Specification <strong>Sheet</strong><br />

BALT5-500-ACTD<br />

Wiring Diagrams<br />

Contact customer service for wiring diagrams not shown.<br />

Emergency Ballast<br />

1. One Lamp Rapid Start Ballast<br />

BLACK<br />

WHITE<br />

RED<br />

RED<br />

AC<br />

BALLAST<br />

LAMP (emergency)<br />

BLUE<br />

BLUE<br />

BLUE<br />

BLUE/WHT<br />

RED/WHT<br />

RED<br />

YELLOW<br />

EMERGENCY<br />

BALLAST<br />

2 UNIT<br />

CONNECTOR<br />

BROWN (-)<br />

LED<br />

COMBO<br />

SWITCH<br />

VIOLET (+)<br />

3<br />

SWITCHED OR<br />

UNSWITCHED<br />

LINE<br />

ORANGE (277V)<br />

BLACK (120V)<br />

UNSWITCHED 1<br />

WHITE<br />

COMMON<br />

WHT/BLK<br />

1 SELECT PROPER VOLTAGE<br />

LEAD, CAP UNUSED LEAD<br />

2 DO NOT MATE CONNECTOR UNTIL<br />

INSTALLATION IS COMPLETE AND<br />

AC POWER IS SUPPLIED<br />

3 TEST ACCESSORY LEADS,<br />

REFER TO INSTALLATION<br />

INSTRUCTIONS FOR PROPER<br />

POLARITY WIRING<br />

2. Two Lamp Rapid Start Ballast (TypeA)<br />

BLACK<br />

WHITE<br />

YELLOW<br />

YELLOW<br />

AC<br />

BALLAST<br />

LAMP<br />

LAMP (emergency)<br />

BLUE<br />

BLUE<br />

RED<br />

RED<br />

BLUE<br />

BLUE/WHT<br />

RED/WHT<br />

RED<br />

YELLOW<br />

EMERGENCY<br />

BALLAST<br />

UNIT<br />

2 CONNECTOR<br />

BROWN (-)<br />

LED<br />

COMBO<br />

SWITCH<br />

VIOLET (+)<br />

3<br />

SWITCHED OR<br />

UNSWITCHED<br />

LINE<br />

ORANGE (277V)<br />

BLACK (120V)<br />

UNSWITCHED 1<br />

WHITE<br />

COMMON<br />

WHT/BLK<br />

1 SELECT PROPER VOLTAGE<br />

LEAD, CAP UNUSED LEAD<br />

2 DO NOT MATE CONNECTOR UNTIL<br />

INSTALLATION IS COMPLETE AND<br />

AC POWER IS SUPPLIED<br />

3 TEST ACCESSORY LEADS,<br />

REFER TO INSTALLATION<br />

INSTRUCTIONS FOR PROPER<br />

POLARITY WIRING<br />

AC/EMERGENCY<br />

AC/EMERGENCY<br />

3. Two Lamp Rapid Start Ballast (TypeB)<br />

4. Three Lamp Rapid Start Ballast (TypeA)<br />

BLACK<br />

WHITE<br />

YELLOW<br />

YELLOW<br />

AC<br />

BALLAST<br />

BLUE<br />

BLUE<br />

RED<br />

RED<br />

BLUE<br />

BLUE/WHT<br />

RED/WHT<br />

RED<br />

YELLOW<br />

EMERGENCY<br />

BALLAST<br />

SWITCHED OR<br />

UNSWITCHED<br />

LINE<br />

ORANGE (277V)<br />

BLACK (120V)<br />

UNSWITCHED 1<br />

WHITE<br />

COMMON<br />

WHT/BLK<br />

BLACK<br />

WHITE<br />

BLUE<br />

BLUE<br />

YELLOW<br />

YELLOW<br />

AC<br />

BALLAST<br />

BLUE/WHT<br />

BLUE/WHT<br />

RED<br />

RED<br />

BLUE<br />

BLUE/WHT<br />

RED/WHT<br />

RED<br />

YELLOW<br />

EMERGENCY<br />

BALLAST<br />

SWITCHED OR<br />

UNSWITCHED<br />

LINE<br />

ORANGE (277V)<br />

BLACK (120V)<br />

UNSWITCHED 1<br />

WHITE<br />

COMMON<br />

WHT/BLK<br />

LAMP<br />

LAMP (emergency)<br />

UNIT<br />

2 CONNECTOR<br />

BROWN (-)<br />

LED<br />

COMBO<br />

SWITCH<br />

VIOLET (+)<br />

3<br />

1 SELECT PROPER VOLTAGE<br />

LEAD, CAP UNUSED LEAD<br />

2 DO NOT MATE CONNECTOR UNTIL<br />

INSTALLATION IS COMPLETE AND<br />

AC POWER IS SUPPLIED<br />

3 TEST ACCESSORY LEADS,<br />

REFER TO INSTALLATION<br />

INSTRUCTIONS FOR PROPER<br />

