Celerity Fibre Channel Host Adapters Selection Guide - Storesys
Celerity Fibre Channel Host Adapters Selection Guide - Storesys
Celerity Fibre Channel Host Adapters Selection Guide - Storesys
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
<strong>Celerity</strong> <strong>Fibre</strong> <strong>Channel</strong> <strong>Host</strong> <strong>Adapters</strong><br />
<strong>Selection</strong> <strong>Guide</strong><br />
Product<br />
Features<br />
<strong>Celerity</strong> <strong>Host</strong> <strong>Adapters</strong><br />
FC-84EN FC-82EN FC-81EN FC-44ES FC-42ES FC-41ES FC-42XS FC-41XS<br />
<strong>Fibre</strong> <strong>Channel</strong> Ports 4 2 1 4 2 1 2 1<br />
Maximum Data Rate 8Gb 8Gb 8Gb 4Gb 4Gb 4Gb 4Gb 4Gb<br />
Maximum Transfer Rate<br />
(full duplex)<br />
Maximum Transfer Rate<br />
(half duplex)<br />
6.4 GB/s 3.2 GB/s 1.6 GB/s 3.2 GB/s 1.6 GB/s 800 MB/s 1.6 GB/s 800 MB/s<br />
3.2 GB/s 1.6 GB/s 800 MB/s 1.6 GB/s 800 MB/s 400 MB/s 800 MB/s 400 MB/s<br />
Bus Type PCIe 2.0 PCIe 2.0 PCIe 2.0 PCIe PCIe PCIe PCI-X PCI-X<br />
Bus Characteristics x8 x8 x8 x8 x4 x4<br />
64-bit, 133<br />
MHz<br />
64-bit, 133<br />
MHz<br />
Optical Interface SFP+LC SFP+LC SFP+LC SFP LC SFP LC SFP LC SFP LC SFP LC<br />
Maximum Cable Length<br />
Low-Profile Form<br />
Factor<br />
300m - 2Gb<br />
150m - 4Gb<br />
50m - 8Gb<br />
300m - 2Gb<br />
150m - 4Gb<br />
50m - 8Gb<br />
300m - 2Gb<br />
150m - 4Gb<br />
50m - 8Gb<br />
300m - 2Gb<br />
150m - 4Gb<br />
300m - 2Gb<br />
150m - 4Gb<br />
300m - 2Gb<br />
150m - 4Gb<br />
300m - 2Gb<br />
150m - 4Gb<br />
300m - 2Gb<br />
150m - 4Gb<br />
Advanced Data<br />
Streaming (ADS)<br />
Software RAID Support<br />
Developer's Kit (Target<br />
Mode & API)<br />
Windows®<br />
Linux® (Red Hat, SUSE)<br />
Mac® OS X<br />
VMware® ESX Server<br />
Novell® Netware<br />
Solaris®<br />
FreeBSD®<br />
RoHS Compliant<br />
9/09
Tech Sheet<br />
8Gb/s <strong>Fibre</strong> <strong>Channel</strong> <strong>Host</strong> Bus <strong>Adapters</strong><br />
<strong>Celerity</strong> FC-84EN<br />
<strong>Celerity</strong> FC-82EN<br />
<strong>Celerity</strong> FC-81EN<br />
ATTO’s <strong>Celerity</strong> 8Gb/s <strong>Fibre</strong> <strong>Channel</strong> <strong>Host</strong> Bus <strong>Adapters</strong><br />
provide the highest performing SAN storage connectivity for<br />
media and entertainment and general IT workflows.<br />
Industry Proven Technology<br />
ATTO has over 15 years of experience developing high performance and reliable <strong>Fibre</strong><br />
<strong>Channel</strong> storage connectivity to deliver first-to-market solutions to customers. <strong>Celerity</strong> host<br />
bus adapters are consistently the highest performing HBAs for video editing, digital audio,<br />
video on demand, or database applications. The integrated family of <strong>Celerity</strong> 8Gb/s <strong>Fibre</strong><br />
<strong>Channel</strong> host bus adapters boast an extensive list of customer design wins and<br />
certifications with respected industry partners.<br />
Flexible Connectivity Solutions<br />
With single-, dual- and quad-channel configurations, <strong>Celerity</strong> 8Gb/s <strong>Fibre</strong> <strong>Channel</strong> HBAs are<br />
an ideal solution for users looking to achieve the highest I/O and data throughput for<br />
advanced video and enterprise-class IT applications. <strong>Celerity</strong> 8Gb/s host bus adapters offer<br />
driver support for Windows®, Linux, Mac® OS X and VMware®, providing a single<br />
connectivity solution for customers with heterogeneous operating system environments.<br />
Performance Engineered<br />
<strong>Celerity</strong> HBAs are designed to provide fast, redundant and highly available connectivity to<br />
<strong>Fibre</strong> <strong>Channel</strong> storage, and are engineered to manage latency for real-time applications.<br />
ATTO’s exclusive Advanced Data Streaming (ADS) technology provides controlled<br />
acceleration of data to deliver the highest consistent performance and reliable data<br />
transfers. ATTO pays close attention to detail in board design and signal integrity to<br />
minimize transmission errors and data corruption. Specialized <strong>Fibre</strong> <strong>Channel</strong> drivers with<br />
support for multiple OS platforms and OEM-specific solutions such as target mode and<br />
multipathing, make ATTO the premier choice for high-performance <strong>Fibre</strong> <strong>Channel</strong> SAN<br />
connectivity.<br />
Advanced Management Tools<br />
ATTO’s easy-to-use Configuration Tool features an intuitive GUI that simplifies the<br />
installation, management and monitoring of the host bus adapter. With advanced<br />
troubleshooting and performance tuning capabilities, <strong>Celerity</strong> HBAs provide users with<br />
sophisticated diagnostics and the flexibility to control settings for specific applications.<br />
Technical Features<br />
• Single-, Dual- and Quad-<strong>Channel</strong><br />
configurations<br />
• 1600 MB/s per channel throughput in full<br />
-duplex mode<br />
• Driver support for Windows®, Linux, Mac®<br />
OS X, VMware® and more<br />
• Exclusive Advanced Data Streaming<br />
(ADS) Technology<br />
• ATTO Configuration Tool for customized<br />
performance settings<br />
• Proven interoperable with leading<br />
storage hardware and software vendors<br />
• Complete SAN connectivity when<br />
combined with ATTO <strong>Fibre</strong>Connect<br />
8Gb/s <strong>Fibre</strong> <strong>Channel</strong> switches<br />
• Support for N_Port ID Virtualization and<br />
Virtual Fabric<br />
• Target mode support<br />
• Low power consumption<br />
• 3-year standard product warranty<br />
MultiPath Director<br />
High-availability storage connectivity<br />
solution for Media and Entertainment<br />
• Multiple paths to storage for improved<br />
data integrity and reliability<br />
• High-performance shared storage for<br />
workgroups<br />
• Load-balancing and failover in<br />
heterogeneous OS environments<br />
attotech.com 716.691.1999
8Gb/s <strong>Fibre</strong> <strong>Channel</strong> <strong>Host</strong> Bus <strong>Adapters</strong><br />
<strong>Celerity</strong> FC-84EN, FC-82EN, FC-81EN<br />
Tech Sheet<br />
