<strong>technical</strong> <strong>data</strong><br />

Systems<br />

Intelligent Touch Controller


•<br />

19<br />

1 Main features<br />

Survey..........................................................................................................................................................................2<br />

New functions .......................................................................................................................................................2<br />

2 System Overview..................................................................................................................3<br />

3 System Image<br />

Double intelligent touch Controllers ......................................................................................................4<br />

Options.......................................................................................................................................................................4<br />

4 Part Names and Functions<br />

Part Names and Functions.............................................................................................................................5<br />

Terminals on the Back of intelligent touch Controller................................................................6<br />

5 Part Names on the Monitoring Screen and the Functions.......................7<br />

6 Specifications...........................................................................................................................8<br />

7 Accessories................................................................................................................................8<br />

8 Dimensions ...............................................................................................................................9<br />

9 System Wiring......................................................................................................................10<br />

10 Power Proportional Distribution Card<br />

Function and Outline......................................................................................................................................11<br />

Preparation...........................................................................................................................................................12<br />

File Format.............................................................................................................................................................13<br />

• Systems • Control Systems 1


•<br />

1 Main features<br />

Intelligent Touch Controller is an advanced centralised control air conditioning management system that provides complete control for air conditioning<br />

equipment. This "all in one" graphic controller mounts neatly on any wall and takes up far less room space than BMS type systems.<br />

Intelligent Touch Controller incorporates a touch screen and colour LCD display - easy for any operator to use - whilst its unique Daikin DIII -NET wiring<br />

and all-in-one system, enables the Intelligent Touch Controller to be installed in no time.<br />

1-1 Survey<br />

1<br />

1 Languages<br />

• English<br />

• French<br />

• German<br />

• Italian<br />

• Spanish<br />

2 Powerful Functions<br />

• Automatic cooling/heating changeover<br />

• Heating optimization<br />

• Temperature limit<br />

• Yearly schedule<br />

• Power proportional distribution (optional)<br />

• Fire emergency stop control<br />

• Flexible timer functionality (several schedules up to a full year)<br />

• Flexible grouping in zones<br />

• History <strong>data</strong><br />

• Password security (system set-up)<br />

3 Cost Performance<br />

• Labour saving<br />

• Easy installation<br />

• Compact design: limited installation space<br />

• Overall energy saving<br />

4 Simple Operation<br />

• User friendly full colour LCD<br />

• Touch panel<br />

• Icon display<br />

5 Connectable to<br />

• VRV<br />

• HRV<br />

• Sky Air (via interface adapter)<br />

• Split (via interface adapter)<br />

1-2 New functions<br />

1 AUTOMATIC COOLING / HEATING CHANGEOVER<br />

Maintains optimum room temperature by automatically selecting cooling or heating mode according to room temperature for locations<br />

subject to large temperature differences between night and day.<br />

2 TEMPERATURE LIMIT<br />

Automatically starts and stops the air conditioner to prevent temperatures in unoccupied rooms from rising or falling too far, e.g.<br />

- prevents overheating of equipment and formation of condensation in temperature controlled equipment in unoccupied rooms<br />

- also assists in preserving heat in entire buildings by preventing unoccupied rooms from reaching extreme night time temperatures.<br />

3 HEATING OPTIMIZATION<br />

Starts/stops the air conditioner during heating mode, depending on room and set temperatures to prevent the temperature from rising.<br />

2<br />

• Systems • Control Systems


•<br />

2 System Overview<br />

This intelligent Touch Controller is capable of controlling/monitoring up to 64 groups of indoor units<br />

