TYPICAL <strong>SmartJoist</strong> FLOOR CONSTRUCTION DETAILS (Cont’d)<br />

Backer for cladding<br />

attachment.<br />

F6<br />

Use double<br />

joists under<br />

wall where<br />

vertical load<br />

exceeds<br />

29 KN/m<br />

<br />

WARNING - CORRECT BLOCKING<br />

FOR <strong>SmartJoist</strong>s<br />

GREEN TIMBER SHALL NOT BE USED<br />

UNDER ANY CIRCUMSTANCE.<br />

All blocking shall be carried out as per details F1-F3, with<br />

blocking to extend to both flanges and skew nailed with<br />

3.15 Ф x 65 nails, one each side of top and bottom flange.<br />

<strong>SmartJoist</strong> shall be designed<br />

to support load bearing wall<br />

above when not stacked over<br />

wall below.<br />

INTERIOR LOAD BEARING AND BRACING WALLS<br />

Load bearing wall<br />

above must stack<br />

over wall below<br />

2 mm<br />

<strong>SmartJoist</strong><br />

blocking<br />

Panel<br />

F7<br />

F8<br />

NOTE: Detail F7 with blocking panel is required for bracing walls.<br />

90 X 45 F5<br />

Cripple skew<br />

nailed to both<br />

flanges with<br />

3.15 x 65 nails.<br />

NON LOAD-BEARING CANTILEVER DETAILS (BALCONIES)<br />

Example cantilever spans and minimum back spans for this detail are shown in the table on the next page<br />

<strong>SmartJoist</strong> blocking<br />

Non Load bearing wall to a<br />

maximum height of 2400 mm<br />

200 x 50 mm Min. Nail to backer block & joist with 2 rows of 3.15 dia x 75 mm<br />

at 150 mm centres and clinch<br />

A<br />

70 mm<br />

MIN.<br />

Bearing.<br />

F9<br />

Min F8 - Durable or<br />

treated timber<br />

(UNIFORM LOADS ONLY).<br />

1200 mm MAX. 1200 mm MIN.<br />

L<br />

1.5 x L<br />

Non Load bearing wall<br />

to a maximum height<br />

of 2400 mm<br />

A<br />

Backer block - Nail with 2 rows of<br />

3.75 dia x 65 mm nails at 150 centres<br />

and clinch<br />

Section A-A<br />

UNIFORM LOADS ONLY<br />

<strong>SmartJoist</strong> blocking<br />

NOTE: <strong>SmartJoist</strong>s<br />

MUST BE PROTECTED<br />

FROM THE WEATHER<br />

<strong>SmartJoist</strong>s may be cantilevered up to 1/3<br />

of their back span.<br />

L/3 MAX.<br />

Example 1200 mm<br />

L<br />

Example: 3600 mm<br />

FOR CANTILEVERS SUPPORTING LOAD BEARING WALLS, SEE DETAILS C1 or C2.<br />

<strong>SmartJoist</strong> <strong>Design</strong> <strong>Guide</strong> 15