Hand Switch Req'd?<br />

Hip switch Req'd?<br />

L. Foot Switch Req'd?<br />

R. Foot Switch Req'd?<br />

Shoulder Switch Req'd?<br />

Access Control Option?<br />

Hi & La Level Password<br />

Any of the four standard body ( or one optional "Shoulder") position switches<br />

may be disabled. This will make the <strong>PCM</strong>-2 easier to operate if less precise body<br />

positioning is deemed acceptable.<br />

Setting this value to "YES" informs the instrument that an access control unit is<br />

present and must be controlled.<br />

These fields permit the entry of new four-digit values for the two test modes<br />

passwords. Current values are not shown.<br />

Day File Logging<br />

Transaction records, source check results, and status changes can be stored in<br />

daily disk files ("day files ") if the user so desires. This storage is enabled using<br />

the three menu items under the "Day File Directory Storage:" heading in the<br />

Instrument Configuration edit screen. The information is stored as follows:<br />

DayFileDirectory\DIRYY\MMDDYY.TXT - transaction record day file for<br />

day MMIDD/YY.<br />

DayFileDirectory\DIRYY\MMDDYY.SCK - source check results day file for<br />

day MMIDD/YY.<br />

DayFileDirectory\DIRYY\MMDDYY.CHG - status change day file for<br />

day MMIDD/YY.<br />

MM represents the month (01-12), DD represents the day (01-31), and YY<br />

represents the year (00 - 99) in which the information was stored. These files are<br />

stored in directory \DayFileDirectory\DIRYY, where, again, YY is the year the<br />

information was stored.<br />

The files are created when the first transaction, source check report, or status<br />

change is to be written to a day file. Subsequent transactions, source check<br />

reports, or status changes occurring on the same day will be appended to the same<br />

file.<br />

To use this feature, first specify a DayFileDirectory using the field "Day File<br />

Directory" in the Instrument Configuration edit screen. If this field is left blank,<br />

and day file storage is enabled, the files will be stored in MainDirectory\DIRYY,<br />

where MainDirectory is where the <strong>PCM</strong>-2 system files reside. The directory may<br />

specify a drive, but is only necessary if a drive other than the main drive is to be<br />

<strong>PCM</strong>2.MANI REV AI April 1995 5-17