(max. 128 indoor units) (hereafter "groups").<br />

The main functions of the intelligent Touch Controller include:<br />

1 Collective starting/stopping of operation of the indoor units connected to the intelligent Touch Controller.<br />

2 Starting/stopping of operation, temperature setting, switching between temperature control modes and enabling/<br />

disabling of operation with the hand-held remote control by zone or group.<br />

3 Scheduling by zone or group.<br />

4 Monitoring of the operation status by zone or group.<br />

2<br />

5 Display of the air conditioner operation history.<br />

6 Compulsory contact stop input from the central monitoring panel (non-voltage, normally-open contact).<br />

7 Power distribution of the air conditioners. (With the optional DCS002A1)<br />

A group of indoor units includes:<br />

1 One indoor unit without a remote control.<br />

Indoor unit<br />

No remote control<br />

2 One indoor unit controlled with one or two remote controls.<br />

Remote control<br />

or<br />

Remote control<br />

3 Up to 16 indoor units controlled with one or two remote controls.<br />

Remote control<br />

Up to 16 units<br />

Two remote controls<br />

Up to 16 units<br />

A zone includes 1 or more groups of indoor units<br />

* Zone control with the intelligent Touch Controller<br />

* Zone control, which allows collective settings for more than one group, is available with the intelligent Touch<br />

Controller, which facilitates the setting operations<br />

Zone 1<br />

Zone 2 Zone 3 Zone 4<br />

intelligent Touch Controller<br />

Zone 5<br />

• One setting makes the same setting for all of the units in one zone.<br />

• Groups can be zoned at will with the intelligent Touch Controller.<br />

• One group can be attributed to more than one zone.<br />

• Systems • Control Systems 3


•<br />

3 System Image<br />

3-1 Double intelligent touch Controllers<br />

Using two intelligent Touch Controllers allows central control of indoor units from different places.<br />

Outdoor unit<br />

Outdoor unit<br />

In-Out Out-Out<br />

In-Out Out-Out<br />

F1, F2 F1, F2<br />

F1, F2 F1, F2<br />

3<br />

F1, F2<br />

F1, F2<br />

F1, F2 F1, F2 F1, F2<br />

F1, F2<br />

Remote control<br />

Up to 16<br />

Up to 64 groups<br />

When the optional power distribution function<br />

is used, up to 64 indoor units can be connected.<br />

3-2 Options<br />

Connecting the collective remote adapter allows using the contact for normal and abnormal operation signal and collective start/stop with a contact.<br />

