PRODUCT LIST<br />

Vacon Plc<br />

VACON NX_ Runsorintie 7<br />

65380 VAASA<br />

FINLAND<br />

Tel.: +358 (0)201 212 000<br />

Fax: +358 (0)201 212 205<br />

http://www.vacon.com<br />

VACON NX PRODUCT LIST <strong>2007</strong> BC00118 VER C<br />

Updated 8.2.<strong>2007</strong><br />

This productlist includes products which are not released to production or sales


Vacon Plc<br />

VACON PLC<br />

AC drive 8.2.<strong>2007</strong><br />

TABLE OF CONTENTS<br />

NX Air cooled products:<br />

PAGE<br />

NXL 208-240 V and 380-500 V:<br />

Vacon NXL 380-500 V, IP20 (cabinet assembly), EMC level N, air-cooled AC drive 1<br />

Vacon NXL 208-240 V, IP20 (cabinet assembly), EMC level N, air-cooled AC drive 1<br />

Vacon NXL 380-500 V, IP21, EMC level H/T, air-cooled AC drive 2<br />

Vacon NXL 380-500 V, IP54, EMC level H/T, air-cooled AC drive 2<br />

NXS 208-240 V:<br />

Vacon NXS 208-240 V, IP21, EMC level H/T, air-cooled AC drive 3<br />

Vacon NXS 208-240 V, IP54, EMC level H/T, air-cooled AC drive 4<br />

NXS 380-500 V:<br />

Vacon NXS 380-500 V, IP21, EMC level H/T, air-cooled AC drive 5<br />

Vacon NXS 380-500 V, IP54, EMC level H/T, air-cooled AC drive 6<br />

NXS 525-690 V:<br />

Vacon NXS 525-690 V, IP21, EMC level L/T, air-cooled AC drive 7<br />

Vacon NXS 525-690 V, IP54, EMC level L/T, air-cooled AC drive 8<br />

NXS Stand Alone:<br />

Vacon NXS 380-500 V, IP21, EMC level L/T, air-cooled standalone AC drive 9<br />

Vacon NX_ OPTIONS Integrated load switch for standalone 9<br />

Vacon NXS 380-500 V, IP54, EMC level L/T, air-cooled standalone AC drive 10<br />

Vacon NX_ OPTIONS Integrated load switch for standalone 10<br />

Vacon NXS 525-690 V, IP21, EMC level L/T, air-cooled standalone AC drive 11<br />

Vacon NX_ OPTIONS Integrated load switch for standalone 11<br />

Vacon NXS 525-690 V, IP54, EMC level L/T, air-cooled standalone AC drive 12<br />

Vacon NX_ OPTIONS Integrated load switch for standalone 12<br />

NXP 208-240 V:<br />

Vacon NXP 208-240 V, IP21, EMC level H/T, air-cooled AC drive 13<br />

Vacon NXP 208-240 V, IP54, EMC level H/T, air-cooled AC drive 14<br />

NXP 380-500 V:<br />

Vacon NXP 380-500 V, IP21, EMC level H/T, air-cooled AC drive 15<br />

Vacon NXP 380-500 V, IP54, EMC level H/T, air-cooled AC drive 16<br />

Vacon NXP 380-500 V, IP00, EMC level N/T, air-cooled AC drive module, 6-pulse supply 17<br />

Vacon NXP 380-500 V, IP00, EMC level N/T, air-cooled AC drive module, 12-pulse supply 18<br />

NXP 525-690 V:<br />

Vacon NXP 525-690 V, IP21, EMC level L/T, air-cooled AC drive 19<br />

Vacon NXP 525-690 V, IP54, EMC level L/T, air-cooled AC drive 20<br />

Vacon NXP 525-690 V, IP00, EMC level N/T, air-cooled AC drive module, 6-pulse supply 21<br />

Vacon NXP 525-690 V, IP00, EMC level N/T, air-cooled AC drive module, 12-pulse supply 22<br />

NXP Stand Alone:<br />

Vacon NXP 380-500 V, IP21, EMC level L/T, air-cooled standalone AC drive 23<br />

Vacon NX_ OPTIONS Integrated load switch for standalone 23<br />

Vacon NXP 380-500 V, IP54, EMC level L/T, air-cooled standalone AC drive 24<br />

Vacon NX_ OPTIONS Integrated load switch for standalone 24<br />

Vacon NXP 525-690 V, IP21, EMC level L/T, air-cooled standalone AC drive 25<br />

Vacon NX_ OPTIONS Integrated load switch for standalone 25<br />

Vacon NXP 525-690 V, IP54, EMC level L/T, air-cooled standalone AC drive 26<br />

Vacon NX_ OPTIONS Integrated load switch for standalone 26<br />

CONDITIONS<br />

PRICE = FCA VAASA, FINLAND (INCOTERMS 2000)<br />

PRICES ARE VALID FROM 1.3.<strong>2007</strong> UNTIL 31.12.<strong>2007</strong>; PRICES DO NOT INCLUDE ANY TAXES OR SIMILAR CHARGES<br />

SUBJECT TO CHANGE WITHOUT NOTICE<br />

Vacon Plc Runsorintie 7 65380 VAASA FINLAND tel.:+358-201-2121 fax: +358 (0)201 212 205 http://www.vacon.com


Vacon Plc<br />

VACON PLC<br />

AC drive 8.2.<strong>2007</strong><br />

TABLE OF CONTENTS<br />

PAGE<br />

NX_ OPTIONS:<br />

Vacon NX_ OPTIONS Internal rake choppers 27<br />

Vacon NX_ OPTIONS DC-connection (FR8-FR11) 28<br />

Vacon NX_ OPTIONS Internal brake resistors 28<br />

Vacon NX_ OPTIONS External brake resistors 29<br />

Vacon NX_ OPTIONS Overtemperature sensors 29<br />

Vacon NX_OPTIONS External du/dt filters 380-690 V 30<br />

Vacon NX_OPTIONS External sine wave filters 380-500 V and 525-690 V 30<br />

Vacon NX_ OPTIONS External filters for NXL 31<br />

Vacon NX_ OPTIONS External RFI filters 31<br />

Vacon NX_OPTIONS External RFI filters for NX 31<br />

Vacon NX_OPTIONS Integrated RFI filter options 31<br />

Vacon NX_ OPTIONS Enclosure kits 32<br />

Vacon NX_ OPTIONS Through hole mounting 32<br />

Vacon NX_OPTIONS Through hole mounting kits IP21 32<br />

Vacon NX_OPTIONS Through hole mounting kits IP54 32<br />

Vacon NX_ OPTIONS FR9 floor assembly option 32<br />

Vacon NX_ OPTIONS Display panels, Door installation sets, RS232 cables, Fiber optic cables, Ferrite rings 33<br />

Vacon NX_ OPTIONS Control unit enclosures for NXP 33<br />

Vacon NX_ OPTIONS I/O cards 34<br />

Vacon NX_ OPTIONS I/O cards reduction price 34<br />

Vacon NX_ OPTIONS I/O cards varnished 34<br />

Vacon NX_OPTIONS Software tools 35<br />

Vacon NX_OPTIONS Application Softwares 35<br />

Vacon NX_ OPTIONS Other options (Demo cases, Varnished PCB's, DIN rail assembly optionss) 35<br />

Vacon NX_OPTIONS Other material 35<br />

Vacon NXC 380-500 V, 6-pulse supply<br />

Vacon NXC 380-500 V, 261 A, EMC level L/T, air-cooled AC drive, 6-pulse supply 36<br />

Vacon NXC 380-500 V, 300 A, EMC level L/T, air-cooled AC drive, 6-pulse supply 37<br />

Vacon NXC 380-500 V, 385 A, EMC level L/T, air-cooled AC drive, 6-pulse supply 38<br />

Vacon NXC 380-500 V, 460 A, EMC level L/T, air-cooled AC drive, 6-pulse supply 39<br />

Vacon NXC 380-500 V, 520 A, EMC level L/T, air-cooled AC drive, 6-pulse supply 40<br />

Vacon NXC 380-500 V, 590 A, EMC level L/T, air-cooled AC drive, 6-pulse supply 41<br />

Vacon NXC 380-500 V, 650 A, EMC level L/T, air-cooled AC drive, 6-pulse supply 42<br />

Vacon NXC 380-500 V, 730 A, EMC level L/T, air-cooled AC drive, 6-pulse supply 43<br />

Vacon NXC 380-500 V, 820 A, EMC level L/T, air-cooled AC drive, 6-pulse supply 44<br />

Vacon NXC 380-500 V, 920 A, EMC level L/T, air-cooled AC drive, 6-pulse supply 45<br />

Vacon NXC 380-500 V, 1030 A, EMC level L/T, air-cooled AC drive, 6-pulse supply 46<br />

Vacon NXC 380-500 V, 1150 A, EMC level L/T, air-cooled AC drive, 6-pulse supply 47<br />

Vacon NXC 380-500 V, 1300 A, EMC level L/T, air-cooled AC drive, 6-pulse supply 48<br />

Vacon NXC 380-500 V, 1450 A, EMC level L/T, air-cooled AC drive, 6-pulse supply 49<br />

Vacon NXC 380-500 V, 1770 A, EMC level L/T, air-cooled AC drive, 6-pulse supply 50<br />

Vacon NXC 380-500 V, 2150 A, EMC level L/T, air-cooled AC drive, 6-pulse supply 51<br />

Vacon NXC 380-500 V, 12-pulse supply<br />

Vacon NXC 380-500 V, 385 A, EMC level L/T, air-cooled AC drive, 12-pulse supply 52<br />

Vacon NXC 380-500 V, 460 A, EMC level L/T, air-cooled AC drive, 12-pulse supply 53<br />

Vacon NXC 380-500 V, 520 A, EMC level L/T, air-cooled AC drive, 12-pulse supply 54<br />

Vacon NXC 380-500 V, 590 A, EMC level L/T, air-cooled AC drive, 12-pulse supply 55<br />

Vacon NXC 380-500 V, 650 A, EMC level L/T, air-cooled AC drive, 12-pulse supply 56<br />

Vacon NXC 380-500 V, 730 A, EMC level L/T, air-cooled AC drive,12-pulse supply 57<br />

Vacon NXC 380-500 V, 820 A, EMC level L/T, air-cooled AC drive, 12-pulse supply 58<br />

Vacon NXC 380-500 V, 920 A, EMC level L/T, air-cooled AC drive, 12-pulse supply 59<br />

Vacon NXC 380-500 V, 1030 A, EMC level L/T, air-cooled AC drive, 12-pulse supply 60<br />

Vacon NXC 380-500 V, 1150 A, EMC level L/T, air-cooled AC drive, 12-pulse supply 61<br />

Vacon NXC 380-500 V, 1300 A, EMC level L/T, air-cooled AC drive, 12-pulse supply 62<br />

Vacon NXC 380-500 V, 1450 A, EMC level L/T, air-cooled AC drive, 12-pulse supply 63<br />

Vacon NXC 380-500 V, 1770 A, EMC level L/T, air-cooled AC drive, 12-pulse supply 64<br />

Vacon NXC 380-500 V, 2150 A, EMC level L/T, air-cooled AC drive, 12-pulse supply 65<br />

CONDITIONS<br />

PRICE = FCA VAASA, FINLAND (INCOTERMS 2000)<br />

PRICES ARE VALID FROM 1.3.<strong>2007</strong> UNTIL 31.12.<strong>2007</strong>; PRICES DO NOT INCLUDE ANY TAXES OR SIMILAR CHARGES<br />

SUBJECT TO CHANGE WITHOUT NOTICE<br />

Vacon Plc Runsorintie 7 65380 VAASA FINLAND tel.:+358-201-2121 fax: +358 (0)201 212 205 http://www.vacon.com


Vacon Plc<br />

VACON PLC<br />

AC drive 8.2.<strong>2007</strong><br />

TABLE OF CONTENTS<br />

PAGE<br />

Vacon NXC 525-690 V, 6-pulse supply:<br />

Vacon NXC 525-690 V, 125 A, EMC level L/T, air-cooled AC drive, 6-pulse supply 66<br />

Vacon NXC 525-690 V, 144 A, EMC level L/T, air-cooled AC drive, 6-pulse supply 67<br />

Vacon NXC 525-690 V, 170 A, EMC level L/T, air-cooled AC drive, 6-pulse supply 68<br />

Vacon NXC 525-690 V, 208 A, EMC level L/T, air-cooled AC drive, 6-pulse supply 69<br />

Vacon NXC 525-690 V, 261 A, EMC level L/T, air-cooled AC drive, 6-pulse supply 70<br />

Vacon NXC 525-690 V, 325 A, EMC level L/T, air-cooled AC drive, 6-pulse supply 71<br />

Vacon NXC 525-690 V, 385 A, EMC level L/T, air-cooled AC drive, 6-pulse supply 72<br />

Vacon NXC 525-690 V, 416 A, EMC level L/T, air-cooled AC drive, 6-pulse supply 73<br />

Vacon NXC 525-690 V, 460 A, EMC level L/T, air-cooled AC drive, 6-pulse supply 74<br />

Vacon NXC 525-690 V, 502 A, EMC level L/T, air-cooled AC drive, 6-pulse supply 75<br />

Vacon NXC 525-690 V, 590 A, EMC level L/T, air-cooled AC drive, 6-pulse supply 76<br />

Vacon NXC 525-690 V, 650 A, EMC level L/T, air-cooled AC drive, 6-pulse supply 77<br />

Vacon NXC 525-690 V, 750 A, EMC level L/T, air-cooled AC drive, 6-pulse supply 78<br />

Vacon NXC 525-690 V, 820 A, EMC level L/T, air-cooled AC drive, 6-pulse supply 79<br />

Vacon NXC 525-690 V, 920 A, EMC level L/T, air-cooled AC drive, 6-pulse supply 80<br />

Vacon NXC 525-690 V, 1030 A, EMC level L/T, air-cooled AC drive, 6-pulse supply 81<br />

Vacon NXC 525-690 V, 1180 A, EMC level L/T, air-cooled AC drive, 6-pulse supply 82<br />

Vacon NXC 525-690 V, 1500 A, EMC level L/T, air-cooled AC drive, 6-pulse supply 83<br />

Vacon NXC 525-690 V, 1900 A, EMC level L/T, air-cooled AC drive, 6-pulse supply 84<br />

Vacon NXC 525-690 V, 2250 A, EMC level L/T, air-cooled AC drive, 6-pulse supply 85<br />

Vacon NXC 525-690 V, 12-pulse supply:<br />

Vacon NXC 525-690 V, 261 A, EMC level L/T, air-cooled AC drive, 12-pulse supply 86<br />

Vacon NXC 525-690 V, 325 A, EMC level L/T, air-cooled AC drive, 12-pulse supply 87<br />

Vacon NXC 525-690 V, 385 A, EMC level L/T, air-cooled AC drive, 12-pulse supply 88<br />

Vacon NXC 525-690 V, 416 A, EMC level L/T, air-cooled AC drive, 12-pulse supply 89<br />

Vacon NXC 525-690 V, 460 A, EMC level L/T, air-cooled AC drive, 12-pulse supply 90<br />

Vacon NXC 525-690 V, 502 A, EMC level L/T, air-cooled AC drive, 12-pulse supply 91<br />

Vacon NXC 525-690 V, 590 A, EMC level L/T, air-cooled AC drive, 12-pulse supply 92<br />

Vacon NXC 525-690 V, 650 A, EMC level L/T, air-cooled AC drive, 12-pulse supply 93<br />

Vacon NXC 525-690 V, 750 A, EMC level L/T, air-cooled AC drive, 12-pulse supply 94<br />

Vacon NXC 525-690 V, 820 A, EMC level L/T, air-cooled AC drive, 12-pulse supply 95<br />

Vacon NXC 525-690 V, 920 A, EMC level L/T, air-cooled AC drive, 12-pulse supply 96<br />

Vacon NXC 525-690 V, 1030 A, EMC level L/T, air-cooled AC drive, 12-pulse supply 97<br />

Vacon NXC 525-690 V, 1180 A, EMC level L/T, air-cooled AC drive, 12-pulse supply 98<br />

Vacon NXC 525-690 V, 1500 A, EMC level L/T, air-cooled AC drive, 12-pulse supply 99<br />

Vacon NXC 525-690 V, 1900 A, EMC level L/T, air-cooled AC drive, 12-pulse supply 100<br />

Vacon NXC 525-690 V, 2250 A, EMC level L/T, air-cooled AC drive, 12-pulse supply 101<br />

Common Options for Vacon NXC 102<br />

NXP liquid cooled:<br />

Vacon NXP-line 400-500 VAC, IP00, EMC-level N/T, LIQUID COOLED FC, 6-P 103<br />

Vacon NXP-line 400-500 VAC, IP00, EMC-level N/T, LIQUID COOLED FC, 12-P 104<br />

Vacon NXP-line 465-800 VDC, IP00, EMC-level T, LIQUID COOLED INVERTER 105<br />

Vacon NXP-line 525-690 VAC, IP00, EMC-level N/T, LIQUID COOLED FC, 6-P 106<br />

Vacon NXP-line 525-690 VAC, IP00, EMC-level N/T, LIQUID COOLED FC, 12-P 106<br />

Vacon NXP-line 640-1100 VDC, IP00, EMC-level T, LIQUID COOLED INVERTER 107<br />

Vacon Liquid Cooled External Brake chopper units 465-800Vdc & 640-1100Vdc 108<br />

Vacon Liquid Cooled Active Front Ends, Supply Units 465-800Vdc & 640-1100Vdc 109<br />

Vacon Liquid Cooled OPTIONS 110<br />

NX Common DC products:<br />

Vacon NXI-line 380-500 V, IP00, EMC-level T, AIR-COOLED INVERTER UNIT 113<br />

Vacon NXI-line 525-690 V, IP00, EMC-level T, AIR-COOLED INVERTER UNIT 114<br />

Vacon NXA-line 380-500 V, IP00, EMC-level T, AIR-COOLED ACTIVE FRONT-END (AFE) 114<br />

Vacon OPTIONS, LCL filter for AIR-COOLED ACTIVE FRONT-END (AFE) 115<br />

Vacon NXF-line 380-500 V, IP00, EMC-level T, AIR-COOLED FFE UNIT 116<br />

Vacon NXB-line 380-500 V, IP00, EMC-level T, AIR-COOLED INVERTER UNIT 117<br />

Vacon NXB-line 525-690 V, IP00, EMC-level T, AIR-COOLED INVERTER UNIT 118<br />

Type designations codes:<br />

Type designation code for Vacon NXL MF2-MF3 119<br />

Type designation code for Vacon NXL MF4-MF6 120<br />

Type designation code for Vacon NX FR4-FR9 121<br />

Type designation code for Vacon NXP and Vacon NXC FR10-FR13 122<br />

Type designation codes for liquid cooled NX products and Heat exchangers 123<br />

Type designation codes for Common DC products 125<br />

Type designation codes for LCL filters 126<br />

SUBJECT TO CHANGE WITHOUT NOTICE<br />

Vacon Plc Runsorintie 7 65380 VAASA FINLAND tel.:+358-201-2121 fax: +358 (0)201 212 205 http://www.vacon.com


Vacon Plc<br />

AC drive<br />

VACON PLC<br />

Vacon NXL 380-500 V, IP20 (cabinet assembly), EMC level N, air-cooled AC drive<br />

ORDER TYPE CODE MOTOR SHAFT POWER AND CURRENT SIZE/PROT. DIMENSIONS WEIGHT<br />

High overload Low overload FR/IP W x H x D<br />

P [kW] I(H) I(overload) P [kW] I(L) [mm] [kg]<br />

NXL00015C1N0SSS 0,37 1,3 2 0,55 1,9 MF2/IP20 60x130x150 1<br />

NXL00025C1N0SSS 0,55 1,9 2,9 0,75 2,4 MF2/IP20 60x130x150 1<br />

NXL00035C1N1SSS 0,75 2,4 3,6 1,1 3,3 MF3/IP20 84x220x172 2<br />

NXL00045C1N1SSS 1,1 3,3 5 1,5 4,3 MF3/IP20 84x220x172 2<br />

NXL00055C1N1SSS 1,5 4,3 6,5 2,2 5,4 MF3/IP20 84x220x172 2<br />

Vacon NXL 208-240 V, IP20 (cabinet assembly), EMC level N, air-cooled AC drive<br />

ORDER TYPE CODE MOTOR SHAFT POWER AND CURRENT SIZE/PROT. DIMENSIONS WEIGHT<br />

High overload Low overload FR/IP W x H x D<br />

P [kW] I(H) I(overload) P [kW] I(L) [mm] [kg]<br />

NXL00022C1N0SSS 0,25 1,7 2,6 0,37 2,4 MF2/IP20 60x130x150 1<br />

NXL00032C1N1SSS 0,55 2,8 4,2 0,75 3,7 MF3/IP20 84x220x172 2<br />

NXL00042C1N1SSS 0,75 3,7 5,6 1,1 4,8 MF3/IP20 84x220x172 2<br />

NXL00062C1N1SSS 1,1 4,8 7,2 1,5 6,6 MF3/IP20 84x220x172 2<br />

NXL00022C1N0SSS: SINGLE PHASE SUPPLY ONLY<br />

NXL00032C1N1SSS - NXL00062C1N1SSS: BOTH SINGLE AND THREE PHASE SUPPLY POSSIBLE<br />

I(H) = nominal current for 150% overload requirement (at max. 50°C ambient temperature)<br />

I(L) = nominal current for 110% overload requirement (at max. 40°C ambient temperature)<br />

I(overload) = maximum 1 min/10 min overload current (high overload)<br />

SUBJECT TO CHANGE WITHOUT NOTICE<br />

Vacon Plc Runsorintie 7 65380 VAASA FINLAND tel.:+358-201-2121 fax: +358 (0)201 212 205 http://www.vacon.com 1


Vacon Plc<br />

AC drive<br />

VACON PLC<br />

Vacon NXL 380-500 V, IP21, EMC level H, air-cooled AC drive<br />

ORDER TYPE CODE MOTOR SHAFT POWER AND CURRENT SIZE/PROT. DIMENSIONS WEIGHT<br />

High overload Low overload FR/IP W x H x D<br />

P [kW] I(H) I(overload) P [kW] I(L) [mm] [kg]<br />

NXL00035C2H1SSS 0,75 2,2 3,3 1,1 3,3 MF4/IP21 128x292x190 5<br />

NXL00045C2H1SSS 1,1 3,3 5 1,5 4,3 MF4/IP21 128x292x190 5<br />

NXL00055C2H1SSS 1,5 4,3 6,5 2,2 5,6 MF4/IP21 128x292x190 5<br />

NXL00075C2H1SSS 2,2 5,6 8,4 3 7,6 MF4/IP21 128x292x190 5<br />

NXL00095C2H1SSS 3 7,6 11,4 4 9 MF4/IP21 128x292x190 5<br />

NXL00125C2H1SSS 4 9 13,5 5,5 12 MF4/IP21 128x292x190 5<br />

NXL00165C2H1SSS 5,5 12 18 7,5 16 MF5/IP21 144x391x214 8,1<br />

NXL00235C2H1SSS 7,5 16 24 11 23 MF5/IP21 144x391x214 8,1<br />

NXL00315C2H1SSS 11 23 35 15 31 MF5/IP21 144x391x214 8,1<br />

NXL00385C2H1SSS 15 31 47 18,5 38 MF6/IP21 195x519x237 18,5<br />

NXL00465C2H1SSS 18,5 38 57 22 46 MF6/IP21 195x519x237 18,5<br />

NXL00615C2H1SSS 22 46 69 30 61 MF6/IP21 195x519x237 18,5<br />

Vacon NXL 380-500 V, IP54, EMC level H, air-cooled AC drive<br />

ORDER TYPE CODE MOTOR SHAFT POWER AND CURRENT SIZE/PROT. DIMENSIONS WEIGHT<br />

High overload Low overload FR/IP W x H x D<br />

P [kW] I(H) I(overload) P [kW] I(L) [mm] [kg]<br />

NXL00035C5H1SSS 0,75 2,2 3,3 1,1 3,3 MF4/IP54 128x292x190 5<br />

NXL00045C5H1SSS 1,1 3,3 5 1,5 4,3 MF4/IP54 128x292x190 5<br />

NXL00055C5H1SSS 1,5 4,3 6,5 2,2 5,6 MF4/IP54 128x292x190 5<br />

NXL00075C5H1SSS 2,2 5,6 8,4 3 7,6 MF4/IP54 128x292x190 5<br />

NXL00095C5H1SSS 3 7,6 11,4 4 9 MF4/IP54 128x292x190 5<br />

NXL00125C5H1SSS 4 9 13,5 5,5 12 MF4/IP54 128x292x190 5<br />

NXL00165C5H1SSS 5,5 12 18 7,5 16 MF5/IP54 144x391x214 8,1<br />

NXL00235C5H1SSS 7,5 16 24 11 23 MF5/IP54 144x391x214 8,1<br />

NXL00315C5H1SSS 11 23 35 15 31 MF5/IP54 144x391x214 8,1<br />

NXL00385C5H1SSS 15 31 47 18,5 38 MF6/IP54 195x519x237 18,5<br />

NXL00465C5H1SSS 18,5 38 57 22 46 MF6/IP54 195x519x237 18,5<br />

NXL00615C5H1SSS 22 46 69 30 61 MF6/IP54 195x519x237 18,5<br />

I(H) = nominal current for 150% overload requirement (at max. 50°C ambient temperature)<br />

I(L) = nominal current for 110% overload requirement (at max. 40°C ambient temperature)<br />

I(overload) = maximum 1 min/10 min overload current (high overload)<br />

Vacon NXL 380-500 V, IP21 and IP54, EMC level T, air-cooled AC drive<br />

The prices are the same as H level ones.<br />

Replace the H by T in the order typecode.<br />

SUBJECT TO CHANGE WITHOUT NOTICE<br />

Vacon Plc Runsorintie 7 65380 VAASA FINLAND tel.:+358-201-2121 fax: +358 (0)201 212 205 http://www.vacon.com 2


Vacon Plc<br />

AC drive<br />

VACON PLC<br />

Vacon NXS 208-240 V (3 phase supply), IP21, EMC level H, air-cooled AC drive<br />

ORDER TYPE CODE MOTOR SHAFT POWER AND CURRENT SIZE/PROT. DIMENSIONS WEIGHT<br />

High overload Low overload FR/IP W x H x D<br />

P [kW] I(H) I(overload) P [kW] I(L) [mm] [kg]<br />

NXS00042A2H1SSSA1A2 0,55 3,7 5,6 0,75 4,8 FR4/IP21 128x292x190 5<br />

NXS00072A2H1SSSA1A2 0,75 4,8 7,2 1,1 6,6 FR4/IP21 128x292x190 5<br />

NXS00082A2H1SSSA1A2 1,1 6,6 9,9 1,5 7,8 FR4/IP21 128x292x190 5<br />

NXS00112A2H1SSSA1A2 1,5 7,8 11,7 2,2 11 FR4/IP21 128x292x190 5<br />

NXS00122A2H1SSSA1A2 2,2 11 16,5 3 12,5 FR4/IP21 128x292x190 5<br />

NXS00172A2H1SSSA1A2 3 12,5 18,8 4 17,5 FR5/IP21 144x391x214 8,1<br />

NXS00252A2H1SSSA1A2 4 17,5 26,3 5,5 25 FR5/IP21 144x391x214 8,1<br />

NXS00312A2H1SSSA1A2 5,5 25 37,5 7,5 31 FR5/IP21 144x391x214 8,1<br />

NXS00482A2H1SSSA1A2 7,5 31 46,5 11 48 FR6/IP21 195x519x237 18,5<br />

NXS00612A2H1SSSA1A2 11 48 72,0 15 61 FR6/IP21 195x519x237 18,5<br />

NXS00752A2H0SSSA1A2 15 61 91,5 18,5 75 FR7/IP21 237x591x257 35<br />

NXS00882A2H0SSSA1A2 18,5 75 112,5 22 88 FR7/IP21 237x591x257 35<br />

NXS01142A2H0SSSA1A2 22 88 132,0 30 114 FR7/IP21 237x591x257 35<br />

NXS01402A2H0SSSA1A2 30 105 158 37 140 FR8/IP21 291x758x344 58<br />

NXS01702A2H0SSSA1A2 37 140 210 45 170 FR8/IP21 291x758x344 58<br />

NXS02052A2H0SSSA1A2 45 170 255 55 205 FR8/IP21 291x758x344 58<br />

NXS02612A2H0SSFA1A2 55 205 308 75 261 FR9/IP21 480x1150x362 146<br />

NXS03002A2H0SSFA1A2 75 245 368 90 300 FR9/IP21 480x1150x362 146<br />

I(H) = nominal current for 150% overload requirement (at max. 50°C ambient temperature)<br />

I(L) = nominal current for 110% overload requirement (at max. 40°C ambient temperature)<br />

I(overload) = maximum 1 min/10 min overload current (high overload)<br />

Vacon NXS 208-240 V, IP21, EMC level T, air-cooled AC drive<br />

The prices are the same as H level ones.<br />

Replace the H by T in the order typecode.<br />

SUBJECT TO CHANGE WITHOUT NOTICE<br />

Vacon Plc Runsorintie 7 65380 VAASA FINLAND tel.:+358-201-2121 fax: +358 (0)201 212 205 http://www.vacon.com 3


Vacon Plc<br />

AC drive<br />

VACON PLC<br />

Vacon NXS 208-240 V (3 phase supply), IP54, EMC level H, air-cooled AC drive<br />

ORDER TYPE CODE MOTOR SHAFT POWER AND CURRENT SIZE/PROT. DIMENSIONS WEIGHT<br />

High overload Low overload FR/IP W x H x D<br />

P [kW] I(H) I(overload) P [kW] I(L) [mm] [kg]<br />

NXS00042A5H1SSSA1A2 0,55 3,7 5,6 0,75 4,8 FR4/IP54 128x292x190 5<br />

NXS00072A5H1SSSA1A2 0,75 4,8 7,2 1,1 6,6 FR4/IP54 128x292x190 5<br />

NXS00082A5H1SSSA1A2 1,1 6,6 9,9 1,5 7,8 FR4/IP54 128x292x190 5<br />

NXS00112A5H1SSSA1A2 1,5 7,8 11,7 2,2 11 FR4/IP54 128x292x190 5<br />

NXS00122A5H1SSSA1A2 2,2 11 16,5 3 12,5 FR4/IP54 128x292x190 5<br />

NXS00172A5H1SSSA1A2 3 12,5 18,8 4 17,5 FR5/IP54 144x391x214 8,1<br />

NXS00252A5H1SSSA1A2 4 17,5 26,3 5,5 25 FR5/IP54 144x391x214 8,1<br />

NXS00312A5H1SSSA1A2 5,5 25 37,5 7,5 31 FR5/IP54 144x391x214 8,1<br />

NXS00482A5H1SSSA1A2 7,5 31 46,5 11 48 FR6/IP54 195x519x237 18,5<br />

NXS00612A5H1SSSA1A2 11 48 72,0 15 61 FR6/IP54 195x519x237 18,5<br />

NXS00752A5H0SSSA1A2 15 61 91,5 18,5 75 FR7/IP54 237x591x257 35<br />

NXS00882A5H0SSSA1A2 18,5 75 112,5 22 88 FR7/IP54 237x591x257 35<br />

NXS01142A5H0SSSA1A2 22 88 132,0 30 114 FR7/IP54 237x591x257 35<br />

NXS01402A5H0SSSA1A2 30 105 158 37 140 FR8/IP54 291x758x344 58<br />

NXS01702A5H0SSSA1A2 37 140 210 45 170 FR8/IP54 291x758x344 58<br />

NXS02052A5H0SSSA1A2 45 170 255 55 205 FR8/IP54 291x758x344 58<br />

NXS02612A5H0SSFA1A2 55 205 308 75 261 FR9/IP54 480x1150x362 146<br />

NXS03002A5H0SSFA1A2 75 245 368 90 300 FR9/IP54 480x1150x362 146<br />

I(H) = nominal current for 150% overload requirement (at max. 50°C ambient temperature)<br />

I(L) = nominal current for 110% overload requirement (at max. 40°C ambient temperature)<br />

I(overload) = maximum 1 min/10 min overload current (high overload)<br />

Vacon NXS 208-240 V, IP54, EMC level T, air-cooled AC drive<br />

The prices are the same as H level ones.<br />

Replace the H by T in the order typecode.<br />

SUBJECT TO CHANGE WITHOUT NOTICE<br />

Vacon Plc Runsorintie 7 65380 VAASA FINLAND tel.:+358-201-2121 fax: +358 (0)201 212 205 http://www.vacon.com 4


Vacon Plc<br />

AC drive<br />

VACON PLC<br />

Vacon NXS 380-500 V, IP21, EMC level H, air-cooled AC drive<br />

ORDER TYPE CODE MOTOR SHAFT POWER AND CURRENT SIZE/PROT. DIMENSIONS WEIGHT<br />

High overload Low overload FR/IP W x H x D<br />

P [kW] I(H) I(overload) P [kW] I(L) [mm] [kg]<br />

NXS00035A2H1SSSA1A2 0,75 2,2 3,3 1,1 3,3 FR4/IP21 128x292x190 5<br />

NXS00045A2H1SSSA1A2 1,1 3,3 5 1,5 4,3 FR4/IP21 128x292x190 5<br />

NXS00055A2H1SSSA1A2 1,5 4,3 6,5 2,2 5,6 FR4/IP21 128x292x190 5<br />

NXS00075A2H1SSSA1A2 2,2 5,6 8,4 3 7,6 FR4/IP21 128x292x190 5<br />

NXS00095A2H1SSSA1A2 3 7,6 11,4 4 9 FR4/IP21 128x292x190 5<br />

NXS00125A2H1SSSA1A2 4 9 13,5 5,5 12 FR4/IP21 128x292x190 5<br />

NXS00165A2H1SSSA1A2 5,5 12 18 7,5 16 FR5/IP21 144x391x214 8,1<br />

NXS00225A2H1SSSA1A2 7,5 16 24 11 23 FR5/IP21 144x391x214 8,1<br />

NXS00315A2H1SSSA1A2 11 23 35 15 31 FR5/IP21 144x391x214 8,1<br />

NXS00385A2H1SSSA1A2 15 31 47 18,5 38 FR6/IP21 195x519x237 18,5<br />

NXS00455A2H1SSSA1A2 18,5 38 57 22 46 FR6/IP21 195x519x237 18,5<br />

NXS00615A2H1SSSA1A2 22 46 69 30 61 FR6/IP21 195x519x237 18,5<br />

NXS00725A2H0SSSA1A2 30 61 92 37 72 FR7/IP21 237x591x257 35<br />

NXS00875A2H0SSSA1A2 37 72 108 45 87 FR7/IP21 237x591x257 35<br />

NXS01055A2H0SSSA1A2 45 87 131 55 105 FR7/IP21 237x591x257 35<br />

NXS01405A2H0SSSA1A2 55 105 158 75 140 FR8/IP21 291x758x344 58<br />

NXS01685A2H0SSSA1A2 75 140 210 90 170 FR8/IP21 291x758x344 58<br />

NXS02055A2H0SSSA1A2 90 170 255 110 205 FR8/IP21 291x758x344 58<br />

NXS02615A2H0SSFA1A2 110 205 308 132 261 FR9/IP21 480x1150x362 146<br />

NXS03005A2H0SSFA1A2 132 245 368 160 300 FR9/IP21 480x1150x362 146<br />

I(H) = nominal current for 150% overload requirement (at max. 50°C ambient temperature)<br />

I(L) = nominal current for 110% overload requirement (at max. 40°C ambient temperature)<br />

I(overload) = maximum 1 min/10 min overload current (high overload)<br />

Vacon NXS 380-500 V, IP21, EMC level T, air-cooled AC drive<br />

The prices are the same as H level ones.<br />

Replace the H by T in the order typecode.<br />

SUBJECT TO CHANGE WITHOUT NOTICE<br />

Vacon Plc Runsorintie 7 65380 VAASA FINLAND tel.:+358-201-2121 fax: +358 (0)201 212 205 http://www.vacon.com 5


Vacon Plc<br />

AC drive<br />

VACON PLC<br />

Vacon NXS 380-500 V, IP54, EMC level H, air-cooled AC drive<br />

ORDER TYPE CODE MOTOR SHAFT POWER AND CURRENT SIZE/PROT. DIMENSIONS WEIGHT<br />

High overload Low overload FR/IP W x H x D<br />

P [kW] I(H) I(overload) P [kW] I(L) [mm] [kg]<br />

NXS00035A5H1SSSA1A2 0,75 2,2 3,3 1,1 3,3 FR4/IP54 128x292x190 5<br />

NXS00045A5H1SSSA1A2 1,1 3,3 5 1,5 4,3 FR4/IP54 128x292x190 5<br />

NXS00055A5H1SSSA1A2 1,5 4,3 6,5 2,2 5,6 FR4/IP54 128x292x190 5<br />

NXS00075A5H1SSSA1A2 2,2 5,6 8,4 3 7,6 FR4/IP54 128x292x190 5<br />

NXS00095A5H1SSSA1A2 3 7,6 11,4 4 9 FR4/IP54 128x292x190 5<br />

NXS00125A5H1SSSA1A2 4 9 13,5 5,5 12 FR4/IP54 128x292x190 5<br />

NXS00165A5H1SSSA1A2 5,5 12 18 7,5 16 FR5/IP54 144x391x214 8,1<br />

NXS00225A5H1SSSA1A2 7,5 16 24 11 23 FR5/IP54 144x391x214 8,1<br />

NXS00315A5H1SSSA1A2 11 23 35 15 31 FR5/IP54 144x391x214 8,1<br />

NXS00385A5H1SSSA1A2 15 31 47 18,5 38 FR6/IP54 195x519x237 18,5<br />

NXS00455A5H1SSSA1A2 18,5 38 57 22 46 FR6/IP54 195x519x237 18,5<br />

NXS00615A5H1SSSA1A2 22 46 69 30 61 FR6/IP54 195x519x237 18,5<br />

NXS00725A5H0SSSA1A2 30 61 92 37 72 FR7/IP54 237x591x257 35<br />

NXS00875A5H0SSSA1A2 37 72 108 45 87 FR7/IP54 237x591x257 35<br />

NXS01055A5H0SSSA1A2 45 87 131 55 105 FR7/IP54 237x591x257 35<br />

NXS01405A5H0SSSA1A2 55 105 158 75 140 FR8/IP54 291x758x344 58<br />

NXS01685A5H0SSSA1A2 75 140 210 90 170 FR8/IP54 291x758x344 58<br />

NXS02055A5H0SSSA1A2 90 170 255 110 205 FR8/IP54 291x758x344 58<br />

NXS02615A5H0SSFA1A2 110 205 308 132 261 FR9/IP54 480x1150x362 146<br />

NXS03005A5H0SSFA1A2 132 245 368 160 300 FR9/IP54 480x1150x362 146<br />

I(H) = nominal current for 150% overload requirement (at max. 50°C ambient temperature)<br />

I(L) = nominal current for 110% overload requirement (at max. 40°C ambient temperature)<br />

I(overload) = maximum 1 min/10 min overload current (high overload)<br />

Vacon NXS 380-500 V, IP54, EMC level T, air-cooled AC drive<br />

The prices are the same as H level ones.<br />

Replace the H by T in the order typecode.<br />

SUBJECT TO CHANGE WITHOUT NOTICE<br />

Vacon Plc Runsorintie 7 65380 VAASA FINLAND tel.:+358-201-2121 fax: +358 (0)201 212 205 http://www.vacon.com 6


Vacon Plc<br />

AC drive<br />

VACON PLC<br />

Vacon NXS 525-690 V, IP21, EMC level L, air-cooled AC drive<br />

ORDER TYPE CODE MOTOR SHAFT POWER AND CURRENT SIZE/PROT. DIMENSIONS WEIGHT<br />

High overload Low overload FR/IP W x H x D<br />

P [kW] I(H) I(overload) P [kW] I(L) [mm] [kg]<br />

NXS00046A2L0SSSA1A2 2,2 3,2 5,0 3 4,5 FR6/IP21 195x519x237 18,5<br />

NXS00056A2L0SSSA1A2 3 4,5 6,8 4 5,5 FR6/IP21 195x519x237 18,5<br />

NXS00076A2L0SSSA1A2 4 5,5 8,3 5,5 7,5 FR6/IP21 195x519x237 18,5<br />

NXS00106A2L0SSSA1A2 5,5 7,5 11,3 7,5 10 FR6/IP21 195x519x237 18,5<br />

NXS00136A2L0SSSA1A2 7,5 10 15 11 13,5 FR6/IP21 195x519x237 18,5<br />

NXS00186A2L0SSSA1A2 11 13,5 20,3 15 18 FR6/IP21 195x519x237 18,5<br />

NXS00226A2L0SSSA1A2 15 18 27,0 18,5 22 FR6/IP21 195x519x237 18,5<br />

NXS00276A2L0SSSA1A2 18,5 22 33 22 27 FR6/IP21 195x519x237 18,5<br />

NXS00346A2L0SSSA1A2 22 27 41 30 34 FR6/IP21 195x519x237 18,5<br />

NXS00416A2L0SSSA1A2 30 34 51 37 41 FR7/IP21 237x591x257 35<br />

NXS00526A2L0SSSA1A2 37 41 62 45 52 FR7/IP21 237x591x257 35<br />

NXS00626A2L0SSSA1A2 45 52 78 55 62 FR8/IP21 291x758x344 58<br />

NXS00806A2L0SSSA1A2 55 62 93 75 80 FR8/IP21 291x758x344 58<br />

NXS01006A2L0SSSA1A2 75 80 120 90 100 FR8/IP21 291x758x344 58<br />

NXS01256A2L0SSFA1A2 90 100 150 110 125 FR9/IP21 480x1150x362 146<br />

NXS01446A2L0SSFA1A2 110 125 188 132 144 FR9/IP21 480x1150x362 146<br />

NXS01706A2L0SSFA1A2 132 144 216 160 170 FR9/IP21 480x1150x362 146<br />

NXS02086A2L0SSFA1A2 160 170 255 200 208 FR9/IP21 480x1150x362 146<br />

I(H) = nominal current for 150% overload requirement (at max. 50°C ambient temperature)<br />

I(L) = nominal current for 110% overload requirement (at max. 40°C ambient temperature)<br />

I(overload) = maximum 1 min/10 min overload current (high overload)<br />

Vacon NXS 525-690 V, IP21, EMC level T, air-cooled AC drive<br />

The prices are the same as L level ones.<br />

Replace the L by T in the Order Type Code<br />

SUBJECT TO CHANGE WITHOUT NOTICE<br />

Vacon Plc Runsorintie 7 65380 VAASA FINLAND tel.:+358-201-2121 fax: +358 (0)201 212 205 http://www.vacon.com 7


Vacon Plc<br />

AC drive<br />

VACON PLC<br />

Vacon NXS 525-690 V, IP54, EMC level L, air-cooled AC drive<br />

ORDER TYPE CODE MOTOR SHAFT POWER AND CURRENT SIZE/PROT. DIMENSIONS WEIGHT<br />

High overload Low overload FR/IP W x H x D<br />

P [kW] I(H) I(overload) P [kW] I(L) [mm] [kg]<br />

NXS00046A5L0SSSA1A2 2,2 3,2 5,0 3 4,5 FR6/IP54 195x519x237 18,5<br />

NXS00056A5L0SSSA1A2 3 4,5 6,8 4 5,5 FR6/IP54 195x519x237 18,5<br />

NXS00076A5L0SSSA1A2 4 5,5 8,3 5,5 7,5 FR6/IP54 195x519x237 18,5<br />

NXS00106A5L0SSSA1A2 5,5 7,5 11,3 7,5 10 FR6/IP54 195x519x237 18,5<br />

NXS00136A5L0SSSA1A2 7,5 10 15 11 13,5 FR6/IP54 195x519x237 18,5<br />

NXS00186A5L0SSSA1A2 11 13,5 20,3 15 18 FR6/IP54 195x519x237 18,5<br />

NXS00226A5L0SSSA1A2 15 18 27,0 18,5 22 FR6/IP54 195x519x237 18,5<br />

NXS00276A5L0SSSA1A2 18,5 22 33 22 27 FR6/IP54 195x519x237 18,5<br />

NXS00346A5L0SSSA1A2 22 27 41 30 34 FR6/IP54 195x519x237 18,5<br />

NXS00416A5L0SSSA1A2 30 34 51 37 41 FR7/IP54 237x591x257 35<br />

NXS00526A5L0SSSA1A2 37 41 62 45 52 FR7/IP54 237x591x257 35<br />

NXS00626A5L0SSSA1A2 45 52 78 55 62 FR8/IP54 291x758x344 58<br />

NXS00806A5L0SSSA1A2 55 62 93 75 80 FR8/IP54 291x758x344 58<br />

NXS01006A5L0SSSA1A2 75 80 120 90 100 FR8/IP54 289x759x344 58<br />

NXS01256A5L0SSFA1A2 90 100 150 110 125 FR9/IP54 480x1150x362 146<br />

NXS01446A5L0SSFA1A2 110 125 188 132 144 FR9/IP54 480x1150x362 146<br />

NXS01706A5L0SSFA1A2 132 144 216 160 170 FR9/IP54 480x1150x362 146<br />

NXS02086A5L0SSFA1A2 160 170 255 200 208 FR9/IP54 480x1150x362 146<br />

I(H) = nominal current for 150% overload requirement (at max. 50°C ambient temperature)<br />

I(L) = nominal current for 110% overload requirement (at max. 40°C ambient temperature)<br />

I(overload) = maximum 1 min/10 min overload current (high overload)<br />

Vacon NXS 525-690 V, IP54, EMC level T, air-cooled AC drive<br />

The prices are the same as L level ones.<br />

Replace the L by T in the order typecode.<br />

SUBJECT TO CHANGE WITHOUT NOTICE<br />

Vacon Plc Runsorintie 7 65380 VAASA FINLAND tel.:+358-201-2121 fax: +358 (0)201 212 205 http://www.vacon.com 8


Vacon Plc<br />

AC drive<br />

VACON PLC<br />

Vacon NXS 380-500 V, IP21, EMC level L, air-cooled standalone AC drive<br />

ORDER TYPE CODE MOTOR SHAFT POWER AND CURRENT SIZE/PROT. DIMENSIONS WEIGHT<br />

High overload Low overload FR/IP W x H x D<br />

P [kW] I(H) I(overload) P [kW] I(L) [mm] [kg]<br />

NXS03855A2L0SSAA1A2 160 300 450 200 385 FR10/IP21 595x2018x602 340<br />

NXS04605A2L0SSAA1A2 200 385 578 250 460 FR10/IP21 595x2018x602 340<br />

NXS05205A2L0SSAA1A2 250 460 690 250 520 FR10/IP21 595x2018x602 340<br />

NXS05905A2L0SSAA1A2 250 520 780 315 590 FR11/IP21 794x2018x602 470<br />

NXS06505A2L0SSAA1A2 315 590 885 355 650 FR11/IP21 794x2018x602 470<br />

NXS07305A2L0SSAA1A2 355 650 975 400 730 FR11/IP21 794x2018x602 470<br />

Input fuses are included as standard<br />

I(H) = nominal current for 150% overload requirement (at max. 40°C ambient temperature)<br />

I(L) = nominal current for 110% overload requirement (at max. 40°C ambient temperature)<br />

I(overload) = maximum 1 min/10 min overload current (high overload)<br />

VACON NX_ OPTIONS Integrated load switch for standalone units<br />

ORDER TYPE CODE SUITABILITY DESCRIPTION<br />

NXS_________O__ FR10 standalone Integrated load switch for standalone<br />

NXS_________O__ FR11 standalone Integrated load switch for standalone<br />

Vacon NXS 380-500 V, IP21, EMC level T, air-cooled standalone AC drive<br />

The prices are the same as L level ones.<br />

Replace the L by T in the order typecode.<br />

SUBJECT TO CHANGE WITHOUT NOTICE<br />

Vacon Plc Runsorintie 7 65380 VAASA FINLAND tel.:+358-201-2121 fax: +358 (0)201 212 205 http://www.vacon.com 9


Vacon Plc<br />

AC drive<br />

VACON PLC<br />

Vacon NXS 380-500 V, IP54, EMC level L, air-cooled standalone AC drive<br />

ORDER TYPE CODE MOTOR SHAFT POWER AND CURRENT SIZE/PROT. DIMENSIONS WEIGHT<br />

High overload Low overload FR/IP W x H x D<br />

P [kW] I(H) I(overload) P [kW] I(L) [mm] [kg]<br />

NXS03855A5L0SSAA1A2 160 300 450 200 385 FR10/IP54 595x2018x602 340<br />

NXS04605A5L0SSAA1A2 200 385 578 250 460 FR10/IP54 595x2018x602 340<br />

NXS05205A5L0SSAA1A2 250 460 690 250 520 FR10/IP54 595x2018x602 340<br />

Input fuses are included as standard<br />

I(H) = nominal current for 150% overload requirement (at max. 40°C ambient temperature)<br />

I(L) = nominal current for 110% overload requirement (at max. 40°C ambient temperature)<br />

I(overload) = maximum 1 min/10 min overload current (high overload)<br />

VACON NX_ OPTIONS Integrated load switch for standalone units<br />

ORDER TYPE CODE SUITABILITY DESCRIPTION<br />

NXS_________O__ NXS FR10 standalone Integrated load switch for standalone<br />

Vacon NXS 380-500 V, IP54, EMC level T, air-cooled standalone AC drive<br />

The prices are the same as L level ones.<br />

Replace the L by T in the order typecode.<br />

SUBJECT TO CHANGE WITHOUT NOTICE<br />

Vacon Plc Runsorintie 7 65380 VAASA FINLAND tel.:+358-201-2121 fax: +358 (0)201 212 205 http://www.vacon.com 10


Vacon Plc<br />

AC drive<br />

VACON PLC<br />

Vacon NXS 525-690 V, IP21, EMC level L, air-cooled standalone AC drive<br />

ORDER TYPE CODE MOTOR SHAFT POWER AND CURRENT SIZE/PROT. DIMENSIONS WEIGHT<br />

High overload Low overload FR/IP W x H x D<br />

P [kW] I(H) I(overload) P [kW] I(L) [mm] [kg]<br />

NXS02616A2L0SSAA1A2 200 208 312 250 261 FR10/IP21 595x2020x602 340<br />

NXS03256A2L0SSAA1A2 250 261 392 315 325 FR10/IP21 595x2020x602 340<br />

NXS03856A2L0SSAA1A2 315 325 488 355 385 FR10/IP21 595x2020x602 340<br />

NXS04166A2L0SSAA1A2 315 325 488 400 416 FR10/IP21 595x2020x602 340<br />

NXS04606A2L0SSAA1A2 355 385 578 450 460 FR11/IP21 794x2018x602 400<br />

NXS05026A2L0SSAA1A2 450 460 690 500 502 FR11/IP21 794x2018x602 400<br />

NXS05906A2L0SSAA1A2 500 502 753 560 590 FR11/IP21 794x2018x602 470<br />

Input fuses are included as standard<br />

I(H) = nominal current for 150% overload requirement (at max. 40°C ambient temperature)<br />

I(L) = nominal current for 110% overload requirement (at max. 40°C ambient temperature)<br />

I(overload) = maximum 1 min/10 min overload current (high overload)<br />

VACON NX_ OPTIONS Integrated load switch for standalone units<br />

ORDER TYPE CODE SUITABILITY DESCRIPTION<br />

NXS_________O__ FR10 standalone Integrated load switch for standalone<br />

NXS_________O__ FR11 standalone Integrated load switch for standalone<br />

Vacon NXS 525-690 V, IP21, EMC level T, air-cooled standalone AC drive<br />

The prices are the same as L level ones.<br />

Replace the L by T in the order typecode.<br />

SUBJECT TO CHANGE WITHOUT NOTICE<br />

Vacon Plc Runsorintie 7 65380 VAASA FINLAND tel.:+358-201-2121 fax: +358 (0)201 212 205 http://www.vacon.com 11


Vacon Plc<br />

AC drive<br />

VACON PLC<br />

Vacon NXS 525-690 V, IP54, EMC level L, air-cooled standalone AC drive<br />

ORDER TYPE CODE MOTOR SHAFT POWER AND CURRENT SIZE/PROT. DIMENSIONS WEIGHT<br />

High overload Low overload FR/IP W x H x D<br />

P [kW] I(H) I(overload) P [kW] I(L) [mm] [kg]<br />

NXS02616A5L0SSAA1A2 200 208 312 250 261 FR10/IP54 595x2020x602 340<br />

NXS03256A5L0SSAA1A2 250 261 392 315 325 FR10/IP54 595x2020x602 340<br />

NXS03856A5L0SSAA1A2 315 325 488 355 385 FR10/IP54 595x2020x602 340<br />

NXS04166A5L0SSAA1A2 315 325 488 400 416 FR10/IP54 595x2020x602 340<br />

Input fuses are included as standard<br />

I(H) = nominal current for 150% overload requirement (at max. 40°C ambient temperature)<br />

I(L) = nominal current for 110% overload requirement (at max. 40°C ambient temperature)<br />

I(overload) = maximum 1 min/10 min overload current (high overload)<br />

VACON NX_ OPTIONS Integrated load switch for standalone units<br />

ORDER TYPE CODE SUITABILITY DESCRIPTION<br />

NXS_________O__ FR10 standalone Integrated load switch for standalone<br />

Vacon NXS 525-690 V, IP54, EMC level T, air-cooled standalone AC drive<br />

The prices are the same as L level ones.<br />

Replace the L by T in the order typecode.<br />

SUBJECT TO CHANGE WITHOUT NOTICE<br />

Vacon Plc Runsorintie 7 65380 VAASA FINLAND tel.:+358-201-2121 fax: +358 (0)201 212 205 http://www.vacon.com 12