Technical Specifications<br />
Applications<br />
<strong>Celerity</strong> <strong>Fibre</strong> <strong>Channel</strong> host bus adapters deliver high-performance and reliable connectivity solutions for the most demanding storage environments, including digital content<br />
creation, tape streaming and backup, rich content delivery, server clustering, and complex databases. <strong>Celerity</strong> HBAs enable users to achieve the ultimate in I/O performance for<br />
real-time and transactional applications.<br />
Advanced Data Streaming (ADS)<br />
Latency-management technology that controls the<br />
acceleration of data transfers to move large<br />
amounts of data faster and more efficiently.<br />
Key Features<br />
▪ Auto Negotiation to 8Gb, 4Gb and 2Gb devices<br />
▪ Supports arbitrated loop, point-to-point and<br />
direct fabric/switch attach<br />
▪ ANSI <strong>Fibre</strong> <strong>Channel</strong>: FC-FS, FCP, FC-AL, FC-AL2,<br />
FC-PLDA, FC-FLA<br />
▪ Flash ROM for easy field upgrades<br />
▪ FC Class 3 Support<br />
▪ Buffer Credits: 41<br />
▪ Software RAID support with ATTO’s Power<br />
Center software<br />
▪ Pluggable optical LC SFP+<br />
▪ Initiator and target mode (OEM) support<br />
▪ Supports Windows FDMI and WMI<br />
▪ Supports NPIV and Virtual Fabric<br />
User Benefits<br />
▪ Superior performance for enterprise<br />
applications<br />
▪ Low power consumption<br />
▪ Quad port card maximizes usage of server slots<br />
▪ Increased switch port availability<br />
▪ Reduced cost per MB of data transferred<br />
▪ Seamless integration into existing FC SANs<br />
▪ Support for virtualized server environments<br />
▪ Extensive certification with SAN infrastructure<br />
components<br />
Management Tools<br />
▪ ATTO Config Tool (w/GUI) BIOS-based<br />
management and configuration utility<br />
Bus Specifications<br />
▪ x8 PCI Express 2.0 host interface<br />
▪ Supports PCI Express Base Spec 2.0<br />
▪ Supports PCI Express CEM Spec 2.0<br />
▪ PCI Hot Plug spec 1.0<br />
External Connectivity<br />
▪ Standard size brackets installed with spare low<br />
profile brackets for FC-82EN, FC-81EN<br />
▪ Single (1), Dual (2) or Quad (4) pluggable 8Gb<br />
optical LC SFP+ modules included<br />
▪ External LEDs for on-line and speed status for<br />
each port<br />
Operating System Support<br />
▪ Windows® Server 2003, 2008<br />
▪ Windows XP, Vista, 7<br />
▪ SUSE Linux<br />
▪ Red Hat Linux<br />
▪ Mac OS® X 10.4.x & later<br />
▪ VMware ESX Server® 3.5 - 4.x<br />
▪ VMware ESXi Server® 4.x - 5.x<br />
Agency Approvals<br />
▪ FCC Part 15, Subpart B, Class A (FC-84EN),<br />
Class B (FC-82EN & FC-81EN )<br />
▪ EN55024: 1998A + A1: 2001 & A2: 2003<br />
▪ EN60825-1: 1994-2: 2004<br />
▪ EN55022: 2006, Class A FC-84EN),<br />
Class B (FC-82EN & FC-81EN )<br />
Compliance<br />
▪ EN60950-1: 2001<br />
▪ RoHS<br />
Dimensions<br />
FC-84EN<br />
▪ Length 6.525”, Height 3.987”<br />
FC-82EN, FC-81EN<br />
▪ Length 6.600”, Height 2.731”<br />
Operating Temperature<br />
Hardware Environment<br />
▪ Temperature: 0-40° C<br />
▪ Humidity: 10 - 90% non-condensing<br />
Storage Environment<br />
▪ Temperature: -40°-70°C (-40°-157°F)<br />
▪ Humidity: 5 - 95% non-condensing<br />
Operating Voltage<br />
FC-84EN<br />
▪ 7.8W (typical)<br />
FC-82EN<br />
▪ 5.9W (typical)<br />
FC-81EN<br />
▪ 5.3W (typical)<br />
Airflow<br />
▪ 100 lf/m (min) recommended<br />
Warranty<br />
▪ 3 Year<br />
ATTO <strong>Celerity</strong> FC-84EN<br />
Ports 4<br />
Bus Characteristics x8 PCIe 2.0<br />
Form Factor<br />
Max. Transfer Rate<br />
(Full duplex)<br />
(Half duplex)<br />
Full Height<br />
6.4GB/s<br />
3.2GB/s<br />
ATTO <strong>Celerity</strong> FC-82EN<br />
Ports 2<br />
Bus Characteristics x8 PCIe 2.0<br />
Form Factor<br />
Max. Transfer Rate<br />
(Full duplex)<br />
(Half duplex)<br />
Low Profile<br />
3.2GB/s<br />
1.6GB/s<br />
ATTO <strong>Celerity</strong> FC-81EN<br />
Ports 1<br />
Bus Characteristics x8 PCIe 2.0<br />
Form Factor<br />
Max. Transfer Rate<br />
(Full duplex)<br />
(Half duplex)<br />
Low Profile<br />
1.6GB/s<br />
800MB/s<br />
Part Number<br />
CTFC-84EN-000<br />
Part Number<br />
CTFC-82EN-000<br />
Part Number<br />
CTFC-81EN-000<br />
attotech.com 716.691.1999<br />
9/11 Product features and specifications are subject to change without notice.
Tech Sheet<br />
4Gb/s PCIe <strong>Fibre</strong> <strong>Channel</strong> <strong>Host</strong> Bus <strong>Adapters</strong><br />
<strong>Celerity</strong> FC-44ES<br />
<strong>Celerity</strong> FC-42ES<br />
<strong>Celerity</strong> FC-41ES<br />
ATTO’s <strong>Celerity</strong> 4Gb/s <strong>Fibre</strong> <strong>Channel</strong> <strong>Host</strong> Bus <strong>Adapters</strong><br />
provide efficient data transfers for editing and producing<br />
content in media and entertainment and general IT workflows.<br />
Industry Proven Technology<br />
ATTO has over 15 years of experience developing high performance and reliable <strong>Fibre</strong><br />
<strong>Channel</strong> storage connectivity to deliver first-to-market solutions to customers. <strong>Celerity</strong> host<br />
bus adapters are consistently the highest performing HBAs for video editing, digital audio,<br />
video on demand, or database applications. The integrated family of <strong>Celerity</strong> 4Gb/s PCIe<br />
<strong>Fibre</strong> <strong>Channel</strong> host bus adapters boast an extensive list of design wins and certifications<br />
with respected industry partners.<br />
Flexible Connectivity Solutions<br />
With single-, dual- and quad-channel configurations, <strong>Celerity</strong> 4Gb/s PCIe <strong>Fibre</strong> <strong>Channel</strong><br />
HBAs are an ideal solution for users looking to achieve the highest I/O and data throughput<br />
for high-bandwidth workflows. <strong>Celerity</strong> 4Gb/s PCIe host bus adapters offer driver support<br />
for Windows®, Linux, Mac® OS X and VMware®, providing a single connectivity solution for<br />
customers with heterogeneous operating system environments.<br />
Performance Engineered<br />
<strong>Celerity</strong> HBAs are designed to provide fast, redundant and highly available connectivity to<br />
storage, and are engineered to manage latency for real-time applications. ATTO’s exclusive<br />