Central monitoring panel<br />

Collective start, stop and<br />

error monitoring with contact<br />

Unification adapter (DCS302A52)<br />

for computerized control<br />

Outdoor unit<br />

In-Out Out-Out<br />

Outdoor unit<br />

In-Out Out-Out<br />

F1, F2 F1, F2<br />

F1, F2 F1, F2<br />

Hand switch<br />

Power<br />

1~100 - 240 VAC Grounding<br />

50/60 Hz<br />

Forced stop command<br />

CN2<br />

L1, L2<br />

F1, F2<br />

F1, F2<br />

Meter x 3<br />

(When the optional power distribution function is used)<br />

F1, F2 F1, F2 F1, F2<br />

Remote control<br />

Up to 16<br />

Up to 64 groups<br />

When the optional power distribution function<br />

is used, up to 64 indoor units can be connected.<br />

4<br />

• Systems • Control Systems


•<br />

4 Part Names and Functions<br />

4-1 Part Names and Functions<br />

4<br />

DCS601B51<br />

PCMCIA Card Slot<br />

Used when using the optional power distribution (DCS002A1)<br />

or updating the intelligent Touch Controller software to a newer<br />

version.<br />

Color LCD with Touch Panel<br />

Provides a display for monitoring and operation.<br />

Be sure to use the touch pen provided for operation.<br />

( The display shows the Monitoring and System Setup screens.)<br />

Touch Pen<br />

Be sure to use the touch pen for operation.<br />

Use caution not to lose the touch pen.<br />

Maintenance Door<br />

Generally not used. Close the door for general use.<br />

Use the door when adjusting the contrast of the LCD or<br />

luminance of the backlight.<br />

NOTES<br />

1 Be sure to use the touch pen for operation on the touch panel of the intelligent Touch Controller.<br />

2 Operating with an object other than the touch pen provided may cause damage and failure.<br />

• Systems • Control Systems 5


•<br />

4 Part Names and Functions<br />

4-2 Terminals on the Back of intelligent touch Controller<br />

Use these ports for modem communication when using the<br />

AIRNET Service.<br />

4<br />

232C-1 232C-2 CN2<br />

Ethernet COM Dil Pi3 COM Pi2 Pi1 F2 F1 LON L2 L1<br />

Connect the collective remote control adapter to this connector<br />

for "collective start of operation," "collective stop of operation"<br />

or "error monitoring" remotely with a contact signal.<br />

This port is not used with this model.<br />

This port is not used with this model.<br />

Connect a non-voltage contact for collective stopping of<br />

operation with a contact signal.<br />

Terminals for communication with air conditioning system.<br />

Terminal for the grounding wire.<br />

Connect a watt-hour meter when using the optional power<br />

distribution function software (DCS002A1).<br />

Terminals for the power supply. Connect single-phase power of<br />

100 to 240 VAC, 50/60 Hz.<br />

6<br />

• Systems • Control Systems


•<br />

5 Part Names on the Monitoring Screen and the Functions<br />

Contents of the List Currently Displayed<br />

• When Group List is displayed<br />

"Zone: Zone Name"<br />

• When Zone List is displayed<br />

"Zone List"<br />

Zone/Group Name<br />

Set the names in the Group Registration or Zone<br />

Registration in the System Setup Mode.<br />

Display Mode Selection<br />

Select between Zone and Group.<br />

Display Type Selection<br />

Select the type between Icon and List.<br />

The example below shows the Icon Display.<br />

For List Display, see pages 8 .<br />

Display for Collective Monitoring of Air<br />

Conditioners Connected to intelligent Touch Controller<br />

When operation is normal and any air conditioner is in operation:<br />

Red/Normal<br />

When operation is normal and all air conditioners are in stoppage:<br />

Green/Normal<br />

When there is any air conditioner generating an error:<br />

Yellow/Abnormal<br />

When there is any air conditioner with communication error:<br />

Blue/Abnormal<br />

Target of Automatic Control<br />

Displayed when there is any air conditioner with the<br />

registration of scheduled or demand operation in the<br />

zone or in the group.<br />

Monitoring Screen Legend<br />

Pressing the "?" button shows more detailed legend.<br />

Description of Zone/Group<br />

Set the names in the Group Registration or Zone<br />

Registration in the System Setup Mode.<br />

Start All Button<br />

Button to collectively start all the air conditioners<br />

connected to intelligent Touch Controller.<br />

Stop All Button<br />

Button to collectively stop all the air conditioners<br />

connected to intelligent Touch Controller.<br />

Group/Zone Start Button<br />

