<strong>Petrick</strong><br />

<strong>Small</strong> <strong>stationary</strong> <strong>anode</strong> x-<strong>ray</strong> <strong>tube</strong> P800.24GW (1.872W)<br />

70kV IH (A)<br />

70kV UH (V)<br />

50kV IH (A)<br />

50kV UH (V)<br />

20kV IH (A)<br />

20kV UH (V)<br />

Heating I(A)/U(V)<br />

2,80<br />

2,70<br />

2,60<br />

2,50<br />

2,40<br />

2,30<br />

2,20<br />

2,10<br />

2,00<br />

1,90<br />

1,80<br />

1,70<br />

1,60<br />

Technical Specification<br />

1. Geometry: Drawing for assembling<br />

2. Radiation field: Target angle 12°<br />

3. Inherent filtration: 0,76...1,04 mm Al-equivalent<br />

4. Type of operating: DC<br />

5. Focal spot: 800 µm<br />

6. Filament heating: U H max = 2,75 V<br />

7. max.operating voltage: 70 kV<br />

I H max = 2,00 A<br />

8. max.rating: 4,0 mA<br />

9. Heat capacity: 3900 Joule<br />

10. Power continuesly: 50 W<br />

11. Anode cooling: Convection cooling<br />

12. Insulation medium: Oil<br />

13. Anode material: Tungsten<br />

Heating characteristic 20...70 kV<br />

above endurance reduction<br />

above endurance reduction<br />

1,50<br />

1,00 2,00 3,00 4,00<br />

Tube current (mA)<br />

Heating<br />

voltage<br />

tuogh max. 50 W<br />

continuous rating<br />

Heating current<br />

max. 80,0<br />

For customer disposal available<br />

with wire or case connections<br />

3,0 +0,5<br />

-0,5<br />

<strong>GmbH</strong><br />

M 5<br />

connected with<br />

Wehnelt cylinder<br />

Focal spot M 10 : 1<br />

getter<br />

Ø 30,00 +0,25<br />

-0,25<br />

Ø 10,0<br />

heating<br />

35,0<br />

x-<strong>ray</strong><br />

x-<strong>ray</strong><br />

M 1:1


P800.24GW<br />

Radiation protection<br />

-Emitter can emit harmful X-<strong>ray</strong>s<br />

-There is a danger of implosion<br />

-User is account for personal protection by a housing<br />

<strong>Petrick</strong><br />

X-<strong>ray</strong><br />

<strong>GmbH</strong><br />

Mo<br />

Ni<br />

W<br />

Cu<br />

FeNiCo<br />

Ni<br />

Glass