Chapter 5.<br />

Characterizati<strong>on</strong> <str<strong>on</strong>g>of</str<strong>on</strong>g> Scaffolds for C<strong>on</strong>nective Tissue Engineering<br />

using <str<strong>on</strong>g>the</str<strong>on</strong>g> Mark-Houwink Relati<strong>on</strong>ship (MHR) with K = 2.2610 -5 dl/g and a = 0.796, <str<strong>on</strong>g>the</str<strong>on</strong>g> molecular weight<br />

we obtain: M vis = 2 637 540 g/mol.<br />

1.1.2 Discussi<strong>on</strong> <strong>on</strong> <str<strong>on</strong>g>the</str<strong>on</strong>g> Molecular Mass<br />

Experimental results have been compared with values given in data sheets with <str<strong>on</strong>g>the</str<strong>on</strong>g> different<br />

polylactides. All <str<strong>on</strong>g>the</str<strong>on</strong>g> values, reported <strong>on</strong> Table 5.4, are in <str<strong>on</strong>g>the</str<strong>on</strong>g> range <str<strong>on</strong>g>of</str<strong>on</strong>g> <str<strong>on</strong>g>the</str<strong>on</strong>g> specificati<strong>on</strong>s. Moreover, <str<strong>on</strong>g>the</str<strong>on</strong>g><br />

separati<strong>on</strong> between <str<strong>on</strong>g>the</str<strong>on</strong>g> two main medical applicati<strong>on</strong>s <str<strong>on</strong>g>of</str<strong>on</strong>g> <str<strong>on</strong>g>the</str<strong>on</strong>g> polylactides seems to be governed by <str<strong>on</strong>g>the</str<strong>on</strong>g><br />

intrinsic viscosity range <str<strong>on</strong>g>of</str<strong>on</strong>g> <str<strong>on</strong>g>the</str<strong>on</strong>g> polymers. Below a certain molecular mass (i.e. <str<strong>on</strong>g>the</str<strong>on</strong>g> critical mass), oligomers<br />

are used as c<strong>on</strong>trolled release and above this critical mass polymers can be used as medical device. As<br />

shown <strong>on</strong> Table 5.4, differences between polylactides <str<strong>on</strong>g>of</str<strong>on</strong>g> <str<strong>on</strong>g>the</str<strong>on</strong>g> same inherent viscosities range are not<br />

significant; <str<strong>on</strong>g>the</str<strong>on</strong>g>y can be chosen whatever <str<strong>on</strong>g>the</str<strong>on</strong>g>ir origin (Lactel, Purac, Boehringer).<br />

Table 5.4: Comparis<strong>on</strong> between molecular weight <str<strong>on</strong>g>of</str<strong>on</strong>g> various polylactides.<br />

Polylactides<br />

Data Sheet* Experiments M w Deduced<br />

inh (dL/g) inh (dL/g) from MHR<br />

Applicati<strong>on</strong>s<br />

P L,D LA (PABR L 68) 2.33 2.24 163 971 Packaging<br />

P L,DL LA (Resomer ® LR 704) 2.0 − 2.8 2.68 201 169 Medical device<br />

PLGA 85:15 (Resomer ® RG 858S) 1.3 − 1.7 1.62 57 529 C<strong>on</strong>trolled release<br />

PLGA 85:15 (DL-PLG) 0.55 − 0.75 0.72 18 943 C<strong>on</strong>trolled release<br />

PLGA 50:50 (PLG 8523) 2.27 2.21 88 033 Medical device<br />

PLGA 85:15 (PLG 8531) 3.11 2.96 131 366 Medical device<br />

PLGA 85:15 (LG 857 S) 5.0 − 7.0 6.63 396 495 Medical device<br />

PLGA 50:50 (Resomer ® RG 504) 0.45 − 0.60 0.59 14 756 C<strong>on</strong>trolled release<br />

PLGA 50:50 (PDLG 5010) 1.03 0.97 28 494 Medical device<br />

1.1.3 Characterizati<strong>on</strong> <str<strong>on</strong>g>of</str<strong>on</strong>g> Polylactide Powders by DSC<br />

<strong>The</strong> <str<strong>on</strong>g>the</str<strong>on</strong>g>rmograms <str<strong>on</strong>g>of</str<strong>on</strong>g> <str<strong>on</strong>g>the</str<strong>on</strong>g> different PLAs and PLGAs are presented in <str<strong>on</strong>g>the</str<strong>on</strong>g> Figure 5.2, Figure 5.3 and<br />

Figure 5.4. <strong>The</strong> <str<strong>on</strong>g>the</str<strong>on</strong>g>rmograms are representative <str<strong>on</strong>g>of</str<strong>on</strong>g> <str<strong>on</strong>g>the</str<strong>on</strong>g> sec<strong>on</strong>d scan run.<br />

Figure 5.2: <strong>The</strong>rmograms <str<strong>on</strong>g>of</str<strong>on</strong>g> various PLAs.<br />