Wöhler A 500 Combustion&Emmissions Analyzer<br />

Order No.<br />

Measuring Instruments<br />

O 2<br />

A 500 Combustion & Emmisions Analyzer, Standard Equipment<br />

options:<br />

CO<br />

32,000<br />

NO<br />

CO 2<br />

CO NO2 SO2 T FlueGas<br />

T T Draft<br />

Taup<br />

2,000<br />

Air<br />

NO<br />

2,000<br />

NO2<br />

SO2<br />

DP<br />

40 hPA<br />

2000 Pa<br />

l<br />

A 500 Standard Equipment with 1.7 m hose and probe for measuring:<br />

Oxygen (O 2<br />

), Carbon Dioxide (CO 2<br />

), Carbon monoxide 4,000 ppm (CO), Carbon<br />

monoxide referred to O2 (COref), Stack Temperature (T S<br />

), Ambient Temperature<br />

(T A<br />

), Draft (P), Dewpoint (DP), Losses (qA), Efficiency (η), Excess Air (l).<br />

A 500 Combustion & Emissions Analyzer Standard Equipment<br />

comes with:<br />

A 500 Combustion & Emmissions Analyzer with IrDA-interface, customer memory,<br />

4 type AA rechargeable NiMH batteries, quick charger, gas probe 295 mm long and<br />

cable-hose 1.7 m length, combustion air temperature probe (plug-form),<br />

condensate cleanout brush, 25 cotton filters for water trap, 1 soot filter, 1 water-stop filter.<br />

h<br />

qA<br />

IrDA<br />

C<br />

9051 J<br />

A 500 Combustion & Emissions Analyzer, Standard Equipment<br />

+ CO: 0 - 32,000 ppm<br />

A 500 Combustion & Emissions Analyzer, Standard Equipment<br />

+ CO: 0 - 32,000 ppm<br />

+ NO: 0 - 2,000 ppm<br />

+ NO2<br />

A 500 Combustion & Emissions Analyzer, Standard Equipment<br />

+ SO2<br />

9061 J<br />

9071 J<br />

9081 J<br />

A 500 Combustion & Emissions Analyzer, Advanced Equipment<br />

+ NO: 0 - 2,000 ppm<br />

+ SO2<br />

9091 J<br />

A 500 Advanced Set, Plastic Case<br />

Advantages:<br />

• compact, durable system case<br />

• foam insert with space for spare parts and tools<br />

5036 J<br />

Comes with:<br />

A 500 Combustion & Emissions Analyzer standard set with 1.7 m cable hose, TD 600 fast<br />

infrared thermal printer with 6 rolls of paper and batteries, standard cone, coarse filter (5<br />

pieces), water-stop filter (3 pieces), plastic case<br />

A 500 Professional Set, Alu Framed Leather Case<br />

Advantages:<br />

• durable, upright quality craftsman leather case<br />

• the A 500 is placed diagonal on a metal plate, perfect for the operation of the<br />

instrument inside the case<br />

Comes with:<br />

A 500 Combustion & Emissions Analyzer standard set with 1.7 m cable hose, multi-hole<br />

probe 60/160, combustion air temperature probe 280 mm with 1.6 m cable with magnetic<br />

holder, TD 600 fast infrared thermal printer with 6 rolls of paper and batteries, RP 72 soot test<br />

pump (set), PTFE-cone, swivel probe holder, standard cone, coarse filter (5 pieces), water-stop<br />

filter (3 pieces), aluminium framed leather case<br />

5060 J<br />