03.06.2015 Views

Pump Test - Malaysian Water Association.

Pump Test - Malaysian Water Association.

Pump Test - Malaysian Water Association.

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>Pump</strong> <strong>Test</strong>ing Requirement<br />

ISO 9906:2012<br />

Rotodynamic pumps -- Hydraulic<br />

performance acceptance tests -- Grades<br />

1, 2 and 3


<strong>Pump</strong> <strong>Test</strong>ing Requirement<br />

• ISO 9906:2012 specifies hydraulic performance tests for customers'<br />

acceptance of rotodynamic pumps (centrifugal, mixed flow and<br />

axial pumps). It is intended to be used for pump acceptance testing<br />

at pump test facilities, such as manufacturers' pump test facilities or<br />

laboratories. ISO 9906:2012 can be applied to pumps of any size<br />

and to any pumped liquids which behave as clean, cold water.<br />

• It specifies three levels of acceptance:<br />

• grades 1B, 1E and 1U with tighter tolerance;<br />

• grades 2B and 2U with broader tolerance;<br />

• grade 3B with even broader tolerance.<br />

• It applies either to a pump itself without any fittings or to a<br />

combination of a pump associated with all or part of its upstream<br />

and/or downstream fittings.


<strong>Pump</strong> <strong>Test</strong>ing Requirement<br />

Main Objective<br />

Confirm pump performance parameters:<br />

• Capacity<br />

• Head<br />

• Power<br />

• Efficiency<br />

• NPSH


<strong>Pump</strong> <strong>Test</strong>ing Requirement<br />

Others<br />

Confirm pump performance parameters:<br />

• Temperature rise<br />

• Noise<br />

• Dimension<br />

• Material<br />

• Protection coating


<strong>Pump</strong> <strong>Test</strong>ing Requirement<br />

Consideration<br />

Confirm pump performance parameters:<br />

• <strong>Water</strong> Temperature<br />

• Speed<br />

• Power<br />

• Efficiency<br />

• NPSH


<strong>Pump</strong> <strong>Test</strong>ing Requirement<br />

Arrangement


<strong>Pump</strong> <strong>Test</strong>ing Requirement<br />

Item<br />

Particulars Unit 1 2 3<br />

No.<br />

1. Quantity of water delivered against m 3 /hr<br />

Total Head by each pump<br />

2. Total Dynamic Head<br />

m<br />

3. <strong>Water</strong> Power (base on item 1 & 2) kW<br />

4. Maximum Power input for Motor kW<br />

5. Overall Efficiency of <strong>Pump</strong> and Motor %<br />

6. <strong>Pump</strong> Speed rpm<br />

7. NPSH m


<strong>Pump</strong> <strong>Test</strong>ing Requirement<br />

Computation<br />

Flow meter 1


<strong>Pump</strong> <strong>Test</strong>ing Requirement<br />

Item<br />

Particulars Unit 1 2 3<br />

No.<br />

1. Quantity of water delivered against m 3 /hr<br />

Total Head by each pump<br />

1<br />

2. Total Dynamic Head<br />

m<br />

3. <strong>Water</strong> Power (base on item 1 & 2) kW<br />

4. Maximum Power input for Motor kW<br />

5. Overall Efficiency of <strong>Pump</strong> and Motor %<br />

6. <strong>Pump</strong> Speed rpm<br />

7. NPSH m


<strong>Pump</strong> <strong>Test</strong>ing Requirement<br />

Pressure<br />

gauge P1<br />

Computation<br />

Pressure<br />

gauge P2<br />

2<br />

= P2 – P1 + (V2 2 – V1 2 /2g)


<strong>Pump</strong> <strong>Test</strong>ing Requirement<br />

Item<br />

Particulars Unit 1 2 3<br />

No.<br />

1. Quantity of water delivered against m 3 /hr<br />

Total Head by each pump<br />

1<br />

2. Total Dynamic Head<br />

m 2<br />

3. <strong>Water</strong> Power (base on item 1 & 2) kW<br />

4. Maximum Power input for Motor kW<br />

5. Overall Efficiency of <strong>Pump</strong> and Motor %<br />

6. <strong>Pump</strong> Speed rpm<br />

7. NPSH m


<strong>Pump</strong> <strong>Test</strong>ing Requirement<br />

Computation<br />

kW, (after power<br />

factor) 4<br />

Speed<br />

5<br />

3<br />

<strong>Water</strong> Power = 1 x 2 x 9.81


<strong>Pump</strong> <strong>Test</strong>ing Requirement<br />

Item<br />

Particulars Unit 1 2 3<br />

3<br />

No.<br />

1. Quantity of water delivered against m 3 /hr<br />

1<br />

Total Head by each pump<br />

2<br />

2. Total Dynamic Head<br />

m<br />

3. <strong>Water</strong> Power (base on item 1 & 2) kW<br />

3<br />

4. Maximum Power input for Motor kW 4<br />

5. Overall Efficiency of <strong>Pump</strong> and Motor %<br />

6. <strong>Pump</strong> Speed rpm<br />

7. NPSH m<br />

5<br />

4<br />

X 100

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!