />

Serial1 => 232 Driver Level : 3:ON, 4:OFF<br />

232 TTL Level : 3:OFF, 4:ON<br />

SW201,204 Lock Type Switch<br />

SW202,203 Lock Type Switch<br />

SW102 RS485 Termination<br />

Resistor Select Switch<br />

F251 Fuse<br />

J251 5V Output<br />

Switch Setting II [ Lock Type Selection ]<br />

SW201 : NO [ Normal Open Relay Contact ]<br />

NC [ Normal Close Relay Contact ]<br />

SW202 : ST/M [ Strike/Motor/Dead-Bolt Lock ]<br />

A/D [ Auto Door Selection ]<br />

SW203 : Strike [ Strike, Auto Door, Dead bolt ]<br />

Motor [ Motor Lock Selection ]<br />

SW204 : ST/M [ Strike/Motor/Dead-bolt Lock ]<br />

A/D [ Auto Door Selection ]<br />

Switch Setting III [ Lock Type Selection ]<br />

SW201 : ON [ 120ohm termination resistor ]<br />

OFF [ Open the termination resistor ]<br />

SW2 Lock Type Switch<br />

RV201 Volume Control<br />

J301 Keypad Interface<br />

J302 <strong>Fingerprint</strong> Sensor<br />

SW2 Dip Switch : Default Setting =>3:ON<br />

1 : Option ( RS485 Product ID )<br />

2 : Option ( RS485 Product ID )<br />

3 : Motor (on) / Strike (off) Select<br />

4 : Reserved<br />

5 : Reserved<br />

6 : Reserved<br />

<strong>Installation</strong> <strong>for</strong> <strong>VIRDI</strong>-<strong>4000</strong><br />

<strong>V3.1</strong><br />

5


4. Keypad Board Feature<br />

RV352 Approach Sensor Distance Control<br />

Low<br />

High<br />

J359 UV LED Interface<br />

J353 RF/Smart Card Interface<br />

J352 LCD Interface I<br />

J353 LCD Interface II<br />

J356 Touch Sensor<br />

High<br />

J358 Reed Switch<br />

J360 Touch 2nd<br />

J355 Speaker<br />

Low<br />

J357 Doorphone<br />

Interface<br />

J351 Main Board<br />

Interface<br />

RV351 LCD contrast Control<br />

<strong>Installation</strong> <strong>for</strong> <strong>VIRDI</strong>-<strong>4000</strong><br />

<strong>V3.1</strong><br />

6


5. Schematic <strong>for</strong> Door Lock Interface<br />

ST/MT<br />

AutoDoor<br />

LockCon1<br />

SW202<br />

BSI-10<br />

R228<br />

1<br />

472R<br />

2 B<br />

1 2<br />

R229<br />

473R<br />

D201<br />

S1A<br />

VIN<br />

5V<br />

A K<br />

E C<br />

VIN<br />

DC210<br />

104C2<br />

1<br />

2<br />

Q203<br />

KN2222AS<br />

1<br />

2<br />

Door Lock Interface<br />

LM_COM2<br />

K201<br />

G6S-2-5VDC<br />

10<br />

9<br />

8<br />

4<br />

1<br />

12<br />

DC211<br />

104C2<br />

3<br />

5<br />

NC<br />

SW203<br />

BSI-10<br />

SW201<br />

BSI-10<br />

NO<br />

D202<br />

S1A<br />

A K<br />

1<br />

2<br />

Motor<br />

Strike/AutoDoor<br />

Lock1<br />

PV204<br />

VN20-260LJ<br />

D204<br />

S1A<br />

5V<br />

A K<br />

DC215<br />

104C2<br />

1<br />

2<br />

K202<br />

G6S-2-5VDC<br />

10<br />

9<br />

8<br />

4<br />

1<br />

12<br />

3<br />

5<br />

VIN<br />

1<br />

AutoDoor<br />

LM_COM2<br />

Strike/Motor<br />

SW204<br />

BSI-10<br />

Strike/Motor<br />

Lock2<br />

D205<br />

S1A<br />

A K<br />

1<br />

2<br />

PV206<br />

VN20-260LJ<br />

LockCon2<br />

R241<br />

1<br />

472R<br />

2<br />

1 2<br />

R240<br />

473R<br />

B<br />

E C<br />

Q205<br />

KN2222AS<br />

Strike/Motor<br />

2<br />

DC216<br />

104C2<br />

<strong>Installation</strong> <strong>for</strong> <strong>VIRDI</strong>-<strong>4000</strong><br />