Vacon Plc<br />

AC drive<br />

VACON PLC<br />

Vacon NXP 208-240 V (3 phase supply), IP21, EMC level H, air-cooled AC drive<br />

ORDER TYPE CODE MOTOR SHAFT POWER AND CURRENT SIZE/PROT. DIMENSIONS WEIGHT<br />

High overload Low overload FR/IP W x H x D<br />

P [kW] I(H) I(overload) P [kW] I(L) [mm] [kg]<br />

NXP00042A2H1SSSA1A2 0,55 3,7 5,6 0,75 4,8 FR4/IP21 128x292x190 5<br />

NXP00072A2H1SSSA1A2 0,75 4,8 7,2 1,1 6,6 FR4/IP21 128x292x190 5<br />

NXP00082A2H1SSSA1A2 1,1 6,6 9,9 1,5 7,8 FR4/IP21 128x292x190 5<br />

NXP00112A2H1SSSA1A2 1,5 7,8 11,7 2,2 11 FR4/IP21 128x292x190 5<br />

NXP00122A2H1SSSA1A2 2,2 11 16,5 3 12,5 FR4/IP21 128x292x190 5<br />

NXP00172A2H1SSSA1A2 3 12,5 18,8 4 17,5 FR5/IP21 144x391x214 8,1<br />

NXP00252A2H1SSSA1A2 4 17,5 26,3 5,5 25 FR5/IP21 144x391x214 8,1<br />

NXP00312A2H1SSSA1A2 5,5 25 37,5 7,5 31 FR5/IP21 144x391x214 8,1<br />

NXP00482A2H1SSSA1A2 7,5 31 46,5 11 48 FR6/IP21 195x519x237 18,5<br />

NXP00612A2H1SSSA1A2 11 48 72,0 15 61 FR6/IP21 195x519x237 18,5<br />

NXP00752A2H0SSSA1A2 15 61 91,5 18,5 75 FR7/IP21 237x591x257 35<br />

NXP00882A2H0SSSA1A2 18,5 75 112,5 22 88 FR7/IP21 237x591x257 35<br />

NXP01142A2H0SSSA1A2 22 88 132,0 30 114 FR7/IP21 237x591x257 35<br />

NXP01402A2H0SSSA1A2 30 105 158 37 140 FR8/IP21 291x758x344 58<br />

NXP01702A2H0SSSA1A2 37 140 210 45 170 FR8/IP21 291x758x344 58<br />

NXP02052A2H0SSSA1A2 45 170 255 55 205 FR8/IP21 291x758x344 58<br />

NXP02612A2H0SSFA1A2 55 205 308 75 261 FR9/IP21 480x1150x362 146<br />

NXP03002A2H0SSFA1A2 75 245 368 90 300 FR9/IP21 480x1150x362 146<br />

I(H) = nominal current for 150% overload requirement (at max. 50°C ambient temperature)<br />

I(L) = nominal current for 110% overload requirement (at max. 40°C ambient temperature)<br />

I(overload) = maximum 1 min/10 min overload current (high overload)<br />

Vacon NXP 208-240 V, IP21, EMC level T, air-cooled AC drive<br />

The prices are the same as H level ones.<br />

Replace the H by T in the order typecode.<br />

SUBJECT TO CHANGE WITHOUT NOTICE<br />

Vacon Plc Runsorintie 7 65380 VAASA FINLAND tel.:+358-201-2121 fax: +358 (0)201 212 205 http://www.vacon.com 13


Vacon Plc<br />

AC drive<br />

VACON PLC<br />

Vacon NXP 208-240 V (3 phase supply), IP54, EMC level H, air-cooled AC drive<br />

ORDER TYPE CODE MOTOR SHAFT POWER AND CURRENT SIZE/PROT. DIMENSIONS WEIGHT<br />

High overload Low overload FR/IP W x H x D<br />

P [kW] I(H) I(overload) P [kW] I(L) [mm] [kg]<br />

NXP00042A5H1SSSA1A2 0,55 3,7 5,6 0,75 4,8 FR4/IP54 128x292x190 5<br />

NXP00072A5H1SSSA1A2 0,75 4,8 7,2 1,1 6,6 FR4/IP54 128x292x190 5<br />

NXP00082A5H1SSSA1A2 1,1 6,6 9,9 1,5 7,8 FR4/IP54 128x292x190 5<br />

NXP00112A5H1SSSA1A2 1,5 7,8 11,7 2,2 11 FR4/IP54 128x292x190 5<br />

NXP00122A5H1SSSA1A2 2,2 11 16,5 3 12,5 FR4/IP54 128x292x190 5<br />

NXP00172A5H1SSSA1A2 3 12,5 18,8 4 17,5 FR5/IP54 144x391x214 8,1<br />

NXP00252A5H1SSSA1A2 4 17,5 26,3 5,5 25 FR5/IP54 144x391x214 8,1<br />

NXP00312A5H1SSSA1A2 5,5 25 37,5 7,5 31 FR5/IP54 144x391x214 8,1<br />

NXP00482A5H1SSSA1A2 7,5 31 46,5 11 48 FR6/IP54 195x519x237 18,5<br />

NXP00612A5H1SSSA1A2 11 48 72,0 15 61 FR6/IP54 195x519x237 18,5<br />

NXP00752A5H0SSSA1A2 15 61 91,5 18,5 75 FR7/IP54 237x591x257 35<br />

NXP00882A5H0SSSA1A2 18,5 75 112,5 22 88 FR7/IP54 237x591x257 35<br />

NXP01142A5H0SSSA1A2 22 88 132,0 30 114 FR7/IP54 237x591x257 35<br />

NXP01402A5H0SSSA1A2 30 105 158 37 140 FR8/IP54 291x758x344 58<br />

NXP01702A5H0SSSA1A2 37 140 210 45 170 FR8/IP54 291x758x344 58<br />

NXP02052A5H0SSSA1A2 45 170 255 55 205 FR8/IP54 291x758x344 58<br />

NXP02612A5H0SSFA1A2 55 205 308 75 261 FR9/IP54 480x1150x362 146<br />

NXP03002A5H0SSFA1A2 75 245 368 90 300 FR9/IP54 480x1150x362 146<br />

I(H) = nominal current for 150% overload requirement (at max. 50°C ambient temperature)<br />

I(L) = nominal current for 110% overload requirement (at max. 40°C ambient temperature)<br />

I(overload) = maximum 1 min/10 min overload current (high overload)<br />

Vacon NXP 208-240 V, IP54, EMC level T, air-cooled AC drive<br />

The prices are the same as H level ones.<br />

Replace the H by T in the order typecode.<br />

SUBJECT TO CHANGE WITHOUT NOTICE<br />

Vacon Plc Runsorintie 7 65380 VAASA FINLAND tel.:+358-201-2121 fax: +358 (0)201 212 205 http://www.vacon.com 14


Vacon Plc<br />

AC drive<br />

VACON PLC<br />

Vacon NXP 380-500 V, IP21, EMC level H, air-cooled AC drive<br />

ORDER TYPE CODE MOTOR SHAFT POWER AND CURRENT SIZE/PROT. DIMENSIONS WEIGHT<br />

High overload Low overload FR/IP W x H x D<br />

P [kW] I(H) I(overload) P [kW] I(L) [mm] [kg]<br />

NXP00035A2H1SSSA1A2 0,75 2,2 3,3 1,1 3,3 FR4/IP21 128x292x190 5<br />

NXP00045A2H1SSSA1A2 1,1 3,3 5 1,5 4,3 FR4/IP21 128x292x190 5<br />

NXP00055A2H1SSSA1A2 1,5 4,3 6,5 2,2 5,6 FR4/IP21 128x292x190 5<br />

NXP00075A2H1SSSA1A2 2,2 5,6 8,4 3 7,6 FR4/IP21 128x292x190 5<br />

NXP00095A2H1SSSA1A2 3 7,6 11,4 4 9 FR4/IP21 128x292x190 5<br />

NXP00125A2H1SSSA1A2 4 9 13,5 5,5 12 FR4/IP21 128x292x190 5<br />

NXP00165A2H1SSSA1A2 5,5 12 18 7,5 16 FR5/IP21 144x391x214 8,1<br />

NXP00225A2H1SSSA1A2 7,5 16 24 11 23 FR5/IP21 144x391x214 8,1<br />

NXP00315A2H1SSSA1A2 11 23 35 15 31 FR5/IP21 144x391x214 8,1<br />

NXP00385A2H1SSSA1A2 15 31 47 18,5 38 FR6/IP21 195x519x237 18,5<br />

NXP00455A2H1SSSA1A2 18,5 38 57 22 46 FR6/IP21 195x519x237 18,5<br />

NXP00615A2H1SSSA1A2 22 46 69 30 61 FR6/IP21 195x519x237 18,5<br />

NXP00725A2H0SSSA1A2 30 61 92 37 72 FR7/IP21 237x591x257 35<br />

NXP00875A2H0SSSA1A2 37 72 108 45 87 FR7/IP21 237x591x257 35<br />

NXP01055A2H0SSSA1A2 45 87 131 55 105 FR7/IP21 237x591x257 35<br />

NXP01405A2H0SSSA1A2 55 105 158 75 140 FR8/IP21 291x758x344 58<br />

NXP01685A2H0SSSA1A2 75 140 210 90 170 FR8/IP21 291x758x344 58<br />

NXP02055A2H0SSSA1A2 90 170 255 110 205 FR8/IP21 291x758x344 58<br />

NXP02615A2H0SSFA1A2 110 205 308 132 261 FR9/IP21 480x1150x362 146<br />

NXP03005A2H0SSFA1A2 132 245 368 160 300 FR9/IP21 480x1150x362 146<br />

I(H) = nominal current for 150% overload requirement (at max. 50°C ambient temperature)<br />

I(L) = nominal current for 110% overload requirement (at max. 40°C ambient temperature)<br />

I(overload) = maximum 1 min/10 min overload current (high overload)<br />

Vacon NXP 380-500 V, IP21, EMC level T, air-cooled AC drive<br />

The prices are the same as H level ones.<br />

Replace the H by T in the order typecode.<br />

SUBJECT TO CHANGE WITHOUT NOTICE<br />

Vacon Plc Runsorintie 7 65380 VAASA FINLAND tel.:+358-201-2121 fax: +358 (0)201 212 205 http://www.vacon.com 15


Vacon Plc<br />

AC drive<br />

VACON PLC<br />

Vacon NXP 380-500 V, IP54, EMC level H, air-cooled AC drive<br />

ORDER TYPE CODE MOTOR SHAFT POWER AND CURRENT SIZE/PROT. DIMENSIONS WEIGHT<br />

High overload Low overload FR/IP W x H x D<br />

P [kW] I(H) I(overload) P [kW] I(L) [mm] [kg]<br />

NXP00035A5H1SSSA1A2 0,75 2,2 3,3 1,1 3,3 FR4/IP54 128x292x190 5<br />

NXP00045A5H1SSSA1A2 1,1 3,3 5 1,5 4,3 FR4/IP54 128x292x190 5<br />

NXP00055A5H1SSSA1A2 1,5 4,3 6,5 2,2 5,6 FR4/IP54 128x292x190 5<br />

NXP00075A5H1SSSA1A2 2,2 5,6 8,4 3 7,6 FR4/IP54 128x292x190 5<br />

NXP00095A5H1SSSA1A2 3 7,6 11,4 4 9 FR4/IP54 128x292x190 5<br />

NXP00125A5H1SSSA1A2 4 9 13,5 5,5 12 FR4/IP54 128x292x190 5<br />

NXP00165A5H1SSSA1A2 5,5 12 18 7,5 16 FR5/IP54 144x391x214 8,1<br />

NXP00225A5H1SSSA1A2 7,5 16 24 11 23 FR5/IP54 144x391x214 8,1<br />

NXP00315A5H1SSSA1A2 11 23 35 15 31 FR5/IP54 144x391x214 8,1<br />

NXP00385A5H1SSSA1A2 15 31 47 18,5 38 FR6/IP54 195x519x237 18,5<br />

NXP00455A5H1SSSA1A2 18,5 38 57 22 46 FR6/IP54 195x519x237 18,5<br />

NXP00615A5H1SSSA1A2 22 46 69 30 61 FR6/IP54 195x519x237 18,5<br />

NXP00725A5H0SSSA1A2 30 61 92 37 72 FR7/IP54 237x591x257 35<br />

NXP00875A5H0SSSA1A2 37 72 108 45 87 FR7/IP54 237x591x257 35<br />

NXP01055A5H0SSSA1A2 45 87 131 55 105 FR7/IP54 237x591x257 35<br />

NXP01405A5H0SSSA1A2 55 105 158 75 140 FR8/IP54 291x758x344 58<br />

NXP01685A5H0SSSA1A2 75 140 210 90 170 FR8/IP54 291x758x344 58<br />

NXP02055A5H0SSSA1A2 90 170 255 110 205 FR8/IP54 291x758x344 58<br />

NXP02615A5H0SSFA1A2 110 205 308 132 261 FR9/IP54 480x1150x362 146<br />

NXP03005A5H0SSFA1A2 132 245 368 160 300 FR9/IP54 480x1150x362 146<br />

I(H) = nominal current for 150% overload requirement (at max. 50°C ambient temperature)<br />

I(L) = nominal current for 110% overload requirement (at max. 40°C ambient temperature)<br />

I(overload) = maximum 1 min/10 min overload current (high overload)<br />

Vacon NXP 380-500 V, IP54, EMC level T, air-cooled AC drive<br />

The prices are the same as H level ones.<br />

Replace the H by T in the order typecode.<br />

SUBJECT TO CHANGE WITHOUT NOTICE<br />

Vacon Plc Runsorintie 7 65380 VAASA FINLAND tel.:+358-201-2121 fax: +358 (0)201 212 205 http://www.vacon.com 16


Vacon Plc<br />

AC drive<br />

VACON PLC<br />

Vacon NXP 380-500 V, IP00, EMC level N, air-cooled AC drive module, 6-pulse supply<br />

ORDER TYPE CODE MOTOR SHAFT POWER AND CURRENT SIZE/PROT. DIMENSIONS WEIGHT<br />

High overload Low overload FR/IP W x H x D<br />

P [kW] I(H) I(overload) P [kW] I(L) [mm] [kg]<br />

NXP03855A0N0SSAA1A2 160 300 450 200 385 FR10/IP00 500x1165x506 207*<br />

NXP04605A0N0SSAA1A2 200 385 578 250 460 FR10/IP00 500x1165x506 238*<br />

NXP05205A0N0SSAA1A2 250 460 690 250 520 FR10/IP00 500x1165x506 238*<br />

NXP05905A0N0SSAA1A2 250 520 780 315 590 FR11/IP00 709x1206x503 378*<br />

NXP06505A0N0SSAA1A2 315 590 885 355 650 FR11/IP00 709x1206x503 378*<br />

NXP07305A0N0SSAA1A2 355 650 975 400 730 FR11/IP00 709x1206x503 378*<br />

NXP08205A0N0SSAA1A2 400 730 1095 450 820 FR12/IP00 2x(500x1165x506) 414*<br />

NXP09205A0N0SSAA1A2 450 820 1230 500 920 FR12/IP00 2x(500x1165x506) 476*<br />

NXP10305A0N0SSAA1A2 500 920 1380 560 1030 FR12/IP00 2x(500x1165x506) 476*<br />

NXP11505A0N0SSFA1A2 560 1030 1545 630 1150 FR13/IP00 2x(239x1030x372)+(708x1032x553) 700*<br />

NXP13005A0N0SSFA1A2 630 1150 1725 710 1300 FR13/IP00 3x(239x1030x372)+(708x1032x553) 852*<br />

NXP14505A0N0SSFA1A2 710 1300 1950 800 1450 FR13/IP00 3x(239x1030x372)+(708x1032x553) 852*<br />

NXP17705A0N0SSFA1A2 900 1600 2400 1000 1770 FR14/IP00 4x(239x1030x372)+2x(708x1032x553) 995*<br />

NXP21505A0N0SSFA1A2 1100 1940 2910 1200 2150 FR14/IP00 4x(239x1030x372)+2x(708x1032x553) 1010*<br />

*INCLUDES WEIGHT OF INPUT CHOKE<br />

PRICE INCLUDES THE AC CHOKE<br />

INPUT CHOKE DELIVERED AS LOOSE COMPONENT (NOT INCLUDED IN DIMENSIONS)<br />

I(H) = nominal current for 150% overload requirement (at max. 40°C ambient temperature)<br />

I(L) = nominal current for 110% overload requirement (at max. 40°C ambient temperature)<br />

I(overload) = maximum 1 min/10 min overload current (high overload)<br />

Vacon NXP 380-500 V, IP00, EMC level T, air-cooled AC drive module, 6-pulse supply<br />

The prices are the same as N level ones.<br />

Replace the N by T in the order typecode.<br />

SUBJECT TO CHANGE WITHOUT NOTICE<br />

Vacon Plc Runsorintie 7 65380 VAASA FINLAND tel.:+358-201-2121 fax: +358 (0)201 212 205 http://www.vacon.com 17


Vacon Plc<br />

AC drive<br />

VACON PLC<br />

Vacon NXP 380-500 V, IP00, EMC level N, air-cooled AC drive module, 12-pulse supply<br />

ORDER TYPE CODE MOTOR SHAFT POWER AND CURRENT SIZE/PROT. DIMENSIONS WEIGHT<br />

High overload Low overload FR/IP W x H x D<br />

P [kW] I(H) I(overload) P [kW] I(L) [mm] [kg]<br />

NXP03855A0N0TSAA1A2 160 300 450 200 385 FR10/IP00 500x1165x506 207*<br />

NXP04605A0N0TSAA1A2 200 385 578 250 460 FR10/IP00 500x1165x506 238*<br />

NXP05205A0N0TSAA1A2 250 460 690 250 520 FR10/IP00 500x1165x506 238*<br />

NXP05905A0N0TSAA1A2 250 520 780 315 590 FR11/IP00 709x1206x503 378*<br />

NXP06505A0N0TSAA1A2 315 590 885 355 650 FR11/IP00 709x1206x503 378*<br />

NXP07305A0N0TSAA1A2 355 650 975 400 730 FR11/IP00 709x1206x503 378*<br />

NXP08205A0N0TSAA1A2 400 730 1095 450 820 FR12/IP00 2x(500x1165x506) 414*<br />

NXP09205A0N0TSAA1A2 450 820 1230 500 920 FR12/IP00 2x(500x1165x506) 476*<br />

NXP10305A0N0TSAA1A2 500 920 1380 560 1030 FR12/IP00 2x(500x1165x506) 476*<br />

NXP11505A0N0TSFA1A2 560 1030 1545 630 1150 FR13/IP00 2x(239x1030x372)+(708x1032x553) 700*<br />

NXP13005A0N0TSFA1A2 630 1150 1725 710 1300 FR13/IP00 4x(239x1030x372)+(708x1032x553) 852*<br />

NXP14505A0N0TSFA1A2 710 1300 1950 800 1450 FR13/IP00 4x(239x1030x372)+(708x1032x553) 852*<br />

NXP17705A0N0TSFA1A2 900 1600 2400 1000 1770 FR14/IP00 4x(239x1030x372)+2x(708x1032x553) 995*<br />

NXP21505A0N0TSFA1A2 1100 1940 2910 1200 2150 FR14/IP00 4x(239x1030x372)+2x(708x1032x553) 1010*<br />

*INCLUDES WEIGHT OF INPUT CHOKE<br />

PRICE INCLUDES THE AC CHOKE<br />

INPUT CHOKE DELIVERED AS LOOSE COMPONENT (NOT INCLUDED IN DIMENSIONS)<br />

I(H) = nominal current for 150% overload requirement (at max. 40°C ambient temperature)<br />

I(L) = nominal current for 110% overload requirement (at max. 40°C ambient temperature)<br />

I(overload) = maximum 1 min/10 min overload current (high overload)<br />

Vacon NXP 380-500 V, IP00, EMC level T, air-cooled AC drive module, 12-pulse supply<br />

The prices are the same as N level ones.<br />

Replace the N by T in the order typecode.<br />

SUBJECT TO CHANGE WITHOUT NOTICE<br />

Vacon Plc Runsorintie 7 65380 VAASA FINLAND tel.:+358-201-2121 fax: +358 (0)201 212 205 http://www.vacon.com 18


Vacon Plc<br />

AC drive<br />

VACON PLC<br />

Vacon NXP 525-690 V, IP21, EMC level L, air-cooled AC drive<br />

ORDER TYPE CODE MOTOR SHAFT POWER AND CURRENT SIZE/PROT. DIMENSIONS WEIGHT<br />

High overload Low overload FR/IP W x H x D<br />

P [kW] I(H) I(overload) P [kW] I(L) [mm] [kg]<br />

NXP00046A2L0SSSA1A2 2,2 3,2 5,0 3 4,5 FR6/IP21 195x519x237 18,5<br />

NXP00056A2L0SSSA1A2 3 4,5 6,8 4 5,5 FR6/IP21 195x519x237 18,5<br />

NXP00076A2L0SSSA1A2 4 5,5 8,3 5,5 7,5 FR6/IP21 195x519x237 18,5<br />

NXP00106A2L0SSSA1A2 5,5 7,5 11,3 7,5 10 FR6/IP21 195x519x237 18,5<br />

NXP00136A2L0SSSA1A2 7,5 10 15 11 13,5 FR6/IP21 195x519x237 18,5<br />

NXP00186A2L0SSSA1A2 11 13,5 20,3 15 18 FR6/IP21 195x519x237 18,5<br />

NXP00226A2L0SSSA1A2 15 18 27,0 18,5 22 FR6/IP21 195x519x237 18,5<br />

NXP00276A2L0SSSA1A2 18,5 22 33 22 27 FR6/IP21 195x519x237 18,5<br />

NXP00346A2L0SSSA1A2 22 27 41 30 34 FR6/IP21 195x519x237 18,5<br />

NXP00416A2L0SSSA1A2 30 34 51 37 41 FR7/IP21 237x591x257 35<br />

NXP00526A2L0SSSA1A2 37 41 62 45 52 FR7/IP21 237x591x257 35<br />

NXP00626A2L0SSSA1A2 45 52 78 55 62 FR8/IP21 291x758x344 58<br />

NXP00806A2L0SSSA1A2 55 62 93 75 80 FR8/IP21 291x758x344 58<br />

NXP01006A2L0SSSA1A2 75 80 120 90 100 FR8/IP21 291x758x344 58<br />

NXP01256A2L0SSFA1A2 90 100 150 110 125 FR9/IP21 480x1150x362 146<br />

NXP01446A2L0SSFA1A2 110 125 188 132 144 FR9/IP21 480x1150x362 146<br />

NXP01706A2L0SSFA1A2 132 144 216 160 170 FR9/IP21 480x1150x362 146<br />

NXP02086A2L0SSFA1A2 160 170 255 200 208 FR9/IP21 480x1150x362 146<br />

I(H) = nominal current for 150% overload requirement (at max. 50°C ambient temperature)<br />

I(L) = nominal current for 110% overload requirement (at max. 40°C ambient temperature)<br />

I(overload) = maximum 1 min/10 min overload current (high overload)<br />

Vacon NXP 525-690 V, IP21, EMC level T, air-cooled AC drive<br />

The prices are the same as L level ones.<br />

Replace the L by T in the order typecode.<br />

SUBJECT TO CHANGE WITHOUT NOTICE<br />

Vacon Plc Runsorintie 7 65380 VAASA FINLAND tel.:+358-201-2121 fax: +358 (0)201 212 205 http://www.vacon.com 19


Vacon Plc<br />

AC drive<br />

VACON PLC<br />

Vacon NXP 525-690 V, IP54, EMC level L, air-cooled AC drive<br />

ORDER TYPE CODE MOTOR SHAFT POWER AND CURRENT SIZE/PROT. DIMENSIONS WEIGHT<br />

High overload Low overload FR/IP W x H x D<br />

P [kW] I(H) I(overload) P [kW] I(L) [mm] [kg]<br />

NXP00046A5L0SSSA1A2 2,2 3,2 5,0 3 4,5 FR6/IP54 195x519x237 18,5<br />

NXP00056A5L0SSSA1A2 3 4,5 6,8 4 5,5 FR6/IP54 195x519x237 18,5<br />

NXP00076A5L0SSSA1A2 4 5,5 8,3 5,5 7,5 FR6/IP54 195x519x237 18,5<br />

NXP00106A5L0SSSA1A2 5,5 7,5 11,3 7,5 10 FR6/IP54 195x519x237 18,5<br />

NXP00136A5L0SSSA1A2 7,5 10 15 11 13,5 FR6/IP54 195x519x237 18,5<br />

NXP00186A5L0SSSA1A2 11 13,5 20,3 15 18 FR6/IP54 195x519x237 18,5<br />

NXP00226A5L0SSSA1A2 15 18 27,0 18,5 22 FR6/IP54 195x519x237 18,5<br />

NXP00276A5L0SSSA1A2 18,5 22 33 22 27 FR6/IP54 195x519x237 18,5<br />

NXP00346A5L0SSSA1A2 22 27 41 30 34 FR6/IP54 195x519x237 18,5<br />

NXP00416A5L0SSSA1A2 30 34 51 37 41 FR7/IP54 237x591x257 35<br />

NXP00526A5L0SSSA1A2 37 41 62 45 52 FR7/IP54 237x591x257 35<br />

NXP00626A5L0SSSA1A2 45 52 78 55 62 FR8/IP54 291x758x344 58<br />

NXP00806A5L0SSSA1A2 55 62 93 75 80 FR8/IP54 291x758x344 58<br />

NXP01006A5L0SSSA1A2 75 80 120 90 100 FR8/IP54 291x758x344 58<br />

NXP01256A5L0SSFA1A2 90 100 150 110 125 FR9/IP54 480x1150x362 146<br />

NXP01446A5L0SSFA1A2 110 125 188 132 144 FR9/IP54 480x1150x362 146<br />

NXP01706A5L0SSFA1A2 132 144 216 160 170 FR9/IP54 480x1150x362 146<br />

NXP02086A5L0SSFA1A2 160 170 255 200 208 FR9/IP54 480x1150x362 146<br />

I(H) = nominal current for 150% overload requirement (at max. 50°C ambient temperature)<br />

I(L) = nominal current for 110% overload requirement (at max. 40°C ambient temperature)<br />

I(overload) = maximum 1 min/10 min overload current (high overload)<br />

Vacon NXP 525-690 V, IP54, EMC level T, air-cooled AC drive<br />

The prices are the same as L level ones.<br />

Replace the L by T in the order typecode.<br />

SUBJECT TO CHANGE WITHOUT NOTICE<br />

Vacon Plc Runsorintie 7 65380 VAASA FINLAND tel.:+358-201-2121 fax: +358 (0)201 212 205 http://www.vacon.com 20


Vacon Plc<br />

AC drive<br />

VACON PLC<br />

Vacon NXP 525-690 V, IP00, EMC level N, air-cooled AC drive module, 6-pulse supply<br />

ORDER TYPE CODE MOTOR SHAFT POWER AND CURRENT SIZE/PROT. DIMENSIONS WEIGHT<br />

High overload Low overload FR/IP W x H x D<br />

P [kW] I(H) I(overload) P [kW] I(L) [mm] [kg]<br />

NXP02616A0N0SSAA1A2 200 208 312 250 261 FR10/IP00 500x1165x506 176**<br />

NXP03256A0N0SSAA1A2 250 261 392 315 325 FR10/IP00 500x1165x506 207**<br />

NXP03856A0N0SSAA1A2 315 325 488 355 385 FR10/IP00 500x1165x506 207**<br />

NXP04166A0N0SSAA1A2 * 315 325 488 400 416 FR10/IP00 500x1165x506 207**<br />

NXP04606A0N0SSAA1A2 355 385 578 450 460 FR11/IP00 709x1206x503 325**<br />

NXP05026A0N0SSAA1A2 450 460 690 500 502 FR11/IP00 709x1206x503 325**<br />

NXP05906A0N0SSAA1A2 * 500 502 753 560 590 FR11/IP00 709x1206x503 378**<br />

NXP06506A0N0SSAA1A2 560 590 885 630 650 FR12/IP00 2x(500x1165x506) 414**<br />

NXP07506A0N0SSAA1A2 630 650 975 710 750 FR12/IP00 2x(500x1165x506) 414**<br />

NXP08206A0N0SSAA1A2 * 710 750 975 800 820 FR12/IP00 2x(500x1165x506) 414**<br />

NXP09206A0N0SSFA1A2 800 820 1230 900 920 FR13/IP00 2x(239x1030x372)+(708x1032x553) 670**<br />

NXP10306A0N0SSFA1A2 900 920 1380 1000 1030 FR13/IP00 2x(239x1030x372)+(708x1032x553) 670**<br />

NXP11806A0N0SSFA1A2 * 1000 1030 1463 1150 1180 FR13/IP00 2x(239x1030x372)+(708x1032x553) 700**<br />

NXP15006A0N0SSFA1A2 1300 1300 1950 1500 1500 FR14/IP00 3x(239x1030x372)+2x(708x1032x553) 925**<br />

NXP19006A0N0SSFA1A2 1500 1500 2250 1800 1900 FR14/IP00 4x(239x1030x372)+2x(708x1032x553) 995**<br />

NXP22506A0N0SSFA1A2 * 1800 1900 2782 2000 2250 FR14/IP00 4x(239x1030x372)+2x(708x1032x553) 1010**<br />

* max. 35 C ambient temperature<br />

**INCLUDES WEIGHT OF INPUT CHOKE<br />

PRICE INCLUDES THE AC CHOKE<br />

INPUT CHOKE DELIVERED AS LOOSE COMPONENT (NOT INCLUDED IN DIMENSIONS)<br />

I(H) = nominal current for 150% overload requirement (at max. 40°C ambient temperature)<br />

I(L) = nominal current for 110% overload requirement (at max. 40°C ambient temperature)<br />

I(overload) = maximum 1 min/10 min overload current (high overload)<br />

Vacon NXP 525-690 V, IP00, EMC level T, air-cooled AC drive module, 6-pulse supply<br />

The prices are the same as N level ones.<br />

Replace the N by T in the order typecode.<br />

SUBJECT TO CHANGE WITHOUT NOTICE<br />

Vacon Plc Runsorintie 7 65380 VAASA FINLAND tel.:+358-201-2121 fax: +358 (0)201 212 205 http://www.vacon.com 21


Vacon Plc<br />

AC drive<br />

VACON PLC<br />

Vacon NXP 525-690 V, IP00, EMC level N, air-cooled AC drive module, 12-pulse supply<br />

ORDER TYPE CODE MOTOR SHAFT POWER AND CURRENT SIZE/PROT. DIMENSIONS WEIGHT<br />

High overload Low overload FR/IP W x H x D<br />

P [kW] I(H) I(overload) P [kW] I(L) [mm] [kg]<br />

NXP02616A0N0TSAA1A2 200 208 312 250 261 FR10/IP00 500x1165x506 176**<br />

NXP03256A0N0TSAA1A2 250 261 392 315 325 FR10/IP00 500x1165x506 207**<br />

NXP03856A0N0TSAA1A2 315 325 488 355 385 FR10/IP00 500x1165x506 207**<br />

NXP04166A0N0TSAA1A2 * 315 325 488 400 416 FR10/IP00 500x1165x506 207**<br />

NXP04606A0N0TSAA1A2 355 385 578 450 460 FR11/IP00 709x1206x503 325**<br />

NXP05026A0N0TSAA1A2 450 460 690 500 502 FR11/IP00 709x1206x503 325**<br />

NXP05906A0N0TSAA1A2 * 500 502 753 560 590 FR11/IP00 709x1206x503 378**<br />

NXP06506A0N0TSAA1A2 560 590 885 630 650 FR12/IP00 2x(500x1165x506) 414**<br />

NXP07506A0N0TSAA1A2 630 650 975 710 750 FR12/IP00 2x(500x1165x506) 414**<br />

NXP08206A0N0TSAA1A2 * 710 750 975 800 820 FR12/IP00 2x(500x1165x506) 414**<br />

NXP09206A0N0TSFA1A2 800 820 1230 900 920 FR13/IP00 2x(239x1030x372)+(708x1032x553) 670**<br />

NXP10306A0N0TSFA1A2 900 920 1380 1000 1030 FR13/IP00 2x(239x1030x372)+(708x1032x553) 670**<br />

NXP11806A0N0TSFA1A2 * 1000 1030 1463 1150 1180 FR13/IP00 2x(239x1030x372)+(708x1032x553) 700**<br />

NXP15006A0N0TSFA1A2 1300 1300 1950 1500 1500 FR14/IP00 4x(239x1030x372)+2x(708x1032x553) 925**<br />

NXP19006A0N0TSFA1A2 1500 1500 2250 1800 1900 FR14/IP00 4x(239x1030x372)+2x(708x1032x553) 995**<br />

NXP22506A0N0TSFA1A2 * 1800 1900 2782 2000 2250 FR14/IP00 4x(239x1030x372)+2x(708x1032x553) 1010**<br />

* max. 35 C ambient temperature<br />

**INCLUDES WEIGHT OF INPUT CHOKE<br />

PRICE INCLUDES THE AC CHOKE<br />

INPUT CHOKE DELIVERED AS LOOSE COMPONENT (NOT INCLUDED IN DIMENSIONS)<br />

I(H) = nominal current for 150% overload requirement (at max. 40°C ambient temperature)<br />

I(L) = nominal current for 110% overload requirement (at max. 40°C ambient temperature)<br />

I(overload) = maximum 1 min/10 min overload current (high overload)<br />

Vacon NXP 525-690 V, IP00, EMC level T, air-cooled AC drive module, 12-pulse supply<br />

The prices are the same as N level ones.<br />

Replace the N by T in the order typecode.<br />

SUBJECT TO CHANGE WITHOUT NOTICE<br />

Vacon Plc Runsorintie 7 65380 VAASA FINLAND tel.:+358-201-2121 fax: +358 (0)201 212 205 http://www.vacon.com 22


Vacon Plc<br />

AC drive<br />

VACON PLC<br />

Vacon NXP 380-500 V, IP21, EMC level L, air-cooled standalone AC drive<br />

ORDER TYPE CODE MOTOR SHAFT POWER AND CURRENT SIZE/PROT. DIMENSIONS WEIGHT<br />

High overload Low overload FR/IP W x H x D<br />

P [kW] I(H) I(overload) P [kW] I(L) [mm] [kg]<br />

NXP03855A2L0SSAA1A2 160 300 450 200 385 FR10/IP21 595x2018x602 340<br />

NXP04605A2L0SSAA1A2 200 385 578 250 460 FR10/IP21 595x2018x602 340<br />

NXP05205A2L0SSAA1A2 250 460 690 250 520 FR10/IP21 595x2018x602 340<br />

NXP05905A2L0SSAA1A2 250 520 780 315 590 FR11/IP21 794x2018x602 470<br />

NXP06505A2L0SSAA1A2 315 590 885 355 650 FR11/IP21 794x2018x602 470<br />

NXP07305A2L0SSAA1A2 355 650 975 400 730 FR11/IP21 794x2018x602 470<br />

Input fuses are included as standard<br />

I(H) = nominal current for 150% overload requirement (at max. 40°C ambient temperature)<br />

I(L) = nominal current for 110% overload requirement (at max. 40°C ambient temperature)<br />

I(overload) = maximum 1 min/10 min overload current (high overload)<br />

VACON NX_ OPTIONS Integrated load switch for standalone units<br />

ORDER TYPE CODE SUITABILITY DESCRIPTION<br />

NXP_________O__ NXP FR10 standalone Integrated load switch for standalone<br />

NXP_________O__ NXP FR11 standalone Integrated load switch for standalone<br />

Vacon NXP 380-500 V, IP21, EMC level T, air-cooled standalone AC drive<br />

The prices are the same as L level ones.<br />

Replace the L by T in the order typecode.<br />

SUBJECT TO CHANGE WITHOUT NOTICE<br />

Vacon Plc Runsorintie 7 65380 VAASA FINLAND tel.:+358-201-2121 fax: +358 (0)201 212 205 http://www.vacon.com 23


Vacon Plc<br />

AC drive<br />

VACON PLC<br />

Vacon NXP 380-500 V, IP54, EMC level L, air-cooled standalone AC drive<br />

ORDER TYPE CODE MOTOR SHAFT POWER AND CURRENT SIZE/PROT. DIMENSIONS WEIGHT<br />

High overload Low overload FR/IP W x H x D<br />

P [kW] I(H) I(overload) P [kW] I(L) [mm] [kg]<br />

NXP03855A5L0SSAA1A2 160 300 450 200 385 FR10/IP54 595x2018x602 340<br />

NXP04605A5L0SSAA1A2 200 385 578 250 460 FR10/IP54 595x2018x602 340<br />

NXP05205A5L0SSAA1A2 250 460 690 250 520 FR10/IP54 595x2018x602 340<br />

Input fuses are included as standard<br />

I(H) = nominal current for 150% overload requirement (at max. 40°C ambient temperature)<br />

I(L) = nominal current for 110% overload requirement (at max. 40°C ambient temperature)<br />

I(overload) = maximum 1 min/10 min overload current (high overload)<br />

VACON NX_ OPTIONS Integrated load switch for standalone units<br />

ORDER TYPE CODE SUITABILITY DESCRIPTION<br />

NXP_________O__ NXP FR10 standalone Integrated load switch for standalone<br />

Vacon NXP 380-500 V, IP54, EMC level T, air-cooled standalone AC drive<br />

The prices are the same as L level ones.<br />

Replace the L by T in the order typecode.<br />

SUBJECT TO CHANGE WITHOUT NOTICE<br />

Vacon Plc Runsorintie 7 65380 VAASA FINLAND tel.:+358-201-2121 fax: +358 (0)201 212 205 http://www.vacon.com 24


Vacon Plc<br />

AC drive<br />

VACON PLC<br />

Vacon NXP 525-690 V, IP21, EMC level L, air-cooled standalone AC drive<br />

ORDER TYPE CODE MOTOR SHAFT POWER AND CURRENT SIZE/PROT. DIMENSIONS WEIGHT<br />

High overload Low overload FR/IP W x H x D<br />

P [kW] I(H) I(overload) P [kW] I(L) [mm] [kg]<br />

NXP02616A2L0SSAA1A2 200 208 312 250 261 FR10/IP21 595x2020x602 340<br />

NXP03256A2L0SSAA1A2 250 261 392 315 325 FR10/IP21 595x2020x602 340<br />

NXP03856A2L0SSAA1A2 315 325 488 355 385 FR10/IP21 595x2020x602 340<br />

NXP04166A2L0SSAA1A2 315 325 488 400 416 FR10/IP21 595x2020x602 340<br />

NXP04606A2L0SSAA1A2 355 385 578 450 460 FR11/IP21 794x2018x602 400<br />

NXP05026A2L0SSAA1A2 450 460 690 500 502 FR11/IP21 794x2018x602 400<br />

NXP05906A2L0SSAA1A2 500 502 753 560 590 FR11/IP21 794x2018x602 470<br />

Input fuses are included as standard<br />

I(H) = nominal current for 150% overload requirement (at max. 40°C ambient temperature)<br />

I(L) = nominal current for 110% overload requirement (at max. 40°C ambient temperature)<br />

I(overload) = maximum 1 min/10 min overload current (high overload)<br />

VACON NX_ OPTIONS Integrated load switch for standalone units<br />

ORDER TYPE CODE SUITABILITY DESCRIPTION<br />

NXP_________O__ FR10 standalone Integrated load switch for standalone<br />

NXP_________O__ FR11 standalone Integrated load switch for standalone<br />

Vacon NXP 525-690 V, IP21, EMC level T, air-cooled standalone AC drive<br />

The prices are the same as L level ones.<br />

Replace the L by T in the order typecode.<br />

SUBJECT TO CHANGE WITHOUT NOTICE<br />

Vacon Plc Runsorintie 7 65380 VAASA FINLAND tel.:+358-201-2121 fax: +358 (0)201 212 205 http://www.vacon.com 25


Vacon Plc<br />

AC drive<br />

VACON PLC<br />

Vacon NXP 525-690 V, IP54, EMC level L, air-cooled standalone AC drive<br />

ORDER TYPE CODE MOTOR SHAFT POWER AND CURRENT SIZE/PROT. DIMENSIONS WEIGHT<br />

High overload Low overload FR/IP W x H x D<br />

P [kW] I(H) I(overload) P [kW] I(L) [mm] [kg]<br />

NXP02616A5L0SSAA1A2 200 208 312 250 261 FR10/IP54 595x2020x602 340<br />

NXP03256A5L0SSAA1A2 250 261 392 315 325 FR10/IP54 595x2020x602 340<br />

NXP03856A5L0SSAA1A2 315 325 488 355 385 FR10/IP54 595x2020x602 340<br />

NXP04166A5L0SSAA1A2 315 325 488 400 416 FR10/IP54 595x2020x602 340<br />

Input fuses are included as standard<br />

I(H) = nominal current for 150% overload requirement (at max. 40°C ambient temperature)<br />

I(L) = nominal current for 110% overload requirement (at max. 40°C ambient temperature)<br />

I(overload) = maximum 1 min/10 min overload current (high overload)<br />

VACON NX_ OPTIONS Integrated load switch for standalone units<br />

ORDER TYPE CODE SUITABILITY DESCRIPTION<br />

NXP_________O__ FR10 standalone Integrated load switch for standalone<br />

Vacon NXP 525-690 V, IP54, EMC level T, air-cooled standalone AC drive<br />

The prices are the same as L level ones.<br />

Replace the L by T in the order typecode.<br />

SUBJECT TO CHANGE WITHOUT NOTICE<br />

Vacon Plc Runsorintie 7 65380 VAASA FINLAND tel.:+358-201-2121 fax: +358 (0)201 212 205 http://www.vacon.com 26


Vacon Plc<br />

AC drive<br />

VACON PLC<br />

Vacon NX_ OPTIONS Internal brake choppers<br />

ORDER TYPE CODE SUITABILITY DESCRIPTION<br />

208-240 V<br />

NX_00752___1___ FR7 Factory option *<br />

NX_00882___1___ FR7 Factory option *<br />

NX_01142___1___ FR7 Factory option *<br />

NX_01402___1___ FR8 Factory option, includes the connection box */**<br />

NX_01702___1___ FR8 Factory option, includes the connection box */**<br />

NX_02052___1___ FR8 Factory option, includes the connection box */**<br />

380-500 V<br />

NX_00725___1___ FR7 Factory option *<br />

NX_00875___1___ FR7 Factory option *<br />

NX_01055___1___ FR7 Factory option *<br />

NX_01405___1___ FR8 Factory option, includes the connection box */**<br />

NX_01685___1___ FR8 Factory option, includes the connection box */**<br />

NX_02055___1___ FR8 Factory option, includes the connection box */**<br />

NX_02615___1___ FR9 Factory option, includes the connection box */**<br />

NX_03005___1___ FR9 Factory option, includes the connection box */**<br />

NX_03855___1___ FR10 Factory option *<br />

NX_04605___1___ FR10 Factory option *<br />

NX_05205___1___ FR10 Factory option *<br />

NX_05905___1___ FR11 Factory option *<br />

NX_06505___1___ FR11 Factory option *<br />

NX_07305___1___ FR11 Factory option *<br />

NX_08205___1___ FR12 Factory option *<br />

NX_09205___1___ FR12 Factory option *<br />

NX_10305___1___ FR12 Factory option *<br />

525-690 V<br />

NX_00046___1___ FR6 Factory option *<br />

NX_00056___1___ FR6 Factory option *<br />

NX_00076___1___ FR6 Factory option *<br />

NX_00106___1___ FR6 Factory option *<br />

NX_00136___1___ FR6 Factory option *<br />

NX_00186___1___ FR6 Factory option *<br />

NX_00226___1___ FR6 Factory option *<br />

NX_00276___1___ FR6 Factory option *<br />

NX_00346___1___ FR6 Factory option *<br />

NX_00416___1___ FR7 Factory option *<br />

NX_00526___1___ FR7 Factory option *<br />

NX_00626___1___ FR8 Factory option, includes the connection box */**<br />

NX_00806___1___ FR8 Factory option, includes the connection box */**<br />

NX_01006___1___ FR8 Factory option, includes the connection box */**<br />

NX_01256___1___ FR9 Factory option, includes the connection box */**<br />

NX_01446___1___ FR9 Factory option, includes the connection box */**<br />

NX_01706___1___ FR9 Factory option, includes the connection box */**<br />

NX_02086___1___ FR9 Factory option, includes the connection box */**<br />

NX_02616___1___ FR10 Factory option *<br />

NX_03256___1___ FR10 Factory option *<br />

NX_03856___1___ FR10 Factory option *<br />

NX_04166___1___ FR10 Factory option *<br />

NX_04606___1___ FR11 Factory option *<br />

NX_05026___1___ FR11 Factory option *<br />

NX_05906___1___ FR11 Factory option *<br />

NX_06506___1___ FR12 Factory option *<br />

NX_07506___1___ FR12 Factory option *<br />

NX_08206___1___ FR12 Factory option *<br />

*The factory option can be ordered only as a part of the AC drive, they can not be ordered separately<br />

**Increases the total height of the AC drive by 203 mm<br />

Pay also attention to the additional space required for the cables<br />

In NXC the option +MDC is obligatory with brake choppers (in order to get the terminals lower for easy installation of the cables)<br />

SUBJECT TO CHANGE WITHOUT NOTICE<br />

Vacon Plc Runsorintie 7 65380 VAASA FINLAND tel.:+358-201-2121 fax: +358 (0)201 212 205 http://www.vacon.com 27


Vacon Plc<br />

AC drive<br />

VACON PLC<br />

Vacon NX_ OPTIONS DC-connection (FR8-FR11)<br />

ORDER TYPE CODE SUITABILITY DESCRIPTION<br />

208-240 V<br />

NX_01402____B__ FR8 Factory option, includes the connection box */**<br />

NX_01702____B__ FR8 Factory option, includes the connection box */**<br />

NX_02052____B__ FR8 Factory option, includes the connection box */**<br />

NX_02612____B__ FR9 Factory option, includes the connection box */**<br />

NX_03002____B__ FR9 Factory option, includes the connection box */**<br />

380-500 V<br />

NX_01405____B__ FR8 Factory option, includes the connection box */**<br />

NX_01685____B__ FR8 Factory option, includes the connection box */**<br />

NX_02055____B__ FR8 Factory option, includes the connection box */**<br />

NX_02615____B__ FR9 Factory option, includes the connection box */**<br />

NX_03005____B__ FR9 Factory option, includes the connection box */**<br />

NX_03855____B__ FR10 Factory option *<br />

NX_04605____B__ FR10 Factory option *<br />

NX_05205____B__ FR10 Factory option *<br />

NX_05905____B__ FR11 Factory option *<br />

NX_06505____B__ FR11 Factory option *<br />

NX_07305____B__ FR11 Factory option *<br />

525-690 V<br />

NX_00626____B__ FR8 Factory option, includes the connection box */**<br />

NX_00806____B__ FR8 Factory option, includes the connection box */**<br />

NX_01006____B__ FR8 Factory option, includes the connection box */**<br />

NX_01256____B__ FR9 Factory option, includes the connection box */**<br />

NX_01446____B__ FR9 Factory option, includes the connection box */**<br />

NX_01706____B__ FR9 Factory option, includes the connection box */**<br />

NX_02086____B__ FR9 Factory option, includes the connection box */**<br />

NX_02616____B__ FR10 Factory option *<br />

NX_03256____B__ FR10 Factory option *<br />

NX_03856____B__ FR10 Factory option *<br />

NX_04166____B__ FR11 Factory option *<br />

NX_04606____B__ FR11 Factory option *<br />

NX_05026____B__ FR11 Factory option *<br />

NX_05906____B__ FR11 Factory option *<br />

*The factory option can be ordered only as a part of the AC drive, they can not be ordered separately<br />

**Increases the total height of the AC drive by 203 mm<br />

Pay also attention to the additional space required for the cables<br />

Vacon NX_ OPTIONS Internal brake resistors<br />

ORDER TYPE CODE SUITABILITY Resistance Energy 2 s full Avarage power<br />

[Ω] torque braking 1 pulse/min<br />

[kJ] [W]<br />

NX_00035___2___ FR4 120 4 45<br />

NX_00045___2___ FR4 120 4 45<br />

NX_00055___2___ FR4 120 4 45<br />

NX_00075___2___ FR4 120 4 45<br />

NX_00095___2___ FR4 120 4 45<br />

NX_00125___2___ FR4 120 4 45<br />

NX_00165___2___ FR5 55 8,9 100<br />

NX_00225___2___ FR5 55 8,9 100<br />

NX_00315___2___ FR5 55 8,9 100<br />

NX_00385___2___ FR6 30 16 175<br />

NX_00455___2___ FR6 30 16 175<br />

NX_00615___2___ FR6 30 16 175<br />

The resistors are designed for 2 s full torque braking from nominal motor speed to zero or 1 s full power braking every minute<br />

Please see more information from Brake resistor's manual (please download from www.vacon.com)<br />

SUBJECT TO CHANGE WITHOUT NOTICE<br />

Vacon Plc Runsorintie 7 65380 VAASA FINLAND tel.:+358-201-2121 fax: +358 (0)201 212 205 http://www.vacon.com 28


Vacon Plc<br />

AC drive<br />

VACON PLC<br />

Vacon NX_ OPTIONS External brake resistors<br />

ORDER TYPE CODE SUITABILITY Continuous Power [kW] Resistance WEIGHT DIMENSIONS<br />

[Ω] [KG] W x H x D<br />

208-240 V [mm]<br />

BRR-0025-LD-2 NX_00032-NX_00252 Brake resistor 0,3 kW 30 0,39 60x31x165<br />

BRR-0031-LD-2 NX_00312 Brake resistor 0,4 kW 20 0,88 60x31x246<br />

BRR-0061-LD-2 NX_00482-NX_00612 Brake resistor 0,8 kW 10 1,45 60x31x386<br />

BRR-0114-LD-2 NX_00752-NX_01142 Brake resistor 2,5 kW 3,3 3,3 124x117x426<br />

BRR-0205-LD-2 NX_01402-NX_03002 Brake resistor 5,8 kW 1,4 11 260x101x745<br />

BRR-0025-HD-2 NX_00032-NX_00252 Brake resistor 0,1 kW 30 2 60x106x381<br />

BRR-0031-HD-2 * NX_00312 Brake resistor 0,2 kW 20 2,4 124x122x400<br />

BRR-0061-HD-2 * NX_00482-NX_00612 Brake resistor 0,3 kW 10 4,6 124x122x700<br />

BRR-0114-HD-2 * NX_00752-NX_01142 Brake resistor 1 kW 3,3 12,8 260x101x860<br />

BRR-0205-HD-2 * NX_01402-NX_03002 Brake resistor 2,2 kW 1,4 29 260x263x960<br />

Transfer products<br />

380-500 V<br />

BRR-0022-LD-5 NX_00035-NX_00225 Brake resistor 0,6 kW 63 1,2 60x31x335<br />

BRR-0031-LD-5 NX_00315 Brake resistor 0,9 kW 42 1,8 117x124x225<br />

BRR-0045-LD-5 NX_00385-NX_00455 Brake resistor 1,8 kW 21 3,3 117x124x426<br />

BRR-0061-LD-5 NX_00615 Brake resistor 1,1 kW 21 4 117x124x526<br />

BRR-0105-LD-5 NX_00725-NX_01055 Brake resistor 2,3 kW 6,5 12,8 260x101x860<br />

BRR-0300-LD-5 * NX_01405-NX_03005 Brake resistor 4,6 kW 3,25 29 260x263x960<br />

BRR-0520-LD-5 * NX_03855-NX_05205 Brake resistor 12 kW 1,4 30 480x600x740<br />

BRR-0730-LD-5 * NX_05905-NX_07305 Brake resistor 19 kW 0,9 35 480x600x740<br />

BRR-0022-HD-5 * NX_00035-NX_00225 Brake resistor 0,2 kW 63 3,5 124x126x540<br />

BRR-0031-HD-5 * NX_00315 Brake resistor 0,4 kW 42 4,6 124x126x700<br />

BRR-0045-HD-5 * NX_00385-NX_00455 Brake resistor 0,7 kW 21 11,3 260x101x700<br />

BRR-0061-HD-5 * NX_00615 Brake resistor 1,1 kW 14 12,8 260x101x860<br />

BRR-0105-HD-5 * NX_00725-NX_01055 Brake resistor 2,3 kW 6,5 25 480x300x530<br />

BRR-0300-HD-5 * NX_01405-NX_03005 Brake resistor 4,6 kW 3,25 79 480x300x740<br />

BRR-0520-HD-5 * NX_03855-NX_05205 Brake resistor 7 kW 1,4 153 480x1020x740<br />

BRR-0730-HD-5 * NX_05905-NX_07305 Brake resistor 13 kW 0,9 223 480x1320x740<br />

for NX_08205-NX_10305 (FR12) please use 2xBRR0520LD5 or 2xBRR0520HD5<br />

Transfer products<br />

525-690 V SUITABILITY<br />

BRR-0013-LD-6 NX_00036-NX_00136 Brake resistor 3,2 kW 100 1,45 60x31x405<br />

BRR-0034-LD-6 NX_00186-NX_00346 Brake resistor 5,0 kW 30 3,3 117x124x426<br />

BRR-0052-LD-6 NX_00416-NX_00526 Brake resistor 1,5kW 18 5,6 117x124x725<br />

BRR-0100-LD-6 * NX_00626-NX_01006 Brake resistor 3,3kW 9 14,6 260x101x960<br />

BRR-0208-LD-6 * NX_01446-NX_02086 Brake resistor 4kW 7 29 260x263x860<br />

BRR-0416-LD-6 * NX_02166-NX_04166 Brake resistor 13 kW 2,5 53 480x300x740<br />

BRR-0590-LD-6 * NX_04606-NX_05906 Brake resistor 19 kW 1,7 79 480x300x740<br />

BRR-0013-HD-6 * NX_00036-NX_00136 Brake resistor 0,7 kW 100 3,9 124x126x600<br />