Advanced Data Streaming (ADS) technology provides controlled acceleration of data to<br />
deliver the highest consistent performance and reliable data transfers. ATTO pays close<br />
attention to detail in board design and signal integrity to minimize transmission errors and<br />
data corruption. Specialized <strong>Fibre</strong> <strong>Channel</strong> drivers with support for multiple OS platforms<br />
and OEM-specific solutions such as target mode and multipathing, make ATTO the premier<br />
choice for high-performance <strong>Fibre</strong> <strong>Channel</strong> SAN connectivity.<br />
Technical Features<br />
• Single-, Dual- and Quad-<strong>Channel</strong><br />
configurations<br />
• 800 MB/s per channel throughput in fullduplex<br />
mode<br />
• Available in a low-profile form factor<br />
• Driver support for Windows®, Linux, Mac®<br />
OS X, VMware® and more<br />
• Exclusive Advanced Data Streaming<br />
(ADS) Technology<br />
• ATTO Configuration Tool for customized<br />
performance settings<br />
• Proven interoperable with leading<br />
storage hardware and software vendors<br />
• Complete SAN connectivity when<br />
combined with ATTO <strong>Fibre</strong>Connect<br />
8Gb/s <strong>Fibre</strong> <strong>Channel</strong> switches<br />
• Target mode support<br />
• Low power consumption<br />
• 3-year standard product warranty<br />
Advanced Management Tools<br />
ATTO’s easy-to-use Configuration Tool features an intuitive GUI that simplifies the<br />
installation, management and monitoring of the host bus adapter. With advanced<br />
troubleshooting and performance tuning capabilities, <strong>Celerity</strong> HBAs provide users with<br />
sophisticated diagnostics and the flexibility to control settings for specific applications.<br />
attotech.com 1.716.691.1999
4Gb/s PCIe <strong>Fibre</strong> <strong>Channel</strong> <strong>Host</strong> Bus <strong>Adapters</strong><br />
<strong>Celerity</strong> FC-44ES, FC-42ES, FC-41ES<br />
Tech Sheet<br />
Technical Specifications<br />
Applications<br />
<strong>Celerity</strong> <strong>Fibre</strong> <strong>Channel</strong> host bus adapters deliver high-performance and reliable connectivity solutions for the most demanding storage environments, including digital content<br />
creation, tape streaming and backup, rich content delivery, server clustering, and complex databases. <strong>Celerity</strong> HBAs enable users to achieve the ultimate in I/O performance for<br />
real-time and transactional applications.<br />
Advanced Data Streaming (ADS)<br />
Latency-management technology that controls the<br />
acceleration of data transfers to move large<br />
amounts of data faster and more efficiently.<br />
Key Features<br />
▪ Auto Negotiation to 4Gb, 2Gb and 1Gb devices<br />
▪ Supports arbitrated loop, point-to-point and<br />
direct fabric/switch attach<br />
▪ ANSI <strong>Fibre</strong> <strong>Channel</strong>: FC-PH, FC-FCP, FC-AL, FC-<br />
AL2, FC-PLDA, FC-FLA<br />
▪ Flash ROM for easy field upgrades<br />
▪ FC Class 3 Support<br />
▪ Buffer Credits: 8 @ 512 Bytes; 8 @ 2KB<br />
▪ Software RAID support with ATTO’s Power<br />
Center software<br />
▪ Initiator and target mode (OEM) support<br />
▪ Supports Windows FDMI and WMI<br />
▪ Local management and diagnostics<br />
User Benefits<br />
▪ High performance and scalable connectivity<br />
▪ Optimized for video applications<br />
▪ Low power consumption<br />
▪ Seamless integration into existing FC SANs<br />
▪ Support for virtualized server environments<br />
▪ Ease of use and sophisticated management<br />
capabilities<br />
▪ Extensive certifications with SAN infrastructure<br />
components<br />
Management Tools<br />
▪ ATTO Config Tool (w/GUI) BIOS-based<br />
management and configuration utility<br />
Bus Specifications<br />
▪ x8 (FC-44ES) and x4 (FC-42ES, FC-41ES) PCI<br />
Express host interface<br />
▪ Supports PCI Express Base Spec 1.0a<br />
▪ Supports PCI Express CEM Spec 1.0a<br />
▪ PCI Express to PCI/PCI-X bridge Spec 1.0<br />
External Connectivity<br />
▪ Standard size brackets installed with spare low<br />
profile brackets for FC-42ES, FC-41ES<br />
▪ Single (1), Dual (2) or Quad (4) pluggable 4Gb<br />
optical LC SFP modules included<br />
▪ External LEDs for on-line and speed status for<br />
each port<br />
Operating System Support<br />
▪ Windows® Server 2003, 2008,<br />
▪ Windows XP, Vista, 7<br />
▪ SUSE Linux<br />
▪ Red Hat Linux<br />
▪ Mac ®OS X (10.4.x - 10.6.x)<br />
▪ VMware® ESX Server 3.5<br />
▪ Novell Netware<br />
▪ Solaris 9 & 10<br />
Agency Approvals<br />
▪ FCC Part 15, Class B<br />
▪ CISPR 22:2002<br />
▪ EN55022: 2002, Class B<br />
Compliance<br />
▪ RoHS<br />
Dimensions<br />
FC-44ES<br />
▪ Length 6.600”, Height 3.987”<br />
FC-42ES, FC-41ES<br />
▪ Length 5.600”, Height 2.712”<br />
Operating Temperature<br />
Hardware Environment<br />
▪ Temperature: 0-45°C (32°-113°F)<br />
▪ Humidity: 5 - 95% non-condensing<br />
Storage Environment<br />
▪ Temperature: -40°-70°C (-40°-157°F)<br />
▪ Humidity: 5 - 95% non-condensing<br />
Operating Voltage<br />
FC-44ES<br />
▪ 12V@2.1A max, 3.3V@3.0A max<br />
FC-42ES<br />
▪ 12V@0.4A max, 3.3V@1.5A max<br />
FC-41ES<br />
▪ 12V@0.4A max, 3.3V@1.0A max<br />
Airflow<br />
▪ 100 lf/m (min) recommended<br />
Warranty<br />
▪ 3 Year<br />
ATTO <strong>Celerity</strong> FC-44ES<br />
Ports 4<br />
ATTO <strong>Celerity</strong> FC-42ES<br />
Ports 2<br />
ATTO <strong>Celerity</strong> FC-41ES<br />
Ports 1<br />
Bus Characteristics<br />
x8 PCIe<br />
Bus Characteristics<br />
x4 PCIe<br />
Bus Characteristics<br />
x4 PCIe<br />
Form Factor<br />
Full Height<br />
Form Factor<br />
Low Profile<br />
Form Factor<br />
Low Profile<br />
Max. Transfer Rate<br />
(Full duplex)<br />
(Half duplex)<br />
3.2GB/s<br />
1.6GB/s<br />
Max. Transfer Rate<br />
(Full duplex)<br />
(Half duplex)<br />
1.6GB/s<br />
800MB/s<br />
Max. Transfer Rate<br />
(Full duplex)<br />
(Half duplex)<br />
800MB/s<br />
400MB/s<br />
Part Number<br />
CTFC-44ES-000<br />
Part Number<br />
CTFC-42ES-000<br />
Part Number<br />
CTFC-41ES-000<br />
attotech.com 1.716.691.1999<br />
2/11 Product features and specifications are subject to change without notice.