<strong>V3.1</strong><br />

7


6. Connections of harness to terminal blocks<br />

Door Lock<br />

Cable<br />

P-<br />

P-<br />

P-<br />

P-<br />

P-<br />

P-<br />

P-<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

(BK)<br />

(OR)<br />

(BK)<br />

(GR)<br />

(YE)<br />

(BR)<br />

(RE)<br />

RS485<br />

Cable<br />

P-<br />

P-<br />

P-<br />

1<br />

2<br />

(BK)<br />

(RE)<br />

3<br />

Power Cable<br />

GND<br />

Exit B<br />

FG<br />

GND<br />

+12V<br />

RS485.A<br />

RS485.B<br />

Input2<br />

Input1<br />

Lock.2<br />

Lock.1<br />

<strong>Installation</strong> <strong>for</strong> <strong>VIRDI</strong>-<strong>4000</strong><br />

<strong>V3.1</strong><br />

8


7. Connecting Door Phone<br />

7 Pin Door Lock<br />

Housing<br />

P-7 (BK)<br />

P-6 (OR)<br />

** Inside Open Switch Connection<br />

P-7 (BK)<br />

P-6 (OR)<br />

Door Phone<br />

Housing<br />

※ The <strong>Installation</strong> distance is Max 30M(100feet) between <strong>VIRDI</strong>-<strong>4000</strong> and Door Phone.<br />

If you want to call the door phone, please use the “Call” button.<br />

<strong>Installation</strong> <strong>for</strong> <strong>VIRDI</strong>-<strong>4000</strong><br />

<strong>V3.1</strong><br />

9


8. Connecting Dead-Bolt Type Door Lock (Fail Safe)<br />

8.1. Connect with One System/ One Lock<br />

ON<br />

Lock Type Select S/W<br />

NO<br />

SW2<br />

SW201<br />

NC<br />

SW204<br />

ST/M<br />

A/D<br />

SW202<br />

A/D<br />

SW203<br />

Strike<br />

ST/M<br />

Motor<br />

- C +<br />

ON<br />

WnP<br />

1 2 3 4<br />

Door Monitor<br />

(-)Black<br />

(+)Red<br />

1 2 3 4 5 6<br />

Lock 1 (RE) - 1<br />

Lock 2 (BR) - 2<br />

Input1 (YE) - 3<br />

Input2 (GR) - 4<br />

GND (BK) - 5<br />

Exit B (OR) - 6<br />

GND (BK) - 7<br />

Pin1<br />

Pin3<br />

Pin5<br />

Pin6<br />

Pin7<br />

Lock(+)<br />

Input1<br />

Lock(-)<br />

Exit B<br />

GND<br />

Inside Door Open S/W<br />

<strong>Installation</strong> <strong>for</strong> <strong>VIRDI</strong>-<strong>4000</strong><br />

