Alpha & Beta RDAs<br />

Alpha & Beta<br />

Sensitivities<br />

RDA Confidence<br />

Count Time<br />

Sigma Factor<br />

Background<br />

Sigma Factor<br />

Alpha & Beta<br />

Sum Zone Alarm<br />

Alpha & Beta<br />

Sum Channel Alarm<br />

These are the Reliably Detectable Activities used to compute alarm setpoints for<br />

the alpha and beta channels. Values entered are copied to all alpha and beta<br />

detector channels; individual channel RDAs may later be changed in the Detector<br />

Parameters screen.<br />

A ratio above and below the mean of background counts beyond which a<br />

single detector's background is determined to be indicative of a detector failure.<br />

The default value is 0.5 for the beta channels, meaning that a detector with more<br />

than twice or less than half as many counts as the system average is considered<br />

suspect. Note that because the size, location and orientation of a detector affects<br />

its background counts, each detector has a Geometry Factor which is used to<br />

compensate for these variables. The default alpha sensitvity factor is 0.10.<br />

This is the probability of detecting contamination of the specified RDA. Possible<br />

values are 50 %, 75 %, 90 %, 95 %, 99 % and 99.9 %. Refer to the manual section<br />

on statistical algorithms for a detailed discussion of this parameter.<br />

The time (in seconds) for which all channels of the <strong>PCM</strong>-2 will count.<br />

A multiplier of the background count rate standard deviation which influences the<br />

false alarm rate. Refer to the section on statistical algorithms.<br />

If a background update count differs from the stored average background rate by<br />

this many standard deviations, the new rate immediately replaces the old. If the<br />

detector(s) on which this occurs alarmed on the last measurement, they are<br />

assumed to be contaminated.<br />

A sum zone is a user defined group of two to four detectors which are grouped<br />

together to enhance the monitor's ability to detect contamination spread over an<br />

area shared by several adjacent detectors. The alpha or beta sum zone alarm<br />

setpoint defines the activity required within the sum zone area before a sum zone<br />

alarm is triggered. Refer to the upcoming section or sum zone setup for more<br />

information on sum zones.<br />

A sum channel is a sum zone consisting of every channel in the monitor. The<br />

alpha or beta sum channel alarm setpoint is the activity which must be present<br />

within the entire monitor before the sum channel alarm is triggered.<br />