<strong>Celerity</strong> <strong>Fibre</strong> <strong>Channel</strong> <strong>Host</strong> <strong>Adapters</strong><br />

<strong>Selection</strong> <strong>Guide</strong><br />

Product<br />

Features<br />

<strong>Celerity</strong> <strong>Host</strong> <strong>Adapters</strong><br />

FC-84EN FC-82EN FC-81EN FC-44ES FC-42ES FC-41ES FC-42XS FC-41XS<br />

<strong>Fibre</strong> <strong>Channel</strong> Ports 4 2 1 4 2 1 2 1<br />

Maximum Data Rate 8Gb 8Gb 8Gb 4Gb 4Gb 4Gb 4Gb 4Gb<br />

Maximum Transfer Rate<br />

(full duplex)<br />

Maximum Transfer Rate<br />

(half duplex)<br />

6.4 GB/s 3.2 GB/s 1.6 GB/s 3.2 GB/s 1.6 GB/s 800 MB/s 1.6 GB/s 800 MB/s<br />

3.2 GB/s 1.6 GB/s 800 MB/s 1.6 GB/s 800 MB/s 400 MB/s 800 MB/s 400 MB/s<br />

Bus Type PCIe 2.0 PCIe 2.0 PCIe 2.0 PCIe PCIe PCIe PCI-X PCI-X<br />

Bus Characteristics x8 x8 x8 x8 x4 x4<br />

64-bit, 133<br />

MHz<br />

64-bit, 133<br />

MHz<br />

Optical Interface SFP+LC SFP+LC SFP+LC SFP LC SFP LC SFP LC SFP LC SFP LC<br />

Maximum Cable Length<br />

Low-Profile Form<br />

Factor<br />

300m - 2Gb<br />

150m - 4Gb<br />

50m - 8Gb<br />

300m - 2Gb<br />

150m - 4Gb<br />

50m - 8Gb<br />

300m - 2Gb<br />

150m - 4Gb<br />

50m - 8Gb<br />

300m - 2Gb<br />

150m - 4Gb<br />

300m - 2Gb<br />

150m - 4Gb<br />

300m - 2Gb<br />

150m - 4Gb<br />

300m - 2Gb<br />

150m - 4Gb<br />

300m - 2Gb<br />

150m - 4Gb<br />

Advanced Data<br />

Streaming (ADS)<br />

Software RAID Support<br />

Developer's Kit (Target<br />

Mode & API)<br />

Windows®<br />

Linux® (Red Hat, SUSE)<br />

Mac® OS X<br />

VMware® ESX Server<br />

Novell® Netware<br />

Solaris®<br />

FreeBSD®<br />

RoHS Compliant<br />

9/09


Tech Sheet<br />

8Gb/s <strong>Fibre</strong> <strong>Channel</strong> <strong>Host</strong> Bus <strong>Adapters</strong><br />

<strong>Celerity</strong> FC-84EN<br />

<strong>Celerity</strong> FC-82EN<br />

<strong>Celerity</strong> FC-81EN<br />

ATTO’s <strong>Celerity</strong> 8Gb/s <strong>Fibre</strong> <strong>Channel</strong> <strong>Host</strong> Bus <strong>Adapters</strong><br />

provide the highest performing SAN storage connectivity for<br />

media and entertainment and general IT workflows.<br />

Industry Proven Technology<br />

ATTO has over 15 years of experience developing high performance and reliable <strong>Fibre</strong><br />

<strong>Channel</strong> storage connectivity to deliver first-to-market solutions to customers. <strong>Celerity</strong> host<br />

bus adapters are consistently the highest performing HBAs for video editing, digital audio,<br />

video on demand, or database applications. The integrated family of <strong>Celerity</strong> 8Gb/s <strong>Fibre</strong><br />

<strong>Channel</strong> host bus adapters boast an extensive list of customer design wins and<br />

certifications with respected industry partners.<br />

Flexible Connectivity Solutions<br />

With single-, dual- and quad-channel configurations, <strong>Celerity</strong> 8Gb/s <strong>Fibre</strong> <strong>Channel</strong> HBAs are<br />

an ideal solution for users looking to achieve the highest I/O and data throughput for<br />

advanced video and enterprise-class IT applications. <strong>Celerity</strong> 8Gb/s host bus adapters offer<br />

driver support for Windows®, Linux, Mac® OS X and VMware®, providing a single<br />

connectivity solution for customers with heterogeneous operating system environments.<br />

Performance Engineered<br />

<strong>Celerity</strong> HBAs are designed to provide fast, redundant and highly available connectivity to<br />

<strong>Fibre</strong> <strong>Channel</strong> storage, and are engineered to manage latency for real-time applications.<br />

ATTO’s exclusive Advanced Data Streaming (ADS) technology provides controlled<br />

acceleration of data to deliver the highest consistent performance and reliable data<br />

transfers. ATTO pays close attention to detail in board design and signal integrity to<br />

minimize transmission errors and data corruption. Specialized <strong>Fibre</strong> <strong>Channel</strong> drivers with<br />

support for multiple OS platforms and OEM-specific solutions such as target mode and<br />

multipathing, make ATTO the premier choice for high-performance <strong>Fibre</strong> <strong>Channel</strong> SAN<br />

connectivity.<br />

Advanced Management Tools<br />

ATTO’s easy-to-use Configuration Tool features an intuitive GUI that simplifies the<br />

installation, management and monitoring of the host bus adapter. With advanced<br />

troubleshooting and performance tuning capabilities, <strong>Celerity</strong> HBAs provide users with<br />

sophisticated diagnostics and the flexibility to control settings for specific applications.<br />

Technical Features<br />

• Single-, Dual- and Quad-<strong>Channel</strong><br />

configurations<br />

• 1600 MB/s per channel throughput in full<br />

-duplex mode<br />

• Driver support for Windows®, Linux, Mac®<br />

OS X, VMware® and more<br />

• Exclusive Advanced Data Streaming<br />

(ADS) Technology<br />

• ATTO Configuration Tool for customized<br />

performance settings<br />

• Proven interoperable with leading<br />

storage hardware and software vendors<br />

• Complete SAN connectivity when<br />

combined with ATTO <strong>Fibre</strong>Connect<br />

8Gb/s <strong>Fibre</strong> <strong>Channel</strong> switches<br />

• Support for N_Port ID Virtualization and<br />

Virtual Fabric<br />

• Target mode support<br />

• Low power consumption<br />

• 3-year standard product warranty<br />

MultiPath Director<br />

High-availability storage connectivity<br />

solution for Media and Entertainment<br />

• Multiple paths to storage for improved<br />

data integrity and reliability<br />

• High-performance shared storage for<br />

workgroups<br />

• Load-balancing and failover in<br />

heterogeneous OS environments<br />

attotech.com 716.691.1999


8Gb/s <strong>Fibre</strong> <strong>Channel</strong> <strong>Host</strong> Bus <strong>Adapters</strong><br />

<strong>Celerity</strong> FC-84EN, FC-82EN, FC-81EN<br />

Tech Sheet<br />

Technical Specifications<br />

Applications<br />

<strong>Celerity</strong> <strong>Fibre</strong> <strong>Channel</strong> host bus adapters deliver high-performance and reliable connectivity solutions for the most demanding storage environments, including digital content<br />

creation, tape streaming and backup, rich content delivery, server clustering, and complex databases. <strong>Celerity</strong> HBAs enable users to achieve the ultimate in I/O performance for<br />

real-time and transactional applications.<br />

Advanced Data Streaming (ADS)<br />

Latency-management technology that controls the<br />

acceleration of data transfers to move large<br />

amounts of data faster and more efficiently.<br />

Key Features<br />

▪ Auto Negotiation to 8Gb, 4Gb and 2Gb devices<br />

▪ Supports arbitrated loop, point-to-point and<br />

direct fabric/switch attach<br />

▪ ANSI <strong>Fibre</strong> <strong>Channel</strong>: FC-FS, FCP, FC-AL, FC-AL2,<br />