Tech Sheet<br />
6Gb/s SAS/SATA <strong>Host</strong> Bus <strong>Adapters</strong><br />
ExpressSAS H6F0<br />
ExpressSAS H60F<br />
ExpressSAS H680<br />
ExpressSAS H608<br />
ExpressSAS H644<br />
ATTO’s first-to-market ExpressSAS 6Gb/s SAS/SATA <strong>Host</strong><br />
Bus <strong>Adapters</strong> boast the highest available SAS and SATA<br />
performance for Direct Attached Storage infrastructures.<br />
Industry Proven Technology<br />
The ExpressSAS 6Gb/s host bus adapter product line was the first 6Gb/s-based family of<br />
HBAs available in the market. ExpressSAS 6Gb/s host bus adapters double the performance<br />
of 3Gb/s SAS/SATA host bus adapters and work seamlessly with a wide array of 3rd party<br />
products, including HDDs and SSDs, tape drives and many other SAS and SATA<br />
infrastructure products.<br />
Flexible Connectivity Solutions<br />
ExpressSAS 6Gb/s SAS/SATA HBAs are available in the widest selection of port<br />
configurations, providing the most flexible connectivity to SAS/SATA storage. With 8<br />
external, 8 internal, 4 external/4 internal, or a two-host-adapters-in-one configuration with<br />
16 external or 16 internal ports, users benefit from efficient scalability and more options<br />
from which to choose the best SAS/SATA HBA for their application.<br />
Performance Engineered<br />
ExpressSAS 6Gb/s host bus adapters combine 6Gb/s SAS speeds and x8 PCI Express 2.0<br />
with powerful hardware and software elements to manage latency in real-time<br />
environments. Exclusive Advanced Data Streaming (ADS) Technology maximizes CPU<br />
processes to deliver smooth and reliable data transfers and the highest consistent<br />
performance. ATTO pays close attention to detail in board design and signal integrity to<br />
minimize transmission errors and data corruption. These differentiating capabilities make<br />
ATTO the premier choice for high-performance direct-attached SAS/SATA storage<br />
connectivity.<br />
Advanced Management Tools<br />
ATTO’s easy-to-use Configuration Tool features an intuitive GUI that simplifies the<br />
installation, management and monitoring of the host bus adapter. With advanced<br />
troubleshooting and performance tuning capabilities, ExpressSAS HBAs provide users with<br />
sophisticated diagnostics and the flexibility to control settings for specific applications.<br />
Technical Features<br />
• Port configurations include 16 external,<br />
16 internal, 8 external, 8 internal, and<br />
4 external/4 internal<br />
• 1200 MB/s per port/phy throughput in<br />
full-duplex mode<br />
• Features a high-performance x8 PCIe<br />
2.0 host interface<br />
• SAS 2.0, SAS, SATA and SATA II support<br />
• Supports up to 512 SAS/SATA devices<br />
• Driver support for Windows®, Linux,<br />
Mac® OS X, VMware® and more<br />
• Exclusive Advanced Data Streaming<br />
(ADS) Technology<br />
• Proven interoperability with support for<br />
SNIA HBA API<br />
• ATTO Configuration Tool for<br />
customized performance settings<br />
• Low power consumption<br />
• Target mode support<br />
• 3-year standard product warranty<br />
attotech.com 716.691.1999
6Gb/s SAS/SATA <strong>Host</strong> Bus <strong>Adapters</strong><br />
ExpressSAS H6F0, H60F, H680, H608, H644<br />
Tech Sheet<br />
Technical Specifications<br />
Applications<br />
ExpressSAS 6Gb/s SAS/SATA host bus adapters offer the fastest available connection to direct-attached SAS or SATA storage. The impressive speed of the ExpressSAS family of<br />
next-generation 6Gb/s HBAs delivers a future-proof solution for data-intensive IT and digital media applications such as tape backup, data warehousing, high-definition video,<br />
post-production, and digital film production.<br />
Dimensions<br />
Advanced Data Streaming (ADS)<br />
Latency-management technology that controls the<br />
acceleration of data transfers to move large<br />
amounts of data faster and more efficiently.<br />
Key Features<br />
▪ SAS 2.0, SAS, SATA and SATA II support<br />
▪<br />
▪<br />
▪<br />
▪<br />
▪<br />
▪<br />
▪<br />
▪<br />
▪<br />
Auto Negotiation between 6Gb/s, 3Gb/s and<br />
1.5Gbs devices<br />
Supports SSP, SMP, STP protocols<br />
SGPIO support<br />
PC BIOS bootability<br />
Global and dedicated hot spares<br />
SES, SNMP and S.M.A.R.T. support<br />
Initiator and target mode (OEM) support<br />
Flash ROM for easy field updates<br />
Wide-port end device support<br />
User Benefits<br />
▪ Highest available MB/s and IOPS performance<br />
▪<br />
▪<br />
▪<br />
Superior system performance with latest SAS/<br />
SATA technology<br />
Low power consumption<br />
Support for virtualized server environments<br />
Management Tools<br />
▪ Command Line Interface for advanced<br />
functionality<br />
▪ ATTO Config Tool (w/GUI) BIOS-based<br />
management and configuration utility<br />
Bus Specifications<br />
▪ x8 PCI Express 2.0 host interface<br />
▪ Supports PCI Express Base Spec 2.0<br />
▪ Supports PCI Express CEM Spec 2.0<br />
External Connectivity<br />
▪ Low profile (H60F, H680, H608, H644) and full<br />
height (H6F0) bracket<br />
▪ x4 MiniSAS Connectors<br />
▪ External LEDs for on-line and speed status for<br />
each port<br />
Operating System Support<br />
▪ Windows® Server 2003, 2008,<br />
▪ Windows XP, Vista, 7<br />
▪ Red Hat & SUSE Linux<br />
▪ Mac ®OS X (10.4.x - 10.6.x)<br />
▪ VMware® ESX Server 3.5<br />
▪ VMware® ESX Server vSphere 4.1<br />
Agency Approvals<br />
▪ FCC Part 15, Subpart B, Class A<br />
▪ EN55024: 1998A + A1: 2001 & A2: 2003<br />
▪ EN60825-1: 1994-2: 2004<br />
▪ EN55022: 2006, Class B<br />
Compliance<br />
▪ EN60950-1: 2001<br />
▪ RoHS Compliant<br />
H6F0<br />
▪ Length 6.600”, Height 4.376”<br />
H60F<br />
▪ Length 8.638”, Height 2.846”<br />
H680<br />
▪ Length 6.600”, Height 2.731”<br />
H608, H644<br />
▪ Length 5.600”, Height 2.731”<br />
Operating Temperature<br />
Hardware Environment<br />
▪ Temperature: 0-40°C (34°-104°F)<br />
▪ Humidity: 10 - 90% non-condensing<br />
Storage Environment<br />
▪ Temperature: -40°-70°C (-40°-157°F)<br />
▪ Humidity: 5 - 95% non-condensing<br />
Operating Voltage<br />
H6F0, H60F<br />
▪ 22W (typical)<br />
H680<br />
▪ 7.8W (typical)<br />
H608, H644<br />
▪ 8.3W (typical)<br />
Airflow<br />
▪ 100 lf/m (min) recommended<br />
Warranty<br />
▪ 3 Year<br />
TTO<br />
ATTO ExpressSAS<br />
H6F0<br />
ATTO ExpressSAS<br />
H60F<br />
ATTO ExpressSAS<br />
H680<br />
ATTO ExpressSAS<br />
H608<br />
ATTO ExpressSAS<br />
H644<br />
Ports 16 External 16 Internal 8 External 8 Internal 4 External/4 Internal<br />
Bus Characteristics x8 PCIe 2.0 x8 PCIe 2.0 x8 PCIe 2.0 x8 PCIe 2.0 x8 PCIe 2.0<br />
Form Factor Full Height Low Profile Low Profile Low Profile Low Profile<br />
Connectors<br />
4 Mini SAS (x4)<br />
SFF 8088 External<br />
4 Mini SAS (x4)<br />
SFF 8087 Internal<br />
2 Mini SAS (x4)<br />
SFF 8088 External<br />
2 Mini SAS (x4)<br />
SFF 8087 Internal<br />
1 Mini SAS (x4)<br />
SFF 8088 External<br />
1 Mini SAS (x4)<br />
SFF 8087 Internal<br />
Device Support 512 512 256 256 256<br />
Part Number ESAS-H6F0-000 ESAS-H60F-000 ESAS-H680-000 ESAS-H608-000 ESAS-H644-000<br />
attotech.com 716.691.1999<br />
2/11 Product features and specifications are subject to change without notice.