POLARITY WIRING<br />

LAMP<br />

LAMP (emergency)<br />

LAMP<br />

UNIT<br />

2 CONNECTOR<br />

BROWN (-)<br />

LED<br />

COMBO<br />

SWITCH<br />

VIOLET (+)<br />

3<br />

1 SELECT PROPER VOLTAGE<br />

LEAD, CAP UNUSED LEAD<br />

2 DO NOT MATE CONNECTOR UNTIL<br />

INSTALLATION IS COMPLETE AND<br />

AC POWER IS SUPPLIED<br />

3 TEST ACCESSORY LEADS,<br />

REFER TO INSTALLATION<br />

INSTRUCTIONS FOR PROPER<br />

POLARITY WIRING<br />

AC/EMERGENCY<br />

AC/EMERGENCY<br />

5. Three Lamp Rapid Start Ballast (TypeB)<br />

6. Four Lamp Rapid Start Ballast<br />

BLACK<br />

WHITE<br />

BLUE<br />

BLUE<br />

BLUE/WHT<br />

BLUE/WHT<br />

AC<br />

BALLAST<br />

LAMP<br />

LAMP (emergency)<br />

LAMP<br />

SWITCHED OR<br />

UNSWITCHED<br />

LINE<br />

RED<br />

BLUE<br />

ORANGE (277V)<br />

RED<br />

BLUE/WHT<br />

BLACK (120V)<br />

UNSWITCHED 1<br />

RED/WHT EMERGENCY<br />

ORANGE<br />

WHITE<br />

ORANGE<br />

RED BALLAST<br />

COMMON<br />

YELLOW<br />

YELLOW<br />

WHT/BLK<br />

YELLOW<br />

BROWN<br />

BROWN 1 SELECT PROPER VOLTAGE<br />

LEAD, CAP UNUSED LEAD<br />

UNIT<br />

2 CONNECTOR<br />

2 DO NOT MATE CONNECTOR UNTIL<br />

INSTALLATION IS COMPLETE AND<br />

AC POWER IS SUPPLIED<br />

LED<br />

3 TEST ACCESSORY LEADS,<br />

COMBO<br />

REFER TO INSTALLATION<br />

SWITCH 3<br />

INSTRUCTIONS FOR PROPER<br />

POLARITY WIRING<br />

BROWN (-)<br />

VIOLET (+)<br />

BLACK<br />

WHITE<br />

BLUE/WHT<br />

BLUE/WHT<br />

ORANGE<br />

ORANGE<br />

AC<br />

BALLAST<br />

LAMP<br />

LAMP<br />

LAMP<br />

LAMP (emergency)<br />

YELLOW<br />

YELLOW<br />

BROWN<br />

BROWN<br />

BLUE<br />

BLUE<br />

RED<br />

RED<br />

BLUE<br />

BLUE/WHT<br />

RED/WHT<br />

RED<br />

YELLOW<br />

EMERGENCY<br />

BALLAST<br />

UNIT<br />

2 CONNECTOR<br />

BROWN (-)<br />

LED<br />

COMBO<br />

SWITCH<br />

VIOLET (+)<br />

3<br />

SWITCHED OR<br />

UNSWITCHED<br />

LINE<br />

ORANGE (277V)<br />

BLACK (120V)<br />

UNSWITCHED 1<br />

WHITE<br />

COMMON<br />

WHT/BLK<br />

1 SELECT PROPER VOLTAGE<br />

LEAD, CAP UNUSED LEAD<br />

2 DO NOT MATE CONNECTOR UNTIL<br />

INSTALLATION IS COMPLETE AND<br />

AC POWER IS SUPPLIED<br />

3 TEST ACCESSORY LEADS,<br />

REFER TO INSTALLATION<br />

INSTRUCTIONS FOR PROPER<br />

POLARITY WIRING<br />

AC/EMERGENCY<br />

AC/EMERGENCY<br />

7. One Lamp Instant Start Ballast<br />

8. Two Lamp Instant Start Ballast<br />

BLACK<br />

WHITE<br />

RED<br />

AC<br />

BALLAST<br />

BLUE<br />

3<br />

BLUE<br />

BLUE/WHT<br />

RED/WHT<br />

RED<br />

YELLOW<br />

EMERGENCY<br />

BALLAST<br />

SWITCHED OR<br />

UNSWITCHED<br />

LINE<br />

ORANGE (277V)<br />

BLACK (120V)<br />

UNSWITCHED 1<br />

WHITE<br />

COMMON<br />

WHT/BLK<br />

BLACK<br />

WHITE<br />

RED<br />

AC<br />

BALLAST<br />

BLUE<br />

BLUE<br />

3<br />

BLUE<br />

BLUE/WHT<br />

RED/WHT<br />

RED<br />

YELLOW<br />

EMERGENCY<br />

BALLAST<br />

SWITCHED OR<br />

UNSWITCHED<br />

LINE<br />

ORANGE (277V)<br />

BLACK (120V)<br />

UNSWITCHED 1<br />