FC-PLDA, FC-FLA<br />

▪ Flash ROM for easy field upgrades<br />

▪ FC Class 3 Support<br />

▪ Buffer Credits: 41<br />

▪ Software RAID support with ATTO’s Power<br />

Center software<br />

▪ Pluggable optical LC SFP+<br />

▪ Initiator and target mode (OEM) support<br />

▪ Supports Windows FDMI and WMI<br />

▪ Supports NPIV and Virtual Fabric<br />

User Benefits<br />

▪ Superior performance for enterprise<br />

applications<br />

▪ Low power consumption<br />

▪ Quad port card maximizes usage of server slots<br />

▪ Increased switch port availability<br />

▪ Reduced cost per MB of data transferred<br />

▪ Seamless integration into existing FC SANs<br />

▪ Support for virtualized server environments<br />

▪ Extensive certification with SAN infrastructure<br />

components<br />

Management Tools<br />

▪ ATTO Config Tool (w/GUI) BIOS-based<br />

management and configuration utility<br />

Bus Specifications<br />

▪ x8 PCI Express 2.0 host interface<br />

▪ Supports PCI Express Base Spec 2.0<br />

▪ Supports PCI Express CEM Spec 2.0<br />

▪ PCI Hot Plug spec 1.0<br />

External Connectivity<br />

▪ Standard size brackets installed with spare low<br />

profile brackets for FC-82EN, FC-81EN<br />

▪ Single (1), Dual (2) or Quad (4) pluggable 8Gb<br />

optical LC SFP+ modules included<br />

▪ External LEDs for on-line and speed status for<br />

each port<br />

Operating System Support<br />

▪ Windows® Server 2003, 2008<br />

▪ Windows XP, Vista, 7<br />

▪ SUSE Linux<br />

▪ Red Hat Linux<br />

▪ Mac OS® X 10.4.x & later<br />

▪ VMware ESX Server® 3.5 - 4.x<br />

▪ VMware ESXi Server® 4.x - 5.x<br />

Agency Approvals<br />

▪ FCC Part 15, Subpart B, Class A (FC-84EN),<br />

Class B (FC-82EN & FC-81EN )<br />

▪ EN55024: 1998A + A1: 2001 & A2: 2003<br />

▪ EN60825-1: 1994-2: 2004<br />

▪ EN55022: 2006, Class A FC-84EN),<br />

Class B (FC-82EN & FC-81EN )<br />

Compliance<br />

▪ EN60950-1: 2001<br />

▪ RoHS<br />

Dimensions<br />

FC-84EN<br />

▪ Length 6.525”, Height 3.987”<br />

FC-82EN, FC-81EN<br />

▪ Length 6.600”, Height 2.731”<br />

Operating Temperature<br />

Hardware Environment<br />

▪ Temperature: 0-40° C<br />

▪ Humidity: 10 - 90% non-condensing<br />

Storage Environment<br />

▪ Temperature: -40°-70°C (-40°-157°F)<br />

▪ Humidity: 5 - 95% non-condensing<br />

Operating Voltage<br />

FC-84EN<br />

▪ 7.8W (typical)<br />

FC-82EN<br />

▪ 5.9W (typical)<br />

FC-81EN<br />

▪ 5.3W (typical)<br />

Airflow<br />

▪ 100 lf/m (min) recommended<br />

Warranty<br />

▪ 3 Year<br />

ATTO <strong>Celerity</strong> FC-84EN<br />

Ports 4<br />

Bus Characteristics x8 PCIe 2.0<br />

Form Factor<br />

Max. Transfer Rate<br />

(Full duplex)<br />

(Half duplex)<br />

Full Height<br />

6.4GB/s<br />

3.2GB/s<br />

ATTO <strong>Celerity</strong> FC-82EN<br />

Ports 2<br />

Bus Characteristics x8 PCIe 2.0<br />

Form Factor<br />

Max. Transfer Rate<br />

(Full duplex)<br />

(Half duplex)<br />

Low Profile<br />

3.2GB/s<br />

1.6GB/s<br />

ATTO <strong>Celerity</strong> FC-81EN<br />

Ports 1<br />

Bus Characteristics x8 PCIe 2.0<br />

Form Factor<br />

Max. Transfer Rate<br />

(Full duplex)<br />

(Half duplex)<br />

Low Profile<br />

1.6GB/s<br />

800MB/s<br />

Part Number<br />

CTFC-84EN-000<br />

Part Number<br />

CTFC-82EN-000<br />

Part Number<br />

CTFC-81EN-000<br />

attotech.com 716.691.1999<br />

9/11 Product features and specifications are subject to change without notice.


Tech Sheet<br />

4Gb/s PCIe <strong>Fibre</strong> <strong>Channel</strong> <strong>Host</strong> Bus <strong>Adapters</strong><br />

<strong>Celerity</strong> FC-44ES<br />

<strong>Celerity</strong> FC-42ES<br />

<strong>Celerity</strong> FC-41ES<br />

ATTO’s <strong>Celerity</strong> 4Gb/s <strong>Fibre</strong> <strong>Channel</strong> <strong>Host</strong> Bus <strong>Adapters</strong><br />

provide efficient data transfers for editing and producing<br />

content in media and entertainment and general IT workflows.<br />

Industry Proven Technology<br />

ATTO has over 15 years of experience developing high performance and reliable <strong>Fibre</strong><br />

<strong>Channel</strong> storage connectivity to deliver first-to-market solutions to customers. <strong>Celerity</strong> host<br />

bus adapters are consistently the highest performing HBAs for video editing, digital audio,<br />

video on demand, or database applications. The integrated family of <strong>Celerity</strong> 4Gb/s PCIe<br />

<strong>Fibre</strong> <strong>Channel</strong> host bus adapters boast an extensive list of design wins and certifications<br />

with respected industry partners.<br />

Flexible Connectivity Solutions<br />

With single-, dual- and quad-channel configurations, <strong>Celerity</strong> 4Gb/s PCIe <strong>Fibre</strong> <strong>Channel</strong><br />

HBAs are an ideal solution for users looking to achieve the highest I/O and data throughput<br />

for high-bandwidth workflows. <strong>Celerity</strong> 4Gb/s PCIe host bus adapters offer driver support<br />

for Windows®, Linux, Mac® OS X and VMware®, providing a single connectivity solution for<br />

customers with heterogeneous operating system environments.<br />

Performance Engineered<br />

<strong>Celerity</strong> HBAs are designed to provide fast, redundant and highly available connectivity to<br />

storage, and are engineered to manage latency for real-time applications. ATTO’s exclusive<br />

Advanced Data Streaming (ADS) technology provides controlled acceleration of data to<br />

deliver the highest consistent performance and reliable data transfers. ATTO pays close<br />

attention to detail in board design and signal integrity to minimize transmission errors and<br />

data corruption. Specialized <strong>Fibre</strong> <strong>Channel</strong> drivers with support for multiple OS platforms<br />

and OEM-specific solutions such as target mode and multipathing, make ATTO the premier<br />

choice for high-performance <strong>Fibre</strong> <strong>Channel</strong> SAN connectivity.<br />

Technical Features<br />

• Single-, Dual- and Quad-<strong>Channel</strong><br />

configurations<br />

• 800 MB/s per channel throughput in fullduplex<br />

mode<br />

• Available in a low-profile form factor<br />

• Driver support for Windows®, Linux, Mac®<br />

OS X, VMware® and more<br />

• Exclusive Advanced Data Streaming<br />

(ADS) Technology<br />

• ATTO Configuration Tool for customized<br />

performance settings<br />

• Proven interoperable with leading<br />

storage hardware and software vendors<br />

• Complete SAN connectivity when<br />

combined with ATTO <strong>Fibre</strong>Connect<br />

8Gb/s <strong>Fibre</strong> <strong>Channel</strong> switches<br />

• Target mode support<br />

• Low power consumption<br />

• 3-year standard product warranty<br />

Advanced Management Tools<br />

ATTO’s easy-to-use Configuration Tool features an intuitive GUI that simplifies the<br />

installation, management and monitoring of the host bus adapter. With advanced<br />

troubleshooting and performance tuning capabilities, <strong>Celerity</strong> HBAs provide users with<br />

sophisticated diagnostics and the flexibility to control settings for specific applications.<br />

attotech.com 1.716.691.1999


4Gb/s PCIe <strong>Fibre</strong> <strong>Channel</strong> <strong>Host</strong> Bus <strong>Adapters</strong><br />