Tech Sheet<br />
3Gb/s SAS/SATA <strong>Host</strong> Bus <strong>Adapters</strong><br />
ExpressSAS H30F<br />
ExpressSAS H380<br />
ExpressSAS H308<br />
ATTO’s ExpressSAS 3Gb/s SAS/SATA <strong>Host</strong> Bus <strong>Adapters</strong><br />
provide high-performance connectivity for a wide range<br />
of Direct Attached Storage infrastructures.<br />
Industry Proven Technology<br />
ExpressSAS 3Gb/s host bus adapters leverage the performance and reliability<br />
enhancements of Serial Attached SCSI (SAS) technology to deliver high performance<br />
connectivity to SAS/SATA storage. ExpressSAS HBAs are engineered for the most stringent<br />
digital media workgroup and IT server environments, and are compatible with a wide array<br />
of 3rd party products, such as HDDs and SSDs, storage arrays and many other SAS and<br />
SATA infrastructure products.<br />
Flexible Connectivity Solutions<br />
ExpressSAS 3Gb/s SAS/SATA HBA’s provide flexible connectivity to SAS/SATA storage. With<br />
16 internal, 8 external or 8 internal port configurations, users benefit from cost-effective<br />
and efficient scalability. With support for SAS, SATA and SATA II connectivity, ExpressSAS<br />
3Gb/s host bus adapters are ideal for a variety of storage environments.<br />
Performance Engineered<br />
ExpressSAS 3Gb/s host bus adapters combine 3Gb/s SAS speeds and x8 PCI Express with<br />
powerful hardware and software elements to manage latency in real-time environments.<br />
Exclusive Advanced Data Streaming (ADS) Technology maximizes CPU processes to<br />
deliver smooth and reliable data transfers and the highest consistent performance. ATTO<br />
pays close attention to detail in board design and signal integrity to minimize transmission<br />
errors and data corruption. These differentiating capabilities make ATTO the premier<br />
choice for high-performance direct-attached SAS/SATA storage connectivity.<br />
Technical Features<br />
• Port configurations include 16 internal,<br />
8 external and 8 internal<br />
• 600 MB/s per port/phy throughput in<br />
full-duplex mode<br />
• Features a high-performance x8 PCIe<br />
host interface<br />
• Low-profile form factor<br />
• SAS, SATA and SATA II connectivity<br />
• Supports up to 256 SAS/SATA devices<br />
• Driver support for Windows®, Linux,<br />
Mac® OS X, VMware® and more<br />
• Exclusive Advanced Data Streaming<br />
(ADS) Technology<br />
• Proven interoperability with support for<br />
SNIA HBA API<br />
• ATTO Configuration Tool for<br />
customized performance settings<br />
• Low power consumption<br />
• 3-year standard product warranty<br />
Advanced Management Tools<br />
ATTO’s easy-to-use Configuration Tool features an intuitive GUI that simplifies the<br />
installation, management and monitoring of the host bus adapter. With advanced<br />
troubleshooting and performance tuning capabilities, ExpressSAS HBAs provide users with<br />
sophisticated diagnostics and the flexibility to control settings for specific applications.<br />
attotech.com 716.691.1999
3Gb/s SAS/SATA <strong>Host</strong> Bus <strong>Adapters</strong><br />
ExpressSAS H30F, H380, H308<br />
Tech Sheet<br />
Technical Specifications<br />
Applications<br />
ExpressSAS 3Gb/s SAS/SATA host adapters deliver high performance connectivity to direct attached SAS or SATA storage. The impressive performance of the ExpressSAS family<br />
of 3Gb/s HBAs is perfect for a wide array of data-intensive IT and digital media applications such as tape backup, data warehousing, high-definition video, post-production, and<br />
digital film production.<br />
Advanced Data Streaming (ADS)<br />
Latency-management technology that controls the<br />
acceleration of data transfers to move large<br />
amounts of data faster and more efficiently.<br />
Key Features<br />
▪ SAS, SATA and SATA II support<br />
▪<br />
▪<br />
▪<br />
▪<br />
▪<br />
▪<br />
▪<br />
Auto Negotiation between 3Gb/s and 1.5Gb/s<br />
devices<br />
Supports SSP, SMP, STP protocols<br />
PC BIOS bootability<br />
SGPIO support<br />
SES, SNMP and S.M.A.R.T. support<br />
Flash ROM for easy field updates<br />
Advanced management functions<br />
User Benefits<br />
▪ High performance (MB/s and IOPS)<br />
▪<br />
▪<br />
▪<br />
Superior system performance with SAS/SATA<br />
technology<br />
Low power consumption<br />
Support for virtualized server environments<br />
Management Tools<br />
▪ Command Line Interface for advanced<br />
functionality<br />
▪ ATTO Config Tool (w/GUI) BIOS-based<br />
management and configuration utility<br />
Bus Specifications<br />
▪ x8 PCI Express host interface<br />
▪ Supports PCI Express Base Spec 1.0a<br />
External Connectivity<br />
▪ Low profile bracket<br />
▪ x4 MiniSAS Connectors<br />
▪<br />
External LEDs for on-line and speed status for<br />
each port<br />
Operating System Support<br />
▪ Windows Server 2003, 2008, XP, Vista, 7<br />
▪ Red Hat & SUSE Linux<br />
▪ Mac OS X (10.4.x - 10.6.x)<br />
▪ VMware® ESX Server 3.5<br />
Agency Approvals<br />
▪ FCC Part 15, Class B<br />
▪ CISPR 22:2002<br />
▪ EN55022: 2002, Class B<br />
Compliance<br />
▪ RoHS<br />
Dimensions<br />
H30F<br />
▪ Length 6.600”, Height 2.900”<br />
H380, H308<br />
▪ Length 5.600”, Height 2.731”<br />
Operating Temperature<br />
Hardware Environment<br />
▪ Temperature: 0-60°C (32°-140°F) at 300 lf/m<br />
airflow<br />
▪ Temperature: 0-40°C (32°-104°F) at 150 lf/m<br />
airflow<br />
▪ Humidity: 5 - 95% non-condensing<br />
Storage Environment<br />
▪ Temperature: -40°-70°C (-40°-157°F)<br />
▪ Humidity: 5 - 95% non-condensing<br />
Operating Voltage<br />
H30F<br />
▪ 12V @ 1.45A max.<br />
▪ 3.3V @ .50A max<br />
▪ 19W (typical)<br />
H380<br />
▪ 12V @ .59A max.<br />
▪ 3.3V @ .87A max.<br />
▪ 10W (typical)<br />
H308<br />
▪ 12V @ 1.05A max.<br />
▪ 3.3V @ .45A max<br />
▪ 10W (typical)<br />
Airflow<br />
▪ 150 lf/m (min) recommended<br />
Warranty<br />
▪ 3 Year<br />
ATTO ExpressSAS H30F<br />
ATTO ExpressSAS H380<br />
ATTO ExpressSAS H308<br />
Ports<br />
16 Internal<br />
Ports<br />
8 External<br />
Ports<br />
8 Internal<br />
Bus Characteristics<br />
x8 PCIe<br />
Bus Characteristics<br />
x8 PCIe<br />
Bus Characteristics<br />
x8 PCIe<br />
Form Factor<br />
Low Profile<br />
Form Factor<br />
Low Profile<br />
Form Factor<br />
Low Profile<br />
Connectors<br />
4 Mini SAS (x4)<br />
SFF 8087 Internal<br />
Connectors<br />
2 Mini SAS (x4)<br />
SFF 8088 External<br />
Connectors<br />
2 Mini SAS (x4)<br />
SFF 8087 Internal<br />
Part Number<br />
ESAS-H30F-000<br />
Part Number<br />
ESAS-H380-000<br />
Part Number<br />
ESAS-H308-000<br />
attotech.com 716.691.1999<br />
2/11 Product features and specifications are subject to change without notice.