<strong>V3.1</strong><br />

10


8. Connecting Dead-Bolt Type Door Lock (Fail Safe)<br />

8.2. Connect with Two Systems/ One Lock<br />

ON<br />

System 1<br />

Lock Type Select S/W<br />

NO<br />

SW2<br />

SW201<br />

NC<br />

SW204<br />

ST/M<br />

A/D<br />

SW202<br />

A/D<br />

SW203<br />

Strike<br />

ST/M<br />

Motor<br />

ON<br />

System 2<br />

Lock Type Select S/W<br />

NO<br />

SW2<br />

SW201<br />

NC<br />

SW204<br />

ST/M<br />

A/D<br />

SW202<br />

A/D<br />

SW203<br />

Strike<br />

ST/M<br />

Motor<br />

- C +<br />

ON<br />

WnP<br />

1 2 3 4<br />

(-)Black<br />

(+)Red<br />

Door Monitor<br />

1 2 3 4 5 6<br />

1 2 3 4 5 6<br />

Lock(+)<br />

Lock(+)<br />

Lock(-)<br />

Lock(-)<br />

Pin1<br />

Pin3<br />

Input1<br />

Input1<br />

Lock 1 (RE) - 1<br />

Lock 2 (BR) - 2<br />

Input1 (YE) - 3<br />

Input2 (GR) - 4<br />

GND (BK) - 5<br />

Exit B (OR) - 6<br />

GND (BK) - 7<br />

Lock 1 (RE) - 1<br />

Lock 2 (BR) - 2<br />

Input1 (YE) - 3<br />

Input2 (GR) - 4<br />

GND (BK) - 5<br />

Exit B (OR) - 6<br />

GND (BK) - 7<br />

Pin5<br />

Pin1<br />

Pin2<br />

Pin3<br />

System 1<br />

System 2<br />

<strong>Installation</strong> <strong>for</strong> <strong>VIRDI</strong>-<strong>4000</strong><br />

<strong>V3.1</strong><br />

11


9. Connecting Strike Type Door Lock (Fail Safe)<br />

9.1. Connect with One system/ One Lock<br />

Lock Type Select S/W<br />

SW201<br />

SW204<br />

ST/M<br />

(-)Black<br />

(+)Red<br />

ON<br />

NO<br />

SW2<br />

NC<br />

A/D<br />

SW202<br />

A/D<br />

SW203<br />

Strike<br />

ST/M<br />

Motor<br />

1 2 3 4 5 6<br />

Lock(+)<br />

Lock(-)<br />

Input1<br />

Door Monitor<br />

Pin6<br />

Exit B<br />

Pin1<br />

GND<br />

Inside Door Open S/W<br />

Lock 1 (RE) - 1<br />

Lock 2 (BR) - 2<br />

Input1 (YE) - 3<br />

Input2 (GR) - 4<br />

GND (BK) - 5<br />

Exit B (OR) - 6<br />

GND (BK) - 7<br />

Pin3<br />

Pin5<br />

Pin7<br />

<strong>Installation</strong> <strong>for</strong> <strong>VIRDI</strong>-<strong>4000</strong><br />

<strong>V3.1</strong><br />

12


9. Connecting Strike Type Door Lock (Fail Safe)<br />

9.2. Connect with Two systems/ One Lock<br />

ON<br />

System 1<br />

Lock Type Select S/W<br />

NO<br />

SW2<br />

SW201<br />

NC<br />

SW204<br />

ST/M<br />

A/D<br />

SW202<br />

A/D<br />

SW203<br />

Strike<br />

ST/M<br />

Motor<br />

ON<br />

System 2<br />

Lock Type Select S/W<br />

NO<br />

SW2<br />

SW201<br />

NC<br />

SW204<br />

ST/M<br />

A/D<br />

SW202<br />

A/D<br />

SW203<br />

Strike<br />

ST/M<br />

Motor<br />

(-)Black<br />

(+)Red<br />

1 2 3 4 5 6<br />

1 2 3 4 5 6<br />

Lock(+)<br />

Lock(+)<br />

Pin1<br />

Lock(-)<br />

Input1<br />

Lock(-)<br />

Input1<br />

Door Monitor<br />

Lock 1 (RE) - 1<br />

Lock 2 (BR) - 2<br />

Input1 (YE) - 3<br />

Input2 (GR) - 4<br />

GND (BK) - 5<br />

Exit B (OR) - 6<br />

GND (BK) - 7<br />

Lock 1 (RE) - 1<br />

Lock 2 (BR) - 2<br />

Input1 (YE) - 3<br />

Input2 (GR) - 4<br />

GND (BK) - 5<br />

Exit B (OR) - 6<br />

GND (BK) - 7<br />

Pin3<br />

Pin5<br />

Pin1<br />

Pin2<br />

Pin3<br />

System 1<br />

System 2<br />

<strong>Installation</strong> <strong>for</strong> <strong>VIRDI</strong>-<strong>4000</strong><br />