<strong>Celerity</strong> FC-44ES, FC-42ES, FC-41ES<br />

Tech Sheet<br />

Technical Specifications<br />

Applications<br />

<strong>Celerity</strong> <strong>Fibre</strong> <strong>Channel</strong> host bus adapters deliver high-performance and reliable connectivity solutions for the most demanding storage environments, including digital content<br />

creation, tape streaming and backup, rich content delivery, server clustering, and complex databases. <strong>Celerity</strong> HBAs enable users to achieve the ultimate in I/O performance for<br />

real-time and transactional applications.<br />

Advanced Data Streaming (ADS)<br />

Latency-management technology that controls the<br />

acceleration of data transfers to move large<br />

amounts of data faster and more efficiently.<br />

Key Features<br />

▪ Auto Negotiation to 4Gb, 2Gb and 1Gb devices<br />

▪ Supports arbitrated loop, point-to-point and<br />

direct fabric/switch attach<br />

▪ ANSI <strong>Fibre</strong> <strong>Channel</strong>: FC-PH, FC-FCP, FC-AL, FC-<br />

AL2, FC-PLDA, FC-FLA<br />

▪ Flash ROM for easy field upgrades<br />

▪ FC Class 3 Support<br />

▪ Buffer Credits: 8 @ 512 Bytes; 8 @ 2KB<br />

▪ Software RAID support with ATTO’s Power<br />

Center software<br />

▪ Initiator and target mode (OEM) support<br />

▪ Supports Windows FDMI and WMI<br />

▪ Local management and diagnostics<br />

User Benefits<br />

▪ High performance and scalable connectivity<br />

▪ Optimized for video applications<br />

▪ Low power consumption<br />

▪ Seamless integration into existing FC SANs<br />

▪ Support for virtualized server environments<br />

▪ Ease of use and sophisticated management<br />

capabilities<br />

▪ Extensive certifications with SAN infrastructure<br />

components<br />

Management Tools<br />

▪ ATTO Config Tool (w/GUI) BIOS-based<br />

management and configuration utility<br />

Bus Specifications<br />

▪ x8 (FC-44ES) and x4 (FC-42ES, FC-41ES) PCI<br />

Express host interface<br />

▪ Supports PCI Express Base Spec 1.0a<br />

▪ Supports PCI Express CEM Spec 1.0a<br />

▪ PCI Express to PCI/PCI-X bridge Spec 1.0<br />

External Connectivity<br />

▪ Standard size brackets installed with spare low<br />

profile brackets for FC-42ES, FC-41ES<br />

▪ Single (1), Dual (2) or Quad (4) pluggable 4Gb<br />

optical LC SFP modules included<br />

▪ External LEDs for on-line and speed status for<br />

each port<br />

Operating System Support<br />

▪ Windows® Server 2003, 2008,<br />

▪ Windows XP, Vista, 7<br />

▪ SUSE Linux<br />

▪ Red Hat Linux<br />

▪ Mac ®OS X (10.4.x - 10.6.x)<br />

▪ VMware® ESX Server 3.5<br />

▪ Novell Netware<br />

▪ Solaris 9 & 10<br />

Agency Approvals<br />

▪ FCC Part 15, Class B<br />

▪ CISPR 22:2002<br />

▪ EN55022: 2002, Class B<br />

Compliance<br />

▪ RoHS<br />

Dimensions<br />

FC-44ES<br />

▪ Length 6.600”, Height 3.987”<br />

FC-42ES, FC-41ES<br />

▪ Length 5.600”, Height 2.712”<br />

Operating Temperature<br />

Hardware Environment<br />

▪ Temperature: 0-45°C (32°-113°F)<br />

▪ Humidity: 5 - 95% non-condensing<br />

Storage Environment<br />

▪ Temperature: -40°-70°C (-40°-157°F)<br />

▪ Humidity: 5 - 95% non-condensing<br />

Operating Voltage<br />

FC-44ES<br />

▪ 12V@2.1A max, 3.3V@3.0A max<br />

FC-42ES<br />

▪ 12V@0.4A max, 3.3V@1.5A max<br />

FC-41ES<br />

▪ 12V@0.4A max, 3.3V@1.0A max<br />

Airflow<br />

▪ 100 lf/m (min) recommended<br />

Warranty<br />

▪ 3 Year<br />

ATTO <strong>Celerity</strong> FC-44ES<br />

Ports 4<br />

ATTO <strong>Celerity</strong> FC-42ES<br />

Ports 2<br />

ATTO <strong>Celerity</strong> FC-41ES<br />

Ports 1<br />

Bus Characteristics<br />

x8 PCIe<br />

Bus Characteristics<br />

x4 PCIe<br />

Bus Characteristics<br />

x4 PCIe<br />

Form Factor<br />

Full Height<br />

Form Factor<br />

Low Profile<br />

Form Factor<br />

Low Profile<br />

Max. Transfer Rate<br />

(Full duplex)<br />

(Half duplex)<br />

3.2GB/s<br />

1.6GB/s<br />

Max. Transfer Rate<br />

(Full duplex)<br />

(Half duplex)<br />

1.6GB/s<br />

800MB/s<br />

Max. Transfer Rate<br />

(Full duplex)<br />

(Half duplex)<br />

800MB/s<br />

400MB/s<br />

Part Number<br />

CTFC-44ES-000<br />

Part Number<br />

CTFC-42ES-000<br />

Part Number<br />

CTFC-41ES-000<br />

attotech.com 1.716.691.1999<br />

2/11 Product features and specifications are subject to change without notice.


Tech Sheet<br />

6Gb/s SAS/SATA <strong>Host</strong> Bus <strong>Adapters</strong><br />

ExpressSAS H6F0<br />

ExpressSAS H60F<br />

ExpressSAS H680<br />

ExpressSAS H608<br />

ExpressSAS H644<br />

ATTO’s first-to-market ExpressSAS 6Gb/s SAS/SATA <strong>Host</strong><br />

Bus <strong>Adapters</strong> boast the highest available SAS and SATA<br />

performance for Direct Attached Storage infrastructures.<br />

Industry Proven Technology<br />

The ExpressSAS 6Gb/s host bus adapter product line was the first 6Gb/s-based family of<br />

HBAs available in the market. ExpressSAS 6Gb/s host bus adapters double the performance<br />

of 3Gb/s SAS/SATA host bus adapters and work seamlessly with a wide array of 3rd party<br />

products, including HDDs and SSDs, tape drives and many other SAS and SATA<br />

infrastructure products.<br />

Flexible Connectivity Solutions<br />

ExpressSAS 6Gb/s SAS/SATA HBAs are available in the widest selection of port<br />

configurations, providing the most flexible connectivity to SAS/SATA storage. With 8<br />

external, 8 internal, 4 external/4 internal, or a two-host-adapters-in-one configuration with<br />

16 external or 16 internal ports, users benefit from efficient scalability and more options<br />

from which to choose the best SAS/SATA HBA for their application.<br />

Performance Engineered<br />

ExpressSAS 6Gb/s host bus adapters combine 6Gb/s SAS speeds and x8 PCI Express 2.0<br />

with powerful hardware and software elements to manage latency in real-time<br />

environments. Exclusive Advanced Data Streaming (ADS) Technology maximizes CPU<br />

processes to deliver smooth and reliable data transfers and the highest consistent<br />

performance. ATTO pays close attention to detail in board design and signal integrity to<br />

minimize transmission errors and data corruption. These differentiating capabilities make<br />

