International Catalogue 2005/2006 - MRC
International Catalogue 2005/2006 - MRC
International Catalogue 2005/2006 - MRC
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Wöhler Soot Test Computer<br />
Order No.<br />
Measuring Instruments<br />
RZ 95 Soot Test Computer<br />
TÜV approved<br />
Specifications:<br />
Reflectance values:<br />
Measuring principle:<br />
Optical Reflection<br />
measurement<br />
Measurement range: 0.000 - 0.999<br />
reflectance<br />
Mass flow of flue-gas:<br />
Measuring principle: Hot-film<br />
anemometer<br />
Measurement range: 0 - 5 NL/min.<br />
Linearity error: 3 % of actual value<br />
Calculated values:<br />
Flue-gas volume normalized:<br />
1.63 ± 0.070 NL,<br />
Reffered to 990 hPa,<br />
20°C<br />
Smoke spot no: from 0.0 to 9.9<br />
Weight:<br />
1,650 g with probe<br />
Application:<br />
The RZ 95 Smoke Test Computer is ideally<br />
suitable for precise determination of<br />
smoke spot number with a resolution<br />
of 0.1.<br />
Function:<br />
Advantages:<br />
• precise handheld instrument that samples<br />
the flue-gas volume in a regulated manner<br />
and evaluates the smoke spot number<br />
with a resolution of 0.1<br />
• simplifies and objectivises the well-proven<br />
method of determining the smoke spot<br />
number<br />
• with commercially available filter paper<br />
In max. 60 se<br />
of air pressure and temperature. The caused soot spot leads to a change of the optical reflecting intensity on the filter paper.<br />
This is de<br />
uses commercial<br />
with one filter paper. Apart from the single results the average smoke test number is calculated.<br />
Standard Equipment<br />
Accessories RZ 95 Test Paper 9456 G<br />
Wöhler HD 2000 Heating Diagnosis<br />
Function:<br />
RZ 95 hand-held instrument with optoelectronic measuring head, sampling probe 200 mm,<br />
threaded cone, water trap, charger, leather bag with carrying strap, test paper,<br />
probe brush 6 mm Ø, bag of short cotton filter rolls, bag of long cotton filter rolls,<br />
bag of porosilicate, bag of filter papers 1,800 pieces<br />
Porosilicate, gas drying agent, 200 g<br />
Charger for RZ 95<br />
Filter paper, Cotton filter rolls long and short, see page 13<br />
Advantages:<br />
• Acoustic and visual service indication<br />
for service requirements of oil burners<br />
• Determination of customer-specific<br />
consumption data<br />
• Determination of level of annual usage<br />
• Data transfer in the IrDA mode<br />
• Easiest mounting using magnetic<br />
holder<br />
• Maintenance-free<br />
Flue-gas temperature:<br />
Range: 0...500 °C<br />
Accuracy: ± 3 °C<br />
Display:<br />
Flue-gas temperature, operating and burner<br />
operating time according to VDI 3808, total<br />
hours<br />
Data logger:<br />
Memory for more than 3.5 years<br />
Power supply:<br />
2 x 1.5 V monocells for max. 3.5 years<br />
The HD 2000<br />
temperatur -<br />
in<br />
maintenance takes place via acoustic and visual indication.<br />
9200 O<br />
9457 D<br />
51878 J<br />
HD 2000 Heating Diagnostic, with probe, cone and batteries<br />
HD 2000 Software, (free download from our website)<br />
7500 A<br />
16<br />
Internet: http://www.woehler.com