BRR-0034-HD-6 * NX_00186-NX_00346 Brake resistor 2,5kW 30 13 260x101x800<br />

BRR-0052-HD-6 * NX_00416-NX_00526 Brake resistor 4kW 18 29 260x263x900<br />

BRR-0100-HD-6 * NX_00626-NX_01006 Brake resistor 9 kW 9 43,4 480x300x740<br />

BRR-0208-HD-6 * NX_01446-NX_02086 Brake resistor 12 kW 7 51 480x300x740<br />

BRR-0416-HD-6 * NX_02166-NX_04166 Brake resistor 34 kW 2,5 153 480x1020x740<br />

BRR-0590-HD-6 * NX_04606-NX_05906 Brake resistor 50 kW 1,7 223 480x1320x740<br />

for NX_06506-NX_08206 (FR12) please use 2xBRR0416LD6 or 2xBRR0416HD6<br />

Transfer products<br />

*Thermal protection switch included<br />

LD = LIGHT DUTY: 5 s NOMINAL TORQUE BRAKING FROM NOMINAL SPEED REDUCED LINEARLY TO ZERO ONCE PER 120 s<br />

HD = HEAVY DUTY: 3 s NOMINAL TORQUE BRAKING AT NOMINAL SPEED + 7 s NOMINAL TORQUE BRAKING FROM NOMINAL<br />

SPEED REDUCED LINEARLY TO ZERO ONCE PER 120 s<br />

Vacon NX_ OPTIONS Overtemperature sensors<br />

ORDER TYPE CODE<br />

SUITABILITY<br />

OT-1<br />

OT-2<br />

BRR-0025-LD-2 - BRR-0061-LD-2, BRR-0022-LD-5, BRR-0013-LD-6<br />

BRR-0144-LD-2 - BRR-0205-LD-2, BRR-0031-LD-5 - BRR-0300-LD-5, BRR-0034-LD-6 - BRR-0208-LD-6<br />

Transfer products<br />

SUBJECT TO CHANGE WITHOUT NOTICE<br />

Vacon Plc Runsorintie 7 65380 VAASA FINLAND tel.:+358-201-2121 fax: +358 (0)201 212 205 http://www.vacon.com 29


Vacon Plc<br />

AC drive<br />

VACON PLC<br />

VACON NX_OPTIONS External du/dt filters 380-690 V<br />

ORDER TYPE CODE SUITABILITY IP class NOTE DIMENSIONS WEIGHT In [A] In [A]<br />

W x H x D [kg] Ta 40°C Ta 50°C<br />

[mm]<br />

DUT-0012-6-0-P NX_* IP00 Maximum switching frequency 3,6 kHz 155x190x110 3 12 11<br />

DUT-0025-6-0-P NX_* IP00 Maximum switching frequency 3,6 kHz 155x220x130 6 25 22<br />

DUT-0055-6-0-P NX_* IP00 Maximum switching frequency 3,6 kHz 190x250x130 10 55 48<br />

DUT-0080-6-0-P NX_* IP00 Maximum switching frequency 3,6 kHz 210x280x135 13 80 70<br />

DUT-0130-6-0-P NX_* IP00 Maximum switching frequency 3,6 kHz 240x300x160 22 130 115<br />

DUT-0210-6-0-P NX_* IP00 Maximum switching frequency 3,6 kHz 240x320x185 31 210 185<br />

DUT-0280-6-0-P NX_* IP00 Maximum switching frequency 3,6 kHz 300x299x235 45 280 245<br />

DUT-0350-6-0-P NX_* IP00 Maximum switching frequency 3,6 kHz 300x299x250 50 350 310<br />

DUT-0420-6-0-P NX_* IP00 Maximum switching frequency 3,6 kHz 300x220x349 52 420 370<br />

DUT-0600-6-0-P NX_* IP00 Maximum switching frequency 3,6 kHz 300x449x230 76 600 530<br />

DUT-0820-6-0-P NX_* IP00 Maximum switching frequency 3,6 kHz 300x499x255 92 820 720<br />

DUT-1200-6-0-P NX_* IP00 Maximum switching frequency 3,6 kHz 420x500x310 160 1200 1055<br />

DUT-1500-6-0-P NX_* IP00 Maximum switching frequency 3,6 kHz 480x599x340 200 1500 1320<br />

DUT-0012-6-2-P NX_* IP21 Maximum switching frequency 3,6 kHz 195x145x265 8,6 12 10,5<br />

DUT-0034-6-2-P NX_* IP21 Maximum switching frequency 3,6 kHz 195x145x265 8,6 34 30<br />

DUT-0055-6-2-P NX_* IP21 Maximum switching frequency 3,6 kHz 237x170x330 13 55 48<br />

DUT-0100-6-2-P NX_* IP21 Maximum switching frequency 3,6 kHz 289x170x430 23 100 88<br />

DUT-0210-6-2-P NX_* IP21 Maximum switching frequency 3,6 kHz 480x225x540 42 210 180<br />

DUT-0012-6-5-P NX_* IP54 Maximum switching frequency 3,6 kHz 150x135x210 7 12 10,5<br />

DUT-0034-6-5-P NX_* IP54 Maximum switching frequency 3,6 kHz 200x135x260 11 34 30<br />

DUT-0055-6-5-P NX_* IP54 Maximum switching frequency 3,6 kHz 300x215x360 25 55 48<br />

DUT-0100-6-5-P NX_* IP54 Maximum switching frequency 3,6 kHz 300x215x360 35 100 88<br />

Transfer products<br />

*When ordering NXC please choose +ODU; the filters are also suitable for 380-500 V supply voltage<br />

Typecode e. g. DUT-0025-6-0-P=DUT-25A-690 V-IP00-manufacturer's identification<br />

Vacon NX_OPTIONS External sine wave filters 380-500 V and 525-690 V<br />

ORDER TYPE CODE SUITABILITY IP class NOTE DIMENSIONS WEIGHT [kg] In [A] In [A]<br />

W x H x D Ta 40°C Ta 50°C<br />

[mm]<br />

SIN-0010-5-0-P NX_ * IP00 Minimum switching frequency 3,6 kHz 190x215x145 10 10 8,8<br />

SIN-0018-5-0-P NX_ * IP00 Minimum switching frequency 3,6 kHz 210x240x154 12,5 18 16<br />

SIN-0032-5-0-P NX_ * IP00 Minimum switching frequency 3,6 kHz 240x270x180 19 32 28<br />

SIN-0048-5-0-P NX_ * IP00 Minimum switching frequency 3,6 kHz 240x270x200 24 48 42<br />

SIN-0075-5-0-P NX_ * IP00 Minimum switching frequency 3,6 kHz 300x330x230 48 75 66<br />

SIN-0110-5-0-P NX_ * IP00 Minimum switching frequency 3,6 kHz 360x460x290 73 110 97<br />

SIN-0180-5-0-P NX_ * IP00 Minimum switching frequency 3,6 kHz 360x460x330 90 180 155<br />

SIN-0270-5-0-P NX_ * IP00 Minimum switching frequency 3,6 kHz 360x500x350 122 270 235<br />

SIN-0410-5-0-P NX_ * IP00 Minimum switching frequency 3,6 kHz 420x525x380 190 410 360<br />

SIN-0600-5-0-P NX_ * IP00 Minimum switching frequency 3,6 kHz 514x500x490 220 600 525<br />

SIN-0840-5-0-P NX_ * IP00 Minimum switching frequency 3,6 kHz 480x595x520 300 840 740<br />

SIN-1160-5-0-P NX_ * IP00 Minimum switching frequency 3,6 kHz 660x710x550 420 1160 1020<br />

SIN-1480-5-0-P NX_ * IP00 Minimum switching frequency 3,6 kHz 660x750x580 500 1480 1302<br />

SIN-0005-6-0-P NXS, NXP, NXC * IP00 Minimum switching frequency 1,5 kHz 155x180x145 4,5 4,5 4<br />

SIN-0008-6-0-P NXS, NXP, NXC * IP00 Minimum switching frequency 1,5 kHz 155x180x145 6,8 7,5 6,6<br />

SIN-0014-6-0-P NXS, NXP, NXC * IP00 Minimum switching frequency 1,5 kHz 190x215x150 10 14 12<br />

SIN-0023-6-0-P NXS, NXP, NXC * IP00 Minimum switching frequency 1,5 kHz 240x260x180 17 23 20<br />

SIN-0035-6-0-P NXS, NXP, NXC * IP00 Minimum switching frequency 1,5 kHz 240x265x230 26 35 31<br />

SIN-0052-6-0-P NXS, NXP, NXC * IP00 Minimum switching frequency 1,5 kHz 300x320x255 36 52 115<br />

SIN-0085-6-0-P NXS, NXP, NXC * IP00 Minimum switching frequency 1,5 kHz 365x460x300 68 85 75<br />

SIN-0122-6-0-P NXS, NXP, NXC * IP00 Minimum switching frequency 1,5 kHz 365x475x300 78 122 107<br />

SIN-0185-6-0-P NXS, NXP, NXC * IP00 Minimum switching frequency 1,5 kHz 365x475x335 110 185 160<br />

SIN-0287-6-0-P NXS, NXP, NXC * IP00 Minimum switching frequency 1,5 kHz 480x525x360 195 287 250<br />

SIN-0390-6-0-P NXS, NXP, NXC * IP00 Minimum switching frequency 1,5 kHz 480x525x410 270 390 340<br />

SIN-0460-6-0-P NXS, NXP, NXC * IP00 Minimum switching frequency 1,5 kHz 530x600x420 340 460 400<br />

SIN-0620-6-0-P NXS, NXP, NXC * IP00 Minimum switching frequency 1,5 kHz 530x625x540 370 620 545<br />

SIN-0780-6-0-P NXS, NXP, NXC * IP00 Minimum switching frequency 1,5 kHz 480x775x500 470 780 680<br />

SIN-0920-6-0-P NXS, NXP, NXC * IP00 Minimum switching frequency 1,5 kHz 660x775x550 470 920 810<br />

SIN-1180-6-0-P NXS, NXP, NXC * IP00 Minimum switching frequency 1,5 kHz 660x700x600 660 1180 1040<br />

SIN-0004-5-5-P NXS, NXP, NXC * IP54 Minimum switching frequency 3,6 kHz 200x135x260 9,5 4,3 3,8<br />

SIN-0008-5-5-P NXS, NXP, NXC * IP54 Minimum switching frequency 3,6 kHz 200x135x260 11,2 7,6 6,7<br />

SIN-0012-5-5-P NXS, NXP, NXC * IP54 Minimum switching frequency 3,6 kHz 300x215x360 23,2 12 10,5<br />

SIN-0016-5-5-P NXS, NXP, NXC * IP54 Minimum switching frequency 3,6 kHz 300x215x360 28,7 16 14<br />

SIN-0023-5-5-P NXS, NXP, NXC * IP54 Minimum switching frequency 3,6 kHz 300x215x360 34,2 23 20<br />

SIN-0032-5-5-P NXS, NXP, NXC * IP54 Minimum switching frequency 3,6 kHz 300x215x360 37 32 28<br />

SIN-0038-5-5-P NXS, NXP, NXC * IP54 Minimum switching frequency 3,6 kHz 610x500x500 60 38 33<br />

SIN-0046-5-5-P NXS, NXP, NXC * IP54 Minimum switching frequency 3,6 kHz 610x500x500 75 46 40<br />

SIN-0055-5-5-P NXS, NXP, NXC * IP54 Minimum switching frequency 3,6 kHz 670x560x560 95 55 48<br />

SIN-0061-5-5-P NXS, NXP, NXC * IP54 Minimum switching frequency 3,6 kHz 670x560x560 100 61 53<br />

SIN-0072-5-5-P NXS, NXP, NXC * IP54 Minimum switching frequency 3,6 kHz 670x560x560 110 72 63<br />

Transfer products<br />

*When ordering NXC please choose +OSI<br />

Typecode e. g. SIN-0010-5-0=SIN-10 A-500 V-IP00<br />

SUBJECT TO CHANGE WITHOUT NOTICE<br />

Vacon Plc Runsorintie 7 65380 VAASA FINLAND tel.:+358-201-2121 fax: +358 (0)201 212 205 http://www.vacon.com 30


Vacon Plc<br />

AC drive<br />

VACON PLC<br />

Vacon NX_ OPTIONS External filters for NXL<br />

ORDER TYPE CODE SUITABILITY DESCRIPTION DIMENSIONS<br />

W x H x D<br />

[mm]<br />

RFI-0008-5-1 MF2-MF3/380-500 V RFI filter, H level, IP20, footprint 60x252x35<br />

RFI-0013-2-1 MF2-MF3/208-240 V RFI filter, H level, IP20, footprint, 1~ SUPPLY 60x252x35<br />

RFI-0012-2-1 MF2-MF3/208-240 V RFI filter, H level, IP20, 1~SUPPLY * 58x115x46<br />

LRF-0003-5-1 MF2/380-500 V THD+RFI filter, H level, IP20, footprint 60x252x35<br />

LRF-0005-2-1 NXL00022, NXL00032 THD+RFI filter, H level, IP20, 1~ SUPPLY 70x200x125<br />

*Conducted emissions, moter cable max. 5 m: EMC C level<br />

Transfer products<br />

Vacon NX_ OPTIONS External RFI filters<br />

ORDER TYPE CODE SUITABILITY DESCRIPTION DIMENSIONS<br />

W x H x D<br />

[mm]<br />

RFI-0012-5-5 FR4, MF4 / 380-500 V C level, IP54, footprint 125x390x65<br />

RFI-0031-5-5 FR5, MF5 / 380-500 V C level, IP54, footprint 135x490x65<br />

RFI-0061-5-5 FR6, MF6 / 380-500 V C level, IP54, footprint 185x620x75<br />

Transfer products<br />

VACON NX_OPTIONS External RFI filters for NX<br />

ORDER TYPE CODE SUITABILITY DESCRIPTION DIMENSIONS<br />

W x H x D<br />

500V: [mm]<br />

RFI-0150-5-0 NXS, NXP C level, IP00 300x120x160<br />

RFI-0130-5-0 NXS, NXP C level, IP00 439x240x110<br />

RFI-0250-5-0 NXS, NXP C level, IP00 300x125x180<br />

RFI-0320-5-0 NXS, NXP C level, IP00 300x115x210<br />

RFI-0400-5-0 NXS, NXP C level, IP00 300x115x210<br />

RFI-0600-5-0 NXS, NXP C level, IP00 300x135x210<br />

RFI-1000-5-0 NXS, NXP C level, IP00 350x170x230<br />

RFI-1600-5-0 NXS, NXP C level, IP00 400x160x250<br />

RFI-2500-5-0 NXS, NXP C level, IP00 600x200x300<br />

690 V:<br />

RFI-0042-6-0 NXS, NXP C level, IP00 329x185x70<br />

RFI-0100-6-0 NXS, NXP C level, IP00 379x220x90<br />

RFI-0180-6-0 NXS, NXP C level, IP00 300x120x160<br />

RFI-0300-6-0 NXS, NXP C level, IP00 300x115x210<br />

RFI-0400-6-0 NXS, NXP C level, IP00 300x115x210<br />

RFI-0600-6-0 NXS, NXP C level, IP00 300x135x210<br />

RFI-0900-6-0 NXS, NXP C level, IP00 350x170x230<br />

Transfer products<br />

VACON NX_OPTIONS Integrated RFI filter options<br />

ORDER TYPE CODE SUITABILITY DESCRIPTION<br />

NX_00035__C____ NX_* ** Factory option<br />

NX_00045__C____ NX_* ** Factory option<br />

NX_00055__C____ NX_* ** Factory option<br />

NX_00075__C____ NX_* ** Factory option<br />

NX_00095__C____ NX_* ** Factory option<br />

NX_00125__C____ NX_* ** Factory option<br />

NX_00165__C____ NX_* ** Factory option<br />

NX_00225__C____ NX_* ** Factory option<br />

NX_00315__C____ NX_* ** Factory option<br />

NX_00385__C____ NX_* ** Factory option<br />

NX_00455__C____ NX_* ** Factory option<br />

NX_00615__C____ NX_* ** Factory option<br />

*NXS/NXP IP21: CONDUCTED EMISSIONS: C level, RADIATED EMISSIONS: H level<br />

*NXS/NXP IP54: CONDUCTED EMISSIONS: C level, RADIATED EMISSIONS: C level<br />

*NXL IP21/IP54: CONDUCTED EMISSIONS: C level, RADIATED EMISSIONS: C level<br />

*The factory option can be ordered only as a part of the AC drive, they can not be ordered separately<br />

SUBJECT TO CHANGE WITHOUT NOTICE<br />

Vacon Plc Runsorintie 7 65380 VAASA FINLAND tel.:+358-201-2121 fax: +358 (0)201 212 205 http://www.vacon.com 31


Vacon Plc<br />

AC drive<br />

VACON PLC<br />

Vacon NX_ OPTIONS Enclosure kits<br />

ORDER TYPE CODE SUITABILITY DESCRIPTION<br />

IP5-FR4 FR4, MF4 IP54 kit<br />

IP5-FR5 FR5, MF5 IP54 kit<br />

IP5-FR6 FR6, MF6 IP54 kit<br />

Vacon NX_ OPTIONS Through hole mounting<br />

ORDER TYPE CODE SUITABILITY DESCRIPTION<br />

NX______T____T_ FR4-9, MF4-6 Factory option*<br />

*The factory option can be ordered only as a part of the AC drive, they can not be ordered separately<br />

Vacon NX_OPTIONS Through hole mounting kits IP21<br />

ORDER TYPE CODE SUITABILITY DESCRIPTION<br />

THR-FR4 FR4, MF4 Flange mounting kit for IP21 to the back<br />

THR-FR5 FR5, MF5 Flange mounting kit for IP21 to the back<br />

THR-FR6 FR6, MF6 Flange mounting kit for IP21 to the back<br />

THR-FR7 FR7 Flange mounting kit for IP21 to the back<br />

THR-FR8 FR8 Flange mounting kit for IP21 to the back<br />

THR-FR9 FR9 Flange mounting kit for IP21 to the back<br />

Vacon NX_OPTIONS Through hole mounting kits IP54<br />

ORDER TYPE CODE SUITABILITY DESCRIPTION<br />

THR-FR4-54 FR4, MF4 Flange mounting kit for IP54 to the back<br />

THR-FR5-54 FR5, MF5 Flange mounting kit for IP54 to the back<br />

THR-FR6-54 FR6, MF6 Flange mounting kit for IP54 to the back<br />

VACON NX_ OPTIONS FR9 Floor Assembly Option<br />

ORDER TYPE CODE SUITABILITY DESCRIPTION NOTE<br />

LEG-FR9 FR9 Floor assembly option 493x1650x362 mm *<br />

*FR9 total dimensions (WxHxD) with installed floor assembly option; whitout DC/brake connection box<br />

SUBJECT TO CHANGE WITHOUT NOTICE<br />

Vacon Plc Runsorintie 7 65380 VAASA FINLAND tel.:+358-201-2121 fax: +358 (0)201 212 205 http://www.vacon.com 32


Vacon Plc<br />

AC drive<br />

VACON PLC<br />

Vacon NX_ OPTIONS Display panels, Door installation sets, RS232 cables, Fiber optic cables, Ferrite rings<br />

ORDER TYPE CODE SUITABILITY DESCRIPTION NOTE<br />

Display panels *<br />

PAN-A NXS, NXP Alphanumeric display panel<br />

PAN-B NX_ No display panel, reduction price<br />

PAN-C NXL 7-segment display panel<br />

PAN-RS NXL RS232C adapter panel<br />

PAN-G NXS, NXP Graphical display panel<br />

PAN-F NXS, NXP Dummy keypad (just case, LED's visible)<br />

Door installation sets<br />

DRA-02B NXS, NXP Door installation set for display panel, 2 m cable<br />

DRA-04B NXS, NXP Door installation set for display panel, 4 m cable<br />

DRA-15B NXS, NXP Door installation set for display panel, 15 m cable<br />

DRA-02L NXL Door installation set for display panel, 2 m cable<br />

DRA-04L NXL Door installation set for display panel, 4 m cable<br />

* IP54 UNITS MUST HAVE A PANEL INSTALLED<br />

RS232 cables<br />

RS232C-2M NX_ 2 m RS232 serial link cable, pin to pin<br />

RS232C-4M NX_ 4 m RS232 serial link cable, pin to pin<br />

RS232C-15M NX_ 15 m RS232 serial link cable, pin to pin<br />

RS232-1,5M NXS, NXP 1,5 m RS232 PC cable<br />

Fiber optic cables for system bus (OPT-D1, OPT-D2)<br />

SYS-1M NXP Fiber optic cable (pair), 1 m<br />

SYS-2M NXP Fiber optic cable (pair), 2 m<br />

SYS-4M NXP Fiber optic cable (pair), 4 m<br />

SYS-10M NXP Fiber optic cable (pair), 10 m<br />

Ferrite rings<br />

FER-FGT FR10-14 Ferrite ring assembly* (in NXC please use +OCM option) 6 cores/set<br />

* RECOMMENDED AT LEAST 2 SETS PER EVERY MOTOR CABLE<br />

Vacon NX_ OPTIONS Control unit enclosures for NXP<br />

ORDER TYPE CODE SUITABILITY DESCRIPTION<br />

NXP__________N NXP IP54 Control unit enclosure for OPT-AF option board, standard *<br />

NXP__________O NXP FR4-8 IP54 Control unit enclosure for OPT-AF option board, all circuit boards in the unit varnished *<br />

NXP__________O NXP FR9-FR14 IP54 Control unit enclosure for OPT-AF option board, all circuit boards in the unit varnished *<br />

SX-ECU-IP54 NXP IP54 Control box for OPT-AF board */ **<br />

* It is required that the control unit or the whole drive is IP54 when OPT-AF board is used<br />

**SX-ECU-IP54 is used if the control box is ordered separately or if the existing control unit is wanted to be upgraded up to IP54 because of the OPT-AF<br />

SUBJECT TO CHANGE WITHOUT NOTICE<br />

Vacon Plc Runsorintie 7 65380 VAASA FINLAND tel.:+358-201-2121 fax: +358 (0)201 212 205 http://www.vacon.com 33


Vacon Plc<br />

AC drive<br />

VACON PLC<br />

Vacon NX_ OPTIONS I/O cards<br />

ORDER TYPE CODE SUITABILITY DESCRIPTION<br />

brackets stands for "limited support"<br />

OPT-A1 NXS, NXP 6DI, 1DO, 2AI(mA/V), 1AO(mA/V), +10 Vref, +24 V/EXT+24 V<br />

OPT-A2 NXS, NXP 2RO(NO/NC)<br />

OPT-A3 NXS, NXP 1RO(NO/NC), 1RO(NC), 1 Thermistor<br />

OPT-A4 NXP (NXS) 3DI(Encoder RS422), Out +5 V/+15 V<br />

OPT-A5 NXP (NXS) 3DI(Encoder 10...24V), Out +15 V/+24 V<br />

OPT-A7 NXP Double encoder (Wide Range), 6D1, 2xDO<br />

OPT-A8 NXS, NXP As NXOPTA1, but analog I/O and +10Vref galv. de-coupled as a group<br />

OPT-A9 NXS, NXP As NXOPTA1, but 2,5 mm² terminals<br />

OPT-AA NXL 3DI, 1RO(NO/NC), 1DO<br />

OPT-AE NXP (NXS) Encoder board (Wide Range), 3DI(Encoder 10...24 V), Out +15 V/+24 V, 2DO (encoder divider and direction)<br />

OPT-AF NXP Protection against unexpected restart + ATEX appr. thermistor; control box or whole drive have to be IP54 *<br />

OPT-AI NXL I/O expander board for NXL, 3DI, 1RO (NO), Thermistor<br />

OPT-B1 NXS, NXP, (NXL) 6DI/DO (programmable, DI or DO)<br />

OPT-B2 NX_ 1RO(NO/NC), 1RO(NO), Thermistor<br />

OPT-B4 NX_ 1AI(mA, isolated), 2AO(mA, isolated), +24 V/EXT+24 V<br />

OPT-B5 NX_ 3RO(NO)<br />

OPT-B8 NXS, NXP (NXL) 3Pt100, +24 V/EXT+24 V<br />

OPT-B9 NXS, NXP (NXL) 1RO(NO), 5 pcs of 41...240 VAC input<br />

OPT-BB NXP ENDAT encoder card, 2xDO (RS422)<br />

OPT-BC NXP RESOLVER, 3x DO (Wide Range)<br />

OPT-C2 NX_ RS485 (Modbus/N2)<br />

OPT-C3 NX_ Profibus DP<br />

OPT-C4 NX_ LonWorks<br />

OPT-C5 NX_ Profibus DP (D9 type connector)<br />

OPT-C6 NX_ CANopen (slave)<br />

OPT-C7 NX_ DeviceNet<br />

OPT-C8 NX_ RS485 (D9 type connector, Modbus/RS485)<br />

OPT-CI NX_ MODBUS/TCP<br />

OPT-CJ NX_ BACnet (RS-485)<br />

OPT-CG NXS, NXP S2 PROTOCOL<br />

OPT-D1 NXP System Bus adapter (2x fiber optic cable, please find prices from previous page)<br />

OPT-D2 NXP System Bus (1x fiber optic cable, please find prices from previous page) & CAN-bus (galv. decoupled)<br />

OPT-D3 NXS, NXP RS232 adapter card (not galvanically decoupled)<br />

OPT-D6 NXP CAN-Bus (galv. decoupled)<br />

*It is required that the control unit or the whole drive is IP54 when OPT-AF board is used<br />

Vacon NX_ OPTIONS I/O cards REDUCTION PRICE<br />

OPT-A1r ** NXS, NXP 6DI, 1DO, 2AI(mA/V), 1AO(mA/V), +10 Vref, +24 V/EXT+24 V<br />

OPT-A2r ** NXS, NXP 2RO(NO/NC)<br />

**REDUCTION PRICE, (THIS CARD IS AS STANDARD IN NXS/NXP PRODUCTS)<br />

Vacon NX_ OPTIONS I/O cards VARNISHED<br />

OPT-__-V<br />

Additional varnishing cost per one option card (when the card is ordered separately), e.g. OPT-A3-V<br />

NXL___________V NXL MF4-6 Varnished PCB's, includes all circuit boards in the unit<br />

NX____________V NXS & NXP FR4-8 Varnished PCB's, includes all circuit boards in the unit<br />

NX____________G NXP FR9-FR14 Varnished PCB's, includes all circuit boards in the unit<br />

NX____________B<br />

NXP FR9-FR14, IP00 and standalones Varnished PCB's for FR9-FR14 IP00 modules and standalones<br />

SUBJECT TO CHANGE WITHOUT NOTICE<br />

Vacon Plc Runsorintie 7 65380 VAASA FINLAND tel.:+358-201-2121 fax: +358 (0)201 212 205 http://www.vacon.com 34


Vacon Plc<br />

AC drive<br />

VACON PLC<br />

Vacon NX_OPTIONS Software tools<br />

ORDER TYPE CODE<br />

DESCRIPTION<br />

Vacon NC1131-3 Engineering tool (Personal Licence) *<br />

Vacon NC1131-3 Engineering tool (Company Site Licence) *<br />

Vacon NC1131-3 Engineering tool (Annual Maintenance fee) *<br />

NCDrive and NCLoad<br />

1 cd including both NCDrive and NCLoad<br />

*Personal Licence covers an installation CD-ROM, personal licence excludes updates, training and technical support<br />

Company Site Licence includes unlimited number of copies for one company excluding updates, training and technical support<br />

Annual mainantenance fee includes extensive technical support (by phone and mail) and annual updates<br />

Note! Participation in the Vacon NC1131-3 Engineering training cource is also required in order to get technical support<br />

Please visit out website http://www.vacon.com/911.html for further details concerning NC1131-3 tool and training cource as well as other available training courses<br />

Vacon NX_OPTIONS Application softwares<br />

ORDER TYPE CODE SUITABILITY DESCRIPTION<br />

ASFIFF12 NXS, NXP High Speed Application (>1900 Hz)<br />

APFIFF11 NXP Shaft Synchronization Application<br />

APFIFF12 NXP Position Control Application<br />

Vacon NX_ OPTIONS Other options<br />

ORDER TYPE CODE SUITABILITY DESCRIPTION<br />

NXS Demo<br />

NXS 115-230 V demo case, motor included<br />

NXP Demo<br />

NXP 115-230 V demo case, motor included<br />

NXL Demo 1<br />

NXL MF2 115 V demo, switches and pots included, no motor<br />

NXL Demo 2<br />

NXL MF2 230 V demo, switches and pots included, no motor<br />

NXL Demo 2 MF4<br />

NXL MF4 230 V demo case, motor included<br />

DIN-MF2 NXL MF2 DIN rail assembly option<br />

DIN-MF3 NXL MF3 DIN rail assembly option<br />

Vacon NX_OPTIONS Other material<br />

Marketing materials (e.g. brochures)<br />

Spareparts<br />

Service Tools<br />

SUBJECT TO CHANGE WITHOUT NOTICE<br />

Vacon Plc Runsorintie 7 65380 VAASA FINLAND tel.:+358-201-2121 fax: +358 (0)201 212 205 http://www.vacon.com 35


Vacon Plc<br />

AC drive<br />

VACON PLC<br />

Vacon NXC 380-500 V, 261 A, EMC level H, air-cooled AC drive, 6-pulse supply<br />

ORDER TYPE CODE MOTOR SHAFT POWER AND CURRENT SIZE/PROT. DIMENSIONS WEIGHT<br />

High overload Low overload FR/IP W x H x D<br />

P [kW] I(H) I(overload) P [kW] I(L) [mm] [kg]<br />

NXC02615A2H0SSFA1A2 110 205 308 132 261 FR9/IP21 606x2275x605 308<br />

NXC02615A5H0SSFA1A2 110 205 308 132 261 FR9/IP54 606x2405x605 318<br />

I(H) = nominal current for 150% overload requirement (at max. 50°C ambient temperature)<br />

I(L) = nominal current for 110% overload requirement (at max. 40°C ambient temperature)<br />

I(overload) = maximum 1 min/10 min overload current (high overload)<br />

Vacon NXC Options DESCRIPTION NOTE<br />

+ACH Cabinet heater 50 W 1 x 50 W, requires +TUP *<br />

+ACL Cabinet light Requires +TUP *<br />

+AMO ICB motor operator Including Open/Close push buttons on the door, requires +TUP *<br />

+CIT Cabling Input Top Including +CIT/+COT (W:+400 mm)<br />

+DCM Analog meter + curr.trafo CT on L1<br />

+DVM Analog V-meter + sel.sw. For main voltages<br />

+GPL 100 mm base/plinth For basic drive **<br />

+ICB Circuit breaker MCCB, not with +ILS, +IFU, +IFD or +ICO<br />

+ICO Contactor AC-1 Requires +TUP *<br />

+IFD Fuse switch + aR fuses Not with +ILS, +IFU or +ICB<br />

+IFU aR fuses & base Not with +ILS, +ICB or +IFD<br />

+ILS Load switch Not with +IFU, +ICB or +IFD<br />

+MDC Terminals for DC connect. DC-connection / additional dc/brake chopper terminals<br />

+OCM Common mode chokes To be put on motor cable<br />

+ODU<br />

du/dt filter<br />

* IF UNIT ORDERED WITHOUT CONTROL VOLTAGE TRANSFORMER (ATx), THIS OPTION REQUIRES EXTERNAL 230 V SUPPLY<br />

** NOTE THAT THE OPTIONS THAT AFFECTS ON THE WIDHT OF THE CABINET REQUIRES AN EXTRA +GPL (see NXC common options on page 87)<br />

*** FOR CORRECT ORIENTATION OF DU/DT TERMINALS PLEASE ORDER ALSO +COT IF REQUIRED<br />

Vacon NXC 380-500 V, 261 A, EMC level T, air-cooled AC drive, 6-pulse supply<br />

The prices are the same as H level ones.<br />

Replace the H by T in the order typecode.<br />

SUBJECT TO CHANGE WITHOUT NOTICE<br />

Vacon Plc Runsorintie 7 65380 VAASA FINLAND tel.:+358-201-2121 fax: +358 (0)201 212 205 http://www.vacon.com 36


Vacon Plc<br />

AC drive<br />

VACON PLC<br />

Vacon NXC 380-500 V, 300 A, EMC level H, air-cooled AC drive, 6-pulse supply<br />

ORDER TYPE CODE MOTOR SHAFT POWER AND CURRENT SIZE/PROT. DIMENSIONS WEIGHT<br />

High overload Low overload FR/IP W x H x D<br />

P [kW] I(H) I(overload) P [kW] I(L) [mm] [kg]<br />

NXC03005A2H0SSFA1A2 132 245 368 160 300 FR9/IP21 606x2275x605 308<br />

NXC03005A5H0SSFA1A2 132 245 368 160 300 FR9/IP54 606x2405x605 318<br />

I(H) = nominal current for 150% overload requirement (at max. 50°C ambient temperature)<br />

I(L) = nominal current for 110% overload requirement (at max. 40°C ambient temperature)<br />

I(overload) = maximum 1 min/10 min overload current (high overload)<br />

Vacon NXC Options DESCRIPTION NOTE<br />

+ACH Cabinet heater 50 W 1 x 50 W, requires +TUP *<br />

+ACL Cabinet light Requires +TUP *<br />

+AMO ICB motor operator Including Open/Close push buttons on the door, requires +TUP *<br />

+CIT Cabling Input Top Including +CIT/+COT (W:+400 mm)<br />

+DCM Analog meter + curr.trafo CT on L1<br />

+DVM Analog V-meter + sel.sw. For main voltages<br />

+GPL 100 mm base/plinth For basic drive **<br />

+ICB Circuit breaker MCCB, not with +ILS, +IFU, +IFD or +ICO<br />

+ICO Contactor AC-1 Requires +TUP *<br />

+IFD Fuse switch + aR fuses Not with +ILS, +IFU or +ICB<br />

+IFU aR fuses & base Not with +ILS, +ICB or +IFD<br />

+ILS Load switch Not with +IFU, +ICB or +IFD<br />

+MDC Terminals for DC connect. DC-connection / additional dc/brake chopper terminals<br />

+OCM Common mode chokes To be put on motor cable<br />

+ODU<br />

du/dt filter<br />

* IF UNIT ORDERED WITHOUT CONTROL VOLTAGE TRANSFORMER (ATx), THIS OPTION REQUIRES EXTERNAL 230 V SUPPLY<br />

** NOTE THAT THE OPTIONS THAT AFFECTS ON THE WIDHT OF THE CABINET REQUIRES AN EXTRA +GPL (see NXC common options on page 87)<br />

*** FOR CORRECT ORIENTATION OF DU/DT TERMINALS PLEASE ORDER ALSO +COT IF REQUIRED<br />

Vacon NXC 380-500 V, 300 A, EMC level T, air-cooled AC drive, 6-pulse supply<br />

The prices are the same as H level ones.<br />

Replace the H by T in the order typecode.<br />

SUBJECT TO CHANGE WITHOUT NOTICE<br />

Vacon Plc Runsorintie 7 65380 VAASA FINLAND tel.:+358-201-2121 fax: +358 (0)201 212 205 http://www.vacon.com 37


Vacon Plc<br />

AC drive<br />

VACON PLC<br />

Vacon NXC 380-500 V, 385 A, EMC level L, air-cooled AC drive, 6-pulse supply<br />

ORDER TYPE CODE MOTOR SHAFT POWER AND CURRENT SIZE/PROT. DIMENSIONS WEIGHT<br />

High overload Low overload FR/IP W x H x D<br />

P [kW] I(H) I(overload) P [kW] I(L) [mm] [kg]<br />

NXC03855A2L0SSFA1A2 160 300 450 200 385 FR10/IP21 606x2275x605 371<br />

NXC03855A5L0SSFA1A2 160 300 450 200 385 FR10/IP54 606x2405x605 381<br />

I(H) = nominal current for 150% overload requirement (at max. 40°C ambient temperature)<br />

I(L) = nominal current for 110% overload requirement (at max. 40°C ambient temperature)<br />

I(overload) = maximum 1 min/10 min overload current (high overload)<br />

Vacon NXC Options DESCRIPTION NOTE<br />

+ACH Cabinet heater 50 W 1 x 50 W, requires +TUP *<br />

+ACL Cabinet light Requires +TUP *<br />

+AMO ICB motor operator Including Open/Close push buttons on the door, requires +TUP *<br />

+CIT Cabling Input Top Including +CIT/+COT (W:+400 mm)<br />

+DCM Analog meter + curr.trafo CT on L1<br />

+DVM Analog V-meter + sel.sw. For main voltages<br />

+GPL 100 mm base/plinth For basic drive **<br />

+ICB Circuit breaker MCCB, not with +ILS, +IFU, +IFD or +ICO<br />

+ICO Contactor AC-1 Requires +TUP *<br />

+IFD Fuse switch + aR fuses Not with +ILS, +IFU or +ICB<br />

+IFU aR fuses & base Not with +ILS, +ICB or +IFD<br />

+ILS Load switch Not with +IFU, +ICB or +IFD<br />

+MDC Terminals for DC connect. DC-connection / additional dc/brake chopper terminals<br />

+OCM Common mode chokes To be put on motor cable<br />

+ODU du/dt filter Including +CIT/+COT (W:+400 mm) ***<br />

+OSI Sine wave filter W: +600 mm, Please check the availability from the factory<br />

* IF UNIT ORDERED WITHOUT CONTROL VOLTAGE TRANSFORMER (ATx), THIS OPTION REQUIRES EXTERNAL 230 V SUPPLY<br />

** NOTE THAT THE OPTIONS THAT AFFECTS ON THE WIDHT OF THE CABINET REQUIRES AN EXTRA +GPL (see NXC common options on page 87)<br />

*** FOR CORRECT ORIENTATION OF DU/DT TERMINALS PLEASE ORDER ALSO +COT IF REQUIRED<br />

Vacon NXC 380-500 V, 385 A, EMC level T, air-cooled AC drive, 6-pulse supply<br />

The prices are the same as L level ones.<br />

Replace the L by T in the order typecode.<br />

SUBJECT TO CHANGE WITHOUT NOTICE<br />

Vacon Plc Runsorintie 7 65380 VAASA FINLAND tel.:+358-201-2121 fax: +358 (0)201 212 205 http://www.vacon.com 38


Vacon Plc<br />

AC drive<br />

VACON PLC<br />

Vacon NXC 380-500 V, 460 A, EMC level L, air-cooled AC drive, 6-pulse supply<br />

ORDER TYPE CODE MOTOR SHAFT POWER AND CURRENT SIZE/PROT. DIMENSIONS WEIGHT<br />

High overload Low overload FR/IP W x H x D<br />

P [kW] I(H) I(overload) P [kW] I(L) [mm] [kg]<br />

NXC04605A2L0SSFA1A2 200 385 578 250 460 FR10/IP21 606x2275x605 403<br />

NXC04605A5L0SSFA1A2 200 385 578 250 460 FR10/IP54 606x2405x605 413<br />

I(H) = nominal current for 150% overload requirement (at max. 40°C ambient temperature)<br />

I(L) = nominal current for 110% overload requirement (at max. 40°C ambient temperature)<br />

I(overload) = maximum 1 min/10 min overload current (high overload)<br />

Vacon NXC Options DESCRIPTION NOTE<br />

+ACH Cabinet heater 50 W 1 x 50 W, requires +TUP *<br />

+ACL Cabinet light Requires +TUP *<br />

+AMO ICB motor operator Including Open/Close push buttons on the door, requires +TUP *<br />

+CIT Cabling Input Top Including +CIT/+COT (W:+400 mm)<br />

+DCM Analog meter + curr.trafo CT on L1<br />

+DVM Analog V-meter + sel.sw. For main voltages<br />

+GPL 100 mm base/plinth For basic drive **<br />

+ICB Circuit breaker MCCB, not with +ILS, +IFU, +IFD or +ICO<br />

+ICO Contactor AC-1 Requires +TUP *<br />

+IFD Fuse switch + aR fuses Not with +ILS, +IFU or +ICB<br />

+IFU aR fuses & base Not with +ILS, +ICB or +IFD<br />

+ILS Load switch Not with +IFU, +ICB or +IFD<br />

+MDC Terminals for DC connect. DC-connection / additional dc/brake chopper terminals<br />

+OCM Common mode chokes To be put on motor cable<br />

+ODU du/dt filter Including +CIT/+COT (W:+400 mm) ***<br />

+OSI Sine wave filter W: +600 mm, Please check the availability from the factory<br />

* IF UNIT ORDERED WITHOUT CONTROL VOLTAGE TRANSFORMER (ATx), THIS OPTION REQUIRES EXTERNAL 230 V SUPPLY<br />

** NOTE THAT THE OPTIONS THAT AFFECTS ON THE WIDHT OF THE CABINET REQUIRES AN EXTRA +GPL (see NXC common options on page 87)<br />

*** FOR CORRECT ORIENTATION OF DU/DT TERMINALS PLEASE ORDER ALSO +COT IF REQUIRED<br />

Vacon NXC 380-500 V, 460 A, EMC level T, air-cooled AC drive, 6-pulse supply<br />

The prices are the same as L level ones.<br />

Replace the L by T in the order typecode.<br />

SUBJECT TO CHANGE WITHOUT NOTICE<br />

Vacon Plc Runsorintie 7 65380 VAASA FINLAND tel.:+358-201-2121 fax: +358 (0)201 212 205 http://www.vacon.com 39


Vacon Plc<br />

AC drive<br />

VACON PLC<br />

Vacon NXC 380-500 V, 520 A, EMC level L, air-cooled AC drive, 6-pulse supply<br />

ORDER TYPE CODE MOTOR SHAFT POWER AND CURRENT SIZE/PROT. DIMENSIONS WEIGHT<br />

High overload Low overload FR/IP W x H x D<br />

P [kW] I(H) I(overload) P [kW] I(L) [mm] [kg]<br />

NXC05205A2L0SSFA1A2 250 460 690 250 520 FR10/IP21 606x2275x605 403<br />

NXC05205A5L0SSFA1A2 250 460 690 250 520 FR10/IP54 606x2405x605 413<br />

I(H) = nominal current for 150% overload requirement (at max. 40°C ambient temperature)<br />

I(L) = nominal current for 110% overload requirement (at max. 40°C ambient temperature)<br />

I(overload) = maximum 1 min/10 min overload current (high overload)<br />

Vacon NXC Options DESCRIPTION NOTE<br />

+ACH Cabinet heater 50 W 1 x 50 W, requires +TUP *<br />

+ACL Cabinet light Requires +TUP *<br />

+AMO ICB motor operator Including Open/Close push buttons on the door, requires +TUP *<br />

+CIT Cabling Input Top Including +CIT/+COT (W:+400 mm)<br />

+DCM Analog meter + curr.trafo CT on L1<br />

+DVM Analog V-meter + sel.sw. For main voltages<br />

+GPL 100 mm base/plinth For basic drive **<br />

+ICB Circuit breaker MCCB, not with +ILS, +IFU, +IFD or +ICO<br />

+ICO Contactor AC-1 Requires +TUP *<br />

+IFD Fuse switch + aR fuses Not with +ILS, +IFU or +ICB<br />

+IFU aR fuses & base Not with +ILS, +ICB or +IFD<br />

+ILS Load switch Not with +IFU, +ICB or +IFD<br />

+MDC Terminals for DC connect. DC-connection / additional dc/brake chopper terminals<br />

+OCM Common mode chokes To be put on motor cable<br />

+ODU du/dt filter Including +CIT/+COT (W:+400 mm) ***<br />

+OSI Sine wave filter W: +600 mm, Please check the availability from the factory<br />

* IF UNIT ORDERED WITHOUT CONTROL VOLTAGE TRANSFORMER (ATx), THIS OPTION REQUIRES EXTERNAL 230 V SUPPLY<br />

** NOTE THAT THE OPTIONS THAT AFFECTS ON THE WIDHT OF THE CABINET REQUIRES AN EXTRA +GPL (see NXC common options on page 87)<br />

*** FOR CORRECT ORIENTATION OF DU/DT TERMINALS PLEASE ORDER ALSO +COT IF REQUIRED<br />

Vacon NXC 380-500 V, 520 A, EMC level T, air-cooled AC drive, 6-pulse supply<br />

The prices are the same as L level ones.<br />

Replace the L by T in the order typecode.<br />

SUBJECT TO CHANGE WITHOUT NOTICE<br />

Vacon Plc Runsorintie 7 65380 VAASA FINLAND tel.:+358-201-2121 fax: +358 (0)201 212 205 http://www.vacon.com 40


Vacon Plc<br />

AC drive<br />

VACON PLC<br />

Vacon NXC 380-500 V, 590 A, EMC level L, air-cooled AC drive, 6-pulse supply<br />

ORDER TYPE CODE MOTOR SHAFT POWER AND CURRENT SIZE/PROT. DIMENSIONS WEIGHT<br />

High overload Low overload FR/IP W x H x D<br />

P [kW] I(H) I(overload) P [kW] I(L) [mm] [kg]<br />

NXC05905A2L0SSFA1A2 250 520 780 315 590 FR11/IP21 806x2275x605 577<br />

NXC05905A5L0SSFA1A2 250 520 780 315 590 FR11/IP54 806x2405x605 590<br />

I(H) = nominal current for 150% overload requirement (at max. 40°C ambient temperature)<br />

I(L) = nominal current for 110% overload requirement (at max. 40°C ambient temperature)<br />

I(overload) = maximum 1 min/10 min overload current (high overload)<br />

Vacon NXC Options DESCRIPTION NOTE<br />

+ACH Cabinet heater 50 W 1 x 50 W, requires +TUP *<br />

+ACL Cabinet light Requires +TUP *<br />

+AMO ICB motor operator Including Open/Close push buttons on the door, requires +TUP *<br />

+CIT Cabling Input Top Including +CIT/+COT (W:+400 mm)<br />

+DCM Analog meter + curr.trafo CT on L1<br />

+DVM Analog V-meter + sel.sw. For main voltages<br />

+GPL 100 mm base/plinth For basic drive **<br />

+ICB Circuit breaker MCCB, not with +ILS, +IFU, +IFD or +ICO *<br />

+ICO Contactor AC-1 Requires +TUP *<br />

+IFD Fuse switch + aR fuses Not with +ILS, +IFU or +ICB<br />

+IFU aR fuses & base Not with +ILS, +ICB or +IFD<br />

+ILS Load switch Not with +IFU, +ICB or +IFD<br />

+MDC Terminals for DC connect. DC-connection / additional dc/brake chopper terminals<br />

+OCM Common mode chokes To be put on motor cable<br />

+ODU du/dt filter Including +CIT/+COT (W:+400 mm) ***<br />

+OSI Sine wave filter W: +800 mm, Please check the availability from the factory<br />

* IF UNIT ORDERED WITHOUT CONTROL VOLTAGE TRANSFORMER (ATx), THIS OPTION REQUIRES EXTERNAL 230 V SUPPLY<br />

** NOTE THAT THE OPTIONS THAT AFFECTS ON THE WIDHT OF THE CABINET REQUIRES AN EXTRA +GPL (see NXC common options on page 87)<br />

*** FOR CORRECT ORIENTATION OF DU/DT TERMINALS PLEASE ORDER ALSO +COT IF REQUIRED<br />

Vacon NXC 380-500 V, 590 A, EMC level T, air-cooled AC drive, 6-pulse supply<br />

The prices are the same as L level ones.<br />

Replace the L by T in the order typecode.<br />

SUBJECT TO CHANGE WITHOUT NOTICE<br />

Vacon Plc Runsorintie 7 65380 VAASA FINLAND tel.:+358-201-2121 fax: +358 (0)201 212 205 http://www.vacon.com 41


Vacon Plc<br />

AC drive<br />

VACON PLC<br />

Vacon NXC 380-500 V, 650 A, EMC level L, air-cooled AC drive, 6-pulse supply<br />

ORDER TYPE CODE MOTOR SHAFT POWER AND CURRENT SIZE/PROT. DIMENSIONS WEIGHT<br />

High overload Low overload FR/IP W x H x D<br />

P [kW] I(H) I(overload) P [kW] I(L) [mm] [kg]<br />

NXC06505A2L0SSFA1A2 315 590 885 355 650 FR11/IP21 806x2275x605 577<br />

NXC06505A5L0SSFA1A2 315 590 885 355 650 FR11/IP54 806x2405x605 590<br />

I(H) = nominal current for 150% overload requirement (at max. 40°C ambient temperature)<br />

I(L) = nominal current for 110% overload requirement (at max. 40°C ambient temperature)<br />

I(overload) = maximum 1 min/10 min overload current (high overload)<br />

Vacon NXC Options DESCRIPTION NOTE<br />

+ACH Cabinet heater 50 W 1 x 50 W, requires +TUP *<br />

+ACL Cabinet light Requires +TUP *<br />

+AMO ICB motor operator Including Open/Close push buttons on the door, requires +TUP *<br />

+CIT Cabling Input Top Including +CIT/+COT (W:+400 mm)<br />

+DCM Analog meter + curr.trafo CT on L1<br />

+DVM Analog V-meter + sel.sw. For main voltages<br />

+GPL 100 mm base/plinth For basic drive **<br />

+ICB Circuit breaker MCCB, not with +ILS, +IFU, +IFD or +ICO *<br />

+ICO Contactor AC-1 Requires +TUP *<br />

+IFD Fuse switch + aR fuses Not with +ILS, +IFU or +ICB<br />

+IFU aR fuses & base Not with +ILS, +ICB or +IFD<br />

+ILS Load switch Not with +IFU, +ICB or +IFD<br />

+MDC Terminals for DC connect. DC-connection / additional dc/brake chopper terminals<br />

+OCM Common mode chokes To be put on motor cable<br />

+ODU du/dt filter Including +CIT/+COT (W:+400 mm) ***<br />

+OSI Sine wave filter W: +800 mm, Please check the availability from the factory<br />

* IF UNIT ORDERED WITHOUT CONTROL VOLTAGE TRANSFORMER (ATx), THIS OPTION REQUIRES EXTERNAL 230 V SUPPLY<br />

** NOTE THAT THE OPTIONS THAT AFFECTS ON THE WIDHT OF THE CABINET REQUIRES AN EXTRA +GPL (see NXC common options on page 87)<br />

*** FOR CORRECT ORIENTATION OF DU/DT TERMINALS PLEASE ORDER ALSO +COT IF REQUIRED<br />

Vacon NXC 380-500 V, 650 A, EMC level T, air-cooled AC drive, 6-pulse supply<br />

The prices are the same as L level ones.<br />

Replace the L by T in the order typecode.<br />

SUBJECT TO CHANGE WITHOUT NOTICE<br />

Vacon Plc Runsorintie 7 65380 VAASA FINLAND tel.:+358-201-2121 fax: +358 (0)201 212 205 http://www.vacon.com 42


Vacon Plc<br />

AC drive<br />

VACON PLC<br />

Vacon NXC 380-500 V, 730 A, EMC level L, air-cooled AC drive, 6-pulse supply<br />

ORDER TYPE CODE MOTOR SHAFT POWER AND CURRENT SIZE/PROT. DIMENSIONS WEIGHT<br />

High overload Low overload FR/IP W x H x D<br />

P [kW] I(H) I(overload) P [kW] I(L) [mm] [kg]<br />

NXC07305A2L0SSFA1A2 355 650 975 400 730 FR11/IP21 806x2275x605 577<br />

NXC07305A5L0SSFA1A2 355 650 975 400 730 FR11/IP54 806x2445x605 590<br />

I(H) = nominal current for 150% overload requirement (at max. 40°C ambient temperature)<br />

I(L) = nominal current for 110% overload requirement (at max. 40°C ambient temperature)<br />

I(overload) = maximum 1 min/10 min overload current (high overload)<br />

Vacon NXC Options DESCRIPTION NOTE<br />

+ACH Cabinet heater 50 W 1 x 50 W, requires +TUP *<br />

+ACL Cabinet light Requires +TUP *<br />

+AMO ICB motor operator Including Open/Close push buttons on the door, requires +TUP *<br />

+CIT Cabling Input Top Including +CIT/+COT (W:+400 mm) **<br />

+DCM Analog meter + curr.trafo CT on L1<br />

+DVM Analog V-meter + sel.sw. For main voltages<br />

+GPL 100 mm base/plinth For basic drive **<br />

+ICB Circuit breaker MCCB, not with +ILS, +IFU, +IFD or +ICO, requires +TUP *<br />

+ICO Contactor AC-1 Requires +TUP *<br />

+IFD Fuse switch + aR fuses Not with +ILS, +IFU or +ICB<br />

+IFU aR fuses & base Not with +ILS, +ICB or +IFD<br />

+ILS Load switch Not with +IFU, +ICB or +IFD<br />

+MDC Terminals for DC connect. DC-connection / additional dc/brake chopper terminals<br />

+OCM Common mode chokes To be put on motor cable<br />

+ODU du/dt filter Including +CIT/+COT (W:+400 mm) ***<br />

+OSI Sine wave filter W: +800 mm, Please check the availability from the factory<br />

