MTP Instruments<br />
Innovative test instruments<br />
An innovative temperature logger is<br />
among the new measurement<br />
devices MTP Instruments will display<br />
at <strong>CMX</strong> <strong>2004</strong>.<br />
The PROVA 69 Portable Temperature<br />
Logger stands out because of its<br />
small size and user friendly interface.<br />
Temperature loggers are used when<br />
temperatures must be monitored over<br />
an extended period. For example, they<br />
can be placed with perishable foods in a<br />
refrigerated trailer to monitor for temperature<br />
fluctuations during a trip.<br />
They can also be placed in air ducts and<br />
ventilation rooms, or used in temperature<br />
surveys on buildings.<br />
Users can set maximums and minimums<br />
and the unit will time stamp up<br />
to 24 instances of temperatures outside<br />
of those limits, with duration.<br />
The PROVA 69 has a several security<br />
features to prevent man-made false<br />
data. These include a unique 48-bit serial<br />
number and a total samples (ever<br />
recorded) data counter. Also, any<br />
attempt to change a status register will<br />
stop the process of recording.<br />
Battery life is ten years.<br />
TES 3600 Power Analyzer<br />
The new TES 3600 Power Analyzer is<br />
lightweight and small enough to fit in<br />
your hand.<br />
The 3600 offers single-phase, 2-wire;<br />
single-phase, 3-wire; 3-phase, 3-wire,<br />
and 3-phase, 4-wire power measurement.<br />
It has connectors for four current<br />
sensing clamps to allow electrical measurements<br />
to be taken from up to four<br />
circuits (single-phase 2-wire) simultaneously.<br />
It measures KW, KVAR, KVA,<br />
PF, harmonics, Hz and energy KWh,<br />
KVARh and KVAh.<br />
It has an LCD display that shows 10<br />
readings at once, saving a lot of paging.<br />
Power analyzers are necessary when<br />
you want to conduct a consumption survey<br />
to identify machines that are using too<br />
A temperature/data logger is useful<br />
when temperatures must be monitored<br />
over an extended period.<br />
much electricity, or when you want to<br />
assess the quality of an energy source.<br />
The instruments are also useful for<br />
troubleshooting. For example, if a piece<br />
of sophisticated equipment is failing,<br />
the 3600 can monitor it to determine if<br />
voltage from the energy source is steady.<br />
Typical applications for a power analyzer<br />
include testing of heating and air conditioning<br />
units, and motor controllers.<br />
TES 3079 <strong>HVAC</strong><br />
TRMS Clamp Meter<br />
The TES 3079 is a complete tool for any<br />
technician in ventilation or air conditioning.<br />
It works as three units in one. It<br />
has the features of a clamp-on meter, a<br />
temperature indicator and microAmp<br />
capability.<br />
The unit analyzes temperature, voltage,<br />
amperage and resistance over hours<br />
or days and records the minimum and<br />
maximum with time stamping.<br />
A technician can use it to check current<br />
draw in motors and compressors,<br />
assess efficiency, check temperature, test<br />
run or start capacitors, confirm low voltage<br />
control signals, measure flame safeguard<br />
device current draw, and confirm<br />
power sources.<br />
It has a 3-3/4" digital LCD with a bar<br />
graph.<br />
TES 1326/1327 Infrared<br />
Temperature Gun<br />
Just point and pull the trigger, and the<br />
TES 1326/1327 Infrared Temperature<br />
Gun will tell you the surface temperature<br />
of ducts, pipes, steam traps, and<br />
more. Comfortable in your hand, the<br />
unit’s built-in laser sighting and 8:1<br />
ratio will save many trips up a ladder to<br />
measure airflow temperatures in heating<br />
and cooling ducts.<br />
Both the 1326 and 1327 operate in<br />
Fahrenheit or Centigrade, and have a<br />
back-lit LCD display, laser targeting and<br />
a Max/Min function. The 1327 also<br />
offers adjustable emissivity; an audible<br />
and visible alarm, and a data memory<br />
and read function.<br />
The units resolve temperature readings<br />
to within 1/10th of a degree C in a<br />
range from -20 to 500 degrees C. They<br />
weigh about 200 grams each.<br />
TES 3660 Autoranging<br />
Insulation Tester<br />
An insulation tester is an instrument used<br />
for checking insulation resistances on motors,<br />
compressors, feeders, buss bar systems,<br />
grounds, and branch circuit wiring.<br />
Most insulation testers are in trouble<br />
if there is voltage on the line, but not the<br />
TES 3660 Autoranging Insulation Tester.<br />
If it senses that the line is energized,<br />
it instantly switches from insulation<br />
testing mode (up to 4000 Mohm) to<br />
voltage testing mode (AC/DC, up to<br />
1000V). This uncommon safety feature<br />
prevents damage to the unit and helps<br />
the technician avoid shocks.<br />
The 3660 features a large LCD with<br />
analog bar graph and digital display. It has<br />
a 250V, 500V, 1000V output voltage for<br />
insulation Megaohm testing and a low<br />
ohm function for testing connections.<br />
Handheld, the device automatically<br />
discharges capacitive voltages, and has a<br />
manual data memory and read function<br />
with nine sets.<br />
The 3660 meets EN61557 and<br />
IEC1010-1, CAT III 1000V.<br />
Circle Number 144 for More Information<br />
42 <strong>Plumbing</strong> & <strong>HVAC</strong> Product News – March/April <strong>2004</strong> www.plumbingandhvac.ca