Optional Features<br />

Option 58<br />

As previously nored, the <strong>PCM</strong>-2 access control unit can be supplemented with<br />

three optional features:<br />

Remote Alarm Annunciator<br />

This option consists of a small remote module which visually displays a red light<br />

and emits an audible tone to communicate alarms for either an unauthorized exit<br />

from or an emergency exit gate lock override condition at an access control<br />

equipped <strong>PCM</strong>-2 unit. The remote alarm module features a push-button "Alarm<br />

Acknowledge" switch to manually interrupt the audible alarm tone and visual<br />

alarm light. The typical application for this remote alarm annunciator module is<br />

for installation in a guard station where remote monitoring of personnel egress<br />

from a single <strong>PCM</strong>-2 or from multiple <strong>PCM</strong>-2s is desirable. This option includes<br />

the interconnecting cable CA-109-XXFT (XX denotes cable length in feet) The<br />

length of this cable, up to a 200 ft. maximum, must be specified by the user when<br />

ordering this option. The remote alarm module(s) can simply set upright on any<br />

horizontal surface or up to four modules can be wall mounted with the use of an<br />

optional wall mounting fixture (Reference <strong>PCM</strong>2 OPT14, Remote Annunciator<br />

Wall Mount).<br />

Option 5C<br />

Local Alarm Beacon<br />

This accessory is simply a red strobe light which illuminates when the access<br />

control unit is in an emergency gate lock override status. The alarm beacon is<br />

mounted atop the access control unit on the upper cover panel providing<br />

maximum visibility to Health Safety personnel which may be monitoring the<br />

system nearby. This option is recommended for customers who intend to operate<br />

multiple <strong>PCM</strong>-2s with access control adjacent to one another in the same area so<br />

as to provide the capability of instant visual identification of a single alarmed unit.<br />

This option can be easily retrofitted to any access control unit in the field.<br />

Option 5D<br />

Remote Pull Station<br />

Marked with the familiar "Pull In Case Of Fire" lettering and equipped with a<br />

keylock reset, this remote switch is intended for installation in a guard station<br />

where remote override of one or multiple exit gate locks is necessary in the event<br />

of fire or other emergency situations which require immediate personnel egress.<br />

This option includes only the pull station switch itself which can be interwired<br />

with any number of <strong>PCM</strong>-2s. Since each customer facility will likely have their<br />

own unique interwiring requirements for this remote switch, no interconnecting<br />

cable is provided with the option. Eberline Customer Service and Engineering<br />

Groups are available to provide design recommendations/services for installation<br />

and interwiring of this safety related option.<br />

<strong>PCM</strong>2.MANi REV Ai April 1995 17-33