Data Sheet<br />
6Gb/s SAS/SATA RAID <strong>Adapters</strong><br />
ExpressSAS R60F<br />
ExpressSAS R680<br />
ExpressSAS R608<br />
ExpressSAS R644<br />
ATTO’s ExpressSAS 6Gb/s SAS/SATA RAID <strong>Adapters</strong> offer<br />
the fastest available connectivity to SAS or SATA storage<br />
with integrated RAID protection.<br />
Long-Standing RAID Experience<br />
Leveraging over 18 years of RAID technology development, ATTO’s family of ExpressSAS<br />
6Gb/s SAS/SATA RAID adapters feature the time-proven ATTO RAID Stack, DVRAID and<br />
CacheAssure, propietary technologies developed to provide the most robust RAIDbased<br />
connectivity solution in the industry.<br />
Flexible Connectivity Solutions<br />
With several port configuration options including 16 internal, 8 external, 8 internal, and 4<br />
external/4 internal, ExpressSAS 6Gb/s SAS/SATA RAID adapters are ideal for a wide variety<br />
of IT and digital media environments requiring high-performance and parity RAID<br />
protected data. ExpressSAS RAID adapters offer driver support for Windows®, Linux and<br />
Mac® OS X, providing a single connectivity solution for customers with heterogeneous<br />
operating system environments.<br />
Performance Engineered<br />
The ExpressSAS 6Gb/s SAS/SATA RAID adapter family allows users to instantly protect their<br />
critical data while enhancing performance. ATTO designs ExpressSAS RAID adapters to<br />
maintain full performance in degraded mode and to minimize downtime with 50% faster<br />
rebuilds, limiting exposure to a second drive failure. Exclusive latency management<br />
features like Advanced Data Streaming (ADS) Technology and DriveAssure minimize<br />
data transfer interruptions to ensure the highest level of consistent performance. These<br />
differentiating capabilities make ATTO the premier choice for high-performance hostbased<br />
RAID connectivity.<br />
Advanced Management Tools<br />
ATTO’s easy-to-use Configuration Tool features an intuitive GUI that simplifies RAID group<br />
configuration, management and monitoring. ATTO’s ExpressSAS RAID adapters offer the<br />
most advanced performance tuning capabilities and troubleshooting utilities, providing<br />
users with sophisticated diagnostics and the flexibility to control settings for specific<br />
applications.<br />
Technical Features<br />
• Port configurations include 16 internal,<br />
8 external, 8 internal, and 4 internal /<br />
4 external<br />
• 1200 MB/s per port/phy throughput in<br />
full-duplex mode<br />
• Features a high-performance x8 PCIe<br />
2.0 host interface<br />
• Low-profile form factor<br />
• SAS 2.0, SAS, SATA and SATA II<br />
connectivity<br />
• Supports up to 128 SAS/SATA devices<br />
• Exclusive Advanced Data Streaming<br />
(ADS) Technology, DriveAssure and<br />
CacheAssure<br />
• Data Recovery mode increases the<br />
probability of retrieving lost data from a<br />
failed drive<br />
• Disk and Tape support in one PCIe slot<br />
• Driver support for Windows®, Linux,<br />
and Mac® OS X<br />
• CacheAssure (option) for secure<br />
backup of data<br />
• RAID 0, 1, 4, 5, 6, 10, 40, 50, 60, JBOD<br />
and DVRAID<br />
attotech.com<br />
716.691.1999
6Gb/s SAS/SATA RAID <strong>Adapters</strong><br />
ExpressSAS R60F, R680, R608, R644<br />
Data Sheet<br />
Technical Specifications<br />
Applications<br />
ExpressSAS RAID adapters add high-performance RAID data protection to direct-attached SAS and SATA JBOD storage. They are an ideal connectivity solution for high-performance<br />
media and entertainment and general IT environments. ExpressSAS 6Gb/s SAS/SATA RAID adapters deliver affordable host-level RAID for high-bandwidth workflows such as digital<br />
content creation, streaming video, transactional databases, and email and Web servers.<br />
Advanced Data Streaming (ADS)<br />
Latency-management technology that controls the<br />
acceleration of data transfers to move large amounts of<br />
data faster and more efficiently.<br />
DriveAssure Technology<br />
Drive assessment and latency management technology<br />
that minimizes the likelihood of RAID groups becoming<br />
degraded or taken offline due to slow drives, ensuring<br />
uninterrupted access to data.<br />
CacheAssure Technology<br />
Flash-based protection module providing a<br />
maintenance-free solution that safeguards against the<br />
loss of cached data during a power or system failure.<br />
RAID Features and Functionality<br />
▪ SAS 2.0, SAS, SATA and SATA II support<br />
▪ RAID Levels 0, 1, 4, 5, 6, 10, 40, 50, 60, JBOD,<br />
DVRAID<br />
▪ ATTO RAID stack<br />
▪ Command coalescing<br />
▪ Staggered drive spin-up<br />
▪ RAID level migration<br />
▪ Hot swap with auto rebuild<br />
▪ Online performance metrics and event logs<br />
▪ Native command queuing<br />
▪ 512MB ECC protected cache memory<br />
▪ SES, SNMP and S.M.A.R.T. Support<br />
▪ Pass-through support for tape and tape devices<br />
▪ Configurable stripe size<br />
▪ Online capacity expansion<br />
▪ Global and dedicated hot spares<br />
▪ Automatic and tunable online rebuilds<br />
▪ N-way mirroring<br />
User Benefits<br />
▪ High performance host-based RAID for directattached<br />
storage<br />
▪ Four port configurations for flexible connectivity<br />
▪ Full performance in degraded or rebuild mode<br />
▪ Flash-based cache protection protects against lost<br />
data during power or system failure<br />
▪ More options for retrieving data from a failed drive<br />
with Data Recovery mode<br />
▪ 50% faster rebuilds<br />
▪ Efficient scalability with host-level RAID<br />
▪ Maintain high priority workflows with tunable<br />
rebuilds<br />
▪ RAID group partitioning for better management<br />
Management Tools<br />
▪ User-friendly GUI for quick and easy RAID setup<br />
▪ Command Line Interface for advanced functionality<br />
▪ ATTO Config Tool: BIOS-based RAID management<br />
and configuration utility<br />
Bus Specifications<br />
▪ x8 PCI Express 2.0 host interface<br />
External Connectivity<br />
▪ x4 Mini SAS connectors<br />
▪ Low profile form factor; full-height bracket included<br />
Operating System Support<br />
▪ Windows® Server 2003, 2008,<br />
▪ Windows XP, Vista, 7<br />
▪ SUSE Linux<br />
▪ Red Hat Linux<br />
▪ Mac ®OS X (10.4.x - 10.6.x)<br />
Agency Approvals<br />
▪ FCC Part 15, Subpart B, Class B<br />
▪ EN55024: 1998 + A1: 2001 + A2: 2003<br />
▪ EN55022: 2006, Class B<br />
Compliance<br />
▪ EN60950-1: 2001<br />
▪ RoHS-6<br />
Dimensions<br />
R60F<br />
▪ Length 8.638”, Height 2.846”<br />
R608/R680/R644<br />
▪ Length 6.600”, Height 2.713”<br />
Operating Temperature<br />
Hardware Environment<br />
▪ Temperature: 0-40° C<br />
▪ Humidity: 10 - 90% non-condensing<br />
Storage Environment<br />
▪ Temperature: -40°-70°C (-40°-157°F)<br />
▪ Humidity: 5 - 95% non-condensing<br />
Operating Voltage<br />
R60F<br />
▪ 18W (typical)<br />
R680/R608/R644<br />
▪ 9.6W (typical)<br />
Airflow<br />
▪ 150 lf/m (min) recommended<br />
Warranty<br />
▪ 3 Year<br />
ATTO ExpressSAS R60F ATTO ExpressSAS R680 ATTO ExpressSAS R608 ATTO ExpressSAS R644<br />
Ports 16 Internal 8 External 8 Internal 4 External/4 Internal<br />
Bus Characteristics x8 PCIe 2.0 x8 PCIe 2.0 x8 PCIe 2.0 x8 PCIe 2.0<br />
Form Factor Low Profile Low Profile Low Profile Low Profile<br />
Connectors<br />
4 Mini SAS (x4)<br />
SFF 8087 Internal<br />
2 Mini SAS (x4)<br />
SFF 8088 External<br />
2 Mini SAS (x4)<br />
SFF 8087 Internal<br />
1 Mini SAS (x4)<br />
SFF 8088 External<br />
1 Mini SAS (x4)<br />
SFF 8087 Internal<br />
Part Number<br />
With CacheAssure option<br />
ESAS-R60F-000<br />
ESAS-R60F-C00<br />
ESAS-R680-000<br />
ESAS-R680-C00<br />
ESAS-R608-000<br />
ESAS-R608-C00<br />
ESAS-R644-000<br />
ESAS-R644-C00<br />
attotech.com<br />
716.691.1999<br />
2/11 Product features and specifications are subject to change without notice.