<strong>V3.1</strong><br />

13


10. Connecting Strike Type Door Lock (Fail Secure)<br />

10.1. Connect with One system/ One Lock<br />

Lock Type Select S/W<br />

ON<br />

NO<br />

SW2<br />

SW201<br />

NC<br />

SW204<br />

ST/M<br />

A/D<br />

SW202<br />

A/D<br />

SW203<br />

Strike<br />

ST/M<br />

Motor<br />

(-)Black<br />

(+)Red<br />

1 2 3 4 5 6<br />

Lock(+)<br />

Lock(-)<br />

Pin1<br />

Input1<br />

Exit B<br />

GND<br />

Door Monitor<br />

Inside Door Open S/W<br />

Lock 1 (RE) - 1<br />

Lock 2 (BR) - 2<br />

Input1 (YE) - 3<br />

Input2 (GR) - 4<br />

GND (BK) - 5<br />

Exit B (OR) - 6<br />

GND (BK) - 7<br />

Pin3<br />

Pin5<br />

Pin6<br />

Pin7<br />

<strong>Installation</strong> <strong>for</strong> <strong>VIRDI</strong>-<strong>4000</strong><br />

<strong>V3.1</strong><br />

14


10. Connecting Strike Type Door Lock (Fail Secure)<br />

ON<br />

10.2. Connect with Two systems/ One Lock<br />

System 1<br />

Lock Type Select S/W<br />

NO<br />

SW2<br />

SW201<br />

NC<br />

SW204<br />

ST/M<br />

A/D<br />

SW202<br />

A/D<br />

SW203<br />

Strike<br />

ST/M<br />

Motor<br />

ON<br />

System 2<br />

Lock Type Select S/W<br />

NO<br />

SW2<br />

SW201<br />

NC<br />

SW204<br />

ST/M<br />

A/D<br />

SW202<br />

A/D<br />

SW203<br />

Strike<br />

ST/M<br />

Motor<br />

(-)Black<br />

(+)Red<br />

1 2 3 4 5 6<br />

1 2 3 4 5 6<br />

Lock(+)<br />

Lock(+)<br />

Lock(-)<br />

Lock(-)<br />

Pin1<br />

Input1<br />

Input1<br />

Door Monitor<br />

Lock 1 (RE) - 1<br />

Lock 2 (BR) - 2<br />

Input1 (YE) - 3<br />

Input2 (GR) - 4<br />

GND (BK) - 5<br />

Exit B (OR) - 6<br />

GND (BK) - 7<br />

Lock 1 (RE) - 1<br />

Lock 2 (BR) - 2<br />

Input1 (YE) - 3<br />

Input2 (GR) - 4<br />

GND (BK) - 5<br />

Exit B (OR) - 6<br />

GND (BK) - 7<br />

Pin3<br />

Pin5<br />

Pin1<br />

Pin3<br />

Pin5<br />

System 1<br />

System 2<br />

<strong>Installation</strong> <strong>for</strong> <strong>VIRDI</strong>-<strong>4000</strong><br />

<strong>V3.1</strong><br />

15


11. Connecting EM Type Door Lock (Fail Safe)<br />

11.1. Connect with One system/ One Lock<br />

Lock Type Select S/W<br />

SW201<br />

SW204<br />

ST/M<br />

ON<br />

NO<br />

SW2<br />

NC<br />

A/D<br />

SW202<br />

A/D<br />

SW203<br />

Strike<br />

ST/M<br />

Motor<br />

- (Black)<br />

+ (Red)<br />

1 2 3 4 5 6<br />

Lock(+)<br />

Lock(-)<br />

Pin6<br />

Input1<br />

Exit B<br />

Door Monitor<br />

Pin1<br />

GND<br />

Inside Door Open S/W<br />

Lock 1 (RE) - 1<br />

Lock 2 (BR) - 2<br />

Input1 (YE) - 3<br />

Input2 (GR) - 4<br />

GND (BK) - 5<br />

Exit B (OR) - 6<br />

GND (BK) - 7<br />

Pin3<br />

Pin5<br />

Pin7<br />

<strong>Installation</strong> <strong>for</strong> <strong>VIRDI</strong>-<strong>4000</strong><br />

