BIOTECTOR ANALYTICAL SYSTEMS LTD<br />

<strong>BioTector</strong> <strong>Series</strong> 4 <strong>TOC</strong> <strong>Analyzer</strong><br />

<strong>Technical</strong> <strong>Specifications</strong><br />

GENERAL TECHNICAL DATA<br />

Enclosure:<br />

Fibreglass Reinforced Polyester<br />

Dimensions (HxWxD): 1250 x 750 x 320mm<br />

Weight:<br />

90 kg<br />

Power Consumption: 300 W<br />

Mains Connection: 230V or 115V AC<br />

SPECIFICATION SHEET<br />

PAGE 1<br />

FEATURES IN DETAIL<br />

Display:<br />

Data Storage:<br />

Operation:<br />

Language Options:<br />

High Contrast 40 Character x 16 Line Backlit LCD with CFL<br />

Backlight<br />

Previous 5000 Reaction Data<br />

Previous 50 Fault Signals<br />

Microcontroller with Membrane Keyboard<br />

English, German, French, Italian, Spanish, Swedish, Norwegian,<br />

Dutch.<br />

INPUT & OUTPUT SIGNALS<br />

Standard Output: 4 - 20mA for <strong>TOC</strong><br />

Digital Output:<br />

2 Potential Free Alarm Contacts, Programmable<br />

1 Potential Free Fault Contact, Programmable<br />

Serial Port:<br />

RS232 Output for Printer or Data Logger<br />

OPTIONAL FEATURES<br />

Output:<br />

Remote Pause Signal:<br />

Industrial Interface:<br />

Valves:<br />

Multi-stream:<br />

Manual Sample:<br />

EExp:<br />

CONSUMABLES<br />

Acid & Base:<br />

HCl Water:<br />

Oxygen:<br />

Service:<br />

TIC, TC, VOC, BOD, COD<br />

Input for Remote Pause<br />

Modbus, Profibus, Ethernet<br />

Automatic Calibration and Sample Line Cleaning<br />

Up to 6 Streams with independent 4-20mA signals<br />

Up to 8 Manual Sample Input Points<br />

Certified and Available on Request<br />

Replacement Frequency - Application Dependant<br />

(Typically 4 - 8 weeks)<br />

for FMI Circulation Pump (10 – 12 weeks)<br />

Option of Integrated Oxygen Generator available<br />

6 Monthly Intervals<br />

<strong>BioTector</strong> Analytical Systems Limited<br />

Raffeen House, Ringaskiddy,<br />

Co. Cork,<br />

Ireland<br />

Tel: +353-21-4374237<br />

Fax: +353-21-4374236<br />

e-mail: info@biotector.com<br />

www.biotector.com


BIOTECTOR ANALYTICAL SYSTEMS LTD<br />

SPECIFICATION SHEET<br />

ANALYSIS PARAMETERS<br />

Principal Operation: Patented Two-Stage Advanced Oxidation Process using<br />

Hydroxyl Radicals.<br />

PAGE 2<br />

Measured Components:<br />

<strong>TOC</strong> (NPOC)<br />

TIC<br />

TC<br />

VOC / POC<br />

True <strong>TOC</strong> (TC – TIC)<br />

After Correlation Tests:<br />

COD<br />

BOD<br />

Principal Operation: Batch Samples<br />

Frequency: <strong>TOC</strong> < 6.5 minutes<br />

Monitoring Ranges: Ultra Low Range 0-5000µg/l (ppb)<br />

Low Range 0-1mg/l to 0-10mg/l (ppm)<br />

Standard Range 0-10mg/l to 0-10,000mg/l<br />

High Range 0-15mg/l to 0-20,000mg/l<br />

Ultra High Range 0-20mg/l to 0-100,000mg/l<br />

Other measuring ranges are available upon request.<br />

Exceedence Tracking:<br />

Records Full Tracking to Maximum Range<br />

REPEATABILITY:<br />

DETECTION LIMIT:<br />

<strong>TOC</strong><br />

<strong>TOC</strong><br />

Ultra Low Range ± 3% or ± 10ppb of the reading 20ppb<br />

Low Range ± 3% or ± 0.2mgC/l of the reading 0.4mgC/l<br />

Standard Range ± 3% or ± 0.3mgC/l of the reading 0.6mgC/l<br />

High Range ± 3% or ± 30mgC/l of the reading 60mgC/l<br />

Ultra High Range ± 3% or ± 300mgC/l of the reading 600mgC/l<br />

Sample Volume: 0.02 - 8.0ml<br />

Particle Size:<br />

Up to 2 mm Ø, soft particulates<br />

Filtration:<br />

Not required<br />

Signal Drift:<br />

< 5% per year<br />

Ambient Temperature: 5 – 40°C<br />

Humidity:<br />

5 - 85%, non-condensing<br />

Chloride Interference:<br />

All Ranges<br />

<strong>TOC</strong><br />

None<br />

<strong>BioTector</strong> Analytical Systems Limited<br />

Raffeen House, Ringaskiddy,<br />

Co. Cork,<br />

Ireland<br />

Tel: +353-21-4374237<br />

Fax: +353-21-4374236<br />

e-mail: info@biotector.com<br />

www.biotector.com


BIOTECTOR ANALYTICAL SYSTEMS LTD<br />

SPECIFICATION SHEET<br />

PAGE 3<br />

APPLICATIONS<br />

• Control of Influent to Waste Treatment Plant<br />

• Monitoring of Final Effluent<br />

• Process Control<br />

• Minimizing Waste from Process Plants<br />

• Cooling Water Monitoring<br />

• Boiler Feed Water Monitoring<br />

• Municipal Waste Treatment Plant Monitoring – Influent & Effluent<br />

• River Water Monitoring<br />

<strong>BioTector</strong> Analytical Systems Limited has a continuous research and development<br />

programme. <strong>Specifications</strong> may therefore be changed without notice. For specification<br />

updates, please contact <strong>BioTector</strong> Analytical Systems.<br />

The <strong>BioTector</strong> <strong>Series</strong> 4 Plus On-Line Organic <strong>Analyzer</strong> comes with up to<br />

12 months warranty against manufacturing errors.<br />

<strong>BioTector</strong> Analytical Systems Limited<br />

Raffeen House, Ringaskiddy,<br />

Co. Cork,<br />

Ireland<br />

Tel: +353-21-4374237<br />

Fax: +353-21-4374236<br />

e-mail: info@biotector.com<br />

www.biotector.com

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!