ATTO the premier choice for high-performance direct-attached SAS/SATA storage<br />

connectivity.<br />

Advanced Management Tools<br />

ATTO’s easy-to-use Configuration Tool features an intuitive GUI that simplifies the<br />

installation, management and monitoring of the host bus adapter. With advanced<br />

troubleshooting and performance tuning capabilities, ExpressSAS HBAs provide users with<br />

sophisticated diagnostics and the flexibility to control settings for specific applications.<br />

Technical Features<br />

• Port configurations include 16 external,<br />

16 internal, 8 external, 8 internal, and<br />

4 external/4 internal<br />

• 1200 MB/s per port/phy throughput in<br />

full-duplex mode<br />

• Features a high-performance x8 PCIe<br />

2.0 host interface<br />

• SAS 2.0, SAS, SATA and SATA II support<br />

• Supports up to 512 SAS/SATA devices<br />

• Driver support for Windows®, Linux,<br />

Mac® OS X, VMware® and more<br />

• Exclusive Advanced Data Streaming<br />

(ADS) Technology<br />

• Proven interoperability with support for<br />

SNIA HBA API<br />

• ATTO Configuration Tool for<br />

customized performance settings<br />

• Low power consumption<br />

• Target mode support<br />

• 3-year standard product warranty<br />

attotech.com 716.691.1999


6Gb/s SAS/SATA <strong>Host</strong> Bus <strong>Adapters</strong><br />

ExpressSAS H6F0, H60F, H680, H608, H644<br />

Tech Sheet<br />

Technical Specifications<br />

Applications<br />

ExpressSAS 6Gb/s SAS/SATA host bus adapters offer the fastest available connection to direct-attached SAS or SATA storage. The impressive speed of the ExpressSAS family of<br />

next-generation 6Gb/s HBAs delivers a future-proof solution for data-intensive IT and digital media applications such as tape backup, data warehousing, high-definition video,<br />

post-production, and digital film production.<br />

Dimensions<br />

Advanced Data Streaming (ADS)<br />

Latency-management technology that controls the<br />

acceleration of data transfers to move large<br />

amounts of data faster and more efficiently.<br />

Key Features<br />

▪ SAS 2.0, SAS, SATA and SATA II support<br />

▪<br />

▪<br />

▪<br />

▪<br />

▪<br />

▪<br />

▪<br />

▪<br />

▪<br />

Auto Negotiation between 6Gb/s, 3Gb/s and<br />

1.5Gbs devices<br />

Supports SSP, SMP, STP protocols<br />

SGPIO support<br />

PC BIOS bootability<br />

Global and dedicated hot spares<br />

SES, SNMP and S.M.A.R.T. support<br />

Initiator and target mode (OEM) support<br />

Flash ROM for easy field updates<br />

Wide-port end device support<br />

User Benefits<br />

▪ Highest available MB/s and IOPS performance<br />

▪<br />

▪<br />

▪<br />

Superior system performance with latest SAS/<br />

SATA technology<br />

Low power consumption<br />

Support for virtualized server environments<br />

Management Tools<br />

▪ Command Line Interface for advanced<br />

functionality<br />

▪ ATTO Config Tool (w/GUI) BIOS-based<br />

management and configuration utility<br />

Bus Specifications<br />

▪ x8 PCI Express 2.0 host interface<br />

▪ Supports PCI Express Base Spec 2.0<br />

▪ Supports PCI Express CEM Spec 2.0<br />

External Connectivity<br />

▪ Low profile (H60F, H680, H608, H644) and full<br />

height (H6F0) bracket<br />

▪ x4 MiniSAS Connectors<br />

▪ External LEDs for on-line and speed status for<br />

each port<br />

Operating System Support<br />

▪ Windows® Server 2003, 2008,<br />

▪ Windows XP, Vista, 7<br />

▪ Red Hat & SUSE Linux<br />

▪ Mac ®OS X (10.4.x - 10.6.x)<br />

▪ VMware® ESX Server 3.5<br />

▪ VMware® ESX Server vSphere 4.1<br />

Agency Approvals<br />

▪ FCC Part 15, Subpart B, Class A<br />

▪ EN55024: 1998A + A1: 2001 & A2: 2003<br />

▪ EN60825-1: 1994-2: 2004<br />

▪ EN55022: 2006, Class B<br />

Compliance<br />

▪ EN60950-1: 2001<br />

▪ RoHS Compliant<br />

H6F0<br />

▪ Length 6.600”, Height 4.376”<br />

H60F<br />

▪ Length 8.638”, Height 2.846”<br />

H680<br />

▪ Length 6.600”, Height 2.731”<br />

H608, H644<br />

▪ Length 5.600”, Height 2.731”<br />

Operating Temperature<br />

Hardware Environment<br />

▪ Temperature: 0-40°C (34°-104°F)<br />

▪ Humidity: 10 - 90% non-condensing<br />

Storage Environment<br />

▪ Temperature: -40°-70°C (-40°-157°F)<br />

▪ Humidity: 5 - 95% non-condensing<br />

Operating Voltage<br />

H6F0, H60F<br />

▪ 22W (typical)<br />

H680<br />

▪ 7.8W (typical)<br />

H608, H644<br />

▪ 8.3W (typical)<br />

Airflow<br />

▪ 100 lf/m (min) recommended<br />

Warranty<br />

▪ 3 Year<br />

TTO<br />

ATTO ExpressSAS<br />

H6F0<br />

ATTO ExpressSAS<br />

H60F<br />

ATTO ExpressSAS<br />

H680<br />

ATTO ExpressSAS<br />

H608<br />

ATTO ExpressSAS<br />

H644<br />

Ports 16 External 16 Internal 8 External 8 Internal 4 External/4 Internal<br />

Bus Characteristics x8 PCIe 2.0 x8 PCIe 2.0 x8 PCIe 2.0 x8 PCIe 2.0 x8 PCIe 2.0<br />

Form Factor Full Height Low Profile Low Profile Low Profile Low Profile<br />

Connectors<br />

4 Mini SAS (x4)<br />

SFF 8088 External<br />

4 Mini SAS (x4)<br />

SFF 8087 Internal<br />

2 Mini SAS (x4)<br />

SFF 8088 External<br />

2 Mini SAS (x4)<br />

SFF 8087 Internal<br />

1 Mini SAS (x4)<br />

SFF 8088 External<br />

1 Mini SAS (x4)<br />

SFF 8087 Internal<br />

Device Support 512 512 256 256 256<br />

Part Number ESAS-H6F0-000 ESAS-H60F-000 ESAS-H680-000 ESAS-H608-000 ESAS-H644-000<br />

attotech.com 716.691.1999<br />

2/11 Product features and specifications are subject to change without notice.


Tech Sheet<br />

3Gb/s SAS/SATA <strong>Host</strong> Bus <strong>Adapters</strong><br />

ExpressSAS H30F<br />

ExpressSAS H380<br />

ExpressSAS H308<br />

ATTO’s ExpressSAS 3Gb/s SAS/SATA <strong>Host</strong> Bus <strong>Adapters</strong><br />

provide high-performance connectivity for a wide range<br />

of Direct Attached Storage infrastructures.<br />

Industry Proven Technology<br />

ExpressSAS 3Gb/s host bus adapters leverage the performance and reliability<br />

enhancements of Serial Attached SCSI (SAS) technology to deliver high performance<br />

connectivity to SAS/SATA storage. ExpressSAS HBAs are engineered for the most stringent<br />

digital media workgroup and IT server environments, and are compatible with a wide array<br />

of 3rd party products, such as HDDs and SSDs, storage arrays and many other SAS and<br />

SATA infrastructure products.<br />

Flexible Connectivity Solutions<br />

ExpressSAS 3Gb/s SAS/SATA HBA’s provide flexible connectivity to SAS/SATA storage. With<br />

16 internal, 8 external or 8 internal port configurations, users benefit from cost-effective<br />

and efficient scalability. With support for SAS, SATA and SATA II connectivity, ExpressSAS<br />