* IF UNIT ORDERED WITHOUT CONTROL VOLTAGE TRANSFORMER (ATx), THIS OPTION REQUIRES EXTERNAL 230 V SUPPLY<br />

** NOTE THAT THE OPTIONS THAT AFFECTS ON THE WIDHT OF THE CABINET REQUIRES AN EXTRA +GPL (see NXC common options on page 87)<br />

*** FOR CORRECT ORIENTATION OF DU/DT TERMINALS PLEASE ORDER ALSO +COT IF REQUIRED<br />

Vacon NXC 380-500 V, 730 A, EMC level T, air-cooled AC drive, 6-pulse supply<br />

The prices are the same as L level ones.<br />

Replace the L by T in the order typecode.<br />

SUBJECT TO CHANGE WITHOUT NOTICE<br />

Vacon Plc Runsorintie 7 65380 VAASA FINLAND tel.:+358-201-2121 fax: +358 (0)201 212 205 http://www.vacon.com 43


Vacon Plc<br />

AC drive<br />

VACON PLC<br />

Vacon NXC 380-500 V, 820 A, EMC level L, air-cooled AC drive, 6-pulse supply<br />

ORDER TYPE CODE MOTOR SHAFT POWER AND CURRENT SIZE/PROT. DIMENSIONS WEIGHT<br />

High overload Low overload FR/IP W x H x D<br />

P [kW] I(H) I(overload) P [kW] I(L) [mm] [kg]<br />

NXC08205A2L0SSFA1A2 400 730 1095 450 820 FR12/IP21 1206x2275x605 810<br />

NXC08205A5L0SSFA1A2 400 730 1095 450 820 FR12/IP54 1206x2405x605 830<br />

I(H) = nominal current for 150% overload requirement (at max. 40°C ambient temperature)<br />

I(L) = nominal current for 110% overload requirement (at max. 40°C ambient temperature)<br />

I(overload) = maximum 1 min/10 min overload current (high overload)<br />

Vacon NXC Options DESCRIPTION NOTE<br />

+ACH Cabinet heater 50 W 1 x 50 W, requires +TUP *<br />

+ACL Cabinet light Requires +TUP *<br />

+CIT Cabling Input Top Including +CIT/+COT (W:+400 mm)<br />

+DCM Analog meter + curr.trafo CT on L1<br />

+DVM Analog V-meter + sel.sw. For main voltages<br />

+GPL 100 mm base/plinth For basic drive **<br />

+ICB Circuit breaker, including +AMO MCCB, not with +ILS, +IFU, +IFD or +ICO, requires +TUP *<br />

+ICO Contactor AC-1 Requires +TUP *<br />

+IFD Fuse switch + aR fuses Not with +ILS, +IFU or +ICB<br />

+IFU aR fuses & base Not with +ILS, +ICB or +IFD<br />

+ILS Load switch Not with +IFU, +ICB or +IFD<br />

+MDC Terminals for resistor connect. Brake chopper terminals<br />

+OCM Common mode chokes To be put on motor cable<br />

+ODU du/dt filter Including +CIT/+COT (W:+400 mm) ***<br />

+OSI Sine wave filter W: +2x600 mm, Please check the availability from the factory<br />

* IF UNIT ORDERED WITHOUT CONTROL VOLTAGE TRANSFORMER (ATx), THIS OPTION REQUIRES EXTERNAL 230 V SUPPLY<br />

** NOTE THAT THE OPTIONS THAT AFFECTS ON THE WIDHT OF THE CABINET REQUIRES AN EXTRA +GPL (see NXC common options on page 87)<br />

*** FOR CORRECT ORIENTATION OF DU/DT TERMINALS PLEASE ORDER ALSO +COT IF REQUIRED<br />

Vacon NXC 380-500 V, 820 A, EMC level T, air-cooled AC drive, 6-pulse supply<br />

The prices are the same as L level ones.<br />

Replace the L by T in the order typecode.<br />

SUBJECT TO CHANGE WITHOUT NOTICE<br />

Vacon Plc Runsorintie 7 65380 VAASA FINLAND tel.:+358-201-2121 fax: +358 (0)201 212 205 http://www.vacon.com 44


Vacon Plc<br />

AC drive<br />

VACON PLC<br />

Vacon NXC 380-500 V, 920 A, EMC level L, air-cooled AC drive, 6-pulse supply<br />

ORDER TYPE CODE MOTOR SHAFT POWER AND CURRENT SIZE/PROT. DIMENSIONS WEIGHT<br />

High overload Low overload FR/IP W x H x D<br />

P [kW] I(H) I(overload) P [kW] I(L) [mm] [kg]<br />

NXC09205A2L0SSFA1A2 450 820 1230 500 920 FR12/IP21 1206x2275x605 810<br />

NXC09205A5L0SSFA1A2 450 820 1230 500 920 FR12/IP54 1206x2405x605 830<br />

I(H) = nominal current for 150% overload requirement (at max. 40°C ambient temperature)<br />

I(L) = nominal current for 110% overload requirement (at max. 40°C ambient temperature)<br />

I(overload) = maximum 1 min/10 min overload current (high overload)<br />

Vacon NXC Options DESCRIPTION NOTE<br />

+ACH Cabinet heater 50 W 1 x 50 W, requires +TUP *<br />

+ACL Cabinet light Requires +TUP *<br />

+CIT Cabling Input Top Including +CIT/+COT (W:+400 mm)<br />

+DCM Analog meter + curr.trafo CT on L1<br />

+DVM Analog V-meter + sel.sw. For main voltages<br />

+GPL 100 mm base/plinth For basic drive **<br />

+ICB Circuit breaker, including +AMO MCCB, not with +ILS, +IFU, +IFD or +ICO, requires +TUP *<br />

+ICO Contactor AC-1 Requires +TUP *<br />

+IFD Fuse switch + aR fuses Not with +ILS, +IFU or +ICB<br />

+IFU aR fuses & base Not with +ILS, +ICB or +IFD<br />

+ILS Load switch Not with +IFU, +ICB or +IFD<br />

+MDC Terminals for resistor connect. Brake chopper terminals<br />

+OCM Common mode chokes To be put on motor cable<br />

+ODU du/dt filter Including +CIT/+COT (W:+400 mm) ***<br />

+OSI Sine wave filter W: +2x600 mm, Please check the availability from the factory<br />

* IF UNIT ORDERED WITHOUT CONTROL VOLTAGE TRANSFORMER (ATx), THIS OPTION REQUIRES EXTERNAL 230 V SUPPLY<br />

** NOTE THAT THE OPTIONS THAT AFFECTS ON THE WIDHT OF THE CABINET REQUIRES AN EXTRA +GPL (see NXC common options on page 87)<br />

*** FOR CORRECT ORIENTATION OF DU/DT TERMINALS PLEASE ORDER ALSO +COT IF REQUIRED<br />

Vacon NXC 380-500 V, 920 A, EMC level T, air-cooled AC drive, 6-pulse supply<br />

The prices are the same as L level ones.<br />

Replace the L by T in the order typecode.<br />

SUBJECT TO CHANGE WITHOUT NOTICE<br />

Vacon Plc Runsorintie 7 65380 VAASA FINLAND tel.:+358-201-2121 fax: +358 (0)201 212 205 http://www.vacon.com 45


Vacon Plc<br />

AC drive<br />

VACON PLC<br />

Vacon NXC 380-500 V, 1030 A, EMC level L, air-cooled AC drive, 6-pulse supply<br />

ORDER TYPE CODE MOTOR SHAFT POWER AND CURRENT SIZE/PROT. DIMENSIONS WEIGHT<br />

High overload Low overload FR/IP W x H x D<br />

P [kW] I(H) I(overload) P [kW] I(L) [mm] [kg]<br />

NXC10305A2L0SSFA1A2 500 920 1380 560 1030 FR12/IP21 1206x2275x605 810<br />

NXC10305A5L0SSFA1A2 500 920 1380 560 1030 FR12/IP54 1206x2405x605 830<br />

I(H) = nominal current for 150% overload requirement (at max. 40°C ambient temperature)<br />

I(L) = nominal current for 110% overload requirement (at max. 40°C ambient temperature)<br />

I(overload) = maximum 1 min/10 min overload current (high overload)<br />

Vacon NXC Options DESCRIPTION NOTE<br />

+ACH Cabinet heater 50 W 1 x 50 W, requires +TUP *<br />

+ACL Cabinet light Requires +TUP *<br />

+CIT Cabling Input Top Including +CIT/+COT (W:+400 mm)<br />

+DCM Analog meter + curr.trafo CT on L1<br />

+DVM Analog V-meter + sel.sw. For main voltages<br />

+GPL 100 mm base/plinth For basic drive **<br />

+ICB Circuit breaker, including +AMO MCCB, not with +ILS, +IFU, +IFD or +ICO, requires +TUP *<br />

+ICO Contactor AC-1 Requires +TUP *<br />

+IFD Fuse switch + aR fuses Not with +ILS, +IFU or +ICB<br />

+IFU aR fuses & base Not with +ILS, +ICB or +IFD<br />

+ILS Load switch Not with +IFU, +ICB or +IFD<br />

+MDC Terminals for resistor connect. Brake chopper terminals<br />

+OCM Common mode chokes To be put on motor cable<br />

+ODU du/dt filter Including +CIT/+COT (W:+400 mm) ***<br />

+OSI Sine wave filter W: +2x600 mm, Please check the availability from the factory<br />

* IF UNIT ORDERED WITHOUT CONTROL VOLTAGE TRANSFORMER (ATx), THIS OPTION REQUIRES EXTERNAL 230 V SUPPLY<br />

** NOTE THAT THE OPTIONS THAT AFFECTS ON THE WIDHT OF THE CABINET REQUIRES AN EXTRA +GPL (see NXC common options on page 87)<br />

*** FOR CORRECT ORIENTATION OF DU/DT TERMINALS PLEASE ORDER ALSO +COT IF REQUIRED<br />

Vacon NXC 380-500 V, 1030 A, EMC level T, air-cooled AC drive, 6-pulse supply<br />

The prices are the same as L level ones.<br />

Replace the L by T in the order typecode.<br />

SUBJECT TO CHANGE WITHOUT NOTICE<br />

Vacon Plc Runsorintie 7 65380 VAASA FINLAND tel.:+358-201-2121 fax: +358 (0)201 212 205 http://www.vacon.com 46


Vacon Plc<br />

AC drive<br />

VACON PLC<br />

Vacon NXC 380-500 V, 1150 A, EMC level L, air-cooled AC drive, 6-pulse supply<br />

ORDER TYPE CODE MOTOR SHAFT POWER AND CURRENT SIZE/PROT. DIMENSIONS WEIGHT<br />

High overload Low overload FR/IP W x H x D<br />

P [kW] I(H) I(overload) P [kW] I(L) [mm] [kg]<br />

NXC11505A2L0SSFA1A2 +IFD 560 1030 1545 630 1150 FR13/IP21 1406x2275x605 1050<br />

NXC11505A5L0SSFA1A2 +IFD 560 1030 1545 630 1150 FR13/IP54 1406x2405x605 1060<br />

+IFD (Load switch + bolt-on fuses) INCLUDED AS STANDARD<br />

I(H) = nominal current for 150% overload requirement (at max. 40°C ambient temperature)<br />

I(L) = nominal current for 110% overload requirement (at max. 40°C ambient temperature)<br />

I(overload) = maximum 1 min/10 min overload current (high overload)<br />

Vacon NXC Options DESCRIPTION NOTE<br />

+ACH Cabinet heater 50 W 1 x 50 W, requires +TUP *<br />

+ACL Cabinet light Requires +TUP *<br />

+CIT Cabling Input Top Including +CIT/+COT (W:+400 mm)<br />

+DCM Analog meter + curr.trafo CT on L1<br />

+DVM Analog V-meter + sel.sw. For main voltages<br />

+GPL 100 mm base/plinth For basic drive **<br />

+ICB Circuit breaker, including +AMO MCCB, not with +IFD (upgrades +IFD to +ICB), requires +TUP *<br />

+MDC Terminals for DC connect. Including +CIT/+COT (W:+400 mm)<br />

+OCM Common mode chokes To be put on motor cable<br />

+ODU<br />

du/dt filter<br />

+OSI Sine wave filter W: +800 mm, Please check the availability from the factory<br />

* IF UNIT ORDERED WITHOUT CONTROL VOLTAGE TRANSFORMER (ATx), THIS OPTION REQUIRES EXTERNAL 230 V SUPPLY<br />

** NOTE THAT THE OPTIONS THAT AFFECTS ON THE WIDHT OF THE CABINET REQUIRES AN EXTRA +GPL (see NXC common options on page 87)<br />

Vacon NXC 380-500 V, 1150 A, EMC level T, air-cooled AC drive, 6-pulse supply<br />

The prices are the same as L level ones.<br />

Replace the L by T in the order typecode.<br />

SUBJECT TO CHANGE WITHOUT NOTICE<br />

Vacon Plc Runsorintie 7 65380 VAASA FINLAND tel.:+358-201-2121 fax: +358 (0)201 212 205 http://www.vacon.com 47


Vacon Plc<br />

AC drive<br />

VACON PLC<br />

Vacon NXC 380-500 V, 1300 A, EMC level L, air-cooled AC drive, 6-pulse supply<br />

ORDER TYPE CODE MOTOR SHAFT POWER AND CURRENT SIZE/PROT. DIMENSIONS WEIGHT<br />

High overload Low overload FR/IP W x H x D<br />

P [kW] I(H) I(overload) P [kW] I(L) [mm] [kg]<br />

NXC13005A2L0SSFA1A2 +IFD 630 1150 1725 710 1300 FR13/IP21 1606x2275x605 1250<br />

NXC13005A5L0SSFA1A2 +IFD 630 1150 1725 710 1300 FR13/IP54 1606x2405x605 1260<br />

+IFD (Load switch + bolt-on fuses) INCLUDED AS STANDARD<br />

I(H) = nominal current for 150% overload requirement (at max. 40°C ambient temperature)<br />

I(L) = nominal current for 110% overload requirement (at max. 40°C ambient temperature)<br />

I(overload) = maximum 1 min/10 min overload current (high overload)<br />

Vacon NXC Options DESCRIPTION NOTE<br />

+ACH Cabinet heater 50 W 1 x 50 W, requires +TUP *<br />

+ACL Cabinet light Requires +TUP *<br />

+CIT Cabling Input Top Including +CIT/+COT (W:+400 mm)<br />

+DCM Analog meter + curr.trafo CT on L1<br />

+DVM Analog V-meter + sel.sw. For main voltages<br />

+GPL 100 mm base/plinth For basic drive **<br />

+ICB Circuit breaker, including +AMO MCCB, not with +IFD (upgrades +IFD to +ICB), requires +TUP *<br />

+MDC Terminals for DC connect. Including +CIT/+COT (W:+400 mm)<br />

+OCM Common mode chokes To be put on motor cable<br />

+ODU<br />

du/dt filter<br />

+OSI Sine wave filter W: +800 mm, Please check the availability from the factory<br />

* IF UNIT ORDERED WITHOUT CONTROL VOLTAGE TRANSFORMER (ATx), THIS OPTION REQUIRES EXTERNAL 230 V SUPPLY<br />

** NOTE THAT THE OPTIONS THAT AFFECTS ON THE WIDHT OF THE CABINET REQUIRES AN EXTRA +GPL (see NXC common options on page 87)<br />

Vacon NXC 380-500 V, 1300 A, EMC level T, air-cooled AC drive, 6-pulse supply<br />

The prices are the same as L level ones.<br />

Replace the L by T in the order typecode.<br />

SUBJECT TO CHANGE WITHOUT NOTICE<br />

Vacon Plc Runsorintie 7 65380 VAASA FINLAND tel.:+358-201-2121 fax: +358 (0)201 212 205 http://www.vacon.com 48


Vacon Plc<br />

AC drive<br />

VACON PLC<br />

Vacon NXC 380-500 V, 1450 A, EMC level L, air-cooled AC drive, 6-pulse supply<br />

ORDER TYPE CODE MOTOR SHAFT POWER AND CURRENT SIZE/PROT. DIMENSIONS WEIGHT<br />

High overload Low overload FR/IP W x H x D<br />

P [kW] I(H) I(overload) P [kW] I(L) [mm] [kg]<br />

NXC14505A2L0SSFA1A2 +IFD 710 1300 1950 800 1450 FR13/IP21 1606x2275x605 1250<br />

NXC14505A5L0SSFA1A2 +IFD 710 1300 1950 800 1450 FR13/IP54 1606x2405x605 1260<br />

+IFD (Load switch + bolt-on fuses) INCLUDED AS STANDARD<br />

I(H) = nominal current for 150% overload requirement (at max. 40°C ambient temperature)<br />

I(L) = nominal current for 110% overload requirement (at max. 40°C ambient temperature)<br />

I(overload) = maximum 1 min/10 min overload current (high overload)<br />

Vacon NXC Options DESCRIPTION NOTE<br />

+ACH Cabinet heater 50 W 1 x 50 W, requires +TUP *<br />

+ACL Cabinet light Requires +TUP *<br />

+CIT Cabling Input Top Including +CIT/+COT (W:+400 mm)<br />

+DCM Analog meter + curr.trafo CT on L1<br />

+DVM Analog V-meter + sel.sw. For main voltages<br />

+GPL 100 mm base/plinth For basic drive **<br />

+ICB Circuit breaker, including +AMO MCCB, not with +IFD (upgrades +IFD to +ICB), requires +TUP *<br />

+MDC Terminals for DC connect. Including +CIT/+COT (W:+400 mm)<br />

+OCM Common mode chokes To be put on motor cable<br />

+ODU<br />

du/dt filter<br />

+OSI Sine wave filter W: +800 mm, Please check the availability from the factory<br />

* IF UNIT ORDERED WITHOUT CONTROL VOLTAGE TRANSFORMER (ATx), THIS OPTION REQUIRES EXTERNAL 230 V SUPPLY<br />

** NOTE THAT THE OPTIONS THAT AFFECTS ON THE WIDHT OF THE CABINET REQUIRES AN EXTRA +GPL (see NXC common options on page 87)<br />

Vacon NXC 380-500 V, 1450 A, EMC level T, air-cooled AC drive, 6-pulse supply<br />

The prices are the same as L level ones.<br />

Replace the L by T in the order typecode.<br />

SUBJECT TO CHANGE WITHOUT NOTICE<br />

Vacon Plc Runsorintie 7 65380 VAASA FINLAND tel.:+358-201-2121 fax: +358 (0)201 212 205 http://www.vacon.com 49


Vacon Plc<br />

AC drive<br />

VACON PLC<br />

Vacon NXC 380-500 V, 1770 A, EMC level L, air-cooled AC drive, 6-pulse supply<br />

ORDER TYPE CODE MOTOR SHAFT POWER AND CURRENT SIZE/PROT. DIMENSIONS WEIGHT<br />

High overload Low overload FR/IP W x H x D<br />

P [kW] I(H) I(overload) P [kW] I(L) [mm] [kg]<br />

NXC17705A2L0SSFA1A2+ODU+ICB+AMO+TUP 900 1600 2400 1000 1770 FR14/IP21 2806x2275x605 2250<br />

NXC17705A5L0SSFA1A2+ODU+ICB+AMO+TUP 900 1600 2400 1000 1770 FR14/IP54 2806x2405x605 2280<br />

+ODU (du/dt filter), +ICB (MCCB), +AMO (ICB motor operator), +TUP INCLUDED AS STANDARD *<br />

I(H) = nominal current for 150% overload requirement (at max. 40°C ambient temperature)<br />

I(L) = nominal current for 110% overload requirement (at max. 40°C ambient temperature)<br />

I(overload) = maximum 1 min/10 min overload current (high overload)<br />

Vacon NXC Options DESCRIPTION NOTE<br />

+ACH Cabinet heater 50 W 1 x 50 W, requires +TUP *<br />

+ACL Cabinet light Requires +TUP *<br />

+CIT Cabling Input Top Including +CIT/+COT (W:+400 mm)<br />

+DCM Analog meter + curr.trafo CT on L1<br />

+DVM Analog V-meter + sel.sw. For main voltages<br />

+GPL 100 mm base/plinth For basic drive **<br />

+OCM Common mode chokes To be put on motor cable<br />

+OSI Sine wave filter *** W: +2x800 mm<br />

* IF UNIT ORDERED WITHOUT CONTROL VOLTAGE TRANSFORMER (ATx), THIS OPTION REQUIRES EXTERNAL 230 V SUPPLY<br />

** NOTE THAT THE OPTIONS THAT AFFECTS ON THE WIDHT OF THE CABINET REQUIRES AN EXTRA +GPL (see NXC common options on page 87)<br />

***PLEASE CHECK THE AVAILABILITY FROM THE FACTORY<br />

Vacon NXC 380-500 V, 1770 A, EMC level T, air-cooled AC drive, 6-pulse supply<br />

The prices are the same as L level ones.<br />

Replace the L by T in the order typecode.<br />

SUBJECT TO CHANGE WITHOUT NOTICE<br />

Vacon Plc Runsorintie 7 65380 VAASA FINLAND tel.:+358-201-2121 fax: +358 (0)201 212 205 http://www.vacon.com 50


Vacon Plc<br />

AC drive<br />

VACON PLC<br />

Vacon NXC 380-500 V, 2150 A, EMC level L, air-cooled AC drive, 6-pulse supply<br />

ORDER TYPE CODE MOTOR SHAFT POWER AND CURRENT SIZE/PROT. DIMENSIONS WEIGHT<br />

High overload Low overload FR/IP W x H x D<br />

P [kW] I(H) I(overload) P [kW] I(L) [mm] [kg]<br />

NXC21505A2L0SSFA1A2+ODU+ICB+AMO+TUP 1100 1940 2910 1200 2150 FR14/IP21 2806x2275x605 2300<br />

NXC21505A5L0SSFA1A2+ODU+ICB+AMO+TUP 1100 1940 2910 1200 2150 FR14/IP54 2806x2405x605 2330<br />

+ODU (du/dt filter), +ICB (MCCB), +AMO (ICB motor operator), +TUP INCLUDED AS STANDARD *<br />

I(H) = nominal current for 150% overload requirement (at max. 40°C ambient temperature)<br />

I(L) = nominal current for 110% overload requirement (at max. 40°C ambient temperature)<br />

I(overload) = maximum 1 min/10 min overload current (high overload)<br />

Vacon NXC Options DESCRIPTION NOTE<br />

+ACH Cabinet heater 50 W 1 x 50 W, requires +TUP *<br />

+ACL Cabinet light Requires +TUP *<br />

+CIT Cabling Input Top Including +CIT/+COT (W:+400 mm)<br />

+DCM Analog meter + curr.trafo CT on L1<br />

+DVM Analog V-meter + sel.sw. For main voltages<br />

+GPL 100 mm base/plinth For basic drive **<br />

+OCM Common mode chokes To be put on motor cable<br />

+OSI Sine wave filter *** W: +2x800 mm<br />

* IF UNIT ORDERED WITHOUT CONTROL VOLTAGE TRANSFORMER (ATx), THIS OPTION REQUIRES EXTERNAL 230 V SUPPLY<br />

** NOTE THAT THE OPTIONS THAT AFFECTS ON THE WIDHT OF THE CABINET REQUIRES AN EXTRA +GPL (see NXC common options on page 87)<br />

***PLEASE CHECK THE AVAILABILITY FROM THE FACTORY<br />

Vacon NXC 380-500 V, 2150 A, EMC level T, air-cooled AC drive, 6-pulse supply<br />

The prices are the same as L level ones.<br />

Replace the L by T in the order typecode.<br />

SUBJECT TO CHANGE WITHOUT NOTICE<br />

Vacon Plc Runsorintie 7 65380 VAASA FINLAND tel.:+358-201-2121 fax: +358 (0)201 212 205 http://www.vacon.com 51


Vacon Plc<br />

AC drive<br />

VACON PLC<br />

Vacon NXC 380-500 V, 385 A, EMC level L, air-cooled AC drive, 12-pulse supply<br />

ORDER TYPE CODE MOTOR SHAFT POWER AND CURRENT SIZE/PROT. DIMENSIONS WEIGHT<br />

High overload Low overload FR/IP W x H x D<br />

P [kW] I(H) I(overload) P [kW] I(L) [mm] [kg]<br />

NXC03855A2L0TSFA1A2 160 300 450 200 385 FR10/IP21 606x2275x605 371<br />

NXC03855A5L0TSFA1A2 160 300 450 200 385 FR10/IP54 606x2405x605 381<br />

I(H) = nominal current for 150% overload requirement (at max. 40°C ambient temperature)<br />

I(L) = nominal current for 110% overload requirement (at max. 40°C ambient temperature)<br />

I(overload) = maximum 1 min/10 min overload current (high overload)<br />

Vacon NXC Options DESCRIPTION NOTE<br />

+ACH Cabinet heater 50 W 1 x 50 W, requires +TUP *<br />

+ACL Cabinet light Requires +TUP *<br />

+AMO ICB motor operator Including Open/Close push buttons on the door, requires +TUP *<br />

+CIT Cabling Input Top Including +CIT/+COT (W:+400 mm)<br />

+DCM Analog meter + curr.trafo CT on L1<br />

+DVM Analog V-meter + sel.sw. For main voltages<br />

+GPL 100 mm base/plinth For basic drive **<br />

+ICB Circuit breaker MCCB, not with IFU *<br />

+IFU aR fuses & base Not with ICB<br />

+OCM Common mode chokes To be put on motor cable<br />

+ODU du/dt filter Including +CIT/+COT (W:+400 mm) ***<br />

+OSI Sine wave filter W: +600 mm, Please check the availability from the factory<br />

* IF UNIT ORDERED WITHOUT CONTROL VOLTAGE TRANSFORMER (ATx), THIS OPTION REQUIRES EXTERNAL 230 V SUPPLY<br />

** NOTE THAT THE OPTIONS THAT AFFECTS ON THE WIDHT OF THE CABINET REQUIRES AN EXTRA +GPL (see NXC common options on page 87)<br />

*** FOR CORRECT ORIENTATION OF DU/DT TERMINALS PLEASE ORDER ALSO +COT IF REQUIRED<br />

Vacon NXC 380-500 V, 385 A, EMC level T, air-cooled AC drive, 12-pulse supply<br />

The prices are the same as L level ones.<br />

Replace the L by T in the order typecode.<br />

SUBJECT TO CHANGE WITHOUT NOTICE<br />

Vacon Plc Runsorintie 7 65380 VAASA FINLAND tel.:+358-201-2121 fax: +358 (0)201 212 205 http://www.vacon.com 52


Vacon Plc<br />

AC drive<br />

VACON PLC<br />

Vacon NXC 380-500 V, 460 A, EMC level L, air-cooled AC drive, 12-pulse supply<br />

ORDER TYPE CODE MOTOR SHAFT POWER AND CURRENT SIZE/PROT. DIMENSIONS WEIGHT<br />

High overload Low overload FR/IP W x H x D<br />

P [kW] I(H) I(overload) P [kW] I(L) [mm] [kg]<br />

NXC04605A2L0TSFA1A2 200 385 578 250 460 FR10/IP21 606x2275x605 403<br />

NXC04605A5L0TSFA1A2 200 385 578 250 460 FR10/IP54 606x2405x605 413<br />

I(H) = nominal current for 150% overload requirement (at max. 40°C ambient temperature)<br />

I(L) = nominal current for 110% overload requirement (at max. 40°C ambient temperature)<br />

I(overload) = maximum 1 min/10 min overload current (high overload)<br />

Vacon NXC Options DESCRIPTION NOTE<br />

+ACH Cabinet heater 50 W 1 x 50 W, requires +TUP *<br />

+ACL Cabinet light Requires +TUP *<br />

+AMO ICB motor operator Including Open/Close push buttons on the door, requires +TUP *<br />

+CIT Cabling Input Top Including +CIT/+COT (W:+400 mm)<br />

+DCM Analog meter + curr.trafo CT on L1<br />

+DVM Analog V-meter + sel.sw. For main voltages<br />

+GPL 100 mm base/plinth For basic drive **<br />

+ICB Circuit breaker MCCB, not with IFU *<br />

+IFU aR fuses & base Not with ICB<br />

+OCM Common mode chokes To be put on motor cable<br />

+ODU du/dt filter Including +CIT/+COT (W:+400 mm) ***<br />

+OSI Sine wave filter W: +600 mm, Please check the availability from the factory<br />

* IF UNIT ORDERED WITHOUT CONTROL VOLTAGE TRANSFORMER (ATx), THIS OPTION REQUIRES EXTERNAL 230 V SUPPLY<br />

** NOTE THAT THE OPTIONS THAT AFFECTS ON THE WIDHT OF THE CABINET REQUIRES AN EXTRA +GPL (see NXC common options on page 87)<br />

*** FOR CORRECT ORIENTATION OF DU/DT TERMINALS PLEASE ORDER ALSO +COT IF REQUIRED<br />

Vacon NXC 380-500 V, 460 A, EMC level T, air-cooled AC drive, 12-pulse supply<br />

The prices are the same as L level ones.<br />

Replace the L by T in the order typecode.<br />

SUBJECT TO CHANGE WITHOUT NOTICE<br />

Vacon Plc Runsorintie 7 65380 VAASA FINLAND tel.:+358-201-2121 fax: +358 (0)201 212 205 http://www.vacon.com 53


Vacon Plc<br />

AC drive<br />

VACON PLC<br />

Vacon NXC 380-500 V, 520 A, EMC level L, air-cooled AC drive, 12-pulse supply<br />

ORDER TYPE CODE MOTOR SHAFT POWER AND CURRENT SIZE/PROT. DIMENSIONS WEIGHT<br />

High overload Low overload FR/IP W x H x D<br />

P [kW] I(H) I(overload) P [kW] I(L) [mm] [kg]<br />

NXC05205A2L0TSFA1A2 250 460 690 250 520 FR10/IP21 606x2275x605 403<br />

NXC05205A5L0TSFA1A2 250 460 690 250 520 FR10/IP54 606x2405x605 413<br />

I(H) = nominal current for 150% overload requirement (at max. 40°C ambient temperature)<br />

I(L) = nominal current for 110% overload requirement (at max. 40°C ambient temperature)<br />

I(overload) = maximum 1 min/10 min overload current (high overload)<br />

Vacon NXC Options DESCRIPTION NOTE<br />

+ACH Cabinet heater 50 W 1 x 50 W, requires +TUP *<br />

+ACL Cabinet light Requires +TUP *<br />

+AMO ICB motor operator Including Open/Close push buttons on the door, requires +TUP *<br />

+CIT Cabling Input Top Including +CIT/+COT (W:+400 mm)<br />

+DCM Analog meter + curr.trafo CT on L1<br />

+DVM Analog V-meter + sel.sw. For main voltages<br />

+GPL 100 mm base/plinth For basic drive **<br />

+ICB Circuit breaker MCCB, not with IFU *<br />

+IFU aR fuses & base Not with ICB<br />

+OCM Common mode chokes To be put on motor cable<br />

+ODU du/dt filter Including +CIT/+COT (W:+400 mm) ***<br />

+OSI Sine wave filter W: +600 mm, Please check the availability from the factory<br />

* IF UNIT ORDERED WITHOUT CONTROL VOLTAGE TRANSFORMER (ATx), THIS OPTION REQUIRES EXTERNAL 230 V SUPPLY<br />

** NOTE THAT THE OPTIONS THAT AFFECTS ON THE WIDHT OF THE CABINET REQUIRES AN EXTRA +GPL (see NXC common options on page 87)<br />

*** FOR CORRECT ORIENTATION OF DU/DT TERMINALS PLEASE ORDER ALSO +COT IF REQUIRED<br />

Vacon NXC 380-500 V, 520 A, EMC level T, air-cooled AC drive, 12-pulse supply<br />

The prices are the same as L level ones.<br />

Replace the L by T in the order typecode.<br />

SUBJECT TO CHANGE WITHOUT NOTICE<br />

Vacon Plc Runsorintie 7 65380 VAASA FINLAND tel.:+358-201-2121 fax: +358 (0)201 212 205 http://www.vacon.com 54


Vacon Plc<br />

AC drive<br />

VACON PLC<br />

Vacon NXC 380-500 V, 590 A, EMC level L, air-cooled AC drive, 12-pulse supply<br />

ORDER TYPE CODE MOTOR SHAFT POWER AND CURRENT SIZE/PROT. DIMENSIONS WEIGHT<br />

High overload Low overload FR/IP W x H x D<br />

P [kW] I(H) I(overload) P [kW] I(L) [mm] [kg]<br />

NXC05905A2L0TSFA1A2 250 520 780 315 590 FR11/IP21 806x2275x605 577<br />

NXC05905A5L0TSFA1A2 250 520 780 315 590 FR11/IP54 806x2405x605 590<br />

I(H) = nominal current for 150% overload requirement (at max. 40°C ambient temperature)<br />

I(L) = nominal current for 110% overload requirement (at max. 40°C ambient temperature)<br />

I(overload) = maximum 1 min/10 min overload current (high overload)<br />

Vacon NXC Options DESCRIPTION NOTE<br />

+ACH Cabinet heater 50 W 1 x 50 W, requires +TUP *<br />

+ACL Cabinet light Requires +TUP *<br />

+AMO ICB motor operator Including Open/Close push buttons on the door, requires +TUP *<br />

+CIT Cabling Input Top Including +CIT/+COT (W:+400 mm)<br />

+DCM Analog meter + curr.trafo CT on L1<br />

+DVM Analog V-meter + sel.sw. For main voltages<br />

+GPL 100 mm base/plinth For basic drive **<br />

+ICB Circuit breaker MCCB, not with +ILS, +IFU, +IFD or +ICO *<br />

+ICO Contactor AC-1 Requires +TUP *<br />

+IFD Fuse switch + aR fuses Not with +ILS, +IFU or +ICB<br />

+IFU aR fuses & base Not with +ILS, +ICB or +IFD<br />

+ILS Load switch Not with +IFU, +ICB or +IFD<br />

+OCM Common mode chokes To be put on motor cable<br />

+ODU du/dt filter Including +CIT/+COT (W:+400 mm) ***<br />

+OSI Sine wave filter W: +800 mm, Please check the availability from the factory<br />

* IF UNIT ORDERED WITHOUT CONTROL VOLTAGE TRANSFORMER (ATx), THIS OPTION REQUIRES EXTERNAL 230 V SUPPLY<br />

** NOTE THAT THE OPTIONS THAT AFFECTS ON THE WIDHT OF THE CABINET REQUIRES AN EXTRA +GPL (see NXC common options on page 87)<br />

*** FOR CORRECT ORIENTATION OF DU/DT TERMINALS PLEASE ORDER ALSO +COT IF REQUIRED<br />

Vacon NXC 380-500 V, 590 A, EMC level T, air-cooled AC drive, 12-pulse supply<br />

The prices are the same as L level ones.<br />

Replace the L by T in the order typecode.<br />

SUBJECT TO CHANGE WITHOUT NOTICE<br />

Vacon Plc Runsorintie 7 65380 VAASA FINLAND tel.:+358-201-2121 fax: +358 (0)201 212 205 http://www.vacon.com 55


Vacon Plc<br />

AC drive<br />

VACON PLC<br />

Vacon NXC 380-500 V, 650 A, EMC level L, air-cooled AC drive, 12-pulse supply<br />

ORDER TYPE CODE MOTOR SHAFT POWER AND CURRENT SIZE/PROT. DIMENSIONS WEIGHT<br />

High overload Low overload FR/IP W x H x D<br />

P [kW] I(H) I(overload) P [kW] I(L) [mm] [kg]<br />

NXC06505A2L0TSFA1A2 315 590 885 355 650 FR11/IP21 806x2275x605 577<br />

NXC06505A5L0TSFA1A2 315 590 885 355 650 FR11/IP54 806x2405x605 590<br />

I(H) = nominal current for 150% overload requirement (at max. 40°C ambient temperature)<br />

I(L) = nominal current for 110% overload requirement (at max. 40°C ambient temperature)<br />

I(overload) = maximum 1 min/10 min overload current (high overload)<br />

Vacon NXC Options DESCRIPTION NOTE<br />

+ACH Cabinet heater 50 W 1 x 50 W, requires +TUP *<br />

+ACL Cabinet light Requires +TUP *<br />

+AMO ICB motor operator Including Open/Close push buttons on the door, requires +TUP *<br />

+CIT Cabling Input Top Including +CIT/+COT (W:+400 mm)<br />

+DCM Analog meter + curr.trafo CT on L1<br />

+DVM Analog V-meter + sel.sw. For main voltages<br />

+GPL 100 mm base/plinth For basic drive **<br />

+ICB Circuit breaker MCCB, not with +ILS, +IFU, +IFD or +ICO *<br />

+ICO Contactor AC-1 Requires +TUP *<br />

+IFD Fuse switch + aR fuses Not with +ILS, +IFU or +ICB<br />

+IFU aR fuses & base Not with +ILS, +ICB or +IFD<br />

+ILS Load switch Not with +IFU, +ICB or +IFD<br />

+OCM Common mode chokes To be put on motor cable<br />

+ODU du/dt filter Including +CIT/+COT (W:+400 mm) ***<br />

+OSI Sine wave filter W: +800 mm, Please check the availability from the factory<br />

* IF UNIT ORDERED WITHOUT CONTROL VOLTAGE TRANSFORMER (ATx), THIS OPTION REQUIRES EXTERNAL 230 V SUPPLY<br />

** NOTE THAT THE OPTIONS THAT AFFECTS ON THE WIDHT OF THE CABINET REQUIRES AN EXTRA +GPL (see NXC common options on page 87)<br />

*** FOR CORRECT ORIENTATION OF DU/DT TERMINALS PLEASE ORDER ALSO +COT IF REQUIRED<br />

Vacon NXC 380-500 V, 650 A, EMC level T, air-cooled AC drive, 12-pulse supply<br />

The prices are the same as L level ones.<br />

Replace the L by T in the order typecode.<br />

SUBJECT TO CHANGE WITHOUT NOTICE<br />

Vacon Plc Runsorintie 7 65380 VAASA FINLAND tel.:+358-201-2121 fax: +358 (0)201 212 205 http://www.vacon.com 56


Vacon Plc<br />

AC drive<br />

VACON PLC<br />

Vacon NXC 380-500 V, 730 A, EMC level L, air-cooled AC drive, 12-pulse supply<br />

ORDER TYPE CODE MOTOR SHAFT POWER AND CURRENT SIZE/PROT. DIMENSIONS WEIGHT<br />

High overload Low overload FR/IP W x H x D<br />

P [kW] I(H) I(overload) P [kW] I(L) [mm] [kg]<br />

NXC07305A2L0TSFA1A2 355 650 975 400 730 FR11/IP21 806x2275x605 577<br />

NXC07305A5L0TSFA1A2 355 650 975 400 730 FR11/IP54 806x2445x605 590<br />

I(H) = nominal current for 150% overload requirement (at max. 40°C ambient temperature)<br />

I(L) = nominal current for 110% overload requirement (at max. 40°C ambient temperature)<br />

Vacon NXC Options DESCRIPTION NOTE<br />

+ACH Cabinet heater 50 W 1 x 50 W, requires +TUP *<br />

+ACL Cabinet light Requires +TUP *<br />

+AMO ICB motor operator Including Open/Close push buttons on the door, requires +TUP *<br />

+CIT Cabling Input Top Including +CIT/+COT (W:+400 mm)<br />

+DCM Analog meter + curr.trafo CT on L1<br />

+DVM Analog V-meter + sel.sw. For main voltages<br />

+GPL 100 mm base/plinth For basic drive **<br />

+ICB Circuit breaker MCCB, not with +ILS, +IFU, +IFD or +ICO, requires +TUP *<br />

+ICO Contactor AC-1 Requires +TUP *<br />

+IFD Fuse switch + aR fuses Not with +ILS, +IFU or +ICB<br />

+IFU aR fuses & base Not with +ILS, +ICB or +IFD<br />

+ILS Load switch Not with +IFU, +ICB or +IFD<br />

+OCM Common mode chokes To be put on motor cable<br />

+ODU du/dt filter Including +CIT/+COT (W:+400 mm) ***<br />

+OSI Sine wave filter W: +800 mm, Please check the availability from the factory<br />

* IF UNIT ORDERED WITHOUT CONTROL VOLTAGE TRANSFORMER (ATx), THIS OPTION REQUIRES EXTERNAL 230 V SUPPLY<br />

** NOTE THAT THE OPTIONS THAT AFFECTS ON THE WIDHT OF THE CABINET REQUIRES AN EXTRA +GPL (see NXC common options on page 87)<br />

*** FOR CORRECT ORIENTATION OF DU/DT TERMINALS PLEASE ORDER ALSO +COT IF REQUIRED<br />

Vacon NXC 380-500 V, 730 A, EMC level T, air-cooled AC drive, 12-pulse supply<br />

The prices are the same as L level ones.<br />

Replace the L by T in the order typecode.<br />

SUBJECT TO CHANGE WITHOUT NOTICE<br />

Vacon Plc Runsorintie 7 65380 VAASA FINLAND tel.:+358-201-2121 fax: +358 (0)201 212 205 http://www.vacon.com 57


Vacon Plc<br />

AC drive<br />

VACON PLC<br />

Vacon NXC 380-500 V, 820 A, EMC level L, air-cooled AC drive, 12-pulse supply<br />

ORDER TYPE CODE MOTOR SHAFT POWER AND CURRENT SIZE/PROT. DIMENSIONS WEIGHT<br />

High overload Low overload FR/IP W x H x D<br />

P [kW] I(H) I(overload) P [kW] I(L) [mm] [kg]<br />

NXC08205A2L0TSFA1A2 400 730 1095 450 820 FR12/IP21 1206x2275x605 810<br />

NXC08205A5L0TSFA1A2 400 730 1095 450 820 FR12/IP54 1206x2405x605 830<br />

I(H) = nominal current for 150% overload requirement (at max. 40°C ambient temperature)<br />

I(L) = nominal current for 110% overload requirement (at max. 40°C ambient temperature)<br />

I(overload) = maximum 1 min/10 min overload current (high overload)<br />

Vacon NXC Options DESCRIPTION NOTE<br />

+ACH Cabinet heater 50 W 1 x 50 W, requires +TUP *<br />

+ACL Cabinet light Requires +TUP *<br />

+CIT Cabling Input Top Including +CIT/+COT (W:+400 mm)<br />

+DCM Analog meter + curr.trafo CT on L1<br />

+DVM Analog V-meter + sel.sw. For main voltages<br />

+GPL 100 mm base/plinth For basic drive **<br />

+ICB Circuit breaker, including +AMO MCCB, not with +ILS, +IFU, +IFD or +ICO, requires +TUP *<br />

+ICO Contactor AC-1 Requires +TUP *<br />

+IFD Fuse switch + aR fuses Not with +ILS, +IFU or +ICB<br />

+IFU aR fuses & base Not with +ILS, +ICB or +IFD<br />

+ILS Load switch Not with +IFU, +ICB or +IFD<br />

+OCM Common mode chokes To be put on motor cable<br />

+ODU du/dt filter Including +CIT/+COT (W:+400 mm) **<br />

+OSI Sine wave filter W: +2x600 mm, Please check the availability from the factory<br />

* IF UNIT ORDERED WITHOUT CONTROL VOLTAGE TRANSFORMER (ATx), THIS OPTION REQUIRES EXTERNAL 230 V SUPPLY<br />

** NOTE THAT THE OPTIONS THAT AFFECTS ON THE WIDHT OF THE CABINET REQUIRES AN EXTRA +GPL (see NXC common options on page 87)<br />

*** FOR CORRECT ORIENTATION OF DU/DT TERMINALS PLEASE ORDER ALSO +COT IF REQUIRED<br />

Vacon NXC 380-500 V, 820 A, EMC level T, air-cooled AC drive, 12-pulse supply<br />

The prices are the same as L level ones.<br />

Replace the L by T in the order typecode.<br />

SUBJECT TO CHANGE WITHOUT NOTICE<br />

Vacon Plc Runsorintie 7 65380 VAASA FINLAND tel.:+358-201-2121 fax: +358 (0)201 212 205 http://www.vacon.com 58


Vacon Plc<br />

AC drive<br />

VACON PLC<br />

Vacon NXC 380-500 V, 920 A, EMC level L, air-cooled AC drive, 12-pulse supply<br />

ORDER TYPE CODE MOTOR SHAFT POWER AND CURRENT SIZE/PROT. DIMENSIONS WEIGHT<br />

High overload Low overload FR/IP W x H x D<br />

P [kW] I(H) I(overload) P [kW] I(L) [mm] [kg]<br />

NXC09205A2L0TSFA1A2 450 820 1230 500 920 FR12/IP21 1206x2275x605 810<br />

NXC09205A5L0TSFA1A2 450 820 1230 500 920 FR12/IP54 1206x2405x605 830<br />

I(H) = nominal current for 150% overload requirement (at max. 40°C ambient temperature)<br />

I(L) = nominal current for 110% overload requirement (at max. 40°C ambient temperature)<br />

I(overload) = maximum 1 min/10 min overload current (high overload)<br />

Vacon NXC Options DESCRIPTION NOTE<br />

+ACH Cabinet heater 50 W 1 x 50 W, requires +TUP *<br />

+ACL Cabinet light Requires +TUP *<br />

+CIT Cabling Input Top Including +CIT/+COT (W:+400 mm)<br />

+DCM Analog meter + curr.trafo CT on L1<br />

+DVM Analog V-meter + sel.sw. For main voltages<br />

+GPL 100 mm base/plinth For basic drive **<br />

+ICB Circuit breaker, including +AMO MCCB, not with +ILS, +IFU, +IFD or +ICO, requires +TUP *<br />

+ICO Contactor AC-1 Requires +TUP *<br />

+IFD Fuse switch + aR fuses Not with +ILS, +IFU or +ICB<br />

+IFU aR fuses & base Not with +ILS, +ICB or +IFD<br />

+ILS Load switch Not with +IFU, +ICB or +IFD<br />

+OCM Common mode chokes To be put on motor cable<br />

+ODU du/dt filter Including +CIT/+COT (W:+400 mm) ***<br />

+OSI Sine wave filter W: +2x600 mm, Please check the availability from the factory<br />

* IF UNIT ORDERED WITHOUT CONTROL VOLTAGE TRANSFORMER (ATx), THIS OPTION REQUIRES EXTERNAL 230 V SUPPLY<br />

** NOTE THAT THE OPTIONS THAT AFFECTS ON THE WIDHT OF THE CABINET REQUIRES AN EXTRA +GPL (see NXC common options on page 87)<br />

*** FOR CORRECT ORIENTATION OF DU/DT TERMINALS PLEASE ORDER ALSO +COT IF REQUIRED<br />

Vacon NXC 380-500 V, 920 A, EMC level T, air-cooled AC drive, 12-pulse supply<br />

The prices are the same as L level ones.<br />

Replace the L by T in the order typecode.<br />

SUBJECT TO CHANGE WITHOUT NOTICE<br />

Vacon Plc Runsorintie 7 65380 VAASA FINLAND tel.:+358-201-2121 fax: +358 (0)201 212 205 http://www.vacon.com 59


Vacon Plc<br />

AC drive<br />

VACON PLC<br />

Vacon NXC 380-500 V, 1030 A, EMC level L, air-cooled AC drive, 12-pulse supply<br />

ORDER TYPE CODE MOTOR SHAFT POWER AND CURRENT SIZE/PROT. DIMENSIONS WEIGHT<br />

High overload Low overload FR/IP W x H x D<br />

P [kW] I(H) I(overload) P [kW] I(L) [mm] [kg]<br />

NXC10305A2L0TSFA1A2 500 920 1380 560 1030 FR12/IP21 1206x2275x605 810<br />

NXC10305A5L0TSFA1A2 500 920 1380 560 1030 FR12/IP54 1206x2405x605 830<br />

I(H) = nominal current for 150% overload requirement (at max. 40°C ambient temperature)<br />

I(L) = nominal current for 110% overload requirement (at max. 40°C ambient temperature)<br />

I(overload) = maximum 1 min/10 min overload current (high overload)<br />

Vacon NXC Options DESCRIPTION NOTE<br />

+ACH Cabinet heater 50 W 1 x 50 W, requires +TUP *<br />

+ACL Cabinet light Requires +TUP *<br />

+CIT Cabling Input Top Including +CIT/+COT (W:+400 mm)<br />

+DCM Analog meter + curr.trafo CT on L1<br />

+DVM Analog V-meter + sel.sw. For main voltages<br />

+GPL 100 mm base/plinth For basic drive **<br />

+ICB Circuit breaker, including +AMO MCCB, not with +ILS, +IFU, +IFD or +ICO, requires +TUP *<br />

+ICO Contactor AC-1 Requires +TUP *<br />

+IFD Fuse switch + aR fuses Not with +ILS, +IFU or +ICB<br />

+IFU aR fuses & base Not with +ILS, +ICB or +IFD<br />

+ILS Load switch Not with +IFU, +ICB or +IFD<br />

+OCM Common mode chokes To be put on motor cable<br />

+ODU du/dt filter Including +CIT/+COT (W:+400 mm) **<br />

+OSI Sine wave filter W: +2x600 mm, Please check the availability from the factory<br />

* IF UNIT ORDERED WITHOUT CONTROL VOLTAGE TRANSFORMER (ATx), THIS OPTION REQUIRES EXTERNAL 230 V SUPPLY<br />

** NOTE THAT THE OPTIONS THAT AFFECTS ON THE WIDHT OF THE CABINET REQUIRES AN EXTRA +GPL (see NXC common options on page 87)<br />

*** FOR CORRECT ORIENTATION OF DU/DT TERMINALS PLEASE ORDER ALSO +COT IF REQUIRED<br />

Vacon NXC 380-500 V, 1030 A, EMC level T, air-cooled AC drive, 12-pulse supply<br />

The prices are the same as L level ones.<br />

Replace the L by T in the order typecode.<br />

SUBJECT TO CHANGE WITHOUT NOTICE<br />

Vacon Plc Runsorintie 7 65380 VAASA FINLAND tel.:+358-201-2121 fax: +358 (0)201 212 205 http://www.vacon.com 60


Vacon Plc<br />

AC drive<br />

VACON PLC<br />

Vacon NXC 380-500 V, 1150 A, EMC level L, air-cooled AC drive, 12-pulse supply<br />

ORDER TYPE CODE MOTOR SHAFT POWER AND CURRENT SIZE/PROT. DIMENSIONS WEIGHT<br />

High overload Low overload FR/IP W x H x D<br />

P [kW] I(H) I(overload) P [kW] I(L) [mm] [kg]<br />

NXC11505A2L0TSFA1A2 +ICB +AMO +TUP 560 1030 1545 630 1150 FR13/IP21 1406x2275x605 1050<br />

NXC11505A5L0TSFA1A2 +ICB +AMO +TUP 560 1030 1545 630 1150 FR13/IP54 1406x2405x605 1060<br />

+ICB (MCCB), +AMO (ICB motor operator), +TUP INCLUDED AS STANDARD *<br />

I(H) = nominal current for 150% overload requirement (at max. 40°C ambient temperature)<br />

I(L) = nominal current for 110% overload requirement (at max. 40°C ambient temperature)<br />

I(overload) = maximum 1 min/10 min overload current (high overload)<br />

Vacon NXC Options DESCRIPTION NOTE<br />

+ACH Cabinet heater 50 W 1 x 50 W, requires +TUP *<br />

+ACL Cabinet light Requires +TUP *<br />

+CIT Cabling Input Top Including +CIT/+COT (W:+400 mm)<br />

+DCM Analog meter + curr.trafo CT on L1<br />

+DVM Analog V-meter + sel.sw. For main voltages<br />

+GPL 100 mm base/plinth For basic drive **<br />

+OCM Common mode chokes To be put on motor cable<br />

+ODU<br />

du/dt filter<br />

+OSI Sine wave filter W: +800 mm, Please check the availability from the factory<br />

* IF UNIT ORDERED WITHOUT CONTROL VOLTAGE TRANSFORMER (ATx), THIS OPTION REQUIRES EXTERNAL 230 V SUPPLY<br />

** NOTE THAT THE OPTIONS THAT AFFECTS ON THE WIDHT OF THE CABINET REQUIRES AN EXTRA +GPL (see NXC common options on page 87)<br />

Vacon NXC 380-500 V, 1150 A, EMC level T, air-cooled AC drive, 12-pulse supply<br />

The prices are the same as L level ones.<br />

Replace the L by T in the order typecode.<br />

SUBJECT TO CHANGE WITHOUT NOTICE<br />

Vacon Plc Runsorintie 7 65380 VAASA FINLAND tel.:+358-201-2121 fax: +358 (0)201 212 205 http://www.vacon.com 61


Vacon Plc<br />

AC drive<br />

VACON PLC<br />

Vacon NXC 380-500 V, 1300 A, EMC level L, air-cooled AC drive, 12-pulse supply<br />

ORDER TYPE CODE MOTOR SHAFT POWER AND CURRENT SIZE/PROT. DIMENSIONS WEIGHT<br />

High overload Low overload FR/IP W x H x D<br />

P [kW] I(H) I(overload) P [kW] I(L) [mm] [kg]<br />

NXC13005A2L0TSFA1A2 +ICB +AMO +TUP 630 1150 1725 710 1300 FR13/IP21 2006x2275x605 1700<br />

NXC13005A5L0TSFA1A2 +ICB +AMO +TUP 630 1150 1725 710 1300 FR13/IP54 2006x2405x605 1710<br />

+ICB (MCCB), +AMO (ICB motor operator), +TUP INCLUDED AS STANDARD *<br />

I(H) = nominal current for 150% overload requirement (at max. 40°C ambient temperature)<br />

I(L) = nominal current for 110% overload requirement (at max. 40°C ambient temperature)<br />

