17.11.2012 Views

1.Titel 1.12G6..._e.psd - Petrick-GmbH

1.Titel 1.12G6..._e.psd - Petrick-GmbH

1.Titel 1.12G6..._e.psd - Petrick-GmbH

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Tube Current (mA)<br />

3,5<br />

3,0<br />

2,5<br />

2,0<br />

1,5<br />

1,0<br />

0,5<br />

Design changes in the sense of the development reservations.<br />

<strong>Petrick</strong><br />

Technical Specification<br />

Microfocus X-ray tube P030.40.20G…* Z.Nr.: 1.14G6…*<br />

1. Geometry: Drawing for assembling<br />

2. Radiation field: Target angle 20°<br />

3. Inherent filtration: 0,76...1,04 mm Al-equivalent<br />

4. Type of operating: DC<br />

5. Focal spot:<br />

FILAMENT CHARACTERISTICS 50 kV<br />

0,0<br />

0,0<br />

1,00 1,10 1,20 1,30 1,40<br />

Filament Current (A)<br />

at U tube = 50 kV, I tube = 1 mA<br />

6. Heating characteristics: U tube = 80 kV, I tube = 0,7 mA<br />

7. operating voltage: 4…80 kV<br />

8. max.filament current: see diagram<br />

9. max.rating: 1,0 mA<br />

10. Exposure time: Duration-drive<br />

11. Heat capacity: 3900 Joule<br />

U H = 2,0...3,5 V; I H = 1,18...1,31 A<br />

12. max.power continuesly: 50 W<br />

(higher power on request)<br />

13. Anode cooling: Convection cooling<br />

14. Insulation medium: Oil<br />

30…55 µm<br />

Heating current at power supply to be limited 50 mA above nominal operating<br />

current. To ensure proper operating parameters, we recommend to verify<br />

current indicator of your power supply.<br />

15. Anode material * : Tungsten, Molybdenum, Tantalum, Copper, Chrome,<br />

Rhodium, Cobalt (max.15 W)<br />

max. 84,0<br />

3,5<br />

3,0<br />

2,5<br />

2,0<br />

1,5<br />

1,0<br />

0,5<br />

Filament Voltage (V)<br />

Durability (h)<br />

1.000.000<br />

100.000<br />

10.000<br />

1.000<br />

1,16<br />

1,18<br />

Calculated durability<br />

1,20<br />

1,22<br />

1,24<br />

1,26<br />

1,28<br />

1,30<br />

For customer disposal available<br />

with wire or case connections.<br />

1,32<br />

Filament current (A)<br />

35,0 +0,1<br />

X-ray 40° X-ray 40°<br />

-0,1<br />

3,0<br />

Ø 10,0<br />

M 5<br />

Ø 30,0 +1,0<br />

-1,0<br />

heating<br />

1,34<br />

1,36<br />

1,38<br />

1,40<br />

<strong>GmbH</strong><br />

115 years<br />

11 years<br />

13 months<br />

6 weeks<br />

grid control<br />

M 1:1


P030.40.20G...*<br />

Radiation protection<br />

-Emitter can emit harmful X-rays<br />

-There is a danger of implosion<br />

-User is account for personal protection by a housing<br />

<strong>Petrick</strong><br />

X-ray<br />

<strong>GmbH</strong><br />

( * ):<br />

Tungsten<br />

Molybdenum<br />

Tantalum<br />

Cobalt<br />

Copper<br />

Chrome<br />

Mo<br />

Ni<br />

( * )<br />

Cu<br />

FeNiCo<br />

Ni<br />

Glass