Button to start operation of the group/zone selected.<br />

5<br />

Button to Switch to the System Setup Mode<br />

Use this button for settings including the time, group,<br />

zone and schedule. B<br />

System Status Display Area<br />

Area for displaying the system status<br />

(compulsory stop, etc.).<br />

Filter/Element Sign<br />

Displayed when there is any air conditioner showing a<br />

filter or element sign in the zone or the group.<br />

Information on Zone/Group Currently Displayed<br />

Generally, the temperature setting and the operation mode are<br />

displayed. If any error occurs in the air conditioner, the error<br />

code is displayed.<br />

Zone/Group Currently Displayed<br />

The name of the zone/group currently selected is<br />

highlighted.<br />

Scroll Bars<br />

Use the bars to monitor any area of the group/zone list<br />

not currently shown.<br />

Sliding the bars up/down and left/right changes the<br />

range monitored.<br />

Group/Zone Stop Button<br />

Button to stop operation of the group/zone selected.<br />

Group/Zone Set/Prop Button<br />

Makes detailed settings (temperature setting,<br />

temperature control mode, etc.) and display of the<br />

group/zone selected.<br />

Current Time Display<br />

Shows the current date and time.<br />

NOTE<br />

1 Groups can be visualised as icon or can be shown as a list<br />

• Systems • Control Systems 7


•<br />

6 Specifications<br />

6<br />

Intelligent Touch Controller (1*)<br />

DCS601B51<br />

POWER SUPPLY<br />

externally supplied AC100V-240V, 50/60Hz<br />

CONDITION OF INSTALLATION METHOD FOR USE<br />

JIS4 switchbox embedded in indoor wall<br />

OPERATING CONDITION Surrounding temperature 0°C - 40°C<br />

Humidity<br />

less than 85 % RH (if no condensation)<br />

DIMENSIONS PANEL HxWxD mm 147x230x40<br />

LCD PANEL Size 5.7 inches<br />

Nr. of dots<br />

QVGA 320x240<br />

Nr. of colors<br />

4,096 colors<br />

MAXIMUM NUMBER OF INDOOR UNITS 64 (128)<br />

MAXIMUM NUMBER OF OUTDOOR UNITS 10<br />

PC & DISPLAY<br />

built-in<br />

INPUT Touch panel 10 bit encoded analog input<br />

COMMUNICATION FUNCTIONS DIII-NET 1 line of air conditioner equipment for communication use<br />

Ethernet for servicing x 1<br />

modem x 1<br />

INPUT TERMINALS Digital input compulsory shutdown input x 1<br />

Pulse input power measuring pulse input x 3<br />

OVERSEAS CERTIFICATION Safety of information Technology Equipment IEC60730<br />

Interference (EMC)<br />

CISPR22, class-B, EN50082-1<br />

PROJECT DATA & ENGINEERING<br />

Configuration and engineering for each project are necessary.<br />

For further details, please consult with Daikin distributor and dealers<br />

NOTE<br />

1 Service and commissioning is offered by your <strong>technical</strong> service department<br />

7 Accessories<br />

Item<br />

Comments<br />

SOFTWARE DCS002B51 Power Proportional Distribution (PPD)<br />

INSTALLATION BOX KJB411A For wall mounted installation<br />

TOUCH-PEN 1264009 Spare part n° of Touch-Pen for Intelligent Touch Controller<br />

INTERFACE ADAPTERS KRP928A2S For connection to Split units<br />

DTA102A52<br />

For connection to R-22/R-407C Sky Air units<br />

DTA112B51<br />

For connection to R-410A Sky Air units<br />

8<br />

• Systems • Control Systems


•<br />

8 Dimensions<br />

Front view<br />

Door for PCMCIA card<br />

When using the optional Power Proportional<br />

Distribution Card (DCS002A51), open the door<br />

and insert the PCMCIA memory card.<br />

Back view<br />

DCS601B51<br />

Port shown by oblique lines is<br />

to be embedded in the wall<br />

or the control panel<br />

Access door<br />

Touch pen for operating the touch panel<br />

( attached to the intelligent Touch Controller )<br />

8<br />

This connector cannot be<br />

used with this unit.<br />

Ethernet<br />

Lon<br />

Item Nr Color<br />

1 KA Ivory white<br />

Ki Gray<br />

KU N-2. 0 (Black)<br />

KE SP-536 (Orange metallic)<br />

KO N-6. 0 (Gray)<br />

NOTES<br />

1 Rated electrical conditions<br />

• Rated voltage and frequency: Single phase AC100-240,50/60Hz<br />

• Rated power Maximum 10W<br />

2 Conditions for use<br />

• Power supply fluctuation: ±10% of the rated value<br />

• Ambient temperature: 0~+40°C<br />

• Ambient humidity: 10~ 90% (Sweating is not acceptable)<br />

3 Mass: 1.2 Kg<br />

3D031659<br />

• Systems • Control Systems 9


•<br />

9 System Wiring<br />

(Do not fail to use a round crimp terminal with reinforcing sleeve for safety wiring connection to the intelligent Touch Controller.)<br />