I(overload) = maximum 1 min/10 min overload current (high overload)<br />

Vacon NXC Options DESCRIPTION NOTE<br />

+ACH Cabinet heater 50 W 1 x 50 W, requires +TUP *<br />

+ACL Cabinet light Requires +TUP *<br />

+CIT Cabling Input Top Including +CIT/+COT (W:+400 mm)<br />

+DCM Analog meter + curr.trafo CT on L1<br />

+DVM Analog V-meter + sel.sw. For main voltages<br />

+GPL 100 mm base/plinth For basic drive **<br />

+OCM Common mode chokes To be put on motor cable<br />

+ODU<br />

du/dt filter<br />

+OSI Sine wave filter W: +800 mm, Please check the availability from the factory<br />

* IF UNIT ORDERED WITHOUT CONTROL VOLTAGE TRANSFORMER (ATx), THIS OPTION REQUIRES EXTERNAL 230 V SUPPLY<br />

** NOTE THAT THE OPTIONS THAT AFFECTS ON THE WIDHT OF THE CABINET REQUIRES AN EXTRA +GPL (see NXC common options on page 87)<br />

Vacon NXC 380-500 V, 1300 A, EMC level T, air-cooled AC drive, 12-pulse supply<br />

The prices are the same as L level ones.<br />

Replace the L by T in the order typecode.<br />

SUBJECT TO CHANGE WITHOUT NOTICE<br />

Vacon Plc Runsorintie 7 65380 VAASA FINLAND tel.:+358-201-2121 fax: +358 (0)201 212 205 http://www.vacon.com 62


Vacon Plc<br />

AC drive<br />

VACON PLC<br />

Vacon NXC 380-500 V, 1450 A, EMC level L, air-cooled AC drive, 12-pulse supply<br />

ORDER TYPE CODE MOTOR SHAFT POWER AND CURRENT SIZE/PROT. DIMENSIONS WEIGHT<br />

High overload Low overload FR/IP W x H x D<br />

P [kW] I(H) I(overload) P [kW] I(L) [mm] [kg]<br />

NXC14505A2L0TSFA1A2 +ICB +AMO +TUP 710 1300 1950 800 1450 FR13/IP21 2006x2275x605 1700<br />

NXC14505A5L0TSFA1A2 +ICB +AMO +TUP 710 1300 1950 800 1450 FR13/IP54 2006x2405x605 1710<br />

+ICB (MCCB), +AMO (ICB motor operator), +TUP INCLUDED AS STANDARD *<br />

I(H) = nominal current for 150% overload requirement (at max. 40°C ambient temperature)<br />

I(L) = nominal current for 110% overload requirement (at max. 40°C ambient temperature)<br />

I(overload) = maximum 1 min/10 min overload current (high overload)<br />

Vacon NXC Options DESCRIPTION NOTE<br />

+ACH Cabinet heater 50 W 1 x 50 W, requires +TUP *<br />

+ACL Cabinet light Requires +TUP *<br />

+CIT Cabling Input Top Including +CIT/+COT (W:+400 mm)<br />

+DCM Analog meter + curr.trafo CT on L1<br />

+DVM Analog V-meter + sel.sw. For main voltages<br />

+GPL 100 mm base/plinth For basic drive **<br />

+OCM Common mode chokes To be put on motor cable<br />

+ODU<br />

du/dt filter<br />

+OSI Sine wave filter W: +800 mm, Please check the availability from the factory<br />

* IF UNIT ORDERED WITHOUT CONTROL VOLTAGE TRANSFORMER (ATx), THIS OPTION REQUIRES EXTERNAL 230 V SUPPLY<br />

** NOTE THAT THE OPTIONS THAT AFFECTS ON THE WIDHT OF THE CABINET REQUIRES AN EXTRA +GPL (see NXC common options on page 87)<br />

Vacon NXC 380-500 V, 1450 A, EMC level T, air-cooled AC drive, 12-pulse supply<br />

The prices are the same as L level ones.<br />

Replace the L by T in the order typecode.<br />

SUBJECT TO CHANGE WITHOUT NOTICE<br />

Vacon Plc Runsorintie 7 65380 VAASA FINLAND tel.:+358-201-2121 fax: +358 (0)201 212 205 http://www.vacon.com 63


Vacon Plc<br />

AC drive<br />

VACON PLC<br />

Vacon NXC 380-500 V, 1770 A, EMC level L, air-cooled AC drive, 12-pulse supply<br />

ORDER TYPE CODE MOTOR SHAFT POWER AND CURRENT SIZE/PROT. DIMENSIONS WEIGHT<br />

High overload Low overload FR/IP W x H x D<br />

P [kW] I(H) I(overload) P [kW] I(L) [mm] [kg]<br />

NXC17705A2L0TSFA1A2+ODU+ICB+AMO+TUP 900 1600 2400 1000 1770 FR14/IP21 2806x2275x605 2250<br />

NXC17705A5L0TSFA1A2+ODU+ICB+AMO+TUP 900 1600 2400 1000 1770 FR14/IP54 2806x2405x605 2280<br />

+ODU (du/dt filter), +ICB (MCCB), +AMO (ICB motor operator), +TUP INCLUDED AS STANDARD *<br />

I(H) = nominal current for 150% overload requirement (at max. 40°C ambient temperature)<br />

I(L) = nominal current for 110% overload requirement (at max. 40°C ambient temperature)<br />

I(overload) = maximum 1 min/10 min overload current (high overload)<br />

Vacon NXC Options DESCRIPTION NOTE<br />

+ACH Cabinet heater 50 W 1 x 50 W, requires +TUP *<br />

+ACL Cabinet light Requires +TUP *<br />

+CIT Cabling Input Top Including +CIT/+COT (W:+400 mm)<br />

+DCM Analog meter + curr.trafo CT on L1<br />

+DVM Analog V-meter + sel.sw. For main voltages<br />

+GPL 100 mm base/plinth For basic drive **<br />

+OCM Common mode chokes To be put on motor cable<br />

+OSI Sine wave filter *** W: +2x800 mm<br />

* IF UNIT ORDERED WITHOUT CONTROL VOLTAGE TRANSFORMER (ATx), THIS OPTION REQUIRES EXTERNAL 230 V SUPPLY<br />

** NOTE THAT THE OPTIONS THAT AFFECTS ON THE WIDHT OF THE CABINET REQUIRES AN EXTRA +GPL (see NXC common options on page 87)<br />

***PLEASE CHECK THE AVAILABILITY FROM THE FACTORY<br />

Vacon NXC 380-500 V, 1770 A, EMC level T, air-cooled AC drive, 6-pulse supply<br />

The prices are the same as L level ones.<br />

Replace the L by T in the order typecode.<br />

SUBJECT TO CHANGE WITHOUT NOTICE<br />

Vacon Plc Runsorintie 7 65380 VAASA FINLAND tel.:+358-201-2121 fax: +358 (0)201 212 205 http://www.vacon.com 64


Vacon Plc<br />

AC drive<br />

VACON PLC<br />

Vacon NXC 380-500 V, 2150 A, EMC level L, air-cooled AC drive, 12-pulse supply<br />

ORDER TYPE CODE MOTOR SHAFT POWER AND CURRENT SIZE/PROT. DIMENSIONS WEIGHT<br />

High overload Low overload FR/IP W x H x D<br />

P [kW] I(H) I(overload) P [kW] I(L) [mm] [kg]<br />

NXC21505A2L0TSFA1A2+ODU+ICB+AMO+TUP 1100 1940 2910 1200 2150 FR14/IP21 2806x2275x605 2300<br />

NXC21505A5L0TSFA1A2+ODU+ICB+AMO+TUP 1100 1940 2910 1200 2150 FR14/IP54 2806x2405x605 2330<br />

+ODU (du/dt filter), +ICB (MCCB), +AMO (ICB motor operator), +TUP INCLUDED AS STANDARD *<br />

I(H) = nominal current for 150% overload requirement (at max. 40°C ambient temperature)<br />

I(L) = nominal current for 110% overload requirement (at max. 40°C ambient temperature)<br />

I(overload) = maximum 1 min/10 min overload current (high overload)<br />

Vacon NXC Options DESCRIPTION NOTE<br />

+ACH Cabinet heater 50 W 1 x 50 W, requires +TUP *<br />

+ACL Cabinet light Requires +TUP *<br />

+CIT Cabling Input Top Including +CIT/+COT (W:+400 mm)<br />

+DCM Analog meter + curr.trafo CT on L1<br />

+DVM Analog V-meter + sel.sw. For main voltages<br />

+GPL 100 mm base/plinth For basic drive **<br />

+OCM Common mode chokes To be put on motor cable<br />

+OSI Sine wave filter *** W: +2x800 mm<br />

* IF UNIT ORDERED WITHOUT CONTROL VOLTAGE TRANSFORMER (ATx), THIS OPTION REQUIRES EXTERNAL 230 V SUPPLY<br />

** NOTE THAT THE OPTIONS THAT AFFECTS ON THE WIDHT OF THE CABINET REQUIRES AN EXTRA +GPL (see NXC common options on page 87)<br />

***PLEASE CHECK THE AVAILABILITY FROM THE FACTORY<br />

Vacon NXC 380-500 V, 2150 A, EMC level T, air-cooled AC drive, 12-pulse supply<br />

The prices are the same as L level ones.<br />

Replace the L by T in the order typecode.<br />

SUBJECT TO CHANGE WITHOUT NOTICE<br />

Vacon Plc Runsorintie 7 65380 VAASA FINLAND tel.:+358-201-2121 fax: +358 (0)201 212 205 http://www.vacon.com 65


Vacon Plc<br />

AC drive<br />

VACON PLC<br />

Vacon NXC 525-690 V, 125 A, EMC level L, air-cooled AC drive, 6-pulse supply<br />

ORDER TYPE CODE MOTOR SHAFT POWER AND CURRENT SIZE/PROT. DIMENSIONS WEIGHT<br />

High overload Low overload FR/IP W x H x D<br />

P [kW] I(H) I(overload) P [kW] I(L) [mm] [kg]<br />

NXC01256A2L0SSFA1A2 90 100 150 110 125 FR9/IP21 606x2275x605 308<br />

NXC01256A5L0SSFA1A2 90 100 150 110 125 FR9/IP54 606x2405x605 318<br />

I(H) = nominal current for 150% overload requirement (at max. 50°C ambient temperature)<br />

I(L) = nominal current for 110% overload requirement (at max. 40°C ambient temperature)<br />

I(overload) = maximum 1 min/10 min overload current (high overload)<br />

Vacon NXC Options DESCRIPTION NOTE<br />

+ACH Cabinet heater 50 W 1 x 50 W, requires +TUP *<br />

+ACL Cabinet light Requires +TUP *<br />

+AMO ICB motor operator Including Open/Close push buttons on the door, requires +TUP *<br />

+CIT Cabling Input Top Including +CIT/+COT (W:+400 mm)<br />

+DCM Analog meter + curr.trafo CT on L1<br />

+DVM Analog V-meter + sel.sw. For main voltages<br />

+GPL 100 mm base/plinth For basic drive **<br />

+ICB Circuit breaker MCCB, not with +ILS, +IFU, +IFD or +ICO<br />

+ICO Contactor AC-1 Requires +TUP *<br />

+IFD Fuse switch + aR fuses Not with +ILS, +IFU or +ICB<br />

+IFU aR fuses & base Not with +ILS, +ICB or +IFD<br />

+ILS Load switch Not with +IFU, +ICB or +IFD<br />

+MDC Terminals for DC connect. DC-connection / additional dc/brake chopper terminals<br />

+OCM Common mode chokes To be put on motor cable<br />

+ODU<br />

du/dt filter<br />

* IF UNIT ORDERED WITHOUT CONTROL VOLTAGE TRANSFORMER (ATx), THIS OPTION REQUIRES EXTERNAL 230 V SUPPLY<br />

** NOTE THAT THE OPTIONS THAT AFFECTS ON THE WIDHT OF THE CABINET REQUIRES AN EXTRA +GPL (see NXC common options on page 87)<br />

*** FOR CORRECT ORIENTATION OF DU/DT TERMINALS PLEASE ORDER ALSO +COT IF REQUIRED<br />

Vacon NXC 525-690 V, 125 A, EMC level T, air-cooled AC drive, 6-pulse supply<br />

The prices are the same as L level ones.<br />

Replace the L by T in the order typecode.<br />

SUBJECT TO CHANGE WITHOUT NOTICE<br />

Vacon Plc Runsorintie 7 65380 VAASA FINLAND tel.:+358-201-2121 fax: +358 (0)201 212 205 http://www.vacon.com 66


Vacon Plc<br />

AC drive<br />

VACON PLC<br />

Vacon NXC 525-690 V, 144 A, EMC level L, air-cooled AC drive, 6-pulse supply<br />

ORDER TYPE CODE MOTOR SHAFT POWER AND CURRENT SIZE/PROT. DIMENSIONS WEIGHT<br />

High overload Low overload FR/IP W x H x D<br />

P [kW] I(H) I(overload) P [kW] I(L) [mm] [kg]<br />

NXC01446A2L0SSFA1A2 110 125 188 132 144 FR9/IP21 606x2275x605 308<br />

NXC01446A5L0SSFA1A2 110 125 188 132 144 FR9/IP54 606x2405x605 318<br />

I(H) = nominal current for 150% overload requirement (at max. 50°C ambient temperature)<br />

I(L) = nominal current for 110% overload requirement (at max. 40°C ambient temperature)<br />

I(overload) = maximum 1 min/10 min overload current (high overload)<br />

Vacon NXC Options<br />

DESCRIPTION<br />

+ACH Cabinet heater 50 W 1 x 50 W, requires +TUP *<br />

+ACL Cabinet light Requires +TUP *<br />

+AMO ICB motor operator Including Open/Close push buttons on the door, requires +TUP *<br />

+CIT Cabling Input Top Including +CIT/+COT (W:+400 mm)<br />

+DCM Analog meter + curr.trafo CT on L1<br />

+DVM Analog V-meter + sel.sw. For main voltages<br />

+GPL 100 mm base/plinth For basic drive ***<br />

+ICB Circuit breaker MCCB, not with +ILS, +IFU, +IFD or +ICO<br />

+ICO Contactor AC-1 Requires +TUP *<br />

+IFD Fuse switch + aR fuses Not with +ILS, +IFU or +ICB<br />

+IFU aR fuses & base Not with +ILS, +ICB or +IFD<br />

+ILS Load switch Not with +IFU, +ICB or +IFD<br />

+MDC Terminals for DC connect. DC-connection / additional dc/brake chopper terminals<br />

+OCM Common mode chokes To be put on motor cable<br />

+ODU<br />

du/dt filter<br />

* IF UNIT ORDERED WITHOUT CONTROL VOLTAGE TRANSFORMER (ATx), THIS OPTION REQUIRES EXTERNAL 230 V SUPPLY<br />

** NOTE THAT THE OPTIONS THAT AFFECTS ON THE WIDHT OF THE CABINET REQUIRES AN EXTRA +GPL (see NXC common options on page 87)<br />

*** FOR CORRECT ORIENTATION OF DU/DT TERMINALS PLEASE ORDER ALSO +COT IF REQUIRED<br />

Vacon NXC 525-690 V, 144 A, EMC level T, air-cooled AC drive, 6-pulse supply<br />

The prices are the same as L level ones.<br />

Replace the L by T in the order typecode.<br />

SUBJECT TO CHANGE WITHOUT NOTICE<br />

Vacon Plc Runsorintie 7 65380 VAASA FINLAND tel.:+358-201-2121 fax: +358 (0)201 212 205 http://www.vacon.com 67


Vacon Plc<br />

AC drive<br />

VACON PLC<br />

Vacon NXC 525-690 V, 170 A, EMC level L, air-cooled AC drive, 6-pulse supply<br />

ORDER TYPE CODE MOTOR SHAFT POWER AND CURRENT SIZE/PROT. DIMENSIONS WEIGHT<br />

High overload Low overload FR/IP W x H x D<br />

P [kW] I(H) I(overload) P [kW] I(L) [mm] [kg]<br />

NXC01706A2L0SSFA1A2 132 144 216 160 170 FR9/IP21 606x2275x605 308<br />

NXC01706A5L0SSFA1A2 132 144 216 160 170 FR9/IP54 606x2405x605 318<br />

I(H) = nominal current for 150% overload requirement (at max. 50°C ambient temperature)<br />

I(L) = nominal current for 110% overload requirement (at max. 40°C ambient temperature)<br />

I(overload) = maximum 1 min/10 min overload current (high overload)<br />

Vacon NXC Options DESCRIPTION NOTE<br />

+ACH Cabinet heater 50 W 1 x 50 W, requires +TUP *<br />

+ACL Cabinet light MCCB, not with +ILS, +IFU, +IFD or +ICO<br />

+AMO ICB motor operator Including Open/Close push buttons on the door, requires +TUP *<br />

+CIT Cabling Input Top Including +CIT/+COT (W:+400 mm)<br />

+DCM Analog meter + curr.trafo Not with +ILS, +ICB or +IFD<br />

+DVM Analog V-meter + sel.sw. For main voltages<br />

+GPL 100 mm base/plinth For basic drive **<br />

+ICB Circuit breaker MCCB, not with +ILS, +IFU, +IFD or +ICO<br />

+ICO Contactor AC-1 Requires +TUP *<br />

+IFD Fuse switch + aR fuses Not with +ILS, +IFU or +ICB<br />

+IFU aR fuses & base Not with +ILS, +ICB or +IFD<br />

+ILS Load switch Not with +IFU, +ICB or +IFD<br />

+MDC Terminals for DC connect. DC-connection / additional dc/brake chopper terminals<br />

+OCM Common mode chokes To be put on motor cable<br />

+ODU<br />

du/dt filter<br />

* IF UNIT ORDERED WITHOUT CONTROL VOLTAGE TRANSFORMER (ATx), THIS OPTION REQUIRES EXTERNAL 230 V SUPPLY<br />

** NOTE THAT THE OPTIONS THAT AFFECTS ON THE WIDHT OF THE CABINET REQUIRES AN EXTRA +GPL (see NXC common options on page 87)<br />

*** FOR CORRECT ORIENTATION OF DU/DT TERMINALS PLEASE ORDER ALSO +COT IF REQUIRED<br />

Vacon NXC 525-690 V, 170 A, EMC level T, air-cooled AC drive, 6-pulse supply<br />

The prices are the same as L level ones.<br />

Replace the L by T in the order typecode.<br />

SUBJECT TO CHANGE WITHOUT NOTICE<br />

Vacon Plc Runsorintie 7 65380 VAASA FINLAND tel.:+358-201-2121 fax: +358 (0)201 212 205 http://www.vacon.com 68


Vacon Plc<br />

AC drive<br />

VACON PLC<br />

Vacon NXC 525-690 V, 208 A, EMC level L, air-cooled AC drive, 6-pulse supply<br />

ORDER TYPE CODE MOTOR SHAFT POWER AND CURRENT SIZE/PROT. DIMENSIONS WEIGHT<br />

High overload Low overload FR/IP W x H x D<br />

P [kW] I(H) I(overload) P [kW] I(L) [mm] [kg]<br />

NXC02086A2L0SSFA1A2 160 170 255 200 208 FR9/IP21 606x2275x605 308<br />

NXC02086A5L0SSFA1A2 160 170 255 200 208 FR9/IP54 606x2405x605 318<br />

I(H) = nominal current for 150% overload requirement (at max. 50°C ambient temperature)<br />

I(L) = nominal current for 110% overload requirement (at max. 40°C ambient temperature)<br />

I(overload) = maximum 1 min/10 min overload current (high overload)<br />

Vacon NXC Options DESCRIPTION NOTE<br />

+ACH Cabinet heater 50 W 1 x 50 W, requires +TUP *<br />

+ACL Cabinet light Requires +TUP *<br />

+AMO ICB motor operator Including Open/Close push buttons on the door, requires +TUP *<br />

+CIT Cabling Input Top Including +CIT/+COT (W:+400 mm)<br />

+DCM Analog meter + curr.trafo CT on L1<br />

+DVM Analog V-meter + sel.sw. For main voltages<br />

+GPL 100 mm base/plinth For basic drive **<br />

+ICB Circuit breaker MCCB, not with +ILS, +IFU, +IFD or +ICO<br />

+ICO Contactor AC-1 Requires +TUP *<br />

+IFD Fuse switch + aR fuses Not with +ILS, +IFU or +ICB<br />

+IFU aR fuses & base Not with +ILS, +ICB or +IFD<br />

+ILS Load switch Not with +IFU, +ICB or +IFD<br />

+MDC Terminals for DC connect. DC-connection / additional dc/brake chopper terminals<br />

+OCM Common mode chokes To be put on motor cable<br />

+ODU<br />

du/dt filter<br />

* IF UNIT ORDERED WITHOUT CONTROL VOLTAGE TRANSFORMER (ATx), THIS OPTION REQUIRES EXTERNAL 230 V SUPPLY<br />

** NOTE THAT THE OPTIONS THAT AFFECTS ON THE WIDHT OF THE CABINET REQUIRES AN EXTRA +GPL (see NXC common options on page 87)<br />

*** FOR CORRECT ORIENTATION OF DU/DT TERMINALS PLEASE ORDER ALSO +COT IF REQUIRED<br />

Vacon NXC 525-690 V, 208 A, EMC level T, air-cooled AC drive, 6-pulse supply<br />

The prices are the same as L level ones.<br />

Replace the L by T in the order typecode.<br />

SUBJECT TO CHANGE WITHOUT NOTICE<br />

Vacon Plc Runsorintie 7 65380 VAASA FINLAND tel.:+358-201-2121 fax: +358 (0)201 212 205 http://www.vacon.com 69


Vacon Plc<br />

AC drive<br />

VACON PLC<br />

Vacon NXC 525-690 V, 261 A, EMC level L, air-cooled AC drive, 6-pulse supply<br />

ORDER TYPE CODE MOTOR SHAFT POWER AND CURRENT SIZE/PROT. DIMENSIONS WEIGHT<br />

High overload Low overload FR/IP W x H x D<br />

P [kW] I(H) I(overload) P [kW] I(L) [mm] [kg]<br />

NXC02616A2L0SSFA1A2 200 208 312 250 261 FR10/IP21 606x2275x605 341<br />

NXC02616A5L0SSFA1A2 200 208 312 250 261 FR10/IP54 606x2405x605 351<br />

I(H) = nominal current for 150% overload requirement (at max. 40°C ambient temperature)<br />

I(L) = nominal current for 110% overload requirement (at max. 40°C ambient temperature)<br />

I(overload) = maximum 1 min/10 min overload current (high overload)<br />

Vacon NXC Options DESCRIPTION NOTE<br />

+ACH Cabinet heater 50 W 1 x 50 W, requires +TUP *<br />

+ACL Cabinet light Requires +TUP *<br />

+AMO ICB motor operator Including Open/Close push buttons on the door, requires +TUP *<br />

+CIT Cabling Input Top Including +CIT/+COT (W:+400 mm)<br />

+DCM Analog meter + curr.trafo CT on L1<br />

+DVM Analog V-meter + sel.sw. For main voltages<br />

+GPL 100 mm base/plinth For basic drive **<br />

+ICB Circuit breaker MCCB, not with +ILS, +IFU, +IFD or +ICO<br />

+ICO Contactor AC-1 Requires +TUP *<br />

+IFD Fuse switch + aR fuses Not with +ILS, +IFU or +ICB<br />

+IFU aR fuses & base Not with +ILS, +ICB or +IFD<br />

+ILS Load switch Not with +IFU, +ICB or +IFD<br />

+MDC Terminals for DC connect. DC-connection / additional dc/brake chopper terminals<br />

+OCM Common mode chokes To be put on motor cable<br />

+ODU du/dt filter Including +CIT/+COT (W:+400 mm) ***<br />

+OSI Sine wave filter W: +600 mm, Please check the availability from the factory<br />

* IF UNIT ORDERED WITHOUT CONTROL VOLTAGE TRANSFORMER (ATx), THIS OPTION REQUIRES EXTERNAL 230 V SUPPLY<br />

** NOTE THAT THE OPTIONS THAT AFFECTS ON THE WIDHT OF THE CABINET REQUIRES AN EXTRA +GPL (see NXC common options on page 87)<br />

*** FOR CORRECT ORIENTATION OF DU/DT TERMINALS PLEASE ORDER ALSO +COT IF REQUIRED<br />

Vacon NXC 525-690 V, 261 A, EMC level T, air-cooled AC drive, 6-pulse supply<br />

The prices are the same as L level ones.<br />

Replace the L by T in the order typecode.<br />

SUBJECT TO CHANGE WITHOUT NOTICE<br />

Vacon Plc Runsorintie 7 65380 VAASA FINLAND tel.:+358-201-2121 fax: +358 (0)201 212 205 http://www.vacon.com 70


Vacon Plc<br />

AC drive<br />

VACON PLC<br />

Vacon NXC 525-690 V, 325 A, EMC level L, air-cooled AC drive, 6-pulse supply<br />

ORDER TYPE CODE MOTOR SHAFT POWER AND CURRENT SIZE/PROT. DIMENSIONS WEIGHT<br />

High overload Low overload FR/IP W x H x D<br />

P [kW] I(H) I(overload) P [kW] I(L) [mm] [kg]<br />

NXC03256A2L0SSFA1A2 250 261 392 315 325 FR10/IP21 606x2275x605 371<br />

NXC03256A5L0SSFA1A2 250 261 392 315 325 FR10/IP54 606x2405x605 381<br />

I(H) = nominal current for 150% overload requirement (at max. 40°C ambient temperature)<br />

I(L) = nominal current for 110% overload requirement (at max. 40°C ambient temperature)<br />

I(overload) = maximum 1 min/10 min overload current (high overload)<br />

Vacon NXC Options DESCRIPTION NOTE<br />

+ACH Cabinet heater 50 W 1 x 50 W, requires +TUP *<br />

+ACL Cabinet light Requires +TUP *<br />

+AMO ICB motor operator Including Open/Close push buttons on the door, requires +TUP *<br />

+CIT Cabling Input Top Including +CIT/+COT (W:+400 mm)<br />

+DCM Analog meter + curr.trafo CT on L1<br />

+DVM Analog V-meter + sel.sw. For main voltages<br />

+GPL 100 mm base/plinth For basic drive **<br />

+ICB Circuit breaker MCCB, not with +ILS, +IFU, +IFD or +ICO<br />

+ICO Contactor AC-1 Requires +TUP *<br />

+IFD Fuse switch + aR fuses Not with +ILS, +IFU or +ICB<br />

+IFU aR fuses & base Not with +ILS, +ICB or +IFD<br />

+ILS Load switch Not with +IFU, +ICB or +IFD<br />

+MDC Terminals for DC connect. DC-connection / additional dc/brake chopper terminals<br />

+OCM Common mode chokes To be put on motor cable<br />

+ODU du/dt filter Including +CIT/+COT (W:+400 mm) ***<br />

+OSI Sine wave filter W: +600 mm, Please check the availability from the factory<br />

* IF UNIT ORDERED WITHOUT CONTROL VOLTAGE TRANSFORMER (ATx), THIS OPTION REQUIRES EXTERNAL 230 V SUPPLY<br />

** NOTE THAT THE OPTIONS THAT AFFECTS ON THE WIDHT OF THE CABINET REQUIRES AN EXTRA +GPL (see NXC common options on page 87)<br />

*** FOR CORRECT ORIENTATION OF DU/DT TERMINALS PLEASE ORDER ALSO +COT IF REQUIRED<br />

Vacon NXC 525-690 V, 325 A, EMC level T, air-cooled AC drive, 6-pulse supply<br />

The prices are the same as L level ones.<br />

Replace the L by T in the order typecode.<br />

SUBJECT TO CHANGE WITHOUT NOTICE<br />

Vacon Plc Runsorintie 7 65380 VAASA FINLAND tel.:+358-201-2121 fax: +358 (0)201 212 205 http://www.vacon.com 71


Vacon Plc<br />

AC drive<br />

VACON PLC<br />

Vacon NXC 525-690 V, 385 A, EMC level L, air-cooled AC drive, 6-pulse supply<br />

ORDER TYPE CODE MOTOR SHAFT POWER AND CURRENT SIZE/PROT. DIMENSIONS WEIGHT<br />

High overload Low overload FR/IP W x H x D<br />

P [kW] I(H) I(overload) P [kW] I(L) [mm] [kg]<br />

NXC03856A2L0SSFA1A2 315 325 488 355 385 FR10/IP21 606x2275x605 371<br />

NXC03856A5L0SSFA1A2 315 325 488 355 385 FR10/IP54 606x2405x605 381<br />

I(H) = nominal current for 150% overload requirement (at max. 40°C ambient temperature)<br />

I(L) = nominal current for 110% overload requirement (at max. 40°C ambient temperature)<br />

I(overload) = maximum 1 min/10 min overload current (high overload)<br />

Vacon NXC Options DESCRIPTION NOTE<br />

+ACH Cabinet heater 50 W 1 x 50 W, requires +TUP *<br />

+ACL Cabinet light Requires +TUP *<br />

+AMO ICB motor operator Including Open/Close push buttons on the door, requires +TUP *<br />

+CIT Cabling Input Top Including +CIT/+COT (W:+400 mm)<br />

+DCM Analog meter + curr.trafo CT on L1<br />

+DVM Analog V-meter + sel.sw. For main voltages<br />

+GPL 100 mm base/plinth For basic drive **<br />

+ICB Circuit breaker MCCB, not with +ILS, +IFU, +IFD or +ICO<br />

+IFD Fuse switch + aR fuses Not with +ILS, +IFU or +ICB<br />

+IFU aR fuses & base Not with +ILS, +ICB or +IFD<br />

+ICO Contactor AC-1 Requires +TUP *<br />

+ILS Load switch Not with +IFU, +ICB or +IFD<br />

+MDC Terminals for DC connect. DC-connection / additional dc/brake chopper terminals<br />

+OCM Common mode chokes To be put on motor cable<br />

+ODU du/dt filter Including +CIT/+COT (W:+400 mm) ***<br />

+OSI Sine wave filter W: +600 mm, Please check the availability from the factory<br />

* IF UNIT ORDERED WITHOUT CONTROL VOLTAGE TRANSFORMER (ATx), THIS OPTION REQUIRES EXTERNAL 230 V SUPPLY<br />

** NOTE THAT THE OPTIONS THAT AFFECTS ON THE WIDHT OF THE CABINET REQUIRES AN EXTRA +GPL (see NXC common options on page 87)<br />

*** FOR CORRECT ORIENTATION OF DU/DT TERMINALS PLEASE ORDER ALSO +COT IF REQUIRED<br />

Vacon NXC 525-690 V, 385 A, EMC level T, air-cooled AC drive, 6-pulse supply<br />

The prices are the same as L level ones.<br />

Replace the L by T in the order typecode.<br />

SUBJECT TO CHANGE WITHOUT NOTICE<br />

Vacon Plc Runsorintie 7 65380 VAASA FINLAND tel.:+358-201-2121 fax: +358 (0)201 212 205 http://www.vacon.com 72


Vacon Plc<br />

AC drive<br />

VACON PLC<br />

Vacon NXC 525-690 V, 416 A, EMC level L, air-cooled AC drive, 6-pulse supply<br />

ORDER TYPE CODE MOTOR SHAFT POWER AND CURRENT SIZE/PROT. DIMENSIONS WEIGHT<br />

High overload Low overload FR/IP W x H x D<br />

P [kW] I(H) I(overload) P [kW] I(L) [mm] [kg]<br />

NXC04166A2L0SSFA1A2 * 315 325 488 400 416 FR10/IP21 606x2275x605 371<br />

NXC04166A5L0SSFA1A2 * 315 325 488 400 416 FR10/IP54 606x2405x605 381<br />

* max. 35 C ambient temperature<br />

I(H) = nominal current for 150% overload requirement (at max. 40°C ambient temperature)<br />

I(L) = nominal current for 110% overload requirement (at max. 40°C ambient temperature)<br />

I(overload) = maximum 1 min/10 min overload current (high overload)<br />

Vacon NXC Options DESCRIPTION NOTE<br />

+ACH Cabinet heater 50 W 1 x 50 W, requires +TUP **<br />

+ACL Cabinet light Requires +TUP **<br />

+AMO ICB motor operator Including Open/Close push buttons on the door, requires +TUP **<br />

+CIT Cabling Input Top Including +CIT/+COT (W:+400 mm)<br />

+DCM Analog meter + curr.trafo CT on L1<br />

+DVM Analog V-meter + sel.sw. For main voltages<br />

+GPL 100 mm base/plinth For basic drive ***<br />

+ICB Circuit breaker MCCB, not with +ILS, +IFU, +IFD or +ICO<br />

+IFD Fuse switch + aR fuses Not with +ILS, +IFU or +ICB<br />

+IFU aR fuses & base Not with +ILS, +ICB or +IFD<br />

+ICO Contactor AC-1 Requires +TUP **<br />

+ILS Load switch Not with +IFU, +ICB or +IFD<br />

+MDC Terminals for DC connect. DC-connection / additional dc/brake chopper terminals<br />

+OCM Common mode chokes To be put on motor cable<br />

+ODU du/dt filter Including +CIT/+COT (W:+400 mm) ****<br />

+OSI Sine wave filter W: +600 mm, Please check the availability from the factory<br />

** IF UNIT ORDERED WITHOUT CONTROL VOLTAGE TRANSFORMER (ATx), THIS OPTION REQUIRES EXTERNAL 230 V SUPPLY<br />

*** NOTE THAT THE OPTIONS THAT AFFECTS ON THE WIDHT OF THE CABINET REQUIRES AN EXTRA +GPL (see NXC common options on page 87)<br />

**** FOR CORRECT ORIENTATION OF DU/DT TERMINALS PLEASE ORDER ALSO +COT IF REQUIRED<br />

Vacon NXC 525-690 V, 416 A, EMC level T, air-cooled AC drive, 6-pulse supply<br />

The prices are the same as L level ones.<br />

Replace the L by T in the order typecode.<br />

SUBJECT TO CHANGE WITHOUT NOTICE<br />

Vacon Plc Runsorintie 7 65380 VAASA FINLAND tel.:+358-201-2121 fax: +358 (0)201 212 205 http://www.vacon.com 73


Vacon Plc<br />

AC drive<br />

VACON PLC<br />

Vacon NXC 525-690 V, 460 A, EMC level L, air-cooled AC drive, 6-pulse supply<br />

ORDER TYPE CODE MOTOR SHAFT POWER AND CURRENT SIZE/PROT. DIMENSIONS WEIGHT<br />

High overload Low overload FR/IP W x H x D<br />

P [kW] I(H) I(overload) P [kW] I(L) [mm] [kg]<br />

NXC04606A2L0SSFA1A2 355 385 578 450 460 FR11/IP21 806x2275x605 577<br />

NXC04606A5L0SSFA1A2 355 385 578 450 460 FR11/IP54 806x2405x605 590<br />

I(H) = nominal current for 150% overload requirement (at max. 40°C ambient temperature)<br />

I(L) = nominal current for 110% overload requirement (at max. 40°C ambient temperature)<br />

I(overload) = maximum 1 min/10 min overload current (high overload)<br />

Vacon NXC Options DESCRIPTION NOTE<br />

+ACH Cabinet heater 50 W 1 x 50 W, requires +TUP *<br />

+ACL Cabinet light Requires +TUP *<br />

+AMO ICB motor operator Including Open/Close push buttons on the door, requires +TUP *<br />

+CIT Cabling Input Top Including +CIT/+COT (W:+400 mm)<br />

+DCM Analog meter + curr.trafo CT on L1<br />

+DVM Analog V-meter + sel.sw. For main voltages<br />

+GPL 100 mm base/plinth For basic drive **<br />

+ICB Circuit breaker MCCB, not with +ILS, +IFU, +IFD or +ICO<br />

+ICO Contactor AC-1 Requires +TUP *<br />

+IFD Fuse switch + aR fuses Not with +ILS, +IFU or +ICB<br />

+IFU aR fuses & base Not with +ILS, +ICB or +IFD<br />

+ILS Load switch Not with +IFU, +ICB or +IFD<br />

+MDC Terminals for DC connect. DC-connection / additional dc/brake chopper terminals<br />

+OCM Common mode chokes To be put on motor cable<br />

+ODU du/dt filter Including +CIT/+COT (W:+400 mm) ***<br />

+OSI Sine wave filter W: +600 mm, Please check the availability from the factory<br />

* IF UNIT ORDERED WITHOUT CONTROL VOLTAGE TRANSFORMER (ATx), THIS OPTION REQUIRES EXTERNAL 230 V SUPPLY<br />

** NOTE THAT THE OPTIONS THAT AFFECTS ON THE WIDHT OF THE CABINET REQUIRES AN EXTRA +GPL (see NXC common options on page 87)<br />

*** FOR CORRECT ORIENTATION OF DU/DT TERMINALS PLEASE ORDER ALSO +COT IF REQUIRED<br />

Vacon NXC 525-690 V, 460 A, EMC level T, air-cooled AC drive, 6-pulse supply<br />

The prices are the same as L level ones.<br />

Replace the L by T in the order typecode.<br />

SUBJECT TO CHANGE WITHOUT NOTICE<br />

Vacon Plc Runsorintie 7 65380 VAASA FINLAND tel.:+358-201-2121 fax: +358 (0)201 212 205 http://www.vacon.com 74


Vacon Plc<br />

AC drive<br />

VACON PLC<br />

Vacon NXC 525-690 V, 502 A, EMC level L, air-cooled AC drive, 6-pulse supply<br />

ORDER TYPE CODE MOTOR SHAFT POWER AND CURRENT SIZE/PROT. DIMENSIONS WEIGHT<br />

High overload Low overload FR/IP W x H x D<br />

P [kW] I(H) I(overload) P [kW] I(L) [mm] [kg]<br />

NXC05026A2L0SSFA1A2 450 460 690 500 502 FR11/IP21 806x2275x605 524<br />

NXC05026A5L0SSFA1A2 450 460 690 500 502 FR11/IP54 806x2405x605 537<br />

I(H) = nominal current for 150% overload requirement (at max. 40°C ambient temperature)<br />

I(L) = nominal current for 110% overload requirement (at max. 40°C ambient temperature)<br />

I(overload) = maximum 1 min/10 min overload current (high overload)<br />

Vacon NXC Options DESCRIPTION NOTE<br />

+ACH Cabinet heater 50 W 1 x 50 W, requires +TUP *<br />

+ACL Cabinet light Requires +TUP *<br />

+AMO ICB motor operator Including Open/Close push buttons on the door, requires +TUP *<br />

+CIT Cabling Input Top Including +CIT/+COT (W:+400 mm)<br />

+DCM Analog meter + curr.trafo CT on L1<br />

+DVM Analog V-meter + sel.sw. For main voltages<br />

+GPL 100 mm base/plinth For basic drive **<br />

+ICB Circuit breaker MCCB, not with +ILS, +IFU, +IFD or +ICO<br />

+ICO Contactor AC-1 Requires +TUP *<br />

+IFD Fuse switch + aR fuses Not with +ILS, +IFU or +ICB<br />

+IFU aR fuses & base Not with +ILS, +ICB or +IFD<br />

+ILS Load switch Not with +IFU, +ICB or +IFD<br />

+MDC Terminals for DC connect. DC-connection / additional dc/brake chopper terminals<br />

+OCM Common mode chokes To be put on motor cable<br />

+ODU du/dt filter Including +CIT/+COT (W:+400 mm) ***<br />

+OSI Sine wave filter W: +800 mm, Please check the availability from the factory<br />

* IF UNIT ORDERED WITHOUT CONTROL VOLTAGE TRANSFORMER (ATx), THIS OPTION REQUIRES EXTERNAL 230 V SUPPLY<br />

** NOTE THAT THE OPTIONS THAT AFFECTS ON THE WIDHT OF THE CABINET REQUIRES AN EXTRA +GPL (see NXC common options on page 87)<br />

*** FOR CORRECT ORIENTATION OF DU/DT TERMINALS PLEASE ORDER ALSO +COT IF REQUIRED<br />

Vacon NXC 525-690 V, 502 A, EMC level T, air-cooled AC drive, 6-pulse supply<br />

The prices are the same as L level ones.<br />

Replace the L by T in the order typecode.<br />

SUBJECT TO CHANGE WITHOUT NOTICE<br />

Vacon Plc Runsorintie 7 65380 VAASA FINLAND tel.:+358-201-2121 fax: +358 (0)201 212 205 http://www.vacon.com 75


Vacon Plc<br />

AC drive<br />

VACON PLC<br />

Vacon NXC 525-690 V, 590 A, EMC level L, air-cooled AC drive, 6-pulse supply<br />

ORDER TYPE CODE MOTOR SHAFT POWER AND CURRENT SIZE/PROT. DIMENSIONS WEIGHT<br />

High overload Low overload FR/IP W x H x D<br />

P [kW] I(H) I(overload) P [kW] I(L) [mm] [kg]<br />

NXC05906A2L0SSFA1A2 * 500 502 753 560 590 FR11/IP21 806x2275x605 577<br />

NXC05906A5L0SSFA1A2 * 500 502 753 560 590 FR11/IP54 806x2445x605 590<br />

* max. 35 C ambient temperature<br />

I(H) = nominal current for 150% overload requirement (at max. 40°C ambient temperature)<br />

I(L) = nominal current for 110% overload requirement (at max. 40°C ambient temperature)<br />

I(overload) = maximum 1 min/10 min overload current (high overload)<br />

Vacon NXC Options DESCRIPTION NOTE<br />

+ACH Cabinet heater 50 W 1 x 50 W, requires +TUP **<br />

+ACL Cabinet light Requires +TUP **<br />

+AMO ICB motor operator Including Open/Close push buttons on the door, requires +TUP **<br />

+CIT Cabling Input Top Including +CIT/+COT (W:+400 mm)<br />

+DCM Analog meter + curr.trafo CT on L1<br />

+DVM Analog V-meter + sel.sw. For main voltages<br />

+GPL 100 mm base/plinth For basic drive ***<br />

+ICB Circuit breaker MCCB, not with +ILS, +IFU, +IFD or +ICO, requires +TUP **<br />

+ICO Contactor AC-1 Requires +TUP **<br />

+IFD Fuse switch + aR fuses Not with +ILS, +IFU or +ICB<br />

+IFU aR fuses & base Not with +ILS, +ICB or +IFD<br />

+ILS Load switch Not with +IFU, +ICB or +IFD<br />

+MDC Terminals for DC connect. DC-connection / additional dc/brake chopper terminals<br />

+OCM Common mode chokes To be put on motor cable<br />

+ODU du/dt filter Including +CIT/+COT (W:+400 mm) ****<br />

+OSI Sine wave filter W: +800 mm, Please check the availability from the factory<br />

** IF UNIT ORDERED WITHOUT CONTROL VOLTAGE TRANSFORMER (ATx), THIS OPTION REQUIRES EXTERNAL 230 V SUPPLY<br />

*** NOTE THAT THE OPTIONS THAT AFFECTS ON THE WIDHT OF THE CABINET REQUIRES AN EXTRA +GPL (see NXC common options on page 87)<br />

**** FOR CORRECT ORIENTATION OF DU/DT TERMINALS PLEASE ORDER ALSO +COT IF REQUIRED<br />

Vacon NXC 525-690 V, 590 A, EMC level T, air-cooled AC drive, 6-pulse supply<br />

The prices are the same as L level ones.<br />

Replace the L by T in the order typecode.<br />

SUBJECT TO CHANGE WITHOUT NOTICE<br />

Vacon Plc Runsorintie 7 65380 VAASA FINLAND tel.:+358-201-2121 fax: +358 (0)201 212 205 http://www.vacon.com 76


Vacon Plc<br />

AC drive<br />

VACON PLC<br />

Vacon NXC 525-690 V, 650 A, EMC level L, air-cooled AC drive, 6-pulse supply<br />

ORDER TYPE CODE MOTOR SHAFT POWER AND CURRENT SIZE/PROT. DIMENSIONS WEIGHT<br />

High overload Low overload FR/IP W x H x D<br />

P [kW] I(H) I(overload) P [kW] I(L) [mm] [kg]<br />

NXC06506A2L0SSFA1A2 560 590 885 630 650 FR12/IP21 1206x2275x605 745<br />

NXC06506A5L0SSFA1A2 560 590 885 630 650 FR12/IP54 1206x2405x605 765<br />

I(H) = nominal current for 150% overload requirement (at max. 40°C ambient temperature)<br />

I(L) = nominal current for 110% overload requirement (at max. 40°C ambient temperature)<br />

I(overload) = maximum 1 min/10 min overload current (high overload)<br />

Vacon NXC Options DESCRIPTION NOTE<br />

+ACH Cabinet heater 50 W 1 x 50 W, requires +TUP *<br />

+ACL Cabinet light Requires +TUP *<br />

+CIT Cabling Input Top Including +CIT/+COT (W:+400 mm)<br />

+DCM Analog meter + curr.trafo CT on L1<br />

+DVM Analog V-meter + sel.sw. For main voltages<br />

+GPL 100 mm base/plinth For basic drive **<br />

+ICB Circuit breaker, including +AMO MCCB, not with +ILS, +IFU, +IFD or +ICO, requires +TUP *<br />

+ICO Contactor AC-1 Requires +TUP *<br />

+IFD Fuse switch + aR fuses Not with +ILS, +IFU or +ICB<br />

+IFU aR fuses & base Not with +ILS, +ICB or +IFD<br />

+ILS Load switch Not with +IFU, +ICB or +IFD<br />

+MDC Terminals for resistor connect. Brake chopper terminals<br />

+OCM Common mode chokes To be put on motor cable<br />

+ODU du/dt filter Including +CIT/+COT (W:+400 mm) ***<br />

+OSI Sine wave filter W: +2x600 mm, Please check the availability from the factory<br />

* IF UNIT ORDERED WITHOUT CONTROL VOLTAGE TRANSFORMER (ATx), THIS OPTION REQUIRES EXTERNAL 230 V SUPPLY<br />

** NOTE THAT THE OPTIONS THAT AFFECTS ON THE WIDHT OF THE CABINET REQUIRES AN EXTRA +GPL (see NXC common options on page 87)<br />

*** FOR CORRECT ORIENTATION OF DU/DT TERMINALS PLEASE ORDER ALSO +COT IF REQUIRED<br />

Vacon NXC 525-690 V, 650 A, EMC level T, air-cooled AC drive, 6-pulse supply<br />

The prices are the same as L level ones.<br />

Replace the L by T in the order typecode.<br />

SUBJECT TO CHANGE WITHOUT NOTICE<br />

Vacon Plc Runsorintie 7 65380 VAASA FINLAND tel.:+358-201-2121 fax: +358 (0)201 212 205 http://www.vacon.com 77


Vacon Plc<br />

AC drive<br />

VACON PLC<br />

Vacon NXC 525-690 V, 750 A, EMC level L, air-cooled AC drive, 6-pulse supply<br />

ORDER TYPE CODE MOTOR SHAFT POWER AND CURRENT SIZE/PROT. DIMENSIONS WEIGHT<br />

High overload Low overload FR/IP W x H x D<br />

P [kW] I(H) I(overload) P [kW] I(L) [mm] [kg]<br />

NXC07506A2L0SSFA1A2 630 650 975 710 750 FR12/IP21 1206x2275x605 745<br />

NXC07506A5L0SSFA1A2 630 650 975 710 750 FR12/IP54 1206x2405x605 765<br />

I(H) = nominal current for 150% overload requirement (at max. 40°C ambient temperature)<br />

I(L) = nominal current for 110% overload requirement (at max. 40°C ambient temperature)<br />

I(overload) = maximum 1 min/10 min overload current (high overload)<br />

Vacon NXC Options DESCRIPTION NOTE<br />

+ACH Cabinet heater 50 W 1 x 50 W, requires +TUP *<br />

+ACL Cabinet light Requires +TUP *<br />

+CIT Cabling Input Top Including +CIT/+COT (W:+400 mm)<br />

+DCM Analog meter + curr.trafo CT on L1<br />

+DVM Analog V-meter + sel.sw. For main voltages<br />

+GPL 100 mm base/plinth For basic drive **<br />

+ICB Circuit breaker, including +AMO MCCB, not with +ILS, +IFU, +IFD or +ICO, requires +TUP *<br />

+ICO Contactor AC-1 Requires +TUP *<br />

+IFD Fuse switch + aR fuses Not with +ILS, +IFU or +ICB<br />

+IFU aR fuses & base Not with +ILS, +ICB or +IFD<br />

+ILS Load switch Not with +IFU, +ICB or +IFD<br />

+MDC Terminals for resistor connect. Brake chopper terminals<br />

+OCM Common mode chokes To be put on motor cable<br />

+ODU du/dt filter Including +CIT/+COT (W:+400 mm) ***<br />

+OSI Sine wave filter W: +2x600 mm, Please check the availability from the factory<br />

* IF UNIT ORDERED WITHOUT CONTROL VOLTAGE TRANSFORMER (ATx), THIS OPTION REQUIRES EXTERNAL 230 V SUPPLY<br />

** NOTE THAT THE OPTIONS THAT AFFECTS ON THE WIDHT OF THE CABINET REQUIRES AN EXTRA +GPL (see NXC common options on page 87)<br />

*** FOR CORRECT ORIENTATION OF DU/DT TERMINALS PLEASE ORDER ALSO +COT IF REQUIRED<br />

Vacon NXC 525-690 V, 750 A, EMC level L, air-cooled AC drive, 6-pulse supply<br />

The prices are the same as L level ones.<br />

Replace the L by T in the order typecode.<br />

SUBJECT TO CHANGE WITHOUT NOTICE<br />

Vacon Plc Runsorintie 7 65380 VAASA FINLAND tel.:+358-201-2121 fax: +358 (0)201 212 205 http://www.vacon.com 78


Vacon Plc<br />

AC drive<br />

VACON PLC<br />

Vacon NXC 525-690 V, 820 A, EMC level L, air-cooled AC drive, 6-pulse supply<br />

ORDER TYPE CODE MOTOR SHAFT POWER AND CURRENT SIZE/PROT. DIMENSIONS WEIGHT<br />

High overload Low overload FR/IP W x H x D<br />

P [kW] I(H) I(overload) P [kW] I(L) [mm] [kg]<br />

NXC08206A2L0SSFA1A2 * 710 750 975 800 820 FR12/IP21 1206x2275x605 745<br />

NXC08206A5L0SSFA1A2 * 710 750 975 800 820 FR12/IP54 1206x2405x605 765<br />

* max. 35 C ambient temperature<br />

I(H) = nominal current for 150% overload requirement (at max. 40°C ambient temperature)<br />

I(L) = nominal current for 110% overload requirement (at max. 40°C ambient temperature)<br />

I(overload) = maximum 1 min/10 min overload current (high overload)<br />

Vacon NXC Options DESCRIPTION NOTE<br />

+ACH Cabinet heater 50 W 1 x 50 W, requires +TUP **<br />

+ACL Cabinet light Requires +TUP **<br />

+CIT Cabling Input Top Including +CIT/+COT (W:+400 mm)<br />

+DCM Analog meter + curr.trafo CT on L1<br />

+DVM Analog V-meter + sel.sw. For main voltages<br />

+GPL 100 mm base/plinth For basic drive ***<br />

+ICB Circuit breaker, including +AMO MCCB, not with +ILS, +IFU, +IFD or +ICO, requires +TUP **<br />

+ICO Contactor AC-1 Requires +TUP **<br />

+IFD Fuse switch + aR fuses Not with +ILS, +IFU or +ICB<br />

+IFU aR fuses & base Not with +ILS, +ICB or +IFD<br />

+ILS Load switch Not with +IFU, +ICB or +IFD<br />

+MDC Terminals for resistor connect. Brake chopper terminals<br />

+OCM Common mode chokes To be put on motor cable<br />

+ODU du/dt filter Including +CIT/+COT (W:+400 mm) ****<br />

+OSI Sine wave filter W: +2x600 mm, Please check the availability from the factory<br />

** IF UNIT ORDERED WITHOUT CONTROL VOLTAGE TRANSFORMER (ATx), THIS OPTION REQUIRES EXTERNAL 230 V SUPPLY<br />

*** NOTE THAT THE OPTIONS THAT AFFECTS ON THE WIDHT OF THE CABINET REQUIRES AN EXTRA +GPL (see NXC common options on page 87)<br />

**** FOR CORRECT ORIENTATION OF DU/DT TERMINALS PLEASE ORDER ALSO +COT IF REQUIRED<br />

Vacon NXC 525-690 V, 820 A, EMC level T, air-cooled AC drive, 6-pulse supply<br />

The prices are the same as L level ones.<br />

Replace the L by T in the order typecode.<br />

SUBJECT TO CHANGE WITHOUT NOTICE<br />

Vacon Plc Runsorintie 7 65380 VAASA FINLAND tel.:+358-201-2121 fax: +358 (0)201 212 205 http://www.vacon.com 79


Vacon Plc<br />

AC drive<br />

VACON PLC<br />

Vacon NXC 525-690 V, 920 A, EMC level L, air-cooled AC drive, 6-pulse supply<br />

ORDER TYPE CODE MOTOR SHAFT POWER AND CURRENT SIZE/PROT. DIMENSIONS WEIGHT<br />

High overload Low overload FR/IP W x H x D<br />

P [kW] I(H) I(overload) P [kW] I(L) [mm] [kg]<br />

NXC09206A2L0SSFA1A2 +IFD 800 820 1230 900 920 FR13/IP21 1406x2275x605 1050<br />

NXC09206A5L0SSFA1A2 +IFD 800 820 1230 900 920 FR13/IP54 1406x2405x605 1060<br />

+IFD (Load switch + bolt-on fuses) INCLUDED AS STANDARD<br />

I(H) = nominal current for 150% overload requirement (at max. 40°C ambient temperature)<br />