Tech Sheet<br />
3Gb/s SAS/SATA RAID <strong>Adapters</strong><br />
ExpressSAS R30F<br />
ExpressSAS R380<br />
ExpressSAS R348<br />
ATTO’s ExpressSAS 3Gb/s SAS/SATA RAID <strong>Adapters</strong><br />
add high-performance parity RAID data protection<br />
to direct-attached SAS and SATA JBOD storage.<br />
Long-Standing RAID Experience<br />
Leveraging over 18 years of RAID technology development, ATTO’s family of ExpressSAS<br />
3Gb/s SAS/SATA RAID adapters feature the time-proven ATTO RAID Stack, DVRAID and<br />
DriveAssure, propietary technologies developed to provide the most robust RAID-based<br />
connectivity solution in the industry.<br />
Flexible Connectivity Solutions<br />
With several port configuration options including 16 internal, 8 external and a userselectable<br />
4 internal/4 external or 8 internal, ExpressSAS 3Gb/s SAS/SATA RAID adapters<br />
are ideal for a wide variety of IT and digital media environments requiring highperformance<br />
and parity RAID protected data. ExpressSAS RAID adapters offer driver<br />
support for Windows®, Linux and Mac® OS X, providing a single connectivity solution for<br />
customers with heterogeneous operating system environments.<br />
Performance Engineered<br />
The ExpressSAS 3Gb/s SAS/SATA RAID adapter family allows users to instantly protect their<br />
critical data without compromising performance. ATTO designs ExpressSAS RAID adapters<br />
to maintain full performance in degraded mode and to minimize downtime with 50%<br />
faster rebuilds, limiting exposure to a second drive failure. Exclusive latency management<br />
features like Advanced Data Streaming (ADS) Technology and DriveAssure minimize<br />
data transfer interruptions to ensure the highest level of consistent performance. These<br />
differentiating capabilities make ATTO the premier choice for high-performance hostbased<br />
RAID connectivity.<br />
Technical Features<br />
• Port configurations include 16 internal,<br />
8 external and user-selectable<br />
4 internal / 4 external or 8 internal<br />
• 600 MB/s per port/phy throughput in<br />
full-duplex mode<br />
• Features an x8 PCIe host interface<br />
• Low-profile form factor<br />
• SAS, SATA and SATA II connectivity<br />
• Supports up to 128 SAS/SATA devices<br />
• Exclusive Advanced Data Streaming<br />
(ADS) Technology and DriveAssure<br />
• Data Recovery mode increases the<br />
probability of retrieving lost data from<br />
a failed drive<br />
• Disk and Tape support in one PCIe slot<br />
• Driver support for Windows®, Linux,<br />
and Mac® OS X<br />
• RAID 0, 1, 4, 5, 6, 10, 40, 50, 60, JBOD<br />
and DVRAID®<br />
• 3-year standard product warranty<br />
Advanced Management Tools<br />
ATTO’s easy-to-use Configuration Tool features an intuitive GUI that simplifies RAID group<br />
configuration, management and monitoring. ATTO’s ExpressSAS RAID adapters offer the<br />
most advanced performance tuning capabilities and troubleshooting utilities, providing<br />
users with sophisticated diagnostics and the flexibility to control settings for specific<br />
applications.<br />
attotech.com<br />
716.691.1999
3Gb/s SAS/SATA RAID <strong>Adapters</strong><br />
ExpressSAS R30F, R380, R348<br />
Tech Sheet<br />
Technical Specifications<br />
Applications<br />
ExpressSAS RAID adapters add high-performance RAID data protection to direct-attached SAS and SATA JBOD storage. They are an ideal connectivity solution for high-performance<br />
media and entertainment and general IT environments. ExpressSAS 3Gb/s SAS/SATA RAID adapters deliver affordable host-level RAID for high-bandwidth workflows such as digital<br />
content creation, streaming video, transactional databases, and email and Web servers.<br />
Advanced Data Streaming (ADS)<br />
Latency-management technology that controls the<br />
acceleration of data transfers to move large amounts of<br />
data faster and more efficiently.<br />
DriveAssure Technology<br />
Drive assessment and latency management technology<br />
that minimizes the likelihood of RAID groups becoming<br />
degraded or taken offline due to slow drives, ensuring<br />
uninterrupted access to data.<br />
RAID Features and Functionality<br />
▪ SAS, SATA and SATA II support<br />
▪<br />
▪<br />
▪<br />
▪<br />
▪<br />
▪<br />
▪<br />
▪<br />
▪<br />
▪<br />
▪<br />
▪<br />
▪<br />
▪<br />
▪<br />
▪<br />
▪<br />
RAID Levels 0, 1, 4, 5, 6, 10, 40, 50, 60, JBOD,<br />
DVRAID<br />
ATTO RAID stack<br />
Command coalescing<br />
Support for staggered drive spin-up<br />
RAID level migration<br />
Hot swap with auto rebuild<br />
Online performance metrics and event logs<br />
Native command queuing<br />
256/512MB ECC protected cache memory<br />
SES, SNMP and S.M.A.R.T. Support<br />
DVRAID for high-bandwidth video environments<br />
Pass-through support for tape and tape devices<br />
Configurable stripe size<br />
Online capacity expansion<br />
Global and dedicated hot spares<br />
Automatic and tunable online rebuilds<br />
N-way mirroring<br />
User Benefits<br />
▪ High performance host-based RAID for directattached<br />
storage<br />
▪ Three port configurations for flexible connectivity<br />
▪ Full performance in degraded or rebuild mode<br />
▪ More options for retrieving data from a failed drive<br />
with Data Recovery mode<br />
▪ Affordable and scalable storage expansion<br />
alternative to RAID arrays<br />
▪ 50% faster rebuilds<br />
▪ Maintain high priority workflows with tunable<br />
rebuilds<br />
▪ RAID group partitioning for better management<br />
Management Tools<br />
▪ User-friendly GUI for quick and easy RAID setup<br />
▪ Command Line Interface for advance functionality<br />
▪<br />
ATTO Config Tool: BIOS-based RAID management<br />
and configuration utility<br />
Bus Specifications<br />
▪ x8 PCI Express host interface<br />
External Connectivity<br />
▪ x4 Mini SAS connectors<br />
▪ Low profile form factor; full-height bracket included<br />
▪<br />
External LEDs for on-line & speed status for each<br />
port<br />
Operating System Support<br />
▪ Windows® Server 2003, 2008,<br />
▪ Windows XP, Vista, 7<br />
▪ SUSE Linux<br />
▪ Red Hat Linux<br />
▪ Mac® OS X (10.4.x - 10.6.x)<br />
Agency Approvals<br />
▪ FCC Part 15, Subpart B, Class B<br />
▪ CE Mark: CISPR 22:2002<br />
▪ EN55022: 2006, Class B<br />
Compliance<br />
▪ RoHS<br />
Dimensions<br />
R30F<br />
▪ Length 8.640”, Height 2.900”<br />
R380/R348<br />
▪ Length 6.600”, Height 2.731”<br />
Operating Temperature<br />
Hardware Environment<br />
▪ Temperature: 0-40°C (32°-104° F) - R380/R348<br />
▪ Temperature: 0-60°C (32°-104° F) - R30F<br />
▪ Humidity: 5 - 95% non-condensing<br />
Storage Environment<br />
▪ Temperature: -40°-70°C (-40°-157°F)<br />
▪ Humidity: 5 - 95% non-condensing<br />
Operating Voltage<br />
R30F<br />
▪ 17W (typical)<br />
R380/R348<br />
▪ 13W (typical)<br />
Airflow<br />
▪ 150 lf/m (min) recommended<br />
Warranty<br />
▪ 3 Year<br />
ATTO ExpressSAS R30F<br />
ATTO ExpressSAS R380<br />
ATTO ExpressSAS R348<br />
Ports<br />
16 Internal<br />
Ports<br />
8 External<br />
Ports<br />
User Selectable<br />
4 Ext/4 Int or 8 Int<br />
Bus Characteristics<br />
x8 PCIe<br />
Bus Characteristics<br />
x8 PCIe<br />
Bus Characteristics<br />
x8 PCIe<br />
Form Factor<br />
Low Profile<br />
Form Factor<br />
Low Profile<br />
Form Factor<br />
Low Profile<br />
Connectors<br />
4 Mini SAS (x4)<br />
SFF 8087 Internal<br />
Connectors<br />
2 Mini SAS (x4)<br />
SFF 8088 External<br />
Connectors<br />
1 Mini SAS (x4)<br />
SFF 8088 External,<br />
2 Mini SAS (x4)<br />
SFF 8087 Internal<br />
Part Number<br />
ESAS-R30F-000<br />
Part Number<br />
ESAS-R380-000<br />
Part Number<br />
ESAS-R348-000<br />
attotech.com<br />
716.691.1999<br />
2/11 Product features and specifications are subject to change without notice.