<strong>V3.1</strong><br />

16


11. Connecting EM Type Door Lock(Fail Safe)<br />

11.2. Connect with Two System/ One Lock<br />

System 1<br />

Lock Type Select S/W<br />

SW201<br />

SW204<br />

ST/M<br />

System 2<br />

Lock Type Select S/W<br />

SW201<br />

SW204<br />

ST/M<br />

ON<br />

NO<br />

SW2<br />

NC<br />

A/D<br />

SW202<br />

A/D<br />

SW203<br />

Strike<br />

ST/M<br />

Motor<br />

ON<br />

NO<br />

SW2<br />

NC<br />

A/D<br />

SW202<br />

A/D<br />

SW203<br />

Strike<br />

ST/M<br />

Motor<br />

- (Black)<br />

+ (Red)<br />

1 2 3 4 5 6<br />

1 2 3 4 5 6<br />

Lock(+)<br />

Lock(+)<br />

Lock(-)<br />

Lock(-)<br />

Pin1<br />

Input1<br />

Input1<br />

Lock+ (RE) - 1<br />

Lock- (BR) - 2<br />

Input1 (YE) - 3<br />

Input2 (GR) - 4<br />

GND (BK) - 5<br />

Exit B (OR) - 6<br />

GND (BK) - 7<br />

Lock+ (RE) - 1<br />

Lock- (BR) - 2<br />

Input1 (YE) - 3<br />

Input2 (GR) - 4<br />

GND (BK) - 5<br />

Exit B (OR) - 6<br />

GND (BK) - 7<br />

Pin2<br />

Pin3<br />

Pin1<br />

Pin2<br />

Pin3<br />

Door Monitor<br />

System 1<br />

System 2<br />

<strong>Installation</strong> <strong>for</strong> <strong>VIRDI</strong>-<strong>4000</strong><br />

<strong>V3.1</strong><br />

17


11. Connecting EM Type Door Lock (Fail Safe)<br />

11.3. Connect with One system/ Two Locks ** Use external DC Power adapter<br />

Lock Type Select S/W<br />

SW201<br />

SW204<br />

ST/M<br />

Lock 1<br />

ON<br />

NO<br />

SW2<br />

NC<br />

A/D<br />

SW202<br />

A/D<br />

SW203<br />

Strike<br />

ST/M<br />

Motor<br />

- (Black)<br />

12V 3A<br />

Adapter<br />

(-)<br />

(+)<br />

1 2 3 4 5 6<br />

Lock(-)<br />

Lock(+)<br />

+ (Red)<br />

Input1<br />

Door Monitor<br />

Exit B<br />

Pin1<br />

Pin2<br />

Pin3<br />

Pin6<br />

Pin7<br />

GND<br />

Inside Door Open S/W<br />

Lock 1 (RE) - 1<br />

Lock 2 (BR) - 2<br />

Input1 (YE) - 3<br />

Input2 (GR) - 4<br />

GND (BK) - 5<br />

Exit B (OR) - 6<br />

GND (BK) - 7<br />

Lock 2<br />

<strong>Installation</strong> <strong>for</strong> <strong>VIRDI</strong>-<strong>4000</strong><br />

<strong>V3.1</strong><br />

18


12. Connecting Auto-Door<br />

(Contact Control)<br />

12.1. Connect with One system/ One Door<br />

Lock Type Select S/W<br />

Auto Door Operating Part<br />

Auto Door Motor<br />

ON<br />

NO<br />

SW2<br />

SW201<br />

NC<br />

SW204<br />

ST/M<br />

A/D<br />

SW202<br />

A/D<br />

SW203<br />

Strike<br />

ST/M<br />

Motor<br />

Auto-Door Sensor<br />

9P CONN<br />

Sensor Input Line<br />

Auto-Door Monitor<br />

1 2 3 4 5 6<br />

Lock(+)<br />

Lock(-)<br />

Inside Door Open S/W<br />

Lock 1 (RE) - 1<br />

Lock 2 (BR) - 2<br />

Input1 (YE) - 3<br />

Input2 (GR) - 4<br />

GND (BK) - 5<br />

Exit B (OR) - 6<br />

GND (BK) - 7<br />

Pin1<br />

Pin2<br />

<strong>Installation</strong> <strong>for</strong> <strong>VIRDI</strong>-<strong>4000</strong><br />