I(L) = nominal current for 110% overload requirement (at max. 40°C ambient temperature)<br />

I(overload) = maximum 1 min/10 min overload current (high overload)<br />

Vacon NXC Options DESCRIPTION NOTE<br />

+ACH Cabinet heater 50 W 1 x 50 W, requires +TUP *<br />

+ACL Cabinet light Requires +TUP *<br />

+CIT Cabling Input Top Including +CIT/+COT (W:+400 mm)<br />

+DCM Analog meter + curr.trafo CT on L1<br />

+DVM Analog V-meter + sel.sw. For main voltages<br />

+GPL 100 mm base/plinth For basic drive **<br />

+ICB Circuit breaker, including +AMO MCCB; not with +IFD, (upgrades +IFD to +ICB), requires +TUP *<br />

+MDC Terminals for DC connect. Including +CIT/+COT (W:+400 mm)<br />

+OCM Common mode chokes To be put on motor cable<br />

+ODU<br />

du/dt filter<br />

+OSI Sine wave filter W: +800 mm, Please check the availability from the factory<br />

* IF UNIT ORDERED WITHOUT CONTROL VOLTAGE TRANSFORMER (ATx), THIS OPTION REQUIRES EXTERNAL 230 V SUPPLY<br />

** NOTE THAT THE OPTIONS THAT AFFECTS ON THE WIDHT OF THE CABINET REQUIRES AN EXTRA +GPL (see NXC common options on page 87)<br />

Vacon NXC 525-690 V, 920 A, EMC level T, air-cooled AC drive, 6-pulse supply<br />

The prices are the same as L level ones.<br />

Replace the L by T in the order typecode.<br />

SUBJECT TO CHANGE WITHOUT NOTICE<br />

Vacon Plc Runsorintie 7 65380 VAASA FINLAND tel.:+358-201-2121 fax: +358 (0)201 212 205 http://www.vacon.com 80


Vacon Plc<br />

AC drive<br />

VACON PLC<br />

Vacon NXC 525-690 V, 1030 A, EMC level L, air-cooled AC drive, 6-pulse supply<br />

ORDER TYPE CODE MOTOR SHAFT POWER AND CURRENT SIZE/PROT. DIMENSIONS WEIGHT<br />

High overload Low overload FR/IP W x H x D<br />

P [kW] I(H) I(overload) P [kW] I(L) [mm] [kg]<br />

NXC10306A2L0SSFA1A2 +IFD 900 920 1380 1000 1030 FR13/IP21 1406x2275x605 1050<br />

NXC10306A5L0SSFA1A2 +IFD 900 920 1380 1000 1030 FR13/IP54 1406x2405x605 1060<br />

+IFD (Load switch + bolt-on fuses) INCLUDED AS STANDARD<br />

I(H) = nominal current for 150% overload requirement (at max. 40°C ambient temperature)<br />

I(L) = nominal current for 110% overload requirement (at max. 40°C ambient temperature)<br />

I(overload) = maximum 1 min/10 min overload current (high overload)<br />

Vacon NXC Options DESCRIPTION NOTE<br />

+ACH Cabinet heater 50 W 1 x 50 W, requires +TUP *<br />

+ACL Cabinet light Requires +TUP *<br />

+CIT Cabling Input Top Including +CIT/+COT (W:+400 mm)<br />

+DCM Analog meter + curr.trafo CT on L1<br />

+DVM Analog V-meter + sel.sw. For main voltages<br />

+GPL 100 mm base/plinth For basic drive **<br />

+ICB Circuit breaker, including +AMO MCCB; not with +IFD, (upgrades +IFD to +ICB), requires +TUP *<br />

+MDC Terminals for DC connect. Including +CIT/+COT (W:+400 mm)<br />

+OCM Common mode chokes To be put on motor cable<br />

+ODU<br />

du/dt filter<br />

+OSI Sine wave filter W: +800 mm, Please check the availability from the factory<br />

* IF UNIT ORDERED WITHOUT CONTROL VOLTAGE TRANSFORMER (ATx), THIS OPTION REQUIRES EXTERNAL 230 V SUPPLY<br />

** NOTE THAT THE OPTIONS THAT AFFECTS ON THE WIDHT OF THE CABINET REQUIRES AN EXTRA +GPL (see NXC common options on page 87)<br />

Vacon NXC 525-690 V, 1030 A, EMC level T, air-cooled AC drive, 6-pulse supply<br />

The prices are the same as L level ones.<br />

Replace the L by T in the order typecode.<br />

SUBJECT TO CHANGE WITHOUT NOTICE<br />

Vacon Plc Runsorintie 7 65380 VAASA FINLAND tel.:+358-201-2121 fax: +358 (0)201 212 205 http://www.vacon.com 81


Vacon Plc<br />

AC drive<br />

VACON PLC<br />

Vacon NXC 525-690 V, 1180 A, EMC level L, air-cooled AC drive, 6-pulse supply<br />

ORDER TYPE CODE MOTOR SHAFT POWER AND CURRENT SIZE/PROT. DIMENSIONS WEIGHT<br />

High overload Low overload FR/IP W x H x D<br />

P [kW] I(H) I(overload) P [kW] I(L) [mm] [kg]<br />

NXC11806A2L0SSFA1A2 +IFD* 1000 1030 1463 1150 1180 FR13/IP21 1406x2275x605 1050<br />

NXC11806A5L0SSFA1A2 +IFD* 1000 1030 1463 1150 1180 FR13/IP54 1406x2405x605 1060<br />

+IFD (Load switch + bolt-on fuses) INCLUDED AS STANDARD<br />

* max. 35 C ambient temperature<br />

I(H) = nominal current for 150% overload requirement (at max. 40°C ambient temperature)<br />

I(L) = nominal current for 110% overload requirement (at max. 40°C ambient temperature)<br />

I(overload) = maximum 1 min/10 min overload current (high overload)<br />

Vacon NXC Options DESCRIPTION NOTE<br />

+ACH Cabinet heater 50 W 1 x 50 W, requires +TUP **<br />

+ACL Cabinet light Requires +TUP **<br />

+CIT Cabling Input Top Including +CIT/+COT (W:+400 mm)<br />

+DCM Analog meter + curr.trafo CT on L1<br />

+DVM Analog V-meter + sel.sw. For main voltages<br />

+GPL 100 mm base/plinth For basic drive ***<br />

+ICB Circuit breaker, including +AMO MCCB; not with +IFD, (upgrades +IFD to +ICB), requires +TUP *<br />

+MDC Terminals for DC connect. Including +CIT/+COT (W:+400 mm)<br />

+OCM Common mode chokes To be put on motor cable<br />

+ODU<br />

du/dt filter<br />

+OSI Sine wave filter W: +800 mm, Please check the availability from the factory<br />

** IF UNIT ORDERED WITHOUT CONTROL VOLTAGE TRANSFORMER (ATx), THIS OPTION REQUIRES EXTERNAL 230 V SUPPLY<br />

*** NOTE THAT THE OPTIONS THAT AFFECTS ON THE WIDHT OF THE CABINET REQUIRES AN EXTRA +GPL (see NXC common options on page 87)<br />

Vacon NXC 525-690 V, 1180 A, EMC level T, air-cooled AC drive, 6-pulse supply<br />

The prices are the same as L level ones.<br />

Replace the L by T in the order typecode.<br />

SUBJECT TO CHANGE WITHOUT NOTICE<br />

Vacon Plc Runsorintie 7 65380 VAASA FINLAND tel.:+358-201-2121 fax: +358 (0)201 212 205 http://www.vacon.com 82


Vacon Plc<br />

AC drive<br />

VACON PLC<br />

Vacon NXC 525-690 V, 1500 A, EMC level L, air-cooled AC drive, 6-pulse supply<br />

ORDER TYPE CODE MOTOR SHAFT POWER AND CURRENT SIZE/PROT. DIMENSIONS WEIGHT<br />

High overload Low overload FR/IP W x H x D<br />

P [kW] I(H) I(overload) P [kW] I(L) [mm] [kg]<br />

NXC15006A2L0SSFA1A2+ODU+ICB+AMO+TUP 1300 1300 1950 1500 1500 FR14/IP21 2406x2275x605 1950<br />

NXC15006A5L0SSFA1A2+ODU+ICB+AMO+TUP 1300 1300 1950 1500 1500 FR14/IP54 2406x2405x605 1980<br />

+ODU (du/dt filter), +ICB (MCCB), +AMO (ICB motor operator), +TUP INCLUDED AS STANDARD *<br />

I(H) = nominal current for 150% overload requirement (at max. 40°C ambient temperature)<br />

I(L) = nominal current for 110% overload requirement (at max. 40°C ambient temperature)<br />

I(overload) = maximum 1 min/10 min overload current (high overload)<br />

Vacon NXC Options DESCRIPTION NOTE<br />

+ACH Cabinet heater 50 W 1 x 50 W, requires +TUP *<br />

+ACL Cabinet light Requires +TUP *<br />

+CIT Cabling Input Top Including +CIT/+COT (W:+400 mm)<br />

+DCM Analog meter + curr.trafo CT on L1<br />

+DVM Analog V-meter + sel.sw. For main voltages<br />

+GPL 100 mm base/plinth For basic drive **<br />

+OCM Common mode chokes To be put on motor cable<br />

+OSI Sine wave filter *** W: +2x800 mm<br />

* IF UNIT ORDERED WITHOUT CONTROL VOLTAGE TRANSFORMER (ATx), THIS OPTION REQUIRES EXTERNAL 230 V SUPPLY<br />

** NOTE THAT THE OPTIONS THAT AFFECTS ON THE WIDHT OF THE CABINET REQUIRES AN EXTRA +GPL (see NXC common options on page 87)<br />

***PLEASE CHECK THE AVAILABILITY FROM THE FACTORY<br />

Vacon NXC 525-690 V, 1500 A, EMC level T, air-cooled AC drive, 6-pulse supply<br />

The prices are the same as L level ones.<br />

Replace the L by T in the order typecode.<br />

SUBJECT TO CHANGE WITHOUT NOTICE<br />

Vacon Plc Runsorintie 7 65380 VAASA FINLAND tel.:+358-201-2121 fax: +358 (0)201 212 205 http://www.vacon.com 83


Vacon Plc<br />

AC drive<br />

VACON PLC<br />

Vacon NXC 525-690 V, 1900 A, EMC level L, air-cooled AC drive, 6-pulse supply<br />

ORDER TYPE CODE MOTOR SHAFT POWER AND CURRENT SIZE/PROT. DIMENSIONS WEIGHT<br />

High overload Low overload FR/IP W x H x D<br />

P [kW] I(H) I(overload) P [kW] I(L) [mm] [kg]<br />

NXC19006A2L0SSFA1A2+ODU+ICB+AMO+TUP 1500 1500 2250 1800 1900 FR14/IP21 2806x2275x605 2250<br />

NXC19006A5L0SSFA1A2+ODU+ICB+AMO+TUP 1500 1500 2250 1800 1900 FR14/IP54 2806x2405x605 2280<br />

+ODU (du/dt filter), +ICB (MCCB), +AMO (ICB motor operator), +TUP INCLUDED AS STANDARD *<br />

I(H) = nominal current for 150% overload requirement (at max. 40°C ambient temperature)<br />

I(L) = nominal current for 110% overload requirement (at max. 40°C ambient temperature)<br />

I(overload) = maximum 1 min/10 min overload current (high overload)<br />

Vacon NXC Options DESCRIPTION NOTE<br />

+ACH Cabinet heater 50 W 1 x 50 W, requires +TUP *<br />

+ACL Cabinet light Requires +TUP *<br />

+CIT Cabling Input Top Including +CIT/+COT (W:+400 mm)<br />

+DCM Analog meter + curr.trafo CT on L1<br />

+DVM Analog V-meter + sel.sw. For main voltages<br />

+GPL 100 mm base/plinth For basic drive **<br />

+OCM Common mode chokes To be put on motor cable<br />

+OSI Sine wave filter *** W: +2x800 mm<br />

* IF UNIT ORDERED WITHOUT CONTROL VOLTAGE TRANSFORMER (ATx), THIS OPTION REQUIRES EXTERNAL 230 V SUPPLY<br />

** NOTE THAT THE OPTIONS THAT AFFECTS ON THE WIDHT OF THE CABINET REQUIRES AN EXTRA +GPL (see NXC common options on page 87)<br />

***PLEASE CHECK THE AVAILABILITY FROM THE FACTORY<br />

Vacon NXC 525-690 V, 1900 A, EMC level T, air-cooled AC drive, 6-pulse supply<br />

The prices are the same as L level ones.<br />

Replace the L by T in the order typecode.<br />

SUBJECT TO CHANGE WITHOUT NOTICE<br />

Vacon Plc Runsorintie 7 65380 VAASA FINLAND tel.:+358-201-2121 fax: +358 (0)201 212 205 http://www.vacon.com 84


Vacon Plc<br />

AC drive<br />

VACON PLC<br />

Vacon NXC 525-690 V, 2250 A, EMC level L, air-cooled AC drive, 6-pulse supply<br />

ORDER TYPE CODE MOTOR SHAFT POWER AND CURRENT SIZE/PROT. DIMENSIONS WEIGHT<br />

High overload Low overload FR/IP W x H x D<br />

P [kW] I(H) I(overload) P [kW] I(L) [mm] [kg]<br />

NXC22506A2L0SSFA1A2+ODU+ICB+AMO+TUP* 1800 1900 2782 2000 2250 FR14/IP21 2806x2275x605 2300<br />

NXC22506A5L0SSFA1A2+ODU+ICB+AMO+TUP* 1800 1900 2782 2000 2250 FR14/IP54 2806x2405x605 2330<br />

+ODU (du/dt filter), +ICB (MCCB), +AMO (ICB motor operator), +TUP INCLUDED AS STANDARD **<br />

* max. 35 C ambient temperature<br />

I(H) = nominal current for 150% overload requirement (at max. 40°C ambient temperature)<br />

I(L) = nominal current for 110% overload requirement (at max. 40°C ambient temperature)<br />

I(overload) = maximum 1 min/10 min overload current (high overload)<br />

Vacon NXC Options DESCRIPTION NOTE<br />

+ACH Cabinet heater 50 W 1 x 50 W, requires +TUP **<br />

+ACL Cabinet light Requires +TUP **<br />

+CIT Cabling Input Top Including +CIT/+COT (W:+400 mm)<br />

+DCM Analog meter + curr.trafo CT on L1<br />

+DVM Analog V-meter + sel.sw. For main voltages<br />

+GPL 100 mm base/plinth For basic drive ***<br />

+OCM Common mode chokes To be put on motor cable<br />

+OSI Sine wave filter **** W: +2x800 mm<br />

** IF UNIT ORDERED WITHOUT CONTROL VOLTAGE TRANSFORMER (ATx), THIS OPTION REQUIRES EXTERNAL 230 V SUPPLY<br />

*** NOTE THAT THE OPTIONS THAT AFFECTS ON THE WIDHT OF THE CABINET REQUIRES AN EXTRA +GPL (see NXC common options on page 87)<br />

****PLEASE CHECK THE AVAILABILITY FROM THE FACTORY<br />

Vacon NXC 525-690 V, 2250 A, EMC level T, air-cooled AC drive, 6-pulse supply<br />

The prices are the same as L level ones.<br />

Replace the L by T in the order typecode.<br />

SUBJECT TO CHANGE WITHOUT NOTICE<br />

Vacon Plc Runsorintie 7 65380 VAASA FINLAND tel.:+358-201-2121 fax: +358 (0)201 212 205 http://www.vacon.com 85


Vacon Plc<br />

AC drive<br />

VACON PLC<br />

Vacon NXC 525-690 V, 261 A, EMC level L, air-cooled AC drive, 12-pulse supply<br />

ORDER TYPE CODE MOTOR SHAFT POWER AND CURRENT SIZE/PROT. DIMENSIONS WEIGHT<br />

High overload Low overload FR/IP W x H x D<br />

P [kW] I(H) I(overload) P [kW] I(L) [mm] [kg]<br />

NXC02616A2L0TSFA1A2 200 208 312 250 261 FR10/IP21 606x2275x605 341<br />

NXC02616A5L0TSFA1A2 200 208 312 250 261 FR10/IP54 606x2405x605 351<br />

I(H) = nominal current for 150% overload requirement (at max. 40°C ambient temperature)<br />

I(L) = nominal current for 110% overload requirement (at max. 40°C ambient temperature)<br />

I(overload) = maximum 1 min/10 min overload current (high overload)<br />

Vacon NXC Options DESCRIPTION NOTE<br />

+ACH Cabinet heater 50 W 1 x 50 W, requires +TUP *<br />

+ACL Cabinet light Requires +TUP *<br />

+AMO ICB motor operator Including Open/Close push buttons on the door, requires +TUP *<br />

+CIT Cabling Input Top Including +CIT/+COT (W:+400 mm)<br />

+DCM Analog meter + curr.trafo CT on L1<br />

+DVM Analog V-meter + sel.sw. For main voltages<br />

+GPL 100 mm base/plinth For basic drive **<br />

+ICB Circuit breaker MCCB, not with IFU *<br />

+IFU aR fuses & base Not with +ICB<br />

+OCM Common mode chokes To be put on motor cable<br />

+ODU du/dt filter Including +CIT/+COT (W:+400 mm) ***<br />

+OSI Sine wave filter W: +600 mm, Please check the availability from the factory<br />

* IF UNIT ORDERED WITHOUT CONTROL VOLTAGE TRANSFORMER (ATx), THIS OPTION REQUIRES EXTERNAL 230 V SUPPLY<br />

** NOTE THAT THE OPTIONS THAT AFFECTS ON THE WIDHT OF THE CABINET REQUIRES AN EXTRA +GPL (see NXC common options on page 87)<br />

*** FOR CORRECT ORIENTATION OF DU/DT TERMINALS PLEASE ORDER ALSO +COT IF REQUIRED<br />

Vacon NXC 525-690 V, 261 A, EMC level T, air-cooled AC drive, 12-pulse supply<br />

The prices are the same as L level ones.<br />

Replace the L by T in the order typecode.<br />

Vacon NXL 380-500 V, IP21, EMC level H, air-cooled AC drive<br />

SUBJECT TO CHANGE WITHOUT NOTICE<br />

Vacon Plc Runsorintie 7 65380 VAASA FINLAND tel.:+358-201-2121 fax: +358 (0)201 212 205 http://www.vacon.com 86


Vacon Plc<br />

AC drive<br />

VACON PLC<br />

Vacon NXC 525-690 V, 325 A, EMC level L, air-cooled AC drive, 12-pulse supply<br />

ORDER TYPE CODE MOTOR SHAFT POWER AND CURRENT SIZE/PROT. DIMENSIONS WEIGHT<br />

High overload Low overload FR/IP W x H x D<br />

P [kW] I(H) I(overload) P [kW] I(L) [mm] [kg]<br />

NXC03256A2L0TSFA1A2 250 261 392 315 325 FR10/IP21 606x2275x605 371<br />

NXC03256A5L0TSFA1A2 250 261 392 315 325 FR10/IP54 606x2405x605 381<br />

I(H) = nominal current for 150% overload requirement (at max. 40°C ambient temperature)<br />

I(L) = nominal current for 110% overload requirement (at max. 40°C ambient temperature)<br />

I(overload) = maximum 1 min/10 min overload current (high overload)<br />

Vacon NXC Options DESCRIPTION NOTE<br />

+ACH Cabinet heater 50 W 1 x 50 W, requires +TUP *<br />

+ACL Cabinet light Requires +TUP *<br />

+AMO ICB motor operator Including Open/Close push buttons on the door, requires +TUP *<br />

+CIT Cabling Input Top Including +CIT/+COT (W:+400 mm)<br />

+DCM Analog meter + curr.trafo CT on L1<br />

+DVM Analog V-meter + sel.sw. For main voltages<br />

+GPL 100 mm base/plinth For basic drive **<br />

+ICB Circuit breaker MCCB, not with IFU *<br />

+IFU aR fuses & base Not with ICB<br />

+OCM Common mode chokes To be put on motor cable<br />

+ODU du/dt filter Including +CIT/+COT (W:+400 mm) ***<br />

+OSI Sine wave filter W: +600 mm, Please check the availability from the factory<br />

* IF UNIT ORDERED WITHOUT CONTROL VOLTAGE TRANSFORMER (ATx), THIS OPTION REQUIRES EXTERNAL 230 V SUPPLY<br />

** NOTE THAT THE OPTIONS THAT AFFECTS ON THE WIDHT OF THE CABINET REQUIRES AN EXTRA +GPL (see NXC common options on page 87)<br />

*** FOR CORRECT ORIENTATION OF DU/DT TERMINALS PLEASE ORDER ALSO +COT IF REQUIRED<br />

Vacon NXC 525-690 V, 325 A, EMC level T, air-cooled AC drive, 12-pulse supply<br />

The prices are the same as L level ones.<br />

Replace the L by T in the order typecode.<br />

SUBJECT TO CHANGE WITHOUT NOTICE<br />

Vacon Plc Runsorintie 7 65380 VAASA FINLAND tel.:+358-201-2121 fax: +358 (0)201 212 205 http://www.vacon.com 87


Vacon Plc<br />

AC drive<br />

VACON PLC<br />

Vacon NXC 525-690 V, 385 A, EMC level L, air-cooled AC drive, 12-pulse supply<br />

ORDER TYPE CODE MOTOR SHAFT POWER AND CURRENT SIZE/PROT. DIMENSIONS WEIGHT<br />

High overload Low overload FR/IP W x H x D<br />

P [kW] I(H) I(overload) P [kW] I(L) [mm] [kg]<br />

NXC03856A2L0TSFA1A2 315 325 488 355 385 FR10/IP21 606x2275x605 371<br />

NXC03856A5L0TSFA1A2 315 325 488 355 385 FR10/IP54 606x2405x605 381<br />

I(H) = nominal current for 150% overload requirement (at max. 40°C ambient temperature)<br />

I(L) = nominal current for 110% overload requirement (at max. 40°C ambient temperature)<br />

I(overload) = maximum 1 min/10 min overload current (high overload)<br />

Vacon NXC Options DESCRIPTION NOTE<br />

+ACH Cabinet heater 50 W 1 x 50 W, requires +TUP *<br />

+ACL Cabinet light Requires +TUP *<br />

+AMO ICB motor operator Including Open/Close push buttons on the door, requires +TUP *<br />

+CIT Cabling Input Top Including +CIT/+COT (W:+400 mm)<br />

+DCM Analog meter + curr.trafo CT on L1<br />

+DVM Analog V-meter + sel.sw. For main voltages<br />

+GPL 100 mm base/plinth For basic drive **<br />

+ICB Circuit breaker MCCB, not with IFU *<br />

+IFU aR fuses & base Not with ICB<br />

+OCM Common mode chokes To be put on motor cable<br />

+ODU du/dt filter Including +CIT/+COT (W:+400 mm) ***<br />

+OSI Sine wave filter W: +600 mm, Please check the availability from the factory<br />

* IF UNIT ORDERED WITHOUT CONTROL VOLTAGE TRANSFORMER (ATx), THIS OPTION REQUIRES EXTERNAL 230 V SUPPLY<br />

** NOTE THAT THE OPTIONS THAT AFFECTS ON THE WIDHT OF THE CABINET REQUIRES AN EXTRA +GPL (see NXC common options on page 87)<br />

*** FOR CORRECT ORIENTATION OF DU/DT TERMINALS PLEASE ORDER ALSO +COT IF REQUIRED<br />

Vacon NXC 525-690 V, 385 A, EMC level T, air-cooled AC drive, 12-pulse supply<br />

The prices are the same as L level ones.<br />

Replace the L by T in the order typecode.<br />

SUBJECT TO CHANGE WITHOUT NOTICE<br />

Vacon Plc Runsorintie 7 65380 VAASA FINLAND tel.:+358-201-2121 fax: +358 (0)201 212 205 http://www.vacon.com 88


Vacon Plc<br />

AC drive<br />

VACON PLC<br />

Vacon NXC 525-690 V, 416 A, EMC level L, air-cooled AC drive, 12-pulse supply<br />

ORDER TYPE CODE MOTOR SHAFT POWER AND CURRENT SIZE/PROT. DIMENSIONS WEIGHT<br />

High overload Low overload FR/IP W x H x D<br />

P [kW] I(H) I(overload) P [kW] I(L) [mm] [kg]<br />

NXC04166A2L0TSFA1A2 * 315 325 488 400 416 FR10/IP21 606x2275x605 371<br />

NXC04166A5L0TSFA1A2 * 315 325 488 400 416 FR10/IP54 606x2405x605 381<br />

* max. 35 C ambient temperature<br />

I(H) = nominal current for 150% overload requirement (at max. 40°C ambient temperature)<br />

I(L) = nominal current for 110% overload requirement (at max. 40°C ambient temperature)<br />

I(overload) = maximum 1 min/10 min overload current (high overload)<br />

Vacon NXC Options DESCRIPTION NOTE<br />

+ACH Cabinet heater 50 W 1 x 50 W, requires +TUP **<br />

+ACL Cabinet light Requires +TUP **<br />

+AMO ICB motor operator Including Open/Close push buttons on the door, requires +TUP **<br />

+CIT Cabling Input Top Including +CIT/+COT (W:+400 mm)<br />

+DCM Analog meter + curr.trafo CT on L1<br />

+DVM Analog V-meter + sel.sw. For main voltages<br />

+GPL 100 mm base/plinth For basic drive ***<br />

+ICB Circuit breaker MCCB, not with IFU *<br />

+IFU aR fuses & base Not with ICB<br />

+OCM Common mode chokes To be put on motor cable<br />

+ODU du/dt filter Including +CIT/+COT (W:+400 mm) ****<br />

+OSI Sine wave filter W: +600 mm, Please check the availability from the factory<br />

** IF UNIT ORDERED WITHOUT CONTROL VOLTAGE TRANSFORMER (ATx), THIS OPTION REQUIRES EXTERNAL 230 V SUPPLY<br />

*** NOTE THAT THE OPTIONS THAT AFFECTS ON THE WIDHT OF THE CABINET REQUIRES AN EXTRA +GPL (see NXC common options on page 87)<br />

**** FOR CORRECT ORIENTATION OF DU/DT TERMINALS PLEASE ORDER ALSO +COT IF REQUIRED<br />

Vacon NXC 525-690 V, 416 A, EMC level T, air-cooled AC drive, 12-pulse supply<br />

The prices are the same as L level ones.<br />

Replace the L by T in the order typecode.<br />

SUBJECT TO CHANGE WITHOUT NOTICE<br />

Vacon Plc Runsorintie 7 65380 VAASA FINLAND tel.:+358-201-2121 fax: +358 (0)201 212 205 http://www.vacon.com 89


Vacon Plc<br />

AC drive<br />

VACON PLC<br />

Vacon NXC 525-690 V, 460 A, EMC level L, air-cooled AC drive, 12-pulse supply<br />

ORDER TYPE CODE MOTOR SHAFT POWER AND CURRENT SIZE/PROT. DIMENSIONS WEIGHT<br />

High overload Low overload FR/IP W x H x D<br />

P [kW] I(H) I(overload) P [kW] I(L) [mm] [kg]<br />

NXC04606A2L0TSFA1A2 355 385 578 450 460 FR11/IP21 806x2275x605 524<br />

NXC04606A5L0TSFA1A2 355 385 578 450 460 FR11/IP54 806x2405x605 537<br />

I(H) = nominal current for 150% overload requirement (at max. 40°C ambient temperature)<br />

I(L) = nominal current for 110% overload requirement (at max. 40°C ambient temperature)<br />

I(overload) = maximum 1 min/10 min overload current (high overload)<br />

Vacon NXC Options DESCRIPTION NOTE<br />

+ACH Cabinet heater 50 W 1 x 50 W, requires +TUP *<br />

+ACL Cabinet light Requires +TUP *<br />

+AMO ICB motor operator Including Open/Close push buttons on the door, requires +TUP *<br />

+CIT Cabling Input Top Including +CIT/+COT (W:+400 mm)<br />

+DCM Analog meter + curr.trafo CT on L1<br />

+DVM Analog V-meter + sel.sw. For main voltages<br />

+GPL 100 mm base/plinth For basic drive **<br />

+ICB Circuit breaker MCCB, not with ILS, IFU or IFD *<br />

+ICO Contactor AC-1 Requires +TUP *<br />

+IFD Fuse switch + aR fuses Not with +ILS, +IFU or +ICB<br />

+IFU aR fuses & base Not with ILS, IFD or ICB<br />

+ILS Load switch 630A Not with ICB, IFU or IFD<br />

+OCM Common mode chokes To be put on motor cable<br />

+ODU du/dt filter Including +CIT/+COT (W:+400 mm) ***<br />

+OSI Sine wave filter W: +600 mm, Please check the availability from the factory<br />

* IF UNIT ORDERED WITHOUT CONTROL VOLTAGE TRANSFORMER (ATx), THIS OPTION REQUIRES EXTERNAL 230 V SUPPLY<br />

** NOTE THAT THE OPTIONS THAT AFFECTS ON THE WIDHT OF THE CABINET REQUIRES AN EXTRA +GPL (see NXC common options on page 87)<br />

*** FOR CORRECT ORIENTATION OF DU/DT TERMINALS PLEASE ORDER ALSO +COT IF REQUIRED<br />

Vacon NXC 525-690 V, 460 A, EMC level T, air-cooled AC drive, 12-pulse supply<br />

The prices are the same as L level ones.<br />

Replace the L by T in the order typecode.<br />

SUBJECT TO CHANGE WITHOUT NOTICE<br />

Vacon Plc Runsorintie 7 65380 VAASA FINLAND tel.:+358-201-2121 fax: +358 (0)201 212 205 http://www.vacon.com 90


Vacon Plc<br />

AC drive<br />

VACON PLC<br />

Vacon NXC 525-690 V, 502 A, EMC level L, air-cooled AC drive, 12-pulse supply<br />

ORDER TYPE CODE MOTOR SHAFT POWER AND CURRENT SIZE/PROT. DIMENSIONS WEIGHT<br />

High overload Low overload FR/IP W x H x D<br />

P [kW] I(H) I(overload) P [kW] I(L) [mm] [kg]<br />

NXC05026A2L0TSFA1A2 450 460 690 500 502 FR11/IP21 806x2275x605 524<br />

NXC05026A5L0TSFA1A2 450 460 690 500 502 FR11/IP54 806x2405x605 537<br />

I(H) = nominal current for 150% overload requirement (at max. 40°C ambient temperature)<br />

I(L) = nominal current for 110% overload requirement (at max. 40°C ambient temperature)<br />

I(overload) = maximum 1 min/10 min overload current (high overload)<br />

Vacon NXC Options DESCRIPTION NOTE<br />

+ACH Cabinet heater 50 W 1 x 50 W, requires +TUP *<br />

+ACL Cabinet light Requires +TUP *<br />

+AMO ICB motor operator Including Open/Close push buttons on the door, requires +TUP *<br />

+CIT Cabling Input Top Including +CIT/+COT (W:+400 mm)<br />

+DCM Analog meter + curr.trafo CT on L1<br />

+DVM Analog V-meter + sel.sw. For main voltages<br />

+GPL 100 mm base/plinth For basic drive **<br />

+ICB Circuit breaker MCCB, not with ILS, IFU or IFD *<br />

+ICO Contactor AC-1 Requires +TUP *<br />

+IFD Fuse switch + aR fuses Not with +ILS, +IFU or +ICB<br />

+IFU aR fuses & base Not with ILS, IFD or ICB<br />

+ILS Load switch 630A Not with ICB, IFU or IFD<br />

+OCM Common mode chokes To be put on motor cable<br />

+ODU du/dt filter Including +CIT/+COT (W:+400 mm) ***<br />

+OSI Sine wave filter W: +800 mm, Please check the availability from the factory<br />

* IF UNIT ORDERED WITHOUT CONTROL VOLTAGE TRANSFORMER (ATx), THIS OPTION REQUIRES EXTERNAL 230 V SUPPLY<br />

** NOTE THAT THE OPTIONS THAT AFFECTS ON THE WIDHT OF THE CABINET REQUIRES AN EXTRA +GPL (see NXC common options on page 87)<br />

*** FOR CORRECT ORIENTATION OF DU/DT TERMINALS PLEASE ORDER ALSO +COT IF REQUIRED<br />

Vacon NXC 525-690 V, 502 A, EMC level T, air-cooled AC drive, 12-pulse supply<br />

The prices are the same as L level ones.<br />

Replace the L by T in the order typecode.<br />

SUBJECT TO CHANGE WITHOUT NOTICE<br />

Vacon Plc Runsorintie 7 65380 VAASA FINLAND tel.:+358-201-2121 fax: +358 (0)201 212 205 http://www.vacon.com 91


Vacon Plc<br />

AC drive<br />

VACON PLC<br />

Vacon NXC 525-690 V, 590 A, EMC level L, air-cooled AC drive, 12-pulse supply<br />

ORDER TYPE CODE MOTOR SHAFT POWER AND CURRENT SIZE/PROT. DIMENSIONS WEIGHT<br />

High overload Low overload FR/IP W x H x D<br />

P [kW] I(H) I(overload) P [kW] I(L) [mm] [kg]<br />

NXC05906A2L0TSFA1A2 * 500 502 753 560 590 FR11/IP21 806x2275x605 577<br />

NXC05906A5L0TSFA1A2 * 500 502 753 560 590 FR11/IP54 806x2445x605 590<br />

* max. 35 C ambient temperature<br />

I(H) = nominal current for 150% overload requirement (at max. 40°C ambient temperature)<br />

I(L) = nominal current for 110% overload requirement (at max. 40°C ambient temperature)<br />

I(overload) = maximum 1 min/10 min overload current (high overload)<br />

Vacon NXC Options DESCRIPTION NOTE<br />

+ACH Cabinet heater 50 W 1 x 50 W, requires +TUP **<br />

+ACL Cabinet light Requires +TUP **<br />

+AMO ICB motor operator Including Open/Close push buttons on the door, requires +TUP **<br />

+CIT Cabling Input Top Including +CIT/+COT (W:+400 mm)<br />

+DCM Analog meter + curr.trafo CT on L1<br />

+DVM Analog V-meter + sel.sw. For main voltages<br />

+GPL 100 mm base/plinth For basic drive ***<br />

+ICB Circuit breaker MCCB, not with ILS, IFU or IFD, requires +TUP **<br />

+ICO Contactor AC-1 Requires +TUP **<br />

+IFD Fuse switch + aR fuses Not with +ILS, +IFU or +ICB<br />

+IFU aR fuses & base Not with ILS, IFD or ICB<br />

+ILS Load switch 630A Not with ICB, IFU or IFD<br />

+OCM Common mode chokes To be put on motor cable<br />

+ODU du/dt filter Including +CIT/+COT (W:+400 mm) ****<br />

+OSI Sine wave filter W: +800 mm, Please check the availability from the factory<br />

** IF UNIT ORDERED WITHOUT CONTROL VOLTAGE TRANSFORMER (ATx), THIS OPTION REQUIRES EXTERNAL 230 V SUPPLY<br />

*** NOTE THAT THE OPTIONS THAT AFFECTS ON THE WIDHT OF THE CABINET REQUIRES AN EXTRA +GPL (see NXC common options on page 87)<br />

**** FOR CORRECT ORIENTATION OF DU/DT TERMINALS PLEASE ORDER ALSO +COT IF REQUIRED<br />

Vacon NXC 525-690 V, 590 A, EMC level T, air-cooled AC drive, 12-pulse supply<br />

The prices are the same as L level ones.<br />

Replace the L by T in the order typecode.<br />

SUBJECT TO CHANGE WITHOUT NOTICE<br />

Vacon Plc Runsorintie 7 65380 VAASA FINLAND tel.:+358-201-2121 fax: +358 (0)201 212 205 http://www.vacon.com 92


Vacon Plc<br />

AC drive<br />

VACON PLC<br />

Vacon NXC 525-690 V, 650 A, EMC level L, air-cooled AC drive, 12-pulse supply<br />

ORDER TYPE CODE MOTOR SHAFT POWER AND CURRENT SIZE/PROT. DIMENSIONS WEIGHT<br />

High overload Low overload FR/IP W x H x D<br />

P [kW] I(H) I(overload) P [kW] I(L) [mm] [kg]<br />

NXC06506A2L0TSFA1A2 560 590 885 630 650 FR12/IP21 1206x2275x605 745<br />

NXC06506A5L0TSFA1A2 560 590 885 630 650 FR12/IP54 1206x2405x605 765<br />

I(H) = nominal current for 150% overload requirement (at max. 40°C ambient temperature)<br />

I(L) = nominal current for 110% overload requirement (at max. 40°C ambient temperature)<br />

I(overload) = maximum 1 min/10 min overload current (high overload)<br />

Vacon NXC Options DESCRIPTION NOTE<br />

+ACH Cabinet heater 50 W 1 x 50 W, requires +TUP *<br />

+ACL Cabinet light Requires +TUP *<br />

+CIT Cabling Input Top Including +CIT/+COT (W:+400 mm)<br />

+DCM Analog meter + curr.trafo CT on L1<br />

+DVM Analog V-meter + sel.sw. For main voltages<br />

+GPL 100 mm base/plinth For basic drive **<br />

+ICB Circuit breaker, including +AMO MCCB, not with ILS, IFU or IFD, requires +TUP *<br />

+ICO Contactor AC-1 Requires +TUP *<br />

+IFD Fuse switch + aR fuses Not with +ILS, +IFU or +ICB<br />

+IFU aR fuses & base Not with ILS, IFD or ICB<br />

+ILS Load switch 630A Not with ICB, IFU or IFD<br />

+OCM Common mode chokes To be put on motor cable<br />

+ODU du/dt filter Including +CIT/+COT (W:+400 mm) ***<br />

+OSI Sine wave filter W: +2x600 mm, Please check the availability from the factory<br />

* IF UNIT ORDERED WITHOUT CONTROL VOLTAGE TRANSFORMER (ATx), THIS OPTION REQUIRES EXTERNAL 230 V SUPPLY<br />

** NOTE THAT THE OPTIONS THAT AFFECTS ON THE WIDHT OF THE CABINET REQUIRES AN EXTRA +GPL (see NXC common options on page 87)<br />

*** FOR CORRECT ORIENTATION OF DU/DT TERMINALS PLEASE ORDER ALSO +COT IF REQUIRED<br />

Vacon NXC 525-690 V, 650 A, EMC level T, air-cooled AC drive, 12-pulse supply<br />

The prices are the same as L level ones.<br />

Replace the L by T in the order typecode.<br />

SUBJECT TO CHANGE WITHOUT NOTICE<br />

Vacon Plc Runsorintie 7 65380 VAASA FINLAND tel.:+358-201-2121 fax: +358 (0)201 212 205 http://www.vacon.com 93


Vacon Plc<br />

AC drive<br />

VACON PLC<br />

Vacon NXC 525-690 V, 750 A, EMC level L, air-cooled AC drive, 12-pulse supply<br />

ORDER TYPE CODE MOTOR SHAFT POWER AND CURRENT SIZE/PROT. DIMENSIONS WEIGHT<br />

High overload Low overload FR/IP W x H x D<br />

P [kW] I(H) I(overload) P [kW] I(L) [mm] [kg]<br />

NXC07506A2L0TSFA1A2 630 650 975 710 750 FR12/IP21 1206x2275x605 745<br />

NXC07506A5L0TSFA1A2 630 650 975 710 750 FR12/IP54 1206x2405x605 765<br />

I(H) = nominal current for 150% overload requirement (at max. 40°C ambient temperature)<br />

I(L) = nominal current for 110% overload requirement (at max. 40°C ambient temperature)<br />

I(overload) = maximum 1 min/10 min overload current (high overload)<br />

Vacon NXC Options DESCRIPTION NOTE<br />

+ACH Cabinet heater 50 W 1 x 50 W, requires +TUP *<br />

+ACL Cabinet light Requires +TUP *<br />

+CIT Cabling Input Top Including +CIT/+COT (W:+400 mm)<br />

+DCM Analog meter + curr.trafo CT on L1<br />

+DVM Analog V-meter + sel.sw. For main voltages<br />

+GPL 100 mm base/plinth For basic drive **<br />

+ICB Circuit breaker, including +AMO MCCB, not with ILS, IFU or IFD, requires +TUP *<br />

+ICO Contactor AC-1 Requires +TUP *<br />

+IFD Fuse switch + aR fuses Not with +ILS, +IFU or +ICB<br />

+IFU aR fuses & base Not with ILS, IFD or ICB<br />

+ILS Load switch 630A Not with ICB, IFU or IFD<br />

+OCM Common mode chokes To be put on motor cable<br />

+ODU du/dt filter Including +CIT/+COT (W:+400 mm) **<br />

+OSI Sine wave filter W: +2x600 mm, Please check the availability from the factory<br />

* IF UNIT ORDERED WITHOUT CONTROL VOLTAGE TRANSFORMER (ATx), THIS OPTION REQUIRES EXTERNAL 230 V SUPPLY<br />

** NOTE THAT THE OPTIONS THAT AFFECTS ON THE WIDHT OF THE CABINET REQUIRES AN EXTRA +GPL (see NXC common options on page 87)<br />

*** FOR CORRECT ORIENTATION OF DU/DT TERMINALS PLEASE ORDER ALSO +COT IF REQUIRED<br />

Vacon NXC 525-690 V, 750 A, EMC level T, air-cooled AC drive, 12-pulse supply<br />

The prices are the same as L level ones.<br />

Replace the L by T in the order typecode.<br />

SUBJECT TO CHANGE WITHOUT NOTICE<br />

Vacon Plc Runsorintie 7 65380 VAASA FINLAND tel.:+358-201-2121 fax: +358 (0)201 212 205 http://www.vacon.com 94


Vacon Plc<br />

AC drive<br />

VACON PLC<br />

Vacon NXC 525-690 V, 820 A, EMC level L, air-cooled AC drive, 12-pulse supply<br />

ORDER TYPE CODE MOTOR SHAFT POWER AND CURRENT SIZE/PROT. DIMENSIONS WEIGHT<br />

High overload Low overload FR/IP W x H x D<br />

P [kW] I(H) I(overload) P [kW] I(L) [mm] [kg]<br />

NXC08206A2L0TSFA1A2 * 650 750 975 800 820 FR12/IP21 1206x2275x605 745<br />

NXC08206A5L0TSFA1A2 * 650 750 975 800 820 FR12/IP54 1206x2405x605 765<br />

* max. 35 C ambient temperature<br />

I(H) = nominal current for 150% overload requirement (at max. 40°C ambient temperature)<br />

I(L) = nominal current for 110% overload requirement (at max. 40°C ambient temperature)<br />

I(overload) = maximum 1 min/10 min overload current (high overload)<br />

Vacon NXC Options DESCRIPTION NOTE<br />

+ACH Cabinet heater 50 W 1 x 50 W, requires +TUP **<br />

+ACL Cabinet light Requires +TUP **<br />

+CIT Cabling Input Top Including +CIT/+COT (W:+400 mm)<br />

+DCM Analog meter + curr.trafo CT on L1<br />

+DVM Analog V-meter + sel.sw. For main voltages<br />

+GPL 100 mm base/plinth For basic drive ***<br />

+ICB Circuit breaker, including +AMO MCCB, not with ILS, IFU or IFD, requires +TUP **<br />

+ICO Contactor AC-1 Requires +TUP **<br />

+IFD Fuse switch + aR fuses Not with +ILS, +IFU or +ICB<br />

+IFU aR fuses & base Not with ILS, IFD or ICB<br />

+ILS Load switch 630A Not with ICB, IFU or IFD<br />

+OCM Common mode chokes To be put on motor cable<br />

+ODU du/dt filter Including +CIT/+COT (W:+400 mm) ****<br />

+OSI Sine wave filter W: +2x600 mm, Please check the availability from the factory<br />

** IF UNIT ORDERED WITHOUT CONTROL VOLTAGE TRANSFORMER (ATx), THIS OPTION REQUIRES EXTERNAL 230 V SUPPLY<br />

*** NOTE THAT THE OPTIONS THAT AFFECTS ON THE WIDHT OF THE CABINET REQUIRES AN EXTRA +GPL (see NXC common options on page 87)<br />

**** FOR CORRECT ORIENTATION OF DU/DT TERMINALS PLEASE ORDER ALSO +COT IF REQUIRED<br />

Vacon NXC 525-690 V, 820 A, EMC level T, air-cooled AC drive, 12-pulse supply<br />

The prices are the same as L level ones.<br />

Replace the L by T in the order typecode.<br />

SUBJECT TO CHANGE WITHOUT NOTICE<br />

Vacon Plc Runsorintie 7 65380 VAASA FINLAND tel.:+358-201-2121 fax: +358 (0)201 212 205 http://www.vacon.com 95


Vacon Plc<br />

AC drive<br />

VACON PLC<br />

Vacon NXC 525-690 V, 920 A, EMC level L, air-cooled AC drive, 12-pulse supply<br />

ORDER TYPE CODE MOTOR SHAFT POWER AND CURRENT SIZE/PROT. DIMENSIONS WEIGHT<br />

High overload Low overload FR/IP W x H x D<br />

P [kW] I(H) I(overload) P [kW] I(L) [mm] [kg]<br />

NXC09206A2L0TSFA1A2 +ICB +AMO +TUP 800 820 1230 900 920 FR13/IP21 1406x2275x605 1050<br />

NXC09206A5L0TSFA1A2 +ICB +AMO +TUP 800 820 1230 900 920 FR13/IP54 1406x2405x605 1060<br />

+ICB (MCCB) +AMO (ICB motor operator), +TUP INCLUDED AS STANDARD*<br />

I(H) = nominal current for 150% overload requirement (at max. 40°C ambient temperature)<br />

I(L) = nominal current for 110% overload requirement (at max. 40°C ambient temperature)<br />

I(overload) = maximum 1 min/10 min overload current (high overload)<br />

Vacon NXC Options DESCRIPTION NOTE<br />

+ACH Cabinet heater 50 W 1 x 50 W, requires +TUP *<br />

+ACL Cabinet light Requires +TUP *<br />

+CIT Cabling Input Top Including +CIT/+COT (W:+400 mm)<br />

+DCM Analog meter + curr.trafo CT on L1<br />

+DVM Analog V-meter + sel.sw. For main voltages<br />

+GPL 100 mm base/plinth For basic drive **<br />

+OCM Common mode chokes To be put on motor cable<br />

+ODU<br />

du/dt filter<br />

+OSI Sine wave filter W: +800 mm, Please check the availability from the factory<br />

* IF UNIT ORDERED WITHOUT CONTROL VOLTAGE TRANSFORMER (ATx), THIS OPTION REQUIRES EXTERNAL 230 V SUPPLY<br />

** NOTE THAT THE OPTIONS THAT AFFECTS ON THE WIDHT OF THE CABINET REQUIRES AN EXTRA +GPL (see NXC common options on page 87)<br />

Vacon NXC 525-690 V, 920 A, EMC level T, air-cooled AC drive, 12-pulse supply<br />

The prices are the same as L level ones.<br />

Replace the L by T in the order typecode.<br />

SUBJECT TO CHANGE WITHOUT NOTICE<br />

Vacon Plc Runsorintie 7 65380 VAASA FINLAND tel.:+358-201-2121 fax: +358 (0)201 212 205 http://www.vacon.com 96


Vacon Plc<br />

AC drive<br />

VACON PLC<br />

Vacon NXC 525-690 V, 1030 A, EMC level L, air-cooled AC drive, 12-pulse supply<br />

ORDER TYPE CODE MOTOR SHAFT POWER AND CURRENT SIZE/PROT. DIMENSIONS WEIGHT<br />

High overload Low overload FR/IP W x H x D<br />

P [kW] I(H) I(overload) P [kW] I(L) [mm] [kg]<br />

NXC10306A2L0TSFA1A2 +ICB +AMO +TUP 900 920 1380 1000 1030 FR13/IP21 1406x2275x605 1050<br />

NXC10306A5L0TSFA1A2 +ICB +AMO +TUP 900 920 1380 1000 1030 FR13/IP54 1406x2405x605 1060<br />

+ICB (MCCB) +AMO (ICB motor operator), +TUP INCLUDED AS STANDARD*<br />

I(H) = nominal current for 150% overload requirement (at max. 40°C ambient temperature)<br />

I(L) = nominal current for 110% overload requirement (at max. 40°C ambient temperature)<br />

I(overload) = maximum 1 min/10 min overload current (high overload)<br />

Vacon NXC Options DESCRIPTION NOTE<br />

+ACH Cabinet heater 50 W 1 x 50 W, requires +TUP *<br />

+ACL Cabinet light Requires +TUP *<br />

+CIT Cabling Input Top Including +CIT/+COT (W:+400 mm)<br />

+DCM Analog meter + curr.trafo CT on L1<br />

+DVM Analog V-meter + sel.sw. For main voltages<br />

+GPL 100 mm base/plinth For basic drive **<br />

+OCM Common mode chokes To be put on motor cable<br />

+ODU<br />

du/dt filter<br />

+OSI Sine wave filter W: +800 mm, Please check the availability from the factory<br />

* IF UNIT ORDERED WITHOUT CONTROL VOLTAGE TRANSFORMER (ATx), THIS OPTION REQUIRES EXTERNAL 230 V SUPPLY<br />

** NOTE THAT THE OPTIONS THAT AFFECTS ON THE WIDHT OF THE CABINET REQUIRES AN EXTRA +GPL (see NXC common options on page 87)<br />

Vacon NXC 525-690 V, 1030 A, EMC level T, air-cooled AC drive, 12-pulse supply<br />

The prices are the same as L level ones.<br />

Replace the L by T in the order typecode.<br />

SUBJECT TO CHANGE WITHOUT NOTICE<br />

Vacon Plc Runsorintie 7 65380 VAASA FINLAND tel.:+358-201-2121 fax: +358 (0)201 212 205 http://www.vacon.com 97


Vacon Plc<br />

AC drive<br />

VACON PLC<br />

Vacon NXC 525-690 V, 1180 A, EMC level L, air-cooled AC drive, 12-pulse supply<br />

ORDER TYPE CODE MOTOR SHAFT POWER AND CURRENT SIZE/PROT. DIMENSIONS WEIGHT<br />

High overload Low overload FR/IP W x H x D<br />

P [kW] I(H) I(overload) P [kW] I(L) [mm] [kg]<br />

NXC11806A2L0TSFA1A2 +ICB +AMO +TUP* 1000 1030 1463 1150 1180 FR13/IP21 1406x2275x605 1050<br />

NXC11806A5L0TSFA1A2 +ICB +AMO +TUP* 1000 1030 1463 1150 1180 FR13/IP54 1406x2405x605 1060<br />

+ICB (MCCB) +AMO (ICB motor operator), +TUP INCLUDED AS STANDARD*<br />

* max. 35 C ambient temperature<br />

I(H) = nominal current for 150% overload requirement (at max. 40°C ambient temperature)<br />

I(L) = nominal current for 110% overload requirement (at max. 40°C ambient temperature)<br />

I(overload) = maximum 1 min/10 min overload current (high overload)<br />

Vacon NXC Options DESCRIPTION NOTE<br />

+ACH Cabinet heater 50 W 1 x 50 W, requires +TUP **<br />

+ACL Cabinet light Requires +TUP **<br />

+CIT Cabling Input Top Including +CIT/+COT (W:+400 mm)<br />

+DCM Analog meter + curr.trafo CT on L1<br />

+DVM Analog V-meter + sel.sw. For main voltages<br />

+GPL 100 mm base/plinth For basic drive ***<br />

+OCM Common mode chokes To be put on motor cable<br />

+ODU<br />

du/dt filter<br />

+OSI Sine wave filter W: +800 mm, Please check the availability from the factory<br />

** IF UNIT ORDERED WITHOUT CONTROL VOLTAGE TRANSFORMER (ATx), THIS OPTION REQUIRES EXTERNAL 230 V SUPPLY<br />

*** NOTE THAT THE OPTIONS THAT AFFECTS ON THE WIDHT OF THE CABINET REQUIRES AN EXTRA +GPL (see NXC common options on page 87)<br />

Vacon NXC 525-690 V, 1180 A, EMC level T, air-cooled AC drive, 12-pulse supply<br />

The prices are the same as L level ones.<br />

Replace the L by T in the order typecode.<br />

SUBJECT TO CHANGE WITHOUT NOTICE<br />

Vacon Plc Runsorintie 7 65380 VAASA FINLAND tel.:+358-201-2121 fax: +358 (0)201 212 205 http://www.vacon.com 98


Vacon Plc<br />

AC drive<br />

VACON PLC<br />

Vacon NXC 525-690 V, 1500 A, EMC level L, air-cooled AC drive, 12-pulse supply<br />

ORDER TYPE CODE MOTOR SHAFT POWER AND CURRENT SIZE/PROT. DIMENSIONS WEIGHT<br />

High overload Low overload FR/IP W x H x D<br />

P [kW] I(H) I(overload) P [kW] I(L) [mm] [kg]<br />

NXC15006A2L0TSFA1A2+ODU+ICB+AMO+TUP 1300 1300 1950 1500 1500 FR14/IP21 2806x2275x605 2250<br />

NXC15006A5L0TSFA1A2+ODU+ICB+AMO+TUP 1300 1300 1950 1500 1500 FR14/IP54 2806x2405x605 2280<br />

+ODU (du/dt filter), +ICB (MCCB), +AMO (ICB motor operator), +TUP INCLUDED AS STANDARD *<br />

I(H) = nominal current for 150% overload requirement (at max. 40°C ambient temperature)<br />

I(L) = nominal current for 110% overload requirement (at max. 40°C ambient temperature)<br />

