The alarm precedence scheme precludes a sum zone from posting an alarm if any<br />

of its member detectors posts an alarm. The sum channel holds the lowest alarm<br />

precedence; it can alarm only if no higher-precedence (sum zone or singledetector)<br />

alarms are posted.<br />

Banner Messages<br />

The final edit submenu contains five lines of user-defined text messages which are<br />

displayed in rotation when the <strong>PCM</strong>-2 is not in use and is in the READY TO<br />

MEASURE state. Since these are text messages, the large computer keyboard is<br />

obviously used to enter them. This bulletin board feature may be used to post any<br />

brief messages to users of the <strong>PCM</strong>-2.<br />

<strong>PCM</strong>2.MANI REV AI April 1995 5-19