final report<br />

4.6 Wiring examples<br />

IEC compatible charging station - schematics<br />

L3<br />

L2<br />

L1<br />

PEN<br />

10mm²<br />

service panel<br />

Note: mode 1 installations<br />

without any circuit brakers<br />

should no longer be used<br />

for public charging stations<br />

RCD<br />

F3<br />

6mm²<br />

10A/30mA - B<br />

1,5mm²<br />

X3<br />

0<br />

national<br />

socket outlet<br />

10 16 32<br />

A<br />

RCD<br />

F4<br />

16A/30mA<br />

2,5mm²<br />

IEC 309-2<br />

230V/16A<br />

L1<br />

PE<br />

N<br />

X2<br />

10 16<br />

0<br />

32<br />

A<br />

RCD<br />

32A/30mA - B<br />

F1<br />

4mm²<br />

4mm²<br />

K1<br />

solid state 50A<br />

+<br />

4mm²<br />

X1<br />

IEC 309-2<br />

compatible<br />

L1 N<br />

CPL PE<br />

PIN<br />

10 16<br />

0<br />

32<br />

A<br />

mode 3<br />

F2<br />

K2<br />

16A - B solid state 25A<br />

4mm²<br />

microsw.<br />

0<br />

10 16 32<br />

A<br />

mode 1<br />

+<br />

P1<br />

Wallbox Electronic<br />

0,5mm²<br />

1,5mm²<br />

0,5mm²<br />

16<br />

32A<br />

15<br />

16A<br />

CPL 17<br />

12<br />

L1<br />

13<br />

N<br />

MICROSW<br />

19<br />

0,5mm²<br />

S1<br />

14<br />

PE<br />

START<br />

18<br />

button switch<br />

full compliance to<br />

IEC 61851 <strong>and</strong> ENV 50275<br />

Figure 13: Wiring schematics for a full compatible charging station<br />

17/01/2008 28 Infrastructure for electrical vehicles