WHITE<br />

COMMON<br />

WHT/BLK<br />

LAMP (emergency)<br />

AC/EMERGENCY<br />

UNIT<br />

2 CONNECTOR<br />

BROWN (-)<br />

LED<br />

COMBO<br />

SWITCH<br />

VIOLET (+)<br />

4<br />

1 SELECT PROPER VOLTAGE<br />

LEAD, CAP UNUSED LEAD<br />

2 DO NOT MATE CONNECTOR UNTIL<br />

INSTALLATION IS COMPLETE AND<br />

AC POWER IS SUPPLIED<br />

3 CONNECT BLUE/WHT AND RED/WHT<br />

WIRES TOGETHER<br />

4 TEST ACCESSORY LEADS,<br />

REFER TO INSTALLATION<br />

INSTRUCTIONS FOR PROPER<br />

POLARITY WIRING<br />

LAMP<br />

LAMP (emergency)<br />

AC/EMERGENCY<br />

UNIT<br />

2 CONNECTOR<br />

BROWN (-)<br />

LED<br />

COMBO<br />

SWITCH<br />

VIOLET (+)<br />

4<br />

1 SELECT PROPER VOLTAGE<br />

LEAD, CAP UNUSED LEAD<br />

2 DO NOT MATE CONNECTOR UNTIL<br />

INSTALLATION IS COMPLETE AND<br />

AC POWER IS SUPPLIED<br />

3 CONNECT BLUE/WHT AND RED/WHT<br />

WIRES TOGETHER<br />

4 TEST ACCESSORY LEADS,<br />

REFER TO INSTALLATION<br />

INSTRUCTIONS FOR PROPER<br />

POLARITY WIRING<br />

9. Three Lamp Instant Start Ballast<br />

10. Four Lamp Instant Start Ballast<br />

BLACK<br />

WHITE<br />

RED<br />

AC<br />

BALLAST<br />

BLUE<br />

BLUE<br />

BLUE<br />

3<br />

BLUE<br />

BLUE/WHT<br />

RED/WHT<br />

RED<br />

YELLOW<br />

EMERGENCY<br />

BALLAST<br />

SWITCHED OR<br />

UNSWITCHED<br />

LINE<br />

ORANGE (277V)<br />

BLACK (120V)<br />

UNSWITCHED 1<br />

WHITE<br />

COMMON<br />

WHT/BLK<br />

BLACK<br />

WHITE<br />

YELLOW<br />

YELLOW<br />

AC<br />

BALLAST<br />

BLUE<br />

BLUE<br />

RED<br />

RED<br />

3<br />

BLUE<br />

BLUE/WHT<br />

RED/WHT<br />

RED<br />

YELLOW<br />

EMERGENCY<br />

BALLAST<br />

SWITCHED OR<br />

UNSWITCHED<br />

LINE<br />

ORANGE (277V)<br />

BLACK (120V)<br />

UNSWITCHED 1<br />

WHITE<br />

COMMON<br />

WHT/BLK<br />

LAMP<br />

LAMP<br />

LAMP (emergency)<br />

AC/EMERGENCY<br />

UNIT<br />

2 CONNECTOR<br />

BROWN (-)<br />

LED<br />

COMBO<br />

SWITCH<br />

VIOLET (+)<br />

4<br />

1 SELECT PROPER VOLTAGE<br />

LEAD, CAP UNUSED LEAD<br />

2 DO NOT MATE CONNECTOR UNTIL<br />

INSTALLATION IS COMPLETE AND<br />

AC POWER IS SUPPLIED<br />

3 CONNECT BLUE/WHT AND RED/WHT<br />

WIRES TOGETHER<br />

4 TEST ACCESSORY LEADS,<br />

REFER TO INSTALLATION<br />

INSTRUCTIONS FOR PROPER<br />

POLARITY WIRING<br />

LAMP<br />

LAMP<br />

LAMP<br />

LAMP (emergency)<br />

AC/EMERGENCY<br />

UNIT<br />

2 CONNECTOR<br />

BROWN (-)<br />

LED<br />

COMBO<br />

SWITCH<br />

VIOLET (+)<br />

4<br />

1 SELECT PROPER VOLTAGE<br />

LEAD, CAP UNUSED LEAD<br />

2 DO NOT MATE CONNECTOR UNTIL<br />

INSTALLATION IS COMPLETE AND<br />

AC POWER IS SUPPLIED<br />

3 CONNECT BLUE/WHT AND RED/WHT<br />

WIRES TOGETHER<br />

4 TEST ACCESSORY LEADS,<br />

REFER TO INSTALLATION<br />

INSTRUCTIONS FOR PROPER<br />

POLARITY WIRING<br />

Specifications subject to change without notice.<br />

Howard Lighting Products | 580 Eastview Drive | Laurel, MS 39443<br />

(toll free) 800.956.3456 | (direct) 601.422.0033 | (fax) 601.422.1652<br />

www.HowardLightingProducts.com