09.06.2015 Views

VHL2 LM-79-08 Test Report - Howard Lighting

VHL2 LM-79-08 Test Report - Howard Lighting

VHL2 LM-79-08 Test Report - Howard Lighting

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

IESNA <strong>LM</strong><strong>79</strong>-20<strong>08</strong><br />

TEST REPORT<br />

<strong>Report</strong> # 20130325JR-<strong>LM</strong><strong>79</strong><br />

<strong>Test</strong> Results –<br />

The following results were obtained after stabilization of the sample in accordance with the requirements set forth<br />

in section 5.0 of IES <strong>LM</strong><strong>79</strong>-20<strong>08</strong>. Stability is achieved when the variation of 3 readings of light output and electrical<br />

power over a period of 30 minutes, taken 15 minutes apart, is less than 0.5%.<br />

Photometric Results<br />

<strong>VHL2</strong>F67219540USVY10I<br />

Integrating Sphere<br />

Goniophotometer<br />

Total Luminous Flux (Lumens) 17850 17039<br />

Luminous Efficacy (Lumens / Watt) 81.5 76.4<br />

Total Radiant Flux (Watts) 53.429 -<br />

Correlated Color Temperature (CCT) 3903 -<br />

Color Rendering Index (CRI - R a ) 84.8 -<br />

R g Value 23.3 -<br />

Chromaticity (Chroma x / Chroma y) 0.387 / 0.3875 -<br />

Chromaticity (Chroma u / Chroma v) 0.2252 / 0.3381 -<br />

Chromaticity (Chroma u’ / Chroma v’) 0.2252 / 0.5072 -<br />

Duv Value 0.0029 -<br />

Expanded Uncertainty (k=2) (Percent) 2.1 2.8<br />

Electrical Results<br />

<strong>VHL2</strong>F67219540USVY10I<br />

Integrating Sphere<br />

Goniophotometer<br />

Input Power (Watts) (120/277V) 224.6 / 219.0 223.0<br />

Input Voltage (Volts AC) (120/277V) 120.0 / 277.0 120<br />

Input Current (Amps) (120/277V) 1.881 / .881 1.871<br />

Power Factor (120/277V) 99.5 / 89.7 99.3<br />

Input Frequency (Hertz) 60.0 60.0<br />

A-THD (Current %) (120/277V) 6.56 / 17.89 % N/A<br />

Additional Parameters<br />

<strong>VHL2</strong>F67219540USVY10I<br />

Integrating Sphere<br />

Goniophotometer<br />

Stabilization Time (Light and Power) 120 120<br />

<strong>Test</strong> Geometry Configuration 4π Type C<br />

Spectroradiometer Labsphere <strong>LM</strong>S-760 <strong>Lighting</strong> Sciences 6000<br />

Ambient Temperature 25.0 25.0<br />

ISTMT (In-Situ Temperature Measurement)<br />

Not <strong>Test</strong>ed<br />

Spacing Criteria<br />

N/A<br />

20130325JR-<strong>LM</strong><strong>79</strong><br />

Page 5 of 11<br />

LSI_<strong>Test</strong>_Number_T31606<br />

Confidential <strong>Report</strong>

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!