OPERATING AND MAINTENANCE INSTRUCTION ... - larius.org
OPERATING AND MAINTENANCE INSTRUCTION ... - larius.org
OPERATING AND MAINTENANCE INSTRUCTION ... - larius.org
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
STORM 4000<br />
O Correct procedure of decompression<br />
English<br />
• Lock the safety (O1) clamp of the gun.<br />
• Push the OFF (0) button (O2) switching the machine off.<br />
O2<br />
O1<br />
• Unlock the safety clamp (O1).<br />
O1<br />
O2<br />
ON (I)<br />
OFF (0)<br />
• Point the gun at a container.<br />
At the end lock the safety clamp again.<br />
• Push the levers (O3) and (O4) to discharghe the pressure.<br />
• Open the discharge valve (O5) to release the remaining<br />
pressure.<br />
O5<br />
O3<br />
O4<br />
WARNING:<br />
If the equipment is still under pressure after performing the operations above described<br />
because of the nozzle or the flexible hose clogged, proceed as follows:<br />
• Loosen very slowly the gun nozzle.<br />
• Release the clamp.<br />
• Point the gun at the container of the product and press the trigger to release<br />
pressure.<br />
• Loosen very slowly the fitting of connection from the flexible hose to the gun.<br />
• Clean or replace the flexible hose and the nozzle.<br />
14