3Gb/s host bus adapters are ideal for a variety of storage environments.<br />

Performance Engineered<br />

ExpressSAS 3Gb/s host bus adapters combine 3Gb/s SAS speeds and x8 PCI Express with<br />

powerful hardware and software elements to manage latency in real-time environments.<br />

Exclusive Advanced Data Streaming (ADS) Technology maximizes CPU processes to<br />

deliver smooth and reliable data transfers and the highest consistent performance. ATTO<br />

pays close attention to detail in board design and signal integrity to minimize transmission<br />

errors and data corruption. These differentiating capabilities make ATTO the premier<br />

choice for high-performance direct-attached SAS/SATA storage connectivity.<br />

Technical Features<br />

• Port configurations include 16 internal,<br />

8 external and 8 internal<br />

• 600 MB/s per port/phy throughput in<br />

full-duplex mode<br />

• Features a high-performance x8 PCIe<br />

host interface<br />

• Low-profile form factor<br />

• SAS, SATA and SATA II connectivity<br />

• Supports up to 256 SAS/SATA devices<br />

• Driver support for Windows®, Linux,<br />

Mac® OS X, VMware® and more<br />

• Exclusive Advanced Data Streaming<br />

(ADS) Technology<br />

• Proven interoperability with support for<br />

SNIA HBA API<br />

• ATTO Configuration Tool for<br />

customized performance settings<br />

• Low power consumption<br />

• 3-year standard product warranty<br />

Advanced Management Tools<br />

ATTO’s easy-to-use Configuration Tool features an intuitive GUI that simplifies the<br />

installation, management and monitoring of the host bus adapter. With advanced<br />

troubleshooting and performance tuning capabilities, ExpressSAS HBAs provide users with<br />

sophisticated diagnostics and the flexibility to control settings for specific applications.<br />

attotech.com 716.691.1999


3Gb/s SAS/SATA <strong>Host</strong> Bus <strong>Adapters</strong><br />

ExpressSAS H30F, H380, H308<br />

Tech Sheet<br />

Technical Specifications<br />

Applications<br />

ExpressSAS 3Gb/s SAS/SATA host adapters deliver high performance connectivity to direct attached SAS or SATA storage. The impressive performance of the ExpressSAS family<br />

of 3Gb/s HBAs is perfect for a wide array of data-intensive IT and digital media applications such as tape backup, data warehousing, high-definition video, post-production, and<br />

digital film production.<br />

Advanced Data Streaming (ADS)<br />

Latency-management technology that controls the<br />

acceleration of data transfers to move large<br />

amounts of data faster and more efficiently.<br />

Key Features<br />

▪ SAS, SATA and SATA II support<br />

▪<br />

▪<br />

▪<br />

▪<br />

▪<br />

▪<br />

▪<br />

Auto Negotiation between 3Gb/s and 1.5Gb/s<br />

devices<br />

Supports SSP, SMP, STP protocols<br />

PC BIOS bootability<br />

SGPIO support<br />

SES, SNMP and S.M.A.R.T. support<br />

Flash ROM for easy field updates<br />

Advanced management functions<br />

User Benefits<br />

▪ High performance (MB/s and IOPS)<br />

▪<br />

▪<br />

▪<br />

Superior system performance with SAS/SATA<br />

technology<br />

Low power consumption<br />

Support for virtualized server environments<br />

Management Tools<br />

▪ Command Line Interface for advanced<br />

functionality<br />

▪ ATTO Config Tool (w/GUI) BIOS-based<br />

management and configuration utility<br />

Bus Specifications<br />

▪ x8 PCI Express host interface<br />

▪ Supports PCI Express Base Spec 1.0a<br />

External Connectivity<br />

▪ Low profile bracket<br />

▪ x4 MiniSAS Connectors<br />

▪<br />

External LEDs for on-line and speed status for<br />

each port<br />

Operating System Support<br />

▪ Windows Server 2003, 2008, XP, Vista, 7<br />

▪ Red Hat & SUSE Linux<br />

▪ Mac OS X (10.4.x - 10.6.x)<br />

▪ VMware® ESX Server 3.5<br />

Agency Approvals<br />

▪ FCC Part 15, Class B<br />

▪ CISPR 22:2002<br />

▪ EN55022: 2002, Class B<br />

Compliance<br />

▪ RoHS<br />

Dimensions<br />

H30F<br />

▪ Length 6.600”, Height 2.900”<br />

H380, H308<br />

▪ Length 5.600”, Height 2.731”<br />

Operating Temperature<br />

Hardware Environment<br />

▪ Temperature: 0-60°C (32°-140°F) at 300 lf/m<br />

airflow<br />

▪ Temperature: 0-40°C (32°-104°F) at 150 lf/m<br />

airflow<br />

▪ Humidity: 5 - 95% non-condensing<br />

Storage Environment<br />

▪ Temperature: -40°-70°C (-40°-157°F)<br />

▪ Humidity: 5 - 95% non-condensing<br />

Operating Voltage<br />

H30F<br />

▪ 12V @ 1.45A max.<br />

▪ 3.3V @ .50A max<br />

▪ 19W (typical)<br />

H380<br />

▪ 12V @ .59A max.<br />

▪ 3.3V @ .87A max.<br />

▪ 10W (typical)<br />

H308<br />

▪ 12V @ 1.05A max.<br />

▪ 3.3V @ .45A max<br />

▪ 10W (typical)<br />

Airflow<br />

▪ 150 lf/m (min) recommended<br />

Warranty<br />

▪ 3 Year<br />

ATTO ExpressSAS H30F<br />

ATTO ExpressSAS H380<br />

ATTO ExpressSAS H308<br />

Ports<br />

16 Internal<br />

Ports<br />

8 External<br />

Ports<br />

8 Internal<br />

Bus Characteristics<br />

x8 PCIe<br />

Bus Characteristics<br />

x8 PCIe<br />

Bus Characteristics<br />

x8 PCIe<br />

Form Factor<br />

Low Profile<br />

Form Factor<br />

Low Profile<br />

Form Factor<br />

Low Profile<br />

Connectors<br />

4 Mini SAS (x4)<br />

SFF 8087 Internal<br />

Connectors<br />

2 Mini SAS (x4)<br />

SFF 8088 External<br />

Connectors<br />

2 Mini SAS (x4)<br />

SFF 8087 Internal<br />

Part Number<br />

ESAS-H30F-000<br />

Part Number<br />

ESAS-H380-000<br />

Part Number<br />

ESAS-H308-000<br />

attotech.com 716.691.1999<br />

2/11 Product features and specifications are subject to change without notice.


Data Sheet<br />

6Gb/s SAS/SATA RAID <strong>Adapters</strong><br />

ExpressSAS R60F<br />

ExpressSAS R680<br />

ExpressSAS R608<br />

ExpressSAS R644<br />

ATTO’s ExpressSAS 6Gb/s SAS/SATA RAID <strong>Adapters</strong> offer<br />

the fastest available connectivity to SAS or SATA storage<br />

with integrated RAID protection.<br />

Long-Standing RAID Experience<br />

Leveraging over 18 years of RAID technology development, ATTO’s family of ExpressSAS<br />

6Gb/s SAS/SATA RAID adapters feature the time-proven ATTO RAID Stack, DVRAID and<br />

CacheAssure, propietary technologies developed to provide the most robust RAIDbased<br />

connectivity solution in the industry.<br />

Flexible Connectivity Solutions<br />

With several port configuration options including 16 internal, 8 external, 8 internal, and 4<br />

external/4 internal, ExpressSAS 6Gb/s SAS/SATA RAID adapters are ideal for a wide variety<br />

of IT and digital media environments requiring high-performance and parity RAID<br />

protected data. ExpressSAS RAID adapters offer driver support for Windows®, Linux and<br />

