Wöhler Soot Test Computer<br />

Order No.<br />

Measuring Instruments<br />

RZ 95 Soot Test Computer<br />

TÜV approved<br />

Specifications:<br />

Reflectance values:<br />

Measuring principle:<br />

Optical Reflection<br />

measurement<br />

Measurement range: 0.000 - 0.999<br />

reflectance<br />

Mass flow of flue-gas:<br />

Measuring principle: Hot-film<br />

anemometer<br />

Measurement range: 0 - 5 NL/min.<br />

Linearity error: 3 % of actual value<br />

Calculated values:<br />

Flue-gas volume normalized:<br />

1.63 ± 0.070 NL,<br />

Reffered to 990 hPa,<br />

20°C<br />

Smoke spot no: from 0.0 to 9.9<br />

Weight:<br />

1,650 g with probe<br />

Application:<br />

The RZ 95 Smoke Test Computer is ideally<br />

suitable for precise determination of<br />

smoke spot number with a resolution<br />

of 0.1.<br />

Function:<br />

Advantages:<br />

• precise handheld instrument that samples<br />

the flue-gas volume in a regulated manner<br />

and evaluates the smoke spot number<br />

with a resolution of 0.1<br />

• simplifies and objectivises the well-proven<br />

method of determining the smoke spot<br />

number<br />

• with commercially available filter paper<br />

In max. 60 se<br />

of air pressure and temperature. The caused soot spot leads to a change of the optical reflecting intensity on the filter paper.<br />

This is de<br />

uses commercial<br />

with one filter paper. Apart from the single results the average smoke test number is calculated.<br />

Standard Equipment<br />

Accessories RZ 95 Test Paper 9456 G<br />

Wöhler HD 2000 Heating Diagnosis<br />

Function:<br />

RZ 95 hand-held instrument with optoelectronic measuring head, sampling probe 200 mm,<br />

threaded cone, water trap, charger, leather bag with carrying strap, test paper,<br />

probe brush 6 mm Ø, bag of short cotton filter rolls, bag of long cotton filter rolls,<br />

bag of porosilicate, bag of filter papers 1,800 pieces<br />

Porosilicate, gas drying agent, 200 g<br />

Charger for RZ 95<br />

Filter paper, Cotton filter rolls long and short, see page 13<br />

Advantages:<br />

• Acoustic and visual service indication<br />

for service requirements of oil burners<br />

• Determination of customer-specific<br />

consumption data<br />

• Determination of level of annual usage<br />

• Data transfer in the IrDA mode<br />

• Easiest mounting using magnetic<br />

holder<br />

• Maintenance-free<br />

Flue-gas temperature:<br />

Range: 0...500 °C<br />

Accuracy: ± 3 °C<br />

Display:<br />

Flue-gas temperature, operating and burner<br />

operating time according to VDI 3808, total<br />

hours<br />

Data logger:<br />

Memory for more than 3.5 years<br />

Power supply:<br />

2 x 1.5 V monocells for max. 3.5 years<br />

The HD 2000<br />

temperatur -<br />

in<br />

maintenance takes place via acoustic and visual indication.<br />

9200 O<br />

9457 D<br />

51878 J<br />

HD 2000 Heating Diagnostic, with probe, cone and batteries<br />

HD 2000 Software, (free download from our website)<br />

7500 A<br />

16<br />