Tech Sheet<br />
Ultra320 SCSI <strong>Host</strong> Bus <strong>Adapters</strong><br />
ExpressPCI UL5D LP<br />
ExpressPCI UL5D<br />
ExpressPCI UL4D<br />
The ATTO ExpressPCI SCSI host bus adapter family complements<br />
high-performance Direct Attached Storage (DAS) configurations in<br />
multiple environments by providing a flexible and reliable storage<br />
solution for servers and workstations.<br />
Industry Proven<br />
ATTO ExpressPCI Ultra320 SCSI host bus adapters offer high-performance connectivity to<br />
tape and external storage. The UL5D LP, UL5D and UL4D SCSI HBAs help users meet the<br />
demands of a wide variety of high-bandwidth applications in Mac®, Windows® or Linux<br />
environments.<br />
Performance Engineered<br />
ExpressPCI SCSI host bus adapters feature a PCI Express or PCI-X interconnect and boast<br />
speeds of up to 640MB/s. With exclusive Advanced Data Streaming (ADS TM ) technology,<br />
the UL5D LP, UL5D and UL4D effectively manage latency for fast and efficient data<br />
transfers. ADS Technology ensures best-in-industry data transfers by controlling the<br />
acceleration of data to maintain the highest consistent performance. The combination of<br />
Ultra320 SCSI and PCI Express makes ExpressPCI HBAs ideal for workstations running<br />
bandwidth-intensive applications such as video editing, messaging and databases.<br />
Easy to Use<br />
ExpressPCI SCSI host bus adapters come with ATTO’s factory-preset configurations for outof-the-box<br />
plug and play operation. The ATTO Configuration Tool, featuring an easy-to-use<br />
GUI, simplifies the installation, management and monitoring of the HBA. The Configuration<br />
Tool enables the best possible performance by allowing users to modify the adapter’s<br />
default settings.<br />
Technical Features<br />
• Dual <strong>Channel</strong> (2 internal, 2 external)<br />
Ultra320 SCSI<br />
• Up to 320MB/s per channel throughput<br />
in full-duplex mode<br />
• x4 PCI Express or 64-bit,133MHz PCI-X<br />
connections<br />
• Driver support for Mac®, Windows®,<br />
Linux, and more<br />
• Exclusive Advanced Data Streaming<br />
(ADS) Technology<br />
• ATTO Configuration Tool for customized<br />
performance settings<br />
• Low voltage differential<br />
• Supports up to 30 SCSI bus IDs<br />
• Up to 12 meter cable lengths<br />
• 3-year standard product warranty<br />
• Low power consumption<br />
attotech.com 1.716.691.1999
Ultra320 SCSI <strong>Host</strong> Bus <strong>Adapters</strong><br />
ExpressPCI UL5D LP, UL5D, UL4D<br />
Tech Sheet<br />
Technical Specifications<br />
Applications<br />
ATTO ExpressPCI SCSI host bus adapters are specifically engineered for reliable storage connectivity and high-performance for data-intensive environments such as HD video<br />
editing, transactional database applications and large server farms. ExpressPCI SCSI HBAs are a field tested and time proven connectivity solution for direct attached storage<br />
environments.<br />
Advanced Data Streaming (ADS)<br />
Latency-management technology that controls the<br />
acceleration of data transfers to move large<br />
amounts of data faster and more efficiently.<br />
Key Features<br />
▪ Low voltage differential (LVD) signaling<br />
▪ Tagged command queuing support<br />
▪<br />
▪<br />
▪<br />
▪<br />
▪<br />
▪<br />
▪<br />
▪<br />
▪<br />
▪<br />
Backwards compatible with Ultra160, Ultra2<br />
and Ultra/WIDE<br />
Dynamic bus rescan<br />
Double transition clocking<br />
Domain validation and packetization<br />
Quick Arbitration Select (QAS)<br />
Bootable from attached disks<br />
On-board termination<br />
Flash ROM for easy field upgrades<br />
Cyclical Redundancy Checking (CRC)<br />
Optimized SCSI-3 algorithms<br />
Bus Specifications<br />
UL5D LP, UL5D<br />
▪ x4 PCI Express<br />
▪ Supports PCI Express Base and CEM Spec 1.0a<br />
▪ PCI Express to PCI/PCI-X Bridge spec 1.0<br />
UL4D<br />
▪ 64-bit/133MHz PCI-X<br />
▪ PCI-X 1.0a compliant<br />
▪ PCI 2.2 and PCI 99 compliant<br />
Management Tools<br />
▪ ATTO Config Tool (w/GUI) BIOS-based<br />
management and configuration utility<br />
Operating System Support<br />
▪ Windows® Server 2003, 2008<br />
▪ Windows XP, Vista, 7<br />
▪ Mac OS® X (10.4.x - 10.6.x)<br />
▪ SUSE Linux<br />
▪ Red Hat Linux<br />
▪ Novell Netware® v6.5<br />
Agency Approvals<br />
▪ FCC Part 15, Subpart B, Class A<br />
▪ CE Mark: CISPR 22/EN 55022, Class A<br />
Compliance<br />
▪ RoHS<br />
Dimensions<br />
UL5D LP<br />
▪ Length 6.6”, Height 2.713”<br />
UL5D<br />
▪ Length 7.5”, Height 4.376”<br />
UL4D<br />
▪ Length 6.521”, Height 4.450”<br />
Operating Temperature<br />
Hardware Environment<br />
▪ Temperature: 0-40° C<br />
▪ Humidity: 10 - 90% non-condensing<br />
Operating Voltage<br />
UL5D LP<br />
▪ 0.7 Amps @ +3.3 VDC<br />
▪ 0.6 Amps @ +12 VDC<br />
UL5D<br />
▪ 1.61 typical/2.03 max Amps @ +3.3 VDC<br />
▪ 0.6 5 typical/1.46 Amps @ +12 VDC<br />
UL4D<br />
▪ 0.75 typical/2.0 max Amps @ +5.0 VDC<br />
▪ 0.0 5 Amps @ +12 VDC<br />
Reliability (MTBF)<br />
UL5D LP<br />
▪ 675,000 hours<br />
UL5D<br />
▪ 675,000 hours<br />
UL4D<br />
▪ 150,000 hours<br />
Airflow<br />
▪ 100 lf/m (min) recommended<br />
Warranty<br />
▪ 3 Year<br />
ATTO ExpressPCI UL5D LP<br />
ATTO ExpressPCI UL5D<br />
ATTO ExpressPCI UL4D<br />
Power<br />
0.7 Amps @ + 3.3 VDC<br />
0.6 Amps @ + 12.0 VDC<br />
Power<br />
1.61 Amps@ + 3.3 VDC<br />
0.65 Amps @ + 12.0 VDC<br />
Power<br />
0.75 Amps @+5.0 VDC<br />
0.05 Amps @+12.0 VDC<br />
Dimensions Length = 6.6”<br />
Height = 2.713”<br />
Dimensions Length = 7.5”<br />
Height = 4.376”<br />
Dimensions Length = 6.521”<br />
Height = 4.450”<br />
Reliability<br />
MTBF = 675,000 Hours<br />
MTTR < 15 Minutes<br />
Reliability<br />
MTBF = 675,000 Hours<br />
MTTR < 15 Minutes<br />
Reliability<br />
MTBF = 150,000 Hours<br />
MTTR < 15 Minutes<br />
Part Number<br />
EPCI-UL5D-L00<br />
Part Number<br />
EPCI-UL5D-0R0<br />
Part Number<br />
EPCI-UL4D-0R0<br />
attotech.com 1.716.691.1999<br />
2/11 Product features and specifications are subject to change without notice.