I(overload) = maximum 1 min/10 min overload current (high overload)<br />

Vacon NXC Options DESCRIPTION NOTE<br />

+ACH Cabinet heater 50 W 1 x 50 W, requires +TUP *<br />

+ACL Cabinet light Requires +TUP *<br />

+CIT Cabling Input Top Including +CIT/+COT (W:+400 mm)<br />

+DCM Analog meter + curr.trafo CT on L1<br />

+DVM Analog V-meter + sel.sw. For main voltages<br />

+GPL 100 mm base/plinth For basic drive **<br />

+OCM Common mode chokes To be put on motor cable<br />

+OSI Sine wave filter *** W: +2x800 mm<br />

* IF UNIT ORDERED WITHOUT CONTROL VOLTAGE TRANSFORMER (ATx), THIS OPTION REQUIRES EXTERNAL 230 V SUPPLY<br />

** NOTE THAT THE OPTIONS THAT AFFECTS ON THE WIDHT OF THE CABINET REQUIRES AN EXTRA +GPL (see NXC common options on page 87)<br />

***PLEASE CHECK THE AVAILABILITY FROM THE FACTORY<br />

Vacon NXC 525-690 V, 1500 A, EMC level T, air-cooled AC drive, 12-pulse supply<br />

The prices are the same as L level ones.<br />

Replace the L by T in the order typecode.<br />

SUBJECT TO CHANGE WITHOUT NOTICE<br />

Vacon Plc Runsorintie 7 65380 VAASA FINLAND tel.:+358-201-2121 fax: +358 (0)201 212 205 http://www.vacon.com 99


Vacon Plc<br />

AC drive<br />

VACON PLC<br />

Vacon NXC 525-690 V, 1900 A, EMC level L, air-cooled AC drive, 12-pulse supply<br />

ORDER TYPE CODE MOTOR SHAFT POWER AND CURRENT SIZE/PROT. DIMENSIONS WEIGHT<br />

High overload Low overload FR/IP W x H x D<br />

P [kW] I(H) I(overload) P [kW] I(L) [mm] [kg]<br />

NXC19006A2L0TSFA1A2+ODU+ICB+AMO+TUP 1500 1500 2250 1800 1900 FR14/IP21 2806x2275x605 2250<br />

NXC19006A5L0TSFA1A2+ODU+ICB+AMO+TUP 1500 1500 2250 1800 1900 FR14/IP54 2806x2405x605 2280<br />

+ODU (du/dt filter), +ICB (MCCB), +AMO (ICB motor operator), +TUP INCLUDED AS STANDARD *<br />

I(H) = nominal current for 150% overload requirement (at max. 40°C ambient temperature)<br />

I(L) = nominal current for 110% overload requirement (at max. 40°C ambient temperature)<br />

I(overload) = maximum 1 min/10 min overload current (high overload)<br />

Vacon NXC Options DESCRIPTION NOTE<br />

+ACH Cabinet heater 50 W 1 x 50 W, requires +TUP *<br />

+ACL Cabinet light Requires +TUP *<br />

+CIT Cabling Input Top Including +CIT/+COT (W:+400 mm)<br />

+DCM Analog meter + curr.trafo CT on L1<br />

+DVM Analog V-meter + sel.sw. For main voltages<br />

+GPL 100 mm base/plinth For basic drive **<br />

+OCM Common mode chokes To be put on motor cable<br />

+OSI Sine wave filter *** W: +2x800 mm<br />

* IF UNIT ORDERED WITHOUT CONTROL VOLTAGE TRANSFORMER (ATx), THIS OPTION REQUIRES EXTERNAL 230 V SUPPLY<br />

** NOTE THAT THE OPTIONS THAT AFFECTS ON THE WIDHT OF THE CABINET REQUIRES AN EXTRA +GPL (see NXC common options on page 87)<br />

***PLEASE CHECK THE AVAILABILITY FROM THE FACTORY<br />

Vacon NXC 525-690 V, 1900 A, EMC level T, air-cooled AC drive, 12-pulse supply<br />

The prices are the same as L level ones.<br />

Replace the L by T in the order typecode.<br />

SUBJECT TO CHANGE WITHOUT NOTICE<br />

Vacon Plc Runsorintie 7 65380 VAASA FINLAND tel.:+358-201-2121 fax: +358 (0)201 212 205 http://www.vacon.com 100


Vacon Plc<br />

AC drive<br />

VACON PLC<br />

Vacon NXC 525-690 V, 2250 A, EMC level L, air-cooled AC drive, 12-pulse supply<br />

ORDER TYPE CODE MOTOR SHAFT POWER AND CURRENT SIZE/PROT. DIMENSIONS WEIGHT<br />

High overload Low overload FR/IP W x H x D<br />

P [kW] I(H) I(overload) P [kW] I(L) [mm] [kg]<br />

NXC22506A2L0TSFA1A2+ODU+ICB+AMO+TUP* 1800 1900 2782 2000 2250 FR14/IP21 2806x2275x605 2300<br />

NXC22506A5L0TSFA1A2+ODU+ICB+AMO+TUP* 1800 1900 2782 2000 2250 FR14/IP54 2806x2405x605 2330<br />

+ODU (du/dt filter), +ICB (MCCB), +AMO (ICB motor operator), +TUP INCLUDED AS STANDARD **<br />

* max. 35 C ambient temperature<br />

I(H) = nominal current for 150% overload requirement (at max. 40°C ambient temperature)<br />

I(L) = nominal current for 110% overload requirement (at max. 40°C ambient temperature)<br />

I(overload) = maximum 1 min/10 min overload current (high overload)<br />

Vacon NXC Options DESCRIPTION NOTE<br />

+ACH Cabinet heater 50 W 1 x 50 W, requires +TUP **<br />

+ACL Cabinet light Requires +TUP **<br />

+CIT Cabling Input Top Including +CIT/+COT (W:+400 mm)<br />

+DCM Analog meter + curr.trafo CT on L1<br />

+DVM Analog V-meter + sel.sw. For main voltages<br />

+GPL 100 mm base/plinth For basic drive ***<br />

+OCM Common mode chokes To be put on motor cable<br />

+OSI Sine wave filter **** W: +2x800 mm<br />

** IF UNIT ORDERED WITHOUT CONTROL VOLTAGE TRANSFORMER (ATx), THIS OPTION REQUIRES EXTERNAL 230 V SUPPLY<br />

*** NOTE THAT THE OPTIONS THAT AFFECTS ON THE WIDHT OF THE CABINET REQUIRES AN EXTRA +GPL (see NXC common options on page 87)<br />

****PLEASE CHECK THE AVAILABILITY FROM THE FACTORY<br />

Vacon NXC 525-690 V, 2250 A, EMC level T, air-cooled AC drive, 12-pulse supply<br />

The prices are the same as L level ones.<br />

Replace the L by T in the order typecode.<br />

SUBJECT TO CHANGE WITHOUT NOTICE<br />

Vacon Plc Runsorintie 7 65380 VAASA FINLAND tel.:+358-201-2121 fax: +358 (0)201 212 205 http://www.vacon.com 101


Vacon Plc<br />

AC drive<br />

VACON PLC<br />

Common Options for Vacon NXC<br />

Auxiliary Equipment (A-Group)<br />

+AAA Aux. contact (for +ATx supervision) Wired to DIN3<br />

+AAC Aux. contact (for +Ixx options) Wired to DIN3, mounted on ICO if ordered, otherwise on other input device<br />

+AAI Analog signal isolator Order: 1st AI1, 2nd AO, 3rd AI2<br />

+ACR Control relay wired to DO1, If > 3pcs then FR13 requires +G40 (widht +400mm) or +CIT/+COT<br />

+ACS 230 VAC customer socket requires +TUP<br />

+ADC Power supply 24 VDC, 2,5 A 24 VDC to control, requires +TUP<br />

+AMB Mech. brake control 400 V, 4 kVA, to RO2, FR13 requires +G40 (widht +400mm) or +CIT/+COT, requires +TUP<br />

+AMF Motor fan control 400 V, 4kVA, to RO1, FR13 requires +G40 (widht +400mm) or +CIT/+COT, requires +TUP<br />

+AMH Motor heater feeder 230 V, 10A, to RO1, requires +TUP<br />

+AT1 Aux.trafo 200 VA 400 V* or 690 V */230 V requires +TUP, not with +ICB or +ICO<br />

+AT2 Aux.trafo 750 VA 400 V* or 690 V* /230 V requires +TUP, AT2 is minimum size for +ICO and +ICB<br />

+AT3 Aux.trafo 2500 VA 400 V* or 690 V* /230 V requires +TUP<br />

+AT4 Aux.trafo 4000 VA 400 V* or 690 V* /230 V requires +TUP and FR13 requires +G40 (widht +400mm) or +CIT/+COT<br />

* If other voltage used please indicate for correct tapping<br />

Door Mounted (D-Group)<br />

+DAM Analog meter (AO1) Wired to AO1<br />

+DAR Potentiometer for ref. Wired to AIN1<br />

+DCO MC operation switch Wired to ICO if mounted, otherwise to Tlx, requires +TUP<br />

+DEP Emergency push button Wired to EMS-relay if mounted, otherwise to Tlx, requires +TUP<br />

+DLD Pilot light (DO1) Wired to DO1<br />

+DLF Pilot light (FLT) Wired to RO2, requires +TUP<br />

+DLR Pilot light (RUN) Wired to RO1, requires +TUP<br />

+DLV Pilot light (control voltage on) Requires +TUP<br />

+DRO Local/Remote op. switch Wired to DIN6, requires Local/Remote Application<br />

+DRP Reset push button Wired to DIN6<br />

External Terminals (T-Group)<br />

+TIO 35 pcs I/O Terminal For A1/A8/A9 and A2/A3/AF boards, not with Bx boards<br />

+TID 70 pcs I/O Terminal For A1/A8/A9 and A2/A3/AF and B1, B2, B4 and B5 boards<br />

+TUP Separate 230 VAC term.<br />

General (G-Group)<br />

+G40 400 mm empty cabinet Empty section<br />

+G60 600 mm empty cabinet Empty section<br />

+G80 800 mm empty cabinet Empty section<br />

+GPL 100 mm base/plinth For each G40/G60/G80, (H: +100 mm)<br />

Protection Devices (P-Group)<br />

+PES Em. stop (cat 0) Not with PED, requires TUP, FR13 requires +G40 (widht +400 mm) or +CIT/+COT<br />

+PED Em. stop (cat 1) Not with PES, requires TUP, FR13 requires +G40 (widht +400 mm) or +CIT/+COT<br />

+PTR Thermistor relay PTB approved, requires +TUP<br />

+PAP Arc protection system Includes two ARC sensors, requires +TUP and FR13 requires +G40 (widht +400 mm) or +CIT/+COT<br />

+PIF Insulation fault sensor For IT networks, requires +TUP and FR13 requires +G40 (widht +400 mm) or +CIT/+COT<br />

Seaworthy packing<br />

FR10<br />

FR11<br />

FR12<br />

FR13<br />

FR14<br />

Price for extra cabin<br />

Price for standard NXC<br />

Price for standard NXC<br />

Price for standard NXC<br />

Price for standard NXC<br />

Price for standard NXC<br />

Added for all options that affects to the widht of the cabin<br />

Control unit enclosure for Vacon NXC<br />

ORDER TYPE CODE SUITABILITY DESCRIPTION<br />

NXC__________N NXC IP54 Control unit enclosure for OPT-AF option board, standard *<br />

NXC__________O NXC IP54 Control unit enclosure for OPT-AF option board, all circuit boards in the unit varnished *<br />

* It is required that the control unit or the whole drive is IP54 when OPT-AF board is used<br />

SUBJECT TO CHANGE WITHOUT NOTICE<br />

Vacon Plc Runsorintie 7 65380 VAASA FINLAND tel.:+358-201-2121 fax: +358 (0)201 212 205 http://www.vacon.com 102


Vacon Plc<br />

AC drive<br />

VACON PLC<br />

Vacon NXP-line 400-500 VAC, IP00, EMC-level N/T, LIQUID COOLED FC, 6-Pulse with AC-Chokes<br />

ORDER TYPE CODE DRIVE OUTPUT MOTOR POWER LOSS SIZE/PROT. DIMENSIONS WEIGHT<br />

Current<br />

Apparent power kVA **Motor shaft power c/a/T*) CH/IP W x H x D kg<br />

Thermal Rated Rated 400Vac 500Vac 400Vac 500Vac [kW]<br />

ITH IL IH IL IL Ith / IL Ith / IL<br />

[A] [A] [A] [kVA] [kVA] [kW] [kW]<br />

NXP00165A0N1SWSA1A2 16 15 11 10 12 8,3 / 7,5 10 / 9 0,4/0,2/0,6 CH3/IP00 160x431x240 30<br />

NXP00225A0N1SWSA1A2 22 20 15 13 16 11 / 10 14 / 12 0,5/0,2/0,7 CH3/IP00 160x431x240 30<br />

NXP00315A0N1SWSA1A2 31 28 21 18 23 16 / 14 20 / 18 0,7/0,2/0,9 CH3/IP00 160x431x240 30<br />

NXP00385A0N1SWSA1A2 38 35 25 23 29 20 / 18 24 / 22 0,8/0,2/1,0 CH3/IP00 160x431x240 30<br />

NXP00455A0N1SWSA1A2 45 41 30 27 34 23 / 21 29 / 26 1,0/0,3/1,3 CH3/IP00 160x431x240 30<br />

NXP00615A0N1SWSA1A2 61 55 41 36 45 32 / 29 39 / 36 1,3/0,3/1,5 CH3/IP00 160x431x240 30<br />

NXP00725A0N0SWSA1A2 72 65 48 43 53 37 / 34 46 / 42 1,2/0,3/1,5 CH4/IP00 190x493x258 35<br />

NXP00875A0N0SWSA1A2 87 79 58 52 65 45 / 41 56 / 51 1,5/0,3/1,8 CH4/IP00 190x493x258 35<br />

NXP01055A0N0SWSA1A2 105 95 70 63 78 55 / 50 68 / 62 1,8/0,3/2,1 CH4/IP00 190x493x258 35<br />

NXP01405A0N0SWSA1A2 140 127 93 84 104 73 / 66 90 / 82 2,3/0,3/2,6 CH4/IP00 190x493x258 35<br />

NXP01685A0N0SWSA1A2 168 153 112 101 126 87 / 75 110 / 90 4,0/0,4/4,4 CH5/IP00 246x553x264 40<br />

NXP02055A0N0SWSA1A2 205 186 137 122 153 110 / 90 125 / 110 5,0/0,5/5,5 CH5/IP00 246x553x264 40<br />

NXP02615A0N0SWSA1A2 261 237 174 156 195 125 / 110 175 / 150 6,0/0,5/6,5 CH5/IP00 246x553x264 40<br />

NXP03005A0N0SWFA1A2 300 273 200 180 225 150 / 125 200 / 175 7,0/0,6/7,6 CH61/IP00 246x658x374 55<br />

NXP03855A0N0SWFA1A2 385 350 257 230 288 200 / 175 250 / 225 9,0/0,7/9,7 CH61/IP00 246x658x374 55<br />

NXP04605A0N0SWFA1A2 460 418 307 275 344 225 / 200 300 / 275 6,5/0,5/7,0 CH72/IP00 246x1076x372 90<br />

NXP05205A0N0SWFA1A2 520 473 347 311 389 275 / 225 325 / 300 7,5/0,6/8,1 CH72/IP00 246x1076x372 90<br />

NXP05905A0N0SWFA1A2 590 536 393 353 441 300 / 275 375 / 350 9,0/0,7/9,7 CH72/IP00 246x1076x372 90<br />

NXP06505A0N0SWFA1A2 650 591 433 389 486 325 / 300 425 / 375 10,0/0,7/10,7 CH72/IP00 246x1076x372 90<br />

NXP07305A0N0SWFA1A2 730 664 487 437 546 375 / 325 475 / 425 12,0/0,8/12,8 CH72/IP00 246x1076x372 90<br />

NXP08205A0N0SWFA1A2 820 745 547 490 613 425 / 375 525 / 475 12,5/0,8/13,3 CH63/IP00 492x658x380 120<br />

NXP09205A0N0SWFA1A2 920 836 613 550 688 475 / 425 600 / 525 14,4/0,9/15,3 CH63/IP00 492x658x380 120<br />

NXP10305A0N0SWFA1A2 1030 936 687 616 770 525 / 475 650 / 600 16,5/1,0/17,5 CH63/IP00 492x658x380 120<br />

NXP11505A0N0SWFA1A2 1150 1045 767 688 860 600 / 525 750 / 675 18,5/1,0/18,8 CH63/IP00 492x658x380 120<br />

NXP13705A0N0SWFA1A2 1370 1245 913 819 1024 700 / 625 875 / 800 19,0/1,2/20,2 CH74/IP00 746x1124x370 280<br />

NXP16405A0N0SWFA1A2 1640 1491 1093 981 1227 850 / 775 1050 / 950 24,0/1,4/25,4 CH74/IP00 746x1124x370 280<br />

NXP20605A0N0SWFA1A2 2060 1873 1373 1233 1541 1050 / 950 1325 / 1200 32,5/1,8/34,3 CH74/IP00 746x1124x370 280<br />

NXP23005A0N0SWFA1A2 2300 2091 1533 1376 1720 1200 / 1075 1475 / 1350 36,3/2,0/38,3 CH74/IP00 746x1124x370 280<br />

NXP24705A0N0SWFA1A2 2470 2245 1647 1478 1847 1275 / 1150 1600 / 1450 38,8/2,2/41,0 2xCH74/IP00 2x(746x1124x370) 560<br />

NXP29505A0N0SWFA1A2 2950 2681 1967 1765 2206 1525 / 1375 1900 / 1725 46,3/2,6/48,9 2xCH74/IP00 2x(746x1124x370) 560<br />

NXP37105A0N0SWFA1A2 3710 3372 2473 2219 2774 1925 / 1750 2400 / 2175 58,2/3,0/61,2 2xCH74/IP00 2x(746x1124x370) 560<br />

NXP41405A0N0SWFA1A2 4140 3763 2760 2477 3096 2150 / 1950 2650 / 2425 65,0/3,6/68,6 2xCH74/IP00 2x(746x1124x370) 560<br />

** kW VALUES WITH MOTOR PARAMETERS Cosf=0,83 and EFFICIENCY= 95 %<br />

*) C = POWER LOSS INTO COOLANT, A = POWER LOSS INTO AIR, T = TOTAL POWER LOSS.<br />

IF SOME OTHER MAINS VOLTAGE IS USED, APPLY THE FORMULA P = √( 3 x Un x I L) TO CALCULATE THE NX LIQUID COOLED DRIVE OUTPUT APPARENT POWER [kVA].<br />

THE ENCLOSURE CLASS FOR ALL NX LIQUID COOLED AC driveS IS IP00.<br />

SUBJECT TO CHANGE WITHOUT NOTICE<br />

Vacon Plc Runsorintie 7 65380 VAASA FINLAND tel.:+358-201-2121 fax: +358 (0)201 212 205 http://www.vacon.com #


Vacon Plc<br />

AC drive<br />

VACON PLC<br />

Vacon NXP-line 400-500 VAC, IP00, EMC-level N/T, LIQUID COOLED FC, 12-Pulse with AC-Chokes<br />

ORDER TYPE CODE DRIVE OUTPUT MOTOR POWER LOSS SIZE/PROT. DIMENSIONS WEIGHT<br />

Current<br />

Apparent power kVA **Motor shaft power c/a/T*) CH/IP W x H x D kg<br />

Thermal Rated Rated 400Vac 500Vac 400Vac 500Vac [kW]<br />

I TH I L I H I L I L I th / I L I th / I L<br />

[A] [A] [A] [kVA] [kVA] [kW] [kW]<br />

NXP04605A0N0TWFA1A2 460 418 307 275 344 225 / 200 300 / 275 6,5/0,5/7,0 CH72/IP00 246x1076x372 90<br />

NXP05205A0N0TWFA1A2 520 473 347 311 389 275 / 225 325 / 300 7,5/0,6/8,1 CH72/IP00 246x1076x372 90<br />

NXP05905A0N0TWFA1A2 590 536 393 353 441 300 / 275 375 / 350 9,0/0,7/9,7 CH72/IP00 246x1076x372 90<br />

NXP06505A0N0TWFA1A2 650 591 433 389 486 325 / 300 425 / 375 10,0/0,7/10,7 CH72/IP00 246x1076x372 90<br />

NXP07305A0N0TWFA1A2 730 664 487 437 546 375 / 325 475 / 425 12,0/0,8/12,8 CH72/IP00 246x1076x372 90<br />

NXP13705A0N0TWFA1A2 1370 1245 913 819 1024 700 / 625 875 / 800 19,0/1,2/20,2 CH74/IP00 746x1124x370 280<br />

NXP16405A0N0TWFA1A2 1640 1491 1093 981 1227 850 / 775 1050 / 950 24,0/1,4/25,4 CH74/IP00 746x1124x370 280<br />

NXP20605A0N0TWFA1A2 2060 1873 1373 1233 1541 1050 / 950 1325 / 1200 32,5/1,8/34,3 CH74/IP00 746x1124x370 280<br />

NXP24705A0N0TWFA1A2 2470 2245 1647 1478 1847 1275 / 1150 1600 / 1450 38,8/2,2/41,0 2xCH74/IP00 2x(746x1124x370) 560<br />

NXP29505A0N0TWFA1A2 2950 2681 1967 1765 2206 1525 / 1375 1900 / 1725 46,3/2,6/48,9 2xCH74/IP00 2x(746x1124x370) 560<br />

NXP37105A0N0TWFA1A2 3710 3372 2473 2219 2774 1925 / 1750 2400 / 2175 58,2/3,0/61,2 2xCH74/IP00 2x(746x1124x370) 560<br />

NXP41405A0N0TWFA1A2 4140 3763 2760 2477 3096 2150 / 1950 2650 / 2425 65,0/3,6/68,6 2xCH74/IP00 2x(746x1124x370) 560<br />

** kW VALUES WITH MOTOR PARAMETERS Cosf=0,83 and EFFICIENCY= 95 %<br />

*) C = POWER LOSS INTO COOLANT, A = POWER LOSS INTO AIR, T = TOTAL POWER LOSS.<br />

IF SOME OTHER MAINS VOLTAGE IS USED, APPLY THE FORMULA P = √( 3 x Un x I L) TO CALCULATE THE NX LIQUID COOLED DRIVE OUTPUT APPARENT POWER [kVA].<br />

THE ENCLOSURE CLASS FOR ALL NX LIQUID COOLED AC driveS IS IP00.<br />

SUBJECT TO CHANGE WITHOUT NOTICE<br />

Vacon Plc Runsorintie 7 65380 VAASA FINLAND tel.:+358-201-2121 fax: +358 (0)201 212 205 http://www.vacon.com #


Vacon Plc<br />

AC drive<br />

VACON PLC<br />

Vacon NXP-line 465-800 VDC, IP00, EMC-level T, LIQUID COOLED INVERTER<br />

ORDER TYPE CODE DRIVE OUTPUT MOTOR POWER LOSS SIZE/PROT. DIMENSIONS WEIGHT<br />

Current<br />

Apparent power kVA **Motor shaft power c/a/T*) CH/IP W x H x D kg<br />

Thermal Rated Rated 540Vdc 675Vdc 540Vdc 675Vdc [kW]<br />

I TH I L I H I L I L I th / I L I th / I L<br />

[A] [A] [A] [kVA] [kVA] [kW] [kW]<br />

NXP00165A0T1IWSA1A2 16 15 11 10 12 8,3 / 7,5 10 / 9 0,4/10,2/0,6 CH3/IP00 160x431x244 30<br />

NXP00225A0T1IWSA1A2 22 20 15 13 16 11 / 10 14 / 12 0,5/0,2/0,7 CH3/IP00 160x431x244 30<br />

NXP00315A0T1IWSA1A2 31 28 21 18 23 16 / 14 20 / 18 0,7/0,2/0,9 CH3/IP00 160x431x244 30<br />

NXP00385A0T1IWSA1A2 38 35 25 23 29 20 / 18 24 / 22 0,8/0,2/1,0 CH3/IP00 160x431x244 30<br />

NXP00455A0T1IWSA1A2 45 41 30 27 34 23 / 21 29 / 26 1,0/0,3/1,3 CH3/IP00 160x431x244 30<br />

NXP00615A0T1IWSA1A2 61 55 41 36 45 32 / 29 39 / 36 1,3/0,3/1,5 CH3/IP00 160x431x244 30<br />

NXP00725A0T0IWSA1A2 72 65 48 43 53 37 / 34 46 / 42 1,2/0,3/1,5 CH4/IP00 208x493x258 35<br />

NXP00875A0T0IWSA1A2 87 79 58 52 65 45 / 41 56 / 51 1,5/0,3/1,8 CH4/IP00 208x493x258 35<br />

NXP01055A0T0IWSA1A2 105 95 70 63 78 55 / 50 68 / 62 1,8/0,3/2,1 CH4/IP00 208x493x258 35<br />

NXP01405A0T0IWSA1A2 140 127 93 84 104 73 / 66 90 / 82 2,3/0,3/2,6 CH4/IP00 208x493x258 35<br />

NXP01685A0T0IWSA1A2 168 153 112 101 126 87 / 75 110 / 90 2,5/0,3/2,8 CH5/IP00 246x553x264 40<br />

NXP02055A0T0IWSA1A2 205 186 137 122 153 110 / 90 125 / 110 3,0/0,4/3,4 CH5/IP00 246x553x264 40<br />

NXP02615A0T0IWSA1A2 261 237 174 156 195 125 / 110 175 / 150 4,0/0,4/4,4 CH5/IP00 246x553x264 40<br />

NXP03005A0T0IWFA1A2 300 273 200 180 225 150 / 125 200 / 175 4,5/0,4/4,9 CH61/IP00 246x553x232 55<br />

NXP03855A0T0IWFA1A2 385 350 257 230 288 200 / 175 250 / 225 5,5/0,5/6,0 CH61/IP00 246x658x374 55<br />

NXP04605A0T0IWFA1A2 460 418 307 275 344 225 / 200 300 / 275 5,5/0,5/6,0 CH62/IP00 246x658x374 55<br />

NXP05205A0T0IWFA1A2 520 473 347 311 389 275 / 225 325 / 300 6,5/0,5/7,0 CH62/IP00 246x658x374 55<br />

NXP05905A0T0IWFA1A2 590 536 393 353 441 300 / 275 375 / 350 7,5/0,6/8,1 CH62/IP00 246x658x374 55<br />

NXP06505A0T0IWFA1A2 650 591 433 389 486 325 / 300 425 / 375 8,5/0,6/9,1 CH62/IP00 246x658x374 55<br />

NXP07305A0T0IWFA1A2 730 664 487 437 546 375 / 325 475 / 425 10,0/0,7/10,7 CH62/IP00 246x658x374 55<br />

NXP08205A0T0IWFA1A2 820 745 547 490 613 425 / 375 525 / 475 10,0/0,7/10,7 CH63/IP00 492x658x380 120<br />

NXP09205A0T0IWFA1A2 920 836 613 550 688 475 / 425 600 / 525 12,4/0,8/12,4 CH63/IP00 492x658x380 120<br />

NXP10305A0T0IWFA1A2 1030 936 687 616 770 525 / 475 650 / 600 13,5/0,9/14,4 CH63/IP00 492x658x380 120<br />

NXP11505A0T0IWFA1A2 1150 1045 767 688 860 600 / 525 750 / 675 16,0/1,0/17,0 CH63/IP00 492x658x380 120<br />

NXP13705A0T0IWFA1A2 1370 1245 913 819 1024 700 / 625 875 / 800 15,5/1,0/16,5 CH64/IP00 738x658x374 180<br />

NXP16405A0T0IWFA1A2 1640 1491 1093 981 1227 850 / 775 1050 / 950 19,5/1,2/20,7 CH64/IP00 738x658x374 180<br />

NXP20605A0T0IWFA1A2 2060 1873 1373 1233 1541 1050 / 950 1325 / 1200 26,5/1,5/28,0 CH64/IP00 738x658x374 180<br />

NXP23005A0T0IWFA1A2 2300 2091 1533 1376 1720 1200 / 1075 1475 / 1350 34,0/1,8/35,8 CH64/IP00 738x658x374 180<br />

NXP24705A0N0IWFA1A2 2470 2245 1647 1478 1847 1275 / 1150 1600 / 1450 36,0/2,0/38,0 2xCH64/IP00 2x(738x658x374) 360<br />

NXP29505A0N0IWFA1A2 2950 2681 1967 1765 2206 1525 / 1375 1900 / 1725 39,0/2,4/41,4 2xCH64/IP00 2x(738x658x374) 360<br />

NXP37105A0N0IWFA1A2 3710 3372 2473 2219 2774 1925 / 1750 2400 / 2175 48,0/2,7/50,7 2xCH64/IP00 2x(738x658x374) 360<br />

NXP41405A0N0IWFA1A2 4140 3763 2760 2477 3096 2150 / 1950 2650 / 2425 53,0/3,0/66,0 2xCH64/IP00 2x(738x658x374) 360<br />

** kW VALUES WITH MOTOR PARAMETERS Cosf=0,83 and EFFICIENCY= 95 %<br />

*) C = POWER LOSS INTO COOLANT, A = POWER LOSS INTO AIR, T = TOTAL POWER LOSS.<br />

IF SOME OTHER MAINS VOLTAGE IS USED, APPLY THE FORMULA DC<br />

P = (Un/1,35)* √(3 * l L) TO CALCULATE THE NX LIQUID COOLED DRIVE ELECTRICAL OUTPUT APPARENT POWER [kVA].<br />

THE VOLTAGE CLASSES FOR THE INVERTER UNITS USED IN THE TABLES ABOVE HAVE BEEN DEFINED AS FOLLOWS:'<br />

INPUT 540VDC = RECTIFIED 400VAC SUPPLY<br />

INPUT 675VDC = RECTIFIED 500VAC SUPPLY<br />

THE ENCLOSURE CLASS FOR ALL NX LIQUID COOLED AC driveS IS IP00.<br />

SUBJECT TO CHANGE WITHOUT NOTICE<br />

Vacon Plc Runsorintie 7 65380 VAASA FINLAND tel.:+358-201-2121 fax: +358 (0)201 212 205 http://www.vacon.com #


Vacon Plc<br />

AC drive<br />

VACON PLC<br />

Vacon NXP-line 525-690 VAC, IP00, EMC-level N/T, LIQUID COOLED FC, 6-Pulse with AC-Chokes<br />

ORDER TYPE CODE DRIVE OUTPUT MOTOR POWER LOSS SIZE/PROT. DIMENSIONS WEIGHT<br />

Current<br />

Apparent power kVA **Motor shaft power c/a/T*) CH/IP W x H x D kg<br />

Thermal Rated Rated 525Vac 690Vac 525Vac 690Vac [kW]<br />

I TH I L I H I L I L I th / I L I th / I L<br />

[A] [A] [A] [kVA] [kVA] [kW] [kW]<br />

NXP01706A0T0SWFA1A2 170 155 113 141 185 110 / 100 150 / 125 7,5/0,4/7,9 CH61/IP00 246X658X374 55<br />

NXP02086A0T0SWFA1A2 208 189 139 172 226 140 / 125 175 / 150 9,0/0,5/9,5 CH61/IP00 246X658X374 55<br />

NXP02616A0T0SWFA1A2 261 237 174 216 284 175 / 160 225 / 200 6,5/0,3/6,8 CH61/IP00 246X1076X372 90<br />

NXP03256A0T0SWFA1A2 325 295 217 269 353 225 / 200 275 / 250 7,5/0,4/7,9 CH72/IP00 246X1076X373 90<br />

NXP03856A0T0SWFA1A2 385 350 257 318 418 250 / 225 350 / 300 9,0/0,5/9,5 CH72/IP00 246X1076X374 90<br />

NXP04166A0T0SWFA1A2 416 378 277 344 452 275 / 250 375 / 325 9,4/0,5/9,9 CH72/IP00 246X1076X375 90<br />

NXP04606A0T0SWFA1A2 460 418 307 380 500 315 / 275 400 / 350 10,0/0,5/10,5 CH72/IP00 246X1076X376 90<br />

NXP05026A0T0SWFA1A2 502 456 335 415 545 325 / 300 450 / 400 12,0/0,6/12,6 CH72/IP00 246X1076X377 90<br />

NXP05906A0T0SWFA1A2 590 536 393 488 641 400 / 350 525 / 475 13,0/0,7/13,7 CH63/IP00 492X658X380 120<br />

NXP06506A0T0SWFA1A2 650 591 433 537 706 450 / 400 575 / 525 16,0/0,8/16,8 CH63/IP00 492X658X380 120<br />

NXP07506A0T0SWFA1A2 750 682 500 620 815 500 / 450 675 / 600 18,0/0,9/18,9 CH63/IP00 492X658X380 120<br />

NXP08206A0T0SWFA1A2 820 745 547 678 891 550 / 500 725 / 650 19,0/1,0/20,0 CH74/IP00 746X1124X370 280<br />

NXP09206A0T0SWFA1A2 920 836 613 761 1000 625 / 575 825 / 750 20,0/1,0/21,4 CH74/IP00 746X1124X370 280<br />

NXP10306A0T0SWFA1A2 1030 936 687 851 1119 700 / 625 925 / 825 22,0/1,1/23,1 CH74/IP00 746X1124X370 280<br />

NXP11806A0T0SWFA1A2 1180 1073 787 975 1282 800 / 725 1050 / 950 25,0/1,3/26,3 CH74/IP00 746X1124X370 280<br />

NXP13006A0T0SWFA1A2 1300 1182 867 1075 1412 875 / 800 1150 / 1050 31,0/1,6/32,6 CH74/IP00 746X1124X370 280<br />

NXP15006A0T0SWFA1A2 1500 1364 1000 1240 1630 1000 / 925 1350 / 1225 38,0/1,9/39,9 CH74/IP00 746X1124X370 280<br />

NXP17006A0T0SWFA1A2 1700 1545 1133 1405 1847 1100 / 1000 1500 / 1375 38,0/1,9/39,9 CH74/IP00 746X1124X370 280<br />

NXP18506A0T0SWFA1A2 1850 1682 1233 1529 2010 1250 / 1150 1650 / 1500 39,6/2,0/41,6 2xCH74/IP00 2x(746X1124X370) 560<br />

NXP21206A0T0SWFA1A2 2120 1927 1413 1753 2303 1420 / 1300 1900 / 1725 45,0/2,4/47,4 2xCH74/IP00 2x(746X1124X370) 560<br />

NXP23406A0T0SWFA1A2 2340 2127 1560 1934 2542 1575 / 1450 2100 / 1900 55,8/2,9/58,7 2xCH74/IP00 2x(746X1124X370) 560<br />

NXP27006A0T0SWFA1A2 2700 2455 1800 2232 2933 1825 / 1675 2400 / 2200 68,4/3,4/71,8 2xCH74/IP00 2x(746X1124X370) 560<br />

NXP31006A0T0SWFA1A2 3100 2818 2067 2563 3368 2075 / 1925 2750 / 2500 68,4/3,4/71,8 2xCH74/IP00 2x(746X1124X370) 560<br />

Vacon NXP-line 525-690 VAC, IP00, EMC-level N/T, LIQUID COOLED FC, 12-Pulse with AC-Chokes<br />

ORDER TYPE CODE DRIVE OUTPUT MOTOR POWER LOSS SIZE/PROT. DIMENSIONS WEIGHT<br />

Current Apparent power kVA **Motor shaft power c/a/T*) CH/IP W x H x D kg<br />

Thermal Rated Rated 525Vac 690Vac 525Vac 690Vac [kW]<br />

I TH I L I H I L I L I th / I L I th / I L<br />

[A] [A] [A] [kVA] [kVA] [kW] [kW]<br />

NXP03256A0T0TWFA1A2 325 295 217 269 353 225 / 200 275 / 250 7,5/0,4/7,9 CH72/IP00 246X1076X373 90<br />

NXP03856A0T0TWFA1A2 385 350 257 318 418 250 / 225 350 / 300 9,0/0,5/9,5 CH72/IP00 246X1076X374 90<br />

NXP04166A0T0TWFA1A2 416 378 277 344 452 275 / 250 375 / 325 9,4/0,5/9,9 CH72/IP00 246X1076X375 90<br />

NXP04606A0T0TWFA1A2 460 418 307 380 500 315 / 275 400 / 350 10,0/0,5/10,5 CH72/IP00 246X1076X376 90<br />

NXP05026A0T0TWFA1A2 502 456 335 415 545 325 / 300 450 / 400 12,0/0,6/12,6 CH72/IP00 246X1076X377 90<br />

NXP08206A0T0TWFA1A2 820 745 547 678 891 550 / 500 725 / 650 19,0/1,0/20,0 CH74/IP00 746X1124X370 280<br />

NXP09206A0T0TWFA1A2 920 836 613 761 1000 625 / 575 825 / 750 20,0/1,0/21,4 CH74/IP00 746X1124X370 280<br />

NXP10306A0T0TWFA1A2 1030 936 687 851 1119 700 / 625 925 / 825 22,0/1,1/23,1 CH74/IP00 746X1124X370 280<br />

NXP11806A0T0TWFA1A2 1180 1073 787 975 1282 800 / 725 1050 / 950 25,0/1,3/26,3 CH74/IP00 746X1124X370 280<br />

NXP13006A0T0TWFA1A2 1300 1182 867 1075 1412 875 / 800 1150 / 1050 31,0/1,6/32,6 CH74/IP00 746X1124X370 280<br />

NXP15006A0T0TWFA1A2 1500 1364 1000 1240 1630 1000 / 925 1350 / 1225 38,0/1,9/39,9 CH74/IP00 746X1124X370 280<br />

NXP17006A0T0TWFA1A2 1700 1545 1133 1405 1847 1100 / 1000 1500 / 1375 38,0/1,9/39,9 CH74/IP00 746X1124X370 280<br />

NXP18506A0T0TWFA1A2 1850 1682 1233 1529 2010 1250 / 1150 1650 / 1500 39,6/2,0/41,6 2xCH74/IP00 2x(746X1124X370) 560<br />

NXP21206A0T0TWFA1A2 2120 1927 1413 1753 2303 1420 / 1300 1900 / 1725 45,0/2,4/47,4 2xCH74/IP00 2x(746X1124X370) 560<br />

NXP23406A0T0TWFA1A2 2340 2127 1560 1934 2542 1575 / 1450 2100 / 1900 55,8/2,9/58,7 2xCH74/IP00 2x(746X1124X370) 560<br />

NXP27006A0T0TWFA1A2 2700 2455 1800 2232 2933 1825 / 1675 2400 / 2200 68,4/3,4/71,8 2xCH74/IP00 2x(746X1124X370) 560<br />

NXP31006A0T0TWFA1A2 3100 2818 2067 2563 3368 2075 / 1925 2750 / 2500 68,4/3,4/71,8 2xCH74/IP00 2x(746X1124X370) 560<br />

** kW VALUES WITH MOTOR PARAMETERS Cosf=0,83 and EFFICIENCY= 95 % *) C = POWER LOSS INTO COOLANT, A = POWER LOSS INTO AIR, T = TOTAL POWER LOSS.<br />

IF SOME OTHER MAINS VOLTAGE IS USED, APPLY THE FORMULA P = √( 3 x Un x I L) TO CALCULATE THE NX LIQUID COOLED DRIVE OUTPUT APPARENT POWER [kVA].<br />

THE ENCLOSURE CLASS FOR ALL NX LIQUID COOLED AC driveS IS IP00.<br />

SUBJECT TO CHANGE WITHOUT NOTICE<br />

Vacon Plc Runsorintie 7 65380 VAASA FINLAND tel.:+358-201-2121 fax: +358 (0)201 212 205 http://www.vacon.com #


Vacon Plc<br />

AC drive<br />

VACON PLC<br />

Vacon NXP-line 640-1100 VDC, IP00, EMC-level T, LIQUID COOLED INVERTER<br />

ORDER TYPE CODE DRIVE OUTPUT MOTOR POWER LOSS SIZE/PROT. DIMENSIONS WEIGHT<br />

Current<br />

Apparent power kVA **Motor shaft power c/a/T*) CH/IP W x H x D kg<br />

Thermal Rated Rated 640Vdc 930Vdc 640Vdc 930Vdc [kW]<br />

I TH I L I H I L I L I th / I L I th / I L<br />

[A] [A] [A] [kVA] [kVA] [kW] [kW]<br />

NXP01706A0T0IWFA1A2 170 155 113 141 185 110 / 100 150 / 125 4,5/0,2/4,7 CH61/IP00 246X658X374 55<br />

NXP02086A0T0IWFA1A2 208 189 139 172 226 140 / 125 175 / 150 5,5/0,3/5,8 CH61/IP00 246X658X374 55<br />

NXP02616A0T0IWFA1A2 261 237 174 216 283 175 / 160 225 / 200 5,5/0,3/5,8 CH61/IP00 246X658X374 55<br />

NXP03256A0T0IWFA1A2 325 295 217 268 353 225 / 200 275 / 250 6,5/0,3/6,8 CH62/IP00 246X658X374 55<br />

NXP03856A0T0IWFA1A2 385 350 257 318 418 250 / 225 350 / 300 7,5/0,4/7,9 CH62/IP00 246X658X374 55<br />

NXP04166A0T0IWFA1A2 416 378 277 344 452 275 / 250 375 / 325 8,1/0,4/8,4 CH62/IP00 246X658X374 55<br />

NXP04606A0T0IWFA1A2 460 418 307 380 500 315 / 275 400 / 350 8,5/0,4/8,9 CH62/IP00 246X658X374 55<br />

NXP05026A0T0IWFA1A2 502 456 335 415 545 325 / 300 450 / 400 10,0/0,5/10,5 CH62/IP00 246X658X374 55<br />

NXP05906A0T0IWFA1A2 590 536 393 487 641 400 / 350 525 / 475 10,0/0,5/10,5 CH63/IP00 492X658X380 120<br />

NXP06506A0T0IWFA1A2 650 591 433 537 706 450 / 400 575 / 525 13,5/0,7/14,2 CH63/IP00 492X658X380 120<br />

NXP07506A0T0IWFA1A2 750 682 500 620 815 500 / 450 675 / 600 16,0/0,8/16,8 CH63/IP00 492X658X380 120<br />

NXP08206A0T0IWFA1A2 820 745 547 677 890 550 / 500 725 / 650 16,0/0,8/16,8 CH64/IP00 738X658X374 180<br />

NXP09206A0T0IWFA1A2 920 836 613 760 999 625 / 575 825 / 750 17,8/1,0/18,4 CH64/IP00 738X658X374 180<br />

NXP10306A0T0IWFA1A2 1030 936 687 851 1119 700 / 625 925 / 825 19,0/1,0/20,0 CH64/IP00 738X658X374 180<br />

NXP11806A0T0IWFA1A2 1180 1073 787 976 1282 800 / 725 1050 / 950 21,0/1,1/22,1 CH64/IP00 738X658X374 180<br />

NXP13006A0T0IWFA1A2 1300 1182 867 1075 1413 875 / 800 1150 / 1050 27,0/1,4/28,4 CH64/IP00 738X658X374 180<br />

NXP15006A0T0IWFA1A2 1500 1364 1000 1240 1630 1000 / 925 1350 / 1225 32,0/1,6/33,6 CH64/IP00 738X658X374 180<br />

NXP17006A0T0IWFA1A2 1700 1545 1133 1405 1847 1100 / 1000 1500 / 1375 38,0/1,9/39,9 CH64/IP00 746X1124X370 280<br />

NXP18506A0T0IWFA1A2 1850 1682 1233 1529 2010 1250 / 1150 1650 / 1500 34,2/1,8/36,0 2xCH64/IP00 2x(738X658X374) 360<br />

NXP21206A0T0IWFA1A2 2120 1927 1413 1753 2303 1420 / 1300 1900 / 1725 37,8/2,0/39,8 2xCH64/IP00 2x(738X658X374) 360<br />

NXP23406A0T0IWFA1A2 2340 2127 1560 1934 2542 1575 / 1450 2100 / 1900 48,6/2,5/51,1 2xCH64/IP00 2x(738X658X374) 360<br />

NXP27006A0T0IWFA1A2 2700 2455 1800 2232 2933 1825 / 1675 2400 / 2200 57,6/3,0/60,6 2xCH64/IP00 2x(738X658X374) 360<br />

NXP31006A0T0IWFA1A2 3100 2818 2067 2563 3368 2075 / 1925 2750 / 2500 68,4/3,4/71,8 2xCH64/IP00 2x(746X1124X370) 560<br />

** kW VALUES WITH MOTOR PARAMETERS Cosf=0,83 and EFFICIENCY= 95 %<br />

*) C = POWER LOSS INTO COOLANT, A = POWER LOSS INTO AIR, T = TOTAL POWER LOSS.<br />

IF SOME OTHER MAINS VOLTAGE IS USED, APPLY THE FORMULA DC<br />

P = (Un/1,35)* √(3 * l L) TO CALCULATE THE NX LIQUID COOLED DRIVE ELECTRICAL OUTPUT APPARENT POWER [kVA].<br />

THE VOLTAGE CLASSES FOR THE INVERTER UNITS USED IN THE TABLES ABOVE HAVE BEEN DEFINED AS FOLLOWS:'<br />

INPUT 640VDC = RECTIFIED 525VAC SUPPLY<br />

INPUT 930VDC = RECTIFIED 690VAC SUPPLY<br />

THE ENCLOSURE CLASS FOR ALL NX LIQUID COOLED AC driveS IS IP00.<br />

SUBJECT TO CHANGE WITHOUT NOTICE<br />

Vacon Plc Runsorintie 7 65380 VAASA FINLAND tel.:+358-201-2121 fax: +358 (0)201 212 205 http://www.vacon.com #


Vacon Plc<br />

AC drive<br />

VACON PLC<br />

Vacon NXB-line 465-800 VDC, IP00, EMC-level T, LIQUID COOLED EXTERNAL BRAKE CHOPPER<br />

ORDER TYPE CODE DRIVE OUTPUT POWER LOSS SIZE/PROT. DIMENSIONS WEIGHT<br />

Current<br />

Electrical braking power c/a/T*) CH/IP W x H x D kg<br />

Thermal Minimum resistance [kW]<br />

I TH @600Vdc@800Vdc @600Vdc @800Vdc<br />

[A] [Ohm] [Ohm] [kW] [kW]<br />

NXB00315A0T0 8WSA1A2 2x 31 19,5 25,7 37 49 0,7/0,2/0,9 CH3/IP00 160x431x244 30<br />

NXB00615A0T0 8WSA1A2 2x 61 9,9 13,1 73 97 1,3/0,3/1,5 CH3/IP00 160x431x244 30<br />

NXB00875A0T0 8WSA1A2 2x 87 7 9,2 105 138 1,5/0,3/1,8 CH4/IP00 208x493x258 35<br />

NXB01055A0T0 8WSA1A2 2x 105 5,8 7,6 127 167 1,8/0,3/2,1 CH4/IP00 208x493x258 35<br />

NXB01405A0T0 8WSA1A2 2x 140 4,3 5,7 169 223 2,3/0,3/2,6 CH4/IP00 208x493x258 35<br />

NXB01685A0T0 8WSA1A2 2x 168 3,6 4,7 203 267 2,5/0,3/2,8 CH5/IP00 246x553x264 40<br />

NXB02055A0T0 8WSA1A2 2x 205 3 3,9 248 326 3,0/0,4/3,4 CH5/IP00 246x553x264 40<br />

NXB02615A0T0 8WSA1A2 2x 261 2,3 3,1 316 415 4,0/0,4/4,4 CH5/IP00 246x553x264 40<br />

NXB03005A0T0 8WFA1A2 2x 300 2 2,7 363 477 4,5/0,4/4,9 CH61/IP00 246x553x232 55<br />

NXB03855A0T0 8WFA1A2 2x 385 1,6 2,1 466 613 5,5/0,5/6,0 CH61/IP00 246x658x374 55<br />

NXB04605A0T0 8WFA1A2 2x 460 1,3 1,7 556 732 5,5/0,5/6,0 CH62/IP00 246x658x374 55<br />

NXB05205A0T0 8WFA1A2 2x 520 1,2 1,5 629 828 6,5/0,5/7,0 CH62/IP00 246x658x374 55<br />

NXB05905A0T0 8WFA1A2 2x 590 1,1 1,4 714 939 7,5/0,6/8,1 CH62/IP00 246x658x374 55<br />

NXB06505A0T0 8WFA1A2 2x 650 1 1,2 786 1035 8,5/0,6/9,1 CH62/IP00 246x658x374 55<br />

NXB07305A0T0 8WFA1A2 2x 730 0,9 1,1 883 1162 10,0/0,7/10,7 CH62/IP00 246x658x374 55<br />

Vacon NXB-line 640-1100 VDC, IP00, EMC-level T, LIQUID COOLED EXTERNAL BRAKE CHOPPER<br />

ORDER TYPE CODE DRIVE OUTPUT POWER LOSS SIZE/PROT. DIMENSIONS WEIGHT<br />

Current<br />

Electrical braking power c/a/T*) CH/IP W x H x D kg<br />

Thermal Minimum resistance [kW]<br />

I TH @840Vdc1100Vdc @840Vdc @1100Vdc<br />

[A] [Ohm] [Ohm] [kW] [kW]<br />

NXB01706A0T0 8WFA1A2 2x 170 4,9 6,5 282 372 4,5/0,2/4,7 CH61/IP00 246X658X374 55<br />

NXB02086A0T0 8WFA1A2 2x 208 4 5,3 346 456 5,5/0,3/5,8 CH61/IP00 246X658X374 55<br />

NXB02616A0T0 8WFA1A2 2x 261 3,2 4,2 435 572 5,5/0,3/5,8 CH61/IP00 246X658X374 55<br />

NXB03256A0T0 8WFA1A2 2x 325 2,6 3,4 542 713 6,5/0,3/6,8 CH62/IP00 246X658X374 55<br />

NXB03856A0T0 8WFA1A2 2x 385 2,2 2,9 643 845 7,5/0,4/7,9 CH62/IP00 246X658X374 55<br />

NXB04166A0T0 8WFA1A2 2x 416 2 2,6 693 913 8,1/0,4/8,4 CH62/IP00 246X658X374 55<br />

NXB04606A0T0 8WFA1A2 2x 460 1,8 2,4 767 1010 8,5/0,4/8,9 CH62/IP00 246X658X374 55<br />

NXB05026A0T0 8WFA1A2 2x 502 1,7 2,2 838 1100 10,0/0,5/10,5 CH62/IP00 246X658X374 55<br />

Note: The rated currents in given ambient temperatures (+50°C) and coolant temperatures (+30°C) are achieved only when the switching frequency<br />

is equal to or less than the factory default.<br />

Note: Braking power; P break = 2 x U 2 break / R break<br />

Note: max input DC-current; I in_max = P break_max / U break<br />

SUBJECT TO CHANGE WITHOUT NOTICE<br />

Vacon Plc Runsorintie 7 65380 VAASA FINLAND tel.:+358-201-2121 fax: +358 (0)201 212 205 http://www.vacon.com #


Vacon Plc<br />

AC drive<br />

VACON PLC<br />

Vacon NXA-line 465-800 VDC, IP00, EMC-level T, LIQUID COOLED ACTIVE FRONT END<br />

ORDER TYPE CODE AFE INPUT AFE OUTPUT to DC-LINK POWER LOSS SIZE/PROT. DIMENSIONS WEIGHT<br />

Current<br />

Apparent power kVA **Dimensioning Powe c/a/T*) CH/IP W x H x D kg<br />

Thermal Rated Rated 594Vdc 742Vdc 594Vdc 742Vdc [kW]<br />

I TH I L I H I L I L I th / I L I th / I L<br />

[A] [A] [A] [kVA] [kVA] [kW] [kW]<br />

NXA01685A0T0IWSA1A2 168 153 112 114 143 125 / 100 150 / 125 2,5/0,3/2,8 CH5/IP00 246x553x264 40<br />

NXA02055A0T0IWSA1A2 205 186 137 139 174 150 / 125 175 / 150 3,0/0,4/3,4 CH5/IP00 246x553x264 40<br />

NXA02615A0T0IWSA1A2 261 237 174 177 221 200 / 175 225 / 200 4,0/0,4/4,4 CH5/IP00 246x553x264 40<br />

NXA03005A0T0IWFA1A2 300 273 200 204 255 225 / 200 275 / 250 4,5/0,4/4,9 CH61/IP00 246x553x232 55<br />

NXA03855A0T0IWFA1A2 385 350 257 261 327 275 / 250 325 / 300 5,5/0,5/6,0 CH61/IP00 246x658x374 55<br />

NXA04605A0T0IWFA1A2 460 418 307 312 390 325 / 300 400 / 375 5,5/0,5/6,0 CH62/IP00 246x658x374 55<br />

NXA05205A0T0SWSA1A2 520 473 347 353 442 375 / 350 475 / 425 6,5/0,5/7,0 CH62/IP00 246x658x374 55<br />

NXA05905A0T0IWFA1A2 590 536 393 400 500 425 / 375 525 / 475 7,5/0,6/8,1 CH62/IP00 246x658x374 55<br />

NXA06505A0T0IWFA1A2 650 591 433 441 552 475 / 425 575 / 525 8,5/0,6/9,1 CH62/IP00 246x658x374 55<br />

NXA07305A0T0IWFA1A2 730 664 487 496 620 525 / 475 650 / 600 10,0/0,7/10,7 CH62/IP00 246x658x374 55<br />

NXA08205A0T0IWFA1A2 820 745 547 556 696 575 / 525 725 / 675 10,0/0,7/10,7 CH63/IP00 492x658x380 120<br />