Mac® OS X, providing a single connectivity solution for customers with heterogeneous<br />

operating system environments.<br />

Performance Engineered<br />

The ExpressSAS 6Gb/s SAS/SATA RAID adapter family allows users to instantly protect their<br />

critical data while enhancing performance. ATTO designs ExpressSAS RAID adapters to<br />

maintain full performance in degraded mode and to minimize downtime with 50% faster<br />

rebuilds, limiting exposure to a second drive failure. Exclusive latency management<br />

features like Advanced Data Streaming (ADS) Technology and DriveAssure minimize<br />

data transfer interruptions to ensure the highest level of consistent performance. These<br />

differentiating capabilities make ATTO the premier choice for high-performance hostbased<br />

RAID connectivity.<br />

Advanced Management Tools<br />

ATTO’s easy-to-use Configuration Tool features an intuitive GUI that simplifies RAID group<br />

configuration, management and monitoring. ATTO’s ExpressSAS RAID adapters offer the<br />

most advanced performance tuning capabilities and troubleshooting utilities, providing<br />

users with sophisticated diagnostics and the flexibility to control settings for specific<br />

applications.<br />

Technical Features<br />

• Port configurations include 16 internal,<br />

8 external, 8 internal, and 4 internal /<br />

4 external<br />

• 1200 MB/s per port/phy throughput in<br />

full-duplex mode<br />

• Features a high-performance x8 PCIe<br />

2.0 host interface<br />

• Low-profile form factor<br />

• SAS 2.0, SAS, SATA and SATA II<br />

connectivity<br />

• Supports up to 128 SAS/SATA devices<br />

• Exclusive Advanced Data Streaming<br />

(ADS) Technology, DriveAssure and<br />

CacheAssure<br />

• Data Recovery mode increases the<br />

probability of retrieving lost data from a<br />

failed drive<br />

• Disk and Tape support in one PCIe slot<br />

• Driver support for Windows®, Linux,<br />

and Mac® OS X<br />

• CacheAssure (option) for secure<br />

backup of data<br />

• RAID 0, 1, 4, 5, 6, 10, 40, 50, 60, JBOD<br />

and DVRAID<br />

attotech.com<br />

716.691.1999


6Gb/s SAS/SATA RAID <strong>Adapters</strong><br />

ExpressSAS R60F, R680, R608, R644<br />

Data Sheet<br />

Technical Specifications<br />

Applications<br />

ExpressSAS RAID adapters add high-performance RAID data protection to direct-attached SAS and SATA JBOD storage. They are an ideal connectivity solution for high-performance<br />

media and entertainment and general IT environments. ExpressSAS 6Gb/s SAS/SATA RAID adapters deliver affordable host-level RAID for high-bandwidth workflows such as digital<br />

content creation, streaming video, transactional databases, and email and Web servers.<br />

Advanced Data Streaming (ADS)<br />

Latency-management technology that controls the<br />

acceleration of data transfers to move large amounts of<br />

data faster and more efficiently.<br />

DriveAssure Technology<br />

Drive assessment and latency management technology<br />

that minimizes the likelihood of RAID groups becoming<br />

degraded or taken offline due to slow drives, ensuring<br />

uninterrupted access to data.<br />

CacheAssure Technology<br />

Flash-based protection module providing a<br />

maintenance-free solution that safeguards against the<br />

loss of cached data during a power or system failure.<br />

RAID Features and Functionality<br />

▪ SAS 2.0, SAS, SATA and SATA II support<br />

▪ RAID Levels 0, 1, 4, 5, 6, 10, 40, 50, 60, JBOD,<br />

DVRAID<br />

▪ ATTO RAID stack<br />

▪ Command coalescing<br />

▪ Staggered drive spin-up<br />

▪ RAID level migration<br />

▪ Hot swap with auto rebuild<br />

▪ Online performance metrics and event logs<br />

▪ Native command queuing<br />

▪ 512MB ECC protected cache memory<br />

▪ SES, SNMP and S.M.A.R.T. Support<br />

▪ Pass-through support for tape and tape devices<br />

▪ Configurable stripe size<br />

▪ Online capacity expansion<br />

▪ Global and dedicated hot spares<br />

▪ Automatic and tunable online rebuilds<br />

▪ N-way mirroring<br />

User Benefits<br />

▪ High performance host-based RAID for directattached<br />

storage<br />

▪ Four port configurations for flexible connectivity<br />

▪ Full performance in degraded or rebuild mode<br />

▪ Flash-based cache protection protects against lost<br />

data during power or system failure<br />

▪ More options for retrieving data from a failed drive<br />

with Data Recovery mode<br />

▪ 50% faster rebuilds<br />

▪ Efficient scalability with host-level RAID<br />

▪ Maintain high priority workflows with tunable<br />

rebuilds<br />

▪ RAID group partitioning for better management<br />

Management Tools<br />

▪ User-friendly GUI for quick and easy RAID setup<br />

▪ Command Line Interface for advanced functionality<br />

▪ ATTO Config Tool: BIOS-based RAID management<br />

and configuration utility<br />

Bus Specifications<br />

▪ x8 PCI Express 2.0 host interface<br />

External Connectivity<br />

▪ x4 Mini SAS connectors<br />

▪ Low profile form factor; full-height bracket included<br />

Operating System Support<br />

▪ Windows® Server 2003, 2008,<br />

▪ Windows XP, Vista, 7<br />

▪ SUSE Linux<br />

▪ Red Hat Linux<br />

▪ Mac ®OS X (10.4.x - 10.6.x)<br />

Agency Approvals<br />

▪ FCC Part 15, Subpart B, Class B<br />

▪ EN55024: 1998 + A1: 2001 + A2: 2003<br />

▪ EN55022: 2006, Class B<br />

Compliance<br />

▪ EN60950-1: 2001<br />

▪ RoHS-6<br />

Dimensions<br />

R60F<br />

▪ Length 8.638”, Height 2.846”<br />

R608/R680/R644<br />

▪ Length 6.600”, Height 2.713”<br />

Operating Temperature<br />

Hardware Environment<br />

▪ Temperature: 0-40° C<br />

▪ Humidity: 10 - 90% non-condensing<br />

Storage Environment<br />

▪ Temperature: -40°-70°C (-40°-157°F)<br />

▪ Humidity: 5 - 95% non-condensing<br />

Operating Voltage<br />

R60F<br />

▪ 18W (typical)<br />

R680/R608/R644<br />

▪ 9.6W (typical)<br />

Airflow<br />

▪ 150 lf/m (min) recommended<br />

Warranty<br />

▪ 3 Year<br />

ATTO ExpressSAS R60F ATTO ExpressSAS R680 ATTO ExpressSAS R608 ATTO ExpressSAS R644<br />

Ports 16 Internal 8 External 8 Internal 4 External/4 Internal<br />

Bus Characteristics x8 PCIe 2.0 x8 PCIe 2.0 x8 PCIe 2.0 x8 PCIe 2.0<br />

Form Factor Low Profile Low Profile Low Profile Low Profile<br />

Connectors<br />

4 Mini SAS (x4)<br />

SFF 8087 Internal<br />

2 Mini SAS (x4)<br />

SFF 8088 External<br />

2 Mini SAS (x4)<br />

SFF 8087 Internal<br />

1 Mini SAS (x4)<br />

SFF 8088 External<br />

1 Mini SAS (x4)<br />

SFF 8087 Internal<br />

Part Number<br />

With CacheAssure option<br />

ESAS-R60F-000<br />

ESAS-R60F-C00<br />

ESAS-R680-000<br />

ESAS-R680-C00<br />

ESAS-R608-000<br />

ESAS-R608-C00<br />

ESAS-R644-000<br />

ESAS-R644-C00<br />

attotech.com<br />

716.691.1999<br />

2/11 Product features and specifications are subject to change without notice.