Wiring outline<br />

Outdoor unit<br />

Switch<br />

Fuse (10A)<br />

9<br />

Power supply<br />

1-100V~240V<br />

50/60Hz<br />

Grounding work<br />

Force stop command<br />

Up to 16 units maximum<br />

Measuring meter * 3<br />

Up to 64 groups maximum<br />

(Where Power Proportional Distribution Card as option is used)<br />

( The number of connectable indoor units is up to 64 units maximum,<br />

where the Power Proportional Distribution Card as option is used.)<br />

System wiring<br />

Outdoor unit<br />

Outdoor unit<br />

intelligent Touch Controller back<br />

In-Out Out-Out<br />

F1, F2 F1, F2<br />

In-Out Out-Out<br />

F1, F2 F1, F2<br />

Indoor unit<br />

to other outdoor unit<br />

Indoor unit<br />

Force-stop input<br />

*1<br />

Measuring meter x 3 *2 (Where<br />

Power proportional distribution<br />

Card as option is used)<br />

Grounding<br />

work<br />

Power supply<br />

1-100V~240V<br />

50/60Hz<br />

Indoor unit Indoor unit Indoor unit<br />

Unification adapter for computerized control<br />

(DCS302A52)<br />

Connector for connection<br />

(For the detail, see installation manual of the<br />

Unification adapter for computerized control)<br />

*1: When FORCE-STOP INPUT is kept ON, the indoor units connected are unable to be operated because they are force-stopped.<br />

- Use a contact which can guarantee minimum application load DC16V and 10mA.<br />

- Use an instantaneous contact of 200msec or more in current feed time, where required.<br />

*2: The measuring meters to be connected must meet the requirements specified below.<br />

- To be a measuring meter with pulse oscillator. (pulse/kWh)<br />

- Pulse band of 100msec or more<br />

- Measuring meter which uses mercury relay or semiconductor relay for pulse output and outputs pulses from non-voltage contact.<br />

Caution 1: Terminals COM are inter-connected. Connecting to either one is allowed, but the number of cables connectable to one terminal<br />

is limited to 2 pieces.<br />

Caution 2: Don't connect the power cable to this terminal block and F1, F2 terminal blocks. Wrong connection to these terminal blocks<br />

could result in damage and burning of the centralized control devices and of the electric parts of the indoor and outdoor units.<br />

This is very hazardous. Check each wired cable once more before turning ON the power switch.<br />

Wiring specification<br />

Power cable wiring<br />

Fuse<br />

Communication wiring for indoor unit<br />

and outdoor unit<br />

(*1)<br />

Wiring for force stop input<br />

(*2)<br />

Meter wiring for power distribution (option)<br />

(*3)<br />

1.25mm 2<br />

10A<br />

0.75 - 1.25 mm 2 vinyl cord or cable with sheath (2 wire)<br />

---Up to 1,000 m maximum<br />

(Wiring length -- up to 2,000 m maximum)<br />

(When shield cable is used, the wiring length is available up to 1,500m.)<br />

0.75 - 1.25 mm 2 vinyl cord or cable with sheath (2 wire) -- up to 150m maximum<br />

0.75 - 1.25 mm 2 vinyl cord or cable with sheath (2 wire) -- up to 150m maximum<br />

NOTE<br />

1 The above wiring *1 - *3 are for the communication wiring for control use. Don't clamp these cables together with high voltage cables. Failure to<br />

observe this instruction would cause control error.<br />

3D031660<br />

10<br />

• Systems • Control Systems


•<br />

10 Power Proportional Distribution Card<br />

10-1 Function and Outline<br />

Power Proportional Distribution Card, in combination with an existing intelligent Touch Controller, enables to proportionally calculate and display<br />

electricity amount used by air conditioner per indoor unit.<br />

10-1-1 Main Functions<br />

NEW<br />

NEW<br />

• 13 months <strong>data</strong> storage possible<br />

• Data available per hour per indoor unit<br />

• Power proportional distribution may be calculated for 64 indoor units at maximum.<br />

• Power proportion distribution results <strong>data</strong> may be saved into a PCMCIA card.<br />

Data is saved CSV format generally applied to personal computers, so bills may be issued by use of a general purpose table calculation<br />

software package in easy manners.<br />

(A personal computer and a general purpose table calculation software package may be available separately.)<br />

• There are 2 kinds of power proportional distribution:<br />

10<br />

10-1-2 Precautions<br />

Normal type: Power proportional distribution is carried out by VRV style calculation.<br />