NXA09205A0T0IWFA1A2 920 836 613 624 780 650 / 600 825 / 750 12,4/0,8/12,4 CH63/IP00 492x658x380 120<br />

NXA10305A0T0IWFA1A2 1030 936 687 699 874 750 / 675 925 / 850 13,5/0,9/14,4 CH63/IP00 492x658x380 120<br />

NXA11505A0T0IWFA1A2 1150 1045 767 780 976 825 / 750 1025 / 950 16,0/1,0/17,0 CH63/IP00 492x658x380 120<br />

NXA13705A0T0IWFA1A2 1370 1245 913 930 1162 975 / 900 1225 / 1125 15,5/1,0/16,5 CH64/IP00 738x658x374 180<br />

NXA16405A0T0IWFA1A2 1640 1491 1093 1114 1392 1200 / 1100 1500 / 1375 19,5/1,2/20,7 CH64/IP00 738x658x374 180<br />

NXA20605A0T0IWFA1A2 2060 1873 1373 1399 1749 1475 / 1350 1850 / 1700 26,5/1,5/28,0 CH64/IP00 738x658x374 180<br />

NXA23005A0T0IWFA1A2 2300 2091 1533 1562 1952 1650 / 1500 2050 / 1900 34,0/1,8/35,8 CH64/IP00 738x658x374 180<br />

Vacon NXA-line 640-1100 VDC, IP00, EMC-level T, LIQUID COOLED ACTIVE FRONT END<br />

ORDER TYPE CODE AFE INPUT AFE OUTPUT to DC-LINK POWER LOSS SIZE/PROT. DIMENSIONS WEIGHT<br />

Current<br />

Apparent power kVA **Dimensioning Powe c/a/T*) CH/IP W x H x D kg<br />

Thermal Rated Rated 780Vdc 1025Vdc 780Vdc 1025Vdc [kW]<br />

I TH I L I H I L I L I th / I L I th / I L<br />

[A] [A] [A] [kVA] [kVA] [kW] [kW]<br />

NXA01706A0T0IWFA1A2 170 155 113 152 200 175 / 150 200 / 175 4,5/0,2/4,7 CH61/IP00 246X658X374 55<br />

NXA02086A0T0IWFA1A2 208 189 139 185 243 200 / 175 250 / 225 5,5/0,3/5,8 CH61/IP00 246X658X374 55<br />

NXA02616A0T0IWFA1A2 261 237 174 232 305 250 / 225 325 / 300 5,5/0,3/5,8 CH61/IP00 246X658X374 55<br />

NXA03256A0T0IWFA1A2 325 295 217 289 380 300 / 275 400 / 375 6,5/0,3/6,8 CH62/IP00 246X658X374 55<br />

NXA03856A0T0IWFA1A2 385 350 257 343 451 350 / 325 475 / 450 7,5/0,4/7,9 CH62/IP00 246X658X374 55<br />

NXA04166A0T0IWFA1A2 416 378 277 371 487 400 / 350 500 / 475 8,1/0,4/8,4 CH62/IP00 246X658X374 55<br />

NXA04606A0T0IWFA1A2 460 418 307 410 539 450 / 400 575 / 525 8,5/0,4/8,9 CH62/IP00 246X658X374 55<br />

NXA05026A0T0IWFA1A2 502 456 335 447 587 475 / 425 625 / 575 10,0/0,5/10,5 CH62/IP00 246X658X374 55<br />

NXA05906A0T0IWFA1A2 590 536 393 525 691 575 / 525 725 / 675 10,0/0,5/10,5 CH63/IP00 492X658X380 120<br />

NXA06506A0T0IWFA1A2 650 591 433 579 761 625 / 575 825 / 750 13,5/0,7/14,2 CH63/IP00 492X658X380 120<br />

NXA07506A0T0IWFA1A2 750 682 500 669 879 700 / 650 675 / 600 16,0/0,8/16,8 CH63/IP00 492X658X380 120<br />

NXA08206A0T0IWFA1A2 820 745 547 730 960 825 / 725 1000 / 925 16,0/0,8/16,8 CH64/IP00 738X658X374 180<br />

NXA09206A0T0IWFA1A2 920 836 613 819 1077 875 / 800 1150 / 1050 17,8/1,0/18,4 CH64/IP00 738X658X374 180<br />

NXA10306A0T0IWFA1A2 1030 936 687 918 1206 975 / 900 1275 / 1150 19,0/1,0/20,0 CH64/IP00 738X658X374 180<br />

NXA11806A0T0IWFA1A2 1180 1073 787 1052 1382 1125 / 1025 1475 / 1350 21,0/1,1/22,1 CH64/IP00 738X658X374 180<br />

NXA13006A0T0IWFA1A2 1300 1182 867 1159 1523 1225 / 1125 1650 / 1500 27,0/1,4/28,4 CH64/IP00 738X658X374 180<br />

NXA15006A0T0IWFA1A2 1500 1364 1000 1337 1757 1450 / 1325 1900 / 1725 32,0/1,6/33,6 CH64/IP00 738X658X374 180<br />

* Switching freq 3,6kHz<br />

** kW/KkVA VALUES WITH INPUT PARAMETERS TPF=0,98, (Note! On AFE DC-supply terminals)<br />

*) C = POWER LOSS INTO COOLANT, A = POWER LOSS INTO AIR, T = TOTAL POWER LOSS.<br />

IF SOME OTHER MAINS VOLTAGE IS USED, APPLY THE FORMULA P = √( 3 x Un x 1,1 x I L) TO CALCULATE THE NX LIQUID COOLED DRIVE OUTPUT APPARENT POWER [kVA].<br />

THE ENCLOSURE CLASS FOR ALL NX LIQUID COOLED AC driveS IS IP00.<br />

SUBJECT TO CHANGE WITHOUT NOTICE<br />

Vacon Plc Runsorintie 7 65380 VAASA FINLAND tel.:+358-201-2121 fax: +358 (0)201 212 205 http://www.vacon.com #


Vacon Plc<br />

AC drive<br />

VACON PLC<br />

VACON NX_OPTIONS Air-Cooled, Naturally convected Regenerative line filters IP00, (LCL)<br />

ORDER TYPE CODE SUITABILITY DESCRIPTION WHD WEIGHT [kg]<br />

REG 410 5 0 P Ch61/500V: 300Aac, 385Aac LCL-filter L1=185kg, L2=62kg<br />

REG 580 5 0 P Ch62/500V: 416Aac, 460Aac, 520Aac LCL-filter L1=195kg, L2=77kg<br />

REG 840 5 0 P Ch62/500V: 590Aac, 650Aac, 730Aac LCL-filter L1=270kg, L2=100kg<br />

REG 1160 5 0 P Ch63/500V: 820...1150Aac LCL-filter L1=390kg, L2=140kg<br />

REG 1480 5 0 P Ch64/500V: 1370Aac LCL-filter L1=470kg, L2=155kg<br />

* L1 AFE side, L2 Grid side Transfer products<br />

VACON NX_OPTIONS Liquid-Cooled Regenerative line filters IP00, (LCL)<br />

ORDER TYPE CODE SUITABILITY DESCRIPTION WHD WEIGHT [kg]<br />

RLC-0385-6-0 Ch62/690V: 325, 385Aac LCL-filter, 2-P<br />

RLC-0520-6-0 Ch62/500-690V LCL-filter, 3-P<br />

RLC-0750-6-0 Ch62/500, Ch63/690V LCL-filter, 3-P<br />

RLC-0920-6-0 Ch63/500, Ch64/690V LCL-filter, 3-P<br />

RLC-1180-6-0 Ch63/500, Ch64/690V LCL-filter, 3-P<br />

RLC-1640-6-0 Ch64/500-690V LCL-filter, 3-P<br />

RLC-2300-5-0 Ch64/500V: 2060, 2300Aac LCL-filter, 2-P<br />

VACON NX_OPTIONS Liquid-Cooled filters<br />

Transfer products<br />

ORDER TYPE CODE SUITABILITY DESCRIPTION WHD WEIGHT [kg]<br />

FER-FGT All Common-mode filter cores D=85mm, l=120mm<br />

mounted on tube<br />

Max cable d=50mm<br />

Transfer products<br />

VACON NX_OPTIONS Pre-Charging Circuit, (Loose components)<br />

ORDER TYPE CODE SUITABILITY DESCRIPTION NOTE<br />

CP01047 All Diode bridge 82/16<br />

PP00066 All Resistor CAV 150C47R<br />

Transfer products<br />

Vacon Liquid Cooled OPTIONS Cooling interface, Spin nuts and fast connectors<br />

ORDER TYPE CODE SUITABILITY DESCRIPTION NOTE<br />

CON-1 CH61, CH62, CH72 Spin nut connection kit, adapter for customer connection 2pc.<br />

CON-2 CH63 Spin nut connection kit, adapter for customer connection 4pc.<br />

CON-3 CH64, CH74 Spin nut connection kit, adapter for customer connection 6pc.<br />

CON-4 CH61, CH62, CH72 TEMA hose kit, Fast connector w anti-dripping valve 2pc.<br />

CON-5 CH63 TEMA hose kit, Fast connector w anti-dripping valve 4pc.<br />

CON-6 CH64, CH74 TEMA hose kit, Fast connector w anti-dripping valve 6pc.<br />

SUBJECT TO CHANGE WITHOUT NOTICE<br />

Vacon Plc Runsorintie 7 65380 VAASA FINLAND tel.:+358-201-2121 fax: +358 (0)201 212 205 http://www.vacon.com #


Vacon Plc<br />

AC drive<br />

VACON PLC<br />

Vacon Liquid Cooled OPTIONS Control - Power unit communication cables<br />

ORDER TYPE CODE SUITABILITY DESCRIPTION NOTE<br />

PP60017 Ch61, Ch62/72, Ch63, Ch64/74 Fiber optic cable set 0,7m<br />

PP60010 Ch61, Ch62/72, Ch63, Ch64/74 Fiber optic cable set 1,5m Standard<br />

PP60016 Ch61, Ch62/72, Ch63, Ch64/74 Fiber optic cable set 3,5m Std when Ch3, Ch4, Ch5 w FIB-1.5<br />

PP13111 Ch61, Ch62/72, Ch63, Ch64/74 Fiber optic cable set 8m<br />

PP12001 2x Ch64/74 Fiber optic cable set 1,8m Power unit 1.<br />

PP12002 2x Ch64/74 Fiber optic cable set 3,8m Power unit 2.<br />

PP13109 2x Ch64/74 Fiber optic cable set 8m Power unit 1.<br />

PP13110 2x Ch64/74 Fiber optic cable set 8m Power unit 2.<br />

PP31001 CH3-CH4 Cable set CU-PU 1,15m<br />

PP51015 CH5 Cable set CU-PU 1,15m<br />

Vacon Liquid Cooled OPTIONS Vaconbus upgrading to fiber optic CH3-CH5<br />

ORDER TYPE CODE SUITABILITY DESCRIPTION NOTE<br />

FIB-1.5 CH3-CH5 Fiber Kit (Boards and cable)<br />

Vacon Liquid Cooled OPTIONS Flow switch<br />

ORDER TYPE CODE SUITABILITY DESCRIPTION NOTE<br />

FW00204 Ch5, Ch6x, Ch7x Flow switch / SIKA VKS 15 M G 1/2", 1pcs Customer cooling system is not<br />

approved by Vacon<br />

transfer products<br />

Vacon Liquid Cooled OPTIONS Cooling Hoses<br />

ORDER TYPE CODE SUITABILITY DESCRIPTION NOTE<br />

Drive end thread<br />

Customer end thread<br />

FW00150 2pcs Lenght 1,5m, indiam. 16mm G3/4" male fixed+Usit-R sealing G1/2" male fixed+Usit-R sealing<br />

FW00151 2pcs Lenght 0,6m, indiam. 19mm G3/4" male fixed+Usit-R sealing G3/4" male fixed+Usit-R sealing<br />

FW00152 2pcs Lenght 1,0m, indiam. 19mm G3/4" male fixed+Usit-R sealing<br />

G3/4" male fixed+Usit-R sealing<br />

FW00157 2pcs Lenght 1,5m, indiam. 19mm G3/4" male fixed+Usit-R sealing<br />

G3/4" female swivel<br />

FW00158, Standard delivery 2pcs Lenght 1,5m, indiam. 16mm Female G1/2" Swivel conical seal G1/2" male fixed+Usit-R sealing<br />

FW00205, Standard delivery 2pcs Al hose adapter 160 x d 32 mm G3/4" male fixed+Usit-R sealing G1/2" male fixed conical sealing<br />

FW00208 2pcs Al hose adapter 160 x d 32 mm G3/4" male fixed+Usit-R sealing G3/4" male fixed conical sealing<br />

*all threads ISO 228-1 transfer products<br />

Vacon Liquid Cooled OPTIONS Varnished PCB's<br />

ORDER TYPE CODE SUITABILITY DESCRIPTION NOTE<br />

NX________xxV Ch3-Ch5 Varnished printed circuit boards Ch3, Ch4, Ch5<br />

NX________xxG or xxV Ch61, Ch62, Ch72 Varnished printed circuit boards Ch61, Ch62, Ch72<br />

NX________xxG or xxV Ch63 Varnished printed circuit boards Ch63<br />

NX________xxG or xxV Ch64, Ch74 Varnished printed circuit boards Ch64, Ch74<br />

NX________xxG or xxV 2xCh64, 2xCh74 Varnished printed circuit boards 2xCh64, 2xCh74<br />

SUBJECT TO CHANGE WITHOUT NOTICE<br />

Vacon Plc Runsorintie 7 65380 VAASA FINLAND tel.:+358-201-2121 fax: +358 (0)201 212 205 http://www.vacon.com #


Vacon Plc<br />

AC drive<br />

VACON PLC<br />

Vacon Liquid Cooled OPTIONS AC-Chokes price reduction<br />

ORDER TYPE CODE SUITABILITY DESCRIPTION NOTE<br />

Ch5 500V 6-P Ch5 500V AC-Chokes price reduction<br />

Ch63 500V 6-P Ch63 500V AC-Chokes price reduction<br />

Ch72 500V 12-P Ch72 500V AC-Chokes price reduction<br />

Ch74 500V 12-P Ch74 500V AC-Chokes price reduction<br />

2x Ch74 500V 12-P 2x Ch74 500V AC-Chokes price reduction<br />

Ch72 690V 12-P Ch72 690V AC-Chokes price reduction<br />

Ch74 690V 12-P Ch74 690V AC-Chokes price reduction<br />

2x Ch74 690V 12-P 2x Ch74 690V AC-Chokes price reduction<br />

Vacon Liquid Cooled OPTIONS Heat exchangers<br />

ORDER TYPE CODE SUITABILITY DESCRIPTION NOTE<br />

HXL-M-040-N-P up to 40kW, 120 l/min IP00 heat exchanger PVC-C piping<br />

HXL-M-120-N-P up to 120kW, 360 l/min IP00 heat exchanger PVC-C piping<br />

HXM-M-120-N-P up to 120kW, 360 l/min IP00 heat exchanger PVC-C piping<br />

HXL-M-120-N-S up to 120kW, 360 l/min IP00 heat exchanger Stainless steel piping<br />

HXL-R-040-N-P up to 40kW, 120 l/min Rittal TS8 Heat exchanger installed into IP54-cabinet IP54<br />

HXL-R-120-N-P up to 120kW, 360 l/min Rittal TS8 Heat exchanger installed into IP54-cabinet IP54<br />

HXM-R-120-N-P up to 120kW, 360 l/min Rittal TS8 Heat exchanger installed into IP54-cabinet IP54<br />

HXL-V-040-N-P up to 40kW, 120 l/min Veda Heat exchanger installed into IP54-cabinet IP54<br />

HXL-V-120-N-P up to 120kW, 360 l/min Veda Heat exchanger installed into IP54-cabinet IP54<br />

HXM-V-120-N-P up to 120kW, 360 l/min Veda Heat exchanger installed into IP54-cabinet IP54<br />

Flanges, Thread pipes, Manifolds, Inhibitors<br />

HXL040-P003-1 Flange (1pcs) for HXL-040 with interface pipe Flange, tube collar, sealing, bolts & nuts DN25 / l=183mm<br />

HX_120-P003-1 FlangeA (1pcs) for HXL-120 with interface pipe Flange, tube collar, sealing, bolts & nuts DN50 / l=194mm<br />

HX_120-P003-2 FlangeB (1pcs) for HXL-120 with interface pipe Flange, tube collar, sealing, bolts & nuts DN50 / l=279mm<br />

HX_120-P003-5 Thread pipe (1pcs) for HXL-120 thread interface Both ends with threads D63mm / l=124mm<br />

HX_-P003-6 In/Out Manifold (1pcs) HXL040&HXL120, DN50 distribution No of interfaces 5pcs, 1/2" thread PVC-C, D63mm / l=700mm<br />

HXL040-P003-3 Thread pipe (1pcs) for HXL-040 thread interface Both ends with threads D63mm/d=32mm l=124mm<br />

MC 01023 Cortec VpCI-649 Inhibitor 1 liter<br />

Vacon Liquid Cooled OPTIONS Water chillers 400-500 VAC<br />

ORDER TYPE CODE SUITABILITY DESCRIPTION NOTE<br />

kW bar l/min<br />

P@35C P@45C p q<br />

UC-0030SP 3,8 3,3 3 20 Water chiller IP44<br />

UC-0080SP 13,7 11,2 3,5 40 Water chiller IP54<br />

UC-0140SP 22,1 18,3 3,5 80 Water chiller IP54<br />

UC-0240SP 41,8 34,2 3 120 Water chiller IP54<br />

UC-0400SP 48,6 - 3,5 120 Water chiller IP54<br />

UC-0800SP 97,2 - 3,5 240 Water chiller IP54<br />

UC-0500SP/E - 43 3,5 120 Water chiller IP54<br />

UC-1000SP/E - 86 3,5 240 Water chiller IP54<br />

transfer products<br />

SUBJECT TO CHANGE WITHOUT NOTICE<br />

Vacon Plc Runsorintie 7 65380 VAASA FINLAND tel.:+358-201-2121 fax: +358 (0)201 212 205 http://www.vacon.com #


Vacon Plc<br />

Frequency Converter<br />

VACON PLC<br />

Vacon NXI-line 380-500 V, IP00, EMC-level T, AIR-COOLED INVERTER UNIT<br />

ORDER TYPE CODE MOTOR CONTINUOUS CURRENT [A] SIZE/PROT. DIMENSIONS WEIGHT<br />

at Low Overload / 40ºC at High Overload / 40ºC FR/IP W x H x D<br />

Motor Motor Motor Motor [mm] [kg]<br />

400VAC 500VAC 400VAC 500VAC<br />

IL [A] Pn [kW] Pn [kW] IH [A] Pn [kW] Pn [kW]<br />

NXI00045A2T0CSSA1A2 4,3 1,5 2,2 3,3 1,1 1,1 FR4/IP21 128x292x190 5<br />

NXI00095A2T0CSSA1A2 9 4 5,5 7,6 3 4 FR4/IP21 128x292x190 5<br />

NXI00125A2T0CSSA1A2 12 5,5 7,5 9 4 5,5 FR4/IP21 128x292x190 5<br />

NXI00165A2T0CSSA1A2 16 7,5 11 12 5,5 7,5 FR6/IP21 195x519x237 16<br />

NXI00225A2T0CSSA1A2 23 11 15 16 7,5 11 FR6/IP21 195x519x237 16<br />

NXI00315A2T0CSSA1A2 31 15 18,5 23 11 15 FR6/IP21 195x519x237 16<br />

NXI00385A2T0CSSA1A2 38 18,5 22 31 15 18,5 FR6/IP21 195x519x237 16<br />

NXI00455A2T0CSSA1A2 46 22 30 38 18,5 22 FR6/IP21 195x519x237 16<br />

NXI00615A2T0CSSA1A2 61 30 37 46 22 30 FR7/IP21 237x591x257 29<br />

NXI00725A2T0CSSA1A2 72 37 45 61 30 37 FR7/IP21 237x591x257 29<br />

NXI00875A2T0CSSA1A2 87 45 55 72 37 45 FR7/IP21 237x591x257 29<br />

NXI01055A2T0CSSA1A2 105 55 75 87 45 55 FR7/IP21 237x591x257 29<br />

NXI01405A0T0CSSA1A2 140 75 90 105 55 75 FR8/IP00 289x758x344 48<br />

NXI01685A0T0ISFA1A2 168 90 110 140 75 90 FI9/IP00 239x1030x372 67<br />

NXI02055A0T0ISFA1A2 205 110 132 170 90 110 FI9/IP00 239x1030x372 67<br />

NXI02615A0T0ISFA1A2 261 132 160 205 110 132 FI9/IP00 239x1030x372 67<br />

NXI03005A0T0ISFA1A2 300 160 200 245 132 160 FI9/IP00 239x1030x372 67<br />

NXI03855A0T0ISFA1A2 385 200 250 300 160 200 FI10/IP00 239x1032x552 100<br />

NXI04605A0T0ISFA1A2 460 250 315 385 200 250 FI10/IP00 239x1032x552 100<br />

NXI05205A0T0ISFA1A2 520 250 355 460 250 315 FI10/IP00 239x1032x552 100<br />

NXI05905A0T0ISFA1A2 590 315 400 520 250 355 FI12/IP00 (2x239)x1032x552 200<br />

NXI06505A0T0ISFA1A2 650 355 450 590 315 400 FI12/IP00 (2x239)x1032x552 200<br />

NXI07305A0T0ISFA1A2 730 400 500 650 355 450 FI12/IP00 (2x239)x1032x552 200<br />

NXI08205A0T0ISFA1A2 820 450 560 730 400 500 FI12/IP00 (2x239)x1032x552 200<br />

NXI09205A0T0ISFA1A2 920 500 630 820 450 560 FI12/IP00 (2x239)x1032x552 200<br />

NXI10305A0T0ISFA1A2 1030 560 710 920 500 630 FI12/IP00 (2x239)x1032x552 200<br />

NXI11505A0T0ISFA1A2 1150 710 900 1150 560 800 FI13/IP00 708x1032x553 306<br />

NXI13005A0T0ISFA1A2 1300 710 900 1150 630 800 FI13/IP00 708x1032x553 306<br />

NXI14505A0T0ISFA1A2 1450 800 1000 1300 710 900 FI13/IP00 708x1032x553 306<br />

NXI17705A0T0ISFA1A2 1770 1000 1200 1600 900 1200 FI14/IP00 (2x708)x1032x553 612<br />

NXI21505A0T0ISFA1A2 2150 1200 1500 1940 1100 1400 FI14/IP00 (2x708)x1032x553 612<br />

NXI27005A0T0ISFA1A2 2700 1500 1800 2300 1500 1800 FI14/IP00 (2x708)x1032x553 612<br />

I(H) = nominal current for 150% overload requirement<br />

(at max. 50°C ambient temperature: FI9 and bigger: at max. 40°C ambient temperature).<br />

I(L) = nominal current for 110% overload requirement (at max. 40°C ambient temperature).<br />

I(overload) = maximum 1 min/10 min overload current (high overload).<br />

SUBJECT TO CHANGE WITHOUT NOTICE<br />

Vacon Plc Runsorintie 7 65380 VAASA FINLAND tel.:+358-201-2121 fax.: +358 (0)201 212 205 http://www.vacon.com 113


Vacon Plc<br />

Frequency Converter<br />

VACON PLC<br />

Vacon NXI-line 525-690 V, IP00, EMC-level T, AIR-COOLED INVERTER UNIT<br />

ORDER TYPE CODE MOTOR CONTINUOUS CURRENT [A] SIZE/PROT. DIMENSIONS WEIGHT<br />

at Low Overload / 40ºC at High Overload / 40ºC FR/IP W x H x D<br />

Motor 690VAC Motor 690VAC [mm] [kg]<br />

IL [A] Pn [kW] IH [A] Pn [kW]<br />

NXI00046A2T0CSSA1A2 4,5 3 3,2 2,2 FR6/IP00 195x519x237 16<br />

NXI00056A2T0CSSA1A2 5,5 4 4,5 3 FR6/IP00 195x519x237 16<br />

NXI00076A2T0CSSA1A2 7,5 5,5 5,5 4 FR6/IP00 195x519x237 16<br />

NXI00106A2T0CSSA1A2 10 7,5 7,5 5,5 FR6/IP00 195x519x237 16<br />

NXI00136A2T0CSSA1A2 13,5 11 10 7,5 FR6/IP00 195x519x237 16<br />

NXI00186A2T0CSSA1A2 18 15 13,5 11 FR6/IP00 195x519x237 16<br />

NXI00226A2T0CSSA1A2 22 18,5 18 15 FR6/IP00 195x519x237 16<br />

NXI00276A2T0CSSA1A2 27 22 22 18,5 FR6/IP00 195x519x237 16<br />

NXI00346A2T0CSSA1A2 34 30 27 22 FR6/IP00 195x519x237 16<br />

NXI00416A0T0CSSA1A2 41 37 34 30 FR7/IP00 237x591x257 29<br />

NXI00526A0T0CSSA1A2 52 45 41 37 FR7/IP00 237x591x257 29<br />

NXI00626A0T0ISFA1A2 62 55 52 45 FR8/IP00 289x758x344 48<br />

NXI00806A0T0ISFA1A2 80 75 62 55 FR8/IP00 289x758x344 48<br />

NXI01006A0T0ISFA1A2 100 90 80 75 FR8/IP00 289x758x344 48<br />

NXI01256A0T0ISFA1A2 125 110 100 90 FI9/IP00 239x1030x372 67<br />

NXI01446A0T0ISFA1A2 144 132 125 110 FI9/IP00 239x1030x372 67<br />

NXI01706A0T0ISFA1A2 170 160 144 132 FI9/IP00 239x1030x372 67<br />

NXI02086A0T0ISFA1A2 208 200 170 160 FI9/IP00 239x1030x372 67<br />

NXI02616A0T0ISFA1A2 261 250 208 200 FI10/IP00 239x1032x552 100<br />

NXI03256A0T0ISFA1A2 325 315 261 250 FI10/IP00 239x1032x552 100<br />

NXI03856A0T0ISFA1A2 385 355 325 315 FI10/IP00 239x1032x552 100<br />

NXI04166A0T0ISFA1A2 416 400 325 315 FI10/IP00 239x1032x552 100<br />

NXI04606A0T0ISFA1A2 460 450 385 355 FI12/IP00 (2x239)x1032x552 200<br />

NXI05026A0T0ISFA1A2 502 500 460 450 FI12/IP00 (2x239)x1032x552 200<br />

NXI05906A0T0ISFA1A2 590 560 502 500 FI12/IP00 (2x239)x1032x552 200<br />

NXI06506A0T0ISFA1A2 650 630 590 560 FI12/IP00 (2x239)x1032x552 200<br />

NXI07506A0T0ISFA1A2 750 710 650 630 FI12/IP00 (2x239)x1032x552 200<br />

NXI08206A0T0ISFA1A2 820 800 650 630 FI12/IP00 (2x239)x1032x552 200<br />

NXI09206A0T0ISFA1A2 920 900 820 800 FI13/IP00 708x1032x553 306<br />

NXI10306A0T0ISFA1A2 1030 1000 920 900 FI13/IP00 708x1032x553 306<br />

NXI11806A0T0ISFA1A2 1180 1150 1030 1000 FI13/IP00 708x1032x553 306<br />

NXI15006A0T0ISFA1A2 1500 1500 1300 1300 FI14/IIP00 (2x708)x1032x553 612<br />

NXI19006A0T0ISFA1A2 1900 1800 1500 1500 FI14/IIP00 (2x708)x1032x553 612<br />

NXI22506A0T0ISFA1A2 2250 2000 1900 1800 FI14/IIP00 (2x708)x1032x553 612<br />

I(H) = nominal current for 150% overload requirement<br />

(at max. 50°C ambient temperature: FI9 and bigger: at max. 40°C ambient temperature).<br />

I(L) = nominal current for 110% overload requirement (at max. 40°C ambient temperature).<br />

I(overload) = maximum 1 min/10 min overload current (high overload).<br />

SUBJECT TO CHANGE WITHOUT NOTICE<br />

Vacon Plc Runsorintie 7 65380 VAASA FINLAND tel.:+358-201-2121 fax.: +358 (0)201 212 205 http://www.vacon.com 114


Vacon Plc<br />

Frequency Converter<br />

VACON PLC<br />

Vacon NXA-line 380-500 V, IP00, EMC-level T, AIR-COOLED ACTIVE FRONT-END (AFE)<br />

ORDER TYPE CODE MAINS CONTINUOUS CURRENT [A] SIZE/PROT. DIMENSIONS WEIGHT<br />

at Low Overload / 40ºC at High Overload / 40ºC FR/IP W x H x D<br />

Motor Motor Motor Motor [mm] [kg]<br />

400VAC 500VAC 400VAC 500VAC<br />

IL [A] Pn [kW] Pn [kW] IH [A] Pn [kW] Pn [kW]<br />

NXA02615A0T02SFA1A2 261 132 160 205 110 132 FI9/IP00 239x1030x372 67<br />

NXA04605A0T02SFA1A2 460 250 315 385 200 250 FI10/IP00 239x1032x552 100<br />

NXA13005A0T02SFA1A2 1300 710 900 1150 630 800 FI13/IP00 708x1032x553 306<br />

Vacon NXA-line 525-690 V, IP00, EMC-level T, AIR-COOLED ACTIVE FRONT-END (AFE)<br />

ORDER TYPE CODE MAINS CONTINUOUS CURRENT [A] SIZE/PROT. DIMENSIONS WEIGHT<br />

at Low Overload / 40ºC at High Overload / 40ºC FR/IP W x H x D<br />

Motor 690VAC Motor 690VAC [mm] [kg]<br />

IL [A] Pn [kW] IH [A] Pn [kW]<br />

NXA01446A0T02SFA1A2 144 132 125 110 FI9/IP00 239x1030x372 67<br />

NXA03256A0T02SFA1A2 325 315 261 250 FI10/IP00 239x1032x552 100<br />

NXA09206A0T02SFA1A2 920 900 820 800 FI13/IP00 708x1032x553 306<br />

I(H) = nominal current for 150% overload requirement<br />

(at max. 50°C ambient temperature: FI9 and bigger: at max. 40°C ambient temperature).<br />

I(L) = nominal current for 110% overload requirement (at max. 40°C ambient temperature).<br />

I(overload) = maximum 1 min/10 min overload current (high overload).<br />

Vacon OPTIONS LCL filter for AIR-COOLED ACTIVE FRONT-END (AFE)<br />

ORDER TYPE CODE<br />

380-500V<br />

Vacon LCL02615A0L011T<br />

Vacon LCL04605A0L011T<br />

Vacon LCL13005A0L011T<br />

525-690V<br />

Vacon LCL01706A0L011T<br />

Vacon LCL03256A0L011T<br />

Vacon LCL10306A0L011T<br />

Vacon Charging Circuit components for NXA and NXF<br />

Charging circuit for FI9<br />

including items: Q'ty Description Product Code<br />

1 Diode Bridge SKD 82<br />

2 Charging resistors CAV150C47R<br />

1 Contactor LC1D32P7<br />

Charging circuit for FI10<br />

including items: Q'ty Description Product Code<br />

1 Diode Bridge SKD 82<br />

2 Charging resistors CAV335C20R<br />

1 Contactor LC1D32P7<br />

Charging circuit for FI13<br />

including items: Q'ty Description Product Code<br />

1 Diode Bridge SKD 82<br />

2 Charging resistors CAV335C11R<br />

1 Contactor LC1D32P7<br />

SUBJECT TO CHANGE WITHOUT NOTICE<br />

Vacon Plc Runsorintie 7 65380 VAASA FINLAND tel.:+358-201-2121 fax.: +358 (0)201 212 205 http://www.vacon.com 115


Vacon Plc<br />

Frequency Converter<br />

VACON PLC<br />

Vacon NXF-line 380-500 V, IP00, EMC-level T, AIR-COOLED FFE UNIT<br />

ORDER TYPE CODE MAINS CONTINUOUS CURRENT [A] SIZE/PROT. DIMENSIONS WEIGHT<br />

at Low Overload / 40ºC at High Overload / 40ºC FR/IP W x H x D<br />

Motor Motor Motor Motor [mm] [kg]<br />

400VAC 500VAC 400VAC 500VAC<br />

IL [A] Pn [kW] Pn [kW] IH [A] Pn [kW] Pn [kW]<br />

NXF03005A0T0ISFA1A2 300 160 200 245 132 160 FI9/IP00 239x1030x372 67<br />

NXF05205A0T0ISFA1A2 520 250 355 460 250 315 FI10/IP00 239x1032x552 100<br />

NXF10305A0T0ISFA1A2 1030 560 710 920 500 630 FI12/IP00 (2x239)x1032x552 200<br />

NXF14505A0T0ISFA1A2 1450 800 1000 1300 710 900 FI13/IP00 708x1032x553 306<br />

NXF27005A0T0ISFA1A2 2700 1500 1800 2300 1500 1800 FI14/IP00 (2x708)x1032x553 612<br />

Vacon NXF-line 625-690 V, IP00, EMC-level T, AIR-COOLED FFE UNIT<br />

Note! FI12 and FI14 requires 12-pulse supply<br />

ORDER TYPE CODE MAINS CONTINUOUS CURRENT [A] SIZE/PROT. DIMENSIONS WEIGHT<br />

at Low Overload / 40ºC at High Overload / 40ºC FR/IP W x H x D<br />

Motor 690VAC Motor 690VAC [mm] [kg]<br />

IL [A] Pn [kW] IH [A] Pn [kW]<br />

NXF02086A0T0ISFA1A2 208 200 170 160 FI9/IP00 239x1030x372 67<br />

NXF04166A0T0ISFA1A2 416 400 325 315 FI10/IP00 239x1032x552 100<br />

NXF08206A0T0ISFA1A2 820 800 650 630 FI12/IP00 (2x239)x1032x552 200<br />

NXF11806A0T0ISFA1A2 1180 1150 1030 1000 FI13/IP00 708x1032x553 306<br />

NXF22506A0T0ISFA1A2 2250 2000 1900 1800 FI14/IIP00 (2x708)x1032x553 612<br />

I(H) = nominal current for 150% overload requirement<br />

(at max. 50°C ambient temperature: FI9 and bigger: at max. 40°C ambient temperature).<br />

I(L) = nominal current for 110% overload requirement (at max. 40°C ambient temperature).<br />

I(overload) = maximum 1 min/10 min overload current (high overload).<br />

Note! FI12 and FI14 requires 12-pulse supply<br />

Vacon NXN-line 625-690 V, IP00, EMC-level T, AIR-COOLED NFE UNIT<br />

ORDER TYPE CODE MAINS CONTINUOUS CURRENT [A] SIZE/PROT. DIMENSIONS WEIGHT<br />

at Low Overload / 40ºC at High Overload / 40ºC FR/IP W x H x D<br />

Motor Motor Motor Motor [mm] [kg]<br />

400VAC 500VAC 400VAC 500VAC<br />

IL [A] Pn [kW] Pn [kW] IH [A] Pn [kW] Pn [kW]<br />

NXN06505B0T0NSS0000 650 355 450 590 315 400 FI12/IP00 (2x239)x1032x552 200<br />

ORDER TYPE CODE MAINS CONTINUOUS CURRENT [A] SIZE/PROT. DIMENSIONS WEIGHT<br />

at Low Overload / 40ºC at High Overload / 40ºC FR/IP W x H x D<br />

Motor 690VAC Motor 690VAC [mm] [kg]<br />

IL [A] Pn [kW] IH [A] Pn [kW]<br />

NXN06506B0T0NSS0000 650 630 590 560 FI12/IP00 (2x239)x1032x552 200<br />

SUBJECT TO CHANGE WITHOUT NOTICE<br />

Vacon Plc Runsorintie 7 65380 VAASA FINLAND tel.:+358-201-2121 fax.: +358 (0)201 212 205 http://www.vacon.com 116


Vacon Plc<br />

Frequency Converter<br />

VACON PLC<br />

Vacon NXB-line 380-500 V, IP00, EMC-level T, AIR-COOLED BRAKE CHOPPER UNIT<br />

ORDER TYPE CODE CONTINUOUS BRAKING CURRENT [A] SIZE/PROT. DIMENSIONS WEIGHT<br />

at Low Overload / 40ºC at High Overload / 40ºC FR/IP W x H x D<br />

Motor Motor Motor Motor [mm] [kg]<br />

400VAC 500VAC 400VAC 500VAC<br />

IL [A] Pn [kW] Pn [kW] IH [A] Pn [kW] Pn [kW]<br />

NXB00045A2T0CSSA1A2 4,3 1,5 2,2 3,3 1,1 1,1 FR4/IP21 128x292x190 5<br />

NXB00095A2T0CSSA1A2 9 4 5,5 7,6 3 4 FR4/IP21 128x292x190 5<br />

NXB00125A2T0CSSA1A2 12 5,5 7,5 9 4 5,5 FR4/IP21 128x292x190 5<br />

NXB00165A2T0CSSA1A2 16 7,5 11 12 5,5 7,5 FR6/IP21 195x519x237 16<br />

NXB00225A2T0CSSA1A2 23 11 15 16 7,5 11 FR6/IP21 195x519x237 16<br />

NXB00315A2T0CSSA1A2 31 15 18,5 23 11 15 FR6/IP21 195x519x237 16<br />

NXB00385A2T0CSSA1A2 38 18,5 22 31 15 18,5 FR6/IP21 195x519x237 16<br />

NXB00455A2T0CSSA1A2 46 22 30 38 18,5 22 FR6/IP21 195x519x237 16<br />

NXB00615A2T0CSSA1A2 61 30 37 46 22 30 FR7/IP21 237x591x257 29<br />

NXB00725A2T0CSSA1A2 72 37 45 61 30 37 FR7/IP21 237x591x257 29<br />

NXB00875A2T0CSSA1A2 87 45 55 72 37 45 FR7/IP21 237x591x257 29<br />

NXB01055A2T0CSSA1A2 105 55 75 87 45 55 FR7/IP21 237x591x257 29<br />

NXB01405A0T0CSSA1A2 140 75 90 105 55 75 FR8/IP00 289x758x344 48<br />

NXB01685A0T0ISFA1A2 168 90 110 140 75 90 FI9/IP00 239x1030x372 67<br />

NXB02055A0T0ISFA1A2 205 110 132 170 90 110 FI9/IP00 239x1030x372 67<br />

NXB02615A0T0ISFA1A2 261 132 160 205 110 132 FI9/IP00 239x1030x372 67<br />

NXB03005A0T0ISFA1A2 300 160 200 245 132 160 FI9/IP00 239x1030x372 67<br />

NXB03855A0T0ISFA1A2 385 200 250 300 160 200 FI10/IP00 239x1032x552 100<br />

NXB04605A0T0ISFA1A2 460 250 315 385 200 250 FI10/IP00 239x1032x552 100<br />

NXB05205A0T0ISFA1A2 520 250 355 460 250 315 FI10/IP00 239x1032x552 100<br />

NXB11505A0T0ISFA1A2 1150 710 900 1150 560 800 FI13/IP00 708x1032x553 306<br />

NXB13005A0T0ISFA1A2 1300 710 900 1150 630 800 FI13/IP00 708x1032x553 306<br />

NXB14505A0T0ISFA1A2 1450 800 1000 1300 710 900 FI13/IP00 708x1032x553 306<br />

I(H) = nominal current for 150% overload requirement<br />

(at max. 50°C ambient temperature: FI9 and bigger: at max. 40°C ambient temperature).<br />

I(L) = nominal current for 110% overload requirement (at max. 40°C ambient temperature).<br />

I(overload) = maximum 1 min/10 min overload current (high overload).<br />

SUBJECT TO CHANGE WITHOUT NOTICE<br />

Vacon Plc Runsorintie 7 65380 VAASA FINLAND tel.:+358-201-2121 fax.: +358 (0)201 212 205 http://www.vacon.com 117


Vacon Plc<br />

Frequency Converter<br />

VACON PLC<br />

Vacon NXB-line 525-690 V, IP00, EMC-level T, AIR-COOLED BRAKE CHOPPER UNIT<br />

ORDER TYPE CODE CONTINUOUS BRAKING CURRENT [A] SIZE/PROT. DIMENSIONS WEIGHT<br />

at Low Overload / 40ºC at High Overload / 40ºC FR/IP W x H x D<br />

Motor 690VAC Motor 690VAC [mm] [kg]<br />

IL [A] Pn [kW] IH [A] Pn [kW]<br />

NXB00046A2T0CSSA1A2 4,5 3 3,2 2,2 FR6/IP00 195x519x237 16<br />

NXB00056A2T0CSSA1A2 5,5 4 4,5 3 FR6/IP00 195x519x237 16<br />

NXB00076A2T0CSSA1A2 7,5 5,5 5,5 4 FR6/IP00 195x519x237 16<br />

NXB00106A2T0CSSA1A2 10 7,5 7,5 5,5 FR6/IP00 195x519x237 16<br />

NXB00136A2T0CSSA1A2 13,5 11 10 7,5 FR6/IP00 195x519x237 16<br />

NXB00186A2T0CSSA1A2 18 15 13,5 11 FR6/IP00 195x519x237 16<br />

NXB00226A2T0CSSA1A2 22 18,5 18 15 FR6/IP00 195x519x237 16<br />

NXB00276A2T0CSSA1A2 27 22 22 18,5 FR6/IP00 195x519x237 16<br />

NXB00346A2T0CSSA1A2 34 30 27 22 FR6/IP00 195x519x237 16<br />

NXB00416A0T0CSSA1A2 41 37 34 30 FR7/IP00 237x591x257 29<br />

NXB00526A0T0CSSA1A2 52 45 41 37 FR7/IP00 237x591x257 29<br />

NXB00626A0T0ISFA1A2 62 55 52 45 FR8/IP00 289x758x344 48<br />

NXB00806A0T0ISFA1A2 80 75 62 55 FR8/IP00 289x758x344 48<br />

NXB01006A0T0ISFA1A2 100 90 80 75 FR8/IP00 289x758x344 48<br />

NXB01256A0T0ISFA1A2 125 110 100 90 FI9/IP00 239x1030x372 67<br />

NXB01446A0T0ISFA1A2 144 132 125 110 FI9/IP00 239x1030x372 67<br />

NXB01706A0T0ISFA1A2 170 160 144 132 FI9/IP00 239x1030x372 67<br />

NXB02086A0T0ISFA1A2 208 200 170 160 FI9/IP00 239x1030x372 67<br />

NXB02616A0T0ISFA1A2 261 250 208 200 FI10/IP00 239x1032x552 100<br />

NXB03256A0T0ISFA1A2 325 315 261 250 FI10/IP00 239x1032x552 100<br />

NXB03856A0T0ISFA1A2 385 355 325 315 FI10/IP00 239x1032x552 100<br />

NXB04166A0T0ISFA1A2 416 400 325 315 FI10/IP00 239x1032x552 100<br />

NXB09206A0T0ISFA1A2 920 900 820 800 FI13/IP00 708x1032x553 306<br />

NXB10306A0T0ISFA1A2 1030 1000 920 900 FI13/IP00 708x1032x553 306<br />

NXB11806A0T0ISFA1A2 1180 1150 1030 1000 FI13/IP00 708x1032x553 306<br />

I(H) = nominal current for 150% overload requirement<br />

(at max. 50°C ambient temperature: FI9 and bigger: at max. 40°C ambient temperature).<br />

I(L) = nominal current for 110% overload requirement (at max. 40°C ambient temperature).<br />

I(overload) = maximum 1 min/10 min overload current (high overload).<br />

SUBJECT TO CHANGE WITHOUT NOTICE<br />

Vacon Plc Runsorintie 7 65380 VAASA FINLAND tel.:+358-201-2121 fax.: +358 (0)201 212 205 http://www.vacon.com 118


Type Designation Code for Vacon NXL MF2-MF3<br />

SUBJECT TO CHANGE WITHOUT NOTICE<br />

Vacon Plc Runsorintie 7 65380 VAASA FINLAND tel.:+358-201-2121 fax: +358 (0)201 212 205 http://www.vacon.com 119


Type Designation Code for Vacon NXL MF4 - MF6<br />

SUBJECT TO CHANGE WITHOUT NOTICE<br />

Vacon Plc Runsorintie 7 65380 VAASA FINLAND tel.:+358-201-2121 fax: +358 (0)201 212 205 http://www.vacon.com 120


Type Designation Code for Vacon NXS and NXP FR4-FR9<br />

NXS 0000 5 A 2 H 1 SSS A1A2000000<br />

Option boards; each slot is represented by two characters where:<br />

Ax = basic I/O board, Bx = expander I/O board<br />

Cx = fieldbus board, Dx = special board<br />

Hardware modifications<br />

SSS = 6-pulse connection; air-cooled; standard board<br />

SSV = 6-pulse connection; air-cooled; varnished board<br />

BSS = Additional DC-connection; air-cooled; standard board (>FR7)<br />

BSV = Additional DC-connection; air-cooled; varnished board (>FR7)<br />

SSF = 6-pulse connection; air-cooled; standard board (FR9)<br />

SSG = 6-pulse connection; air-cooled; varnished board (FR9)<br />

BSF = Additional DC-connection; air-cooled; standard board (FR9)<br />

BSG = Additional DC-connection; air-cooled; varnished board (FR9)<br />

Brake chopper<br />

0 = No brake chopper<br />

1 = Internal brake chopper<br />

2 = Internal brake chopper and resistor (FR4-FR6)<br />

EMC emission level<br />

H = Fulfils standard EN61800-3+A11, 1st environment restricted<br />

distribution, 2nd environment<br />

L = Fulfils standard EN61800-3+A11, 2nd environment, restr. distr.<br />

T = Fulfils standard EN61800-3 for IT Networks<br />

N = No EMC emission protection<br />

C= Fullfills standard EN61800-3+A11, 1st environment unrestricted<br />

distribution (exeption: Radiated emission of the IP21 units<br />

meet only the requirements of restricted distribution), 2nd environment<br />

Enclosure class<br />

0 = IP00 (FR9 only)<br />

2 = IP21 (Nema 1)<br />

5 = IP54 (Nema 12)<br />

Control keypad<br />

A = Standard (alpha-numeric)<br />

B = No local keypad<br />

F = Dummy keypad<br />

G = Graphic display<br />

Nominal mains voltage<br />

2 = 208-240 V, 5 = 380-500 V, 6 = 525-690 V (3 phase)<br />

Nominal current (low overload)<br />

0003 = 3 A etc.<br />

Product range: NXS = Standard, NXP = High-performance<br />

SUBJECT TO CHANGE WITHOUT NOTICE<br />

Vacon Plc Runsorintie 7 65380 VAASA FINLAND tel.:+358-201-2121 fax: +358 (0)201 212 205 http://www.vacon.com 121


Type Designation Code for Vacon NXP and NXC FR9-FR14<br />

NXP 0000 5 A 3 L 0 SSF A1A2000000<br />

Option boards; each slot is represented by two characters where:<br />

Ax = basic I/O board, Bx = expander I/O board<br />

Cx = fieldbus board, Dx = special board<br />

NXC variations:<br />

SSF = Standard<br />

SSG = Varnished boards<br />

TSF = 12-pulse, standard<br />

TSG = 12-pulse, Varnished PCB's<br />

NXP variations:<br />

SSA = Integrated control part, Standard<br />

SSB = Integrated control part, Varnished PCB's<br />

TSA = 12-pulse, integrated control part, Standard<br />

TSA = 12-pulse, integrated control part, Varnished PCB's<br />

Brake chopper<br />

0 = No brake chopper<br />

1 = Integrated brake chopper<br />

EMC emission level<br />

L = Fulfils standard EN61800-3+A11, 2nd environment, restr. distr.<br />

T = Fulfils standard EN61800-3 for IT Networks<br />

N = No EMC emission protection<br />

Enclosure class<br />

0 = IP00 (module only)<br />

2 = IP21 (Nema 1)<br />

5 = IP54 (Nema 12)<br />

Control keypad<br />

A = Standard (alpha-numeric), in Vacon NXC on the cabinet door<br />

B = No local keypad<br />

F = Dummy keypad, in Vacon NXC on the cabinet door<br />

G = Graphic display, in Vacon NXC on the cabinet door<br />

Nominal mains voltage<br />

5 = 380-500 V, 6 = 525-690 V (3 phase)<br />

Nominal current (low overload)<br />

e.g. 0520 = 520 A<br />

Product range:<br />

NXP = Standalone/IP00 module<br />

NXC = Cabinet<br />

SUBJECT TO CHANGE WITHOUT NOTICE<br />

Vacon Plc Runsorintie 7 65380 VAASA FINLAND tel.:+358-201-2121 fax: +358-201-2121-205 www.vacon.com 122


Type designation code for liquid cooled AC drives and inverters<br />

SUBJECT TO CHANGE WITHOUT NOTICE<br />

Vacon Plc Runsorintie 7 65380 VAASA FINLAND tel.:+358-201-2121 fax: +358 (0)201 212 205 http://www.vacon.com 123


Vacon Plc<br />

AC drive<br />

Type designation code for Vacon Heat Exchangers<br />

SUBJECT TO CHANGE WITHOUT NOTICE<br />

Vacon Plc Runsorintie 7 65380 VAASA FINLAND tel.:+358-201-2121 fax: +358 (0)201 212 205 http://www.vacon.com 124


Vacon C'n DC bus products - Type Code key<br />

NX I AAAA V A 2 T 0 C S S A1 A2 00 00 00<br />

Option boards; each slot is represented by two characters where:<br />

A = basic I/O board<br />

B = expander I/O board<br />

C = fieldbus board<br />

D = special board<br />

Hardware modifications; module type - S - Boards<br />

S = Direct connection, standard boards, FR4...8<br />

V = Direct connection, varnished boards, FR4...8<br />

F = Fiber connection, standard boards<br />

G = Fiber connection, varnished boards<br />

S = Standard air cooled drive<br />

A = Standard air cooled power unit - transformer supply for main fan<br />

U = Standard air cooled power unit - external supply for main fan<br />

C = INU - with integrated charging circuit<br />

I = INU - no charging circuit<br />

2 = AFE module<br />

5 = AFE module + LCL filter<br />

3 = FFE module<br />

6 = FFE module + AC choke<br />

4 = NFE module<br />

7 = NFE module + AC choke<br />

8 = BCU Brake chopper unit<br />

0 = N/A (no brake chopper)<br />

EMC emission level;<br />

T = IT networks (EN61800-3)<br />

Enclosure class<br />

2 = IP21, FR4...7<br />

0 = IP00, FR8, FI9...14<br />

Control keypad<br />

A = standard (alpha numeric)<br />

B = no local control keypad<br />

F = dummy keypad<br />

G = graphic display<br />

Nominal supply voltage<br />

5 = 380...500VAC / 465...800VDC<br />

6 = 525...690VAC / 640...1100VDC<br />

Nominal current (low overload)<br />

0004 = 4A, 0520 = 520A, etc.<br />

Module type<br />

A = AFE Active Front End<br />

B = BCU Brake Chopper Unit<br />

F = FFE Fundamental Front End<br />

I = INU Inverter<br />

N = Non regenerative Front End<br />

Product generation<br />

Input Device Options (I group)<br />

+ILS Load Switch<br />

+IFD Switch fuse and fuses<br />

+ICB Circuit Breaker (MCCB)<br />

+ICO Input Contactor<br />

+IFU Input fuses<br />

Charging Options (C group)<br />

+CPF Charging package for Ftont End (contactor, 2pcs resistors and diode bridge)<br />

+CPI Charging package for Inverter (fuse switch, fuses, 2pcs resistors)<br />

Output Filter Options (O group)<br />

+OCM Common mode filters<br />

+ODU dU/dt filter<br />

+OSI Sinusoidal filter<br />

Fuse Options (F group)<br />

+FDA DC fuses for Front End<br />

+FDI DC fuses for INU<br />

SUBJECT TO CHANGE WITHOUT NOTICE<br />

125


Vacon LCL filters - Type code<br />

Type code<br />

Product range<br />

Current<br />

Voltage<br />

Versio<br />

IP class<br />

HF capacitors<br />

Capacitor<br />

balancing<br />

Reserve<br />

Manufacturer<br />

Standard<br />

Module<br />

Vacon LCL AAAA V A 0 L 0 1 0 T<br />

Types available Vacon LCL 0460 5 A 0 L 0 1 1 T<br />

Vacon LCL 1300 5 A 0 L 0 1 1 T<br />

Vacon LCL 0325 6 A 0 L 0 1 1 T<br />

Vacon LCL 1030 6 A 0 L 0 1 1 T<br />

Manufacturer<br />

T = Trafotek<br />

LCL cooling fan<br />

0 = AC fan<br />

1 = DC fan<br />

Balancing resistors<br />

1 = on HF capacitors<br />

0 = No resistors (IT networks)<br />

Main Capacitor variant<br />

0 = As specified<br />

No variation at the moment<br />

HF capacitors<br />

L = Mounted (á 25 uF)<br />

0 = No capacitors<br />

IP Class<br />

0 = IP00<br />

Version (Hardware)<br />

A = Released 24.04.2006<br />

(460/325)<br />

Voltage<br />

5 = 380...500VAC<br />

6 = 525...690 VAC<br />

Current<br />

0460 = 460A<br />

0385 = 385A, etc<br />

Product range<br />

LCL = LCL filter for AFE<br />

SUBJECT TO CHANGE WITHOUT NOTICE<br />

Vacon Plc Runsorintie 7 65380 VAASA FINLAND tel.:+358-201-2121 fax: +358 (0)201 212 205 http://www.vacon.com 126