Tech Sheet<br />

3Gb/s SAS/SATA RAID <strong>Adapters</strong><br />

ExpressSAS R30F<br />

ExpressSAS R380<br />

ExpressSAS R348<br />

ATTO’s ExpressSAS 3Gb/s SAS/SATA RAID <strong>Adapters</strong><br />

add high-performance parity RAID data protection<br />

to direct-attached SAS and SATA JBOD storage.<br />

Long-Standing RAID Experience<br />

Leveraging over 18 years of RAID technology development, ATTO’s family of ExpressSAS<br />

3Gb/s SAS/SATA RAID adapters feature the time-proven ATTO RAID Stack, DVRAID and<br />

DriveAssure, propietary technologies developed to provide the most robust RAID-based<br />

connectivity solution in the industry.<br />

Flexible Connectivity Solutions<br />

With several port configuration options including 16 internal, 8 external and a userselectable<br />

4 internal/4 external or 8 internal, ExpressSAS 3Gb/s SAS/SATA RAID adapters<br />

are ideal for a wide variety of IT and digital media environments requiring highperformance<br />

and parity RAID protected data. ExpressSAS RAID adapters offer driver<br />

support for Windows®, Linux and Mac® OS X, providing a single connectivity solution for<br />

customers with heterogeneous operating system environments.<br />

Performance Engineered<br />

The ExpressSAS 3Gb/s SAS/SATA RAID adapter family allows users to instantly protect their<br />

critical data without compromising performance. ATTO designs ExpressSAS RAID adapters<br />

to maintain full performance in degraded mode and to minimize downtime with 50%<br />

faster rebuilds, limiting exposure to a second drive failure. Exclusive latency management<br />

features like Advanced Data Streaming (ADS) Technology and DriveAssure minimize<br />

data transfer interruptions to ensure the highest level of consistent performance. These<br />

differentiating capabilities make ATTO the premier choice for high-performance hostbased<br />

RAID connectivity.<br />

Technical Features<br />

• Port configurations include 16 internal,<br />

8 external and user-selectable<br />

4 internal / 4 external or 8 internal<br />

• 600 MB/s per port/phy throughput in<br />

full-duplex mode<br />

• Features an x8 PCIe host interface<br />

• Low-profile form factor<br />

• SAS, SATA and SATA II connectivity<br />

• Supports up to 128 SAS/SATA devices<br />

• Exclusive Advanced Data Streaming<br />

(ADS) Technology and DriveAssure<br />

• Data Recovery mode increases the<br />

probability of retrieving lost data from<br />

a failed drive<br />

• Disk and Tape support in one PCIe slot<br />

• Driver support for Windows®, Linux,<br />

and Mac® OS X<br />

• RAID 0, 1, 4, 5, 6, 10, 40, 50, 60, JBOD<br />

and DVRAID®<br />

• 3-year standard product warranty<br />

Advanced Management Tools<br />

ATTO’s easy-to-use Configuration Tool features an intuitive GUI that simplifies RAID group<br />

configuration, management and monitoring. ATTO’s ExpressSAS RAID adapters offer the<br />

most advanced performance tuning capabilities and troubleshooting utilities, providing<br />

users with sophisticated diagnostics and the flexibility to control settings for specific<br />

applications.<br />

attotech.com<br />

716.691.1999


3Gb/s SAS/SATA RAID <strong>Adapters</strong><br />

ExpressSAS R30F, R380, R348<br />

Tech Sheet<br />

Technical Specifications<br />

Applications<br />

ExpressSAS RAID adapters add high-performance RAID data protection to direct-attached SAS and SATA JBOD storage. They are an ideal connectivity solution for high-performance<br />

media and entertainment and general IT environments. ExpressSAS 3Gb/s SAS/SATA RAID adapters deliver affordable host-level RAID for high-bandwidth workflows such as digital<br />

content creation, streaming video, transactional databases, and email and Web servers.<br />

Advanced Data Streaming (ADS)<br />

Latency-management technology that controls the<br />

acceleration of data transfers to move large amounts of<br />

data faster and more efficiently.<br />

DriveAssure Technology<br />

Drive assessment and latency management technology<br />

that minimizes the likelihood of RAID groups becoming<br />

degraded or taken offline due to slow drives, ensuring<br />

uninterrupted access to data.<br />

RAID Features and Functionality<br />

▪ SAS, SATA and SATA II support<br />

▪<br />

▪<br />

▪<br />

▪<br />

▪<br />

▪<br />

▪<br />

▪<br />

▪<br />

▪<br />

▪<br />

▪<br />

▪<br />

▪<br />

▪<br />

▪<br />

▪<br />

RAID Levels 0, 1, 4, 5, 6, 10, 40, 50, 60, JBOD,<br />

DVRAID<br />

ATTO RAID stack<br />

Command coalescing<br />

Support for staggered drive spin-up<br />

RAID level migration<br />

Hot swap with auto rebuild<br />

Online performance metrics and event logs<br />

Native command queuing<br />

256/512MB ECC protected cache memory<br />

SES, SNMP and S.M.A.R.T. Support<br />

DVRAID for high-bandwidth video environments<br />

Pass-through support for tape and tape devices<br />

Configurable stripe size<br />

Online capacity expansion<br />

Global and dedicated hot spares<br />

Automatic and tunable online rebuilds<br />

N-way mirroring<br />

User Benefits<br />

▪ High performance host-based RAID for directattached<br />

storage<br />

▪ Three port configurations for flexible connectivity<br />

▪ Full performance in degraded or rebuild mode<br />

▪ More options for retrieving data from a failed drive<br />

with Data Recovery mode<br />

▪ Affordable and scalable storage expansion<br />

alternative to RAID arrays<br />

▪ 50% faster rebuilds<br />

▪ Maintain high priority workflows with tunable<br />

rebuilds<br />

▪ RAID group partitioning for better management<br />

Management Tools<br />

▪ User-friendly GUI for quick and easy RAID setup<br />

▪ Command Line Interface for advance functionality<br />

▪<br />

ATTO Config Tool: BIOS-based RAID management<br />

and configuration utility<br />

Bus Specifications<br />

▪ x8 PCI Express host interface<br />

External Connectivity<br />

▪ x4 Mini SAS connectors<br />

▪ Low profile form factor; full-height bracket included<br />

▪<br />

External LEDs for on-line & speed status for each<br />

port<br />

Operating System Support<br />

▪ Windows® Server 2003, 2008,<br />

▪ Windows XP, Vista, 7<br />

▪ SUSE Linux<br />

▪ Red Hat Linux<br />

▪ Mac® OS X (10.4.x - 10.6.x)<br />

Agency Approvals<br />

▪ FCC Part 15, Subpart B, Class B<br />

▪ CE Mark: CISPR 22:2002<br />

▪ EN55022: 2006, Class B<br />

Compliance<br />

▪ RoHS<br />

Dimensions<br />

R30F<br />

▪ Length 8.640”, Height 2.900”<br />

R380/R348<br />

▪ Length 6.600”, Height 2.731”<br />

Operating Temperature<br />

Hardware Environment<br />

▪ Temperature: 0-40°C (32°-104° F) - R380/R348<br />

▪ Temperature: 0-60°C (32°-104° F) - R30F<br />

▪ Humidity: 5 - 95% non-condensing<br />

Storage Environment<br />

▪ Temperature: -40°-70°C (-40°-157°F)<br />

▪ Humidity: 5 - 95% non-condensing<br />

Operating Voltage<br />

R30F<br />

▪ 17W (typical)<br />

R380/R348<br />

▪ 13W (typical)<br />

Airflow<br />

▪ 150 lf/m (min) recommended<br />

Warranty<br />

▪ 3 Year<br />

ATTO ExpressSAS R30F<br />

ATTO ExpressSAS R380<br />

ATTO ExpressSAS R348<br />

Ports<br />

16 Internal<br />

Ports<br />

8 External<br />

Ports<br />

User Selectable<br />

4 Ext/4 Int or 8 Int<br />

Bus Characteristics<br />

x8 PCIe<br />

Bus Characteristics<br />

x8 PCIe<br />

Bus Characteristics<br />

x8 PCIe<br />

Form Factor<br />

Low Profile<br />

Form Factor<br />

Low Profile<br />

Form Factor<br />

Low Profile<br />

Connectors<br />

4 Mini SAS (x4)<br />

SFF 8087 Internal<br />

Connectors<br />

2 Mini SAS (x4)<br />

SFF 8088 External<br />

Connectors<br />

1 Mini SAS (x4)<br />

SFF 8088 External,<br />

2 Mini SAS (x4)<br />

SFF 8087 Internal<br />

Part Number<br />

ESAS-R30F-000<br />

Part Number<br />

ESAS-R380-000<br />

Part Number<br />

ESAS-R348-000<br />

attotech.com<br />

716.691.1999<br />

2/11 Product features and specifications are subject to change without notice.


