Chapter 7—Asynchronous Loads 7–31<br />

to be built in large quantities at acceptably low costs.<br />

Major difficulties seem to be in developing the metal to ceramic seals and in developing<br />

the β-alumina electrolyte. Corrosion is a major problem. One problem with the electrolyte<br />

is the tendency to accumulate metallic sodium along its grain boundaries, which shorts out<br />

the cell. These problems seem to have been largely overcome, so the beta battery may be a<br />

major contributor to utility load leveling and to wind energy systems in coming years.<br />

The number of possibilities for battery materials seems almost limitless[4]. The batteries<br />

discussed in this section seem to have the highest probability of wide use, but a technological<br />

breakthrough could easily move another battery type into the forefront. Whatever the<br />

ultimate winner is, these batteries will be used as system components, like transformers, by<br />

the utilities. If the utility has enough batteries on its system, it may not be necessary to<br />

physically place batteries at wind turbines for storage purposes. Of course, if it is desired to<br />

install large wind turbines on relatively low capacity distribution lines, batteries may be very<br />

helpful in matching the wind turbine to such a line.<br />

The engineer designing the battery installation will be concerned with a number of parameters,<br />

including the voltage, current, storage capacity in kWh or MWh, the energy density<br />

per unit area of base (footprint), weight, height, reliability, control, heating and cooling requirements,<br />

safety, and maintenance. If the batteries are to be installed at a typical utility<br />

substation, the desired total capacity will probably be 100 or 200 MWh. The total battery<br />

voltage will probably be in the range of 2000-3000 V dc. These voltages would make maximum<br />

use of modern power semiconductors and would reduce current requirements as compared with<br />

a lower voltage installation.<br />

A reasonable footprint is about 300 kWh/m 2 and a height of 6 m would probably be<br />

imposed by mechanical constraints. A height of 2 m may be better in terms of maintenance if<br />

the greater land area is available. The batteries should be capable of accepting a full charge in<br />

4 to 7 hours and should be able to deliver all their stored energy in as little as 3 hours. They<br />

should be capable of more than 2000 charge-discharge cycles and should have an useful life<br />

of more than ten years. The energy efficiency, defined as the ratio of the ac energy delivered<br />

during discharge to the ac energy supplied during charge, should be at least 70 percent. This<br />

definition of efficiency includes both the efficiency of the individual cells and the efficiency of<br />

the power conditioning equipment.<br />

Example<br />

Your company is considering installing a 100 MWh beta battery installation at a substation.<br />

Individual cells are 0.8 m tall and occupy a rectangular space that is 5 cm on a side. Each cell can<br />

store 200 Wh of energy. The energy efficiency is 70 percent, and you assume all the losses occur during<br />

the charge cycle. That is, if you put in 200/0.7 Wh during charge, you get back 200 Wh per cell on<br />

discharge. The battery installation is to be charged during a five hour period and discharged during a<br />

three hour period. Half the losses are used to maintain battery temperature and the other half can be<br />

used to provide thermal input to a 25 percent efficient turbine generator. The cells are to be mounted<br />

two high, so the total height requirement is less than 2 m. The battery voltage is 2500 V dc.<br />