Design and Areas of Application Nomenclature TVZ VAV terminal box with integrated silencer, for supply air TVA VAV terminal box with integrated silencer, for extract air TVR VAV terminal box with integrated silencer, for supply and extract air 9 TVJ VAV terminal box, casing rectangular TVT VAV controller, casing rectangular, control damper leakage complies with DIN 1946, part 4 TVM VAV dual duct etrminal box ...-D Additional acoustic cladding
Installation 1 Contents Subject Page Safety Instructions 2 Delivery and Storage 3 Transport on Site 3 Reheat Coil Connections 4 Wiring and Tubing Connections 4 Secondary Silencer 4 Installation TVJ/TVT 5 Design changes reserved · All rights reserved · ® Gebrüder Trox GmbH (12/2001) · Leaflet No. E016NA2
- Page 1 and 2: VARYCONTROL Reference List Design a
- Page 3 and 4: Reference list VARYCONTROL KADEWE-B
- Page 5 and 6: TVZ · TVA TVM TVR TVRK TVJ/TVT Des
- Page 7 and 8: Room Temperature Control Circuit Se
- Page 9 and 10: Single Duct System with Reheat Coil
- Page 11: Explanation of Order Codes The cont
- Page 15 and 16: Installation TVZ . TVA Delivery and
- Page 17 and 18: Installation TVJ with TX TVJ/TVT wi
- Page 19 and 20: Disengaging the Drive Function Test
- Page 21 and 22: TVRK Volume Flow Controller and Tra
- Page 23 and 24: Removing tubes Maintenance 1 Specia
- Page 25 and 26: VRD2 VRD2 Tube connection for trans
- Page 27 and 28: Pressure Independent Control Charac
- Page 29 and 30: Volume Flow Ranges TVZ, TVA, TVR, T
- Page 31 and 32: Volume Flow Ranges TVM Size V · mi
- Page 33 and 34: Override Controls RT Controller Ope
- Page 35 and 36: Function Test Fault Finding Check C
- Page 37 and 38: VRP � � � � Characteristic
- Page 39 and 40: VRP Adjustment Knobs � � �
- Page 41 and 42: Volume Flow Control Tolerances 1) V
- Page 43 and 44: Terminal Connections Plug connectio
- Page 45 and 46: Function Test Fault Finding Check C
- Page 47 and 48: VRP-STP Area of Application ��
- Page 49 and 50: Room Pressure Ranges Differential p
- Page 51 and 52: Parallel Differential Pressure Cont
- Page 53 and 54: Belimo VFP 1 Contents Subject Page
- Page 55 and 56: Belimo VFP Zero Point Adjustment
- Page 57 and 58: NM 24-V � Shaft clamp � Directi
- Page 59 and 60: Belimo VAV-Compact NMV-D2 1 Content
- Page 61 and 62: Belimo VAV-Compact NMV-D2 Character
Design and Areas of Application<br />
Nomenclature<br />
TVZ VAV terminal box with integrated silencer,<br />
for supply air<br />
TVA VAV terminal box with integrated silencer,<br />
for extract air<br />
TVR VAV terminal box with integrated silencer,<br />
for supply and extract air<br />
9<br />
TVJ VAV terminal box, casing rectangular<br />
TVT VAV controller, casing rectangular, control<br />
damper leakage complies with DIN 1946, part 4<br />
TVM VAV dual duct etrminal box<br />
...-D Additional acoustic cladding