Tech Sheet<br />

Ultra320 SCSI <strong>Host</strong> Bus <strong>Adapters</strong><br />

ExpressPCI UL5D LP<br />

ExpressPCI UL5D<br />

ExpressPCI UL4D<br />

The ATTO ExpressPCI SCSI host bus adapter family complements<br />

high-performance Direct Attached Storage (DAS) configurations in<br />

multiple environments by providing a flexible and reliable storage<br />

solution for servers and workstations.<br />

Industry Proven<br />

ATTO ExpressPCI Ultra320 SCSI host bus adapters offer high-performance connectivity to<br />

tape and external storage. The UL5D LP, UL5D and UL4D SCSI HBAs help users meet the<br />

demands of a wide variety of high-bandwidth applications in Mac®, Windows® or Linux<br />

environments.<br />

Performance Engineered<br />

ExpressPCI SCSI host bus adapters feature a PCI Express or PCI-X interconnect and boast<br />

speeds of up to 640MB/s. With exclusive Advanced Data Streaming (ADS TM ) technology,<br />

the UL5D LP, UL5D and UL4D effectively manage latency for fast and efficient data<br />

transfers. ADS Technology ensures best-in-industry data transfers by controlling the<br />

acceleration of data to maintain the highest consistent performance. The combination of<br />

Ultra320 SCSI and PCI Express makes ExpressPCI HBAs ideal for workstations running<br />

bandwidth-intensive applications such as video editing, messaging and databases.<br />

Easy to Use<br />

ExpressPCI SCSI host bus adapters come with ATTO’s factory-preset configurations for outof-the-box<br />

plug and play operation. The ATTO Configuration Tool, featuring an easy-to-use<br />

GUI, simplifies the installation, management and monitoring of the HBA. The Configuration<br />

Tool enables the best possible performance by allowing users to modify the adapter’s<br />

default settings.<br />

Technical Features<br />

• Dual <strong>Channel</strong> (2 internal, 2 external)<br />

Ultra320 SCSI<br />

• Up to 320MB/s per channel throughput<br />

in full-duplex mode<br />

• x4 PCI Express or 64-bit,133MHz PCI-X<br />

connections<br />

• Driver support for Mac®, Windows®,<br />

Linux, and more<br />

• Exclusive Advanced Data Streaming<br />

(ADS) Technology<br />

• ATTO Configuration Tool for customized<br />

performance settings<br />

• Low voltage differential<br />

• Supports up to 30 SCSI bus IDs<br />

• Up to 12 meter cable lengths<br />

• 3-year standard product warranty<br />

• Low power consumption<br />

attotech.com 1.716.691.1999


Ultra320 SCSI <strong>Host</strong> Bus <strong>Adapters</strong><br />

ExpressPCI UL5D LP, UL5D, UL4D<br />

Tech Sheet<br />

Technical Specifications<br />

Applications<br />

ATTO ExpressPCI SCSI host bus adapters are specifically engineered for reliable storage connectivity and high-performance for data-intensive environments such as HD video<br />

editing, transactional database applications and large server farms. ExpressPCI SCSI HBAs are a field tested and time proven connectivity solution for direct attached storage<br />

environments.<br />

Advanced Data Streaming (ADS)<br />

Latency-management technology that controls the<br />

acceleration of data transfers to move large<br />

amounts of data faster and more efficiently.<br />

Key Features<br />

▪ Low voltage differential (LVD) signaling<br />

▪ Tagged command queuing support<br />

▪<br />

▪<br />

▪<br />

▪<br />

▪<br />

▪<br />

▪<br />

▪<br />

▪<br />

▪<br />

Backwards compatible with Ultra160, Ultra2<br />

and Ultra/WIDE<br />

Dynamic bus rescan<br />

Double transition clocking<br />

Domain validation and packetization<br />

Quick Arbitration Select (QAS)<br />

Bootable from attached disks<br />

On-board termination<br />

Flash ROM for easy field upgrades<br />

Cyclical Redundancy Checking (CRC)<br />

Optimized SCSI-3 algorithms<br />

Bus Specifications<br />

UL5D LP, UL5D<br />

▪ x4 PCI Express<br />

▪ Supports PCI Express Base and CEM Spec 1.0a<br />

▪ PCI Express to PCI/PCI-X Bridge spec 1.0<br />

UL4D<br />

▪ 64-bit/133MHz PCI-X<br />

▪ PCI-X 1.0a compliant<br />

▪ PCI 2.2 and PCI 99 compliant<br />

Management Tools<br />

▪ ATTO Config Tool (w/GUI) BIOS-based<br />

management and configuration utility<br />

Operating System Support<br />

▪ Windows® Server 2003, 2008<br />

▪ Windows XP, Vista, 7<br />

▪ Mac OS® X (10.4.x - 10.6.x)<br />

▪ SUSE Linux<br />

▪ Red Hat Linux<br />

▪ Novell Netware® v6.5<br />

Agency Approvals<br />

▪ FCC Part 15, Subpart B, Class A<br />

▪ CE Mark: CISPR 22/EN 55022, Class A<br />

Compliance<br />

▪ RoHS<br />

Dimensions<br />

UL5D LP<br />

▪ Length 6.6”, Height 2.713”<br />

UL5D<br />

▪ Length 7.5”, Height 4.376”<br />

UL4D<br />

▪ Length 6.521”, Height 4.450”<br />

Operating Temperature<br />

Hardware Environment<br />

▪ Temperature: 0-40° C<br />

▪ Humidity: 10 - 90% non-condensing<br />

Operating Voltage<br />

UL5D LP<br />

▪ 0.7 Amps @ +3.3 VDC<br />

▪ 0.6 Amps @ +12 VDC<br />

UL5D<br />

▪ 1.61 typical/2.03 max Amps @ +3.3 VDC<br />

▪ 0.6 5 typical/1.46 Amps @ +12 VDC<br />

UL4D<br />

▪ 0.75 typical/2.0 max Amps @ +5.0 VDC<br />

▪ 0.0 5 Amps @ +12 VDC<br />

Reliability (MTBF)<br />

UL5D LP<br />

▪ 675,000 hours<br />

UL5D<br />

▪ 675,000 hours<br />

UL4D<br />

▪ 150,000 hours<br />

Airflow<br />

▪ 100 lf/m (min) recommended<br />

Warranty<br />

▪ 3 Year<br />

ATTO ExpressPCI UL5D LP<br />

ATTO ExpressPCI UL5D<br />

ATTO ExpressPCI UL4D<br />

Power<br />

0.7 Amps @ + 3.3 VDC<br />

0.6 Amps @ + 12.0 VDC<br />

Power<br />

1.61 Amps@ + 3.3 VDC<br />

0.65 Amps @ + 12.0 VDC<br />

Power<br />

0.75 Amps @+5.0 VDC<br />

0.05 Amps @+12.0 VDC<br />

Dimensions Length = 6.6”<br />

Height = 2.713”<br />

Dimensions Length = 7.5”<br />

Height = 4.376”<br />

Dimensions Length = 6.521”<br />

Height = 4.450”<br />

Reliability<br />

MTBF = 675,000 Hours<br />

MTTR < 15 Minutes<br />

Reliability<br />

MTBF = 675,000 Hours<br />

MTTR < 15 Minutes<br />

Reliability<br />

MTBF = 150,000 Hours<br />

MTTR < 15 Minutes<br />

Part Number<br />

EPCI-UL5D-L00<br />

Part Number<br />

EPCI-UL5D-0R0<br />

Part Number<br />

EPCI-UL4D-0R0<br />

attotech.com 1.716.691.1999<br />

2/11 Product features and specifications are subject to change without notice.