Power proportional distribution is carried out per indoor unit.<br />

This system calculates electricity consumptions by size of indoor units, run time, expansion vales open gap, suction rate and the number of pulses from<br />

the power meters installed at the Outdoor Units.<br />

This method is not calculated by direct measurement alone.<br />

Electric power meter<br />

(with pulse output)<br />

123 123 123<br />

Power proportional distribution pulse.<br />

Maximum number of inputs -3.<br />

DIII-NETx1<br />

Outdoor unit<br />

DCS601B51<br />

PCMCIA card slot<br />

Indoor unit<br />

ÇcÇbÇr ÇOÇOÇQÇ`ÇTÇP<br />

DAIKIN INDUSTRIES. LTD.<br />

Power Proportional<br />

Distribution Card<br />

Bills may be issued by use of a general purpose table<br />

calculation software package in easy manners.<br />

64 units at maximum<br />

General purpose<br />

software<br />

Bills<br />

A personal computer and a general purpose table calculation software package may be available separately.<br />

• Systems • Control Systems 11


•<br />

10 Power Proportional Distribution Card<br />

10-2 Preparation<br />

10-2-1 Checking Attachments<br />

Power Proportional Distribution Card (DCS002B51) includes the following attachments.<br />

CBR000'TP<br />

10<br />

DAIKIN INDUSTRIES. LTD.<br />

Instruction Manual<br />

10-2-2 How to Connect<br />

To activate the power proportional distribution function, it is necessary to set the<br />

program by use of the attached PCMCIA card and carry out a trial operation.<br />

Before use, consult your supplier.<br />

12<br />

• Systems • Control Systems


•<br />

10 Power Proportional Distribution Card<br />

10-3 File Format<br />

When Power Proportional Distribution Report is saved, a zone information file and an electric power information file are created.<br />

10-3-1 Zone information file<br />

This contains zone name and information of air conditioners in the zone.<br />

(1) File name : ZONE.CSV<br />

(2) File format:<br />

10<br />

(Example)<br />

zone ID, Name<br />

0,all<br />

1, 'Z-000<br />

2, 'Z-001<br />

3, 'Z-002<br />

Index<br />

Zone ID, zone name<br />

zone ID, AC No.<br />

0, 0<br />

0, 1<br />

1, 2<br />

1, 3<br />

One line space<br />

Zone ID, air conditioner number<br />

10-3-2 Electric power information file<br />

This file contains Power Proportional Distribution Report and information of air conditioners.<br />

(1) File name : 332 - MMDD - N.CSV<br />

Serial number<br />

Month and date of calculation completion<br />

Year, month and date of calculation start<br />

Year, month and date of calculation start<br />

(2) File format :<br />

(Example)<br />

Index<br />

Start day, number of days, air conditioner type (0 : normal type), electric power amount not proportionally distributed, period designation type<br />

(0 : period designation, 1 : month designation)<br />

20010511, 30, 0, 0, 0<br />

One line space<br />

Air conditioner number, indoor unit number, horse power code, electricity use amount, electric power amount at stop.<br />

1, '1-01, fb, 0, 8<br />

2, '1-03, 38, 0, 0, 13, 0<br />

• Systems • Control Systems 13


2<br />

Systems<br />

ISO14001 assures an effective environmental<br />

management system in order to help protect<br />

human health and the environment from the potential<br />

impact of our activities, products and services and to<br />

assist in maintaining and improving the quality of<br />

the environment.<br />

Daikin units comply with the European<br />

regulations that guarantee the safety of<br />

the product.<br />

Daikin Europe N.V. is approved by LRQA for its Quality<br />

Management System in accordance with the ISO9001<br />

standard. ISO9001 pertains to quality assurance regarding<br />

design, development, manufacturing as well as to services<br />

related to the product.<br />

VRV products are not within the scope<br />

of the Eurovent certification programme.<br />

Specifications are subject to change without prior notice<br />

Zandvoordestraat 300<br />

B-8400 Ostend - Belgium<br />

Internet: http://www.daikineurope.com<br />

EEDE03-2/3A • 08/2003<br />

Prepared in Belgium by Vanmelle