<strong>V3.1</strong><br />

19


12. Connecting Auto-Door (Contact Control)<br />

12.2. Connect with Two systems/ One Door<br />

System 1 System 2<br />

Lock Type Select S/W<br />

Lock Type Select S/W<br />

SW201<br />

SW204<br />

ST/M<br />

SW201<br />

SW204<br />

ST/M<br />

ON<br />

NO<br />

SW2<br />

NC<br />

A/D<br />

SW202<br />

A/D<br />

SW203<br />

Strike<br />

ST/M<br />

Motor<br />

ON<br />

NO<br />

SW2<br />

NC<br />

A/D<br />

SW202<br />

A/D<br />

SW203<br />

Strike<br />

ST/M<br />

Motor<br />

Auto Door Operating Part<br />

Auto-Door Sensor<br />

Auto Door Motor<br />

Auto-Door Monitor<br />

1 2 3 4 5 6<br />

1 2 3 4 5 6<br />

Sensor Input Line<br />

9P CONN<br />

Lock(+)<br />

Lock(-)<br />

Lock(+)<br />

Lock(-)<br />

Lock 1 (RE) - 1<br />

Lock 2 (BR) - 2<br />

Input1 (YE) - 3<br />

Input2 (GR) - 4<br />

GND (BK) - 5<br />

Exit B (OR) - 6<br />

GND (BK) - 7<br />

Lock 1 (RE) - 1<br />

Lock 2 (BR) - 2<br />

Input1 (YE) - 3<br />

Input2 (GR) - 4<br />

GND (BK) - 5<br />

Exit B (OR) - 6<br />

GND (BK) - 7<br />

Pin1<br />

Pin2<br />

Pin1<br />

Pin2<br />

System 1<br />

System 2<br />

<strong>Installation</strong> <strong>for</strong> <strong>VIRDI</strong>-<strong>4000</strong><br />

<strong>V3.1</strong><br />

20


13. Connecting Motor Lock<br />

Lock Type Select S/W<br />

SW201<br />

SW204<br />

ST/M<br />

ON<br />

NO<br />

SW2<br />

NC<br />

A/D<br />

SW202<br />

A/D<br />

SW203<br />

Strike<br />

ST/M<br />

Motor<br />

Blue<br />

Brown<br />

Orange<br />

White<br />

Yellow<br />

Black<br />

1 2 3 4 5 6<br />

Lock 1 (RE) - 1<br />

Lock 2 (BR) - 2<br />

Input1 (YE) - 3<br />

Input2 (GR) - 4<br />

GND (BK) - 5<br />

Exit B (OR) - 6<br />

GND (BK) - 7<br />

Pin1<br />

Pin2<br />

Pin3<br />

Pin4<br />

Pin6<br />

Pin7<br />

Lock(+)<br />

Lock(-)<br />

Input1<br />

Input2<br />

Exit B<br />

GND<br />

Motor 1<br />

Motor 2<br />

Door Monitor<br />

Unlock Signal<br />

Ground<br />

Inside Door Open S/W<br />

<strong>Installation</strong> <strong>for</strong> <strong>VIRDI</strong>-<strong>4000</strong><br />

<strong>V3.1</strong><br />

21


14. Connecting 2 Emergency Lamps<br />

Lock Type Select S/W<br />

SW201<br />

SW204<br />

ST/M<br />

Emergency<br />

Lamp 1<br />

Emergency<br />

Lamp 2<br />

ON<br />

NO<br />

SW2<br />

NC<br />

A/D<br />

SW202<br />

A/D<br />

SW203<br />

Strike<br />

ST/M<br />

Motor<br />

1 2 3 4 5 6<br />

12 V (+) Ground (-) 12 V (+) Ground (-)<br />

Lock 1 (RE) - 1<br />

Lock 2 (BR) - 2<br />

Input1 (YE) - 3<br />

Input2 (GR) - 4<br />

GND (BK) - 5<br />

Exit B (OR) - 6<br />

GND (BK) - 7<br />

Pin1<br />

Pin2<br />

Pin5<br />

Pin7<br />

<strong>Installation</strong> <strong>for</strong> <strong>VIRDI</strong>-<strong>4000</strong><br />

<strong>V3.1</strong><br />

22

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!